WorldWideScience

Sample records for intravascular ultrasound study

  1. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  2. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    Science.gov (United States)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  3. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  4. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    presenting with a DES or bare-metal stent (BMS) in-stent restenosis. Methods: The ``Nordic Intravascular Ultrasound Study (NIVUS)'' study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n = 121 and BMS n = 88) with instent restenosis were...

  5. Intravascular Ultrasound Imaging of Peripheral Arteries as an Adjunct to Balloon Angioplasty and Atherectomy

    International Nuclear Information System (INIS)

    Korogi, Yukunori; Hirai, Toshinori; Takahashi, Mutsumasa

    1996-01-01

    This article reviews many of the applications of intravascular ultrasound (US) imaging for peripheral arterial diseases. In vitro studies demonstrate an excellent correlation between ultrasound measurements of lumen and plaque crossectional area compared with histologic sections. In vivo clinical studies reveal the enhanced diagnostic capabilities of this technology compared with angiography. Intravascular US imaging can provide valuable information on the degree, eccentricity, and histologic type of stenosis before intervention, and on the morphological changes in the arterial wall and the extent of excision after intervention. Intravascular US may also serve as a superior index for gauging the diameter of balloon, stent, laser probe, and/or atherectomy catheter appropriate for a proposed intervention. Significant new insights into the mechanisms of balloon angioplasty and atherectomy have been established by intravascular US findings. Intravascular US imaging has been shown to be a more accurate method than angiography for determining the cross-sectional area of the arterial lumen, and for assessing severity of stenosis. Quantitative assessment of the luminal cross-sectional area after the balloon dilatation should be more accurate than angiography as intimal tears or dissections produced by the dilatation may not be accurately evaluated with angiography. At the present time, intravascular US is still a controversial imaging technique. Outcome studies are currently being organized to assess the clinical value and cost effectiveness of intravascular ultrasound in the context of these interventional procedures

  6. Association of insulin resistance and coronary artery remodeling: an intravascular ultrasound study

    OpenAIRE

    Kim, Sang-Hoon; Moon, Jae-Youn; Lim, Yeong Min; Kim, Kyung Ho; Yang, Woo-In; Sung, Jung-Hoon; Yoo, Seung Min; Kim, In Jai; Lim, Sang-Wook; Cha, Dong-Hun; Cho, Seung-Yun

    2015-01-01

    Background There are few studies that investigated the correlation between insulin resistance (IR) and the coronary artery remodeling. The aim of the study is to investigate the association of IR measured by homeostasis model assessment of insulin resistance (HOMA-IR) and coronary artery remodeling evaluated by intravascular ultrasound (IVUS). Methods A total of 298 consecutive patients who received percutaneous coronary interventions under IVUS guidance were retrospectively enrolled. The val...

  7. Currently available methodologies for the processing of intravascular ultrasound and optical coherence tomography images.

    Science.gov (United States)

    Athanasiou, Lambros; Sakellarios, Antonis I; Bourantas, Christos V; Tsirka, Georgia; Siogkas, Panagiotis; Exarchos, Themis P; Naka, Katerina K; Michalis, Lampros K; Fotiadis, Dimitrios I

    2014-07-01

    Optical coherence tomography and intravascular ultrasound are the most widely used methodologies in clinical practice as they provide high resolution cross-sectional images that allow comprehensive visualization of the lumen and plaque morphology. Several methods have been developed in recent years to process the output of these imaging modalities, which allow fast, reliable and reproducible detection of the luminal borders and characterization of plaque composition. These methods have proven useful in the study of the atherosclerotic process as they have facilitated analysis of a vast amount of data. This review presents currently available intravascular ultrasound and optical coherence tomography processing methodologies for segmenting and characterizing the plaque area, highlighting their advantages and disadvantages, and discusses the future trends in intravascular imaging.

  8. P-shaped Coiled Stator Ultrasound Motor for Rotating Intravascular Surgery Device

    Directory of Open Access Journals (Sweden)

    Toshinobu ABE

    2015-01-01

    Full Text Available The primary focus of this paper is the development of an ultra-miniature ultrasound motor for use in the human blood vessel. Since the size of the drive source for rotating the atherectomy device and intravascular ultrasonography system are large currently in practical use, it is installed outside the body, and the rotational power for the atherectomy device and intravascular ultrasonography system are transmitted through the long tortuous blood vessel. Such systems suffer from the problem that the rotation becomes non-uniform, and the problem that the available time is limited. We have therefore developed a P-shaped coiled stator ultrasound motor as a miniature ultrasound motor for rotating the ultrasound sensor for use in blood vessels in order to solve these problems. In this paper, we describe measurement of the torque, revolution speed, output power, efficiency, and particle motion on acoustic waveguide of the P-shaped coiled stator ultrasound motor.

  9. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  10. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  11. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  12. Heterogeneous Intravascular Ultrasound Findings of Stent Thrombosis

    OpenAIRE

    Morofuji, Toru; Inaba, Shinji; Aisu, Hiroe; Takahashi, Kayo; Saito, Makoto; Higashi, Haruhiko; Yoshii, Toyofumi; Sumimoto, Takumi

    2017-01-01

    Objective The underlying mechanisms of stent thrombosis are not completely understood. Methods We experienced 12 definite stent thrombosis cases (1 early, 1 late, and 10 very late) at our hospital from July 2011 to April 2016 and evaluated the possible causes of stent thrombosis by intravascular ultrasound (IVUS). Results Five different potential morphological causes of stent thrombosis (neoatherosclerosis, stent malapposition, stent fracture, edge dissection, and stent underexpansion) were d...

  13. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-01-01

    Abstract. We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures. PMID:24898604

  14. Intravascular ultrasound evaluation of a pseudolesion created by stent placement in the right artery.

    Science.gov (United States)

    Zientek, D M; Rodgers, G P

    1999-10-01

    The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.

  15. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  16. Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound

    Science.gov (United States)

    von Birgelen, C; Mintz, G; de Vrey, E A; Serruys, P; Kimura, T; Nobuyoshi, M; Popma, J; Leon, M; Erbel, R; de Feyter, P J

    2000-01-01

    AIMS—To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention.
DESIGN—29 lesion segments in 29 patients were examined with intravascular ultrasound before and after successful balloon optimised directional coronary atherectomy procedures, and a validated volumetric intravascular ultrasound analysis was performed off-line to assess the atherosclerotic lesion remodelling and changes in plaque and vessel volumes that occurred during the intervention. Based on the intravascular ultrasound data, lesions were classified according to whether there was inadequate (group I) or adequate (group II) compensatory enlargement.
RESULTS—There was no significant difference in patient and lesion characteristics between groups I and II (n = 10 and 19), including lesion length and details of the intervention. Quantitative coronary angiographic data were similar for both groups. However, plaque and vessel volumes were significantly smaller in group I than in II. In group I, 9 (4)% (mean (SD)) of the plaque volume was ablated, while in group II 16 (11)% was ablated (p = 0.01). This difference was reflected in a lower lumen volume gain in group I than in group II (46 (18) mm3 v 80 (49) mm3 (p atherectomy procedures. Plaque ablation was found to be particularly low in lesions with inadequate compensatory vascular enlargement.


Keywords: intravascular ultrasound; ultrasonics; remodelling; coronary artery disease; atherectomy PMID:10648496

  17. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  18. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  19. Impact of statin therapy on coronary plaque composition: A systematic review and meta-analysis of virtual histology intravascular ultrasound studies

    NARCIS (Netherlands)

    M. Banach (Maciej); C. Serban (Corina); A. Sahebkar (Amirhossein); D.P. Mikhailidis (Dimitri P.); S. Ursoniu (Sorin); K.K. Ray (Kausik K.); J. Rysz (Jacek); P.P. Toth (Peter); P. Muntner (Paul); S. Mosteoru (Svetlana); H.M. Garcia-Garcia (Hector); G.K. Hovingh (Kees); J.J.P. Kastelein (John); P.W.J.C. Serruys (Patrick)

    2015-01-01

    textabstractBackground: Virtual histology intravascular ultrasound (VH-IVUS) imaging is an innovative tool for the morphological evaluation of coronary atherosclerosis. Evidence for the effects of statin therapy on VH-IVUS parameters have been inconclusive. Consequently, we performed a systematic

  20. Impact of statin therapy on coronary plaque composition: a systematic review and meta-analysis of virtual histology intravascular ultrasound studies

    NARCIS (Netherlands)

    Banach, Maciej; Serban, Corina; Sahebkar, Amirhossein; Mikhailidis, Dimitri P.; Ursoniu, Sorin; Ray, Kausik K.; Rysz, Jacek; Toth, Peter P.; Muntner, Paul; Mosteoru, Svetlana; García-García, Hector M.; Hovingh, G. Kees; Kastelein, John J. P.; Serruys, Patrick W.

    2015-01-01

    Virtual histology intravascular ultrasound (VH-IVUS) imaging is an innovative tool for the morphological evaluation of coronary atherosclerosis. Evidence for the effects of statin therapy on VH-IVUS parameters have been inconclusive. Consequently, we performed a systematic review and meta-analysis

  1. The clinical importance and prediction of steal following femoro-femoral cross-over bypass: study of the donor iliac artery by intravascular ultrasound, arteriography, duplex scanning and pressure measurements

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, J G; Schroeder, T V

    2000-01-01

    to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal.......to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal....

  2. A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis

    NARCIS (Netherlands)

    E.S. Shin (Eun-Seok); H.M. Garcia-Garcia (Hector); P.W.J.C. Serruys (Patrick)

    2010-01-01

    textabstractAlthough previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that of lumen contour, because of the limited IVUS resolution. The purpose of this study was

  3. Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound.

    Science.gov (United States)

    Bec, Julien; Xie, Hongtao; Yankelevich, Diego R; Zhou, Feifei; Sun, Yang; Ghata, Narugopal; Aldredge, Ralph; Marcu, Laura

    2012-10-01

    We report the development and validation of an intravascular rotary catheter for bimodal interrogation of arterial pathologies. This is based on a point-spectroscopy scanning time-resolved fluorescence spectroscopy technique enabling reconstruction of fluorescence lifetime images (FLIm) and providing information on arterial intima composition and intravascular ultrasound (IVUS) providing information on arterial wall morphology. The catheter design allows for independent rotation of the ultrasonic and optical channels within an 8 Fr outer diameter catheter sheath and integrates a low volume flushing channel for blood removal in the optical pathways. In the current configuration, the two channels consist of (a) a standard 3 Fr IVUS catheter with single element transducer (40 MHz) and (b) a side-viewing fiber optic (400 μm core). Experiments conducted in tissue phantoms showed the ability of the catheter to operate in an intraluminal setting and to generate coregistered FLIm and IVUS in one pull-back scan. Current results demonstrate the feasibility of the catheter for simultaneous bimodal interrogation of arterial lumen and for generation of robust fluorescence lifetime data under IVUS guidance. These results facilitate further development of a FLIm-IVUS technique for intravascular diagnosis of atherosclerotic cardiovascular diseases including vulnerable plaques.

  4. Head to head comparison of optical coherence tomography, intravascular ultrasound echogenicity and virtual histology for the detection of changes in polymeric struts over time

    DEFF Research Database (Denmark)

    Brugaletta, Salvatore; Gomez-Lara, Josep; Bruining, Nico

    2012-01-01

    To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the A......To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation...

  5. Orbital Atherectomy Plaque Modification Assessment of the Femoropopliteal Artery Via Intravascular Ultrasound (TRUTH Study).

    Science.gov (United States)

    Babaev, Anvar; Zavlunova, Susanna; Attubato, Michael J; Martinsen, Brad J; Mintz, Gary S; Maehara, Akiko

    2015-10-01

    The Tissue Removal Assessment with Ultrasound of the SFA and Popliteal (TRUTH) study assessed the performance of the orbital atherectomy system (OAS) to treat femoropopliteal arteries, including determining its effect on plaque removal. Patients with symptomatic femoropopliteal peripheral arterial disease were treated with the OAS followed by adjunctive balloon angioplasty (BA). Intravascular ultrasound (IVUS) images were collected pre- and post-OAS and post-OAS BA. Patients were followed through 12 months post-procedure. Twenty-nine lesions were treated with OAS-BA in 25 patients. The mean maximum balloon inflation pressure was 5.2 ± 1.2 atm. Virtual histology IVUS (VH-IVUS) analysis revealed at the maximum calcium ablation site that calcium reduction was responsible for 86% of the lumen area increase. The minimum lumen area increased from 4.0 mm(2) to 9.1 mm(2) (<.0001), and the percentage of area stenosis decreased from 76.9% to 43.0% (<.0001) after OAS-BA. At 12 months, the target lesion revascularization rate was 8.2%, and ankle-brachial index and Rutherford classification improved significantly from baseline through follow-up. The VH-IVUS analysis reveals that OAS modifies the calcified component of the plaque burden. It is hypothesized that calcium modification by OAS changes the lesion compliance, allowing for low pressure adjunctive BA. The clinical outcomes were favorable through 12-month follow-up. © The Author(s) 2015.

  6. Focus on the research utility of intravascular ultrasound - comparison with other invasive modalities

    Directory of Open Access Journals (Sweden)

    Hoye Angela

    2011-01-01

    Full Text Available Abstract Intravascular ultrasound (IVUS is an invasive modality which provides cross-sectional images of a coronary artery. In these images both the lumen and outer vessel wall can be identified and accurate estimations of their dimensions and of the plaque burden can be obtained. In addition, further processing of the IVUS backscatter signal helps in the characterization of the type of the plaque and thus it has been used to study the natural history of the atherosclerotic evolution. On the other hand its indigenous limitations do not allow IVUS to assess accurately stent struts coverage, existence of thrombus or exact site of plaque rupture and to identify some of the features associated with increased plaque vulnerability. In order this information to be obtained, other modalities such as optical coherence tomography, angioscopy, near infrared spectroscopy and intravascular magnetic resonance imaging have either been utilized or are under evaluation. The aim of this review article is to present the current utilities of IVUS in research and to discuss its advantages and disadvantages over the other imaging techniques.

  7. Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis.

    Science.gov (United States)

    Kim, Jinwook; Lindsey, Brooks D; Chang, Wei-Yi; Dai, Xuming; Stavas, Joseph M; Dayton, Paul A; Jiang, Xiaoning

    2017-06-14

    Effective removal or dissolution of large blood clots remains a challenge in clinical treatment of acute thrombo-occlusive diseases. Here we report the development of an intravascular microbubble-mediated sonothrombolysis device for improving thrombolytic rate and thus minimizing the required dose of thrombolytic drugs. We hypothesize that a sub-megahertz, forward-looking ultrasound transducer with an integrated microbubble injection tube is more advantageous for efficient thrombolysis by enhancing cavitation-induced microstreaming than the conventional high-frequency, side-looking, catheter-mounted transducers. We developed custom miniaturized transducers and demonstrated that these transducers are able to generate sufficient pressure to induce cavitation of lipid-shelled microbubble contrast agents. Our technology demonstrates a thrombolysis rate of 0.7 ± 0.15 percent mass loss/min in vitro without any use of thrombolytic drugs.

  8. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    NARCIS (Netherlands)

    Huisman, Jeroen; Egede, R.; Rdzanek, A.; Böse, D.; Erbel, R.; van der Palen, Jacobus Adrianus Maria; von Birgelen, Clemens

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility

  9. Impact of analyzing fewer image frames per segment during offline volumetric radiofrequency based intravascular ultrasound measurements of target lesions prior to percutaneous coronary interventions

    NARCIS (Netherlands)

    Huisman, J.; Hartmann, M.; Hartmann, M.; Mintz, G.S.; van Houwelingen, G.K.; Stoel, M.G.; de Man, F.H.; Louwerenburg, H.; von Birgelen, Clemens

    2012-01-01

    In the present study, we evaluated the impact of a 50% reduction in number of image frames (every second frame) on the analysis time and variability of offline volumetric radiofrequency-based intravascular ultrasound (RF-IVUS) measurements in target lesions prior to percutaneous coronary

  10. Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

    Science.gov (United States)

    Nakamura, M; Yock, P G; Bonneau, H N; Kitamura, K; Aizawa, T; Tamai, H; Fitzgerald, P J; Honda, Y

    2001-05-01

    Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (Pexterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.

  11. Intravascular ultrasound based dose assessment in endovascular brachytherapy

    International Nuclear Information System (INIS)

    Catalano, Gianpiero; Tamburini, Vittorio; Colombo, Antonio; Nishida, Takahiro; Parisi, Giovanni; Mazzetta, Chiara; Orecchia, Roberto

    2003-01-01

    Background: the role of endovascular brachytherapy in restenosis prevention is well documented. Dose is usually prescribed at a fixed distance from the source axis by angiographic quantification of vessel diameter. Recently, intravascular ultrasound (IVUS) was introduced in dose prescription, allowing a better evaluation of the vessel anatomy. This study retrospectively explores the difference between prescription following angiographic vessel sizing and delivered dose calculated with IVUS. Methods and results: Seventeen lesions were studied with IVUS, identifying on irradiated segment, three sections on which measuring minimal and maximal distance from the centre of IVUS catheter to the adventitia; using dedicated software, corresponding doses were calculated. The dose ranged widely, with maximal and minimal values of 71.6 and 4.9 Gy; furthermore, heterogeneity in dose among different sections was observed. In the central section, the maximal dose was 206% of the one prescribed with the QCA model at 2 mm from the source axis, while the minimal dose was 96%. In proximal and distal sections, respective values were 182, 45, 243, and 122%. Conclusions: Our analysis confirmed the dose inhomogeneity delivered with an angiographic fixed-dose prescription strategy. A dose variation was found along the irradiated segment due to the differences in vessel thickness. IVUS emerged as an important tool in endovascular brachytherapy, especially for irregular-shaped vessels

  12. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound

    OpenAIRE

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Śpiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin

    2013-01-01

    Introduction Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. Aim To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Material and methods Two hundred and...

  13. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  14. Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents

    International Nuclear Information System (INIS)

    Kirisits, Christian; Wexberg, Paul; Gottsauner-Wolf, Michael; Pokrajac, Boris; Ortmann, Elisabeth; Aiginger, Hannes; Glogar, Dietmar; Poetter, Richard

    2001-01-01

    Background and purpose: Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. Materials and methods: Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean±SD. Results: The mean activity of the stents was 438±140 kBq at implantation. The mean reference dose was 111±35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68±20 Gy. On average, DV90 and DV10 were 33±9 Gy and 117±41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55±17 Gy, and DV 90 and DV 10 were 6.4±2.4 Gy and 107±36 Gy, respectively. Conclusions: The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy

  15. A state-of-the-art review on segmentation algorithms in intravascular ultrasound (IVUS) images.

    Science.gov (United States)

    Katouzian, Amin; Angelini, Elsa D; Carlier, Stéphane G; Suri, Jasjit S; Navab, Nassir; Laine, Andrew F

    2012-09-01

    Over the past two decades, intravascular ultrasound (IVUS) image segmentation has remained a challenge for researchers while the use of this imaging modality is rapidly growing in catheterization procedures and in research studies. IVUS provides cross-sectional grayscale images of the arterial wall and the extent of atherosclerotic plaques with high spatial resolution in real time. In this paper, we review recently developed image processing methods for the detection of media-adventitia and luminal borders in IVUS images acquired with different transducers operating at frequencies ranging from 20 to 45 MHz. We discuss methodological challenges, lack of diversity in reported datasets, and weaknesses of quantification metrics that make IVUS segmentation still an open problem despite all efforts. In conclusion, we call for a common reference database, validation metrics, and ground-truth definition with which new and existing algorithms could be benchmarked.

  16. Intravascular ultrasound assessment of remodelling and reference segment plaque burden in type-2 diabetic patients

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2007-01-01

    AIMS: Intravascular ultrasound (IVUS) assesses arterial remodelling by comparing the lesion external elastic membrane (EEM) with the reference segments; however, reference segments are rarely disease-free. The aim was to assess lesion and reference segment remodelling and plaque burden in patients...... with type-2 diabetes mellitus. METHODS AND RESULTS: We used pre-intervention IVUS to study 62 de novo lesions in 43 patients with type-2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal...... size [slope = -0.12 (95% CI -0.17 to -0.07); P type-2 diabetes mellitus. CONCLUSION: Lesions in type-2 diabetic patients are different from previous reports in non-diabetics. Lesions in type-2 diabetics are characterized by a large reference segment plaque burden...

  17. Influence of high-dose lipid lowering treatment compared to low-dose lipid lowering treatment on plaque composition assessed by intravascular ultrasound virtual histology in patients with ST-segment elevation acute myocardial infarction

    DEFF Research Database (Denmark)

    Egede, Rasmus; Jensen, Lisette Okkels; Hansen, Henrik Steen

    2013-01-01

    Aims: The aim of this study was to evaluate the effect of low-dose versus high-dose rosuvastatin therapy on the necrotic core content in coronary plaques of angiographic non-significant lesions as assessed by intravascular ultrasound - virtual histology. Methods and results: Eighty-seven statin...

  18. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  19. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  20. Perspectives on Imaging the Left Main Coronary Artery Using Intravascular Ultrasound and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Harry C Lowe

    2015-01-01

    Full Text Available Percutaneous Coronary Intervention (PCI for significant left main coronary artery (LMCA stenosis is increasingly being viewed as a viable alternative to Coronary Artery Bypass Grafting (CABG (1. This is leading to an expectation of increasing numbers of such procedures, with a consequent focus on both the ability to image both lesion severity, and assess more accurately the results of PCI. While there have been advances in physiologic assessment of left main severity using fractional flow reserve (FFR, imaging of the LMCA using Intravascular Ultrasound (IVUS and more recently Optical Coherence Tomography (OCT has the specific advantage of being able to provide detailed anatomical information both pre and post PCI, such that it is timely to review briefly the current status of these two imaging technologies in the context of LMCA intervention.

  1. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  2. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  3. Bioresorbable Scaffold for Treatment of Coronary Artery Lesions: Intravascular Ultrasound Results From the ABSORB Japan Trial.

    Science.gov (United States)

    Okada, Kozo; Honda, Yasuhiro; Kitahara, Hideki; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Hollak, M Brooke; Yock, Paul G; Popma, Jeffrey J; Kusano, Hajime; Cheong, Wai-Fung; Sudhir, Krishnankutty; Fitzgerald, Peter J; Kimura, Takeshi

    2018-04-09

    The aim of this study was to characterize post-procedural intravascular ultrasound (IVUS) findings in the ABSORB Japan trial, specifically stratified by the size of target coronary arteries. Despite overall noninferiority confirmed in recent randomized trials comparing bioresorbable vascular scaffolds (BVS) (Absorb BVS) and cobalt-chromium everolimus-eluting metallic stents (CoCr-EES), higher event rates of Absorb BVS have been reported with suboptimal deployment, especially in small coronary arteries. In the ABSORB Japan trial, 150 patients (2:1 randomization) were scheduled in the IVUS cohort. Small vessel was defined as mean reference lumen diameter strategy, possibly different between polymeric and metallic devices, needs to be established for bioresorbable scaffold technology. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 Absorb™ BVS) in Japanese Population [ABSORB JAPAN]; NCT01844284). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Comparison of angiography and intravascular ultrasound before and after balloon angioplasty of the femoropopliteal artery

    International Nuclear Information System (INIS)

    Lankeren, Winnifred van; Gussenhoven, Elma J.; Pieterman, Herman; Sambeek, Marc R. H. M. van; Lugt, Aad van der

    1998-01-01

    Purpose: To compare angiographic and intravascular ultrasound (IVUS) data before and after balloon angioplasty (PTA) of the femoropopliteal artery.Methods: Qualitative and quantitative analyses were performed on corresponding angiographic and IVUS levels obtained from 135 patients.Results: IVUS detected more lesions, calcified lesions, and vascular damage than angiography. Sensitivity of angiography was good for the presence of a lesion (84%), moderate for eccentric lesions (53%) and for vascular damage (52%), and poor for calcified lesions (30%). The increase in angiographic diameter stenosis was associated with a decrease in lumen area and increase in percentage area stenosis on IVUS.Conclusions: Angiography is less sensitive than IVUS for detecting lesion eccentricity, calcified lesions, and vascular damage. Presence of a lesion and amount of plaque were underestimated angiographically. Only before PTA was good agreement found between angiographic diameter stenosis and lumen size on IVUS.

  5. Development of an intravascular ultrasound elastography based on a dual-element transducer

    Science.gov (United States)

    Shih, Cho-Chiang; Chen, Pei-Yu; Ma, Teng; Zhou, Qifa; Shung, K. Kirk; Huang, Chih-Chung

    2018-04-01

    The ability to measure the elastic properties of plaques and vessels would be useful in clinical diagnoses, particularly for detecting a vulnerable plaque. This study demonstrates the feasibility of the combination of intravascular ultrasound (IVUS) and acoustic radiation force elasticity imaging for detecting the distribution of stiffness within atherosclerotic arteries ex vivo. A dual-frequency IVUS transducer with two elements was used to induce the propagation of the shear wave (by the 8.5 MHz pushing element) which could be simultaneously monitored by the 31 MHz imaging element. The wave-amplitude image and the wave-velocity image were reconstructed by measuring the peak displacement and wave velocity of shear wave propagation, respectively. System performance was verified using gelatin phantoms. The phantom results demonstrate that the stiffness differences of shear modulus of 1.6 kPa can be distinguished through the wave-amplitude and wave-velocity images. The stiffness distributions of the atherosclerotic aorta from a rabbit were obtained, for which the values of peak displacement and the shear wave velocity were 3.7 ± 1.2 µm and 0.38 ± 0.19 m s-1 for the lipid-rich plaques, and 1.0 ± 0.2 µm and 3.45 ± 0.45 m s-1 for the arterial walls, respectively. These results indicate that IVUS elasticity imaging can be used to distinguish the elastic properties of plaques and vessels.

  6. Intravascular Young's modulus reconstruction using a parametric finite element model

    NARCIS (Netherlands)

    Baldewsing, R.A.; Oomens, C.W.J.; Steen, van der A.F.W.; Yuhas, D.; Schneider, S.C.

    2003-01-01

    IntraVascular UltraSound (IVUS) elastography may be used to detect vulnerable, rupture prone plaques, which are held responsible for the majority of acute coronary syndromes. IVUS elastography accomplishes this by visualising local incremental radial strain of arteries, in so-called elastograms.

  7. Renal Sympathetic Denervation System via Intraluminal Ultrasonic Ablation: Therapeutic Intravascular Ultrasound Design and Preclinical Evaluation.

    Science.gov (United States)

    Chernin, Gil; Szwarcfiter, Iris; Bausback, Yvonne; Jonas, Michael

    2017-05-01

    To assess the safety and performance of a nonfocused and nonballooned ultrasonic (US) catheter-based renal sympathetic denervation (RDN) system in normotensive swine. RDN with the therapeutic intravascular US catheter was evaluated in 3 experiments: (i) therapeutic intravascular US RDN vs a control group of untreated animals with follow-up of 30, 45, and 90 days (n = 6; n = 12 renal arteries for each group); (ii) therapeutic intravascular US RDN vs radiofrequency (RF) RDN in the contralateral artery in the same animal (n = 2; n = 4 renal arteries); and (iii) therapeutic intravascular US RDN in a recently stent-implanted renal artery (n = 2; n = 4 renal arteries). In the first experiment, therapeutic intravascular US RDN was safe, without angiographic evidence of dissection or renal artery stenosis. Neuronal tissue vacuolization, nuclei pyknosis, and perineuronal inflammation were evident after RDN, without renal artery wall damage. Norepinephrine levels were significantly lower after therapeutic intravascular US RDN after 30, 45, and 90 days compared with the control group (200.17 pg/mg ± 63.35, 184.75 pg/mg ± 44.51, and 203.43 pg/mg ± 58.54, respectively, vs 342.42 pg/mg ± 79.97). In the second experiment, deeper neuronal ablation penetrance was found with therapeutic intravascular US RDN vs RF RDN (maximal penetrance from endothelium of 7.0 mm vs 3.5 mm, respectively). There was less damage to the artery wall after therapeutic intravascular US RDN than with RF RDN, after which edema and injured endothelium were seen. In the third experiment, denervation inside the stent-implanted segments was feasible without damage to the renal artery wall or stent. The therapeutic intravascular US system performed safely and reduced norepinephrine levels. Deeper penetrance and better preservation of vessel wall were observed with therapeutic intravascular US RDN vs RF RDN. Neuronal ablations were observed in stent-implanted renal arteries. Copyright © 2017 SIR. Published

  8. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Stéphane, E-mail: sgcarlier@hotmail.com [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Didday, Rich [INDEC Medical Systems Inc., Santa Clara, CA (United States); Slots, Tristan [Pie Medical Imaging BV, Maastricht (Netherlands); Kayaert, Peter; Sonck, Jeroen [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); El-Mourad, Mike; Preumont, Nicolas [Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Schoors, Dany; Van Camp, Guy [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium)

    2014-06-15

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization.

  9. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    International Nuclear Information System (INIS)

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-01-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization

  10. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  11. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  12. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... to study 62 de novo lesions in 41 patients with type 2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal-looking segments within 5 mm proximal and distal to the lesion. Plaque burden...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...

  13. Multidimensional segmentation of coronary intravascular ultrasound images using knowledge-based methods

    Science.gov (United States)

    Olszewski, Mark E.; Wahle, Andreas; Vigmostad, Sarah C.; Sonka, Milan

    2005-04-01

    In vivo studies of the relationships that exist among vascular geometry, plaque morphology, and hemodynamics have recently been made possible through the development of a system that accurately reconstructs coronary arteries imaged by x-ray angiography and intravascular ultrasound (IVUS) in three dimensions. Currently, the bottleneck of the system is the segmentation of the IVUS images. It is well known that IVUS images contain numerous artifacts from various sources. Previous attempts to create automated IVUS segmentation systems have suffered from either a cost function that does not include enough information, or from a non-optimal segmentation algorithm. The approach presented in this paper seeks to strengthen both of those weaknesses -- first by building a robust, knowledge-based cost function, and then by using a fully optimal, three-dimensional segmentation algorithm. The cost function contains three categories of information: a compendium of learned border patterns, information theoretic and statistical properties related to the imaging physics, and local image features. By combining these criteria in an optimal way, weaknesses associated with cost functions that only try to optimize a single criterion are minimized. This cost function is then used as the input to a fully optimal, three-dimensional, graph search-based segmentation algorithm. The resulting system has been validated against a set of manually traced IVUS image sets. Results did not show any bias, with a mean unsigned luminal border positioning error of 0.180 +/- 0.027 mm and an adventitial border positioning error of 0.200 +/- 0.069 mm.

  14. A comparison between plaque-based and vessel-based measurement for plaque component using volumetric intravascular ultrasound radiofrequency data analysis.

    Science.gov (United States)

    Shin, Eun-Seok; Garcia-Garcia, Hector M; Garg, Scot; Serruys, Patrick W

    2011-04-01

    Although percent plaque components on plaque-based measurement have been used traditionally in previous studies, the impact of vessel-based measurement for percent plaque components have yet to be studied. The purpose of this study was therefore to correlate percent plaque components derived by plaque- and vessel-based measurement using intravascular ultrasound virtual histology (IVUS-VH). The patient cohort comprised of 206 patients with de novo coronary artery lesions who were imaged with IVUS-VH. Age ranged from 35 to 88 years old, and 124 patients were male. Whole pullback analysis was used to calculate plaque volume, vessel volume, and absolute and percent volumes of fibrous, fibrofatty, necrotic core, and dense calcium. The plaque and vessel volumes were well correlated (r = 0.893, P measurement was also highly correlated with vessel-based measurement. Therefore, the percent plaque component volume calculated by vessel volume could be used instead of the conventional percent plaque component volume calculated by plaque volume.

  15. An automated approach for segmentation of intravascular ultrasound images based on parametric active contour models

    International Nuclear Information System (INIS)

    Vard, Alireza; Jamshidi, Kamal; Movahhedinia, Naser

    2012-01-01

    This paper presents a fully automated approach to detect the intima and media-adventitia borders in intravascular ultrasound images based on parametric active contour models. To detect the intima border, we compute a new image feature applying a combination of short-term autocorrelations calculated for the contour pixels. These feature values are employed to define an energy function of the active contour called normalized cumulative short-term autocorrelation. Exploiting this energy function, the intima border is separated accurately from the blood region contaminated by high speckle noise. To extract media-adventitia boundary, we define a new form of energy function based on edge, texture and spring forces for the active contour. Utilizing this active contour, the media-adventitia border is identified correctly even in presence of branch openings and calcifications. Experimental results indicate accuracy of the proposed methods. In addition, statistical analysis demonstrates high conformity between manual tracing and the results obtained by the proposed approaches.

  16. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography.

    Science.gov (United States)

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-06-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator's identification of landmarks to establish the image synchronization. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Application of intravascular ultrasound in percutaneous coronary interventional therapy

    International Nuclear Information System (INIS)

    Wang Jingping; Li Bao; An Jian; Yang Bin; Wang Zhongchao; Wang Rijun; Zhang Wutang; Lei Xinyu; Wang Huixian; Lu Lifang; Gao Yongli

    2009-01-01

    Objective: To evaluate intravascular ultrasound (IVUS)in demonstrating the characteristics of coronary plaque and in implanting the coronary stent. Methods: Before stent implantation, IVUS was used to observe the plaque character/sties(soft, fibrotic, calcified or mixed) as well as the eccentric degree in 28 patients with angiographically-proved single coronary branch lesion. The minimal luminal diameter, minimal cross-sectional area and plaque area were measured. After stent deployment the above measurements were repeated, and the location, symmetrical index and expansion of the stent were observed. Results: A total of 36 stents was implanted in 28 patients with coronary disease. After the procedure the minimal luminal diameter and the minimal cross-sectional area was increased, while the plaque area was decreased. The difference between the values before and after the stent implantation was statistically significant (P<0.01). IVUS after stent deployment found that in all cases the stent had a nice location and covered the lesion completely with no interlayer at its both ends. Excellent expansion of the stent was seen in 30 cases (83.3%). Insufficient expansion occurred in 3 cases and undesirable contact of the stent to the arterial wall was found in 3 cases (16.7%). In such circumstances, one size bigger low-compliance balloon dilatation was adopted, or the original balloon was used again with higher pressure (18-22 atm), in order to expand the stent once more, and good results accord with IVUS optimal criteria were obtained. Conclusions: IVUS can clearly demonstrate the pathological features of the coronary lesions, such as plaque type, eccentric degree, luminal diameter, cross-sectional area and plaque area, which are very helpful in guiding the selection of the proper stent before the procedure, and are also very useful in evaluating the location, expansion of the stent as well as the stent-to-wall contact condition after the procedure. (authors)

  18. Evaluation of Directional Atherectomy Studied by Intravascular Ultrasound in Femoropopliteal Artery Stenosis

    International Nuclear Information System (INIS)

    Tielbeek, Alexander V.; Vroegindeweij, Dammis; Gussenhoven, Elma J.; Buth, Jacob; Landman, Guido H.M.

    1997-01-01

    Purpose: To evaluate the role of intravascular ultrasound (IVUS) before and after directional atherectomy (DA) in the treatment of femoropopliteal artery stenosis. Methods: In 12 patients with 16 stenoses IVUS was performed before and immediately after an angiographically successful DA. This was defined as a diameter reduction (DR) ≤ 50%, which was calculated using the minimal lumen diameter compared with the diameter of a nearby 'normal' segment. In the presence of residual plaque on IVUS an additional DA was performed. Endpoints studied were DR ≤ 30% on IVUS compared with the IVUS findings of the angiographically normal reference segment, or when no additional atherosclerotic material could be removed by further DA passages. Results: Additional DA (mean 1.6 per lesion) had to be performed in all patients. Initial DA increased the cross-sectional free lumen area (FLA) from 3.8 ± 2.0 mm 2 to 8.1 ± 2.7 mm 2 (p= 0.0004). Additional DA increased FLA to 9.3 ± 2.3 mm 2 (p= 0.002) after the second passage and to 9.8 ± 2.4 mm 2 (p= 0.09) after the final DA run. The plaque area (PLA) before DA decreased from 18.1 ± 4.2 mm 2 to 15.4 ± 4.8 mm 2 (p= 0.002) after the first passage, and to 13.5 ± 5.0 mm 2 (p= 0.004) and 12.8 ± 4.4 mm 2 (p= 0.07) after the second and final DA runs, respectively. PLA of the reference segment (9.5 ± 5.7 mm 2 ) was significantly smaller (p= 0.006) than the final PLA of the treated lesion, indicating a large amount of retained plaque. As a result of DA there was an increase in the area bordered by the medial layer, i.e., the total vessel area (from 21.9 ± 4.7 mm 2 to 23.0 ± 4.7 mm 2 ), significantly in eccentric and soft lesions. On IVUS, dissection and plaque rupture after the final passage was seen in 12 of 16 stenoses; two dissections were seen on the completion angiogram. After the final passage in all stenoses except three, the DR with IVUS was ≤ 30%. Conclusion: Lumen enlargement following DA is predominantly due to plaque

  19. A study of coronary artery rotational motion with dense scale-space optical flow in intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Danilouchkine, M G; Mastik, F; Steen, A F W van der [Department of Biomedical Engineering, Erasmus Medical Center, Ee2302, PO Box 2040, 3000 CA, Rotterdam (Netherlands)], E-mail: m.danilouchkine@ErasmusMC.nl, E-mail: f.mastik@ErasmusMC.nl, E-mail: a.vandersteen@ErasmusMC.nl

    2009-03-21

    This paper describes a novel method for estimating tissue motion in two-dimensional intravascular ultrasound (IVUS) images of a coronary artery. It is based on the classical Lukas-Kanade (LK) algorithm for optical flow (OF). The OF vector field quantifies the amount of misalignment between two consecutive frames in a sequence of images. From the theoretical standpoint, two fundamental improvements are proposed in this paper. First, using a simplified representation of the vessel wall as a medium with randomly distributed scatterers, it was shown that the OF equation satisfies the integral brightness conservation law. Second, a scale-space embedding for the OF equation was derived under the assumption of spatial consistency in IVUS acquisitions. The spatial coherence is equivalent to a locally affine motion model. The latter effectively captures and appropriately describes a complex deformation pattern of the coronary vessel wall under the varying physiological conditions (i.e. pulsatile blood pressure). The accuracy of OF tracking was estimated on the tissue-mimicking phantoms subjected to the controlled amount of angular deviation. Moreover, the performance of the classical LK and proposed approach was compared using the simulated IVUS images with an atherosclerotic lesion. The experimental results showed robust and reliable performance of up to 5{sup 0} of rotation, which is within the plausible range of circumferential displacement of the coronary arteries. Subsequently, the algorithm was used to analyze vessel wall motion in 18 IVUS pullbacks from 16 patients. The in vivo experiments revealed that the motion of coronary arteries is primarily determined by the cardiac contraction.

  20. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  1. Antiatherosclerotic effects of long-term maximally intensive statin therapy after acute coronary syndrome: insights from Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin.

    Science.gov (United States)

    Puri, Rishi; Nissen, Steven E; Shao, Mingyuan; Ballantyne, Christie M; Barter, Philip J; Chapman, M John; Erbel, Raimund; Libby, Peter; Raichlen, Joel S; Uno, Kiyoko; Kataoka, Yu; Nicholls, Stephen J

    2014-11-01

    Patients with acute coronary syndromes (ACS) display diffuse coronary atheroma instability and heightened risk of early and late recurrent coronary events. We compared the long-term antiatherosclerotic efficacy of high-intensity statins in patients with ACS when compared with stable disease. Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin (SATURN) used serial intravascular ultrasound measures of coronary atheroma volume in patients treated with rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The overall effect of high-intensity statins on the change in coronary percent atheroma volume and major adverse cardiovascular events (death/nonfatal myocardial infarction/coronary revascularization) were evaluated in this post hoc analysis. When compared with non-ACS patients (n=678), patients with ACS (n=361) were younger, actively smoking, and have had a previous myocardial infarction (all P<0.001). At baseline, patients with ACS exhibited lower high-density lipoprotein cholesterol (43.5±11 versus 45.8±11 mg/dL; P=0.002), a higher apolipoprotein B: apolipoprotein A-1 ratio (0.90±0.24 versus 0.83±0.24; P<0.001) and greater percent atheroma volume (37.3±8.5% versus 35.9±8.1%; P=0.01) when compared with non-ACS patients. Despite similar achieved levels of lipid and inflammatory markers after high-intensity statin therapy, patients with ACS demonstrated greater percent atheroma volume regression than non-ACS patients (-1.46±0.14 versus -0.89±0.13; P=0.003). After propensity-weighted multivariable adjustment, baseline percent atheroma volume (P<0.001) and an ACS clinical presentation (P=0.02) independently associated with plaque regression. The 24-month major adverse cardiovascular events-free survival was similar between patients with ACS and non-ACS (90.6 versus 92.9%; P=0.25). Long-term high-intensity statin therapy caused greater plaque regression and comparable major adverse cardiovascular events rates in

  2. Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study.

    Science.gov (United States)

    Arnold, Roman; Villa, Adolfo; Gutiérrez, Hipólito; Sánchez, Pedro L; Gimeno, Federico; Fernández, Maria E; Gutiérrez, Oliver; Mota, Pedro; Sánchez, Ana; García-Frade, Javier; Fernández-Avilés, Francisco; San Román, Jose A

    2010-06-01

    We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy. Copyright 2010 Mosby, Inc. All rights reserved.

  3. Intravascular photoacoustic imaging of human coronary atherosclerosis

    Science.gov (United States)

    Jansen, Krista; van der Steen, Antonius F. W.; Springeling, Geert; van Beusekom, Heleen M. M.; Oosterhuis, J. Wolter; van Soest, Gijs

    2011-03-01

    We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. We specifically imaged lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction. An integrated intravascular photoacoustics (IVPA) and ultrasound (IVUS) catheter with an outer diameter of 1.25 mm was developed. The catheter comprises an angle-polished optical fiber adjacent to a 30 MHz single-element transducer. The ultrasonic transducer was optically isolated to eliminate artifacts in the PA image. We performed measurements on a cylindrical vessel phantom and isolated point targets to demonstrate its imaging performance. Axial and lateral point spread function widths were 110 μm and 550 μm, respectively, for PA and 89 μm and 420 μm for US. We imaged two fresh human coronary arteries, showing different stages of disease, ex vivo. Specific photoacoustic imaging of lipid content, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm.

  4. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  5. Effect of cilostazol on in-stent neointimal hyperplasia after coronary artery stenting. A quantitative coronary angiography and volumetric intravascular ultrasound study

    International Nuclear Information System (INIS)

    Min, Pil-Ki; Jung, Jae-Hun; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Shim, Won-Heum

    2007-01-01

    This study was designed to investigate the efficacy of cilostazol on the prevention of in-stent neointimal hyperplasia as measured by both quantitative coronary angiography (CAG) and volumetric intravascular ultrasound (IVUS). Fifty-nine patients (39 men, age 62 years) undergoing elective coronary stenting were randomly assigned to receive aspirin plus clopidogrel or ticlopidine (Group I, n=28, 30 lesions) or aspirin plus clopidogrel or ticlopidine plus cilostazol (Group II, n=31, 35 lesions). CAG and IVUS were performed and repeated at 6 months to assess the primary endpoints of minimal luminal diameter (MLD) and in-stent neointimal hyperplasia volume. Follow-up CAG was performed on all patients and follow-up IVUS study was available for 50 lesions in 48 patients (24 lesions in Group I, 26 in Group II). There were no significant differences in the baseline angiographic data between the 2 groups. At 6 months follow-up, in-stent MLD was 1.90±0.76 mm in Group I and 2.41±0.85 mm in Group II (p=0.006). Volumetric IVUS at 6 months demonstrated that in-stent intimal hyperplasia volume per stent length was 2.2±1.4 mm 3 /mm in Group I and 1.0±0.5 mm 3 /mm in Group II (p=0.001). Triple antiplatelet therapy including cilostazol seems to be more effective at preventing in-stent neointimal hyperplasia than a dual antiplatelet regimen. (author)

  6. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...... of volumetric VH-IVUS measurements, experienced analysts of 4 European IVUS centers performed independent analyses (in total 8,052 cross-sectional analyses) to obtain volumetric data of 40 coronary segments (length 20.0 ± 0.3 mm) from target lesions prior to percutaneous intervention that were performed...... in the setting of stable (65%) or unstable angina pectoris (35%). Geometric and compositional VH-IVUS measurements were highly correlated for the different comparisons. Overall intraclass correlation for vessel, lumen, plaque volume and plaque burden was 0.99, 0.92, 0.96, and 0.83, respectively; for fibrous...

  7. Intravascular ultrasound evaluation of JETSTREAM atherectomy removal of superficial calcium in peripheral arteries.

    Science.gov (United States)

    Maehara, Akiko; Mintz, Gary S; Shimshak, Thomas M; Ricotta, Joseph J; Ramaiah, Venkatesh; Foster, Malcolm T; Davis, Thomas P; Gray, William A

    2015-05-01

    Endovascular treatment of calcified femoral-popliteal disease is challenging. We sought to evaluate the mechanism of lumen gain when using the JETSTREAM Atherectomy System to treat calcified peripheral artery lesions. The JETSTREAM Calcium Study was a prospective, single-arm, multicentre study to evaluate the JETSTREAM Atherectomy System for severely calcified femoral-popliteal artery lesions, i.e., patients with claudication and lesions with superficial calcium >90° and >5 mm in length as determined by intravascular ultrasound (IVUS). The 2.1 mm catheter was used in this study without distal protection. Fifty-five patients underwent angiographic screening: 26 (45%) met IVUS inclusion criteria. Angiographic calcium was moderate in eight cases and severe in 14, with no available data for four cases. Visual diameter stenosis was 86±9% pre-treatment, 37±13% post atherectomy, and 10±6% post adjunctive treatment (adjunctive PTA+stenting in eight and adjunct PTA alone in 16). IVUS showed lumen area increased from 6.6±3.7 mm2 to 10.0±3.6 mm2 (p=0.001): calcium reduction was responsible for 86±23% of the lumen increase. Although the superficial calcium arc did not change (151±70° to 146±71°, p=0.83), the arc of reverberation increased (23±20° to 65±40°, p=0.006), indicating device-related modification of calcium. Adjunctive balloon angioplasty was performed in 62% of the lesions, and stent implantation in 31%. In 11 cases with adjunctive balloon dilation, the MLA increased from 7.1 (6.4, 7.8) mm2 post atherectomy to 11.9 (10.3, 13.5) mm2 post balloon (pAtherectomy System increased lumen dimensions in moderately or severely calcified femoral-popliteal lesions by removing superficial calcium without major complications.

  8. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  9. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s......We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI...... in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number...... of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared...

  10. Near-Infrared Spectroscopy Enhances Intravascular Ultrasound Assessment of Vulnerable Coronary Plaque: A Combined Pathological and In Vivo Study.

    Science.gov (United States)

    Puri, Rishi; Madder, Ryan D; Madden, Sean P; Sum, Stephen T; Wolski, Kathy; Muller, James E; Andrews, Jordan; King, Karilane L; Kataoka, Yu; Uno, Kiyoko; Kapadia, Samir R; Tuzcu, E Murat; Nissen, Steven E; Virmani, Renu; Maehara, Akiko; Mintz, Gary S; Nicholls, Stephen J

    2015-11-01

    Pathological studies demonstrate the dual significance of plaque burden (PB) and lipid composition for mediating coronary plaque vulnerability. We evaluated relationships between intravascular ultrasound (IVUS)-derived PB and arterial remodeling with near-infrared spectroscopy (NIRS)-derived lipid content in ex vivo and in vivo human coronary arteries. Ex vivo coronary NIRS and IVUS imaging was performed through blood in 116 coronary arteries of 51 autopsied hearts, followed by 2-mm block sectioning (n=2070) and histological grading according to modified American Heart Association criteria. Lesions were defined as the most heavily diseased 2-mm block per imaged artery on IVUS. IVUS-derived PB and NIRS-derived lipid core burden index (LCBI) of each block and lesion were analyzed. Block-level analysis demonstrated significant trends of increasing PB and LCBI across more complex atheroma (Ptrend <0.001 for both LCBI and PB). Lesion-based analyses demonstrated the highest LCBI and remodeling index within coronary fibroatheroma (Ptrend <0.001 and 0.02 versus all plaque groups, respectively). Prediction models demonstrated similar abilities of PB, LCBI, and remodeling index for discriminating fibroatheroma (c indices: 0.675, 0.712, and 0.672, respectively). A combined PB+LCBI analysis significantly improved fibroatheroma detection accuracy (c index 0.77, P=0.028 versus PB; net-reclassification index 43%, P=0.003), whereas further adding remodeling index did not (c index 0.80, P=0.27 versus PB+LCBI). In vivo comparisons of 43 age- and sex-matched patients (to the autopsy cohort) undergoing combined NIRS-IVUS coronary imaging yielded similar associations to those demonstrated ex vivo. Adding NIRS to conventional IVUS-derived PB imaging significantly improves the ability to detect more active, potentially vulnerable coronary atheroma. © 2015 American Heart Association, Inc.

  11. Mechanism of lumen gain with a novel rotational aspiration atherectomy system for peripheral arterial disease: examination by intravascular ultrasound.

    Science.gov (United States)

    Hassan, Ali H M; Ako, Junya; Waseda, Katsuhisa; Honda, Yasuhiro; Zeller, Thomas; Leon, Martin B; Fitzgerald, Peter J

    2010-01-01

    The purpose of this study was to evaluate the mechanism of luminal gain with a novel atheroablation system (Pathway PV) for the treatment of peripheral artery disease using intravascular ultrasound (IVUS). The atherectomy system is a rotational atherectomy device, which employs expandable rotating blades with ports that allow flushing and aspiration of the plaque material or thrombus. In this first-in-man clinical study, IVUS analysis was available in 6 patients with lower limb ischemia treated with this device. The treatment results were assessed using IVUS at pre and post atherectomy. Lumen beyond burr size (LBB) was defined as lumen gain divided by the estimated burr area determined by the burr-size. IVUS analysis was available in six patients (superficial femoral artery n=3, popliteal artery n=2, posterior tibial artery n=1). Atheroablation achieved a significant increase in lumen area (LA) (preintervention 3.9+/-0.4, postatheroablation 8.0+/-1.7 mm(2), Patherectomy device achieved significant luminal gain by debulking in the absence of vessel stretching. The LA was greater than burr-sized lumen expectancy at cross-sections along the treated segments, suggesting a complimentary role of aspiration in luminal gain in atherosclerotic peripheral artery lesions.

  12. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    Science.gov (United States)

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  13. TWO NOVEL ACM (ACTIVE CONTOUR MODEL) METHODS FOR INTRAVASCULAR ULTRASOUND IMAGE SEGMENTATION

    International Nuclear Information System (INIS)

    Chen, Chi Hau; Potdat, Labhesh; Chittineni, Rakesh

    2010-01-01

    One of the attractive image segmentation methods is the Active Contour Model (ACM) which has been widely used in medical imaging as it always produces sub-regions with continuous boundaries. Intravascular ultrasound (IVUS) is a catheter based medical imaging technique which is used for quantitative assessment of atherosclerotic disease. Two methods of ACM realizations are presented in this paper. The gradient descent flow based on minimizing energy functional can be used for segmentation of IVUS images. However this local operation alone may not be adequate to work with the complex IVUS images. The first method presented consists of basically combining the local geodesic active contours and global region-based active contours. The advantage of combining the local and global operations is to allow curves deforming under the energy to find only significant local minima and delineate object borders despite noise, poor edge information and heterogeneous intensity profiles. Results for this algorithm are compared to standard techniques to demonstrate the method's robustness and accuracy. In the second method, the energy function is appropriately modified and minimized using a Hopfield neural network. Proper modifications in the definition of the bias of the neurons have been introduced to incorporate image characteristics. The method overcomes distortions in the expected image pattern, such as due to the presence of calcium, and employs a specialized structure of the neural network and boundary correction schemes which are based on a priori knowledge about the vessel geometry. The presented method is very fast and has been evaluated using sequences of IVUS frames.

  14. The Precise Determination of Vascular Lumen and Stent Diameters: Correlation Among Calibrated Angiography, Intravascular Ultrasound, and Pressure-Fixed Specimens

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Hoppe, Martin; Nahrstedt, Christoph; Barth, Klemens H.; Wagner, H. Joachim; Klose, Klaus J.

    1997-01-01

    Purpose: Luminal diameters measured in vivo by calibrated-catheter angiography and by intravascular ultrasound were correlated with those obtained from pressure-fixed histologic cross-sections to determine the accuracy of both methods. Methods: Angiographic and endosonographic diameter measurements were performed in the center of stents placed in the iliac arteries of 10 miniature pigs and were compared with luminal and stent diameters in postmortem, pressure-fixed, histologic cross-sections from identical locations. Results: Compared with histologic diameters, magnification-corrected angiographic measurements still magnified vascular luminal diameters by 0.7 ± 0.71 mm (r= 0.41, Pearson; p 0.5, Wilcoxon, matched pairs). Similarly, stent diameters correlated well between endosonographic and histologic measurements (r= 0.91; p= 0.002), and less well between angiographic and histologic diameters (r= 0.62; p= 0.002). Conclusion: Since calibrated angiography still overestimates vascular lumina, endosonography is the preferred technique for accurate in vivo measurements

  15. Intravascular ultrasound and angiographic demonstration of left main stem thrombus-high-risk presentation in a young adult with anabolic steroid abuse.

    Science.gov (United States)

    Garg, Pankaj; Davis, Gershan; Wilson, John Ian; Sivananthan, Mohan

    2010-01-01

    We present a case of acute myocardial infarction in a young adult with a history of anabolic steroid abuse. On diagnostic coronary angiography and intravascular ultrasound, he was found to have a distal left main stem thrombus extending into the proximal left anterior descending artery and a large intermediate vessel. As he was hemodynamically stable and pain-free, he was managed conservatively with triple antiplatelet therapy (aspirin, clopidogrel, and abciximab). This was also to avoid the risk of 'wiring the vessel,' especially if there was underlying dissection. Repeat angiography a few weeks later showed complete thrombus resolution. This is the first reported case of extensive left main stem thrombus in a young patient with anabolic steroid abuse. Management of such cases is not straightforward and our case highlights one approach to both diagnosis and treatment.

  16. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis.......Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesions...

  17. High-intensity focused ultrasound sonothrombolysis: the use of perfluorocarbon droplets to achieve clot lysis at reduced acoustic power.

    Science.gov (United States)

    Pajek, Daniel; Burgess, Alison; Huang, Yuexi; Hynynen, Kullervo

    2014-09-01

    The purpose of this study was to evaluate use of intravascular perfluorocarbon droplets to reduce the sonication power required to achieve clot lysis with high-intensity focused ultrasound. High-intensity focused ultrasound with droplets was initially applied to blood clots in an in vitro flow apparatus, and inertial cavitation thresholds were determined. An embolic model for ischemic stroke was used to illustrate the feasibility of this technique in vivo. Recanalization with intravascular droplets was achieved in vivo at 24 ± 5% of the sonication power without droplets. Recanalization occurred in 71% of rabbits that received 1-ms pulsed sonications during continuous intravascular droplet infusion (p = 0.041 vs controls). Preliminary experiments indicated that damage was confined to the ultrasonic focus, suggesting that tolerable treatments would be possible with a more tightly focused hemispheric array that allows the whole focus to be placed inside of the main arteries in the human brain. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  19. Intravascular Large B-Cell Lymphoma Presenting with Diffuse Gallbladder Wall Thickening: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Sayf Al-Katib

    2018-01-01

    Full Text Available Intravascular large B-cell lymphoma is a rare subtype of extranodal diffuse B-cell lymphoma characterized by proliferation of neoplastic cells within the lumen of small and medium sized vessels. Clinical and imaging findings are nebulous as the intravascular subtype of lymphoma can involve a multitude of organs. Involvement of the gallbladder is extremely uncommon, and imaging findings can be easily confused for more prevalent pathologies. We report a case of intravascular large B-cell lymphoma in an 83-year-old male and review clinical presentation and imaging findings on CT, ultrasound, hepatobiliary iminodiacetic acid (HIDA scan, and MRI. It is important for the radiologist to know about this disease as the imaging findings are atypical of other types of lymphoma, and this may lead to a delay in diagnosis and treatment.

  20. Augmentation of limb perfusion and reversal of tissue ischemia produced by ultrasound-mediated microbubble cavitation.

    Science.gov (United States)

    Belcik, J Todd; Mott, Brian H; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J; Ammi, Azzdine; Linden, Joel M; Lindner, Jonathan R

    2015-04-01

    Ultrasound can increase tissue blood flow, in part, through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation and sought to characterize the biological mediators. Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in nonischemic mice after unilateral 10-minute exposure to intermittent ultrasound alone (mechanical index, 0.6 or 1.3) or ultrasound with lipid microbubbles (2×10(8) IV). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (Pultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3- and 10-fold higher than control for mechanical index 0.6 and 1.3, respectively; Pultrasound and microbubbles by 70% (Pultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40%-50% reduction in flow), ultrasound (mechanical index, 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control nonischemic limb. Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of endothelial nitric oxide synthase. © 2015 American Heart Association, Inc.

  1. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  2. Intravascular photoacoustic imaging: a new tool for vulnerable plaque identification.

    Science.gov (United States)

    Jansen, Krista; van Soest, Gijs; van der Steen, Antonius F W

    2014-06-01

    The vulnerable atherosclerotic plaque is believed to be at the root of the majority of acute coronary events. Even though the exact origins of plaque vulnerability remain elusive, the thin-cap fibroatheroma, characterized by a lipid-rich necrotic core covered by a thin fibrous cap, is considered to be the most prominent type of vulnerable plaque. No clinically available imaging technique can characterize atherosclerotic lesions to the extent needed to determine plaque vulnerability prognostically. Intravascular photoacoustic imaging (IVPA) has the potential to take a significant step in that direction by imaging both plaque structure and composition. IVPA is a natural extension of intravascular ultrasound that adds tissue type specificity to the images. IVPA utilizes the optical contrast provided by the differences in the absorption spectra of plaque components to image composition. Its capability to image lipids in human coronary atherosclerosis has been shown extensively ex vivo and has recently been translated to an in vivo animal model. Other disease markers that have been successfully targeted are calcium and inflammatory markers, such as macrophages and matrix metalloproteinase; the latter two through application of exogenous contrast agents. By simultaneously displaying plaque morphology and composition, IVPA can provide a powerful prognostic marker for disease progression, and as such has the potential to transform the current practice in percutaneous coronary intervention. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesions...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  4. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination....... All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure....... revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along...

  5. Detection of attenuated plaque in stable angina with 64-multidetector computed tomography: a comparison with intravascular ultrasound.

    Science.gov (United States)

    Jinzaki, Masahiro; Okabe, Teruo; Endo, Ayaka; Kawamura, Akio; Koga, Seiko; Yamada, Minoru; Fukuda, Keiichi; Kuribayashi, Sachio

    2012-01-01

    To clarify multidetector computed tomography (MDCT) findings of attenuated plaque detected by intravascular ultrasound (IVUS). One hundred and fifty-four patients with stable angina underwent MDCT before IVUS. The attenuated plaque was identified in the targeted artery with IVUS, and the same artery was analyzed with MDCT for the presence of a high density area (HDA) >130 Hounsfield units (HU), and a low density area (LDA) HDA in attenuated plaque was compared with that in calcified plaque. Ten attenuated plaques and 15 calcified plaques were identified in 9 of 154 patients (males=9, 66.2 ± 9.5 years). Eight of the 10 attenuated plaques and all 15 calcified plaques were accompanied with a HDA on MDCT. The HDA ranged from 174 to 667 HU (mean 389.0 ± 148.3 HU) in the 8 attenuated plaques, and from 545 to 1,205 HU (mean 920.9 ± 215.9 HU) in 15 calcified plaques. There was a significant difference in CT density of the HDA between the attenuated and calcified plaque (PHDA. MDCT has the ability to demonstrate attenuated plaque as the combination of HDA (approximately 400 HU on average) and LDA HDA can be differentiated from calcified plaque by its lower CT density value.

  6. Molecular imaging with targeted contrast ultrasound.

    Science.gov (United States)

    Piedra, Mark; Allroggen, Achim; Lindner, Jonathan R

    2009-01-01

    Molecular imaging with contrast-enhanced ultrasound uses targeted microbubbles that are retained in diseased tissue. The resonant properties of these microbubbles produce acoustic signals in an ultrasound field. The microbubbles are targeted to diseased tissue by using certain chemical constituents in the microbubble shell or by attaching disease-specific ligands such as antibodies to the microbubble. In this review, we discuss the applications of this technique to pathological states in the cerebrovascular system including atherosclerosis, tumor angiogenesis, ischemia, intravascular thrombus, and inflammation. Copyright 2009 S. Karger AG, Basel.

  7. Ultrasound imaging with a micromotor; Micromotor ni yoru choonpa imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, O.; Salimuzzaman, M.; Matani, A.; Chihara, K. [Nara Institute of Science and Technology, Nara (Japan); Asao, M. [Osaka National Hospital, Osaka (Japan)

    1998-03-01

    This paper describes a new ultrasound intravascular imaging system. In this system, an ultrasound probe consists of a micromotor, an ultrasound reflecting mirror attached with the micromotor and an ultrasound transducer. Ultrasound is scanned radially by a micromotor instead of a rotation transmitting wire and the rotation of the micromotor is performed and controlled by an external magnetic field. This ultrasound imaging system with a micromotor was applied to observe the inside of blood vessels through in vitro experiments. The preliminary results suggest that this system has the sufficient ability to define the blood vessel morphology and that the simple image processing enhances signal-to-noise ratio of the reconstructed image. 12 refs., 5 figs.

  8. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. 21 CFR 870.3375 - Cardiovascular intravascular filter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular intravascular filter. 870.3375... Cardiovascular intravascular filter. (a) Identification. A cardiovascular intravascular filter is an implant that... and Revision of 2/12/90 (K90-1)” and (ii) “Guidance for Cardiovascular Intravascular Filter 510(k...

  10. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  11. Intravascular malignant lymphomatosis

    International Nuclear Information System (INIS)

    Martin-Duverneuil, N.; Lafitte, F.; Chiras, J.; Mokhtari, K.; Behin, A.; Hoang-Xuan, K.

    2002-01-01

    Intravascular malignant lymphomatosis is a rare and probably often overlooked disease characterised by massive intravascular proliferation of lymphoid cells, usually with a poor prognosis. CT and MRI appearances are nonspecific; the most suggestive finding being both asymmetrical, bilateral, contrast enhancing high-signal areas on T2 weighting and infarct-like lesions of the cortex and basal ganglia. We report two patients with previously unreported dural and spinal cord involvement. (orig.)

  12. Intravascular malignant lymphomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Duverneuil, N.; Lafitte, F.; Chiras, J. [Service de Neuroradiologie Charcot, Batiment Babinski, Hopital de la Salpetriere, 75013 Paris (France); Mokhtari, K. [Service de Neuropathologie, Hopital de la Salpetriere, 75013 Paris (France); Behin, A.; Hoang-Xuan, K. [Departement de Neurologie, Hopital de la Salpetriere, 75013 Paris (France)

    2002-09-01

    Intravascular malignant lymphomatosis is a rare and probably often overlooked disease characterised by massive intravascular proliferation of lymphoid cells, usually with a poor prognosis. CT and MRI appearances are nonspecific; the most suggestive finding being both asymmetrical, bilateral, contrast enhancing high-signal areas on T2 weighting and infarct-like lesions of the cortex and basal ganglia. We report two patients with previously unreported dural and spinal cord involvement. (orig.)

  13. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    Science.gov (United States)

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  14. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  15. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan); Kishimoto, Junichi; Iwata, Naoki [Tottori University Hospital, Division of Clinical Radiology, Yonago (Japan)

    2015-09-15

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  16. Influence of ezetimibe in addition to high-dose atorvastatin therapy on plaque composition in patients with ST-segment elevation myocardial infarction assessed by serial Intravascular ultrasound with iMap: the OCTIVUS trial*

    DEFF Research Database (Denmark)

    Hougaard, Mikkel; Hansen, Henrik Steen; Thayssen, Per

    2017-01-01

    Background: The aim of this study was to examine the influence of ezetimibe in addition to atorvastatin on plaque composition in patients with first-time ST-segment Elevation Myocardial Infarction treated with primary percutaneous intervention. Methods: Eighty-seven patients were randomized ( 1: 1......) to ezetimibe 10mg or placebo in addition to Atorvastatin 80 mg. Intravascular ultrasound with iMap was performed at baseline and after 12 months in a non-infarctrelated artery. Primary endpoint was change in necrotic core (NC). Secondary endpoints were total atheroma volume (TAV) and percentage atheroma volume.......3 +/- 9.4% to 42.2 +/- 10.7 p - 0.07),p - 0.91 between groups. Conclusions: Ezetimibe in addition to atorvastatin therapy did not influence NC content, but was associated with regression of coronary atherosclerosis. (C) 2016 Elsevier Inc. All rights reserved....

  17. Characteristics of virtual histology-intravascular unltrasound of infarction-related artery atheromatous plaque and pregnancy-associated plasma protein A level: a correlation study

    International Nuclear Information System (INIS)

    Chen Shaobo; Jiang Tiemin; Liang Guoqing; Zhao Jihong; Li Yuming

    2011-01-01

    Objective: To observe the characteristics of virtual histology-intravascular ultrasound (VH-IVUS) in 70 patients with acute ST segment elevated type myocardial infarction (AMI), the findings were compared with that in 70 patients with stable angina (control group), and to analyze the correlation between VH-IVUS characteristics and pregnancy-associated plasma protein A (PAPPA) level. Methods: Seventy patients with ST segment elevated AMI and 70 patients with stable angina, who received percutaneous coronary artery intervention and were encountered from Jan. 2008 to Dec. 2009, were involved in this study. After coronary angiography was completed,the plasma was aspirated from culprit coronary artery with ZEEK catheter. Then, IVUS examination to culprit lesion was carried out and grayscale and VH data were stored. The characteristics of VH-IVUS of culprit atheromatous plaque were observed and its correlation with PAPPA was analyzed. Results: The difference in age,gender, hypertension, smoking, diabetes mellitus and hyperlipidemia between two groups was of no statistical significance, but statistically significant difference in VH-IVUS characteristics of the atheromatous plaque existed between two groups, more fibro-fatty tissue and necrotic tissue with less dense calcium were seen in AMI group. The ratio of necrotic tissue area to calcified tissue area was (3.62±1.46) in AMI group and(7.18±2.53) in control group (P<0.01). PAPPA in AMI group was significantly higher than that in control group (P<0.01). Parameters of VH-IVUS in AMI group were highly correlated with PAPPA (P<0.05 or P<0.01). Conclusion: The characteristics of virtual histology-intravascular ultrasound of infarction-related artery atheromatous plaque include more necrotic tissue, higher ratio of necrotic tissue area to calcified tissue area and a closer correlation with PAPPA. (authors)

  18. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  19. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  20. Determination of Stent Stenosis: An In Vivo Experimental Comparison of Intravascular Ultrasound and Angiography with Histology

    International Nuclear Information System (INIS)

    Schuermann, Karl; Vorwerk, Dierk; Uppenkamp, Robert; Klosterhalfen, Bernd; Buecker, Arno; Guenther, Rolf W.

    1998-01-01

    Purpose: To compare intravascular ultrasound (IVUS) and angiography with histology in determining the degree of stent stenosis in an in vivo experiment. Methods: In 16 sheep, a total of 64 stents were implanted into the external iliac arteries. Two stents were inserted on either side. Patency was followed by angiography and IVUS. Four types of stent were used: two Dacron-covered (Cragg Endopro and heparinized Cragg Endopro) and two non-covered (Cragg and Memotherm stents). Eight animals were killed after 1 month, eight others after 6 months. Histological sections were prepared from the stented vessels. Measurements of the patent and total stent diameters determined by IVUS, angiography, and histology were compared. Results: Correlation between IVUS and angiography was 0.75, between IVUS and histology 0.77, and between angiography and histology 0.85. A mean stent stenosis of 17 ± 11% (range 0-51%) was found on angiography, of 10 ± 11% (0-46%) on IVUS, and of 20 ± 11% (4%-49%) on histology. In comparison with histology, IVUS underestimated the degree of stenosis by 10 ± 8%, and angiography underestimated it by 3 ± 6%. Resolution of IVUS was calculated to be about 0.35 mm and that of angiography to be about 0.15 mm. Conclusion: Under experimental conditions, IVUS was not superior to angiography in determining the degree of stent stenosis in long-segment stenoses of iliac artery stents, when measurements were correlated with histology. Angiography is sufficient for following the patency of iliac artery stents

  1. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  2. Catheter design optimization for practical intravascular photoacoustic imaging (IVPA) of vulnerable plaques

    Science.gov (United States)

    Iskander-Rizk, Sophinese; Wu, Min; Springeling, Geert; Mastik, Frits; Beurskens, Robert H. S. H.; van der Steen, Antonius F. W.; van Soest, Gijs

    2018-02-01

    Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium.

  3. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    Science.gov (United States)

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  4. Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients.

    Science.gov (United States)

    Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A

    2010-05-01

    Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively

  5. Intraarterial Ultrasound in Pancreatic Cancer: Feasibility Study and Preliminary Results

    International Nuclear Information System (INIS)

    Larena-Avellaneda, Axel; Timm, Stephan; Kickuth, Ralph; Kenn, Werner; Steger, Ulrich; Jurowich, Christian; Germer, Christoph-Thomas

    2010-01-01

    Despite technological advances in computed tomography (CT) and magnetic resonance imaging, the involvement of the celiac or mesenteric artery in pancreatic cancer remains uncertain in many cases. Infiltration of these vessels is important in making decisions about therapy choices but often can only be definitively determined through laparotomy. Local (intraarterial) ultrasound may increase diagnostic accuracy. Using the Volcano intravascular ultrasound (IVUS) system, we applied a transfemoral method to scan the celiac and mesenteric arteries directly intraarterial. This technique was used in five patients with suspected pancreatic cancer. Technical success was achieved in all cases. In one case, a short dissection of the mesenteric artery occurred but could be managed interventionally. In tumors that did not contact with the vessels, IVUS was unable to display the tissue pathology. Our main interest was the infiltration of the arteries. In one case, infiltration was certain in the CT scan but uncertain in two patients. In the latter two cases, IVUS correctly predicted infiltration in one and freedom from tumor in the other case. In our preliminary study, IVUS correctly predicted arterial infiltration in all cases. IVUS did not provide new information when the tumor was far away from the vessel. Compared with IVUS in the portal vein, the information about the artery is more detailed, and the vessel approach is easier. These results encouraged us to design a prospective study to evaluate the sensitivity and specificity of this method.

  6. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  7. Variability and accuracy of coronary CT angiography including use of iterative reconstruction algorithms for plaque burden assessment as compared with intravascular ultrasound - an ex vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Schlett, Christopher L.; Maurovich-Horvat, Pal; Scheffel, Hans; Engel, Leif-Christopher; Karolyi, Mihaly; Hoffmann, Udo [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Maehara, Akiko; Ma, Shixin; Mintz, Gary S. [Columbia University Medical Center, Cardiovascular Research Foundation, New York, NY (United States)

    2012-10-15

    To systematically assess inter-technique and inter-/intra-reader variability of coronary CT angiography (CTA) to measure plaque burden compared with intravascular ultrasound (IVUS) and to determine whether iterative reconstruction algorithms affect variability. IVUS and CTA data were acquired from nine human coronary arteries ex vivo. CT images were reconstructed using filtered back projection (FBPR) and iterative reconstruction algorithms: adaptive-statistical (ASIR) and model-based (MBIR). After co-registration of 284 cross-sections between IVUS and CTA, two readers manually delineated the cross-sectional plaque area in all images presented in random order. Average plaque burden by IVUS was 63.7 {+-} 10.7% and correlated significantly with all CTA measurements (r = 0.45-0.52; P < 0.001), while CTA overestimated the burden by 10 {+-} 10%. There were no significant differences among FBPR, ASIR and MBIR (P > 0.05). Increased overestimation was associated with smaller plaques, eccentricity and calcification (P < 0.001). Reproducibility of plaque burden by CTA and IVUS datasets was excellent with a low mean intra-/inter-reader variability of <1/<4% for CTA and <0.5/<1% for IVUS respectively (P < 0.05) with no significant difference between CT reconstruction algorithms (P > 0.05). In ex vivo coronary arteries, plaque burden by coronary CTA had extremely low inter-/intra-reader variability and correlated significantly with IVUS measurements. Accuracy as well as reader reliability were independent of CT image reconstruction algorithm. (orig.)

  8. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  9. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  10. High speed intravascular photoacoustic imaging of atherosclerotic arteries (Conference Presentation)

    Science.gov (United States)

    Piao, Zhonglie; Ma, Teng; Qu, Yueqiao; Li, Jiawen; Yu, Mingyue; He, Youmin; Shung, K. Kirk; Zhou, Qifa; Kim, Chang-Seok; Chen, Zhongping

    2016-02-01

    Cardiovascular disease is the leading cause of death in the industrialized nations. Accurate quantification of both the morphology and composition of lipid-rich vulnerable atherosclerotic plaque are essential for early detection and optimal treatment in clinics. In previous works, intravascular photoacoustic (IVPA) imaging for detection of lipid-rich plaque within coronary artery walls has been demonstrated in ex vivo, but the imaging speed is still limited. In order to increase the imaging speed, a high repetition rate laser is needed. In this work, we present a high speed integrated IVPA/US imaging system with a 500 Hz optical parametric oscillator laser at 1725 nm. A miniature catheter with 1.0 mm outer diameter was designed with a 200 μm multimode fiber and an ultrasound transducer with 45 MHz center frequency. The fiber was polished at 38 degree and enclosed in a glass capillary for total internal reflection. An optical/electrical rotary junction and pull-back mechanism was applied for rotating and linearly scanning the catheter to obtain three-dimensional imaging. Atherosclerotic rabbit abdominal aorta was imaged as two frame/second at 1725 nm. Furthermore, by wide tuning range of the laser wavelength from 1680 nm to 1770 nm, spectroscopic photoacoustic analysis of lipid-mimicking phantom and an human atherosclerotic artery was performed ex vivo. The results demonstrated that the developed IVPA/US imaging system is capable for high speed intravascular imaging for plaque detection.

  11. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  12. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    Science.gov (United States)

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  13. Prediction of postpercutaneous coronary intervention myocardial infarction: insights from intravascular imaging, coronary flow, and biomarker evaluation.

    Science.gov (United States)

    Hoole, Stephen P; Hernández-Sánchez, Jules; Brown, Adam J; Giblett, Joel P; Bennett, Martin R; West, Nick E J

    2018-05-01

    Percutaneous coronary intervention-induced myocardial infarction (PMI) has prognostic significance. Identifying patients at high risk for PMI is desirable as it may alter strategy and facilitate early preventative therapy. We therefore sought to establish whether preprocedural demographic, interventional (plaque characteristics and coronary microcirculatory function), and inflammatory, endothelial damage, and platelet-derived biomarker data could predict the risk of PMI. We performed target vessel pressure wire to assess fractional flow reserve, index of microcirculatory resistance (IMR) and coronary flow reserve, plaque characterization by virtual histology intravascular ultrasound, and assayed peripheral biomarkers before uncomplicated PCI in 88 patients. We then analyzed post-PCI cardiac troponin level to adjudicate PMI based on the third universal definition of myocardial infarction. Overall incidence of PMI was 27%. Women [10/15 (66%) vs. 14/73 (19%), PPMI. Preprocedural coronary flow reserve was lower in individuals with a subsequent PMI (1.8±1.2 vs. 2.1±1.3. P=0.03), and patients with higher pre-PCI IMR were more likely to sustain PMI [IMR>22: 10/23 (44%) vs. ≤22: 14/65 (22%), P=0.04], although neither was predictive after multivariate analysis. Plaque characterization by virtual histology intravascular ultrasound did not discriminate those at risk of PMI. However, peripheral venous interleukin (IL)-18 and IL-8 levels were independently negatively and positively associated with PMI, respectively. Women and those with low BMI, particularly when associated with high IL-8 and low IL-18 levels, appear to be at increased risk of PMI.

  14. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.

    Science.gov (United States)

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  15. Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies.

    Science.gov (United States)

    Sanz-Requena, Roberto; Moratal, David; García-Sánchez, Diego Ramón; Bodí, Vicente; Rieta, José Joaquín; Sanchis, Juan Manuel

    2007-03-01

    Intravascular ultrasound (IVUS) imaging is used along with X-ray coronary angiography to detect vessel pathologies. Manual analysis of IVUS images is slow and time-consuming and it is not feasible for clinical purposes. A semi-automated method is proposed to generate 3D reconstructions from IVUS video sequences, so that a fast diagnose can be easily done, quantifying plaque length and severity as well as plaque volume of the vessels under study. The methodology described in this work has four steps: a pre-processing of IVUS images, a segmentation of media-adventitia contour, a detection of intima and plaque and a 3D reconstruction of the vessel. Preprocessing is intended to remove noise from the images without blurring the edges. Segmentation of media-adventitia contour is achieved using active contours (snakes). In particular, we use the gradient vector flow (GVF) as external force for the snakes. The detection of lumen border is obtained taking into account gray-level information of the inner part of the previously detected contours. A knowledge-based approach is used to determine which level of gray corresponds statistically to the different regions of interest: intima, plaque and lumen. The catheter region is automatically discarded. An estimate of plaque type is also given. Finally, 3D reconstruction of all detected regions is made. The suitability of this methodology has been verified for the analysis and visualization of plaque length, stenosis severity, automatic detection of the most problematic regions, calculus of plaque volumes and a preliminary estimation of plaque type obtaining for automatic measures of lumen and vessel area an average error smaller than 1mm(2) (equivalent aproximately to 10% of the average measure), for calculus of plaque and lumen volume errors smaller than 0.5mm(3) (equivalent approximately to 20% of the average measure) and for plaque type estimates a mismatch of less than 8% in the analysed frames.

  16. Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy.

    Science.gov (United States)

    Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong

    2017-07-01

    Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (Pelectrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE remain to be determined.

  17. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  18. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

    Directory of Open Access Journals (Sweden)

    Sara Pourshahidi

    2008-04-01

    Full Text Available

    Background and aims. Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections.

    Materials and methods. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test.

    Results. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127 and between right and left injection sites (P = 0.778.

    Conclusion. According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  19. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  20. NIRS and IVUS for characterization of atherosclerosis in patients undergoing coronary angiography

    NARCIS (Netherlands)

    Brugaletta, Salvatore; Garcia-Garcia, Hector M.; Serruys, Patrick W.; de Boer, Sanneke; Ligthart, Jurgen; Gomez-Lara, Josep; Witberg, Karen; Diletti, Roberto; Wykrzykowska, Joanna; van Geuns, Robert-Jan; Schultz, Carl; Regar, Evelyn; Duckers, Henricus J.; van Mieghem, Nicolas; de Jaegere, Peter; Madden, Sean P.; Muller, James E.; van der Steen, Antonius F. W.; van der Giessen, Wim J.; Boersma, Eric

    2011-01-01

    The aim of this study was to compare the findings of near-infrared spectroscopy (NIRS), intravascular ultrasound (IVUS) virtual histology (VH), and grayscale IVUS obtained in matched coronary vessel segments of patients undergoing coronary angiography. Intravascular ultrasound VH has been developed

  1. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  2. Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy.

    Science.gov (United States)

    Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M

    2018-01-01

    Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.

  3. Assessing intravascular fluid status

    African Journals Online (AJOL)

    The assessment of intravascular fluid volume is a difficult undertaking in both the intensive care unit and theatre situation ... equally applicable to pulmonary capillary wedge pressure. .... airway pressure, the more difficult it becomes to interpret ...

  4. Disseminated intravascular coagulation (DIC)

    Science.gov (United States)

    ... Jr, Silberstein LE, et al, eds. Hematology: Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 141. Thachil J, Toh CH. Current concepts in the management of disseminated intravascular coagulation. Thromb Res . 2012;129 ...

  5. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Novel approaches to the management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; de Jonge, E.; van der Poll, T.; ten Cate, H.

    2000-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. We addressed the issue of whether there is evidence that this fibrin deposition contributes to multiple organ

  7. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated the...

  8. Validating Intravascular Imaging with Serial Optical Coherence Tomography and Confocal Fluorescence Microscopy.

    Science.gov (United States)

    Tardif, Pier-Luc; Bertrand, Marie-Jeanne; Abran, Maxime; Castonguay, Alexandre; Lefebvre, Joël; Stähli, Barbara E; Merlet, Nolwenn; Mihalache-Avram, Teodora; Geoffroy, Pascale; Mecteau, Mélanie; Busseuil, David; Ni, Feng; Abulrob, Abedelnasser; Rhéaume, Éric; L'Allier, Philippe; Tardif, Jean-Claude; Lesage, Frédéric

    2016-12-15

    Atherosclerotic cardiovascular diseases are characterized by the formation of a plaque in the arterial wall. Intravascular ultrasound (IVUS) provides high-resolution images allowing delineation of atherosclerotic plaques. When combined with near infrared fluorescence (NIRF), the plaque can also be studied at a molecular level with a large variety of biomarkers. In this work, we present a system enabling automated volumetric histology imaging of excised aortas that can spatially correlate results with combined IVUS/NIRF imaging of lipid-rich atheroma in cholesterol-fed rabbits. Pullbacks in the rabbit aortas were performed with a dual modality IVUS/NIRF catheter developed by our group. Ex vivo three-dimensional (3D) histology was performed combining optical coherence tomography (OCT) and confocal fluorescence microscopy, providing high-resolution anatomical and molecular information, respectively, to validate in vivo findings. The microscope was combined with a serial slicer allowing for the imaging of the whole vessel automatically. Colocalization of in vivo and ex vivo results is demonstrated. Slices can then be recovered to be tested in conventional histology.

  9. Effector CD4+ T cells recognize intravascular antigen presented by patrolling monocytes.

    Science.gov (United States)

    Westhorpe, Clare L V; Norman, M Ursula; Hall, Pam; Snelgrove, Sarah L; Finsterbusch, Michaela; Li, Anqi; Lo, Camden; Tan, Zhe Hao; Li, Songhui; Nilsson, Susan K; Kitching, A Richard; Hickey, Michael J

    2018-02-21

    Although effector CD4 + T cells readily respond to antigen outside the vasculature, how they respond to intravascular antigens is unknown. Here we show the process of intravascular antigen recognition using intravital multiphoton microscopy of glomeruli. CD4 + T cells undergo intravascular migration within uninflamed glomeruli. Similarly, while MHCII is not expressed by intrinsic glomerular cells, intravascular MHCII-expressing immune cells patrol glomerular capillaries, interacting with CD4 + T cells. Following intravascular deposition of antigen in glomeruli, effector CD4 + T-cell responses, including NFAT1 nuclear translocation and decreased migration, are consistent with antigen recognition. Of the MHCII + immune cells adherent in glomerular capillaries, only monocytes are retained for prolonged durations. These cells can also induce T-cell proliferation in vitro. Moreover, monocyte depletion reduces CD4 + T-cell-dependent glomerular inflammation. These findings indicate that MHCII + monocytes patrolling the glomerular microvasculature can present intravascular antigen to CD4 + T cells within glomerular capillaries, leading to antigen-dependent inflammation.

  10. Non-invasive Estimation of Pressure Changes using 2-D Vector Velocity Ultrasound: An Experimental Study with In-Vivo Examples

    DEFF Research Database (Denmark)

    Olesen, Jacob Bjerring; Villagómez Hoyos, Carlos Armando; Møller, Niclas Dechau

    2018-01-01

    and at the aortic valve of two healthy volunteers. Ultrasound measurements were performed using the experimental scanner SARUS, in combination with an 8MHz linear array transducer for experimental scans and a carotid scan, whereas a 3.5MHz phased array probe was employed for a scan of an aortic valve. Measured 2-D......A non-invasive method for estimating intravascular pressure changes using 2-D vector velocity is presented. The method was first validated on computational fluid dynamics (CFD) data, and with catheter measurements on phantoms. Hereafter, the method was tested in-vivo at the carotid bifurcation...

  11. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  13. Conceptual source design and dosimetric feasibility study for intravascular treatment: a proposal for intensity modulated brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Si Yong; Han, Eun Young; Palta, Jatinder R. [College of Medicine, Florida Univ., Florida (United States); Ha, Sung W. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2003-06-01

    To propose a conceptual design of a novel source for intensity modulated brachytherapy. The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a {sub 90}Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quarter of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.

  14. Conceptual source design and dosimetric feasibility study for intravascular treatment: a proposal for intensity modulated brachytherapy

    International Nuclear Information System (INIS)

    Kim, Si Yong; Han, Eun Young; Palta, Jatinder R.; Ha, Sung W.

    2003-01-01

    To propose a conceptual design of a novel source for intensity modulated brachytherapy. The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a 90 Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quarter of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter

  15. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  16. Intravascular brachytherapy in prevention of the secondary restenosis angioplasty transluminal coronaries

    International Nuclear Information System (INIS)

    Mejia, S.

    2001-01-01

    The radiotherapy coronary intravascular has demonstrated in a convincing way in clinical and experimental studies that produces a favorable decrease of the restenosis process. There is enough evidence to define this technique as the main current therapeutic option in the handling of the reestenosis intra stent. Accumulated experience exists of up to 3 years in patient's treaties with radiation gamma and multiple studies in several centers that demonstrate similar benefits with issuing beta. The present articulates it revises a series of radiotherapy systems and makes a setting a day on the employment of the brachytherapy intravascular in cardiologic patient

  17. Intravascular Ultrasound

    Science.gov (United States)

    ... Rounds Seminar Series & Daily Conferences Fellowships and Residencies School of Perfusion Technology Education Resources Library & Learning Resource Center CME Resources THI Journal THI Cardiac Society Register for the Cardiac Society ...

  18. Disseminated intravascular and intracardiac thrombosis after cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2017-01-01

    Full Text Available Massive intracardiac and intravascular thrombosis is a rare complication following cardiopulmonary bypass (CPB. Most of the cases of the disseminated thrombosis have been reported in patients undergoing complex cardiac surgeries and those receiving antifibrinolytic agents during CPB. We report the occurrence of disseminated intravascular and intracardiac thrombosis after CPB in a patient undergoing mitral valve replacement in which no antifibrinolytic agent was used. The possible pathophysiology and management of the patient is discussed.

  19. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  20. 3D dosimetry study of 188Re liquid balloon for intravascular brachytherapy using BANG polymer gel dosemeters

    International Nuclear Information System (INIS)

    Wuu, S.; Schiff, P.B.; Maryanski, M.; Liu, T.; Borzillary, S.; Weinberger, J.

    2002-01-01

    It has been suggested that the combination of intravascular brachytherapy and coronary stent implantation may result in further reduction of restenosis after percutaneous balloon angioplasty. The use of an angioplasty balloon filled with a P 188 Re liquid beta source for intravascular brachytherapy provides the advantage of accurate source positioning and uniform dose distribution to the coronary vessel wall. The effect of source edge and stent on the dose distribution of the target tissue may be clinically important. In BANG gels, the absorbed radiation produces free-radical chain polymerisation of acrylic monomers that are initially dissolved in the gel. The number of polymer particles is proportional to the absorbed dose. In this study, 3D dose distributions are presented for 188 Re balloons, with and without stents, using a prototype He-Ne laser CT scanner and the proprietary BANG polymer gel dosemeters. (author)

  1. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  2. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  3. LumenRECON Guidewire: Pilot Study of a Novel, Nonimaging Technology for Accurate Vessel Sizing and Delivery of Therapy in Femoropopliteal Disease.

    Science.gov (United States)

    Nair, Pradeep K; Carr, Jeffrey G; Bigelow, Brian; Bhatt, Deepak L; Berwick, Zachary C; Adams, George

    2018-01-01

    Proper vessel sizing during endovascular interventions is crucial to avoid adverse procedural and clinical outcomes. LumenRECON (LR) is a novel, nonimaging, 0.035-inch wire-based technology that uses the physics-based principle of Ohm's law to provide a simple, real-time luminal size while also providing a platform for therapy delivery. This study evaluated the accuracy, reliability, and safety of the LR system in patients presenting for a femoropopliteal artery intervention. This multicenter, prospective pilot study of 24 patients presenting for peripheral intervention compared LR measurements of femoropopliteal artery size to angiographic visual estimation, duplex ultrasound, quantitative angiography, and intravascular ultrasound. The primary effectiveness and safety end point was comparison against core laboratory adjudicated intravascular ultrasound values and major adverse events, respectively. Additional preclinical studies were also performed in vitro and in vivo in swine to determine the accuracy of the LR guidewire system. No intra- or postprocedure device-related adverse events occurred. A balloon or stent was successfully delivered in 12 patients (50%) over the LR wire. Differences in repeatability between successive LR measurements was 2.5±0.40% ( R 2 =0.96) with no significant bias. Differences in measurements of LR to other modalities were 0.5±1.7%, 5.0±1.8%, -1.5±2.0%, and 6.8±3.4% for intravascular ultrasound core laboratory, quantitative angiography, angiographic, and duplex ultrasound, respectively. This study demonstrates that through a physics-based principle, LR provides a real-time, safe, reproducible, and accurate vessel size of the femoropopliteal artery during intervention and can additionally serve as a conduit for therapy delivery over its wire-based platform. © 2018 American Heart Association, Inc.

  4. Achievement report for fiscal 1999 on research and development of technologies for medical welfare equipment. Intravascular 3D ultrasound imaging system for supporting less invasive diagnosis; 1999 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu seika hokokusho. Shindan shiengata choonpa kekkannai sanjigen imaging system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    An ultrasonic probe with its point fine is navigated in blood vessels and body cavities by 3-dimensional ultrasonic signals (with the oscillator driven by transmission from a catheter for position detection) for the acquisition of accurate 3-dimensional ultrasound images in a less invasive way. The transmission and reception circuits are provided with circuits for ultrasound tomographic images and for navigation. Trial units are fabricated and tested for transmission waveform and reception performance. The scanner is rotated for the acquisition of intravascular 3-dimensional radial images. The scanner rotating rate is set at 30 rps for the scanner performance not to be affected by heartbeat and the rate is controlled by the observation unit which changes voltage for the control. The 3-dimensional display software program, thanks to the navigation function of the external probe, detects the external probe position relative to the small-diameter probe for the construction of accurate 3-dimensional images. Specifications for a total system, which makes full use of a navigation function, are compiled, consisting of a small-diameter probe and a body surface real-time 3-dimensional display. (NEDO)

  5. Clinical study of the hypothesis of “endogenous collateral wind” on ...

    African Journals Online (AJOL)

    This study was to propose the hypothesis of “endogenous collateral wind” based on the patho-mechanism of thrombogenesis complicated by ruptured plaque on ACS, and the theory of traditional Chinese medicine. Materials and Methods: Through successful coronary angiography (CAG), and intravascular ultrasound ...

  6. Heartbeat OCT: In vivo intravascular megahertz-optical coherence tomography

    NARCIS (Netherlands)

    T. Wang (Tianshi); A.F.H. Pfeiffer (Andreas); E.S. Regar (Eveline); W. Wieser (Wolfgang); H.M.M. van Beusekom (Heleen); C.T. Lancée (Charles); T. Springeling (Tirza); I. Krabbendam (Ilona); A.F.W. van der Steen (Ton); R. Huber (Roman); G. van Soest (Gijs)

    2015-01-01

    textabstractCardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging

  7. Quinine-induced disseminated intravascular coagulation.

    Science.gov (United States)

    Spearing, R L; Hickton, C M; Sizeland, P; Hannah, A; Bailey, R R

    Recurrent disseminated intravascular coagulation occurred in 3 women after ingestion of quinine tablets for cramp. All had circulating quinine-dependent antibodies to platelets and in 2 there was initial evidence of antibody consumption, with low titres that rose steeply over the next few days and remained high for many months.

  8. Intravascular brachytherapy: a model for the calculation of the dose

    International Nuclear Information System (INIS)

    Pirchio, Rosana; Martin, Gabriela; Rivera, Elena; Cricco, Graciela; Cocca, Claudia; Gutierrez, Alicia; Nunez, Mariel; Bergoc, Rosa; Guzman, Luis; Belardi, Diego

    2002-01-01

    In this study we present the radiation dose distribution for a theoretical model with Montecarlo simulation, and based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental in vivo model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a 32P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries (Au)

  9. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  10. The effects of serial intravascular transfusions in ascitic/hydropic RhD-alloimmunized fetuses.

    Science.gov (United States)

    Craparo, F J; Bonati, F; Gementi, P; Nicolini, U

    2005-02-01

    To evaluate the effects of serial intravascular transfusions on RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion by measuring multiple hematological/biochemical blood variables. Thirty-one singleton pregnancies were referred for management of RhD alloimmunization. Seven fetuses had hydrops on presentation and were transfused immediately. The remainder underwent weekly ultrasound examinations, and fetal blood sampling and transfusion were performed on development of ascites. In the 104 samples collected overall from the 31 fetuses, glucose, uric acid, urea, creatinine, total protein, total and direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase, alkaline phosphatase, lactic dehydrogenase, amylase, pseudocholinesterase (PCHE), creatine kinase, triglycerides and cholesterol were measured and compared with a reference range for non-anemic fetuses. The median gestational age at first transfusion was 26 (range, 18-34) weeks. There were three fetal losses after the first transfusion, two of which were due to procedure-related complications; one further loss occurred. At the first transfusion fetal hematocrit, pO2, total protein, PCHE, creatinine and urea concentrations were significantly decreased compared to reference data, while total and direct bilirubin, AST, ALT, amylase, triglyceride and uric acid concentrations were increased. In all surviving fetuses ascites/hydrops had disappeared by the second transfusion. Fetal pO2, total protein, AST, ALT and PCHE concentrations had normalized by the third transfusion. Correction of fetal anemia did not affect the other variables. RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion had a survival rate of 87%. Alterations of several biochemical fetal blood indices are present at the first sampling/transfusion, but most variables normalize with intravascular transfusions. Copyright 2005 ISUOG.

  11. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

    DEFF Research Database (Denmark)

    Falk, Erling

    2012-01-01

    The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving...

  12. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies : A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

    NARCIS (Netherlands)

    G.J. Tearney (Guillermo); E.S. Regar (Eveline); T. Akasaka (Takashi); S. Adriaenssens (Stef); P. Barlis (Peter); H.G. Bezerra (Hiram); B.E. Bouma (Brett); N. Bruining (Nico); J.-M. Cho (Jin-Man); S. Chowdhary (Saqib); M.A. Costa (Marco); R. de Silva (Ranil); J. Dijkstra (Jouke); C. di Mario (Carlo); D. Dudeck (Darius); E. Falk (Erling); M.D. Feldman (Marc); P.J. Fitzgerald (Peter); H.M. Garcia-Garcia (Hector); N. Gonzalo (Nieves); J.F. Granada (Juan); G. Guagliumi (Giulio); N.R. Holm (Niels); Y. Honda (Yasuhiro); F. Ikeno (Fumiaki); Y. Kawasaki; W. Kochman (Waclav); L. Koltowski (Lukasz); T. Kubo (Takashi); T. Kume (Teruyoshi); H. Kyono (Hiroyuki); C.C.S. Lam (Cheung Chi Simon); G. Lamouche (Guy); D.P. Lee (David); M.B. Leon (Martin); A. Maehara (Akiko); O. Manfrini (Olivia); G.S. Mintz (Gary); K. Mizuno (Kyiouchi); M-A.M. Morel (Marie-Angèle); S. Nadkarni (Seemantini); H. Okura (Hiroyuki); H. Otake (Hiromasa); A. Pietrasik (Arkadiusz); F. Prati (Francesco); L. Rber (Lorenz); M. Radu (Maria); N. Rieber (Nikolaus); M. Riga (Maria); S.M. Rollins; M. Rosenberg (Mireille); V. Sirbu (Vasile); P.W.J.C. Serruys (Patrick); K. Shimada; T. Shinke (Toshiro); J. Shite (Junya); E. Siegel (Eliot); S. Sonada (Shinjo); U. Suter (Ueli); S. Takarada (Shigeho); A. Tanaka (Atsushi); M. Terashima (Mitsuyasu); T. Troels (Thim); M. Uemura (Mayu); G.J. Ughi (Giovanni); H.M.M. van Beusekom (Heleen); A.F.W. van der Steen (Ton); G.A. van Es (Gerrit Anne); G. van Soest (Gijs); R. Virmani (Renu); S. Waxman (Sergio); N.J. Weissman (Neil); G. Weisz (Giora)

    2012-01-01

    textabstractObjectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the

  13. Comparison of utility of blood cultures from intravascular catheters and peripheral veins: a systematic review and decision analysis.

    Science.gov (United States)

    Falagas, Matthew E; Kazantzi, Maria S; Bliziotis, Ioannis A

    2008-01-01

    Blood cultures are sometimes obtained from intravascular catheters for convenience. However, there is controversy regarding this practice. The authors compared the diagnostic test characteristics of blood cultures obtained from intravascular catheters and peripheral veins. Relevant studies for inclusion in this review were identified through PubMed (January 1970-October 2005) and the Cochrane Central Register of Controlled Trials. Studies that reported clear definitions of true bacteraemia were included in the analysis. Two reviewers independently extracted the data. Six studies were included in the analysis, providing data for 2677 pairs of blood cultures obtained from an intravascular catheter and a peripheral venipuncture. A culture obtained from an intravascular catheter was found to be a diagnostic test for bacteraemia with better sensitivity (OR 1.85, 95 % CI 1.14-2.99, fixed effects model) and better negative predictive value (almost with statistical significance) (OR 1.55, 95 % CI 0.999-2.39, fixed effects model) but with less specificity (OR 0.33, 95 % CI 0.18-0.59, random effects model) and lower positive predictive value (OR 0.41, 95 % CI 0.23-0.76, random effects model) compared to a culture taken by peripheral venipuncture. In a group of 1000 patients, eight additional patients with true bacteraemia would be identified and 59 falsely diagnosed as having bacteraemia by a blood culture obtained from an intravascular catheter compared to results of the peripheral blood culture. Given the consequences of undertreating patients with bacteraemia, the authors believe that, based on the available evidence, at least one blood culture should be obtained from the intravascular catheter.

  14. Techniques for Intravascular Foreign Body Retrieval

    International Nuclear Information System (INIS)

    Woodhouse, Joe B.; Uberoi, Raman

    2013-01-01

    As endovascular therapies increase in frequency, the incidence of lost or embolized foreign bodies is increasing. The presence of an intravascular foreign body (IFB) is well recognized to have the potential to cause serious complications. IFB can embolize and impact critical sites such as the heart, with subsequent significant morbidity or mortality. Intravascular foreign bodies most commonly result from embolized central line fragments, but they can originate from many sources, both iatrogenic and noniatrogenic. The percutaneous approach in removing an IFB is widely perceived as the best way to retrieve endovascular foreign bodies. This minimally invasive approach has a high success rate with a low associated morbidity, and it avoids the complications related to open surgical approaches. We examined the characteristics, causes, and incidence of endovascular embolizations and reviewed the various described techniques that have been used to facilitate subsequent explantation of such materials

  15. Intravascular ultrasound is a critical tool for accurate endograft sizing in the management of blunt thoracic aortic injury.

    Science.gov (United States)

    Wallace, Gabriel A; Starnes, Benjamin W; Hatsukami, Thomas S; Sobel, Michael; Singh, Niten; Tran, Nam T

    2015-03-01

    Accurate measurement of true aortic luminal diameter (ALD) is critical for endograft sizing in endovascular treatment of blunt thoracic aortic injury (BTAI), but ALD is dynamic and changes with respect to patients' hemodynamic status. This study aimed to characterize how ALD at the time of diagnosis of BTAI compares with ALD at the time of endovascular repair and later at follow-up. This is an Institutional Review Board-approved, single-institution retrospective analysis of prospectively obtained data. Patients were included who presented between July 2007 and December 2012 with computed tomography angiography (CTA)-diagnosed BTAI; who underwent thoracic endovascular aortic repair (TEVAR); and who underwent preoperative CTA, intraoperative intravascular ultrasound (IVUS), and postimplantation CTA. Comparison measurements of the ALD were made among CTA and IVUS images at the level of the left subclavian artery (LSCA) and between initial CTA and postimplantation CTA at 10, 15, and 20 cm distal to the LSCA. Theoretical endograft sizes were determined and compared for each ALD at the LSCA. Twenty-two patients were included in the analysis. Mean age was 38 ± 14 years (range, 17-61 years), with 82% men and mean Injury Severity Score of 43 ± 11 (range, 24-66). Mean time from emergency department admission to initial CTA was -1.2 ± 5 hours (range, -13 to 11.5 hours; negative time implies imaging at an outside facility before admission). Mean time from initial CTA to IVUS was 1.2 ± 1.4 days (range, 2.5 hours-5.7 days) and from IVUS to postimplantation CTA 33 ± 45 days (range, 17 hours-169 days). Overall, ALD measured by IVUS was significantly larger than that by initial CTA (Δ2.5 ± 3.1 mm; P < .05). ALD was also larger at 10, 15, and 20 cm distal to the LSCA in comparing the postimplantation CTA with the initial CTA (Δ2.4, 2.0, and 2.0 mm, respectively; all P < .05). More than half the devices would be sized differently with ALD measured by IVUS at the time of TEVAR

  16. Disseminated intravascular coagulation caused by moojenactivase, a procoagulant snake venom metalloprotease.

    Science.gov (United States)

    Sartim, Marco A; Cezarette, Gabriel N; Jacob-Ferreira, Anna L; Frantz, Fabiani G; Faccioli, Lucia H; Sampaio, Suely V

    2017-10-01

    Snake venom toxins that activate coagulation factors are key players in the process of venom-induced coagulopathy, and account for severe clinical manifestations. The present study applies a variety of biochemical, hematological, and histopathological approaches to broadly investigate the intravascular and systemic effects of moojenactivase (MooA), the first described PIIId subclass metalloprotease isolated from Bothrops sp. venom that activates coagulation factors. MooA induced consumption coagulopathy with high toxic potency, characterized by prolongation of prothrombin and activated partial thromboplastin time, consumption of fibrinogen and the plasma coagulation factors X and II, and thrombocytopenia. MooA promoted leukocytosis and expression of the proinflammatory cytokines interleukin-6 and tumor necrosis factor-α, accompanied by tissue factor-dependent procoagulant activity in peripheral blood mononuclear cells. This metalloprotease also caused intravascular hemolysis, elevated plasma levels of creatine kinase-MB, aspartate transaminase, and urea/creatinine, and induced morphopathological alterations in erythrocytes, heart, kidney, and lungs associated with thrombosis and hemorrhage. Diagnosis of MooA-induced disseminated intravascular coagulation represents an important approach to better understand the pathophysiology of Bothrops envenomation and develop novel therapeutic strategies targeting hemostatic disturbances. Copyright © 2017. Published by Elsevier B.V.

  17. Use of carbon dioxide as an intravascular contrast agent: A review of current literature

    OpenAIRE

    Ali, Fahad; Mangi, Muhammad Asif; Rehman, Hiba; Kaluski, Edo

    2017-01-01

    Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast ...

  18. Disseminated Intravascular Coagulation Following Induction of ...

    African Journals Online (AJOL)

    Background: Disseminated Intravascular coagulopathy (DIC) has been reported following use of Misoprostol which is an old drug with new indications in Obstetrics and. Gynecology. Its effectiveness, low cost, stability in tropical conditions and ease of administration as well as side effects like gastrointestinal effect, uterine ...

  19. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  20. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  1. Intravascular imaging with a storage phosphor detector

    Energy Technology Data Exchange (ETDEWEB)

    Shikhaliev, Polad M; Petrek, Peter; Matthews, Kenneth L II; Fritz, Shannon G [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA (United States); Bujenovic, L Steven [PET Imaging Center, Our Lady of the Lake Medical Center, Baton Rouge, LA (United States); Xu Tong, E-mail: pshikhal@lsu.ed [Department of Physics, Carleton University, Ottawa (Canada)

    2010-05-21

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm{sup 3} volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 {mu}Ci cm{sup -3} activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm{sup -2} were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360{sup 0} circumference. Spatial

  2. Ultrasound-guided peripheral and truncal blocks in pediatric patients

    Directory of Open Access Journals (Sweden)

    Mohamed Bilal Delvi

    2011-01-01

    Full Text Available Ultrasound has added a feather in the cap of the anesthesiologists as real-time nerve localization and drug deposition around the nerve structure under real-time guidance is now a reality, as the saying "seeing is believing" has been proven true with the advent of ultrasound in anesthesia. Pediatric patients are a unique group regarding their anatomical and physiological features in comparison with adults; regional blocks in adults with the anatomical landmark and surface marking are almost uniform across the adult population. The landmark technique in pediatric patients is not reliable in all patients due to the variability in the age and size; the advent of ultrasound in assisting nerve localization has changed the way regional blocks are achieved in children and the range of blocks performed on adults can now be performed on pediatric patients; with advances in the technology and dexterity of ultrasound equipment, the chances of success of blocks has increased with a smaller dose of the local anesthetic in comparison to the traditional methods. Anesthesiologists are now able to perform blocks with more accuracy and avoid complications like intravascular injection and injury to the pleura and peritoneum during routine practice with the assistance of high-frequency transducers and top of the range portable ultrasound machines; catheters can be inserted to provide a continuous analgesia in the postoperative period. This review article describes the common peripheral blocks in pediatric patients; the readers are encouraged to gain experience by attending workshops, hands-on practice under supervision, and conduct random controlled trials pertaining to ultrasound-guided blocks in the pediatric age group. The recent literature is encouraging and further research is promising; a wide range of blocks being described in detail by many prominent experts from all over the world.

  3. Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients

    NARCIS (Netherlands)

    Strasma, Paul J.; Finfer, Simon; Flower, Oliver; Hipszer, Brian; Kosiborod, Mikhail; Macken, Lewis; Sechterberger, Marjolein; van der Voort, Peter H. J.; DeVries, J. Hans; Joseph, Jeffrey I.

    2015-01-01

    Hyperglycemia and hypoglycemia are associated with adverse clinical outcomes in intensive care patients. In product development studies at 4 ICUs, the safety and performance of an intravascular continuous glucose monitoring (IV-CGM) system was evaluated in 70 postsurgical patients. The GluCath

  4. Asian-variant intravascular lymphoma in the African race

    Directory of Open Access Journals (Sweden)

    Holly Geyer

    2012-03-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBCL is an exceptionally rare form of non- Hodgkin lymphoma (NHL distinguished by the preferential growth of neoplastic cells within blood vessel lumen. Challenging to detect and deemed disseminated at diagnosis, this condition is characterized by a highly aggressive, inconspicuous course with a high mortality rate. We describe the case of a 48 year-old African-American female presenting with a two month history of low-grade fevers and malaise. Laboratory data was notable for anemia, thrombocytopenia, elevated liver function tests, and hematuria. An extensive workup for infectious, rheumatologic and malignant causes was negative. Her symptoms progressed and within two weeks, she was admitted for disseminated intravascular coagulation (DIC. Her course was complicated by diffuse pulmonary hemorrhage and ultimately, care was withdrawn. Autopsy identified widespread CD-20 positive intravascular large B-cell lymphoma with significant hepatosplenic involvement, characteristic of the Asian variant IVLBCL. This case uniquely highlights development of the Asian variant IVLBVL in a previously undescribed race. Identified by its intraluminal vascular growth pattern, IVLBCL generally spares lymphatic channels. Diagnosis and differentiation of this condition from other hematological malignancies via skin, visceral and bone marrow biopsy is imperative as anthracycline-containing chemotherapies may significantly improve clinical outcomes. This article outlines the common presentation, natural course, and treatment options of IVLBCL, along with the histopathology, immunohistochemistry, and chromosomal aberrations common to this condition.

  5. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    Science.gov (United States)

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p 3years to stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...

  7. Induction Therapy With Antithymocyte Globulin in Patients Undergoing Cardiac Transplantation Is Associated With Decreased Coronary Plaque Progression as Assessed by Intravascular Ultrasound.

    Science.gov (United States)

    Azarbal, Babak; Cheng, Richard; Vanichsarn, Christopher; Patel, Jignesh K; Czer, Lawrence S; Chang, David H; Kittleson, Michelle M; Kobashigawa, Jon A

    2016-01-01

    Antithymocyte globulin (ATG) is used as induction therapy after cardiac transplant for enhancing immunosuppression and delaying the initiation of nephrotoxic drugs. It is unknown if ATG induction is associated with decreased coronary plaque progression by intravascular ultrasound (IVUS). Patients transplanted between March 2010 and December 2012 with baseline and 1-year IVUS were included. All patients transplanted were included in a secondary analysis. Change in plaque progression was measured in a blinded fashion on matched coronary segments and contrasted between patients induced with ATG and those who were not. One hundred and three patients were included in IVUS arms. Mean age at transplant was 55.8 ± 12.6 years, and 33.0% were female. Patients induced with ATG were more sensitized (54.3% versus 14.3%). Plaque progression was attenuated in patients who received ATG by changes in maximal intimal area (1.0 ± 1.2 versus 2.3 ± 2.6 mm(2); P = 0.001), maximal percent stenosis (6.3 ± 7.9 versus 12.8 ± 12.3%; = 0.003), maximal intimal thickness (0.2 ± 0.2 versus 0.3 ± 0.3 mm; P = 0.035), and plaque volume (0.5 ± 0.7 versus 1.0 ± 1.3 mm(3)/mm; P = 0.016). Rapid plaque progression by maximal percent stenosis (≥ 20%) occurred less frequently in the ATG arm (4.3% versus 26.3; P = 0.003). Survival (P = 0.242) and any treated rejection (P = 0.166) were not statistically different between groups. Patients receiving ATG had a higher rate of first-year infection (P = 0.003), perhaps related to increased intravenous antibiotic use immediately postoperatively, and a trend toward more biopsy-proven rejection (P = 0.073). Induction therapy with ATG is associated with reduced first-year coronary plaque progression as assessed by IVUS, despite an increased prevalence of sensitized patients with a trend toward more rejection. © 2016 American Heart Association, Inc.

  8. Local intravascular coagulation and fibrin deposition on intestinal ischemia-reperfusion in rats

    NARCIS (Netherlands)

    Schoots, Ivo G.; Levi, Marcel; Roossink, E. H. Paulina; Bijlsma, Pieter B.; van Gulik, Thomas M.

    2003-01-01

    Background. This study investigates intravascular coagulation and thrombotic obstruction in the splanchnic vasculature after intestinal ischemia in relation to epithelial integrity and function. Methods. Intestinal ischemia was induced in rats by superior mesenteric artery occlusion for 20 or 40

  9. Monooxignase ensymic system of a liver of rats exposed to intravascular laser irradiation of blood

    International Nuclear Information System (INIS)

    Ibadova, G.A.

    1997-01-01

    Experimental study of the dynamic monooxidation of liver enzymic system was carried out on rats with experimental salmonellosis and the influence of the blood intravascular laser irradiation of blood on these enzymes was revealed. It was determined that by experimental salmonellosis oppression of the MOES activity of hepatocytes occurred. The blood intravascular irradiation by He-Ne laser promotes MOES oppression in rats suffered from salmonellosis. IVLIB as well as UV-laser show pronounced effect on the enzymes detoxication protection, mobilize their resistance to endogenic intoxication under the conditions of experimental salmonellosis. (author)

  10. Theragnostic ultrasound using microbubbles in the treatment of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Yoon, Young Il; Bae, Yun Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-08-15

    The use of gas-filled microbubbles in perfusion monitoring as intravascular ultrasound contrast agents has recently become more common. Additionally, microbubbles are employed as carriers of pharmaceutical substances or genes. Microbubbles have great potential to improve the delivery of therapeutic materials into cells and to modify vascular permeability, causing increased extravasation of drugs and drug carriers. Prostate cancer is the most common neoplasm in Europe and America, with an incidence twice to three times that of lung and colorectal cancer. Its incidence is still rising in Asian countries, including Japan and Korea. In this review, we present current strategies regarding the synthesis of microbubbles with targeted ligands on their surfaces, with a focus on prostate cancer.

  11. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  12. Therapeutic intervention in disseminated intravascular coagulation: have we made any progress in the last millennium?

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2002-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. Recent knowledge on important pathogenetic mechanisms that may lead to DIC has resulted in novel preventive and

  13. Intravascular catheter sepsis | Mer | South African Medical Journal

    African Journals Online (AJOL)

    Intravascular devices are an integral component of modern-day medical practice. They are used to administer intravenous fluids, medications, blood products and parenteral nutrition. In addition, they serve as a valuable monitor of the haemodynamic status of critically ill patients.

  14. Three-dimensional contrast-enhanced MRI using an intravascular contrast agent for detection of traumatic intra-abdominal hemorrhage and abdominal parenchymal injuries: an experimental study

    International Nuclear Information System (INIS)

    Weishaupt, D.; Ruehm, S.G.; Patak, M.A.; Schmidt, M.; Debatin, J.F.; Hetzer, F.H.

    2000-01-01

    The aim of this study was to compare the performance of 3D MRI in conjunction with an intravascular contrast agent to spiral contrast-enhanced CT, regarding the detection of abdominal parenchymal injuries as well as peritoneal hemorrhage in an animal model. Liver and kidney injuries were created surgically in six female pigs under general anesthesia. All pigs underwent contrast-enhanced spiral CT and 3D MR imaging following administration of an intravascular contrast agent (NC100150 Injection). Two readers rated their confidence independently on MR and CT data sets using a five-point scale for the presence of organ injury and hemoperitoneum. Autopsy findings served as standard of reference. Sensitivity and specificity for MR in detecting hepatic and renal injuries as well as hemoperitoneum was 100 %. Computed tomography was less accurate with sensitivity and specificity values of 90 and 94 %, respectively. Receiver operating characteristics (ROC) analysis revealed a higher confidence when interpretation was based on MR images. In an animal model 3D MR imaging in conjunction with an intravascular contrast agent proved highly accurate in detecting and localizing parenchymal injuries to the upper abdomen as well as in detecting intraperitoneal blood collections. (orig.)

  15. Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization?

    Directory of Open Access Journals (Sweden)

    Alistair Kent

    2015-01-01

    Full Text Available Introduction: Inferior vena cava collapsibility index (IVC-CI has been shown to correlate with both clinical and invasive assessment of intravascular volume status, but has important limitations such as the requirement for advanced sonographic skills, the degree of difficulty in obtaining those skills, and often challenging visualization of the IVC in the postoperative patient. The current study aims to explore the potential for using femoral (FV or internal jugular (IJV vein collapsibility as alternative sonographic options in the absence of adequate IVC visualization. Methods: A prospective, observational study comparing IVC-CI and Fem- and/or IJV-CI was performed in two intensive care units (ICU between January 2012 and April 2014. Concurrent M-mode measurements of IVC-CI and FV- and/or IJV-CI were collected during each sonographic session. Measurements of IVC were obtained using standard technique. IJV-CI and FV-CI were measured using high-frequency, linear array ultrasound probe placed in the corresponding anatomic areas. Paired data were analyzed using coefficient of correlation/determination and Bland-Altman determination of measurement bias. Results: We performed paired ultrasound examination of IVC-IJV (n = 39 and IVC-FV (n = 22, in 40 patients (mean age 54.1; 40% women. Both FV-CI and IJV-CI scans took less time to complete than IVC-CI scans (both, P < 0.02. Correlations between IVC-CI/FV-CI (R 2 = 0.41 and IVC-CI/IJV-CI (R 2 = 0.38 were weak. There was a mean -3.5% measurement bias between IVC-CI and IJV-CI, with trend toward overestimation for IJV-CI with increasing collapsibility. In contrast, FV-CI underestimated collapsibility by approximately 3.8% across the measured collapsibility range. Conclusion: Despite small measurement biases, correlations between IVC-CI and FV-/IJV-CI are weak. These results indicate that IJ-CI and FV-CI should not be used as a primary intravascular volume assessment tool for clinical decision support in

  16. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  17. Intravascular pulmonary metastases from sarcoma: appearance on computed tomography in 3 cases

    International Nuclear Information System (INIS)

    Ting, P.T.; Burrowes, P.W.; Gray, R.R.

    2005-01-01

    Various common malignant neoplasms (ie, liver, kidney, stomach and breast) have been reported to embolize to the pulmonary arterial system. This uncommon occurrence can also result from metastatic sarcoma. We report 3 cases- 2 chondrosarcomas and 1 osteosarcoma-associated with intravascular motastases to the pulmonary vasculature and discuss the clinical presentation and differentiating radiologic features on computed tomography (CT). Intravascular pulmonary tumour emboli may present with nonspecific respiratory symptoms or remain completely asymptomatic, and therefore, many patients are often misdiagnosed with thromboembolic disease or undiagnosed until autopsy. Chest CTs in all our patients demonstrated a striking pattern of multifocal tubular branching beaded opacities along the pulmonary vasculature in a multilobular distribution. Our observations and a review of the literature indicate that chest CT is the most useful diagnostic tool for detecting intravascular pulmonary tumour emboli. CT can distinguish this entity from mucous plugging by demonstrating the normal adjacent bronchus. The tubular nature of these metastases distinguishes them from the more common parenchymal metastases. (author)

  18. Discriminant validity study of Achilles enthesis ultrasound.

    Science.gov (United States)

    Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio

    2016-01-01

    We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  19. Leiomyosarcoma of the Uterus with Intravascular Tumor Extension and Pulmonary Tumor Embolism

    International Nuclear Information System (INIS)

    McDonald, Douglas K.; Kalva, Sanjeeva P.; Fan, C.-M.; Vasilyev, Aleksandr

    2007-01-01

    We report the case of a 48-year-old woman presenting with recurrent uterine leiomyosarcoma (LMS) associated with right iliac vein and inferior vena cava (IVC) invasion and left lower lobe pulmonary tumor embolus. Because the prognosis and treatment differ from that of thrombotic pulmonary emboli, the differentiating imaging characteristics of intravascular tumor embolism are reviewed. To our knowledge, only two other cases of intravenous uterine leiomyosarcomatosis have been described in the existing literature, and this is the first reported case of the entity with associated intravascular tumor embolism

  20. Cardiovascular disease in haemodialysis: role of the intravascular innate immune system.

    Science.gov (United States)

    Ekdahl, Kristina N; Soveri, Inga; Hilborn, Jöns; Fellström, Bengt; Nilsson, Bo

    2017-05-01

    Haemodialysis is a life-saving renal replacement modality for end-stage renal disease, but this therapy also represents a major challenge to the intravascular innate immune system, which is comprised of the complement, contact and coagulation systems. Chronic inflammation is strongly associated with cardiovascular disease (CVD) in patients on haemodialysis. Biomaterial-induced contact activation of proteins within the plasma cascade systems occurs during haemodialysis and initially leads to local generation of inflammatory mediators on the biomaterial surface. The inflammation is spread by soluble activation products and mediators that are generated during haemodialysis and transported in the extracorporeal circuit back into the patient together with activated leukocytes and platelets. The combined effect is activation of the endothelium of the cardiovascular system, which loses its anti-thrombotic and anti-inflammatory properties, leading to atherogenesis and arteriosclerosis. This concept suggests that maximum suppression of the intravascular innate immune system is needed to minimize the risk of CVD in patients on haemodialysis. A potential approach to achieve this goal is to treat patients with broad-specificity systemic drugs that target more than one of the intravascular cascade systems. Alternatively, 'stealth' biomaterials that cause minimal cascade system activation could be used in haemodialysis circuits.

  1. Fluorescent Method for Observing Intravascular Bonghan Duct

    OpenAIRE

    Byung-Cheon Lee; Ku Youn Baik; Hyeon-Min Johng; Baekkyoung Sung; Kyung Soon Soh; Dae-In Kang; Kwang-Sup Soh

    2005-01-01

    Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of ...

  2. Evaluation of cerebral intravascular blood flow by time density curve study of intravenous digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, Toru; Kogure, Kyuya (Tohoku Univ., Sendai (Japan). School of Medicine); Sekine, Teiko; Satoh, Kei; Endoh, Minoru; Tsuburaya, Kenji; Hoshi, Akihiko

    1992-01-01

    Time density curve (TDC) can be reconstructed from the data of intravenous digital subtraction angiography (IVDSA). We evaluated peak time (PT) and modal transit time (MOTT) of the TDC as the probable indicator of cerebral intravascular blood flow. Cerebral IVDSA and single photon emission CT (SPECT) were performed on 12 patients with ischemic cerebrovascular disease, which consisted of 3 internal carotid artery (ICA) occlusions, one middle cerebral artery (MCA) occlusion, one anterior cerebral artery (ACA) branch occlusion and 7 lacunar infarctions. We classified former 4 patients as occlusion group and latter 8 as reference group. In 3 patients (2 ICA and one MCA occlusions), SPECT study revealed definite hypoaccumulation in the MCA territory of occlusive side. Two regions of interest (ROI) were placed on the territories of right and left middle cerebral arteries in the frontal view of cerebral IVDSA. Digital data processor fitted {gamma} curve to the TDC of each ROI, and calculated PT and MOTT. The absolute lateralities of PT and MOTT of MCA territory was significantly (p<0.05) larger in occlusion group than reference group. Patients with hypoaccumulation in SPECT had significantly (p<0.02) larger laterality of MOTT than patients with isoaccumulation. One ICA occluded patient without hypoaccumulation in corresponding MCA territory had relatively small laterality of MOTT similar to the patients of ACA branch occlusion and lacunar infarction. These results suggest that PT and MOTT are possible to detect the laterality of the intravascular blood flow in MCA territories caused by major artery occlusion. Cerebral TDC study of IVDSA may be useful in some clinical therapeutic situations such as hemodilution or intra-arterial thrombolysis, and worth further clinical evaluation. (author).

  3. Intravascular stenting (IVaS) method for fingertip replantation.

    Science.gov (United States)

    Narushima, Mitsunaga; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Nakanishi, Kenji; Yamamoto, Yusuke; Araki, Jun; Abe, Hiroaki; Mundinger, Gerhard S; Kikuchi, Kazuki; Uehara, Eri

    2009-01-01

    Remarkable progress has been made in microsurgery. However, fingertip replantation following amputation has not gained much popularity because of its technical difficulty. We have developed the intravascular stenting (IVaS) method, in which a nylon monofilament is placed inside the vessel lumen to act as a temporary stent, facilitating anastomosis completion. This report describes 7 fingertip replantations using the IVaS method. Intravascular stent size varied from 4-0 to 6-0 (0.199-0.07 mm diameter). There were no cases in which the back wall of a vessel became inadvertently caught in the anastomosis. The overall survival rate for distal digital replants was 85% (6/7 replants). It is very difficult to evenly anastomose vessels of differing diameter, especially on a supermicrosurgical scale. In this respect, the IVaS method plays a role in stably anchoring the 2 vessel ends, allowing for the even spacing of suture knots, even in vessels of different caliber. Because of its ease of use and exactitude, many surgeons may be able to use the IVaS method to reliably complete small anastomoses in fingertip replantations.

  4. Polymer coating embolism from intravascular medical devices - a clinical literature review.

    Science.gov (United States)

    Chopra, Amitabh M; Mehta, Monik; Bismuth, Jean; Shapiro, Maksim; Fishbein, Michael C; Bridges, Alina G; Vinters, Harry V

    Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated devices have been increasingly adopted by interventional physicians and vascular surgeons to access and treat a wider range of clinical presentations. Recent clinical literature highlights the presence of polymer coating emboli within the anatomy - a result of coating separation from an intravascular device - and associates it with a range of adverse clinical sequelae. The 2015 U.S. Food and Drug Administration safety communication titled "Lubricious Coating Separation from Intravascular Medical Devices" acknowledges these concerns and concludes that it will work with stakeholders to develop nonclinical test methodologies, establish performance criteria, and identify gaps in current national and international device standards for coating integrity performance. Despite this communication and multiple case reports from interventional physicians, pathologists, dermatologists and other involved physician specialties, polymer coating embolism remains clinically underrecognized. This article consolidates the available literature on polymer coating embolism (1986-2016) and highlights the following relevant information for the physician: (a) the history and elusive nature of polymer coating embolism; (b) potential incidence rates of this phenomenon; (c) reported histologic findings and clinical effects of polymer emboli in the anatomy; (d) the importance of the collaborative clinician-pathologist partnership to report polymer embolism findings; and (e) the importance to study particulate release from intravascular devices so as to further understand and potentially evolve coated interventional technologies. Preliminary research on coatings highlights the potential of using iterations of coatings on medical devices that attain the desired therapeutic result and mitigate or eliminate particulates altogether. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  6. Pulmonary intravascular lymphoma detected by FDG PET-CT: a case report.

    Science.gov (United States)

    Kohan, A A; Paganini, L; Biedak, P; Arma, J I; Dalurzo, M C L; Garcia-Monaco, R D

    2013-01-01

    Intravascular lymphoma is a rare subtype of extranodal Non-Hodgkin's lymphoma. Its prognosis is poor in a high percentage of cases due to its insidious appearance and low clinical suspicion. Its diagnosis is usually only reached after an autopsy. It may affect different organs as a whole or only one organ. It is extremely rare that the lung is the only damaged organ. Its diagnosis depends of the clinician's suspicion and proper evaluation with imaging studies as well as correct selection of the organ to be biopsied. When detected on time, the treatment of choice is a combination of a series of chemotherapy associated to a monoclonal antibody (anti-CD20). We present the case of a male patient who underwent a positron emission tomography-computed tomography with 2-[F-18]-fluoro-2 deoxy-D-glucose (FDG) due to symptoms suggestive of a lymphoproliferative disease with no clear structural abnormalities. The images led to a diagnosis of pulmonary intravascular large B cell lymphoma. Copyright © 2012 Elsevier España, S.L. and SEMNIM. All rights reserved.

  7. Management of subarachnoid hemorrhage classified grade V. Possibility of intravascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Uzura, Masahiko; Oshima, Kousuke; Morishima, Hiroyuki; Uchida, Kazuyoshi; Watanabe, Hiroyuki; Nakamura, Homare; Tanaka, Katsuyuki; Sekino, Hiroaki; Akashi, Katsuya [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    2001-10-01

    Management outcomes in poor-grade patients (World Federation of Neurological Surgeons Committee on a Universal Subarachnoid Hemorrhage Grading Scale Grade V) with ruptured cerebral aneurysms have historically been unsatisfactory. In the present study, we examined the possibility of intravascular treatment for ruptured aneurysm detected by 3-Dimensional CT angiography (3D-CTA) in poor-grade SAH patients. From April 1997 to July 2000, 3D-CTA was performed on 54 of 73 patients admitted with Grade V subarachnoid hemorrhage (SAH). Excluding 3 patients who underwent emergency surgery for ruptured aneurysms and intracerebral hematomas, CT findings from the remaining 51 patients were analyzed. The study included 23 men and 28 women, ranging in age from 28 to 91 with an average age of 63.6. The patients' initial scores on the Glasgow Coma Scale upon admission were 3 in 36 patients (including 19 patients who had undergone cardio-pulmonary arrest), 4 in 11 patients, 5 in 2 patients, and 6 in 2 patients. Ruptured aneurysms responsible for SAH were clearly delineated in 41 aneurysms from 39 patients, with 32 aneurysms in the anterior circulation and 9 in the posterior circulation. Patients with Glasgow Coma Scale of 4 or higher whose score did not progressively decrease for 12 hours after symptom onset were considered for intravascular treatment. In our study, 4 of 39 patients (10.3%) met these criteria. Glasgow Outcome Scale results were good recovery in 1 case, moderate disability in 1 case, severe disability in 1 case, and death in the remaining 48 cases. These results suggest that the management course for poor-grade (WFNS Grade V) SAH patients who retain brain stem reflexes contain the following: identification of aneurysms by 3D-CTA, maintenance of adequate sedation and external drainage to treat acute hydrocephalus, continued minimum 12-hour observation, monitoring levels of consciousness where possible, and consideration of aggressive therapy including

  8. [INVITED] Surface plasmon cavities on optical fiber end-facets for biomolecule and ultrasound detection

    Science.gov (United States)

    Yang, Tian; He, Xiaolong; Zhou, Xin; Lei, Zeyu; Wang, Yalin; Yang, Jie; Cai, De; Chen, Sung-Liang; Wang, Xueding

    2018-05-01

    Integrating surface plasmon resonance (SPR) devices upon single-mode fiber (SMF) end facets renders label-free sensing systems that have a simple dip-and-read configuration, a small form factor, high compatibility with fiber-optic techniques, and invasive testing capability. Such devices are not only low cost replacement of current equipments in centralized laboratories, but also highly desirable for opening paths to new applications of label-free optical sensing technologies, such as point-of-care immunological tests and intravascular ultrasound imaging. In this paper, we explain the requirements and challenges for such devices from the perspectives of biomolecule and ultrasound detection applications. In such a context, we review our recent work on SMF end-facet SPR cavities. This include a glue-and-strip fabrication method to transfer a nano-patterned thin gold film to the SMF end-facet with high yield, high quality and high alignment precision, the designs of distributed Bragg reflector (DBR) and distributed feedback (DFB) SPR cavities that couple efficiently with the SMF guided mode and reach quality factors of over 100, and the preliminary results for biomolecule interaction sensing and ultrasound detection. The particular advantages and potential values of these devices have been discussed, in terms of sensitivity, data reliability, reproducibility, bandwidth, etc.

  9. Intravascular radiation for restenosis prevention: could it be the holy grail?

    International Nuclear Information System (INIS)

    King, S.B.

    1996-01-01

    This brief editorial discusses the use of intravascular radiation in preventing restenosis after angioplasty in coronary interventions. Results in porcine coronary arteries and clinical applications are briefly reported. (UK)

  10. Imminent Cardiac Risk Assessment via Optical Intravascular Biochemical Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, D.; Wetzel, L; Wetzel, M; Lodder, R

    2009-01-01

    Heart disease is by far the biggest killer in the United States, and type II diabetes, which affects 8% of the U.S. population, is on the rise. In many cases, the acute coronary syndrome and/or sudden cardiac death occurs without warning. Atherosclerosis has known behavioral, genetic and dietary risk factors. However, our laboratory studies with animal models and human post-mortem tissue using FT-IR microspectroscopy reveal the chemical microstructure within arteries and in the arterial walls themselves. These include spectra obtained from the aortas of ApoE-/- knockout mice on sucrose and normal diets showing lipid deposition in the former case. Also pre-aneurysm chemical images of knockout mouse aorta walls, and spectra of plaque excised from a living human patient are shown for comparison. In keeping with the theme of the SPEC 2008 conference Spectroscopic Diagnosis of Disease this paper describes the background and potential value of a new catheter-based system to provide in vivo biochemical analysis of plaque in human coronary arteries. We report the following: (1) results of FT-IR microspectroscopy on animal models of vascular disease to illustrate the localized chemical distinctions between pathological and normal tissue, (2) current diagnostic techniques used for risk assessment of patients with potential unstable coronary syndromes, and (3) the advantages and limitations of each of these techniques illustrated with patent care histories, related in the first person, by the physician coauthors. Note that the physician comments clarify the contribution of each diagnostic technique to imminent cardiac risk assessment in a clinical setting, leading to the appreciation of what localized intravascular chemical analysis can contribute as an add-on diagnostic tool. The quality of medical imaging has improved dramatically since the turn of the century. Among clinical non-invasive diagnostic tools, laboratory tests of body fluids, EKG, and physical examination are

  11. Guidelines for the diagnosis and management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Toh, C. H.; Thachil, J.; Watson, H. G.

    2009-01-01

    The diagnosis of disseminated intravascular coagulation (DIC) should encompass both clinical and laboratory information. The International Society for Thrombosis and Haemostasis (ISTH) DIC scoring system provides objective measurement of DIC. Where DIC is present the scoring system correlates with

  12. Studies of nonlinear ultrasound propagation: safety considerations in the use of ultrasound for medical diagnosis - nonlinear propagation

    International Nuclear Information System (INIS)

    Egerton, B.; Barnett, S.; Vella, G.

    1994-01-01

    Diagnostic ultrasound is an established imaging modality without any documented harmful effects. New developments such as pulsed Doppler and intracavity investigations may result in increases in ultrasound exposures which could cause harm. Thermal mechanisms and cavitation may become relevant sources of bioeffects. The preliminary study described here investigates the distribution and amplitude of harmonics generated through nonlinear propagation of ultrasound in water. Knowledge of harmonic attenuation will help predict sites of enhanced heating and enable accurate modelling of clinical situations. This presentation is concerned with thermal safety guidelines, their relationship to a typical ultrasound beam profile for a single, medium focussed, transducer operating in water and possible sites of enhanced heating due to nonlinear propagation effects. Measurements were made of the amplitudes of the harmonics generated by the nonlinear propagation of ultrasound in water. The amplitudes of the harmonics were detected up to frequencies of 35 MHz and displayed using Fast Fourier Transform facilities within the oscilloscope. The nonlinearity parameter of the ultrasonic waveforms has been identified as an important factor in thermal effects of ultrasound interactions. The appearance of nonlinear distortion is shown to be dependant on the peak compressional pressure and distance from the ultrasound source. 20 refs., 2 figs

  13. The cerebral intravascular enhancement sign is not specific: a contrast-enhanced MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Bakshi, R.; Kinkel, W.R.; Bates, V.E.; Mechtler, L.L.; Kinkel, P.R. [Lucy Dent Imaging Center, University at Buffalo, NY (United States)

    1999-02-01

    The intravascular enhancement (IVE) sign, also known as the ``arterial enhancement sign``, is an abnormal finding in the brain on contrast-enhanced MRI studies. IVE has been described in arterial cerebrovascular disorders, most commonly in acute or subacute arterial ischemic infarcts. However, the specificity of this sign has not been established. We describe four patients with disorders other than arterial strokes in whom gadolinium-enhanced high-field (1.5 T) MRI suggested IVE. The conditions were herpes simplex viral encephalitis, idiopathic cerebellitis, pneumococcal meningitis, and superior sagittal sinus thrombosis with venous infarction. IVE in these cases may be due to multiple factors, including arterial, venous, perivascular, and leptomeningeal or sulcal contrast medium accumulation. Our observations suggest that arterial ischemia, previously described as the cardinal cause of IVE, probably does not explain all instances, and urge caution in interpreting this sign as a specific MRI manifestation of acute arterial infarction or ischemia. (orig.) With 4 figs., 1 tab., 44 refs.

  14. Intravascular versus surface cooling for targeted temperature management after out-of-hospital cardiac arrest

    DEFF Research Database (Denmark)

    Glover, Guy W; Thomas, Richard M; Vamvakas, George

    2016-01-01

    , maintenance and rewarming phases in addition to adverse events. All-cause mortality, as well as a composite of poor neurological function or death, as evaluated by the Cerebral Performance Category and modified Rankin scale were analysed. RESULTS: For patients managed at 33 °C there was no difference between......BACKGROUND: Targeted temperature management is recommended after out-of-hospital cardiac arrest and may be achieved using a variety of cooling devices. This study was conducted to explore the performance and outcomes for intravascular versus surface devices for targeted temperature management after...... out-of-hospital cardiac arrest. METHOD: A retrospective analysis of data from the Targeted Temperature Management trial. N = 934. A total of 240 patients (26%) managed with intravascular versus 694 (74%) with surface devices. Devices were assessed for speed and precision during the induction...

  15. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  16. Combined hyponatremia and hypocalcemia after intravascular absorption of 1.5% glycine during operative hysteroscopy. A case report

    Directory of Open Access Journals (Sweden)

    Sherif S. Sultan

    2016-07-01

    Full Text Available Intravascular absorption of distending media may complicate operative hysteroscopy. Consequences differ according to type, amount and speed of absorption of the distending media. We report a case of intravascular absorption of more than one liter of 1.5% glycine. A 36 years old female developed metabolic acidosis, hyponatremia and hypocalcemia during operative hysteroscopy scheduled for resection of a uterine fibroid. Serum sodium reached down to 119 mmol/l and ionized calcium to 0.898 mmol/l. Serial estimations of arterial blood gases and serum electrolytes were followed. Management was successful in preventing serious side effects. Meticulous monitoring of distending media input/output balance remains the cornerstone in prevention of intravascular absorption.

  17. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  18. Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal.

    Science.gov (United States)

    Pell, Gaby S; Lewis, David P; Branch, Craig A

    2003-02-01

    Accurate quantification of perfusion with the ADC techniques requires the suppression of the majority of the intravascular signal. This is normally achieved with the use of diffusion gradients. The TurboFLASH sequence with its ultrashort repetition times is not readily amenable to this scheme. This report demonstrates the implementation of a modified TurboFLASH sequence for FAIR imaging. Intravascular suppression is achieved with a modified preparation period that includes a driven equilibrium Fourier transform (DEFT) combination of 90 degrees-180 degrees-90 degrees hard RF pulses subsequent to the inversion delay. These pulses rotate the perfusion-prepared magnetization into the transverse plane where it can experience the suitably placed diffusion gradients before being returned to the longitudinal direction by the second 90 degrees pulse. A value of b = 20-30 s/mm(2) was thereby found to suppress the majority of the intravascular signal. For single-slice perfusion imaging, quantification is only slightly modified. The technique can be readily extended to multislice acquisition if the evolving flow signal after the DEFT preparation is considered. An advantage of the modified preparation scheme is evident in the multislice FAIR images by the preservation of the sign of the magnetization difference. Copyright 2003 Wiley-Liss, Inc.

  19. Ultrasound for critical care physicians: hypotension after a MVA

    Directory of Open Access Journals (Sweden)

    Schmitz E

    2014-03-01

    Full Text Available No abstract available. Article truncated after first page. A 25 year old woman was a restrained driver in a rollover motor vehicle accident (MVA and suffered a C5-C6 fracture-dislocation with spinal cord injury. She was lucid and able to follow commands and could move her upper extremities but not her lower extremities. She was given approximately 6 liters of fluid but required vasopressors to maintain her blood pressure. Initial ECG revealed a normal sinus rhythm without significant ST changes (Figure 1. Upon initial evaluation her blood pressure was low. Bedside ultrasound of the left anterior second intercostal space revealed a sliding lung sign and a 4 chamber view of her heart was performed (Figure 2. Which of the following is the most likely cause of her hypotension? 1. Blunt cardiac injury; 2. Intravascular volume depletion; 3. Neurogenic stunned myocardium; 4. Pericardial tamponade; 5. Pneumothorax ...

  20. Perioperative Intravascular Fluid Assessment and Monitoring: A Narrative Review of Established and Emerging Techniques

    Directory of Open Access Journals (Sweden)

    Sumit Singh

    2011-01-01

    Full Text Available Accurate assessments of intravascular fluid status are an essential part of perioperative care and necessary in the management of the hemodynamically unstable patient. Goal-directed fluid management can facilitate resuscitation of the hypovolemic patient, reduce the risk of fluid overload, reduce the risk of the injudicious use of vasopressors and inotropes, and improve clinical outcomes. In this paper, we discuss the strengths and limitations of a spectrum of noninvasive and invasive techniques for assessing and monitoring intravascular volume status and fluid responsiveness in the perioperative and critically ill patient.

  1. Jaundice: a preliminary study with the ultrasound

    International Nuclear Information System (INIS)

    Chen Xiang; Sun Jian; Liu Haiping; Luo Weiquan

    2006-01-01

    Objective: To evaluate the ultrasound in imaging diagnosis of jaundice. Methods: The changes of ultrasonography of 116 patients with jaundice were correlatively studied with the final diagnosis. Results: Hepatocellular jaundice was found in 27 cases out of 116; and obstructive jaundice was revealed in other 89 cases. The level of obstruction was correctly assessed by ultrasound in 94.2% of the patients. The primary lesion was successfully identified by ultrasound in 87.6% cases of obstructive jaundice. Misdiagnosis was made in 8 cases. Conclusion: Ultrasonography can confirm the obstructive jaundice. The level of obstruction can be precisely located and the primary lesions can be correctly identified in most cases. Better understanding the sonographic characteristics of benign disorder such as inflam-matory mass of caput of pancreas and inflammatory stricture of common bile duct results in a higher diagnostic accuracy. (authors)

  2. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology.

    Science.gov (United States)

    Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S

    2016-05-01

    Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary

  3. Robust intravascular optical coherence elastography by line correlations

    International Nuclear Information System (INIS)

    Soest, Gijs van; Mastik, Frits; Jong, Nico de; Steen, Anton F W van der

    2007-01-01

    We present a new method for intravascular optical coherence elastography, which is robust against motion artefacts. It employs the correlation between adjacent lines, instead of subsequent frames. Pressure to deform the tissue is applied synchronously with the line scan rate of the optical coherence tomography (OCT) instrument. The viability of the method is demonstrated with a simulation study. We find that the root mean square (rms) error of the displacement estimate is 0.55 μm, and the rms error of the strain is 0.6%. It is shown that high-strain spots in the vessel wall, such as observed at the sites of vulnerable atherosclerotic lesions, can be detected with the technique

  4. Studies on the use of power ultrasound in leather dyeing.

    Science.gov (United States)

    Sivakumar, Venkatasubramanian; Rao, Paruchuri Gangadhar

    2003-03-01

    Uses of power ultrasound for acceleration/performing the chemical as well as physical processes are gaining importance. In conventional leather processing, the diffusion of chemicals through the pores of the skin/hide is achieved by the mechanical agitation caused by the paddle or drumming action. In this work, the use of power ultrasound in the dyeing of leather has been studied with the aim to improve the exhaustion of dye for a given processing time, to reduce the dyeing time and to improve the quality of dyed leather. The effect of power ultrasound in the dyeing of full chrome cow crust leather in a stationary condition is compared with dyeing in the absence of ultrasound as a control experiment both in a stationary as well as conventional drumming condition. An ultrasonic cleaner (150 W and 33 kHz) was used for the experiments. Actual power dissipated into the system was calculated from the calorimetric measurement. Experiments were carried out with variation in type of dye, amount of dye offer, temperature and time. The results show that there is a significant improvement in the percentage exhaustion of dye due to the presence of ultrasound, when compared to dyeing in absence of ultrasound. Experiments on equilibrium dye uptake carried out with or without ultrasound suggest that ultrasound help to improve the kinetics of leather dyeing. The results indicate that leathers dyed in presence of ultrasound have higher colour values, better dye penetration and fastness properties compared to control leathers. The physical testing results show that strength properties of the dyed leathers are not affected due to the application of ultrasound under the given process conditions. Apparent diffusion coefficient during the initial stage of dyeing process, both in presence and in absence of ultrasound was calculated. The values show that ultrasound helps in improving the apparent diffusion coefficient more for the difficult dyeing conditions such as in the case of metal

  5. The study of cardiovascular changes by intravascular injection of contrast media

    International Nuclear Information System (INIS)

    Kim, Yang Sook; Park, Chang Yoon

    1986-01-01

    This investigation was aimed to study the effect of contrast media on the cardiovascular system. So in this study, pithed rats were used whether alteration in cardiovascular system by contrast media were controlled centrally. Furthermore, several hypertonic solutions were also used to clarify the effect of contrast media. The results are as follows: 1. Intravenous injection of contrast media in rats (2.5 ml/kg) caused hypotension and bradycardia. The effects were neither blocked by pretreatment of atropine nor pyribenzamine+atropine. 2. NaCI 4.7%, dextrose 24.8%, urea 9.0% and glycerol 10.1% (v/v) which were equiosmolar with contrast media, caused hypotension, but did not affect the heart rate. 3. In pithed rats, intravenous injection of Angiografin increased blood pressure in a dose-dependant manner, and caused decrease in heart rate compared with those of control rats. 4. In pithed rats, bradycardia by intravascular injection with Angiografin was partially blocked by atropine. 5. Metrizamide of which iodine content was adjusted to 280 mg/ml caused increased in blood pressure when was injected intravenously in pithed rats with little effect on heart rate. 6. When perfused with contrast media in rat hindlimb at 15 ml/min./kg speed both perfusion pressure and flow effluent increased, simultaneously. These results suggest that hypotension might be caused by the central effect due to hyperosmolarity of contrast media and bradycardia caused by both parasympathetic stimulation and direct inhibitory action on the cardiac conductive system.

  6. Effects of Hypoxia on Erythrocyte Membrane Properties—Implications for Intravascular Hemolysis and Purinergic Control of Blood Flow

    Directory of Open Access Journals (Sweden)

    Ryszard Grygorczyk

    2017-12-01

    Full Text Available Intravascular hemolysis occurs in hereditary, acquired, and iatrogenic hemolytic conditions but it could be also a normal physiological process contributing to intercellular signaling. New evidence suggests that intravascular hemolysis and the associated release of adenosine triphosphate (ATP may be an important mechanism for in vivo local purinergic signaling and blood flow regulation during exercise and hypoxia. However, the mechanisms that modulate hypoxia-induced RBC membrane fragility remain unclear. Here, we provide an overview of the role of RBC ATP release in the regulation of vascular tone and prevailing assumptions on the putative release mechanisms. We show importance of intravascular hemolysis as a source of ATP for local purinergic regulation of blood flow and discuss processes that regulate membrane propensity to rupture under stress and hypoxia.

  7. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  8. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  9. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  10. Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation

    NARCIS (Netherlands)

    Bakhtiari, Kamran; Meijers, Joost C. M.; de Jonge, Evert; Levi, Marcel

    2004-01-01

    Objectives: A diagnosis of disseminated intravascular coagulation (DIC) is hampered by the lack of an accurate diagnostic test. Based on the retrospective analysis of studies in patients with DIC, a scoring system (0-8 points) using simple and readily available routine laboratory tests has been

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  12. Thyroid storm complicated by bicytopenia and disseminated intravascular coagulation.

    Science.gov (United States)

    Tokushima, Yoshinori; Sakanishi, Yuta; Nagae, Kou; Tokushima, Midori; Tago, Masaki; Tomonaga, Motosuke; Yoshioka, Tsuneaki; Hyakutake, Masaki; Sugioka, Takashi; Yamashita, Shu-ichi

    2014-07-24

    Male, 23. Thyroid storm. Delirium • diarrhea • fever • hypertension • hyperventilation • tachycardia • weight loss. -. -. Endocrinology and Metabolic. Unusual clinical course. The clinical presentation of thyroid storm includes fever, tachycardia, hypertension, and neurological abnormalities. It is a serious condition with a high mortality rate. Furthermore, some other complications affect the clinical course of thyroid storm. Although it is reported that prognosis is poor when thyroid storm is complicated by disseminated intravascular coagulation syndrome (DIC) and leukopenia, reports of such cases are rare. A 23-year-old man presented with delirium, high pyrexia, diarrhea, and weight loss of 18 kg over 2 months. According to the criteria of Burch and Wartofsky, he was diagnosed with thyroid storm on the basis of his symptom-complex and laboratory data that confirmed the presence of hyperthyroidism. Investigations also found leukopenia, thrombocytopenia, and disseminated intravascular coagulation, all of which are very rare complications of thyroid storm. We successfully treated him with combined therapy including anti-thyroid medication, despite leukopenia. Early diagnosis and treatment are essential in ensuring a good outcome for patients with this rare combination of medical problems.

  13. Slow clearance gadolinium-based extracellular and intravascular contrast media for three-dimensional MR angiography.

    Science.gov (United States)

    Bremerich, J; Colet, J M; Giovenzana, G B; Aime, S; Scheffler, K; Laurent, S; Bongartz, G; Muller, R N

    2001-04-01

    The objective of this study was to assess two new slow-clearance contrast media with extracellular and intravascular distribution for magnetic resonance angiography (MRA). Extracellular Gd-DTPA-BC(2)glucA and intravascular Gd(DO3A)(3)-lys(16) were developed within the European Biomed2 MACE Program and compared with two reference compounds, intravascular CMD-A2-Gd-DOTA and extracellular GdDOTA, in 12 rats. Pre- and post-contrast three-dimensional MR (TR/TE = 5 msec/2.2 msec; isotropic voxel size 0.86 mm(3)) was acquired for 2 hours. Signal-to-noise enhancement (DeltaSNR) was calculated. Two minutes after injection, all contrast media provided strong vascular signal enhancement. The DeltaSNR for Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), CMD-A2-Gd-DOTA, and GdDOTA were 13.0 +/- 1.8, 25.0 +/- 3.2, 25.0 +/- 4.0, and 18.0 +/- 3.4, respectively. Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), and CMD-A2-Gd-DOTA cleared slowly from the circulation, whereas GdDOTA cleared rapidly. Vascular DeltaSNR at 2 hours were 2.9 +/- 0.6, 25.0 +/- 3.2, 25.0 +/- 4.0, and 0.4 +/- 1.0. Gd(DO3A)(3)-lys(16) provided strong vascular and minor background enhancement, and thus may be useful for MRA or perfusion imaging. Gd-DTPA-BC(2)glucA produces persistent enhancement of extracellular water, and thus may allow quantification of extracellular distribution volume and assessment of myocardial viability.

  14. Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Zerkowski Hans-Reinhard

    2006-05-01

    Full Text Available Abstract Background In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. Methods In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. Results A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. Conclusion Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.

  15. Hemostasia normal y coagulación intravascular diseminada en obstetricia Normal hemostasis and disseminated intravascular clotting in Obstetrics

    Directory of Open Access Journals (Sweden)

    Danilo Nápoles Méndez

    2012-03-01

    Full Text Available En el período gravido - puerperal, la coagulación sanguínea sufre cambios que se impone conocer para interpretar correctamente esos trastornos cuando se presentan en esta etapa, teniendo en cuenta las posibles complicaciones y el peligro para la vida que pueden presentarse. El objetivo del presente artículo es proporcionar a los obstetras una revisión bibliográfica que les permita actualizarse acerca del tema y facilite su modo de actuación ante pacientes con coagulación intravascular diseminada. Se concluye que es preciso diagnosticar tempranamente el proceso en la fase bioquímica de bajo grado y aplicar en las féminas el tratamiento expedito de la enfermedad de base para eliminar las complicaciones o disminuir su ocurrenciaIn the period from pregnancy to puerperium, blood clotting suffers changes which are important to be known in order to interpret correctly those dysfunctions when they appear in this stage, keeping in mind the possible complications and the danger for life which can take place. The objective of the present work is to provide the obstetricians a literature review that allows them to be updated about the topic and facilitate their performance in case of patients with disseminated intravascular clotting. It is concluded that it is necessary to have an early diagnosis on the process during the low grade biochemical phase and to apply in these women the expedite treatment of the base disease to eliminate complications or to decrease their occurrence.

  16. Ultrasound study of ovarian pain in pre adolescent and adolescent girls

    International Nuclear Information System (INIS)

    Sanguesa, C.; Muro, D.

    1999-01-01

    To assess the role of ultrasound in the study of acute ovarian pain in pre adolescent and adolescent girls. B-mode ultrasound was employed to study 40 ovarian lesions in 37 girls between the age of 6 and 17 years complaining of acute pelvic pain of ovarian origin. Thirteen of the lesions were also assessed by color Doppler ultrasound. We found 25 cases of hemorrhagic cysts, 8 of simple cyst and 7 of ovarian torsion. Surgical and pathological correlation was established in 17 cases (7 cases hemorrhagic cyst, 3 of simple cysts and 7 of ovarian torsion). The remaining lesions are being followed by clinical and ultrasonographic monitoring. Simple and hemorrhagic cysts presenting the so called hematocrit effect are easily diagnosed by B-mode ultrasound. The ultrasonographic features of torsion and certain hemorrhagic cysts are similar on occasion, and surgery and histologic assessment are necessary for the definitive diagnosis. Doppler ultrasound provides no additional information to aid in the diagnosis of these lesions. (Author) 28 refs

  17. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  18. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    International Nuclear Information System (INIS)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne; Dromain, Clarisse; Balleyguier, Corinne S.; Breucq, Catherine; Steyaert, Luc; Baldan, Enrica; Drevon, Harir

    2013-01-01

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  19. Diagnostic ultrasound imaging for lateral epicondylalgia: a case-control study.

    Science.gov (United States)

    Heales, Luke James; Broadhurst, Nathan; Mellor, Rebecca; Hodges, Paul William; Vicenzino, Bill

    2014-11-01

    Lateral epicondylalgia (LE) is clinically diagnosed as pain over the lateral elbow that is provoked by gripping. Usually, LE responds well to conservative intervention; however, those who fail such treatment require further evaluation, including musculoskeletal ultrasound. Previous studies of musculoskeletal ultrasound have methodological flaws, such as lack of assessor blinding and failure to control for participant age, sex, and arm dominance. The purpose of this study was to assess the diagnostic use of blinded ultrasound imaging in people with clinically diagnosed LE compared with that in a control group matched for age, sex, and arm dominance. Participants (30 with LE and 30 controls) underwent clinical examination as the criterion standard test. Unilateral LE was defined as pain over the lateral epicondyle, which was provoked by palpation, resisted wrist and finger extension, and gripping. Controls without symptoms were matched for age, sex, and arm dominance. Ultrasound investigations were performed by two sonographers using a standardized protocol. Grayscale images were assessed for signs of tendon pathology and rated on a four-point ordinal scale. Power Doppler was used to assess neovascularity and rated on a five-point ordinal scale. The combination of grayscale and power Doppler imaging revealed an overall sensitivity of 90% and specificity of 47%. The positive and negative likelihood ratios for combined grayscale and power Doppler imaging were 1.69 and 0.21, respectively. Although ultrasound imaging helps confirm the absence of LE, when findings are negative for tendinopathic changes, the high prevalence of tendinopathic changes in pain-free controls challenges the specificity of the measure. The validity of ultrasound imaging to confirm tendon pathology in clinically diagnosed LE requires further study with strong methodology.

  20. Combined hyponatremia and hypocalcemia after intravascular absorption of 1.5% glycine during operative hysteroscopy. A case report

    OpenAIRE

    Sherif S. Sultan

    2016-01-01

    Intravascular absorption of distending media may complicate operative hysteroscopy. Consequences differ according to type, amount and speed of absorption of the distending media. We report a case of intravascular absorption of more than one liter of 1.5% glycine. A 36 years old female developed metabolic acidosis, hyponatremia and hypocalcemia during operative hysteroscopy scheduled for resection of a uterine fibroid. Serum sodium reached down to 119 mmol/l and ionized calcium to 0.898 mmol/l...

  1. Reduction of exit-site infections of tunnelled intravascular catheters among neutropenic patients by sustained-release chlorhexidine dressings: results from a prospective randomized controlled trial.

    Science.gov (United States)

    Chambers, S T; Sanders, J; Patton, W N; Ganly, P; Birch, M; Crump, J A; Spearing, R L

    2005-09-01

    Exit-site and tunnel infections of tunnelled central intravascular catheters are a frequent source of morbidity among neutropenic patients and may necessitate catheter removal. They require antimicrobial therapy that increases healthcare costs and is associated with adverse drug reactions. A prospective randomized clinical trial was conducted among adult patients undergoing chemotherapy in a haematology unit. Tunnelled intravascular catheters were randomized to receive the control of a standard dressing regimen as recommended by the British Committee for Standards in Haematology, or to receive the intervention of a sustained-release chlorhexidine dressing. Follow-up data were available in 112 of 114 tunnelled intravascular catheters which were randomized. Exit-site or combined exit-site/tunnel infections occurred in 23 (43%) of 54 catheters in the control group, and five (9%) of 58 catheters in the intervention group [odds ratio (OR) for intervention group compared with control group =0.13, 95% confidence intervals (CI) 0.04-0.37, P<0.001]. More tunnelled intravascular catheters were prematurely removed from the control group than the intervention group for documented infections [20/54 (37%) vs 6/58 (10%), OR=0.20, 95%CI 0.53-0.07]. However, there was no difference in the numbers of tunnelled intravascular catheters removed for all proven and suspected intravascular catheter-related infections [21/54 (39%) vs 19/58 (33%)], or in the time to removal of catheters for any reason other than death or end of treatment for underlying disease. Thus chlorhexidine dressings reduced the incidence of exit-site/tunnel infections of indwelling tunnelled intravascular catheters without prolonging catheter survival in neutropenic patients, and could be considered as part of the routine management of indwelling tunnelled intravascular catheters among neutropenic patients.

  2. Plasma volume, intravascular albumin and its transcapillary escape rate in patients with extensive skin disease

    DEFF Research Database (Denmark)

    Parving, H H; Worm, A M; Rossing, N

    1976-01-01

    Plasma volume and plasma concentration and transcapillary escape rate of albumin (TER alb), i.e. the fraction of intravascular mass of albumin that passes to the extravascular space per unit time, were determined using 125I-labelled human albumin in eight patients with extensive skin disease....... Plasma volume and plasma albumin concentration were reduced (P less than 0-05). Thus the intravascular albumin mass was moderately decreased to an average of 0-55 +/- 0-06 (s.d.) g/cm height compared with a normal mean value of 0-77 +/- 0-07 (s.d.) g/cm. This 29% decrease is statistically significant (P...... less than 0-001). The transcapillary escape rate of albumin (TER alb) was significantly elevated, mean 8-6 +/- 1-1 (s.d.) % X h-1, as compared to normal subjects, mean 5-6 +/- 1-1 (s.d.) % X h-1, (+54%, P less than 0-001). The same patients were studied again after a 1-week treatment with prednisone...

  3. Intravascular near-infrared fluorescence molecular imaging of atherosclerosis: toward coronary arterial visualization of biologically high-risk plaques

    Science.gov (United States)

    Calfon, Marcella A.; Vinegoni, Claudio; Ntziachristos, Vasilis; Jaffer, Farouc A.

    2010-01-01

    New imaging methods are urgently needed to identify high-risk atherosclerotic lesions prior to the onset of myocardial infarction, stroke, and ischemic limbs. Molecular imaging offers a new approach to visualize key biological features that characterize high-risk plaques associated with cardiovascular events. While substantial progress has been realized in clinical molecular imaging of plaques in larger arterial vessels (carotid, aorta, iliac), there remains a compelling, unmet need to develop molecular imaging strategies targeted to high-risk plaques in human coronary arteries. We present recent developments in intravascular near-IR fluorescence catheter-based strategies for in vivo detection of plaque inflammation in coronary-sized arteries. In particular, the biological, light transmission, imaging agent, and engineering principles that underlie a new intravascular near-IR fluorescence sensing method are discussed. Intravascular near-IR fluorescence catheters appear highly translatable to the cardiac catheterization laboratory, and thus may offer a new in vivo method to detect high-risk coronary plaques and to assess novel atherosclerosis biologics.

  4. Delayed coverage in malapposed and side-branch struts with respect to well-apposed struts in drug-eluting stents: In vivo assessment with optical coherence tomography

    NARCIS (Netherlands)

    J.L. Gutiérrez-Chico; E.S. Regar (Eveline); E. NüesC.H. (Eveline); T. Okamura (Takayuki); J.J. Wykrzykowska (Joanna); C. di Mario (Carlo); S.W. Windecker (Stephan); G.A. van Es (Gerrit Anne); P. Gobbens (Pierre); P. Jüni (Peter); P.W.J.C. Serruys (Patrick)

    2011-01-01

    textabstractBackground-Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition

  5. Feasibility study of local ultrasound hyperthermia in cancer therapy

    International Nuclear Information System (INIS)

    Jones, K.G.; Straube, W.; Emami, B.; Perez, C.A.

    1987-01-01

    This paper describes a retrospective analysis of patients treated at Washington University for recurrent or persistent cancer with Ultrasound Hyperthermia between October 1984 and June 1986. Fifteen of 102 lesions were treated during this time period with Ultrasound Hyperthermia instead of microwave hyperthermia due to the size of the lesion needing heat at depths greater than 4 cm. Also, the patients' lesion could not be implanted for interstitial microwave hyperthermia. Fourteen of the treated patients received concomitant radiotherapy, while one received concomitant Bleomycin. There were 79 total hyperthermia treatments delivered, of which 67 achieved a therapeutic temperature of 43 0 C for 60 minutes. During 15/79 treatments, patients experienced pain; of which 11/15 lead to poor heating. Only one treatment of the twelve poor treatments was secondary to technical difficulties. Complete local control was accomplished in seven patients, a partial response in four patients. The results of therapeutic heating and its relationship to the site of treatment and local control are presented, along with phantom studies of Ultrasound microwave hyperthermia reemphasizing the feasibility of using Ultrasound Hyperthermia

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  7. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    Science.gov (United States)

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Ultrasound-mediated microbubble enhancement of radiation therapy studied using three-dimensional high-frequency power Doppler ultrasound.

    Science.gov (United States)

    Kwok, Sheldon J J; El Kaffas, Ahmed; Lai, Priscilla; Al Mahrouki, Azza; Lee, Justin; Iradji, Sara; Tran, William Tyler; Giles, Anoja; Czarnota, Gregory J

    2013-11-01

    Tumor responses to high-dose (>8 Gy) radiation therapy are tightly connected to endothelial cell death. In the study described here, we investigated whether ultrasound-activated microbubbles can locally enhance tumor response to radiation treatments of 2 and 8 Gy by mechanically perturbing the endothelial lining of tumors. We evaluated vascular changes resulting from combined microbubble and radiation treatments using high-frequency 3-D power Doppler ultrasound in a breast cancer xenograft model. We compared treatment effects and monitored vasculature damage 3 hours, 24 hours and 7 days after treatment delivery. Mice treated with 2 Gy radiation and ultrasound-activated microbubbles exhibited a decrease in vascular index to 48 ± 10% at 24 hours, whereas vascular indices of mice treated with 2 Gy radiation alone or microbubbles alone were relatively unchanged at 95 ± 14% and 78 ± 14%, respectively. These results suggest that ultrasound-activated microbubbles enhance the effects of 2 Gy radiation through a synergistic mechanism, resulting in alterations of tumor blood flow. This novel therapy may potentiate lower radiation doses to preferentially target endothelial cells, thus reducing effects on neighboring normal tissue and increasing the efficacy of cancer treatments. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  9. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents.

    Science.gov (United States)

    Fuentes, Lara; Gómez-Lara, Josep; Salvatella, Neus; Gonzalo, Nieves; Hernández-Hernández, Felipe; Fernández-Nofrerias, Eduard; Sánchez-Recalde, Ángel; Alfonso, Fernando; Romaguera, Rafael; Ferreiro, José Luis; Roura, Gerard; Teruel, Luis; Gracida, Montserrat; Marcano, Ana Lucrecia; Gómez-Hospital, Joan-Antoni; Cequier, Ángel

    2018-05-01

    Stent thrombosis (ST) is a life-threatening complication after stent implantation. Intravascular ultrasound is able to discern most causes of ST. The aim of this study was to compare intravascular ultrasound findings between bare-metal stents (BMS) and drug-eluting stents (DES) in patients with late (31 days to 1 year) or very late ST (> 1 year). Of 250 consecutive patients with late or very late ST in 7 Spanish institutions, 114 patients (45.5% BMS and 54.5% DES) were imaged with intravascular ultrasound. Off-line intravascular ultrasound analysis was performed to assess malapposition, underexpansion, and neoatherosclerosis. The median time from stent implantation to ST was 4.0 years with BMS and 3.4 years with DES (P = .04). Isolated malapposition was similarly observed in both groups (36.5% vs 46.8%; P = .18) but was numerically lower with BMS (26.6% vs 48.0%; P = .07) in patients with very late ST. Isolated underexpansion was similarly observed in both groups (13.5% vs 11.3%; P = .47). Isolated neoatherosclerosis occurred only in patients with very late ST and was more prevalent with BMS (22.9%) than with DES (6.0%); P = .02. At 2.9 years' follow-up, there were 0% and 6.9% cardiac deaths, respectively (P = .06) and recurrent ST occurred in 4.0% and 5.2% of patients, respectively (P = .60). Malapposition was the most common finding in patients with late and very late ST and is more prevalent with DES in very late ST. In contrast, neoatherosclerosis was exclusively observed in patients with very late ST and mainly with BMS. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  11. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation . A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion . Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  12. Distribution of [35S] taurine in mouse retina after intravitreal and intravascular injection

    International Nuclear Information System (INIS)

    Pourcho, R.G.

    1977-01-01

    The distribution of [ 35 S] taurine in mouse retinae was studied by autoradiographic techniques after either intravitreal or intravascular injection. The route of injection did not affect the final localization. The major sites of label accumulation were the outer nuclear layer, the inner nuclear layer, and Mueller cell processes adjacent to the vitreal surface. The distribution was consistent with the interpretation that taurine was localized within two cellular compartments of mouse retina, photoreceptor cells and Mueller cells. (author)

  13. [Optimal intravascular brachytherapy: safety and radiation protection, reliability and precision guaranteed by guidelines, recommendations and regulatory requirements].

    Science.gov (United States)

    Quast, Ulrich; Kaulich, Theodor W; Lorenz, Joachim

    2002-02-01

    The success of intravascular brachytherapy relies entirely on the interdisciplinary approach. Interventional cardiologists, radiation oncologists and medical physicists must form a team from day 1. All members of the team need special knowledge and regular training in the field of vascular radiation therapy. Optimization of intravascular brachytherapy requires the use of standardized methods of dose specification, recording and reporting. This also implies using standardized methods of source calibration in terms of absorbed dose to water and having methods for simple internal control of the dosimetric quantities of new or replaced sources. Guidance is offered by international recommendations (AAPM TG 60, DGMP Report 16, NCS and EVA GEC-ESTRO). LEGAL REQUIREMENTS FOR RADIATION PROTECTION--WHAT'S NEW?: In Europe, new legal requirements on radiation protection issues have to be fulfilled. For Germany, the revised "Strahlenschutzverordnung" has been released recently. Nearly all organizational and medical processes are affected. For intravascular brachytherapy, several changes of requirements have to be considered. However, to follow these requirements does not cause serious problems. DGMP REPORT 16: GUIDELINES FOR MEDICAL PHYSICAL ASPECTS OF INTRAVASCULAR BRACHYTHERAPY: Evaluation of clinical results by comparison of intravascular brachytherapy treatment parameters is possible only if the prescribed dose and the applied dose distribution are reported clearly, completely and uniformly. The DGMP guidelines thus recommend to prescribe the dose to water at the system related reference point PRef at 2 mm radial distance for intracoronary application (and at 5 mm for peripheral vessels). The mean dose at 1 mm tissue depth (respectively at 2 mm) should be reported in addition. To safely define the planning target volume from the injured length, safety margins of at least 5 mm (10 mm) have to be taken into account on both ends. Safety margins have also to be considered for

  14. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  15. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume...... significantly; intravenous noradrenaline at 0.5 microgram/min had no effect on packed cell volume, whereas packed cell volume increased significantly at 3 micrograms of noradrenaline/min. No significant change in packed cell volume was found during saline infusion. 3. During adrenaline infusion at 6 micrograms...... in packed cell volume, plasma volume, intravascular mass of albumin and transcapillary escape rate of albumin during hypoglycaemia may be explained by the combined actions of adrenaline and insulin....

  16. A theoretical study of cylindrical ultrasound transducers for intracavitary hyperthermia

    International Nuclear Information System (INIS)

    Lin, W.-L.; Fan, W.-C.; Yen, J.-Y.; Chen, Y.-Y.; Shieh, M.-J.

    2000-01-01

    Purpose: The purpose of this paper was to examine the heating patterns and penetration depth when a cylindrical ultrasound transducer is employed for intracavitary hyperthermia treatments. Methods and Materials: The present study employs a simulation program based on a simplified power deposition model for infinitely long cylindrical ultrasound transducers. The ultrasound power in the tissue is assumed to be exponentially attenuated according to the penetration depth of the ultrasound beam, and a uniform attenuation for the entire treatment region is also assumed. The distribution of specific absorption rate (SAR) ratio (the ratio of SAR for a point within the tissue to that for a specific point on the cavity surface) is used to determine the heating pattern for a set of given parameters. The parameters considered are the ultrasound attenuation in the tissue, the cavity size, and the transducer eccentricity. Results: Simulation results show that the ultrasound attenuation in the tissue, the cavity size, and the transducer eccentricity are the most influential parameters for the distribution of SAR ratio. A low frequency transducer located in a large cavity can produce a much better penetration. The cavity size is the major parameter affecting the penetration depth for a small cavity size, such as interstitial hyperthermia. The heating pattern can also be dramatically changed by the transducer eccentricity and radiating sector. In addition, for a finite length of cylindrical transducer, lower SAR ratio appears in the regions near the applicator's edges. Conclusion: The distribution of SAR ratio indicates the relationship between the treatable region and the parameters if an appropriate threshold of SAR ratio is taken. The findings of the present study comprehend whether or not a tumor is treatable, as well as select the optimal driving frequency, the appropriate cavity size, and the eccentricity of a cylindrical transducer for a specific treatment

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  18. The lateral neostriatum is necessary for compensatory ingestive behaviour after intravascular dehydration in female rats.

    Science.gov (United States)

    Lelos, M J; Harrison, D J; Rosser, A E; Dunnett, S B

    2013-12-01

    Aberrant striatal function results in an array of physiological symptoms, including impaired consummatory and regulatory behaviours, which can lead to weight loss and dehydration. It was hypothesised, therefore, that cell loss in the neostriatum may contribute to altered fluid intake by regulating physiological signals related to dehydration status. To test this theory, rats with lesions of the lateral neostriatum and sham controls underwent a series of physiological challenges, including the experimental induction of intracellular and intravascular dehydration. No baseline differences in prandial or non-prandial drinking were observed, nor were differences in locomotor activity evident between groups. Furthermore, intracellular dehydration increased water intake in lesion rats in a manner comparable to sham rats. Interestingly, a specific impairment was evident in lesion rats after subcutaneous injection of poly-ethylene glycol was used to induce intravascular dehydration, such that lesion rats failed to adapt their water intake to this physiological change. The results suggest that the striatal lesions resulted in regulatory dysfunction by impairing motivational control over compensatory ingestive behaviour after intravascular hydration, while the physiological signals related to dehydration remain intact. Loss of these cells in neurodegenerative disorders, such Huntington's disease, may contribute to regulatory changes evident in the course of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Hydrophilic Polymer Embolism: Implications for Manufacturing, Regulation, and Postmarket Surveillance of Coated Intravascular Medical Devices.

    Science.gov (United States)

    Mehta, Rashi I; Mehta, Rupal I

    2018-03-19

    Hydrophilic polymers are ubiquitously applied as surface coatings on catheters and intravascular medical technologies. Recent clinical literature has heightened awareness on the complication of hydrophilic polymer embolism, the phenomenon wherein polymer coating layers separate from catheter and device surfaces, and may be affiliated with a range of unanticipated adverse reactions. Significant system barriers have limited and delayed reporting on this iatrogenic complication, the full effects of which remain underrecognized by healthcare providers and manufacturers of various branded devices. In 2015, the United States Food and Drug Administration acknowledged rising clinical concerns and stated that the agency would work with stakeholders to further evaluate gaps that exist in current national and international device standards for coated intravascular medical technologies. The present article reviews current knowledge on this complication as well as factors that played a role in delaying detection and dissemination of information and new knowledge once hazards and clinical risks were identified. Furthermore, organ-specific effects and adverse reaction patterns are summarized, along with implications for device manufacturing, safety assurance, and regulation. Qualitative and quantitative particulate testing are needed to optimize coated intravascular device technologies. Moreover, general enhanced processes for medical device surveillance are required for timely adverse event management and to ensure patient safety.

  20. Impact of Pre-Diabetes on Coronary Plaque Composition and Clinical Outcome in Patients With Acute Coronary Syndromes: An Analysis From the PROSPECT Study.

    Science.gov (United States)

    Farhan, Serdar; Redfors, Björn; Maehara, Akiko; McAndrew, Thomas; Ben-Yehuda, Ori; De Bruyne, Bernard; Mehran, Roxana; Giustino, Gennaro; Kirtane, Ajay J; Serruys, Patrick W; Mintz, Gary S; Stone, Gregg W

    2017-10-14

    The aim of this study was to investigate the impact of pre-diabetes (pre-DM) on coronary plaque characteristics and ischemic outcomes in patients with acute coronary syndromes (ACS). Pre-DM (i.e., the early stages of glucometabolic disturbance) is common among patients with ACS, but the extent to which pre-DM influences coronary plaque characteristics and the risk for adverse ischemic events is unclear. In the PROSPECT (Providing Regional Observations to Study Predictors of Events in Coronary Tree) study, patients with ACS underwent quantitative coronary angiography, grayscale intravascular ultrasound, and radiofrequency intravascular ultrasound after successful percutaneous coronary intervention. Patients were divided into 3 groups according to their glucometabolic status, as defined by the American Diabetes Association: normal glucose metabolism (NGM), pre-DM, and diabetes mellitus (DM). These groups were compared with regard to coronary plaque characteristics and the risk for major adverse cardiac events (MACEs) (defined as cardiac death or arrest, myocardial infarction, or rehospitalization for unstable or progressive angina). Among 547 patients, 162 (29.6%) had NGM, 202 (36.9%) had pre-DM, and 183 (33.4%) had DM. There were no significant differences between the groups with regard to intravascular ultrasound findings indicative of vulnerable plaques. Patients with DM had a higher crude rate of MACEs than those with pre-DM or NGM (25.9% vs. 16.3% and 16.1%; p = 0.03 and p = 0.02, respectively). In an adjusted Cox regression model using NGM as the reference group, DM (hazard ratio: 2.20; 95% confidence interval: 1.25 to 3.86; p = 0.006) but not pre-DM (hazard ratio: 1.29; 95% confidence interval: 0.71 to 2.33; p = 0.41) was associated with increased risk for MACEs. Impaired glucose metabolism is common among patients presenting with ACS. DM but not pre-DM is associated with an increased risk for MACEs. Thus, preventing patients from progressing from pre

  1. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    Science.gov (United States)

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  2. CT virtual intravascular endoscopy assessment of coronary artery plaques: A preliminary study

    International Nuclear Information System (INIS)

    Sun Zhonghua; Dimpudus, Franky Jacobus; Nugroho, Johanes; Adipranoto, Jeffrey Daniel

    2010-01-01

    Purpose: The purpose of this study was to investigate the potential value of CT virtual intravascular endoscopy (VIE) in the visualization and assessment of coronary plaques in patients suspected of coronary artery disease. Materials and methods: 20 (13 men, 7 women, mean age 54 years) consecutive patients with suspected coronary artery disease undergoing 64-slice CT angiography were included in the study. Four main coronary artery branches were assessed with regard to the presence of coronary plaques based on 2D axial, multiplanar reformation, 3D volume rendering and VIE visualizations. The coronary plaques were characterized into calcified, noncalcified and mixed plaques. The intraluminal appearances of these coronary plaques were demonstrated with VIE images and correlated with 2D and 3D images to determine the diagnostic value of VIE for the assessment of the plaques. Results: VIE was able to identify and demonstrate the intraluminal appearances of coronary plaques in 18 patients involving 32 coronary artery branches which were shown as an irregularly intraluminal protruding sign in extensively calcified plaques and smooth protruding appearance in noncalcified or focally calcified plaques. An irregular intraluminal appearance was also noticed in the presence of mixed plaques due to variable components with different CT attenuations contained within the plaques. VIE accurately confirmed the degree of coronary stenosis or occlusion despite the presence of heavy calcification. Conclusion: VIE could be used as a complementary tool to conventional CT visualizations for the analysis of luminal changes and assessment of disease extent caused by the coronary plaques.

  3. Disseminated intravascular coagulation as an unusual presentation of an Epstein-Barr virus infection

    NARCIS (Netherlands)

    van Steijn, JHM; van Tol, KM; van Essen, LH; Gans, ROB

    2000-01-01

    Epstein-Barr viral (EBV)-infection usually presents as fever, sore throat, fatigue, lymphadenopathy and atypical lymphocytosis. We describe a patient with disseminated intravascular coagulation as the presenting symptom caused by a primary EBV infection. (C) 2000 Elsevier Science B.V. All rights

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  5. Recovery of material parameters of soft hyperelastic tissue by an inverse spectral technique

    KAUST Repository

    Gou, Kun; Joshi, Sunnie; Walton, Jay R.

    2012-01-01

    An inverse spectral method is developed for recovering a spatially inhomogeneous shear modulus for soft tissue. The study is motivated by a novel use of the intravascular ultrasound technique to image arteries. The arterial wall is idealized as a

  6. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  7. Pulmonary ultrasound elastography: a feasibility study with phantoms and ex-vivo tissue

    Science.gov (United States)

    Nguyen, Man Minh; Xie, Hua; Paluch, Kamila; Stanton, Douglas; Ramachandran, Bharat

    2013-03-01

    Elastography has become widely used for minimally invasive diagnosis in many tumors as seen with breast, liver and prostate. Among different modalities, ultrasound-based elastography stands out due to its advantages including being safe, real-time, and relatively low-cost. While lung cancer is the leading cause of cancer mortality among both men and women, the use of ultrasound elastography for lung cancer diagnosis has hardly been investigated due to the limitations of ultrasound in air. In this work, we investigate the use of static-compression based endobronchial ultrasound elastography by a 3D trans-oesophageal echocardiography (TEE) transducer for lung cancer diagnosis. A water-filled balloon was designed to 1) improve the visualization of endobronchial ultrasound and 2) to induce compression via pumping motion inside the trachea and bronchiole. In a phantom study, we have successfully generated strain images indicating the stiffness difference between the gelatin background and agar inclusion. A similar strain ratio was confirmed with Philips ultrasound strain-based elastography product. For ex-vivo porcine lung study, different tissue ablation methods including chemical injection, Radio Frequency (RF) ablation, and direct heating were implemented to achieve tumor-mimicking tissue. Stiff ablated lung tissues were obtained and detected with our proposed method. These results suggest the feasibility of pulmonary elastography to differentiate stiff tumor tissue from normal tissue.

  8. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-01-01

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p -2 ± 0.01 μm and 1.99 x 10 -2 ± 0.004 μm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  9. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  10. The role of abdominal ultrasound in the diagnosis of typhoid fever: an observational study.

    Science.gov (United States)

    Younis, Saeed Nadhim

    2014-01-01

    To study the usefulness of abdominal ultrasound in the diagnosis of typhoid fever and to determine the common ultrasound findings early in the course of the disease. Abdominal ultrasound examination was performed within the first week of initiation of symptoms in 350 cases with clinical diagnosis of typhoid fever. Subsequent ultrasound follow-up examination was done 15 days later (beginning of the third week). All the patients proved to have positive Widal test and Sallmonella culture. The study was performed in Erbil-Iraq from the period January 1993 to October 2010. The following ultrasound findings were reported: hepatomegaly (31.4%), prominent intrahepatic bile ducts (64.85%), splenomegaly (100%), mesenteric lymphadenopathy (42.85%), bowel wall thickening (35.71%), acalculous cholecystitis (16.28%), perforations (1.14%), and ascites in (3.4%). The current study showed that the findings are typical enough to justify initiation of treatment for typhoid fever when serology is equivocal and culture is negative, and is fairly safe to say that normal ultrasound examination early in the course of febrile illness rules out typhoid fever. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. New treatment strategies for disseminated intravascular coagulation based on current understanding of the pathophysiology

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2004-01-01

    A variety of clinical conditions may cause systemic activation of coagulation, ranging from insignificant laboratory changes to severe disseminated intravascular coagulation (DIC). DIC consists of a widespread, systemic activation of coagulation, resulting in diffuse fibrin deposition in small and

  12. MULTISCAN--a Scandinavian multicenter second trimester obstetric ultrasound and serum screening study

    DEFF Research Database (Denmark)

    Jørgensen, F S; Valentin, L; Salvesen, K A

    1999-01-01

    AIM: To study the detection rates of second trimester ultrasound screening for neural tube defects (NTD), abdominal wall defects (AWD) and Down's syndrome (DS) in low risk populations at tertiary centers, and to compare the ultrasound screening detection rates with those that were obtainable by b...

  13. In Vitro Capture of Small Ferrous Particles with a Magnetic Filtration Device Designed for Intravascular Use with Intraarterial Chemotherapy: Proof-of-Concept Study.

    Science.gov (United States)

    Mabray, Marc C; Lillaney, Prasheel; Sze, Chia-Hung; Losey, Aaron D; Yang, Jeffrey; Kondapavulur, Sravani; Liu, Derek; Saeed, Maythem; Patel, Anand; Cooke, Daniel; Jun, Young-Wook; El-Sayed, Ivan; Wilson, Mark; Hetts, Steven W

    2016-03-01

    To establish that a magnetic device designed for intravascular use can bind small iron particles in physiologic flow models. Uncoated iron oxide particles 50-100 nm and 1-5 µm in size were tested in a water flow chamber over a period of 10 minutes without a magnet (ie, control) and with large and small prototype magnets. These same particles and 1-µm carboxylic acid-coated iron oxide beads were likewise tested in a serum flow chamber model without a magnet (ie, control) and with the small prototype magnet. Particles were successfully captured from solution. Particle concentrations in solution decreased in all experiments (P particles in water with a large magnet), 97% (50-100-nm particles in water with a small magnet), 99% (1-5-µm particles in water with a large magnet), 99% (1-5-µm particles in water with a small magnet), 95% (50-100-nm particles in serum with a small magnet), 92% (1-5-µm particles in serum with a small magnet), and 75% (1-µm coated beads in serum with a small magnet) lower compared with matched control runs. This study demonstrates the concept of magnetic capture of small iron oxide particles in physiologic flow models by using a small wire-mounted magnetic filter designed for intravascular use. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  14. SIADH and partial hypopituitarism in a patient with intravascular large B-cell lymphoma: a rare cause of a common presentation

    Science.gov (United States)

    Akhtar, Simeen; Cheesman, Edmund; Jude, Edward B

    2013-01-01

    Hyponatraemia is a very common electrolyte abnormality with varied presenting features depending on the underlying cause. The authors report the case of a 75-year-old, previously fit, gentleman who presented with weight loss, lethargy and blackouts. He required four admissions to the hospital over an 8-month period. Investigations revealed persistent hyponatraemia consistent with a diagnosis of syndrome of inappropriate antidiuretic hormone secretion, macrocytic anaemia and partial hypopituitarism. Unfortunately, all other investigations that were performed failed to identify the underlying cause and a diagnosis of intravascular large B-cell lymphoma was only confirmed following postmortem studies. The authors recommend that endocrinologists should be involved at the outset in the management of patients with persistent hyponatraemia and that intravascular large B-cell lymphoma should be considered in the differential diagnosis of hyponatraemia. PMID:23362070

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  16. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  17. Prevention of adverse reactions to intravascular contrast media

    International Nuclear Information System (INIS)

    Soyer, P.; Levesque, M.

    1990-01-01

    The exact mechanisms of adverse reactions to contrast media are still imperfectly known. However, these reactions may be classified as idiosyncratic. Non-idiosyncratic reactions can be prevented by using new, non-ionic contrast agents. Idiosyncratic reactions can be prevented by specific premedication. Patients with a history of idiosyncratic reaction may benefit from corticosteroids and antihistamines administered prophylactically. Patients who seem to be more likely than others to react to contrast media must be premedicated, the risk of reaction being identified and evaluated by questioning. It has recently been suggested that all patients about to receive an intravascular injection of contrast medium should also be premedicated [fr

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  19. Comparative ultrasound study of acute lateral ankle ligament ...

    African Journals Online (AJOL)

    The return to competitive level of sport dates were also documented and compared. A single blind randomised control study comparing the JSFB rehabilitation programme with conventional ankle rehabilitation programmes was used. Ultrasound examinations were done on all first time lateral ankle ligament injuries 72 ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  1. Interventional and intravascular MR angiography

    International Nuclear Information System (INIS)

    Ladd, M.E.; Debatin, J.F.

    2000-01-01

    Magnetic resonance imaging (MRI) has a number of characteristics which make it attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in any arbitrary oblique plane, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity and volume per unit time. For MR guidance of vascular interventions to be safe, catheters and guidewires must be visualized relative to the vascular system and surrounding tissues. A number of approaches for making instruments visible in an MR environment are presented, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts, whereas active techniques, including MR tracking, MR profiling, and active field inhomogeneity, use some form of electrical coil built into the instrument. The potential for obtaining high-resolution images of the vessel wall using coils built into a catheter is also discussed. These images provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications beyond those currently performed under X-ray fluoroscopic guidance. (orig.) [de

  2. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  4. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may produce minimal discomfort. If a Doppler ultrasound study is performed, you may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Most ultrasound examinations ...

  6. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  8. Anatomic factors affecting the use of ultrasound to predict vocal fold motion: A pilot study.

    Science.gov (United States)

    Masood, Maheer M; Huang, Benjamin; Goins, Allie; Hackman, Trevor G

    2018-04-13

    Ultrasonography is a well-established modality for visualization of head and neck anatomy. Using ultrasound to detect vocal fold mobility has been described before, but no study has evaluated factors affecting the exam reliability. The aim of the study is to determine anatomic factors influencing the reliability of ultrasound to detect vocal fold motion. Methods and materials Patients underwent ultrasound evaluation and flexible laryngoscopy to assess vocal fold motion from August 2015 to March 2016. Length, accuracy, and clarity of ultrasound examination were assessed, compared to flexible laryngoscopy. For patients with prior neck CT scan imaging, laryngeal anatomy was independently assessed by a blinded neuroradiologist. A total of 23 patients, 21 with bilateral vocal fold motion and two with unilateral paralysis, were enrolled. Vocal folds were visible in 19 patients (82%). Eight patients (42%) had good/excellent view and 11 patients (58%) had fair/difficult view. The ultrasound correctly detected absent movement of the vocal fold in the two patients with unilateral paralysis. A total of 19 patients had CT scans, and a linear correlation (r 2  = 0.65) was noted between the anterior thyroid cartilage angle measured on CT and the grade of view on ultrasound. Ultrasound was able to detect vocal fold motion in 82% of randomly screened patients. Ease of detection of vocal fold motion correlated with the anterior thyroid angle. Further studies are warranted to investigate the reproducibility of our results and how this might impact use of ultrasound for detection of vocal fold motion in the operative setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  10. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kevin S.H. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dowd, Christopher F.; Hess, Christopher P. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Mathes, Erin F.; Frieden, Ilona J. [University of California, San Francisco, Department of Dermatology, San Francisco, CA (United States); Rosbe, Kristina W. [University of California, San Francisco, Department of Otolaryngology, San Francisco, CA (United States); Hoffman, William Y. [University of California, San Francisco, Department of Surgery, San Francisco, CA (United States)

    2015-10-15

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  11. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    International Nuclear Information System (INIS)

    Koo, Kevin S.H.; Dowd, Christopher F.; Hess, Christopher P.; Mathes, Erin F.; Frieden, Ilona J.; Rosbe, Kristina W.; Hoffman, William Y.

    2015-01-01

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  12. Visualization of Chronic Myocardial Infarction Using the Intravascular Contrast Agent MS-325 (Gadofosveset in Patients

    Directory of Open Access Journals (Sweden)

    Thomas Thouet

    2012-01-01

    Full Text Available Aims. The aim of this study was to evaluate the potential of visualizing chronic myocardial infarction in patients using the intravascular CA MS-325 (gadofosveset, EPIX Pharmaceuticals, Mass, USA. Methods. Nine patients were enrolled in a clinical phase II multicenter trial for MRCA and perfusion imaging using MS-325. They had objective evidence of chronic myocardial infarction as visualized by previously performed late gadolinium (Gd enhancement imaging (LGE with a conventional extracellular Gd-DTPA CA (Magnevist, Bayer Healthcare, Germany, 0.2 mmol/kg/body weight serving as reference standard. A prepulse-optimized LGE study was performed immediately and at several time points after injection of MS-325 (0.05 mmol/kg/body weight. The number and localization of segments demonstrating LGE with MS-325 as well as signal intensities were compared with the reference standard (Gd-DTPA. Results. Using MS-325, LGE could be detected at every time point in all 9 patients. The accuracy of LGE with MS-325 as compared to LGE with Gd-DTPA was highest 54±4 minutes after contrast injection, resulting in a sensitivity of 84% with a specificity of 98%. Conclusion. The intravascular CA MS-325 has the potential to visualize chronic myocardial infarction. However, in comparison with Gd-DTPA, the transmural extent and the number of segments are smaller.

  13. Why Have So Many Intravascular Glucose Monitoring Devices Failed?

    Science.gov (United States)

    Smith, John L; Rice, Mark J

    2015-07-01

    Secondary to the inherent limitations of both point-of-care and central laboratory glucose technologies, continuous glucose measurement has recently enjoyed a high level of investment. Because of the perceived advantages by some of measuring in the intravascular space compared to the subcutaneous tissue, a number of technologies have been developed. In this review, we evaluate nine systems that have shown promise, although only one of these has been cleared for sale in the United States. The detection methodology, regulatory status, technical issues, and company circumstance surrounding each technology are examined. © 2015 Diabetes Technology Society.

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  15. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  16. Ultrasound cylindrical phased array for transoesophageal thermal therapy: initial studies

    International Nuclear Information System (INIS)

    Melodelima, David; Lafon, Cyril; Prat, Frederic; Birer, Alain; Cathignol, Dominique

    2002-01-01

    This work was undertaken to investigate the feasibility of constructing a cylindrical phased array composed of 64 elements spread around the periphery (OD 10.6 mm) for transoesophageal ultrasound thermotherapy. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were successively excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. For these feasibility studies, we used a cylindrical prototype (OD 10.6 mm) composed of 16 elementary transducers distributed over a quarter of the cylinder, all operating at 4.55 MHz. The active part was mechanically reinforced by a rigid damper structure behind the transducers. It was shown that an ultrasound field similar to that emitted by a plane transducer could be generated. Ex vivo experiments on pig's liver demonstrated that the ultrasound beam could be accurately rotated to generate sector-based lesions to a suitable depth (up to 19 mm). Throughout these experiments, exposures lasting 20 s were delivered at an acoustic intensity of 17 W cm -2 . By varying the power from exposure to exposure, the depth of the lesion at different angles could be controlled

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  19. Factors influencing nurses' decision-making process on leaving in the peripheral intravascular catheter after 96 hours: a longitudinal study.

    Science.gov (United States)

    Palese, Alvisa; Cassone, Andrea; Kulla, Annamaria; Dorigo, Sabrina; Magee, Jesse; Artico, Marco; Camero, Francesco; Cassin, Catia; Cialdella, Sandra; Floridia, Giuseppe; Nadlišek, Boris; Palcic, Annamaria; Valle, Giulia; Sclauzero, Paola

    2011-01-01

    The clinical and research debate on the peripheral intravascular (PIV) catheter length of stay in situ is ongoing. The principal aim of this study was to explore the factors behind a nurse's decision to leave a PIV in place for more than 96 hours. The study focused on 7 northern Italian hospitals in 2009. A consequent sample of 269 PIV catheters was included. Direct observation and interviews were adopted. The time of the expected PIV replacement was fixed at 96 hours after its positioning, in accordance with the international guideline. Several factors were taken into account in regard to replacement of the PIV catheters by nurses, ranging from analysis based on their own clinical experience with PIV complications and analysis of the patient's clinical situation to the critical analysis of their own work situation. This clinical decision-making process is valuable: leaving the PIV in place for more than 96 hours is a complex decision and not simply a guideline violation.

  20. A study on the incidence of thyroid cancer in gender ultrasound

    International Nuclear Information System (INIS)

    Kwak, Eun Suk; Lim, Cheong Hwan; Yang, Oh Nam

    2015-01-01

    Thyroid nodules are an endocrine disease often found in clinical practice, and patients with thyroid nodules found by chance have rapidly increased alongside development of thyroid ultrasound techniques for health examination purposes. This study analyzes the subjects’ general characteristics, thyroid ultrasounds, and fine needle aspiration cytology in order to find out the relationship between male and female thyroid nodules and thyroid cancer frequency. An ultrasound examination of the thyroid was performed for 32,973 individuals who visited the K Hospital of Health Examination. Subjects have no history of thyroid disease and are 20 years old or over. Data of general characteristics, diabetes) was collected by a written survey completed by the subject, and the ultrasound of the thyroid (thyroid nodules existence, size, number) and FNAC was used to find out the malignancy rate. Frequency of patients with thyroid nodule was 4,611 (26.1%) in men and 5,341 (34.9%) in women between 32,973 individuals. Women’s prevalence rate is significantly higher than men, and the prevalence rate significantly increased with age in men and women (p<0.05). The prevalence of multiple nodules was significantly higher in women (43.5%) than in men (35.6%), and significantly increased with age in men and women (p<0.05). The fine needle aspiration cytology was performed in 692 (men 342, women 350) subjects who showed signs of malignancy through ultrasound. Prevalence of malignancy of the nodules was higher in men (33.3%) than in women (29.4%) although it is not statistically significant. It is known that thyroid nodule prevalence in women is much higher than in men. But this study shows the men’s prevalence rate was not too low compared with women, and the men showed a rather higher malignancy rate in nodules than women. It is considered that the role of thyroid ultrasound is both important in men and women

  1. A study on the incidence of thyroid cancer in gender ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Eun Suk; Lim, Cheong Hwan [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Yang, Oh Nam [Dept. of Radiology, Mokpo Science University, Mokpo (Korea, Republic of)

    2015-06-15

    Thyroid nodules are an endocrine disease often found in clinical practice, and patients with thyroid nodules found by chance have rapidly increased alongside development of thyroid ultrasound techniques for health examination purposes. This study analyzes the subjects’ general characteristics, thyroid ultrasounds, and fine needle aspiration cytology in order to find out the relationship between male and female thyroid nodules and thyroid cancer frequency. An ultrasound examination of the thyroid was performed for 32,973 individuals who visited the K Hospital of Health Examination. Subjects have no history of thyroid disease and are 20 years old or over. Data of general characteristics, diabetes) was collected by a written survey completed by the subject, and the ultrasound of the thyroid (thyroid nodules existence, size, number) and FNAC was used to find out the malignancy rate. Frequency of patients with thyroid nodule was 4,611 (26.1%) in men and 5,341 (34.9%) in women between 32,973 individuals. Women’s prevalence rate is significantly higher than men, and the prevalence rate significantly increased with age in men and women (p<0.05). The prevalence of multiple nodules was significantly higher in women (43.5%) than in men (35.6%), and significantly increased with age in men and women (p<0.05). The fine needle aspiration cytology was performed in 692 (men 342, women 350) subjects who showed signs of malignancy through ultrasound. Prevalence of malignancy of the nodules was higher in men (33.3%) than in women (29.4%) although it is not statistically significant. It is known that thyroid nodule prevalence in women is much higher than in men. But this study shows the men’s prevalence rate was not too low compared with women, and the men showed a rather higher malignancy rate in nodules than women. It is considered that the role of thyroid ultrasound is both important in men and women.

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  3. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  4. Comparative study of ultrasound imaging, computed tomography and magnetic resonance imaging in gynecology

    International Nuclear Information System (INIS)

    Ishii, Kenji; Kobayashi, Hisaaki; Hoshihara, Takayuki; Kobayashi, Mitsunao; Suda, Yoshio; Takenaka, Eiichi; Sasa, Hidenori.

    1989-01-01

    We studied 18 patients who were operated at the National Defense Medical College Hospital and confirmed by pathological diagnosis. We compared ultrasound imaging, computed tomography (CT) and magnetic resonance imaging (MRI) of the patients. MRI was useful to diagnose enlargement of the uterine cavity and a small amount of ascites and to understand orientation of the pelvic organs. Ultrasound imaging is the most useful examination to diagnose gynecological diseases. But when it is difficult to diagnose by ultrasound imaging alone, we should employ either CT or MRI, or preferably both. (author)

  5. Automatic IVUS segmentation of atherosclerotic plaque with Stop & Go snake

    NARCIS (Netherlands)

    Brunenberg, E.J.L.; Pujol, O.; Haar Romenij, ter B.M.; Radeva, P.; Lelieveldt, B.P.F.; Haverkort, B.; de Laat, C.T.A.M.; Heijnsdijk, J.W.J.

    2006-01-01

    Since the upturn of intravascular ultrasound (IVUS)as an imaging technique for the coronary artery system, much research has been done to simplify the complicated analysis of the resulting images. In this study, an attempt to develop an automatic tissue characterization algorithm for IVUS images was

  6. Can ultrasound abdomen help in early diagnosis of diabetes mellitus? an observational study

    International Nuclear Information System (INIS)

    Anwar, J.; Aamir, M.O.; Imdad, Z.U.H.

    2015-01-01

    Diabetes mellitus is a common disease. Similarly, ultrasound findings of fatty change and renal crystals are commonly seen on ultrasound. In the personal observation of the main author over the past so many years it was noticed that Diabetes Mellitus, Fatty liver and renal crystals all sit well together. This study tries to establish a relationship between diabetes mellitus renal echogenic foci and fatty liver. This study is first of its kind, as nobody has ever before investigated an association between the renal echogenic foci and fatty liver in relation to diabetes mellitus. Methods: This cross-sectional, observational study was conducted at Radiology Department Combined Military Hospital, Kohat From 2nd June 2013 to 30th May 2014. Three hundred patients were collected on the basis of having fatty liver and renal echogenic foci on ultrasound and three hundred more patients were collected who had no fatty liver or renal echogenic foci on ultrasound. Their labs were done for diabetes mellitus. Results: The patients having renal echogenic foci together with fatty liver had 83% positive rate of being diabetics, while patients with no fatty liver and no echogenic foci on ultrasonography had only 0.6% Positive rate of being diabetics. Conclusion: Our results provided the first demonstration of an association between renal echogenic foci together with fatty liver with the diabetes mellitus. Thus ultrasound examination of abdomen can be helpful in its early diagnosis if we make a protocol of doing fasting and random blood sugars in all those patients who have positive renal echogenic foci and fatty liver on their ultrasound examination. (author)

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  8. Antenatal hydronephrosis: Negative predictive value of normal postnatal ultrasound - a 5-year study

    Energy Technology Data Exchange (ETDEWEB)

    Moorthy, I.; Joshi, N.; Cook, J.V. E-mail: jcook@epsom-sthelier.nhs.uk; Warren, M

    2003-12-01

    AIM: To determine whether normal postnatal ultrasound, as part of a strict screening protocol for the detection and follow-up of antenatal hydronephrosis, effectively excludes the majority of babies with congenital urinary tract abnormalities that would otherwise present with a urinary tract infection. MATERIALS AND METHODS: We retrospectively reviewed all babies who had postnatal follow-up of antenatally detected hydronephrosis over a 5-year period at our institution, a district general Trust with a specialist paediatric unit. We then studied all babies presenting with urinary tract infection before their first birthday to our institution over the same period. By cross-referencing these two study groups we were able to determine which babies developed a urinary tract infection having been previously discharged after normal postnatal ultrasound. RESULTS: Four hundred and twenty-five babies had postnatal follow-up of antenatal hydronephrosis. Of these, 284 were investigated with ultrasound alone. In the same 5-year period, 230 babies presented with urinary tract infection before their first birthday. Only three of these babies had been previously discharged after normal postnatal ultrasound. The negative predictive value of a normal postnatal ultrasound was therefore 98.9% (281/284) for babies who subsequently presented with a urinary tract infection before their first birthday. CONCLUSION: Careful antenatal and postnatal ultrasound with strict protocols is effective in detecting congenital renal tract abnormalities. Infants discharged after normal postnatal ultrasound are highly unlikely to still have an undetected urinary tract abnormality. We suggest that all babies with antenatal hydronephrosis are started on prophylactic antibiotics at birth, pending further investigation. All babies without features of severe obstruction antenatally should have their postnatal ultrasound delayed for a month. We recommend selective use of micturating cystourethrogram (MCUG

  9. Antenatal hydronephrosis: Negative predictive value of normal postnatal ultrasound - a 5-year study

    International Nuclear Information System (INIS)

    Moorthy, I.; Joshi, N.; Cook, J.V.; Warren, M.

    2003-01-01

    AIM: To determine whether normal postnatal ultrasound, as part of a strict screening protocol for the detection and follow-up of antenatal hydronephrosis, effectively excludes the majority of babies with congenital urinary tract abnormalities that would otherwise present with a urinary tract infection. MATERIALS AND METHODS: We retrospectively reviewed all babies who had postnatal follow-up of antenatally detected hydronephrosis over a 5-year period at our institution, a district general Trust with a specialist paediatric unit. We then studied all babies presenting with urinary tract infection before their first birthday to our institution over the same period. By cross-referencing these two study groups we were able to determine which babies developed a urinary tract infection having been previously discharged after normal postnatal ultrasound. RESULTS: Four hundred and twenty-five babies had postnatal follow-up of antenatal hydronephrosis. Of these, 284 were investigated with ultrasound alone. In the same 5-year period, 230 babies presented with urinary tract infection before their first birthday. Only three of these babies had been previously discharged after normal postnatal ultrasound. The negative predictive value of a normal postnatal ultrasound was therefore 98.9% (281/284) for babies who subsequently presented with a urinary tract infection before their first birthday. CONCLUSION: Careful antenatal and postnatal ultrasound with strict protocols is effective in detecting congenital renal tract abnormalities. Infants discharged after normal postnatal ultrasound are highly unlikely to still have an undetected urinary tract abnormality. We suggest that all babies with antenatal hydronephrosis are started on prophylactic antibiotics at birth, pending further investigation. All babies without features of severe obstruction antenatally should have their postnatal ultrasound delayed for a month. We recommend selective use of micturating cystourethrogram (MCUG

  10. MRI-controlled interstitial ultrasound brain therapy: An initial in-vivo study

    Science.gov (United States)

    N'Djin, W. Apoutou; Burtnyk, Mathieu; Lipsman, Nir; Bronskill, Michael; Schwartz, Michael; Kucharczyk, Walter; Chopra, Rajiv

    2012-11-01

    The recent emergence at the clinical level of minimally-invasive focal therapy such as laser-induced thermal therapy (LITT) has demonstrated promise in the management of brain metastasis [1], although control over the spatial pattern of heating is limited. Delivery of HIFU from minimally-invasive applicators enables high spatial control of the heat deposition in biological tissues, large treatment volumes and high treatment rate in well chosen conditions [2,3]. In this study, the feasibility of MRI-guided interstitial ultrasound therapy in brain was studies in-vivo in a porcine model. A prototype system originally developed for transurethral ultrasound therapy [4,5,6] was used in this study. Two burr holes of 12 mm in diameter were created in the animal's skull to allow the insertion of the therapeutic ultrasound applicator (probe) into the brain at two locations (right and left frontal lobe). A 4-element linear ultrasound transducer (f = 8 MHz) was mounted at the tip of a 25-cm linear probe (6 mm in diameter). The target boundary was traced to cover in 2D a surface compatible with the treatment of a 2 cm brain tumor. Acoustic power of each element and rotation rate of the device were adjusted in real-time based on MR-thermometry feedback control to optimize heat deposition at the target boundary [2,4,5]. Two MRT-controlled ultrasound brain treatments per animal have been performed using a maximal surface acoustic power of 10W.cm-2. In all cases, it was possible to increase accurately the temperature of the brain tissues in the targeted region over the 55°C threshold necessary for the creation of irreversible thermal lesion. Tissue changes were visible on T1w contrast-enhanced images immediately after treatment. These changes were also evident on T2w FSE images taken 2 hours after the 1st treatment and correlated well with the temperature image. On average, the targeted volume was 4.7 ± 2.3 cm3 and the 55°C treated volume was 6.7 ± 4.4 cm3. The volumetric

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  12. A 3D ultrasound study of sinus tract formation in hidradenitis suppurativa

    DEFF Research Database (Denmark)

    Wortsman, Ximena; Jemec, Gregor

    2013-01-01

    Imaging of hidradenitis suppurativa allows the study of both the lesion morphology and evolution. Hidradenitis lesions of different stages were studied using 3D ultrasound in a cross sectional pilot study. A total of 25 HS patients (18 female/ 7 male, aged 18-46 year-old) and 10 healthy controls (5...... female/5 male, aged 21-49 year-old) were studied. All patients were referred by dermatologists. All examinations were performed on the right axilla and compared with both controls and the skin outside the lesional areas. 3D ultrasound images demonstrated enlargement of the deepest portion of the hair...

  13. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  14. Enhancement or Reduction of Sonochemical Activity of Pulsed Ultrasound Compared to Continuous Ultrasound at 20 kHz?

    Directory of Open Access Journals (Sweden)

    Yujing Sun

    2013-04-01

    Full Text Available Little is known about the efficacy of pulsed ultrasound compared with continuous ultrasound. Previous studies on the efficacy of pulsed ultrasound were not systematic and gave different results. In this study, the effects of pulse length, pulse interval, pulse length × pulse intervals, and treatment time on sonochemical activity were investigated using a simple oxidation of iodide method and a comparison of the efficacy of pulsed ultrasound and continuous ultrasound is made. The results showed that the main factor in the efficacy of pulsed ultrasound was pulse length when pulse length varied from 0.1 to 1 s. However, the main factors were pulse length, the pulse length × pulse interval, and pulse interval when pulse length varied from 1 to 9 s. Pulsed ultrasound had no effect when the pulse length was 0.1 s; however, the sonochemical activity of pulsed ultrasound decreased compared to continuous ultrasound as the pulse length varied from 0.1 to 1 s. The sonochemical activity of pulsed ultrasound either increased or decreased compared to continuous ultrasound when pulse length varied from 1 to 9 s, but the increase or decrease had no clear trend. The sonochemical activity was constant at Ton/Toff = 2 s/2 s and slightly decreased at Ton/Toff = 3 s/2 s with time, whereas the sonochemical activity of continuous ultrasound significantly decreased with time. Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound depended on the pulse length and pulse interval.

  15. Recovery of material parameters of soft hyperelastic tissue by an inverse spectral technique

    KAUST Repository

    Gou, Kun

    2012-07-01

    An inverse spectral method is developed for recovering a spatially inhomogeneous shear modulus for soft tissue. The study is motivated by a novel use of the intravascular ultrasound technique to image arteries. The arterial wall is idealized as a nonlinear isotropic cylindrical hyperelastic body. A boundary value problem is formulated for the response of the arterial wall within a specific class of quasistatic deformations reflective of the response due to imposed blood pressure. Subsequently, a boundary value problem is developed via an asymptotic construction modeling intravascular ultrasound interrogation which generates small amplitude, high frequency time harmonic vibrations superimposed on the static finite deformation. This leads to a system of second order ordinary Sturm-Liouville boundary value problems that are then employed to reconstruct the shear modulus through a nonlinear inverse spectral technique. Numerical examples are demonstrated to show the viability of the method. © 2012 Elsevier Ltd. All rights reserved.

  16. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  17. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA

    International Nuclear Information System (INIS)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T.

    2002-01-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs

  18. Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography

    Science.gov (United States)

    Wang, Tianshi; Pfeiffer, Tom; Regar, Evelyn; Wieser, Wolfgang; van Beusekom, Heleen; Lancee, Charles T.; Springeling, Geert; Krabbendam, Ilona; van der Steen, Antonius F.W.; Huber, Robert; van Soest, Gijs

    2015-01-01

    Cardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging system that we called “Heartbeat OCT”, combining a fast Fourier Domain Mode Locked laser, fast pullback, and a micromotor actuated catheter, designed to examine a coronary vessel in less than one cardiac cycle. We acquired in vivo data sets of two coronary arteries in a porcine heart with both Heartbeat OCT, working at 2.88 MHz A-line rate, 4000 frames/s and 100 mm/s pullback speed, and with a commercial system. The in vivo results show that Heartbeat OCT provides faithfully rendered, motion-artifact free, fully sampled vessel wall architecture, unlike the conventional IV-OCT data. We present the Heartbeat OCT system in full technical detail and discuss the steps needed for clinical translation of the technology. PMID:26713214

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  1. One-stage surgery for removal of intravascular leiomyomatosis extending to right ventricle.

    Science.gov (United States)

    Chiang, Ching-Shu; Chen, Po-Lin; Kuo, Tzu-Ting; Chen, I-Ming; Wu, Nai-Yuan; Chang, Hsiao-Huang

    2018-03-01

    Intravascular leiomyomatosis (IVL) is a rare nonmalignant tumor that can be fatal if untreated. A 49-year-old nulliparous Asian woman who underwent hysterectomy and left salpingo-oophorectomy for multiple uterine leiomyomas 18 months prior presented complaining of intermittent palpitation and chest tightness for approximately 1 month. Echocardiography revealed a large mobile tumor mass extending from the inferior vena cava (IVC) to the right atrium that partially obstructed IVC flow and tricuspid inflow. Thoracicabdominopelvic computed tomography revealed a left adnexal tumor (4.8 × 2.5 cm) causing intravascular obstruction extending from the left internal iliac vein to the IVC, right atrium, and right ventricle. IVL with right heart involvement INTERVENTIONS:: Under cardiopulmonary bypass, a one-stage surgery combining sternotomy and laparotomy was performed. The tumor was approached and extracted via sternotomy, and tumor detachment and removal of residual tumors was accomplished via laparotomy. A firm, smooth, and regularly shape tumor 15.5 × 5.5 × 2.5 in size was completely removed and histopathologically confirmed as IVL. The patient tolerated the surgical procedure well and no postoperative complication was noted. We describe a one-stage surgical approach to completely remove an IVL extending to the right ventricle.

  2. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    Science.gov (United States)

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  4. Does use of a PACS increase the number of images per study? A case study in ultrasound.

    Science.gov (United States)

    Horii, Steven; Nisenbaum, Harvey; Farn, James; Coleman, Beverly; Rowling, Susan; Langer, Jill; Jacobs, Jill; Arger, Peter; Pinheiro, Lisa; Klein, Wendy; Reber, Michele; Iyoob, Christopher

    2002-03-01

    The purpose of this study was to determine if the use of a picture archiving and communications system (PACS) in ultrasonography increased the number of images acquired per examination. The hypothesis that such an increase does occur was based on anecdotal information; this study sought to test the hypothesis. A random sample of all ultrasound examination types was drawn from the period 1998 through 1999. The ultrasound PACS in use (ACCESS; Kodak Health Information Systems, Dallas, TX) records the number of grayscale and color images saved as part of each study. Each examination in the sample was checked in the ultrasound PACS database,.and the number of grayscale and color images was recorded. The comparison film-based sample was drawn from the period 1994 through 1995. The number of examinations of each type selected was based on the overall statistics of the section; that is, the sample was designed to represent the approximate frequency with which the various examination types are done. For film-based image counts, the jackets were retrieved, and the number of grayscale and color images were counted. The number of images obtained per examination (for most examinations) in ultrasound increased with PACS use. This was more evident with some examination types (eg, pelvis). This result, however, has to be examined for possible systematic biases because ultrasound practice has changed over the time since the authors stopped using film routinely. The use of PACS in ultrasonography was not associated with an increase in the number of images per examination based solely on the use of PACS, with the exception of neonatal head studies. Increases in the number of images per study was otherwise associated with examinations for which changes in protocols resulted in the increased image counts.

  5. Development of sup 1 sup 9 sup 2 Ir radiation sources for intravascular irradiation

    CERN Document Server

    Kogure, H; Iwamoto, S; Iwata, K; Kawauchi, Y; Nagata, Y; Sorita, T; Suzuki, K

    2003-01-01

    Intravascular brachytherapy is a novel therapy for preventing the restenosis of coronary artery by use of low-dose irradiation. JAERI and Kyoto University have been developing sup 1 sup 9 sup 2 Ir radiation sources by the cooperative research project entitled as 'The research on safety and effectiveness of the intravascular brachytherapy for preventing restenosis of the coronary artery disease' since 1998. The radiation source was introduced into the stenosis through a catheter (a guide-tube to insert directly into vascular) to irradiate the diseased part. Ten sup 1 sup 9 sup 2 Ir seed sources (phi 0.4 mm x 2.5 mm) were positioned between nylon spacers (phi 0.3 mm x 1.0 mm) in a flexible covering tube and the tube was plugged with a core-wire; the tube was shrunk to fix the inside materials and the size is 0.46 mm in diameter and 3 m in length. The physically optimal design was determined to insert the radiation source easily into vascular and to get the dose uniformity in the diseased part. The production me...

  6. Soleus muscle injury: sensitivity of ultrasound patterns

    Energy Technology Data Exchange (ETDEWEB)

    Balius, Ramon [Sport Catalan Council, Generalitat de Catalunya, Barcelona (Spain); Clinica CMI Diagonal, Barcelona (Spain); Rodas, Gil [F.C. Barcelona Medical Services, Barcelona (Spain); Pedret, Carles [Clinica CMI Diagonal, Barcelona (Spain); Clinica Mapfre de Medicina del Tenis, Sports Medicine and Imaging Department, Barcelona (Spain); Centre de Diagnostic per Imatge de Tarragona, Tarragona (Spain); Capdevila, Lluis [Universitat Autonoma de Barcelona, Laboratory of Sport Psychology, Barcelona (Spain); Alomar, Xavier [Clinica Creu Blanca, Barcelona (Spain); Bong, David A. [Instituto Poal de Reumatologia, Barcelona (Spain)

    2014-06-15

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  7. Soleus muscle injury: sensitivity of ultrasound patterns.

    Science.gov (United States)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluís; Alomar, Xavier; Bong, David A

    2014-06-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the "gold standard." In MRI studies, 24 cases (43.7%) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3%) and in the anterior aponeurosis (AMF) in 9 (16.4%). Thirty-one cases (56.3%) were musculotendinous injuries, with 9 cases (16.4%) in the medial aponeurosis (MMT), 11 cases (20%) in the lateral aponeurosis (LMT), and 11 cases (20%) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2% of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area.

  8. Soleus muscle injury: sensitivity of ultrasound patterns

    International Nuclear Information System (INIS)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluis; Alomar, Xavier; Bong, David A.

    2014-01-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  9. Ultrasound in differential diagnosis of periapical radiolucencies: A radiohistopathological study

    Science.gov (United States)

    Khambete, Neha; Kumar, Rahul

    2015-01-01

    Objectives: To evaluate the efficacy of ultrasound in differential diagnosis of periapical radiolucencies. Materials and Methods: Ten patients aged between 19 years and 40 years with periapical lesions associated with anterior maxillary or mandibular teeth were selected and consented for the study. Pre-operative periapical radiographs were obtained. Measurements and provisional diagnoses of the apical areas were made by two specialist observers on two separate occasions. Preoperative ultrasound examinations with Doppler flowmetry were then performed and the images assessed by two specialist observers for the size, contents, vascular supply and a provisional diagnosis made as to whether the lesion was a cyst or granuloma. Endodontic surgery was performed including curettage of the apical tissues to enable histopathological investigation, which provided the gold standard diagnosis. All measurements and findings were compared and statistically analyzed. Results: Total 10 lesions were identified in 10 patients. On periapical radiographs, lesions were readily identified but observers were unable to differentiate granuloma from cyst using either modality. Where sufficient buccal cortical bone had been resorbed, ultrasound imaging was simple but underestimated the size of the lesions compared with periapical radiographs. In all cases, the ultrasound diagnosis agreed with the histopathological gold standard. Conclusion: Ultrasonography (USG) can provide accurate information about the nature of intraosseous lesions of the jaws before any surgical procedure. It is proposed that USG with Doppler flowmetry can provide an additional diagnostic tool without invasive surgery, where treatment option is nonsurgical. PMID:25657525

  10. Simulation Study of Effects of the Blind Deconvolution on Ultrasound Image

    Science.gov (United States)

    He, Xingwu; You, Junchen

    2018-03-01

    Ultrasonic image restoration is an essential subject in Medical Ultrasound Imaging. However, without enough and precise system knowledge, some traditional image restoration methods based on the system prior knowledge often fail to improve the image quality. In this paper, we use the simulated ultrasound image to find the effectiveness of the blind deconvolution method for ultrasound image restoration. Experimental results demonstrate that the blind deconvolution method can be applied to the ultrasound image restoration and achieve the satisfactory restoration results without the precise prior knowledge, compared with the traditional image restoration method. And with the inaccurate small initial PSF, the results shows blind deconvolution could improve the overall image quality of ultrasound images, like much better SNR and image resolution, and also show the time consumption of these methods. it has no significant increasing on GPU platform.

  11. Mechanism study of multimode ultrasound pretreatment on the enzymolysis of wheat gluten.

    Science.gov (United States)

    Zhang, Yanyan; Li, Jing; Li, Suyun; Ma, Haile; Zhang, Hua

    2018-03-01

    Ultrasound pretreatment could improve the angiotensin-I converting enzyme (ACE) inhibitory activity of hydrolysates of wheat gluten (WG). The working mode of ultrasound has an important effect on the enzymatic hydrolysis of protein. The results showed that the optimum working mode of ultrasound was alternate dual-frequency mode (20/35 kHz), substrate concentration was 30 g L -1 , initial temperature of the suspension was 30 °C, ultrasound pretreatment time was 10 min and power density was 150 W L -1 . Under optimised conditions, ACE inhibitory activity of WG hydrolysates reached to its maximum value in advance. The surface hydrophobicity (H 0 ) of WG and the content of small peptides at the beginning of the enzymolysis were improved by the ultrasound pretreatment. The structure of WG was destroyed by the ultrasound pretreatment. The enzymatic residue of ultrasound pretreated WG were damaged greater than control. It was concluded that alternate dual-frequency ultrasound pretreatment improved the ACE inhibitory activity. Ultrasonic pretreatment may loosen the tissue of WG aggregate, and help the enzyme alcalase to attack the interior of WG aggregate easily, which resulted in the release of low molecular weight peptides from WG aggregate. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  16. Intrauterine intravascular transfusion for fetal haemolytic anaemia: the Western Australian experience.

    Science.gov (United States)

    Newnham, J P; Phillips, J M; Stock, R

    1992-11-16

    To report the first four years' clinical experience with fetal intravascular blood transfusion for the treatment of fetal haemolytic anaemia in Western Australia. King Edward Memorial Hospital, Perth, which is the sole tertiary level perinatal centre in Western Australia with a referral base of approximately 25,000 pregnancies each year. Transfusion was by injection of packed cells from Rh-negative donors into the fetal umbilical vein near the site of insertion into the placenta. Fetal haemoglobin levels were measured before and after each transfusion. In most cases, the fetus was paralysed by intramuscular tubocurarine. Sixty intravenous transfusions were performed in 20 pregnancies. At the time of the initial transfusion, the mean haemoglobin level was 5.8 g/dL (range, 2.5-8.5 g/dL) and six fetuses had signs of hydrops. The case survival rate was 80% and the procedure survival rate was 93%. Three of the deaths occurred in the first five cases. Caesarean section was performed during two of the procedures, one because of bleeding from the cord puncture site and one because of tamponade of the umbilical vessels. Fetal intravascular transfusion is a highly effective treatment for fetal alloimmunisation and allows pregnancies to continue to term and to be delivered vaginally. However, the procedure may be difficult and requires a team approach with ready access to fetal monitoring and emergency caesarean section. Our results suggest that increasing experience of the team is a major factor in improved outcome.

  17. High grade primary adrenal intravascular large B-cell lymphoma manifesting as Addison disease Linfoma intravascular de alto grado de células B grandes y origen suprarrenal que se manifiesta en forma de enfermedad de Addison

    Directory of Open Access Journals (Sweden)

    J. Venizelos

    2007-08-01

    Full Text Available We report a rare case of a 68 aged male who presented with adrenal failure and was diagnosed of high grade large B-cell lymphoma primarily arising in the adrenal glands. The patient was administrated with additional chemotherapy but he passed away 7 months later due to infection in the lungs. Intravascular lymphoma should be suspected in patients with bilateral adrenal masses who present with rapidly progressive adrenal insufficiency.Publicamos el caso poco frecuente de un varón de 68 años de edad que debutó con insuficiencia adrenal y fue diagnosticado de linfoma de alto grado de células B grandes ubicado principalmente en las glándulas suprarrenales. Al paciente le administraron quimioterapia adicional, pero falleció 7 meses después de infección pulmonar. El linfoma intravascular debe sospecharse en los pacientes con masas suprarrenales bilaterales que presenten insuficiencia adrenal rápidamente progresiva.

  18. Direct sGC activation bypasses no scavenging reactions of intravascular free oxy-hemoglobin and limits vasoconstriction

    NARCIS (Netherlands)

    N.J.H. Raat (Nicolaas); D.M. Tabima (D. Marcela); P. Specht (Patricia); J. Tejero (Jesús); M.P. Champion (Michael); D.B. Kim-Shapiro (Daniel); J.G. Baust (John ); E.G. Mik (Egbert); M. Hildesheim (Mariana); J.-P. Stasch (Johannes-Peter); E.-M. Becker (Eva-Maria); H. Truebel (Hubert); M.T. Gladwin (Mark)

    2013-01-01

    textabstractAims: Hemoglobin-based oxygen carriers (HBOC) provide a potential alternative to red blood cell (RBC) transfusion. Their clinical application has been limited by adverse effects, in large part thought to be mediated by the intravascular scavenging of the vasodilator nitric oxide (NO) by

  19. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  20. [Detection of small for gestational age fetuses during third trimester ultrasound. A monocentric observational study].

    Science.gov (United States)

    Peyronnet, V; Kayem, G; Mandelbrot, L; Sibiude, J

    2016-09-01

    Fetus small for gestational age (SGA) screening rate is evaluated around 21,7 % in France. Recommendations were developed to improve the efficiency of ultrasound conducted in the third trimester (T3), because neonatal consequences can be significant. This study aims to evaluate screening of SGA during T3 ultrasound and to describe causes for failure and differences with the recommendations of CNGOF. All children born between 2011 and 2012 with a birth weight below the 3rd percentile were included in this observational, retrospective, monocentric study. We noted that the diagnosis of SGA was placed on file. Then, as recommended by the CNGOF, we calculated estimated fetal weight (EFW) with Hadlock 3 and Hadlock 4, and the corresponding percentiles, using the biometrics from the ultrasound report. We thus could evaluate a new screening rate with SGA fetus identified through this technique. A total of 142 patients were included. By calculating correctly all EFW and checking abdominal circumference percentiles, the screening rate of SGA fetuses with T3 ultrasound increased from 40 % to 50 % and the overall screening rate (clinical and ultrasound) from 54 % to 66 %. By following the recommendations we found a real improvement in fetal SGA screening rates to T3 ultrasound with a potential benefit for their care. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Study of wet incineration of organic matters under ultrasounds

    International Nuclear Information System (INIS)

    Rey-Gaurez, F.

    2001-01-01

    The purpose of this study is to investigate the potentiality of power ultrasound for minimizing the volumes of solid waste and effluents generated by the spent nuclear fuel refining industry. In the first part, the advantages of power ultrasound for the decontamination of ion exchange resins (IER) is demonstrated: 1) sonication allows to remove 100 % of the 137 Cs and more than 20 % of the 60 Co initially present in the contaminated resins, 2) the decontamination is fast, 3) very simple experimental conditions are necessary (water, air or argon as saturating gas and weak electric intensity). The study of different chemical and sono-chemical parameters shows that decontamination seems to be related to the effects induced by cavitation: micro-streaming and solid erosion or disruption. In the second part, the selectivity of power ultrasound for the elimination of nitrogen (nitrate, nitro) aliphatic derivatives diluted in the PUREX process solvent is established. The nitrogen derivatives of butane or dodecane are removed under sonication while the solvent is scarcely damaged. The nitrogen derivatives of butane are quickly eliminated according to a thermal way in the cavitation bubble. A great number of kinetic data have been obtained and the influence of different parameters has been studied. The mechanisms are complex and initiated mainly by the homolytic cleavage of the O-N bond of butyl nitrate or nitrite and the C-N bond of nitrobutane. The elimination of nitrogen derivatives of dodecane is slower than the four-carbon component one. This preliminary kinetic study was difficult as the kinetic order was undetermined and a steady state concentration was reached after a short time of sonication. Unlike the four-carbon derivatives, the decomposition rate was not controlled by the boiling point of the long-chain derivatives. Nevertheless, good carbon balance (dodecane is the major product) has been obtained and led to potential mechanisms. (author) [fr

  2. Ultrasound-based scores as predictors for nodular hyperplasia in patients with secondary hyperparathyroidism: a prospective validation study.

    Science.gov (United States)

    Gwiasda, Jill; Kaltenborn, Alexander; Müller, Jörg A; Serttas, Michaela; Scheumann, Georg W F; Schrem, Harald; Jäger, Mark D

    2017-03-01

    Former studies evaluated echostructural and vascular patterns in ultrasound of the parathyroid gland to identify nodular hyperplasia in patients with secondary hyperparathyroidism due to chronic kidney disease. This prospective study aims to externally validate suggested ultrasound classifications. Parathyroid glands of 27 patients with secondary hyperparathyroidism undergoing parathyroidectomy were prospectively analyzed. Ultrasound including Doppler imaging was performed 1 day prior to surgery. Ultrasound data were available for 70 parathyroid glands. Echostructural and vascular scores according to previous studies were applied calculating the area under the receiver operating characteristic curve (AUROC). Overall correctness, sensitivity, and specificity of the investigated scores were assessed with the Youden index method. The Doppler score introduced by Vulpio and colleagues based on characteristic blood flow patterns in parathyroid glands showed an AUROC of 0.749 for the prediction of nodular hyperplasia with an overall correctness of 72.8%. Other ultrasound classifications based on blood flow patterns, as well as echostructure of the parathyroid gland displayed AUROCs of secondary hyperparathyroidism was externally validated for the first time. Other ultrasound scores fail as prognostic models in this study population. Doppler sonography of the parathyroid gland has prognostic capability to identify nodular hyperplasia as surrogate marker for patients with secondary hyperparathyroidism indicating the need for ablative or surgical treatment when failing conservative therapy.

  3. Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions.

    Science.gov (United States)

    Molins, Inés Gómez; Font, Juan Manuel Fernández; Alvaro, Juan Carrero; Navarro, Jose Luís Lledó; Gil, Marta Fernández; Rodríguez, Conrado M Fernández

    2010-12-28

    The extensive use of imaging techniques in differential diagnosis of abdominal conditions and screening of hepatocellular carcinoma in patients with chronic hepatic diseases, has led to an important increase in identification of focal liver lesions. The development of contrast-enhanced ultrasound (CEUS) opens a new window in the diagnosis and follow-up of these lesions. This technique offers obvious advantages over the computed tomography and magnetic resonance, without a decrease in its sensitivity and specificity. The new second generation contrast agents, due to their intravascular distribution, allow a continuous evaluation of the enhancement pattern, which is crucial in characterization of liver lesions. The dual blood supply in the liver shows three different phases, namely arterial, portal and late phases. The enhancement during portal and late phases can give important information about the lesion's behavior. Each liver lesion has a different enhancement pattern that makes possible an accurate approach to their diagnosis. The role of emerging techniques as a contrast-enhanced three-dimensional US is also discussed. In this article, the advantages, indications and technique employed during CEUS and the different enhancement patterns of most benign and malignant focal liver lesions are discussed.

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  8. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  9. Abdominal and pelvic ultrasound study of the maned wolf (Chrysocyon brachyurus

    Directory of Open Access Journals (Sweden)

    Luciana D. Guimarães

    2013-02-01

    Full Text Available The aim of the present study was the ultrasound characterization of the abdominal and pelvic regions of five maned wolves kept in captivity at the Triage Center of Wild Animals of the Federal University of Viçosa (Centro de Triagem de Animais Silvestres, Universidade Federal de Viçosa. This characterization included descriptions of ultrasonographic aspects and measurements of various structures using B-mode ultrasound. Biometric data were collected to assess the existence of significant linear correlations between these measurements and the measurements obtained by ultrasound. Additionally, hematological and serum biochemistry evaluations of the animals were performed. The ultrasound findings were similar to those available in the literature on domestic dogs, which were used for comparison as a result of the lack of published data regarding maned wolves. The latter species showed characteristics closely resembling those of the former, differing in the spleen and left renal cortex echogenicities, in the appearance of the prostatic and testicular regions and in the hepatic portal vein morphology. In the current study, the biometric values were similar to those previously published; however, no data regarding thoracic perimeter, modified crown-rump length or thoracic depth were found in the literature for this Canidae species. Statistical analysis showed the existence of a strong negative correlation between the modified crown-rump length and left renal length, between the modified crown-rump length and the right renal volume, between the thoracic perimeter and the height at the cranial pole of the left adrenal gland and between the thoracic perimeter and the height at the caudal pole of the left adrenal gland. Laboratory findings, including segmented neutrophil, eosinophil, monocyte and lymphocyte counts and the serum levels of glucose, ALT, alkaline phosphatase, urea, total protein, globulin, creatine phosphokinase, triglyceride, sodium

  10. Ultrasound evaluation of the abductor hallucis muscle: Reliability study

    Directory of Open Access Journals (Sweden)

    Hing Wayne A

    2008-09-01

    Full Text Available Abstract Background The Abductor hallucis muscle (AbdH plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Results The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99; medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97 and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99. Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98; medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96 and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88. Conclusion Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

  11. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  12. Intravascular Papillary Endothelial Hyperplasia Associated with Venous Pool Arising in the Lower Lip: A Case Report

    Directory of Open Access Journals (Sweden)

    Hisanobu Yonezawa

    2009-01-01

    Full Text Available Intravascular papillary endothelial hyperplasia is a benign nonneoplastic vascular lesion that consists of endothelial cells with abundant vascular tissue with papillary proliferation. An adult female had a painless growing dark red nodule on the left side of the lower lip and often touched and gnawed at it for more than 4 years. The lesion was a tender, smooth mass approximately 1 cm in diameter without discoloration reaction. Magnetic resonance imaging of the lesion showed specific findings. She was diagnosed clinically as having mimicked hemangioma, and the lesion was totally excised under local anesthesia. Histopathological examination revealed that papillary proliferated endothelial cells with venous pool, and the lesion was diagnosed as intravascular papillary endothelial hyperplasia associated with venous pool. There has been no recurrence for more than 1 year. Despite the benign nature of this lesion, it could have been mistaken for a malignant tumor because of its clinical course and radiologic findings.

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  14. Acorrelation study between histological results and thyroid ultrasound findings. The TI-RADS classification.

    Science.gov (United States)

    García-Moncó Fernández, Carlos; Serrano-Moreno, Clara; Donnay-Candil, Sergio; Carrero-Alvaro, Juan

    2018-04-01

    There are several classifications based on thyroid ultrasound for selecting suspected malignant thyroid nodules. The Thyroid Imaging Reporting and Data System (TI-RADS) classification proposed by Horvath in 2009 includes 6 categories. To assess the sensitivity of the TI-RADS classification for diagnosing thyroid nodules. A retrospective study of all patients who underwent thyroidectomy at our hospital (n=263) from September 2013 to December 2015. After thyroidectomy, histological results were correlated to the ultrasound findings reported. Of the 263 study patients, 75 (28.5%) were diagnosed with thyroid cancer and 188 (71.5%) with benign disease. Correlation of histological results with preoperative ultrasound reports showed an initial sensitivity of 65%. After excluding 15 patients diagnosed with occult microcarcinoma, sensitivity increased to 81.6%. The ultrasound images from 11 false negatives cases were then reassessed by a radiologist who knew histological diagnosis and reclassified 10 of them as TI-RADS≥4. This procedure could have increased sensitivity up to 98.3%. Although the sensitivity initially found in our study using the TI-RADS scale was relatively low, the value markedly improved when patients with occult microcarcinoma were excluded. Thus, use of the TI-RADS scale would allow for an adequate selection of patients amenable to fine needle aspiration of the nodule. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging produces pictures of the internal organs and blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ...

  16. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    Energy Technology Data Exchange (ETDEWEB)

    Slapa, Rafal Z., E-mail: rz.slapa@gmail.com [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Kasperlik–Zaluska, Anna A. [Endocrinology Department, Center for Postgraduate Medical Education, Bielanski Hospital, Warsaw (Poland); Migda, Bartosz [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Otto, Maciej [Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, First Faculty of Medicine, Warsaw (Poland); Jakubowski, Wiesław S. [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland)

    2015-08-15

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients.

  17. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    International Nuclear Information System (INIS)

    Slapa, Rafal Z.; Kasperlik–Zaluska, Anna A.; Migda, Bartosz; Otto, Maciej; Jakubowski, Wiesław S.

    2015-01-01

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients

  18. MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Lin; Kien Ng, Sook; Zhang, Ying; Herman, Joseph; Wong, John; Ding, Kai [Department of Radiation Oncology, John Hopkins University, Baltimore, MD (United States); Ji, Tianlong [Department of Radiation Oncology, The First Hospital of China Medical University, Shenyang, Liaoning (China); Iordachita, Iulian [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD (United States); Tutkun Sen, H.; Kazanzides, Peter; Lediju Bell, Muyinatu A. [Department of Computer Science, Johns Hopkins University, Baltimore, MD (United States)

    2016-06-15

    Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion. The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC

  19. MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Su, Lin; Kien Ng, Sook; Zhang, Ying; Herman, Joseph; Wong, John; Ding, Kai; Ji, Tianlong; Iordachita, Iulian; Tutkun Sen, H.; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2016-01-01

    Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion. The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC

  20. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  1. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  2. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    Science.gov (United States)

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at

  3. Ultrasound call detection in capybara

    Directory of Open Access Journals (Sweden)

    Selene S.C. Nogueira

    2012-07-01

    Full Text Available The vocal repertoire of some animal species has been considered a non-invasive tool to predict distress reactivity. In rats ultrasound emissions were reported as distress indicator. Capybaras[ vocal repertoire was reported recently and seems to have ultrasound calls, but this has not yet been confirmed. Thus, in order to check if a poor state of welfare was linked to ultrasound calls in the capybara vocal repertoire, the aim of this study was to track the presence of ultrasound emissions in 11 animals under three conditions: 1 unrestrained; 2 intermediately restrained, and 3 highly restrained. The ultrasound track identified frequencies in the range of 31.8±3.5 kHz in adults and 33.2±8.5 kHz in juveniles. These ultrasound frequencies occurred only when animals were highly restrained, physically restrained or injured during handling. We concluded that these calls with ultrasound components are related to pain and restraint because they did not occur when animals were free of restraint. Thus we suggest that this vocalization may be used as an additional tool to assess capybaras[ welfare.

  4. Magnetic Resonance-Guided High-Intensity-Focused Ultrasound for Palliation of Painful Skeletal Metastases: A Pilot Study.

    Science.gov (United States)

    Chan, Michael; Dennis, Kristopher; Huang, Yuexi; Mougenot, Charles; Chow, Edward; DeAngelis, Carlo; Coccagna, Jennifer; Sahgal, Arjun; Hynynen, Kullervo; Czarnota, Gregory; Chu, William

    2017-10-01

    Bone is one of the most common sites of metastases, with bone metastases-related pain representing a significant source of morbidity among patients with cancer. Magnetic resonance-guided focused ultrasound is a noninvasive, outpatient modality with the potential for treating painful bone metastases. The aim of this study is to report our initial experience with magnetic resonance-guided focused ultrasound in the treatment of bone metastases and our preliminary analysis of urinary cytokine levels after therapy. This was a single-center pilot study of 10 patients with metastatic cancer to investigate the feasibility of magnetic resonance-guided focused ultrasound for primary pain control in device-accessible skeletal metastases. Treatments were performed on a clinical magnetic resonance-guided focused ultrasound system using a volumetric ablation technique. Primary efficacy was assessed using Brief Pain Inventory scores and morphine equivalent daily dose intake at 3 time points: before, day 14, and day 30 after the magnetic resonance-guided focused ultrasound treatment. Urine cytokines were measured 3 days before treatment and 2 days after the treatment. Of the 10 patients, 8 were followed up 14 days and 6 were followed up 30 days after the treatment. At day 14, 3 patients (37.5%) exhibited partial pain response and 4 patients (50%) exhibited an indeterminate response, and at day 30 after the treatment, 5 patients (83%) exhibited partial pain response. No treatment-related adverse events were recorded. Of the urine cytokines measured, only Transforming growth factor alpha (TGFα) demonstrated an overall decrease, with a trend toward statistical significance ( P = .078). Our study corroborates magnetic resonance-guided focused ultrasound as a feasible and safe modality as a primary, palliative treatment for painful bone metastases and contributes to the limited body of literature using magnetic resonance-guided focused ultrasound for this clinical indication.

  5. Basic study on apoptosis induction into cancer cells U-937 and EL-4 by ultrasound exposure.

    Science.gov (United States)

    Takeuchi, Shinichi; Udagawa, Yoshiko; Oku, Yumiko; Fujii, Takuma; Nishimura, Hiroyuki; Kawashima, Norimichi

    2006-12-22

    Recently, the low invasive cancer treatments with small aftereffects have been considered. We are studying on the suppression methods of cancer cell proliferation with ultrasound. Cancer cells of mouse T lymphoma (EL-4) have been used in our study. The human histitocytic lymphoma cells (U-937) was used in this time. The cancer cells were cultured in a culture medium of RPMI1640. The standing wave acoustic field was formed in a water tank of our ultrasound exposure system by a vibrating plate driven with a Langevine type transducer. The U-937 and EL-4 were exposed to ultrasound in the acoustic field with spatial average acoustic intensity of 350 mW/cm(2) at 150 kHz. The viable rate of EL-4 decreased with the lapse of culture time after ultrasound exposure. U-937 did not show the remarkable decrease tendency. The proliferation of U-937 which exposed to ultrasound with 700 mW/cm(2) was suppressed. It can be thought that apoptosis was induced in the cancer cells in this condition. We observed the morphological change on the U-937 exposed to ultrasound with this condition. The morphological changes by apoptosis like the shrink of cells, formation of apoptotic bodies etc. can be observed with an optical microscope and a phase contrast microscope.

  6. Dependence of the frequency spectrum of small amplitude vibrations superimposed on finite deformations of a nonlinear, cylindrical elastic body on residual stress

    KAUST Repository

    Gorb, Yuliya; Walton, Jay R.

    2010-01-01

    We model and analyze the response of nonlinear, residually stressed elastic bodies subjected to small amplitude vibrations superimposed upon large deformations. The problem derives from modeling the use of intravascular ultrasound (IVUS) imaging

  7. Impact of ultrasound video transfer on the practice of ultrasound

    Science.gov (United States)

    Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh

    1996-05-01

    Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.

  8. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help ... tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study ...

  10. Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

    Energy Technology Data Exchange (ETDEWEB)

    Nabili, Marjan, E-mail: mnabili@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, 800 22nd Street NW, Room 5000, Washington, DC 20052 (United States); Geist, Craig, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu [Department of Ophthalmology, The George Washington University, 2150 Pennsylvania Avenue NW, Floor 2A, Washington, DC 20037 (United States); Zderic, Vesna, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu [Department of Biomedical Engineering, The George Washington University, 800 22nd Street NW, Room 6670, Washington, DC 20052 (United States)

    2015-10-15

    Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm{sup 2}, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm{sup 2} (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety

  11. Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

    International Nuclear Information System (INIS)

    Nabili, Marjan; Geist, Craig; Zderic, Vesna

    2015-01-01

    Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm 2 , and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm 2 (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this

  12. Plaque Structural Stress Estimations Improve Prediction of Future Major Adverse Cardiovascular Events After Intracoronary Imaging.

    Science.gov (United States)

    Brown, Adam J; Teng, Zhongzhao; Calvert, Patrick A; Rajani, Nikil K; Hennessy, Orla; Nerlekar, Nitesh; Obaid, Daniel R; Costopoulos, Charis; Huang, Yuan; Hoole, Stephen P; Goddard, Martin; West, Nick E J; Gillard, Jonathan H; Bennett, Martin R

    2016-06-01

    Although plaque rupture is responsible for most myocardial infarctions, few high-risk plaques identified by intracoronary imaging actually result in future major adverse cardiovascular events (MACE). Nonimaging markers of individual plaque behavior are therefore required. Rupture occurs when plaque structural stress (PSS) exceeds material strength. We therefore assessed whether PSS could predict future MACE in high-risk nonculprit lesions identified on virtual-histology intravascular ultrasound. Baseline nonculprit lesion features associated with MACE during long-term follow-up (median: 1115 days) were determined in 170 patients undergoing 3-vessel virtual-histology intravascular ultrasound. MACE was associated with plaque burden ≥70% (hazard ratio: 8.6; 95% confidence interval, 2.5-30.6; P<0.001) and minimal luminal area ≤4 mm(2) (hazard ratio: 6.6; 95% confidence interval, 2.1-20.1; P=0.036), although absolute event rates for high-risk lesions remained <10%. PSS derived from virtual-histology intravascular ultrasound was subsequently estimated in nonculprit lesions responsible for MACE (n=22) versus matched control lesions (n=22). PSS showed marked heterogeneity across and between similar lesions but was significantly increased in MACE lesions at high-risk regions, including plaque burden ≥70% (13.9±11.5 versus 10.2±4.7; P<0.001) and thin-cap fibroatheroma (14.0±8.9 versus 11.6±4.5; P=0.02). Furthermore, PSS improved the ability of virtual-histology intravascular ultrasound to predict MACE in plaques with plaque burden ≥70% (adjusted log-rank, P=0.003) and minimal luminal area ≤4 mm(2) (P=0.002). Plaques responsible for MACE had larger superficial calcium inclusions, which acted to increase PSS (P<0.05). Baseline PSS is increased in plaques responsible for MACE and improves the ability of intracoronary imaging to predict events. Biomechanical modeling may complement plaque imaging for risk stratification of coronary nonculprit lesions. © 2016

  13. The role of the adventitia in the arterial response to angioplasty: the effect of intravascular radiation

    International Nuclear Information System (INIS)

    Wilcox, Josiah N.; Waksman, Ron; King, Spencer B.; Scott, Neal A.

    1996-01-01

    Purpose: In the current series of experiments we have characterized cell proliferation leading to vascular lesion formation in a porcine model for post-angioplasty restenosis and examined the mechanism of action of intravascular beta irradiation in the prevention of lesion formation in this model. Methods and Materials: Juvenile male pigs were subjected to balloon overstretch injury of the left anterior descending and circumflex coronary arteries using clinical angioplasty catheters. Proliferating cells were labelled by injections of 50 mg/kg of bromo-deoxyuridine (BrDU) 24, 16 and 8 hrs prior to sacrifice and were detected by immunohistochemistry using a specific antibody to BrDU. In some cases, BrDU was given as a pulse 3 days after angioplasty and the animals sacrificed on day 14 to follow the migration of the cells which had proliferated earlier. Characterization of the proliferating cells was performed by immunohistochemistry using antibodies to specific cytoskeletal proteins specific for smooth muscle cells and myofibroblasts. Some vessels were treated at the time of angioplasty with 14 or 28 Gy (to a depth of 2 mm) intravascular irradiation using a flexible catheter with a pure beta emitter 90 SR/Y and the effect on cell proliferation and terminal transferase-mediated UTP nick-end labelling (TUNEL) examined 3 or 7 days later. Results: The first major site of cell proliferation between 2-3 days after angioplasty is the adventitia and not the medial wall. Seven days after angioplasty cell proliferation is predominant in the neointima and is reduced in the media and adventitia. Differential staining with antibodies directed against smooth muscle alpha actin and other cytoskeletal proteins indicates that the proliferating adventitial cells are myofibroblasts. Pulse label studies with BrDU indicates that the proliferating adventitial myofibroblasts migrate into the neointima and contribute to the mass of the restenosis lesion. Fourteen days after angioplasty the

  14. Ultrasound applicability in Speech Language Pathology and Audiology.

    Science.gov (United States)

    Barberena, Luciana da Silva; Brasil, Brunah de Castro; Melo, Roberta Michelon; Mezzomo, Carolina Lisbôa; Mota, Helena Bolli; Keske-Soares, Márcia

    2014-01-01

    To present recent studies that used the ultrasound in the fields of Speech Language Pathology and Audiology, which evidence possibilities of the applicability of this technique in different subareas. A bibliographic research was carried out in the PubMed database, using the keywords "ultrasonic," "speech," "phonetics," "Speech, Language and Hearing Sciences," "voice," "deglutition," and "myofunctional therapy," comprising some areas of Speech Language Pathology and Audiology Sciences. The keywords "ultrasound," "ultrasonography," "swallow," "orofacial myofunctional therapy," and "orofacial myology" were also used in the search. Studies in humans from the past 5 years were selected. In the preselection, duplicated studies, articles not fully available, and those that did not present direct relation between ultrasound and Speech Language Pathology and Audiology Sciences were discarded. The data were analyzed descriptively and classified subareas of Speech Language Pathology and Audiology Sciences. The following items were considered: purposes, participants, procedures, and results. We selected 12 articles for ultrasound versus speech/phonetics subarea, 5 for ultrasound versus voice, 1 for ultrasound versus muscles of mastication, and 10 for ultrasound versus swallow. Studies relating "ultrasound" and "Speech Language Pathology and Audiology Sciences" in the past 5 years were not found. Different studies on the use of ultrasound in Speech Language Pathology and Audiology Sciences were found. Each of them, according to its purpose, confirms new possibilities of the use of this instrument in the several subareas, aiming at a more accurate diagnosis and new evaluative and therapeutic possibilities.

  15. Quantitative ultrasound characterization of tumor cell death: ultrasound-stimulated microbubbles for radiation enhancement.

    Directory of Open Access Journals (Sweden)

    Hyunjung Christina Kim

    Full Text Available The aim of this study was to assess the efficacy of quantitative ultrasound imaging in characterizing cancer cell death caused by enhanced radiation treatments. This investigation focused on developing this ultrasound modality as an imaging-based non-invasive method that can be used to monitor therapeutic ultrasound and radiation effects. High-frequency (25 MHz ultrasound was used to image tumor responses caused by ultrasound-stimulated microbubbles in combination with radiation. Human prostate xenografts grown in severe combined immunodeficiency (SCID mice were treated using 8, 80, or 1000 µL/kg of microbubbles stimulated with ultrasound at 250, 570, or 750 kPa, and exposed to 0, 2, or 8 Gy of radiation. Tumors were imaged prior to treatment and 24 hours after treatment. Spectral analysis of images acquired from treated tumors revealed overall increases in ultrasound backscatter intensity and the spectral intercept parameter. The increase in backscatter intensity compared to the control ranged from 1.9±1.6 dB for the clinical imaging dose of microbubbles (8 µL/kg, 250 kPa, 2 Gy to 7.0±4.1 dB for the most extreme treatment condition (1000 µL/kg, 750 kPa, 8 Gy. In parallel, in situ end-labelling (ISEL staining, ceramide, and cyclophilin A staining demonstrated increases in cell death due to DNA fragmentation, ceramide-mediated apoptosis, and release of cyclophilin A as a result of cell membrane permeabilization, respectively. Quantitative ultrasound results indicated changes that paralleled increases in cell death observed from histology analyses supporting its use for non-invasive monitoring of cancer treatment outcomes.

  16. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  17. Emerging Technology Update Intravascular Photoacoustic Imaging of Vulnerable Atherosclerotic Plaque.

    Science.gov (United States)

    Wu, Min; Fw van der Steen, Antonius; Regar, Evelyn; van Soest, Gijs

    2016-10-01

    The identification of vulnerable atherosclerotic plaques in the coronary arteries is emerging as an important tool for guiding atherosclerosis diagnosis and interventions. Assessment of plaque vulnerability requires knowledge of both the structure and composition of the plaque. Intravascular photoacoustic (IVPA) imaging is able to show the morphology and composition of atherosclerotic plaque. With imminent improvements in IVPA imaging, it is becoming possible to assess human coronary artery disease in vivo . Although some challenges remain, IVPA imaging is on its way to being a powerful tool for visualising coronary atherosclerotic features that have been specifically associated with plaque vulnerability and clinical syndromes, and thus such imaging might become valuable for clinical risk assessment in the catheterisation laboratory.

  18. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    Science.gov (United States)

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  19. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial.

    Science.gov (United States)

    Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W

    2016-11-26

    Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural

  20. Is the inferior vena cava diameter measured by bedside ultrasonography valuable in estimating the intravascular volume in patients with septic shock?

    Directory of Open Access Journals (Sweden)

    Mortaza Talebi Doluie

    2016-07-01

    Full Text Available Introduction:Resuscitation should be initiated immediately in shock. Early goal-directed therapy is an established algorithm for the resuscitation in septic shock. The first step is to maintain cardiac preload. Central venous pressure (CVP plays an important role in goal-directed therapy. Central venous catheterization is invasive and time-consuming in emergency conditions. There are some alternative and noninvasive methods for estimating the intravascular volume such as measuring the inferior vena cava (IVC diameter by ultrasonography. Methods: We searched PubMed, Google scholar, and Scopus databases with keywords (central venous pressure OR venous pressure OR CVP AND (ultrasonography OR sonography AND (sepsis OR septic shock AND (inferior vena cava OR IVC.Result: The search resulted in 2550 articles. The articles were appraised regarding the relevance, type of article, and statistical methods. Finally, 12 articles were selected. The number of patients was between 30 and 83 cases (mean age=57-67 years, intubated and non-intubated in each study. The IVC diameter was measured in respiratory cycle by bedside ultrasonography in longitudinal subxiphoid view and caval index was calculated, then they were compared with the CVP measured by central venous catheter.Discussion: CVP is an indicator of intravascular fluid status and right heart function. CVP measurement is an invasive method and of course with some complications. The IVC is the biggest vein of venous system with low-pressure; expansion of the vein reflects intravascular volume.Conclusion: It seems that IVC diameter measured by ultrasonography could be used as an alternative method for the determination of CVP in the emergency or critical patients.

  1. In vivo demonstration of ultrasound power delivery to charge implanted medical devices via acute and survival porcine studies.

    Science.gov (United States)

    Radziemski, Leon; Makin, Inder Raj S

    2016-01-01

    Animal studies are an important step in proving the utility and safety of an ultrasound based implanted battery recharging system. To this end an Ultrasound Electrical Recharging System (USER™) was developed and tested. Experiments in vitro demonstrated power deliveries at the battery of up to 600 mW through 10-15 mm of tissue, 50 mW of power available at tissue depths of up to 50 mm, and the feasibility of using transducers bonded to titanium as used in medical implants. Acute in vivo studies in a porcine model were used to test reliability of power delivery, temperature excursions, and cooling techniques. The culminating five-week survival study involved repeated battery charging, a total of 10.5h of ultrasound exposure of the intervening living tissue, with an average RF input to electrical charging efficiency of 20%. This study was potentially the first long term cumulative living-tissue exposure using transcutaneous ultrasound power transmission to an implanted receiver in situ. Histology of the exposed tissue showed changes attributable primarily due to surgical implantation of the prototype device, and no damage due to the ultrasound exposure. The in vivo results are indicative of the potential safe delivery of ultrasound energy for a defined set of source conditions for charging batteries within implants. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Nonthermal ablation with microbubble-enhanced focused ultrasound close to the optic tract without affecting nerve function.

    Science.gov (United States)

    McDannold, Nathan; Zhang, Yong-Zhi; Power, Chanikarn; Jolesz, Ferenc; Vykhodtseva, Natalia

    2013-11-01

    Tumors at the skull base are challenging for both resection and radiosurgery given the presence of critical adjacent structures, such as cranial nerves, blood vessels, and brainstem. Magnetic resonance imaging-guided thermal ablation via laser or other methods has been evaluated as a minimally invasive alternative to these techniques in the brain. Focused ultrasound (FUS) offers a noninvasive method of thermal ablation; however, skull heating limits currently available technology to ablation at regions distant from the skull bone. Here, the authors evaluated a method that circumvents this problem by combining the FUS exposures with injected microbubble-based ultrasound contrast agent. These microbubbles concentrate the ultrasound-induced effects on the vasculature, enabling an ablation method that does not cause significant heating of the brain or skull. In 29 rats, a 525-kHz FUS transducer was used to ablate tissue structures at the skull base that were centered on or adjacent to the optic tract or chiasm. Low-intensity, low-duty-cycle ultrasound exposures (sonications) were applied for 5 minutes after intravenous injection of an ultrasound contrast agent (Definity, Lantheus Medical Imaging Inc.). Using histological analysis and visual evoked potential (VEP) measurements, the authors determined whether structural or functional damage was induced in the optic tract or chiasm. Overall, while the sonications produced a well-defined lesion in the gray matter targets, the adjacent tract and chiasm had comparatively little or no damage. No significant changes (p > 0.05) were found in the magnitude or latency of the VEP recordings, either immediately after sonication or at later times up to 4 weeks after sonication, and no delayed effects were evident in the histological features of the optic nerve and retina. This technique, which selectively targets the intravascular microbubbles, appears to be a promising method of noninvasively producing sharply demarcated lesions in

  3. Crystallization of glycine with ultrasound

    DEFF Research Database (Denmark)

    Louhi-Kultanen, Marjatta; Karjalainen, Milja; Rantanen, Jukka

    2006-01-01

    Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound with an ultr...... ultrasound power. This study also showed, the higher the ultrasound amplitude the smaller the crystals obtained.......Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound...... with an ultrasound frequency of 20kHz at two temperature ranges 40-50 and 20-30 degrees C in a jacketed 250-ml cooling crystallizer equipped with a stirrer. The polymorph composition of the obtained crystals was analyzed with a temperature variable X-ray powder diffractometer (XRPD). XRPD results showed that...

  4. Life-threatening urethral hemorrhage after placement of a Foley catheter in a patient with uroseptic disseminated intravascular coagulation due to chronic urinary retention induced by untreated benign prostatic hyperplasia.

    Science.gov (United States)

    Ikegami, Yukihiro; Yoshida, Keisuke; Imaizumi, Tsuyoshi; Isosu, Tsuyoshi; Kurosawa, Shin; Murakawa, Masahiro

    2016-10-01

    A 77-year-old man with severe septic disseminated intravascular coagulation following urinary infection was transported to our hospital. He had developed urinary retention induced by untreated prostatic hyperplasia. Immediate drainage with a Foley catheter was successfully carried out, but the hematuria progressed to life-threatening hemorrhage. Complete hemostasis was impossible by surgical treatment because the tissue around the prostatic urethra was very fragile and hemorrhagic. Organized treatments (continuous hemodiafiltration combined with polymyxin-B immobilized fiber column hemoperfusion and systemic treatment with antibiotics and coagulation factors) were commenced soon after the operation. The patient eventually recovered from the septic disseminated intravascular coagulation. This case report illustrates the risk of placement of Foley catheters in patients with severe septic disseminated intravascular coagulation.

  5. Ultrasound analysis of mental artery flow in elderly patients: a case-control study.

    Science.gov (United States)

    Baladi, Marina G; Tucunduva Neto, Raul R C M; Cortes, Arthur R G; Aoki, Eduardo M; Arita, Emiko S; Freitas, Claudio F

    2015-01-01

    Mental artery flow decreases with age and may have an aetiological role in alveolar ridge atrophy. The aim of this study was to identify factors associated with alterations of mental artery flow, assessed by ultrasonography. This case-control study was conducted on elderly patients (aged above 60 years) at the beginning of dental treatment. Intraoral B-mode Doppler ultrasonography was used to assess mental artery flow. The cases were defined as patients with a weak/absent ultrasound signal, whereas the controls presented a strong ultrasound signal. Demographics and radiographic findings (low bone mineral density on dual-energy X-ray absorptiometry and mandibular cortical index on panoramic radiographs) were analysed as risk factors for weak/absent ultrasound signal and were calculated as adjusted odds ratios (AORs) with 95% confidence intervals (CIs) using conditional logistic regression. In addition, the Student's t-test was used to compare the mean alveolar bone height of the analysed groups. A p-value <0.05 was considered statistically significant. A total of 30 ultrasound examinations (12 cases and 18 controls) were analysed. A weak/absent mental artery pulse strength was significantly associated with edentulism (AOR = 3.67; 95% CI = 0.86-15.63; p = 0.046). In addition, there was a significant difference in alveolar bone height between edentulous cases and controls (p = 0.036). Within the limitations of this study, the present results indicate that edentulism is associated with diminished mental artery flow, which, in turn, affects alveolar bone height.

  6. Ultrasound analysis of mental artery flow in elderly patients: a case–control study

    Science.gov (United States)

    Baladi, Marina G; Tucunduva Neto, Raul R C M; Aoki, Eduardo M; Arita, Emiko S; Freitas, Claudio F

    2015-01-01

    Objectives: Mental artery flow decreases with age and may have an aetiological role in alveolar ridge atrophy. The aim of this study was to identify factors associated with alterations of mental artery flow, assessed by ultrasonography. Methods: This case–control study was conducted on elderly patients (aged above 60 years) at the beginning of dental treatment. Intraoral B-mode Doppler ultrasonography was used to assess mental artery flow. The cases were defined as patients with a weak/absent ultrasound signal, whereas the controls presented a strong ultrasound signal. Demographics and radiographic findings (low bone mineral density on dual-energy X-ray absorptiometry and mandibular cortical index on panoramic radiographs) were analysed as risk factors for weak/absent ultrasound signal and were calculated as adjusted odds ratios (AORs) with 95% confidence intervals (CIs) using conditional logistic regression. In addition, the Student's t-test was used to compare the mean alveolar bone height of the analysed groups. A p-value <0.05 was considered statistically significant. Results: A total of 30 ultrasound examinations (12 cases and 18 controls) were analysed. A weak/absent mental artery pulse strength was significantly associated with edentulism (AOR = 3.67; 95% CI = 0.86–15.63; p = 0.046). In addition, there was a significant difference in alveolar bone height between edentulous cases and controls (p = 0.036). Conclusions: Within the limitations of this study, the present results indicate that edentulism is associated with diminished mental artery flow, which, in turn, affects alveolar bone height. PMID:26205777

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  10. Ultrasound-guided brachial plexus block: a study on 30 patients

    Directory of Open Access Journals (Sweden)

    Amiri HR

    2009-05-01

    Full Text Available "n Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Successful brachial plexus blocks rely on proper techniques of nerve localization, needle placement, and local anesthetic injection. Standard approaches used today (elicitation of paresthesia or nerve-stimulated muscle contraction, unfortunately, are all "blind" techniques resulting in procedure-related pain and complications. Ultrasound guidance for brachial plexus blocks can potentially improve success and complication rates. This study presents the ultrasound-guided brachial plexus blocks for the first time in Iran in adults and pediatrics. "n"n Methods: In this study ultrasound-guided brachial plexus blocks in 30 patients (25 adults & 5 pediatrics scheduled for an elective upper extremity surgery, are introduced. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. Besides basic variables, block approach, block time, postoperative analgesia duration (VAS<3 was considered as target pain control opioid consumption during surgery, patient satisfaction and block related complications were reported

  11. The Diagnosis of Spontaneous Coronary Artery Dissection by Optical Coherence Tomography.

    Science.gov (United States)

    Kanda, Takahiro; Tawarahara, Kei; Matsukura, Gaku; Matsunari, Masayoshi; Takabayashi, Rumi; Tamura, Jun; Ozeki, Mariko; Ukigai, Hiroshi

    2018-02-15

    Spontaneous coronary artery dissection (SCAD) is rare, but it frequently presents as acute myocardial infarction. It is frequently fatal and most cases are diagnosed at autopsy. We herein present the case of a 65-year-old woman with ST-elevation and myocardial infarction due to SCAD. Optical coherence tomography (OCT) helped us to confirm the diagnosis. The information on the intravascular morphology provided by OCT imaging is much more detailed in comparison to that provided by coronary angiography (CAG) and intravascular ultrasound (IVUS).

  12. Research interface on a programmable ultrasound scanner.

    Science.gov (United States)

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research

  13. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  14. Ultrasound-guided block of the suprascapular nerve - a volunteer study of a new proximal approach

    DEFF Research Database (Denmark)

    Rothe, C; Steen-Hansen, C; Lund, J

    2014-01-01

    BACKGROUND: The standard approach for the suprascapular nerve block is deep in the supraspinous fossa. However, with this approach, the suprascapular nerve is difficult to visualize by ultrasound. The aim of this study was to describe a new method to visualize and selectively block the suprascapu......BACKGROUND: The standard approach for the suprascapular nerve block is deep in the supraspinous fossa. However, with this approach, the suprascapular nerve is difficult to visualize by ultrasound. The aim of this study was to describe a new method to visualize and selectively block...... the suprascapular nerve in a more superficial and proximal location. METHODS: Twelve healthy volunteers were included. We located the brachial plexus in transverse section with ultrasound, and by longitudinal slide, we identified the departure of the suprascapular nerve from the superior trunk. The suprascapular...

  15. Using Ultrasound to Teach Medical Students Cardiac Physiology

    Science.gov (United States)

    Bell, Floyd E., III; Wilson, L. Britt; Hoppmann, Richard A.

    2015-01-01

    Ultrasound is being incorporated more into undergraduate medical education. Studies have shown that medical students have positive perceptions about the value of ultrasound in teaching courses like anatomy and physiology. The purpose of the present study was to provide objective evidence of whether ultrasound helps students learn cardiac…

  16. Performance of chest ultrasound in pediatric pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Claes, Anne-Sophie, E-mail: anso.claes@gmail.com [Departement of Radiology, Pediatric and Thoracic Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Clapuyt, Philippe, E-mail: philippe.clapuyt@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Menten, Renaud, E-mail: renaud.menten@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Michoux, Nicolas, E-mail: nicolas.michoux@uclouvain.be [Departement of Radiology, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Dumitriu, Dana, E-mail: dana.dumitriu@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2017-03-15

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  17. Performance of chest ultrasound in pediatric pneumonia

    International Nuclear Information System (INIS)

    Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana

    2017-01-01

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  18. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  19. Ultrasound diagnosis of rectus sheath hematoma

    International Nuclear Information System (INIS)

    Hwang, M. S.; Chang, J. C.; Rhee, C. B.

    1984-01-01

    6 cases of rectus sheath hematoma were correctly diagnosed by ultrasound. 2 cases had bilateral rectus sheath hematoma and 4 cases were unilateral. On ultrasound finding, relatively well defined oval or spindle like cystic mass situated in the area of rectus muscle on all cases. Ultrasound examination may give more definite diagnosis and extension rectus sheath hematoma and also helpful to follow up study of hematoma

  20. A Randomized, Double-Blind, Placebo-Controlled, Phase 2b Study to Evaluate the Safety and Efficacy of Recombinant Human Soluble Thrombomodulin, ART-123, in Patients With Sepsis and Suspected Disseminated Intravascular Coagulation

    NARCIS (Netherlands)

    Vincent, Jean-Louis; Ramesh, Mayakonda K.; Ernest, David; Larosa, Steven P.; Pachl, Jan; Aikawa, Naoki; Hoste, Eric; Levy, Howard; Hirman, Joe; Levi, Marcel; Daga, Mradul; Kutsogiannis, Demetrios J.; Crowther, Mark; Bernard, Gordon R.; Devriendt, Jacques; Puigserver, Joan Vidal; Blanzaco, Daniel U.; Esmon, Charles T.; Parrillo, Joseph E.; Guzzi, Louis; Henderson, Seton J.; Pothirat, Chaicharn; Mehta, Parthiv; Fareed, Jawed; Talwar, Deepak; Tsuruta, Kazuhisa; Gorelick, Kenneth J.; Osawa, Yutaka; Kaul, Inder

    2013-01-01

    Objectives: To determine the safety and efficacy of recombinant thrombomodulin (ART-123) in patients with suspected sepsis-associated disseminated intravascular coagulation. Design: Phase 2b, international, multicenter, double-blind, randomized, placebo-controlled, parallel group, screening trial.

  1. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis.

    Science.gov (United States)

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-04-07

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC.

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  3. Performance of Bedside Lung Ultrasound by a Pediatric Resident

    DEFF Research Database (Denmark)

    Zhan, Chen; Grundtvig, Natalia; Klug, Bent Helmuth

    2017-01-01

    OBJECTIVES: Recent studies suggest that lung ultrasound is a good, radiation-free alternative to chest radiography in children with pneumonia. We investigated how bedside lung ultrasound performed by a pediatric resident compared with chest radiography in children with suspected pneumonia. METHODS......: This was a prospective study comparing bedside lung ultrasound to chest radiography as the reference standard. Children aged 0 to 15 years with suspected pneumonia at a pediatric emergency department were included and underwent chest radiography and lung ultrasound. A pediatric resident with minimal practical ultrasound...

  4. Intravascular trans-catheter fibrinolysis in acute arterial obstructions

    International Nuclear Information System (INIS)

    Roversi, R.; Rossi, C.; Ricci, S.; Gemelli, G.; Ciliberti, M.A.

    1987-01-01

    The author's experiences is reported on intravascular fibrinolytic therapy with urokinase in acute arterial obstructions. Thirty-eight patients were treated, from 1983 to 1986, for acute thrombosis and/or thromboembolization, 22 of which developed on an atherosclerotic lesion, and 10 on a surgical stenotic by-pass graft. A complete vascular recanalization has been obtained, at the end of the procedure, in 69,4% of the cases, 77,7% had a definite final clinical improvement. The results correspond to the medium statistical of the various casistics analyzed for comparison. Surgery has been performed on 27,7% of the patients. Complication have been observed in 8% of the cases. IAF technique is of greatest value in the treatment of those lesions; better results have been obtained with intra-thrombus injection of the drug (as emphasized by many authors) in association with PTA and surgery. A close cooperation between interventional radiology, vascular surgery and angiology is therefore necessary in this field

  5. Primary intravascular large B-cell lymphoma of pituitary

    Directory of Open Access Journals (Sweden)

    K R Anila

    2012-01-01

    Full Text Available A 68-year-old retired nurse, who was a known hypertensive on medication, presented with prolonged fever of 2-month duration without any clinical evidence of infection. On examination she had altered mental status. She also had other nonspecific complaints such as sleep disturbances, loss of weight, etc. On investigation, she was found to have anemia, thrombocytopenia, raised erythrocyte sedimentation rate (ESR, C-reactive protein (CRP, and lactate dehydrogenase (LDH values. She also had electrolyte imbalance. Radiological evaluation of brain showed mass lesion in the sella turcica, suggestive of pituitary adenoma. Biochemical evaluation showed hypopituitarism. Trans-sphenoidal biopsy was done. Based on histopathological and immunohistochemical findings a diagnosis of intravascular large B-cell lymphoma (IVLBCL of pituitary was made. Our patient′s condition deteriorated rapidly and she succumbed to her illness before therapy could be initiated. We are reporting this case because of the rare subtype of large B-cell lymphoma presenting at an extremely unusual primary site.

  6. Droplets, Bubbles and Ultrasound Interactions

    NARCIS (Netherlands)

    Shpak, O.; Verweij, M.; de Jong, N.; Versluis, Michel; Escoffre, J.M.; Bouakaz, A.

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to

  7. Correction of systematic bias in ultrasound dating in studies of small-for-gestational-age birth: an example from the Iowa Health in Pregnancy Study.

    Science.gov (United States)

    Harland, Karisa K; Saftlas, Audrey F; Wallis, Anne B; Yankowitz, Jerome; Triche, Elizabeth W; Zimmerman, M Bridget

    2012-09-01

    The authors examined whether early ultrasound dating (≤20 weeks) of gestational age (GA) in small-for-gestational-age (SGA) fetuses may underestimate gestational duration and therefore the incidence of SGA birth. Within a population-based case-control study (May 2002-June 2005) of Iowa SGA births and preterm deliveries identified from birth records (n = 2,709), the authors illustrate a novel methodological approach with which to assess and correct for systematic underestimation of GA by early ultrasound in women with suspected SGA fetuses. After restricting the analysis to subjects with first-trimester prenatal care, a nonmissing date of the last menstrual period (LMP), and early ultrasound (n = 1,135), SGA subjects' ultrasound GA was 5.5 days less than their LMP GA, on average. Multivariable linear regression was conducted to determine the extent to which ultrasound GA predicted LMP dating and to correct for systematic misclassification that results after applying standard guidelines to adjudicate differences in these measures. In the unadjusted model, SGA subjects required a correction of +1.5 weeks to the ultrasound estimate. With adjustment for maternal age, smoking, and first-trimester vaginal bleeding, standard guidelines for adjudicating differences in ultrasound and LMP dating underestimated SGA birth by 12.9% and overestimated preterm delivery by 8.7%. This methodological approach can be applied by researchers using different study populations in similar research contexts.

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are ...

  9. Impact of prenatal ultrasound consultation on maternal anxiety

    International Nuclear Information System (INIS)

    Masroor, I.; Ajmal, F.; Ahmed, H.

    2008-01-01

    To determine whether ultrasound consultation reduces maternal anxiety and increases feto-maternal attachment ( the desire to care for the fetus and care for self). Patients coming for routine obstetric ultrasound at the Department of Radiology, Aga Khan University Hospital Karachi were recruited in the study. The study was carried out over the period of two months from January-February 2007 in which sixty patients were included in the study. Patients were randomly assigned to a standard care group or an ultrasound consultation group (30 patients in each arm). Both groups were required to fill a questionnaire before and after their ultrasound examination. The ultrasound consultation group in addition received counseling before they went in for the ultrasound regarding fetal development and maternal-fetal interaction. The two groups were then compared for difference of change in feto maternal attachment scores and change in anxiety levels regarding their pregnancies before and after the ultrasound. SPSS software (version 14) was used for compilation of the data and the statistical computations. Categorical data was compared using Chi-square test and continuous variables were analyzed with paired t-test. P value <0.05 was considered significant. A positive difference in feto-maternal attachment and reduction in anxiety levels was seen in both the groups but this difference was statistically significant in the ultrasound consultation group only. This study suggests that ultrasound examinations with prior consultation has a positive impact on patients as it strengthens bonding toward the fetus, reduces maternal anxiety and increases maternal investment in health during the pregnancy. (author)

  10. High resolution three-dimensional robotic synthetic tracked aperture ultrasound imaging: feasibility study

    Science.gov (United States)

    Zhang, Haichong K.; Fang, Ting Yun; Finocchi, Rodolfo; Boctor, Emad M.

    2017-03-01

    Three dimensional (3D) ultrasound imaging is becoming a standard mode for medical ultrasound diagnoses. Conventional 3D ultrasound imaging is mostly scanned either by using a two dimensional matrix array or by motorizing a one dimensional array in the elevation direction. However, the former system is not widely assessable due to its cost, and the latter one has limited resolution and field-of-view in the elevation axis. Here, we propose a 3D ultrasound imaging system based on the synthetic tracked aperture approach, in which a robotic arm is used to provide accurate tracking and motion. While the ultrasound probe is moved by a robotic arm, each probe position is tracked and can be used to reconstruct a wider field-of-view as there are no physical barriers that restrict the elevational scanning. At the same time, synthetic aperture beamforming provides a better resolution in the elevation axis. To synthesize the elevational information, the single focal point is regarded as the virtual element, and forward and backward delay-andsum are applied to the radio-frequency (RF) data collected through the volume. The concept is experimentally validated using a general ultrasound phantom, and the elevational resolution improvement of 2.54 and 2.13 times was measured at the target depths of 20 mm and 110 mm, respectively.

  11. Low-intensity pulsed ultrasound: Nonunions

    Directory of Open Access Journals (Sweden)

    Dijkman Bernadette

    2009-01-01

    Full Text Available Nonunions occur in 5-10% of fractures and are characterized by the failure to heal without further intervention. Low intensity pulsed ultrasound therapy has been developed as an alternative to surgery in the treatment of nonunions. We describe a systematic review on trials of low-intensity pulsed ultrasound therapy for healing of nonunions. We searched the electronic databases Medline and the Cochrane library for articles on ultrasound and healing of nonunions published up to 2008. Trials selected for the review met the following criteria: treatment of at least one intervention group with low intensity pulsed ultrasound; inclusion of patients (humans with one or more nonunions (defined as "established" or as a failure to heal for a minimum of eight months after initial injury; and assessment of healing and time to healing, as determined radiographically. The following data were abstracted from the included studies: sample size, ultrasound treatment characteristics, nonunion location, healing rate, time to fracture healing, fracture age, and demographic information. We found 79 potentially eligible publications, of which 14 met our inclusion criteria. Of these, eight studies were used for data abstraction. Healing rates averaged 87%, (range 65.6%-100% among eight trials. Mean time to healing was 146.5 days, (range 56-219 days. There is evidence from trials that low-intensity pulsed ultrasound may be an effective treatment for healing of nonunions. More homogeneous and larger controlled series are needed to further investigate its efficacy.

  12. [Intravascular Hemolysis Caused by Stenosis of an Elephant Trunk;Report of a Case].

    Science.gov (United States)

    Takamaru, Rikako; Kawahito, Koji; Aizawa, Kei; Misawa, Yoshio

    2017-07-01

    Symptomatic intravascular hemolysis after prosthetic aortic graft replacement is rare. It is primarily attributed to mechanical injury of red blood cells caused by stenosis of the vascular graft. A 50-year-old man presented with hemolytic anemia, 5 years after total arch replacement with an elephant trunk for type A aortic dissection. The hemolysis was caused by graft stenosis of the elephant trunk. Endovascular treatment for the stenotic elephant trunk was successfully performed. The postoperative course was uneventful, and the hemolysis was resolved immediately after operation.

  13. Compensatory enlargement of the left main coronary artery: insights from the PROSPECT study.

    Science.gov (United States)

    Inaba, Shinji; Mintz, Gary S; Shimizu, Takehisa; Weisz, Giora; Mehran, Roxana; Marso, Steven P; Xu, Ke; de Bruyne, Bernard; Serruys, Patrick W; Stone, Gregg W; Maehara, Akiko

    2014-03-01

    Glagov proposed that remodeling delayed development of significant coronary artery stenoses until plaque occupied, on average, 40% of arterial area (40% plaque burden). The aim of the current study was to confirm the previously proposed concept of coronary remodeling as first described by Glagov who studied postmortem left main coronary arteries (LMCAs). Using the in-vivo intravascular ultrasound data from the Providing Regional Observations to Study Predictors of Events in the Coronary Tree (PROSPECT) study, we evaluated 552 LMCAs in 552 patients. External elastic membrane cross-sectional areas (CSAs) increased in proportion to the increase in plaque and media CSAs (r=0.61, P40% plaque burden), there was an inverse relationship between lumen CSA and plaque burden (r=-0.57, PPROSPECT study patients. In addition, the present study suggested that plaque phenotype worsened with increasing LMCA plaque growth.

  14. Intravascular Large B-Cell Lymphoma Presenting as Interstitial Lung Disease

    Directory of Open Access Journals (Sweden)

    Elham Vali Khojeini

    2014-01-01

    Full Text Available Intravascular large B-cell lymphoma (IVLBL is a rare subtype of diffuse large B-cell lymphoma that resides in the lumen of blood vessels. Patients typically present with nonspecific findings, particularly bizarre neurologic symptoms, fever, and skin lesions. A woman presented with shortness of breath and a chest CT scan showed diffuse interstitial thickening and ground glass opacities suggestive of an interstitial lung disease. On physical exam she was noted to have splenomegaly. The patient died and at autopsy was found to have an IVLBL in her lungs as well as nearly all her organs that were sampled. Although rare, IVLBL should be included in the differential diagnosis of interstitial lung disease and this case underscores the importance of the continuation of autopsies.

  15. Design and implementation of an intravascular brachytherapy installation in cardiology

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J.M.; Sabate, M.; Galvan, Y.C.

    2001-01-01

    Intravascular Brachytherapy (IVB) is a very promising technique for reducing restenosis rates. However, neither the exact absolute dose needed nor the optimal spatial and temporal distribution of dose inside the vessel wall for a successful treatment, nor the physical dosimetry of the various radioactive sources and devices for dose delivery, are well known. In this paper, an overview will be given of the design strategy, the dosimetric and radiation protection-related problems that we have met during the implementation of this technique at San Carlos hospital, adopted or foreseen solutions, and future research fields that we intend to carry out in order to reduce uncertainties and to achieve a deeper knowledge of the parameters that have an influence on the treatment. (author)

  16. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  17. Knee ultrasound from research to real practice: a systematic literature review of adult knee ultrasound assessment feasibility studies.

    Science.gov (United States)

    Peltea, Alexandra; Berghea, Florian; Gudu, Tania; Ionescu, Ruxandra

    2016-12-05

    To identify and analyse existing data regarding knee ultrasound (US) feasibility in clinical practice. Material and methods: A systematic literature review was performed using the terms: ("knee") AND ("ultrasound" OR "ultrasonography") AND ("feasibility" OR "pilot" OR "proof of concept"). Feasibility studies regarding knee US or US aided maneuver involving knee joint, published during 2005-2015, were selected and evaluated against a complex framework constructed around mandatory key areas for feasibility studies: acceptability, demand, implementation, practicality, adaptation, integration and expansion. One hundred and fifty-nine publications were identified, of which 9 were included in the final analysis: 6 dealt with the development and implementation of novel US scores, while the rest focused on implementing MSUS in clinical practice, evaluating the usefulness of articular cartilage US assessment and the feasibility of sonography for intra-articular knee injections, respectively. Six studies quantified feasibility as time spent for the evaluation, with only two addressing areassuch as acceptability, implementation and practicality, although none of these systematically assessed all feasibility domains. Knee US feasibility is still poorly addressed; the time required for US assessment is the main area addressed. This information gap should be properly addressed in future works, in order to ensure the right place for this technique.

  18. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  19. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  20. Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

    International Nuclear Information System (INIS)

    Tanimoto, Daigo; Ito, Katsuyoshi; Yamamoto, Akira; Sone, Teruki; Kobatake, Makito; Tamada, Tsutomu; Umetani, Keiji

    2010-01-01

    This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 μm) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10 7 μm 3 ) were significantly smaller (p 7 μm 3 ) and SAP-MS (S) (5.85 x 10 7 μm 3 ). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10 7 μm 3 vs. 1.24 x 10 7 μm 3 ; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

  1. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  2. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  3. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  4. Impact of a 2-Day Critical Care Ultrasound Course during Fellowship Training: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Vi Am Dinh

    2015-01-01

    Full Text Available Objectives. Despite the increasing utilization of point-of-care critical care ultrasonography (CCUS, standards establishing competency for its use are lacking. The purpose of this study was to evaluate the effectiveness of a 2-day CCUS course implementation on ultrasound-naïve critical care medicine (CCM fellows. Methods. Prospective evaluation of the impact of a two-day CCUS course on eight CCM fellows’ attitudes, proficiency, and use of CCUS. Ultrasound competency on multiple organ systems was assessed including abdominal, pulmonary, vascular, and cardiac systems. Subjects served as self-controls and were assessed just prior to, within 1 week after, and 3 months after the course. Results. There was a significant improvement in CCM fellows’ written test scores, image acquisition ability, and pathologic image interpretation 1 week after the course and it was retained 3 months after the course. Fellows also had self-reported increased confidence and usage of CCUS applications after the course. Conclusions. Implementation of a 2-day critical care ultrasound course covering general CCUS and basic critical care echocardiography using a combination of didactics, live models, and ultrasound simulators is effective in improving critical care fellows’ proficiency and confidence with ultrasound use in both the short- and long-term settings.

  5. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  6. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  7. A study of pipe flow rate measurement using air-coupled ultrasound

    International Nuclear Information System (INIS)

    Tsukada, Keisuke; Tsuzuki, Nobuyoshi; Kikura, Hiroshige

    2013-01-01

    A non-contact flow meter employing air-coupled ultrasound is developed in this research. Ultrasonic flow meter is applied to the higher accuracy flow rate measurement, compared with pressure difference flow meter. However, ultrasonic flow meter has difficulty to measure in severe conditions such as in the condition of high temperature, high pressure condition, and radioactive materials in fluid. Especially, in high temperature condition, piezoelectric device in ultrasonic sensors lose the piezoelectricity, and it becomes difficult to transmit or detect ultrasound. Thus, in this research, ultrasonic sensors are fixed in the air. Ultrasonic sensors transmit and detect ultrasound through air, and measure the flow rate in the pipe. However, most of ultrasound is refracted and reflected at the boundaries between air and the pipe. And detected signals are weak. To increase the signal level, we developed focusing ultrasonic sensors that was optimized for the pipe flow measurement. And employing these focusing sensors the flow rate measurement has been done in order to evaluate the air-coupled ultrasonic flow meter by the ultrasonic beam focusing technique. (author)

  8. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  9. Auscultation versus Point-of-care Ultrasound to Determine Endotracheal versus Bronchial Intubation: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Ramsingh, Davinder; Frank, Ethan; Haughton, Robert; Schilling, John; Gimenez, Kimberly M; Banh, Esther; Rinehart, Joseph; Cannesson, Maxime

    2016-05-01

    Unrecognized malposition of the endotracheal tube (ETT) can lead to severe complications in patients under general anesthesia. The focus of this double-blinded randomized study was to assess the accuracy of point-of-care ultrasound in verifying the correct position of the ETT and to compare it with the accuracy of auscultation. Forty-two adult patients requiring general anesthesia with ETT were consented. Patients were randomized to right main bronchus, left main bronchus, or tracheal intubation. After randomization, the ETT was placed via fiber-optic visualization. Next, the location of the ETT was assessed using auscultation by a separate blinded anesthesiologist, followed by an ultrasound performed by a third blinded anesthesiologist. Ultrasound examination included assessment of tracheal dilation via cuff inflation with air and evaluation of pleural lung sliding. Statistical analysis included sensitivity, specificity, positive predictive value, negative predictive value, and interobserver agreement for the ultrasound examination (95% CI). In differentiating tracheal versus bronchial intubations, auscultation showed a sensitivity of 66% (0.39 to 0.87) and a specificity of 59% (0.39 to 0.77), whereas ultrasound showed a sensitivity of 93% (0.66 to 0.99) and specificity of 96% (0.79 to 1). Identification of tracheal versus bronchial intubation was 62% (26 of 42) in the auscultation group and 95% (40 of 42) in the ultrasound group (P = 0.0005) (CI for difference, 0.15 to 0.52), and the McNemar comparison showed statistically significant improvement with ultrasound (P auscultation in determining the location of ETT.

  10. Intravascular large B-cell lymphoma of the kidney: A case report

    Directory of Open Access Journals (Sweden)

    Jia Nan

    2011-09-01

    Full Text Available Abstract We report a 41-year-old Chinese woman with intravascular large B-cell lymphoma diagnosed by percutaneous renal biopsy. The patient was admitted to Nanfang Hospital of Southern Medical University, Guangzhou, China with complaints of high spiking fever for a month and bilateral lower limb fatigue with difficulty ambulating for the past 5 months. She had renal dysfunction with a total urinary protein of 5.61 g/dL (56.1 g/L, serum albumin of 2.89 g/dL (28.9 g/L, urea nitrogen of 2.24 mg/dL (1.6 mmol/L, and serum creatinine of 0.54 mg/dL (48 μmol/L. Bone marrow biopsy revealed myeloproliferative disorder without abnormal myeloid or lymphocytic proliferation. Positron Emission Tomography-Computed Tomography (PET-CT showed marked bilateral swelling and enlargement of the renal parenchyma with splenic enlargement and involvement of multiple vertebrae. Percutaneous renal biopsy showed island-like accumulations of medium to large lymphoid cells in many areas of the interstitium, with round vesicular nuclei containing distinct basophilic nucleoli. Immunohistochemical analysis together with other supportive investigation confirmed the diagnosis of intravascular large B-cell lymphoma. Ten days later, she was started on chemotherapy with CHOP (cyclophosphamide, doxorubicin, leurocristime and prednisone for a week. Palliative radiotherapy DT 40Gy/20F with other supportive treatment was provided for metastatic foci in the medullary cavity of the sternum, T1-T7. The patient regained muscle strength in both lower limbs and was able to walk again after three weeks. The patient was discharged after hepatic and renal function and proteinuria values had returned to normal. Follow-up data shows the patient to be alive nine months after discharge.

  11. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  12. Musculoskeletal ultrasound and other imaging modalities in rheumatoid arthritis.

    Science.gov (United States)

    Ohrndorf, Sarah; Werner, Stephanie G; Finzel, Stephanie; Backhaus, Marina

    2013-05-01

    This review refers to the use of musculoskeletal ultrasound in patients with rheumatoid arthritis (RA) both in clinical practice and research. Furthermore, other novel sensitive imaging modalities (high resolution peripheral quantitative computed tomography and fluorescence optical imaging) are introduced in this article. Recently published ultrasound studies presented power Doppler activity by ultrasound highly predictive for later radiographic erosions in patients with RA. Another study presented synovitis detected by ultrasound being predictive of subsequent structural radiographic destruction irrespective of the ultrasound modality (grayscale ultrasound/power Doppler ultrasound). Further studies are currently under way which prove ultrasound findings as imaging biomarkers in the destructive process of RA. Other introduced novel imaging modalities are in the validation process to prove their impact and significance in inflammatory joint diseases. The introduced imaging modalities show different sensitivities and specificities as well as strength and weakness belonging to the assessment of inflammation, differentiation of the involved structures and radiological progression. The review tries to give an answer regarding how to best integrate them into daily clinical practice with the aim to improve the diagnostic algorithms, the daily patient care and, furthermore, the disease's outcome.

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  15. Experimental study on ablating goat liver tissue with ultrasound imaging guided percutaneous irreversible electroporation

    Directory of Open Access Journals (Sweden)

    Ying LIU

    2011-03-01

    Full Text Available Objective To investigate the proper method of percutaneous irreversible electroporation(IRE to ablate goat liver tissue under ultrasonic guidance,and observe the features of ultrasound imaging and histological changes.Methods The pulse electric fields(PEFs with permanent duration(100 μs,frequency(1Hz,voltage(2000V and pulses(120 pieces were applied to the electrodes,and the electrodes were placed into goats’ liver under ultrasound guidance through the animal skin to the target area.The treated area was observed by real-time ultrasound scanning,and the histopathological changes were assessed by hematoxylin and eosin(HE staining under light microscope at the time of 0h and 24h after IRE ablation.The circumscribed ablated area was compared with that of finite element modeling(FEM calculation method.Results Ultrasound imaging guidance was accurate in focusing on the target area.Imaging captured by the ultrasound after IRE procedure was quite different from that of the normal liver imaging.Complete hepatic cell death with a sharp demarcation between the ablated zone and the non-ablated zone was well visualized 24 hours after the procedure.Necrospy-based measurement demonstrated a high consistence with FEM-anticipated ablation zones.Conclusion With real-time monitoring by ultrasonography and well-controlled ablation of the target tissue,percutaneous IRE can provide a novel and unique ablative method for cancer treatment.The present paper provides a fundamental experimental work for future studies on clinical application of IRE.

  16. Th1 differentiation drives the accumulation of intravascular, non-protective CD4 T cells during tuberculosis

    Science.gov (United States)

    Sallin, Michelle A.; Sakai, Shunsuke; Kauffman, Keith D.; Young, Howard A.; Zhu, Jinfang; Barber, Daniel L.

    2017-01-01

    SUMMARY Recent data indicate that the differentiation state of Th1 cells determines their protective capacity against tuberculosis. Therefore, we examined the role of Th1 polarizing factors in the generation of protective and non-protective subsets of Mtb-specific Th1 cells. We find IL-12/23p40 promotes Th1 cell expansion and maturation beyond the CD73+CXCR3+T-betdim stage, and T-bet prevents deviation of Th1 cells into Th17 cells. Nevertheless, IL-12/23p40 and T-bet are also essential for the production of a prominent subset of intravascular CX3CR1+KLRG1+ Th1 cells that persists poorly and can neither migrate into the lung parenchyma nor control Mtb growth. Furthermore, T-bet suppresses development of CD69+CD103+ tissue resident phenotype effectors in lung. In contrast, Th1 cell-derived IFNγ inhibits the accumulation of intravascular CX3CR1+KLRG1+ Th1 cells. Thus, although IL-12 and T-bet are essential host survival factors, they simultaneously oppose lung CD4 T cell responses at several levels, demonstrating the dual nature of Th1 polarization in tuberculosis. PMID:28355562

  17. Monitoring Progression of Amyotrophic Lateral Sclerosis Using Ultrasound Morpho-Textural Muscle Biomarkers: A Pilot Study.

    Science.gov (United States)

    Martínez-Payá, Jacinto J; Ríos-Díaz, José; Medina-Mirapeix, Francesc; Vázquez-Costa, Juan F; Del Baño-Aledo, María Elena

    2018-01-01

    The need is increasing for progression biomarkers that allow the loss of motor neurons in amyotrophic lateral sclerosis (ALS) to be monitored in clinical trials. In this prospective longitudinal study, muscle thickness, echointensity, echovariation and gray level co-occurrence matrix textural features are examined as possible progression ultrasound biomarkers in ALS patients during a 5-mo follow-up period. We subjected 13 patients to 3 measurements for 20 wk. They showed a significant loss of muscle, an evident tendency to loss of thickness and increased echointensity and echovariation. In regard to textural parameters, muscle heterogeneity tended to increase as a result of the neoformation of non-contractile tissue through denervation. Considering some limitations of the study, the quantitative muscle ultrasound biomarkers evaluated showed a promising ability to monitor patients affected by ALS. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  7. Multiparametric ultrasound in the detection of prostate cancer: a systematic review.

    Science.gov (United States)

    Postema, Arnoud; Mischi, Massimo; de la Rosette, Jean; Wijkstra, Hessel

    2015-11-01

    To investigate the advances and clinical results of the different ultrasound modalities and the progress in combining them into multiparametric UltraSound (mpUS). A systematic literature search on mpUS and the different ultrasound modalities included: greyscale ultrasound, computerized transrectal ultrasound, Doppler and power Doppler techniques, dynamic contrast-enhanced ultrasound and (shear wave) elastography. Limited research available on combining ultrasound modalities has presented improvement in diagnostic performance. The data of two studies suggest that even adding a lower performing ultrasound modality to a better performing modality using crude methods can already improve the sensitivity by 13-51 %. The different modalities detect different tumours. No study has tried to combine ultrasound modalities employing a system similar to the PIRADS system used for mpMRI or more advanced classifying algorithms. Available evidence confirms that combining different ultrasound modalities significantly improves diagnostic performance.

  8. Diagnostic Ultrasound in Colorectal Cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael

    2014-01-01

    SUMMARYBackground and purpose Colorectal cancer is a common disease in Denmark with considerable morbidity and mortality. Although survival in recent years has improved, Denmark still has the lowest 5-year survival compared to the other Nordic countries. The treatment of patients depends on local...... the potential to contribute to the staging of colorectal cancer. The purpose of these studies was to determine the usefulness of ultrasound diagnostics in patients with colorectal cancer.The purpose of the TRUS studies was to compare staging of rectal carcinomas using digital rectal exploration...... of 295 patients with primary colorectal cancer we found a sensitivity of preoperative ultrasound, surgical exploration, and intraoperative ultrasound of 70%, 84%, and 97%, respectively, based on a patient-by-patient comparison (p

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  13. STUDY OF ULTRASOUND FINDING IN DENGUE FEVER

    Directory of Open Access Journals (Sweden)

    Sunita Bajaj

    2016-10-01

    Full Text Available BACKGROUND Dengue fever (DF is a viral haemorrhagic fever causing severe morbidity and mortality in affected patients. The aim of the study is to describe the role of ultrasonography (USG in the assessment of patients with Dengue fever, and its complications and to prove ultrasound is useful in the diagnosis during an epidemic. MATERIALS AND METHODS It is a prospective study was conducted in 2016 comprising of 178 patients who were serologically positive for dengue, radiological investigations were conducted in all cases. RESULTS Out of 178 patients Males (N=117 are more effected subjects in the study. female: Male ratio is 1:2. Hepatomegaly 74.1% which is most common findings in study, 113 (63.4% had GB wall thickening 98 had ascites (55%, 32 had pleural effusion (17.9%. most commonly seen in the age group of 20-39 years. Hepatomegaly was the most common finding noted in 67 patients (37.6%, followed by GB wall thickening in 65 patients (36.1%. Hepatomegaly was more common in 0-19 is 56 patients with 31.4% years age group Ascites in >40 years age group (16.8%. Hepatomegaly was seen in most of the patients whose platelet count was <40,000. (94.7%. GB wall thickening (88.5% common findings seen in patients whose platelet count was <40,000. In patients with platelet count of 40,000-80,000, Ascites is most common finding (87.5%, followed by Splenomegaly (60.7%. In patients whose platelet count was 80,000-150,000, Ascites (50% was more common than Splenomegaly (45.8%. In three patients with platelet count more than 150,000, no sonological abnormality was detected. CONCLUSIONS Ultrasound findings of hepatic changes, GB wall oedema, splenomegaly, ascites and pleural effusion in patients presenting with signs and symptoms of Dengue fever during an epidemic are diagnostic. Contributing in the differential diagnosis with other causes of febrile disease.

  14. Application of Gafchromic registered film in the dosimetry of an intravascular brachytherapy source

    International Nuclear Information System (INIS)

    Song Haijun; Roa, D. Eduardo; Yue Ning; D'Errico, Francesco; Chen Zhe; Nath, Ravinder

    2006-01-01

    The methodology of brachytherapy source dosimetry with Gafchromic registered MD 55-2 film (ISP Technologies, Inc.) is examined with an emphasis on the nonlinearity of the optical density-dose relation within the dynamic dose range, the radial distance-dependent measurement uncertainty, and the format of data presentation. The specific source chosen for this study was a Checkmate trade mark sign (Cordis Corporation) intravascular brachytherapy system. The two-dimensional dose distribution around the source was characterized by a comprehensive analysis of measurement uncertainties. A comparative analysis of the dosimetric data from the vendor and from the scientific literature showed a substantial consistency of the information available for the Checkmate trade mark sign source. Our two-dimensional dosimetric data for the Checkmate trade mark sign source trains is presented in the form of measured along and away dose tables

  15. MRI evaluation and follow-up of bone necrosis after meningococcal infection and disseminated intravascular coagulation

    International Nuclear Information System (INIS)

    Damry, N.; Schurmans, T.; Perlmutter, N.

    1993-01-01

    Disseminated intravascular coagulation (DIC) is a serious complication of meningococcal septicaemia. It often results in infarction of various tissues namely the skin, adrenal glands, kidneys, brain and, much less commonly, bones. We describe a patient who presented bone lesions after meningococcal septicaemia. In addition to plain radiography and scintigraphy the lesions were evaluated with MRI and have proved to be extensive and still progressive, approxximately 18 months after the onset of the disease. (orig.)

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  18. Virtual Ultrasound Guidance for Inexperienced Operators

    Science.gov (United States)

    Caine, Timothy; Martin, David

    2012-01-01

    Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with

  19. In-Vivo Assessment of Coronary Atherosclerosis

    NARCIS (Netherlands)

    G.A. Rodriguez-Granillo

    2006-01-01

    textabstractIntravascular ultrasound (IVUS) has emerged as a highly accurate tool for the serial assessment of the natural history of coronary atherosclerosis and to evaluate the effect of different conventional and emerging drug therapies on the progression of atherosclerosis. The

  20. Usefulness of Coronary Atheroma Burden to Predict Cardiovascular Events in Patients Presenting With Acute Coronary Syndromes (from the PROSPECT Study).

    Science.gov (United States)

    Shan, Peiren; Mintz, Gary S; McPherson, John A; De Bruyne, Bernard; Farhat, Naim Z; Marso, Steven P; Serruys, Patrick W; Stone, Gregg W; Maehara, Akiko

    2015-12-01

    We investigated the relation between overall atheroma burden and clinical events in the Providing Regional Observations to Study Predictors of Events in the Coronary Tree (PROSPECT) study. In PROSPECT, 660 patients (3,229 nonculprit lesions with a plaque burden ≥ 40% and complete intravascular ultrasound data) were divided into tertiles according to baseline percent atheroma volume (PAV: total plaque/vessel volume). Patients were followed for 3.4 years (median); major adverse cardiac events (MACE: death from cardiac causes, cardiac arrest, myocardial infarction, or rehospitalization because of unstable or progressive angina) were adjudicated to either culprit or nonculprit lesions. Compared with patients in low or intermediate PAV tertiles, patients in the high PAV tertile had the greatest prevalence of plaque rupture and radiofrequency thin-cap fibroatheroma (VH-TCFA) and the highest percentage of necrotic core volume; they were also more likely to have high-risk lesion characteristics: ≥ 1 lesion with minimal luminal area ≤ 4 mm(2), plaque burden >70%, and/or VH-TCFA. Three-year cumulative nonculprit lesion-related MACE was greater in the intermediate and high tertiles than in the low tertile (6.3% vs 14.7% vs 15.1%, low vs intermediate vs high tertiles, p = 0.009). On Cox multivariable analysis, insulin-dependent diabetes (hazard ratio [HR] 3.98, p = 0.002), PAV (HR 1.06, p = 0.03), and the presence of ≥1 VH-TCFA (HR 1.80, p = 0.02) were independent predictors of nonculprit MACE. In conclusion, increasing baseline overall atheroma burden was associated with more advanced, complex, and vulnerable intravascular ultrasound lesion morphology and independently predicted nonculprit lesion-related MACE in patients with acute coronary syndromes after successful culprit lesion intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  2. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  3. [Role of ultrasound in elective abortions].

    Science.gov (United States)

    Wylomanski, S; Winer, N

    2016-12-01

    Ultrasound plays a fundamental role in the management of elective abortions. Although it can improve the quality of post-abortion care, it must not be an obstacle to abortion access. We thus studied the role of ultrasound in pregnancy dating and possible alternatives and analyzed the literature to determine the role of ultrasound in post-abortion follow-up. During an ultrasound scan, the date of conception is estimated by measurement of the crown-rump length (CRL), defined by Robinson, or of the biparietal diameter (BPD), as defined by the French Center for Fetal Ultrasound (CFEF) after 11 weeks of gestation (Robinson and CFEF curves) (grade B). Updated curves have been developed in the INTERGROWTH study. In the context of abortion, the literature recommends the application of a safety margin of 5 days, especially when the CRL and/or BPD measurement indicates a term close to 14 weeks (that is equal or below 80 and 27mm, respectively) (best practice agreement). Accordingly, with the ultrasound measurement reliable to±5 days when its performance meets the relevant criteria, an abortion can take place when the CRL measurement is less than 90mm or the BPD less than 30mm (INTERGROWTH curves) (best practice agreement). While a dating ultrasound should be encouraged, its absence is not an obstacle to scheduling an abortion for women who report that they know the date of their last menstrual period and/or of the at-risk sexual relations and for whom a clinical examination by a healthcare professional is possible (best practice agreement). In cases of intrauterine pregnancy of uncertain viability or of a pregnancy of unknown location, without any particular symptoms, the patient must be able to have a transvaginal ultrasound to increase the precision of the diagnosis (grade B). Various reviews of the literature on post-abortion follow-up indicate that the routine use of ultrasound during instrumental abortions should be avoided (best practice agreement). If it becomes

  4. Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.

    Science.gov (United States)

    Chen, Gui Qiu; Chen, Yu Hao; Yi, Liang; Yin, Jin; Gao, Qiong; Song, Jiang Nan; Li, Shi Kang; Chen, Pei Hou; Guo, Gui Ping

    2018-02-01

    We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  5. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    Science.gov (United States)

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  6. Study of cell killing effect on S180 by ultrasound activating protoporphyrin IX.

    Science.gov (United States)

    Wang, Xiao Bing; Liu, Quan Hong; Wang, Pan; Tang, Wei; Hao, Qiao

    2008-04-01

    The present study was initiated to investigate the potential biological mechanism of cell killing effect on isolate sarcoma 180 (S180) cells induced by ultrasound activating protoporphyrin IX (PPIX). S180 cells were exposed to ultrasound for 30s duration, at a frequency of 2.2 MHz and an acoustic power of 3 W/cm(2) in the presence of 120 microM PPIX. The viability of cells was evaluated using trypan blue staining. The generation of oxygen free radicals in cell suspensions was detected immediately after treatment using a reactive oxygen detection kit. A copper reagent colorimetry method was used to measure the level of FFAs released into cell suspensions by the process of cell damage induced by ultrasound and PPIX treatment. Oxidative stress was assessed by measuring the activities of key antioxidant enzymes (i.e., SOD, CAT, GSH-PX) in S180 tumor cells. Treatment with ultrasound and PPIX together increased the cell damage rate to 50.91%, while treatment with ultrasound alone gave a cell damage rate to 24.24%, and PPIX alone kept this rate unchanged. Colorimetry and enzymatic chemical methods showed that the level of FFAs in cell suspension increased significantly after the treatment, while the activity of all the above enzymes decreased in tumor cells at different levels, and were associated with the generation of oxygen free radicals in cell suspension after treatment. The results indicate that oxygen free radicals may play an important role in improving the membrane lipid peroxidation, degrading membrane phospholipids to release FFAs, and decreasing the activities of the key antioxidant enzymes in cells. This biological mechanism might be involved in mediating the effects on S180 cells and resulting in the cell damage seen with SDT.

  7. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Portable bladder ultrasound: an evidence-based analysis.

    Science.gov (United States)

    2006-01-01

    retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of

  9. Acute kidney injury and disseminated intravascular coagulation due to mercuric chloride poisoning

    Directory of Open Access Journals (Sweden)

    J Dhanapriya

    2016-01-01

    Full Text Available Mercury is a toxic heavy metal and occurs in organic and inorganic forms. Inorganic mercury includes elemental mercury and mercury salts. Mercury salts are usually white powder or crystals, and widely used in indigenous medicines and folk remedies in Asia. Inorganic mercury poisoning causes acute kidney injury (AKI and gastrointestinal manifestations and can be life-threatening. We describe a case with unknown substance poisoning who developed AKI and disseminated intravascular coagulation (DIC. Renal biopsy showed acute tubular necrosis. Later, the consumed substance was proven to be mercuric chloride. His renal failure improved over time, and his creatinine normalized after 2 months.

  10. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  11. Dynamic magnetic resonance angiography of the arteries of the hand. A comparison between an extracellular and an intravascular contrast agent

    International Nuclear Information System (INIS)

    Reisinger, Clemens; Gluecker, Thomas; Jacob, Augustinus Ludwig; Bongartz, Georg; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to compare the image quality of the intravascular contrast agent gadofosveset with the extracellular contrast agent gadoterate meglumine in time-resolved three-dimensional magnetic resonance (MR) angiography of the human arteries of the hand. The value of cuff compression technique for suppression of venous enhancement for both contrast agents was also investigated. Three-dimensional MR angiograms of both hands of 11 healthy volunteers were acquired for each contrast agent at 1.5-T, while subsystolic cuff compression was applied at one side. Quantitative and qualitative evaluation were performed and analyzed with Student's t-test. Visualization of vessels was superior in the images acquired with gadofosveset, especially in the late phases. Quantitative and qualitative evaluation showed significantly higher values for gadofosveset. The cuff compression at the lower arm proved to be an effective method to enhance arterial vessels. In conclusion the blood pool agent gadofosveset is superior for the dynamic imaging of the vessels of the hand when compared with the extracellular contrast agent gadoterate meglumine. To fully utilize the advantages of intravascular contrast agents, venous overlay has to be delayed or reduced, which can be achieved effectively by subsystolic lower arm cuff compression. (orig.)

  12. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  13. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjunction: Comparison of radiographic, ultrasound and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Faruch Bilfeld, Marie; Lapegue, Franck; Chiavassa Gandois, Helene; Bayol, Marie Aurelie; Sans, Nicolas [CHU Toulouse-Purpan, Service de Radiologie, Toulouse Cedex 9 (France); Bonnevialle, Nicolas [CHU Toulouse-Purpan, Service d' Orthopedie, Toulouse Cedex 9 (France)

    2017-02-15

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p < 0.0001). Ultrasound detected coracoclavicular ligament injuries with a sensitivity of 88.9 %, specificity of 90.0 %, positive predictive value of 92.3 % and negative predictive value of 85.7 %. The agreement between the ultrasound and radiography findings was poor, with a correlation coefficient of 0.69 (95 % CI: 0.51-0.82; p < 0.0001). Ultrasound is an effective examination for the diagnostic work-up of lesions of the coracoclavicular ligaments in the acute phase of an acromioclavicular injury. (orig.)

  14. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjunction: Comparison of radiographic, ultrasound and MRI findings

    International Nuclear Information System (INIS)

    Faruch Bilfeld, Marie; Lapegue, Franck; Chiavassa Gandois, Helene; Bayol, Marie Aurelie; Sans, Nicolas; Bonnevialle, Nicolas

    2017-01-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p < 0.0001). Ultrasound detected coracoclavicular ligament injuries with a sensitivity of 88.9 %, specificity of 90.0 %, positive predictive value of 92.3 % and negative predictive value of 85.7 %. The agreement between the ultrasound and radiography findings was poor, with a correlation coefficient of 0.69 (95 % CI: 0.51-0.82; p < 0.0001). Ultrasound is an effective examination for the diagnostic work-up of lesions of the coracoclavicular ligaments in the acute phase of an acromioclavicular injury. (orig.)

  15. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  16. Ultrasound Mediated Microbubbles Destruction Augmented Sonolysis: An In Vitro and In Vivo Study.

    Science.gov (United States)

    Cui, Hai; Zhu, Qiong; Gao, Yunhua; Xia, Hongmei; Tan, Kaibin; He, Ying; Liu, Zheng; Xu, Yali

    2017-01-01

    This study was aimed at exploring ultrasound mediated microbubbles destruction (UMMD) assisted sonolysis in both the in vitro and in vivo clots. Therapeutic ultrasound (TUS) and lipid microbubbles (MBs) were used in whole blood clots and divided into the control, TUS group, and TUS + MB group. Thrombolytic rates and microscopy were performed. Color Doppler flow imaging (CDFI) and angiography were performed to evaluate the recanalization rates and flow scores in femoral arterial thrombus (FAT) in rabbits. FAT were dyed with H&E. The average thrombolytic ratios of TUS + MB group were significantly higher than those of TUS group and the control group (both P cavitation via UMMD.

  17. Detection of the Single-Session Complete Ablation Rate by Contrast-Enhanced Ultrasound during Ultrasound-Guided Laser Ablation for Benign Thyroid Nodules: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Shuhua Ma

    2016-01-01

    Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.

  18. The clinical study of 2D and power doppler ultrasound in esophagus varix

    International Nuclear Information System (INIS)

    Li Qiang; Zhou Liang; Zhang Yucheng; Yang Minghua; Ruan Fenglian; Lu Haixia; Li Yue

    2008-01-01

    Objective: To study the application of 2D and Power Doppler Ultrasound in diagnosing the abdominal esophageal varicose veins. Methods: 65 patients under suspicion with chronic hepatitis and cirrhosis for esophageal varicose at esophagus in abdomen section were examined by 2D and Power Doppler Ultrasound.Among them, 35 patients suffered from esophageal varicose veins proved by gastroscopy and the rest did not. Results: On the power doppler imaging map, colored blood stream signals were showed in varicose veins while without signals in non-varicose veins.The diagnostic sensitivity and specificity were 91.4% and 100% respectively. On the two-dimensional image chart, non-echoes were represented in varicose veins. The anteroposterior diameter, right-left diameter, as well as the thickness of esophagus wall were larger in patients with varicose veins than those in non varicose veins cases (P<0.01). Conclusion: 2D combined with Power Doppler Ultrasound was of non-invasive, safe, sensitive and high specificity, which is a valuable and practical tool in diagnosing the esophageal varicose veins. (authors)

  19. A Micromotor Catheter for Intravascular Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Tianshi Wang

    2015-03-01

    Full Text Available We have developed a new form of intravascular optical coherence tomography (IV-OCT that allows the extremely fast acquisition of high-resolution images of the coronary arteries. This process leads to much better image quality by eliminating cardiac motion artefacts and undersampling. It relies on a catheter that incorporates a synchronous micromotor with a diameter of 1.0 mm and a rotational speed of up to 5600 revolutions per second, enabling an IV-OCT frame rate of 5.6 kHz. This speed is matched by a wavelength-swept laser that generates up to 2.8 million image lines per second. With this setup, our team achieved IV-OCT imaging of up to 5600 frames per second (fps in vitro and 4000 fps in vivo, deployed at a 100 mm·s−1 pullback velocity. The imaging session is triggered by the electrocardiogram of the subject, and can scan a coronary artery in the phase of the heartbeat where the heart is at rest, providing a name for this new technology: the “Heartbeat OCT.”

  20. Prenatal ultrasound and postmortem histologic evaluation of tooth germs: an observational, transversal study.

    Science.gov (United States)

    Seabra, Mariana; Felino, António; Nogueira, Rosete; Valente, Francisco; Braga, Ana Cristina; Vaz, Paula

    2015-05-12

    Hypodontia is the most frequent developmental anomaly of the orofacial complex, and its detection in prenatal ultrasound may indicate the presence of congenital malformations, genetic syndromes and chromosomal abnormalities. To date, only a few studies have evaluated the histological relationship of human tooth germs identified by two-dimensional (2D) ultrasonography. In order to analyze whether two-dimensional ultrasonography of tooth germs may be successfully used for identifying genetic syndromes, prenatal ultrasound images of fetal tooth germs obtained from a Portuguese population sample were compared with histological images obtained from fetal autopsies. Observational, descriptive, transversal study. The study protocol followed the ethical principles outlined by the Helsinki Declaration and was approved by the Ethics Committee of the School of Dental Medicine, University of Porto (FMDUP, Porto, Portugal) and of the Centro Hospitalar de Vila Nova de Gaia/Espinho (CHVNG/EPE, Porto, Portugal) as well as by the CGC Genetics Embryofetal Pathology Laboratory. Eighty-five fetuses examined by prenatal ultrasound screening from May 2011 to August 2012 had an indication for autopsy following spontaneous fetal death or medical termination of pregnancy. Of the 85 fetuses, 37 (43.5%) were randomly selected for tooth germ evaluation by routine histopathological analysis. Fetuses who were up to 30 weeks of gestation, and whose histological pieces were not representative of all maxillary tooth germs was excluded. Twenty four fetus between the 13(th) and 30(th) weeks of gestation fulfilled the parameters to autopsy. Twenty four fetuses were submitted to histological evaluation and were determined the exact number, morphology, and mineralization of their tooth germs. All tooth germs were identifiable with ultrasonography as early as the 13(th) week of gestation. Of the fetuses autopsied, 41.7% had hypodontia (29.1% maxillary hypodontia and 20.9% mandibular hypodontia). This

  1. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  2. High definition ultrasound imaging for battlefield medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, K.S.; Morimoto, A.K.; Kozlowski, D.M.; Krumm, J.C.; Dickey, F.M. [Sandia National Labs., Albuquerque, NM (United States); Rogers, B; Walsh, N. [Texas Univ. Health Science Center, San Antonio, TX (United States)

    1996-06-23

    A team has developed an improved resolution ultrasound system for low cost diagnostics. This paper describes the development of an ultrasound based imaging system capable of generating 3D images showing surface and subsurface tissue and bone structures. We include results of a comparative study between images obtained from X-Ray Computed Tomography (CT) and ultrasound. We found that the quality of ultrasound images compares favorably with those from CT. Volumetric and surface data extracted from these images were within 7% of the range between ultrasound and CT scans. We also include images of porcine abdominal scans from two different sets of animal trials.

  3. Efficacy of alfaxalone for intravascular anesthesia and euthanasia in blue crabs (Callinectes sapidus).

    Science.gov (United States)

    Minter, Larry J; Harms, Craig A; Archibald, Kate E; Broadhurst, Heather; Bailey, Kate M; Christiansen, Emily F; Lewbart, Gregory A; Posner, Lysa P

    2013-09-01

    The objective of this study was to characterize the behavioral effects and changes in heart rate of four doses of alfaxalone delivered by intravascular injection to blue crabs (Callinectes sapidus). Thirty (male, n = 27; female, n = 3) blue crabs were randomly assigned to one of four treatment groups of alfaxalone: eight animals were assigned to each of the 5-, 10-, and 15-mg/kg treatment groups, and the remaining six animals were assigned to the 100-mg/kg group. Times for anesthetic induction and recovery periods were recorded. Righting reflex, defensive posturing, and heart rate were evaluated before, during, and after the anesthetic trial. Anesthesia was induced in all 14 animals consolidated into the high-dosage group (15 mg/kg [n = 8] and 100 mg/kg [n = 6]), which was significantly greater than 8 of 16 animals in the low-dosage group (5 mg/kg [n = 2] and 10 mg/kg [n = 6]). Median anesthesia induction time for all crabs was 0.4 min, with no significant difference in induction time between groups observed. Median recovery time was 9.4 min (n = 2), 6.1 min (n = 5), 11.3 min (n = 8), and 66.1 min (n = 5) for the 5-, 10-, 15-, and 100-mg/kg groups, respectively. Recovery times were significantly longer for crabs exposed to an induction dose of 100 mg/kg compared with the 10- and 15-mg/kg induction doses. A significant decrease in the median heart rate was observed between the baseline value and that observed at both induction and 5 min postinjection in the 100-mg/kg dose trial. Two mortalities were observed during the anesthesia trials (n = 1, 10 mg/kg; n = 1, 100 mg/kg), both associated with the autotomization of limbs. In summary, the intravascular administration of alfaxalone at 15 mg/kg provided rapid and reliable sedation, whereas alfaxalone administered at 100 mg/kg produced rapid and long lasting anesthesia.

  4. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  5. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  7. Trans-abdominal ultrasound evaluation of high-intensity focused ultrasound treatment of uterine leiomyoma

    International Nuclear Information System (INIS)

    Miao Wei; Huang Jin; Wang Junhua; Wang Yuling

    2010-01-01

    Objective: To determine the value of dynamic trans-abdominal ultrasound after high-intensity focused ultrasound (HIFU) treatment of uterine leiomyomas. Methods: The trans-abdominal ultrasound images of 63 patients before and after HIFU treatment of uterine leiomyomas were compared. Results: The volume and blood flow of leiomyomas were reduced after the HIFU treatment. Conclusion: Trans-abdominal ultrasound is a valuable method for evaluating the results of HIFU treatment of uterine leiomyomas. (authors)

  8. Ultrasound in the evaluation of enthesitis: status and perspectives.

    LENUS (Irish Health Repository)

    Gandjbakhch, Frédérique

    2011-01-01

    An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter.

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  10. Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLLEGE LONDON; Huthwaite, Peter [IMPERIAL COLLEGE LONDON; Rosenberg, Robert [UNM; Williamson, Michael [UNM

    2010-01-01

    Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  12. The Indian ultrasound paradox

    OpenAIRE

    Akbulut-Yuksel, Mevlude; Rosenblum, Daniel

    2012-01-01

    The liberalization of the Indian economy in the 1990s made prenatal ultrasound technology affordable and available to a large fraction of the population. As a result, ultrasound use amongst pregnant women rose dramatically in many parts of India. This paper provides evidence on the consequences of the expansion of prenatal ultrasound use on sex-selection. We exploit state-by-cohort variation in ultrasound use in India as a unique quasi-experiment. We find that sex-selective abortion of female...

  13. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training....

  14. [Ultrasound findings in rhabdomyolysis].

    Science.gov (United States)

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  15. Classification of prostate cancer grade using temporal ultrasound: in vivo feasibility study

    Science.gov (United States)

    Ghavidel, Sahar; Imani, Farhad; Khallaghi, Siavash; Gibson, Eli; Khojaste, Amir; Gaed, Mena; Moussa, Madeleine; Gomez, Jose A.; Siemens, D. Robert; Leveridge, Michael; Chang, Silvia; Fenster, Aaron; Ward, Aaron D.; Abolmaesumi, Purang; Mousavi, Parvin

    2016-03-01

    Temporal ultrasound has been shown to have high classification accuracy in differentiating cancer from benign tissue. In this paper, we extend the temporal ultrasound method to classify lower grade Prostate Cancer (PCa) from all other grades. We use a group of nine patients with mostly lower grade PCa, where cancerous regions are also limited. A critical challenge is to train a classifier with limited aggressive cancerous tissue compared to low grade cancerous tissue. To resolve the problem of imbalanced data, we use Synthetic Minority Oversampling Technique (SMOTE) to generate synthetic samples for the minority class. We calculate spectral features of temporal ultrasound data and perform feature selection using Random Forests. In leave-one-patient-out cross-validation strategy, an area under receiver operating characteristic curve (AUC) of 0.74 is achieved with overall sensitivity and specificity of 70%. Using an unsupervised learning approach prior to proposed method improves sensitivity and AUC to 80% and 0.79. This work represents promising results to classify lower and higher grade PCa with limited cancerous training samples, using temporal ultrasound.

  16. Ultrasound waiting lists: rational queue or extended capacity?

    Science.gov (United States)

    Brasted, Christopher

    2008-06-01

    The features and issues regarding clinical waiting lists in general and general ultrasound waiting lists in particular are reviewed, and operational aspects of providing a general ultrasound service are also discussed. A case study is presented describing a service improvement intervention in a UK NHS hospital's ultrasound department, from which arises requirements for a predictive planning model for an ultrasound waiting list. In the course of this, it becomes apparent that a booking system is a more appropriate way of describing the waiting list than a conventional queue. Distinctive features are identified from the literature and the case study as the basis for a predictive model, and a discrete event simulation model is presented which incorporates the distinctive features.

  17. Comparison of ultrasound and ultrasound plus nerve stimulator guidance axillary plexus block

    International Nuclear Information System (INIS)

    Demirelli, G.; Baskan, S.; Karabeyoglu, I.; Aytac, I.; Omek, D.H.; Erdogmus, A.; Baydar, M.

    2017-01-01

    To evaluate the characteristics of axillary plexus blockade applied using ultrasound only and using ultrasound together with nerve stimulator in patients undergoing planned forearm, wrist or hand surgery. Methods: This randomised, prospective, double-blinded, single-centre study was conducted at Ankara Numune Training and Research Hospital, Ankara, Turkey, from November 2014 to August 2015, and comprised patients undergoing forearm, wrist or hand surgery. Participants were separated into 2 groups. In Group 1, the nerve roots required for the surgical site were located one by one and local anaesthetic was applied separately to each nerve for the block. In Group 2, the vascular nerve bundle was located under ultrasound guidance and a total block was achieved by administering all the local anaesthetic within the nerve sheath. In the operating room, standard monitorisation was applied. Following preparation of the skin, the axillary region nerve roots and branches and vascular structures were observed by examination with a high-frequency ultrasound probe. In both groups, a 22-gauge, 5cm block needle was entered to the axillary region with visualisation of the whole needle on ultrasound and 20ml local anaesthetic of 0.5% bupivacaine was injected. SPSS 19 was used for data analysis. Results: Of the 60 participants, there were 30(50%) in each group. The mean age was 39.1+-15 years in the group 1 which was the ultrasound nerve stimulation group, and 41.5+-14.3 years in group 2. The duration of the procedure was longer in group I than in group 2 (p<0.05). Patient satisfaction values during the procedure were higher in group 2(p<0.05). In the ulnar sensory examination, the values of the patients in group 1 were higher at 10, 15, 20 and 25 minutes (p<0.05). In the median, radial and ulnar motor examination, the values of the patients in group 1were higher at 15 and 20 minutes (p<0.05). Conclusion: Brachial plexus blockade via axillary approach guided by ultrasound offered

  18. Neuromuscular ultrasound of cranial nerves.

    Science.gov (United States)

    Tawfik, Eman A; Walker, Francis O; Cartwright, Michael S

    2015-04-01

    Ultrasound of cranial nerves is a novel subdomain of neuromuscular ultrasound (NMUS) which may provide additional value in the assessment of cranial nerves in different neuromuscular disorders. Whilst NMUS of peripheral nerves has been studied, NMUS of cranial nerves is considered in its initial stage of research, thus, there is a need to summarize the research results achieved to date. Detailed scanning protocols, which assist in mastery of the techniques, are briefly mentioned in the few reference textbooks available in the field. This review article focuses on ultrasound scanning techniques of the 4 accessible cranial nerves: optic, facial, vagus and spinal accessory nerves. The relevant literatures and potential future applications are discussed.

  19. The fluoro-less and contrast-less peripheral endovascular intervention: Halfway there

    Energy Technology Data Exchange (ETDEWEB)

    Ephrem, Georges, E-mail: g.ephrem@gmail.com; Garikipati, Sireesha; Hanson, Ivan D.

    2016-09-15

    Introduction: Percutaneous endovascular revascularization requires the use of fluoroscopic guidance and radiopaque contrast. We present a successful intervention without the use of iodinated contrast. Case: A 92-year-old man with dry gangrene involving the second and fourth left toes had acute on chronic kidney injury. Arterial duplex showed severe stenosis in bilateral superficial femoral arteries (SFAs). Fluoroscopic and ultrasound guidance and intravascular imaging were used to avoid iodinated contrast. After right to left femoral crossover, the entire left SFA was imaged with ultrasound. The lesion was delineated with radiopaque measuring tapes then wired. Near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging were performed. Points of interest were correlated with corresponding radiopaque markings on the ruler. Stenting and post-dilation resulted in complete stent expansion and no evidence of dissection by IVUS. The total procedure time was 113 min and the total radiation dose 813 mGy. The day after the procedure, there was a palpable dorsalis pedis pulse. He was discharged to inpatient rehabilitation on dual antiplatelet therapy. Discussion: Contrast and radiation continue to limit the feasibility of endovascular angiography and intervention. Carbon dioxide (CO2) digital subtraction angiography is an alternative for these patients but has several disadvantages. Previously proposed projects demonstrated the real potential of performing endovascular peripheral intervention without fluoroscopy or contrast. Conclusion: This case is a clear demonstration of a successful use of a combination of fluoroscopy, ultrasonography and intravascular imaging to achieve a successful endovascular intervention to treat critical limb ischemia, without the use of iodinated contrast.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...