WorldWideScience

Sample records for inverted takotsubo pattern

  1. Adderall induced inverted-Takotsubo cardiomyopathy.

    Science.gov (United States)

    Alsidawi, Said; Muth, James; Wilkin, James

    2011-11-15

    Takotsubo Cardiomyopathy (TTC), also known as stress-induced cardiomyopathy, was initially described in Japan in 1990. Both illicit and prescription drugs have added to the growing list of insulting stressors. We describe an interesting case of atypical TTC triggered by adderall overdose. A 19-year-old female was brought to the Emergency Department after ingesting 30 Adderall tablets. She was complaining of pressure like chest pain and shortness of breath. Her cardiac enzymes were elevated but the electrocardiogram was unremarkable. Echocardiography identified an ejection fraction (EF) of 25-30% with severe hypokinesis of the base and a preserved apex. Cardiac angiography demonstrated normal coronary arteries with an EF of 35%, hyperkinetic apex and akinetic base consistent with the diagnosis of inverted-TTC. Her symptoms resolved in 24 hrs. Repeat echocardiogram performed 3 days later showed an EF of 60% with no regional wall motion abnormalities. TTC can be identified as a rapid development of severe and reversible left ventricular dysfunction extending beyond the territory of a single epicardial coronary artery in the absence of coronary artery disease or pheochromocytoma. Clinical presentation can be challenging and very hard to distinguish from acute myocardial infarction. Medication induced-TTC has been reported. In our case, the patient overdosed on Adderall which is a sympathomimetic medication. Cardiac imaging identified wall motion abnormalities consistent with inverted type TTC. Restoration of left ventricular function within days confirms the diagnosis of TTC. In conclusion, this case offers an interesting insight into the pathophysiology of TTC. Copyright © 2011 Wiley Periodicals, Inc.

  2. Cardiogenic Shock due to Psychosis-Induced Inverted Takotsubo Cardiomyopathy Bridged-to-Recovery with a Percutaneous Left Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Ravi Korabathina

    2016-01-01

    Full Text Available Inverted Takotsubo cardiomyopathy, a less common variant in the spectrum of stress-induced cardiomyopathy, is increasingly being reported. This report describes an acute psychiatric illness leading to the onset of this syndrome. The patient presented here developed cardiogenic shock but successfully recovered with the use of a percutaneous left ventricular assist device.

  3. Inverted Takotsubo-Like Left Ventricular Dysfunction with Pulmonary Oedema Developed after Caesarean Delivery Complicated by Massive Haemorrhage in a Severe Preeclamptic Parturient with a Prolonged Painful Labour

    Directory of Open Access Journals (Sweden)

    Hyejin Jeong

    2011-01-01

    Full Text Available Inverted takotsubo cardiomyopathy (TTC, a variant of stress-induced cardiomyopathy, features transient myocardial dysfunction characterized by a hyperdynamic left ventricular apex and akinesia of the base. Herein, we describe a 38-year-old primigravida with severe preeclampsia who had active labour for 4 h followed by an emergency caesarean delivery. She developed postpartum haemorrhage due to uterine atony complicated by pulmonary oedema, which was managed with large-volume infusion and hysterectomy. Her haemodynamic instability was associated with cardiac biomarkers indicative of diffuse myocardial injury and echocardiographic findings of an “inverted” TTC. The patient was almost fully recovered one month later. Our case shows that a reversible inverted TTC may result from a prolonged painful labour. TTC should be listed in the differential diagnosis of the patient presenting with pulmonary oedema of unknown origin, especially in patients with severe preeclampsia.

  4. Takotsubo (Stress) Cardiomyopathy

    Science.gov (United States)

    ... the American Heart Association Cardiology Patient Page Takotsubo (Stress) Cardiomyopathy Scott W. Sharkey , John R. Lesser , Barry ... heart contraction has returned to normal. Importance of Stress In 85% of cases, takotsubo is triggered by ...

  5. Behavioural Pattern of Invertibility Parameter of Arima Model ...

    African Journals Online (AJOL)

    It was deduced that behaviour of invertibility parameter πidepends on the order of autoregressive part (p), the order of integrated part (d), positive and negative values of moving average parameter (ϑ). Journal of the Nigerian Association of Mathematical Physics, Volume 19 (November, 2011), pp 591 – 606 ...

  6. Inferior ST-Elevation Myocardial Infarction Associated with Takotsubo Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Oliver Koeth

    2010-01-01

    Full Text Available Takotsubo cardiomyopathy (TCM is usually characterized by transient left ventricular apical ballooning. Due to the clinical symptoms which include chest pain, electrocardiographic changes, and elevated myocardial markers, Takotsubo cardiomyopathy is frequently mimicking ST-elevation myocardial infarction in the absence of a significant coronary artery disease. Otherwise an acute occlusion of the left anterior descending coronary artery can produce a typical Takotsubo contraction pattern. ST-elevation myocardial infarction (STEMI is frequently associated with emotional stress, but to date no cases of STEMI triggering TCM have been reported. We describe a case of a female patient with inferior ST-elevation myocardial infarction complicated by TCM.

  7. Bladder tumours in children: An interesting case report of TCC with a partial inverted growth pattern.

    Science.gov (United States)

    El Rahman, Davide Abed; Salvo, Giuseppe; Palumbo, Carlotta; Rocco, Bernardo; Rocco, Francesco

    2014-09-30

    Bladder urothelial carcinoma is typically a disease of older individuals and rarely occurs below the age of 40 years. There is debate and uncertainty in the literature regarding the clinicopathologic and prognostic characteristics of bladder urothelial neoplasms in younger patients compared with older patients, although no consistent age criteria have been used to define "younger" age group categories. We report on a 16 years old girl with transitional cell carcinoma of the bladder with a partial inverted growth pattern who presented with gross hematuria. Ultrasonography revealed a papillary lesion in the bladder; cystoscopic evaluation showed a 15 mm papillary lesion with a thick stalk located in the left bladder wall. Pathologic evaluation of the specimen was reported as "low grade transitional cell carcinoma of the bladder with a partial inverted growth pattern".

  8. Transient left atrial dysfunction is a feature of Takotsubo syndrome

    DEFF Research Database (Denmark)

    Stiermaier, Thomas; Graf, Tobias; Möller, Christian

    2017-01-01

    BACKGROUND: Takotsubo syndrome (TTS) is characterized by a transient left and/or right ventricular dysfunction as a consequence of a distinctive pattern of regional wall motion abnormalities. However, a systematic evaluation of the left atrial (LA) function in patients with TTS is lacking. The ai...

  9. Deficiency of depression in adduction: clinical characteristics and surgical management of the "inverted Brown pattern".

    Science.gov (United States)

    Marsh, Justin D; Yilmaz, Pinar Topcu; Guyton, David L

    2016-02-01

    To evaluate the clinical characteristics and surgical management of patients with an "inverted Brown pattern," which is defined clinically as a hypertropia with greatest deviation in down-and-in gaze of the higher eye, having the appearance of superior oblique muscle underaction but without significant inferior oblique muscle overaction. The medical records of patients with this misalignment pattern who had cyclovertical muscle surgery at our institution from 2003 through 2015 were retrospectively reviewed; medical records were analyzed for pre- and postoperative motility patterns, fundus torsion, intraoperative findings, and type of strabismus surgery. A total of 45 patients presenting with a hyperdeviation worse in down-and-in gaze of the higher eye were included in the study. Of these, 25 (56%) had previously had inferior oblique-weakening procedures. The remainder included those with untreated superior oblique paresis (22%), previous orbital trauma (18%), or other ocular surgery (4%). The mean preoperative hyperdeviation in straight-ahead gaze was 8.7(Δ), compared with 0.9(Δ) postoperatively. Surgical success, defined as the absence of diplopia in straight-ahead gaze and not requiring further cyclovertical surgery, was achieved in 78% of patients. The motility pattern referred to as the "inverted Brown pattern" can develop in patients with orbital trauma, as previously described, or in association with superior oblique muscle paresis, most commonly after prior surgery to weaken the inferior oblique muscle. Weakening or reweakening of the inferior oblique muscle appears to correct this misalignment pattern, despite the absence of significant inferior oblique overaction preoperatively. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  10. Takotsubo (Stress Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Justin J Hourmozdi

    2017-01-01

    Full Text Available History of present illness: A 59-year-old male presented to the emergency department in shock from pneumonia. The patient was initially afebrile, pulse rate 120 beats per minute, blood pressure 117/69 mmHg, respiratory rate 42 breaths per minute, pulse oximetry 94% on a non-rebreather mask and a lactate of 14 mmol/L. He became progressively more hypotensive despite fluid resuscitation and was started on norepinephrine. Shortly after, the patient developed torsades de pointes that was terminated with intravenous push magnesium. His initial ECG had shown sinus tachycardia; however, repeat ECG showed ST-segment elevation in the inferolateral leads and the patient had troponin I elevation that peaked at 16 ng/mL. Significant findings: Bedside echocardiography showed the findings consistent with Takotsubo cardiomyopathy. Echocardiographic images are shown in subxiphoid (A and apical four chamber (B views. Note the apical ballooning appearance (asterisk of the left ventricle (LV. Discussion: Formal echocardiography confirmed features classic for Takotsubo (stress cardiomyopathy, including globally depressed left ventricle (LV ejection fraction, systolic apical ballooning appearance of the LV, mid and apical segments of LV depression, and hyper kinesis of the basal walls. Takotsubo cardiomyopathy is a syndrome known to cause ST-segment elevation on ECG, transient LV dysfunction, and dysrhythmia in the absence of acute obstructive coronary disease. There is no consensus on diagnostic criteria; however, these criteria are commonly used: 1 transient hypokinesis, akinesis, or dyskinesis in the LV mid-segments with or without apical involvement; regional wall motion abnormalities that extend beyond a single epicardial vascular distribution; and frequently, but not always, a stressful trigger 2 the absence of acute coronary disease or angiographic evidence of acute plaque rupture 3 new ECG abnormalities (ST-segment elevation and/or T-wave inversion or modest

  11. Pathogenesis of Takotsubo syndrome

    Directory of Open Access Journals (Sweden)

    Daniele Masarone

    2017-01-01

    Full Text Available Takotsubo syndrome (TTS is an enigmatic disease with a multifactorial and still unresolved pathogenesis. Postulated mechanisms include catecholamine excess, coronary artery spasm, and microvascular dysfunction, however catecholamines seem to play a central role in the pathophysiology of TTS. In facts catecholamines have relevant effects on the vasculature and myocardium. Toxic direct effects of catecholamine on myocardium are mediated by multiple pathway including functional hypoxia, metabolic changes and changes in membrane permeability leading to various electrolytic imbalances. Recently report of familial cases has suggested a genetic component. Further research is required to help clarify the proposed hypotheses and to increase our understanding of the cardiovascular responses to acute stress and the pathophysiology underpinning TTS.

  12. R2R-printed inverted OPV modules - towards arbitrary patterned designs

    Science.gov (United States)

    Välimäki, M.; Apilo, P.; Po, R.; Jansson, E.; Bernardi, A.; Ylikunnari, M.; Vilkman, M.; Corso, G.; Puustinen, J.; Tuominen, J.; Hast, J.

    2015-05-01

    We describe the fabrication of roll-to-roll (R2R) printed organic photovoltaic (OPV) modules using gravure printing and rotary screen-printing processes. These two-dimensional printing techniques are differentiating factors from coated OPVs enabling the direct patterning of arbitrarily shaped and sized features into visual shapes and, increasing the freedom to connect the cells in modules. The inverted OPV structures comprise five layers that are either printed or patterned in an R2R printing process. We examined the rheological properties of the inks used and their relationship with the printability, the compatibility between the processed inks, and the morphology of the R2R-printed layers. We also evaluate the dimensional accuracy of the printed pattern, which is an important consideration in designing arbitrarily-shaped OPV structures. The photoactive layer and top electrode exhibited excellent cross-dimensional accuracy corresponding to the designed width. The transparent electron transport layer extended 300 µm beyond the designed values, whereas the hole transport layer shrank 100 µm. We also examined the repeatability of the R2R fabrication process when the active area of the module varied from 32.2 cm2 to 96.5 cm2. A thorough layer-by-layer optimization of the R2R printing processes resulted in realization of R2R-printed 96.5 cm2 sized modules with a maximum power conversion efficiency of 2.1% (mean 1.8%) processed with high functionality.

  13. Degradation patterns in water and oxygen of an inverted polymer solar cell.

    Science.gov (United States)

    Norrman, Kion; Madsen, Morten V; Gevorgyan, Suren A; Krebs, Frederik C

    2010-12-01

    The spatial distribution of reaction products in multilayer polymer solar cells induced by water and oxygen atmospheres was mapped and used to elucidate the degradation patterns and failure mechanisms in an inverted polymer solar cell. The active material comprised a bulk heterojunction formed by poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl-C61-butyric acid methyl ester (PCBM) sandwiched between a layer of zinc oxide and a layer of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) that acted as, respectively, electron and hole transporting layers between the active material and the two electrodes indium-tin-oxide (ITO) and printed silver. X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) in conjunction with isotopic labeling using H(2)(18)O and (18)O(2) enabled detailed information on where and to what extent uptake took place. A comparison was made between the use of a humid (oxygen-free) atmosphere and a dry oxygen atmosphere during testing of devices that were kept in the dark and devices that were subjected to illumination under simulated sunlight. It was found that the reactions taking place at the interface between the active layer and the PEDOT:PSS were the major cause of device failure in the case of these inverted devices, which are compatible with full roll-to-roll (R2R) coating and industrial manufacture. The PEDOT:PSS was found to phase separate, with the PEDOT-rich phase being responsible for most of the interface degradation in oxygen atmospheres. In water atmospheres, little chemically induced degradation was observed, whereas a large partially reversible dependence of the open circuit voltage on the relative humidity was observed. In addition, temporal aspects are discussed in regard to degradation mechanisms. Finally, analytical aspects in regard to storing devices are discussed.

  14. The Inverted Discoid Meniscus Segment: Clinical, Radiographic, and Arthroscopic Description of a Hidden Tear Pattern.

    Science.gov (United States)

    LaMont, Lauren; Ellis, Henry; Wise, Kelsey; Wilson, Philip

    2016-06-01

    A flipped, or inverted, meniscus segment is easily visualized in the normal meniscus. However, an inverted discoid meniscus segment may be difficult to appreciate because the tear occurs more centrally and leaves more meniscal rim; thus, it may be undertreated if not addressed during arthroscopy. To describe findings on clinical history, radiographs, MRI, and arthroscopy of a lateral discoid meniscus with an inverted segment and compare them with characteristics of a lateral discoid meniscus without an inverted segment. Case-control study; Level of evidence, 3. Between 2009 and 2012, a retrospective series of 121 consecutive knee arthroscopies for symptomatic lateral discoid meniscus were reviewed for the presence of an inverted fragment. Chart review of clinical presentation, operative reports, radiographic images, and arthroscopic images was performed. Comparative analysis of the clinical presentation between lateral discoid menisci with an inverted segment and noninverted lateral discoid menisci was performed by use of Fisher exact test and Mann-Whitney test. Nineteen patients with an inverted discoid meniscus segment (14 males, 5 females; average age, 15.0 years; range, 9.5-17.0 years) were compared with 102 patients with a noninverted discoid meniscus (53 males, 49 females; average age, 12.3 years; range, 5-17.0 years) (P = .011 for sex and P meniscus patients with an inverted segment had activity-related knee pain. Only 4 patients (21.0%) reported mechanical symptoms. Patients with an inverted discoid segment, compared with patients with discoid menisci without inverted segments, were more likely to have instability and effusion (P = .012 and P meniscus patients with an inverted segment (94.7%) had an injury, while only 41.2% of patients with noninverted symptomatic discoid menisci had an injury (P meniscus. During arthroscopy, the inverted discoid segment appeared normal, without a tear; upon probing, however, the inverted segment could be exposed. An

  15. Fully patterned and low temperature transparent ZnO-based inverters

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Heredia, G. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Department of Materials Science and Engineering, University of Texas at Dallas (United States); Mejia, I.; Rivas-Aguilar, M.E.; Hernandez-Como, N. [Department of Materials Science and Engineering, University of Texas at Dallas (United States); Martinez-Landeros, V.H. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Department of Materials Science and Engineering, University of Texas at Dallas (United States); Aguirre-Tostado, F.S. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Quevedo-Lopez, M.A., E-mail: mquevedo@utdallas.edu [Department of Materials Science and Engineering, University of Texas at Dallas (United States)

    2013-10-31

    The fabrication and characterization of transparent logic inverters based on zinc oxide (ZnO) thin film transistors (TFTs) is reported. The inverters are fabricated using standard photolithographic techniques on glass substrates, and the entire fabrication process temperature is maintained < 100 °C, which render the devices suitable for flexible and transparent electronics applications. Pulsed laser deposition is used to deposit aluminum-doped zinc oxide and ZnO as electrode and active semiconductor materials, respectively. Electrical characterization for individual TFTs demonstrate mobilities of ∼ 10 cm{sup 2}/V-s, threshold voltages of 6 V, sub-threshold slopes of 630 mV/decade and I{sub ON}/I{sub OFF} ratios of 5 × 10{sup 6}. Films characterized by UV-Vis showed optical transmission > 80% in the visible spectrum. The inverters are analyzed with AC input signals at frequencies of 100 and 500 Hz. The AC response shows an average rise and fall time transitions of 0.65 and 0.44 ms, respectively. Measured inverters delay is in the order of 0.21 ms. - Highlights: • Logic inverters based on zinc oxide thin film transistors. • Inverters fabricated using temperatures below 100 °C and standard photolithography. • Transparent aluminum-doped zinc oxide as gate, drain and source electrodes. • Devices with total transmittance in the visible range above 80%. • AC inverter response up to 500 Hz.

  16. Tako-tsubo cardiomyopathy after a quarrel.

    African Journals Online (AJOL)

    Conclusion: We report a case of Tako-tsubo cardiomyopathy after a quarrel, implicating that severe emotional or physical stress could trigger myocardial stunning. Keywords: Tako-tsubo cardiomyopathy, ocular trauma, blindness, postmenopause. DOI: http://dx.doi.org/10.4314/ahs.v15i4.39. Cite as: Jiang D-M, Sun Z-W, Han ...

  17. Biomechanics of gecko locomotion: the patterns of reaction forces on inverted, vertical and horizontal substrates

    International Nuclear Information System (INIS)

    Wang, Zhouyi; Dai, Zhendong; Ji, Aihong; Xing, Qiang; Ren, Lei; Dai, Liming

    2015-01-01

    The excellent locomotion ability of geckos on various rough and/or inclined substrates has attracted scientists’ attention for centuries. However, the moving ability of gecko-mimicking robots on various inclined surfaces still lags far behind that of geckos, mainly because our understanding of how geckos govern their locomotion is still very poor. To reveal the fundamental mechanism of gecko locomotion and also to facilitate the design of gecko-mimicking robots, we have measured the reaction forces (RFs) acting on each individual foot of moving geckos on inverted, vertical and horizontal substrates (i.e. ceiling, wall and floor), have associated the RFs with locomotion behaviors by using high-speed camera, and have presented the relationships of the force components with patterns of reaction forces (PRFs). Geckos generate different PRF on ceiling, wall and floor, that is, the PRF is determined by the angles between the direction of gravity and the substrate on which geckos move. On the ceiling, geckos produce reversed shear forces acting on the front and hind feet, which pull away from the body in both lateral and fore-aft directions. They use a very large supporting angle from 21° to 24° to reduce the forces acting on their legs and feet. On the floor, geckos lift their bodies using a supporting angle from 76° to 78°, which not only decreases the RFs but also improves their locomotion ability. On the wall, geckos generate a reliable self-locking attachment by using a supporting angle of 14.8°, which is only about half of the critical angle of detachment. (paper)

  18. Biomechanics of gecko locomotion: the patterns of reaction forces on inverted, vertical and horizontal substrates.

    Science.gov (United States)

    Wang, Zhouyi; Dai, Zhendong; Ji, Aihong; Ren, Lei; Xing, Qiang; Dai, Liming

    2015-02-04

    The excellent locomotion ability of geckos on various rough and/or inclined substrates has attracted scientists' attention for centuries. However, the moving ability of gecko-mimicking robots on various inclined surfaces still lags far behind that of geckos, mainly because our understanding of how geckos govern their locomotion is still very poor. To reveal the fundamental mechanism of gecko locomotion and also to facilitate the design of gecko-mimicking robots, we have measured the reaction forces (RFs) acting on each individual foot of moving geckos on inverted, vertical and horizontal substrates (i.e. ceiling, wall and floor), have associated the RFs with locomotion behaviors by using high-speed camera, and have presented the relationships of the force components with patterns of reaction forces (PRFs). Geckos generate different PRF on ceiling, wall and floor, that is, the PRF is determined by the angles between the direction of gravity and the substrate on which geckos move. On the ceiling, geckos produce reversed shear forces acting on the front and hind feet, which pull away from the body in both lateral and fore-aft directions. They use a very large supporting angle from 21° to 24° to reduce the forces acting on their legs and feet. On the floor, geckos lift their bodies using a supporting angle from 76° to 78°, which not only decreases the RFs but also improves their locomotion ability. On the wall, geckos generate a reliable self-locking attachment by using a supporting angle of 14.8°, which is only about half of the critical angle of detachment.

  19. Takotsubo cardiomyopathy: a case report.

    Science.gov (United States)

    Johar, Sandeep; Prasad, Heramba; Kozman, Hani

    2007-01-01

    A 57-year-old Caucasian woman presented to the emergency department with chest discomfort after testifying in a child custody battle in court. Electrocardiography (ECG) revealed ST-segment elevation in the lateral leads, and T-wave inversions in the inferior and lateral leads. The creatine kinase, creatine kinase-MB, and troponin I concentrations were elevated on presentation. Despite the ECG changes and elevated cardiac markers, coronary angiography demonstrated normal arteries. Left ventricular angiogram revealed an aneurysm at the apex. Takotsubo cardiomyopathy was diagnosed on the basis of these characteristic findings. The patient was discharged on her third hospital day without any complications from the coronary angiography.

  20. Tako-tsubo cardiomyopathy after a quarrel.

    African Journals Online (AJOL)

    com. Tel: +86571 85519933;. Fax:+8657187236569. It was first recognized in Japan ... coronary artery disease on cardiac catheterization8. The pathophysiological mechanism associated with. Tako-tsubo cardiomyopathy is higher prevalence in.

  1. RATIONAL PHARMACOTHERAPY IN TAKOTSUBO CARDIOMYOPATHY

    Directory of Open Access Journals (Sweden)

    S. Marchev

    2012-01-01

    Full Text Available Rational pharmacotherapy in Takotsubo cardiomyopathy is based on clinical picture and data of functional and laboratory investigations of concrete patient. In patients with hypotension and moderate-to-severe left ventricle outflow tract obstruction inotropic agents must not to be used because they can worsen the degree of obstruction. In these patients beta blockers can improve hemodynamics by causing resolution of the obstruction. If intraventricular thrombus is detected, anticoagulation for at least 3 months is recommended. The duration of anticoagulant therapy may be modified depending on the extent of cardiac function recovery and thrombus resolution. For patients without thrombus but with severe left ventricular dysfunction, anticoagulation is recommended until the akinesis or dyskinesis has resolved but not more than 3 months.

  2. Stimulant-related Takotsubo cardiomyopathy.

    Science.gov (United States)

    Butterfield, Mike; Riguzzi, Christine; Frenkel, Oron; Nagdev, Arun

    2015-03-01

    Takotsubo cardiomyopathy (TC) is a rare but increasingly recognized mimic of acute coronary syndrome. Patients present with angina,ST-segment changes on electrocardiogram (both elevations and depressions),and rapid rises in cardiac biomarkers. Many kinds of stressful events have been associated with TC, but only a handful of drug-related cases have previously been reported. We describe the case of a 58-year-old woman who developed TC 2 days after crack cocaine use, a diagnosis first suggested as bedside echocardiography in the emergency department.Recognition of the classic echocardiographic appearance of TC—apical hypokinesis causing “ballooning” of the left ventricle during systole—may greatly assist providers in the early identification of this condition.

  3. Degradation Patterns in Water and Oxygen of an Inverted Polymer Solar Cell

    DEFF Research Database (Denmark)

    Norrman, Kion; Vesterager Madsen, Morten; Gevorgyan, Suren

    2010-01-01

    and the two electrodes indium−tin−oxide (ITO) and printed silver. X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) in conjunction with isotopic labeling using H218O and 18O2 enabled detailed information on where and to what extent uptake took place...... by poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl-C61-butyric acid methyl ester (PCBM) sandwiched between a layer of zinc oxide and a layer of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) that acted as, respectively, electron and hole transporting layers between the active material...... layer and the PEDOT:PSS were the major cause of device failure in the case of these inverted devices, which are compatible with full roll-to-roll (R2R) coating and industrial manufacture. The PEDOT:PSS was found to phase separate, with the PEDOT-rich phase being responsible for most of the interface...

  4. Stress-induced cardiomyopathy (Takotsubo – broken heart and mind?

    Directory of Open Access Journals (Sweden)

    Redfors B

    2013-04-01

    Full Text Available Björn Redfors, Yangzhen Shao, Elmir Omerovic Department of Molecular and Clinical Medicine, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden Abstract: Stress-induced cardiomyopathy (SIC, also known as Takotsubo cardiomyopathy, is characterized by severe but potentially reversible regional left ventricular wall motion abnormalities, ie, akinesia, in the absence of explanatory angiographic evidence of a coronary occlusion. The typical pattern is that of an akinetic apex with preserved contractions in the base, but other variants are also common, including basal or midmyocardial akinesia with preserved apical function. The pathophysiology of SIC remains largely unknown but catecholamines are believed to play a pivotal role. The diverse array of triggering events that have been linked to SIC are arbitrarily categorized as either emotional or somatic stressors. These categories can be considered as different elements of a continuous spectrum, linked through the interface of neurology and psychiatry. This paper reviews our current knowledge of SIC, with focus on the intimate relationship between the brain and the heart. Keywords: stress-induced cardiomyopathy, takotsubo cardiomyopathy, catecholamine, cerebral injury, emotional stress, somatic stress

  5. Takotsubo cardiomyopathy in a snake bite victim: a case report ...

    African Journals Online (AJOL)

    Takotsubo cardiomyopathy occurs in patients with severe emotional or physiologic stress. The prognosis is usually favorable, and the left ventricular wall motion dyskinesis normalizes within days to weeks. In this paper we report a case of snake bite complicated by takotsubo cardiomyopathy. We advise physicians to ...

  6. Electrolyte Disorders as Triggers for Takotsubo Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Fabio Andreozzi

    2018-02-01

    Full Text Available A 56-year-old woman presented with cognitive impairment, confusion and slowed speech, muscle cramps and peripheral paraesthesia preceded by vomiting. Blood tests revealed severe hypokalaemia, hyponatremia, hypomagnesemia and hypocalcaemia. Following a diagnosis of Takotsubo cardiomyopathy based on ultrasonography, the patient was treated with electrolyte supplementation and recovered within 48h. When heart failure is suspected, electrolyte abnormalities should be carefully ruled out as they can affect cardiac function.

  7. Takotsubo cardiomyopathy in amiodarone-induced hyperthyroidism

    OpenAIRE

    Ismael Capel; Elisabet Tasa-Vinyals; Albert Cano-Palomares; Irene Bergés-Raso; Lara Albert; Mercedes Rigla; Assumpta Caixàs

    2017-01-01

    Summary Takotsubo cardiomyopathy (TC) is an atypical, severe but reversible form of acute heart insufficiency. It typically presents with left ventricular failure, transient apical and mid-segments hypokinesis, absence of significant coronary stenosis and new electrographic abnormalities and/or elevation in serum cardiac enzymes. Although TC (?broken heart syndrome?) has classically been associated with emotional trauma, evidence suggests that other precipitants might exist, including iatroge...

  8. Takotsubo Cardiomyopathy in Intensive Care Unit: Prevention, Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Hannah Masoud

    2016-01-01

    Full Text Available Accurate diagnosis of Takotsubo Cardiomyopathy has substantial prognostic implications in an intensive care unit, given its increased mortality risk and association with life-threatening complications. This report seeks to discuss diagnostic modalities that can be useful in accurately differentiating Takotsubo Cardiomyopathy from Acute Coronary Syndrome, and also briefly discuss prevention and management of this cardiomyopathy in an intensive care unit. For critically ill Takotsubo patients, intensive clinicians can consider establishment of diagnosis by specific electrocardiograph changes, distinctive marked release of cardiac enzymes, characteristic echocardiograph findings, as well as invasive coronary angiography or noninvasive cardiac magnetic imaging.

  9. An inverted AlGaAs/GaAs patterned-Ge tunnel junction cascade concentrator solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Venkatasubramanian, R. (Research Triangle Inst., Research Triangle Park, NC (United States))

    1993-01-01

    This report describes work to develop inverted-grown Al[sub 0.34]Ga[sub 0.66]As/GaAs cascades. Several significant developments are reported on as follows: (1) The AM1.5 1-sun total-area efficiency of the top Al[sub 0.34]Ga[sub 0.66]As cell for the cascade was improved from 11.3% to 13.2% (NREL measurement [total-area]). (2) The cycled'' organometallic vapor phase epitaxy growth (OMVPE) was studied in detail utilizing a combination of characterization techniques including Hall-data, photoluminescence, and secondary ion mass spectroscopy. (3) A technique called eutectic-metal-bonding (EMB) was developed by strain-free mounting of thin GaAs-AlGaAs films (based on lattice-matched growth on Ge substrates and selective plasma etching of Ge substrates) onto Si carrier substrates. Minority-carrier lifetime in an EMB GaAs double-heterostructure was measured as high as 103 nsec, the highest lifetime report for a freestanding GaAs thin film. (4) A thin-film, inverted-grown GaAs cell with a 1-sun AM1.5 active-area efficiency of 20.3% was obtained. This cell was eutectic-metal-bonded onto Si. (5) A thin-film inverted-grown, Al[sub 0.34]Ga[sub 0.66]As/GaAs cascade with AM1.5 efficiency of 19.9% and 21% at 1-sun and 7-suns, respectively, was obtained. This represents an important milestone in the development of an AlGaAs/GaAs cascade by OMVPE utilizing a tunnel interconnect and demonstrates a proof-of-concept for the inverted-growth approach.

  10. Neuroticism, depression and anxiety in takotsubo cardiomyopathy

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Bang, Lia E; Holmvang, Lene

    2016-01-01

    BACKGROUND: Takotsubo cardiomypathy (TTC) causes acute reversible heart failure. Prior studies have indicated that the syndrome is associated with traits such as social inhibition, chronic psychological stress, and anxio-depressive disorders. The objective of this study was to further characterize...... key psychological/psychopathological traits of patients with TTC. METHODS: A survey of three groups was conducted: I) Female post-recovery TTC patients admitted between October 1(st) 2009 and December 10(th) 2014, II) Age, gender and geographically matched ST-elevation myocardial infarction (STEMI...

  11. Psychological distress and personality factors in takotsubo cardiomyopathy

    NARCIS (Netherlands)

    Smeijers, L; Szabó, B M; Kop, W J

    2016-01-01

    Background Takotsubo cardiomyopathy (TCC) is a transient condition characterised by severe left ventricular dysfunction combined with symptoms and signs mimicking myocardial infarction. Emotional triggers are common, but little is known about the psychological background characteristics of TCC. This

  12. [Inverted nipples].

    Science.gov (United States)

    Saltvig, Iselin; Sjøstrand, Helle; Oldenburg, Mette Holmqvist; Matzen, Steen Henrik

    2016-10-17

    Inverted nipples is an anatomical variation which can be uni- or bilateral, congenital or acquired. The degree of inversion can vary from slight to severe. Treatment can be surgical or non-surgical and should depend on the degree of functional problems. Non-surgical treatment can be beneficial, does not risk affecting sensibility, spares the lactiferous ducts, and therefore does not risk any interference with breast-feeding. Surgical options should only be considered when non-surgical treatment is insufficient.

  13. [Perioperative approach of patient with takotsubo syndrome].

    Science.gov (United States)

    Barros, Joana; Gomes, Diana; Caramelo, Susana; Pereira, Marta

    Takotsubo cardiomyopathy (TCM) is a stress-induced cardiomyopathy. It is characterized by an acute onset of symptoms and electrocardiographic abnormalities mimicking an acute coronary syndrome in the absence of obstructive coronary artery disease. Any anesthetic-surgical event corresponds to a stressful situation, so the anesthetic management of patients with TCM requires special care throughout the perioperative period. We describe the anesthetic management of a patient with a confirmed diagnosis of TCM undergoing segmental colectomy. Female patient, 55 years old, ASA III, with history of takotsubo syndrome diagnosed 2 years ago, scheduled for segmental colectomy. The patient, without other changes in preoperative evaluation, underwent general anesthesia associated with lumbar epidural and remained hemodynamically stable during the 2hours of surgery. After a brief stay in the Post-Anesthesia Care Unit, she was transferred to the Intermediate Care Unit (IMCU), with epidural analgesia for postoperative period. TCM is a rare disease which true pathophysiology remains unclear, as well as the most appropriate anesthetic-surgical strategy. In this case, through a preventive approach, with close monitoring and the lowest possible stimulus, all the perioperative period was uneventful. Because it is a rare disease, this report could help to raise awareness about TCM. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  14. Spontaneous coronary artery dissection and takotsubo syndrome: The chicken or the egg causality dilemma.

    Science.gov (United States)

    Y-Hassan, Shams; Themudo, Raquel; Maret, Eva

    2017-06-01

    Acute coronary syndrome (ACS) including spontaneous coronary artery dissection (SCAD) has been reported to trigger its own clinical twin takotsubo syndrome (TS). The pathogenetic association between SCAD and TS remains to be elucidated. The two diseases afflict predominantly women and both conditions may be triggered by an emotional stress factor and an unusual extreme physical exercise. Herein, we describe a case of 54-year-old woman presenting with ACS caused by an obtuso-marginal SCAD. Concurrently, the patient had typical clinical features and course of mid-apical pattern of TS. The causal link between the two conditions is discussed. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Takotsubo cardiomyopathy in amiodarone-induced hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Ismael Capel

    2017-02-01

    Full Text Available Takotsubo cardiomyopathy (TC is an atypical, severe but reversible form of acute heart insufficiency. It typically presents with left ventricular failure, transient apical and mid-segments hypokinesis, absence of significant coronary stenosis and new electrographic abnormalities and/or elevation in serum cardiac enzymes. Although TC (‘broken heart syndrome’ has classically been associated with emotional trauma, evidence suggests that other precipitants might exist, including iatrogenic and thyroid-mediated forms. Thyroid disease is a relatively common comorbidity in TC patients. We report a case of TC in a postmenopausal female with no history of emotional trauma or other potential precipitant factors who was diagnosed with amiodarone-induced hyperthyroidism during her hospital stay. Though some case reports of thyroidrelated TC exist, we are not aware of any other reported case of TC precipitated by amiodarone-induced hyperthyroidism.

  16. [Intermediate term outcome in 70 patients with Tako-Tsubo syndromes].

    Science.gov (United States)

    Réglat, C; Chevalier, J-M; Coste, P; Godon, P; Renault, L; Roudaut, R; Seguy, B; Gerbaud, E

    2014-04-01

    Tako-Tsubo syndrome is a reversible left ventricular myocardial dysfunction. There are few publications on its evolution and the purpose of this study is to describe the medium-term outcome of patients who presented this pathology. This retrospective study included 70 patients presenting with Tako-Tsubo syndrome who were referred to Haut-Lévèque hospital between November 2003 and January 2012. The parameters included in follow-up were: number of cardiovascular events, recurrence, electrocardiographic and echocardiographic evolution. Sixty-eight patients had a mean follow-up of 4.8±2.4 years. The survival rate was 92%, 39 patients (57%) showed no cardiovascular symptoms, 12 (18%) had one or more new episodes of chest pain and 4 (6%) had stage II dyspnoea on the NYHA classification scale. One patient had a recurrence 6.5 years later, triggered by the same stress as the first instance. Forty-five patients (64%) had ECGs which evolved in the early days to diffuse T-wave inversion. In the medium term, 32 (54%) patients had a normal ECG, 19 (32%) had inverted T-waves in precordial leads and 2 (3%) had Q-waves. In terms of echocardiography, left ventricular ejection fraction was normal in all with variable delays. Four patients continued to have apical hypokinesia. This study shows that the medium-term outlook is favourable in terms of cardiovascular mortality and that recurrence is rare. It highlights, however, the persistence of electrocardiographic and echocardiographic abnormalities. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Takotsubo Cardiomyopathy and Catatonia in the Setting of Benzodiazepine Withdrawal

    Directory of Open Access Journals (Sweden)

    Teng J. Peng

    2016-01-01

    Full Text Available We report two serious and unusual complications of benzodiazepine withdrawal in a single patient: takotsubo cardiomyopathy and catatonia. This 61-year-old female patient was brought to the emergency department with lethargy and within hours had declined into a state of catatonia. Although there was never a complaint of chest pain, ECG showed deep anterior T-wave inversions and cardiac enzymes were elevated. An echocardiogram was consistent with takotsubo cardiomyopathy. She later received 1 mg of midazolam and within minutes had resolution of catatonic symptoms. Careful history revealed that she had omitted her daily dose of lorazepam for 3 days prior to admission. To our knowledge, the case presented herein is the first report of simultaneous catatonia and takotsubo cardiomyopathy in the setting of benzodiazepine withdrawal. The pathogenesis of both conditions is poorly understood but may be indirectly related to the sudden decrease in γ-aminobutyric acid (GABA signaling during benzodiazepine withdrawal.

  18. Takotsubo cardiomyopathy in myasthaenia gravis crisis confirmed by cardiac MRI.

    Science.gov (United States)

    Harries, I B; Levoir, H; Bucciarelli-Ducci, C; Ramcharitar, S

    2015-09-28

    Myasthaenia gravis crisis and Takotsubo cardiomyopathy are rare conditions that can be precipitated by emotional or physical stress. Myasthaenia gravis has a variety of cardiac manifestations but Takotsubo cardiomyopathy, particularly in male patients, has rarely been reported. We describe a unique case of a 70-year-old man who developed Takotsubo cardiomyopathy during his first presentation with a myasthaenia gravis crisis. He had not received plasmapharesis or immunoglobulin therapy. Striking ECG traces and cardiac MRI helped to confirm the diagnosis. Cardiac manifestations of myasthaenia gravis and myasthaenia gravis itself have overlapping symptoms; the importance of cardiac monitoring and clinical vigilance in such cases is discussed. The utility of cardiac MRI in assessing cardiac manifestations of myasthaenia gravis is also highlighted. 2015 BMJ Publishing Group Ltd.

  19. Psychological disorders in adults with inherited cardiomyopathies and Takotsubo syndrome

    OpenAIRE

    Mariana Suárez Bagnasco; Iván J. Núñez-Gil

    2016-01-01

    Realizamos una revisión narrativa sobre trastornos psicológicos en adultos con diagnóstico de síndrome de Takotsubo y miocardiopatías hereditarias. Utilizando las bases de datos PubMed y PsycINFO buscamos los trabajos relevantes publicados entre 2000 y 2015. Encontramos doce estudios que exploran alteraciones psicológicas en síndrome de Takotsubo y ocho estudios sobre miocardiopatías hereditarias: cinco enrolaron pacientes con miocardiopatía hipertrófica, dos miocardiopatía dilatada, uno mioc...

  20. Strain bidimensional na cardiopatia de Takotsubo Two-dimensional strain in Takotsubo cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Carlos Bellini G. Gomes

    2010-08-01

    Full Text Available Este relato apresenta o seguimento tardio de um caso de cardiomiopatia de Takotsubo com boa evolução clínica e melhora da função sistólica global ventricular esquerda. Contudo, observou-se persistência de significativa disfunção sistólica regional longitudinal que foi avaliada por meio de nova técnica ecocardiográfica (speckle tracking, com as medidas do strain (S e strain rate (SR correspondentes. Ressaltamos a importância desse novo método para o acompanhamento dessa cardiopatia, pois permite identificar os pacientes que persistem com disfunção sistólica e que possivelmente serão beneficiados com a manutenção da terapêutica clínica.This report presents the late follow-up of a case of Takotsubo cardiomyopathy with good clinical outcome and improved left ventricular global systolic function. However, there was persistence of significant regional longitudinal systolic dysfunction evaluated using a new echocardiographic technique (speckle tracking, with corresponding measures of strain (S and strain rate (SR. We emphasize the importance of this new method to monitoring this cardiomyopathy, since it identifies patients with persistent systolic dysfunction who will possibly benefit from maintenance of clinical therapy

  1. Cascaded Multicell Trans-Z-Source Inverters

    DEFF Research Database (Denmark)

    Li, Ding; Chiang Loh, Poh; Zhu, Miao

    2013-01-01

    Inverters with high-output voltage gain usually face the problem of high-input current flowing through their components. The problem might further be exaggerated if the inverters use high-frequency magnetic devices like transformers or coupled inductors. Leakage inductances of these devices must...... strictly be small to prevent overvoltages caused by switching of their winding currents. To avoid these related problems, cascaded trans-Z-source inverters are proposed. They use multiple magnetic cells in an alternately cascading pattern rather than a single magnetic cell with large turns ratio....... Simulation and experimental results have shown that the multicell inverters can produce the same high-voltage gain, while keeping currents and voltages of the components low. The inverters can also step down their output voltages like a traditional voltage-source inverter without compromising waveform...

  2. In situ patterning of organic molecules in aqueous solutions using an inverted electron-beam lithography system

    Science.gov (United States)

    Miyazako, Hiroki; Ishihara, Kazuhiko; Mabuchi, Kunihiko; Hoshino, Takayuki

    2016-06-01

    A method for in situ controlling the detachment and deposition of organic molecules such as sugars and biocompatible polymers in aqueous solutions by electron-beam (EB) scan is proposed and evaluated. It was demonstrated that EB irradiation could detach 2-methacryloyloxyethyl phosphorylcholine (MPC) polymers from a silicon nitride membrane. Moreover, organic molecules such as cationic polymers and sugars could be deposited on the membrane by EB irradiation. Spatial distributions of scattered electrons were numerically simulated, and acceleration voltage dependences of the detachment and deposition phenomena were experimentally measured. The simulations and experimental results suggest that the detachment of MPC polymers is mainly due to electrical effects of primary electrons, and that the deposition of organic molecules is mainly due to chemical reactions induced by primary electrons. In view of these findings, the proposed method can be applied to in situ and nanoscale patterning such as the fabrication of cell scaffolds.

  3. Daytime increase in caloric intake without change in total 24-h caloric intake can increase adiposity but not total bodyweight in rats with inverted feeding pattern.

    Science.gov (United States)

    Rocha, Lanni Sarmento da; de Matos, Rhowena Jane Barbosa; de Souza, Julliet Araújo; Costa, Ana Carolina Oliveira; Lopes de Souza, Sandra; Muniz, Gisélia de Santana; Nascimento, Elizabeth do

    2017-09-01

    The goal of this study was to evaluate the effect of the food availability period on body weight, self-selection of macronutrients, adiposity, lipoprotein, and serum glucose profiles without changing energy intake. Young male rats were divided into 2 groups according to the availability of food during the light and dark phases of the cycle, forming 2 groups: control group (CG) and group with inverted feeding pattern (IFPG). Before inversion of food availability on the 80th day, circadian food intake was measured every 4 h over 24 h during 3 days. The glycemic curve, an oral test for glucose tolerance, and self-selection of macronutrients were evaluated. Blood samples were collected for analysis of fasting glucose, triglycerides, and total cholesterol fractions. The IFPG showed an increase in fasting glucose in the dark phase of the cycle, changes in the glycemic curve, and oral glucose tolerance test. It also showed increased abdominal and liver fat and distinct choice of macronutrients compared with the CG. A change in the availability of food according to the phase of the circadian cycle produces changes in glucose and feeding circadian rhythm culminating in increased abdominal and hepatic fat. These effects can increase the risk of metabolic disorders and installation of chronic diseases.

  4. Cardiogenic shock in Takotsubo cardiomyopathy: a focus on management.

    Science.gov (United States)

    Doucet, Katie M; Labinaz, Marino X; Beauchesne, Luc M; Burwash, Ian G

    2015-01-01

    Takotsubo cardiomyopathy has become a well recognized mimicker of acute coronary syndrome. Patients generally do well, although a minority can develop life-threatening complications. We present a case of 1 such patient in a branched self-assessment format designed to challenge the reader's clinical management skills. Copyright © 2015 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. Takotsubo cardiomyopathy after a dancing session: a case report.

    Science.gov (United States)

    Kaballo, Mohammed A; Yousif, Abdelazim; Abdelrazig, Awadalla M; Ibrahim, Ammar A; Hennessy, Terence G

    2011-10-31

    Stress-induced (Takotsubo) cardiomyopathy is a rare form of cardiomyopathy which presents in a manner similar to that of acute coronary syndrome. This sometimes leads to unnecessary thrombolysis therapy. The pathogenesis of this disease is still poorly understood. We believe that reporting all cases of Takotsubo cardiomyopathy will contribute to a better understanding of this disease. Here, we report a patient who, in the absence of any recent stressful events in her life, developed the disease after a session of dancing. A 69-year-old Caucasian woman presented with features suggestive of acute coronary syndrome shortly after a session of dancing. Echocardiography and a coronary angiogram showed typical features of Takotsubo cardiomyopathy and our patient was treated accordingly. Eight weeks later, her condition resolved completely and the results of echocardiography were totally normal. Takotsubo cardiomyopathy, though transient, is a rare and serious condition. Although it is commonly precipitated by stressful life events, these are not necessarily present. Our patient was enjoying one of her hobbies (that is, dancing) when she developed the disease. This case has particular interest in medicine, especially for the specialties of cardiology and emergency medicine. We hope that it will add more information to the literature about this rare condition.

  6. Takotsubo-kardiomyopati er akut hjertesvigt induceret af stress

    DEFF Research Database (Denmark)

    Fuchs, Annette Maria; Bang, Lia Evi; Holmvang, Lene

    2016-01-01

    Takotsubo cardiomyopathy (TTC) is an acute cardiac syndrome, characterized by transient left ventricular dysfunction often following a stressful event in post-menopausal women. Symptoms are indistinguishable from myocardial infarction. However, TTC patients do not have a culprit lesion on acute...

  7. Pheochromocytoma presenting as takotsubo-like cardiomyopathy following delivery.

    Science.gov (United States)

    Jóźwik-Plebanek, Katarzyna; Pęczkowska, Mariola; Klisiewicz, Anna; Wrzesiński, Kazimierz; Prejbisz, Aleksander; Niewada, Maciej; Kabat, Marek; Szperl, Małgorzata; Eisenhofer, Graeme; Lenders, Jacques W; Januszewicz, Andrzej

    2014-12-01

    Diagnosis of pheochromocytoma during pregnancy can be difficult, and the tumor carries an unfavorable prognosis if not diagnosed and treated in a timely manner. To present a case of Takotsubo-like cardiomyopathy characterized by transient left ventricular apical ballooning due to pheochromocytoma following delivery. A few hours after Caesarean section, a 32-year-old Caucasian female presented with pulmonary edema followed by cardiac arrest with echocardiographic and ventriculographic evidence of reversible acute myocardial failure characteristic of Takotsubo-like cardiomyopathy. A previously unrecognized adrenal pheochromocytoma was found during her clinical work-up. Left ventricle (LV) function normalized after surgical removal of the tumor, which was carried out after implementing an alpha-adrenoreceptor blockade. Hemorrhagic necrosis of the pheochromocytoma was seen on histopathologic analysis; this may have triggered the sequence of events leading to the development of Takotsubo-like cardiomyopathy and hemodynamic collapse. To the best of our knowledge, this is the first reported case of Takotsubo-like cardiomyopathy related to pheochromocytoma following delivery. This emphasizes the increased cardiovascular risk if pheochromocytoma is not diagnosed and treated in a timely manner, especially during pregnancy.

  8. Three-dimensional entertainment as a novel cause of takotsubo cardiomyopathy.

    Science.gov (United States)

    Taylor, Montoya; Amin, Anish; Bush, Charles

    2011-11-01

    Takotsubo cardiomyopathy (TC) is an uncommon entity. It is known to occur in the setting of extreme catecholamine release and results in left ventricular dysfunction without evidence of angiographically definable coronary artery disease. There have been no published reports of TC occurring with visual stimuli, specifically 3-dimensional (3D) entertainment. We present a 55-year-old woman who presented to her primary care physician's office with extreme palpitations, nausea, vomiting, and malaise movie at her local theater. Her electrocardiogram demonstrated ST elevations in aVL and V1, prolonged QTc interval, and T-wave inversions in leads I, II, aVL, and V2-V6. Coronary angiography revealed angiographically normal vessels, elevated left ventricular filling pressures, and decreased ejection fraction with a pattern of apical ballooning. The presumed final diagnosis was TC, likely due to visual-auditory-triggered catecholamine release causing impaired coronary microcirculation. © 2011 Wiley Periodicals, Inc.

  9. Takotsubo cardiomyopathy in amiodarone-induced hyperthyroidism.

    Science.gov (United States)

    Capel, Ismael; Tasa-Vinyals, Elisabet; Cano-Palomares, Albert; Bergés-Raso, Irene; Albert, Lara; Rigla, Mercedes; Caixàs, Assumpta

    2017-01-01

    Takotsubo cardiomyopathy (TC) is an atypical, severe but reversible form of acute heart insufficiency. It typically presents with left ventricular failure, transient apical and mid-segments hypokinesis, absence of significant coronary stenosis and new electrographic abnormalities and/or elevation in serum cardiac enzymes. Although TC ('broken heart syndrome') has classically been associated with emotional trauma, evidence suggests that other precipitants might exist, including iatrogenic and thyroid-mediated forms. Thyroid disease is a relatively common comorbidity in TC patients. We report a case of TC in a postmenopausal female with no history of emotional trauma or other potential precipitant factors who was diagnosed with amiodarone-induced hyperthyroidism during her hospital stay. Though some case reports of thyroid-related TC exist, we are not aware of any other reported case of TC precipitated by amiodarone-induced hyperthyroidism. TC is a relatively new, rare, transient, severe, but reversible cardiovascular condition that is characterized by an acute left ventricular cardiac failure, which can clinically, analytically and electrocardiographically mimic an acute myocardial infarction.Many precipitant factors have been described in TC, being the most classical and emotional trauma. However, thyroid dysfunction is also a significant condition frequently found in patients with TC.A hypercatecholaminergic state leading to cardiomyocyte damage has been established as the main fact of TC physiopathology. Hyperthyroidism induces an upregulation of β-adrenergic receptors.Both hyperthyroidism and hypothyroidism have been related with TC development. Most reported cases of TC involving thyroid dysfunction correspond to hyperthyroidism due to Graves-Basedow disease, but there are also descriptions with severe hypothyroidism, radioiodine treatment or thyroid surgery.Amiodarone is a class III antiarrhythmic agent widely used, and it is a well-known cause of thyroid

  10. DKA-Induced Takotsubo Cardiomyopathy in Patient with Known HOCM

    Directory of Open Access Journals (Sweden)

    Ayla Gordon

    2017-01-01

    Full Text Available The first published case of Diabetic Ketoacidosis-induced Takotsubo cardiomyopathy was in 2009. Our patient is the 1st reported case of Diabetic Ketoacidosis- (DKA- induced Takotsubo cardiomyopathy (TC in a patient with known hypertrophic cardiomyopathy (HOCM in the United States. In the literature, there are only two examples linking DKA to TC; however, this report focuses on the biochemical and physiological causes of TC in a patient with known HOCM and new-onset DKA. TC in previously diagnosed HOCM poses particular complications. With the above patient’s baseline outflow tract obstruction due to septal hypertrophy, the acute reduction in EF due to TC resulted in transient drop in brain perfusion and, therefore, syncope.

  11. Brain resting state functional magnetic resonance imaging in patients with takotsubo cardiomyopathy an inseparable pair of brain and heart.

    Science.gov (United States)

    Sabisz, A; Treder, N; Fijałkowska, M; Sieminski, M; Fijałkowska, J; Naumczyk, P; Nowak, R; Jaguszewski, M; Cwalina, N; Gruchała, M; Szurowska, E; Fijałkowski, M

    2016-12-01

    Takotsubo cardiomyopathy (TTC) is often triggered by emotional or physical stress factors. Psychological variables can have an impact on the physical manifestations of heart disease. TTC may reflect stunned myocardium from a neurogenic source. Anatomical connections between different parts of the brain can be visualized by diffusion tensor imaging (DTI) and thus, expressed by diffusion coefficient - fractional anisotropy (FA). A novel tool used to evaluate brain function in the absence of task is resting state functional magnetic resonance imaging (RS-fMRI). The study included both psychological tests and RS-fMRI examination, and was performed uniformly, in patients with takotsubo and healthy controls. The final group of patients consisted of 13 women, each who underwent a typical pattern of TTC triggered by emotionally stressful factors. The control group included thirteen healthy, age-matched women. Psychological tests revealed that the Type D personality was not more likely to appear among studied patients with takotsubo cardiomyopathy than amongst the healthy population. However, the level of anxiety seen in patients with TTC was increased. There were no differences in FA values between patients and healthy controls. RS-fMRI showed that TTC patients had increased connectivity areas in the precuneus. The healthy controls, when compared to TTC patients had increased connectivity in the ventromedial prefrontal cortex. Taking into account the RS-fMRI results, psychological testing may suggest that TTC patients place a greater focus on themselves (increased tendency to experience negative affectivity, greater conscientiousness) and might have problems with emotional control. Our findings lead to the hypothesis that there is a personality profile for TTC patients' reactions to stressful triggers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Takotsubo Cardiomyopathy in the Setting of Tension Pneumothorax

    Directory of Open Access Journals (Sweden)

    Michael Gale

    2015-01-01

    Full Text Available Background. Takotsubo cardiomyopathy is defined as a transient left ventricular dysfunction, usually accompanied by electrocardiographic changes. The literature documents only two other cases of Takotsubo cardiomyopathy in the latter setting. Methods. A 78-year-old female presented to the ED with severe shortness of breath, hypertension, and tachycardia. On physical exam, heart sounds (S1 and S2 were regular and wheezing was noticed bilaterally. We found laboratory results with a WBC of 20.0 (103/μL, troponin of 16.52 ng/mL, CK-mb of 70.6%, and BNP of 177 pg/mL. The patient was intubated for acute hypoxemic respiratory failure. A chest X-ray revealed a large left-sided tension pneumothorax. Initial echocardiogram showed apical ballooning with a LVEF of 10–15%. A cardiac angiography revealed normal coronary arteries with no coronary disease. After supportive treatment, the patient’s condition improved with a subsequent echocardiogram showing a LVEF of 60%. Conclusion. The patient was found to have Takotsubo cardiomyopathy in the setting of a tension pneumothorax. The exact mechanisms of ventricular dysfunction have not been clarified. However, multivessel coronary spasm or catecholamine cardiotoxicity has been suggested to have a causative role. We suggest that, in our patient, left ventricular dysfunction was induced by the latter mechanism related to the stress associated with acute pneumothorax.

  13. Takotsubo cardiomyopathy: A known unknown foe of asthma.

    Science.gov (United States)

    Kotsiou, Ourania S; Douras, Alexandros; Makris, Demosthenes; Mpaka, Nikoleta; Gourgoulianis, Konstantinos I

    2017-10-01

    Patients with uncontrolled asthma are at a greater risk of asthma attacks requiring emergency room visits or hospital admissions. Takotsubo cardiomyopathy is potentially a significant complication in a course of status asthmaticus. We describe a 43-year-old female patient who presented with status asthmaticus that was further complicated with takotsubo cardiomyopathy. Recognizing apical ballooning syndrome is challenging in patients with a history of respiratory disease because the symptoms of the last entity may complicate the diagnostic approach. It is difficult to distinguish clinically apical ballooning syndrome from the acute airway exacerbation itself. Both asthma and takotsubo cardiomyopathy share the same clinical presentation with dyspnea and chest tightness. In our patient, the electrocardiographic abnormalities, the rapidly reversible distinctive characteristics of echocardiography, and the modest elevation of serum cardiac biomarkers levels, in combination with the presence of a stress trigger (severe asthma attack), strongly supported the diagnosis of broken heart syndrome. Clinicians should re-evaluate asthma management and be aware of the complications associated with asthma attacks such as stress-induced cardiomyopathy.

  14. Psychological Features of Takotsubo Cardiomyopathy: Report of Four Cases.

    Science.gov (United States)

    Jenab, Yaser; Hashemi, Seyedeh Roghaieh; Ghaffari-Marandi, Neda; Zafarghandi, Hoda; Shahmansouri, Nazila

    2017-04-01

    Takotsubo or stress-induced cardiomyopathy is a cardiomyopathy in which the patient has a sudden onset, reversible left ventricular systolic dysfunction without any significant coronary artery disease. Four women, who were at a mean age of 64 years and suffered from chest pain exacerbated by emotional stress, were admitted as cases of acute coronary syndrome and were completely evaluated through precise history taking, physical examination, and ECG. Coronary angiography or coronary multidetector computed tomography was used to exclude significant coronary artery disease. In these patients with confirmed Takotsubo cardiomyopathy, in addition to the Diagnostic and Statistical Manual of the American Psychiatric Association (DSM-IV) criteria, a 71-item form of the Minnesota Multiphasic Personality Inventory (MMPI)-Mini-Mult-was employed for psychological assessment. The main common elevated scale was hypochondriasis. Individuals with high scores on this scale are obsessed with themselves, especially in regard to their body, and often use their disease symptoms in order to manipulate others. They are mainly passive aggressive, critical, and demanding, which stems from their lack of effective verbal abilities as a means of communication, specifically when it comes to anger or hostility expression. To the best of our knowledge, there is no available study evaluating patients with Takotsubo cardiomyopathy using the Mini-Mult questionnaire for psychological assessment.

  15. Women's experiences of Takotsubo cardiomyopathy in a short-term perspective--a qualitative content analysis.

    Science.gov (United States)

    Dahlviken, Rønnaug M; Fridlund, Bengt; Mathisen, Lars

    2015-06-01

    Takotsubo cardiomyopathy is a reversible condition mimicking acute myocardial infarction. The phenomenon is associated with emotional and physical stressful trigger events. Evidence-based patient counselling should be based on disease-specific knowledge of patient experiences. The aim of the study was to describe women's experiences of Takotsubo cardiomyopathy in a short-term perspective. The study design was explorative and descriptive. Semi-structured interviews were conducted with 14 women diagnosed with Takotsubo cardiomyopathy, 1 day to 9 months after hospitalisation. The transcriptions underwent qualitative content analysis. The main theme that emerged was Takotsubo cardiomyopathy as a continuous process of making sense and adapting. To begin with, understanding and coping with signs and symptoms were described as having a diversity of signs and symptoms, taking actions towards signs and symptoms, receiving treatment for suspected ST/non ST-elevation myocardial infarction diagnosis and finally being diagnosed with Takotsubo cardiomyopathy. Understanding the context of illness was expressed as getting treated for Takotsubo cardiomyopathy diagnosis and having previous stressful conditions of life. The changing perspective that emanated was a combination of having prospects and expectations and experiencing limitations. Finally, managing to live with Takotsubo cardiomyopathy was manifested as returning home with the illness and receiving follow-up health care. Information on regaining prior health status and capacity within a short-term perspective may not be accurate. These women struggle and require education and counselling from healthcare professionals to comprehend and manage having a Takotsubo cardiomyopathy diagnosis. Women experiencing Takotsubo cardiomyopathy may be a target group for holistic and individual health care with a longer duration of follow-up. © 2014 Nordic College of Caring Science.

  16. Next Generation Inverter

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Zilai [General Motors LLC, Detroit, MI (United States); Gough, Charles [General Motors LLC, Detroit, MI (United States)

    2016-04-22

    The goal of this Cooperative Agreement was the development of a Next Generation Inverter for General Motors’ electrified vehicles, including battery electric vehicles, range extended electric vehicles, plug-in hybrid electric vehicles and hybrid electric vehicles. The inverter is a critical electronics component that converts battery power (DC) to and from the electric power for the motor (AC).

  17. Y-source inverter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Town, Graham; Loh, Poh Chiang

    2014-01-01

    This paper introduces a new 3-phase Y-source inverter whose gain is presently not matched by classical impedance-network-based inverters operating at the same duty ratio. The proposed network uses a tightly coupled transformer with three windings. By squeezing the shoot-through range while keeping...

  18. Modular inverter system

    Science.gov (United States)

    Ma, Mingyao; Hu, Haibing; Kutkut, Nasser; Batarseh, Issa; Shen, John; , Bkayrat, Raed

    2017-08-01

    A system connected to an AC power grid having an AC phase signal includes an inverter module including a first inverter coupled to a DC voltage, actuated based on the AC phase signal. The first inverter provides a first voltage signal having predetermined harmonic components. A second inverter includes second switch elements coupled to the DC voltage and actuated by a second set of control signals phase delayed with respect to the first control signals. A transformer module has first and second primary windings coupled to the first and second inverters. The transformer module further includes a secondary winding coupled to first primary winding, the second primary winding, and the AC power grid. The secondary winding is configured to provide a secondary output voltage to the AC power grid by combining the first voltage signal and the second voltage signal such that the predetermined harmonic components are substantially cancelled.

  19. Cardiomiopatia de takotsubo como causa de disfunção ventricular transitória Takotsubo cardiomyopathy causing transitory ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Angele A. Alves

    2008-03-01

    Full Text Available Relato do caso de mulher de 74 anos, com hipertensão arterial sistêmica e insuficiência vascular periférica, que apresentou sintomas de síndrome coronariana aguda. A angiografia coronariana demonstrou artérias sem obstruções significativas. A ventriculografia e a ecocardiografia demonstraram acinesia dos segmentos médios e apicais, e hipercinesia dos segmentos basais do ventrículo esquerdo. A paciente evoluiu com recuperação completa da função global e motilidade segmentar em ecocardiografia realizada duas semanas após o início dos sintomas. Esse padrão incomum e reversível de disfunção sistólica e comprometimento segmentar dando ao ventrículo esquerdo forma semelhante a um takotsubo é hoje conhecido como cardiomiopatia do estresse.This is the report of a 74-year-old female patient with a history of systemic hypertension and peripheral vascular disease who presented acute coronary syndrome symptoms. Coronary angiography showed coronary arteries with no significant obstructions. Ventriculography and echocardiography showed akinesia in mid and apical segments; and hyperkinesia of left ventricle basal segments. Two weeks after the onset of symptoms, a new echocardiogram demonstrated normal global and regional systolic function. The uncommon, reversible pattern for systolic dysfunction and segmental compromising that gives left ventricle a takostubo-like shape is known today as stress cardiomyopathy.

  20. Psychological disorders in adults with inherited cardiomyopathies and Takotsubo syndrome

    Directory of Open Access Journals (Sweden)

    Mariana Suárez Bagnasco

    2016-06-01

    Full Text Available Realizamos una revisión narrativa sobre trastornos psicológicos en adultos con diagnóstico de síndrome de Takotsubo y miocardiopatías hereditarias. Utilizando las bases de datos PubMed y PsycINFO buscamos los trabajos relevantes publicados entre 2000 y 2015. Encontramos doce estudios que exploran alteraciones psicológicas en síndrome de Takotsubo y ocho estudios sobre miocardiopatías hereditarias: cinco enrolaron pacientes con miocardiopatía hipertrófica, dos miocardiopatía dilatada, uno miocardiopatía arritmogénica del ventrículo derecho. Todas las publicaciones reportaron la presencia de trastornos psicológicos. En el síndrome de Takotsubo, la depresión oscila entre el 20,5 y el 48% y la ansiedad estuvo presente entre el 26 y el 56%. Un estudio reporta que la ansiedad aumenta la probabilidad de desarrollar el síndrome de Takotsubo. En la miocardiopatía dilatada, la ansiedad estuvo presente en el 50% de los pacientes y la depresión en el 22%. En la miocardiopatía arritmogénica del ventrículo derecho, la edad más joven, peor capacidad funcional y haber experimentado al menos un shock por desfibrilador automático implantable, fueron predictores independientes significativos de ansiedad tanto específica por el dispositivo como generalizada. En la miocardiopatía hipertrófica, la ansiedad y la depresión estaban presentes en 45,2% y 17,9%, respectivamente. Treinta y siete por ciento cumplía con los criterios de diagnóstico para los trastornos de ansiedad y 21% para los trastornos del estado de ánimo. Cerca de la mitad de los pacientes con miocardiopatía hipertrófica informan dolor en el pecho, disnea y mareos desencadenados por estrés emocional. Debido al reducido número de estudios publicados, las conclusiones son limitadas. No obstante, presentamos algunos de los resultados.

  1. FOLFOX Induced Takotsubo Cardiomyopathy Treated with Impella Assist Device

    Directory of Open Access Journals (Sweden)

    Swethika Sundaravel

    2017-01-01

    Full Text Available Chemotherapy induced cardiotoxicity is becoming increasingly prevalent with several new agents being used recently. The incidence of Takotsubo cardiomyopathy due to 5-fluorouracil based chemotherapeutic regimens like FOLFOX is not uncommon. It is also seen with platinum based chemotherapy. Most of these patients have reversible cardiotoxicity and the cardiac function recovers within a short period with supportive treatment. Here we have a patient who presented with cardiogenic shock after 5 days of receiving FOLFOX regimen for colorectal adenocarcinoma. She was treated with a percutaneous left ventricular assist device, Impella CP, for hemodynamic support with excellent outcome.

  2. Clinical features and outcome of epinephrine-induced takotsubo syndrome: Analysis of 33 published cases

    Energy Technology Data Exchange (ETDEWEB)

    Y-Hassan, Shams, E-mail: shams.younis-hassan@karolinska.se

    2016-10-15

    Background: Takotsubo syndrome (TS) may be triggered by innumerable physical stress factors including epinephrine administration. The aim of this study is to report on the clinical features and outcome of epinephrine-induced TS (Epi-TS) in a large cohort of published cases. Methods: A computer assisted search of the electronic data base Pubmed was performed from 1990 to 2014. All cases deemed to have Epi-TS were retrieved and compared to the large recent report by Templin et al. (All-TS). Results: Thirty-three cases of Epi-TS were retrieved from the literature and compared to 1750 cases of All-TS. Chest pain as a presenting symptom occurred in 45% of cases. The Epi-TS patients were on average 20.6 years younger than All-TS patients (p < 0.0001). The women were still predominating in Epi-TS but in a significantly lower percentage compared to ALL-TS (73% in Epi-TS vs 89.8% in All-TS, p = 0.0054). One third of the Epi-TS cases had basal pattern of TS compared to 2.2% of cases reported in All-TS. Epi-TS cases were characterized by high complication rates, which occurred in 57.6%. The most important risk factor for the development of TS complication was the accidental administration (P < 0.001) and the dose of >1 mg epinephrine (p = 0.02). In spite of high complication rates, the recovery was rapid with no in-hospital mortality. Conclusion: Epi-TS is characterized by a dramatic rapid onset of symptoms after epinephrine administration. Almost half of the cases had apical sparing and one third basal pattern of TS. In spite of high complication rates, the prognosis was good with no in-hospital mortality. - Highlights: • Published cases of Epinephrine-induced Takotsubo Syndrome (Epi-TS) are reviewed. • Epi-TS is characterized by a dramatic clinical presentation and high complication rates. • In spite of high complication rates, the prognosis of Epi-TS is good. • Almost half of the cases of Epi-TS had apical sparing pattern of TS. • The implications of the findings

  3. Clinical features and outcome of epinephrine-induced takotsubo syndrome: Analysis of 33 published cases

    International Nuclear Information System (INIS)

    Y-Hassan, Shams

    2016-01-01

    Background: Takotsubo syndrome (TS) may be triggered by innumerable physical stress factors including epinephrine administration. The aim of this study is to report on the clinical features and outcome of epinephrine-induced TS (Epi-TS) in a large cohort of published cases. Methods: A computer assisted search of the electronic data base Pubmed was performed from 1990 to 2014. All cases deemed to have Epi-TS were retrieved and compared to the large recent report by Templin et al. (All-TS). Results: Thirty-three cases of Epi-TS were retrieved from the literature and compared to 1750 cases of All-TS. Chest pain as a presenting symptom occurred in 45% of cases. The Epi-TS patients were on average 20.6 years younger than All-TS patients (p < 0.0001). The women were still predominating in Epi-TS but in a significantly lower percentage compared to ALL-TS (73% in Epi-TS vs 89.8% in All-TS, p = 0.0054). One third of the Epi-TS cases had basal pattern of TS compared to 2.2% of cases reported in All-TS. Epi-TS cases were characterized by high complication rates, which occurred in 57.6%. The most important risk factor for the development of TS complication was the accidental administration (P < 0.001) and the dose of >1 mg epinephrine (p = 0.02). In spite of high complication rates, the recovery was rapid with no in-hospital mortality. Conclusion: Epi-TS is characterized by a dramatic rapid onset of symptoms after epinephrine administration. Almost half of the cases had apical sparing and one third basal pattern of TS. In spite of high complication rates, the prognosis was good with no in-hospital mortality. - Highlights: • Published cases of Epinephrine-induced Takotsubo Syndrome (Epi-TS) are reviewed. • Epi-TS is characterized by a dramatic clinical presentation and high complication rates. • In spite of high complication rates, the prognosis of Epi-TS is good. • Almost half of the cases of Epi-TS had apical sparing pattern of TS. • The implications of the findings

  4. Hypertrophic Obstructive Cardiomyopathy Masked by Tako-Tsubo Syndrome: A Case Report

    Directory of Open Access Journals (Sweden)

    Y. Daralammori

    2012-01-01

    Full Text Available Introduction. Left ventricular outflow obstruction might be part of the pathophysiological mechanism of Tako-tsubo cardiomyopathy. This obstruction can be masked by Tako-tsubo cardiomyopathy and diagnosed only by followup. Case Presentation. A 70-year-old female presented with Tako-tsubo cardiomyopathy and masked obstructive hypertrophic cardiomyopathy at presentation. Conclusion. Tako-tsubo cardiomyopathy typically presents like an acute MI and is characterized by severe, but transient, regional left ventricular systolic dysfunction. Prompt evaluation of the coronary status is, therefore, mandatory. The prognosis under medical treatment of heart failure symptoms and watchful waiting is favourable. Previous studies showed that LVOT obstruction might be part of the pathophysiological mechanism of TCM. This paper supports this theory. However, TCM may also mask any preexisting LVOT obstruction.

  5. Acute Pulmonary Edema in an Eclamptic Pregnant Patient: A Rare Case of Takotsubo Syndrome.

    Science.gov (United States)

    Karamchandani, Kunal; Bortz, Brandon; Vaida, Sonia

    2016-09-23

    BACKGROUND Acute pulmonary edema in a pregnant patient is associated with significant morbidity and mortality. Takotsubo syndrome, or stress-induced cardiomyopathy, is a rare cause of acute pulmonary edema in a pregnant patient, especially prior to delivery of the fetus. CASE REPORT We describe a case of a pregnant patient who presented with acute pulmonary edema and eclampsia and was found to have Takotsubo syndrome. To the best of our knowledge, eclampsia as a precipitating factor for Takotsubo syndrome has not been described in literature. CONCLUSIONS Clinicians taking care of pregnant patients should be aware of the potential link between eclampsia and Takotsubo cardiomyopathy. Prompt correction of the precipitating cause along with supportive management as described is the key to a successful outcome.

  6. Multilevel DC link inverter

    Science.gov (United States)

    Su, Gui-Jia

    2003-06-10

    A multilevel DC link inverter and method for improving torque response and current regulation in permanent magnet motors and switched reluctance motors having a low inductance includes a plurality of voltage controlled cells connected in series for applying a resulting dc voltage comprised of one or more incremental dc voltages. The cells are provided with switches for increasing the resulting applied dc voltage as speed and back EMF increase, while limiting the voltage that is applied to the commutation switches to perform PWM or dc voltage stepping functions, so as to limit current ripple in the stator windings below an acceptable level, typically 5%. Several embodiments are disclosed including inverters using IGBT's, inverters using thyristors. All of the inverters are operable in both motoring and regenerating modes.

  7. Postoperative Takotsubo cardiomyopathy triggered by intraoperative fluid overload and acute hypertensive crisis.

    Science.gov (United States)

    Varutti, Rosanna; Setti, Tommaso; Ezri, Tiberiu; Nicolosi, Gianluigi; Rellini, Gianluigi; Cassin, Matteo; Leykin, Yigal

    2015-04-01

    The Takotsubo cardiomyopathy is a rare haemodynamic dysfunction, only recently reported perioperatively. While the diagnostic criteria have been established and the outcome is known as favorable, the pathophysiological mechanisms are not entirely understood. Here we present the case of a patient scheduled for laparoscopic hysterectomy and adnexectomy, who early postoperatively developed a Takotsubo cardiomyopathy supposedly triggered by an acute hypertensive crisis due to intraoperative fluid overload.

  8. Reliable inverter systems

    Science.gov (United States)

    Nagano, S.

    1979-01-01

    Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

  9. Climatic variables in Takotsubo cardiomyopathy: role of temperature.

    Science.gov (United States)

    Novo, Giuseppina; Mariano, Enrica; Giambanco, Salvatore; Bonomo, Vito; Manno, Girolamo; Viele, Annalisa; Evola, Salvatore; Giambanco, Francesco; Assennato, Pasquale; Novo, Salvatore; Romeo, Francesco

    2017-03-01

    Recent studies documented a seasonal (summer) and circadian (morning) temporal distribution of takotsubo cardiomyopathy (TTC). The aim of our study was to investigate whether there is a relationship among season, temperature and the occurrence of TTC. A second aim of our study was the comparison of climatic variables in Takotsubo cardiomyopathy versus acute myocardial infarction (AMI). We enrolled consecutive patients with TTC in three Italian centres and, for comparison consecutive patients with AMI. The frequency of TTC and AMI patients according to month, season and quartiles of temperature (I quartile: 9.8-15°, II quartile: 15-19°, III quartile: 19-25° and IV quartile: 25-38°C) was reported. Climatic variables of TTC and AMI patients were compared. We included in the study 85 patients with TTC and 900 patients with AMI. It was not observed a significant peak in the occurrence of TTC during summer time; however, when compared with AMI, TTC was more frequent in summer. We found an absolute higher frequency of TTC cases with warmer temperatures. TTC cases occurred during warmer temperatures than AMI. Our study does not confirm a summer preference for TTC occurrence, as reported by previous studies, even if, compared with AMI, TTC is more frequent in summer. During warmest days, it was recorded the highest incidence of TTC.

  10. Takotsubo syndrome and brachydactyly: a new heart-hand syndrome?

    Science.gov (United States)

    Danese, C; Bocchini, S; Rubini, G; Nardi, M; Amato, S

    2011-01-01

    The Takotsubo syndrome (TTS) is a transient myocardic hypoadyskinesis so called for its typically aspect like the cages used by Japanese fisherman to trap octopus. Presently, several etiologies were considered for the development of TTS, the most accredited ones suggest that stress, adrenoreceptor hyperactivity and estrogens are the most important causes of transient morphofunctional alterations of left ventricle. We describe the case of 60 year-old woman with a chest pain occurred after a quarrel. Because of this, she went to the Emergency Department (ED) where T wave flat in lead D-I, increase of CK-MB mass and Troponin I were found. Subsequently, a coronary-ventriculography was performed and a diagnosis of Takotsubo syndrome was made. Also a bilateral IV toe brachydactyly was noted. In medical literature, there are many syndromes described about the association between skeletal alteration of the hands and heart abnormalities (heart-hand syndrome). The Authors wonder if this case can belong to this kind of complex malformations as well as if a molecular-genetic trait can link the two clinical aspects.

  11. Spontaneous coronary artery dissection and takotsubo syndrome: An often overlooked association; review.

    Science.gov (United States)

    Y-Hassan, Shams

    2018-02-08

    Spontaneous coronary artery dissection (SCAD) and takotsubo syndrome (TS) are two cardiovascular syndromes with predilection for women. Both conditions may be preceded by an emotional stress or, for the affected individual, an unusual severe physical exercise. "Restitution ad integrum" occurs in most cases suffering from SCAD or TS with complete angiographic resolution of the dissected vessel and left ventricular dysfunction respectively. Recently, many cases, which were initially diagnosed as TS because of typical left ventricular ballooning pattern showed to have SCAD, have been reported; these cases were deemed to be "SCAD misdiagnosed as TS". The left ventricular wall motion abnormality has been attributed to the ischemia caused by SCAD-affected coronary vessel especially in the left anterior descending artery (LAD) with "wrap-around course". However, the left ventricular ballooning pattern have occurred in patients with SCAD in non-long-wrap-around LAD and SCAD in other coronary branches where coronary ischemia on its own cannot explain the left ventricular ballooning. In this review, sufficient data supporting the evidence for the possibility of coexistence of SCAD and TS is provided. Misdiagnosis of the association of the two conditions may result in mismanagement of the patient with undesirable consequences. Furthermore, the causal links between SCAD and TS is discussed. Copyright © 2018. Published by Elsevier Inc.

  12. Broken heart as work-related accident: Occupational stress as a cause of takotsubo cardiomyopathy in 55-year-old female teacher - Role of automated function imaging in diagnostic workflow.

    Science.gov (United States)

    Mielczarek, Agnieszka; Kasprzak, Jarosław Damian; Marcinkiewicz, Andrzej; Kurpesa, Małgorzata; Uznańska-Loch, Barbara; Wierzbowska-Drabik, Karina

    2015-01-01

    Takotsubo cardiomiopathy (TTC) (known also as "ampulla cardiomyopathy," "apical ballooning" or "broken heart syndrome") is connected with a temporary systolic left ventricular dysfunction without the culprit coronary lesion. Takotsubo cardiomyopathy was first described in 1990 in Japan after octopus trapping pot with a round bottom and narrow neck similar in shape to left ventriculogram in TTC patients. The occurrence of TTC is usually precipitated by a stressful event with a clinical presentation mimicking myocardial infarction: chest pain, ST-T segment elevation or T-wave inversion, a rise in cardiac troponin, and contractility abnormalities in echocardiography. A left ventricular dysfunction is transient and improves within a few weeks. Takotsubo cardiomyopathy typically occurs in postmenopausal women and the postulated mechanism is catecholamine overstimulation. Moreover, the distribution of contractility impairments usually does not correspond with typical region supplied by a single coronary artery. Therefore, the assessment of regional pattern of systolic dysfunction with speckle-tracking echocardiography and automated function imaging (AFI) technique may be important in diagnosis of TTC and may improve our insight into its patophysiology. We described a 55-year-old female teacher with TTC diagnosed after acute psychological stress in workplace. The provoking factor related with occupational stress and pattern of contraction abnormalities documented with AFI technique including basal segments of left ventricle make this case atypical. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Broken heart as work-related accident: Occupational stress as a cause of takotsubo cardiomyopathy in 55-year-old female teacher – Role of automated function imaging in diagnostic workflow

    Directory of Open Access Journals (Sweden)

    Agnieszka Mielczarek

    2015-12-01

    Full Text Available Takotsubo cardiomiopathy (TTC (known also as “ampulla cardiomyopathy,” “apical ballooning” or “broken heart syndrome” is connected with a temporary systolic left ventricular dysfunction without the culprit coronary lesion. Takotsubo cardiomyopathy was first described in 1990 in Japan after octopus trapping pot with a round bottom and narrow neck similar in shape to left ventriculogram in TTC patients. The occurrence of TTC is usually precipitated by a stressful event with a clinical presentation mimicking myocardial infarction: chest pain, ST-T segment elevation or T-wave inversion, a rise in cardiac troponin, and contractility abnormalities in echocardiography. A left ventricular dysfunction is transient and improves within a few weeks. Takotsubo cardiomyopathy typically occurs in postmenopausal women and the postulated mechanism is catecholamine overstimulation. Moreover, the distribution of contractility impairments usually does not correspond with typical region supplied by a single coronary artery. Therefore, the assessment of regional pattern of systolic dysfunction with speckle-tracking echocardiography and automated function imaging (AFI technique may be important in diagnosis of TTC and may improve our insight into its patophysiology. We described a 55-year-old female teacher with TTC diagnosed after acute psychological stress in workplace. The provoking factor related with occupational stress and pattern of contraction abnormalities documented with AFI technique including basal segments of left ventricle make this case atypical.

  14. Resonant snubber inverter

    Science.gov (United States)

    Lai, J.S.; Young, R.W. Sr.; Chen, D.; Scudiere, M.B.; Ott, G.W. Jr.; White, C.P.; McKeever, J.W.

    1997-06-24

    A resonant, snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the main inverter switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter. 14 figs.

  15. Resonant snubber inverter

    Science.gov (United States)

    Lai, Jih-Sheng; Young, Sr., Robert W.; Chen, Daoshen; Scudiere, Matthew B.; Ott, Jr., George W.; White, Clifford P.; McKeever, John W.

    1997-01-01

    A resonant, snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the main inverter switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.

  16. SEEPAGE/INVERT INTERACTIONS

    International Nuclear Information System (INIS)

    P.S. Domski

    2000-01-01

    As directed by a written development plan (CRWMS M andO 1999a), a conceptual model for water entering the drift and reacting with the invert materials is to be developed. The purpose of this conceptual model is to assist Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department in modeling the geochemical environment within a repository drift, thus allowing PAO to provide a more detailed and complete in-drift geochemical model abstraction, and to answer the key technical issues (KTI) raised in the NRC Issue Resolution Status Report (IRSR) for the Evolution of the Near-Field Environment (NFE), Revision 2 (NRC 1999). This AMR also seeks to: (1) Develop a logical conceptual model for physical/chemical interactions between seepage and the invert materials; (2) screen potential processes and reactions that may occur between seepage and invert to evaluate the potential consequences of the interactions; and (3) outline how seepage/invert processes may be quantified. This document provides the conceptual framework for screening out insignificant processes and for identifying and evaluating those seepage/invert interactions that have the potential to be important to subsequent PAO analyses including the Engineered Barrier System (EBS) physical and chemical model abstraction effort. This model has been developed to serve as a basis for the in-drift geochemical analyses performed by PAO. Additionally, the concepts discussed within this report may also apply to certain near and far-field geochemical processes and may have conceptual application within the unsaturated zone (UZ) and saturated zone (SZ) transport modeling efforts. The seepage/invert interactions will not directly affect any principal factors

  17. Self-reported symptoms 8weeks after discharge: A comparison of takotsubo syndrome and myocardial infarction.

    Science.gov (United States)

    Wallström, Sara; Ulin, Kerstin; Omerovic, Elmir; Ekman, Inger

    2016-12-01

    Takotsubo syndrome is a form of acute, reversible heart failure that has gained increasing attention. It affects mostly postmenopausal women, and its acute onset and symptoms mimic acute myocardial infarction. The distinct feature of takotsubo syndrome is the ballooning of a ventricle, but the complete pathophysiological mechanisms are not fully understood. Both short-term and long-term survival are affected, but little is known about the illness experience and self-reported residual symptoms after discharge from hospital. To measure and compare self-reported residual symptoms between patients with takotsubo syndrome and those with acute myocardial infarction. Questionnaire data measuring self-reported symptoms were collected from 48 patients with takotsubo syndrome and 79 patients with acute myocardial infarction 8weeks after discharge. A multivariate adjusted complete case regression model was used to compare the frequency and severity of symptoms. Self-reported symptoms 8weeks after discharge differed little between patients with takotsubo syndrome and those with acute myocardial infarction. Both groups reported symptoms, including pain, fatigue, breathlessness, and sleep disturbance. At onset there were significant differences between the groups concerning previous diabetes mellitus, cardiac troponin T, ejection fraction and Killip class. There were no significant between-group differences in frequency or severity of symptoms after adjusting for these differences. Patients with takotsubo syndrome experience residual symptoms after discharge. Symptoms in several cardiovascular diseases predict quality of life, re-admission, and mortality. Symptom management should be integrated into follow-up care for patients with takotsubo syndrome. One way of achieving this is through person-centered care. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Takotsubo Cardiomyopathy in a Patient with Undiscovered Sigmoid Colon Cancer

    Directory of Open Access Journals (Sweden)

    Huang Po-Yen

    2017-01-01

    Full Text Available Takotsubo cardiomyopathy (TTC is a stress-related cardiomyopathy that is characterized by reversible left systolic dysfunction, which appears to be precipitated by sudden emotional or physical stress in the absence of myocardial infarction. Here we present a rare case that clinically presented with intermittent abdominal pain, initially impressed as non-ST elevation myocardial infarction and congestive heart failure but with a normal coronary angiogram. Her symptoms relieved spontaneously without returning. Sigmoid colon cancer was diagnosed via colonoscopy later due to persistent abdominal discomfort. In the absence of detectable emotional or physical stress factors, the newly diagnosed sigmoid colon cancer was the only possible trigger factor of TTC. We offer this case as a reminder that cancer should be considered in the differential diagnosis of patients presenting with the etiology of TTC.

  19. Takotsubo cardiomyopathy: The challenging diagnosis in clinical routine

    Directory of Open Access Journals (Sweden)

    Eglė Kazakauskaitė

    2014-01-01

    Full Text Available Takotsubo cardiomyopathy is rapidly reversible heart failure syndrome that usually mimics the symptoms of acute myocardial infarction with the characteristic regional wall-motion abnormalities (classically with a virtual apical ballooning caused by hypokinetic or akinetic apical or midventricular myocardium and hypercontraction of the basal segments and absence of obstructive coronary artery disease. TC is usually associated with identifiable emotional, psychological or physical stress event and most commonly appears in postmenopausal women. The certain pathophysiological mechanism remains unknown. However, the central hypothesis is supported by the excess of catecholamines and hyperactivity of nervous system. In the last decades the frequency of the TC diagnosis is increasing rapidly but at the initial presentation the diagnosis remains challenging due to the close similarities between TC and ST elevation myocardial infarction clinical presentations that consider TC as an important part of differential diagnosis in acute coronary syndrome.

  20. Central Nervous System (CNS Disease Triggering Takotsubo Syndrome

    Directory of Open Access Journals (Sweden)

    Josef Finsterer

    2016-01-01

    Full Text Available Takotsubo syndrome (TTS is usually triggered by psychological or physical stress. One of the many physical sources of stress are central nervous system (CNS disorders. CNS disorders most frequently triggering TTS include subarachnoid bleeding, epilepsy, ischemic stroke, migraine, and intracerebral bleeding. More rare CNS-triggers of TTS include posterior reversible encephalopathy syndrome (PRES, amyotrophic lateral sclerosis, encephalitis, or traumatic brain or spinal cord injury. TTS triggered by any of the CNS disorders needs to be recognized since adequate treatment of TTS may improve the general outcome from the CNS disorder as well. Neurologists need to be aware of TTS as a complication of specific CNS disorders but TTS may be triggered also by CNS disorders so far not recognised as causes of TTS.

  1. Immersion Pulmonary Edema in the Setting of Takotsubo Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Tara Reed

    2016-01-01

    Full Text Available Immersion Pulmonary Edema (IPE is a unique medical condition being increasingly described in the medical literature as sudden-onset pulmonary edema in the setting of scuba diving and/or swimming. We report on three patients with unique presentations of IPE with associated development of Takotsubo cardiomyopathy (TTC. All three cases occurred in Oahu, Hawaii and were seen by the same cardiologist within a span of seven years. Each patient was scuba diving with sudden onset dyspnea with pulmonary edema on chest x-ray. Cardiac catheterization revealed no significant epicardial stenosis or thrombosis. EKGs showed typical evolution of symmetric T wave inversion. Wall motion abnormalities resolved. IPE and TTC may occur together and may be more common than initially thought. Physical and emotional stressors are known to trigger TTC. TTC should be considered as a possible complication of IPE. Initial workup should include EKGs, cardiac enzymes, echocardiogram and, in the appropriate situation, cardiac catheterization.

  2. Sepsis-Induced Myocardial Depression and Takotsubo Syndrome

    Directory of Open Access Journals (Sweden)

    Mustafa Kemal Arslantaş

    2015-08-01

    Full Text Available Sepsis induced temporary myocardial dysfunction characterized as impairment of myocardial contraction is an important cause of mortality and morbidity in intensive care units. Takotsubo syndrome (TS is temporary ballooning and dysfunction of the apical part of left ventricle without significant stenosis of coronary arteries. Recently, it was suggested that impairment in regional catecholamine distribution caused by stress factors and excessive cardiac sympathetic activity mechanism play role in sepsis such as other causes of TS. Additionally, vasopressor agents (as noradrenaline which are widely used in sepsis treatment may be triggering factor. Serial case reports of sepsis associated TS are reported, however pathophysiology, diagnosis and treatment strategies of these two different syndromes is not obvious.

  3. Power inverter implementing phase skipping control

    Science.gov (United States)

    Somani, Utsav; Amirahmadi, Ahmadreza; Jourdan, Charles; Batarseh, Issa

    2016-10-18

    A power inverter includes a DC/AC inverter having first, second and third phase circuitry coupled to receive power from a power source. A controller is coupled to a driver for each of the first, second and third phase circuitry (control input drivers). The controller includes an associated memory storing a phase skipping control algorithm, wherein the controller is coupled to receive updating information including a power level generated by the power source. The drivers are coupled to control inputs of the first, second and third phase circuitry, where the drivers are configured for receiving phase skipping control signals from the controller and outputting mode selection signals configured to dynamically select an operating mode for the DC/AC inverter from a Normal Control operation and a Phase Skipping Control operation which have different power injection patterns through the first, second and third phase circuitry depending upon the power level.

  4. Radiological follow-up of inverted papilloma

    Energy Technology Data Exchange (ETDEWEB)

    Petit, P.; Vivarrat-Perrin, L.; Champsaur, P.; Juhan, V.; Chagnaud, C.; Vidal, V.; Gaubert, J.Y.; Bartoli, J.M.; Moulin, G. [Department of Radiology, Groupe Hospitalier de la Timone, Centre Hospitalier et Universitaire de Marseille, F-13385 Marseille Cedex 5 (France); Dessi, P.; Zanaret, M. [Department of Head and Neck Surgery, Groupe Hospitalier de la Timone, Centre Hospitalier et Universitaire de Marseille, F-13385 Marseille Cedex 5 (France)

    2000-07-01

    The aim of this study was to describe cross-sectional imaging features of recurrent papilloma of the nasal fossa and paranasal sinuses and to evaluate the role of MR and CT in the postoperative follow-up of this lesion. Magnetic resonance imaging and CT of ten patients who presented recurrence of inverted papilloma were reviewed and correlated to initial imaging, endoscopy, and surgical reports. Imaging patterns of recurrent inverted papilloma are identical to those of initial tumors and recurrence location is closely related to the site of the former lesion. Magnetic resonance is more efficient than CT for the diagnosis and evaluation of extensions. Magnetic resonance supplies the deficiencies of endoscopy in case of extensions to the frontal sinus or the lateral recess of the antrum, especially if mucosal hyperplasia or sinusitis is associated. Magnetic resonance imaging is the first imaging modality to perform in the follow-up after removal of inverted papilloma. (orig.)

  5. Energy-Saving Inverter

    Science.gov (United States)

    Rippel, W. E.; Edwards, D. B.

    1984-01-01

    Commutation by field-effect transistor allows more efficient operation. High voltage field-effect transistor (FET) controls silicon controlled rectifiers (SCR's). Circuit requires only one capacitor and one inductor in commutation circuit: simpler, more efficient, and more economical than conventional inverters. Adaptable to dc-to-dc converters.

  6. Síndrome do coração partido (síndrome de Takotsubo Broken-heart syndrome (Takotsubo syndrome

    Directory of Open Access Journals (Sweden)

    Alessandra Edna Teófilo Lemos

    2008-01-01

    Full Text Available A cardiopatia induzida por estresse (precipitada por estresse emocional, também chamada de balonamento apical transitório do ventrículo esquerdo, síndrome do coração partido e, no Japão, síndrome de takotsubo, é caracterizada pela presença de movimento discinético transitório da parede anterior do ventrículo esquerdo, com acentuação da cinética da base ventricular. O curso clínico da cardiomiopatia de takotsubo pode se assemelhar ao do infarto agudo do miocárdio, com dor torácica típica e alterações eletrocardiográficas, sendo a cineangiocoronariografia realizada para distinguir as duas condições na fase aguda.Stress-induced cardiomyopathy, also know as reversible left ventricular apical ballooning, " Broken-Heart" syndrome, and in Japan, Takotsubo, is characterized by the presence of a transient left ventricular dyskinetic movement of the anterior wall of with hypercontraction of the ventricular basilar segments precipitated by emotional stress. The clinical course of Takotsubo cardiomyopathy is similar to that of an acute myocardial infarct with typical chest pain and electrocardiographic changes, and during the acute phase, coronary angiography is used to distinguish between the two conditions.

  7. Inverter communications using output signal

    Science.gov (United States)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  8. Síndrome da disfunção apical reversível (Takotsubo Transient ventricular dysfunction (Takotsubo cardiomyopathy

    Directory of Open Access Journals (Sweden)

    José Marconi Almeida de Sousa

    2005-04-01

    Full Text Available Homem portador de miastenia gravis, internado por descompensação da doença de base, em insuficiência respiratória aguda. Na evolução, apresentou quadro sugestivo de infarto agudo do miocárdio, com alterações eletrocardiográficas e enzimáticas compatíveis com o diagnóstico. Submetido a coronariografia de urgência, não evidenciou obstrução coronariana grave, entretanto o ventrículo esquerdo apresentava disfunção sistólica importante, com alteração característica pela ventriculografia da síndrome descrita como disfunção ventricular transitória ou síndrome de Takotsubo. Na evolução, houve completa recuperação das alterações eletrocardiográficas e da função ventricular sistólica avaliada pelo ecocardiograma, confirmando a síndrome.The patient was a male with myasthenia gravis, hospitalized with acute respiratory failure due to decompensation of the underlying disease. He evolved with findings suggestive of acute myocardial infarction, with electrocardiographic and enzymatic alterations compatible with that diagnosis. The patient underwent emergency coronary angiography, which showed no severe coronary obstruction, although his left ventricle had significant systolic dysfunction with characteristic alterations, on ventriculography, of the syndrome described as transient ventricular dysfunction or Takotsubo syndrome. On evolution, complete recovery of the electrocardiographic alterations and systolic ventricular function assessed on echocardiography occurred, confirming the syndrome.

  9. Inverting the Linear Algebra Classroom

    Science.gov (United States)

    Talbert, Robert

    2014-01-01

    The inverted classroom is a course design model in which students' initial contact with new information takes place outside of class meetings, and students spend class time on high-level sense-making activities. The inverted classroom model is so called because it inverts or "flips" the usual classroom design where typically class…

  10. Quasi-Y-source inverter

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    This paper introduces a new inverter topology called a “quasi-Y-source inverter”. The proposed inverter inherits all the advantages of the original Y-source inverter. In addition, the new topology draws continuous current from the source which is required for many renewable sources. It also has dc...

  11. Milliwatt dc/dc Inverter

    Science.gov (United States)

    Mclyman, C. W.

    1983-01-01

    Compact dc/dc inverter uses single integrated-circuit package containing six inverter gates that generate and amplify 100-kHz square-wave switching signal. Square-wave switching inverts 10-volt local power to isolated voltage at another desired level. Relatively high operating frequency reduces size of filter capacitors required, resulting in small package unit.

  12. Takotsubo cardiomyopathy in the case of 72-year-old teacher after work-related psychological stress. Evolution of left ventricular longitudinal strain - Delayed but complete recovery in automated function imaging (AFI).

    Science.gov (United States)

    Wierzbowska-Drabik, Karina; Marcinkiewicz, Andrzej; Hamala, Piotr; Trzos, Ewa; Lipiec, Piotr; Kurpesa, Małgorzata; Kręcki, Radosław; Plewka, Michał; Kasprzak, Jarosław D

    2017-06-19

    Takotsubo cardiomyopathy (TC) is related to a transient systolic dysfunction of left ventricle (LV), accompanied by clinical and electrocardiographic symptoms of myocardial ischemia in the absence of hemodynamically significant coronary artery disease. Takotsubo cardiomyopathy is usually provoked by a psychologically or/and physically stressful event which may be related to occupational activities. Although visually assessed evolution of LV function is well documented, the data concerning strain changes is sparse and various patterns of deformation abnormalities are suggested. We have described a 72-year-old woman with chest pain related to a lecture given at the meeting of the Senior University, fulfilling all the Mayo Clinic criteria of the TC. The longitudinal strain analysis with automated function imaging (AFI) documented severe impairment and stepwise recovery of regional and global LV contractility. The case described confirms that accurate diagnosis, treatment and documenting of functional improvement in takotsubo cardiomyopathy may enable the return to occupational activities even for elderly persons. Int J Occup Med Environ Health 2017;30(4):681-683. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Inverter ratio failure detector

    Science.gov (United States)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  14. On Stability of Voltage Source Inverters in Weak Grids

    DEFF Research Database (Denmark)

    Adib, Aswad; Mirafza, Behrooz; Wang, Xiongfei

    2018-01-01

    of circuit and control parameters on the stability of voltage source inverters are studied using a small-signal state-space model in the synchronously rotating dq-frame of reference. The full order state-space model developed in this work is directly extracted from Pulse-Width Modulation (PWM) switching......As the number of inverters increases in the power grid, the stability of grid-tied inverters becomes an important concern for the power industry. In particular, a weak grid can lead to voltage fluctuations at the inverter terminals and consequently cause inverter instability. In this paper, impacts...... pattern, and enables the stability analysis of concurrent variations in the three-phase circuit and control parameters. This paper demonstrates that the full-order model of a grid-tied PQ-controlled VSI can be significantly reduced to a second-order model, preserving the overall system stability in case...

  15. Impact of long-term stress in Takotsubo syndrome: Experience of patients.

    Science.gov (United States)

    Wallström, Sara; Ulin, Kerstin; Määttä, Sylvia; Omerovic, Elmir; Ekman, Inger

    2016-12-01

    The connection between stress and disease has been part of folk wisdom for a long time and has even made its way into our language with phrases such as 'scared to death' and 'a broken heart'. Takotsubo syndrome is a form of acute, reversible heart failure characterized by ballooning of the left ventricle. Post-menopausal women are primarily affected, but cases have been described in both sexes and at all ages. The complete pathophysiology is unknown, but the disease has been connected to psychological or physical stress and a surge in catecholamines. Despite the strong connection with stress, knowledge about the life of patients before the onset of Takotsubo syndrome is lacking. The aim of this study was to describe and interpret patients' narratives about long-term stress experienced before the onset of Takotsubo syndrome. Nineteen people diagnosed with Takotsubo syndrome were interviewed. The narrative interviews were recorded and transcribed verbatim. The resulting texts were analysed using phenomenological hermeneutics. The analysis revealed that the interviewees lived under stressful circumstances, characterized by feeling burdened by responsibilities, injustice and uncertainty, long before the onset of Takotsubo syndrome. This long-term stress wore down the defences of the interviewees to the degree that their capacity was exhausted and the smallest stressor could 'tip them over the edge'. The findings indicated that the social structure of gender possibly contributed to the interviewees' condition. These findings indicated that long-term stressful circumstances may cause vulnerability to acute psychological or physical stressors and, subsequently, to the onset of Takotsubo syndrome. © The European Society of Cardiology 2015.

  16. Síndrome de takotsubo após hemorragia subaracnoidea

    Directory of Open Access Journals (Sweden)

    Eduardo Wajnberg

    2012-04-01

    Full Text Available A síndrome de takotsubo corresponde a uma cardiomiopatia caracterizada por uma disfunção miocárdica transitória afetando ápice do ventrículo esquerdo, que classicamente ocorre após grande estresse físico ou emocional (também chamada "síndrome do coração partido" ou "cardiomiopatia induzida por estresse". Descrevemos a ocorrência de síndrome de takotsubo em uma paciente induzida por hemorragia subaracnoidea.

  17. Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    C. C. Asir Rajan

    2010-01-01

    Full Text Available This paper presents a special gating pattern swapping technique for cascaded multilevel inverter, which is used for STATCOM.By using this technique besides minimizing the harmonic level, the inverter unit fundamental output voltages areequalized. Therefore, all the inverter units in each phase leg can equally share the exchanged active and reactive powerwith the utility grid. This greatly helps the dc-link voltages balancing control. PI Control is employed for improving performance.Fuzzy control is employed to the system for enhancing transient stability. The performance is analyzed usingdigital simulation.

  18. Embedded EZ-Source Inverters

    DEFF Research Database (Denmark)

    Chiang Loh, Poh; Gao, Feng; Blaabjerg, Frede

    2010-01-01

    Z-source inverters are recent topological options proposed for buck–boost energy conversion with a number of possible voltage- and current-type circuitries already reported in the literature. Comparing them, a common feature noted is their inclusion of an LC impedance network, placed between the dc...... input source and inverter bridge. This impedance network allows the output end of a voltage-type Z-source inverter to be shorted for voltage boosting without causing a large current flow and the terminal current of a current-type inverter to be interrupted for current boosting without introducing...... overvoltage oscillations to the system. Therefore, Z-source inverters are, in effect, safer and less complex and can be implemented using only passive elements with no additional active semiconductor needed. Believing in the prospects of Z-source inverters, this paper contributes by introducing a new family...

  19. Embedded EZ-Source Inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Gao, F.

    2008-01-01

    Z-source inverters are recent topological options proposed for buck-boost energy conversion with a number of possible voltage and current-type circuitries already reported in the literature. Comparing them, a common feature noted is their inclusion of a LC impedance network, placed between the dc...... input source and inverter bridge. This impedance network allows the output end of a voltage-type Z-source inverter to be shorted for voltage-boosting without causing a large current flow, and the terminal current of a current-type inverter to be interrupted for current boosting without introducing over......-voltage oscillations to the system. Therefore, Z-source inverters are in effect safer and less complex, and can be implemented using only passive elements with no additional active semiconductor needed. Believing in the prospects of Z-source inverters, this paper contributes by introducing a new family of embedded EZ-source...

  20. Sepsis-Induced Takotsubo Cardiomyopathy Leading to Torsades de Pointes

    Directory of Open Access Journals (Sweden)

    Nirav Patel

    2016-01-01

    Full Text Available Background. Takotsubo cardiomyopathy (TCM is sudden and reversible myocardial dysfunction often attributable to physical or emotional triggers. Case Report. We describe a 51-year-old man presented to emergency department with sepsis from urinary tract infection (UTI. He was placed on cefepime for UTI and non-ST-elevation myocardial infarction protocol given elevated troponins with chest pain. Subsequently, patient was pulseless with torsades de pointes (TdP and then converted to sinus rhythm with cardioversion. An echocardiogram revealed low ejection fraction with hypokinesis of the apical wall. Over 48 hours, the patient was extubated and stable on 3 L/min nasal cannula. He underwent a cardiac catheterization to evaluate coronary artery disease (CAD and was found to have mild nonobstructive CAD with no further findings. Conclusion. TCM is a rare disorder presenting with symptoms similar to acute coronary syndrome. Though traditionally elicited by physical and emotional triggers leading to transient left ventricular dysfunction, our case suggests that it may also be triggered by a urinary tract infection and lead to severe QT prolongation and a malignant ventricular arrhythmia in TdP.

  1. Takotsubo cardiomyopathy: an overlooked cause of chest pain

    Directory of Open Access Journals (Sweden)

    Leonardo Hackbart Bermudes

    2014-06-01

    Full Text Available Takotsubo cardiomyopathy (TTC, also known as apical ballooning syndrome, broken heart syndrome, or stress-induced cardiomyopathy, is defined as a transient disturbance of the left ventricle, which is quite often associated with electrocardiographic abnormalities that may mimic acute myocardial infarction. The syndrome is also characterized by a mild alteration of cardiac biomarkers in absence of coronary blood flow obstruction on the coronariography. Clinical presentation is often manifested by angina, dyspnea, syncope, and arrhythmias. Peculiarly, the left ventricle takes the form of “tako-tsubo” (a Japanese word for “octopus trap” on the imaging workup. The authors report the case of a post-menopausal, hypertensive, dyslipidemic and type-II diabetic woman admitted at the emergency service with acute chest pain post physical exertion. Electrocardiogram showed signs of ischemia and myocardial necrosis markers were mildly increased. Echocardiography and ventriculography showed apical and mid-ventricular akinesia, with mild atherosclerotic coronary lesions. Thus diagnostic workup and the outcome followed the diagnostic criteria for TTC. The authors called attention to the potential of overlooking this diagnosis, since this syndrome is still not widely recognized.

  2. Advances in PV Inverters

    DEFF Research Database (Denmark)

    Anthon, Alexander

    and preferably low complexity leads to new research demands. This is especially true in the field of low cost residential PV inverters where efficiencies are used as major selling arguments. Traditional converter topologies equipped with conventional Silicon based semiconductors to date reach their limitations......, a replacement of only two switching devices per phase leg can greatly reduce the semiconductor losses. The Hybrid-NPC converter can be seen as an attractive and cost competitive alternative to the Silicon Carbide based converter, also allowing to overcome the major drawbacks with the conventional Silicon IGBT...

  3. Gas cooled traction drive inverter

    Science.gov (United States)

    Chinthavali, Madhu Sudhan

    2013-10-08

    The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.

  4. Γ-Z-Source Inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Li, Ding; Blaabjerg, Frede

    2013-01-01

    Voltage-type Γ-Z-source inverters are proposed in this letter. They use a unique Γ-shaped impedance network for boosting their output voltage in addition to their usual voltage-buck behavior. Comparing them with other topologies, the proposed inverters use lesser components and a coupled transfor......Voltage-type Γ-Z-source inverters are proposed in this letter. They use a unique Γ-shaped impedance network for boosting their output voltage in addition to their usual voltage-buck behavior. Comparing them with other topologies, the proposed inverters use lesser components and a coupled...

  5. Is it possible to differentiate between Takotsubo cardiomyopathy and acute anterior ST-elevation myocardial infarction?

    NARCIS (Netherlands)

    Vervaat, Fabienne E.; Christensen, Thomas E.; Smeijers, Loes; Holmvang, Lene; Hasbak, Philip; Szabo, Balazs M.; Widdershoven, J.W. M. G.; Wagner, Galen S.; Bang, Lia E.; Gorgels, Anton P. M.

    2015-01-01

    Introduction Several studies have investigated the ability of the twelve-lead electrocardiogram (ECG) to reliably distinguish Takotsubo cardiomyopathy (TC) from an acute anterior ST-segment elevation myocardial infarction (STEMI). In these studies, only ECG changes were required – ST-segment

  6. Simplified High-Power Inverter

    Science.gov (United States)

    Edwards, D. B.; Rippel, W. E.

    1984-01-01

    Solid-state inverter simplified by use of single gate-turnoff device (GTO) to commutate multiple silicon controlled rectifiers (SCR's). By eliminating conventional commutation circuitry, GTO reduces cost, size and weight. GTO commutation applicable to inverters of greater than 1-kilowatt capacity. Applications include emergency power, load leveling, drives for traction and stationary polyphase motors, and photovoltaic-power conditioning.

  7. (SPWM) Voltage Source Inverter (VSI)

    African Journals Online (AJOL)

    The quest to achieve less-distorted dc-ac power conversion has resulted in the proliferation of many multilevel inverter configurations. This paper presents an experimental report of a simplified topology for single-phase, SPWM, three-level voltage source inverter wit R-L load. To keep the power circuit component count to a ...

  8. No myocardial vulnerability to mental stress in Takotsubo stress cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Olov Collste

    Full Text Available OBJECTIVES: Due to the frequent use of coronary angiography the awareness of Takotsubo stress cardiomyopathy (TSC has increased although the exact pathophysiology of TSC is still largely unknown. Our objective was to investigate the effects of mental stress on myocardial function, heart rate variability (HRV and salivary cortisol (SC in TSC patients. DESIGN: This study is a case-control study and a sub-study of the Stockholm Myocardial Infarction with Normal Coronaries (SMINC study. SETTING: Mental stress test was performed more than 6 months after the acute event in TSC patients and age- and sex-matched controls. Standard echocardiography and tissue Doppler imaging (TDI -derived time-phases of cardiac cycle were recorded to calculate myocardial performance index (MPI to assess ventricular function before and during mental stress. Holter-ECG recording was made to estimate HRV before, during and after mental stress. SC was measured at baseline, before and 20 minutes after mental stress. SUBJECTS: Twenty-two TSC patients and 22 sex-and age-matched controls were recruited from the SMINC-study and investigated with a mental stress test. All TSC patients had a previous normal cardiovascular magnetic resonance investigation. RESULTS: There were no significant differences at rest or during mental stress for left and right ventricular MPI or other standard diastolic variables between TSC patients and controls. HRV did not differ between TSC patients and controls. There was a trend towards less increase in SC after mental stress in TSC patients compared to controls. CONCLUSION: Mental stress did not induce a significant difference in myocardial function or HRV response between TSC and controls. Moreover, no significant difference could be seen in SC response at baseline, during or after mental stress. This study indicates that myocardial vulnerability to mental stress does not persist in TSC patients.

  9. Takotsubo Cardiomyopathy: One More Angiographic Evidence of Microvascular Dysfunction

    Directory of Open Access Journals (Sweden)

    Marco Loffi

    2018-01-01

    Full Text Available Background. Takotsubo cardiomyopathy (TC aetiology has not been completely understood yet. One proposed pathogenic mechanism was coronary microvascular dysfunction (MVD. This study compared coronary flow and myocardial perfusion in patients with TC, microvascular angina (MVA, and a control group (CG. Methods. Out of 42 consecutive patients presented to our centre with TC from 2013 to 2017; we retrospectively selected 27 patients. We compared them with a sex- and age-matched group of 27 MVA cases and 27 patients with normal coronary arteries (CG. The flow was evaluated in the three coronary arteries as TIMI flow and TIMI frame count (TFC. Myocardial perfusion was studied with Blush-Score and Quantitative Blush Evaluator (QuBE. Results. TFC, in TC, revealed flow impairment in the three arteries compared to the CG (left anterior descending artery (LAD: 22±8, 15±4; p=0.001 (right coronary artery: 12±4, 10±3; p=0,025 (left circumflex: 14±4, CG 11±3; p=0,006. QuBE showed myocardial perfusion impairment in the LAD territory in TC comparing with both the CG (8,9 (7,2–11,5 versus 11,4 (10–15,7; p=0,008 and the MVA group (8,9 (7,2–11,5 versus 13,5 (10–16; p=0,006. Conclusions. Our study confirmed that coronary flow is impaired in TC, reflecting a MVD. Myocardial perfusion defect was detected only in the LAD area.

  10. Analisis Harmonisa Inverter PWM Satu Fasa

    OpenAIRE

    Rejeki Simanjorang

    2008-01-01

    Pada tesis ini dianalisis harmonisa inverter PWM satu fasa. Inverter PWM satu fasa yang akan ditinjau adalah inverter satu fasa jembatan penuh (konvensional) dan inverter komposit. Analisis difokuskan pada penentuan pola penyaklaran yang optimum agar pembangkitan harmonisa dan switching losses inverter rendah. Untuk menentukan pola penyaklaran optimum maka dilakukan analisis yang berbasis pada rangkaian ekivalen harmonisa inverter satu fasa. Dengan menggunakan pola penyaklaran optimum, kedua ...

  11. Transformerless PV inverters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Borup, U.

    2009-12-15

    Since the start of the project the market for grid connected PV inverters have developed further. When the project started three - phase inverter were only available in high power systems. The technology developed within this project will enable three phase technology also to be implemented in string inverters for system down to 10 kW. We expect this to be very attractive due to the increased demand for symmetrical feed-in to the grid. The project relevance is therefore high and the sector continues to develop very much driven by technology. Especially the inverter technology is getting a lot of focus. The inverter systems are expected to take a much larger role in supporting the electrical grid in the future. The technology platform developed within the project is prepared to be extended with these utility functionalities. The main results of the project were: 1) A new technology concept for transformer-less inverters has been demonstrated with a number of prototypes. 2) Efficiency above 97,7% has been proven. 3) Efficiency and Maximum power point tracking has been optimized to ensure that almost all energy produced of the panels is transferred to the grid. 4) The platform is developed with a very fast control board, which enables extended functionality as demanding grid supporting functions in the future. Details about cost price and details about the control loop implementation is excluded from the report due to the competitive situation for Danfoss Solar Inverters A/S. (LN)

  12. Takotsubo cardiomyopathy: real life management in the intensive coronary care unit.

    Science.gov (United States)

    Pullara, A; Chinaglia, A; Giammaria, M; Bequaraj, F; Orlando, F; Coda, L; Lucciola, M T; Forno, D; Ravera, L; Cecchi, E; Gaita, F; Belli, R

    2013-10-01

    Takotsubo cardiomyopathy is a cardiac syndrome characterized by reversible left ventricular dysfunction, ischemic changes on electrocardiogram, elevation of cardiac biomarkers, absence of obstructive coronary artery disease in the setting of various stressing conditions. To date, little is known on best clinical management of this syndrome in coronary care units. Whe thus aimed to present our experience in a real life takotsubo population. We identified all patients with Takotsubo cardiomyopathy at our center Maria Vittoria Hospital, Turin, between October 2006 and February 2012. Patients where considered to have Takotsubo syndrome if they presented chest pain on admission, new elettrocardiographic changes suggestive of myocardial ischemia, evidence of apical balloning with hyperkinesis of basal segments on echocardiography, rise in troponin I and, after coronary angiography, no coronary artery disease. We adjudicated the following clinical events: death and recurrence of ischemic events; we also made a detailed analysis of the stressing conditions leading to clinical syndrome. A total of 26 patients were included, 4 (15%) males and 22 (85%) females; mean age was 71±13. After more than 1 year median follow-up the incidence of death was 7.7% (2 deaths), with all deaths, due to cardiogenic shock, occurring in the first 10 days of hospitalization; 2 patients (8%) experienced recurrence of ischemic event. Leading cause of Takostubo was major depressive episode (16%), followed by mourning (12%), falling down with difficulties in standing up (12%), vomiting (8%) and pulmonary infection (8%). In the coronary care unit major complications of patients with Takotsubo syndrome were acute hearth failure (62%), cardiogenic shock (27%), sepsis (31%), pulmonary aedema (27%) and anemia (12%). Two patients needed non-invasive ventilation support and one intra-aortic balloon conterpulasation. In addition one patient developed rabdomyolysis and one left heart thrombus. Cornerstone

  13. Low prevalence of diabetes mellitus in patients with Takotsubo syndrome: A plausible 'protective' effect with pathophysiologic connotations.

    Science.gov (United States)

    Madias, John E

    2016-04-01

    The pathophysiology of Takotsubo syndrome is still elusive; coronary vasospasm, microvascular dysfunction, or catecholamine-mediated injury to the cardiomyocytes, effected by local release from the autonomic nerves and/or blood-borne catecholamines, are considered as tentative cause(s). Diabetes mellitus-induced autonomic neuropathy leads to a brain-heart disconnection, and it can conceivably ameliorate/block the effect of an unbridled adrenergic storm to the heart, and the emergence of Takotsubo syndrome. This study sought to evaluate the prevalence of diabetes mellitus in patients with Takotsubo syndrome. All the papers accessed in PubMed were reviewed, to evaluate the prevalence of diabetes mellitus and hypertension in Takotsubo syndrome patients, employing the rate of the latter as an index of how representative of the general population were the study patients, and the rate of the former as the focus of this investigation. Out of the 1932 papers, 959 were suitable for analysis, reporting on 33,894 patients (88.9% women) with Takotsubo syndrome. In five subanalyses, of all patients, patients reported individually, patients reported collectively in case series, patients ⩾ 60 years old reported individually, and patients ⩾ 65 years old reported individually, the prevalence of hypertension was 57.4%, 42.8%, 57.9%, 50.4%, and 52.2%, correspondingly, and comparable to the 65.4% shown by the National Health and Nutrition Examination Survey (NHANES). The prevalence of diabetes mellitus in the five subgroups was 16.8%, 10.2%, 17.0%, 11.9%, and 12.5%, correspondingly, and lower than the 26.9% found by the NHANES. The prevalence of diabetes mellitus in patients with Takotsubo syndrome is low. This insight may be useful for the diagnosis, pathophysiology unraveling, and employment of autonomic adrenergic blocking agents in the management of patients with Takotsubo syndrome. © The European Society of Cardiology 2015.

  14. Nanowire NMOS Logic Inverter Characterization.

    Science.gov (United States)

    Hashim, Yasir

    2016-06-01

    This study is the first to demonstrate characteristics optimization of nanowire N-Channel Metal Oxide Semiconductor (NW-MOS) logic inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. A computer-based model used to produce static characteristics of NW-NMOS logic inverter. In this research two circuit configuration of NW-NMOS inverter was studied, in first NW-NMOS circuit, the noise margin for (low input-high output) condition was very low. For second NMOS circuit gives excellent noise margins, and results indicate that optimization depends on applied voltage to the inverter. Increasing gate to source voltage with (2/1) nanowires ratio results better noise margins. Increasing of applied DC load transistor voltage tends to increasing in decreasing noise margins; decreasing this voltage will improve noise margins significantly.

  15. Inverter Ground Fault Overvoltage Testing

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Andy [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Nelson, Austin [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chebahtah, Justin [SolarCity Corporation, San Mateo, CA (United States); Wang, Trudie [SolarCity Corporation, San Mateo, CA (United States); McCarty, Michael [SolarCity Corporation, San Mateo, CA (United States)

    2015-08-12

    This report describes testing conducted at NREL to determine the duration and magnitude of transient overvoltages created by several commercial PV inverters during ground fault conditions. For this work, a test plan developed by the Forum on Inverter Grid Integration Issues (FIGII) has been implemented in a custom test setup at NREL. Load rejection overvoltage test results were reported previously in a separate technical report.

  16. Pediatric Extracorporeal Cardiopulmonary Resuscitation Patient With Traumatic Subarachnoid Hemorrhage and Takotsubo Syndrome.

    Science.gov (United States)

    Pearson, Thomas E; Frizzola, Meg A; Priest, Marc A; Rochman, Monica F; Froehlich, Curtis D

    Takotsubo syndrome is rare in pediatric patients but must be considered in patients with subarachnoid hemorrhage with pulmonary edema and cardiomyopathy. A systematic, collaborative approach is needed to facilitate emergent transfer of patients where extracorporeal cardiopulmonary resuscitation (e-CPR) is used as a lifesaving measure. Extracorporeal membrane oxygenation (ECMO) use in transport requires preplanning, role delineation, resources, and research efforts to be successful. We present an unusual transport case of successful e-CPR/ECMO treatment of Takotsubo syndrome in a 12-year-old boy with an isolated traumatic intracranial injury, cardiomyopathy with pulmonary edema, and multiple cardiac arrests. Copyright © 2018 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  17. Takotsubo Cardiomyopathy Triggered by Venous Air Embolism During Craniotomy in the Sitting Position.

    Science.gov (United States)

    Raimann, Florian; Senft, Christian; Honold, Jörg; Zacharowski, Kai; Seifert, Volker; Mersmann, Jan

    2017-11-01

    We present a case of stress-induced cardiomyopathy (Takotsubo cardiomyopathy) caused by a venous air embolism during a craniotomy performed in the sitting position. A 69-year-old woman was admitted to the neurosurgical department and scheduled for elective resection of a cerebellar metastasis in the sitting position. After craniotomy and opening of the posterior fossa, a venous air embolism was detected via transesophageal echocardiography. The patient immediately presented with cardiac decompensation with signs of takotsubo or stress-induced cardiomyopathy. Intensivists and anesthesiologists in the operating room and in intensive care units need to be aware of stress-induced cardiomyopathy as a probably underdiagnosed disease entity, especially as management differs significantly from other forms of cardiogenic shock. Diagnosis can be accomplished quickly by bedside echocardiography, emphasizing the need for availability of this tool and the integration of stress-induced cardiomyopathy in diagnostic algorithms in the intensive care unit. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Invertibility in L-Topological Spaces

    Directory of Open Access Journals (Sweden)

    Anjaly Jose

    2014-03-01

    Full Text Available In this paper, we extend the concept of invertibility to L-topological spaces and delineate its properties. Then, we study further completely invertible L-topological spaces and introduce two types of invertible L-topologies based on the inverting maps, studying their sums, subspaces and simple extensions.

  19. Acute pulmonary edema caused by takotsubo cardiomyopathy in a pregnant woman undergoing transvaginal cervical cerclage

    OpenAIRE

    Lee, Jae-Young; Kwon, Hyun-Jung; Park, Sang-Wook; Lee, Yu-Mi

    2017-01-01

    Abstract Background: The physiological changes associated with pregnancy may predispose pregnant women to pulmonary edema. Other known causes of pulmonary edema during pregnancy include tocolytic drugs, preeclampsia, eclampsia, and peripartum cardiomyopathy. Methods: We describe a rare case of pulmonary edema caused by takotsubo cardiomyopathy in a pregnant woman at 14 weeks of gestation who was undergoing emergency transvaginal cervical cerclage. Results: Intraoperative chest radiography rev...

  20. The link between spontaneous coronary artery dissection and takotsubo cardiomyopathy: analysis of the published cases.

    Science.gov (United States)

    Buccheri, Dario; Zambelli, Giulia

    2017-12-01

    Spontaneous coronary artery dissection (SCAD) and takotsubo cardiomyopathy (TTS) are two non-atherosclerotic causes of myocardial infarction. They share several common features. Firstly, they have a predilection for the female gender and, in both, the exact mechanism has yet to be fully established. Both they could be responsible for an acute coronary syndrome. Hence, we want to do further consideration based on pathophysiology, literature review, and cases presented affected by both entities up today.

  1. Management of airway obstruction with nebulised adrenaline resulting in takotsubo cardiomyopathy: case report.

    Science.gov (United States)

    Keshtkar, F; Dale, O T; Bennett, W O; Hall, C E

    2016-09-01

    Takotsubo cardiomyopathy has been associated with the use of catecholamines; however, its development after the use of nebulised adrenaline for the management of acute airway obstruction has not previously been described. A 66-year-old man with squamous cell carcinoma of the larynx, with tumour-node-metastasis staging of T3N2cM0, confirmed by biopsy and computed tomography, presented to the emergency department with acute airway obstruction. He was treated twice with nebulised adrenaline and intravenous dexamethasone. After a period of 24 hours, cardiac rhythm changes were noted on telemetry. A 12-lead electrocardiogram showed widespread T-wave inversion and QT prolongation suggestive of an acute coronary syndrome. Coronary angiography demonstrated no coronary artery disease, but left ventricular angiography showed marked apical ballooning and apical wall akinesia consistent with a diagnosis of takotsubo cardiomyopathy. Takotsubo cardiomyopathy can mimic true ischaemic heart disease and the diagnosis requires a high index of suspicion in patients managed with nebulised adrenaline.

  2. Aborted Sudden Cardiac Death in a Female Patient Presenting with Takotsubo-Like Cardiomyopathy due to Epicardial Coronary Vasospasm

    Directory of Open Access Journals (Sweden)

    Sorin Giusca

    2017-01-01

    Full Text Available Takotsubo cardiomyopathy is characterized by apical ballooning of the left ventricle (LV in the absence of relevant coronary artery stenosis, which typically occurs in elderly women after emotional stress. Catecholamine cardiotoxicity, metabolic disturbance, and coronary microvascular impairment have previously been proposed as underlying pathophysiologic mechanisms of takotsubo cardiomyopathy, whereas myocardial stunning resulting from epicardial coronary artery vasospasm is not generally accepted as a cause of takotsubo cardiomyopathy. The prognosis of takotsubo cardiomyopathy is generally more favourable compared to myocardial infarction; however, severe complications such as rupture of the LV and life-threatening arrhythmias may occur. Herein, we describe a case of an 84-year-old female, who presented with aborted sudden cardiac death due to ventricular fibrillation. Echocardiography suggested LV apical ballooning with severely impaired LV-function, so that takotsubo cardiomyopathy was suspected. However, coronary angiography revealed epicardial spasm of the left anterior ascending, which resolved after intracoronary injection of 0.2 mg nitroglycerine. Cardiac magnetic resonance exhibited subendocardial late enhancement and echocardiography showed normalization of LV dysfunction during follow-up. The patient was put on conservative treatment with nitrates and calcium inhibitors and ICD implantation were deferred.

  3. Acute pulmonary edema caused by takotsubo cardiomyopathy in a pregnant woman undergoing transvaginal cervical cerclage: A case report.

    Science.gov (United States)

    Lee, Jae-Young; Kwon, Hyun-Jung; Park, Sang-Wook; Lee, Yu-Mi

    2017-01-01

    The physiological changes associated with pregnancy may predispose pregnant women to pulmonary edema. Other known causes of pulmonary edema during pregnancy include tocolytic drugs, preeclampsia, eclampsia, and peripartum cardiomyopathy. We describe a rare case of pulmonary edema caused by takotsubo cardiomyopathy in a pregnant woman at 14 weeks of gestation who was undergoing emergency transvaginal cervical cerclage. Intraoperative chest radiography revealed severe pulmonary edema and echocardiography indicated moderate left ventricular dysfunction with akinesia of the mid to apical left ventricular wall segment, which is reflective of takotsubo cardiomyopathy. With early detection and appropriate management, the patient was stabilized in a relatively short period of time. Based on her clinical signs and symptoms, we suspect that the pulmonary edema was caused by takotsubo cardiomyopathy.

  4. Accelerating development of advanced inverters :

    Energy Technology Data Exchange (ETDEWEB)

    Neely, Jason C.; Gonzalez, Sigifredo; Ropp, Michael; Schutz, Dustin

    2013-11-01

    The high penetration of utility interconnected photovoltaic (PV) systems is causing heightened concern over the effect that variable renewable generation will have on the electrical power system (EPS). These concerns have initiated the need to amend the utility interconnection standard to allow advanced inverter control functionalities that provide: (1) reactive power control for voltage support, (2) real power control for frequency support and (3) better tolerance of grid disturbances. These capabilities are aimed at minimizing the negative impact distributed PV systems may have on EPS voltage and frequency. Unfortunately, these advanced control functions may interfere with island detection schemes, and further development of advanced inverter functions requires a study of the effect of advanced functions on the efficacy of antiislanding schemes employed in industry. This report summarizes the analytical, simulation and experimental work to study interactions between advanced inverter functions and anti-islanding schemes being employed in distributed PV systems.

  5. Addressable Inverter Matrix Tests Integrated-Circuit Wafer

    Science.gov (United States)

    Buehler, Martin G.

    1988-01-01

    Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.

  6. Inverter design for high frequency power distribution

    Science.gov (United States)

    King, R. J.

    1985-01-01

    A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.

  7. CT and MR findings of the inverted papilloma

    International Nuclear Information System (INIS)

    Lim, Seong Youb; Kim, Hak Jin; Lee, Jun Woo; Park, Jae Yeong; Lee, Sung Gap; Kim, Byung Soo; Roh, Hwan Jung; Baik, Seung Kook

    1997-01-01

    The purpose of this study is to describe the CT and MR findings of inverted papilloma and to determine the specific differential finding between inverted papilloma with and without coexisting malignancy. Twenty-two histopathologically proven inverted papillomas were included in this study ; in six patients there was coexisting malignancy. Twenty-two CT images and eight MR images were retrospectively reviewed. On CT images, the inverted papillomas were seen as unilateral sinonasal masses with bone remodeling (n=15) rather than bone destruction (n=1) and showed iso- or slightly high attenuation. Three of the six malignant cases showed aggressive bone destruction and widespread extension into the orbit, intracranial and buccal spaces, and pterygopalatine fossa. On MR images, the inverted papillomas (n=3) were iso- (n=2) or slightly high (n=1) in signal intensity in relation to muscle on T1-weighted images, and high (n=3) on T2-weighted images. Gadolinium enhanced images showed heterogenous moderate enhancement. In the cases of coexisting malignancy (n=5), the masses were iso- (n=5) on T1-weighted images, high (n=5) on T2-weighted images and also showed heterogenous moderate enhancement. Inverted papilloma should be considered in the differential diagnosis of a bulky unilateral nasal mass extending into the adjacent paranasal sinuses, especially in an elderly patient with chronic nasal obstruction. Although there were no specific differential findings in signal intensity and enhancement pattern on CT and MR images between benign and malignant inverted papilloma, aggressive bone destruction and widespread extension beyond the sinonasal cavity are findings which are highly suggestive of coexisting malignancy

  8. Advanced Modular Inverter Technology Development

    Energy Technology Data Exchange (ETDEWEB)

    Adam Szczepanek

    2006-02-04

    Electric and hybrid-electric vehicle systems require an inverter to convert the direct current (DC) output of the energy generation/storage system (engine, fuel cells, or batteries) to the alternating current (AC) that vehicle propulsion motors use. Vehicle support systems, such as lights and air conditioning, also use the inverter AC output. Distributed energy systems require an inverter to provide the high quality AC output that energy system customers demand. Today's inverters are expensive due to the cost of the power electronics components, and system designers must also tailor the inverter for individual applications. Thus, the benefits of mass production are not available, resulting in high initial procurement costs as well as high inverter maintenance and repair costs. Electricore, Inc. (www.electricore.org) a public good 501 (c) (3) not-for-profit advanced technology development consortium assembled a highly qualified team consisting of AeroVironment Inc. (www.aerovironment.com) and Delphi Automotive Systems LLC (Delphi), (www.delphi.com), as equal tiered technical leads, to develop an advanced, modular construction, inverter packaging technology that will offer a 30% cost reduction over conventional designs adding to the development of energy conversion technologies for crosscutting applications in the building, industry, transportation, and utility sectors. The proposed inverter allows for a reduction of weight and size of power electronics in the above-mentioned sectors and is scalable over the range of 15 to 500kW. The main objective of this program was to optimize existing AeroVironment inverter technology to improve power density, reliability and producibility as well as develop new topology to reduce line filter size. The newly developed inverter design will be used in automotive and distribution generation applications. In the first part of this program the high-density power stages were redesigned, optimized and fabricated. One of the main

  9. Invertible extensions and growth conditions

    Czech Academy of Sciences Publication Activity Database

    Badea, C.; Müller, Vladimír

    2004-01-01

    Roč. 339, - (2004), s. 21-26 ISSN 1631-073X R&D Projects: GA ČR GA201/03/0041; GA AV ČR KSK1019101 Institutional research plan: CEZ:AV0Z1019905 Keywords : invertible extensions * growth conditions Subject RIV: BA - General Mathematics Impact factor: 0.284, year: 2004

  10. Inverting an Introductory Statistics Classroom

    Science.gov (United States)

    Kraut, Gertrud L.

    2015-01-01

    The inverted classroom allows more in-class time for inquiry-based learning and for working through more advanced problem-solving activities than does the traditional lecture class. The skills acquired in this learning environment offer benefits far beyond the statistics classroom. This paper discusses four ways that can make the inverted…

  11. Overload protection system for power inverter

    Science.gov (United States)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  12. Inverter for Installations with Intermittent Electricity Production

    OpenAIRE

    Ermuraki Iu.; Berzan V.

    2016-01-01

    A new architecture of the inverter used in the convertion of electric energy generated by renewable energy sources is studied in this paper. The distinctive features of this inverter is the special block which compensates pulsing of the current with double frequency, characteristic for these inverters. The switching of electronic keys is realized using the method TCM In this block, like in the inverter, which assures the switching at the voltages near to zero (ZVC). The proposed algorithm of ...

  13. Improved Performance via the Inverted Classroom

    Science.gov (United States)

    Weinstein, Randy D.

    2015-01-01

    This study examined student performance in an inverted thermodynamics course (lectures provided by video outside of class) compared to a traditional lecture class. Students in the inverted class performed better on their exams. Students in the bottom third of the inverted course showed the greatest improvement. These bottom third students had a C…

  14. 21 CFR 184.1859 - Invert sugar.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Invert sugar. 184.1859 Section 184.1859 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Substances Affirmed as GRAS § 184.1859 Invert sugar. (a) Invert sugar (CAS Reg. No. 8013-17-0) is an aqueous...

  15. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...

  16. Multilevel Inverter by Cascading Industrial VSI

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Pedersen, John Kim

    2002-01-01

    -source inverter that uses three IGBT triphase inverter modules along with an output transformer to obtain a 3 p.u. multilevel output voltage is introduced. The system yields in high-quality multistep voltage with up to 4 levels and low dv/dt, balanced operation of the inverter modules, each supplying a third...

  17. Cardiomiopatia de Takotsubo: uma causa rara de choque cardiogênico simulando infarto agudo do miocárdio Takotsubo cardiomiopathy: a rare cause of cardiogenic shock simulating acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Jayro Thadeu Paiva de Vasconcelos

    2005-08-01

    Full Text Available Cardiomiopatia de Takotsubo é uma causa rara de aneurisma ventricular esquerdo agudo, na ausência de coronariopatia, só recentemente descrita na literatura mundial. Os sintomas podem assemelhar-se aos do infarto agudo do miocárdio com dor torácica típica. A imagem do balonamento ventricular sugestivo de haltere ou "Takotsubo" (dispositivo utilizado no Japão para prender Octopus é característico desta nova síndrome e usualmente há desaparecimento do movimento discinético até o 18º dia do início dos sintomas, em média.Takotsubo Cardiomiopathy is a rare cause of acute left ventricular aneurysm, in the absence of coronariopathy, only recently described in world literature. Symptoms may be similar to those from acute myocardial infarction with typical thoracic pain. The image of dumbbell or Takotsubo (a device used in Japan to capture octopus suggestive ventricular ballooning is characteristic of that new syndrome and there is usually the disappearing of dyskinetic movement up to the 18th day from the beginning of the symptoms, in average.

  18. Happy heart syndrome: role of positive emotional stress in takotsubo syndrome

    Science.gov (United States)

    Ghadri, Jelena R.; Sarcon, Annahita; Diekmann, Johanna; Bataiosu, Dana Roxana; Cammann, Victoria L.; Jurisic, Stjepan; Napp, Lars Christian; Jaguszewski, Milosz; Scherff, Frank; Brugger, Peter; Jäncke, Lutz; Seifert, Burkhardt; Bax, Jeroen J.; Ruschitzka, Frank; Lüscher, Thomas F.; Templin, Christian; Schwyzer, Moritz; Franke, Jennifer; Katus, Hugo A.; Burgdorf, Christof; Schunkert, Heribert; Thiele, Holger; Bauersachs, Johann; Tschöpe, Carsten; Rajan, Lawrence; Michels, Guido; Pfister, Roman; Ukena, Christian; Böhm, Michael; Erbel, Raimund; Cuneo, Alessandro; Kuck, Karl-Heinz; Jacobshagen, Claudius; Hasenfuß, Gerd; Karakas, Mahir; Koenig, Wolfgang; Rottbauer, Wolfgang; Said, Samir M.; Braun-Dullaeus, Ruediger C.; Cuculi, Florim; Banning, Adrian; Fischer, Thomas A.; Vasankari, Tuija; Airaksinen, K.E. Juhani; Fijalkowski, Marcin; Rynkiewicz, Andrzej; Opolski, Grzegorz; Dworakowski, Rafal; MacCarthy, Philip; Kaiser, Christoph; Osswald, Stefan; Galiuto, Leonarda; Crea, Filippo; Dichtl, Wolfgang; Franz, Wolfgang M.; Empen, Klaus; Felix, Stephan B.; Delmas, Clément; Lairez, Olivier; Erne, Paul; Prasad, Abhiram

    2016-01-01

    Abstract Aims Takotsubo syndrome (TTS) is typically provoked by negative stressors such as grief, anger, or fear leading to the popular term ‘broken heart syndrome’. However, the role of positive emotions triggering TTS remains unclear. The aim of the present study was to analyse the prevalence and characteristics of patients with TTS following pleasant events, which are distinct from the stressful or undesirable episodes commonly triggering TTS. Methods and results Takotsubo syndrome patients with preceding pleasant events were compared to those with negative emotional triggers from the International Takotsubo Registry. Of 1750 TTS patients, we identified a total of 485 with a definite emotional trigger. Of these, 4.1% (n = 20) presented with pleasant preceding events and 95.9% (n = 465) with unequivocal negative emotional events associated with TTS. Interestingly, clinical presentation of patients with ‘happy heart syndrome’ was similar to those with the ‘broken heart syndrome’ including symptoms such as chest pain [89.5% (17/19) vs. 90.2% (412/457), P = 1.0]. Similarly, electrocardiographic parameters, laboratory findings, and 1-year outcome did not differ. However, in a post hoc analysis, a disproportionate higher prevalence of midventricular involvement was noted in ‘happy hearts’ compared with ‘broken hearts’ (35.0 vs. 16.3%, P = 0.030). Conclusion Our data illustrate that TTS can be triggered by not only negative but also positive life events. While patient characteristics were similar between groups, the midventricular TTS type was more prevalent among the ‘happy hearts’ than among the ‘broken hearts’. Presumably, despite their distinct nature, happy and sad life events may share similar final common emotional pathways, which can ultimately trigger TTS. PMID:26935270

  19. Tako-tsubo Syndrome in Men: Rare, but With Poor Prognosis.

    Science.gov (United States)

    Pérez-Castellanos, Alberto; Martínez-Sellés, Manuel; Mejía-Rentería, Hernán; Andrés, Mireia; Sionis, Alessandro; Almendro-Delia, Manuel; Martín-García, Ana; Aguilera, María Cruz; Pereyra, Eduardo; Linares Vicente, José A; García de la Villa, Bernardo; Núñez-Gil, Iván J

    2017-11-06

    Tako-tsubo syndrome is a potentially serious disease during the acute phase. It mimics myocardial infarction, but with no potentially causative coronary lesions. The aim of this study was to analyze the clinical course and outcome of patients with tako-tsubo syndrome by sex. We analyzed the characteristics of patients included in the RETAKO registry from 2003 to 2015, a multicenter registry with participation of 32 Spanish hospitals. Of 562 patients included, 493 (87.7%) were women. Chest pain was less frequent as an initial symptom in men than in women (43 [66.2%] vs 390 [82.8%]; P < .01). The prognosis was worse in men, with higher in-hospital mortality (3 [4.4%] vs 1 [0.2%]; P < .01), longer intensive care stay (4.2 ± 3.7 vs 3.2 ± 3.2 days; P = .03) and a higher frequency of severe heart failure (22 [33.3%] vs 95 [20.3%]; P = .02). However, dynamic obstruction at the left-ventricular outflow tract occurred exclusively in women (39 [7.9%] vs 0 [0.0%]; P = .02). The incidence of functional mitral regurgitation was also higher in women (52 [10.6%] vs 2 [2.9%]; P = .04). Tako-tsubo syndrome shows wide differences by sex in terms of its incidence, presentation, and outcomes. Prognosis is worse in men. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  20. 5-Fluorouracil-induced acute reversible heart failure not explained by coronary spasms, myocarditis or takotsubo

    DEFF Research Database (Denmark)

    Fakhri, Yama; Dalsgaard, Morten; Nielsen, Dorte

    2016-01-01

    A 69-year-old woman presented with arterial hypotension, pulmonary oedema and a severely depressed left ventricular ejection fraction (LVEF) of 25% only 3 days after having received her first treatment for colorectal cancer with 5-fluorouracil (5-FU)-based therapy. The ECG demonstrated widespread......, cardiac MRI scan 9 days later showed a normal LVEF with signs of neither myocardial oedema nor necrosis. Despite the high therapeutic efficacy of 5-FU in treatment of colorectal cancer, it is associated with undesired cardiac toxicities including coronary spasms, toxic inflammation and takotsubo...

  1. Supra-Hisian Conduction Block as an Unusual Presenting Feature of Takotsubo Cardiomyopathy.

    Science.gov (United States)

    Prabhu, Mukund Aravind; Pai, Praveen Gopalakrishna; Vupputuri, Anjith; Shekhar, Saritha; Harikrishnan, Madhavankutty Santhakumari; Kumaraswamy, Natarajan Umayammal

    2017-05-01

    Atrioventricular (AV) block is rare in Takotsubo cardiomyopathy (TC). A 66-year-old female presented with fatigue. Her electrocardiogram revealed 3:2 Mobitz Type II AV block, confirmed to be supra-Hisian by electrophysiological study. Echocardiogram and left ventricular angiogram showed moderate left ventricular dysfunction and apical ballooning, whereas coronary angiogram revealed mildly ectatic coronaries. At 2 weeks AV block persisted, needing permanent pacemaker implantation. At 1-month follow-up, she had normal ventricular function and no AV block. Delayed recovery of AV conduction is possible in TC, thus implying to wait for a longer period before implanting a pacemaker. © 2016 Wiley Periodicals, Inc.

  2. Evidence for an association between tako-tsubo cardiomyopathy and bronchial asthma: retrospective analysis in a primary care hospital.

    Science.gov (United States)

    von Blotzheim, Leonardo Glutz; Christen, Stefan; Wieser, Stephan; Ulrich, Silvia; Huber, Lars C

    2015-01-01

    We investigated the prevalence of bronchial asthma in patients with Tako-Tsubo Syndrome (TTS). This retrospective case-series study was conducted in a primary care hospital in Zurich, Switzerland. Data of all patients with newly diagnosed TTS (2002 - 2012) were assessed electronically by the use of ICD-10. Asthma prevalence was compared to published epidemiologic data. Bronchial asthma is characterized by airway inflammation and, during attack, release of endogenous catecholamines. Sympathomimetic drugs are the mainstay of treatment for asthma patients. Likewise, catecholamine mediated diffuse microvascular myocardial dysfunction seems to be of critical importance for the development of TTS. 20 cases of TTS were identified. 90% were female, showed a median age of 70±13y [25y - 90y], an apical and/or midventricular ballooning pattern with preserved basal function and a median initial LVEF of 34±9% [25% - 55%]. 65% of patients underwent coronary angiography to rule out significant coronary artery disease. Hypertension was present in 45% of patients, 35% were smokers, none was suffering from diabetes. Prevalence of asthma in patients with TTS was significantly higher compared to the normal population (25% vs. 7%, p=0.012). In 30% of the TTS patients an iatrogenic cause for development of TTS was identified. Prevalence of asthma was significantly higher in patients with TTS compared to epidemiologic data from an age-matched population. Phenotypes of patients developing obstructive ventilatory disease and TTS might share common pathogenic mechanisms beyond the use of bronchodilatators. In addition, we identified other iatrogenic etiologies in patients with TTS.

  3. Takotsubo cardiomyopathy in an 81-year-old woman after injection of bone cement during hemiarthroplasty: An orthogeriatric case report

    Directory of Open Access Journals (Sweden)

    Paolo Mazzola

    2016-01-01

    Conclusion: Despite the good prognosis associated with early recognition, Takotsubo represents a life-threatening adverse event. Considering its possible pathogenesis, a “gentle care” approach and the optimization of pain control must be pursued in elderly subjects with hip fracture, aiming at reducing the stress of the hospitalization and related procedures.

  4. Basal wall hypercontraction of Takotsubo cardiomyopathy in a patient who had been diagnosed with dilated cardiomyopathy: a case report.

    Science.gov (United States)

    Ichihara, Noboru; Fujita, Shuichi; Kanzaki, Yumiko; Fujisaka, Tomohiro; Ozeki, Michishige; Ishizaka, Nobukazu

    2017-12-12

    Takotsubo cardiomyopathy is characterized by the basal hypercontractility and apical ballooning of the left ventriculum and T-wave inversion in the electrocardiogram. It has been suggested that Takotsubo cardiomyopathy might underlie the pathogenesis of persistent cardiac dysfunction; however, few reports are present demonstrating the advent of Takotsubo cardiomyopathy in patients with idiopathic cardiomyopathy. A 64-year-old women was admitted due to dyspnea on effort and lower extremity edema. She had been diagnosed with idiopathic dilated cardiomyopathy 2.5 years before owing to the reduced left ventricular ejection fraction (24%), normal coronary artery, and interstitial fibrosis of the myocardial samples. On admission, her electrocardiogram showed giant negative T wave in II, III, aVF, and precordial leads. Echocardiography showed dyskinesis of the left ventricular apex and hypercontraction of the basal wall, which had not been observed in the previous examinations. Coronary angiography showed normal coronary arteries, and apical ballooning and basal hypercontractility was confirmed by left ventriculography. On day 15 of admission, contraction of apical wall was recovered, and basal hypercontraction was disappeared. The present case is the first report demonstrating appearance the transient basal wall hypercontraction along with the advent of Takotsubo cardiomyopathy in a patient diagnosed with dilated cardiomyopathy. Whether such findings are indicative of fair prognosis and have the utility of understanding the pathogenesis of dilated cardiomyopathy needs further investigation.

  5. Tako-tsubo cardiomyopathy: how to understand possible pathophysiological mechanism and the role of (123)I-MIBG imaging

    NARCIS (Netherlands)

    Verschure, Derk O.; Somsen, G. Aernout; van Eck-Smit, Berthe L. F.; Knol, Remco J. J.; Booij, Jan; Verberne, Hein J.

    2014-01-01

    Tako-tsubo cardiomyopathy (TCM) is an increasingly recognized clinical syndrome characterized by acute reversible apical ventricular dysfunction, commonly preceded by exposure to severe physical or emotional stress. In this review, we give a short overview on clinical presentation and treatment of

  6. Fault-tolerant three-level inverter

    Science.gov (United States)

    Edwards, John; Xu, Longya; Bhargava, Brij B.

    2006-12-05

    A method for driving a neutral point clamped three-level inverter is provided. In one exemplary embodiment, DC current is received at a neutral point-clamped three-level inverter. The inverter has a plurality of nodes including first, second and third output nodes. The inverter also has a plurality of switches. Faults are checked for in the inverter and predetermined switches are automatically activated responsive to a detected fault such that three-phase electrical power is provided at the output nodes.

  7. Neutral Point Clamped Npc Type Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Purohit Sadanand Chandrashekhar

    2015-08-01

    Full Text Available Concept of the multilevel inverter is same as the other inverter which is to converts Direct current DC to Alternating current AC .The inverted current can be at any vital voltage and frequency with the use of pertinent transformers switching and control circuits. From the source like batteries solar panel wind turbine or fuel cell the inverter will convert the DC electricity to AC electricity. In this modern technology Power electronics is very important where it used in a great variety of product. With the high potential in high power for industry multilevel inverter will become most popular for so many applications.

  8. The role of echocardiography in diagnosis and follow up of patients with takotsubo cardiomyopathy or acute ballooning syndrome.

    Science.gov (United States)

    Naser, Nabil; Buksa, Marko; Kusljugic, Zumreta; Terzic, Ibrahim; Sokolovic, Sekib; Hodzic, Enisa

    2011-01-01

    The transient left ventricular apical ballooning syndrome, also known as takotsubo cardiomyopathy was first described in Japan approximately 20 years ago (Satoh and coworkers, 1991). It was later described elsewhere as well and is being increasingly recognized. Takotsubo Cardiomyopathy characterized by transient apical and midventricular LV dysfunction in the absence of significant coronary artery disease that is triggered by emotional or physical stress. Its name refers to a contraption used for catching octopuses and suggests the aspect assumed by the ventricle during the systole due to the typical regional wall motion abnormalities that occur after onset. Takotsubo cardiomiopathy occurring mainly in post-menopausal women, echocardiography in the Takotsubo cardiomyopathy reveals during its acute phase a ballooning resembling the octopus trap configuration--the apex and lateral ventricular segments are hypokinetic while the base is hyperkinetic--along with reduced ejection fraction. Ventricular function will usually recover within a few days/weeks. The objective of this study is to determine the role of echocardiography in detecting and establishing the diagnosis of Takotsubo cardiomiopathy in patients with suspect acute coronary syndrome and during the follow up period. The study covered 12 adult patients the majority are women (92%) who were subjected to echocardiography evaluation as part of the clinical cardiological examination due to suspect acute coronary syndrome or Takotsubo Stress Cardiomyopathy. The patients were examined on an ultrasound machine Philips iE 33 x Matrix, ATL HDI and GE Vived 7 equipped with all cardiologic probes for adults and multi-plan TEE probes. We evaluated clinical characteristics, LV systolic function, biomarkers, and prognosis in all patients. Among all the patients referred for Echocardiographic evaluation for left ventricle motion abnormalities with suspect acute coronary syndrome, the echo exam revealed 12 patients with acute

  9. Integrated Inverter And Battery Charger

    Science.gov (United States)

    Rippel, Wally E.

    1988-01-01

    Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.

  10. Effective switching frequency multiplier inverter

    Science.gov (United States)

    Su, Gui-Jia; Peng, Fang Z.

    2007-08-07

    A switching frequency multiplier inverter for low inductance machines that uses parallel connection of switches and each switch is independently controlled according to a pulse width modulation scheme. The effective switching frequency is multiplied by the number of switches connected in parallel while each individual switch operates within its limit of switching frequency. This technique can also be used for other power converters such as DC/DC, AC/DC converters.

  11. Inverter design for four-wire microgrids

    OpenAIRE

    Heredero Peris, Daniel; Pagès Giménez, Marc; Montesinos Miracle, Daniel

    2015-01-01

    This paper presents a PQ four quadrant four-wire three-phase inverter for microgrids integration. The inverter is based in two full-bridge IGBT modules connected in a three-phase configuration plus a threephase parallelized neutral branch. This topology is galvanically isolated through a single-phase transformer bank. The converter operates as a non-ideal voltage-controlled voltage source inverter under AC droop strategy with hot-swap capability based on a dynamic virtual impedance.

  12. Tako-tsubo cardiomyopathy and post-traumatic stress disorder after a skiing accident: a case report.

    Science.gov (United States)

    Harb, Birgit Maria; Wonisch, Manfred; Fruhwald, Friedrich; Fazekas, Christian

    2015-03-01

    Symptoms of a post-traumatic stress disorder can follow Tako-tsubo cardiomyopathy. This vignette describes such a linkage and exemplifies the risk that these symptoms may remain undetected. After a skiing accident that had evoked existential fear of suffocation, a post-menopausal woman was diagnosed with Tako-tsubo syndrome and myocardial contusion. Symptoms of post-traumatic stress disorder appeared 2 weeks after remission of the cardiomyopathy. Two months later, a psychological assessment was conducted during cardiac rehabilitation. A post-traumatic stress disorder was diagnosed and successfully treated by narrative exposure. This case report suggests that these patients should be informed during the initial hospital stay that post-traumatic stress symptoms could appear. It also suggests including a screening for post-traumatic stress disorder in the follow-up of these patients.

  13. Prevalence and prognostic relevance of atrial fibrillation in patients with Takotsubo syndrome

    DEFF Research Database (Denmark)

    Stiermaier, Thomas; Santoro, Francesco; Eitel, Charlotte

    2017-01-01

    was evaluated in median 2.9years after the acute event. RESULTS: Atrial fibrillation was found in 97 TTS patients (25.1%) and was associated with older age (pventricular ejection fraction (p... fibrillation (35.2% versus 15.3%; hazard ratio 3.02, 95% confidence interval 1.90-4.78; pfibrillation was identified as an independent determinant of outcome even after adjustment for clinical variables, left ventricular functional parameters (ballooning......BACKGROUND: Takotsubo syndrome (TTS) is associated with a considerable risk of complications during the acute phase and substantial long-term mortality rates. Concomitant atrial fibrillation may have an impact on outcome in these patients. Aim of this study was to assess the prevalence...

  14. Apical ballooning with mid-ventricular obstruction: the many faces of Takotsubo cardiomyopathy

    Science.gov (United States)

    Spadotto, Veronica; Elmaghawry, Mohamed; Zorzi, Alessandro; Migliore, Federico; Marra, Martina Perazzolo

    2013-01-01

    Takotsubo cardiomyopathy (TTC) is a transient left ventricular dysfunction due to akinesia of the left-ventricular (LV) mid-apical segments (apical ballooning), which can cause severe reduction in LV systolic function. The typical clinical picture of TTC include chest pain, electrocardiographic changes consisting of mild ST-segment elevation followed by diffuse deep T-wave inversion, QTc interval prolongation and mild troponin release in the absence of significant coronary stenoses. The syndrome often affects post-menopausal women and is triggered by sympathetic overstimulation, like intense physical or emotional stress, so that it is called the “broken heart syndrome”. Although left-ventricular systolic dysfunction usually fully recovers within few days, heart failure can still complicate the early phase. We report a case of stress-induced cardiomyopathy that had full recovery after 4 weeks of follow up. The main electrocardiographic, angiographic and imaging features are discussed. PMID:24689016

  15. Takotsubo cardiomyopathy following recurrent doses of albuterol due to asthma attack: a very rare case report.

    Science.gov (United States)

    Parsa, Saeed Alipour; Khaheshi, Isa; Memaryan, Mehdi; Naderian, Mohammadreza

    2016-11-01

    To present an unusual case in order to clarify one of the most important differential diagnoses of ST-elevation myocardial infarction in a postmenopausal woman. A 72-year-old woman with asthma attack and retrosternal chest pain was presented to our emergency unit. She had used albuterol spray ten-times before admission due to accentuated dyspnea. Initial ECG revealed ST-segment elevation in leads V1-V6, I and aVL. Emergent coronary angiography indicated normal coronary arteries, and left ventriculography showed significant akinesia of apical segments. This unusual case emphasizes the fact that emergency physicians and cardiologists should be familiar with Takotsubo cardiomyopathy following overuse of β 2 -agonist due to asthma attack that can mimic ST-elevation myocardial infarction.

  16. Basal hyperaemia is the primary abnormality of perfusion in Takotsubo cardiomyopathy

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Ahtarovski, Kiril Aleksov; Bang, Lia Evi

    2015-01-01

    AIMS: Takotsubo cardiomyopathy (TTC) is characterized by acute completely reversible regional left ventricle (LV) akinesia and decreased tracer uptake in the akinetic region on semi-quantitative perfusion imaging. The latter may be due to normoperfusion of the akinetic mid/apical area and basal...... hyperperfusion. Our aim was to examine abnormalities of perfusion in TTC, and we hypothesized that basal hyperperfusion is the primary perfusion abnormality in the acute state. METHOD AND RESULTS: Twenty-five patients were diagnosed with TTC due to (i) acute onset of symptoms, (ii) typical apical ballooning......-on follow-up. Patients initially had severe heart failure, mid/apical oedema but no infarction, and a rise in cardiac biomarkers. On initial perfusion PET imaging, eight patients appeared to have normal, whereas 17 patients had impaired LV perfusion. In the latter, flow in the basal region was increased...

  17. Improvements in ANIS and inverted sputter sources

    NARCIS (Netherlands)

    Zwol, N.A. van; Vermeer, A.; Strasters, B.A.

    1984-01-01

    In this article two sputter sources, i.e. an ANIS and an inverted sputter source are described. The ANIS has been changed into a SNICS-like configuration and measurements of the output current for different sputter target geometries are presented. In the inverted sputter source an immersion lens was

  18. Hydrodynamics of adiabatic inverted annular flow: an experimental study

    International Nuclear Information System (INIS)

    De Jarlais, G.; Ishii, M.

    1983-01-01

    For low-quality film boiling in tubes or rod bundles, the flow pattern may consist of a liquid jet-like core surrounded by a vapor annulus, i.e., inverted annular flow. The stability, shape, and break-up mechanisms of this liquid core must be understood in order to model correctly this regime and to develop appropriate interfacial transfer correlations. This paper reports on a study in which inverted annular flow was simulated in an adiabatic system. Turbulent water jets, issuing downward from long-aspect nozzles were enclosed within cocurrent gas annuli. Jet-core diameter and velocity, and gas-annulus diameter, velocity, and species were varied, yielding liquid Reynolds numbers up to 33,000, void fractions from 0.29 to 0.95, and relative velocities from near zero to over 80 m/s. Jet-core break-up lengths and secondarily, core break-up mechanisms, were observed visually, using strobe lighting

  19. Takotsubo Cardiomyopathy With Significant Coronary Stenosis and Atrioventricular Conduction Block: A Rare Case Report With 3 Year Follow-Up

    OpenAIRE

    Saadatifar, Hakimeh; Khoshhal Dehdar, Fahimeh; Saadatifar, Samira; Moshkani Farahani, Maryam

    2015-01-01

    Introduction Takotsubo cardiomyopathy (TCMP) is a rare acute cardiomyopathy characterized by acute chest pain syndrome, similar to myocardial infarction, except that no significant stenosis is observed on coronary angiography in patients with this condition; these findings aid the diagnosis of TCMP. Case Presentation We discuss an unusual case of TCMP in a 45-year-old woman with complete heart block and significant coronary artery...

  20. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...... to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault....

  1. Inverted base pavements: construction and performance

    KAUST Repository

    Papadopoulos, Efthymios

    2017-05-11

    Inverted base pavements involve a well-compacted granular aggregate base built between a thin asphalt concrete layer and a cement-treated base. Inverted base pavements can be constructed using conventional equipment and procedures but require proper quality control. This study reviews the extensive South African experience and case histories in the USA. Accumulating evidence suggests that inverted base pavements are a viable alternative and can outperform conventional pavements at a lower cost. Inverted base pavements rely on the complementary interaction between layers. The cement-treated base provides a stiff foundation for efficient compaction and constrains the deformation of the stress-sensitive granular aggregate base. The thin asphalt surface layer deforms as a membrane and develops low tensile stress. Additional large-scale field tests should be conducted to assess the performance of inverted base pavement designs in a wide range of conditions relevant to the USA.

  2. Smart Inverter Control and Operation for Distributed Energy Resources

    Science.gov (United States)

    Tazay, Ahmad F.

    the microgrid as well as solve specific issues of connecting the microgrid to the system. A detailed procedure for controlling VSC and designing an optimal operation of the controller is also covered in the first part of the dissertation. This section provides an optimal operation for controlling motor drive and demonstrates issues when motor load exists at an autonomous microgrid. It also provides a solution for specific issues at operating a microgrid at autonomous mode as well as improving the structural design for the grid-tied microgrid. The solution for autonomous microgrid includes changing the operational state of the switching pattern of the smart inverter to solve the issue of a common mode voltage (CMV) that appears across the motor load. It also solves the issue of power supplying to large loads, such as induction motors. The last section of the low-level section involves an improvement of the performance and operation of the PV charging station for a plug-in hybrid electric vehicle (PHEV) at grid-tied mode. This section provides a novel structure and smart controller for PV charging station using three-phase hybrid boost converter topology. It also provides a form of applications of a multifunction smart inverter using PV charging station. The second part of the research is focusing on improving the performance of the microgrid by integrating several smart inverters to form a microgrid. It investigates the issue of connecting DER units with the microgrid at real applications. One of the common issues of the microgrid is the circulating current which is caused by poor reactive power sharing accuracy. When more than two DER units are connected in parallel, a microgrid is forming be generating required power for the load. When the microgrid is operated at autonomous mode, all DER units participate in generating voltage and frequency as well as share the load's power. This section provides a smart and novel controlling technique to solve the issue of unequal

  3. Inverted Lymphoglandular Polyp in Descending Colon

    Directory of Open Access Journals (Sweden)

    Shengmei Zhou

    2015-01-01

    Full Text Available A 47-year-old male with a history of left colon cancer, status post left colon resection for 12 years, presented with rectal bleeding. Colonoscopic examination revealed an 8 mm sessile polyp in the proximal descending colon. Microscopic examination showed that the surface of this polyp was covered with a layer of normal colonic mucosa with focal surface erosion. In the submucosal layer, an intimate admixture of multiple cystically dilated glands and prominent lymphoid aggregates with germinal centers was seen. The glands were lined by columnar epithelium. Immunohistochemical staining showed the glands were positive for CK20 and CDX2 and negative for CK7, with a low proliferative index, mostly consistent with reactive colonic glands. The patient remained asymptomatic after one-year follow-up. A review of the literature shows very rare descriptions of similar lesions, but none fits exactly this pattern. We would designate this inverted lymphoglandular polyp and present this case to raise the awareness of recognizing this unusual histological entity.

  4. Static Characteristics of the Ferroelectric Transistor Inverter

    Science.gov (United States)

    Mitchell, Cody; Laws, crystal; MacLeond, Todd C.; Ho, Fat D.

    2010-01-01

    The inverter is one of the most fundamental building blocks of digital logic, and it can be used as the foundation for understanding more complex logic gates and circuits. This paper presents the characteristics of an inverter circuit using a ferroelectric field-effect transistor. The voltage transfer characteristics are analyzed with respect to varying parameters such as supply voltage, input voltage, and load resistance. The effects of the ferroelectric layer between the gate and semiconductor are examined, and comparisons are made between the inverters using ferroelectric transistors and those using traditional MOSFETs.

  5. Switching Characteristics of Ferroelectric Transistor Inverters

    Science.gov (United States)

    Laws, Crystal; Mitchell, Coey; MacLeod, Todd C.; Ho, Fat D.

    2010-01-01

    This paper presents the switching characteristics of an inverter circuit using a ferroelectric field effect transistor, FeFET. The propagation delay time characteristics, phl and plh are presented along with the output voltage rise and fall times, rise and fall. The propagation delay is the time-delay between the V50% transitions of the input and output voltages. The rise and fall times are the times required for the output voltages to transition between the voltage levels V10% and V90%. Comparisons are made between the MOSFET inverter and the ferroelectric transistor inverter.

  6. Inverted CERN School of Computing

    CERN Document Server

    IT Department

    2011-01-01

      The 5th edition of the Inverted CERN School of Computing (iCSC, “Where students turn into teachers”) will take place next Thursday and Friday (3 and 4 of March) at CERN, Building 31 - IT Amphitheatre - Third Floor. Attendance is free and open to everyone. The programme is designed so that you can attend the lectures that interest you. This year highlights: Cloud Computing, Software Engineering, Cryptography Registration is not mandatory, but will allow you to obtain a copy of the full booklet (first registered, first served). Programme overview: Thursday 3 March 2011 10:00 - 10:15 Introduction School opening 10:15 - 11:10 Lecture 1 Virtualization: what it is, how it works – Luigi Gallerani 11:20 - 12:15 Lecture 2 Server Virtualization at work – Carlos Garcia Fernandez 14:00 - 14:55 Lecture 3 Unweaving Clouds: Principles and Practice – Belmiro Moreira 15:30 - 16:25 Lecture 4 Understanding Cryptography: From Caesar to Public-Key – Nicola...

  7. Cascaded impedance networks for NPC inverter

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    Multilevel inverters are getting more and more attracted because they have better output waveform quality and lower semiconductor voltage stress. The Z-source NPC is a kind of single stage multilevel inverter which has the ability of voltage boost. But the boost capability is relatively low when...... they are subject to the renewable sources. To date, three distinct types of impedance networks can be summarized for implementing a hybrid source impedance network, which can in principle be combined and cascaded before connected to a NPC inverter by proposed two ways. The resulting cascaded impedance network NPC...... would have a higher output voltage gain. It is anticipated that it would help the formed inverters find applications in photovoltaic and other renewable systems, where a high voltage gain is usually requested. Experimental testing has already been conducted and verifies the theory....

  8. Integrated Inverter For Driving Multiple Electric Machines

    Science.gov (United States)

    Su, Gui-Jia [Knoxville, TN; Hsu, John S [Oak Ridge, TN

    2006-04-04

    An electric machine drive (50) has a plurality of inverters (50a, 50b) for controlling respective electric machines (57, 62), which may include a three-phase main traction machine (57) and two-phase accessory machines (62) in a hybrid or electric vehicle. The drive (50) has a common control section (53, 54) for controlling the plurality of inverters (50a, 50b) with only one microelectronic processor (54) for controlling the plurality of inverters (50a, 50b), only one gate driver circuit (53) for controlling conduction of semiconductor switches (S1-S10) in the plurality of inverters (50a, 50b), and also includes a common dc bus (70), a common dc bus filtering capacitor (C1) and a common dc bus voltage sensor (67). The electric machines (57, 62) may be synchronous machines, induction machines, or PM machines and may be operated in a motoring mode or a generating mode.

  9. Performance analysis of new type grid-tied inverter-Aalborg Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Wang, Zhen; Ji, Junhao

    2014-01-01

    Aalborg Inverter is a grid-tied DC/AC inverter. In order to optimize the design, its power losses are analyzed in detail, combined with a description of the single-phase operating principle and the modulation strategy. A 2 kW / 220 V experimental prototype is constructed to verify the theoretical...... analysis. It is concluded that a minimize inductance in the power loop does help the inverter to achieve the high efficiency with the good dynamic performance....

  10. Improvements in ANIS and inverted sputter sources

    Science.gov (United States)

    Strasters, B. A.; Vermeer, A.; van Zwol, N. A.

    1984-02-01

    In this article two sputter sources, i.e. an ANIS and an inverted sputter source are described. The ANIS has been changed into a SNICS-like configuration and measurements of the output current for different sputter target geometries are presented. In the inverted sputter source an immersion lens was placed between the ionizer and the sputter target. This source is provided with a modified revolving target head with eight targets.

  11. Inverted mesiodens--a case report.

    Science.gov (United States)

    Nikhil, S; Vineeta; Gupta, P

    1999-09-01

    A nine and a half years old female school child was examined in a during routine dental examination. The patient had swelling over maxillary midline area just near the labial frenum. Both the central incisors were in position. Radiographic examination revealed presence of an inverted supernumerary tooth between the roots of the central incisors. Surgical extraction of the supernumerary was planned. A unique case of inverted (upside down) mesiodens is presented.

  12. Automatic load sharing in inverter modules

    Science.gov (United States)

    Nagano, S.

    1979-01-01

    Active feedback loads transistor equally with little power loss. Circuit is suitable for balancing modular inverters in spacecraft, computer power supplies, solar-electric power generators, and electric vehicles. Current-balancing circuit senses differences between collector current for power transistor and average value of load currents for all power transistors. Principle is effective not only in fixed duty-cycle inverters but also in converters operating at variable duty cycles.

  13. Base drive for paralleled inverter systems

    Science.gov (United States)

    Nagano, S. (Inventor)

    1980-01-01

    In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules protection against open or short circuit faults occurring in any of the modules, and force equal current sharing among the modules during turn on of the power transistors.

  14. DISCINESIA ÁNTERO-APICAL TRANSITORIA O SÍNDROME DE TAKO-TSUBO. PRESENTACIÓN DE UN CASO / Transient antero-apical dyskinesia or tako-tsubo syndrome. A case report

    Directory of Open Access Journals (Sweden)

    Dayán A. García Cuesta

    2011-09-01

    Full Text Available Transient apical ballooning, Tako-tsubo syndrome (and other synonyms, is a clinical condition first described in Japan, and then in other countries, that mimics acute myocardial infarction. Disorders of left ventricular contractility recover within a few weeks. The fatality rate is very low compared with infarction, but it should be known by professionals that see patients with acute coronary syndrome in the emergency department. A patient who was discharged from our department with this diagnosis is presented, and electrocardiographic, echocardiographic and angiographic images are shown.

  15. Management of Takotsubo cardiomyopathy in non-academic hospitals in France: The Observational French SyndromEs of TakoTsubo (OFSETT) study.

    Science.gov (United States)

    Yayehd, Komlavi; N'da, N'kenon W; Belle, Loïc; Bataille, Vincent; Hanssen, Michel; Leddet, Pierre; Aupetit, Jean-François; Commeau, Philippe; Filippi, Emmanuelle; Georges, Jean-Louis; Albert, Franck; Rangé, Grégoire; Meimoun, Patrick; Marcaggi, Xavier; Baleynaud, Serge; Nallet, Olivier; Dibie, Alain; Barnay, Claude; Jouve, Bernard; Legrand, Maud; Cattan, Simon; Mulak, Geneviève; Simon, Tabassome; Danchin, Nicolas; Dujardin, Jean-Jacques

    2016-01-01

    Takotsubo cardiomyopathy (TTC) is a rare condition characterized by a sudden temporary weakening of the heart. TTC can mimic acute myocardial infarction and is associated with a minimal release of myocardial biomarkers in the absence of obstructive coronary artery disease. To provide an extensive description of patients admitted to hospital for TTC throughout France and to study the management and outcomes of these patients. In 14 non-academic hospitals, we collected clinical, electrocardiographic, biological, psychological and therapeutic data in patients with a diagnosis of TTC according to the Mayo Clinic criteria. Of 117 patients, 91.5% were women, mean ± SD age was 71.4 ± 12.1 years and the prevalence of risk factors was high (hypertension: 57.9%, dyslipidaemia: 33.0%, diabetes: 11.5%, obesity: 11.5%). The most common initial symptoms were chest pain (80.5%) and dyspnoea (24.1%). A triggering psychological event was detected in 64.3% of patients. ST-segment elevation was found in 41.7% of patients and T-wave inversion in 71.6%. Anterior leads were most frequently associated with ST-segment elevation, whereas T-wave inversion was more commonly associated with lateral leads, and Q-waves with septal leads. The ratio of peak B-type natriuretic peptide (BNP) or N-terminal prohormone BNP (NT-proBNP) level to peak troponin level was 1.01. No deaths occurred during the hospital phase. After 1 year of follow-up, 3 of 109 (2.8%) patients with available data died, including one cardiovascular death. Rehospitalizations occurred in 17.4% of patients: 2.8% due to acute heart failure and 14.7% due to non-cardiovascular causes. There was no recurrence of TTC. This observational study of TTC included primarily women with atherosclerotic risk factors and mental stress. T-wave inversion was more common than ST-segment elevation. There were few adverse cardiovascular outcomes in these patients after 1-year follow-up. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Takotsubo cardiomyopathy precipitated by negative pressure pulmonary oedema following total thyroidectomy

    Directory of Open Access Journals (Sweden)

    K S Bharathi

    2016-01-01

    Full Text Available 'Takotsubo cardiomyopathy (TCM' or 'stress cardiomyopathy' is a reversible cardiomyopathy that is precipitated by intense emotional or physical stress. This syndrome is characterised by symptoms mimicking acute coronary syndrome with transient systolic dysfunction associated with regional wall motion abnormalities, which extend beyond a single coronary vascular bed in the absence of obstructive coronary vascular disease. The presentation of TCM and myocardial infarction is similar with sudden onset of chest pain, breathlessness as well as abnormalities in both the electrocardiogram and cardiac enzymes. It is difficult to differentiate between the two until cardiac catheterisation establishes the diagnosis. We report a case of TCM in a post-menopausal female, precipitated by negative pressure pulmonary oedema following total thyroidectomy in whom timely cardiac catheterisation established the diagnosis and influenced the management. Heightened awareness of this unique cardiomyopathy is essential to have a high index of suspicion in at-risk population for the prompt diagnosis of stress-related cardiomyopathy syndromes occurring in the perioperative period.

  17. Recurrent Direct Current Cardioversion Induced Takotsubo Cardiomyopathy. A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Athanasios Smyrlis

    2015-01-01

    Full Text Available Stress cardiomyopathy (SCM, also called broken heart syndrome and Takotsubo cardiomyopathy is an increasingly reported syndrome generally characterized by transient systolic dysfunction of the apical and or mid segments of the left ventricle that mimics myocardial infarction, in the absence of obstructive coronary artery disease. Typically patients present within a few hours of exposure to physical or emotional stress. However, the mechanism by which these stressors result in myocardial dysfunction is unclear. Proposed factors include catecholamine excess and coronary vasospasm1. We present the case of a 61-year-old female who experienced acute pulmonary edema secondary to stress cardiomyopathy, on two occasions immediately after undergoing elective direct current cardioversion (DCCV for atrial fibrillation (Afib. After an urgent hospitalization for management of acute left ventricular failure, she made a complete clinical and echocardiographic recovery. The incidence, clinical implications and prognosis of DCCV induced SCM is unknown. Given DCCV for Afib is a common outpatient procedure and DCCV induced SCM can lead to acute clinical deterioration it is important that physicians are vigilant about this newly recognized DCCV complication.

  18. Takotsubo cardiomyopathy precipitated by maxillofacial surgery and general anesthesia: a case report and review of literature.

    Science.gov (United States)

    Bruckman, Karl C; Taub, Daniel I; McNulty, Stephen E

    2013-12-01

    Takotsubo cardiomyopathy (TCM) is a syndrome characterized by a transient episode of heart failure. The specific etiology of this condition is widely speculated. The purpose of this case report and literature review was to investigate the incidence of TCM with regard to general anesthesia, especially those cases involving operative procedures within the realm of oral and maxillofacial surgery. It is intended that the present case serve as a guide for fellow surgeons to identify and manage this syndrome. The present case was explained and a review of the literature was performed. PubMed was used to search for articles involving surgical procedures under general anesthesia, including oral and maxillofacial surgery. It was determined that TCM rarely occurs in conjunction with surgical procedures under general anesthesia, especially those of the head and neck region. TCM is an uncommon medical condition with significant morbidity and mortality when managed incorrectly. The occurrence of this syndrome in relation to oral and maxillofacial procedures is also rare, although it is imperative that surgeons be able to recognize and treat this condition appropriately. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Takotsubo Cardiomyopathy after Spinal Anesthesia for a Minimally Invasive Urologic Procedure

    Directory of Open Access Journals (Sweden)

    Emmanuel Lilitsis

    2017-01-01

    Full Text Available We present the case of a patient who suffered from Takotsubo cardiomyopathy (TCM immediately after the initiation of subarachnoid anesthesia for a minimally invasive urologic procedure (tension-free vaginal tape (TVT surgery for stress urine incontinence. TCM mimics acute coronary syndrome and is caused by an exaggerated sympathetic reaction to significant emotional or physical stress. Our patient suffered from chest pain, palpitations, dyspnea, and hemodynamic instability immediately following subarachnoid anesthesia and later in the postanesthesia care unit. Blood troponin was elevated and new electrocardiographic changes appeared indicative of cardiac ischemia. Cardiac ultrasound indicated left ventricular apical akinesia and ballooning with severely affected contractility. The patient was admitted to coronary intensive care for the proper care and finally was discharged. TCM was attributed to high emotional preoperative stress for which no premedication had been administered to the patient. In conclusion, adequate premedication and anxiety management are not only a measure to alleviate psychological stress of surgical patients, but, more importantly, an imperative mean to suppress sympathetic nerve system response and its cardiovascular consequences.

  20. Comparison and Outcome Analysis of Patients with Takotsubo Cardiomyopathy Triggered by Emotional Stress or Physical Stress

    Directory of Open Access Journals (Sweden)

    Konstantinos Giannakopoulos

    2017-04-01

    Full Text Available Background: Previous studies revealed that takotsubo cardiomyopathy (TTC is triggered by physical and emotional stresses. This study was performed to determine the short- and long-term prognostic impact of emotional- and physical stress associated with TTC.Methods and results: Our institutional database constituted a collective of 84 patients diagnosed with TTC between 2003 and 2015. The patients were divided into two groups as per the presence of emotional stress (n = 24, 21% or physical stress (n = 60, 52.6%. The endpoint was a composite of in-hospital events (thromboembolic events and life-threatening arrhythmias, myocardial infarction, all-cause of mortality, re-hospitalization due to heart failure, stroke, and recurrence of TTC. A Kaplan–Meier analysis indicated a significantly lower event-free survival rate over a mean follow-up of 5 years in the emotional group than the physical stress group (log-rank, p < 0.01. Multivariate Cox regression analysis revealed only emotional stress (HR 0.4, 95% CI: 0.2–0.9, p < 0.05 as a negative independent predictor of the primary endpoint.Conclusion: Rates of in-hospital events and short- as well as long-term events were significantly lower in TTC patients suffering from emotional stress as compared to patients with physical stress.

  1. Is it possible to differentiate between Takotsubo cardiomyopathy and acute anterior ST-elevation myocardial infarction?

    DEFF Research Database (Denmark)

    Vervaat, Fabienne E; Christensen, Thomas E; Smeijers, Loes

    2015-01-01

    INTRODUCTION: Several studies have investigated the ability of the twelve-lead electrocardiogram (ECG) to reliably distinguish Takotsubo cardiomyopathy (TC) from an acute anterior ST-segment elevation myocardial infarction (STEMI). In these studies, only ECG changes were required - ST-segment dev...... insufficient to reliably distinguish patients with TC from patients with an acute anterior STEMI. To definitely exclude the diagnosis of an acute anterior STEMI coronary angiography, which remains the gold standard, will need to be performed.......-segment deviation and/or T-wave inversion - in TC whereas in acute anterior STEMI, ECGs had to meet STEMI criteria. In the majority of these studies, patients of both genders were used even though TC predominantly occurs in women. The aim of this study is to see whether TC can be distinguished from acute anterior......VR+ST-segment elevation ≤1mm in lead V1, (2) frontal plane ST-vector and (3) mean amplitude of ST-segment deviation in each lead. RESULTS: The existing ECG criterion was less accurate (76%) than in the original study (95%), with a large difference in sensitivity (26% vs. 91%). Only a frontal plane ST-vector of 60° could...

  2. Takotsubo cardiomyopathy associated with Guillain-Barré syndrome: a differential diagnosis from dysautonomia not to be missed.

    Science.gov (United States)

    Martins, Raphaël Pedro; Barbarot, Nicolas; Coquerel, Nicolas; Baruteau, Alban-Elouen; Kolev, Ivan; Vérin, Marc

    2010-04-15

    A 60-year-old woman presented with a 1-week progressive limb weakness and an areflexic tetraparesis. Both neurophysiological and cerebrospinal fluid examinations were consistent with diagnosis of Guillain-Barré syndrome (GBS) and a treatment by intravenous immunoglobulin over a 5-day period was started. At the end of the treatment, the patient suffered from an acute coronary syndrome (ACS) without stenosis at coronary arteriography. Left ventriculography showed segmental wall motion abnormalities with apical akinesis contrasting with hyperkinesis in basal segments, with a depressed left ventricular ejection fraction at 45%. Cardiac magnetic resonance imaging excluded the diagnosis of myocarditis. A diagnosis of "transient left ventricular apical ballooning syndrome" or "Takotsubo" syndrome was then made and a treatment by angiotensin-converting enzyme inhibitor and beta-blocker was introduced. Left ventricular dysfunction and electrocardiogram normalized within two weeks and the patient remained free from cardiovascular events at one year of follow-up. This cardiomyopathy is a recently known and now commonly diagnosed reversible systolic dysfunction mimicking ACS and is secondary to physical or emotional stress affecting mainly post-menopausal women. Electrocardiographic and echocardiographic abnormalities are often regressive in days or weeks, and rarely responsible for complications. This observation supports clinical evidence that electrocardiographic changes in GBS can be linked to Takotsubo syndrome, by means of the stressful trigger of GBS occurrence. This reversible cardiomyopathy needs adequate management and specific therapeutic strategies. Therefore, trans-thoracic echocardiography should be systematically performed when repolarisation abnormalities are present in this disease to rule out a Takotsubo syndrome, even in asymptomatic patients. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Cardiomiopatía inducida por estrés (Takotsubo en una paciente con anorexia nerviosa

    Directory of Open Access Journals (Sweden)

    Sabrina Vadalá

    2014-06-01

    Full Text Available Presentamos el caso de una mujer con diagnóstico de anorexia nerviosa que desarrolló cardiomiopatía de takotsubo precipitada por estrés emocional y alteraciones del medio interno. Evolucionó favorablemente con manejo conservador. Los casos de cardiomiopatía inducida por estrés, descriptos en pacientes con trastornos de la conducta alimentaria, suelen alcanzar mayor gravedad y se asocian con la prolongación del intervalo QT por desequilibrios electrolíticos, arritmias ventriculares e hipoglucemia. Se realiza una revisión del compromiso cardiovascular en pacientes con anorexia nerviosa.

  4. Cardiomiopatía inducida por estrés (Takotsubo) en una paciente con anorexia nerviosa

    OpenAIRE

    Sabrina Vadalá; Débora Pellegrini; María Fernanda Verdaguer; Marcela Schrappe; José Álvarez; Julio E. Bruetman

    2014-01-01

    Presentamos el caso de una mujer con diagnóstico de anorexia nerviosa que desarrolló cardiomiopatía de takotsubo precipitada por estrés emocional y alteraciones del medio interno. Evolucionó favorablemente con manejo conservador. Los casos de cardiomiopatía inducida por estrés, descriptos en pacientes con trastornos de la conducta alimentaria, suelen alcanzar mayor gravedad y se asocian con la prolongación del intervalo QT por desequilibrios electrolíticos, arritmias ventriculares e hipogluce...

  5. Inverter for Installations with Intermittent Electricity Production

    Directory of Open Access Journals (Sweden)

    Ermuraki Iu.

    2016-04-01

    Full Text Available A new architecture of the inverter used in the convertion of electric energy generated by renewable energy sources is studied in this paper. The distinctive features of this inverter is the special block which compensates pulsing of the current with double frequency, characteristic for these inverters. The switching of electronic keys is realized using the method TCM In this block, like in the inverter, which assures the switching at the voltages near to zero (ZVC. The proposed algorithm of controlling the electronic keys permits to increase the work frequency up to hundreds of kHz. Electronic keys operate at variable frequency, which changes during the work cycle both slowly and by jump. The assurance of admissible heat regime is performed using forced cooling air flux and by convection. The increase of releasing process of the heat is assured by original construction of radiators which forms the turbulent mode of cooling air flux. These changes of the architecture of the inverter have allowed the minimization of mass, sizes and price indicators. It has been manufactured a functional laboratory sample with output power of 2kW the voltage of direct current of 450V or 48 V and output alternating voltage of 230V, with sizes 175mmX35mmX30mm.

  6. Cascades of alternating pitchfork and flip bifurcations in H-bridge inverters

    DEFF Research Database (Denmark)

    Avrutin, Viktor; Zhusubaliyev, Zhanybai T.; Mosekilde, Erik

    2017-01-01

    -phase inverter, the present paper discusses a number of unusual phenomena that can occur in piecewise smooth maps with a very large number of switching manifolds. We show in particular how smooth (pitchfork and flip) bifurcations may form a macroscopic pattern that stretches across the overall bifurcation...

  7. Toddlers with Williams Syndrome Process Upright but Not Inverted Faces Holistically

    Science.gov (United States)

    Cashon, Cara H.; Ha, Oh-Ryeong; DeNicola, Christopher A.; Mervis, Carolyn B.

    2013-01-01

    Holistic processing of upright, but not inverted, faces is a marker of perceptual expertise for faces. This pattern is shown by typically developing individuals beginning at age 7 months. Williams syndrome (WS) is a rare neurogenetic developmental disorder characterized by extreme interest in faces from a very young age. Research on the effects of…

  8. Serotonin norepinephrine re-uptake inhibitor (SNRI)-, selective norepinephrine reuptake inhibitor (S-NRI)-, and exogenously administered norepinephrine-induced takotsubo syndrome: Analysis of published cases.

    Science.gov (United States)

    Y-Hassan, Shams

    2017-03-15

    Takotsubo syndrome (TS) may be triggered by numerous physical stress factors including exogenous Norepinephrine administration. The aim of this study is to report on the clinical features and outcome of serotonin-norepinephrine reuptake inhibitor (SNRI)-, selective NRI (S-NRI)-, and exogenously administered norepinephrine-induced TS in a largest possible cohort of published cases. A computer assisted search of the electronic data base Pubmed was performed from 1990 to August 2016. All cases deemed to have SNRI-, S-NRI-, and norepinephrine-induced TS were retrieved. Twenty two cases of SNRI-, S-NRI-, and norepinephrine-induced TS were retrieved from the literature. At presentation, the 22 patients with TS were 11 to 82years of age (mean age 49.9±20years). Seventeen of 21 (81%) of the patients were women. The most common presenting symptom was chest pain, which occurred in 59% of cases. The TS localization pattern was apical in 68%, mid-ventricular in 13.6%, basal in 13.6% and global in 4.5% of cases. Complications occurred in 7 of 22 (32%) with more complications in exogenously administered norepinephrine-induced TS (4 of 6, 66.7%) than SNRI-, and S-NRI-induced TS (3 of 16, 18, 8%) (p=0.054). All 4 male patients in the study developed complications. One patient (exogenous norepinephrine-induced TS) died during hospitalization. The SNRI-, and S-NRI-induced TS have clinical features, complications and course comparable to that of all-TS population cohorts, whereas the exogenously administered norepinephrine-induced TS has a more dramatic clinical presentation and complication rates, which resembles that of exogenously administered epinephrine-induced TS. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Addressable inverter matrix for process and device characterization

    Science.gov (United States)

    Buehler, M. G.; Sayah, H. R.

    1985-01-01

    The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold vltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.

  10. Estudo comparativo da cicatrização de enterorrafias em planos aposicional e invaginante no cólon descendente de eqüinos Comparative study between appositional and inverting pattern for closure of descending colon enterotomies in equines

    Directory of Open Access Journals (Sweden)

    F.A. Lucas

    2001-10-01

    Full Text Available O estudo foi conduzido com o objetivo de comparar o processo cicatricial do cólon descendente de eqüinos, quando submetido a duas técnicas de sutura, uma em plano aposicional e outra em dois planos com invaginação. Foram utilizados 15 eqüinos sadios e a intervenção cirúrgica foi realizada com os animais em decúbito lateral direito, sob anestesia geral inalatória. O acesso à cavidade abdominal foi feito pelo flanco esquerdo, e após exteriorização do cólon descendente, realizaram-se duas enterotomias de 5cm de extensão cada, distanciadas 20cm uma da outra. Os animais foram aleatoriamente distribuídos em cinco grupos de três animais cada e sacrificados aos 3, 7, 14, 21 e 35 dias pós-operatório. O exame necroscópico revelou presença de aderências nos dois padrões de sutura. Em nove eqüinos foram observadas aderências no padrão de sutura aposicional (60,0% ± 12,6 e em quatro no padrão com invaginação (26,6 % ± 11,4. Não foi verificada interferência com o trânsito intestinal em nenhum paciente. O exame histopatológico revelou regeneração da camada mucosa a partir do sétimo dia de pós-operatório em ambos os tipos de sutura. O fio de poliglactina 910 empregado nas enterorrafias do cólon descendente se mostrou resistente, de fácil manuseio e com boa capacidade para manter os nós aplicados, causando moderada reação inflamatória do tipo granulomatosa.This trial was carried out in order to compare the healing process of the descending colon in horses, submitted to two distinctive suture techniques - appositional pattern and inverting pattern. Fifteen healthy horses were used and the surgical intervention was accomplished with the animals in right lateral recumbency, under inhalatory anesthesia. The abdominal cavity approach was done by the left flank, and after exteriorization of the descending colon, two enterotomies, 5cm long, and 20cm apart one from each other were done. The horses were randomly distributed

  11. An SCR inverter for electric vehicles

    Science.gov (United States)

    Latos, T.; Bosack, D.; Ehrlich, R.; Jahns, T.; Mezera, J.; Thimmesch, D.

    1980-01-01

    An inverter for an electric vehicle propulsion application has been designed and constructed to excite a polyphase induction motor from a fixed propulsion battery source. The inverter, rated at 35kW peak power, is fully regenerative and permits vehicle operation in both the forward and reverse directions. Thyristors are employed as the power switching devices arranged in a dc bus commutated topology. This paper describes the major role the controller plays in generating the motor excitation voltage and frequency to deliver performance similar to dc systems. Motoring efficiency test data for the controller are presented. It is concluded that an SCR inverter in conjunction with an ac induction motor is a viable alternative to present dc vehicle propulsion systems on the basis of performance and size criteria.

  12. Smart Inverters for Utility and Industry Applications

    DEFF Research Database (Denmark)

    Xue, Yaosuo; Guerrero, Josep M.

    2015-01-01

    Smart inverters are emerging with increasing renewable energy and smart grid development. While the recent work reviewed mostly focuses on defining standardized control functionalities and smart grid communication protocols, we take a holistic approach in this paper and propose a holon-type smart...... inverter concept, which features autonomous, adaptive, cooperative and plug-and-play functions. Self-awareness is also continually driven by power electronics inherently. These features can be favorable in a complex environment with more and more small-scale power electronics-based devices, and can reduce...

  13. Asymmetrical transformer-based embedded Z-source inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source inverters are inverters with buck-boost capability that traditional inverters cannot match. Despite this ability, present Z-source topologies are burdened by some limitations such as chopping input current, high-voltage stress and poor spectral performance at high gain. To improve...... their performances, a number of asymmetrical transformer-based embedded Z-source inverters are proposed. Through theoretical derivation and experiments, the proposed inverters have been shown to draw a smooth input current and produce a high gain by varying the transformer turns ratio n. The range of variation for n...... depends on the inverter topology chosen, which in turn depends on the application under consideration....

  14. Characteristics Comparison of High-Frequency Multi-Level Inverter Connected with Filter Inverters

    Science.gov (United States)

    Iwaya, Kazuki; Noguchi, Toshihiko

    This paper presents characteristics comparison of a high-frequency multi-level inverter connected with small capacity filter inverters. In general, PWM inverters require a low-pass filter in order to reduce switching harmonics. However, in the high-frequency systems such as class D power amplifiers, the cut-off frequency of the low-pass filter must set at high frequency. Thus, harmonic distortion of the output voltage harmfully enlarges. Increasing the number of output voltage levels is effective to reduce the harmonic distortion of the output voltage and the low-pass filter size. The proposed systems consist of a 5-level inverter and several cascade-connected low-voltage full bridge inverters without any external DC power sources for filtering the output voltage. The 5-level inverter generates a stepwise waveform with 5-level voltage, and the low voltage filter inverter superimposes harmonic components to compensate for the voltage waveform distortion. Therefore, the proposed system can reduce its total switching loss and can increase the number of the output voltage levels. In this paper, effectiveness of the proposed systems is verified through several experiments.

  15. Fast Self-Synchronization between LowVoltage Microgrid and Inverter using Virtual Synchronous Converter

    Directory of Open Access Journals (Sweden)

    Md Ruhul Amin

    2017-12-01

    Full Text Available In this paper, a fast self-synchronization known as virtual synchronous converter (VSCon between single-phase microgrid and inverter in low-voltage microgrid, has been developed in Matlab/Simulink. The idea is to any phase locked loop (PLL circuit for inverter-microgrid synchronization in order to improve the synchronization time. As known, it is difficult and lengthy process to tune the PLL gain parameters to reach suitable performance for synchronizing among the voltage, phase-angle and frequency between them. Due to this problem, a fast self synchronization technique is needed in order to minimize the time losses at the microgrid connection. Therefore, the VSCon has been developed which is based on the synchronous generator mathematical model but in virtual environment representation. It has been applied in the inverter control for generating switching pattern to the inverter switches in order to respond to the grid voltage for improve the synchronization. For a prove of concept, several simulation tests in MATLAB models have been conducted, in order to see the effectiveness of this VSCon. First test has been conducted, when a 240V, 50Hz frequency grid source is used for observing the self-synchronization the system with the power flows output. Furthermore, the next test is conducted when the grid frequency is changed from the rated frequency at 50Hz to 51Hz and the result shows the VSCon in inverter control takes nearly 40ms to synchronize to this new frequency value. The test on grid phase-angle delay also been tested when ac grid voltage has 150 phase delay. As from all the results, the improved inverter control with VSCon structure is able to have fast and self-synchronized between the invertergrid connection before the power from the inverter can be transferred.

  16. Live Imaging of Shoot Meristems on an Inverted Confocal Microscope Using an Objective Lens Inverter Attachment.

    Science.gov (United States)

    Nimchuk, Zachary L; Perdue, Tony D

    2017-01-01

    Live imaging of above ground meristems can lead to new insights in plant development not possible from static imaging of fixed tissue. The use of an upright confocal microscope offers several technical and biological advantages for live imaging floral or shoot meristems. However, many departments and core facilities possess only inverted confocal microscopes and lack the funding for an additional upright confocal microscope. Here we show that imaging of living apical meristems can be performed on existing inverted confocal microscopes with the use of an affordable and detachable InverterScope accessory.

  17. High voltage series resonant inverter ion engine screen supply. [SCR series resonant inverter for space applications

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Shank, J. H.

    1974-01-01

    A high-voltage, high-power LC series resonant inverter using SCRs has been developed for an Ion Engine Power Processor. The inverter operates within 200-400Vdc with a maximum output power of 2.5kW. The inverter control logic, the screen supply electrical and mechanical characteristics, the efficiency and losses in power components, regulation on the dual feedback principle, the SCR waveforms and the component weight are analyzed. Efficiency of 90.5% and weight density of 4.1kg/kW are obtained.

  18. Processing facial expressions of emotion: upright vs. inverted images

    Directory of Open Access Journals (Sweden)

    David eBimler

    2013-02-01

    Full Text Available We studied discrimination of briefly presented Upright vs. Inverted emotional facial expressions (FEs, hypothesising that inversion would impair emotion decoding by disrupting holistic FE processing. Stimuli were photographs of seven emotion prototypes, of a male and female poser (Ekman and Friesen, 1976, and eight intermediate morphs in each set. Subjects made speeded Same/Different judgements of emotional content for all Upright (U or Inverted (I pairs of FEs, presented for 500 ms, 100 times each pair. Signal Detection Theory revealed the sensitivity measure d' to be slightly but significantly higher for the Upright FEs. In further analysis using multidimensional scaling (MDS, percentages of Same judgements were taken as an index of pairwise perceptual similarity, separately for U and I presentation mode. The outcome was a 4D ‘emotion expression space’, with FEs represented as points and the dimensions identified as Happy–Sad, Surprise/Fear, Disgust and Anger. The solutions for U and I FEs were compared by means of cophenetic and canonical correlation, Procrustes analysis and weighted-Euclidean analysis of individual difference. Differences in discrimination produced by inverting FE stimuli were found to be small and manifested as minor changes in the MDS structure or weights of the dimensions. Solutions differed substantially more between the two posers, however. Notably, for stimuli containing elements of Happiness (whether U or I, the MDS structure revealed some signs of categorical perception, indicating that mouth curvature – the dominant feature conveying Happiness – is visually salient and receives early processing. The findings suggest that for briefly-presented FEs, Same/Different decisions are dominated by low-level visual analysis of abstract patterns of lightness and edge filters, but also reflect emerging featural analysis. These analyses, insensitive to face orientation, enable initial positive/negative Valence

  19. Analysis of Multicarrier PWM techniques for Photovoltaic fed Cascaded H-Bridge Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    VENKATRAMAN Thiyagarajan

    2017-05-01

    Full Text Available Recently multilevel inverter technology emerging as an important alternative in the field of high power, medium voltage energy control. The various topologies for multilevel inverters such as diode-clamped, flying capacitor and cascaded H-bridge have been proposed over the years. This paper analysis the performance of a single phase seven level cascaded H-bridge inverter for photovoltaic applications. The Phase Disposition PWM (PDPWM technique is used to generate gate signals. The performance is compared for both sinusoidal reference waveform and trapezoidal reference waveform. The analysis is carried out for different modulation index and different shading pattern of photovoltaic (PV array. The simulation is carried out using MATLAB/SIMULINK software.

  20. Inverted Pedagogy in Second Semester Calculus

    Science.gov (United States)

    Kennedy, Ellie; Beaudrie, Brian; Ernst, Dana C.; St. Laurent, Roy

    2015-01-01

    This study investigates the effects of applying an inverted classroom model in a second-semester calculus course at a large regional university in the southwest during the Spring of 2013. The sample consisted of four class sections with the same instructor, with a total of 173 students; two class sections were in the experimental group, whereas…

  1. Inverting the Transition-to-Proof Classroom

    Science.gov (United States)

    Talbert, Robert

    2015-01-01

    In this paper, we examine the benefits of employing an inverted or "flipped" class design in a Transition-to-Proof course for second-year mathematics majors. The issues concomitant with such courses, particularly student acquisition of "sociomathematical norms" and self-regulated learning strategies, are discussed along with…

  2. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used...

  3. The Internet and the Inverted Classroom.

    Science.gov (United States)

    Lage, Maureen J.; Platt, Glenn

    2000-01-01

    Describes a Web site that is for an undergraduate principles of microeconomics course and a main component of "The Inverted Classroom" in which lectures take place outside of class. Explains that the Web site is divided into four sections: (1) the classroom; (2) the desk; (3) the coffee shop; and (4) the library. (CMK)

  4. Solar Power Station Output Inverter Control Design

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2011-04-01

    Full Text Available The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system can be used as a generator and it shall deliver energy to the supply network. Each type of the application has different requirements on the converter and its control algorithm. But for all of them the one thing is common – the maximal efficiency. The paper focuses on design and simulation of the low power inverter that acts as output part of the whole converter. In the paper the design of the control algorithm of the inverter for both types of inverter application – for islanding mode and for operation on the supply grid – is discussed. Attention is also paid to the design of the output filter that should reduce negative side effects of the converter on the supply network.

  5. Subintegrality, invertible modules and Laurent polynomial extensions

    Indian Academy of Sciences (India)

    Indian Acad. Sci. (Math. Sci.) Vol. 125, No. 2, May 2015, pp. 149–160. c Indian Academy of Sciences. Subintegrality, invertible modules and Laurent polynomial extensions. VIVEK SADHU. Department of Mathematics ...... comments which have improved the exposition. Further, he would like to thank CSIR,. India for financial ...

  6. Two-Stage Series-Resonant Inverter

    Science.gov (United States)

    Stuart, Thomas A.

    1994-01-01

    Two-stage inverter includes variable-frequency, voltage-regulating first stage and fixed-frequency second stage. Lightweight circuit provides regulated power and is invulnerable to output short circuits. Does not require large capacitor across ac bus, like parallel resonant designs. Particularly suitable for use in ac-power-distribution system of aircraft.

  7. Inverter Matrix for the Clementine Mission

    Science.gov (United States)

    Buehler, M. G.; Blaes, B. R.; Tardio, G.; Soli, G. A.

    1994-01-01

    An inverter matrix test circuit was designed for the Clementine space mission and is built into the RRELAX (Radiation and Reliability Assurance Experiment). The objective is to develop a circuit that will allow the evaluation of the CMOS FETs using a lean data set in the noisy spacecraft environment.

  8. Pulse width modulation inverter with battery charger

    Science.gov (United States)

    Slicker, James M. (Inventor)

    1985-01-01

    An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a flyback DC-DC converter circuit for recharging the battery.

  9. The invertible double of elliptic operators

    DEFF Research Database (Denmark)

    Booss-Bavnbek, Bernhelm; Lesch, Matthias; Zhu, Chaofeng

    We construct a canonical invertible double for general first order elliptic differential operators over smooth compact manifolds with boundary and derive a natural formula for the Calderon projector which yields a generalization of the famous Cobordism Theorem. Assuming symmetric principal symbol...

  10. Left ventricular outflow track obstruction and mitral valve regurgitation in a patient with takotsubo cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yin Wu

    2015-12-01

    Full Text Available Introduction: Takotsubo cardiomyopathy (TCM can be complicated by left ventricular outflow tract (LVOT obstruction and severe acute mitral regurgitation (MR, leading to hemodynamic instability in an otherwise benign disorder. Despite the severity of these complications, there is a paucity of literature on the matter. Because up to 20–25% of TCM patients develop LVOT obstruction and/or MR, it is important to recognize the clinical manifestations of these complications and to adhere to specific management in order to reduce patient morbidity and mortality. We report the clinical history, imaging, treatment strategy, and clinical outcome of a patient with TCM that was complicated with severe MR and LVOT obstruction. We then discuss the pathophysiology, characteristic imaging, key clinical features, and current treatment strategy for this unique patient population. Case report: A postmenopausal woman with no clear risk factor for coronary artery disease (CAD presented to the emergency department with chest pain after an episode of mental/physical stress. Physical examination revealed MR, mild hypotension, and pulmonary vascular congestion. Her troponins were mildly elevated. Cardiac catheterization excluded obstructive CAD, but revealed severe apical hypokinesia and ballooning. Notably, multiple diagnostic tests revealed the presence of severe acute MR and LVOT obstruction. The patient was diagnosed with TCM complicated by underlying MR and LVOT obstruction, and mild hemodynamic instability. The mechanism of her LVOT and MR was attributed to systolic anterior motion of the mitral valve (SAM, which the transesophageal echocardiogram clearly showed during workup. She was treated with beta-blocker, aspirin, and ACE-I with good outcome. Nitroglycerin and inotropes were discontinued and further avoided. Conclusions: Our case illustrated LVOT obstruction and MR associated with underlying SAM in a patient with TCM. LVOT obstruction and MR are severe

  11. Síndrome de Takotsubo: experiencia en tres instituciones de la ciudad de Córdoba

    Directory of Open Access Journals (Sweden)

    Laura Fortuna

    2014-02-01

    Full Text Available Takotsubo es una miocardiopatía adquirida que se caracteriza por la aparición transitoria de acinesia o discinesia antero-apical del ventrículo izquierdo, síntomas y cambios electrocardiográficos que simulan un síndrome coronario agudo, leve elevación de enzimas cardíacas y coronarias sin lesiones ateroscleróticas significativas. Afecta predominantemente a mujeres post menopáusicas y frecuentemente es precedido por situaciones de estrés físico o psicológico. La fisiopatología no ha sido completamente dilucidada pero existe consenso sobre el papel central de la descarga masiva de catecolaminas, secundaria a dichas situaciones de estrés, como mecanismo desencadenante. Se presentan 32 casos diagnosticados en tres instituciones de Córdoba. La edad promedio fue 61 años, el 28 (88% fueron mujeres, y todos se presentaron simulando síndromes coronarios agudos. Doce pacientes (37.5% evolucionaron con insuficiencia cardíaca y dos (6% desarrollaron shock cardiogénico. La función ventricular se normalizó más rápidamente que los cambios electrocardiográficos. La tasa de recurrencia fue del 25%. El pronóstico fue benigno, ya que solo se produjo una muerte como consecuencia de una recidiva. Estos hallazgos son, en general, similares a los publicados en la literatura. También se analizaron recientes progresos sobre la fisiopatología de esta miocardiopatía que permitieron desarrollar un planteo racional de tratamiento.

  12. Simple markers can distinguish Takotsubo cardiomyopathy from ST segment elevation myocardial infarction.

    Science.gov (United States)

    Budnik, Monika; Kochanowski, Janusz; Piatkowski, Radoslaw; Wojtera, Karolina; Peller, Michal; Gaska, Maria; Glowacka, Paulina; Karolczak, Paulina; Ochijewicz, Dorota; Opolski, Grzegorz

    2016-09-15

    Takotsubo cardiomyopathy (TTC) is a clinical condition mimicking acute myocardial infarction. A specific biomarker for TTC screening is required, but until now, no single biomarker has been established for the early diagnosis of TTC and differentiation from ST-segment elevation myocardial infarction (STEMI). In our study we focused on the simple markers that are available in every hospital. In 66 consecutive patients (pts) who were hospitalized with TTC and 66 pts with STEMI, cardiac biomarkers, such as NT-proBNP, TnI, CK and CKMB mass were determined during 12h from admission and compared with demographic, clinical and echocardiographic findings. The concentration of NTproBNP was greater in pts with TTC than STEMI (4702pg/ml vs 2138pg/ml). The concentration of TnI and CKMB mass was greater in the STEMI group than in the TTC group (TnI: 2.1ng/ml and CK MB mass: 9.5ng/ml in pts with TTC vs TnI: 19ng/ml and CK MB mass: 73.3ng/ml in pts with STEMI). The NTproBNP/TnI ratio and NTproBNP/CKMB mass ratio were, respectively, 2235.2 and 678.2 in pts with TTC and 81.6 and 27.5 in pts with STEMI (p<0.001). Moreover, the NTproBNP/EF ratio was also statistically significant (110.4 in TTC group and 39.4 in STEMI group). NTproBNP/TnI, NTproBNP/CKMB mass and NTproBNP/EF ratios can distinguish TTC from STEMI at an early stadium. The most accurate marker is the NTproBNP/TnI ratio. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. FPGA Based Compensation Method for Correcting Distortion in Voltage Inverters

    National Research Council Canada - National Science Library

    Williamson, Kenya D

    2007-01-01

    ...) voltage source inverters. Blanking time distortion is caused by the delay inserted to prevent the short circuit that would occur if the two transistors in the same inverter leg are both on at the same time...

  14. Inverter Anti-Islanding with Advanced Grid Support in Single- and Multi-Inverter Islands

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Andy

    2016-08-16

    As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1. In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2. The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness.

  15. Efficient/reliable dc-to-dc inverter circuit

    Science.gov (United States)

    Pasciutti, E. R.

    1970-01-01

    Feedback loop, which contains an inductor in series with a saturable reactor, is added to a standard inverter circuit to permit the inverter power transistors to be switched in a controlled and efficient manner. This inverter is applicable where the power source has either high or low impedance properties.

  16. Do pregnant women know how to correct inverted nipples ...

    African Journals Online (AJOL)

    Inverted nipples occur in an estimated 9 to 10 percent of women globally, contributing to the number of women who are not exclusively breastfeeding their infants. Women with inverted nipples may want to breastfeed, but infants may be unable to latch to the breast. Inverted nipples can be corrected, but it is unclear if women ...

  17. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng

    2007-01-01

    This paper presents the careful integration of a newly proposed Z-source topological concept to the basic neutral-point-clamped (NPC) inverter topology for designing a three-level inverter with both voltage-buck and voltage-boost capabilities. The designed Z-source NPC inverter uses two unique X-...

  18. Mobile Inverted Constructivism: Education of Interaction Technology in Social Media

    Science.gov (United States)

    Chai, Jia-Xiang; Fan, Kuo-Kuang

    2016-01-01

    The combination of social media and invert teaching is a new path to inverting interation technology education and reconstructing the curriculum of context. In this paper, based on the theory of constructivism learning, a model named Mobile Inverted Constructivism (MIC) is provided. Moreover, in view of the functional quality of social media in…

  19. Power Inverter Topologies for Photovoltaic Modules - A Review

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Pedersen, John Kim; Blaabjerg, Frede

    2002-01-01

    This review-paper focuses on the latest development of inverters for photovoltaic AC-Modules. The power range for these inverters is usually within 90 Watt to 500 Watt, which covers the most commercial photovoltaic-modules. Self-commutated inverters have replaced the grid-commutated ones. The same...

  20. Diode-Assisted Buck-Boost Current Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Cai, Liang; Loh, P.C.

    2007-01-01

    This paper presents a couple of novel current source inverters (CSIs) with the enhanced current buckboost capability. With the unique diode-inductor network added between current source inverter circuitry and current boost elements, the proposed buck-boost current source inverters demonstrate...

  1. A single phase photovoltaic inverter control for grid connected system

    Indian Academy of Sciences (India)

    during light load condition the excess energy generated from the PV inverter is fed to the grid and; during an overload condition or in case of unfavorable atmospheric conditions the load demand is met by both PV inverter and the grid. In order to synchronize the PV inverter with the grid a dual transport delay based phase ...

  2. Online Variable Topology-Type Photovoltaic Grid-Connected Inverter

    DEFF Research Database (Denmark)

    Wu, Fengjiang; Sun, Bo; Duan, Jiandong

    2015-01-01

    and H-bridge inverter under the conditions of variable output voltage and power of the PV array. It is proved that, compared with the H-bridge inverter, the operation range of the cascaded inverter is wider, whereas the total loss is larger. Furthermore, a novel online variable topology-type grid...

  3. DC-to-AC inverter ratio failure detector

    Science.gov (United States)

    Ebersole, T. J.; Andrews, R. E.

    1975-01-01

    Failure detection technique is based upon input-output ratios, which is independent of inverter loading. Since inverter has fixed relationship between V-in/V-out and I-in/I-out, failure detection criteria are based on this ratio, which is simply inverter transformer turns ratio, K, equal to primary turns divided by secondary turns.

  4. Stochastic p-Bits for Invertible Logic

    Directory of Open Access Journals (Sweden)

    Kerem Yunus Camsari

    2017-07-01

    Full Text Available Conventional semiconductor-based logic and nanomagnet-based memory devices are built out of stable, deterministic units such as standard metal-oxide semiconductor transistors, or nanomagnets with energy barriers in excess of ≈40–60  kT. In this paper, we show that unstable, stochastic units, which we call “p-bits,” can be interconnected to create robust correlations that implement precise Boolean functions with impressive accuracy, comparable to standard digital circuits. At the same time, they are invertible, a unique property that is absent in standard digital circuits. When operated in the direct mode, the input is clamped, and the network provides the correct output. In the inverted mode, the output is clamped, and the network fluctuates among all possible inputs that are consistent with that output. First, we present a detailed implementation of an invertible gate to bring out the key role of a single three-terminal transistorlike building block to enable the construction of correlated p-bit networks. The results for this specific, CMOS-assisted nanomagnet-based hardware implementation agree well with those from a universal model for p-bits, showing that p-bits need not be magnet based: any three-terminal tunable random bit generator should be suitable. We present a general algorithm for designing a Boltzmann machine (BM with a symmetric connection matrix [J] (J_{ij}=J_{ji} that implements a given truth table with p-bits. The [J] matrices are relatively sparse with a few unique weights for convenient hardware implementation. We then show how BM full adders can be interconnected in a partially directed manner (J_{ij}≠J_{ji} to implement large logic operations such as 32-bit binary addition. Hundreds of stochastic p-bits get precisely correlated such that the correct answer out of 2^{33} (≈8×10^{9} possibilities can be extracted by looking at the statistical mode or majority vote of a number of time samples. With perfect

  5. Stochastic p -Bits for Invertible Logic

    Science.gov (United States)

    Camsari, Kerem Yunus; Faria, Rafatul; Sutton, Brian M.; Datta, Supriyo

    2017-07-01

    Conventional semiconductor-based logic and nanomagnet-based memory devices are built out of stable, deterministic units such as standard metal-oxide semiconductor transistors, or nanomagnets with energy barriers in excess of ≈40 - 60 kT . In this paper, we show that unstable, stochastic units, which we call "p -bits," can be interconnected to create robust correlations that implement precise Boolean functions with impressive accuracy, comparable to standard digital circuits. At the same time, they are invertible, a unique property that is absent in standard digital circuits. When operated in the direct mode, the input is clamped, and the network provides the correct output. In the inverted mode, the output is clamped, and the network fluctuates among all possible inputs that are consistent with that output. First, we present a detailed implementation of an invertible gate to bring out the key role of a single three-terminal transistorlike building block to enable the construction of correlated p -bit networks. The results for this specific, CMOS-assisted nanomagnet-based hardware implementation agree well with those from a universal model for p -bits, showing that p -bits need not be magnet based: any three-terminal tunable random bit generator should be suitable. We present a general algorithm for designing a Boltzmann machine (BM) with a symmetric connection matrix [J ] (Ji j=Jj i) that implements a given truth table with p -bits. The [J ] matrices are relatively sparse with a few unique weights for convenient hardware implementation. We then show how BM full adders can be interconnected in a partially directed manner (Ji j≠Jj i) to implement large logic operations such as 32-bit binary addition. Hundreds of stochastic p -bits get precisely correlated such that the correct answer out of 233 (≈8 ×1 09) possibilities can be extracted by looking at the statistical mode or majority vote of a number of time samples. With perfect directivity (Jj i=0 ) a small

  6. Topology of the germ plasm and development of primordial germ cells in inverted amphibian eggs

    Science.gov (United States)

    Wakahara, M.; Neff, A. W.; Malacinski, G. M.

    1984-01-01

    Inverted Xenopus eggs have reduced numbers of primordial germ cells (PGCs). The extent of the reduction varies from spawning to spawning. Histologic examination revealed that PGC counts were lowest in inverted eggs which displayed the greatest amount of shift in the vegetal mass of large yolk platelets, although the germ plasm itself always remained localized in the egg's original vegetal hemisphere. Even at blastulation the germ plasm continued to be localized in the egg's original vegetal hemisphere. In many cases, however, it was confined to the periphery of the embryo, which probably accounts for the reduced PGC number in some tadpoles. In other cases it may have been dispersed and therefore not detectable in histologic analyses. Although the altered site of involution in inverted embryos did not influence PGC development, subsequent cell movement patterns apparently did. Those embryos which displayed the largest degree of pattern reversal at the tail-bud stage also exhibited the most extreme reduction in PGC numbers. A brief cold shock (4 degrees C, 10 min) prior to first cleavage leads to a further reduction in PGC numbers in inverted embryos, probably as a result of the displacement of the germ plasm away from its original vegetal pole location.

  7. Transistor Clamped Five-Level Inverter using Non-Inverting Double Reference Single Carrier PWM Technique for photovoltaic applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Fedák, Viliam

    2017-01-01

    supplies or capacitor banks. To design the proposed five level inverter five numbers of power control switches and eight diodes are required. The proposed inverter circuitry is investigated by using Non-Inverting Double Reference Single Carrier PWM (NIDRSC PWM) Technique in terms of harmonics content...

  8. A Transformer-less Single Phase Inverter For photovoltaic Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Alizadeh, Ebrahim; Qu, Ying

    2017-01-01

    A single phase transformer-less inverter is introduced in this paper. The negative polarities of the input voltage and output terminal have common ground. Therefore, the leakage current problem that is common in PV systems is eliminated naturally. In addition, the proposed inverter has fewer...... components compared with its counterparts and only one switch conducts during the active states which enhance the inverter efficiency. The proposed inverter is analyzed in details and compared with some existing topologies. The performance of the proposed inverter is validated using the simulation results....

  9. Initial clinical presentation of Takotsubo cardiomyopathy with-a focus on electrocardiographic changes: A literature review of cases.

    Science.gov (United States)

    Sanchez-Jimenez, Erick Francisco

    2013-07-26

    To review the initial presentation and demonstrate the importance of Takotsubo cardiomyopathy. A PubMed search using the terms "Takotsubo cardiomyopathy (TC)" and "apical ballooning syndrome" yielded 211 publications. Only those that were relevant were fully reviewed. The gender, age, precipitating stressor, main complaint at presentation, electrocardiogram (ECG) at admission and serum cardiac markers of patients diagnosed with TC, were extracted as available. The data were organized in tables and graphics, and the incidence of the disorder was calculated and analyzed. A total of 250 clinical cases were examined. The predominant gender that was affected was female, with a prevalence of 87.5%. The mean age of presentation was 64 ± 14 years. The cases were divided by age into 10-year intervals. The age interval of 60-69 years showed the highest frequency of TC, accounting for 79 cases. The most common precipitating stressor was physical (50% of cases). Chest pain was the primary complaint at presentation (58.8% of cases) followed by dyspnea (30% of cases). The ST segment changes category was the most common (60%), followed by T wave changes (39.6%). Of the 60% of cases with ST segment changes, 12% had concomitant T wave changes. This means that for 27.6% of the cases, the primary abnormality in the ECG was T wave changes; 87.6% of cases with TC had a change in the ST segment, in the T wave or in both. The percentage of ECGs presenting with changes in the anterior wall was 54.4% (35.6% of ST segment elevation + 1.6% of ST segment depression + 17.2% of T wave inversion). The percentage of patients presenting with changes in the lateral segment of the heart was 46.8%, while the percentage of patients with changes in the inferior heart was 21.6% and the percentage of patients with changes in the apical region was only 16%. The prevalence of elevated creatinine kinase and/or troponin on initial presentation was 89.3%. It is essential that every physician consider

  10. Advanced Control of Wheeled Inverted Pendulum Systems

    CERN Document Server

    Li, Zhijun; Fan, Liping

    2013-01-01

    Advanced Control of Wheeled Inverted Pendulum Systems is an orderly presentation of recent ideas for overcoming the complications inherent in the control of wheeled inverted pendulum (WIP) systems, in the presence of uncertain dynamics, nonholonomic kinematic constraints as well as underactuated configurations. The text leads the reader in a theoretical exploration of problems in kinematics,dynamics modeling, advanced control design techniques,and trajectory generation for WIPs. An important concern is how to deal with various uncertainties associated with the nominal model, WIPs being characterized by unstable balance and unmodelled dynamics and being subject to time-varying external disturbances for which accurate models are hard to come by.   The book is self-contained, supplying the reader with everything from mathematical preliminaries and the basic Lagrange-Euler-based derivation of dynamics equations to various advanced motion control and force control approaches as well as trajectory generation met...

  11. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  12. Design of High Efficient MPPT Solar Inverter

    Directory of Open Access Journals (Sweden)

    Sunitha K. A.

    2017-01-01

    Full Text Available This work aims to design a High Efficient Maximum Power Point Tracking (MPPT Solar Inverter. A boost converter is designed in the system to boost the power from the photovoltaic panel. By this experimental setup a room consisting of 500 Watts load (eight fluorescent tubes is completely controlled. It is aimed to decrease the maintenance cost. A microcontroller is introduced for tracking the P&O (Perturb and Observe algorithm used for tracking the maximum power point. The duty cycle for the operation of the boost convertor is optimally adjusted by using MPPT controller. There is a MPPT charge controller to charge the battery as well as fed to inverter which runs the load. Both the P&O scheme with the fixed variation for the reference current and the intelligent MPPT algorithm were able to identify the global Maximum power point, however the performance of the MPPT algorithm was better.

  13. Design And Implementation Of Cost Effective Inverter

    Directory of Open Access Journals (Sweden)

    Niaz Morshedul Haque

    2017-10-01

    Full Text Available This paper deals with the design and construct of a 100 Watt 220 Volt and 50 Hz Inverter. The system is designed without any microcontroller and it has a cost-effective design architecture. The elementary purpose of this device is to transmute 12 V DC to 220 V AC. Snubber technology is used to diminish the reverse potential transients and excessive heat of transformer winding and transistor switches. Switching pulse generated by NE 555 timer circuit and comparator circuit was used to take signal strength input from its rear as well as from both sides for triggering the MOSFET switches. Another switch is used to invert pulse between two switching circuitries. A 5 volts regulator IC 7805 was used to supply fixed 5V for biasing the switching and amplifying circuitry.

  14. Electronic Document Management Using Inverted Files System

    Directory of Open Access Journals (Sweden)

    Suhartono Derwin

    2014-03-01

    Full Text Available The amount of documents increases so fast. Those documents exist not only in a paper based but also in an electronic based. It can be seen from the data sample taken by the SpringerLink publisher in 2010, which showed an increase in the number of digital document collections from 2003 to mid of 2010. Then, how to manage them well becomes an important need. This paper describes a new method in managing documents called as inverted files system. Related with the electronic based document, the inverted files system will closely used in term of its usage to document so that it can be searched over the Internet using the Search Engine. It can improve document search mechanism and document save mechanism.

  15. Electron Cloud with Inverted Beam Screens

    CERN Document Server

    Maury Cuna, H

    2011-01-01

    We report the results of computer simulations studying the effect of wrongly oriented LHC beam screens on the local electron-cloud heat load and density. At 3.5 or 7-TeV energy and for maximum secondary emission-yield values below 1.5, with the inverted sawtooth orientation about ten times higher heat load is expected than for the standard orientation, and the wrongly oriented sawtooth chambers could lead to a local heat-load bottleneck during the process of surface conditioning at 25-ns bunch spacing. The available cooling margin can be significantly increased by correcting the sawtooth orientations at least for two dipole magnets in LHC arc cells 26 and 32 R3, in order that there be no half-cell cooling loop containing more than one inverted screen.

  16. Electron Cloud with Inverted Beam Screens

    CERN Document Server

    Maury Cuna, H; CERN. Geneva. ATS Department

    2011-01-01

    We report the results of computer simulations studying the effect of wrongly oriented LHC beam screens on the local electron-cloud heat load and density. At 3.5 or 7-TeV energy and for maximum secondary emission-yield values below 1.5, with the inverted sawtooth orientation about ten times higher heat load is expected than for the standard orientation, and the wrongly oriented sawtooth chambers could lead to a local heatload bottleneck during the process of surface conditioning at 25-ns bunch spacing. The available cooling margin can be significantly increased by correcting the sawtooth orientations at least for two dipole magnets in LHC arc cells 26 and 32 R3, in order that there be no half-cell cooling loop containing more than one inverted screen.

  17. Stability Analysis Method of Parallel Inverter

    OpenAIRE

    Li, Jun; Chen, Jie; Xue, Yaru; Qiu, Ruichang; Liu, Zhigang

    2017-01-01

    In order to further provide theoretical support for the stability of an auxiliary inverter parallel system, a new model which covers most of control parameters needs to be established. However, the ability of the small-signal model established by the traditional method is extremely limited, so this paper proposes a new small-signal modeling method for the parallel system. The new small-signal model not only can analyze the influence of the droop parameters on the system performance, but also ...

  18. FET commutated current-FED inverter

    Science.gov (United States)

    Rippel, Wally E. (Inventor); Edwards, Dean B. (Inventor)

    1983-01-01

    A shunt switch comprised of a field-effect transistor (Q.sub.1) is employed to commutate a current-fed inverter (10) using thyristors (SCR1, SCR2) or bijunction transistors (Q.sub.2, Q.sub.3) in a full bridge (1, 2, 3, 4) or half bridge (5, 6) and transformer (T.sub.1) configuration. In the case of thyristors, a tapped inverter (12) is employed to couple the inverter to a dc source to back bias the thyristors during commutation. Alternatively, a commutation power supply (20) may be employed for that purpse. Diodes (D.sub.1, D.sub.2) in series with some voltage dropping element (resistor R.sub.12 or resistors R.sub.1, R.sub.2 or Zener diodes D.sub.4, D.sub.5) are connected in parallel with the thyristors in the half bridge and transformer configuration to assure sharing the back bias voltage. A clamp circuit comprised of a winding (18) negatively coupled to the inductor and a diode (D.sub.3) return stored energy from the inductor to the power supply for efficient operation with buck or boost mode.

  19. Stability Analysis Method of Parallel Inverter

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-01-01

    Full Text Available In order to further provide theoretical support for the stability of an auxiliary inverter parallel system, a new model which covers most of control parameters needs to be established. However, the ability of the small-signal model established by the traditional method is extremely limited, so this paper proposes a new small-signal modeling method for the parallel system. The new small-signal model not only can analyze the influence of the droop parameters on the system performance, but also can analyze the influence of the output impedance of the inverter, the unbalanced and nonlinear loads, and the power calculation method and cut-off frequency of the low-pass filter on the system performance and stability. Based on this method, this paper carries out a comprehensive analysis on the performance of a parallel inverter system. And the correctness of the modeling method and analysis process of the system performance and stability are verified by the consistency of the simulation and experimental results.

  20. Síndrome do coração partido (Síndrome de Takotsubo induzida por ecocardiograma de estresse com dobutamina Síndrome del corazón roto (síndrome de Tako-Tsubo inducido por ecocardiograma de esfuerzo con dobutamina Dobutamine stress echocardiography-induced broken heart syndrome (Takotsubo Syndrome

    Directory of Open Access Journals (Sweden)

    Francisco Juarez Cruz de Vasconcelos Filho

    2009-07-01

    Full Text Available Relatamos um caso de síndrome de Takotsubo induzida por ecocardiograma de estresse com dobutamina em uma paciente de 76 anos, hipertensa com queixas clínicas de dor precordial, em consulta cardiológica eletiva. Para exclusão de dor torácica de etiologia coronariana foi solicitado ecocardiograma de estresse com dobutamina. O exame foi realizado e, no pico do esforço máximo, o ecocardiograma mostrou acinesia apical com o eletrocardiograma mostrando supradesnivelamento do segmento ST em D1, AVL e V2. A paciente foi internada e submetida a coronariografia, que mostrou coronárias normais e VE com balonamento apical. A paciente evoluiu estável com reversão do quadro 21 dias após o quadro inicial.Relatamos un caso de síndrome de Tako-Tsubo inducido por ecocardiograma de esfuerzo con dobutamina en una paciente de 76 años, hipertensa con quejas clínicas de dolor precordial, en consulta cardiológica electiva. Para exclusión de dolor torácico de etiología coronaria se solicitó ecocardiograma de esfuerzo con dobutamina. El examen fue realizado, y en el pico de esfuerzo máximo, el ecocardiograma mostró acinesia apical con el electrocardiograma mostrando supradesnivel del segmento ST en D1, AVL y V2. La paciente fue internada y sometida a coronariografía, que mostró coronarias normales y VI con abombamiento apical. La paciente evolucionó estable con reversión del cuadro 21 días después del cuadro inicial.We report a case of dobutamine stress echocardiography-induced Takotsubo syndrome in a 76-year-old hypertensive patient with clinical complaints of chest pain in an elective visit to the cardiologist. Dobutamine-stress-echocardiography was requested to rule out chest pain of coronary origin. During the test, at peak exercise, echocardiogram showed apical akinesia and electrocardiogram showed ST-segment elevation in D1, AVL, and V2. The patient was hospitalized and underwent coronary angiography, which showed normal coronary arteries

  1. To tilfælde af takotsubo-kardiomyopati hos patienter behandlet med høje doser inhalerede beta-2-agonister

    DEFF Research Database (Denmark)

    Thomsen, Camilla Fjord; Jeppesen, Jørgen Lykke; Stride, Nis Ottesen

    2016-01-01

    Takotsubo cardiomyopathy (TCM) is characterised by reversible left ventricular dysfunction in patients presenting with acute coronary syndrome (ACS). TCM is considered multifactorial, and the repetitive exposure to inhaled beta-2-agonists has been suspected to induce TCM in predisposed individuals....... We report two cases of TCM in female patients presenting with ACS both exposed to inhaled beta-2-agonists. Eccocardiography revealed apical ballooning and reduced left ventricular function. Coronary angiography was with no significant stenosis. Both patients recovered by anticongestive treatment....

  2. “Reverse McConnell’s Sign”: Interpreting Interventricular Hemodynamic Dependency and Guiding the Management of Acute Heart Failure during Takotsubo Cardiomyopathy

    OpenAIRE

    Kan Liu; Zhongxia Sun; Tiemin Wei

    2015-01-01

    Although most patients with Takotsubo cardiomyopathy (TTC) have benign clinical course and prognosis, TTC can induce acute heart failure and hemodynamic instability. TTC mimics the clinical features of acute anterior wall myocardial infarction (AMI). Bedside clinicians often have a diagnostic dilemma when cardiac catheterization and angiography are either contraindicated or can cause potential adverse consequences. Misdiagnosing TTC as AMI will lead to initiation of harmful pharmacological or...

  3. Comparing the aerodynamic forces produced by dragonfly forewings during inverted and non-inverted flight

    Science.gov (United States)

    Shumway, Nathan; Gabryszuk, Mateusz; Laurence, Stuart

    2017-11-01

    Experiments were conducted with live dragonflies to determine their wing kinematics during free flight. The motion of one forewing in two different tests, one where the dragonfly is inverted, is described using piecewise functions and simulated using the OVERTURNS Reynolds-averaged Navier-Stokes solver that has been used in previous work to determine trim conditions for a fruit fly model. For the inverted dragonfly the upstrokes were significantly longer than the downstrokes, pitching amplitude is lower than that for the right-side up flight and the flap amplitude is larger. Simulations of dragonfly kinematics of a single forewing are presented to determine how the forces differ for a dragonfly flying inverted and a dragonfly flying right-side up. This work was supported by the United States Army Research Laboratory's Micro Autonomous Systems and Technology Collaborative Technology Alliance Project MCE-16-17 1.2.

  4. Dynamics of electrocardiographic changes, brain-natriuretic peptide and cortisol levels in a patient with stress (takotsubo cardiomyopathy: A case report

    Directory of Open Access Journals (Sweden)

    Đurić Ivica

    2013-01-01

    Full Text Available Introduction. Takotsubo cardiomyopathy is a transient acute heart failure syndrome caused by stress that provokes left ventricular mid-apical akinesis and mimics acute coronary syndrome. Case report. A 66-year-old woman had chest pain and dispnoea a few hours before hospitalization. A sudden emotional stressful event preceded the symptoms. Electrocardiographic abnormalities - precordial ST elevation and modest increase of cardiac troponin mimiced acute myocardial infarction. However, echocardiographic examination showed apical ballooning with markedly diminished left ventricle ejection fraction and the obstruction in the outflow tract of the left ventricle. Coronary angiography at admission showed no coronary stenosis and slower blood flow through the left anterior descending artery. According to anamnesis, echocardiography and coronarography finding we established the diagnosis of stress cardiomyopathy - takotsubo cardiomyopathy. We described in details the slow but dynamic electrocardiographic changes, levels of brain natriuretic peptide, cortisol and echocardiography evolution of disease during a 4-month follow-up till the full recovery. Conclusion. Stress (takotsubo cardiomyopathy - became an important differential diagnosis of acute anterior myocardial infarction and it should be reconsidered every time when emotionally stressed patients with transient-apical akinesis or dyskinesis of the LV are present.

  5. Síndrome de Tako-Tsubo em decorrência de bloqueio neuromuscular residual: relato de caso Síndrome de Tako-Tsubo como consecuencia de bloqueo neuromuscular residual: relato de caso Tako-Tsubo syndrome secondary to residual neuromuscular blockade: case report

    Directory of Open Access Journals (Sweden)

    Marcos Guilherme Cunha Cruvinel

    2008-12-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A síndrome de Tako-Tsubo é uma complicação pós-operatória rara, com mortalidade em torno de 5%. O objetivo deste relato é apresentar o bloqueio neuromuscular residual como fator desencadeante da referida síndrome, discutir sobre a mesma e alertar sobre o bloqueio neuromuscular residual. RELATO DO CASO: Paciente do sexo feminino, 61 anos, estado físico ASA I, submetida à anestesia geral associada a bloqueio paravertebral cervical para reparo artroscópico de lesão de manguito rotator. Após extubação foi evidenciado bloqueio neuromuscular residual por meio do exame clínico. Na sala de recuperação pós-anestésica evoluiu com sonolência, taquicardia, hipertensão arterial e acidose respiratória grave. Após a reintubação, evoluiu com parada cardíaca em atividade elétrica sem pulso, revertida com adrenalina e massagem cardíaca externa. Apresentou no pós-operatório elevação de segmento ST, aumento de troponina e acinesia de segmento médio-apical de ventrículo esquerdo com fração de ejeção estimada em 30%. A cineangiocoronariografia mostrou coronárias isentas de ateromatose significativa e grave comprometimento da função sistólica com acinesia inferior e ântero-septo-apical com hipercontratilidade compensatória de suas porções basais. Com o tratamento instituído houve recuperação funcional completa. CONCLUSÕES: O bloqueio neuromuscular residual associado à paralisia diafragmática e possível atelectasia pulmonar levando a insuficiência respiratória, hipercapnia e descarga adrenérgica foram os fatores desencadeantes da síndrome de Tako-Tsubo com sua grave repercussão clínica.JUSTIFICATIVA Y OBJETIVOS: El Síndrome de Tako-Tsubo es una complicación postoperatoria rara con una mortalidad en torno de un 5%. El objetivo de este relato es presentar el bloqueo neuromuscular residual como factor desencadenante del referido síndrome, discutir sobre él y alertar sobre el bloqueo

  6. Design of inverters for the PHOTONERGY project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-08-01

    The PHOTONERGY project (the former SolcelleInverter project) was initiated on the 1st of September 2001, with a state-of-the-art analysis, which concluded into specifications. Based on this 23 topologies were analyzed in for efficiencies. The results from this analysis was five candidates which all showed a somewhat good efficiency. These five topologies were in further investigated by means of an initial design-iteration and simulations. Two different solutions were picked up in due to their high efficiency and low cost. 1. The standard full-bridge phase shifted DC/DC converter together with a standard DC/AC inverter, 2. A modified version of the novel Shimizu topology. A patent is pending on this modified version. These two inverters are in this document developed and made ready for prototyping. This includes design and selection of reactive- and switching-components, e.g. filter- and bulk-capacitors, low- and high-frequency inductors, high frequency transformers, MOSFETs and diodes. The design of auxiliary circuits is also included, e.g. gate drivers for the MOSFETs, measuring circuits for the grid-current and -voltage, PV-module-current and voltage, protection circuits, hardware near controllers and finally a switch mode power supply. However, the design of the various controllers, except the hardware near PV-current controller for the full bridge phase shifted converter, is not documented in this report but will come later on. This includes all controllers, e.g. maximum power point tracking for the PV-module, utility grid current controller, DC-link voltage controller, phase locked loops, and detection of islanding operation. All of these control loops are to be implemented in a micro-controller. (au)

  7. Multilayer control for inverters in parallel operation without signal interconnection

    DEFF Research Database (Denmark)

    Hua, Ming; Hu, Haibing; Xing, Yan

    2011-01-01

    A multilayer control is proposed for inverters with wireless parallel operation in this paper. The control is embedded in every inverter respectively and consists of three layers. The first layer is based on an improved droop method, which shares the active and reactive power in each module...... by adjusting the phase and amplitude of the output voltage respectively. The second layer is to compensate the droop voltage caused by the droop control and thus improve the load regulation performance of the inverter. The third layer limits the phase deviation between the inverter and the shared ac bus...... in order to ensure all the paralleled inverters keeping in phase. The operational principle and implementation are analyzed in details. A prototype, configured by two paralleled inverters, is set up. Experimental results verify the validity of the proposed control....

  8. The mirror map for invertible LG models

    OpenAIRE

    Kreuzer, M

    1994-01-01

    Calculating the (a,c) ring of the maximal phase orbifold for `invertible' Landau--Ginzburg models, we show that the Berglund--H"ubsch construction works for all potentials of the relevant type. The map that sends a monomial in the original model to a twisted state in the orbifold representation of the mirror is constructed explicitly. Via this map, the OP selection rules of the chiral ring exactly correspond to the twist selection rules for the orbifold. This shows that we indeed arrive at th...

  9. On the invertibility of elementary operators

    OpenAIRE

    Boudi, Nadia; Bračič, Janko

    2013-01-01

    Let $\\mathscr{X}$ be a complex Banach space and $\\mathcal{L}(\\mathscr{X})$ be the algebra of all bounded linear operators on $\\mathscr{X}$. For a given elementary operator $\\Phi$ of length $2$ on $\\mathcal{L}(\\mathscr{X})$, we determine necessary and sufficient conditions for the existence of a solution of the equation ${\\rm X} \\Phi=0$ in the algebra of all elementary operators on $\\mathcal{L}(\\mathscr{X})$. Our approach allows us to characterize some invertible elementary operators of length...

  10. Magnetically Coupled Impedance-Source Inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    input-to-output gain and the presence of an impedance network. The former means a high dc-link voltage, which can stress the semiconductor switches unnecessarily. The latter leads to increases in cost and size, which similarly are undesirable. To lessen these concerns, an interesting approach is to use...... magnetically coupled transformers or inductors to raise the gain and modulation ratio simultaneously, while reducing the number of passive components needed. A study of the approach is now presented to show how various existing magnetically coupled inverters can be derived by applying a generic methodology...

  11. Using Inverted Indices for Accelerating LINGO Calculations

    DEFF Research Database (Denmark)

    Kristensen, Thomas Greve; Nielsen, Jesper; Pedersen, Christian Nørgaard Storm

    2011-01-01

    queries. The previous best method for rapidly calculating the LINGOsim similarity matrix required specialised hardware to yield a significant speedup over existing methods. By representing LINGO multisets in the verbose representation and using inverted indices it is possible to calculate LINGOsim......The ever growing size of chemical data bases calls for the development of novel methods for representing and comparing molecules. One such method called LINGO is based on fragmenting the SMILES string representation of molecules. Comparison of molecules can then be performed by calculating...

  12. Nonlinear Feedback Control of the Rotary Inverted Pendulum

    Science.gov (United States)

    2017-06-01

    pendulum include wheeled mobile robots, which can be useful for personal mobility . C. PRIOR WORK There are nonlinear control techniques that have...results. Among the applications of the inverted pendulum is a two wheeled robot. One mobile inverted pendulum robot was created by Grasser, D’Arrigo... pendulum which could shift the weight of the load to keep the pendulum straight up when on a slope [10]. The work in mobile inverted pendulums can

  13. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  14. Integral inverter/battery charger for use in electric vehicles

    Science.gov (United States)

    Thimmesch, D.

    1983-01-01

    The design and test results of a thyristor based inverter/charger are discussed. A battery charger is included integral to the inverter by using a subset of the inverter power circuit components. The resulting charger provides electrical isolation between the vehicle propulsion battery and ac line and is capable of charging a 25 kWh propulsion battery in 8 hours from a 220 volt ac line. The integral charger employs the inverter commutation components at a resonant ac/dc isolated converter rated at 3.6 kW. Charger efficiency and power factor at an output power of 3.6 kW are 86% and 95% respectively. The inverter, when operated with a matching polyphase ac induction motor and nominal 132 volt propulsion battery, can provide a peak shaft power of 34 kW (45 ph) during motoring operation and 45 kW (60 hp) during regeneration. Thyristors are employed for the inverter power switching devices and are arranged in an input-commutated topology. This configuration requires only two thyristors to commutate the six main inverter thyristors. Inverter efficiency during motoring operation at motor shaft speeds above 450 rad/sec (4300 rpm) is 92-94% for output power levels above 11 KW (15 hp). The combined ac inverter/charger package weighs 47 kg (103 lbs).

  15. A new Zero Voltage Switching three-level NPC inverter

    DEFF Research Database (Denmark)

    He, Ning; Chen, Yenan; Xu, Dehong

    2015-01-01

    A novel Zero Voltage Switching (ZVS) three-level NPC inverter topology using a new ZVS Space Vector Modulation (SVM) scheme is proposed. A detailed operation analysis of ZVS three-level NPC inverter is given. The ZVS condition of the proposed ZVS inverter is derived and it can be achieved of all...... switches in the proposed inverter, which include both the main switches and the auxiliary switches. The design of resonant circuits parameters is also provided. Finally the proposed circuit and ZVS SVM scheme are verified by experimental results and demonstrate a superior performance....

  16. Advanced DC/AC inverters applications in renewable energy

    CERN Document Server

    Luo, Fang Lin

    2013-01-01

    DC/AC inversion technology is of vital importance for industrial applications, including electrical vehicles and renewable energy systems, which require a large number of inverters. In recent years, inversion technology has developed rapidly, with new topologies improving the power factor and increasing power efficiency. Proposing many novel approaches, Advanced DC/AC Inverters: Applications in Renewable Energy describes advanced DC/AC inverters that can be used for renewable energy systems. The book introduces more than 100 topologies of advanced inverters originally developed by the authors,

  17. Optimized Pulse Width Modulation for transformerless active-NPC inverters

    DEFF Research Database (Denmark)

    Achilladelis, Nikolaos; Koutroulis, Eftichios; Blaabjerg, Frede

    2014-01-01

    The transformerless DC/AC inverter topologies are employed in Photovoltaic systems in order to improve the power conversion efficiency, power density and cost. The Active-Neutral Point Clamped (Active-NPC) transformerless inverters have the advantage of achieving better thermal balance among...... their power semiconductors. In this paper, a new modulation technique is proposed for optimally controlling the power switches employed in transformerless Active-NPC inverters. The design results demonstrate that compared to the existing PWM strategies, using the proposed method results in lower total power...... losses and significantly better distribution of the power losses among the semiconductors of the Active-NPC inverter....

  18. Inverted face processing in body dysmorphic disorder.

    Science.gov (United States)

    Feusner, Jamie D; Moller, Hayley; Altstein, Lily; Sugar, Catherine; Bookheimer, Susan; Yoon, Joanne; Hembacher, Emily

    2010-11-01

    Individuals with body dysmorphic disorder (BDD) are preoccupied with perceived defects in appearance. Preliminary evidence suggests abnormalities in global and local visual information processing. The objective of this study was to compare global and local processing in BDD subjects and healthy controls by testing the face inversion effect, in which inverted (upside-down) faces are recognized more slowly and less accurately relative to upright faces. Eighteen medication-free subjects with BDD and 17 matched, healthy controls performed a recognition task with sets of upright and inverted faces on a computer screen that were either presented for short duration (500 ms) or long duration (5000 ms). Response time and accuracy rates were analyzed using linear and logistic mixed effects models, respectively. Results indicated that the inversion effect for response time was smaller in BDD subjects than controls during the long duration stimuli, but was not significantly different during the short duration stimuli. Inversion effect on accuracy rates did not differ significantly between groups during either of the two durations. Lesser inversion effect in BDD subjects may be due to greater detail-oriented and piecemeal processing for long duration stimuli. Similar results between groups for short duration stimuli suggest that they may be normally engaging configural and holistic processing for brief presentations. Abnormal visual information processing in BDD may contribute to distorted perception of appearance; this may not be limited to their own faces, but to others' faces as well. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. INVERTING ORTHOTOPIC ILEOCYSTOPLASTY FOR SHORT MESENTERY

    Directory of Open Access Journals (Sweden)

    V. A. Perepechay

    2010-01-01

    Full Text Available During orthotopic ileocystoplasty, the short mesentery causes an increase in the risk of incompetence of anastomosis of the reservoir with the urethra. Inverting orthotopic ileocystoplasty ensures a free reservoir pull-through into the small pelvis and eliminates tissue tension in the anastomosis. The proposed procedure differs from the Studer operation in that the reservoir is sutured lengthwise, after which it is inverted between the mesenteric leaves. The posterior reservoir wall is anteverted and freely brought out into the small pelvis. This reduces the distance to the urethral stump by 3-4 cm. This procedure was used in 19 patients to be operated on. There were no cases of reservoir or reservoir-urethral anastomotic incompetence. The mean neocystic capacity was 110, 350, and 490 ml 0, 3, and 12 months, respectively, after urethral catheter removal. The maximum reservoir pressure does not exceed 40 (mean 30 cm H2O. Daytime urinary retention was 94.7%; nocturnal urinary retention during forced nocturnal miction was 79%. The obtained functional results compare well with those achieved during the similar procedures.

  20. INVERTING ORTHOTOPIC ILEOCYSTOPLASTY FOR SHORT MESENTERY

    Directory of Open Access Journals (Sweden)

    V. A. Perepechay

    2014-07-01

    Full Text Available During orthotopic ileocystoplasty, the short mesentery causes an increase in the risk of incompetence of anastomosis of the reservoir with the urethra. Inverting orthotopic ileocystoplasty ensures a free reservoir pull-through into the small pelvis and eliminates tissue tension in the anastomosis. The proposed procedure differs from the Studer operation in that the reservoir is sutured lengthwise, after which it is inverted between the mesenteric leaves. The posterior reservoir wall is anteverted and freely brought out into the small pelvis. This reduces the distance to the urethral stump by 3-4 cm. This procedure was used in 19 patients to be operated on. There were no cases of reservoir or reservoir-urethral anastomotic incompetence. The mean neocystic capacity was 110, 350, and 490 ml 0, 3, and 12 months, respectively, after urethral catheter removal. The maximum reservoir pressure does not exceed 40 (mean 30 cm H2O. Daytime urinary retention was 94.7%; nocturnal urinary retention during forced nocturnal miction was 79%. The obtained functional results compare well with those achieved during the similar procedures.

  1. Inverting dedevelopment: geometric singularity theory in embryology

    Science.gov (United States)

    Bookstein, Fred L.; Smith, Bradley R.

    2000-10-01

    The diffeomorphism model so useful in the biomathematics of normal morphological variability and disease is inappropriate for applications in embryogenesis, where whole coordinate patches are created out of single points. For this application we need a suitable algebra for the creation of something from nothing in a carefully organized geometry: a formalism for parameterizing discrete nondifferentiabilities of invertible functions on Rk, k $GTR 1. One easy way to begin is via the inverse of the development map - call it the dedevelopment map, the deformation backwards in time. Extrapolated, this map will inevitably have singularities at which its derivative is zero. When the dedevelopment map is inverted to face forward in time, the singularities become appropriately isolated infinities of derivative. We have recently introduced growth visualizations via extrapolations to the isolated singularities at which only one directional derivative is zero. Maps inverse to these create new coordinate patches directionally rather than radically. The most generic singularity that suits this purpose is the crease f(x,y) equals (x,x2y+y3), which has already been applied in morphometrics for the description of focal morphogenetic phenomena. We apply it to embryogenesis in the form of its analytic inverse, and demonstrate its power using a priceless new data set of mouse embryos imaged in 3D by micro-MR with voxels smaller than 100micrometers 3.

  2. Aalborg Inverter - A New Type of “Buck in Buck, Boost in Boost” Grid-Tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Ji, Junhao; Blaabjerg, Frede

    2015-01-01

    This paper presents a new family of high efficiency dc/ac grid-tied inverter with a wide variation of input dc voltage. It is a “boost in boost, buck in buck” inverter, meaning that only one power stage works at high frequency in order to achieve minimum switching loss. The minimum voltage drop...... is larger than the magnitude of the ac voltage, it is a voltage-source inverter, and on the contrary it is current-source inverter in the other mode. A 220 V/50 Hz/ 2000 W prototype has been constructed. Simulations and experiments show that it has a good control and system performance....

  3. Inverted nuclear architecture and its development during differentiation of mouse rod photoreceptor cells: a new model to study nuclear architecture.

    Science.gov (United States)

    Solovei, I; Joffe, B

    2010-09-01

    Interphase nuclei have a conserved architecture: heterochromatin occupies the nuclear periphery, whereas euchromatin resides in the nuclear interior. It has recently been found that rod photoreceptor cells of nocturnal mammals have an inverted architecture, which transforms these nuclei in microlenses and supposedly facilitates a reduction in photon loss in the retina. This unique deviation from the nearly universal pattern throws a new light on the nuclear organization. In the article we discuss the implications of the studies of the inverted nuclei for understanding the role of the spatial organization of the nucleus in nuclear functions.

  4. Takotsubo, discinesia apical transitoria: Presentacion de 4 casos y revisión de la literatura Takotsubo, reversible apical ballooning of the left ventricle: Report of 4 cases

    Directory of Open Access Journals (Sweden)

    Bárbara C. Finn

    2005-10-01

    Full Text Available En 1990 se describió un síndrome caracterizado por discinesia apical transitoria, cambios en el electrocardiograma (ECG, mínima elevación de enzimas cardíacas y arterias coronarias normales. Se presenta con mayor frecuencia en mujeres añosas y es precedido por un evento de estrés, ya sea físico o psíquico. La fisiopatología aún no está aclarada y se proponen diversas teorías. La de mayor peso es la que postula una afección secundaria a la descarga de catecolaminas desencadenada por el estrés, sobre un corazón incapaz de mantener una respuesta inotrópica adecuada. Se presentan cuatro casos de pacientes atendidos en nuestro hospital que se manifestaron con síntomas sugerentes de infarto agudo de miocardio asociados a insuficiencia cardiaca, en el contexto de un episodio estresante. Los síntomas preponderantes fueron dolor precordial opresivo y disnea. En el ECG se evidenciaron tanto supradesnivel del segmento ST, como inversión de la onda T. Todos los pacientes presentaron la imagen ecocardiográfica típica de discinesia apical, y todos tuvieron en la cinecoronariografía coronarias normales. Cabe destacar que tanto el ECG, como el ecocardiograma volvieron a la normalidad a partir de las dos semanas.A syndrome of apical ballooning, with ECG mimicking acute myocardial infarctation, mild or no enzymatic changes, and normal coronary angiogram was described in 1990. It presents mainly in middle aged and elderly women and it is preceded by stress triggering circumstances. Several mechanisms have been proposed although the precise cause remains unclear. The most accepted theory proposes the interaction of catecholamines and an inadequate inotropic response. We report four cases that presented with chest pain and sudden onset of heart failure, all patients had physical or emotional stress as a triggering factor. On ECG, ST segment elevation and inverted T waves were observed in the acute phase. All patients had typical echocardiogram

  5. Sine-wave three phase resonance inverter for operation of ...

    African Journals Online (AJOL)

    naeema

    conventional and simple solution to this requirement are in the following [8]. Using conventional H-bridge inverter beside of a step-up transformer. Using a renewable energy source with sufficiently large output voltage, which may be realized by a string of series connected modules followed by an H-bridge inverter [12], [13].

  6. Human Mobile Inverted Pendulum Transporter - a Mechatronic System Case Study

    DEFF Research Database (Denmark)

    Bech, Michael Møller; Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2011-01-01

    , which nevertheless illustrates the potentials of unifying classical engineering technologies (mechanics, electronics, control systems) with modern high-efficient inverter-fed permanent magnet AC motors and the latest MEMS sensor technology. A full-scale fully operational prototype of a two-wheel mobile...... inverted pendulum has been built based on the presented design....

  7. Modified impedance source inverter for power conditioning system

    Indian Academy of Sciences (India)

    ... generalized discussion and design of impedance network elements are presented. Comparison with the classical impedance source inverter is presented. Using simulation, analytical results are presented that ensure stability. The proposed voltage type inverter has reduced inrush current at startup, less capacitor voltage ...

  8. Multiple-load series resonant inverter for induction cooking ...

    Indian Academy of Sciences (India)

    P Sharath Kumar

    In addition, it can achieve efficient and stable zero voltage switching operation in the whole load range. The proposed control scheme is simulated and experimentally verified with two-load inverter configuration. Keywords. Induction cooking; multiple load; series resonant inverter; ZVS; pulse density modulation control. 1.

  9. Requirements of inverted roofs with a drainage layer

    DEFF Research Database (Denmark)

    Leimer, Hans-Peter; Rode, Carsten; Künzel, Hartwig

    2005-01-01

    This contribution illustrates the application of the standard EN ISO 6946 regarding the heat loss of an inverted roof for different regions of Europe. An addendum to the standard (EN ISO 6946:1996/A1, 2003) introduces a correction to the thermal transmittance of inverted roofs due to rain water f...

  10. Power system services provided by inverter connected distributed energy resources

    DEFF Research Database (Denmark)

    For the last few years there has been a significant increase of DER units in Denmark, of those units more and more are connected to the power system using inverters. These inverter connected units have the potential to support the electrical power system with various power system services. One...

  11. Three-phase inverter for small high speed motors

    Science.gov (United States)

    Mccormick, John A.; Valenzuela, Javier A.

    1991-01-01

    A high-frequency three-phase inverter is being developed to drive a miniature centrifugal compressor which is a key component in a long-life space-borne cryocooler. The inverter is a unique transformer-coupled design, tailored to the low-voltage high-current characteristic of the compressor's induction motor. The design and performance demonstration of a breadboard model of the inverter are described. The cryocooler uses a reverse-Brayton cycle with turbomachines to provide 5 watt of cooling at 70 K. The design target for input power to the compressor motor is 175 watts. Line-to-neutral phase voltage waveforms to be supplied by the inverter have an amplitude of 15 volt-rms at a frequency of 8 kHz. DC power at 28 volt is supplied to the inverter. The breadboard inverter was tested with a preliminary development model of the compressor. It drove the compressor over a range of operating conditions encompassing frequencies of 5 to 9 kHz at powers of 56 to 437 watt. Inverter efficiencies, calculated from experimentally verified loss models, ranged from 89 to 95 percent over the tests. The design target on efficiency is 90 percent. The inverter was demonstrated to supply starting current adequate to overcome the starting friction of the compressor's self-acting gas bearings by a safe margin.

  12. Three Phase Soft Commutation Auxilary Resonant Pole Inverter

    OpenAIRE

    Vaclav Sladecek

    2006-01-01

    This paper covers the circuit modification of the power part of the inverter with auxiliary resonant poles utilising configuration of switches realised with routinely produced IGBT modules. Covered is also the control optimisation which goal is the minimisation of switching of the auxiliary resonant pole. Presented results were gained on a prototype of an inverter laboratory sample.

  13. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.

    2012-01-01

    for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  14. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z...

  15. ZMP Reference Trajectory Generation for Biped Robot with Inverted Pendulum Model by Using Virtual Supporting Point

    Science.gov (United States)

    Suzuki, Tomoyuki; Tsuji, Toshiaki; Shibuya, Maki; Ohnishi, Kouhei

    Motion planning of a biped robot based on ZMP is quite popular in recent years. In this method, ZMP reference trajectory is planned at first so that ZMP stays inside of the support polygon. Then, walking pattern is generated based on the trajectory. Conventional methods based on ZMP reference trajectory did not take the dynamics of bipedal locomotion into account. Therefore, the basis of the motion planning was ambiguous and the biped robot did not get human-like walking. This paper proposes ZMP reference trajectory generation with inverted pendulum model by using VSP (Virtual Supporting Point). With this, smooth ZMP reference trajectory based on the dynamics of the inverted pendulum is generated uniquely according to the desired stride and walking cycle.

  16. Hydrodynamics of adiabatic inverted annular flow: an experimental study. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    De Jarlais, G.; Ishii, M.

    1983-01-01

    For low-quality film boiling in tubes or rod bundles, the flow pattern may consist of a liquid jet-like core surrounded by a vapor annulus, i.e., inverted annular flow. The stability, shape, and break-up mechanisms of this liquid core must be understood in order to model correctly this regime and to develop appropriate interfacial transfer correlations. This paper reports on a study in which inverted annular flow was simulated in an adiabatic system. Turbulent water jets, issuing downward from long-aspect nozzles were enclosed within cocurrent gas annuli. Jet-core diameter and velocity, and gas-annulus diameter, velocity, and species were varied, yielding liquid Reynolds numbers up to 33,000, void fractions from 0.29 to 0.95, and relative velocities from near zero to over 80 m/s. Jet-core break-up lengths and secondarily, core break-up mechanisms, were observed visually, using strobe lighting.

  17. Improving generalized inverted index lock wait times

    Science.gov (United States)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  18. Modifications to Battery chargers and inverters Units

    International Nuclear Information System (INIS)

    Raison, Florent

    2015-01-01

    Over-exceeding the seismic specifications of the nuclear industry has always been the top priority of AEG Power Solutions. Since the Forsmark event, and especially since the Fukushima Daichi accident, utilities have reviewed their specifications. As a consequence, safety related battery chargers and inverters have to withstand higher acceleration levels. Simulation, design and test procedures are key drivers of the battery charger and inverter industry. Forces analysis through simulation is the first step of the product design process. The CAD drawings of our equipment, including the mechanical frame of the cabinet and the internal components, are used for the simulation of vibration. In the frame of 10 Hz, most new specifications show higher values, with higher constraints on our equipment. Our nuclear product range has been adapted to these new requirements. PCBs (Printed Circuit Boards), as key components in charge of the regulation and monitoring of the load, are first separately tested during the design phase, as a specific component. They are subjected to the following tests: Critical load analysis, Thermal imaging, Climatic test, Vibration and shock test. Then the complete equipment will follow a complete test program, including: Type test, EMC test, Seismic test, Aging test. Technology is key in achieving goals in terms of robustness and reliability of battery chargers and inverters. AEG Power Solutions renewed its entire range of products in 2011-2013 and made relevant choices. By updating its complete range of nuclear products, AEG Power Solutions is now offering a new range of solutions to the nuclear industry which minimize the risk of component obsolescence, in case of product replacement on existing nuclear power plants, or of new construction. In order to increase the product reliability and to facilitate the qualification programs of the products, the decision was made to offer 100% analogue technology (Software free). The different regulation and

  19. Motion Analysis Based on Invertible Rapid Transform

    Directory of Open Access Journals (Sweden)

    J. Turan

    1999-06-01

    Full Text Available This paper presents the results of a study on the use of invertible rapid transform (IRT for the motion estimation in a sequence of images. Motion estimation algorithms based on the analysis of the matrix of states (produced in the IRT calculation are described. The new method was used experimentally to estimate crowd and traffic motion from the image data sequences captured at railway stations and at high ways in large cities. The motion vectors may be used to devise a polar plot (showing velocity magnitude and direction for moving objects where the dominant motion tendency can be seen. The experimental results of comparison of the new motion estimation methods with other well known block matching methods (full search, 2D-log, method based on conventional (cross correlation (CC function or phase correlation (PC function for application of crowd motion estimation are also presented.

  20. On Invertible Sampling and Adaptive Security

    DEFF Research Database (Denmark)

    Ishai, Yuval; Kumarasubramanian, Abishek; Orlandi, Claudio

    2011-01-01

    Secure multiparty computation (MPC) is one of the most general and well studied problems in cryptography. We focus on MPC protocols that are required to be secure even when the adversary can adaptively corrupt parties during the protocol, and under the assumption that honest parties cannot reliably...... erase their secrets prior to corruption. Previous feasibility results for adaptively secure MPC in this setting applied either to deterministic functionalities or to randomized functionalities which satisfy a certain technical requirement. The question whether adaptive security is possible for all...... functionalities was left open. We provide the first convincing evidence that the answer to this question is negative, namely that some (randomized) functionalities cannot be realized with adaptive security. We obtain this result by studying the following related invertible sampling problem: given an efficient...

  1. Scalar field cosmologies with inverted potentials

    International Nuclear Information System (INIS)

    Boisseau, B.; Giacomini, H.; Polarski, D.

    2015-01-01

    Regular bouncing solutions in the framework of a scalar-tensor gravity model were found in a recent work. We reconsider the problem in the Einstein frame (EF) in the present work. Singularities arising at the limit of physical viability of the model in the Jordan frame (JF) are either of the Big Bang or of the Big Crunch type in the EF. As a result we obtain integrable scalar field cosmological models in general relativity (GR) with inverted double-well potentials unbounded from below which possess solutions regular in the future, tending to a de Sitter space, and starting with a Big Bang. The existence of the two fixed points for the field dynamics at late times found earlier in the JF becomes transparent in the EF

  2. Scalar field cosmologies with inverted potentials

    Energy Technology Data Exchange (ETDEWEB)

    Boisseau, B.; Giacomini, H. [Université de Tours, Laboratoire de Mathématiques et Physique Théorique, CNRS/UMR 7350, 37200 Tours (France); Polarski, D., E-mail: bruno.boisseau@lmpt.univ-tours.fr, E-mail: hector.giacomini@lmpt.univ-tours.fr, E-mail: david.polarski@umontpellier.fr [Université Montpellier and CNRS, Laboratoire Charles Coulomb, UMR 5221, F-34095 Montpellier (France)

    2015-10-01

    Regular bouncing solutions in the framework of a scalar-tensor gravity model were found in a recent work. We reconsider the problem in the Einstein frame (EF) in the present work. Singularities arising at the limit of physical viability of the model in the Jordan frame (JF) are either of the Big Bang or of the Big Crunch type in the EF. As a result we obtain integrable scalar field cosmological models in general relativity (GR) with inverted double-well potentials unbounded from below which possess solutions regular in the future, tending to a de Sitter space, and starting with a Big Bang. The existence of the two fixed points for the field dynamics at late times found earlier in the JF becomes transparent in the EF.

  3. Analytical modeling of inverted annular film boiling

    International Nuclear Information System (INIS)

    Analytis, G.T.; Yadigaroglu, G.

    1987-01-01

    By employing a two-fluid formulation similar to the one used in the most recent LWR accident analysis codes, a model for the Inverted Annular Film Boiling region is developed. The conservation equations, together with appropriate closure relations are solved numerically. Successful comparisons are made between model predictions and heat transfer coefficient distributions measured in a series of single-tube reflooding experiments. Generally, the model predicts correctly the dependence of the heat transfer coefficient on liquid subcooling and flow rate; for some cases, however, heat transfer is still under-predicted, and an enhancement of the heat exchange from the liquid-vapour interface to the bulk of the liquid is required. The importance of the initial conditions at the quench front is also discussed. (orig.)

  4. Analytical modeling of inverted annular film boiling

    International Nuclear Information System (INIS)

    Analytis, G.T.; Yadigaroglu, G.

    1985-01-01

    By employing a two-fluid formulation similar to the one used in the most recent LWR accident analysis codes, a model for the Inverted Annular Film Boiling region is developed. The conservation equations, together with appropriate constitutive relations are solved numerically and successful comparisons are made between model predictions and heat transfer coefficient distributions measured in a series of single-tube reflooding experiments. The model predicts generally correctly the dependence of the heat transfer coefficient on liquid subcooling and flow rate, through, for some cases, heat transfer is still under-predicted, and an enhancement of the heat exchange from the liquid-vapour interface to the bulk of the liquid is required

  5. Transistorized PWM inverter-induction motor drive system

    Science.gov (United States)

    Peak, S. C.; Plunkett, A. B.

    1982-01-01

    This paper describes the development of a transistorized PWM inverter-induction motor traction drive system. A vehicle performance analysis was performed to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of inverter and motor specifications. The inverter was a transistorized three-phase bridge using General Electric power Darlington transistors. The description of the design and development of this inverter is the principal object of this paper. The high-speed induction motor is a design which is optimized for use with an inverter power source. The primary feedback control is a torque angle control with voltage and torque outer loop controls. A current-controlled PWM technique is used to control the motor voltage. The drive has a constant torque output with PWM operation to base motor speed and a constant horsepower output with square wave operation to maximum speed. The drive system was dynamometer tested and the results are presented.

  6. Evaluation of a high power inverter for potential space applications

    Science.gov (United States)

    Guynes, B. V.; Lanier, J. R., Jr.

    1976-01-01

    The ADM-006 inverter discussed utilizes a unique method of using power switching circuits to produce three-phase low harmonic content voltages without any significant filtering. This method is referred to as the power center approach to inverter design and is explained briefly. The results are presented of tests performed by MSFC to evaluate inverter performance, especially when required to provide power to nonlinear loads such as half or full wave rectified loads with capacitive filtering. Test preocedures and results are described. These tests show that the power center inverter essentially met or exceeded all of claims excluding voltage regulation (3.9 percent versus specified 3.3 percent) and would be a good candidate for high power inverter applications such as may be found on Space Station, Spacelab, etc.

  7. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during...... the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6, neutral point...... clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their nonoptimized...

  8. Miocardiopatía por estrés (miocardiopatía tipo takotsubo: presentación de un caso clínico y revisión de la literatura Stress cardiomyopathy (Takotsubo: case presentation and literature review

    Directory of Open Access Journals (Sweden)

    Edinson García

    2006-08-01

    Full Text Available La miocardiopatía por estrés o tipo takotsubo es un síndrome de aturdimiento miocárdico intenso, precipitado por situaciones de estrés agudo asociado con liberación suprafisiológica de catecolaminas. La disfunción ventricular izquierda es severa, característicamente reversible y de muy buen pronóstico. La arteriografía coronaria no demuestra lesiones coronarias significativas y la elevación de las enzimas de daño miocárdico es leve. También se conoce como miocardiopatía tipo takotsubo o como abombamiento apical transitorio del ventrículo izquierdo. Afecta con mayor frecuencia a mujeres ancianas y rara vez al hombre. Se presenta el caso clínico de una paciente con este tipo de miocardiopatía en el que se hace una revisión de la literatura, con énfasis en su forma de presentación clínica, hallazgos del electrocardiograma, enzimas cardiacas, alteraciones características de la contractilidad, fisiopatología, pronóstico y tratamiento.Stress cardiomyopathy -Takotsubo cardiomyopathy- is a syndrome of intense myocardial stunning, resulting from acute stress situations accompanied by high catecholamine release. It is also known as Takotsubo cardiomyopathy or as transient apical left ventricular ballooning. Left ventricular systolic dysfunction is severe, reversible and has a good prognosis. Coronary arteriography doesn’t show significant coronary lesions and the serum enzymes elevation is minor. It affects predominantly old women and is very rare in men. A case of an old patient with this type of cardiomyopathy is presented and a review of literature is made, emphasizing its clinical manifestations, electrocardiographic findings, cardiac serum enzymes, characteristic contractility alterations, physiopathology, prognosis and treatment.

  9. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters

    Directory of Open Access Journals (Sweden)

    Ali Algaddafi

    2017-01-01

    Full Text Available Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.

  10. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters.

    Science.gov (United States)

    Algaddafi, Ali; Altuwayjiri, Saud A; Ahmed, Oday A; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.

  11. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters

    Science.gov (United States)

    Altuwayjiri, Saud A.; Ahmed, Oday A.; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances. PMID:28540362

  12. Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nelson, Austin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Brian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bell, Frances [SolarCity, San Mateo, CA (United States); McCarty, Michael [SolarCity, San Mateo, CA (United States)

    2016-07-01

    As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC

  13. Cardiopatía de estrés o síndrome de Tako-Tsubo: conceptos actuales

    Directory of Open Access Journals (Sweden)

    Juan C. García-Rubira

    2009-01-01

    Full Text Available El síndrome de Tako-Tsubo, también conocido como cardiopatía de estrés o apical ballooning,representa una entidad recientemente descripta que mimetiza muchas de las característicasde un síndrome coronario agudo, clínicas, analíticas, electrocardiográficas y ecocardiográficas.La presencia de arterias coronarias sin obstrucciones significativas y la forma típicaen la ventriculografía, junto con la ulterior recuperación total del ventrículo apoyan eldiagnóstico. Se observa generalmente en mujeres posmenopáusicas y es frecuente la presenciade una situación estresante, tanto física como emocional. El tratamiento, empíricamente,es similar al del infarto agudo de miocardio, con especial atención en la introducciónde betabloqueantes y anticoagulación. Aunque durante el momento agudo es una patologíano exenta de complicaciones, predominantemente insuficiencia cardíaca, a largo plazo tienebuen pronóstico y su recurrencia es rara. En la presente revisión se discuten estos aspectos,así como la fisiopatología de este síndrome, cuyo diagnóstico es cada vez más frecuenteen nuestro medio.REV ARGENT CARDIOL 2009;77:218-223.

  14. Hemorrhagic Onset of Hemangioblastoma Located in the Dorsal Medulla Oblongata Presenting with Tako-Tsubo Cardiomyopathy and Neurogenic Pulmonary Edema: A Case Report

    Directory of Open Access Journals (Sweden)

    Masayuki Gekka

    2014-03-01

    Full Text Available Here, we present a case of dorsal medulla oblongata hemangioblastoma with fourth ventricular hemorrhage. A 23-year-old female developed sudden consciousness disturbance, and CT revealed hemorrhage in all cerebral ventricles and a hyperdense mass in the cisterna magna. Although the reddish tumor located in the dorsal medulla oblongata was successfully removed, she suffered from severe tako-tsubo cardiomyopathy (TTC and neurogenic pulmonary edema (NPE because of baroreflex failure and damage to the solitary tract nuclei. After intensive care for 12 weeks following surgery, she was discharged without any neurological or radiological deficits. Pathogenesis of TTC/NPE is discussed in this paper.

  15. Takotsubo cardiomyopathy associated with sepsis due to Pseudomonas aeruginosa pneumoniadoi: 10.12662/2317-3076jhbs.v3i4.169.p242-244.2015

    Directory of Open Access Journals (Sweden)

    Márcio da Silva Pereira

    2015-12-01

    Full Text Available The authors describe a case report of a 71 year-old female patient admitted at the emergency service due to severe precordial chest pain associated with dyspnea and sweating. The electrocardiogram performed on admission showed ST elevation on V2 and V3 leads and the ventriculography revealed left ventricular apical ballooning, denoting the diagnosis of Takotsubo Cardiomyopathy. At the eighth day of hospitalization, although the heart function was recovered, the patient died due the clinical complications of a septic shock.

  16. Inverted edge effects on carbon stocks in human-dominated landscapes

    Science.gov (United States)

    Romitelli, I.; Keller, M.; Vieira, S. A.; Metzger, J. P.; Reverberi Tambosi, L.

    2017-12-01

    Although the importance of tropical forests to regulate greenhouse gases is well documented, little is known about what factors affect the ability of these forests to store carbon in human-dominated landscapes. Among those factors, the landscape structure, particularly the amount of forest cover, the type of matrix and edge effects, can have important roles. We tested how carbon stock is influenced by a combination of factors of landscape composition (pasture and forest cover), landscape configuration (edge effect) and relief factors (slope, elevation and aspect). To test those relationships, we performed a robust carbon stock estimation with inventory and LiDAR data in human-dominated landscapes from the Brazilian Atlantic forest region. The study area showed carbon stock mean 45.49 ± 9.34 Mg ha-1. The interaction between forest cover, edge effect and slope was the best combination explanatory of carbon stock. We observed an inverted edge effect pattern where carbon stock is higher close to the edges of the studied secondary forests. This inverted edge effect observed contradicts the usual pattern reported in the literature for mature forests. We suppose this pattern is related with a positive effect that edge conditions can have stimulating forest regeneration, but the underlying processes to explain the observed pattern should still be tested. Those results suggest that Carbon stocks in human-dominated and fragmented landscapes can be highly affected by the landscape structure, and particularly that edges conditions can favor carbon sequestration in regenerating tropical forests.

  17. Electric machine and current source inverter drive system

    Science.gov (United States)

    Hsu, John S

    2014-06-24

    A drive system includes an electric machine and a current source inverter (CSI). This integration of an electric machine and an inverter uses the machine's field excitation coil for not only flux generation in the machine but also for the CSI inductor. This integration of the two technologies, namely the U machine motor and the CSI, opens a new chapter for the component function integration instead of the traditional integration by simply placing separate machine and inverter components in the same housing. Elimination of the CSI inductor adds to the CSI volumetric reduction of the capacitors and the elimination of PMs for the motor further improve the drive system cost, weight, and volume.

  18. Asymmetrical and symmetrical embedded Z-source inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Li, D.

    2011-01-01

    This study presents two types of embedded Z-source inverters with each type further divided into asymmetrical and symmetrical realisations. Being different from their traditional counterparts, the presented inverters have their dc sources inserted within their X-shaped impedance networks so...... ends, which indirectly translates to a lowering of overall system cost. These noted advantages are indeed appropriate for applications like photovoltaic and fuel cell energy harnessing, and have already been confirmed in simulation and experimentally using a laboratory-implemented inverter prototype....

  19. Flash Welding Control by Use of PWM Inverter Power Supply

    Science.gov (United States)

    Nagura, Kouki; Sato, Yukihiko; Yamamura, Naoki; Ishida, Muneaki

    The flash welding is characterized by the high quality, the high production efficiency and the large sectional area welding, and is used to weld rails and hot coils in shop welding mainly. In order to realize high accuracy and high response control of flash welding, the inverter technology has been applied to flash welding in this study. In this paper, a method of process control combined with inverter flash control and mechanical control is proposed. Experiment results of the proposed process control combined with inverter flash control and mechanical control are presented.

  20. Component-Minimized Buck-Boost Voltage Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    . In order to form a distinct neutral potential in the corresponding voltage boost circuitry for correct B4 inverter operation, necessary modifications are derived step by step. The resulted dc networks with symmetrical placement of passive components allow complete charging and equal energy distribution...... semiconductors. Besides the advantage of reduced active components, buck-boost B4 inverters use a little more passive components when compared with buck-boost B6 inverters, which would allow a selectable tradeoff in practice. Moreover, analysis for discontinuous conduction mode of inductor current reveals...

  1. Power Inverter Topologies for Photovoltaic Modules - A Review

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Pedersen, John Kim; Blaabjerg, Frede

    2002-01-01

    This review-paper focuses on the latest development of inverters for photovoltaic AC-Modules. The power range for these inverters is usually within 90 Watt to 500 Watt, which covers the most commercial photovoltaic-modules. Self-commutated inverters have replaced the grid-commutated ones. The same...... is true for the bulky low-frequency transformers versus the high-frequency transformers, which are used to adapt the voltage level. The AC-Module provides a modular design and a flexible behaviour in various grid conditions. It hereby opens the market for photovoltaic-power for everyone at a low cost due...

  2. Discontinuous interleaving of parallel inverters for efficiency improvement

    DEFF Research Database (Denmark)

    Rannestad, Bjørn; Munk-Nielsen, Stig; Gadgaard, Kristian

    2017-01-01

    Interleaved switching of parallel inverters has previously been proposed for efficiency/size improvements of grid connected three-phase inverters. This paper proposes a novel interleaving method which practically eliminates insulated gate bipolar transistor (IGBT) turn-on losses and drastically...... reduces diode reverse recovery losses. The reduction in switching losses are obtained by interleaving two parallel inverter branches so that only one branch conducts the load current at a time. By placing saturable inductors between the parallel branches, soft switching may be obtained, and thereby...

  3. Closed-loop waveform control of boost inverter

    DEFF Research Database (Denmark)

    Zhu, Guo Rong; Xiao, Cheng Yuan; Wang, Haoran

    2016-01-01

    The input current of single-phase inverter typically has an AC ripple component at twice the output frequency, which causes a reduction in both the operating lifetime of its DC source and the efficiency of the system. In this paper, the closed-loop performance of a proposed waveform control method...... to eliminate such a ripple current in boost inverter is investigated. The small-signal stability and the dynamic characteristic of the inverter system for input voltage or wide range load variations under the closed-loop waveform control method are studied. It is validated that with the closedloop waveform...

  4. Ground Fault Overvoltage With Inverter-Interfaced Distributed Energy Resources

    Energy Technology Data Exchange (ETDEWEB)

    Ropp, Michael; Hoke, Anderson; Chakraborty, Sudipta; Schutz, Dustin; Mouw, Chris; Nelson, Austin; McCarty, Michael; Wang, Trudie; Sorenson, Adam

    2017-04-01

    Ground Fault Overvoltage can occur in situations in which a four-wire distribution circuit is energized by an ungrounded voltage source during a single phase to ground fault. The phenomenon is well-documented with ungrounded synchronous machines, but there is considerable discussion about whether inverters cause this phenomenon, and consequently whether inverters require effective grounding. This paper examines the overvoltages that can be supported by inverters during single phase to ground faults via theory, simulation and experiment, identifies the relevant physical mechanisms, quantifies expected levels of overvoltage, and makes recommendations for optimal mitigation.

  5. A PWM transistor inverter for an ac electric vehicle drive

    Science.gov (United States)

    Slicker, J. M.

    1981-01-01

    A prototype system consisting of closely integrated motor, inverter, and transaxle has been built in order to demonstrate the feasibility of a three-phase ac transistorized inverter for electric vehicle applications. The microprocessor-controlled inverter employs monolithic power transistors to drive an oil-cooled, three-phase induction traction motor at a peak output power of 30 kW from a 144 V battery pack. Transistor safe switching requirements are discussed, and a circuit is presented for recovering trapped snubber inductor energy at transistor turn-off.

  6. LCCT-derived three-level three-phase inverters

    DEFF Research Database (Denmark)

    Shults, Tatiana; Husev, Oleksandr; Blaabjerg, Frede

    2017-01-01

    Solutions for a family of the novel three-level neutral-point-clamped (NPC) inductor-capacitor-capacitor-transformer (LCCT)-derived three-phase inverters are described and compared. Component design guidelines and steady state analysis, current and voltage waveforms are given. The authors......' simulation results confirm the theoretical predictions. It was found that an asymmetrical three-level NPC LCCT-derived inverter with a single diode in the impedance source network is the most promising solution. Experimental results for an asymmetrical three-level NPC LCCT-derived inverter with a single...

  7. An iterative method to invert the LTSn matrix

    Energy Technology Data Exchange (ETDEWEB)

    Cardona, A.V.; Vilhena, M.T. de [UFRGS, Porto Alegre (Brazil)

    1996-12-31

    Recently Vilhena and Barichello proposed the LTSn method to solve, analytically, the Discrete Ordinates Problem (Sn problem) in transport theory. The main feature of this method consist in the application of the Laplace transform to the set of Sn equations and solve the resulting algebraic system for the transport flux. Barichello solve the linear system containing the parameter s applying the definition of matrix invertion exploiting the structure of the LTSn matrix. In this work, it is proposed a new scheme to invert the LTSn matrix, decomposing it in blocks and recursively inverting this blocks.

  8. Mujer de 52 años con shock cardiogénico secundario a síndrome de takotsubo tras reparación quirúrgica de la válvula mitral

    OpenAIRE

    Rodríguez Rodrigo, Francisco J.; Medina Peralta, Juan; Alegría Barrero, Ana; Velásquez Arias, Eddy; Unzué, Leyre; González Pinto, Angel

    2014-01-01

    Presentamos un caso de miocardiopatía de takotsubo en una paciente con insuficiencia valvular mitral severa (por prolapso severo del velo posterior), acaecida después de la reparación quirúrgica de dicha válvula. Hasta donde conocemos, este es el primer caso descrito en la literatura.

  9. Pathologic Collision of Inverted Papilloma with Esthesioneuroblastoma

    Directory of Open Access Journals (Sweden)

    Sana D Karam

    2014-03-01

    Full Text Available Background: Inverted papilloma (IP of the nasal cavity is a benign tumor that 0.5-4% of all nasal tumors and have been known to rarely undergo malignant transformation to squamous carcinoma an even more rarely adenocarcinoma. Synchronous association with low grade esthesioneuroblastoma (ENB has been reported in only one case report where a small sized lesion was treated with surgery alone. Here we report the first case of invasion of IP by high grade ENB with nodal metastasis that was treated with combined modality therapy.Case Presentation: A case of a 64 year-old African American gentleman presented to the otolaryngology with a three-month history of recurrent epistaxis. Imaging revealed a large right nasal cavity mass extending into the right sphenoid sinus but without intracranial extension. Surgical pathology revealed high grade ENB invading IP. An orbitofrontal craniotomy approach was used to achieve complete resection of the mass but with positive margins. Postoperative PET/CT showed nodal metastasis. The patient was then treated with adjuvant chemoradiation and remains without evidence of disease at 42 months post-treatment. We discuss the disease presentation, histopathologic features, and disease management with literature support.Conclusion: In this very rare disease presentation where two extremely rare malignancies collide, we show that aggressive management with trimodality therapy of surgery, adjuvant radiation with stereotactic radiosurgical boost, and adjuvant chemotherapy gives excellent results. Given the natural history of the disease, however, long follow up is needed to declare complete freedom from the disease.

  10. Inverted Leidenfrost-like Effect during Condensation.

    Science.gov (United States)

    Narhe, Ramchandra; Anand, Sushant; Rykaczewski, Konrad; Medici, Marie-Gabrielle; González-Viñas, Wenceslao; Varanasi, Kripa K; Beysens, Daniel

    2015-05-19

    Water droplets condensing on solidified phase change materials such as benzene and cyclohexane near their melting point show in-plane jumping and continuous "crawling" motion. The jumping drop motion has been tentatively explained as an outcome of melting and refreezing of the materials surface beneath the droplets and can be thus considered as an inverted Leidenfrost-like effect (in the classical case vapor is generated from a droplet on a hot substrate). We present here a detailed investigation of jumping movements using high-speed imaging and static cross-sectional cryogenic focused ion beam scanning electron microscope imaging. Our results show that drop motion is induced by a thermocapillary (Marangoni) effect. The in-plane jumping motion can be delineated to occur in two stages. The first stage occurs on a millisecond time scale and comprises melting the substrate due to drop condensation. This results in droplet depinning, partial spreading, and thermocapillary movement until freezing of the cyclohexane film. The second stage occurs on a second time scale and comprises relaxation motion of the drop contact line (change in drop contact radius and contact angle) after substrate freezing. When the cyclohexane film cannot freeze, the droplet continuously glides on the surface, resulting in the crawling motion.

  11. Inverted Metamorphic Multijunction (IMM) Cell Processing Instructions

    Energy Technology Data Exchange (ETDEWEB)

    Duda, A.; Ward, S.; Young, M.

    2012-02-01

    This technical report details the processing schedule used to fabricate Inverted Metamorphic Multijunction (IMM) concentrator solar cells at The National Renewable Energy Laboratory (NREL). These devices are used as experimental test structures to support the research at NREL that is focused on increasing the efficiency of photovoltaic power conversion. They are not intended to be devices suitable for deployment in working concentrator systems primarily because of heat sinking issues. The process schedule was developed to be compatible with small sample sizes and to afford relatively rapid turn-around times, in support of research efforts. The report describes the use of electro deposition of gold for both the back and front contacts. Electro-deposition is used because of its rapid turn around time and because it is a benign metallization technique that is seldom responsible for damage to the semiconductors. The layer transfer technique is detailed including the use of a commercially available adhesive and the etching away of the parent gallium arsenide substrate. Photolithography is used to define front contact grids as well as the mesa area of the cell. Finally, the selective wet chemical etchant system is introduced and its use to reveal the back contact is described.

  12. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters

    OpenAIRE

    Algaddafi, Ali; Altuwayjiri, Saud A.; Ahmed, Oday A.; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topol...

  13. High Radiation Resistance Inverted Metamorphic Solar Cell, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation in this SBIR Phase II project is the development of a unique triple junction inverted metamorphic technology (IMM), which will enable the...

  14. Multilayer Control for Inverters in Parallel Operation without Intercommunications

    DEFF Research Database (Denmark)

    Hua, Ming; Hu, Haibing; Xing, Yan

    2012-01-01

    In this paper, a multilayer control is proposed for inverters able to operate in parallel without intercommunications. The first control layer is an improved droop method that introduces power proportional terms into the conventional droop scheme, letting both active and reactive power to be shared...... among the inverters. The second layer is designed to compensate the voltage deviations caused by the mentioned droop control, thus improving the load-voltage regulation of the system. The third layer is a quasi-synchronization control aiming to roughly adjust the angle of the inverter to be close...... to the common ac bus. This layer ensures that the phase difference of each inverter inside a limited margin with the help of the phase signal sensed from the common ac bus. The principle of operation of the control scheme has been analyzed in detail. A small-signal model has been developed in order to study...

  15. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede

    2013-01-01

    During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the selected...... topology and control strategy but also on the characteristics of the employed components. The aim of this paper is evaluate the effect of physical variations associated to the main components on the overall efficiency of PV inverters. It is concluded that a statistical evaluation of the power converter...... provides a better understanding of the PV inverter performance and, in this sense, the definition of the European Efficiency must be reviewed in order to show the quality of the manufactured product....

  16. Study of Inverted Pendulum Robot Using Fuzzy Servo Control Method

    Directory of Open Access Journals (Sweden)

    Dazhong Wang

    2012-09-01

    Full Text Available The inverted pendulum robot is a classical problem in controls. The inherit instabilities in the setup make it a natural target for a control system. Inverted pendulum robot is suitable to use for investigation and verification of various control methods for dynamic systems. Maintaining an equilibrium position of the pendulum pointing up is a challenge as this equilibrium position is unstable. As the inverted pendulum robot system is nonlinear it is well-suited to be controlled by fuzzy logic. In this paper, Lagrange method has been applied to develop the mathematical model of the system. The objective of the simulation to be shown using the fuzzy control method can stabilize the nonlinear system of inverted pendulum robot.

  17. Improving Advanced Inverter Control Convergence in Distribution Power Flow

    Energy Technology Data Exchange (ETDEWEB)

    Nagarajan, Adarsh; Palmintier, Bryan; Ding, Fei; Mather, Barry; Baggu, Murali

    2016-11-21

    Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

  18. Triple inverter pierce oscillator circuit suitable for CMOS

    Science.gov (United States)

    Wessendorf,; Kurt, O [Albuquerque, NM

    2007-02-27

    An oscillator circuit is disclosed which can be formed using discrete field-effect transistors (FETs), or as a complementary metal-oxide-semiconductor (CMOS) integrated circuit. The oscillator circuit utilizes a Pierce oscillator design with three inverter stages connected in series. A feedback resistor provided in a feedback loop about a second inverter stage provides an almost ideal inverting transconductance thereby allowing high-Q operation at the resonator-controlled frequency while suppressing a parasitic oscillation frequency that is inherent in a Pierce configuration using a "standard" triple inverter for the sustaining amplifier. The oscillator circuit, which operates in a range of 10 50 MHz, has applications for use as a clock in a microprocessor and can also be used for sensor applications.

  19. Multilevel inverter switching controller using a field programmable ...

    African Journals Online (AJOL)

    Conducted simulation and measurement results verified and validated the switching controller design functionality and requirement. Keywords: multilevel inverter, switching controller; FPGA, general purpose processor (GPP);digital signal processing (DSP); IGBT; Verilog, power consumption; harmonic elimination (SHE).

  20. Development, Fabrication, and Testing of Inverter Power System for Metroliner

    Science.gov (United States)

    1979-11-01

    This report documents the development and subsequent fabrication of a solid state auxiliary power conditioning unit (APCU) for the upgraded Metroliner. The APCU is an inverter of the pulse width modulated type having multiple parallel transistors in ...

  1. Diode-Assisted Buck-Boost Voltage-Source Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    , a number of diode-assisted inverter variants can be designed with each having its own operational principle and voltage gain expression. For controlling them, a generic modulation scheme that can be used for controlling all diode-assisted variants with minimized harmonic distortion and component stress......This paper proposes a number of diode-assisted buck-boost voltage-source inverters with a unique X-shaped diode-capacitor network inserted between the inverter circuitry and dc source for producing a voltage gain that is comparatively higher than those of other buck-boost conversion techniques....... Using the diode-assisted network, the proposed inverters can naturally configure themselves to perform capacitive charging in parallel and discharging in series to give a higher voltage multiplication factor without compromising waveform quality. In addition, by adopting different front-end circuitries...

  2. Tri-State Current Source Inverter With Improved Dynamic Performance

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Wong, Chow Pang

    2008-01-01

    Traditional dc-ac current source inverter (CSI) has a right-half-plane (RHP) zero in its control-to-output transfer function. This RHP zero causes the inverter output to fall before rising when a step increase in command reference is required (commonly known as non-minimum-phase effect). To achieve...... sequence, the inductive boosting and discharging intervals can be decoupled, allowing the RHP zero to be eliminated with only minor circuit modifications (high level control schemes like predictive and multiloop voltage/current control remain unchanged). The designed inverter can be controlled using...... a better dynamic response, this paper proposes the design of a tri-state CSI using only an additional semiconductor switch for introducing unique freewheeling states to the traditional six active and three null states of a CSI. With the freewheeling states inserted appropriately within the inverter state...

  3. Sideband-Harmonic Instability of Paralleled Inverters with Asynchronous Carriers

    DEFF Research Database (Denmark)

    Yang, Dongsheng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Paralleled inverters with asynchronous carriers are increasingly emerging into renewable power plants and other power-electronic-based power systems. The sideband harmonics resulting from the pulse width modulation tend to be different from one inverter to another, which may trigger sideband-harmonic...... resonances among the paralleled inverters. To address the sideband-harmonic instability, the nonlinearity of the digital pulse width modulator is analyzed first in this paper based on the harmonic balance principle. It is revealed that the dynamic sideband components corresponding to a given small......-signal perturbation can be far below the Nyquist frequency, and they may not be effectively attenuated by anti-aliasing filters. A multi-frequency impedance model is then developed for the inverter, which characterizes the dynamic coupling between the perturbed frequency component and the sideband frequency component...

  4. Six transformer based asymmetrical embedded Z-source inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Poh Chiang, Loh; Chi, Jin

    2013-01-01

    Embedded/Asymmetrical embedded Z-source inverters were proposed to maintain smooth input current/voltage across the dc source and within the impedance network, remain the shoot-through feature used to boost up the dc-link voltage without adding bulky filter at input side. This paper introduces a ...... a class of transformer based asymmetrical embedded Z-source inverters which keep the smooth input current and voltage while achieving enhanced voltage boost capability. The presented inverters are verified by laboratory prototypes experimentally.......Embedded/Asymmetrical embedded Z-source inverters were proposed to maintain smooth input current/voltage across the dc source and within the impedance network, remain the shoot-through feature used to boost up the dc-link voltage without adding bulky filter at input side. This paper introduces...

  5. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    The DC/AC inverters are the key elements in grid-connected PV energy production systems. In this paper, new design optimization techniques focused on transformerless (very high efficiency) PV inverters are proposed. They have been developed based on an analysis of the deficiencies of the current......, state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered....... The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy injected into the electric grid by the optimized PV installation....

  6. High Radiation Resistance Inverted Metamorphic Solar Cell Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation in the proposed SBIR Phase I project is the development of a unique triple unction inverted metamorphic technology (IMM), which will enable the...

  7. An inverter/controller subsystem optimized for photovoltaic applications

    Science.gov (United States)

    Pickrell, R. L.; Merrill, W. C.; Osullivan, G.

    1978-01-01

    Conversion of solar array dc power to ac power stimulated the specification, design, and simulation testing of an inverter/controller subsystem tailored to the photovoltaic power source characteristics. This paper discusses the optimization of the inverter/controller design as part of an overall Photovoltaic Power System (PPS) designed for maximum energy extraction from the solar array. The special design requirements for the inverter/controller include: (1) a power system controller (PSC) to control continuously the solar array operating point at the maximum power level based on variable solar insolation and cell temperatures; and (2) an inverter designed for high efficiency at rated load and low losses at light loadings to conserve energy. It must be capable of operating connected to the utility line at a level set by an external controller (PSC).

  8. Inverted base pavements : new field test and design catalogue.

    Science.gov (United States)

    2014-01-01

    The current economic situation has severely affected the US road infrastructure and funding has become : inadequate for either maintenance or future growth. : The inverted base pavement structure is a promising alternative to achieve high quality roa...

  9. Resistance Spot Welding with Middelfrequency-Inverter Weling Gun

    DEFF Research Database (Denmark)

    Rasmussen, Mogens H.

    The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun......The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun...

  10. Inverter-based circuit design techniques for low supply voltages

    CERN Document Server

    Palani, Rakesh Kumar

    2017-01-01

    This book describes intuitive analog design approaches using digital inverters, providing filter architectures and circuit techniques enabling high performance analog circuit design. The authors provide process, supply voltage and temperature (PVT) variation-tolerant design techniques for inverter based circuits. They also discuss various analog design techniques for lower technology nodes and lower power supply, which can be used for designing high performance systems-on-chip.    .

  11. A case report of inverted papilloma of the posterior urethra

    OpenAIRE

    徳光, 正行; 井内, 裕満; 森川, 満; 八竹, 直

    1992-01-01

    A case of inverted papilloma of the posterior urethra is reported. A 59-year-old male was admitted with the chief complaint of hematuria. Urethrogram revealed a small defect in the neck of the bladder. Endoscopic examination revealed a polypoid tumor on the stalk arising from prostatic urethra, and transurethral resection was performed. The patient has been subsequently followed up and there has been no evidence of recurrence. Although 141 cases of inverted papilloma have been reported in man...

  12. A case report of inverted papilloma of the posterior urethra

    OpenAIRE

    長谷川, 総一郎; 絹川, 常郎; 松浦, 治; 竹内, 宜久; 服部, 良平; 小野, 佳成; 大島, 伸一; 村上, 榮

    1987-01-01

    Sixty-seven cases of inverted papilloma have been reported in many anatomical sites of urinary tract but only 9 cases involving the posterior urethra have been described in Japan. We report the 10th case of inverted papilloma of the posterior urethra in a 27-year-old male who complained of macroscopic hematuria. The lesion was diagnosed cystoscopically and treated by transurethral resection.

  13. A Novel Power Electronic Inverter Circuit for Transformerless Photovoltaic Systems

    OpenAIRE

    Hai-Yan, Cao

    2014-01-01

    Capacitive leakage current is one of the most important issues for transformerless photovoltaic systems. In order to deal with the capacitive leakage current, a new power electronic inverter circuit is proposed in this paper. The inverter circuit consists of six switches and operates with constant common mode voltage. Theoretical analysis is conducted to clarify the circuit operation principle and the common mode characteristic. The performance evaluation test is carried out, and test results...

  14. Grounding Effect on Common Mode Interference of Underground Inverter

    OpenAIRE

    CHENG Qiang; CHENG Ning; LI Zhen-shuang

    2013-01-01

    For the neutral point not grounded characteristics of underground power supply system in coal mine, this paper studied common mode equivalent circuit of underground PWM inverter, and extracted parasitic parameters of interference propagation path. The author established a common mode and differential mode model of underground inverter. Taking into account the rise time of PWM, the simulation results of conducted interference by Matlab software is compared with measurement spectrum on the AC s...

  15. Tensor product of left n-invertible operators

    Czech Academy of Sciences Publication Activity Database

    Duggal, B.P.; Müller, Vladimír

    2013-01-01

    Roč. 215, č. 2 (2013), s. 113-125 ISSN 0039-3223 R&D Projects: GA ČR GA201/09/0473 Institutional support: RVO:67985840 Keywords : Banach space * essentially left n- invertible operator * left n-invertible operator Subject RIV: BA - General Mathematics Impact factor: 0.630, year: 2013 http://journals.impan.pl/cgi-bin/doi?sm215-2-2

  16. MPC of Single Phase Inverter for PV System

    OpenAIRE

    Irtaza M. Syed; Kaamran Raahemifar

    2014-01-01

    This paper presents a model predictive control (MPC) of a utility interactive (UI) single phase inverter (SPI) for a photovoltaic (PV) system at residential/distribution level. The proposed model uses single-phase phase locked loop (PLL) to synchronize SPI with the grid and performs MPC control in a dq reference frame. SPI model consists of boost converter (BC), maximum power point tracking (MPPT) control, and a full bridge (FB) voltage source inverter (VSI). No PI regula...

  17. Model Predictive Control of Three Phase Inverter for PV Systems

    OpenAIRE

    Irtaza M. Syed; Kaamran Raahemifar

    2015-01-01

    This paper presents a model predictive control (MPC) of a utility interactive three phase inverter (TPI) for a photovoltaic (PV) system at commercial level. The proposed model uses phase locked loop (PLL) to synchronize the TPI with the power electric grid (PEG) and performs MPC control in a dq reference frame. TPI model consists of a boost converter (BC), maximum power point tracking (MPPT) control, and a three-leg voltage source inverter (VSI). The operational model of ...

  18. Signature Schemes Secure against Hard-to-Invert Leakage

    DEFF Research Database (Denmark)

    Faust, Sebastian; Hazay, Carmit; Nielsen, Jesper Buus

    2012-01-01

    In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information-theoretically re......In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information......-theoretically reveal the entire secret key. In this work, we propose the first constructions of digital signature schemes that are secure in the auxiliary input model. Our main contribution is a digital signature scheme that is secure against chosen message attacks when given an exponentially hard-to-invert function...... of the secret key. As a second contribution, we construct a signature scheme that achieves security for random messages assuming that the adversary is given a polynomial-time hard to invert function. Here, polynomial-hardness is required even when given the entire public-key – so called weak auxiliary input...

  19. Photovoltaic power generating system; Sanso zetsuengata taiyoko inverter

    Energy Technology Data Exchange (ETDEWEB)

    Nojima, T.; Nakashima, T.; Muta, Y.; Takase, K.; Hirayama, K. [Nishimu Electronics Industries Co. Ltd., Saga (Japan)

    1996-10-27

    Nishimu Electronics Industries Co., Ltd. has developed a new series of inverters of three phase photovoltaic power generating system with the output ranging from 10 kVA to 50 kVA. For these inverters, the inverter and the system interconnection protector were integrated to make them smaller, lighter and cheaper. Stand-alone operation function was also added. The DC input voltage ranges were between 240 and 400 V for the crystalline solar cell, and between 170 and 400 V for the amorphous one. From the viewpoint of control of inverters, the inverters are generally controlled by the voltage-type current control method during the interconnection operation, while they must be controlled by the voltage-type voltage control method during the stand-alone operation which is the same as the UPS usually operated alone. For the present inverters, two control circuits for the interconnection operation and for the stand-alone operation were prepared. The control circuits for interconnection and stand-alone operations were switched using a cam-operation switch for change-over of operation. The results of the system interconnection verification tests satisfied the criteria of Japan`s Electronic Products Test Center. 3 refs., 4 figs., 2 tabs.

  20. Characterization of Inverted Polymer Bulk Heterojunction Solar Cells

    Science.gov (United States)

    Carney, Tyler; Tzolov, Marian

    Inverted solar cells were proven to be an improvement over polymer solar cells in terms of durability and reliability. We have fabricated the solar cells using P3HT and PCPDTBT as the active polymer with PC60BM as the electron acceptor. The materials we deposited from solution by spin coating on glass substrates with ITO film. Molybdenum oxide was thermally evaporated overtop the spin coated polymer solar cell to realize the inverted design. The devices were finalized by thermally evaporated aluminum contacts which were then mechanically reinforced with silver paste. Current voltage characteristics were performed both in dark and under illumination to characterize the inverted solar cells and to verify the inverted solar cell design. Impedance spectroscopy in dark and under illumination were used to gain more information about the photoelectric processes in the devices and to build a realistic equivalent circuit model of the inverted solar cells. The inverted solar cells were then compared against standard polymer bulk heterojunction solar cells produced with the same active materials.

  1. Distortion and regulation characterization of a Mapham inverter

    Science.gov (United States)

    Sundberg, Richard C.; Brush, Andrew S.; Button, Robert M.; Patterson, Alexander G.

    1989-01-01

    Output voltage Total Harmonic Distortion (THD) of a 20kHz, 6kVA Mapham resonant inverter is characterized as a function of its switching-to-resonant frequency ratio, f sub s/f sub r, using the EASY5 engineering analysis system. EASY5 circuit simulation results are compared with hardware test results to verify the accuracy of the simulations. The effects of load on the THD versus f sub s/f sub r ratio is investigated for resistive, leading, and lagging power factor load impedances. The effect of the series output capacitor on the Mapham inverter output voltage distortion and inherent load regulation is characterized under loads of various power factors and magnitudes. An optimum series capacitor value which improves the inherent load regulation to better than 3 percent is identified. The optimum series capacitor value is different than the value predicted from a modeled frequency domain analysis. An explanation is proposed which takes into account the conduction overlap in the inductor pairs during steady-state inverter operation, which decreases the effective inductance of a Mapham inverter. A fault protection and current limit method is discussed which allows the Mapham inverter to operate into a short circuit, even when the inverter resonant circuit becomes overdamped.

  2. Self-Oscillating Resonant Gate Drive for Resonant Inverters and Rectifiers Composed Solely of Passive Components

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Pedersen, Jeppe Arnsdorf; Knott, Arnold

    2014-01-01

    to improve the performance of the gate drive and how the gate drive can be implemented in a class E inverter, a class DE inverter and in class E inverter with a synchronous class E rectifier. The paper shows practical implementations of all the proposed inverters and converters operating in the Very High...

  3. Aalborg Inverter - A new type of “Buck in Buck, Boost in Boost” Grid-tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Blaabjerg, Frede

    2013-01-01

    This paper presents a new family of high efficiency DC/AC grid-tied inverter with a wide variation of input DC voltage. It is a kind of “Boost in Boost, Buck in Buck” inverter, meaning that only one power stage works at the high frequency to achieve the minimum switching loss. Furthermore......, the minimum filtering inductance in the power loop is achieved to reduce the conduction power loss whether in “Boost” or “Buck” mode. In theory, it can achieve higher efficiency than other inverters under the same condition of input DC voltage. The principle of operation is fully illustrated through...... the analysis on the equivalent circuits of a “three-level” single-phase inverter. Simulations show it has good control performance....

  4. Analysis of Magnetically-Coupled Impedance Source Three-Phase Four-Switch Inverters

    DEFF Research Database (Denmark)

    Li, Kerui; Abdelhakim, Ahmed; Yang, Yongheng

    2017-01-01

    In this paper, magnetically-coupled impedance source (MCIS) three-phase four-switch inverters are introduced for renewable energy applications. This inverter utilizes two single-phase MCIS inverters to obtain a three-phase output, where less component-count is achieved in order to reduce...... the inverter volume. On the other hand, as a result of the reduced number of switches, the proposed inverter suffers from higher voltage stresses. The MCIS inverters are first reviewed. Then, the modulation and operation principle of the MCIS three-phase inverter topology are introduced before sizing...

  5. Delayed-Type Hypersensitivity to Metals of Environmental Burden in Patients with Takotsubo Syndrome - Is There a Clinical Relevance?

    Directory of Open Access Journals (Sweden)

    Jan Manousek

    Full Text Available Takotsubo syndrome (TS is a heart condition characterised by a sudden transient left ventricular dysfunction; its pathophysiology is probably associated with elevated levels of catecholamines but the exact mechanism is not known as yet. Literature and clinical experience suggest that TS affects persons with various comorbidities. This pilot work aims to evaluate the frequency of comorbidities with potential pathological immune reactivity, and to evaluate the potential association between TS and hypersensitivity to metals assessed by LTT-MELISA®.A total of 24 patients (23 women, 1 man with a history of TS attack and 27 healthy controls were evaluated. Hypersensitivity was evaluated by a lymphocyte transformation test (LTT-MELISA®; a questionnaire of environmental burden was used to select evaluated metals. A total of 19 patients (79% had at least one condition that might potentially be associated with pathological immune reactivity (autoimmune thyroid disease, drug allergy, bronchial asthma, cancer, contact dermatitis, rheumatoid arthritis. Hypersensitivity to metals was identified significantly more frequently in TS patients than in healthy controls (positive reaction to at least one metal was identified in 95.8% of TS patients and in 59.3% of controls; p = 0.003; the difference was statistically significant for mercury (45.8% and 14.8%, respectively; p = 0.029.Our work shows that conditions with pathological immune reactivity occur frequently in TS patients, and our data suggest a possible association between TS and hypersensitivity to metals (mercury in particular evaluated by LTT-MELISA®. We also suggest that apart from the triggering stress factor, potential existence of other serious conditions should be considered when taking medical history of TS patients.

  6. The Inverted Agricultural Economics Classroom: A new way to teach? A new way to learn?

    OpenAIRE

    Gardner, Justin G.

    2012-01-01

    The purpose of this paper is to introduce an emerging teaching method, the inverted classroom, to agricultural economists. The reader will learn the pros and cons of this method and the tools needed to create an inverted course. Data on student perceptions of the inverted classroom is presented, as well as an estimate of the relationship between student perceptions and student performance in an inverted classroom. The surveyed students responded positively to the inverted classroom concept; h...

  7. Breaking Barriers to Low-Cost Modular Inverter Production & Use

    Energy Technology Data Exchange (ETDEWEB)

    Bogdan Borowy; Leo Casey; Jerry Foshage; Steve Nichols; Jim Perkinson

    2005-05-31

    The goal of this cost share contract is to advance key technologies to reduce size, weight and cost while enhancing performance and reliability of Modular Inverter Product for Distributed Energy Resources (DER). Efforts address technology development to meet technical needs of DER market protection, isolation, reliability, and quality. Program activities build on SatCon Technology Corporation inverter experience (e.g., AIPM, Starsine, PowerGate) for Photovoltaic, Fuel Cell, Energy Storage applications. Efforts focused four technical areas, Capacitors, Cooling, Voltage Sensing and Control of Parallel Inverters. Capacitor efforts developed a hybrid capacitor approach for conditioning SatCon's AIPM unit supply voltages by incorporating several types and sizes to store energy and filter at high, medium and low frequencies while minimizing parasitics (ESR and ESL). Cooling efforts converted the liquid cooled AIPM module to an air-cooled unit using augmented fin, impingement flow cooling. Voltage sensing efforts successfully modified the existing AIPM sensor board to allow several, application dependent configurations and enabling voltage sensor galvanic isolation. Parallel inverter control efforts realized a reliable technique to control individual inverters, connected in a parallel configuration, without a communication link. Individual inverter currents, AC and DC, were balanced in the paralleled modules by introducing a delay to the individual PWM gate pulses. The load current sharing is robust and independent of load types (i.e., linear and nonlinear, resistive and/or inductive). It is a simple yet powerful method for paralleling both individual devices dramatically improves reliability and fault tolerance of parallel inverter power systems. A patent application has been made based on this control technology.

  8. Simulation of push-pull inverter using wide bandgap devices

    Science.gov (United States)

    Al-badri, Mustafa; Matin, Mohammed A.

    2016-09-01

    This paper discusses the use of wide bandgap devices (SiC-MOSFET) in the design of a push-pull inverter which provides inexpensive low power dc-ac inverters. The parameters used were 1200V SiC MOSFET(C2M0040120D) made by power company ROHM. This modeling was created using parameters that were provided from a device datasheet. The spice model is provided by this company to study the effect of adding this component on push-pull inverter ordinary circuit and compared results between SiC MOSFET and silicon MOSFET (IRFP260M). The results focused on Vout and Vmos stability as well as on output power and MOSFET power loss because it is a very crucial aspect on DC-AC inverter design. These results are done using the National Instrument simulation program (Multisim 14). It was found that power loss is better in the 12 and 15 vdc inverter. The Vout in the SIC MOSFET circuit shows more stability in the high current low resistance load in comparison to the Silicon MOSFET circuit and this will improve the overall performance of the circuit.

  9. Analysis and Design of Solar Photo voltaic Grid Connected Inverter

    Directory of Open Access Journals (Sweden)

    Muddasani Satyanarayana

    2015-08-01

    Full Text Available This paper presents common mode voltage analysis of single phase grid connected photovoltaic inverter. Many researchers proposed different grid tie inverters for applications like domestic powering, street lighting, water pumping, cooling and heating applications, however traditional grid tie PV inverter uses either a line frequency or a high frequency transformer between the inverter and grid but losses will increase in the network leading to reduced efficiency of the system. In order to increase the efficiency, with reduced size and cost of the system, the effective solution is to remove the isolation transformer. But common mode (CM ground leakage current due to parasitic capacitance between the PV panels and the ground making the system unreliable. The common mode current reduces the efficiency of power conversion stage, affects the quality of grid current, deteriorate the electric magnetic compatibility and give rise to the safety threats. In order to eliminate the common mode leakage current in Transformerless PV systm two control algorithms of multi-carrier pwm are implemented and compared for performance analysis.The shoot-through issue that is encountered by traditional voltage source inverter is analyzed for enhanced system reliability. These control algorithms are compared for common mode voltage and THD comparisons. The proposed system is designed using MATLAB/SIMULINK software for analysis.

  10. Development and Evaluation of a 2KVA Inverter

    Directory of Open Access Journals (Sweden)

    Ajayi Adedayo

    2013-09-01

    Full Text Available A 2KV inverter was designed, developed and tested for household applications. It consists of a heavy duty (24 V, 80 AH, oscillator unit, PWM (Pulse-width modulation controller unit, driver unit, amplifier unit, center-tap step up transformer and battery charger unit. The battery powered the circuitry and the oscillator section generates the drive signal that is amplified and set up the transformer to produce 240 V supply at the secondary winding connected to the output socket of inverter. The feedback control circuit uses discrete components such as: full wave rectifier, pulse width modulator (IC, diodes and other components to sense the output voltage (or load current. When the feedback senses that the load on the inverter output has increased, the inverter control circuitry acts by increasing the width of the switching pulse in the oscillator section which turn on the MOSFETS. MOSFETS turns on for longer time each cycle, automatically correcting the R.M.S value of the output to compensate for any drop in peak-peak output voltage as well as continuous charging of battery, consequently, maintaining a steady output voltage level in inverter irrespective of the load characteristics. The outputs of the tests carried on the unit shows that that instrument performs satisfactory well.

  11. Modeling of a single-phase photovoltaic inverter

    Energy Technology Data Exchange (ETDEWEB)

    Maris, T.I. [Department of Electrical Engineering, Technological Educational Institute of Chalkida, 334 40 Psachna Evias (Greece); Kourtesi, St. [Hellenic Public Power Corporation S.A., 22 Chalcocondyli Str., 104 32 Athens (Greece); Ekonomou, L. [Hellenic American University, 12 Kaplanon Str., 106 80 Athens (Greece); Fotis, G.P. [National Technical University of Athens, School of Electrical and Computer Engineering, High Voltage Laboratory, 9 Iroon Politechniou St., Zografou, 157 80 Athens (Greece)

    2007-11-06

    The paper presents the design of a single-phase photovoltaic inverter model and the simulation of its performance. Furthermore, the concept of moving real and reactive power after coupling this inverter model with an a.c. source representing the main power distribution grid was studied. Brief technical information is given on the inverter design, with emphasis on the operation of the circuit used. In the technical information section, a description of real and reactive power components is given with special reference to the control of these power components by controlling the power angle or the difference in voltage magnitudes between two voltage sources. This a.c. converted voltage has practical interest, since it is useful for feeding small house appliances. (author)

  12. A solution process for inverted tandem solar cells

    DEFF Research Database (Denmark)

    Larsen-Olsen, Thue Trofod; Bundgaard, Eva; Sylvester-Hvid, Kristian O.

    2011-01-01

    Tandem solar cells with normal and inverted device geometries were prepared by a solution process. Both device types were based on the use of zinc(II)oxide as the electron transporting layer (ETL). The hole transporting layer (HTL) was either PEDOT:PSS for normal geometry tandem solar cells...... or vanadium(V)oxide in the case of inverted tandem cells. It was found that the inverted tandem solar cells performed comparable or better than the normal geometry devices, showing that the connection structure of vanadium(V)oxide, Ag nanoparticles and zinc(II)oxide functions both as a good recombination...... layer, ensuring serial connection, and as a solvent barrier, protecting the first photoactive layer from processing of the second layer. This successfully demonstrates a tandem solar cell fabrication process fully compatible with state-of-the-art solution based automated production procedures....

  13. Analysis of Voltage Forming Methods for Multiphase Inverters

    Directory of Open Access Journals (Sweden)

    Tadas Lipinskis

    2013-05-01

    Full Text Available The article discusses advantages of the multiphase AC induction motor over three or less phase motors. It presents possible stator winding configurations for a multiphase induction motor. Various fault control strategies were reviewed for phases feeding the motor. The authors propose a method for quality evaluation of voltage forming algorithm in the inverter. Simulation of a six-phase voltage source inverter, voltage in which is formed using a simple SPWM control algorithm, was performed in Matlab Simulink. Simulation results were evaluated using the proposed method. Inverter’s power stage was powered by 400 V DC source. The spectrum of output currents was analysed and the magnitude of the main frequency component was at least 12 times greater than the next biggest-magnitude component. The value of rectified inverter voltage was 373 V.Article in Lithuanian

  14. Harmonic currents Compensator Grid-Connected Inverter at the Microgrid

    DEFF Research Database (Denmark)

    Asuhaimi Mohd Zin, A.; Naderipour, A.; Habibuddin, M.H.

    2016-01-01

    The main challenge associated with the grid-connected inverter in distributed generation (DG) systems is to maintain the harmonic contents in output current below the specified values and compensates for unbalanced loads even when the grid is subject to disturbances such as harmonic distortion...... and unbalanced loads. To overcome these challenges, a current control strategy for a three-phase grid-connected inverter under unbalanced and nonlinear load conditions is presented. It enables grid-connected inverter by the proposed control method to inject balanced clean currents to the grid even when the local...... loads are unbalanced and/or nonlinear and also compensate of the harmonic currents and control the active and reactive power. The main advantage and objective of this method is to effectively compensate for the harmonic currents content of the grid current and microgrid without using any compensation...

  15. Resonance analysis in parallel voltage-controlled Distributed Generation inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    Thanks to the fast responses of the inner voltage and current control loops, the dynamic behaviors of parallel voltage-controlled Distributed Generation (DG) inverters not only relies on the stability of load sharing among them, but subjects to the interactions between the voltage control loops...... of the inverters and the remaining system dynamics. This paper addresses the later interactions and the consequent resonances through the frequency-domain analysis of the inverters output impedances and the remaining equivalent network impedance. Furthermore, impacts of the virtual output impedance loop...... and the voltage feedforward loop in the current controller are evaluated based on such an impedance interactions analysis. Simulation results are presented to confirm the validity of the theoretical analysis....

  16. Multilevel inverter with optimal THD through the firefly algorithm

    Directory of Open Access Journals (Sweden)

    El Mehdi Belkacem Riadh

    2017-03-01

    Full Text Available Reduction of the Total Harmonic Distortion (THD in multilevel inverters requires resolution of complex nonlinear transcendental equations; in this paper we propose a combination of one of the best existing optimized hardware structures with the recent firefly algorithm, which was used to optimize the THD, through finding the best switching angles and guaranteeing the minimization of harmonics within a user defined bandwidth. The obtained THD through the simulation of the thirteen-level symmetric inverter has been reduced down to 5% (FFT of 60 harmonics. In order to validate the simulation results, a thirteen-level symmetric inverter prototype has been made, and practically experimented and tested with different loads. Consequently, the measured THD with resistive load was 4.7% on a bandwidth of 3 kHz. The main advantage of the achieved work is the reduction of the THD.

  17. Arduino Mega 2560 Microcontroller Built 3-Phase Seven Level Inverter

    Directory of Open Access Journals (Sweden)

    PAVANKUMAR Shriram Mehtre

    2017-10-01

    Full Text Available n this paper, the implementation of 3-phase seven level cascaded H-bridge inverter is discussed with Arduino microcontroller and harmonic analysis is performed using Fourier series. The multilevel inverters (MLI give several benefits as reduced switching voltage stresses and the capability to operate in higher level voltage applications. A new and simple architecture Arduino Mega 2560 microcontroller is employed to produce the control signals for the seven level cascaded H-bridge MLI switches. The computer simulation is carried out in PSIM environment and prototype experimental model is developed with TLP 250 driver ICs and power MOSFET switches to validate the simulation results. The THDs present in different voltage level inverters are mathematically analysed using Fourier series.

  18. Three-phase multilevel solar inverter for motor drive system

    Science.gov (United States)

    Bhasagare, Mayuresh P.

    This thesis deals with three phase inverters and the different control strategies that can be associated with an inverter being used together. The first part of this thesis discusses the present research in the fields of PV panels, motor drive systems and three phase inverters along with their control. This control includes various strategies like MPPT, Volts-Hertz and modulation index compensation. Incorporating these techniques together is the goal of this thesis. A new topology for operating an open end motor drive system has also been discusses, where a boost converter and a flyback converter have been used in cascade to run a three phase motor. The main advantage of this is increasing the number of levels and improving the quality of the output voltage, not to mention a few other benefits of having the proposed circuit. A new algorithm has also been designed for starting and stopping the motor, which controls the current drawn from the power source during starting.

  19. Toroidal transformer design program with application to inverter circuitry

    Science.gov (United States)

    Dayton, J. A., Jr.

    1972-01-01

    Estimates of temperature, weight, efficiency, regulation, and final dimensions are included in the output of the computer program for the design of transformers for use in the basic parallel inverter. The program, written in FORTRAN 4, selects a tape wound toroidal magnetic core and, taking temperature, materials, core geometry, skin depth, and ohmic losses into account, chooses the appropriate wire sizes and number of turns for the center tapped primary and single secondary coils. Using the program, 2- and 4-kilovolt-ampere transformers are designed for frequencies from 200 to 3200 Hz and the efficiency of a basic transistor inverter is estimated.

  20. Dead-Time Generation in Six-Phase Frequency Inverter

    Directory of Open Access Journals (Sweden)

    Aurelijus Pitrėnas

    2016-06-01

    Full Text Available In this paper control of multi-phase induction drives is discussed. Structure of six-phase frequency inverter is examined. The article deals with dead-time generation circuits in six-phase frequency inverter for transistor control signals. Computer models of dead-time circuits is created using LTspice software package. Simulation results are compared with experimental results of the tested dead-time circuits. Parameters obtained in simulation results are close to the parameters obtained in experimental results.

  1. Magneto-optical tweezers built around an inverted microscope

    International Nuclear Information System (INIS)

    Claudet, Cyril; Bednar, Jan

    2005-01-01

    We present a simple experimental setup of magneto-optical tweezers built around an inverted microscope. Two pairs of coils placed around the focal point of the objective generate a planar-rotating magnetic field that is perpendicular to the stretching direction. This configuration allows us to control the rotary movement of a paramagnetic bead trapped in the optical tweezers. The mechanical design is universal and can be simply adapted to any inverted microscope and objective. The mechanical configuration permits the use of a rather large experimental cell and the simple assembly and disassembly of the magnetic attachment

  2. Invertible chaotic fragile watermarking for robust image authentication

    International Nuclear Information System (INIS)

    Sidiropoulos, Panagiotis; Nikolaidis, Nikos; Pitas, Ioannis

    2009-01-01

    Fragile watermarking is a popular method for image authentication. In such schemes, a fragile signal that is sensitive to manipulations is embedded in the image, so that it becomes undetectable after any modification of the original work. Most algorithms focus either on the ability to retrieve the original work after watermark detection (invertibility) or on detecting which image parts have been altered (localization). Furthermore, the majority of fragile watermarking schemes suffer from robustness flaws. We propose a new technique that combines localization and invertibility. Moreover, watermark dependency on the original image and the non-linear watermark embedding procedure guarantees that no malicious attacks will manage to create information leaks.

  3. SiC MOSFETs based split output half bridge inverter

    DEFF Research Database (Denmark)

    Li, Helong; Munk-Nielsen, Stig; Beczkowski, Szymon

    2014-01-01

    output. The double pulse test shows the devices' current during commutation process and the reduced switching losses of SiC MOSFETs compared to that of the traditional half bridge. The efficiency comparison is presented with experimental results of half bridge power inverter with split output...... and traditional half bridge inverter, from switching frequency 10 kHz to 100 kHz. The experimental results comparison shows that the half bridge with split output has an efficiency improvement of more than 0.5% at 100 kHz switching frequency....

  4. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV...

  5. Inverter power module with distributed support for direct substrate cooling

    Science.gov (United States)

    Miller, David Harold [San Pedro, CA; Korich, Mark D [Chino Hills, CA; Ward, Terence G [Redondo Beach, CA; Mann, Brooks S [Redondo Beach, CA

    2012-08-21

    Systems and/or methods are provided for an inverter power module with distributed support for direct substrate cooling. An inverter module comprises a power electronic substrate. A first support frame is adapted to house the power electronic substrate and has a first region adapted to allow direct cooling of the power electronic substrate. A gasket is interposed between the power electronic substrate and the first support frame. The gasket is configured to provide a seal between the first region and the power electronic substrate. A second support frame is adapted to house the power electronic substrate and joined to the first support frame to form the seal.

  6. A Two-Stage Wind Grid Inverter with Boost Converter

    OpenAIRE

    Che, Yanbo; Zhang, Wen; Ge, Leijiao; Zhang, Jijie

    2014-01-01

    At present, the conversion efficiency of commercial small wind grid inverter is low, and, in case of low wind speed, the wind energy cannot be used efficiently. In order to resolve this problem, it is necessary to improve the topological structure and control strategy, and design a new small wind grid inverter. In this paper, we apply a two-voltage stage topology with boost converter. The boost circuit is to achieve the maximum power output of the wind energy by the segmented regulation, whil...

  7. Bistability in a complementary metal oxide semiconductor inverter circuit.

    Science.gov (United States)

    Carroll, Thomas L

    2005-09-01

    Radiofrequency signals can disrupt the operation of low frequency circuits. A digital inverter circuit would seem to be immune to such disruption, because its output state usually jumps abruptly between 0 and 5 V. Nevertheless, when driven with a high frequency signal, the inverter can have two coexisting stable states (which are not at 0 and 5 V). Slow switching between these states (by changing the rf signal) will produce a low frequency signal. I demonstrate the bistability in a circuit experiment and in a simple model of the circuit.

  8. Electronic inverter assembly with an integral snubber capacitor

    Science.gov (United States)

    Singh, Brij N.; Schmit, Christopher J.

    2017-08-01

    A coaxial bus connector has a first end and a second end opposite the first end. The first end has a first positive terminal and a first negative terminal coupled to a primary direct current bus of a primary inverter. The second end has a second positive terminal and a second negative terminal coupled to the secondary direct current bus of a secondary inverter, wherein the coaxial bus connector comprises a dielectric material between a center conductor and a coaxial sleeve to form a snubber capacitor to absorb electrical energy or to absorb voltage spikes.

  9. Inverted opal luminescent Ce-doped silica glasses

    Directory of Open Access Journals (Sweden)

    R. Scotti

    2006-01-01

    Full Text Available Inverted opal Ce-doped silica glasses (Ce : Si molar ratio 1 ⋅ 10−3 were prepared by a sol-gel method using opals of latex microspheres as templates. The rare earth is homogeneously dispersed in silica host matrix, as evidenced by the absence of segregated CeO2, instead present in monolithic Ce-doped SG with the same cerium content. This suggests that the nanometric dimensions of bridges and junctions of the host matrix in the inverted opal structures favor the RE distribution avoiding the possible segregation of CeO2.

  10. Vibrational sum frequency generation spectroscopy using inverted visible pulses.

    Science.gov (United States)

    Weeraman, Champika; Mitchell, Steven A; Lausten, Rune; Johnston, Linda J; Stolow, Albert

    2010-05-24

    We present a broadband vibrational sum frequency generation (BB-VSFG) scheme using a novel ps visible pulse shape. We generate the fs IR pulse via standard procedures and simultaneously generate an 'inverted' time-asymmetric narrowband ps visible pulse via second harmonic generation in the pump depletion regime using a very long nonlinear crystal which has high group velocity mismatch (LiNbO3). The 'inverted' ps pulse shape minimally samples the instantaneous nonresonant response but maximally samples the resonant response, maintaining high spectral resolution. We experimentally demonstrate this scheme, presenting SFG spectra of canonical organic monolayer systems in the C-H stretch region (2800-3000 cm(-1)).

  11. Adaptive control of grid-connected inverters based on online grid impedance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cespedes, Mauricio; Sun, Jian [Rensselaer Polytechnic Institute, Troy, NY (United States). Dept. of Electrical, Computer and Systems Engineering

    2012-07-01

    Stability of a grid-connected inverter depends on the ratio of the grid impedance to the inverter impedance. Since the grid impedance changes during normal power system conditions, this paper uses first an impulse response analysis method built into a grid-connected inverter for online grid impedance identification. Secondly, in order to develop simple adaptation rules for the inverter control system, the grid impedance is assumed inductive, and used to derive, analytically, the stability limits of PLL bandwidth and grid voltage feedforward gains. Experimental measurements demonstrate the online grid impedance identification and the inverter adaptive control implemented together within the DSP of a three-phase grid-connected inverter. (orig.)

  12. Differential diagnosis at admission between Takotsubo cardiomyopathy and acute apical-anterior myocardial infarction in postmenopausal women.

    Science.gov (United States)

    Zorzi, Alessandro; Baritussio, Anna; ElMaghawry, Mohamed; Siciliano, Mariachiara; Migliore, Federico; Perazzolo Marra, Martina; Iliceto, Sabino; Corrado, Domenico

    2016-08-01

    Takotsubo cardiomyopathy (TTC) typically affects postmenopausal women and clinically presents with chest pain, ST-segment elevation, elevated cardiac enzymes and apical left ventricular (LV) wall motion abnormalities that mimic 'apical-anterior' acute myocardial infarction (AMI). This study assessed whether at-admission clinical evaluation helps in differential diagnosis between the two conditions. The study compared at-admission clinical, electrocardiographic (ECG) and echocardiographic findings of 31 women (median age 67 years, interquartile range (IQR) 62-76) with typical TTC and 30 women (median age 73 years, IQR 61-81) with apical-anterior AMI due to acute occlusion of the mid/distal left anterior descending coronary artery. Women with TTC significantly more often showed PR-segment depression (62% versus 3%, p<0.001), J-waves (26% versus 3%, p=0.03), maximum ST-segment elevation ⩽2 mm (84% versus 37%, p<0.001) and ST-segment elevation in lead II (42% versus 10%, p=0.01) than those with AMI. At multivariate analysis, PR-segment depression (odds ratio (OR)=37.2, 95% confidence interval (CI)=3.4-424, p=0.002) and maximum ST-segment elevation ⩽2 mm (OR=11.1, 95% CI=1.7-99.4, p=0.01) remained the only independent predictors of TTC and the co-existence of both parameters excluded AMI with a 100% specificity. The two groups did not differ with regard to age, first troponin-I value, echocardiographic LV ejection fraction and distribution of hypo/akinetic LV segments. At-admission electrocardiogram (but no clinical, laboratory and echocardiographic features) allows differential diagnosis between TTC and apical-anterior AMI in postmenopausal women. The combination of PR-segment depression and mild (⩽2 mm) ST-segment elevation predicted TTC with greater accuracy than traditional parameters such as localisation of ST-segment elevation and reciprocal ST-segment depression. © The European Society of Cardiology 2015.

  13. Teaching children who use augmentative and alternative communication to ask inverted yes/no questions using aided modeling.

    Science.gov (United States)

    Kent-Walsh, Jennifer; Binger, Cathy; Buchanan, Carolyn

    2015-05-01

    This study investigated the effects of a direct intervention program involving aided modeling and the presentation of contrastive targets on the aided production of inverted yes/no questions and possible generalization to other sentence types by children using augmentative and alternative communication (AAC). A single-case, multiple-probe, experimental design across participants was used to evaluate the effects of the instructional program with 3 children who had motor speech disorders and used AAC (ages 4;10 [years;months], 6;2, and 4;9). The treatment involved aided modeling of treatment and contrastive targets through concentrated modeling and interactive play activities. Direct treatment outcomes were examined by measuring the accuracy of producing inverted yes/no questions and to be declaratives through probes. All 3 participants showed a direct treatment effect, producing a greater number of inverted yes/no questions and to be declaratives within the probes following treatment compared with before treatment. All 3 participants evidenced some generalization to novel sentences. Results provide initial evidence that instruction involving aided modeling with contrastive targets holds promise in targeting specific linguistic rules with children using AAC. Patterns of generalization may depend on participants' specific language deficits and acquisition patterns during intervention.

  14. Takotsubo cardiomyopathy, a two-stage recovery of left ventricular systolic and diastolic function as determined by cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Ahtarovski, Kiril Aleksov; Iversen, Kasper Karmark; Christensen, Thomas Emil

    2014-01-01

    AIMS: Takotsubo cardiomyopathy (TTC) is an entity mimicking acute myocardial infarction, characterized by transient severe systolic heart failure. Echocardiographic studies suggest that diastolic dysfunction is present in TTC at presentation; however, no reports exist regarding the time course...... of left ventricular (LV) recovery. This study describes the recovery of LV systolic and diastolic function in TTC. We hypothesized that, in TTC, there is diastolic dysfunction at admission, and that recovery is delayed compared with systolic function. METHODS AND RESULTS: We enrolled (consecutively 2010......-12) 16 patients (mean age 66, range 39-84 years) diagnosed with TTC and 20 healthy matched controls. We performed cardiac magnetic resonance imaging (CMR) at admission, pre-discharge, and 3-month follow-up. Diastolic function was assessed by LV peak filling rate (LVPFR) and left atrial (LA) emptying...

  15. INVERTER MULTI LEVEL TIPE JEMBATAN SATU FASA TIGA TINGKAT DENGAN MIKROKONTROLER AT89S51

    Directory of Open Access Journals (Sweden)

    A. Warsito A. Warsito

    2012-02-01

    Full Text Available Inverter is a power electronics circuit which is used to convert DC voltage and current to AC voltage andcurrent. In conventional inverter, most commonly used, only has three level voltage, those are +Vdc, -Vdc,and zero. Meanwhile both square inverters and SWPM inverter has big harmonic distortion. In SPWMinverter scheme, high frequency switching must be used to minimize total harmonic distortion (THD. Multilevel inverter is a type of inverter that has more than one level of voltage and current output.The major advantages of multi level inverters are a good voltage waveform, small harmonic dirtortion,switching component operated under low frequency, and it can supply a big power.This paper will discuse the construction of single phase three level multi level inverters, hardware testinginclude output waveform THD, and the comparisson of multilevel inverter with other conventional invertersscheme suc as PWM inverters modulation, and square waveform inverter. Atmel’s AT89S51 microcontrollerused to control switching scheme in this multi level inverter. By this power electronic circuit, it is expected alow cost and reliable multi level inverters prototipe.

  16. PQ Improvement by Moderation of Multi-Level Inverter Controlling Techniques and Intensifying the Performance of DVR

    Directory of Open Access Journals (Sweden)

    Vinay Kumar Awaar

    2015-01-01

    Full Text Available A novel control scheme is proposed for the enhancement of Dynamic Voltage Restorer (DVR performance. In this paper, the moderation of inverter controlling techniques has been adopted to intensify the DVR characteristics and thereby to improve the Power Quality. The proposed model verification has been obtained by simulation of the PWM patterns which provides the better utilization of the device (DVR for the compensation of voltage deviations during voltage sag. Also, it has been shown that Dynamic Voltage Restorer can be worked as a harmonic compensator for the compensation of the current and voltage harmonics. Obtained simulation results verify that the control approach gives very effective regulation and performs excellent voltage compensation by adopting multilevel inverter.

  17. Design, construction and testing of a base driven static inverter ...

    African Journals Online (AJOL)

    Based on the active circuit of a 50Hz astable multivibrator, a base driven static inverter has been designed, constructed and tested. Design is able to convert small amounts of dc current to their amplified ac equivalents. A conversion of 12V dc input to the usual domestic range of 220-240V ac is also derivable from the ...

  18. Resonant inverter supplied Interior Permanent Magnet (IPM) motor ...

    African Journals Online (AJOL)

    In this paper, rotor position in relation to the resonant frequency component current in the stator winding of DC-voltage link resonant inverter supplied Interior Permanent Magnet (IPM) motor has been developed. Six reference frames are used to relate the rotor position angle to the resonant frequency component current ...

  19. Grid-Connected Inverter for Distributed Generation in Microgrid

    DEFF Research Database (Denmark)

    Naderipour, Amirreza; Miveh, Mohammad Reza; Guerrero, Josep M.

    for power generation. DGS units can operate in parallel to the main grid or in a Microgrid (MG) mode. An MG is a discrete energy system consisting of DGSs and loads capable of operating in parallel with, or independently from, the main grid. Meanwhile, Grid-Connected Inverters (GCIs) are typically used...

  20. College Instructors' Experiences Transitioning to Inverted Classroom Instruction

    Science.gov (United States)

    Brown, Glenda Maria

    2017-01-01

    Lecture methods in higher education continue to be the most often used form of lesson delivery, although they seem to be less effective in promoting adult students' learning and engagement. Many higher education instructors have incorporated inverted classroom (IC) methods to increase student engagement and learning. The purpose of this…

  1. Current-type flipped-Γ-source inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Li, Ding; Blaabjerg, Frede

    2012-01-01

    are of interest since they use lesser components. Their winding turns might however become too excessive for higher demanded gains. Avoiding this usual trend, a new family of current-type flipped-Γ-source inverters are proposed, whose common gain is raised by lowering, and not increasing, the winding turns...

  2. Surgical management of palatal placed, inverted, dilacerated and impacted mesiodens.

    Science.gov (United States)

    Nagaveni, Nb; Shashikiran, Nd; Reddy, Vv Subba

    2009-01-01

    Teeth may vary in size, shape and number. Mesiodens is the most commonly occurring supernumerary tooth, usually seen between upper two central incisors which may be impacted or erupted. The present paper describes a rare case of palatal placed, inverted, severely dilacerated and impacted mesiodens which was detected on radiographic examination for some other problem.

  3. Inverted impaction of a mesiodens: a case report.

    Science.gov (United States)

    Atasu, M; Orguneser, A

    1999-01-01

    Dental, radiological, dermatoglyphic and genetic findings of a patient showing inverted impaction of a mesiodens are presented. It is probable that the inversion of the mesiodens was caused by contact of the incisal edge of the crown of the mesiodens by the apex of the root of the erupting right maxillary central incisor tooth.

  4. Multilevel inverter based class D audio amplifier for capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    The reduced semiconductor voltage stress makes the multilevel inverters especially interesting, when driving capacitive transducers for audio applications. A ± 300 V flying capacitor class D audio amplifier driving a 100 nF load in the midrange region of 0.1-3.5 kHz with Total Harmonic Distortion...

  5. 6 5KVA POWER INVERTER DESIGN AND SIMULATION BASED ...

    African Journals Online (AJOL)

    DR. AMINU

    Five (5) kVA power inverter was designed and simulated base on two topologies; Boost converter ... the increasing popularity of alternative power sources, ... Power electronics also provides the industries with effective methods to save energy and improve performance (Sen, 2002). Power electronic devices can be divided ...

  6. Hardness of deriving invertible sequences from finite state machines

    DEFF Research Database (Denmark)

    Hierons, Robert M.; Mousavi, Mohammad Reza; Thomsen, Michael Kirkedal

    2017-01-01

    for state set S′ that contains at most K input sequences; and deciding whether there is a single input sequence that defines invertible sequences that take state set S″ to state set S′. We prove that the first two problems are NP-complete and the third is PSPACE-complete. These results imply that we should...

  7. Multiple-load series resonant inverter for induction cooking ...

    Indian Academy of Sciences (India)

    This paper presents an inverter configuration with two loads by using pulse density modulation control technique. It allows the output power control of each load independently with constant switching frequency and constant duty ratio. The pulse density modulation control technique is obtained using phase on–off control ...

  8. Efficient cascade multiple heterojunction organic solar cells with inverted structure

    Science.gov (United States)

    Guo, Tingting; Li, Mingtao; Qiao, Zhenfang; Yu, Leiming; Zhao, Jianhong; Feng, Nianjun; Shi, Peiguang; Wang, Xiaoyan; Pu, Xiaoyun; Wang, Hai

    2018-05-01

    In this work, we demonstrate an efficient cascade multiple heterojunction organic solar cell with inverted structure. By using two donor materials, poly(3-hexylthiosphene) (P3HT) and titanyl phthalocyanine (TiOPc), as well as two acceptor materials, [6,6]-phenyl C61 butyric acid methyl ester (PCBM) and C60, the cascade multiple heterojunctions of P3HT:PCBM/TiOPc:C60/C60 have been constructed. Applying the optimized inverted configuration of FTO/Zinc Tin Oxide (ZTO)/C60 (30 nm)/TiOPc:C60 (1:1.5, 25 nm)/P3HT:PCBM (1:0.8, 100 nm)/MoO3 (4 nm)/Ag, the considerably enhanced open circuit voltage (VOC) and short circuit current (JSC) can be harvested together, and the power conversion efficiency (PCE) is three times higher than that of the control cell with conventional structure. The significant improvements of the inverted cell are mostly due to the broadened spectral absorption and high efficient multi-interface exciton dissociation in the cascade multiple heterojunctions, indicating that the optimized cascade heterojunctions match the inverted structure well.

  9. A New Green Power Inverter for Fuel Cells

    DEFF Research Database (Denmark)

    Andersen, Gert Karmisholt; Klumpner, Christian; Kjær, Søren Bækhøj

    2002-01-01

    startup. The inverter is controlled as a power factor controller with resistor emulation.Experimental results of converter efficiency, grid performance and fuel cell response are shown for a 1 kW prototype. The proposed converter exhibits a high efficiency in a wide power range (higher than 92......This paper presents a new grid connected inverter for fuel cells. It consists of a two stage power conversion topology. Since the fuel cell operates with a low voltage in a wide voltage range (25 V-45 V) this volt- age must be transformed to around 350-400 V in order to invert this dc power into ac...... power to the grid. The proposed converter consists of an isolated dc-dc converter cascaded with a single phase H-bridge inverter. The dc-dc converter is a current-fed push-pull converter. A new dedicated voltage mode startup procedure has been developed in order to limit the inrush current during...

  10. Case Report - Intussusception caused by an inverted Meckel's ...

    African Journals Online (AJOL)

    The intra operative findings were distention of the small bowel and intussusception of ileus due to an inverted Meckel's diverticulum located 70 cm from the ileocecal valve. 30 cm ischemic loop was identified. A segmental small bowel resection and hand-sewn anastomosis was performed. Histopathology distinguished ...

  11. Cascaded H-bridge multilevel inverter for renewable energy generation

    Science.gov (United States)

    Pandey, Ravikant; Nath Tripathi, Ravi; Hanamoto, Tsuyoshi

    2016-04-01

    In this paper cascaded H-bridge multilevel inverter (CHBMLI) has been investigated for the application of renewable energy generation. Energy sources like solar, wind, hydro, biomass or combination of these can be manipulated to obtain alternative sources for renewable energy generation. These renewable energy sources have different electrical characteristics like DC or AC level so it is challenging to use generated power by connecting to grid or load directly. The renewable energy source require specific power electronics converter as an interface for conditioning generated power .The multilevel inverter can be utilized for renewable energy sources in two different modes, the power generation mode (stand-alone mode), and compensator mode (statcom). The performance of the multilevel inverter has been compared with two level inverter. In power generation mode CHBMLI supplies the active and reactive power required by the different loads. For operation in compensator mode the indirect current control based on synchronous reference frame theory (SRFT) ensures the grid operating in unity power factor and compensate harmonics and reactive power.

  12. Solar-Based Boost Differential Single Phase Inverter | Eya | Nigerian ...

    African Journals Online (AJOL)

    ... current concurrently and finally, it is portable. This research also shows the disparity between the simulated results of open loop and closed loop of boost differential inverter systems. The dc power source is photovoltaic cell. The maximum power point tracker is in-cooperated in capturing the maximum power from the sun.

  13. Reversible degradation of inverted organic solar cells by concentrated sunlight

    DEFF Research Database (Denmark)

    Tromholt, Thomas; Manor, Assaf; Katz, Eugene A

    2011-01-01

    Concentrated sunlight was used to study the performance response of inverted P3HT:PCBM organic solar cells after exposure to high intensity sunlight. Correlations of efficiency as a function of solar intensity were established in the range of 0.5–15 suns at three different stages: for a pristine...

  14. Recurrent inverted papilloma of paranasal sinus presenting as acute proptosis.

    Science.gov (United States)

    Prabhakar, S K; Bharathi, M B; Singhal, Anuj Kumar

    2016-01-01

    Objective. To describe the course of events that followed from the time of the diagnosis to the management of a rare case of recurrent inverted papilloma presenting as an acute proptosis. Methods. A seventy-year-old diabetic female patient presented with a painful left eye proptosis for 15 days. She had a history of resection of inverted papilloma of paranasal sinus followed by radiotherapy for eight years before. The examination revealed a 23 mm proptosis, with restricted ocular movements, corneal oedema, funnel shaped anterior chamber, and total retinal detachment with a complete visual loss. The lobulated fixed hard mass was palpable circumferentially but more in the inferior orbital compartment. The transconjunctival incisional biopsy showed features of highly undifferentiated cytology. The lid sparing exenteration was done under general anesthesia with cosmetic reconstruction. Results. Immunohistochemistry of exenterated mass was doubtfully suggestive of a small cell tumor. However, histopathology confirmed features of rhabdomyosarcoma. Conclusion. The present case study revealed rhabdomyosarcoma cytology presenting as an association-inverted papilloma. Abbreviations : IP = Inverted papilloma, PNS = Paranasal sinus, SCC = Squamous cell carcinoma, IOP = Intraocular pressure, CT = Computed tomography.

  15. Performance Improvement of Single Phase Inverter using SPWM

    Science.gov (United States)

    Gavaskar Reddy, B., Dr; Maheswari, L., Dr; Ganeswari Kale, Adi

    2017-08-01

    This paper concentrates on modelling and simulation of single phase inverter as a frequency changer modulated by Pulse Width Modulation (PWM). An inverter is a circuit that converts DC sources to AC sources. Pulse Width Modulation is a method that utilization as an approach to abatement add up to harmonic distortion in inverter circuit. The model is executed utilizing MATLAB/Simulink software with the SimPower System Block Set in light of PC simulation. PC simulation assumes an imperative part in the plan, investigation, and assessment of force electronic converter and their controller. MATLAB is a successful instrument to examine a PWM inverter. Preferences of utilizing MATLAB are the accompanying: Faster reaction, accessibility of different simulation devices and utilitarian squares and the nonappearance of joining issues. Safe-replacement methodology need be actualized is to explain exchanging Transients. In this way, Insulated Gate Bipolar Transistor (IGBT) is use as exchanging gadgets. IGBT is ideal since it is anything but difficult to control and low misfortunes. The outcome from Simulink was checked utilizing MATLAB simulation.

  16. Charging capacitors of multilevel inverter from dc intermediate circuit

    Czech Academy of Sciences Publication Activity Database

    Bejvl, Martin

    2011-01-01

    Roč. 56, č. 2 (2011), s. 159-170 ISSN 0001-7043 R&D Projects: GA MPO FT-TA4/077 Institutional research plan: CEZ:AV0Z20570509 Keywords : electric drive * multilevel inverter * modulation and demodulation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  17. Energy-efficient adjustable speed double inverter-fed woundrotor ...

    African Journals Online (AJOL)

    Energy-efficient adjustable speed double inverter-fed woundrotor induction motor drive. ... of this type of electric drive over others types of AC drives for many technological processes. Keywords: power, double-fed wound-rotor induction motor drive, steel and total losses, efficiency, energy-efficient control algorithm ...

  18. Evaluation of Three-Phase Transformerless Photovoltaic Inverter Topologies

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper analyzes and compares three transformerless photovoltaic inverter topologies for three-phase grid connection with the main focus on the safety issues that result from the lack of galvanic isolation. A common-mode model, valid at frequencies lower than 50 kHz, is adopted to study...

  19. High voltage power supply with modular series resonant inverters

    Science.gov (United States)

    Dreifuerst, Gary R.; Merritt, Bernard T.

    1995-01-01

    A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

  20. Extended topologies of tapped-inductor Z-source inverters

    DEFF Research Database (Denmark)

    Zhu, Miao; Li, Ding; Gao, Feng

    2011-01-01

    In this paper, two distinct types of tapped-inductor Z-source impedance networks are proposed for implementing high performance voltage-type inverters topologies with strong voltage boost inversion abilities and less components' stresses. All proposed topologies can in principle be unified...

  1. LCCT-derived three-level three-phase inverters

    DEFF Research Database (Denmark)

    Shults, Tatiana; Husev, Oleksandr; Blaabjerg, Frede

    2017-01-01

    Solutions for a family of the novel three-level neutral-point-clamped (NPC) inductor-capacitor-capacitor-transformer (LCCT)-derived three-phase inverters are described and compared. Component design guidelines and steady state analysis, current and voltage waveforms are given. The authors...... input voltage source and continuous input current are presented. The main advantages and design requirements are discussed...

  2. Hybrid Modulation Scheme for Cascaded H-Bridge Inverter Cells ...

    African Journals Online (AJOL)

    This work proposes a switching technique for cascaded H-Bridge (CHB) cells. Single carrier Sinusoidal PWM (SCSPWM) scheme is employed in the generation of the gating signals. A sequential switching and base PWM circulation schemes are presented for this fundamental cascaded multilevel inverter topology.

  3. Localized chaoticity in two linearly coupled inverted double-well ...

    African Journals Online (AJOL)

    Two linearly coupled inverted double-well oscillators for a fixed energy and varying coupling strength were studied. The dynamics yielded a chaotic system in which the Poincare surface was characterised by two non-mixing regions, one of regular motion and the other region that became chaotic as the coupling increased.

  4. Blitzkrieg inverted or the Retiarius's net | Heitman | Scientia Militaria ...

    African Journals Online (AJOL)

    Scientia Militaria: South African Journal of Military Studies. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 8, No 1 (1978) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Blitzkrieg inverted or the ...

  5. Efficient eco-friendly inverted quantum dot sensitized solar cells.

    Science.gov (United States)

    Park, Jinhyung; Sajjad, Muhammad T; Jouneau, Pierre-Henri; Ruseckas, Arvydas; Faure-Vincent, Jérôme; Samuel, Ifor D W; Reiss, Peter; Aldakov, Dmitry

    2016-01-21

    Recent progress in quantum dot (QD) sensitized solar cells has demonstrated the possibility of low-cost and efficient photovoltaics. However, the standard device structure based on n-type materials often suffers from slow hole injection rate, which may lead to unbalanced charge transport. We have fabricated efficient p-type (inverted) QD sensitized cells, which combine the advantages of conventional QD cells with p-type dye sensitized configurations. Moreover, p-type QD sensitized cells can be used in highly promising tandem configurations with n-type ones. QDs without toxic Cd and Pb elements and with improved absorption and stability were successfully deposited onto mesoporous NiO electrode showing good coverage and penetration according to morphological analysis. Detailed photophysical charge transfer studies showed that high hole injection rates (10 8 s -1 ) observed in such systems are comparable with electron injection in conventional n-type QD assemblies. Inverted solar cells fabricated with various QDs demonstrate excellent power conversion efficiencies of up to 1.25%, which is 4 times higher than the best values for previous inverted QD sensitized cells. Attempts to passivate the surface of the QDs show that traditional methods of reduction of recombination in the QD sensitized cells are not applicable to the inverted architectures.

  6. Study of a centrifugal pump, asynchronous motor and inverter, using ...

    African Journals Online (AJOL)

    HILS) concept to the study of a three-phase inverter, asynchronous motor and centrifugal pump. It presents the realization of the rectangular control using a micro controller (ATMEGA 168). The signals generated by the micro controller have been ...

  7. Modified impedance source inverter for power conditioning system

    Indian Academy of Sciences (India)

    DC link voltage boost, reduced total harmonic distortion of output current and voltage, better voltage gain and wide range of output voltage controlcan be achieved easily with improved power quality. Experimental set-up of the modified impedance source inverter with Field Programmable Gate Array (FPGA) controller has ...

  8. Impedance estimation of photovoltaic modules for inverter start-up ...

    Indian Academy of Sciences (India)

    Starting-up of photovoltaic (PV) inverters involves pre-charging of the input dc bus capacitance. Ideally, direct pre-charging of this capacitance from the PV modules is possible as the PV modules are current limited. Practically, the parasitic elements of the system such as the PV module capacitance, effective wire inductance ...

  9. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature). The mission profile is translated to device thermal loading, which is used for lifetime prediction. Compar¬ison results reveal the lifetime mismatches among the power switching...

  10. Static balancing of an inverted pendulum with prestressed torsion bars

    NARCIS (Netherlands)

    Radaelli, G.; Buskermolen, R; Barents, R; Herder, J.L.

    2017-01-01

    This paper presents a method for the design of a statically balanced inverted pendulum. The non-linear moment-rotation characteristic of the pendulum's weight is approximated by a piecewise linear characteristic. Each transition is realized by engaging or disengaging one or more torsion bars, by

  11. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  12. A single phase photovoltaic inverter control for grid connected system

    Indian Academy of Sciences (India)

    This paper presents a control scheme for single phase grid connected photovoltaic (PV) system operating under both grid connected and isolated grid mode. The control techniques include voltage and current control of grid-tie PV inverter. During grid connected mode, grid controls the amplitude and frequency of the PV ...

  13. Thermal ageing analysis and lifetime prediction of IGBT inverter for ...

    African Journals Online (AJOL)

    The option of either choosing design configuration according to using the device during the entire lifetime or half of the lifetime of the solar panel was the major decision. The research findings would contribute to better adaptation of IGBT inverter-solar panel for grid electricity connectivity in relation to the replacement of the ...

  14. Simple improvements of a simple solution for inverting resolution

    NARCIS (Netherlands)

    J.C. Bioch (Cor); P.R.J. van der Laag

    1991-01-01

    textabstractIn this paper we address some simple improvements of the algorithm of Rouveirol and Puget [1989] for inverting resolution. Their approach is based on automatic change of representation called flattening and unflattening of clauses in a logic program. This enables a simple implementation

  15. A single phase photovoltaic inverter control for grid connected system

    Indian Academy of Sciences (India)

    tracking (MPPT) controller is used which enables the maximum power extraction under varying irradiation and temperature conditions. The validity of the proposed system is verified through simulation as well as hardware implementation. Keywords. Current controller; MPPT; photovoltaic; PLL; PV inverter; voltage controller.

  16. Multiple-load series resonant inverter for induction cooking ...

    Indian Academy of Sciences (India)

    P Sharath Kumar

    Induction cooking; multiple load; series resonant inverter; ZVS; pulse density modulation control. 1. Introduction. Induction heating (IH) method is a far better approach than conventional methods. In conventional methods, heat is transferred from a heat source to load by conduction or radi- ation. In IH, heat is developed ...

  17. Power losses in bilayer inverted small molecule organic solar cells

    KAUST Repository

    Trinh, Cong

    2012-01-01

    Inverted bilayer organic solar cells using copper phthalocyanine (CuPc) as a donor and C60 as an acceptor with the structure: glass/indium tin oxide (ITO)/ZnO/C60/CuPc/MoO3/Al, in which the zinc oxide (ZnO) was deposited by atomic layer deposition, are compared with a conventional device: glass/ITO/CuPc/C60/bathocuproine/Al. These inverted and conventional devices give short circuit currents of 3.7 and 4.8 mA/cm 2, respectively. However, the inverted device gives a reduced photoresponse from the CuPc donor compared to that of the conventional device. Optical field models show that the arrangement of organic layers in the inverted devices leads to lower absorption of long wavelengths by the CuPc donor; the low energy portion of the spectrum is concentrated near the metal oxide electrode in both devices. © 2012 American Institute of Physics.

  18. Controlling An Inverter-Driven Three-Phase Motor

    Science.gov (United States)

    Dolland, C.

    1984-01-01

    Control system for three-phase permanent-magnet motor driven by linecommutated inverter uses signals generated by integrating back emf of each phase of motor. High-pass filter network eliminates low-frequency components from control loop while maintaining desired power factor.

  19. Regenerative Snubber For GTO-Commutated SCR Inverter

    Science.gov (United States)

    Rippel, Wally E.; Edwards, Dean B.

    1992-01-01

    Proposed regenerative snubbing circuit substituted for dissipative snubbing circuit in inverter based on silicon controlled rectifiers (SCR's) commutated by gate-turn-off thyristor (GTO). Intended to reduce loss of power that occurs in dissipative snubber. Principal criteria in design: low cost, simplicity, and reliability.

  20. Monolithically Integrated Flexible Black Phosphorus Complementary Inverter Circuits.

    Science.gov (United States)

    Liu, Yuanda; Ang, Kah-Wee

    2017-07-25

    Two-dimensional (2D) inverters are a fundamental building block for flexible logic circuits which have previously been realized by heterogeneously wiring transistors with two discrete channel materials. Here, we demonstrate a monolithically integrated complementary inverter made using a homogeneous black phosphorus (BP) nanosheet on flexible substrates. The digital logic inverter circuit is demonstrated via effective threshold voltage tuning within a single BP material, which offers both electron and hole dominated conducting channels with nearly symmetric pinch-off and current saturation. Controllable electron concentration is achieved by accurately modulating the aluminum (Al) donor doping, which realizes BP n-FET with a room-temperature on/off ratio >10 3 . Simultaneously, work function engineering is employed to obtain a low Schottky barrier contact electrode that facilities hole injection, thus enhancing the current density of the BP p-FET by 9.4 times. The flexible inverter circuit shows a clear digital logic voltage inversion operation along with a larger-than-unity direct current voltage gain, while exhibits alternating current dynamic signal switching at a record high frequency up to 100 kHz and remarkable electrical stability upon mechanical bending with a radii as small as 4 mm. Our study demonstrates a practical monolithic integration strategy for achieving functional logic circuits on one material platform, paving the way for future high-density flexible electronic applications.

  1. Optimization of Nanowire-Resistance Load Logic Inverter.

    Science.gov (United States)

    Hashim, Yasir; Sidek, Othman

    2015-09-01

    This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.

  2. Multilevel inverter based class D audio amplifier for capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    The reduced semiconductor voltage stress makes the multilevel inverters especially interesting, when driving capacitive transducers for audio applications. A ± 300 V flying capacitor class D audio amplifier driving a 100 nF load in the midrange region of 0.1-3.5 kHz with Total Harmonic Distortion...... plus Noise (THD+N) belo w1%is presented....

  3. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented...

  4. Sine-wave three phase resonance inverter for operation of ...

    African Journals Online (AJOL)

    This paper proposes a high performance single-stage three phase inverter topology for the autonomous operation of renewable energy systems. The proposed configuration can boost the low voltage of renewable energy systems such as photo voltaic systems, fuel cells, and etc can also convert the output dc power, into ...

  5. Mathematical Model of Thyristor Inverter Including a Series-parallel Resonant Circuit

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with theaid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  6. Mathematical model of thyristor inverter including a series-parallel resonant circuit

    OpenAIRE

    Luft, M.; Szychta, E.

    2008-01-01

    The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with the aid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  7. Mathematical Model of Thyristor Inverter Including a Series-parallel Resonant Circuit

    OpenAIRE

    Miroslaw Luft; Elzbieta Szychta

    2008-01-01

    The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with theaid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  8. Comparison of Solid State Inverters for AC Induction Motor Traction Propulsion Systems

    Science.gov (United States)

    1980-12-01

    This report is one of a series concerned with the application of ac machines as traction motors for railroad motive power. It presents results of a laboratory evaluation and computer analysis of different inverter systems. Three inverter systems, sin...

  9. Comparison between three phase three and five level of flying capacitor multilevel inverter

    Science.gov (United States)

    Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Tzen, Bryon Sim Phin

    2017-09-01

    Multilevel inverter is increasingly being used in medium and high power application as conventional inverter have limited power hold and high total harmonics distortion. At present, there is a lot of literature regarding the topology and switching technique for multilevel inverter. The three common types of multilevel inverter are Diode Clamp Multilevel Inverter (DCMI), Cascaded Multilevel Inverter (CMI) and Flying Capacitor Multilevel Inverter (FCMI). This paper proposed the Three Phase Flying Capacitor Multilevel Inverter (FCMI) with Sinusoidal Pulse Width Modulation (SPWM) switching technique. This paper analysed the performance of FCMI and its characteristics based on parameters such as output phase voltage waveform and the total harmonics distortion (THD). The performance was accessed using Matlab/Simulink software. The result obtained shows that with higher number of levels for FCMI, the output THD was lowered due to near sinusoidal output waveform.

  10. Active control of flying capacitor currents in multilevel voltage-source inverters

    Czech Academy of Sciences Publication Activity Database

    Kokeš, Petr; Semerád, Radko

    2013-01-01

    Roč. 58, č. 4 (2013), s. 393-410 ISSN 0001-7043 Institutional support: RVO:61388998 Keywords : voltage source inverter (VSI) * multilevel inverter * flying capacitor Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  11. Remote Control of an Inverted Pendulum System for Intelligent Control Education

    Directory of Open Access Journals (Sweden)

    Seul Jung

    2011-08-01

    Full Text Available This paper presents a remote control task of an inverted pendulum system for intelligent control education. The inverted pendulum moving on the guided rail is required to maintain balancing while it follows the desired trajectory commanded remotely by a joystick operated by a user. Position commands for the inverted pendulum system are given by a joystick through the network. The inverted pendulum system is controlled by a neural network control method. The corresponding control results are confirmed through experimental studies.

  12. MODELLING AND SIMULATION OF HIGH FREQUENCY INVERTER FOR INDUCTION HEATING APPLICATION

    OpenAIRE

    SACHIN S. BANKAR; Dr. PRASAD M. JOSHI

    2016-01-01

    This paper presents modelling and simulation of high frequency inverter for induction heating applications. Induction heating has advantages like higher efficiency, controlled heating, safety and pollution free therefore this technology is used in industrial, domestic and medical applications. The high frequency full bridge inverter is used for induction heating, also MOSFET is used as a switching device for inverter and the control strategy used for inverter is Bipolar PWM control. The size ...

  13. Simulation model of harmonics reduction technique using shunt active filter by cascade multilevel inverter method

    Science.gov (United States)

    Andreh, Angga Muhamad; Subiyanto, Sunardiyo, Said

    2017-01-01

    Development of non-linear loading in the application of industry and distribution system and also harmonic compensation becomes important. Harmonic pollution is an urgent problem in increasing power quality. The main contribution of the study is the modeling approach used to design a shunt active filter and the application of the cascade multilevel inverter topology to improve the power quality of electrical energy. In this study, shunt active filter was aimed to eliminate dominant harmonic component by injecting opposite currents with the harmonic component system. The active filter was designed by shunt configuration with cascaded multilevel inverter method controlled by PID controller and SPWM. With this shunt active filter, the harmonic current can be reduced so that the current wave pattern of the source is approximately sinusoidal. Design and simulation were conducted by using Power Simulator (PSIM) software. Shunt active filter performance experiment was conducted on the IEEE four bus test system. The result of shunt active filter installation on the system (IEEE four bus) could reduce THD current from 28.68% to 3.09%. With this result, the active filter can be applied as an effective method to reduce harmonics.

  14. Electrical power inverter having a phase modulated, twin-inverter, high frequency link and an energy storage module

    Science.gov (United States)

    Pitel, Ira J.

    1987-02-03

    The present invention provides an electrical power inverter method and apparatus, which includes a high frequency link, for converting DC power into AC power. Generally stated, the apparatus includes a first high frequency module which produces an AC voltage at a first output frequency, and a second high frequency inverter module which produces an AC voltage at a second output frequency that is substantially the same as the first output frequency. The second AC voltage is out of phase with the first AC voltage by a selected angular phase displacement. A mixer mixes the first and second output voltages to produce a high frequency carrier which has a selected base frequency impressed on the sidebands thereof. A rectifier rectifies the carrier, and a filter filters the rectified carrier. An output inverter inverts the filtered carrier to produce an AC line voltage at the selected base frequency. A phase modulator adjusts the relative angular phase displacement between the outputs of the first and second high frequency modules to control the base frequency and magnitude of the AC line voltage.

  15. Clustered PV Inverters in LV Networks: An Overview of Impacts and Comparison of Voltage Control Strategies

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2009-01-01

    High penetration of photovoltaic (PV) inverters in low voltage (LV) distribution network challenges the voltage stability due to interaction between multiple inverters and grid. As the main objective is to provide more power injection from VSC-based PV inverters, grid stability, reliability and p...

  16. 77 FR 27547 - Federal Acquisition Regulation; Prohibition on Contracting With Inverted Domestic Corporations

    Science.gov (United States)

    2012-05-10

    ... 9000-AM22 Federal Acquisition Regulation; Prohibition on Contracting With Inverted Domestic..., the prohibition against contracting with any inverted domestic corporation, as defined at section 835... contracting with inverted domestic corporations, the prohibition does not apply when using Fiscal Year 2012...

  17. Variable-frequency inverter controls torque, speed, and braking in ac induction motors

    Science.gov (United States)

    Nola, F. J.

    1974-01-01

    Dc to ac inverter provides optimum frequency and voltage to ac induction motor, in response to different motor-load and speed requirements. Inverter varies slip frequency of motor in proportion to required torque. Inverter protects motor from high current surges, controls negative slip to apply braking, and returns energy stored in momentum of load to dc power source.

  18. LC-filter Resonance Cancellation with DPWM Inverters in Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Vadstrup, Casper; Wang, Xiongfei; Blaabjerg, Frede

    2015-01-01

    in the inverter and filter. Instead of abruptly clamp in one of the inverter legs and cause resonance in the filter. This method will charge or discharge the filter capacitor before clamping, this way the capacitor current is zero, and the capacitor voltage is equal to the average inverter voltage. Thereby...

  19. Advanced Inverter Functions to Support High Levels of Distributed Solar: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    This paper explains how advanced inverter functions (sometimes called 'smart inverters') contribute to the integration of high levels of solar PV generation onto the electrical grid and covers the contributions of advanced functions to maintaining grid stability. Policy and regulatory considerations associated with the deployment of advanced inverter functions are also introduced.

  20. Stability analysis of grid inverter LCL-filter resonance in wind or photovoltaic parks

    DEFF Research Database (Denmark)

    Arcuri, S.; Liserre, M.; Ricchiuto, D.

    2011-01-01

    Typically the resonance problems related to the use of LCL-filters in grid connected inverters are analyzed assuming the operation of a single inverter. Wind and photovoltaic parks may experience propagation of resonance from a poorly damped inverter to other systems connected in parallel...

  1. Novel Family of modified qZS buck-boost multilevel inverters with reduced switch count

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Strzelecki, Ryszard; Blaabjerg, Frede

    2015-01-01

    This paper describes a novel family of modified quasi-Z-source buck-boost multilevel inverters with reduced switch count. The inverters are derived by means of the modified inverter configuration with quasi-Z-source networks. The main benefits of the proposed solutions lie in the increased amount...

  2. Design and comparison of three-level three-phase T-source inverters

    DEFF Research Database (Denmark)

    Shults, T.; Husev, Oleksandr; Blaabjerg, Frede

    2015-01-01

    This paper presents guidelines for component design of recently proposed topologies of the three-level three-phase T-source inverters. Two different topologies are considered: T-source inverters with discontinuous input current and T-source inverters with continuous input current. Steady state...

  3. Large-Signal Lyapunov-Based Stability Analysis of DC/AC Inverters and Inverter-Based Microgrids

    Science.gov (United States)

    Kabalan, Mahmoud

    Microgrid stability studies have been largely based on small-signal linearization techniques. However, the validity and magnitude of the linearization domain is limited to small perturbations. Thus, there is a need to examine microgrids with large-signal nonlinear techniques to fully understand and examine their stability. Large-signal stability analysis can be accomplished by Lyapunov-based mathematical methods. These Lyapunov methods estimate the domain of asymptotic stability of the studied system. A survey of Lyapunov-based large-signal stability studies showed that few large-signal studies have been completed on either individual systems (dc/ac inverters, dc/dc rectifiers, etc.) or microgrids. The research presented in this thesis addresses the large-signal stability of droop-controlled dc/ac inverters and inverter-based microgrids. Dc/ac power electronic inverters allow microgrids to be technically feasible. Thus, as a prelude to examining the stability of microgrids, the research presented in Chapter 3 analyzes the stability of inverters. First, the 13 th order large-signal nonlinear model of a droop-controlled dc/ac inverter connected to an infinite bus is presented. The singular perturbation method is used to decompose the nonlinear model into 11th, 9th, 7th, 5th, 3rd and 1st order models. Each model ignores certain control or structural components of the full order model. The aim of the study is to understand the accuracy and validity of the reduced order models in replicating the performance of the full order nonlinear model. The performance of each model is studied in three different areas: time domain simulations, Lyapunov's indirect method and domain of attraction estimation. The work aims to present the best model to use in each of the three domains of study. Results show that certain reduced order models are capable of accurately reproducing the performance of the full order model while others can be used to gain insights into those three areas of

  4. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot......-through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase...

  5. Techniques for the optimal design of photovoltaic inverters interconnected with the electric grid

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    The DC/AC inverters are the key elements of grid-connected PV energy production systems. In this paper, a new technique for the optimal design of the power section and output filter of a full-bridge, grid-connected PV inverter, is proposed. The objective function which is minimized during...... the Genetic Algorithm-based optimization procedure is the PV inverter Levelized Cost Of the Electricity generated (LCOE). The proposed method has been applied for the optimal design of PV inverters installed at various sites in Europe. The simulation results indicate that the optimal values of the PV inverter...

  6. Design optimization of transformerless grid-connected PV inverters including reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost...... to the non-optimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  7. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    -through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase......This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot...

  8. Efficiency analysis on a two-level three-phase quasi-soft-switching inverter

    DEFF Research Database (Denmark)

    Geng, Pan; Wu, Weimin; Huang, Min

    2013-01-01

    When designing an inverter, an engineer often needs to select and predict the efficiency beforehand. For the standard inverters, plenty of researches are analyzing the power losses and also many software tools are being used for efficiency calculation. In this paper, the efficiency calculation...... for non-conventional inverters with special shoot-through state is introduced and illustrated through the analysis on a special two-level three-phase quasi-soft-switching inverter. Efficiency comparison between the classical two-stage two-level three-phase inverter and the two-level three-phase quasi-soft...

  9. Experimental Analysis of Variable Capacity Heat Pump Systems equipped with a liquid-cooled frequency inverter

    OpenAIRE

    Ebraheem, Thair

    2013-01-01

    Using an inverter-driven compressor in variable capacity heat pump systems has a main drawback, which is the extra loss in the inverter. The present experimental study aims to recover the inverter losses by using brine-cooled and water-cooled inverters, thereby improving the total efficiency of the heat pump system. In order to achieve this goal, a test rig with the air-cooled, water-cooled and brine-cooled inverters is designed and built, and a comparative analysis of the recovered heat, inv...

  10. A new type of single-phase five-level inverter

    Science.gov (United States)

    Xu, Zhi; Li, Shengnan; Qin, Risheng; Zhao, Yanhang

    2017-11-01

    At present, Neutral Point Clamped (NPC) multilevel inverter is widely applied in new energy field. However, it has some disadvantages including low utilization rate of direct current (DC) voltage source and the unbalance of neutral potential. Therefore, a new single-phase five level inverter is proposed in this paper. It has two stage structure, the former stage is equivalent to three level DC/DC converter, and the back stage uses H bridge to realize inverter. Compared with the original central clamp type inverter, the new five level inverter can improve the utilization of DC voltage, and realize the neutral point potential balance with hysteresis comparator.

  11. Predictive Current Control of Grid-tied Cascade H-bridge Inverter

    OpenAIRE

    Pástor, Marek; Dudrik, Jaroslav

    2013-01-01

    This paper presents a grid-tied cascade H-bridge inverter with predictive current control technique. The proposed 15-level cascade inverter consists of three H-bridge inverters with separated DC sources. At the output of the cascade inverter an L filter is used as a grid filter. The cascade inverter is controlled by the mean of RT-Lab. The predictive current regulator and one-phase synchronous reference frame PLL are designed with help of Rapid Control Prototyping. The proposed control method...

  12. Role of additional PCBM layer between ZnO and photoactive layers in inverted bulk-heterojunction solar cells.

    Science.gov (United States)

    Cho, Shinuk; Kim, Kwang-Dae; Heo, Jinhee; Lee, Joo Yul; Cha, Gihoon; Seo, Bo Yeol; Kim, Young Dok; Kim, Yong Soo; Choi, Si-young; Lim, Dong Chan

    2014-03-07

    In order to induce greater light absorption, nano-patterning is often applied to the metal-oxide buffer layer in inverted bulk-heterojunction(BHJ) solar cells. However, current homogeneity was significantly disturbed at the interface, leading to an efficiency that was not fully optimized. In this work, an additional PC61BM layer was inserted between the ZnO ripple and the photoactive layer to enhance the electron extraction. The insertion of additional PC61BM layer provided substantial advantages in the operation of inverted BHJ solar cells; specifically, it enhanced current homogeneity and lowered accumulation and trapping of photogenerated charges at the ZnO interface. Inclusion of the additional PC61BM layer led to effective quenching of electron-hole recombination by a reduction in the number of accumulated charges at the surface of ZnO ripples. This resulted in a 16% increase in the efficiency of inverted BHJ solar cells to 7.7%, compared to solar cells without the additional PC61BM layer.

  13. Method for detecting an open-switch fault in a grid-connected NPC inverter system

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Jeong, Hae-Gwang; Lee, Kyo-Beum

    2012-01-01

    This paper proposes a fault-detection method for an open-switch fault in the switches of grid-connected neutral-point-clamped inverter systems. The proposed method can not only detect the fault condition but also identify the location of the faulty switch. In the proposed method, which is designed...... by incorporating a simple switching control in the conventional method, the fault condition is detected on the basis of the radius of the Concordia current pattern, and the location of the faulty switch can be identified. By using the proposed method, it is possible to detect the open-switch fault and identify...... the faulty switch within two fundamental periods, without using additional sensors or performing complex calculations. Simulations and experiments are carried out to confirm the reliability of the proposed fault-detection method....

  14. Inverted cones grating for flexible metafilter at optical and infrared frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Brückner, Jean-Baptiste; Le Rouzo, Judikaël; Escoubas, Ludovic [Aix-Marseille Université, IM2NP, CNRS-UMR 7334, Domaine Universitaire de Saint-Jérôme, Service 231, 13397 Marseille Cedex 20 (France); Brissonneau, Vincent; Dubarry, Christophe [CEA-LITEN DTNM, 17 Avenue des Martyrs, 38054 Grenoble cedex 9 (France); Ferchichi, Abdelkerim; Gourgon, Cécile [LTM CNRS, Laboratoire des Technologies de la Microélectronique 17 Avenue des Martyrs, 38054 Grenoble cedex 9 (France); Berginc, Gérard [Thales Optronique S.A., 2 Avenue Gay Lussac, 78990 Elancourt (France)

    2014-02-24

    By combining the antireflective properties from gradual changes in the effective refractive index and cavity coupling from cone gratings and the efficient optical behavior of a tungsten film, a flexible filter showing very broad antireflective properties from the visible to short wavelength infrared region and, simultaneously, a mirror-like behavior in the mid-infrared wavelength region and long-infrared wavelength region has been conceived. Nanoimprint technology has permitted the replication of inverted cone patterns on a large scale on a flexible polymer, afterwards coated with a thin tungsten film. This optical metafilter is of great interest in the stealth domain where optical signature reduction from the optical to short wavelength infrared region is an important matter. As it also acts as selective thermal emitter offering a good solar-absorption/infrared-emissivity ratio, interests are found as well for solar heating applications.

  15. Inverted cones grating for flexible metafilter at optical and infrared frequencies

    Science.gov (United States)

    Brückner, Jean-Baptiste; Brissonneau, Vincent; Le Rouzo, Judikaël; Ferchichi, Abdelkerim; Gourgon, Cécile; Dubarry, Christophe; Berginc, Gérard; Escoubas, Ludovic

    2014-02-01

    By combining the antireflective properties from gradual changes in the effective refractive index and cavity coupling from cone gratings and the efficient optical behavior of a tungsten film, a flexible filter showing very broad antireflective properties from the visible to short wavelength infrared region and, simultaneously, a mirror-like behavior in the mid-infrared wavelength region and long-infrared wavelength region has been conceived. Nanoimprint technology has permitted the replication of inverted cone patterns on a large scale on a flexible polymer, afterwards coated with a thin tungsten film. This optical metafilter is of great interest in the stealth domain where optical signature reduction from the optical to short wavelength infrared region is an important matter. As it also acts as selective thermal emitter offering a good solar-absorption/infrared-emissivity ratio, interests are found as well for solar heating applications.

  16. Extremum Seeking Control of Smart Inverters for VAR Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Daniel; Negrete-Pincetic, Matias; Stewart, Emma; Auslander, David, M; Callaway, Duncan

    2015-09-04

    Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand information confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.

  17. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter........ The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  18. Current control loop of 3-phase grid-connected inverter

    International Nuclear Information System (INIS)

    Jabbar, A F; Mansor, M

    2013-01-01

    This paper presents a comparative study of current control loop in 3-phase inverter which is used to control the active and reactive output power. Generally, current control loop, power control loop and phase lock-loop are the conventional parameters that can be found in an inverter system controlled by the conventional linear control type, for instance proportional (P), integral (I) and derivative (D). If the grid remains stable throughout the day, PID control can be use. However variation of magnitude, frequency, voltage dips, transient, and other related power quality issues occur in a 3-phase grid often affects the control loop. This paper aims to provide an overall review on the available current control techniques used in grid connected system.

  19. The management of sinonasal inverted papilloma: our experience.

    Science.gov (United States)

    Terzakis, Georgios; Vlachou, Stamatia; Kyrmizakis, Dionysios; Helidonis, Emmanuel

    2002-03-01

    The inverted papilloma of the nose and paranasal sinuses is a controversial disease. It invades surrounded structures, shows a high recurrence rate after surgical excision and may coexist with squamous cell carcinoma. The use of the optimal surgical approach and technique is of the utmost importance, as it is related to the possibility of recurrence. In cases of tumors of limited size a conservative local excision is sufficient, while, in larger tumors filling the nasal cavity and the paranasal sinuses a more aggressive strategy is needed, such as a medial maxillectomy after lateral rhinotomy. In this paper we present our experience from treating 42 sinonasal inverted papillomas, using a surgical technique which is based on the conservation of as much part of the healthy lateral nasal wall as possible. This modified medial maxillectomy allows us to create a limited in size and normally functioning nasal cavity, thus minimizing the disadvantages of the classical medial maxillectomy without jeopardizing the safety of the operation.

  20. Modular Synthetic Inverters from Zinc Finger Proteins and Small RNAs.

    Directory of Open Access Journals (Sweden)

    Justin Hsia

    Full Text Available Synthetic zinc finger proteins (ZFPs can be created to target promoter DNA sequences, repressing transcription. The binding of small RNA (sRNA to ZFP mRNA creates an ultrasensitive response to generate higher effective Hill coefficients. Here we combined three "off the shelf" ZFPs and three sRNAs to create new modular inverters in E. coli and quantify their behavior using induction fold. We found a general ordering of the effects of the ZFPs and sRNAs on induction fold that mostly held true when combining these parts. We then attempted to construct a ring oscillator using our new inverters. Our chosen parts performed insufficiently to create oscillations, but we include future directions for improvement upon our work presented here.

  1. Inverter-based successive approximation capacitance-to-digital converter

    KAUST Repository

    Omran, Hesham

    2017-03-23

    An energy-efficient capacitance-to-digital converter (CDC) is provided that utilizes a capacitance-domain successive approximation (SAR) technique. Unlike SAR analog- to-digital converters (ADCs), analysis shows that for SAR CDCs, the comparator offset voltage will result in signal-dependent and parasitic-dependent conversion errors, which necessitates an op-amp-based implementation. The inverter-based SAR CDC contemplated herein provides robust, energy-efficient, and fast operation. The inverter- based SAR CDC may include a hybrid coarse-fine programmable capacitor array. The design of example embodiments is insensitive to analog references, and thus achieves very low temperature sensitivity without the need for calibration. Moreover, this design achieves improved energy efficiency.

  2. Hybrid zero-voltage switching (ZVS) control for power inverters

    Energy Technology Data Exchange (ETDEWEB)

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  3. Improved Droop Control Strategy for Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Abusara, Mohammad; Sharkh, Suleiman; Guerrero, Josep M.

    2015-01-01

    An improved control strategy for grid-connected inverters within microgrids is presented in this paper. The strategy is based on the classical P-ω and Q-V droop method. The improvement in the proposed control strategy is twofold: Firstly, the transient response of the droop controller is improved...... by replacing the traditional method of measuring average power, which is based on using a first order low pass filter, by a real time integration filter. This is shown to reduce the imported transient energy when connecting to the grid. Secondly, the steady state output current quality is improved by utilising...... a virtual inductance, which is shown to reject grid voltage harmonics disturbance and thus improve the output current THD. A small signal model of the inverter based on the transfer function approach is developed to analyse is stability and determine droop gains. Simulation and experimental results...

  4. A molybdenum disulfide/carbon nanotube heterogeneous complementary inverter.

    Science.gov (United States)

    Huang, Jun; Somu, Sivasubramanian; Busnaina, Ahmed

    2012-08-24

    We report a simple, bottom-up/top-down approach for integrating drastically different nanoscale building blocks to form a heterogeneous complementary inverter circuit based on layered molybdenum disulfide and carbon nanotube (CNT) bundles. The fabricated CNT/MoS(2) inverter is composed of n-type molybdenum disulfide (MOS(2)) and p-type CNT transistors, with a high voltage gain of 1.3. The CNT channels are fabricated using directed assembly while the layered molybdenum disulfide channels are fabricated by mechanical exfoliation. This bottom-up fabrication approach for integrating various nanoscale elements with unique characteristics provides an alternative cost-effective methodology to complementary metal-oxide-semiconductors, laying the foundation for the realization of high performance logic circuits.

  5. PWM Inverter control and the application thereof within electric vehicles

    Science.gov (United States)

    Geppert, Steven

    1982-01-01

    An inverter (34) which provides power to an A.C. machine (28) is controlled by a circuit (36) employing PWM control strategy whereby A.C. power is supplied to the machine at a preselectable frequency and preselectable voltage. This is accomplished by the technique of waveform notching in which the shapes of the notches are varied to determine the average energy content of the overall waveform. Through this arrangement, the operational efficiency of the A.C. machine is optimized. The control circuit includes a micro-computer and memory element which receive various parametric inputs and calculate optimized machine control data signals therefrom. The control data is asynchronously loaded into the inverter through an intermediate buffer (38). In its preferred embodiment, the present invention is incorporated within an electric vehicle (10) employing a 144 VDC battery pack (32) and a three-phase induction motor (18).

  6. Analysis and Modeling of Transformerless Photovoltaic Inverter Systems

    DEFF Research Database (Denmark)

    Kerekes, Tamas

    The need for a cleaner environment and the continuous increase in power demands makes decentralized renewable energy production, like solar and wind, more and more interesting. Decentralized energy production using solar energy could be a solu-tion for balancing the continuously-increasing power...... be improved in terms of efficiency using transformerless topologies, but new problems related to leakage current need to be dealt with. The work presented in this thesis deals with analyzing and modeling of transfor-merless PV inverter systems regarding the leakage current phenomenon that can damage solar...... panels and pose safety problems. The major task of this research was the investigation and verification of trans-formerless topologies and control strategies to minimize the leakage current of PV inverter topologies in order to comply with the standard requirements and make them safe for human...

  7. Extended SVM algorithms for multilevel trans-Z-source inverter

    Directory of Open Access Journals (Sweden)

    Aida Baghbany Oskouei

    2016-03-01

    Full Text Available This paper suggests extended algorithms for multilevel trans-Z-source inverter. These algorithms are based on space vector modulation (SVM, which works with high switching frequency and does not generate the mean value of the desired load voltage in every switching interval. In this topology the output voltage is not limited to dc voltage source similar to traditional cascaded multilevel inverter and can be increased with trans-Z-network shoot-through state control. Besides, it is more reliable against short circuit, and due to several number of dc sources in each phase of this topology, it is possible to use it in hybrid renewable energy. Proposed SVM algorithms include the following: Combined modulation algorithm (SVPWM and shoot-through implementation in dwell times of voltage vectors algorithm. These algorithms are compared from viewpoint of simplicity, accuracy, number of switching, and THD. Simulation and experimental results are presented to demonstrate the expected representations.

  8. Operational analysis and comparative evaluation of embedded Z-Source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    This paper presents various embedded Z-source (EZ-source) inverters broadly classified as shunt or parallel embedded Z-source inverter. Being different from the traditional Z-source inverter, EZ-source inverters are constructed by inserting dc sources into the X-shaped impedance network so...... that the dc input current flows smoothly during the whole switching period unlike the traditional Z-source inverter. This feature is interesting when PV panels or fuel cells are assumed to power load since the continuous input current flow reduces control complexity of dc source and system design burden....... Carefully analyzing the operational principles for shoot-through and nonshoot-through switching, it is first revealed that the shunt-embedded Z-source inverters with capacitors partially or fully replaced by dc sources can appropriately perform buck-boost operation with rear-end current source inverter (CSI...

  9. An SCR inverter with an integral battery charger for electric vehicles

    Science.gov (United States)

    Thimmeach, D.

    1983-01-01

    The feasibility of incorporating an onboard battery charger into the inverter previously developed under a NASA contract is successfully demonstrated. The rated output power of the resulting isolated battery charger is 3.6 kW at 220 Vac with an 86 percent efficiency and a 95 percent power factor. Also achieved are improved inverter efficiency (from 90 to 93 percent at 15 kW motor shaft power), inverter peak power capability (from 26 to 34 kW), and reduced weight and volume of the combined inverter/charger package (47 kg, 49 x 44 x 24 cm). Some major conclusions are that using the inverter commutation circuitry to perform the battery charging function is advantageous, and that the input-commutated thyristor inverter has the potential to be an excellent inverter and battery charger for use in electric vehicle applications.

  10. Modelling of the modified-LLCL-filter-based single-phase grid-tied Aalborg inverter

    DEFF Research Database (Denmark)

    Liu, Zifa; Wu, Huiyun; Liu, Yuan

    2017-01-01

    Owing to less conduction and switching power losses, the recently proposed Aalborg inverter has high efficiency within a wide range of input DC voltage for single-phase DC/AC power conversion. In theory, the conduction power losses can be further decreased, if an LLCL-filter is adopted instead....... In this study, the small signal analysis for the modified-LLCL-filter-based Aalborg inverter is addressed. Through the modelling, it can be proven that compared with the LCL-filter, the modified-LLCL-filter causes no extra control challenge for the Aalborg inverter, and therefore more inductance in the power...... of an LCL-filter for a voltage source inverter, mainly due to the reduced inductance. The Aalborg inverter shows the characteristic of a current source inverter, when working in the `boost' state. Whether the LLCL-filter can meet the control requirement of this type inverter needs to be further explored...

  11. Inverter VAR control for distribution systems with renewables

    OpenAIRE

    Farivar, Masoud; Clarke, Christopher R.; Low, Steven H.; Chandy, K. Mani

    2011-01-01

    Motivated by the need to cope with rapid and random fluctuations of renewable generation, we presents a model that augments the traditional Volt/VAR control through switched controllers on a slow timescale with inverter control on a fast timescale. The optimization problem is generally nonconvex and therefore hard to solve. We propose a simple convex relaxation and prove that it is exact provided over-satisfaction of load is allowed. Hence Volt/VAR control over radial networks is efficiently ...

  12. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    Science.gov (United States)

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  13. Multiple cutaneous inverted papillomas in a dog : clinical communication

    Directory of Open Access Journals (Sweden)

    E.P. Lane

    2007-06-01

    Full Text Available Cutaneous inverted papillomas are described in an 8-month-old mixed breed domestic dog from Windhoek, Namibia. Multiple firm, rapidly growing, doughnut-shaped masses formed on the ventral abdomen, which histologically consisted of a cup-shaped rim of marked epithelial hyperplasia, giant keratohyaline granules and prominent koilocytes and marked hyperkeratosis filling the centre of the mass. Current literature on canine papillomas is briefly reviewed.

  14. Bilateral impacted inverted mesiodens associated with dentigerous cyst.

    Science.gov (United States)

    Byatnal, Aditi Amit; Byatnal, Amit; Singh, Ankur; Narayanaswamy, Venkadasalapathi; Radhakrishnan, Raghu

    2013-10-01

    Mesiodens, the most common type of supernumerary tooth, usually results in malocclusion, poor esthetics and cyst formation. The occurrence of a dentigerous cyst around the crown of an unerupted supernumerary tooth is infrequent. We present a case of a dentigerous cyst associated with a nonsyndromic bilateral impacted inverted supernumerary tooth in a 13-year-old boy. A thorough clinical workup, including 3-D reconstruction image and histological examination confirming the features of a dentigerous cyst is presented in this report.

  15. Inverted Pendulum-type Personal Mobility Considering Human Vibration Sensitivity

    OpenAIRE

    Misaki Masuda; Takuma Suzuki; Kazuto Yokoyama

    2014-01-01

    An inverted pendulum-type PM (personal mobility) has been attracting attention as a low-carbon vehicle. For many people who like to use the PM, ride comfort is important. However, ride comfort of PM has not been focused on in previous studies. The vibration is one of causes that make riders feel uncomfortable. The PM is unstable system and horizontal vibration may be caused by a stabilizing control. Additionally, vertical vibration may also be caused by road disturbances. This study analyzes ...

  16. Common methodology for steady state harmonic analysis of inverters

    Energy Technology Data Exchange (ETDEWEB)

    Vittek, J. [Technical Univ. of Transport and Communication, Zilina (Slovakia). Dept. of Electric Traction and Energetics; Najjar, M.Y. [Cleveland State Univ., OH (United States)

    1995-07-01

    This paper shows the time advantage analysis of m-phase symmetrical inverter systems in complex plane. Computation time reduction occurs due to the 2m-side symmetry in complex plane of such systems. Equations of characteristic values of voltage and current waveforms in the complex domain are developed. The validity of the analysis is shown for single and three phase symmetrical systems under three different modulation techniques using the equations presented in this paper.

  17. Inverted polymer solar cells with reduced interface recombination

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Song; Small, Cephas E.; Subbiah, Jegadesan; Lai, Tzung-han; Tsang, Sai-Wing; Manders, Jesse R.; So, Franky [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611 (United States); Amb, Chad M. [The George and Josephine Butler Polymer Research Laboratory, Department of Chemistry, Center of Macromolecular Science and Engineering, University of Florida, Gainesville, Florida 32611 (United States); Reynolds, John R. [School of Chemistry and Biochemistry, School of Materials Science and Engineering, Center for Organic Photonics and Electronics, Georgia Institute of Technology, Altanta, GA, 30332-0400 (United States)

    2012-11-15

    Interface recombination induced by the defect states in zinc-oxide-nanoparticle-based electron extraction layer is reported as a significant loss-mechanism of photocurrent collection. By choosing appropriate UV-ozone treatment conditions on the zinc oxide layer, inverted polymer solar cells show reduced interface recombination and thus improved power conversion efficiencies of up to 8.1%. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. A new surgical procedure for the very severe inverted nipple.

    Science.gov (United States)

    Sakai, S; Sakai, Y; Izawa, H

    1999-01-01

    Severe cases of inverted nipple usually cannot be corrected by a simple procedure, especially if the nipple cannot be pulled out above the areolar level by manipulation. We describe a new method for these cases and we classify the inverted nipple into 3 grades following the choice of their required operative procedure. Our classification for inverted nipple is as follows. Grade I: The inversion is corrected simply by manipulation; the nipple protrusion is long-lasting. Grade II: The inversion can be corrected by manipulation, but recurrence of the inversion is frequent. Grade III: The inversion cannot be corrected without a surgical procedure. Cases of Grades I and II can be corrected by conventional simple surgical procedures. But some cases of Grade II and almost all of Grade III cannot be corrected by conventional methods, in spite of the high frequency of relapse. Cutting of the lactiferous duct, such as the Pitanguy and Broadbent methods, can correct the very severely inverted nipple. But if we want to maintain the lactiferous function after correction, we had better not cut the lactiferous ducts. Our new procedure for correcting very severe cases can keep the lactiferous function after correction without any relapse. In order to avoid the recurrence of nipple retraction and to maintain the lactiferous function, the new surgical procedure that we performed makes an incision deeply and vertically on the nipple to free the lactiferous ducts from the contracted tissues surrounding them. After extension or resection of the restricting tissues, the nipple is raised easily. This procedure will preserve the feeding function and prevent the recurrence of nipple inversion. For very severe cases, using a dermal flap inserted into the base of the nipple may be necessary due to its role of interposing tissue to prevent reverting to inversion.

  19. Analysis and design of controllers for a double inverted pendulum

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, J K

    2003-01-01

    A physical control problem is studied with the μ methodology. The issues of modelling, uncertainty modelling, performance specification, controller design and laboratory implementation are discussed. The laboratory experiment is a double inverted pendulum placed on a cart. The limitations...... in the system with respect to performance are the limitation in the control signal and the limitation of the movement of the chart. It is shown how these performance limitation will effect the design of a μ controller for the system....

  20. Hybrid LQG-Neural Controller for Inverted Pendulum System

    OpenAIRE

    Sazonov, E. S.; Klinkhachorn, P.; Klein, R. L.

    2003-01-01

    The paper presents a hybrid system controller, incorporating a neural and an LQG controller. The neural controller has been optimized by genetic algorithms directly on the inverted pendulum system. The failure free optimization process stipulated a relatively small region of the asymptotic stability of the neural controller, which is concentrated around the regulation point. The presented hybrid controller combines benefits of a genetically optimized neural controller and an LQG controller in...

  1. Inverting Paradigms and Identifying Monstrosities in Juvenal's "Satire VI"

    OpenAIRE

    Gould, Matthew James

    2012-01-01

    In this paper, I offer a reading of Juvenal’s “Satire VI” as an example of ancient Roman satirists’ use of inversion, one of many techniques meant to invite political criticism without attracting the wrong kinds of autocratic attention. I claim that Juvenal inverts the paradigmatic father-son[-wife] relationship with a wife-husband-child chain to suggestively critique Roman governmental authority. This examination includes the relationship between the autocracy and aristocracy in ancient Rome...

  2. Phase synchronized quasiperiodicity in power electronic inverter systems

    DEFF Research Database (Denmark)

    Zhusubaliyev, Zhanybai T.; Mosekilde, Erik; Andriyanov, Alexey I.

    2014-01-01

    The development of switch-mode operated power electronic converter systems has provided a broad range of new effective approaches to the conversion of electric power. In this paper we describe the transitions from regular periodic operation to quasiperiodicity and high-periodic resonance behavior...... findings are verified through comparison with an experimental inverter system. The results shed light on the transitions to quasiperiodicity and to various forms of three-frequency dynamics in non-smooth systems....

  3. A flexible inkjet printed inverted-F antenna on textile

    KAUST Repository

    Karimi, Muhammad Akram

    2016-12-19

    This is an era of wearable gadgets which demands flexible and wearer friendly wireless components. This paper presents a modified inverted-F antenna (IFA) which has seamlessly been integrated with the fabric through inkjet printing. Surface roughness of the textile has been reduced using a rapid UV curable flexible interface layer. Smooth interface layer helps achieving very fine features which may be required for complicated antenna and circuit traces.

  4. Rotary inverted pendulum: Trajectory tracking via nonlinear control techniques

    Czech Academy of Sciences Publication Activity Database

    Ramos-Velasco, Luis Enrique; Ruiz-León, J. J.; Čelikovský, Sergej

    2002-01-01

    Roč. 38, č. 2 (2002), s. 217-232 ISSN 0023-5954 R&D Projects: GA ČR GA102/02/0709 Grant - others: CONACYT (MX) 31844-A Institutional research plan: CEZ:AV0Z1075907 Keywords : nonlinear systems * rotary inverted pendulum * output regulation * sliding modes Subject RIV: BC - Control Systems Theory Impact factor: 0.341, year: 2002

  5. Correction of severely inverted nipple with telescope method.

    Science.gov (United States)

    Shiau, Jiun-Pyng; Chin, Chih-Ching; Lin, Mei-Hui; Hsiao, Cheng-Wei

    2011-12-01

    For female patients, an inverted nipple can result in functional problems, such as difficulty breast feeding, and emotional difficulties because of self-consciousness about the condition. Numerous surgical techniques for inverted nipple correction have been proposed, but none of the methods provides a reliable outcome. Most methods involve releasing retractile ducts and fibrous bands and adding bulk at the base of nipple; however, these techniques can cause injury to normal lactiferous ducts and sensory dysfunction. Herein we describe a "telescope method," performed under local anesthesia, which consists of making a circumferential incision, pulling out the nipple, and tightening the nipple base. With this technique, most lactiferous ducts and parallel sensory nerves that travel through the nipple base are not injured, and the procedure is associated with a less visible scar and nipple deformity than other methods. We report on 23 nipples of 17 patients that were successfully treated with this method. There was no recurrence of nipple inversion or sensory disturbance in the follow-up period. This technique is a simple, safe, and reliable method for the correction of severely inverted nipples.

  6. A grid-connected single-phase photovoltaic micro inverter

    Science.gov (United States)

    Wen, X. Y.; Lin, P. J.; Chen, Z. C.; Wu, L. J.; Cheng, S. Y.

    2017-11-01

    In this paper, the topology of a single-phase grid-connected photovoltaic (PV) micro-inverter is proposed. The PV micro-inverter consists of DC-DC stage with high voltage gain boost and DC-AC conversion stage. In the first stage, we apply the active clamp circuit and two voltage multipliers to achieve soft switching technology and high voltage gain. In addition, the flower pollination algorithm (FPA) is employed for the maximum power point tracking (MPPT) in the PV module in this stage. The second stage cascades a H-bridge inverter and LCL filter. To feed high quality sinusoidal power into the grid, the software phase lock, outer voltage loop and inner current loop control method are adopted as the control strategy. The performance of the proposed topology is tested by Matlab/Simulink. A PV module with maximum power 300W and maximum power point voltage 40V is applied as the input source. The simulation results indicate that the proposed topology and the control strategy are feasible.

  7. Inverted rank distributions: Macroscopic statistics, universality classes, and critical exponents

    Science.gov (United States)

    Eliazar, Iddo; Cohen, Morrel H.

    2014-01-01

    An inverted rank distribution is an infinite sequence of positive sizes ordered in a monotone increasing fashion. Interlacing together Lorenzian and oligarchic asymptotic analyses, we establish a macroscopic classification of inverted rank distributions into five “socioeconomic” universality classes: communism, socialism, criticality, feudalism, and absolute monarchy. We further establish that: (i) communism and socialism are analogous to a “disordered phase”, feudalism and absolute monarchy are analogous to an “ordered phase”, and criticality is the “phase transition” between order and disorder; (ii) the universality classes are characterized by two critical exponents, one governing the ordered phase, and the other governing the disordered phase; (iii) communism, criticality, and absolute monarchy are characterized by sharp exponent values, and are inherently deterministic; (iv) socialism is characterized by a continuous exponent range, is inherently stochastic, and is universally governed by continuous power-law statistics; (v) feudalism is characterized by a continuous exponent range, is inherently stochastic, and is universally governed by discrete exponential statistics. The results presented in this paper yield a universal macroscopic socioeconophysical perspective of inverted rank distributions.

  8. Radiation effect on sucrose content of inverted sugar

    International Nuclear Information System (INIS)

    Podadera, Priscilla; Sabato, Susy F.

    2007-01-01

    Inverted sugar is a mixture of sucrose, glucose and fructose used as an ingredient in the food and beverage industry. During production there are points of contamination by microorganisms that can modify the sugar properties and reduce shelf life. This work aims to consider one efficient technique in the sanitization of this ingredient with minimum alterations in the sugar ratios. Irradiation with Cobalt 60 is a technique with proven efficacy in the reduction of microorganisms. Samples of inverted sugar had been radiated with Cobalt 60, Gammacell type, at the CTR-IPEN, with doses of 5, 10, 20, 30 and 50 kGy, and dose rate of 3.88 kGy/h. The content of sucrose was determined by the Fehling method. The sample irradiated at highest dose presented the most intense reduction in the concentration of sucrose: 13% in comparison to the control. Irradiated samples up to 30 kGy did not presented statistical difference in relation to the control (p<0.05), indicating that radiation can be applied to the inverted sugar without significant alterations in the concentration of sucrose. (author)

  9. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  10. Single DV-DXCCII Based Voltage Controlled First Order All-pass Filter with Inverting and Non-inverting responses

    Directory of Open Access Journals (Sweden)

    B Chaturvedi

    2015-12-01

    Full Text Available In this paper, a new voltage controlled first order all-pass filter is presented. The proposed circuit employs a single differential voltage dual-X second generation current conveyor (DV-DXCCII and a grounded capacitor only. The proposed all-pass filter provides both inverting and non inverting voltage-mode outputs from the same configuration simultaneously without any matching condition. Non-ideal analysis along with sensitivity analysis is also investigated. The proposed circuit has low active and passive sensitivities. As an application the proposed all-pass filter is connected in cascade to get higher order filter. The theoretical results are validated thorough PSPICE simulations using TSMC 0.18µm CMOS process parameters.

  11. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...... cause noise amplification. In light of the above issue, this paper develops a simple method for the ICF control system to mitigate the grid current harmonics without extra sensors. In the proposed method, resonant harmonic controllers and an additional compensation loop are adopted at the same time...

  12. Test Protocols for Advanced Inverter Interoperability Functions – Main Document

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ralph, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already

  13. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ralph, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as

  14. The "LIFT" lesion: lateral inverted osteochondral fracture of the talus.

    Science.gov (United States)

    Dunlap, Bradley J; Ferkel, Richard D; Applegate, Gregory R

    2013-11-01

    The purpose of this study was to assess a series of lateral inverted osteochondral fractures of the talus. Over a 17-year period, 10 patients with an acute lateral inverted osteochondral fracture of the talus after an inversion injury to the ankle were identified. Diagnosis was made by physical examination, radiographs, magnetic resonance imaging, and/or computed tomography scan. Arthroscopy was initially performed on all patients. All patients had an inverted osteochondral fragment. In 8 of 10 patients the fragment was reattached in an open manner in conjunction with lateral ligament reefing. The fragment was excised in 2 patients. The mean age of the patients was 17.2 years. They were evaluated with the Single Assessment Numeric Evaluation, American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale, modified Weber score, Berndt and Harty score, and Short Form 36 version 2 score. Physical and radiographic examination was also performed. The mean time to follow-up was 112.3 months (9.3 years). The mean American Orthopaedic Foot and Ankle Society score improved from 18.9 preoperatively to 86.9 postoperatively (P ≤ .0001). The mean Single Assessment Numeric Evaluation and modified Weber scores were 81.6 and 81.5, respectively. On the Berndt and Harty scale, 6 patients had a good to excellent rating; 3, fair; and 1, poor. The mean Short Form 36 version 2 scores corresponded to national averages for healthy populations. Mean loss of motion for dorsiflexion and plantarflexion was 6.8° and 3.0°, respectively, when compared with the contralateral side. All patients showed some osteophyte formation on follow-up radiographs. An inverted osteochondral fracture of the lateral talus (lateral, inverted, fracture, talus [LIFT lesion]) can occur after a twisting injury to the ankle. Clinical suspicion should be high, especially in the younger athlete. This injury can be successfully managed with a combined arthroscopic and open approach. Level IV, therapeutic case

  15. The application of orthogonal photolithography to micro-scale organic field effect transistors and complementary inverters on flexible substrate

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jingon; Song, Younggul; Yoo, Daekyoung; Kim, Dongku; Lee, Hyungwoo; Hong, Seunghun; Lee, Takhee, E-mail: tlee@snu.ac.kr [Department of Physics and Astronomy, and Institute of Applied Physics, Seoul National University, Seoul 151-747 (Korea, Republic of); Oh, Hyuntaek; Lee, Jin-Kyun, E-mail: jkl36@inha.ac.kr [Department of Polymer Science and Engineering, Inha University, Incheon 402-751 (Korea, Republic of)

    2014-02-03

    Micro-scale pentacene organic field effect transistors (OFETs) were fabricated on a flexible poly(ethylene terephthalate) (PET) substrate. By applying a highly fluorinated developing solvents and its compatible photoresist materials, it has become possible to make the micro-scale patterning for organic devices using standard photolithography without damaging the underlying polymer layers. The flexible pentacene OFETs with 3 μm-sized channel length exhibited stable electrical characteristics under bent configurations and under a large number of repetitive bending cycles. Furthermore, we demonstrated micro-scale organic complementary inverters on a flexible PET substrate using p-type pentacene and n-type copper hexadecafluorophthalocyanine materials.

  16. The application of orthogonal photolithography to micro-scale organic field effect transistors and complementary inverters on flexible substrate

    International Nuclear Information System (INIS)

    Jang, Jingon; Song, Younggul; Yoo, Daekyoung; Kim, Dongku; Lee, Hyungwoo; Hong, Seunghun; Lee, Takhee; Oh, Hyuntaek; Lee, Jin-Kyun

    2014-01-01

    Micro-scale pentacene organic field effect transistors (OFETs) were fabricated on a flexible poly(ethylene terephthalate) (PET) substrate. By applying a highly fluorinated developing solvents and its compatible photoresist materials, it has become possible to make the micro-scale patterning for organic devices using standard photolithography without damaging the underlying polymer layers. The flexible pentacene OFETs with 3 μm-sized channel length exhibited stable electrical characteristics under bent configurations and under a large number of repetitive bending cycles. Furthermore, we demonstrated micro-scale organic complementary inverters on a flexible PET substrate using p-type pentacene and n-type copper hexadecafluorophthalocyanine materials

  17. Treatment of unilateral giant fibroadenoma by breast reduction skin incision: the inverted "T" technique.

    Science.gov (United States)

    Achebe, J U; Njeze, G E; Okwesili, O R

    2014-01-01

    Giant fibroadenoma (GFA) has been defined as fibroadenoma greater than 5 cm in it's the widest diameter and/or weighing more than 500 g. A benign lesion, its size also raises the possibility of malignancy requiring differentiation from a malignant breast disease. When unilateral GFA presents with a severe breast asymmetry, due to its size, it is not correctable by simple enucleation alone. Postoperative asymmetry from volume and ptosis disparity results, which needs to be addressed at the primary surgery. The inverted "T" technique, which is effective in volume reduction and ptosis correction in breast hypertrophy, can be applied in the treatment of unilateral GFA. This is a retrospective review of all GFA treated by inverted "T" method. A retrospective review was carried out on all patients with GFA treated by inverted "T" skin pattern method over a period of 20 years (January 1988 to December 2007). The procedures were carried out at the University of Nigeria Teaching Hospital and the National Orthopedic Hospital, Enugu. Information, which included patients' demographics, pre-operative assessment, operative findings and outcome of surgery were obtained from the case files of the patients. The degree of ptosis was recorded for each patient. Diagnosis of GFA was made after clinical evaluation and pre-operative tissue biopsy. Immediate results of treatment were based on the patients' satisfaction, visual assessment of symmetry of size of breasts, correction of ptosis and position of nipple areola complex (NAC). A total of 27 patients underwent inverted "T" technique for excision of GFA in their breasts. Their average age was 17.5 years (range 12-25 years) delay in presentation ranged from 2 months to 15 months. In 16 patients (59.2%), the left breast was involved in GFA whilst the tumor occurred on the right breast in 11 (40.7%). The tumor weighed on the average 1500 g (range 655-2200 g). Average diameter of the tumor was 15 cm (range 12-20 cm). All quadrants of the

  18. The Google High Power Density Inverter Prize: Innovation in PV Inverter Power Density: Cooperative Research and Development Final Report, CRADA Number: CRD-14-568

    Energy Technology Data Exchange (ETDEWEB)

    Lundstrom, Blake [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-08

    Google is encouraging development of advanced photovoltaic inverters with high power density by holding a public competition and offering a prize for the best performing high power developed. NREL will perform the performance and validation for all inverters entered into the competition and provide results to Google.

  19. Comparison of three-phase three-level voltage source inverter with intermediate dc–dc boost converter and quasi-Z-source inverter

    DEFF Research Database (Denmark)

    Panfilov, Dmitry; Husev, Oleksandr; Blaabjerg, Frede

    2016-01-01

    This study compares a three-phase three-level voltage source inverter with an intermediate dc-dc boost converter and a quasi-Z-source inverter in terms of passive elements values and dimensions, semiconductor stresses, and overall efficiency. A comparative analysis was conducted with relative...

  20. Integration of Xantrex HY-100 Hybrid Inverter with an AC Induction Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Corbus, D.; Newcomb, C.; Friedly, S.

    2003-05-01

    Several issues must be addressed before solid-state inverters can be used in wind-diesel systems with larger wind turbines. This project addresses those issues by using a commercial hybrid inverter designed for PV-diesel systems and modifying the inverter for use with an AC induction wind turbine. Another approach would have entailed building an inverter specifically for use with an AC induction wind turbine, but that was beyond the scope of this project. The inverter chosen for this project was a Xantrex HY-100, an inverter designed for PV systems. The unit consists of an inverter/rectifier bridge, a generator interface contactor, a battery charge controller, a hybrid controller, and the associated control electronics. Details of the inverter may be found in Appendix A. A twofold approach was taken to integrating the existing inverter for use with an AC induction wind turbine: 1) development of a detailed model to model both steady-state and transient behavior of the system, and 2) modification and testing of the inverter with an induction wind turbine based on the modeling results. This report describes these two tasks.