Sample records for intravascular ultrasound study

  1. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    Science.gov (United States)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  2. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  3. Association of insulin resistance and coronary artery remodeling: an intravascular ultrasound study

    OpenAIRE

    Kim, Sang-Hoon; Moon, Jae-Youn; Lim, Yeong Min; Kim, Kyung Ho; Yang, Woo-In; Sung, Jung-Hoon; Yoo, Seung Min; Kim, In Jai; Lim, Sang-Wook; Cha, Dong-Hun; Cho, Seung-Yun

    2015-01-01

    Background There are few studies that investigated the correlation between insulin resistance (IR) and the coronary artery remodeling. The aim of the study is to investigate the association of IR measured by homeostasis model assessment of insulin resistance (HOMA-IR) and coronary artery remodeling evaluated by intravascular ultrasound (IVUS). Methods A total of 298 consecutive patients who received percutaneous coronary interventions under IVUS guidance were retrospectively enrolled. The val...

  4. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  5. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...

  6. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    Introduction: Drug-eluting stents (DES) reduce the risk of restenosis after percutaneous coronary intervention. The aim of the study was to evaluate, by intravascular ultrasound (IVUS), the minimum lumen area site in the stented segment and the distribution of intimal hyperplasia in patients...

  7. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  8. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    Two morphological methods for quantifying the degree of stenoses in the iliac arteries, intravascular ultrasound (IVUS) and arteriography, were compared with duplex scanning, a method of evaluating the haemodynamic importance of the stenosis. A total of 38 patients, 20 women and 18 men, median age...... 66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...

  9. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  10. Intravascular Ultrasound Catheter Evaluation of the Left Ventricle in Mice: A Feasibility Study.

    Science.gov (United States)

    Gardin, Julius M.; Siri, Francis; Kitsis, Richard N.; Leinwand, Leslie

    1996-11-01

    With the advent of transgenic technology, it has become increasingly important to find a method for evaluating left ventricular (LV) anatomy and function in intact wild type, intervened, and transgenic mice. Mice are 1/10th the size of rats, and have body masses of 10-60 g, LV masses of 40-150 mg, LV wall thicknesses of 0.5-2 mm, and LV internal dimensions of 1-3 mm. Although the murine LV has been imaged by transthoracic (TTE) two-dimensional directed M-mode echocardiography, we explored the use of intravascular ultrasound (IVUS) catheters, with imaging from various positions, to see if better two-dimensional images of the LV could be obtained by IVUS than TTE. Eight normal mice were anesthetized using pentobarbital or avertin. The mice were studied using a commercially available IVUS system (Endosonics, Inc.). Two IVUS catheters (3.5 and 5.0 Fr) with 20-MHz multielement array transducers were used. Each catheter had a 4.0-mm imaging depth of field in all directions (360 degrees ) from the mid-point of the catheter core. Multiple imaging approaches were attempted: transesophageal (TEE); transjugular (TJ); transperitoneal (TP); and open chest, from both epicardial surface (Ep) and via direct LV puncture. TEE and TJ approaches afforded insufficient depth of field to image the entire LV in cross section. TP and Ep approaches resulted in poor images, related both to inadequate depth of field and to relatively small sector angles subtended by imaging elements. LVP (intracavitary imaging) was capable of satisfactorily imaging the LV epicardium, but was unable to image the endocardium, probably because the latter was within the 1.9-mm "ringdown" catheter artifact. All IVUS approach studies lacked sufficient temporal resolution (10 frames/sec) to reliably display systolic and diastolic frames necessary for evaluation of LV function. In contrast, as previously reported, transthoracic two-dimensionally directed M-mode echocardiograms have sufficient temporal and spatial

  11. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  12. Mapping intravascular ultrasound controversies in interventional cardiology practice

    NARCIS (Netherlands)

    Maresca, David; Adams, Samantha; Maresca, Bruno; van der Steen, Antonius F W

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  13. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  14. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  15. Intravascular Ultrasound and its Use in Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Klepanec, A.; Vulev, I.; Vozar, M.; Balazs, T.; Madaric, J.; Holoman, M.

    2009-01-01

    Intravascular ultrasound has become in invasive vascular radiology in the last decade the important part of diagnostic and also therapeutic procedures in management of vascular diseases. The basic possibilities for the use of IVUS include diagnostic procedures in vascular pathology assessment and therapeutic indications in the field of peripheral vascular interventions (PVI). Unlike other image modalities (CT, MRI, ultrasound) IVUS enables gather unique image in r eal time r ight from the vessel lumen, what helps to add important information regarding vessel wall, plate morphology, thrombi and cross-sectional vessel area. After initial use of intravascular ultrasound in coronary circulation, using IVUS is nowadays widely extended especially in aortic diseases, carotid and renal arteries and arteries of the lower extremities. This review article summarizes possibilities of intravascular ultrasound utilization in diagnostic process and therapy from peripheral vascular diseases up to thoracoabdominal aorta diseases and our experience with this new diagnostic modality. (author)

  16. Impact of statins on progression of atherosclerosis: rationale and design of SATURN (Study of Coronary Atheroma by InTravascular Ultrasound: effect of Rosuvastatin versus AtorvastatiN).

    Science.gov (United States)

    Nicholls, Stephen J; Borgman, Marilyn; Nissen, Steven E; Raichlen, Joel S; Ballantyne, Christie; Barter, Philip; Chapman, M John; Erbel, Raimund; Libby, Peter

    2011-06-01

    Previous imaging studies have demonstrated that the beneficial impact of high-dose statins on the progression of coronary atherosclerosis associates with their ability to lower levels of low-density lipoprotein cholesterol (LDL-C) and C-reactive protein (CRP) and to raise high-density lipoprotein cholesterol (HDL-C). The Study of Coronary Atheroma by InTravascular Ultrasound: Effect of Rosuvastatin versus AtorvastatiN (SATURN, NCT00620542) aims to compare the effects of high-dose atorvastatin and rosuvastatin on disease progression. A total of 1385 subjects with established coronary artery disease (CAD) on angiography were randomized to receive rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The primary efficacy parameter will be the nominal change in percent atheroma volume (PAV), determined by analysis of intravascular ultrasound (IVUS) images of matched coronary artery segments acquired at baseline and at 24-month follow-up. The effect of statin therapy on plasma lipids and inflammatory markers, and the incidence of clinical cardiovascular events will also be assessed. The study does not have the statistical power to directly compare the treatment groups with regard to clinical events. Serial IVUS has emerged as a sensitive imaging modality to assess the impact of treatments on arterial structure. In this study, IVUS will be used to determine whether high-dose statins have different effects on plaque progression.

  17. Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease.

    Science.gov (United States)

    De Maria, Giovanni Luigi; Banning, Adrian P

    2017-05-01

    Due to its potential prognostic implications and technical complexity, revascularisation of left main coronary artery (LMCA) disease requires careful consideration. Since publication of the results of the SYNTAX study, and more recently the EXCEL and NOBLE trials, there has been particular interest in percutaneous revascularisation of the LMCA. It is becoming clear that percutaneous revascularisation of LMCA disease requires appropriate lesion preparation and carefully optimised stenting in order to offer patients a treatment option as effective as coronary artery bypass grafting. For this reason intravascular imaging, and especially intravascular ultrasound, is becoming a key procedural step in LMCA percutaneous coronary intervention. In the current review paper we analyse the role of intravascular imaging with intravascular ultrasound in LMCA percutaneous coronary intervention, focusing on the main applications in this context from lesion assessment to stent sizing and optimisation.

  18. Discrimination of intravascular lumen and dissections in single intravascular ultrasound images using subtraction, conventional averaging and saline flush

    NARCIS (Netherlands)

    G. Pasterkamp (Gerard); M.S. van der Heiden (M.); M.J. Post (Mark); C. Borst (Cornelius); E.J. Gussenhoven (Elma); H. Pieterman; H. van Urk (Hero); N. Bom (Klaas)

    1995-01-01

    textabstractWith current 30-MHz intravascular ultrasound systems, flowing blood may cause considerable backscatter which in real-time images is characterized by dynamic speckle. However, in a single intravascular ultrasound image (still-frame) the discrimination between arterial lumen and wall may

  19. Monitoring of allograft vasculopathy by intravascular ultrasound one month and one year after heart transplantation: A single center study.

    Science.gov (United States)

    Bedanova, Helena; Orban, Marek; Tretina, Martin; Fila, Petr; Horvath, Vladimir; Krejci, Jan; Nemec, Petr

    2016-03-01

    The aim of this trial was to use intravascular ultrasound (IVUS) to determine whether cardiac allograft vasculopathy (CAV) starts progressing during the first year after heart transplantation (HTx). We retrospectively analyzed 51 patients (11 women) who received heart transplants in our center between January 2010 and September 2013 and underwent coronary angiography as well as IVUS examination one month and one year after HTx. Patients with proven calcification and fibrotic plates in the IVUS examination one month after HTx constituted a group with defined donor-transmitted atherosclerosis (DTA). In patients without DTA, measurements of maximal intimal thickening (MIT) were made in two predetermined locations. Eight of the 51 patients had DTA, while 43 did not. These were divided based on maximal intimal thickness (MIT) into a group with MIT first year after HTx significantly more frequently in patients with DTA and MIT ≥ 0.5 mm. It is essential in these patients to implement an IVUS control examination one year after transplantation. The results can lead to a change in treatment strategy to prevent further progress of the disease.

  20. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  1. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  2. Front-end IC design for intravascular ultrasound imaging

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel; Cenkeramaddi, Linga Reddy; Bozkurt, Ayhan

    2008-01-01

    Capacitive micromachined ultrasonic transducers(cMUT) technology is a new trend for intravascular ultrasound (IVUS) imaging. Large bandwidth, high sensitivity and compatibility to CMOS processes makes the cMUT a better choice compared to the conventional piezoelectric transducer. To exploit the merits of cMUT technology, an accurately designed front end circuit is required. The circuit functions as an output pulse driver for the generation of the acoustic signal and buffers the return echo. F...

  3. Antiatherosclerotic effects of long-term maximally intensive statin therapy after acute coronary syndrome: insights from Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin.

    Science.gov (United States)

    Puri, Rishi; Nissen, Steven E; Shao, Mingyuan; Ballantyne, Christie M; Barter, Philip J; Chapman, M John; Erbel, Raimund; Libby, Peter; Raichlen, Joel S; Uno, Kiyoko; Kataoka, Yu; Nicholls, Stephen J

    2014-11-01

    Patients with acute coronary syndromes (ACS) display diffuse coronary atheroma instability and heightened risk of early and late recurrent coronary events. We compared the long-term antiatherosclerotic efficacy of high-intensity statins in patients with ACS when compared with stable disease. Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin (SATURN) used serial intravascular ultrasound measures of coronary atheroma volume in patients treated with rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The overall effect of high-intensity statins on the change in coronary percent atheroma volume and major adverse cardiovascular events (death/nonfatal myocardial infarction/coronary revascularization) were evaluated in this post hoc analysis. When compared with non-ACS patients (n=678), patients with ACS (n=361) were younger, actively smoking, and have had a previous myocardial infarction (all P<0.001). At baseline, patients with ACS exhibited lower high-density lipoprotein cholesterol (43.5±11 versus 45.8±11 mg/dL; P=0.002), a higher apolipoprotein B: apolipoprotein A-1 ratio (0.90±0.24 versus 0.83±0.24; P<0.001) and greater percent atheroma volume (37.3±8.5% versus 35.9±8.1%; P=0.01) when compared with non-ACS patients. Despite similar achieved levels of lipid and inflammatory markers after high-intensity statin therapy, patients with ACS demonstrated greater percent atheroma volume regression than non-ACS patients (-1.46±0.14 versus -0.89±0.13; P=0.003). After propensity-weighted multivariable adjustment, baseline percent atheroma volume (P<0.001) and an ACS clinical presentation (P=0.02) independently associated with plaque regression. The 24-month major adverse cardiovascular events-free survival was similar between patients with ACS and non-ACS (90.6 versus 92.9%; P=0.25). Long-term high-intensity statin therapy caused greater plaque regression and comparable major adverse cardiovascular events rates in

  4. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-06-01

    We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures.

  5. Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies.

    Science.gov (United States)

    Steinvil, Arie; Zhang, Yao-Jun; Lee, Sang Yeub; Pang, Si; Waksman, Ron; Chen, Shao-Liang; Garcia-Garcia, Hector M

    2016-08-01

    The use of intravascular ultrasound (IVUS) guidance for drug-eluting stent (DES) optimization is limited by the number of adequately powered randomized control trials (RCTs). We performed an updated meta-analysis, including data from recently published RCTs and observational studies, by reviewing the literature in Medline and the Cochrane Library to identify studies that compared clinical outcomes between IVUS-guided and angiography-guided DES implantation from January 1995 to January 2016. This meta-analysis included 25 eligible studies, including 31,283 patients, of whom 3192 patients were enrolled in 7 RCTs. In an analysis of all 25 studies, the summary results for all the events analyzed were significantly in favor of IVUS-guided DES implantation [major adverse cardiac events (MACE, odds ratio [OR] 0.76, 95% confidence intervals [CI]: 0.70-0.82, PDES implantation was found only for MACE (OR 0.66, 95% CI: 0.52-0.84, P=0.001), TLR (OR 0.61, 95% CI: 0.43-0.87, P=0.006), and TVR (OR 0.61, 95% CI: 0.41-0.90, P=0.013). IVUS-guided percutaneous coronary intervention was associated with better overall clinical outcomes than angiography-guided DES implantation. However, in a solely RCT meta-analysis, this benefit was mainly driven by reduced rates of revascularizations. Copyright © 2016. Published by Elsevier Ireland Ltd.

  6. Recurring extracranial internal carotid artery vasospasm detected by intravascular ultrasound.

    Science.gov (United States)

    Dembo, Tomohisa; Tanahashi, Norio

    2012-01-01

    A 24-year-old woman presented with headache and left-sided focal signs following multiple episodes of right monocular visual impairment. Magnetic resonance angiography revealed a decreased vascular image intensity due to a suspicious stenosis in the right internal carotid artery (ICA). The stenosis was not demonstrated on duplex sonography as it was beyond the field of view of the investigation. Intravascular ultrasound (IVUS) revealed that the outer vessel diameter was significantly reduced during stenosis, supporting the presence of vasospasm. Idiopathic recurrent extracranial ICA vasospasm was diagnosed. Recurrent vasospasms of extracranial ICA may be a distinct entity that can cause ischemic stroke.

  7. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  8. Low variation and high reproducibility in plaque volume with intravascular ultrasound

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik

    2004-01-01

    BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied by electrocardiog......BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied...... by electrocardiographic-gated three-dimensional (3D) IVUS in 20 male patients with ischaemic heart disease (IHD). RESULTS: The study lesions were angiographically insignificant, with a length of the analysed segment on 11.4+/-5.9 mm. At baseline the mean minimal lumen diameter was 2.41+/-0.59 mm, minimal lumen area 4......=0.804; pIVUS is a highly reproducible method when applied on coronary artery...

  9. Serial intravascular ultrasound assessment of changes in coronary atherosclerotic plaque dimensions and composition: an update

    DEFF Research Database (Denmark)

    Hartmann, Marc; Huisman, Jennifer; Böse, Dirk

    2011-01-01

    This manuscript reviews the use of serial intravascular ultrasound (IVUS) examination of coronary atherosclerosis in recent observational studies and randomized trials that revealed the effects of cholesterol-lowering and lipid-modifying therapies and offered novel insight into plaque progression....... Finally, we report on the evaluation of true vessel remodelling in recent serial IVUS trials and discuss the future perspective of serial invasive imaging of coronary atherosclerosis....

  10. The clinical importance and prediction of steal following femoro-femoral cross-over bypass: study of the donor iliac artery by intravascular ultrasound, arteriography, duplex scanning and pressure measurements

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, J G; Schroeder, T V

    2000-01-01

    to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal.......to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal....

  11. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  12. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...

  13. Intravascular ultrasound assessment of remodelling and reference segment plaque burden in type-2 diabetic patients

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2007-01-01

    AIMS: Intravascular ultrasound (IVUS) assesses arterial remodelling by comparing the lesion external elastic membrane (EEM) with the reference segments; however, reference segments are rarely disease-free. The aim was to assess lesion and reference segment remodelling and plaque burden in patients...... with type-2 diabetes mellitus. METHODS AND RESULTS: We used pre-intervention IVUS to study 62 de novo lesions in 43 patients with type-2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal...... IVUS lumen and quantitative coronary angiographic artery...

  14. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    NARCIS (Netherlands)

    J.M.R. Ligthart (Jürgen); M-C. Morice (Marie-Claude); P.J. de Feyter (Pim); M. Degertekin (Muzaffer); K. Tanabe (Kengo); J.E. Sousa (Eduardo); A. Colombo (Antonio); G. Guagliumi (Giulio); W. Wijns (William); W.K. Lindeboom (Wietze); P.W.J.C. Serruys (Patrick); A.C. Abizaid (Alexandre)

    2002-01-01

    textabstractBACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238

  15. Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: A meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

    NARCIS (Netherlands)

    Y. Zhang (Yaojun); V. Farooq (Vasim); H.M. Garcia-Garcia (Hector); C.V. Bourantas (Christos); N.-L. Tian (Nai-Liang); S.-J. Dong (Sheng-Jie); M. Li (Minghui); S. Yang (Shengyun); P.W.J.C. Serruys (Patrick); S.-L. Chen (Shao-Liang)

    2012-01-01

    textabstractAims: The impact of intravascular ultrasound (IVUS) guided coronary drug-eluting stent (DES) implantation on clinical outcomes remains controversial. A meta-analysis of the currently available clinical trials investi-gating IVUS-guided DES implantation was undertaken. Methods and

  16. Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study.

    Science.gov (United States)

    Arnold, Roman; Villa, Adolfo; Gutiérrez, Hipólito; Sánchez, Pedro L; Gimeno, Federico; Fernández, Maria E; Gutiérrez, Oliver; Mota, Pedro; Sánchez, Ana; García-Frade, Javier; Fernández-Avilés, Francisco; San Román, Jose A

    2010-06-01

    We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy. Copyright 2010 Mosby, Inc. All rights reserved.

  17. Comparison of change in coronary atherosclerosis in patients with stable versus unstable angina pectoris receiving statin therapy (from the Treatment With Statin on Atheroma Regression Evaluated by Intravascular Ultrasound With Virtual Histology [TRUTH] study).

    Science.gov (United States)

    Nozue, Tsuyoshi; Yamamoto, Shingo; Tohyama, Shinichi; Fukui, Kazuki; Umezawa, Shigeo; Onishi, Yuko; Kunishima, Tomoyuki; Sato, Akira; Nozato, Toshihiro; Miyake, Shogo; Takeyama, Youichi; Morino, Yoshihiro; Yamauchi, Takao; Muramatsu, Toshiya; Hibi, Kiyoshi; Terashima, Mitsuyasu; Michishita, Ichiro

    2013-04-01

    Although statin-induced regression in coronary atherosclerosis seems to be greater in patients with acute coronary syndrome than in those with stable coronary artery disease, no reports have examined this. The purpose of the present study was to compare the changes in coronary atherosclerosis in patients with stable versus unstable angina pectoris (AP). The effects of 8-month statin therapy on coronary atherosclerosis were evaluated using virtual histology intravascular ultrasound, and analyzable intravascular ultrasound data were obtained from 119 patients (83 patients with stable AP and 36 with unstable AP). A significant decrease in plaque volume was observed in patients with unstable AP (-2.2%, p = 0.02) but not in patients with stable AP. A significant increase in the necrotic-core component (0.30 mm(3)/mm, p = 0.009) was observed only in patients with unstable AP. Significant positive correlations were observed between the percentage of change in platelet-activating factor acetylhydrolase and the percentage of change in plaque volume (r = 0.346, p = 0.05) in patients with unstable AP. No significant correlations were observed in patients with stable AP. Multivariate regression analyses showed that a reduction in platelet-activating factor acetylhydrolase was associated with regression in coronary atherosclerosis, particularly of the fibrous component (β = 0.443, p = 0.003), in patients with unstable AP. In conclusion, regression of the coronary artery plaque volume was greater, although statin therapy did not halt the increases in plaque vulnerability, in patients with unstable AP compared to those with stable AP. A reduction in the serum platelet-activating factor acetylhydrolase level was associated with regression in coronary atherosclerosis, particularly the fibrous plaque volume, in patients with unstable AP. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Relationship between intravascular ultrasound parameters and fractional flow reserve in intermediate coronary artery stenosis of left anterior descending artery: intravascular ultrasound volumetric analysis.

    Science.gov (United States)

    Yang, Hyoung-Mo; Tahk, Seung-Jea; Lim, Hong-Seok; Yoon, Myeong-Ho; Choi, So-Yeon; Choi, Byoung-Joo; Jin, Xiong Jie; Hwang, Gyo-Seung; Park, Jin-Sun; Shin, Joon-Han

    2014-02-15

    The objective of this study was to assess the relationship between intravascular ultrasound (IVUS) parameters, including volumetric analysis, and fractional flow reserve (FFR). Although it is known that coronary atherosclerosis burden measured by IVUS volumetric analysis is related with clinical outcomes, its relationship with functional significance remains unknown. Both IVUS and FFR were performed in 206 cases of intermediate stenosis of the left anterior descending artery (LAD). Myocardial ischemia was assessed by FFR and maximal hyperemia was induced by continuous intracoronary adenosine infusion. FFR  0.80 were associated with larger plaque volume (181.8 ± 82.3 vs. 125.9 ± 77.9 mm3, P < 0.001) and PAV (58.9 ± 5.6 vs. 53.8 ± 7.9%, P < 0.001). IVUS parameters representing severity and extent of atheromatous plaque correlated with functional significance in LAD lesions with intermediate stenosis.

  19. Reproducibility of intravascular ultrasound radiofrequency data analysis (virtual histology) with a 45-MHz rotational imaging catheter in ex vivo human coronary arteries

    NARCIS (Netherlands)

    T. Muramatsu (Takashi); H.M. Garcia-Garcia (Hector); S. Brugaletta (Salvatore); J.H. Heo (Jungho); Y. Onuma (Yoshinobu); R.J. Fedewa (Russell J.); A. Nair (Anuja); Y. Ozaki (Yukio); P.W.J.C. Serruys (Patrick)

    2015-01-01

    textabstractBackground: Despite the frequent use of spectral analysis of intravascular ultrasound radiofrequency data (VH® IVUS) in clinical studies, the assessment for reproducibility using this with high frequency IVUS remains unexplored. Purpose: The aim of this study was to examine the

  20. The Imaging Modulography Technique Revisited for High-Definition Intravascular Ultrasound: Theoretical Framework.

    Science.gov (United States)

    Tacheau, Antoine; Le Floc'h, Simon; Finet, Gérard; Doyley, Marvin M; Pettigrew, Roderic I; Cloutier, Guy; Ohayon, Jacques

    2016-03-01

    Mechanical characterization of atherosclerotic lesions remains an essential step for the detection of vulnerable plaques (VPs). Recently, an intravascular ultrasound (IVUS) elasticity reconstruction method (iMOD) has been tested in vivo by our group. The major limitation of iMOD is the need to estimate the strain field in the entire VP despite attenuated depth penetration signals when using high-definition (HD) IVUS systems. Therefore, an extended iMOD approach (E-iMOD) was designed and applied to coronary lesions of patients imaged in vivo with IVUS. The E-iMOD method (i) quantified necrotic core areas with a mean absolute relative error of 3.5 ± 3.5% and (ii) identified Young's moduli of the necrotic cores and fibrous regions with mean values of 5.7 ± 0.8 kPa and 794.5 ± 22.0 kPa instead of 5 kPa and 800 kPa, respectively. This study demonstrates the potential of the improved HD-IVUS modulography technique E-iMOD to characterize coronary VPs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  1. Monolithic CMUT on CMOS Integration for Intravascular Ultrasound Applications

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F. Levent

    2012-01-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter based volumetric imaging arrays where the elements need to be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom designed CMOS receiver electronics from a commercial IC foundry. The CMUT on CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT to CMOS interconnection. This CMUT to CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire bonding method. Characterization experiments indicate that the CMUT on CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Experiments on a 1.6 mm diameter dual-ring CMUT array with a 15 MHz center frequency show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging CTOs located 1 cm away from the CMUT array. PMID:23443701

  2. Multimodality Intracoronary Imaging With Near-Infrared Spectroscopy and Intravascular Ultrasound in Asymptomatic Individuals With High Calcium Scores.

    Science.gov (United States)

    Madder, Ryan D; VanOosterhout, Stacie; Klungle, David; Mulder, Abbey; Elmore, Matthew; Decker, Jeffrey M; Langholz, David; Boyden, Thomas F; Parker, Jessica; Muller, James E

    2017-10-01

    This study sought to determine the frequency of large lipid-rich plaques (LRP) in the coronary arteries of individuals with high coronary artery calcium scores (CACS) and to determine whether the CACS correlates with coronary lipid burden. Combined near-infrared spectroscopy and intravascular ultrasound was performed in 57 vessels in 20 asymptomatic individuals (90% on statins) with no prior history of coronary artery disease who had a screening CACS ≥300 Agatston units. Among 268 10-mm coronary segments, near-infrared spectroscopy images were analyzed for LRP, defined as a bright yellow block on the near-infrared spectroscopy block chemogram. Lipid burden was assessed as the lipid core burden index (LCBI), and large LRP were defined as a maximum LCBI in 4 mm ≥400. Vessel plaque volume was measured by quantitative intravascular ultrasound. Vessel-level CACS significantly correlated with plaque volume by intravascular ultrasound ( r =0.69; P infrared spectroscopy ( r =0.24; P =0.07). Despite a high CACS, no LRP was detected in 8 (40.0%) subjects. Large LRP having a maximum LCBI in 4 mm ≥400 were infrequent, found in only 5 (25.0%) of 20 subjects and in only 5 (1.9%) of 268 10-mm coronary segments analyzed. Among individuals with a CACS ≥300 Agatston units mostly on statins, CACS correlated with total plaque volume but not LCBI. This observation may have implications on coronary risk among individuals with a high CACS considering that it is coronary LRP, rather than calcification, that underlies the majority of acute coronary events. © 2017 American Heart Association, Inc.

  3. Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications.

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F Levent

    2011-12-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Ex- periments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.

  4. Determinants of slow flow following stent implantation in intravascular ultrasound-guided primary percutaneous coronary intervention.

    Science.gov (United States)

    Watanabe, Yusuke; Sakakura, Kenichi; Taniguchi, Yousuke; Yamamoto, Kei; Wada, Hiroshi; Fujita, Hideo; Momomura, Shin-Ichi

    2018-03-01

    Slow flow is a serious complication in primary percutaneous coronary intervention (PCI) and is associated with poor clinical outcomes. Intravascular ultrasound (IVUS)-guided PCI may improve clinical outcomes after drug-eluting stent implantation. The purpose of this study was to seek the factors of slow flow following stent implantation, including factors related to IVUS-guided primary PCI. The study population consisted of 339 ST-elevation myocardial infarction patients, who underwent stent deployment with IVUS. During PCI, 56 patients (16.5%) had transient or permanent slow flow. Multivariate logistic regression analysis showed age (OR 1.04, 95% CI 1.01-1.07, P = 0.01), low attenuation plaque on IVUS (OR 3.38, 95% CI 1.70-6.72, P = 0.001), initial Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 (vs. TIMI 0: OR 0.44, 95% CI 0.20-0.99, P = 0.046), and the ratio of stent diameter to vessel diameter (per 0.1 increase: OR 2.63, 95% CI 1.84-3.77, P flow. A ratio of stent diameter to vessel diameter of 0.71 had an 80.4% sensitivity and 56.9% specificity to predict slow flow. There was no significant difference in ischemic-driven target vessel revascularization between the modest stent expansion (ratio of stent diameter to vessel diameter flow following stent implantation in IVUS-guided primary PCI.

  5. Expansion in calcific lesions and overall clinical outcomes following bioresorbable scaffold implantation optimized with intravascular ultrasound.

    Science.gov (United States)

    Kawamoto, Hiroyoshi; Ruparelia, Neil; Latib, Azeem; Miyazaki, Tadashi; Sato, Katsumasa; Tanaka, Akihito; Naganuma, Toru; Sticchi, Alessandro; Chieffo, Alaide; Carlino, Mauro; Montorfano, Matteo; Colombo, Antonio

    2017-04-01

    This study aimed to investigate clinical outcomes following bioresorbable scaffold (BRS) optimized with intravascular ultrasound (IVUS), and furthermore expansion of BRS in calcific lesions. Although IVUS use has contributed to improved clinical outcomes with metallic stent implantation, it is unclear if this is also true with regards to BRS, especially in calcified lesions. Between May 2012 and April 2015, 291 lesions in 198 patients were treated with BRS with IVUS use. We evaluated overall clinical outcomes at 1-year and investigated the expansion and eccentricity index of BRS amongst quadrants categorized by calcium arc (CA) every 90-degrees. The rates of major adverse cardiac events were 5.4% (at 6 months) and 10.7% (at 12 months). TLR was observed in 3.1% at 6-month and 7.5% at 12-month follow up. Although there was a significant difference among quadrants regarding to eccentricity of calcium (0°≦CA BRS expansion index [minimal scaffold area (MSA) divided by BRS area expanded at a nominal pressure] was comparable between quadrants. The use of IVUS to optimize BRS implantation results in favorable clinical outcomes even for complex lesions. Although eccentric calcium distribution resulted in asymmetric expansion of BRS, the final MSA was comparable irrespective of calcium distribution. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  7. Successful Intravascular Ultrasound-Guided Transradial Coronary Intervention with a 4Fr Guiding Catheter.

    Science.gov (United States)

    Nakano, Yasuhiro; Sadamatsu, Kenji

    2016-01-01

    Minimizing the catheter size can reduce vascular access complications and contrast dye usage in coronary angiography. The small diameter of the 4Fr guiding catheter has limited the use of several angioplasty devices such as intravascular ultrasound (IVUS) in the past. However, the combination of a novel IVUS catheter and a 0.010 guidewire makes it possible to perform IVUS-guided percutaneous coronary intervention (PCI) with a 4Fr guiding catheter. We herein report the case of a 51-year-old man with silent myocardial ischemia who underwent IVUS-guided transradial PCI with a 4Fr guiding catheter.

  8. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  9. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  10. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    International Nuclear Information System (INIS)

    Figueiredo, José Albuquerque Neto de; Nogueira, Iara Antonia Lustosa; Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio

    2013-01-01

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I 2 test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I 2 = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I 2 = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I 2 = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I 2 = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes

  11. Correlation between dual-axis rotational coronary angiography and intravascular ultrasound in a coronary lesion assessment.

    Science.gov (United States)

    Jin, Zhi-Geng; Zhang, Zhuo-Qi; Jing, Li-Min; Wei, Yu-Jie; Zhang, Jiao; Luo, Jian-Ping; Yang, Sheng-Li; Ma, Dong-Xing; Liu, Ying; Han, Wei; Yang, Yong; Liu, Hui-Liang

    2017-02-01

    The purpose of this study was to evaluate the accuracy of dual-axis rotational coronary angiography (DARCA) for coronary lesion assessment by directly comparing with intravascular ultrasound (IVUS). From October 2014 to December 2015, 40 patients (58 lesions) who had undergone both DARCA and IVUS were included in the image analysis. The minimum lumen diameter (MLD), lesion length, reference vessel diameter (RVD) and percent diameter stenosis at the same lesion, were identified and assessed. Significant correlation with IVUS was found for DARCA in either lesion length (r = 0.90, P < 0.001) or RVD (r = 0.81, P < 0.001) comparison. DARCA had fair correlation with IVUS for both MLD (r = 0.65, P < 0.001) and diameter stenosis (r = 0.48, P < 0.001). From the Bland-Altman plots, there was a good agreement between DARCA and IVUS regarding MLD (mean difference: -0.23 mm, 95 % limits of agreement: -0.96 to 0.50 mm) and RVD (mean difference: -0.15 mm, 95 % limits of agreement: -0.85 to 0.55 mm), while lesser agreement was found on lesion length (mean difference: -3.39 mm, 95 % limits of agreement: -12.63 to 5.85 mm) and diameter stenosis (mean difference: 4.82 %, 95 % limits of agreement: -17.05 to 26.68 %). There is an adequate correlation and agreement between DARCA and IVUS in coronary lesion assessment.

  12. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...

  13. Cardiac allograft vasculopathy compared by intravascular ultrasound sonography: everolimus to mycophenolate mofetil--one single-center experience.

    Science.gov (United States)

    Chou, N-K; Jan, C-F; Chi, N-H; Lee, C-M; Wu, I-H; Huang, S-C; Chen, Y-S; Yu, H-Y; Tsao, C-I; Ko, W-J; Chu, S-H; Wang, S-S

    2012-05-01

    Cardiac allograft vasculopathy (CAV) remains one of the leading causes of late graft failure and death. Cyclosporine microemulsion Neoral (CsA) had been used in heart transplantation (HTx) recipients. Meanwhile, Everolimus (EVL; Certican, Norvatis Pharmaceuticals; Basel, Switzerland) or mycophenolate mofetil (MMF) have been combined with CsA for maintenance treatment. We compared atherosclerosis in HTx patients showing CAV by intravascular ultrasound (IVUS) in two groups: the CE who received CsA, EVL, and steroid versus the CM group, who received CsA, MMF, and steroid. We explored IVUS parameters such as plaque thickness (PT), lumen circumference (LC), media adventitial circumference, lumen diameter (LD), and media adventitial diameter to characterize the atherosclerosis among CE versus CM groups. In this study, both the CE and CM groups showed increased plaque thickening in the first year posttransplantation (P data. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Characterization of a saphenous vein graft aneurysm by intravascular ultrasound and computerized three-dimensional reconstruction.

    Science.gov (United States)

    Ennis, B M; Zientek, D M; Ruggie, N T; Billhardt, R A; Klein, L W

    1993-04-01

    Aneurysmal dilatations in saphenous vein grafts are rare complications of coronary artery bypass surgery that mostly represent thin-wall pseudoaneurysms at anastomotic sites. We describe a case of an enlarging distal saphenous vein graft aneurysm in which intravascular ultrasound (IVUS) and computerized three-dimensional reconstruction (3DR) of the IVUS images was performed to conclusively demonstrate true aneurysm morphology. Although both atherosclerotic and nonatherosclerotic mechanisms for vein graft aneurysm formation have been previously suggested, IVUS images and 3DR of the aneurysm in this case did not reveal any of the features typical for atherosclerotic lesions. Further, the IVUS images and 3DR suggest that progressive atherosclerosis is not the likely cause of aneurysm formation in this case. This application of IVUS and 3DR provides detailed information about saphenous vein graft aneurysm structure, clues to aneurysm formation, and suggests a natural history that may differ from that of pseudoaneurysms.

  15. The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy

    DEFF Research Database (Denmark)

    Vogt, K C; Sillesen, H; Schroeder, T V

    1998-01-01

    To evaluate the application of intravascular ultrasound (IVUS) for intraoperative assessment of semiclosed thromboendarterectomy (TEA), IVUS images of the iliofemoral segment in 20 patients were obtained. The configuration and size of residual atherosclerotic material were evaluated. Stenoses...... was detected in the artery by IVUS. The material was removed in five cases. The part of the iliac artery proximal to the endarterectomized segment was visualized in 14 cases and showed minor stenoses in 10 cases. After follow-up at a median of 8 months (range 1-24), occlusion had occurred in one of 20 patients...... and restenosis (> 50%) had developed in two (10%). At this point, patency cannot be related to IVUS findings. We conclude that IVUS is a feasible method for intraoperative assessment of semiclosed TEA. The rate of early failures due to residual material might be reduced by this new application of IVUS....

  16. The role of Intravascular Ultrasound in the management of spontaneous coronary artery dissection

    Directory of Open Access Journals (Sweden)

    Karamitsos Theodoros D

    2008-05-01

    Full Text Available Abstract Primary or spontaneous coronary artery dissection (SCAD is an unusual but increasingly recognized cause of acute myocardial ischemia and sudden cardiac death. Typically, SCAD presents in younger patients without conventional risk factors for coronary artery disease. It occurs more commonly in women than in men, and frequently during pregnancy or the postpartum period. Its pathophysiology is poorly understood, and there is considerable controversy regarding the optimal management of patients with SCAD-related myocardial ischemia. Therapeutic approaches include conservative medical therapy, coronary artery bypass graft surgery and percutaneous coronary intervention (PCI. We present four cases of SCAD to illustrate specific aspects of the presentation and management of this condition, with particular reference to the importance of intravascular ultrasound (IVUS to aid diagnosis and guide subsequent PCI.

  17. Comparison of angiography and intravascular ultrasound before and after balloon angioplasty of the femoropopliteal artery

    International Nuclear Information System (INIS)

    Lankeren, Winnifred van; Gussenhoven, Elma J.; Pieterman, Herman; Sambeek, Marc R. H. M. van; Lugt, Aad van der

    1998-01-01

    Purpose: To compare angiographic and intravascular ultrasound (IVUS) data before and after balloon angioplasty (PTA) of the femoropopliteal artery.Methods: Qualitative and quantitative analyses were performed on corresponding angiographic and IVUS levels obtained from 135 patients.Results: IVUS detected more lesions, calcified lesions, and vascular damage than angiography. Sensitivity of angiography was good for the presence of a lesion (84%), moderate for eccentric lesions (53%) and for vascular damage (52%), and poor for calcified lesions (30%). The increase in angiographic diameter stenosis was associated with a decrease in lumen area and increase in percentage area stenosis on IVUS.Conclusions: Angiography is less sensitive than IVUS for detecting lesion eccentricity, calcified lesions, and vascular damage. Presence of a lesion and amount of plaque were underestimated angiographically. Only before PTA was good agreement found between angiographic diameter stenosis and lumen size on IVUS.

  18. Perspectives on Imaging the Left Main Coronary Artery Using Intravascular Ultrasound and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Harry C Lowe

    2015-01-01

    Full Text Available Percutaneous Coronary Intervention (PCI for significant left main coronary artery (LMCA stenosis is increasingly being viewed as a viable alternative to Coronary Artery Bypass Grafting (CABG (1. This is leading to an expectation of increasing numbers of such procedures, with a consequent focus on both the ability to image both lesion severity, and assess more accurately the results of PCI. While there have been advances in physiologic assessment of left main severity using fractional flow reserve (FFR, imaging of the LMCA using Intravascular Ultrasound (IVUS and more recently Optical Coherence Tomography (OCT has the specific advantage of being able to provide detailed anatomical information both pre and post PCI, such that it is timely to review briefly the current status of these two imaging technologies in the context of LMCA intervention.

  19. Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment.

    Science.gov (United States)

    Sheris, S J; Canos, M R; Weissman, N J

    2000-01-01

    High-resolution intravascular ultrasound (IVUS) performed immediately after stent deployment often reveals dissection at the stent margin that may not be appreciated by angiography. However, the natural history of these edge dissections is unknown. These intimal disruptions at the stent margins have been previously reported to occur in 5% to 23% of stent implantations. The short-term prognosis of these lesions appears to be good; however, the longer-term effect on restenosis and/or vessel remodeling is not known. We therefore studied a cohort of patients with the use of IVUS immediately after stent implantation and at 6 months to assess the incidence and prognosis of coronary edge dissections. One hundred fifty patients undergoing Palmaz-Shatz stent implantation were imaged with IVUS with the use of a motorized pullback, and the incidence of edge dissections was determined and graded according to depth and circumferential extent. Arterial and lesional morphometric parameters were assessed by digital planimetry. Six-month IVUS images were aligned with the poststent IVUS to determine the natural history of these lesions. Sixteen (10.7%) of 150 had edge tears. All were angiographically silent. Most lesions (n = 9) were superficial intimal tears. Vessel, lumen, and plaque area were similar in the nondissection and dissection groups in both the proximal and distal reference segments. Plaque eccentricity was likewise similar in both groups. At 6 months, lesions (n = 12) healed without a change in plaque burden, undergoing a "tacking down" process. Vessel area (19. 1 +/- 6.4 vs 18.4 +/- 7.1 mm(2), P = not significant), lumen area (8. 2 +/- 4.1 vs 9.2 +/- 4.0 mm(2), P = not significant), and plaque area (10.0 +/- 3.3 vs 9.8 +/- 3.3 mm(2), P = not significant) were unchanged when compared with the lesion site taken at stent deployment. Edge dissections as detected by IVUS do not necessarily proscribe an adverse prognosis at 6 months. This finding may provide reassurance to

  20. Segmentation of arterial walls in intravascular ultrasound cross-sectional images using extremal region selection.

    Science.gov (United States)

    Faraji, Mehdi; Cheng, Irene; Naudin, Iris; Basu, Anup

    2018-03-01

    Intravascular Ultrasound (IVUS) is an intra-operative imaging modality that facilitates observing and appraising the vessel wall structure of the human coronary arteries. Segmentation of arterial wall boundaries from the IVUS images is not only crucial for quantitative analysis of the vessel walls and plaque characteristics, but is also necessary for generating 3D reconstructed models of the artery. The aim of this study is twofold. Firstly, we investigate the feasibility of using a recently proposed region detector, namely Extremal Region of Extremum Level (EREL) to delineate the luminal and media-adventitia borders in IVUS frames acquired by 20 MHz probes. Secondly, we propose a region selection strategy to label two ERELs as lumen and media based on the stability of their textural information. We extensively evaluated our selection strategy on the test set of a standard publicly available dataset containing 326 IVUS B-mode images. We showed that in the best case, the average Hausdorff Distances (HD) between the extracted ERELs and the actual lumen and media were 0.22  mm and 0.45 mm, respectively. The results of our experiments revealed that our selection strategy was able to segment the lumen with ⩽0.3 mm HD to the gold standard even though the images contained major artifacts such as bifurcations, shadows, and side branches. Moreover, when there was no artifact, our proposed method was able to delineate media-adventitia boundaries with 0.31 mm HD to the gold standard. Furthermore, our proposed segmentation method runs in time that is linear in the number of pixels in each frame. Based on the results of this work, by using a 20 MHz IVUS probe with controlled pullback, not only can we now analyze the internal structure of human arteries more accurately, but also segment each frame during the pullback procedure because of the low run time of our proposed segmentation method. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

    Science.gov (United States)

    Rahman, Shahid; Leesar, Tara; Cilingiroglu, Mehmet; Effat, Mohamed; Arif, Imran; Helmy, Tarek; Leesar, Massoud A

    2013-09-01

    Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation. A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI. In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p impact on the MV stent volume or symmetry. This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...

  3. Resolution of spontaneous coronary artery dissection within 3 weeks detected by computed tomography angiography and intravascular ultrasound.

    Science.gov (United States)

    Tsutsui, Hiroshi; Chino, Chiharu; Komatsu, Miho; Sakai, Takahiro; Aizawa, Kazunori; Owa, Mafumi

    2017-01-01

    A 62-year-old woman was admitted with chest pain lasting about 3 h. Spontaneous coronary artery dissection (SCAD) was detected in the left anterior descending artery (LAD) by intravascular ultrasound (IVUS). Sixteen days after onset, follow-up computed tomography angiography was performed and revealed shrinkage of the false lumen of the SCAD. On hospital day 22, IVUS image confirmed that the SCAD in the LAD was completely healed. This case shows the possibility of rapid healing of SCAD.

  4. Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

    Science.gov (United States)

    Yoon, Sangpil; Williams, Jay; Kang, Bong Jin; Yoon, Changhan; Cabrera-Munoz, Nestor; Jeong, Jong Seob; Lee, Sang Goo; Shung, K Kirk; Kim, Hyung Ham

    2015-06-01

    A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

  5. Visualization of plaque distribution in a curved artery: three-dimensional intravascular ultrasound imaging.

    Science.gov (United States)

    Choi, Ahnryul; McPherson, David D; Kim, Hyunggun

    2017-12-01

    Intravascular ultrasound (IVUS) imaging provides an excellent tool for evaluation of the type, morphology, extent, and severity of an atheromatous plaque. 3 D IVUS imaging offers additive information pertaining to morphology of the arterial structures and volumetric plaque distributions. A new 3 D IVUS visualization technique was developed to provide 3 D structural information of a curved artery. A virtual 3 D curved arterial phantom consisting of varying cross-sectional shapes, wall thicknesses, and acoustic intensity information was utilized to validate the nonlinear interpolation technique to create intermediary 2 D IVUS images. IVUS imaging was performed for the iliofemoral arterial segment of an atherosclerotic Yucatan miniswine model. These in-vivo IVUS data were utilized for intermediary IVUS image generation and volumetric 3 D IVUS visualization. Smooth transitional changes of cross-sectional shape, wall thickness and grayscale intensity were found between the intermediary images and the original arterial phantom slices. The 3 D IVUS imaging of the unfolded curved iliofemoral artery provided realistic 3 D luminal surface images of the arteries with physiologic grayscale intensity information. This unique 3 D IVUS imaging technique may help with assessment of 3 D plaque distribution across the curved arterial structure, and improve 3 D visualization of atheromatous components.

  6. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  7. Diagnostic accuracy of integrated intravascular ultrasound and optical coherence tomography (IVUS-OCT) system for coronary plaque characterization

    Science.gov (United States)

    Li, Jiawen; Ma, Teng; Mohar, Dilbahar; Correa, Adrian; Minami, Hataka; Jing, Joseph; Zhou, Qifa; Patel, Pranav M.; Chen, Zhongping

    2014-03-01

    Intravascular ultrasound (IVUS) imaging and optical coherence tomography (OCT), two commonly used intracoronary imaging modalities, play important roles in plaque evaluation. The combined use of IVUS (to visualize the entire plaque volume) and OCT (to quantify the thickness of the plaque cap, if any) is hypothesized to increase plaque diagnostic accuracy. Our group has developed a fully-integrated dual-modality IVUS-OCT imaging system and 3.6F catheter for simultaneous IVUS-OCT imaging with a high resolution and deep penetration depth. However, the diagnostic accuracy of an integrated IVUS-OCT system has not been investigated. In this study, we imaged 175 coronary artery sites (241 regions of interest) from 20 cadavers using our previous reported integrated IVUS-OCT system. IVUS-OCT images were read by two skilled interventional cardiologists. Each region of interest was classified as either calcification, lipid pool or fibrosis. Comparing the diagnosis by cardiologists using IVUSOCT images with the diagnosis by the pathologist, we calculated the sensitivity and specificity for characterization of calcification, lipid pool or fibrosis with this integrated system. In vitro imaging of cadaver coronary specimens demonstrated the complementary nature of these two modalities for plaques classification. A higher accuracy was shown than using a single modality alone.

  8. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  9. Regression and shift in composition of coronary atherosclerotic plaques by pioglitazone: insight from an intravascular ultrasound analysis.

    Science.gov (United States)

    Clementi, Fabrizio; Di Luozzo, Marco; Mango, Ruggiero; Luciani, Giulio; Trivisonno, Antonio; Pizzuto, Francesco; Martuscelli, Eugenio; Mehta, Jawahar L; Romeo, Francesco

    2009-03-01

    Plaque reduction with the use of pioglitazone and statin combination therapy has been observed in carotid plaque. We sought to investigate the effect of combination therapy with statins and pioglitazone on coronary plaque regression and composition with the use of intravascular ultrasound (IVUS) and intravascular ultrasound-virtual histology (IVUS-VH). We analysed 29 plaques in 25 diabetic patients with angiographic evidence of nonsignificant coronary lesions with IVUS-VH. Patients were treated with 80 mg of atorvastatin and 30 mg of pioglitazone daily for 6 months. After 6 months of therapy, IVUS-VH of each lesion was reacquired. Mean elastic external membrane volume was significantly reduced between baseline and follow-up (343.9 vs. 320.5 mm; P < 0.05) as was mean total atheroma volume (179.3 vs. 166.6 mm; P < 0.05). Change in total atheroma volume showed a 6.3% mean reduction. Areas of fibrous tissue, fibrolipidic tissue and calcium decreased over the 6 months of follow-up, although not significantly. On the other hand, the necrotic core increased from 9 to 14% (P < 0.05). Our data demonstrated that atorvastatin/pioglitazone association is able to induce significant regression of coronary atherosclerosis, acting on plaque composition. Our findings are preliminary results and will be confirmed in an ongoing randomized placebo-controlled multicenter trial (PIPER; Pioglitazone for Prevention of Restenosis in Diabetics with Complex Lesion; trial registration: clinical trials.gov. Identifier: NCT 00376870).

  10. 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

    Science.gov (United States)

    Yeh, David T; Oralkan, Omer; Wygant, Ira O; O'Donnell, Matthew; Khuri-Yakub, Butrus T

    2006-06-01

    Forward-viewing ring arrays can enable new applications in intravascular and intracardiac ultrasound. This work presents compelling, full-synthetic, phased-array volumetric images from a forward-viewing capacitive micromachined ultrasonic transducer (CMUT) ring array wire bonded to a custom integrated circuit front end. The CMUT ring array has a diameter of 2 mm and 64 elements each 100 microm x 100 microm in size. In conventional mode, echo signals received from a plane reflector at 5 mm had 70% fractional bandwidth around a center frequency of 8.3 MHz. In collapse mode, 69% fractional bandwidth is measured around 19 MHz. Measured signal-to-noise ratio (SNR) of the echo averaged 16 times was 29 dB for conventional operation and 35 dB for collapse mode. B-scans were generated of a target consisting of steel wires 0.3 mm in diameter to determine resolution performance. The 6 dB axial and lateral resolutions for the B-scan of the wire target are 189 microm and 0.112 radians for 8 MHz, and 78 microm and 0.051 radians for 19 MHz. A reduced firing set suitable for real-time, intravascular applications was generated and shown to produce acceptable images. Rendered three-dimensional (3-D) images of a Palmaz-Schatz stent also are shown, demonstrating that the imaging quality is sufficient for practical applications.

  11. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...... diameter was 1.56 +/- 0.55 mm. The mean difference between the IVUS reference lumen diameter and angiographic reference lumen diameter was 0.18 +/- 0.44 mm. Plaque burden in the reference segment correlated inversely with the difference between IVUS and quantitative coronary angiographic reference lumen...

  12. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  13. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated...

  14. Clinical feasibility of 3D automated coronary atherosclerotic plaque quantification algorithm on coronary computed tomography angiography: Comparison with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung-Bok [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Myongji Hospital, Division of Cardiology, Cardiovascular Center, Goyang (Korea, Republic of); Lee, Byoung Kwon [Yonsei University College of Medicine, Division of Cardiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Shin, Sanghoon [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); National Health Insurance Corporation Ilsan Hospital, Division of Cardiology, Goyang (Korea, Republic of); Heo, Ran; Chang, Hyuk-Jae; Chung, Namsik [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of); Arsanjani, Reza [Cedars-Sinai Medical Center, Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Los Angeles, CA (United States); Kitslaar, Pieter H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical Imaging Systems B.V., Leiden (Netherlands); Broersen, Alexander; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Ahn, Sung Gyun [Yonsei University Wonju Severance Christian Hospital, Division of Cardiology, Wonju (Korea, Republic of); Min, James K. [New York-Presbyterian Hospital, Institute for Cardiovascular Imaging, Weill-Cornell Medical College, New York, NY (United States); Hong, Myeong-Ki; Jang, Yangsoo [Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS) were analyzed. Minimal lumen area (MLA), maximal lumen area stenosis percentage (%AS), mean plaque burden percentage (%PB), and plaque volume were measured semi-automatically by expert, non-expert, and fully automatic QCT analyses, and then compared to IVUS. Between IVUS and expert QCT analysis, the correlation coefficients (r) for the MLA, %AS, %PB, and plaque volume were excellent: 0.89 (p < 0.001), 0.84 (p < 0.001), 0.91 (p < 0.001), and 0.94 (p < 0.001), respectively. There were no significant differences in the mean parameters (all p values >0.05) except %AS (p = 0.01). The automatic QCT analysis showed comparable performance to non-expert QCT analysis, showing correlation coefficients (r) of the MLA (0.80 vs. 0.82), %AS (0.82 vs. 0.80), %PB (0.84 vs. 0.73), and plaque volume (0.84 vs. 0.79) when they were compared to IVUS, respectively. Fully automatic QCT analysis showed clinical utility compared with IVUS, as well as a compelling performance when compared with semiautomatic analyses. (orig.)

  15. Joint learning of ultrasonic backscattering statistical physics and signal confidence primal for characterizing atherosclerotic plaques using intravascular ultrasound.

    Science.gov (United States)

    Sheet, Debdoot; Karamalis, Athanasios; Eslami, Abouzar; Noël, Peter; Chatterjee, Jyotirmoy; Ray, Ajoy K; Laine, Andrew F; Carlier, Stephane G; Navab, Nassir; Katouzian, Amin

    2014-01-01

    Intravascular Ultrasound (IVUS) is a predominant imaging modality in interventional cardiology. It provides real-time cross-sectional images of arteries and assists clinicians to infer about atherosclerotic plaques composition. These plaques are heterogeneous in nature and constitute fibrous tissue, lipid deposits and calcifications. Each of these tissues backscatter ultrasonic pulses and are associated with a characteristic intensity in B-mode IVUS image. However, clinicians are challenged when colocated heterogeneous tissue backscatter mixed signals appearing as non-unique intensity patterns in B-mode IVUS image. Tissue characterization algorithms have been developed to assist clinicians to identify such heterogeneous tissues and assess plaque vulnerability. In this paper, we propose a novel technique coined as Stochastic Driven Histology (SDH) that is able to provide information about co-located heterogeneous tissues. It employs learning of tissue specific ultrasonic backscattering statistical physics and signal confidence primal from labeled data for predicting heterogeneous tissue composition in plaques. We employ a random forest for the purpose of learning such a primal using sparsely labeled and noisy samples. In clinical deployment, the posterior prediction of different lesions constituting the plaque is estimated. Folded cross-validation experiments have been performed with 53 plaques indicating high concurrence with traditional tissue histology. On the wider horizon, this framework enables learning of tissue-energy interaction statistical physics and can be leveraged for promising clinical applications requiring tissue characterization beyond the application demonstrated in this paper. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: the Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2008-01-01

    AIMS: Patients with diabetes have increased risk of in-stent restenosis after coronary stent implantation owing to neointimal hyperplasia (NIH). The aim of the study was to evaluate the extent and distribution of NIH with intravascular ultrasound (IVUS) after coronary artery stenting with sirolimus......-eluting (Cypher) or paclitaxel-eluting (Taxus) stents in diabetic patients. METHODS AND RESULTS: One hundred and thirty diabetic patients were randomized to Cypher or Taxus stent implantation. IVUS was performed at 8 month follow-up. NIH volume was significantly reduced in the Cypher group when compared...

  17. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan); Kishimoto, Junichi; Iwata, Naoki [Tottori University Hospital, Division of Clinical Radiology, Yonago (Japan)

    2015-09-15

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  18. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Kishimoto, Junichi; Iwata, Naoki

    2015-01-01

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  19. Safety and efficacy of intravascular ultrasound-guided inferior vena cava filter in super obese bariatric patients.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Barker, Michael; Macdonald, Kenneth G; Pender, John R; Chapman, William H

    2008-01-01

    The morbidly obese (body mass index >40 kg/m(2)) are at significant risk of postoperative venous thromboembolism (VTE). Pulmonary embolism is the leading cause of death after Roux-en-Y gastric bypass, approximating .5%. Because of the technical limitations with fluoroscopy and table weight limits, it has been our practice at our university-based bariatric center to offer intravascular ultrasound (IVUS)-guided inferior vena cava filter (IVCF) placement at Roux-en-Y gastric bypass to patients with a history of VTE, hypercoagulable state, or profound immobility. The hospital and outpatient records of all 594 patients who underwent Roux-en-Y gastric bypass from January 1, 2004 to October 31, 2006 were reviewed. The patients who had undergone concurrent IVUS-guided IVCF placement were selected. The co-morbidities, outcomes, and complications were recorded. Of the 594 patients, 31 (mean body mass index 71.2 +/- 2.96 kg/m(2)) had undergone concurrent IVUS-guided IVCF placement. The indications included a history of VTE (n = 5), a known hypercoagulable state (n = 2), and profound immobility (n = 25). The technical success rate was 96.8%. One filter was malpositioned in the iliac vein. No catheter site complications occurred. A ventilation/perfusion scan and computed tomography scan each detected pulmonary embolism in 2 surviving patients within 2 months postoperatively. Two patients died, 1 on postoperative day 8 and 1 on postoperative day 15 (6.4%). The mean follow-up time was 262.8 +/- 37.3 days. Autopsy excluded VTE or IVCF-related issues as the cause of death in both patients. These results suggest the efficacy of IVUS-guided IVCF placement in preventing mortality from pulmonary embolism in high-risk bariatric patients. IVUS-guided IVCF placement can be safely performed with an excellent success rate in high-risk patients who would not otherwise be candidates for intervention because of the technical limitations of fluoroscopy.

  20. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    International Nuclear Information System (INIS)

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-01-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization

  1. Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Lodi-Junqueira Lucas

    2012-09-01

    Full Text Available Abstract Background The role of intravascular ultrasound (IVUS in percutaneous coronary interventions (PCI is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies. Methods A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies. Results Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10, non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35 and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16. An analysis of the previous published meta-analysis strongly suggested the presence of publication bias. Conclusions There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.

  2. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated the...

  3. Severe thrombocytopenia induced by iodinated contrast after coronary angiography: The use of gadolinium contrast and intravascular ultrasound as an alternative to guide percutaneous coronary intervention.

    Science.gov (United States)

    Cubero-Gómez, José María; Guerrero Márquez, Francisco J; Diaz-de la-Llera, Luis; Fernández-Quero, Mónica; Guisado-Rasco, Agustín; Villa-Gil-Ortega, Manuel

    2017-01-01

    Acute contrast-induced thrombocytopenia is a rare event with the use of modern low osmolarity iodinated contrast media. The pathophysiological mechanism that causes platelet counts to drop has not been identified, but an immunological mechanism is suspected due to cytotoxicity after previous exposure to contrast. We report the case of a 47-year-old male patient with acute severe thrombocytopenia due to iodinated contrast media exposure. His platelet count after the procedure with the highest amount of contrast was zero, which is the lowest reported platelet count to date. Percutaneous coronary revascularization under both intravascular ultrasound and gadolinium contrast guidance was performed without complications. The most feared complication after the use of gadolinium is nephrogenic systemic fibrosis, especially in patients on hemodialysis. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Controlled antegrade intimal tracking with subintimal balloon inflation as a novel bailout technique for chronic total occlusion after failed intravascular ultrasound-guided parallel wire technique.

    Science.gov (United States)

    Imai, Yuta; Yajima, Junji; Hosaka, Fumitaka

    Failure to cross with a guidewire is the most common reason for failure of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). In cases of CTO PCI with no interventional collaterals, an intravascular ultrasound (IVUS)-guided parallel wire technique is usually the last-resort procedure. Failure of this technique sometimes causes enlarged subintimal space, resulting in procedure failure. We present a successful second attempt at left anterior descending artery CTO PCI with no interventional collaterals. After IVUS-guided parallel wire technique failed with an enlarged subintimal space, successful antegrade wire crossing was achieved using controlled antegrade intimal tracking with balloon inflation in the subintimal space to deflect a second wire. This technique may be useful as a bailout strategy in otherwise-failed CTO PCI with an enlarged subintimal space. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis.

    Science.gov (United States)

    Nerlekar, Nitesh; Cheshire, Caitlin J; Verma, Kunal P; Ihdayhid, Abdul-Rahman; McCormick, Liam M; Cameron, James D; Bennett, Martin R; Malaiapan, Yuvaraj; Meredith, Ian T; Brown, Adam J

    2017-01-20

    Our aim was to assess whether intravascular ultrasound (IVUS) improves clinical outcomes during implantation of first- and second-generation drug-eluting stents (DES). IVUS guidance is associated with improved clinical outcomes during DES implantation, but it is unknown whether this benefit is limited to either first- or second-generation devices. MEDLINE, EMBASE and PubMed were searched for studies comparing outcomes between IVUS- and angiography-guided PCI. Among 909 potentially relevant studies, 15 trials met the inclusion criteria. The primary endpoint was MACE, defined as death, myocardial infarction, target vessel/lesion revascularisation (TVR/TLR) or stent thrombosis (ST). Summary estimates were obtained using Peto modelling. In total, 9,313 patients from six randomised trials and nine observational studies were included. First-generation DES were implanted in 6,156 patients (3,064 IVUS-guided and 3,092 angiography-guided) and second-generation in 3,157 patients (1,528 IVUS-guided and 1,629 angiography-guided). IVUS guidance was associated with a significant reduction in MACE (odds ratio [OR] 0.73, 95% CI: 0.64-0.85, pDES (0.57, 95% CI: 0.43-0.77, pDES, IVUS guidance was associated with significantly lower rates of cardiac death (OR 0.33, 95% CI: 0.14-0.78, p=0.02), TVR (OR 0.47, 95% CI: 0.28-0.79, p=0.006), TLR (OR 0.61, 95% CI: 0.42-0.90, p=0.01) and ST (OR 0.31, 95% CI: 0.12-0.78, p=0.02). Cumulative meta-analysis highlighted progressive temporal benefit towards IVUS-guided PCI to reduce MACE (OR 0.60, 95% CI: 0.48-0.75, pDES platforms. These data support the use of IVUS guidance in contemporary revascularisation procedures using second-generation DES.

  6. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  7. The use of intravascular ultrasound imaging to improve use of inferior vena cava filters in a high-risk bariatric population.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Bogey, William M; Parker, Frank M; Powell, Steve

    2007-12-01

    Pulmonary embolism is the leading cause of death after gastric bypass procedures for obesity, approximating 0.5% to 4%. All bariatric patients, but especially the super-obese, which have a body mass index (BMI) >50 kg/m(2), are at significant risk for postoperative venous thromboembolism (VTE). Visualization and weight limitations of fluoroscopy tables exclude most bariatric and all super-obese patients from inferior vena cava (IVC) filter placement using fluoroscopy. Intravascular ultrasound (IVUS)-guided IVC filter placement is the only modality that allows these high-risk patients to have an IVC filter placed. Hospital and outpatient records of the 494 patients who underwent gastric bypass procedures from January 1, 2004, to May 31, 2006, were reviewed. All patients who had concurrent IVC filter placement with the use of IVUS guidance were selected. Comorbidities, outcomes, and complications were recorded. We identified 27 patients with mean BMI of 70 +/- 3 kg/m(2); of these, 25 were super-obese (BMI >50 kg/m(2)). Procedures included five laparoscopic and 22 open gastric bypass operations. All patients underwent concurrent IVC filter placement using IVUS guidance. In addition to super-obesity, indications for IVC filter placement included history of VTE (n = 4), known hypercoagulable state (n = 2), and profound immobility (n = 21). Mean follow up was 293 +/- 40 days. Technical success rate was 96.3%. There were no catheter site complications. In one surviving patient, a nonfatal pulmonary embolism was detected by computed tomography 2 months postoperatively. Two patients died, and autopsy excluded VTE as the cause of death in both. This study suggests efficacy of IVUS-guided IVC filter placement in preventing mortality from pulmonary embolism in high-risk bariatric patients, including the super-obese. IVUS-guided IVC filter placement can be safely performed with an excellent success rate in all bariatric patients, including the super-obese, who otherwise would

  8. Acute myocardial infarction due to spontaneous, localized, acute dissection of the sinus of Valsalva detected by intravascular ultrasound and electrocardiogram-gated computed tomography.

    Science.gov (United States)

    Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki

    2016-09-01

    A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.

  9. Comprehensive analysis of intravascular ultrasound and angiographic morphology of culprit lesions between ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome.

    Science.gov (United States)

    Takaoka, Naoko; Tsujita, Kenichi; Kaikita, Koichi; Hokimoto, Seiji; Mizobe, Michio; Nagano, Masahide; Horio, Eiji; Sato, Koji; Nakayama, Naoki; Yoshimura, Hiromi; Yamanaga, Kenshi; Komura, Naohiro; Kojima, Sunao; Tayama, Shinji; Nakamura, Sunao; Ogawa, Hisao

    2014-02-15

    Some plaques lead to ST-segment elevation myocardial infarction (STEMI), whereas others cause non-ST-segment elevation acute coronary syndrome (NSTEACS). We used angiography and intravascular ultrasound (IVUS) to investigate the difference of culprit lesion morphologies in ACS. Consecutive 158 ACS patients whose culprit lesions were imaged by preintervention IVUS were enrolled (STEMI=81; NSTEACS=77). IVUS and angiographic findings of the culprit lesions, and clinical characteristics were compared between the groups. There were no significant differences in patients' characteristics except for lower rate of statin use in patients with STEMI (20% vs 44%, p=0.001). Although angiographic complex culprit morphology (Ambrose classification) and thrombus were more common in STEMI than in NSTEACS (84% vs 62%, p=0.002; 51% vs 5%, pSYNTAX score was lower in STEMI (8.6 ± 5.4 vs 11.5 ± 7.1, p=0.01). In patients with STEMI, culprit echogenicity was more hypoechoic (64% vs 40%, p=0.01), and the incidence of plaque rupture, attenuation and "microcalcification" were significantly higher (56% vs 17%, pMorphological feature (outward vessel remodeling, plaque buildup and IVUS vulnerability of culprit lesions) might relate to clinical presentation in patients with ACS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Ultrasound thrombolysis in stent thrombosis.

    Science.gov (United States)

    Rassin, T; Desmet, W; Piessens, J; Rosenschein, U

    2000-11-01

    Recent refinement in stent implantation technique and peri-procedural pharmacological treatment has lowered the incidence of stent thrombosis significantly. Still, all stent thromboses are associated with major adverse events. In previous studies it has been suggested that intravascular ultrasound fibrinolysis is safe and effective. In this report, ultrasound successfully reperfused thrombotically occluded stents. These observations suggest that ultrasound may dissolve occlusive platelet-rich thrombus effectively and safely. Cathet. Cardiovasc. Intervent. 51:332-334, 2000. Copyright 2000 Wiley-Liss, Inc.

  11. A new method to quantify coronary calcification by intravascular ultrasound - the different patterns of calcification of acute myocardial infarction, unstable angina pectoris and stable angina pectoris.

    Science.gov (United States)

    Wang, Xiaofei; Lu, Chengzhi; Chen, Xin; Zhao, Xiangdong; Xia, Dasheng

    2008-11-01

    Intravascular ultrasound (IVUS) enables the identification of calcification with more details and quantification of calcification, but there is not a proper method to quantify the calcification with IVUS. Previous IVUS studies used arc or length of calcium, respectively, to quantify calcification, but calcium is determined by a combination of arc and length. We devised a new method to quantify calcium as arc area (AA) in the present study, and AA is two-dimensional and irrelevant to vessel size. We selected 201 patients with stable angina pectoris (SAP), unstable angina pectoris (UAP), or acute myocardial infarction (AMI) who underwent IVUS imaging of a de novo native atherosclerotic lesion considered to be the culprit lesion before percutaneous coronary intervention between December 2001 and December 2007. The culprit lesion site for analysis was the 10 mm-long segment including the smallest lumen cross-sectional area. The arc of each calcium deposit in each image was measured with a protractor centered on the lumen and the length of each calcium deposit was calculated with the number of images containing the calcium deposit minus 1, then multiplying 0.5 mm (the images were 0.5 mm apart). Finally, the AA was calculated by arc (degree) multiplying length (mm). The average number of calcium deposits in the culprit lesions of patients with acute myocardial infarction (AMI) was significantly larger than patients with SAP or UAP, and the number of calcium deposits of patients with SAP or UAP was almost the same (mean +/- SD, AMI 2.21 +/- 1.98, SAP 1.15 +/- 1.01, UAP 1.20 +/- 1.15, AMI versus SAP or UAP; p < 0.0005). The average AA per calcium deposit was significantly different in culprit lesions of patients with SAP and UAP or AMI, the calcium deposits were bigger in SAP than in UAP or AMI, and there were no differences between UAP and AMI (mean +/- SD, SAP 788.6 +/- 767.0 degree x mm, UAP 136.6 +/- 189.3 degree x mm, AMI 148.4 +/- 217.1 degree x mm, SAP versus UAP or

  12. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  13. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  14. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials.

    Science.gov (United States)

    Bavishi, Chirag; Sardar, Partha; Chatterjee, Saurav; Khan, Abdur Rahman; Shah, Arpit; Ather, Sameer; Lemos, Pedro A; Moreno, Pedro; Stone, Gregg W

    2017-03-01

    The relative outcomes of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) compared with angiography-guided PCI with drug-eluting stent (DES) in complex lesions have not been established. We sought to compare the efficacy and safety of IVUS-guided PCI with angiography-guided PCI in patients with complex coronary lesions treated with DES. Electronic databases were searched to identify all randomized trials comparing IVUS-guided vs angiography-guided DES implantation. We evaluated major adverse cardiac events (MACE), all-cause and cardiovascular death, myocardial infarction, target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis outcomes at the longest reported follow-up. Random-effects modeling was used to calculate pooled relative risk (RR) and 95% CIs. Eight trials comprising 3,276 patients (1,635 IVUS-guided and 1,641 angiography-guided) enrolling only patients with complex lesions were included. Mean follow-up was 1.4±0.5years. Compared with angiography-guided PCI, patients undergoing IVUS-guided PCI had significantly lower MACE (RR 0.64, 95% CI 0.51-0.80, P=.0001), TLR (RR 0.62, 95% CI 0.45-0.86, P=.004), and TVR (RR 0.60, 95% CI 0.42-0.87, P=.007). There were no significant differences for stent thrombosis, cardiovascular death, or all-cause death. In meta-regression analysis, IVUS-guided PCI was of greatest benefit in reducing MACE in patients with acute coronary syndromes, diabetes, and long lesions. The present meta-analysis demonstrates a significant reduction in MACE, TVR, and TLR with IVUS-guided DES implantation in complex coronary lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The cerebral intravascular enhancement sign is not specific: a contrast-enhanced MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Bakshi, R.; Kinkel, W.R.; Bates, V.E.; Mechtler, L.L.; Kinkel, P.R. [Lucy Dent Imaging Center, University at Buffalo, NY (United States)

    1999-02-01

    The intravascular enhancement (IVE) sign, also known as the ``arterial enhancement sign``, is an abnormal finding in the brain on contrast-enhanced MRI studies. IVE has been described in arterial cerebrovascular disorders, most commonly in acute or subacute arterial ischemic infarcts. However, the specificity of this sign has not been established. We describe four patients with disorders other than arterial strokes in whom gadolinium-enhanced high-field (1.5 T) MRI suggested IVE. The conditions were herpes simplex viral encephalitis, idiopathic cerebellitis, pneumococcal meningitis, and superior sagittal sinus thrombosis with venous infarction. IVE in these cases may be due to multiple factors, including arterial, venous, perivascular, and leptomeningeal or sulcal contrast medium accumulation. Our observations suggest that arterial ischemia, previously described as the cardinal cause of IVE, probably does not explain all instances, and urge caution in interpreting this sign as a specific MRI manifestation of acute arterial infarction or ischemia. (orig.) With 4 figs., 1 tab., 44 refs.

  17. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology.

    Science.gov (United States)

    Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S

    2016-05-01

    Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary

  18. Circulating Microparticles and Coronary Plaque Components Assessed by Virtual Histology Intravascular Ultrasound of the Target Lesion in Patients with Stable Angina.

    Directory of Open Access Journals (Sweden)

    Pil-Ki Min

    Full Text Available High levels of microparticles (MPs circulate in the blood of patients with atherosclerotic diseases where they can serve as potential biomarkers of vascular injury and cardiovascular outcome. We used virtual histology intravascular ultrasound (VH-IVUS to evaluate the relationship between the levels of circulating MPs and the coronary plaque composition in patients with stable angina. We included 35 patients with stable angina (22 men, age 64 ± 9 years and a de novo target lesion. Preintervention gray-scale and VH-IVUS analysis was performed across the target lesion. Volumetric analysis was performed over a 10-mm-long segment centered at the minimum luminal site. Blood samples were obtained from the femoral artery before coronary angioplasty. MPs were measured using a solid-phase capture assay from a commercial kit. We divided participants into either a low MPs group or high MPs group based on the median value of MPs. There was no significant difference in baseline characteristics between the groups. The plaque burden and remodeling index were similar between the groups. The presence of VH-IVUS-derived thin-cap fibroatheroma was not different between the groups. The percentage of the necrotic core (NC was significantly higher in the high MPs group than in the low MPs group, both in planar (17.0 ± 8.8% vs. 24.1 ± 6.9%, p = 0.012 and volumetric analyses (17.0 ± 4.8% vs. 22.1 ± 4.3%, p = 0.002. Circulating MPs were positively correlated with the percentage of the NC area at the minimal luminal site (r = 0.491, p = 0.003 and the percentage of the NC volume (r = 0.496, p = 0.002. Elevated levels of circulating MPs were associated with the amount of NC in the target lesion in those with stable angina, suggesting a potential role of circulating MPs as a biomarker for detecting unstable plaque in patients with stable angina.

  19. Application of Near Infrared Spectroscopy, Intravascular Ultrasound and the Coronary Calcium Score to Predict Adverse Coronary Events

    Science.gov (United States)

    2015-10-01

    patients undergoing Bioflow coronary stent implantation . This will expand our possible screening population. 8 Reportable Outcomes Data...in 2013 and is accruing at a rate of 2-5 per month, usual for a significant risk cardiovascular study. Follow-up is desired for five years. We are

  20. The study of cardiovascular changes by intravascular injection of contrast media

    International Nuclear Information System (INIS)

    Kim, Yang Sook; Park, Chang Yoon

    1986-01-01

    This investigation was aimed to study the effect of contrast media on the cardiovascular system. So in this study, pithed rats were used whether alteration in cardiovascular system by contrast media were controlled centrally. Furthermore, several hypertonic solutions were also used to clarify the effect of contrast media. The results are as follows: 1. Intravenous injection of contrast media in rats (2.5 ml/kg) caused hypotension and bradycardia. The effects were neither blocked by pretreatment of atropine nor pyribenzamine+atropine. 2. NaCI 4.7%, dextrose 24.8%, urea 9.0% and glycerol 10.1% (v/v) which were equiosmolar with contrast media, caused hypotension, but did not affect the heart rate. 3. In pithed rats, intravenous injection of Angiografin increased blood pressure in a dose-dependant manner, and caused decrease in heart rate compared with those of control rats. 4. In pithed rats, bradycardia by intravascular injection with Angiografin was partially blocked by atropine. 5. Metrizamide of which iodine content was adjusted to 280 mg/ml caused increased in blood pressure when was injected intravenously in pithed rats with little effect on heart rate. 6. When perfused with contrast media in rat hindlimb at 15 ml/min./kg speed both perfusion pressure and flow effluent increased, simultaneously. These results suggest that hypotension might be caused by the central effect due to hyperosmolarity of contrast media and bradycardia caused by both parasympathetic stimulation and direct inhibitory action on the cardiac conductive system.

  1. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    DEFF Research Database (Denmark)

    Tearney, Guillermo J; Regar, Evelyn; Akasaka, Takashi

    2012-01-01

    The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the di...... the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease....

  2. Intravascular photoacoustic tomography for characterization of atherosclerotic lipid and inflammation

    Science.gov (United States)

    Zhang, Jian; Qin, Huan; Shi, Yujiao; Yang, Sihua; Xing, Da

    2014-09-01

    Photoacoustic imaging is a fast growing imaging technology depending on its high optical resolution of optics while taking the advantage of the high penetration depth of ultrasound. In this paper, we demonstrate the new progress in the photoacoustic imaging. Atherosclerosis is characterized by a progressive build-up of lipid in the arterial wall, which is known as plaque. Histological studies demonstrate that the primary cause of acute cardiovascular events is the rupture of atherosclerotic plaques. Lipid and inflammation within the plaque are related to influence the propensity of plaques to disrupt. Photoacoustic intravascular tomography (IVPAT) holds a great advantage in providing comprehensive morphological and functional information of plaques. Lipid relative concentration maps of atherosclerotic aorta were obtained and compared with histology. Furthermore, by selectively targeting the intravascular inflammatory cytokines, IVPAT is also capable of mapping the inflamed area and determining the degree of inflammation.

  3. Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients.

    Science.gov (United States)

    Shin, Dong-Ho; Hong, Sung-Jin; Mintz, Gary S; Kim, Jung-Sun; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2016-11-14

    The aim of this study was to evaluate the clinical usefulness of intravascular ultrasound (IVUS)-guided new-generation drug-eluting stent (DES) implantation using a meta-analysis of individual patient-level data from randomized trials. Published randomized trials that compare IVUS-guided versus angiography-guided new-generation DES implantation are scarce. Searches of the MEDLINE, Embase, and Cochrane databases were performed to find randomized trials that compared IVUS-guided versus angiography-guided new-generation DES implantation. A total of 2,345 patients from 3 randomized trials were identified, and all patients were treated for long lesions or chronic total occlusions. Individual patient-level data were obtained. The primary endpoint was a major adverse cardiac event, a composite of cardiac death, myocardial infarction, or stent thrombosis. An intention-to-treat analysis and per protocol analysis were performed. By 1 year post-procedure, major adverse cardiac events had occurred in 0.4% of the patients who underwent IVUS-guided DES implantation versus 1.2% of those who underwent angiography-guided DES implantation (hazard ratio [HR]: 0.36; 95% confidence interval [CI]: 0.13 to 0.99; p = 0.040). For the IVUS-guided group, favorable clinical outcomes were observed for myocardial infarction (0% vs. 0.4%; HR: 0.09; p = 0.026). In addition, the clinical benefit of IVUS guidance was stronger in the per protocol analysis (HR: 0.32; 95% CI: 0.12 to 0.89; p = 0.021). Compared with angiographic guidance, IVUS-guided new-generation DES implantation was associated with favorable outcomes in terms of major adverse cardiac events, the composite of cardiac death, myocardial infarction, or stent thrombosis. These findings must be interpreted only for complex lesions, because all identified patients had long lesions or chronic total occlusions. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Incompatibility of water soluble contrast media and intravascular pharmacologic agents: experimental study

    International Nuclear Information System (INIS)

    Lee, Ho Kyu; Kim, Seung Hyup; Kim, Sung Jin; Lee, Young Suk; Kim, Chu Wan; Han, Man Chung

    1991-01-01

    With the development of low osmolar and nonionic contrast media in clinical practice, radiologists have enjoyed increased clinical application along with other advantages such as improvement of patient comfort and safety. Recently, radiologists have introduced many intravascular pharmacologic agents to improve diagnostic quality and patient safety. Shortly after the introduction of these agents, however, it was observed that a precipitate results when a certain pharmacologic agent is mixed with a low osmolar contrast media. These observations have prompted testing of several other drugs used for incompatibility with contrast media. To verify these reports and to investigate other medications not previously tested, the authors analyzed mixtures of contrast agents and medications in vitro and observed them for visible precipitates after operating the high-speed centrifuge. The results were as fallows: The contrast media that produced incompatibilities with some pharmacologic agents were ioxaglate, diatrizote, and iothalamate in the order of frequency. The contrast media that produced no precipitate were iopromide and ioxithalamate. The pharmacologic agents that produced precipitate with some contrast media were Papaverine, Benadryl, Protamine, Cimetidine, Regitin, and Gentamicin. Therefore, we recommend that caution should be taken to recognize incompatibilities and avoid them when intravascular pharmacologic agents of any kind may be incompatible

  5. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...... was relatively good. The conclusion is that IVUS seems to be superior to single-plane arteriography in predicting hemodynamically significant stenoses as defined by duplex scanning....

  6. Discriminant validity study of Achilles enthesis ultrasound.

    Science.gov (United States)

    Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio

    2016-01-01

    We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  7. Factors influencing nurses' decision-making process on leaving in the peripheral intravascular catheter after 96 hours: a longitudinal study.

    Science.gov (United States)

    Palese, Alvisa; Cassone, Andrea; Kulla, Annamaria; Dorigo, Sabrina; Magee, Jesse; Artico, Marco; Camero, Francesco; Cassin, Catia; Cialdella, Sandra; Floridia, Giuseppe; Nadlišek, Boris; Palcic, Annamaria; Valle, Giulia; Sclauzero, Paola

    2011-01-01

    The clinical and research debate on the peripheral intravascular (PIV) catheter length of stay in situ is ongoing. The principal aim of this study was to explore the factors behind a nurse's decision to leave a PIV in place for more than 96 hours. The study focused on 7 northern Italian hospitals in 2009. A consequent sample of 269 PIV catheters was included. Direct observation and interviews were adopted. The time of the expected PIV replacement was fixed at 96 hours after its positioning, in accordance with the international guideline. Several factors were taken into account in regard to replacement of the PIV catheters by nurses, ranging from analysis based on their own clinical experience with PIV complications and analysis of the patient's clinical situation to the critical analysis of their own work situation. This clinical decision-making process is valuable: leaving the PIV in place for more than 96 hours is a complex decision and not simply a guideline violation.

  8. Endovascular cooling versus standard femoral catheters and intravascular complications: A propensity-matched cohort study.

    Science.gov (United States)

    Andremont, Olivier; du Cheyron, Damien; Terzi, Nicolas; Daubin, Cedric; Seguin, Amélie; Valette, Xavier; Lecoq, Flore-Anne; Parienti, Jean-Jacques; Sauneuf, Bertrand

    2018-03-01

    Targeted temperature management (TTM) contributes to improved neurological outcome in adults who have been successfully resuscitated after cardiac arrest with shockable rhythm. Endovascular cooling catheters are widely used to induce and maintain targeted temperature in the ICU. The aim of the study was to compare the risk of complications with cooling catheters and standard central venous catheters. In this prospective single-centre cohort study, we included all patients admitted to an intensive care unit for successfully resuscitated cardiac arrest that required endovascular TTM (Coolgard ® , Zoll™ Medical corporation, MA, USA), between August 2012 and November 2014, inclusive. We matched the endovascular cooling catheter cohort with a retrospective historical cohort of 512 central femoral venous catheters from the 3SITES trial to compare thrombotic and infectious complications. Overall, 108 patients were included in the cooling cohort, of which 89 had ultrasound doppler. The duration of catheterization was 4.9 days in the control group versus 4.2 days in the TTM group (p = 0.08). After propensity-score matching, there were significantly more thrombotic complications in the cooling (n = 75) than in the control (n = 75) group (12 of 75 (16%) versus 0 of 75 (0%), respectively, p = 0.005), and 4 patients presented major complications. There were 8 colonized catheters in each group (11%) (p > 0.99), and none of the patients had a catheter-related bloodstream infection. In our propensity-score matched study, endovascular cooling catheters were associated with an increased risk of venous catheter-related thrombosis compared to standard central venous catheters. Copyright © 2017. Published by Elsevier B.V.

  9. Jaundice: a preliminary study with the ultrasound

    International Nuclear Information System (INIS)

    Chen Xiang; Sun Jian; Liu Haiping; Luo Weiquan

    2006-01-01

    Objective: To evaluate the ultrasound in imaging diagnosis of jaundice. Methods: The changes of ultrasonography of 116 patients with jaundice were correlatively studied with the final diagnosis. Results: Hepatocellular jaundice was found in 27 cases out of 116; and obstructive jaundice was revealed in other 89 cases. The level of obstruction was correctly assessed by ultrasound in 94.2% of the patients. The primary lesion was successfully identified by ultrasound in 87.6% cases of obstructive jaundice. Misdiagnosis was made in 8 cases. Conclusion: Ultrasonography can confirm the obstructive jaundice. The level of obstruction can be precisely located and the primary lesions can be correctly identified in most cases. Better understanding the sonographic characteristics of benign disorder such as inflam-matory mass of caput of pancreas and inflammatory stricture of common bile duct results in a higher diagnostic accuracy. (authors)

  10. Characterization and morphology of atherosclerotic plaque of coronary arteries: utility of electron-beam tomography to detect non-calcified plaque: a comparison with conventional coronary angiography and intravascular ultrasound.

    Science.gov (United States)

    Funabashi, Nobusada; Misumi, Kazuo; Ohnishi, Hiroyuki; Asano, Miki; Komuro, Issei

    2007-01-31

    Electron-beam tomography (EBT) may provide useful information about characterization and morphology of atherosclerotic plaque of coronary arteries. Twenty-six subjects (20 male, 6 female) with suspected coronary heart disease had two routine (r) and one enhanced (e) EBT scans to detect non-calcified plaque (NCP) in the coronary arterial lumen, and were compared with conventional coronary angiograms (CAG) and intravascular ultrasound (IVUS). Three had the sites, which did not have high CT values suggesting calcification in rEBT, nor which was not enhanced by contrast material in eEBT. One had the site with positive CT values that were supposed to be the proliferation intima or organized thrombus and at the corresponding site mixed plaque was observed in the IVUS image. The other two had the site with negative CT values that were supposed to be fat tissue with significant stenosis in CAG. We also made the cross-sectional images of the vessel and the morphology of the NCP, which projected into the lumen, could be evaluated. We could detect the NCP, differentiate fat tissue from soft tissue and evaluate the morphology of the plaque in EBT.

  11. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  12. Ultrasound for Drug and Gene Delivery to the Brain

    OpenAIRE

    Hynynen, Kullervo

    2008-01-01

    Noninvasive, transient, and local image-guided blood-brain barrier disruption (BBBD) has been demonstrated with focused ultrasound exposure in animal models. Most studies have combined low pressure amplitude and low time average acoustic power burst sonications with intra-vascular injection of pre-formed micro-bubbles to produce BBBD without damage to the neurons. The BBB has been shown to be healed within a few hours after the exposure. The combination of focused ultrasound beams with MR ima...

  13. Retrospective study of intravascular large B-cell lymphoma cases diagnosed in Quebec: A retrospective study of 29 case reports.

    Science.gov (United States)

    Brunet, Vanessa; Marouan, Sofia; Routy, Jean-Pierre; Hashem, Mohamed Amin; Bernier, Vincent; Simard, Raynald; Petrella, Tony; Lamarre, Louis; Théorêt, Gilles; Carrier, Christian; Knecht, Hans; Fleury, Isabelle; Pavic, Michel

    2017-02-01

    Intravascular large B-cell lymphoma (IVL) is an extremely rare malignancy, mainly studied through European and Asian series. Due to the low incidence of this condition, our understanding of the clinical presentation as well as the management of IVL relies on a limited number of patients.We report the largest North American study to date on IVL with 29 cases from Quebec hospital diagnosed between 1990 and 2016. The aim of our study is to describe the clinical presentations, diagnostic and staging procedures, therapeutic management and clinical outcomes of IVL patients in our population and compare the disease phenotype to European and Asian series reported.In our cohort, all patients had stage IV IVL at diagnosis, with a median age of 66.7 years (range 47.2-90.8). Clinical presentation was characterized by constitutional symptoms (100%), poor ECOG-PS (100% ≥ 2), cytopenias (93% anemia), and elevated lactate dehydrogenase (97%) and C-reactive protein (96%). Our cohort presented with mainly cutaneous and neurological symptoms. However, neurological involvement (75.9%) was predominant and no "cutaneous variant" was observed; this differs from European literature, where "classical" IVL is reported with mainly cutaneous involvement. Two of our Caucasian patients presented "Asian variant" IVL; this observation is not unusual, as cases of "classical" IVL have been reported in Asians and "Asian variant" IVL has been reported in Europeans. All patients were classified according to their immunophenotypic features in 3 different subgroups (CD5 or CD5CD10, CD5CD10, CD5CD10) with no difference in outcome. Finally, 62% of our cohort received anthracycline-based chemotherapy and 53% of them achieved a complete response. After a median follow-up of 328 days, OS at 3 years was 42.7% for the entire cohort and 47.4% for the cases with in vivo diagnosis. Unlike European studies on "classical" IVL, our study showed that the French Canadian presentation of this subtype of IVL is more

  14. Intravascular photoacoustic imaging of human coronary atherosclerosis

    Science.gov (United States)

    Jansen, Krista; van der Steen, Antonius F. W.; Springeling, Geert; van Beusekom, Heleen M. M.; Oosterhuis, J. Wolter; van Soest, Gijs

    2011-03-01

    We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. We specifically imaged lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction. An integrated intravascular photoacoustics (IVPA) and ultrasound (IVUS) catheter with an outer diameter of 1.25 mm was developed. The catheter comprises an angle-polished optical fiber adjacent to a 30 MHz single-element transducer. The ultrasonic transducer was optically isolated to eliminate artifacts in the PA image. We performed measurements on a cylindrical vessel phantom and isolated point targets to demonstrate its imaging performance. Axial and lateral point spread function widths were 110 μm and 550 μm, respectively, for PA and 89 μm and 420 μm for US. We imaged two fresh human coronary arteries, showing different stages of disease, ex vivo. Specific photoacoustic imaging of lipid content, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm.

  15. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  16. No change in impedance upon intravascular injection of D5W.

    Science.gov (United States)

    Chin, James; Tsui, Ban C H

    2010-06-01

    Electrical impedance increases following test injections of non-conducting solutions around nerves; however, this increase should diminish rapidly with intravascular needle placement, wherein the systemic circulation will dissipate the solution. For this observational study, we hypothesized that the impedance increases significantly at the perineural space after an injection of 5% dextrose in water (D5W), but that it does not increase correspondingly at the intravascular location After Ethics Research Board approval, electrical impedance was measured by a nerve stimulator displaying resistance, Stimuplex HNS 12, before and during (30 sec) an injection of D5W 3 mL: 1) during intravenous cannula placement using an insulated stimulating needle sheathed in its plastic cannula, MultiSet NanoLine with 18G needle; and 2) during needle placement (Pajunk 22G insulated) for an ultrasound-guided supraclavicular block in patients undergoing hand surgery. The impedance changes at each location were analyzed and compared. Data were collected from 16 patients. Baseline impedance was lower intravascularly (mean 16.5 +/- standard deviation 7.2 kOmega) compared with perineurally (23.5 +/- 8.3 kOmega) (P = 0.037). Peak impedance after intravascular D5W injection was 20.1 +/- 6.8 kOmega, which was not a significant change (P = 0.15). In contrast, peak impedance after perineural D5W injection was 58.6 +/- 29.1 kOmega, an increase of 35.1 +/- 26.4 kOmega (155 +/- 117%), and then it reached a plateau of 36.7 +/- 19.6 kOmega. The increase in impedance was significantly greater at the perineural location (P < 0.0001). The absence of a significant increase in impedance upon injection of D5W prior to injection of local anesthetic may provide useful information to warn of intravascular injection.

  17. Intravascular Myopericytoma in the Heel: Case Report and Literature Review

    Science.gov (United States)

    Valero, José; Salcini, José L.; Gordillo, Luis; Gallart, José; González, David; Deus, Javier; Lahoz, Manuel

    2015-01-01

    Abstract Intravascular myopericytoma (IVMP), regarded as a variant of myopericytoma, is a rare tumor. Very few cases have been described, none in the foot. The first case of IVMP located in the heel of the foot is described in this article. A literature review is reported of all cases of IVMP published in the English literature. A 48-year-old man possessed an IVMP on the heel of the right foot. The physical examination and histopathological and ultrasound studies are described. The literature review yielded 5 cases of IVMP, 2 of which were in the thigh and 1 each in the oral mucosa, the periorbital region, and the leg. The possibility that these lesions may be malignant suggests that the histopathological study of vascular tumors should include immunohistochemical tests. PMID:25789958

  18. Ultrasound

    Science.gov (United States)

    ... chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. ... by: Jason Levy, MD, Northside Radiology Associates, Atlanta, GA. Also ...

  19. [Intravascular endothelioma (author's transl)].

    Science.gov (United States)

    Vanĕk, J

    1978-01-01

    A 76-year-old woman developed a slowly growing lesion over the right index and the adjacent part of the metacarpus. A cell proliferation filling up the skin veins was classified as intravascular endothelioma. This rather rare oncological entity with a good prognosis should be differentiated from peculiar pattern occasionally seen in organisation of thrombi as well as malignant endothelial tumours.

  20. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  1. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  2. Studies on the use of power ultrasound in leather dyeing.

    Science.gov (United States)

    Sivakumar, Venkatasubramanian; Rao, Paruchuri Gangadhar

    2003-03-01

    Uses of power ultrasound for acceleration/performing the chemical as well as physical processes are gaining importance. In conventional leather processing, the diffusion of chemicals through the pores of the skin/hide is achieved by the mechanical agitation caused by the paddle or drumming action. In this work, the use of power ultrasound in the dyeing of leather has been studied with the aim to improve the exhaustion of dye for a given processing time, to reduce the dyeing time and to improve the quality of dyed leather. The effect of power ultrasound in the dyeing of full chrome cow crust leather in a stationary condition is compared with dyeing in the absence of ultrasound as a control experiment both in a stationary as well as conventional drumming condition. An ultrasonic cleaner (150 W and 33 kHz) was used for the experiments. Actual power dissipated into the system was calculated from the calorimetric measurement. Experiments were carried out with variation in type of dye, amount of dye offer, temperature and time. The results show that there is a significant improvement in the percentage exhaustion of dye due to the presence of ultrasound, when compared to dyeing in absence of ultrasound. Experiments on equilibrium dye uptake carried out with or without ultrasound suggest that ultrasound help to improve the kinetics of leather dyeing. The results indicate that leathers dyed in presence of ultrasound have higher colour values, better dye penetration and fastness properties compared to control leathers. The physical testing results show that strength properties of the dyed leathers are not affected due to the application of ultrasound under the given process conditions. Apparent diffusion coefficient during the initial stage of dyeing process, both in presence and in absence of ultrasound was calculated. The values show that ultrasound helps in improving the apparent diffusion coefficient more for the difficult dyeing conditions such as in the case of metal

  3. Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up

    NARCIS (Netherlands)

    M. Degertekin (Muzaffer); J.J. Popma (Jeffrey); K. Tanabe (Kengo); J. Vos (Jeroen); M.J.B.M. van den Brand (Marcel); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); D.P. Foley (David); W.J. van der Giessen (Wim); P.C. Smits (Pieter); E.S. Regar (Eveline)

    2002-01-01

    textabstractBACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the

  4. Determinants of Intravascular Resistance in Indian Diabetic Nephropathy Patients: A Hospital-Based Study

    Directory of Open Access Journals (Sweden)

    Anubhav Thukral

    2011-01-01

    Full Text Available Aims and Objectives. Metabolic dysregulation has failed to explain clinical variability of patients with diabetic nephropathy and hence a renewed interest emerged in haemodynamic factors as determinant of progression and development of diabetic nephropathy. We therefore studied for various factors which can correlate with raised renal vascular resistance in diabetic nephropathy. Material and Methods. Renal vascular resistance was measured in patients with established and incipient diabetic nephropathy and compared with controls using noninvasive color Doppler examinations of intrarenal vasculature. Results. Renal vascular resistance correlated with age, duration of disease, GFR, serum creatinine, and stage of retinopathy. Renal vascular resistance was significantly reduced in patients on treatment with RAAS inhibitors and insulin, than those on OHA and antihypertensives other than RAAS inhibitors. Conclusion. The study implies that renal vascular resistance may help identify diabetics at high risk of developing nephropathy, and these set of patients could be candidates for RAAS inhibition and early insulin therapy even in patients without albuminuria.

  5. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  6. A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements

    International Nuclear Information System (INIS)

    Have, A G ten; Gijsen, F J H; Wentzel, J J; Slager, C J; Serruys, P W; Steen, A F W van der

    2006-01-01

    Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its heat production were varied. Concerning the heat transfer, the thermal properties of the lipid core and the location of the vasa vasorum were studied. The heat source location was the main determinant of the lumen wall temperature distribution. The strongest effect was noted when the heat producing macrophages were located in the shoulder region leading to focal spots of higher temperature. The maximal lumen wall temperature was mainly determined by the heat production of the macrophages and the cooling effect of blood. The insulating properties of the lipid core increased lumen wall temperatures when the heat source was located in the cap and the presence of vasa vasorum lowered the temperatures. These results show that the lumen wall temperature distribution is influenced by vulnerable plaque composition and that intracoronary thermography techniques require a high spatial resolution. To be able to couple temperature measurements to plaque vulnerability, intracoronary thermography needs to be combined with an imaging modality

  7. Impaired intravascular triglyceride lipolysis constitutes a marker of clinical outcome in patients with stable angina undergoing secondary prevention treatment: a long-term follow-up study.

    Science.gov (United States)

    Sposito, Andrei C; Lemos, Pedro A; Santos, Raul D; Hueb, Whady; Vinagre, Carmen G C; Quintella, Edgard; Carneiro, Otavio; Chapman, M John; Ramires, Jose A F; Maranhão, Raul C

    2004-06-16

    We sought to verify whether the intravascular metabolism of chylomicron-like emulsion may predict the clinical evolution of patients with coronary artery disease (CAD) undergoing secondary prevention therapy of CAD. Case-control studies have suggested an association between impaired intravascular catabolism of triglyceride (TG)-rich lipoproteins and CAD. However, evidence is lacking with respect to the potential clinical relevance of this metabolic disorder in CAD patients. During a period of 4.5 +/- 0.9 years, we followed up 63 stable CAD patients (mean age 60 +/- 10 years) undergoing secondary prevention therapy (low-density lipoprotein cholesterol <100 mg/dl) in whom kinetic studies of the in vivo catabolism of chylomicron-like emulsions were performed. At enrollment into the study, fasting patients were injected intravenously with a chylomicron-like emulsion labeled with radioactive triglyceride (3H-TG) and cholesteryl esters (14C-CE) to evaluate the efficacy of intravascular TG lipolysis. At baseline, CAD patients displayed a diminished fractional clearance rate (FCR) for 3H-TG (-26%; p = 0.027), for 14C-CE (-37%; p = 0.015), and for delipidation index (DI) (-26%; p = 0.02) as compared with 35 control subjects. During follow-up of secondary prevention therapy, 33% of CAD patients (n = 21) presented with clinically refractory angina and aggravated coronary angiographic severity. The FCR for 3H-TG (-44%; p = 0.005) and DI (-41%; p = 0.006) in those patients with refractory angina was significantly lower than that observed in those with stable evolution. Moreover, in a Cox multivariate regression analysis, the presence of a DI less than the median value was an independent predictor of an unfavorable clinical evolution (adjusted hazard ratio 3.32; 95% confidence interval 1.21 to 9.14; p = 0.020). The current study establishes that delayed intravascular TG lipolysis is a strong and independent predictor of evolution to severe angina among patients undergoing

  8. Ability of combined Near-Infrared Spectroscopy-Intravascular Ultrasound (NIRS-IVUS) imaging to detect lipid core plaques and estimate cap thickness in human autopsy coronary arteries

    Science.gov (United States)

    Grainger, S. J.; Su, J. L.; Greiner, C. A.; Saybolt, M. D.; Wilensky, R. L.; Raichlen, J. S.; Madden, S. P.; Muller, J. E.

    2016-03-01

    The ability to determine plaque cap thickness during catheterization is thought to be of clinical importance for plaque vulnerability assessment. While methods to compositionally assess cap integrity are in development, a method utilizing currently available tools to measure cap thickness is highly desirable. NIRS-IVUS is a commercially available dual imaging method in current clinical use that may provide cap thickness information to the skilled reader; however, this is as yet unproven. Ten autopsy hearts (n=15 arterial segments) were scanned with the multimodality NIRS-IVUS catheter (TVC Imaging System, Infraredx, Inc.) to identify lipid core plaques (LCPs). Skilled readers made predictions of cap thickness over regions of chemogram LCP, using NIRS-IVUS. Artery segments were perfusion fixed and cut into 2 mm serial blocks. Thin sections stained with Movat's pentachrome were analyzed for cap thickness at LCP regions. Block level predictions were compared to histology, as classified by a blinded pathologist. Within 15 arterial segments, 117 chemogram blocks were found by NIRS to contain LCP. Utilizing NIRSIVUS, chemogram blocks were divided into 4 categories: thin capped fibroatheromas (TCFA), thick capped fibroatheromas (ThCFA), pathological intimal thickening (PIT)/lipid pool (no defined cap), and calcified/unable to determine cap thickness. Sensitivities/specificities for thin cap fibroatheromas, thick cap fibroatheromas, and PIT/lipid pools were 0.54/0.99, 0.68/0.88, and 0.80/0.97, respectively. The overall accuracy rate was 70.1% (including 22 blocks unable to predict, p = 0.075). In the absence of calcium, NIRS-IVUS imaging provided predictions of cap thickness over LCP with moderate accuracy. The ability of this multimodality imaging method to identify vulnerable coronary plaques requires further assessment in both larger autopsy studies, and clinical studies in patients undergoing NIRS-IVUS imaging.

  9. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  10. Intravascular ultrasound: validation and clinical application

    NARCIS (Netherlands)

    A. van der Lugt (Aad)

    1996-01-01

    textabstractAtherogenesis is a process with an insidious onset and course. Once clinical signs and symptoms have become manifest, the obstructive lesion is usually at an advanced stage. Arteriography is the standard method for evaluation of atherosclerotic disease and has been useful in

  11. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  12. STUDY OF ULTRASOUND FINDING IN DENGUE FEVER

    Directory of Open Access Journals (Sweden)

    Sunita Bajaj

    2016-10-01

    Full Text Available BACKGROUND Dengue fever (DF is a viral haemorrhagic fever causing severe morbidity and mortality in affected patients. The aim of the study is to describe the role of ultrasonography (USG in the assessment of patients with Dengue fever, and its complications and to prove ultrasound is useful in the diagnosis during an epidemic. MATERIALS AND METHODS It is a prospective study was conducted in 2016 comprising of 178 patients who were serologically positive for dengue, radiological investigations were conducted in all cases. RESULTS Out of 178 patients Males (N=117 are more effected subjects in the study. female: Male ratio is 1:2. Hepatomegaly 74.1% which is most common findings in study, 113 (63.4% had GB wall thickening 98 had ascites (55%, 32 had pleural effusion (17.9%. most commonly seen in the age group of 20-39 years. Hepatomegaly was the most common finding noted in 67 patients (37.6%, followed by GB wall thickening in 65 patients (36.1%. Hepatomegaly was more common in 0-19 is 56 patients with 31.4% years age group Ascites in >40 years age group (16.8%. Hepatomegaly was seen in most of the patients whose platelet count was <40,000. (94.7%. GB wall thickening (88.5% common findings seen in patients whose platelet count was <40,000. In patients with platelet count of 40,000-80,000, Ascites is most common finding (87.5%, followed by Splenomegaly (60.7%. In patients whose platelet count was 80,000-150,000, Ascites (50% was more common than Splenomegaly (45.8%. In three patients with platelet count more than 150,000, no sonological abnormality was detected. CONCLUSIONS Ultrasound findings of hepatic changes, GB wall oedema, splenomegaly, ascites and pleural effusion in patients presenting with signs and symptoms of Dengue fever during an epidemic are diagnostic. Contributing in the differential diagnosis with other causes of febrile disease.

  13. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  14. Anesthesia management with ultrasound-guided thoracic paravertebral block for donor nephrectomy: A prospective randomized study.

    Science.gov (United States)

    Yenidünya, Ozlem; Bircan, Huseyin Yuce; Altun, Dilek; Caymaz, Ismail; Demirag, Alp; Turkoz, Ayda

    2017-02-01

    To determine the efficacy of ultrasound-guided thoracic paravertebral block intraoperatively and 24 hours postoperatively in patients undergoing donor nephrectomy. Prospective randomized controlled study. Private foundation university hospital; November 2014 to June 2015. Thirty-two patients undergoing donor nephrectomy (exclusion criteria: coagulation disorders, allergy to local anesthetics, and unwillingness to participate). The final study population comprised 30 patients (15 male, 15 female) randomly assigned to either Group P (paravertebral block, n=14) or Group M (morphine, n=16). In Group P, a unilateral paravertebral catheter was inserted 1 day preoperatively; on the day of surgery, a single-level unilateral paravertebral block was administered through the catheter before general anesthesia. Infusion of bupivacaine continued intraoperatively and postoperatively. Patients in Group M received only general anesthesia, and morphine patient-controlled analgesia was begun postoperatively. Intraoperative analgesic and anesthetic requirement, postoperative numerical rating scale pain scores, additional analgesic consumption during the postoperative period, and incidence of complications related to thoracic paravertebral block (TPVB) like pleural puncture, pneumothorax, epidural spread, injection into the subarachnoid space, intravascular injection, and Horner's syndrome and rate of opioid related adverse reactions like nausea and vomiting, itching, constipation, and respiratory depression. Intraoperative remifentanil consumption was significantly higher in Group M, and postoperative morphine consumption was significantly lower in Group P (P<.001). During the first 24 hours postoperatively, the mean numerical rating scale pain scores were similar and there were no significant differences between the 2 groups. There were no statistically significant differences in the additional analgesic consumption and rate of adverse reactions between the 2 groups. We didn

  15. Disseminated intravascular coagulation in sepsis

    NARCIS (Netherlands)

    Zeerleder, Sacha; Hack, C. Erik; Wuillemin, Walter A.

    2005-01-01

    Disseminated intravascular coagulation is a frequent complication of sepsis. Coagulation activation, inhibition of fibrinolysis, and consumption of coagulation inhibitors lead to a procoagulant state resulting in inadequate fibrin removal and fibrin deposition in the microvasculature. As a

  16. Hypothesis: Disseminated Intravascular Inflammation as the Inflammatory Counterpart to Disseminated Intravascular Coagulation

    Science.gov (United States)

    Bull, Brian S.; Bull, Maureen H.

    1994-08-01

    We have identified a leukocyte activation syndrome that is occasionally associated with the transfusion of intraoperatively recovered erythrocytes. This syndrome appears to result from intravascular damage caused by leukocytes activated during the erythrocyte salvage process. We hypothesize that this syndrome is part of a larger disease grouping: disseminated intravascular inflammation (DII). DII is the analog of the coagulation disorder disseminated intravascular coagulation. In disseminated intravascular coagulation, the organ damage results from uncontrolled activation of the clotting pathway; in DII the damage is caused by leukocytes that have become activated by direct contact with bacteria or in rare instances-such as erythrocyte salvage-in the absence of bacteria and bacterial products. Recent studies of the hazards associated with intraoperative blood salvage indicate that activation of leukocytes can be achieved by exposure to activated platelets alone. If such activated leukocytes are reinfused along with the washed erythrocytes, widespread organ damage may result. The lung is the organ most severely affected by activated leukocytes. Adult respiratory distress syndrome is one outcome. It is likely that DII is a presently unrecognized pathophysiological process that complicates a variety of primary disease states and increases their lethality.

  17. Dosimetric calculus in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho; Stabin, Michael Gregory [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear

    2000-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Two stent sources employing {sup 32}P are also simulated. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  18. Study of Ultrasound Imaging Technique for Diagnosing Osteoporosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H. J.; Han, S. M. [Kyunghee University, Seoul (Korea, Republic of); Lee, J. H.; Lee, M. R. [Pusan National University, Busan (Korea, Republic of)

    2002-08-15

    Ultrasonic has been proposed as an attractive means of detecting bone loss. There have been several commercial ultrasound devices developed for measuring the heel to predict fracture at other bones. However, these devices select only single point of heel bone as measurement site. It causes poor assessment of bone quality due to the error of transducer positioning. In an effort to improve current ultrasound systems, we evaluated the linear scanning method which provides better prediction of bone quality and an accurate image of bone shape. The system used in this study biaxially scans a heel bone using automated linear scanning technique. The results demonstrated that the values of ultrasound parameters varied with different positions within bone specimen. It has been also found that the linear scanning method could better predict bone quality, eliminating the error of transducer positioning

  19. Comparative ultrasound study of acute lateral ankle ligament ...

    African Journals Online (AJOL)

    The purpose of this study was to establish the difference in rehabilitation outcomes between the Jump Stretch Flex Band (JSFB) programme and conventional ankle rehabilitation programmes of acute lateral ankle ligament injuries. This study compares the process of healing under the guidance of ultrasound in both groups.

  20. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Intravascular blood coagulation after irradiation

    International Nuclear Information System (INIS)

    Sushkevich, G.N.

    1981-01-01

    The problems of activation of intravascular blood coagulation (JVBC) at different stages after irradiation, are considered. JVBC peculiarities (disseminated intravascular syndrome (DIV) or thrombo hemorrhagic syndrome) are investigated. Literature on alterations which take place in the organism under effect of ionizing irradiation is analyzed. This analysis proves the characteristic features of thrombinogenesis activation and development of DIV syndrome not only in the early post-radiation period, but in the middle of radiation disease, as well. It is also shown that ionizing radiation activizes the hemocoagulation process and causes IVBC in the case of both local and general irradiation [ru

  2. Ultrasound assisted synthesis of PMMA/clay nanocomposites: Study ...

    Indian Academy of Sciences (India)

    Particle diameter of the nanocomposites was measured by laser diffraction technique. Oxygen permeability of the samples was studied and it was found that the oxygen flow rate was reduced by the combined effect of clay loading and ultrasound. The flame retardant property of the nanocomposites due to clay dispersion ...

  3. Comparison of Ultrasound Cephalometry, Radiology, and Liquor Studies in Patients with Unknown Confinement Dates*

    Science.gov (United States)

    Underhill, Rosemary A.; Beazley, John M.; Campbell, Stuart

    1971-01-01

    The accuracy of predicting fetal maturity by ultrasound cephalometry, radiology, and liquor studies in patients with unknown confinement dates has been compared. The best prediction was given by ultrasound cephalometry. Liquor studies were least helpful. PMID:4106479

  4. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  5. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  6. Ultrasound cylindrical phased array for transoesophageal thermal therapy: initial studies

    Energy Technology Data Exchange (ETDEWEB)

    Melodelima, David [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Lafon, Cyril [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Prat, Frederic [Centre Hospitalier Bicetre, 78 Avenue General Leclerc, 94275 Le Kremlin Bicetre (France); Birer, Alain [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France); Cathignol, Dominique [INSERM, Unite 556, 151 Cours Albert Thomas, 69424 Lyon (France)

    2002-12-07

    This work was undertaken to investigate the feasibility of constructing a cylindrical phased array composed of 64 elements spread around the periphery (OD 10.6 mm) for transoesophageal ultrasound thermotherapy. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were successively excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. For these feasibility studies, we used a cylindrical prototype (OD 10.6 mm) composed of 16 elementary transducers distributed over a quarter of the cylinder, all operating at 4.55 MHz. The active part was mechanically reinforced by a rigid damper structure behind the transducers. It was shown that an ultrasound field similar to that emitted by a plane transducer could be generated. Ex vivo experiments on pig's liver demonstrated that the ultrasound beam could be accurately rotated to generate sector-based lesions to a suitable depth (up to 19 mm). Throughout these experiments, exposures lasting 20 s were delivered at an acoustic intensity of 17 W cm{sup -2}. By varying the power from exposure to exposure, the depth of the lesion at different angles could be controlled.

  7. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  8. Intravascular photoacoustic detection of vulnerable plaque based on constituent selected imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jian; Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2011-01-01

    Atherosclerosis, a disease of the large arteries, is the primary cause of heart disease and stroke. Over decades, atherosclerosis is characterized by thickening of the walls of the arteries, only advanced atherosclerotic disease could be observed. Photoacoustic imaging is a hybrid imaging technique that combines the advantages of high spatial resolution of ultrasound with contrast of optical absorption. In this paper, we present an intravascular photoacoustic (IVPA) imaging system to characterize vulnerable plaques by using the optical absorption contrast between different constituents. Epidemiological studies have revealed several important plaque constituents associated with early atherosclerosis, such as macrophage, cholesterol, lipid, calcification, and so on. We chose a section of lipid rich atherosclerosis artery and a section of normal artery as the phantom. Two IVPA images of them are given to show the difference between sick and normal. As a new method of detecting vulnerable plaque, IVPA constituents imaging will provide more details for diagnosis that offer an enticing prospect in early detecting of atherosclerosis.

  9. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.

    1999-01-01

    . Dose rate calculations are based on the sosimetry formulation of the American Association of Physicists in Medicine, Task Group 43. We apply the technique to optimal planning for intravascular brachytherapy of intimal hyperplasia using ultrasound data and 192Ir seeds. The planning includes...... determination of an optimal dwell-time sequence for a train of seeds that deliver ratiation while stepping through the vessel lesion. The results illustrate the advantage of this strategy over the common approach of delivering radiation by positioning a single train of seeds along the whole lesion....

  10. Model of distribution of dose for intravascular brachytherapy; Modelo de distribucion de dosis para braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, Rosana; Signoretta, Catalina [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Dosimetria de Radioaciones Ionizantes; Martin, Gabriela; Rivera, Elena; Bergoc, Rosa [Univeridad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica. Lab. de Radioisotopos; Guzman, Luis [Instituto Cardiovascular de Buenos Aires (Argentina)

    2001-07-01

    In this work we present the radiation dose distributions for a theoretical model with Monte Carlo simulation, which was based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a {sup 32} P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries. (author)

  11. Extramedullary Hematopoiesis in Uterine Leiomyoma Associated with Numerous Intravascular Thrombi

    Directory of Open Access Journals (Sweden)

    Xiaoyan Cui

    2014-01-01

    Full Text Available We report a case of extramedullary hematopoiesis (EMH in uterine leiomyoma and associated numerous intravascular thrombi. A 29-year-old nulliparous female presented with heavy vaginal bleeding and a hematocrit of 22%. No bone marrow biopsy has been performed. She had a history of uterine leiomyomata and menorrhagia for a year. A transvaginal ultrasound confirmed the presence of a uterine leiomyoma. The patient was treated conservatively with oral contraceptive pills due to desire for fertility. However, she continued to have heavy vaginal bleeding and developed bilateral upper extremity deep vein thrombosis and multiple superficial vein thromboses after two months. An exploratory laparotomy with uterine myomectomy was performed. Gross examination of the specimen revealed a single nodular mass measuring 10.0×9.5×7.5 cm with a white-tan swirling cut surface. Microscopic examination revealed benign smooth muscle consistent with leiomyoma and numerous intravascular thrombi both with areas of EMH. Immunohistochemical stains confirmed the presence of all three benign lineages of hematopoietic cells. Occurrence of EMH in uterine leiomyoma and intravascular thrombi is very rare. It may be related to systemic hematopoietic stimulation due to severe chronic anemia and local presence of hematopoietic growth factors and/or cytokines.

  12. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  13. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  14. Intravascular imaging with a storage phosphor detector

    Science.gov (United States)

    Shikhaliev, Polad M.; Petrek, Peter; Matthews, Kenneth L., II; Fritz, Shannon G.; Bujenovic, L. Steven; Xu, Tong

    2010-05-01

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm3 volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 µCi cm-3 activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm-2 were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360° circumference. Spatial resolution was 0

  15. [Efficiency of ultrasound study in the diagnosis of cholangiocellular carcinoma].

    Science.gov (United States)

    Danzanova, T Iu; Siniukova, G T; Lepédatu, P I; Kudashkin, N E

    2014-01-01

    To evaluate the efficiency of ultrasound diagnosis in detecting and staging cholangiocellular carcinoma. An ultrasound study (USS) was conducted in 120 patients aged 19 to 84 years with cholangiocellular carcinoma. The patients were divided into 3 groups by the location of a tumor process: 1) 47 (39.2%) patients with intrahepatic tumor; 2) 49 (40.8%) with portal duct or Klatskin's tumor; 3) 24 (20%) with distal one. Ninety (75%) patients were operated on; the others underwent minimally invasive X-ray surgical interventions as percutaneous transhepatic cholangiostomies. The data of ultrasound diagnosis were compared with the results of other studies, intraoperative assessment and morphological examination of a removed gross specimen. A tumor was detectable by USS only in 90 (75%) patients; its sensitivity was 100% for intrahepatic cholangiocellular carcinoma; 69.4 and 37.5% for portal duct and distal ones, respectively. It is most difficult to diagnose distal carcinomas of the common bile duct. USS reveals no semiotic signs of intrahepatic cholangiocellular carcinoma, which could distinguish the latter from other liver cancers. The specific features of the infiltrative growth of a bile duct tumor, such as hyperechoic infiltration along the external outlines of the ducts or hypoechoic infiltration during thickening of the duct walls, were ascertained. The sensitivity of intraoperative USS in identifying intrahepatic and portal duct cholangiocarcinoma was 100%. That of USS in detecting lymph node metastases was 61%; developed the semiotics of altered metastatic lymph nodes. The findings have indicated the high informative value of ultrasound diagnosis in determining the dilatation of the bile ducts and the spread of a tumor to the liver and lymph nodes. It is recommended that the indications for intraoperative USS should be expanded in intrahepatic cholangiocellular carcinoma to define the extent of duct carcinoma.

  16. A Preliminary Study on the Possibility of Using Ultrasound in Driver Assistance Systems

    Science.gov (United States)

    Takahashi, Hiroshi; Honda, Hirohiko

    This paper presents a preliminary study on the possibility of using ultrasound in driver assistance systems. Subjects' lap time in a driving video game was measured as an index of their performance of driving operations under acoustic conditions with and without an ultrasound signal at 23kHz, 70dB. The results show that the performance characteristics of the subjects changed when the ultrasound signal was presented. Ultrasound signal tends to concentrate on handling the vehicle and decreasing an attention to check the over speed driving, as a second task. We prove the possibility to apply ultrasound signal to control operator's attention and behavior.

  17. Transrectal ultrasound study of prostatic lithiasis

    International Nuclear Information System (INIS)

    Bock, E.; Calugi, V.; Stolfi, V.; Rossi, P.; D'Ascenzo, R.; Solivetti, F.M.

    1989-01-01

    Prostatic lithiasis is a well know phenomenon. It has little clinical significance and is not easily shown by conventional radiography, which has poor sensitivity and specificity. The authors have studied 612 patients with both suprapubic and transrectal US in order to 1) assess US sensitivity and specificity and 2) report the frequency, spatial distribution, number and features of prostatic calcifications with special emphasis on differential diagnosis between prostatic neoplasms and chronic prostatitis. The authors have also studied the relationship between morphology and symptoms and the results agree with those reported in the scantly literature. The authors conclude that the parameters studied are directly related to age, except for a younger group with clear evidence of genital inflammation. The authors emphasize the impossibility to correlate morphology of prostatic calcifications with pathologic conditions: there are no specific symptoms clearly connected with calcification even though the inflammation is often associated with calcifications

  18. Study of wet incineration of organic matters under ultrasounds

    International Nuclear Information System (INIS)

    Rey-Gaurez, F.

    2001-01-01

    The purpose of this study is to investigate the potentiality of power ultrasound for minimizing the volumes of solid waste and effluents generated by the spent nuclear fuel refining industry. In the first part, the advantages of power ultrasound for the decontamination of ion exchange resins (IER) is demonstrated: 1) sonication allows to remove 100 % of the 137 Cs and more than 20 % of the 60 Co initially present in the contaminated resins, 2) the decontamination is fast, 3) very simple experimental conditions are necessary (water, air or argon as saturating gas and weak electric intensity). The study of different chemical and sono-chemical parameters shows that decontamination seems to be related to the effects induced by cavitation: micro-streaming and solid erosion or disruption. In the second part, the selectivity of power ultrasound for the elimination of nitrogen (nitrate, nitro) aliphatic derivatives diluted in the PUREX process solvent is established. The nitrogen derivatives of butane or dodecane are removed under sonication while the solvent is scarcely damaged. The nitrogen derivatives of butane are quickly eliminated according to a thermal way in the cavitation bubble. A great number of kinetic data have been obtained and the influence of different parameters has been studied. The mechanisms are complex and initiated mainly by the homolytic cleavage of the O-N bond of butyl nitrate or nitrite and the C-N bond of nitrobutane. The elimination of nitrogen derivatives of dodecane is slower than the four-carbon component one. This preliminary kinetic study was difficult as the kinetic order was undetermined and a steady state concentration was reached after a short time of sonication. Unlike the four-carbon derivatives, the decomposition rate was not controlled by the boiling point of the long-chain derivatives. Nevertheless, good carbon balance (dodecane is the major product) has been obtained and led to potential mechanisms. (author) [fr

  19. Ultrasound evaluation of the abductor hallucis muscle: Reliability study

    Directory of Open Access Journals (Sweden)

    Hing Wayne A

    2008-09-01

    Full Text Available Abstract Background The Abductor hallucis muscle (AbdH plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Results The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99; medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97 and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99. Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98; medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96 and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88. Conclusion Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

  20. Feasibility study of using industrial robot for ultrasound testing

    Energy Technology Data Exchange (ETDEWEB)

    Hsia, T.C. (California Univ., Davis, CA (USA). Dept. of Electrical Engineering and Computer Science)

    1989-02-13

    The purpose of this program is to study the feasibility of employing an articulated industrial robot arm to perform ultrasound scanning of a work piece. The robot arm suitable for such application is the Unimation PUMA 560 manipulator with six degrees of freedom. This research is intended to study the basic properties of several issues which arise in the operations of the UTB facility at LLNL. These issues involve the understanding of control algorithms for collision-free motions of the robot arm with and without redundant kinematics, trajectory generation schemes for automated surface tracking based on 3D CAD/CAM model of the work piece, and the effective use of computer vision and ultrasound sensor to achieve position calibration of a work piece and on-line trajectory modification for accurate surface tracking. The robotics research laboratory at UC Davis has a research robotic system based on a six degrees-of-freedom Unimation PUMA 560 arm and a VAL-II controller. This system is used as a research tool for the investigation. 20 refs., 8 figs.

  1. A comparative study in ultrasound breast imaging classification

    Science.gov (United States)

    Yap, Moi Hoon; Edirisinghe, Eran A.; Bez, Helmut E.

    2009-02-01

    American College of Radiology introduces a standard in classification, the breast imaging reporting and data system (BIRADS), standardize the reporting of ultrasound findings, clarify its interpretation, and facilitate communication between clinicians. The effective use of new technologies to support healthcare initiatives is important and current research is moving towards implementing computer tools in the diagnostics process. Initially a detailed study was carried out to evaluate the performance of two commonly used appearance based classification algorithms, based on the use of Principal Component Analysis (PCA), and two dimensional linear discriminant analysis (2D-LDA). The study showed that these two appearance based classification approaches are not capable of handling the classification of ultrasound breast image lesions. Therefore further investigations in the use of a popular feature based classifier - Support Vector Machine (SVM) was conducted. A pre-processing step before feature based classification is feature extraction, which involve shape, texture and edge descriptors for the Region of Interest (ROI). The input dataset to SVM classification is from a fully automated ROI detection. We achieve the success rate of 0.550 in PCA, 0.500 in LDA, and 0.931 in SVM. The best combination of features in SVM classification is to combine the shape, texture and edge descriptors, with sensitivity 0.840 and specificity 0.968. This paper briefly reviews the background to the project and then details the ongoing research. In conclusion, we discuss the contributions, limitations, and future plans of our work.

  2. Anterior gonalgic syndrome after intramedullary nailing: ultrasound and radiologic study.

    Science.gov (United States)

    Sala, F; Binda, M; Lovisetti, G

    1998-01-01

    A total of 33 patients submitted to tibial intramedullary osteosynthesis for fracture (27 cases) and non-union were assessed by ultrasound and x-rays an average of 10.9 months after surgery. The route of access was patellar transtendineal in each case; the means of synthesis used was the Marchetti Vicenzi nail. In 19 patients (57.6%) there was anterior gonalgia. Radiologic assessment evaluated prominence of the nail, while nail-tendon impingement was examined by ultrasound. Nail-tendon impingement was frequently observed (24 cases, 72.7%); in cases such as these anterior pain in the knee was present in 17 patients: however, this fact did not achieve statistical significance. The patellar tendon was thickened as compared to the contralateral one, with disorganization of the fibrillar echotexture, but it was not shortened. The tendinous morphostructure did not reveal any relationship with anterior gonalgia. In none of the cases did we observe the formation of scarring nuromas. In the area of the Hoffa body reactive synovitis phenomena with structural hyperechogenicity, an unclear aspect of the posterior tendinous profile and calcifications were observed. Radiographic prominence of the nail was correlated with echographic impingement, but not with clinical findings. Removal of the instrumentation carried out in 8 patients characterized by anterior gonalgia did not lead to resolution of symptoms in 2 cases in which MRI study showed patellar tendinitis and in 1 case patellar chondropathy with irregularity of the Hoffa body in the second.

  3. [Diagnosis. Radiological study. Ultrasound, computed tomography and magnetic resonance imaging].

    Science.gov (United States)

    Gallo Vallejo, Francisco Javier; Giner Ruiz, Vicente

    2014-01-01

    Because of its low cost, availability in primary care and ease of interpretation, simple X-ray should be the first-line imaging technique used by family physicians for the diagnosis and/or follow-up of patients with osteoarthritis. Nevertheless, this technique should only be used if there are sound indications and if the results will influence decision-making. Despite the increase of indications in patients with rheumatological disease, the role of ultrasound in patients with osteoarthritis continues to be limited. Computed tomography (CT) is of some -although limited- use in osteoarthritis, especially in the study of complex joints (such as the sacroiliac joint and facet joints). Magnetic resonance imaging (MRI) has represented a major advance in the evaluation of joint cartilage and subchondral bone in patients with osteoarthritis but, because of its high cost and diagnostic-prognostic yield, this technique should only be used in highly selected patients. The indications for ultrasound, CT and MRI in patients with osteoarthritis continue to be limited in primary care and often coincide with situations in which the patient may require hospital referral. Patient safety should be bourne in mind. Patients should be protected from excessive ionizing radiation due to unnecessary repeat X-rays or inadequate views or to requests for tests such as CT, when not indicated. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  4. CNS Intravascular Lymphoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Amer Awad

    2011-01-01

    Full Text Available Intravascular lymphoma is a rare but well-described entity. The clinical manifestations are heterogeneous. We report a case of a 59-year-old woman who presented initially with syncope followed by subacute cognitive decline that progressed to minimally conscious state. Shortly after the transfer to our tertiary center the patient died. Brain autopsy disclosed the diagnosis of B-cell intravascular lymphoma. We speculate that syncope could be the first manifestation of central nervous system intravascular lymphoma and should be considered in the differential diagnosis of unexplained syncope. In addition, we stress the importance of early brain biopsy in unexplained white matter disease.

  5. [Epidural anaesthesia: Simulated intravascular test dose with S(+) ketamine, lidocaine and adrenaline. A prospective, randomized, double blind and placebo controlled study].

    Science.gov (United States)

    Higueras, R; Errando, C L; Soriano-Bru, J L

    2015-02-01

    The use of a test dose in epidural anaesthesia is a safety recommendation. However specificity and sensitivity of the drugs used with this indication have been not conclusive. The main objective of this study was to compare the effectiveness and the adverse effects of a simulated intravascular test dose of adrenaline, lidocaine and S(+)-ketamine. A prospective, randomized, double blinded, placebo controlled study was designed. ASA I patients scheduled for elective surgery were included. These were randomized to the following study groups: S(+)-ketamine 0.5 mg.kg-1 (S+K group), 5% lidocaine 1.5 mg.kg-1 (L5% group), adrenaline 15μg (ADR group), and physiological saline 3 ml (SF group; control group). An evaluation was made during the first 15 minutes after the study drug was administered. Variables including heart rate (HR) systolic and diastolic blood pressure (sBP and dBP), mean arterial pressure (MAP), and SpO2 were recorded at 0 min (baseline) and at 2, 5, 8, 10 and 15 minutes after drug injection. An increase of at least 20 beats per minute (bpm) in relation to the baseline measurement was considered a positive result, as was an increase sBP >15 mmHg. The clinical effects described as related to iv injection of the study drugs recorded were: sedation-hypnosis, dizziness, nystagmus, metallic taste perception, perioral or facial paresthesias, tinnitus, as well as any other effect the patients mentioned. Sensitivity and specificity were calculated as was the percent increase in the parameters in order to see if these were clinically useful. A total of 80 patients, 20 per group, were included. The sBP, dBP, and MAP were significantly raised at the 2, 5, 8 and 10 minutes measurements in the S(+)K group compared to the rest of the groups (P<.05), as well as HR in the 2, 5, 8, 10 and 15 minute measurements in the S(+)K compared to the rest of the groups (P<.05). Sensitivity and specificity were high, and significant in the S(+)K group from minute 2 to minute 8

  6. Ultrasound study of the asymptomatic shoulder in patients with a ...

    African Journals Online (AJOL)

    Objective. To document the incidence of asymptomatic rotator cuff tears in patients with a confirmed symptomatic tear in the opposite shoulder, and to identify ultrasound findings that may distinguish symptomatic from asymptomatic tears. Design. When patients are referred for an ultrasound examination for the confirmation ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study may be part ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is ... into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , ...

  9. High speed intravascular photoacoustic imaging of atherosclerotic arteries (Conference Presentation)

    Science.gov (United States)

    Piao, Zhonglie; Ma, Teng; Qu, Yueqiao; Li, Jiawen; Yu, Mingyue; He, Youmin; Shung, K. Kirk; Zhou, Qifa; Kim, Chang-Seok; Chen, Zhongping

    2016-02-01

    Cardiovascular disease is the leading cause of death in the industrialized nations. Accurate quantification of both the morphology and composition of lipid-rich vulnerable atherosclerotic plaque are essential for early detection and optimal treatment in clinics. In previous works, intravascular photoacoustic (IVPA) imaging for detection of lipid-rich plaque within coronary artery walls has been demonstrated in ex vivo, but the imaging speed is still limited. In order to increase the imaging speed, a high repetition rate laser is needed. In this work, we present a high speed integrated IVPA/US imaging system with a 500 Hz optical parametric oscillator laser at 1725 nm. A miniature catheter with 1.0 mm outer diameter was designed with a 200 μm multimode fiber and an ultrasound transducer with 45 MHz center frequency. The fiber was polished at 38 degree and enclosed in a glass capillary for total internal reflection. An optical/electrical rotary junction and pull-back mechanism was applied for rotating and linearly scanning the catheter to obtain three-dimensional imaging. Atherosclerotic rabbit abdominal aorta was imaged as two frame/second at 1725 nm. Furthermore, by wide tuning range of the laser wavelength from 1680 nm to 1770 nm, spectroscopic photoacoustic analysis of lipid-mimicking phantom and an human atherosclerotic artery was performed ex vivo. The results demonstrated that the developed IVPA/US imaging system is capable for high speed intravascular imaging for plaque detection.

  10. Intravascular lipoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Z Doyle

    2015-06-01

    Full Text Available Lipomas are benign neoplasms composed of adipocytes encased in a fibrous capsule. Intravascular lipomas are rare and almost always incidental findings. In the published literature, the majority are described within the inferior vena cava (IVC and less frequently reported in the superior vena cava, brachiocephalic vein, subclavian vein, internal jugular vein, external iliac vein and common femoral vein. We present the case of a 59-year-old male who presented with a symptomatic ureteral calculus and was found to have an intravascular lipoma of the right renal vein with extension into the IVC. To our knowledge, this is the first ever report of an intravascular lipoma in the renal vein. We discuss the imaging characteristics of intravascular lipomas and the differential diagnosis that should be considered.

  11. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  12. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  13. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    Energy Technology Data Exchange (ETDEWEB)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne [Department of Radiology, Paris Cedex 05 (France); Dromain, Clarisse; Balleyguier, Corinne S. [Institut de cancerologie Gustave-Roussy, Department of Radiology, Villejuif (France); Breucq, Catherine [Universitair Ziekenhuis-VUB, Department of Radiology, Bruxelles (Belgium); Steyaert, Luc [Department of Radiology, Brugge (Belgium); Baldan, Enrica [Veneto Institute of Oncology (IOV)-IRCCS, Department of Radiology, Padua (Italy); Drevon, Harir [Numerus Ltd, Lyon (France)

    2013-09-15

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  14. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    International Nuclear Information System (INIS)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne; Dromain, Clarisse; Balleyguier, Corinne S.; Breucq, Catherine; Steyaert, Luc; Baldan, Enrica; Drevon, Harir

    2013-01-01

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  15. Imminent Cardiac Risk Assessment via Optical Intravascular Biochemical Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, D.; Wetzel, L; Wetzel, M; Lodder, R

    2009-01-01

    Heart disease is by far the biggest killer in the United States, and type II diabetes, which affects 8% of the U.S. population, is on the rise. In many cases, the acute coronary syndrome and/or sudden cardiac death occurs without warning. Atherosclerosis has known behavioral, genetic and dietary risk factors. However, our laboratory studies with animal models and human post-mortem tissue using FT-IR microspectroscopy reveal the chemical microstructure within arteries and in the arterial walls themselves. These include spectra obtained from the aortas of ApoE-/- knockout mice on sucrose and normal diets showing lipid deposition in the former case. Also pre-aneurysm chemical images of knockout mouse aorta walls, and spectra of plaque excised from a living human patient are shown for comparison. In keeping with the theme of the SPEC 2008 conference Spectroscopic Diagnosis of Disease this paper describes the background and potential value of a new catheter-based system to provide in vivo biochemical analysis of plaque in human coronary arteries. We report the following: (1) results of FT-IR microspectroscopy on animal models of vascular disease to illustrate the localized chemical distinctions between pathological and normal tissue, (2) current diagnostic techniques used for risk assessment of patients with potential unstable coronary syndromes, and (3) the advantages and limitations of each of these techniques illustrated with patent care histories, related in the first person, by the physician coauthors. Note that the physician comments clarify the contribution of each diagnostic technique to imminent cardiac risk assessment in a clinical setting, leading to the appreciation of what localized intravascular chemical analysis can contribute as an add-on diagnostic tool. The quality of medical imaging has improved dramatically since the turn of the century. Among clinical non-invasive diagnostic tools, laboratory tests of body fluids, EKG, and physical examination are

  16. Intrapartum assessment of caput succedaneum by transperineal ultrasound: a two-centre pilot study.

    Science.gov (United States)

    Hassan, Wassim A; Eggebo, Torbjorn M; Salvesen, Kjell A; Lindtjorn, Elsa; Lees, Christoph

    2015-08-01

    Digital assessments of caput succedaneum are subjective; however, caput succedaneum can also be expressed as ultrasound measured skin-skull distance (SSD). In this study, we aimed to compare the clinical and ultrasound assessment of caput succedaneum (caput) in nulliparous women in the first stage of labour. Furthermore, we aimed to investigate the repeatability of ultrasound measurements. We observed a significant but low correlation between clinical and ultrasound assessments (Kappa value 0.29; P caput measurements was -0.4 mm (95% CI, -0.85 to 0.05), and limits of agreement were -3.44 to 2.64 mm. We conclude that ultrasound measured SSD is an objective expression of caput with significant correlation with clinical assessment. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  17. A prospective study to compare the diagnostic performance of breast elastography versus conventional breast ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Leong, L.C.H., E-mail: lester.leong.c.h@sgh.com.s [Singapore General Hospital (Singapore); Sim, L.S.J.; Lee, Y.S.; Ng, F.C.; Wan, C.M.; Fook-Chong, S.M.C.; Jara-Lazaro, A.R.; Tan, P.H. [Singapore General Hospital (Singapore)

    2010-11-15

    Aim: To compare the diagnostic performance of breast elastography versus conventional ultrasound in the assessment of breast lesions. Materials and methods: The study was approved by the hospital's institutional review board. A prospective study involving 99 consecutive women who gave informed consent were enrolled from September 2007 to March 2008. One hundred and ten breast lesions were evaluated separately by conventional ultrasound, elastography and combined conventional ultrasound with elastography. Ultrasound assessment was based on the BIRADS classification, whereas elastographic assessment was based on strain pattern and the elastographic size ratios. Histological diagnosis was used as the reference standard. The sensitivity, specificity, and accuracy of each technique were compared. Results: The mean age of the patients was 46.7 years. Twenty-six lesions were malignant and 84 were benign. Sensitivity, specificity, and accuracy were 88.5, 42.9 and 53.6%, respectively, for conventional ultrasound, 100, 73.8, and 80%, respectively, for elastography, and 88.5, 78.6, and 80.9%, respectively, for combined imaging. The specificity and accuracy of elastography and combined imaging were significantly better than that of conventional ultrasound (p<0.0001), whereas there was no statistically significant difference in the sensitivity between all three groups. Two-thirds (66.7%) of sonographic false-positive lesions had benign elastogram findings, which might have been spared from biopsy. Conclusion: This initial experience with ultrasound breast elastography showed that it was more specific and more accurate than conventional ultrasound. Combining elastography with ultrasound improved specificity and accuracy of ultrasound and can potentially reduce unnecessary breast biopsies.

  18. Influence of ezetimibe in addition to high-dose atorvastatin therapy on plaque composition in patients with ST-segment elevation myocardial infarction assessed by serial Intravascular ultrasound with iMap: the OCTIVUS trial*

    DEFF Research Database (Denmark)

    Hougaard, Mikkel; Hansen, Henrik Steen; Thayssen, Per

    2017-01-01

    Background: The aim of this study was to examine the influence of ezetimibe in addition to atorvastatin on plaque composition in patients with first-time ST-segment Elevation Myocardial Infarction treated with primary percutaneous intervention. Methods: Eighty-seven patients were randomized ( 1: ...

  19. Ultrasound cervical length in predicting preterm birth: Prospective study

    Directory of Open Access Journals (Sweden)

    Achour Radhouane

    2017-08-01

    Full Text Available Background Preterm birth is a leading cause of perinatal morbidity and mortality and represents a major public health problem. It is associated with a 15–20 per cent mortality rate and remains responsible for 75 per cent of perinatal deaths in foetuses without anomalies. Aims The aim of this study was to evaluate the importance of cervical length measured in the first trimester (11–14 Weeks of amenorrhea “WA” and the second trimester (20–24 Weeks of amenorrhea” WA” in an asymptomatic population of singleton pregnancies to assess the risk of spontaneous preterm birth compared to the digital assessment. Methods We conducted a prospective, longitudinal study involving 117 asymptomatic women with singleton pregnancies between January and December 2015. Results In our study, the clinical examination had a low positive predictive value and a low sensibility for screening women at risk of preterm delivery. Cervical length less than 35mm between 12–14WA and 30mm between 22–24WA predicts the occurrence of preterm birth with a high sensitivity (Se, and specificity (Sp. Conclusion We conclude that ultrasound screening of preterm delivery is now highly recommended.

  20. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  1. Disseminated intravascular coagulation and massive obstetric hemorrhage. Management dilemma.

    Science.gov (United States)

    Al-Nuaim, Lulu A; Mustafa, Mohamed S; Abdel Gader, Abdel Galil M

    2002-06-01

    The objective of this retrospective study is to reflect on our experience on an optimal management for major postpartum hemorrhage, which would prevent the occurrence and complications of disseminated intravascular coagulation and minimize maternal mortality and morbidity. Ten cases out of the 30,000 of total deliveries of severe obstetric hemorrhage associated with disseminated intravascular coagulation were studied. This study was carried out over a 7 year period, October 1988 through to September 1995, at the Obstetric Unit, King Khalid University Teaching Hospital, Riyadh, Kingdom of Saudi Arabia. All of the 10 women received packed red blood cells, 8 had fresh frozen plasma, and 6 received platelet transfusion. The 10 cases developed disseminated intravascular coagulation following medical and surgical management, all women needed hysterectomy, 4 subtotal, 6 total, and 5 women had relaparotomy and pelvic packing. Two had bladder injuries. There was no maternal death. An early resort to hysterectomy when conservative measures fail, will minimize maternal morbidity and mortality. In case of continuous bleeding after hysterectomy, pelvic packing proved to be effective.

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  4. Hand tendon involvement in rheumatoid arthritis: an ultrasound study.

    Science.gov (United States)

    Filippucci, Emilio; Gabba, Alessandra; Di Geso, Luca; Girolimetti, Rita; Salaffi, Fausto; Grassi, Walter

    2012-06-01

    To assess the prevalence and the distribution of tendon involvement in the hands and wrists of patients with rheumatoid arthritis (RA) describing in detail the ultrasound (US) morphostructural and vascular tendon abnormalities. Ninety consecutive RA patients were included in the study. The following tendons were scanned bilaterally: flexor pollicis longus tendon, flexor digitorum superficialis, and profundus tendons of the II to the V fingers (at both finger and carpal tunnel levels), flexor carpi radialis tendon, and extensor tendons of the 6 compartments on the dorsal aspect of the wrist. The presence of US findings indicative of tenosynovitis and tendon damage was investigated. Tenosynovitis was found in at least 1 anatomic site of 44 (48.8%) of 90 patients. Tendon damage was found in at least 1 anatomic site of 39 (43.3%) of 90 patients. The focal tendon echotexture derangement was found in 294 of 5400 (5.4%) tendons, the partial and complete tears in 14 (0.3%), and in 3 (0.06%) tendons, respectively. The most frequently involved tendons were the flexor tendons of the II, III, and IV fingers and the extensor carpi ulnaris tendon. The present study provides evidence in favor of the ability of US to reveal a relatively high frequency of tendon involvement at the hand and wrist level in RA patients. These data can both facilitate US examinations in daily clinical practice and direct further investigations in the US assessment of tendon involvement in RA. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Femoral anteversion measured by ultrasound and CT: a comparative study

    International Nuclear Information System (INIS)

    Aamodt, A.; Terjesen, T.; Eine, J.; Kvistad, K.A.

    1995-01-01

    Both computed tomography (CT) and ultrasonography have been used successfully to estimate the femoral anteversion (AV) angle. In this study, AV angles in 20 human adult femurs were determined by ultrasonography and CT and the measurements compared. On CT the real AV angle was measured as the angle between the head-neck centreline and the posterior condylar plane. In addition, the angle between the anterior head-trochanter (HT) tangent and the posterior condylar plane was determined. The latter angle was also measured by ultrasonography using the tilted transducer technique. The mean interobserver variation in the ultrasound measurements was 1.9 . We found ultrasonography to correlate very well with CT, both when comparing with the HT angle (r=0.95) and with the AV angle (r=0.93). The HT angle was on average 4 greater than the AV angle. In this study the accuracy of ultrasonography was ±5 and the method is recommended for screening in patients with rotational disorders of the femur. (orig.)

  6. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    limbs) undergoing PTA of the superficial femoral or popliteal artery. The degree of stenosis, the diameter and area of the lumen and the morphological changes in the plaque were related to the short-term patency of the intervention, as evaluated by duplex scan and ankle branchial index. RESULTS: Fifteen...... arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  7. Intravascular ultrasound for iliac artery imaging. Clinical review

    DEFF Research Database (Denmark)

    Vogt, K G; Schroeder, T V

    2001-01-01

    IVUS is able to produce trans-sectional images of the iliac arteries at a high resolution. The three layered appearance of the arterial wall can be visualized. In the atherosclerotic diseased artery calcified plaques can be discerned from non-calcified plaques, and the distribution of the plaque......-eccentric or concentric-can be determined. IVUS seems to be superior to arteriography in quantifying the degree of stenosis, being able to relate the luminal area to the mediabounded area at the same site of the artery. The discrepancy between IVUS and arteriography is even greater when evaluating residualstenosis after...

  8. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation . A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion . Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  9. A Randomized, Double-Blind, Placebo-Controlled, Phase 2b Study to Evaluate the Safety and Efficacy of Recombinant Human Soluble Thrombomodulin, ART-123, in Patients With Sepsis and Suspected Disseminated Intravascular Coagulation

    NARCIS (Netherlands)

    Vincent, Jean-Louis; Ramesh, Mayakonda K.; Ernest, David; Larosa, Steven P.; Pachl, Jan; Aikawa, Naoki; Hoste, Eric; Levy, Howard; Hirman, Joe; Levi, Marcel; Daga, Mradul; Kutsogiannis, Demetrios J.; Crowther, Mark; Bernard, Gordon R.; Devriendt, Jacques; Puigserver, Joan Vidal; Blanzaco, Daniel U.; Esmon, Charles T.; Parrillo, Joseph E.; Guzzi, Louis; Henderson, Seton J.; Pothirat, Chaicharn; Mehta, Parthiv; Fareed, Jawed; Talwar, Deepak; Tsuruta, Kazuhisa; Gorelick, Kenneth J.; Osawa, Yutaka; Kaul, Inder

    2013-01-01

    Objectives: To determine the safety and efficacy of recombinant thrombomodulin (ART-123) in patients with suspected sepsis-associated disseminated intravascular coagulation. Design: Phase 2b, international, multicenter, double-blind, randomized, placebo-controlled, parallel group, screening trial.

  10. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    Methods. An HDI 5000 Phillips ultrasound scanner with microvascular imaging software and 2.5 ml SonoVue (Bracco spa, Milan) contrast was used to scan 50 consecutive patients (32 malignant and 18 benign, 49 with histologically confirmed breast lesions). Time-intensity curves of the regions of interest (ROI) placed over ...

  11. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  12. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s...

  13. Does Dopplersignal enhancement with Levovist improve the diagnostic confidence of duplex scanning of the iliac arteries?--(A pilot study with correlation to intravascular ultrasound)

    DEFF Research Database (Denmark)

    Vogt, K C; Jensen, F; Schroeder, T V

    1998-01-01

    To evaluate whether echo-enhancement with Levovist improves the diagnostic confidence of duplex scanning of the iliac arteries.......To evaluate whether echo-enhancement with Levovist improves the diagnostic confidence of duplex scanning of the iliac arteries....

  14. Web-Based Tool for Standardized Reporting of Thyroid Ultrasound Studies.

    Science.gov (United States)

    Stewart, Samuel A; Rajaraman, Murali; Costa, Andreu F

    2018-01-01

    Our objective was to create a user-friendly synoptically driven web-based tool for radiologists to report thyroid ultrasound studies and thereby improve the quality, completeness, and recommendations of reports. The tool, developed using JavaScript and PHP (hypertext preprocessor), provides radiologists with a way to generate complete thyroid ultrasound reports and automatically categorize thyroid nodules of varying suspicion. Future work will focus on integration with the radiology information system for seamless reporting and the development of a prospective database.

  15. Cost savings and clinical acceptability of an intravascular line tip culture triage policy.

    Science.gov (United States)

    Colston, J; Batchelor, B; Bowler, I C J W

    2013-05-01

    Culture of intravascular line tips is useful for the diagnosis of intravascular line-related phlebitis and bacteraemia. However, the test lacks specificity, with a low predictive value for intravascular line bacteraemia. A recent randomised study showed that predictive value could be increased and costs reduced by refrigerating intravascular lines and retrieving them for culture only if there was a bacteraemia in the seven days before or after the intravascular line was received. We studied whether a similar triage policy could be introduced into our 1400-bed National Health Service (NHS) teaching hospital in the UK. We assessed cost reduction in the laboratory and clinical acceptability. Data regarding the number of intravascular lines received, stored and cultured and blood cultures received was retrieved from the microbiology computer, for five-month periods before and after the introduction of the new triage policy. Of the 134 intravascular line tips received in the five months after the policy had been introduced, 101 (75%) were stored without retrieval and 33 were cultured. Of these, 7/134 (5%) were culture positive and three matched a concurrent blood culture. Audit showed that compliance with the policy was >98%. The estimated annual cost reduction following the introduction of the policy was £3,166.96. The policy was acceptable to clinicians. The policy was both cost saving and clinically acceptable. If the policy were adopted throughout the NHS in the UK, the annual cost saving to the service might be in the order of £300,000. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Antenatal hydronephrosis: Negative predictive value of normal postnatal ultrasound - a 5-year study

    Energy Technology Data Exchange (ETDEWEB)

    Moorthy, I.; Joshi, N.; Cook, J.V. E-mail: jcook@epsom-sthelier.nhs.uk; Warren, M

    2003-12-01

    AIM: To determine whether normal postnatal ultrasound, as part of a strict screening protocol for the detection and follow-up of antenatal hydronephrosis, effectively excludes the majority of babies with congenital urinary tract abnormalities that would otherwise present with a urinary tract infection. MATERIALS AND METHODS: We retrospectively reviewed all babies who had postnatal follow-up of antenatally detected hydronephrosis over a 5-year period at our institution, a district general Trust with a specialist paediatric unit. We then studied all babies presenting with urinary tract infection before their first birthday to our institution over the same period. By cross-referencing these two study groups we were able to determine which babies developed a urinary tract infection having been previously discharged after normal postnatal ultrasound. RESULTS: Four hundred and twenty-five babies had postnatal follow-up of antenatal hydronephrosis. Of these, 284 were investigated with ultrasound alone. In the same 5-year period, 230 babies presented with urinary tract infection before their first birthday. Only three of these babies had been previously discharged after normal postnatal ultrasound. The negative predictive value of a normal postnatal ultrasound was therefore 98.9% (281/284) for babies who subsequently presented with a urinary tract infection before their first birthday. CONCLUSION: Careful antenatal and postnatal ultrasound with strict protocols is effective in detecting congenital renal tract abnormalities. Infants discharged after normal postnatal ultrasound are highly unlikely to still have an undetected urinary tract abnormality. We suggest that all babies with antenatal hydronephrosis are started on prophylactic antibiotics at birth, pending further investigation. All babies without features of severe obstruction antenatally should have their postnatal ultrasound delayed for a month. We recommend selective use of micturating cystourethrogram (MCUG

  17. Osteotomy in direct sinus lift. A comparative study of the rotary technique and ultrasound

    Science.gov (United States)

    Peñarrocha-Diago, Miguel; Sanchez-Recio, Cristina; Peñarrocha-Oltra, David; Romero-Millán, Javier

    2012-01-01

    Purpose: The present study investigates sinus membrane rupture in direct maxillary sinus lift with the rotary technique and with ultrasound, examining the survival of implants placed after sinus augmentation, and analyzing the bone gain obtained after the operation and 12 months after placement of the prosthetic restoration. Material and Methods: A retrospective study was made of 45 patients requiring maxillary sinus lift or augmentation for implant-prosthetic rehabilitation. Use was made of the hand piece and ostectomy drills for the rotary technique, and of specific tips for ultrasound. The implant success criteria were based on those developed by Buser. The bone gain obtained as a result of sinus lift was calculated from the postoperative panoramic X-rays. Results: A total of 57 direct elevations of the maxillary sinus were carried out: 32 with the rotary technique and 25 with ultrasound. Perforations of Schneider’s membrane with the rotary technique and ultrasound occurred in 7% and 1.7% of the cases, respectively, with membrane integrity being preserved in 91.2%. Of the 100 implants placed, 5 failed after one year of follow-up in the rotary technique group, while one implant failed in the ultrasound group. The rotary technique in turn afforded a bone gain of 5.9 mm, versus 6.7 mm with ultrasound. Conclusions: Perforations of the membrane sinusal in direct lift were more frequent with the rotary technique (7%) than with ultrasound (1.7%). Implant survival and bone gain were both greater when ultrasound was used. Key words:Bone sectioning, maxillary sinus augmentation, piezosurgery. PMID:22143735

  18. Antenatal hydronephrosis: Negative predictive value of normal postnatal ultrasound - a 5-year study

    International Nuclear Information System (INIS)

    Moorthy, I.; Joshi, N.; Cook, J.V.; Warren, M.

    2003-01-01

    AIM: To determine whether normal postnatal ultrasound, as part of a strict screening protocol for the detection and follow-up of antenatal hydronephrosis, effectively excludes the majority of babies with congenital urinary tract abnormalities that would otherwise present with a urinary tract infection. MATERIALS AND METHODS: We retrospectively reviewed all babies who had postnatal follow-up of antenatally detected hydronephrosis over a 5-year period at our institution, a district general Trust with a specialist paediatric unit. We then studied all babies presenting with urinary tract infection before their first birthday to our institution over the same period. By cross-referencing these two study groups we were able to determine which babies developed a urinary tract infection having been previously discharged after normal postnatal ultrasound. RESULTS: Four hundred and twenty-five babies had postnatal follow-up of antenatal hydronephrosis. Of these, 284 were investigated with ultrasound alone. In the same 5-year period, 230 babies presented with urinary tract infection before their first birthday. Only three of these babies had been previously discharged after normal postnatal ultrasound. The negative predictive value of a normal postnatal ultrasound was therefore 98.9% (281/284) for babies who subsequently presented with a urinary tract infection before their first birthday. CONCLUSION: Careful antenatal and postnatal ultrasound with strict protocols is effective in detecting congenital renal tract abnormalities. Infants discharged after normal postnatal ultrasound are highly unlikely to still have an undetected urinary tract abnormality. We suggest that all babies with antenatal hydronephrosis are started on prophylactic antibiotics at birth, pending further investigation. All babies without features of severe obstruction antenatally should have their postnatal ultrasound delayed for a month. We recommend selective use of micturating cystourethrogram (MCUG

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  20. Intravascular leiomyomatosis: an exceptional entity.

    Science.gov (United States)

    Brunel, I; Iacoponi, S; Hernandez, A; Diestro, M D; De Santiago, J; Zapardiel, I

    2016-01-01

    Intravenous leiomyomatosis (IVL) is a rare benign condition characterized by the proliferation of smooth muscle cells originating from either the uterine venous wall or a uterine myoma. This leiomyomatosis extends most frequently to pelvic vessels, but also occasionally into the inferior vena cava and right cardiac chambers. Preoperative diagnosis is difficult and it should be suspected in the presence of cardiac or pelvic masses in women who have undergone hysterectomy or myomectomy previously. The treatment is hysterectomy, normally associated with a bilateral oophorectomy and removing the mass or metastasis if any. The post-surgical follow-up should be performed at long-term and include exploration and imaging, either ultrasound or MRI. The association of antiestrogenic drugs can be useful for disease control, especially in cases where oophorectomy is not performed and the tumor cannot be removed completely.

  1. Choroid metastasis of papillary thyroid carcinoma. Color doppler ultrasound study

    International Nuclear Information System (INIS)

    Ganado, T.; Torre, S. de la; Contreras, E.; Hernandez, J.

    1997-01-01

    The most common causes of intraocular metastases are breast and lung cancers, although many other neoplasms can metastasize to the eye. Most of the metastases are located in the posterior pole and the choroid is more often involved than the retina. We present a case of a choroidal metastasis from a papillary carcinoma of the thyroid, associated with a massive subretinal hemorrhage. Findings with color Doppler ultrasound are emphasized. (Author) 9 refs

  2. Neutrophils Cause an Intravascular Traffic Jam.

    Science.gov (United States)

    Minns, Martin S; Pearlman, Eric

    2018-01-10

    Neutrophil swarming is defined by large numbers of cells simultaneously and rapidly migrating to a site of injury or infection. In this issue of Cell Host & Microbe, Lee et al. (2018) demonstrate that intravascular swarming of neutrophils occurs in response to Candida albicans infection and causes vascular occlusion and pathological sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  4. Disseminated Intravascular Coagulation Following Induction of ...

    African Journals Online (AJOL)

    Background: Disseminated Intravascular coagulopathy (DIC) has been reported following use of Misoprostol which is an old drug with new indications in Obstetrics and. Gynecology. Its effectiveness, low cost, stability in tropical conditions and ease of administration as well as side effects like gastrointestinal effect, uterine ...

  5. Dynamic contrast enhanced ultrasound assessment of the vascular effects of novel therapeutics in early stage trials.

    Science.gov (United States)

    Leen, Edward; Averkiou, Michalakis; Arditi, Marcel; Burns, Peter; Bokor, Daniela; Gauthier, Thomas; Kono, Yuko; Lucidarme, Olivier

    2012-07-01

    Imaging is key in the accurate monitoring of response to cancer therapies targeting tumour vascularity to inhibit its growth and dissemination. Dynamic contrast enhanced ultrasound (DCE ultrasound) is a quantitative method with the advantage of being non-invasive, widely available, portable, cost effective, highly sensitive and reproducible using agents that are truly intravascular. Under the auspices of the initiative of the Experimental Cancer Medicine Centre Imaging Network, bringing together experts from the UK, Europe and North America for a 2-day workshop in May 2010, this consensus paper aims to provide guidance on the use of DCE ultrasound in the measurement of tumour vascular support in clinical trials. Key Points • DCE ultrasound can quantify and extract specific blood flow parameters, such as flow velocity, relative vascular volume and relative blood flow rate. • DCE ultrasound can be performed repeatedly and is therefore ideally suited for pharmacokinetic and pharmacodynamic studies evaluating vascular-targeted drugs. • DCE ultrasound provides a reproducible method of assessing the vascular effects of therapy in pre-clinical and early clinical trials, which is easily translatable into routine clinical practice.

  6. Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

    Science.gov (United States)

    Ameri, Golafsoun; Baxter, John S H; Bainbridge, Daniel; Peters, Terry M; Chen, Elvis C S

    2018-04-01

    Real-time ultrasound has become a crucial aspect of several image-guided interventions. One of the main constraints of such an approach is the difficulty in interpretability of the limited field of view of the image, a problem that has recently been addressed using mixed reality, such as augmented reality and augmented virtuality. The growing popularity and maturity of mixed reality has led to a series of informal guidelines to direct development of new systems and to facilitate regulatory approval. However, the goals of mixed reality image guidance systems and the guidelines for their development have not been thoroughly discussed. The purpose of this paper is to identify and critically examine development guidelines in the context of a mixed reality ultrasound guidance system through a case study. A mixed reality ultrasound guidance system tailored to central line insertions was developed in close collaboration with an expert user. This system outperformed ultrasound-only guidance in a novice user study and has obtained clearance for clinical use in humans. A phantom study with 25 experienced physicians was carried out to compare the performance of the mixed reality ultrasound system against conventional ultrasound-only guidance. Despite the previous promising results, there was no statistically significant difference between the two systems. Guidelines for developing mixed reality image guidance systems cannot be applied indiscriminately. Each design decision, no matter how well justified, should be the subject of scientific and technical investigation. Iterative and small-scale evaluation can readily unearth issues and previously unknown or implicit system requirements. We recommend a wary eye in development of mixed reality ultrasound image guidance systems emphasizing small-scale iterative evaluation alongside system development. Ultimately, we recommend that the image-guided intervention community furthers and deepens this discussion into best practices in

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  8. [Ultrasound in complex of radiological studies in diagnosis of ankle joint medial aspect pathologies].

    Science.gov (United States)

    Gurgenidze, T; Mizandari, M

    2011-10-01

    The aim of the research is to study sonosemiotics of ankle joint pathology by means of ultrasound in order to optimize the diagnostic process and improve the treatment. 130 patients (age ranges from 5 to 70 years) underwent the radiological study of ankle joint medial aspect. Pathology types: degenerative-dystrophic diseases - 39 (30%), inflammatory pathology - 21 (16.2%), traumatic injuries - 20 (15.2%), vascular pathologies - 26 (20%), neurogenic problems -7 (5.4%), soft tissue neoplasms - 5 (3.8%), congenital anomalies - 7 (5.4%) and vertebral pathology - 5 (4.0%). The diagnostic studies include: a) Ultrasound, performed on digital ultrasound system using high frequency (7.5-12.0 MHz) linear probe with Doppler capability (all patients); b) X-Ray filming in antero-posterior and lateral projections (6 patients- 4.5%); c) MRI - T1 and T2 weighted images in saggital and transverse planes 10 patients (10.0%) and d) CT - 2 patients (1.5%); To 2 (1.5%) patient biopsy has been performed. This study showed that ultrasound was successful in ankle joint medial aspect pathology diagnosis in 108 cases (84.0%); It was ineffective in osseous pathology definition. In final diagnosis of impingment syndrom MRI was required in 4 (3.6%) cases. It is concluded that ultrasound should be used as a Gold Standard in diagnosis of localized pain and swelling in the ankle joint.

  9. FD-OCT and IVUS intravascular imaging modalities in peripheral vasculature.

    Science.gov (United States)

    Spiliopoulos, S; Kitrou, P; Katsanos, K; Karnabatidis, D

    2017-02-01

    Intra-Vascular Ultra-Sound (IVUS) and Frequency Domain-Optical Coherence Tomography (FD-OCT), in vivo, intra-vascular, imaging modalities, widely used in the field of coronary disease, have been recently implemented in peripheral endovascular procedures, for procedural assessment, plaque characterization and determination of predictors of treatment outcomes. Their unique characteristics have also been used in order to provide additional features and improve the performance of re-entry devices and atherotomes. Areas covered: Present review focuses on available literature regarding these two promising imaging technologies in the peripheral vasculature, highlighting the added value produced by their use in endovascular therapy, their limitations and their utilization in new endovascular devices. Authors also provide their future perspective and the possible benefits in understanding vascular behavior and lesion characterization in peripheral endovascular interventions. Expert commentary: By providing both quantitative but also qualitative data on vessel and lesion morphology, intravascular imaging modalities offer a valid solution for endovascular treatment evaluation and outcome presentation homogeneity.

  10. Ultrasound study of skin tumors; Estudio ecografico de lesiones tumorales de la piel

    Energy Technology Data Exchange (ETDEWEB)

    Marques, J.; Cueto, L.; Roldan, F.; Perez, I.; Rangel, M. E.; Garcia, A. [Hospital Universitario Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To study the ultrasonographic features associated with different skin tumors. Between June 2000 and May 2001, ultrasound studies using a 10MHz-circular array transducer were performed in 53 patients with skin tumors. Each lesion was analyzed to assess the following ultrasonographic features: shape, size, margins, neighborhood relations and ultrastructure (echogenicity, homogeneity and ultrasound conduction). The lesions studied included 5 epidermal nevi, 2 epidermal cysts 6 basal cell carcinomas, 5 spindle cell carcinomas, 10 sebaceous cysts, 1 lymph angioma, 5 hemangiomas, 6 benign fibrous histiocytomas, 3 cases of dermatofibrosarcoma protuberans. 2 plexiformneurofibromas. 4 lipomas, 1. melanocyte nevus and 3 malignant melanomas. The ultrasonographic features of different skin tumors are described. The use of high-frequency probes is indispensable in the study of the epidermis. Ultrasound allows the determination of the extension of the lesion, a feature that is especially useful in cases of melanoma. (Author) 24 refs.

  11. Optical fiber laser ultrasound transmitter with electrospun composite for minimally invasive medical imaging

    Science.gov (United States)

    Poduval, Radhika; Noimark, Sacha; Colchester, Richard; Macdonald, Tom; Parkin, Ivan; Desjardins, Adrien; Papakonstantinou, Ioannis

    2017-07-01

    We report an optical fiber ultrasound transmitter with electrospun MWCNT-polymer composite, generating high-amplitude broadband ultrasound. They produced pressures in the range of conventional intravascular imaging transducers, and can be incorporated into catheters/needles for keyhole surgery

  12. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  13. Renal ultrasound studies after endoscopic injection of dextranomer/hyaluronic acid copolymer for vesicoureteral reflux.

    Science.gov (United States)

    Yu, Richard N; Jones, Eric A; Roth, David R

    2006-10-01

    To examine the outcomes of renal ultrasound studies after subureteral injection of dextranomer/hyaluronic acid copolymer and provide recommendations for postoperative management of vesicoureteral reflux (VUR). Pediatric patients aged 15 years or younger with uncomplicated primary VUR were recruited for endoscopic treatment with dextranomer/hyaluronic acid gel. After undergoing the procedure, patients were instructed to continue prophylactic antibiotic treatment until a follow-up voiding cystourethrogram was obtained 2 weeks or more after treatment. VUR resolution was defined as grade 0. Repeat endoscopic injection was offered to patients with persistent VUR. Postoperative renal ultrasound scans were obtained on the same day as the voiding cystourethrogram. Of 120 patients treated, 6 were lost to follow-up and 14 had not yet undergone the posttreatment evaluation. The 100 remaining patients (efficacy population) had a mean age of 4.2 years (range 0.5 to 15), and the median reflux grade was 2 (range 1 to 5). The overall VUR resolution rate for the patients was 87% after endoscopic injection. Of 100 patients, 88 achieved complete resolution after a single injection and 19 required a repeat injection. Of the 100 patients who underwent postoperative ultrasound examination, none demonstrated renal ultrasound changes consistent with significant ureteral obstruction or renal parenchymal changes. Renal ultrasound studies after endoscopic treatment with dextranomer/hyaluronic acid gel are unnecessary after determination of reflux resolution by voiding cystourethrography.

  14. Basic study on ultrasonic monitoring using 1.5-dimensional ultrasound phased array for ultrasound-guided high-intensity focused ultrasound treatment

    Science.gov (United States)

    Takagi, Ryo; Iwasaki, Ryosuke; Tomiyasu, Kentaro; Yoshizawa, Shin; Umemura, Shin-ichiro

    2017-07-01

    We have been studying a real-time detection method for tissue changes induced by high-intensity focused ultrasound (HIFU) treatment using ultrasonic RF signals. It has been difficult to track the target region when the tissue to be treated deviates from the imaging plane along the elevation axis of the probe. In this study, a new 1.5-dimensional (1.5D) prototype phased array probe consisting of transducer elements along both the lateral and elevation axes was developed to track tissue motion along the elevation axis of the probe, and the elevational displacement range where the tracking is effective was investigated. The complex cross-correlation coefficient based on a block matching algorithm was applied to 2.5D volumetric RF images acquired by the 1.5D probe and the displacement vector along the elevation axis was calculated. From the results, it was found that the effective tracking range using this prototype probe was up to 3 mm, about 3 times that of a conventional 1D imaging probe. The proposed 1.5D phased array probe has the potential to track target tissue with intrafractional motion.

  15. Obstetrical Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures of ... What are the limitations of Obstetrical Ultrasound Imaging? Obstetric ultrasound cannot identify all fetal abnormalities. Consequently, when ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  20. INTRAVASCULAR ENDOTHELIOMA (ENDOTHELIOMA IN SITU, SYSTEMIC ENDOTHELIOMATOSIS).

    Science.gov (United States)

    HABER, H; HARRIS-JONES, J N; WELLS, A L

    1964-11-01

    A woman aged 48 years was found to be suffering from intravascular endothelioma. The initial clinical presentation was the presence of red, painless swellings in the skin of the lower limbs. The other clinical features, and the histological changes in skin biopsies, are described and compared with those in the two previously reported patients. It is suggested that the condition is analogous to the pre-invasive carcinomatous states.

  1. Impact of a 2-Day Critical Care Ultrasound Course during Fellowship Training: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Vi Am Dinh

    2015-01-01

    Full Text Available Objectives. Despite the increasing utilization of point-of-care critical care ultrasonography (CCUS, standards establishing competency for its use are lacking. The purpose of this study was to evaluate the effectiveness of a 2-day CCUS course implementation on ultrasound-naïve critical care medicine (CCM fellows. Methods. Prospective evaluation of the impact of a two-day CCUS course on eight CCM fellows’ attitudes, proficiency, and use of CCUS. Ultrasound competency on multiple organ systems was assessed including abdominal, pulmonary, vascular, and cardiac systems. Subjects served as self-controls and were assessed just prior to, within 1 week after, and 3 months after the course. Results. There was a significant improvement in CCM fellows’ written test scores, image acquisition ability, and pathologic image interpretation 1 week after the course and it was retained 3 months after the course. Fellows also had self-reported increased confidence and usage of CCUS applications after the course. Conclusions. Implementation of a 2-day critical care ultrasound course covering general CCUS and basic critical care echocardiography using a combination of didactics, live models, and ultrasound simulators is effective in improving critical care fellows’ proficiency and confidence with ultrasound use in both the short- and long-term settings.

  2. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  3. Breast contrast-enhanced ultrasound: is a scoring system feasible? A preliminary study in China.

    Directory of Open Access Journals (Sweden)

    Xiaoyun Xiao

    Full Text Available Although many studies about breast contrast-enhanced ultrasound had been conducted, clear diagnostic criteria for evaluating enhancement patterns are still lacking. This study aims to identify significant indicators for breast contrast-enhanced ultrasound and to establish an initial scoring system.Totally 839 patients were included in the study. This study was divided into two parts. 364 patients were included in part 1 while 475 in part 2. Conventional ultrasound and contrast-enhanced ultrasound were used to examine each lesion. Only the cases in part 2 were also examined by elastography. In part 1, Logistic regression analysis was performed to predict significant variables. A 5-point scoring system was developed based on the results. In part 2, the scoring system was used to evaluate all the breast lesions. To evaluate the diagnostic efficacy of the new scoring system, it was compared with the system established for elastography and conventional ultrasound (BI-RADS.Three independent variables, namely, lesion scope, margin, and shape were selected in the final step of the logistic regression analysis in part 1. In part 2, the area under the ROC (receiver operating characteristic curve for the contrast-enhanced scoring system was 0.912. The difference in the diagnostic capabilities of the contrast-enhanced scoring system and elastography was not statistically significant (P = 0.17. The difference in the diagnostic capabilities of the contrast-enhanced scoring system and BI-RADS was statistically significant (P<0.001.The contrast-enhanced patterns of benign and malignant breast tumors are different. The application of a 5-point scoring system for contrast-enhanced ultrasound is clinically promising.

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  5. Can ultrasound abdomen help in early diagnosis of diabetes mellitus? an observational study

    International Nuclear Information System (INIS)

    Anwar, J.; Aamir, M.O.; Imdad, Z.U.H.

    2015-01-01

    Diabetes mellitus is a common disease. Similarly, ultrasound findings of fatty change and renal crystals are commonly seen on ultrasound. In the personal observation of the main author over the past so many years it was noticed that Diabetes Mellitus, Fatty liver and renal crystals all sit well together. This study tries to establish a relationship between diabetes mellitus renal echogenic foci and fatty liver. This study is first of its kind, as nobody has ever before investigated an association between the renal echogenic foci and fatty liver in relation to diabetes mellitus. Methods: This cross-sectional, observational study was conducted at Radiology Department Combined Military Hospital, Kohat From 2nd June 2013 to 30th May 2014. Three hundred patients were collected on the basis of having fatty liver and renal echogenic foci on ultrasound and three hundred more patients were collected who had no fatty liver or renal echogenic foci on ultrasound. Their labs were done for diabetes mellitus. Results: The patients having renal echogenic foci together with fatty liver had 83% positive rate of being diabetics, while patients with no fatty liver and no echogenic foci on ultrasonography had only 0.6% Positive rate of being diabetics. Conclusion: Our results provided the first demonstration of an association between renal echogenic foci together with fatty liver with the diabetes mellitus. Thus ultrasound examination of abdomen can be helpful in its early diagnosis if we make a protocol of doing fasting and random blood sugars in all those patients who have positive renal echogenic foci and fatty liver on their ultrasound examination. (author)

  6. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    Full Text Available OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM com Tecnécio 99m-MIBI (MIBI e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ e o ultra-som intracoronário (UIC como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC, encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E% de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79% e média de 44,20%, pOBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA and intravascular ultrasound (IVUS. METHODS: Seventy patients with coronary artery disease (CAD referred for myocardial perfusion scintigraphy (MPS with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG, and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%, mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%, p<0.05. Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA. Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD and minimal lumen area

  7. A Prospective Randomized Study to Evaluate a New Learning Tool for Ultrasound-Guided Regional Anesthesia.

    Science.gov (United States)

    Das Adhikary, Sanjib; Karanzalis, Demetrius; Liu, Wai-Man Raymond; Hadzic, Admir; McQuillan, Patrick M

    2017-05-01

    To evaluate the effectiveness of a new learning tool for needle insertion accuracy skills during a simulated ultrasound-guided regional anesthesia procedure. Thirty participants were included in this randomized controlled study. After viewing a prerecorded video of a single, discreet, ultrasound-guided regional anesthesia task, all participants performed the same task three consecutive times (pretest), and needle insertion accuracy skills in a phantom model were recorded as baseline. All participants were then randomized into two groups, experimental and control. The experimental group practiced the task using the new tool, designed with two video cameras, a monitor, and an ultrasound machine where the images from the ultrasound and video of hand movements are viewed simultaneously on the monitor. The control group practiced the task without using the new tool. After the practice session, both groups repeated the same task and were evaluated in the same manner as in the pretest. Participants in both group groups had similar baseline characteristics with respect to previous experience with ultrasound-guided regional anesthesia procedures. The experimental group had significantly better needle insertion accuracy scores ( P  < 0.01) than the control group. Using the new learning tool, inexperienced participants had better needle insertion accuracy scores ( P  < 0.01) compared with experienced participants. This study demonstrates that the use of this new learning tool results in short-term improvement in hand-eye, motor, and basic needle insertion skills during a simulated ultrasound-guided regional anesthesia procedure vs traditional practice methods. Skill improvement was greater in novices compared with experienced participants. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. A study on the incidence of thyroid cancer in gender ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Eun Suk; Lim, Cheong Hwan [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Yang, Oh Nam [Dept. of Radiology, Mokpo Science University, Mokpo (Korea, Republic of)

    2015-06-15

    Thyroid nodules are an endocrine disease often found in clinical practice, and patients with thyroid nodules found by chance have rapidly increased alongside development of thyroid ultrasound techniques for health examination purposes. This study analyzes the subjects’ general characteristics, thyroid ultrasounds, and fine needle aspiration cytology in order to find out the relationship between male and female thyroid nodules and thyroid cancer frequency. An ultrasound examination of the thyroid was performed for 32,973 individuals who visited the K Hospital of Health Examination. Subjects have no history of thyroid disease and are 20 years old or over. Data of general characteristics, diabetes) was collected by a written survey completed by the subject, and the ultrasound of the thyroid (thyroid nodules existence, size, number) and FNAC was used to find out the malignancy rate. Frequency of patients with thyroid nodule was 4,611 (26.1%) in men and 5,341 (34.9%) in women between 32,973 individuals. Women’s prevalence rate is significantly higher than men, and the prevalence rate significantly increased with age in men and women (p<0.05). The prevalence of multiple nodules was significantly higher in women (43.5%) than in men (35.6%), and significantly increased with age in men and women (p<0.05). The fine needle aspiration cytology was performed in 692 (men 342, women 350) subjects who showed signs of malignancy through ultrasound. Prevalence of malignancy of the nodules was higher in men (33.3%) than in women (29.4%) although it is not statistically significant. It is known that thyroid nodule prevalence in women is much higher than in men. But this study shows the men’s prevalence rate was not too low compared with women, and the men showed a rather higher malignancy rate in nodules than women. It is considered that the role of thyroid ultrasound is both important in men and women.

  9. A study on the incidence of thyroid cancer in gender ultrasound

    International Nuclear Information System (INIS)

    Kwak, Eun Suk; Lim, Cheong Hwan; Yang, Oh Nam

    2015-01-01

    Thyroid nodules are an endocrine disease often found in clinical practice, and patients with thyroid nodules found by chance have rapidly increased alongside development of thyroid ultrasound techniques for health examination purposes. This study analyzes the subjects’ general characteristics, thyroid ultrasounds, and fine needle aspiration cytology in order to find out the relationship between male and female thyroid nodules and thyroid cancer frequency. An ultrasound examination of the thyroid was performed for 32,973 individuals who visited the K Hospital of Health Examination. Subjects have no history of thyroid disease and are 20 years old or over. Data of general characteristics, diabetes) was collected by a written survey completed by the subject, and the ultrasound of the thyroid (thyroid nodules existence, size, number) and FNAC was used to find out the malignancy rate. Frequency of patients with thyroid nodule was 4,611 (26.1%) in men and 5,341 (34.9%) in women between 32,973 individuals. Women’s prevalence rate is significantly higher than men, and the prevalence rate significantly increased with age in men and women (p<0.05). The prevalence of multiple nodules was significantly higher in women (43.5%) than in men (35.6%), and significantly increased with age in men and women (p<0.05). The fine needle aspiration cytology was performed in 692 (men 342, women 350) subjects who showed signs of malignancy through ultrasound. Prevalence of malignancy of the nodules was higher in men (33.3%) than in women (29.4%) although it is not statistically significant. It is known that thyroid nodule prevalence in women is much higher than in men. But this study shows the men’s prevalence rate was not too low compared with women, and the men showed a rather higher malignancy rate in nodules than women. It is considered that the role of thyroid ultrasound is both important in men and women

  10. Membrane design of an all-optical ultrasound receiver

    NARCIS (Netherlands)

    Leinders, S.M.; Dongen, K.W.A. van; Jong, N. de; Verweij, M.D.; Westerveld, W.J.; Urbach, H.P.; Neer, P.L.M.J. van; Pozo Torres, J.M.

    2013-01-01

    Ultrasound sensors such as piezoelectric transducers and CMUTs are successfully used for medical imaging. However, especially wiring of individual elements is difficult in the fabrication of small piezoelectric arrays, used in, e.g. the field of intravascular imaging. As an alternative, we designed

  11. Ultrasound Biomicroscopy for Longitudinal Studies of Carotid Plaque Development in Mice: Validation with Histological Endpoints

    NARCIS (Netherlands)

    Harmon, Erin Y.; Fronhofer, Van; Keller, Rebecca S.; Feustel, Paul J.; Brosnan, M. Julia; von der Thüsen, Jan H.; Loegering, Daniel J.; Lennartz, Michelle R.

    2012-01-01

    Atherosclerosis is responsible for the death of thousands of Americans each year. The carotid constriction model of plaque development has recently been presented as a model for unstable plaque formation in mice. In this study we 1) validate ultrasound biomicroscopy (UBM) for the determination of

  12. Performance of Ultrasound in the Diagnosis of Gout in a Multi-Center Study

    DEFF Research Database (Denmark)

    Ogdie, Alexis; Taylor, William J; Neogi, Tuhina

    2017-01-01

    OBJECTIVES: To examine the performance of ultrasound for the diagnosis of gout using presence of monosodium urate (MSU) crystals as the gold standard. METHODS: We analyzed data from the Study for Updated Gout Classification Criteria (SUGAR), a large, multi-center observational cross-sectional stu...

  13. Ultrasound-guided block of the axillary nerve: a volunteer study of a new method

    DEFF Research Database (Denmark)

    Rothe, C; Asghar, S; Andersen, H L

    2011-01-01

    Interscalene brachial plexus block (IBPB) is the gold standard for perioperative pain management in shoulder surgery. However, a more distal technique would be desirable to avoid the side effects and potential serious complications of IBPB. Therefore, the aim of the present study was to develop...... and describe a new method to perform an ultrasound-guided specific axillary nerve block....

  14. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  15. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  16. A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound Phantoms.

    Science.gov (United States)

    Scorza, A; Conforto, S; D'Anna, C; Sciuto, S A

    2015-01-01

    To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. In the present study variations on some features of the B-mode image were measured when the ultrasound probe is handled by the technician in a routine image quality test: ultrasound phantom images from two array transducers are processed to evaluate measurement dispersion in distance accuracy, high contrast spatial resolution and penetration depth when probe is handled by the operator. All measurements are done by means of an in-house image analysis software that minimizes errors due to operator's visual acuity and subjective judgment while influences of ultrasound transducer position on quality assurance test results are estimated as expanded uncertainties on parameters above (measurement reproducibility at 95 percent confidence level): depending on the probe model, they ranged from ±0.1 to ±1.9 mm in high contrast spatial resolution, from ±0.1 to ±5.5 percent in distance measurements error and from ±1 to ±10 mm in maximum depth of signal visualization. Although numerical results are limited to the two examined probes, they confirm some predictions based on general working principles of diagnostic ultrasound systems: (a) measurements strongly depend on settings as well on phantoms features, probes and parameters investigated; (b) relative uncertainty due to probe manipulation on spatial resolution can be very high, i.e. from 10 to more than 30 percent; (c) Field of View settings must be taken into account for measurement reproducibility as well as Dynamic Range compression and phantom attenuation.

  17. Early assessment of chronic kidney dysfunction using contrast-enhanced ultrasound: a pilot study

    Science.gov (United States)

    Dong, Y; Cao, J; Fan, P; Lin, X

    2014-01-01

    Objective: We performed a prospective study to evaluate the value of contrast-enhanced (CE) ultrasound in quantitative evaluation of renal cortex perfusion in patients with chronic kidney dysfunction (CKD Stage I–II). Methods: The present study was approved by the institutional ethics committee. The study focused on 41 consecutive patients (males, 32; females, 9; mean age, 55.0 ± 5.0 years) with clinical suspicion of CKD (Stages I–II). For both kidneys, CE ultrasound was performed after intravenous bolus injection of 1.0 ml SonoVue® (Bracco Imaging S.p.A., Milan, Italy). Time–intensity curves (TICs) and quantitative indexes were created with Qlab software (Philips, Bothell, WA). 45 healthy volunteers were included as control group. All statistical analyses were performed with SPSS® v. 15.0 software package (SPSS, Chicago, IL). A difference was considered statistically significant with p 2 and AUC >1300 dB s had high utility in the evaluation of CKD, with 81%, 73% and 78% specificities and 76%, 73% and 77% sensitivities. Conclusion: CE ultrasound might be valuable in the early evaluation of CKD. AUC, A and DPI might be valuable quantitative indexes. Advances in knowledge: Quantitative CE ultrasound analysis can be used for the standardized and early evaluation of renal dysfunction. PMID:25060882

  18. Acorrelation study between histological results and thyroid ultrasound findings. The TI-RADS classification.

    Science.gov (United States)

    García-Moncó Fernández, Carlos; Serrano-Moreno, Clara; Donnay-Candil, Sergio; Carrero-Alvaro, Juan

    2018-04-01

    There are several classifications based on thyroid ultrasound for selecting suspected malignant thyroid nodules. The Thyroid Imaging Reporting and Data System (TI-RADS) classification proposed by Horvath in 2009 includes 6 categories. To assess the sensitivity of the TI-RADS classification for diagnosing thyroid nodules. A retrospective study of all patients who underwent thyroidectomy at our hospital (n=263) from September 2013 to December 2015. After thyroidectomy, histological results were correlated to the ultrasound findings reported. Of the 263 study patients, 75 (28.5%) were diagnosed with thyroid cancer and 188 (71.5%) with benign disease. Correlation of histological results with preoperative ultrasound reports showed an initial sensitivity of 65%. After excluding 15 patients diagnosed with occult microcarcinoma, sensitivity increased to 81.6%. The ultrasound images from 11 false negatives cases were then reassessed by a radiologist who knew histological diagnosis and reclassified 10 of them as TI-RADS≥4. This procedure could have increased sensitivity up to 98.3%. Although the sensitivity initially found in our study using the TI-RADS scale was relatively low, the value markedly improved when patients with occult microcarcinoma were excluded. Thus, use of the TI-RADS scale would allow for an adequate selection of patients amenable to fine needle aspiration of the nodule. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Comparison of ultrasound, digital, and conventional radiography in differentiating periapical lesions: An in vivo study

    Directory of Open Access Journals (Sweden)

    Purnachandrarao Naik Nunsavathu

    2015-01-01

    Full Text Available Aims and Objectives: To evaluate in vivo the efficacy of ultrasound, digital and conventional radiography in identifying periapical lesions. To compare the results of the above imaging modalities with histopathology, which is considered to be the gold standard for diagnosis. Materials and Methods: Thirty patients aged between 15 and 45 years with periapical lesions associated with maxillary or mandibular anterior teeth indicated for endodontic surgery or extraction were selected for the study. Pre-operatively, conventional, digital periapical radiography and ultrasonography were done and interpreted. Endodontic surgery or extraction was performed including curettage of apical tissue to enable histopathological investigation, which provided the gold standard diagnosis. All measurements and findings were compared and statistically analyzed. Results: In conventional and digital radiography, the periapical lesions were readily identified but observers were unable to differentiate granuloma from cyst using these modalities only. But ultrasonography was able to give the true nature of the periapical pathology. All the cases diagnosed by ultrasound were confirmed with histopathology, and maximal number of cases diagnosed by ultrasound correlated with the histopathological diagnosis. Conclusion: The present study confirms that ultrasound is a promising and reliable imaging technique for differentiating periapical lesions i.e., periapical cysts and granulomas. Based on the echo texture of their contents and the presence of vascularity using color Doppler, periapical cyst and granulomas can be readily identified. The present study is further applicable for the evaluation of periapical lesions of the posterior teeth and evaluation of other jaw lesions.

  20. Hip Ultrasound

    Science.gov (United States)

    ... prior to the exam. Bringing books, small toys, music or games can help to distract the child and make the time ... back or side. Almost all of the ultrasound studies of infants and ... studied. The gel will help the transducer make secure contact with the body ...

  1. A Novel Method for Detection of Breast Microcalcifications Using Ultrasound-A Preliminary Study

    National Research Council Canada - National Science Library

    Boote, Evan

    2001-01-01

    .... If the capability to reliably detect microcalcifications with conventional ultrasound equipment did exist, the sensitivity and specificity of ultrasound imaging for the detection of early breast...

  2. A clinical and ultrasound study on the use of postplacental intrauterine device

    Directory of Open Access Journals (Sweden)

    João Henrique Araújo Fernandes

    2004-06-01

    Full Text Available Objective: To evaluate the relation of postplacental intrauterinedevice insertion immediately after vaginal delivery and cesareansection and its effects on the following: continuation, expulsionrate and eventual removals. To verify if ultrasound is an adequatemethod to follow-up postplacental IUD insertions. To assess if theimmediate insertion of postplacental IUD leads to an increasedrisk of uterine infections and perforations, or greater likelihood ofpregnancy during the observation period. Methods: A group of 50patients who had an intrauterine device introduced within tenminutes after delivery of the placenta were studied. Twenty-fivewomen had vaginal delivery and 25 had cesarean sections. Theintrauterine device used in this study was the Multiload CU 375,standard model, manufactured by Organon Ltd., in Ireland. Theintrauterine device was inserted in those who had vaginal deliveryeither manually and under anesthesia, or with an inserter, whichdid not require anesthesia. In patients who had cesarean sections,the insertion was manual. Clinical and ultrasound follow up wasperformed four times: 48 hours postpartum, and at 6, 12 and 24weeks. The distance from the top of the intrauterine device to theuterine fundus was measured by ultrasound. Results: This studyshowed a significant difference in postplacental intrauterinedevices inserted after vaginal deliveries and cesarean sections.The expulsion/removal rate was 32% among the subjects who hadan intrauterine device inserted after vaginal delivery. There wereno expulsions or removals in those submitted to cesarean sections.In the control ultrasound of intrauterine devices inserted aftervaginal delivery, at 6 weeks, the distance of 10 mm from the top ofthe device to the fundus was an average standard measurementto determine continuation (distance 10 mm,the IUD would be expelled or be removed. There were no cases ofuterine infections or perforations, and no pregnancies during thecourse of this study

  3. Intravascular haemolysis: a potential missed diagnosis.

    Science.gov (United States)

    Sinclair, David; Briston, Philip; Rutland, Emma

    2002-01-01

    Raised serum bilirubin is a common finding as part of a routine "liver function test" profile. This case describes a patient with a raised serum bilirubin that was eventually found to be caused by intravascular haemolysis. The tests that confirmed the cause were instigated by clinical biochemistry staff but not before the patient had undergone unnecessary invasive procedures and had the diagnosis delayed by some time. The case is a reminder to biochemistry and haematology laboratories and clinical staff to investigate the possibility of haemolysis as well as hepatitis and Gilbert's disease as a cause of an isolated raised bilirubin.

  4. Ultrasound assessment of umbilical venous catheter migration in preterm infants: a prospective study.

    Science.gov (United States)

    Franta, Jan; Harabor, Andrei; Soraisham, Amuchou S

    2017-05-01

    To evaluate the umbilical venous catheter (UVC) tip position by ultrasound and compare it with standard radiograph findings and to examine the catheter tip migration rates during the first week of life. Prospective observational study of inborn preterm infants who had an UVC placed and its position radiographically confirmed. The first ultrasound was done on UVC placement at median (IQR) age of 2 hours (1-4) and follow-up scans at a median (IQR) age of 34 hours (27-44 hours), 77 hours (70-94 hours) and 6 days (5-7 days) after insertion. Catheter tip was considered in optimum position if tip was lying in the inferior vena cava up to the right atrium opening. We studied 65 infants at a mean (±SD) gestational age and birth weight of 26.4 (±2.1) weeks and 808 (±289) g, respectively. Ultrasound confirmed optimum position of UVC tip in 25/65 (38.5%) infants. Majority (38/40) of the malpositioned catheters were located inside the heart with 15 reaching the left atrium. Catheter tip migration occurred in 29 of 58 infants (50%) at any time during the first week. The proportions of UVC migration were found to be 17%, 31% and 29% on subsequent ultrasound with a trend to outward movement over time. UVC tip localisation by standard radiography is very imprecise, and catheter tip migration occurs in a significant proportion of infants during first weeks of age. We suggest ultrasound as the best modality to assist localisation and follow-up of UVC tip in preterm infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Ultrasound Versus the Landmark Technique: A Prospective Randomized Comparative Study of Internal Jugular Vein Cannulation in an Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    B R Shrestha

    2011-06-01

    Full Text Available OBJECTIVE: The aim of this study is to find out if an ultrasound technique has advantages over the conventional landmark technique. METHODS: This is a prospective randomized comparative study on 120 patients requiring central venous cannulation of the right internal jugular vein. The study comprised of two groups: ultrasound and landmark groups, each consisting of 60 patients. The outcome measures were compared between the groups. RESULTS: Cannulation of the internal jugular vein was successful in 58 patients in the ultrasound group and in 53 in the landmark group. The number of attempts was 1.5 (1 - 3 and 2 (1 - 3 in the ultrasound and landmark group respectively (p = 0.001. The time taken for the successful cannulation was 4.9 +/- 1.7 minutes in the ultrasound approach and 8.0 +/- 2.8 minutes in the landmark approach (p = 0.00. The internal jugular vein diameter in the supine position was 11.2 +/- 1.5 mm which increased to 15.04 +/- 1.5 mm with a 15 degrees head-down position in the USG group (p = 0.001. The first attempt success rate was 39/60 (63% in the ultrasound group and 19/60 (32% with the landmark technique. The seven (12% failure cases in the landmark group were rescued by the ultrasound technique. Inadvertent carotid artery puncture occurred in 2/60 (3% and 6/60 (10% of patients in the ultrasound and land mark group respectively. CONCLUSIONS: Ultrasound improves success rate, minimizes cannulation time and complications during internal jugular vein cannulation. It can be employed as a rescue technique in cases of a failed landmark technique. Keywords:cannulation, central, landmark, technique, ultrasound.

  6. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  7. Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study

    Science.gov (United States)

    Besse, Stéphanie; Sarazin, Didier; Quinodoz, Pierre; Elias, Badwi; Safa, Marva; Vandeputte, Joan

    2017-01-01

    Background: This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection. Methods: One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed. Results: Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross. Conclusions: CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity. PMID:28280664

  8. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  9. Vascular applications of contrast-enhanced ultrasound imaging.

    Science.gov (United States)

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf A; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound is most often performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams ... to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . Ultrasound ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... What are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? In ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... What are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is ... in front of the rectum. top of page What are some common uses of the procedure? A ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  19. Physicians' experiences and views on the role of obstetric ultrasound in rural and urban Rwanda: a qualitative study.

    Science.gov (United States)

    Edvardsson, Kristina; Ntaganira, Joseph; Åhman, Annika; Sengoma, Jean Paul Semasaka; Small, Rhonda; Mogren, Ingrid

    2016-07-01

    To explore Rwandan physicians' experiences and views on the role of obstetric ultrasound in clinical management of pregnancy, and in situations where maternal and fetal health interests conflict. Physicians (n = 19) in public and private health facilities in urban and rural Rwanda were interviewed in 2015 as part of the CROss-Country Ultrasound Study (CROCUS). Data were analysed qualitatively. Ultrasound was described as an important tool in maternity care. Availability and quality of equipment varied across sites, and considerable disparities in obstetric ultrasound utilisation between rural and urban areas were described. The physicians wanted more ultrasound training and saw the potential for midwives to perform basic scans. Information about fetal sex and well-being was described as women's main expectations of ultrasound. Although women's right to autonomy in pregnancy was supported in principle by participating physicians, fetal rights were sometimes seen as needing physician 'protection'. There appears to be increasing use and demand for obstetric ultrasound in Rwanda, particularly in urban areas. It seems important to monitor this development closely to secure wise and fair allocation of scarce obstetric expertise and resources and to prevent overuse or misuse of ultrasound. Raising awareness about the benefits of all aspects of antenatal care, including ultrasound may be an important step to improve pregnant women's uptake of services. Increased opportunities for formal ultrasound training, including the training of midwives to perform basic scans, seem warranted. Moreover, in parallel with the transition to more medico-technical maternity care, a dialogue about maternal rights to autonomy in pregnancy and childbirth is imperative. © 2016 John Wiley & Sons Ltd.

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  1. Protection against high intravascular pressure in giraffe legs.

    Science.gov (United States)

    Petersen, Karin K; Hørlyck, Arne; Ostergaard, Kristine H; Andresen, Joergen; Broegger, Torbjoern; Skovgaard, Nini; Telinius, Niklas; Laher, Ismael; Bertelsen, Mads F; Grøndahl, Carsten; Smerup, Morten; Secher, Niels H; Brøndum, Emil; Hasenkam, John M; Wang, Tobias; Baandrup, Ulrik; Aalkjaer, Christian

    2013-11-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along the artery. Histology of the isolated median artery confirmed dense sympathetic innervation at the narrowing. Structure and contractility of small arteries from muscular beds in the leg and neck were compared. The arteries from the legs demonstrated an increased media thickness-to-lumen diameter ratio, increased media volume, and increased numbers of smooth muscle cells per segment length and furthermore, they contracted more strongly than arteries from the neck (500 ± 49 vs. 318 ± 43 mmHg; n = 6 legs and neck, respectively). Finally, the transient increase in interstitial fluid pressure following injection of saline was 5.5 ± 1.7 times larger (n = 8) in the leg than in the neck. We conclude that 1) tissue compliance in the legs is low; 2) large arteries of the legs function as resistance arteries; and 3) structural adaptation of small muscle arteries allows them to develop an extraordinary tension. All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure.

  2. VENOUS AIR-EMBOLISM, PRESERVATION REPERFUSION INJURY, AND THE PRESENCE OF INTRAVASCULAR AIR COLLECTIONS IN HUMAN DONOR LIVERS - A RETROSPECTIVE CLINICAL-STUDY

    NARCIS (Netherlands)

    WOLF, RFE; SLUITER, WJ; BALLAST, A; VANDAM, RM; SLOOFF, MJH

    In human liver transplantation, air embolism is seldom encountered after graft reperfusion. Nevertheless, despite adequate flushing and clamping routines, air emboli have been reported in transesophageal echocardiography (TEE) studies performed during the reperfusion phase, We retrospectively

  3. Comparison of ultrasound, digital, and conventional radiography in differentiating periapical lesions: An in vivo study

    OpenAIRE

    Purnachandrarao Naik Nunsavathu; Ravi Kiran Alaparthi; Samatha Yelamanchili; Neha Vashisht; Ravindra Naik Gugulothu; Sri Krishna Koppula

    2015-01-01

    Aims and Objectives: To evaluate in vivo the efficacy of ultrasound, digital and conventional radiography in identifying periapical lesions. To compare the results of the above imaging modalities with histopathology, which is considered to be the gold standard for diagnosis. Materials and Methods: Thirty patients aged between 15 and 45 years with periapical lesions associated with maxillary or mandibular anterior teeth indicated for endodontic surgery or extraction were selected for the study...

  4. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  5. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  6. Robust intravascular optical coherence elastography by line correlations

    International Nuclear Information System (INIS)

    Soest, Gijs van; Mastik, Frits; Jong, Nico de; Steen, Anton F W van der

    2007-01-01

    We present a new method for intravascular optical coherence elastography, which is robust against motion artefacts. It employs the correlation between adjacent lines, instead of subsequent frames. Pressure to deform the tissue is applied synchronously with the line scan rate of the optical coherence tomography (OCT) instrument. The viability of the method is demonstrated with a simulation study. We find that the root mean square (rms) error of the displacement estimate is 0.55 μm, and the rms error of the strain is 0.6%. It is shown that high-strain spots in the vessel wall, such as observed at the sites of vulnerable atherosclerotic lesions, can be detected with the technique

  7. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  8. An experimental system for the study of ultrasound exposure of isolated blood vessels

    Science.gov (United States)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-04-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels.

  9. Therapeutic ablation of the infrapatellar fat pad under ultrasound guidance: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    House, C.V. [Royal National Orthopaedic Hospital NHS Trust, Stanmore, Middlesex (United Kingdom)], E-mail: charles.house@uclh.nhs.uk; Connell, D.A. [Royal National Orthopaedic Hospital NHS Trust, Stanmore, Middlesex (United Kingdom)

    2007-12-15

    Aim: To describe the technique of ablation of the infrapatellar fat pad using alcohol injection under ultrasound guidance and to assess the efficacy of the procedure in the relief of pain arising from fat pad impingement. Material and Methods: Consecutive patients with anterior knee pain and pathology in the infrapatellar fat pad, confirmed on magnetic resonance imaging (MRI), were enrolled in the study. A mixture of alcohol and local anaesthetic was injected under ultrasound guidance, with repeat injections at three-weekly intervals. Twelve patients (seven men, five women), mean age 30.8 years, underwent the procedure. Visual analogue scale pain scores were recorded before treatment and at the end of the treatment course. Results: Before treatment, the mean ({+-}SD) pain score was 7.75 ({+-}1.14). Patients underwent a mean of four injections (range 2-6). After treatment, the mean pain score was 2.92 ({+-}2.61), representing a decrease of 62% (p < 0.001). Follow-up data were complete for all 12 patients. Other than short-lived pain at the time of injection, no serious side-effects were encountered. Conclusion: In patients with pain due to inflammation of the infrapatellar fat pad, ultrasound-guided alcohol ablation of the fat pad can provide effective symptom relief. The results of this pilot study indicate that a larger study is warranted to assess the long-term benefits of this well-tolerated procedure.

  10. Therapeutic ablation of the infrapatellar fat pad under ultrasound guidance: a pilot study

    International Nuclear Information System (INIS)

    House, C.V.; Connell, D.A.

    2007-01-01

    Aim: To describe the technique of ablation of the infrapatellar fat pad using alcohol injection under ultrasound guidance and to assess the efficacy of the procedure in the relief of pain arising from fat pad impingement. Material and Methods: Consecutive patients with anterior knee pain and pathology in the infrapatellar fat pad, confirmed on magnetic resonance imaging (MRI), were enrolled in the study. A mixture of alcohol and local anaesthetic was injected under ultrasound guidance, with repeat injections at three-weekly intervals. Twelve patients (seven men, five women), mean age 30.8 years, underwent the procedure. Visual analogue scale pain scores were recorded before treatment and at the end of the treatment course. Results: Before treatment, the mean (±SD) pain score was 7.75 (±1.14). Patients underwent a mean of four injections (range 2-6). After treatment, the mean pain score was 2.92 (±2.61), representing a decrease of 62% (p < 0.001). Follow-up data were complete for all 12 patients. Other than short-lived pain at the time of injection, no serious side-effects were encountered. Conclusion: In patients with pain due to inflammation of the infrapatellar fat pad, ultrasound-guided alcohol ablation of the fat pad can provide effective symptom relief. The results of this pilot study indicate that a larger study is warranted to assess the long-term benefits of this well-tolerated procedure

  11. Endoscopic ultrasound-guided ethanol ablation of pancreatic neuroendocrine tumours: A case study and literature review.

    Science.gov (United States)

    Armellini, Elia; Crinò, Stefano F; Ballarè, Marco; Pallio, Socrate; Occhipinti, Pietro

    2016-02-10

    Here we offer a review of the literature regarding endoscopic ultrasound-guided ethanol ablation for pancreatic neuroendocrine tumours and describe the case of a cystic tumour completely ablated after a multisession procedure. A total of 35 PubMed indexed cases of treated functioning and non-functioning pancreatic neuroendocrine tumours resulted from our search, 29 of which are well-documented and summarised. Endoscopic ultrasound-guided ethanol ablation appears as a local, minimally invasive treatment of pancreatic neuroendocrine tumours, suitable for selected patients. This technique appears feasible, relatively safe and efficient, especially when applied to symptom relief in functioning tumours, aiming at loss of endocrine secretion. For non-functioning tumours, where the goal is complete tissue ablation, eus guided ethanol ablation can provide good results for patients who are unfit for surgery or for those who refuse surgical resection. Its role in "fit for surgery" patients requires assessment through further studies.

  12. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    Energy Technology Data Exchange (ETDEWEB)

    Slapa, Rafal Z., E-mail: rz.slapa@gmail.com [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Kasperlik–Zaluska, Anna A. [Endocrinology Department, Center for Postgraduate Medical Education, Bielanski Hospital, Warsaw (Poland); Migda, Bartosz [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland); Otto, Maciej [Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, First Faculty of Medicine, Warsaw (Poland); Jakubowski, Wiesław S. [Diagnostic Imaging Department, Medical University of Warsaw, Second Faculty of Medicine with English and Physiotherapy Divisions, Warsaw (Poland)

    2015-08-15

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients.

  13. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas—Initial study

    International Nuclear Information System (INIS)

    Slapa, Rafal Z.; Kasperlik–Zaluska, Anna A.; Migda, Bartosz; Otto, Maciej; Jakubowski, Wiesław S.

    2015-01-01

    Highlights: • Adrenal masses may differ on parametric perfusion ultrasound. • Hyperplastic nodules present distinctive patterns on CEUS in regard to adenomas. • Adrenal lesions perfusion should be further investigated with different modalities. - Abstract: Objectives: To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. Patients and Methods: 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. Results: The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Conclusions: Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients

  14. MRI, PET/CT and ultrasound in the preoperative staging of endometrial cancer - a multicenter prospective comparative study

    DEFF Research Database (Denmark)

    Antonsen, Sofie Leisby; Jensen, Lisa Neerup; Tabor, Ann

    The aim of this prospective multicenter study was to evaluate and compare the diagnostic performance of PET/CT, MRI and transvaginal two-dimensional ultrasound (2DUS) in the preoperative assessment of endometrial cancer (EC).......The aim of this prospective multicenter study was to evaluate and compare the diagnostic performance of PET/CT, MRI and transvaginal two-dimensional ultrasound (2DUS) in the preoperative assessment of endometrial cancer (EC)....

  15. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  16. Transdermal drug delivery aided by an ultrasound contrast agent: an in vitro experimental study.

    Science.gov (United States)

    Park, Donghee; Yoon, Jinhee; Park, Jingam; Jung, Byungjo; Park, Hyunjin; Seo, Jongbum

    2010-02-11

    Sonophoresis temporarily increases skin permeability such that medicine can be delivered transdermally. Cavitation is believed to be the predominant mechanism in sonophoresis. In this study, an ultrasound contrast agent (UCA) strategy was adopted instead of low frequency ultrasound to assure that cavitation occurred, and the efficacy of sonophoresis with UCA was quantitatively analyzed by optical measurements. The target drug used in this study was 0.1 % Definity(R) in 70% glycerol, which was delivered into porcine skin samples. Glycerol was used because it is an optical clearing agent, and the efficiency of glycerol delivery could be analyzed with optical measurements. The applied acoustic pressure was approximately 600 kPa at 1 MHz ultrasound with a 10% duty cycle for 60 minutes. Experimental results indicated that the measured relative contrast (RC) after sonophoresis with UCA was approximately 80% higher than RC after sonophoresis without UCA. In addition, the variance of RC was also reduced by more than 50% with the addition of a UCA. The use of a UCA appeared to increase cavitation, demonstrating that the use of a UCA can be effective in transdermal drug delivery (TDD).

  17. The effect of smartphone addiction on hand joints in psoriatic patients: an ultrasound-based study.

    Science.gov (United States)

    Megna, M; Gisonni, P; Napolitano, M; Orabona, G Dell'Aversano; Patruno, C; Ayala, F; Balato, N

    2018-01-01

    Distal interphalangeal (DIP) arthritis is a frequent form of psoriatic arthritis being often linked to nail psoriasis. Modern society is characterized by overuse of smartphones. Indeed, literature has recently focalized on research into smartphone addiction and health-related problems. As smartphone addiction is able to determine overuse and repeated movements of DIP joints and nails, the aim of this study was to evaluate the impact of smartphone use on hand joints of young psoriatic patients. An observational study involving four different groups such as non-smartphone-addicted (SA) psoriatic patients, SA psoriatic patients, non-SA controls and SA controls was performed. Each subject underwent an ultrasound examination of both hands by three independent and blinded to group assignment radiologists. A specific score was used to evaluate the inflammatory state of the analysed joints. The total ultrasound score was statistically significantly higher in SA controls respect to non-SA controls (3.4 vs. 1.4; P Smartphone overuse was found to be linked with higher signs of inflammation of musculoskeletal structures of hands joints in both psoriasis and controls through ultrasound examination. Therefore, smartphone overuse may be a factor which facilitate or speed up the possible development of psoriatic arthritis. © 2017 European Academy of Dermatology and Venereology.

  18. Non-atherosclerotic spontaneous coronary artery dissection revascularized by intravascular ultrasonography-guided fenestration with cutting balloon angioplasty.

    Science.gov (United States)

    Ito, Tsuyoshi; Shintani, Yasuhiro; Ichihashi, Taku; Fujita, Hiroshi; Ohte, Nobuyuki

    2017-07-01

    A 46-year-old woman was referred to our hospital due to chest pain. Twelve-lead electrocardiogram revealed ST-segment elevation suggesting acute myocardial infarction. Emergent coronary angiography showed diffuse narrowing and occlusion in the middle to distal left anterior descending artery (LAD). To investigate the cause of occlusion, an intravascular ultrasound (IVUS) examination was performed and we diagnosed spontaneous coronary artery dissection (SCAD) as the cause of occlusion. After a cutting balloon was dilated at the distal LAD, coronary flow recovered. IVUS-guided angioplasty with cutting balloon could be a choice of treatment in SCAD patients who need revascularization.

  19. In vivo predictors of plaque erosion in patients with ST-segment elevation myocardial infarction: a clinical, angiographical, and intravascular optical coherence tomography study.

    Science.gov (United States)

    Dai, Jiannan; Xing, Lei; Jia, Haibo; Zhu, Yinchun; Zhang, Shaotao; Hu, Sining; Lin, Lin; Ma, Lijia; Liu, Huimin; Xu, Maoen; Ren, Xuefeng; Yu, Huai; Li, Lulu; Zou, Yanan; Zhang, Shaosong; Mintz, Gary S; Hou, Jingbo; Yu, Bo

    2018-03-13

    Plaque erosion is a significant substrate of acute coronary thrombosis. This study sought to determine in vivo predictors of plaque erosion in patients with ST-segment elevation myocardial infarction (STEMI). A prospective series of 822 STEMI patients underwent pre-intervention optical coherence tomography. Using established diagnostic criteria, 209 had plaque erosion (25.4%) and 564 had plaque rupture (68.6%). Plaque erosion was more frequent in women erosion were more frequently current smokers but had fewer other coronary risk factors (dyslipidaemia, hypertension, chronic kidney disease, and diabetes mellitus) than those with plaque rupture. There was a preponderance of plaque erosion in the left anterior descending artery (LAD; 61.2%), whereas plaque rupture was more equally distributed in both the LAD (47.0%) and right coronary artery (43.3%). Despite the similar spatial distribution of erosions and ruptures over the lengths of the coronary arteries, plaque erosion occurred more frequently near a bifurcation (P erosion. Nearby bifurcation and current smoking were especially notable in men, while age erosion was a predictable clinical entity distinct from plaque rupture in STEMI patients, and gender-specific role of risk factors in plaque erosion should be considered.

  20. Intravascular catheter-related bloodstream infection.

    Science.gov (United States)

    Shah, Harshal; Bosch, Wendelyn; Thompson, Kristine M; Hellinger, Walter C

    2013-07-01

    Intravascular catheters required for the care of many hospitalized patients can give rise to bloodstream infection, a complication of care that has occurred most frequently in intensive care unit (ICU) settings. Elucidation of the pathogenesis of catheter-related bloodstream infections (CRBSIs) has guided development of effective diagnostic, management, and prevention strategies. When CRBSIs occur in the ICU, physicians must be prepared to recognize and treat them. Prevention of these infections requires careful attention to optimal catheter selection, insertion and maintenance, and to removal of catheters when they are no longer needed. This review provides a succinct summary of the epidemiology, pathogenesis, and microbiology of CRBSIs and a review of current guidance for the diagnosis, management, and prevention of these infections.

  1. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  2. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  3. Chronic Disseminated Intravascular Coagulation: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Abul Kalam Azad

    2009-11-01

    Full Text Available In health there is a balance between the coagulation and anti-coagulation systems, but in disseminated intravascular coagulation (DIC the coagulation mechanism is activated inappropriately and in a diffuse way. This may lead to thrombosis, but more often haemorrhage occurs when the clotting factors are exhausted. DIC may present as acute, subacute, and rarely chronic form. Here we present a case of chronic DIC following pelvic inflammatory disease (PID as a consequence of repeated menstruation regulation (MR. We treated her with fresh frozen plasma, fresh blood, doxycycline with significant clinical improvement.DOI: 10.3329/bsmmuj.v1i1.3696 BSMMU J 2008; 1(1: 33-34

  4. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary bladder ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  8. Characteristics and Echogenicity of Clinical Ultrasound Contrast Agents: An In Vitro and In Vivo Comparison Study.

    Science.gov (United States)

    Hyvelin, Jean-Marc; Gaud, Emmanuel; Costa, Maria; Helbert, Alexandre; Bussat, Philippe; Bettinger, Thierry; Frinking, Peter

    2017-05-01

    To compare physicochemical characteristics and in vitro and in vivo contrast-enhanced ultrasound imaging performance of 3 commercially available ultrasound contrast agents: SonoVue (Bracco Imaging SpA, Colleretto Giacosa, Italy; also marketed as Lumason in the USA), Definity (Lantheus Medical Imaging, North Billerica, MA) and Optison (GE Healthcare AS, Oslo, Norway). Physicochemical characteristics were measured with a Multisizer Coulter Counter (Beckman Coulter, Fullerton, CA). Two ultrasound systems (Aplio 500; Toshiba Medical Systems Corp, Tochigi-ken, Japan; and Logiq E9; GE Healthcare, Little Chalfont, England) were used with different transducers. Contrast enhancement was measured in vitro by dose-ranging measurements using a custom-built beaker setup; in vivo imaging performances were compared in pigs (heart and liver) and rabbits (liver). Quantitative analyses were performed with VueBox quantification software (Bracco Suisse SA, Plan-les-Ouates, Switzerland). Measured physicochemical characteristics were in agreement with those provided by the manufacturers. In vitro data demonstrated that the performance of SonoVue was similar to or better than that of Definity but superior to Optison (normalized scattered power 2- to 10-fold higher with SonoVue). Similar results were obtained in vivo, although the duration of enhancement in the pig heart was longer for SonoVue compared to Definity, and quantitative analysis revealed higher enhancement for SonoVue (1.5-fold increase). For liver imaging, SonoVue and Definity showed similar contrast enhancement and duration of enhancement, but compared to Optison, both peak enhancement and duration of enhancement were superior for SonoVue (up to 2-fold increase). Imaging performance of SonoVue was similar to or slightly better than that of Definity, but it was superior to Optison for the conditions used in this study. © 2017 by the American Institute of Ultrasound in Medicine.

  9. Anatomy of the long head of biceps femoris: An ultrasound study.

    Science.gov (United States)

    Tosovic, D; Muirhead, J C; Brown, J M M; Woodley, S J

    2016-09-01

    Hamstring strains, particularly involving the long head of biceps femoris (BFlh) at the proximal musculotendinous junction (MTJ), are commonly experienced by athletes. With the use of diagnostic ultrasound increasing, an in-depth knowledge of normal ultrasonographic anatomy is fundamental to better understanding hamstring strain. The aim of this study was to describe the architecture of BFlh, using ultrasonography, in young men and cadaver specimens. BFlh morphology was examined in 19 healthy male participants (mean age 21.6 years) using ultrasound. Muscle, tendon and MTJ lengths were recorded and architectural parameters assessed at four standardised points along the muscle. Measurement accuracy was validated by ultrasound and dissection of BFlh in six male cadaver lower limbs (mean age 76 years). Intra-rater reliability of architectural parameters was examined for repeat scans, image analysis and dissection measurements. Distally the BFlh muscle had significantly (P anatomy of BFlh, which should be of assistance in analysing BFlh injury via imaging. Clin. Anat. 29:738-745, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. A temporal study of ultrasound contrast agent-induced changes in capillary density.

    Science.gov (United States)

    Johnson, Chenara A; Sarwate, Sandhya; Miller, Rita J; O'Brien, William D

    2010-09-01

    The ability of ultrasound (US) and ultrasound contrast agents (UCAs) to induce angiogenesis has been explored as a means of restoring blood flow to ischemic muscle. Because UCAs demonstrate an increasing percentage of collapse cavitation with increasing US pressure (Pr), this study sought to explore the effects of a US Pr that produces 100% collapse cavitation, determine the capillary density changes, and determine the time point of angiogenic rebound in a normal animal model. Using a 1-MHz focused transducer and a peak rarefactional US Pr of 3.8 MPa, rat gracilis muscles were exposed to US, and bioeffects were assessed. Capillary density, as a measure of angiogenesis, was examined. As an additional measure, inflammatory cells were quantified via a color threshold analysis to detect the presence of CD31 and CD34 as a percentage of the total section on stained slides. Six groups (0, 3, 6, 13, 20, and 27 days postexposure [DPE]; n = 3 each) and 5 cage controls were used to characterize the angiogenic response. Ultrasound-UCA treatment caused the capillary density to decrease acutely (0 DPE) by 70% and inflammatory cells to increase by up to 250%. The angiogenic rebound was observed at 3 DPE but did not return to control levels by 27 DPE, suggesting an incomplete healing response. Capillary destruction and inflammation played an important role in the angiogenic response induced by US-UCA. Exposure that causes 100% collapse cavitation causes capillary destruction from which normal rats are unable to recover and suggests a nontherapeutic effect.

  11. An Experimental Model Using Cultured Cardiac Myocytes for a Study of the Generation of Premature Ventricular Contractions Under Ultrasound Exposure

    Science.gov (United States)

    Kudo, Nobuki; Yamamoto, Masaya

    2011-09-01

    It is known that use of a contrast agents in echocardiography increases the probability of generation of premature ventricular contractions (PVCs). As a basic study to elucidate the mechanisms and to reduce adverse effects, the generation of PVCs was investigated using cultured cardiac myocytes instead of the intact heart in vivo. Cardiac myocytes were isolated from neonatal rats and cultured on a cover slip. The myocyte sample was exposed to pulsed ultrasound with microbubbles adjacent to the myocytes, and generation of PVCs was examined with ultrasound exposure at various delay times after onset of myocyte contraction. The experimental results showed that generation of PVCs had a stable threshold delay time and that PVCs were generated only when myocytes were exposed to ultrasound with delay times longer than the threshold. The results indicate that the model used in this study is useful for revealing the mechanisms by which PVCs are induced by ultrasound exposure.

  12. Ultrasound-based scores as predictors for nodular hyperplasia in patients with secondary hyperparathyroidism: a prospective validation study.

    Science.gov (United States)

    Gwiasda, Jill; Kaltenborn, Alexander; Müller, Jörg A; Serttas, Michaela; Scheumann, Georg W F; Schrem, Harald; Jäger, Mark D

    2017-03-01

    Former studies evaluated echostructural and vascular patterns in ultrasound of the parathyroid gland to identify nodular hyperplasia in patients with secondary hyperparathyroidism due to chronic kidney disease. This prospective study aims to externally validate suggested ultrasound classifications. Parathyroid glands of 27 patients with secondary hyperparathyroidism undergoing parathyroidectomy were prospectively analyzed. Ultrasound including Doppler imaging was performed 1 day prior to surgery. Ultrasound data were available for 70 parathyroid glands. Echostructural and vascular scores according to previous studies were applied calculating the area under the receiver operating characteristic curve (AUROC). Overall correctness, sensitivity, and specificity of the investigated scores were assessed with the Youden index method. The Doppler score introduced by Vulpio and colleagues based on characteristic blood flow patterns in parathyroid glands showed an AUROC of 0.749 for the prediction of nodular hyperplasia with an overall correctness of 72.8%. Other ultrasound classifications based on blood flow patterns, as well as echostructure of the parathyroid gland displayed AUROCs of secondary hyperparathyroidism was externally validated for the first time. Other ultrasound scores fail as prognostic models in this study population. Doppler sonography of the parathyroid gland has prognostic capability to identify nodular hyperplasia as surrogate marker for patients with secondary hyperparathyroidism indicating the need for ablative or surgical treatment when failing conservative therapy.

  13. ORIGINAL ARTICLES A contrast-enhanced ultrasound study of ...

    African Journals Online (AJOL)

    2008-04-21

    Apr 21, 2008 ... The diagnostic methods currently used to distinguish between benign and malignant breast lesions are all invasive and often inconclusive. This may lead to surgery for histological assessment.1 The main objective of this study was to determine the diagnostic accuracy of SonoVue (Bracco spa, Milan).

  14. Education and Propagation of Intravascular Surgery in Okinawa

    Science.gov (United States)

    Harakuni, T.; Hyodo, A.; Shingaki, T.; Kugai, M.; Kinjyo, T.; Kinjyo, T.; Tsuchida, H.; Sugimoto, K.; Yoshii, Y.

    2004-01-01

    Summary Okinawa is an island located on the southwest edge of the Japanese Islands in which about 1,300,000 people live, and is an area where self-conclusion type medical treatment is desired. In this area, intravascular surgery was only performed for several cases per year until 1998. From May 1999, intravascular surgery started being performed in earnest, and 140 or more cases of intravascular surgery per year were performed in 2002. In the meantime, various measures for the propagation and development of intravascular surgery that we undertook led to the increase in the number of cases. As a result, the choice of medical treatment has increased by propagating these medical treatments, and it seems that this has contributed to the welfare of the people of Okinawa. PMID:20587285

  15. Abdominal and pelvic ultrasound study of the maned wolf (Chrysocyon brachyurus

    Directory of Open Access Journals (Sweden)

    Luciana D. Guimarães

    2013-02-01

    Full Text Available The aim of the present study was the ultrasound characterization of the abdominal and pelvic regions of five maned wolves kept in captivity at the Triage Center of Wild Animals of the Federal University of Viçosa (Centro de Triagem de Animais Silvestres, Universidade Federal de Viçosa. This characterization included descriptions of ultrasonographic aspects and measurements of various structures using B-mode ultrasound. Biometric data were collected to assess the existence of significant linear correlations between these measurements and the measurements obtained by ultrasound. Additionally, hematological and serum biochemistry evaluations of the animals were performed. The ultrasound findings were similar to those available in the literature on domestic dogs, which were used for comparison as a result of the lack of published data regarding maned wolves. The latter species showed characteristics closely resembling those of the former, differing in the spleen and left renal cortex echogenicities, in the appearance of the prostatic and testicular regions and in the hepatic portal vein morphology. In the current study, the biometric values were similar to those previously published; however, no data regarding thoracic perimeter, modified crown-rump length or thoracic depth were found in the literature for this Canidae species. Statistical analysis showed the existence of a strong negative correlation between the modified crown-rump length and left renal length, between the modified crown-rump length and the right renal volume, between the thoracic perimeter and the height at the cranial pole of the left adrenal gland and between the thoracic perimeter and the height at the caudal pole of the left adrenal gland. Laboratory findings, including segmented neutrophil, eosinophil, monocyte and lymphocyte counts and the serum levels of glucose, ALT, alkaline phosphatase, urea, total protein, globulin, creatine phosphokinase, triglyceride, sodium

  16. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study

    Science.gov (United States)

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A.; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel

    2016-01-01

    Background and objectives Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. Design, setting, participants, & measurements In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound–guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre– and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Results Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Conclusions Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with

  17. Study on in-vessel ISI for JOYO. Ultrasound propagation characteristic in the core support plate

    International Nuclear Information System (INIS)

    Ariyoshi, Masahiko; Ara, Kuniaki; Hirabayashi, Masaru

    2005-03-01

    The report describes the feasibility study on the in-vessel inspection technique to be applied for the experimental fast reactor JOYO. The object of this examination is to confirm the integration of reactor structure under sodium environment by an immediate means. The core support plate which is an important structure supports the weight of the core assembly is selected to an object of the inspection. In the examination until last year, the core support plate inspection equipment concept which combined ultrasound sensor with manipulator was constructed. In this concept, the ultrasound sensor is accessed to a low-pressure plenum sidewall and integrity of the core support plate weld is inspected. In this study, the ultrasound propagation behavior was examined to confirm the range where the core support plate by this concept was able to be inspected. The outline result is shown follows. (1) Only the transverse wave can be generated in the structure material by reflecting the incidence longitudinal wave from the sensor in the wedge. The use of this transverse wave is effective in the core support plate inspection. (2) Because the attenuation of the ultrasound wave depends on the distance, the sensor is made to approach from the fuel rack in the reactor vessel about two places in the upper part of the core support plate weld far from low-pressure plenum. (3) It is necessary to evaluate the permeability of the ultrasound wave by the mock-up examination in consideration of a peculiar attenuation of the structural material, the reflectivity from defect, etc. (4) In the core support plate inspection of phenix reactor, a weld about 4m away from the sensor position is inspected by using the Lamb wave. In this inspection, because it was generated to echo according to the geometrical shape of the structure material, the evaluation method by the analysis to identify the echo from the defect was constructed, and it was verified by the mock-up examination. It is preferable that

  18. A 3D ultrasound study of sinus tract formation in hidradenitis suppurativa

    DEFF Research Database (Denmark)

    Wortsman, Ximena; Jemec, Gregor

    2013-01-01

    and characterization of the morphological changes in hidradenitis, which include the variable degrees of involvement of the hair follicles and the appearance of fluid collections and sinus tracts. Knowledge of this anatomical information may allow the identification of lesions that can benefit from medical or surgical......Imaging of hidradenitis suppurativa allows the study of both the lesion morphology and evolution. Hidradenitis lesions of different stages were studied using 3D ultrasound in a cross sectional pilot study. A total of 25 HS patients (18 female/ 7 male, aged 18-46 year-old) and 10 healthy controls (5...

  19. Prediction of postpercutaneous coronary intervention myocardial infarction: insights from intravascular imaging, coronary flow, and biomarker evaluation.

    Science.gov (United States)

    Hoole, Stephen P; Hernández-Sánchez, Jules; Brown, Adam J; Giblett, Joel P; Bennett, Martin R; West, Nick E J

    2018-05-01

    Percutaneous coronary intervention-induced myocardial infarction (PMI) has prognostic significance. Identifying patients at high risk for PMI is desirable as it may alter strategy and facilitate early preventative therapy. We therefore sought to establish whether preprocedural demographic, interventional (plaque characteristics and coronary microcirculatory function), and inflammatory, endothelial damage, and platelet-derived biomarker data could predict the risk of PMI. We performed target vessel pressure wire to assess fractional flow reserve, index of microcirculatory resistance (IMR) and coronary flow reserve, plaque characterization by virtual histology intravascular ultrasound, and assayed peripheral biomarkers before uncomplicated PCI in 88 patients. We then analyzed post-PCI cardiac troponin level to adjudicate PMI based on the third universal definition of myocardial infarction. Overall incidence of PMI was 27%. Women [10/15 (66%) vs. 14/73 (19%), PPMI. Preprocedural coronary flow reserve was lower in individuals with a subsequent PMI (1.8±1.2 vs. 2.1±1.3. P=0.03), and patients with higher pre-PCI IMR were more likely to sustain PMI [IMR>22: 10/23 (44%) vs. ≤22: 14/65 (22%), P=0.04], although neither was predictive after multivariate analysis. Plaque characterization by virtual histology intravascular ultrasound did not discriminate those at risk of PMI. However, peripheral venous interleukin (IL)-18 and IL-8 levels were independently negatively and positively associated with PMI, respectively. Women and those with low BMI, particularly when associated with high IL-8 and low IL-18 levels, appear to be at increased risk of PMI.

  20. Assessment of pelvic floor muscle contraction with palpation, perineometry and transperineal ultrasound: a cross-sectional study.

    Science.gov (United States)

    Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å

    2016-06-01

    To study the correlation between palpation, perineometry and transperineal ultrasound for assessment of pelvic floor muscle contraction and to define a contraction scale for ultrasound measurements. This was a cross-sectional study of 608 women examined with palpation of pelvic floor muscle contraction, using the Modified Oxford Scale, and measurement of the vaginal squeeze pressure with a vaginal balloon connected to a fiber-optic microtip transducer (perineometry). Transperineal ultrasound was used for measurements of levator hiatal area and anteroposterior (AP) diameter in the plane of minimal hiatal dimensions, at rest and on contraction. The pelvic floor muscle contraction was expressed as the percentage difference between values at rest and on contraction. Spearman's rank was used to test for correlation between the different methods of assessment. Significant correlations were found between all assessment methods (P 35% corresponded to strong contractions. We found moderate to strong correlation between ultrasound measurements, palpation and perineometry for assessing pelvic floor muscle contraction. The proportional change in levator hiatal AP diameter was the ultrasound measurement with strongest correlation to palpation and perineometry and formed the basis for the contraction scale for ultrasound measurements. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  1. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  2. Usefulness of high-frequency vascular ultrasound imaging and serum inflammatory markers to predict plaque rupture in patients with stable and unstable angina pectoris.

    Science.gov (United States)

    Chen, Wen Qiang; Zhang, Mei; Ji, Xiao Ping; Ding, Shi Fang; Zhao, Yu Xia; Chen, Yu Guo; Zhang, Cheng; Zhang, Yun

    2007-11-01

    It remains unclear what kind of morphologic and biochemical features best predict plaque rupture in patients with angina pectoris (AP). This study aimed to investigate whether combined high-frequency vascular ultrasound imaging and measurements of serum inflammatory biomarkers can predict coronary plaque ruptures in patients with AP. The study population consisted of 20 patients with stable AP and 40 patients with unstable AP. High-frequency vascular ultrasound imaging was performed in the 2 groups to measure intima-media thickness, the plaque acoustic density of the common carotid arteries, and the flow-mediated dilation of the brachial arteries. Serum lipid profile and inflammatory biomarkers were measured in all patients. Using intravascular ultrasound, a list of coronary imaging parameters was obtained. A multivariate logistic regression model was applied to calculate the odds ratio of each parameter to predict coronary plaque ruptures detected by intravascular ultrasound. Of 139 coronary artery plaques identified by intravascular ultrasound, 48 plaques (9 in stable AP and 39 in unstable AP) developed ruptures. Among measured parameters, the values of carotid intima-media thickness, coronary external elastic membrane area, plaque area, plaque burden, plaque eccentric index and remodeling index, serum high-sensitivity C-reactive protein, soluble intercellular adhesion molecule-1, and soluble vascular cell adhesion molecule-1 were significantly higher in unstable AP than in stable AP (p <0.05 to 0.01). Of these parameters, carotid intima-media thickness, serum high-sensitivity C-reactive protein, and the coronary remodeling index were found to be significant predictors of coronary plaque rupture, with odds ratios of 9.51 (95% confidence interval 1.29 to 21.81), 3.02 (95% confidence interval 1.01 to 7.65), and 0.01 (95% confidence interval 0.00 to 0.34), respectively. In conclusion, combined high-frequency ultrasound imaging of coronary and carotid arteries and

  3. Comparison of utility of blood cultures from intravascular catheters and peripheral veins: a systematic review and decision analysis.

    Science.gov (United States)

    Falagas, Matthew E; Kazantzi, Maria S; Bliziotis, Ioannis A

    2008-01-01

    Blood cultures are sometimes obtained from intravascular catheters for convenience. However, there is controversy regarding this practice. The authors compared the diagnostic test characteristics of blood cultures obtained from intravascular catheters and peripheral veins. Relevant studies for inclusion in this review were identified through PubMed (January 1970-October 2005) and the Cochrane Central Register of Controlled Trials. Studies that reported clear definitions of true bacteraemia were included in the analysis. Two reviewers independently extracted the data. Six studies were included in the analysis, providing data for 2677 pairs of blood cultures obtained from an intravascular catheter and a peripheral venipuncture. A culture obtained from an intravascular catheter was found to be a diagnostic test for bacteraemia with better sensitivity (OR 1.85, 95 % CI 1.14-2.99, fixed effects model) and better negative predictive value (almost with statistical significance) (OR 1.55, 95 % CI 0.999-2.39, fixed effects model) but with less specificity (OR 0.33, 95 % CI 0.18-0.59, random effects model) and lower positive predictive value (OR 0.41, 95 % CI 0.23-0.76, random effects model) compared to a culture taken by peripheral venipuncture. In a group of 1000 patients, eight additional patients with true bacteraemia would be identified and 59 falsely diagnosed as having bacteraemia by a blood culture obtained from an intravascular catheter compared to results of the peripheral blood culture. Given the consequences of undertreating patients with bacteraemia, the authors believe that, based on the available evidence, at least one blood culture should be obtained from the intravascular catheter.

  4. Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

    Energy Technology Data Exchange (ETDEWEB)

    Nabili, Marjan, E-mail: mnabili@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, 800 22nd Street NW, Room 5000, Washington, DC 20052 (United States); Geist, Craig, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu [Department of Ophthalmology, The George Washington University, 2150 Pennsylvania Avenue NW, Floor 2A, Washington, DC 20037 (United States); Zderic, Vesna, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu [Department of Biomedical Engineering, The George Washington University, 800 22nd Street NW, Room 6670, Washington, DC 20052 (United States)

    2015-10-15

    Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm{sup 2}, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm{sup 2} (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety

  5. Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

    International Nuclear Information System (INIS)

    Nabili, Marjan; Geist, Craig; Zderic, Vesna

    2015-01-01

    Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm 2 , and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm 2 (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this

  6. Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization?

    Directory of Open Access Journals (Sweden)

    Alistair Kent

    2015-01-01

    Full Text Available Introduction: Inferior vena cava collapsibility index (IVC-CI has been shown to correlate with both clinical and invasive assessment of intravascular volume status, but has important limitations such as the requirement for advanced sonographic skills, the degree of difficulty in obtaining those skills, and often challenging visualization of the IVC in the postoperative patient. The current study aims to explore the potential for using femoral (FV or internal jugular (IJV vein collapsibility as alternative sonographic options in the absence of adequate IVC visualization. Methods: A prospective, observational study comparing IVC-CI and Fem- and/or IJV-CI was performed in two intensive care units (ICU between January 2012 and April 2014. Concurrent M-mode measurements of IVC-CI and FV- and/or IJV-CI were collected during each sonographic session. Measurements of IVC were obtained using standard technique. IJV-CI and FV-CI were measured using high-frequency, linear array ultrasound probe placed in the corresponding anatomic areas. Paired data were analyzed using coefficient of correlation/determination and Bland-Altman determination of measurement bias. Results: We performed paired ultrasound examination of IVC-IJV (n = 39 and IVC-FV (n = 22, in 40 patients (mean age 54.1; 40% women. Both FV-CI and IJV-CI scans took less time to complete than IVC-CI scans (both, P < 0.02. Correlations between IVC-CI/FV-CI (R 2 = 0.41 and IVC-CI/IJV-CI (R 2 = 0.38 were weak. There was a mean -3.5% measurement bias between IVC-CI and IJV-CI, with trend toward overestimation for IJV-CI with increasing collapsibility. In contrast, FV-CI underestimated collapsibility by approximately 3.8% across the measured collapsibility range. Conclusion: Despite small measurement biases, correlations between IVC-CI and FV-/IJV-CI are weak. These results indicate that IJ-CI and FV-CI should not be used as a primary intravascular volume assessment tool for clinical decision support in

  7. Numerical study of thermoviscous effects in ultrasound-induced acoustic streaming in microchannels

    DEFF Research Database (Denmark)

    Muller, Peter Barkholt; Bruus, Henrik

    2014-01-01

    We present a numerical study of thermoviscous effects on the acoustic streaming flow generated by an ultrasound standing-wave resonance in a long straight microfluidic channel containing a Newtonian fluid. These effects enter primarily through the temperature and density dependence of the fluid...... viscosity. The resulting magnitude of the streaming flow is calculated and characterized numerically, and we find that even for thin acoustic boundary layers, the channel height affects the magnitude of the streaming flow. For the special case of a sufficiently large channel height, we have successfully...

  8. [Intravascular lymphomatosis. A report of three cases].

    Science.gov (United States)

    Menéndez Calderón, M J; Seguí Riesco, M E; Argüelles, M; Nuño Mateo, J

    2005-01-01

    Intravascular lymphomatosis (IVL) is a rare malignancy characterized by a proliferation of atypical lymphoid cells occluding small blood vessels (venules, capillaries and small arteries). The symptoms are caused by embolisms due to massive proliferation. Nervous system and skin are the most common sites of involvement but all organs may be involved, although it is typified by the absence of malignant cells in lymphoid tissues. We describe three cases of IVL: first patient was a 57 years old man with rapidly progressive dementia and neurological involvements and second case of a 69 years old man hospitalised with predominant symptoms in the lung (cough, dyspnea and fever), and a woman presenting as fever of unknown origin (FUO) with systemic inflammatory response syndrome. In all cases that we reported have been diagnosed post-mortem because of rapid progression of a multisystem disease and the absence of pathognomonic clinical manifestations. Diagnosis can be made using biopsy of one of the involved organs. In conclusion, we propose that IVL should be included in the differential diagnosis of acute confusional state, dementia or other unexplained neurological manifestations, fever of unknown origin, vasculitis, occult neoplasia or infections with signs of a systemic disease and marked elevation of serum lactate dehydrogenase (LDH).

  9. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help ... tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Your child should wear loose, comfortable clothing and may be asked to wear a gown. What is ... within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound examination. ...

  12. Sonophoresis using ultrasound contrast agents for transdermal drug delivery: an in vivo experimental study.

    Science.gov (United States)

    Park, Donghee; Ryu, Heungil; Kim, Han Sung; Kim, Young-Sun; Choi, Kyu-Sil; Park, Hyunjin; Seo, Jongbum

    2012-04-01

    Sonophoresis temporally increases skin permeability such that various medications can be delivered noninvasively. Previous sonophoresis studies have suggested that cavitation plays an important role in enhancing transdermal drug delivery (TDD). In this study, the feasibility of controlled cavitation using ultrasound contrast agents (UCAs) at high frequency was explored through in vivo experiments in a rat model. Two commercially available UCAs, SonoVue® and Definity®, were used at 2.47 MHz and 1.12 MHz, respectively. Fluorescein isothiocyanate (FITC)-dextran with 0.1% UCA was used as the drug to be delivered through the skin. Ultrasound with a 10 ms pulse and a 1% duty cycle at 1 MPa acoustic pressure for 30 min was applied in all sonication sessions. The efficacy of sonophoresis with UCAs was quantitatively analyzed using an optical imaging system that was used to count photons emitted from fluorescein. The results showed that the proposed sonophoresis method significantly improved drug penetration compared with the traditional sonophoresis method with 4 kD, 20 kD and 150 kD FITC-dextrans at 1.12 MHz, and with 4 kD and 20 kD FITC-dextrans at 2.47 MHz. Sonophoresis for TDD was performed more effectively with the aid of UCAs. Sonophoresis with UCAs has excellent potential for broad applications in drug delivery for diseases requiring the chronic administration of medications such as diabetes. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Contrast-enhanced ultrasound in portal venous system aneurysms: A multi-center study

    Science.gov (United States)

    Tana, Claudio; Dietrich, Christoph F; Badea, Radu; Chiorean, Liliana; Carrieri, Vincenzo; Schiavone, Cosima

    2014-01-01

    AIM: To investigate contrast-enhanced ultrasound (CEUS) findings in portal venous system aneurysms (PVSAs). METHODS: In this multi-center, retrospective, case series study, we evaluated CEUS features of seven cases of PVSAs that were found incidentally on conventional ultrasound in the period 2007-2013. Three Ultrasound Centers were involved (Chieti, Italy, Bad Mergentheim, Germany, and Cluj-Napoca, Romania). All patients underwent CEUS with Sonovue® (Bracco, Milan, Italy) at a standard dose of 2.4 mL, followed by 10 mL of 0.9% saline solution. The examinations were performed using multifrequency transducers and low mechanical index. We considered aneurysmal a focal dilatation of the portal venous system with a size that was significantly greater than the remaining segments of the same vein, and that was equal or larger than 21 mm for the extrahepatic segments of portal venous system, main portal vein and bifurcation, and 9 mm for the intrahepatic branches. RESULTS: After contrast agent injection, all PVSAs were not enhanced in the arterial phase (starting 8-22 s). All PVSAs were then rapidly enhanced in the early portal venous phase (starting three to five seconds after the arterial phase, 11-30 s), with persistence and slow washout of the contrast agent in the late phase (starting 120 s). In all patients, CEUS confirmed the presence of a “to-and-fro” flow by showing a swirling pattern within the dilatation in the early portal venous phase. CEUS also improved the delineation of the lumen, and was reliable in showing its patency degree and integrity of walls. In one patient, CEUS showed a partial enhancement of the lumen with a uniformly nonenhancing area in the portal venous and late phases, suggesting thrombosis. CONCLUSION: In our case series, we found that CEUS could be useful in the assessment and follow-up of a PVSA. Further studies are needed to validate its diagnostic accuracy. PMID:25561805

  14. Improving the statistics of quantitative ultrasound techniques with deformation compounding: an experimental study.

    Science.gov (United States)

    Herd, Maria-Teresa; Hall, Timothy J; Jiang, Jingfeng; Zagzebski, James A

    2011-12-01

    Many quantitative ultrasound (QUS) techniques are based on estimates of the radio-frequency (RF) echo signal power spectrum. Historically, reliable spectral estimates required spatial averaging over large regions-of-interest (ROIs). Spatial compounding techniques have been used to obtain robust spectral estimates for data acquired over small regions of interest. A new technique referred to as "deformation compounding" is another method for providing robust spectral estimates over smaller regions of interest. Motion tracking software is used to follow an ROI while the tissue is deformed (typically by pressing with the transducer). The deformation spatially reorganizes the scatterers so that the resulting echo signal is decorrelated. The RF echo signal power spectrum for the ROI is then averaged over several frames of RF echo data as the tissue is deformed, thus, undergoing deformation compounding. More specifically, averaging spectral estimates among the uncorrelated RF data acquired following small deformations allows reduction in the variance of the power spectral density estimates and, thereby, improves accuracy of spectrum-based tissue property estimation. The viability of deformation compounding has been studied using phantoms with known attenuation and backscatter coefficients. Data from these phantoms demonstrates that a deformation of about 2% frame-to-frame average strain is sufficient to obtain statistically-independent echo signals (with correlations of less than 0.2). Averaging five such frames, where local scatterer reorganization has taken place due to mechanical deformations, reduces the average percent standard deviation among power spectra by 26% and averaging 10 frames reduces the average percent standard deviation by 49%. Deformation compounding is used in this study to improve measurements of backscatter coefficients. These tests show deformation compounding is a promising method to improve the accuracy of spectrum-based quantitative ultrasound

  15. Preoperative imaging for DIEA perforator flaps: a comparative study of computed tomographic angiography and Doppler ultrasound.

    Science.gov (United States)

    Rozen, Warren M; Phillips, Timothy J; Ashton, Mark W; Stella, Damien L; Gibson, Robert N; Taylor, G Ian

    2008-01-01

    Abdominal donor-site flaps, including the transverse rectus abdominis musculocutaneous (TRAM) and deep inferior epigastric artery (DIEA) perforator flaps, are standard in autologous breast reconstruction. With significant variation in the vascular anatomy of the abdominal wall, preoperative imaging is essential for preoperative planning and reducing intraoperative error. Doppler and color duplex sonography have been used with varying results, and the quest continues for optimal preoperative assessment. Computed tomographic angiography has recently been proposed as a noninvasive modality for this purpose. This is the first study to formally compare preoperative Doppler ultrasound with computed tomographic angiography for imaging the DIEA. Eight consecutive patients undergoing DIEA perforator flap surgery for breast reconstruction underwent both computed tomographic angiography and Doppler ultrasound preoperatively. All investigations and procedures were performed at the same institution with the same primary and assisting surgeons and the same radiology team. Computed tomographic angiography was superior to Doppler ultrasound at identifying the course of the DIEA and its branching pattern, and in visualizing its perforators. Preoperative computed tomographic angiography was highly specific (100 percent) and more sensitive in mapping and visualizing perforators (p = 0.0078). It was also proficient at identifying the superficial epigastric arterial system and for effectively displaying the results intraoperatively. It was substantially quicker and removed the interobserver error associated with Doppler ultrasonography. The study was ceased after eight patients because of the overwhelming benefit of computed tomographic angiography over Doppler ultrasonography. Computed tomographic angiography is a valuable imaging modality for the preoperative assessment of the donor-site vascular supply for TRAM and DIEA perforator flaps.

  16. Abnormal cervical lymph nodes in multiple sclerosis: a preliminary ultrasound study.

    Science.gov (United States)

    Di Giuliano, Francesca; Albanese, Maria; Picchi, Eliseo; Mori, Francesco; Buttari, Fabio; Marfia, Girolama Alessandra; Garaci, Francesco; Mercuri, Nicola Biagio; Floris, Roberto; Centonze, Diego; Marziali, Simone

    2018-03-01

    Cervical lymph nodes are the first drainage stations of the brain and therefore play a key role in neuroinflammatory disorders such as multiple sclerosis. The aim of this study was to evaluate, by using ultrasound imaging, cervical lymph nodes in patients with multiple sclerosis and to ascertain if such patients have any clinical features to attest their role. We enrolled 43 patients affected by relapsing-remitting multiple sclerosis (22 drug free and 21 under treatment with natalizumab or fingolimod), who underwent ultrasound examination. The morphology, diameters and volume of cervical lymph nodes were measured. We evaluated also a control group of 20 healthy volunteers. Between-group comparisons showed that the mean anteroposterior diameters in the cervical lymph nodes on both sides of the neck were significantly different (χ 2  = 19.5, p < 0.001 for right; χ 2  = 20.0, p < 0.001 for left). Post hoc contrasts showed that the mean anteroposterior diameters were greater both in drug-naive (mean ± SD 0.66 ± 0.20 cm; p < 0.001) and treated patients (0.55 ± 0.24 cm; p < 0.001) compared to healthy individuals (0.36 ± 0.19 cm). Moreover, significant difference (p < 0.001) was shown on comparing the mean volume of the cervical lymph nodes on both sides of the neck in the studied groups. No significant differences emerged between the drug-free and treated patients. The abnormalities shown by ultrasound in cervical lymph nodes are related to deep ones and independent of the ongoing treatment, suggesting a relationship between lymphatic drainage and disease pathology.

  17. EX VIVO STUDY OF QUANTITATIVE ULTRASOUND PARAMETERS IN FATTY RABBIT LIVERS

    Science.gov (United States)

    Ghoshal, Goutam; Lavarello, Roberto J.; Kemmerer, Jeremy P.; Miller, Rita J.; Oelze, Michael L.

    2012-01-01

    Nonalcoholic fatty liver disease (NAFLD) affects more than 30% of Americans, and with increasing problems of obesity in the United States, NAFLD is poised to become an even more serious medical concern. At present, accurate classification of steatosis (fatty liver) represents a significant challenge. In this study, the use of high-frequency (8 to 25 MHz) quantitative ultrasound (QUS) imaging to quantify fatty liver was explored. QUS is an imaging technique that can be used to quantify properties of tissue giving rise to scattered ultrasound. The changes in the ultrasound properties of livers in rabbits undergoing atherogenic diets of varying durations were investigated using QUS. Rabbits were placed on a special fatty diet for 0, 3, or 6 weeks. The fattiness of the livers was quantified by estimating the total lipid content of the livers. Ultrasonic properties, such as speed of sound, attenuation, and backscatter coefficients, were estimated in ex vivo rabbit liver samples from animals that had been on the diet for varying periods. Two QUS parameters were estimated based on the backscatter coefficient: effective scatterer diameter (ESD) and effective acoustic concentration (EAC), using a spherical Gaussian scattering model. Two parameters were estimated based on the backscattered envelope statistics (the k parameter and the μ parameter) according to the homodyned K distribution. The speed of sound decreased from 1574 to 1565 m/s and the attenuation coefficient increased from 0.71 to 1.27 dB/cm/MHz, respectively, with increasing fat content in the liver. The ESD decreased from 31 to 17 μm and the EAC increased from 38 to 63 dB/cm3 with increasing fat content in the liver. A significant increase in the μ parameter from 0.18 to 0.93 scatterers/mm3 was observed with increasing fat content in the liver samples. The results of this study indicate that QUS parameters are sensitive to fat content in the liver. PMID:23062376

  18. Comparison Between the Polymyxins and Gentamicin in Preventing Endotoxin-Induced Intravascular Coagulation and Leukopenia

    Science.gov (United States)

    Corrigan, James J.; Bell, Bobbie M.

    1971-01-01

    Three antimicrobial agents were evaluated as to their ability to neutralize the toxic effects of endotoxin in rabbits. These consisted of two cyclic polypeptides, polymyxin B sulfate and colymycin M (sodium colistimethate), and an aminoglycoside, gentamicin sulfate. Polymyxin B regularly prevented endotoxin-induced leukopenia, thrombocytopenia, and disseminated intravascular coagulation. Colymycin M had similar activity but was not as effective as polymyxin B. Gentamicin demonstrated no neutralizing ability in this study. PMID:4343409

  19. Distribution of [35S] taurine in mouse retina after intravitreal and intravascular injection

    International Nuclear Information System (INIS)

    Pourcho, R.G.

    1977-01-01

    The distribution of [ 35 S] taurine in mouse retinae was studied by autoradiographic techniques after either intravitreal or intravascular injection. The route of injection did not affect the final localization. The major sites of label accumulation were the outer nuclear layer, the inner nuclear layer, and Mueller cell processes adjacent to the vitreal surface. The distribution was consistent with the interpretation that taurine was localized within two cellular compartments of mouse retina, photoreceptor cells and Mueller cells. (author)

  20. Intravascular versus surface cooling for targeted temperature management after out-of-hospital cardiac arrest

    DEFF Research Database (Denmark)

    Glover, Guy W; Thomas, Richard M; Vamvakas, George

    2016-01-01

    BACKGROUND: Targeted temperature management is recommended after out-of-hospital cardiac arrest and may be achieved using a variety of cooling devices. This study was conducted to explore the performance and outcomes for intravascular versus surface devices for targeted temperature management after...... out-of-hospital cardiac arrest. METHOD: A retrospective analysis of data from the Targeted Temperature Management trial. N = 934. A total of 240 patients (26%) managed with intravascular versus 694 (74%) with surface devices. Devices were assessed for speed and precision during the induction......, maintenance and rewarming phases in addition to adverse events. All-cause mortality, as well as a composite of poor neurological function or death, as evaluated by the Cerebral Performance Category and modified Rankin scale were analysed. RESULTS: For patients managed at 33 °C there was no difference between...

  1. Application of parametric ultrasound contrast agent perfusion studies for differentiation of hyperplastic adrenal nodules from adenomas-Initial study.

    Science.gov (United States)

    Slapa, Rafal Z; Kasperlik-Zaluska, Anna A; Migda, Bartosz; Otto, Maciej; Jakubowski, Wiesław S

    2015-08-01

    To evaluate the possibilities of differentiation of non-malignant adrenal masses with the application of the new technique for the evaluation of enhancement after administration of an ultrasound contrast agent: parametric imaging. 34 non-malignant adrenal masses in 29 patients were evaluated in a dynamic examination after the administration of ultrasound contrast agent with parametric imaging. Patterns on parametric imaging of arrival time were evaluated. The final diagnosis was based on CT, MRI, biochemical studies, follow up and/or histopathology examination. The study included: 12 adenomas, 10 hyperplastic nodules, 7 myelolipomas, 3 pheochromocytomas, hemangioma with hemorrhage and cyst. The pattern of peripheral laminar inflow of Sonovue on parametric images of arrival time of was 100% sensitive for hyperplastic nodules and 83% specific in regard to adenomas. Parametric contrast enhanced ultrasound may accurately differentiate hyperplastic adrenal nodules from adenomas and could be complementary to CT or MRI. Incorporation of perfusion studies to CT or MRI could possibly enable one-shop complete characterization of adrenal masses. This could deliver additional information in diagnostics of patients with Conn Syndrome and warrants further studies in this cohort of patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Magnetic Resonance-Guided High-Intensity-Focused Ultrasound for Palliation of Painful Skeletal Metastases: A Pilot Study.

    Science.gov (United States)

    Chan, Michael; Dennis, Kristopher; Huang, Yuexi; Mougenot, Charles; Chow, Edward; DeAngelis, Carlo; Coccagna, Jennifer; Sahgal, Arjun; Hynynen, Kullervo; Czarnota, Gregory; Chu, William

    2017-10-01

    Bone is one of the most common sites of metastases, with bone metastases-related pain representing a significant source of morbidity among patients with cancer. Magnetic resonance-guided focused ultrasound is a noninvasive, outpatient modality with the potential for treating painful bone metastases. The aim of this study is to report our initial experience with magnetic resonance-guided focused ultrasound in the treatment of bone metastases and our preliminary analysis of urinary cytokine levels after therapy. This was a single-center pilot study of 10 patients with metastatic cancer to investigate the feasibility of magnetic resonance-guided focused ultrasound for primary pain control in device-accessible skeletal metastases. Treatments were performed on a clinical magnetic resonance-guided focused ultrasound system using a volumetric ablation technique. Primary efficacy was assessed using Brief Pain Inventory scores and morphine equivalent daily dose intake at 3 time points: before, day 14, and day 30 after the magnetic resonance-guided focused ultrasound treatment. Urine cytokines were measured 3 days before treatment and 2 days after the treatment. Of the 10 patients, 8 were followed up 14 days and 6 were followed up 30 days after the treatment. At day 14, 3 patients (37.5%) exhibited partial pain response and 4 patients (50%) exhibited an indeterminate response, and at day 30 after the treatment, 5 patients (83%) exhibited partial pain response. No treatment-related adverse events were recorded. Of the urine cytokines measured, only Transforming growth factor alpha (TGFα) demonstrated an overall decrease, with a trend toward statistical significance ( P = .078). Our study corroborates magnetic resonance-guided focused ultrasound as a feasible and safe modality as a primary, palliative treatment for painful bone metastases and contributes to the limited body of literature using magnetic resonance-guided focused ultrasound for this clinical indication.

  3. Third-molar extraction with ultrasound bone surgery: a case-control study.

    Science.gov (United States)

    Mozzati, Marco; Gallesio, Giorgia; Russo, Andrea; Staiti, Giorgio; Mortellaro, Carmen

    2014-05-01

    The aim of this case-control study was to evaluate the postoperative period and healing between 2 surgical methods (traditional and ultrasound bone surgery) that are used for mandibular third-molar extraction. Fifteen patients with impaction of both of the lower third molars and indications for their extractions were used in this study. Bilateral-mandibular third-molar extractions were performed at the same surgical time: traditional surgery with burrs was used on 1 side (control site), and ultrasound surgery was used on the other side (test [T] site). After surgery, the patients were examined at 7 and 14 days and at 1 and 3 months to evaluate tissue healing. The following was assessed at every follow-up: pain, trismus, swelling, and alveolar bone level. The study included 15 patients, and 30 mandibular third-molar extractions were performed. We found only 1 postoperative complication: 1 patient had alveolitis in the control site. Complete recoveries without any complications were reported in all of the patients at the T sites. Complete recoveries without any complication were reported in all patients at the T sites. The only disadvantage of the piezoelectric technique was the length of operation time, which was increased by approximately 8 minutes; however, this effect was offset by reducing the morbidity. Our preliminary study showed that Piezosurgery is an excellent tool for reducing the risk of complications and improving the postoperative period.

  4. Enhanced-MRI and ultrasound evaluation of painful shoulder in patients after stroke: a pilot study.

    Science.gov (United States)

    Pompa, Alessandra; Clemenzi, Alessandro; Troisi, Elio; Di Mario, Marco; Tonini, Angelo; Pace, Luca; Casillo, Paolo; Cuccaro, Alessandro; Grasso, Maria Grazia

    2011-01-01

    Epidemiological and radiological studies have previously been performed to identify the possible causes of hemiplegic shoulder pain (HSP). Many different etiologies have been postulated, though no clear correlations have emerged, and a multifactorial pathogenesis of HSP has been proposed. Recently, two MRI-based studies have described different shoulder findings as possible causes of pain in chronic stroke survivors. The aim of this study was to describe the structural abnormalities of the painful shoulder in the first months after stroke by ultrasound and enhanced MRI. The secondary aims were to identify possible predisposing factors for HSP and to evaluate its impact on motor recovery. One hundred and fifty-three first-time stroke patients, admitted to the Santa Lucia Foundation for rehabilitation, were investigated for HSP. Twenty-five stroke patients with HSP and 16 stroke patients without shoulder pain were included. An ultrasound evaluation and enhanced shoulder MRI were performed for all the patients. Among the shoulder abnormalities detected by both imaging studies, only capsulitis, which was detected by enhanced shoulder MRI in 88% of the HSP patients, was independently associated with pain (p pain intensity as expressed by the VAS score (p pain. Adhesive capsulitis was found to be a possible cause of HSP. However, MRI, which is more expensive than other diagnostic tools, may be considered the gold standard tool for understanding the etiology of HSP. Copyright © 2011 S. Karger AG, Basel.

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams are also used to ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic pain abnormal ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... your knees toward your chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... right in front of the rectum. top of page What are some common uses of the procedure? A ... ultrasound to clean out the bowel. top of page What does the equipment look like? Ultrasound scanners consist ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a finger – is ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of ... show up well on x-ray images. Ultrasound causes no health problems and may be repeated as ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Transvaginal ultrasound is performed very much like a gynecologic exam and involves the insertion of the transducer ... with your feet in stirrups similar to a gynecologic exam. Transrectal: For a transrectal ultrasound, a protective ...

  18. Advanced noise reduction in placental ultrasound imaging using CPU and GPU: a comparative study

    Science.gov (United States)

    Zombori, G.; Ryan, J.; McAuliffe, F.; Rainford, L.; Moran, M.; Brennan, P.

    2010-03-01

    This paper presents a comparison of different implementations of 3D anisotropic diffusion speckle noise reduction technique on ultrasound images. In this project we are developing a novel volumetric calcification assessment metric for the placenta, and providing a software tool for this purpose. The tool can also automatically segment and visualize (in 3D) ultrasound data. One of the first steps when developing such a tool is to find a fast and efficient way to eliminate speckle noise. Previous works on this topic by Duan, Q. [1] and Sun, Q. [2] have proven that the 3D noise reducing anisotropic diffusion (3D SRAD) method shows exceptional performance in enhancing ultrasound images for object segmentation. Therefore we have implemented this method in our software application and performed a comparative study on the different variants in terms of performance and computation time. To increase processing speed it was necessary to utilize the full potential of current state of the art Graphics Processing Units (GPUs). Our 3D datasets are represented in a spherical volume format. With the aim of 2D slice visualization and segmentation, a "scan conversion" or "slice-reconstruction" step is needed, which includes coordinate transformation from spherical to Cartesian, re-sampling of the volume and interpolation. Combining the noise filtering and slice reconstruction in one process on the GPU, we can achieve close to real-time operation on high quality data sets without the need for down-sampling or reducing image quality. For the GPU programming OpenCL language was used. Therefore the presented solution is fully portable.

  19. The diagnostic performance of ultrasound for acute appendicitis in pregnant and young nonpregnant women: A case-control study.

    Science.gov (United States)

    Segev, Lior; Segev, Yakir; Rayman, Shlomi; Nissan, Aviram; Sadot, Eran

    2016-10-01

    Ultrasonography is frequently used to diagnose acute appendicitis in women of reproductive age, but its diagnostic value in pregnant patients remains unclear. This study sought to compare the diagnostic performance of ultrasound in pregnant and young nonpregnant women with suspected acute appendicitis. The database of a single tertiary medical center was reviewed for all women of reproductive age who underwent appendectomy either during pregnancy (2000-2014) or in the nonpregnant state (2004-2007) following ultrasound evaluation. The performance of ultrasound in terms of predicting the final pathologic diagnosis was compared between the pregnant and non pregnant groups using receiver operating characteristic curve analysis. Of 586 young women treated for appendicitis during the study periods (92 pregnant, 494 non-pregnant), 200 underwent preoperative ultrasound [67 pregnant, and 133 nonpregnant young women]. The pregnant and nonpregnant groups were comparable in age and presenting symptoms. There was no significant difference in the predictive performance of ultrasound between the two groups (AUC 0.76 and 0.73 respectively, p = 0.78) or within the pregnant group, by trimester [first (n = 23), AUC 0.73; second (n = 32), AUC 0.67; third (n = 12), AUC 0.86; p = 0.4]. Ultrasound had a positive predictive value of 0.94 in the pregnant group and 0.91 in the nonpregnant group; corresponding negative predictive values were 0.40 and 0.43. There appears to be no difference in the ability of ultrasound to predict the diagnosis of acute appendicitis between pregnant women and nonpregnant women of reproductive age. Therefore, similar preoperative imaging algorithms may be used in both patient populations. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. High-Intensity Focused Ultrasound (HIFU) in Uterine Fibroid Treatment: Review Study

    International Nuclear Information System (INIS)

    Mahmoud, Mustafa Z.; Alkhorayef, Mohammed; Alzimami, Khalid S.; Aljuhani, Manal Saud; Sulieman, Abdelmoneim

    2014-01-01

    High-intensity focused ultrasound (HIFU) is a highly precise medical procedure used locally to heat and destroy diseased tissue through ablation. This study intended to review HIFU in uterine fibroid therapy, to evaluate the role of HIFU in the therapy of leiomyomas as well as to review the actual clinical activities in this field including efficacy and safety measures beside the published clinical literature. An inclusive literature review was carried out in order to review the scientific foundation, and how it resulted in the development of extracorporeal distinct devices. Studies addressing HIFU in leiomyomas were identified from a search of the Internet scientific databases. The analysis of literature was limited to journal articles written in English and published between 2000 and 2013. In current gynecologic oncology, HIFU is used clinically in the treatment of leiomyomas. Clinical research on HIFU therapy for leiomyomas began in the 1990s, and the majority of patients with leiomyomas were treated predominantly with HIFUNIT 9000 and prototype single focus ultrasound devices. HIFU is a non-invasive and highly effective standard treatment with a large indication range for all sizes of leiomyomas, associated with high efficacy, low operative morbidity and no systemic side effects. Uterine fibroid treatment using HIFU was effective and safe in treating symptomatic uterine fibroids. Few studies are available in the literature regarding uterine artery embolization (UAE). HIFU provides an excellent option to treat uterine fibroids

  1. Ultrasound observations of subtle movements: a pilot study comparing foetuses of smoking and nonsmoking mothers.

    Science.gov (United States)

    Reissland, Nadja; Francis, Brian; Kumarendran, Kumar; Mason, James

    2015-06-01

    One way to assess foetal health of smokers is to ask mothers to count perceived movements, an unreliable method hiding differences in prenatal development. The aim of this pilot study was to assess subtle foetal movements in ultrasound scans and establish whether they differ in foetuses of mothers who smoked and nonsmoking mothers. This longitudinal pilot study recruited twenty mothers (16 nonsmoking; 4 smoking) scanned four times from 24 to 36 weeks gestation (80 ultrasound scans). Two types of fine-grained movements were coded offline and analysed using a Poisson log-linear mixed model. Foetuses of smoking mothers showed a significantly higher rate of mouth movements compared to foetuses of nonsmoking mothers (p = 0.02), after controlling for maternal stress and depression. As pregnancy progressed, these differences between the smoking and nonsmoking groups widened. Differences between the two groups in the rate of foetal facial self-touch remained constant as pregnancy progressed and were borderline significant (p = 0.07). Rates of foetal mouth movement and facial self-touch differ significantly between smokers and nonsmokers. A larger study is needed to confirm these results and to investigate specific effects, including the interaction of maternal stress and smoking. Additionally, the feasibility of this technique for clinical practice should be assessed. ©2015 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.

  2. THROMBOPHILIA AND INTENSITY OF THE INTRAVASCULAR MICROCOAGULATION IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE, ATHEROTHROMBOSIS

    Directory of Open Access Journals (Sweden)

    E. A. Shelest

    2015-09-01

    Full Text Available Aim. To study the intensity of the intravascular microcoagulation in patients with atherothrombosis (AT, chronic obstructive pulmonary disease (COPD and thrombophilia.Material and methods. 115 patients were enrolled into the study: 37 patients with COPD (22 with thrombophilia and 15 without thrombophilia; 37 patients with AT (23 with thrombophilia and 14 without thrombophilia; 41 patients with COPD+AT (24 with thrombophilia and 17 without thrombophilia. In the control group 53 healthy people (39 with thrombophilia and 14 without thrombophilia were included. Median age was 62 (56.5, 69 years. The intensity of intravascular microcoagulation was measured: platelet factor 4 (PF4 by ELISA, D-dimer by ELISA, XIIa-dependent fibrinolysis (time. Polymerase chain reaction was used for detection of such trombophilia parameters as Leiden mutation, prothrombin gene mutation 20210A, mutation in the gene of methylenetetrahydrofolate reductase (MTHFR and plasminogen activator inhibitor-1 (PAI-1.Results. The level of PF4 and D-dimer was significantly higher while fibrinolytic activity was lower in COPD (103.5 ME/ml, 70 ng/ml, 650 s, respectively, AT (127.1 ME/ml, 96,9 ng/ml, 850 s, respectively and COPD+AT (136.5 ME/ml, 106.5 ng/ml, 1148 s, respectively groups as compared with the control group (p<0.05. When analyzing the level of intravascular coagulation parameters in patients with thrombophilia and without it, levels of PF4, D-dimer and XIIa-dependent fibrinolysis (time were significantly higher in thrombophilia subgroups among all patients (p<0.05. In patients with thrombophilia levels of these parameters were significantly higher in those with two or more thrombophilia gene polymorphisms than with one (p<0.01.Conclusion. The intensity of intravascular microcoagulation increases in patients with thrombophilia, atherothrombosis and COPD.

  3. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  4. Ultrasound parametric imaging of hepatic steatosis using the homodyned-K distribution: An animal study.

    Science.gov (United States)

    Fang, Jui; Zhou, Zhuhuang; Chang, Ning-Fang; Wan, Yung-Liang; Tsui, Po-Hsiang

    2018-02-15

    Hepatic steatosis is an abnormal state where excess lipid mass is accumulated in hepatocyte vesicles. Backscattered ultrasound signals received from the liver contain useful information regarding the degree of steatosis in the liver. The homodyned-K (HK) distribution has been demonstrated as a general model for ultrasound backscattering. The estimator based on the first three integer moments (denoted as "FTM") of the intensity has potential for practical applications because of its simplicity and low computational complexity. This study explored the diagnostic performance of HK parametric imaging based on the FTM method in the assessment of hepatic steatosis. Phantom experiments were initially conducted using the sliding window technique to determine an appropriate window size length (WSL) for HK parametric imaging. Subsequently, hepatic steatosis was induced in male Wistar rats fed a methionine- and choline-deficient (MCD) diet for 0 (i.e., normal control), 1, 2, 4, 6, and 8 weeks (n = 36; six rats in each group). After completing the scheduled MCD diet, ultrasound B-mode and HK imaging of the rat livers were performed in vivo and histopathological examinations were conducted to score the degree of hepatic steatosis. HK parameters μ (related to scatterer number density) and k (related to scatterer periodicity) were expressed as functions of the steatosis stage in terms of the median and interquartile range (IQR). Receiver operating characteristic (ROC) curve analysis was conducted to assess the diagnostic performance levels of the μ and k parameters. The results showed that an appropriate WSL for HK parametric imaging is seven times the pulse length of the transducer. The median value of the μ parameter increased monotonically from 0.194 (IQR: 0.18-0.23) to 0.893 (IQR: 0.64-1.04) as the steatosis stage increased. Concurrently, the median value of the k parameter increased from 0.279 (IQR: 0.26-0.31) to 0.5 (IQR: 0.41-0.54) in the early stages (normal to

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  8. Can Limited Education of Lung Ultrasound Be Conducted to Medical Students Properly? A Pilot Study

    Directory of Open Access Journals (Sweden)

    Jang Sun Lim

    2017-01-01

    Full Text Available Objectives. Lung ultrasonography (LUS is a useful examination to identify lung problems. Unfortunately, there are currently no LUS educational programs for medical students. We designed a brief LUS training course for medical students during the ED rotation. The purpose of training was improving cognitive and psychomotor learning domains, knowledge of ultrasound, knowledge of LUS, image acquisition, and image interpretation. Methods. Forty students in their fourth year of medical school were enrolled in this study. Student achievement was evaluated through examinations of cognitive and psychomotor skills. A survey was administered following the training. Results. The average test result was 42.1 ± 13.7 before training and 82.6 ± 10.7 after training. With respect to the assessment of LUS performance, the acceptable rates for right and left anterior chest wall scanning and right and left posterolateral scanning were 95%, 97.5%, 92.5%, and 100%, respectively. The students felt a high level of confidence in their ability to administer LUS to patients after training and they agreed that inclusion of LUS training in the medical school curriculum is necessary. Conclusion. This study showed that, among the medical students without ultrasound experience, limited LUS education to improve their knowledge, image acquisition, and interpretation ability was successful.

  9. Can Limited Education of Lung Ultrasound Be Conducted to Medical Students Properly? A Pilot Study

    Science.gov (United States)

    Oh, Kyu Ho

    2017-01-01

    Objectives. Lung ultrasonography (LUS) is a useful examination to identify lung problems. Unfortunately, there are currently no LUS educational programs for medical students. We designed a brief LUS training course for medical students during the ED rotation. The purpose of training was improving cognitive and psychomotor learning domains, knowledge of ultrasound, knowledge of LUS, image acquisition, and image interpretation. Methods. Forty students in their fourth year of medical school were enrolled in this study. Student achievement was evaluated through examinations of cognitive and psychomotor skills. A survey was administered following the training. Results. The average test result was 42.1 ± 13.7 before training and 82.6 ± 10.7 after training. With respect to the assessment of LUS performance, the acceptable rates for right and left anterior chest wall scanning and right and left posterolateral scanning were 95%, 97.5%, 92.5%, and 100%, respectively. The students felt a high level of confidence in their ability to administer LUS to patients after training and they agreed that inclusion of LUS training in the medical school curriculum is necessary. Conclusion. This study showed that, among the medical students without ultrasound experience, limited LUS education to improve their knowledge, image acquisition, and interpretation ability was successful. PMID:28459070

  10. Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chih-Chung, E-mail: cchuang@mail.ncku.edu.tw [Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (China); Chen, Wei-Tsen [Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan (China)

    2014-01-15

    Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals.

  11. Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

    International Nuclear Information System (INIS)

    Huang, Chih-Chung; Chen, Wei-Tsen

    2014-01-01

    Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals

  12. Basic study for ultrasound-based navigation for pedicle screw insertion using transmission and backscattered methods.

    Directory of Open Access Journals (Sweden)

    Ziqiang Chen

    Full Text Available The purpose of this study was to understand the acoustic properties of human vertebral cancellous bone and to study the feasibility of ultrasound-based navigation for posterior pedicle screw fixation in spinal fusion surgery. Fourteen human vertebral specimens were disarticulated from seven un-embalmed cadavers (four males, three females, 73.14 ± 9.87 years, two specimens from each cadaver. Seven specimens were used to measure the transmission, including tests of attenuation and phase velocity, while the other seven specimens were used for backscattered measurements to inspect the depth of penetration and A-Mode signals. Five pairs of unfocused broadband ultrasonic transducers were used for the detection, with center frequencies of 0.5 MHz, 1 MHz, 1.5 MHz, 2.25 MHz, and 3.5 MHz. As a result, good and stable results were documented. With increased frequency, the attenuation increased (P0.05. At about 0.6 cm away from the cortical bone, warning signals were easily observed from the backscattered measurements. In conclusion, the ultrasonic system proved to be an effective, moveable, and real-time imaging navigation system. However, how ultrasonic navigation will benefit pedicle screw insertion in spinal surgery needs to be determined. Therefore, ultrasound-guided pedicle screw implantation is theoretically effective and promising.

  13. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    International Nuclear Information System (INIS)

    Koo, Kevin S.H.; Dowd, Christopher F.; Hess, Christopher P.; Mathes, Erin F.; Frieden, Ilona J.; Rosbe, Kristina W.; Hoffman, William Y.

    2015-01-01

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  14. MRI phenotypes of localized intravascular coagulopathy in venous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kevin S.H. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dowd, Christopher F.; Hess, Christopher P. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Mathes, Erin F.; Frieden, Ilona J. [University of California, San Francisco, Department of Dermatology, San Francisco, CA (United States); Rosbe, Kristina W. [University of California, San Francisco, Department of Otolaryngology, San Francisco, CA (United States); Hoffman, William Y. [University of California, San Francisco, Department of Surgery, San Francisco, CA (United States)

    2015-10-15

    The incidence of localized intravascular coagulopathy (LIC) in venous malformations varies with lesion size and location, as well as the presence of palpable phleboliths. The development of LIC can cause pain and hemorrhage and can progress to disseminated intravascular coagulopathy (DIC) and thromboembolic disease resulting in death in some cases. Early recognition of LIC can relieve symptoms and prevent progression to life-threatening complications. The aim of this work was to identify MRI features of venous malformation associated with LIC. We hypothesized that venous malformations with larger capacitance, slower flow and less physiological compression (greater stasis) were more likely to be associated with LIC. In this HIPAA-compliant and IRB-approved study, we retrospectively reviewed clinical records and MRI for consecutive patients undergoing evaluation of venous malformations at our multidisciplinary Birthmarks and Vascular Anomalies Center between 2003 and 2013. Inclusion required consensus diagnosis of venous malformation and availability of laboratory data and MRI; patients on anticoagulation or those previously undergoing surgical or endovascular treatment were excluded. LIC was diagnosed when D-dimer exceeded 1,000 ng/mL and/or fibrinogen was less than 200 mg/dL. Two board-certified radiologists assessed the following MRI features for each lesion: morphology (spongiform vs. phlebectatic), presence of phleboliths, size, location (truncal vs. extremity), and tissue type(s) involved (subcutis, muscle, bone and viscera). Univariate logistic regression analyses were used to test associations between LIC and MRI findings, and stepwise regression was applied to assess the significance of the individual imaging predictors. Seventy patients, 37 with LIC, met inclusion criteria during the 10-year study period (age: 14.5 +/- 13.6 years [mean +/- standard deviation]; 30 male, 40 female). Both elevated D-dimer and low fibrinogen were associated with the presence of

  15. Disseminated intravascular coagulation caused by moojenactivase, a procoagulant snake venom metalloprotease.

    Science.gov (United States)

    Sartim, Marco A; Cezarette, Gabriel N; Jacob-Ferreira, Anna L; Frantz, Fabiani G; Faccioli, Lucia H; Sampaio, Suely V

    2017-10-01

    Snake venom toxins that activate coagulation factors are key players in the process of venom-induced coagulopathy, and account for severe clinical manifestations. The present study applies a variety of biochemical, hematological, and histopathological approaches to broadly investigate the intravascular and systemic effects of moojenactivase (MooA), the first described PIIId subclass metalloprotease isolated from Bothrops sp. venom that activates coagulation factors. MooA induced consumption coagulopathy with high toxic potency, characterized by prolongation of prothrombin and activated partial thromboplastin time, consumption of fibrinogen and the plasma coagulation factors X and II, and thrombocytopenia. MooA promoted leukocytosis and expression of the proinflammatory cytokines interleukin-6 and tumor necrosis factor-α, accompanied by tissue factor-dependent procoagulant activity in peripheral blood mononuclear cells. This metalloprotease also caused intravascular hemolysis, elevated plasma levels of creatine kinase-MB, aspartate transaminase, and urea/creatinine, and induced morphopathological alterations in erythrocytes, heart, kidney, and lungs associated with thrombosis and hemorrhage. Diagnosis of MooA-induced disseminated intravascular coagulation represents an important approach to better understand the pathophysiology of Bothrops envenomation and develop novel therapeutic strategies targeting hemostatic disturbances. Copyright © 2017. Published by Elsevier B.V.

  16. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  17. Refugee and Migrant Women's Views of Antenatal Ultrasound on the Thai Burmese Border: A Mixed Methods Study

    Science.gov (United States)

    Thwin, May Myo; Ladda Kajeechewa, Honey Moon; Wiladphaingern, Jacher; Lwin, Khin Maung; Jones, Caroline; Nosten, François; McGready, Rose

    2012-01-01

    Background Antenatal ultrasound suits developing countries by virtue of its versatility, relatively low cost and safety, but little is known about women’s or local provider’s perspectives of this upcoming technology in such settings. This study was undertaken to better understand how routine obstetric ultrasound is experienced in a displaced Burmese population and identify barriers to its acceptance by local patients and providers. Methodology/Principal Findings Qualitative (30 observations, 19 interviews, seven focus group discussions) and quantitative methods (questionnaire survey with 644 pregnant women) were used to provide a comprehensive understanding along four major themes: safety, emotions, information and communication, and unintended consequences of antenatal ultrasound in refugee and migrant clinics on the Thai Burmese border. One of the main concerns expressed by women was the danger of childbirth which they mainly attributed to fetal malposition. Both providers and patients recognized ultrasound as a technology improving the safety of pregnancy and delivery. A minority of patients experienced transitory shyness or anxiety before the ultrasound, but reported that these feelings could be ameliorated with improved patient information and staff communication. Unintended consequences of overuse and gender selective abortions in this population were not common. Conclusions/Significance The results of this study are being used to improve local practice and allow development of explanatory materials for this population with low literacy. We strongly encourage facilities introducing new technology in resource poor settings to assess acceptability through similar inquiry. PMID:22514615

  18. Fulminant intravascular lymphomatosis mimicking acute haemorrhagic leukoencephalopathy.

    Science.gov (United States)

    Marino, D; Sicurelli, F; Cerase, A; Tripodi, S; Cintorino, M; Lazzi, S; Federico, A

    2012-09-15

    Intravascular lymphomatosis (IVL) is a rare non-Hodgkin's lymphoma, usually of B cell lineage, characterized by massive angiotropic growth. The clinical presentation of IVL may include changes in mental status, non-localizing neurological deficits, seizures, fever of unknown origin and skin changes. Because of its rarity and the absence of specific diagnostic procedures except for cerebral biopsy, diagnosis is often postmortem. Brain MRI usually shows non-specific abnormalities. The purpose of this case report is to increase the knowledge of clinical and neuroimaging features of IVL by describing the findings observed in a 71-year-old patient. A 71-year-old male was admitted for right hemiparesis, acute cognitive impairment and febricula. A bone marrow biopsy resulted normal. He then developed a rapid progressive impairment of his mental status and left hemisoma motor seizures. Brain CT and MRI were interpreted as consistent with acute haemorrhagic leukoencephalopathy (AHLE), including multiple areas of restricted diffusion without gadolinium enhancement and a small focal area of gadolinium enhancement in the left temporal lobe white matter. The patient died within a few days and the autopsy led to the diagnosis of IVL. IVL may present with a variety of clinical signs and symptoms, including stroke and hemiparesis. IVL may mimic AHLE at brain MRI. However, the evidence of multiple areas of restricted diffusion without gadolinium enhancement and of a small area of gadolinium enhancement could have led to the correct diagnosis. IVL should be added to the differential diagnosis of AHLE at brain MRI. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. [Study on therapeutic dosimetry and biologic effect of high intensity focused ultrasound].

    Science.gov (United States)

    He, Xuemei; Xiong, Xin; Zou, Jianzhong; Li, Faqi; Ma, Ping; Wang, Zhibiao

    2009-02-01

    This study was aimed at exploring the high intensity focused ultrasound(HIFU) therapeutic dosimetry and its biologic effect. In-vitro, bovine liver was immersed into 0.9% NS and degassed for application. The JC Model-focused ultrasound tumor therapeutic system was used in the experiment. The HIFU parameters were: frequency 1.6 MHz, depth 20 mm, acoustic power from 16.44 W to 196.32 W. Under each power, at radiating times from is to 20 s, bioptic specimens were obtained from all samples. The results showed when the acoustic power was equal to or higher than 179.96 W, only is of radiating is adequate to induce coagulative necrosis, and when the acoustic power was lower than 65.44 W, the radiating time to produce coagulative necrosis was about 7 s. In the range of 65.44-179.96 W, at each time when the acoustic power was set up with an increment of 16.36 W, the time to produce coagulative necrosis was 1-2 s shorter. The form of biological focal region (BFR) varied with the acoustic power and HIFU irradiation time. The size of BFR increased with the increase of HIFU irradiation dosage (acoustic power x exposure time). There is positive correlation between the size of BFR and the dosage of HIFU irradiation (y = 0.0164x(1.05591), R5 = 0.9238, P < 0.05).

  20. Ultrasound-guided regional anesthesia for pediatric burn reconstructive surgery; a prospective study

    Science.gov (United States)

    Shank, Erik S.; Martyn, Jeevendra A.; Donelan, Mathias B.; Perrone, Anthony; Firth, Paul G.; Driscoll, Daniel N.

    2014-01-01

    Pediatric patients face multiple reconstructive surgeries to re-establish function and aesthetics post burn injury. Often, the site of the harvested graft for these reconstructions is reported to be the most painful part of the procedure and a common reason for deferring these reconstructive procedures. This study in pediatric burn patients undergoing reconstructive procedures examined the analgesia response to local anesthetic infiltration versus either a single ultrasound guided regional nerve block of the lateral femoral cutaneous nerve, or a fascia-iliaca compartment block with catheter placement and continuous infusion. Methods 19 patients were randomized to one of three groups (infiltration, single shot nerve block, or compartment block with catheter) and received intraoperative analgesia intervention. Post-operatively, visual analog scale pain scores were recorded –for pain at the donor site—every four hours while awake—for forty-eight hours. Results This non-parametric data was analyzed using a two way ANOVA, Friedman's test, and Kruskal-Walllis test, with significance determined at panesthetic block of the lateral femoral cutaneous nerve, with or without catheter placement, provides an improved postoperative experience for the pediatric patient undergoing reconstructive surgery with lateral/anterolateral skin graft versus local anesthesia infiltration of donor site. For optimal comfort throughout the postoperative period, an ultrasound guided block with continuous catheter may be beneficial. PMID:25412051

  1. Ultrasound determination of gestational age using placental thickness in female dogs: an experimental study.

    Science.gov (United States)

    Maldonado, André Luiz Louzada; Araujo Júnior, Edward; Mendonça, Débora Sartori; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes; Ajzen, Sérgio Aron

    2012-01-01

    Objective. To verify if the placental thickness allows determining the gestational age, evaluating the correlation between the referred gestational age with the studied one, and the accuracy of the placental thickness measurement (biometry) with fetal morphologic parameters in bitches. Methods. The placental thickness of 336 bitches of diverse breeds was evaluated. Bitches were divided in three groups by body weight: small, medium, and big large size. The gestations pregnancies were evaluated by ultrasound from the third week of gestation. An analysis was performed between the mean values of the gestational age obtained of placental thickness by adjustment of curves and the reported gestational age. Student's t-test was applied to compare the mean of reported and placental thickness gestational age. Significance was defined as P < 0.05. Results. A positive and statistically significant correlation exists between the placental thickness and gestational age. The expression that presents the best correlation coefficient and explanation was thickness of placenta = 0.021x gestational age -0.314. Conclusion. It is possible to determine the gestational age in relation to the placental thickness measured by ultrasound in bitches with a satisfactory accuracy in relation to fetal morphologic parameters as gestational vesicle, ribs, or kidneys.

  2. Use of ultrasound imaging by physiotherapists: a pilot study to survey use, skills and training.

    Science.gov (United States)

    Potter, Catherine L; Cairns, Mindy C; Stokes, Maria

    2012-02-01

    This study aimed to design and pilot a questionnaire to survey the use of ultrasound imaging (USI) by physiotherapists in the United Kingdom (UK), the type and content of ultrasound training physiotherapists using USI had undertaken and their perceived future training needs. The use of USI by physiotherapists is becoming increasingly common but is highly operator dependent and there are safety and professional issues regarding use in physiotherapy practice. Currently there are no specific training guidelines relating to physiotherapists using USI. A questionnaire was developed, based on research literature and guidelines. Twelve experts in USI commented on the content and design. The electronic on-line questionnaire was piloted on groups that were likely to be users of USI. Forty-six respondents completed the questionnaire. Results indicated that USI is used predominantly for biofeedback and there are many unmet training needs. Respondents reported a mismatch between techniques for which they had received training and those that they used in practice and indicated a more structured training framework is required. The development and piloting of the questionnaire provides a starting point for a more extensive evaluation of how USI is being used, the training needs of physiotherapists and benefits as a biofeedback tool. Refinement is needed and replication in a larger sample. Results could assist the development of a structured formal training framework encompassing key skills. Copyright © 2011. Published by Elsevier Ltd.

  3. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    Energy Technology Data Exchange (ETDEWEB)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com [Imagerie Médicale Paris Centre Bachaumont-clinique Blomet RamsayGDS, Department of Interventional Radiology (France); Baere, Thierry De, E-mail: Debaere@igr.fr [Gustave Roussy Institute (France); Vigan, Marie, E-mail: marie.vigan@gmail.com [Association pour la recherche en chirurgie de l’épaule et du coude, clinique Drouot (France); Hakimé, Antoine, E-mail: thakime@yahoo.com [Imagerie Médicale Paris Centre Bachaumont-clinique Blomet RamsayGDS, Department of Interventional Radiology (France)

    2017-04-15

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 at baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.

  4. The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study

    International Nuclear Information System (INIS)

    Pajek, Daniel; Hynynen, Kullervo

    2012-01-01

    High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1–1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum –3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke. (paper)

  5. Ultrasound guided injection of a painful knee osteoarthritis with medial meniscus extrusion: a case series study.

    Science.gov (United States)

    Di Sante, Luca; Venditto, Teresa; Ioppolo, Francesco; Paoloni, Marco; Mangone, Massimiliano; Alviti, Federica

    2017-01-01

    Meniscal subluxation results in the natural history of knee osteoarthritis (OA). Periarticular infiltration should minimize possible complications related to penetration of corticosteroids into the joint space in the treatment of knee OA.According to pain relief and improvement of function, the aim of this study is to evaluate the effectiveness of perimeniscal corticosteroid ultrasound guided injection in knee OA. Thirty-two patients received an injection of 0.5 ml of methylprednisolone-acetate around perimeniscal tissues. Outcome measures were pain relief and knee function, assessed by Visual Analogue Scale (VAS) [24, 29, 30] measured at rest (VAS-R) and during stairs climbing (VAS-C) and by Italian-Western Ontario and McMaster Universities (WOMAC) scale. Clinical evaluation was performed at baseline, at 1 and 4 weeks of follow-up. Mean baseline values of VAS-R and VAS-C were 6.79 ± 1.17 and 7.6 ± 1.39, respectively. All subjects showed a significant reduction in pain over time (p 0.05). Corticosteroid perimeniscal ultrasound guided injection can be considered as an adjunct to core treatment for the relief of moderate to severe pain in people with knee OA. IV.

  6. Ultrasound Determination of Gestational Age Using Placental Thickness in Female Dogs: An Experimental Study

    Directory of Open Access Journals (Sweden)

    André Luiz Louzada Maldonado

    2012-01-01

    Full Text Available Objective. To verify if the placental thickness allows determining the gestational age, evaluating the correlation between the referred gestational age with the studied one, and the accuracy of the placental thickness measurement (biometry with fetal morphologic parameters in bitches. Methods. The placental thickness of 336 bitches of diverse breeds was evaluated. Bitches were divided in three groups by body weight: small, medium, and big large size. The gestations pregnancies were evaluated by ultrasound from the third week of gestation. An analysis was performed between the mean values of the gestational age obtained of placental thickness by adjustment of curves and the reported gestational age. Student's t-test was applied to compare the mean of reported and placental thickness gestational age. Significance was defined as P<0.05. Results. A positive and statistically significant correlation exists between the placental thickness and gestational age. The expression that presents the best correlation coefficient and explanation was thickness of placenta = 0.021x gestational age −0.314. Conclusion. It is possible to determine the gestational age in relation to the placental thickness measured by ultrasound in bitches with a satisfactory accuracy in relation to fetal morphologic parameters as gestational vesicle, ribs, or kidneys.

  7. Hydrogel based tissue mimicking phantom for in-vitro ultrasound contrast agents studies.

    Science.gov (United States)

    Demitri, Christian; Sannino, Alessandro; Conversano, Francesco; Casciaro, Sergio; Distante, Alessandro; Maffezzoli, Alfonso

    2008-11-01

    Ultrasound medical imaging (UMI) is the most widely used image analysis technique, and often requires advanced in-vitro set up to perform morphological and functional investigations. These studies are based on contrast properties both related to tissue structure and injectable contrast agents (CA). In this work, we present a three-dimensional structure composed of two different hydrogels reassembly the microvascular network of a human tissue. This phantom was particularly suitable for the echocontrastographic measurements in human microvascular system. This phantom has been characterized to present the acoustic properties of an animal liver, that is, acoustic impedance (Z) and attenuation coefficient (AC), in UMI signal analysis in particular; the two different hydrogels have been selected to simulate the target organ and the acoustic properties of the vascular system. The two hydrogels were prepared starting from cellulose derivatives to simulating the target organ parenchyma and using a PEG-diacrylate to reproduce the vascular system. Moreover, harmonic analysis was performed on the hydrogel mimicking the liver parenchyma hydrogel to evaluate the ultrasound (US) distortion during echographic measurement. The phantom was employed in the characterization of an experimental US CA. Perfect agreement was found when comparing the hydrogel acoustical properties materials with the corresponding living reference tissues (i.e., vascular and parenchimal tissue).

  8. Variations in clinical presentation, frequency of hemophagocytosis and clinical behavior of intravascular lymphoma diagnosed in different geographical regions

    NARCIS (Netherlands)

    Ferreri, Andrés J M; Dognini, Giuseppina P; Campo, Elías; Willemze, Rein; Seymour, John F; Bairey, Osnat; Martelli, Maurizio; De Renz, Amalia O; Doglioni, Claudio; Montalbán, Carlos; Tedeschi, Alberto; Pavlovsky, Astrid; Morgan, Sue; Uziel, Lilj; Ferracci, Massimo; Ascani, Stefano; Gianelli, Umberto; Patriarca, Carlo; Facchetti, Fabio; Dalla Libera, Alessio; Pertoldi, Barbara; Horváth, Barbara; Szomor, Arpad; Zucca, Emanuele; Cavalli, Franco; Ponzoni, Maurilio

    BACKGROUND AND OBJECTIVES: This study explored variations in the clinical manifestations of intravascular lymphoma (IVL) on the bases of the association with hemophagocytosis and the country where the diagnosis was made. DESIGN AND METHODS: The clinical features of 50 Western patients with IVL were

  9. The Clinical Atlas of Intravascular Optical Coherence Tomography for iPad

    DEFF Research Database (Denmark)

    Radu, Maria D

    2012-01-01

    The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing.......The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing....

  10. Low molecular weight heparin attenuates multiple organ failure in a murine model of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Slofstra, Sjoukje H.; van 't Veer, Cornelis; Buurman, Wim A.; Reitsma, Pieter H.; ten Cate, Hugo; Spek, C. Arnold

    2005-01-01

    OBJECTIVE: Bacterial sepsis causes widespread vascular inflammation that frequently leads to disseminated intravascular coagulation (DIC). Although intravascular coagulation contributes to organ failure, it is often debated whether anticoagulant therapy produces any beneficial effects in patients

  11. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  12. Performance study of a new time-delay estimation algorithm in ultrasonic echo signals and ultrasound elastography.

    Science.gov (United States)

    Shaswary, Elyas; Xu, Yuan; Tavakkoli, Jahan

    2016-07-01

    Time-delay estimation has countless applications in ultrasound medical imaging. Previously, we proposed a new time-delay estimation algorithm, which was based on the summation of the sign function to compute the time-delay estimate (Shaswary et al., 2015). We reported that the proposed algorithm performs similar to normalized cross-correlation (NCC) and sum squared differences (SSD) algorithms, even though it was significantly more computationally efficient. In this paper, we study the performance of the proposed algorithm using statistical analysis and image quality analysis in ultrasound elastography imaging. Field II simulation software was used for generation of ultrasound radio frequency (RF) echo signals for statistical analysis, and a clinical ultrasound scanner (Sonix® RP scanner, Ultrasonix Medical Corp., Richmond, BC, Canada) was used to scan a commercial ultrasound elastography tissue-mimicking phantom for image quality analysis. The statistical analysis results confirmed that, in overall, the proposed algorithm has similar performance compared to NCC and SSD algorithms. The image quality analysis results indicated that the proposed algorithm produces strain images with marginally higher signal-to-noise and contrast-to-noise ratios compared to NCC and SSD algorithms. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  14. A qualitative study of women's decision to view or not view an ultrasound image before early medication abortion.

    Science.gov (United States)

    Cappiello, Joyce; Merrell, Joy; Rentschler, Dorothy

    2014-01-01

    Transvaginal ultrasounds are commonly performed for gestational dating of pregnancy before a medication abortion. This paper presents findings regarding women's perspectives on viewing the gestational dating ultrasound image, which arose from a study exploring women's medication abortion experience. By providing women the opportunity to talk about their medication abortion experience through open-ended interviews, women reported their experience of viewing or not viewing the ultrasound in detail, which to date has been underexplored. A constructivist, grounded theory approach was used. The purposive sample consisted of 18 women in the United States who experienced a medication abortion in the preceding 4 months. Not all women wanted to view the ultrasound; however, they all wanted a choice. Women wanted to view the image to confirm health and fertility, satisfy curiosity, and process their decision regarding the pregnancy. None of the women stated that they wanted to view the image as a prerequisite to making their decision to terminate the pregnancy; rather, viewing was a way to process their decision. Women wanted a choice of whether to view the ultrasound image because they felt it was their right to decide whether to access this aspect of their personal health information. They wanted providers to engage in a dialogue about viewing the image or not and to respect their decision. Providers need to be appropriately prepared to offer women the choice to view and to support women in their decision. Copyright © 2014 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  15. Focused ultrasound subthalamotomy in patients with asymmetric Parkinson's disease: a pilot study.

    Science.gov (United States)

    Martínez-Fernández, Raul; Rodríguez-Rojas, Rafael; Del Álamo, Marta; Hernández-Fernández, Frida; Pineda-Pardo, Jose A; Dileone, Michele; Alonso-Frech, Fernando; Foffani, Guglielmo; Obeso, Ignacio; Gasca-Salas, Carmen; de Luis-Pastor, Esther; Vela, Lydia; Obeso, José A

    2018-01-01

    Ablative neurosurgery has been used to treat Parkinson's disease for many decades. MRI-guided focused ultrasound allows focal lesions to be made in deep brain structures without skull incision. We investigated the safety and preliminary efficacy of unilateral subthalamotomy by focused ultrasound in Parkinson's disease. This prospective, open-label pilot study was done at CINAC (Centro Integral de Neurociencias), University Hospital HM Puerta del Sur in Madrid, Spain. Eligible participants had Parkinson's disease with markedly asymmetric parkinsonism. Patients with severe dyskinesia, history of stereotactic surgery or brain haemorrhage, a diagnosis of an unstable cardiac or psychiatric disease, or a skull density ratio of 0·3 or less were excluded. Enrolled patients underwent focused ultrasound unilateral subthalamotomy. The subthalamic nucleus was targeted by means of brain images acquired with a 3-Tesla MRI apparatus. Several sonications above the definitive ablation temperature of 55°C were delivered and adjusted according to clinical response. The primary outcomes were safety and a change in the motor status of the treated hemibody as assessed with part III of the Movement Disorders Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS III) in both off-medication and on-medication states at 6 months. Adverse events were monitored up to 48 h after treatment and at scheduled clinic visits at 1, 3, and 6 months after treatment. The study is registered with ClinicalTrials.gov, number NCT02912871. Between April 26 and June 14, 2016, ten patients with markedly asymmetric parkinsonism that was poorly controlled pharmacologically were enrolled for focused ultrasound unilateral subthalamotomy. By 6 months follow-up, 38 incidents of adverse events had been recorded, none of which were serious or severe. Seven adverse events were present at 6 months. Three of these adverse events were directly related to subthalamotomy: off-medication dyskinesia in the treated arm

  16. Ultrasound-guided brachial plexus block: a study on 30 patients

    Directory of Open Access Journals (Sweden)

    Amiri HR

    2009-05-01

    Full Text Available "n Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Successful brachial plexus blocks rely on proper techniques of nerve localization, needle placement, and local anesthetic injection. Standard approaches used today (elicitation of paresthesia or nerve-stimulated muscle contraction, unfortunately, are all "blind" techniques resulting in procedure-related pain and complications. Ultrasound guidance for brachial plexus blocks can potentially improve success and complication rates. This study presents the ultrasound-guided brachial plexus blocks for the first time in Iran in adults and pediatrics. "n"n Methods: In this study ultrasound-guided brachial plexus blocks in 30 patients (25 adults & 5 pediatrics scheduled for an elective upper extremity surgery, are introduced. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. Besides basic variables, block approach, block time, postoperative analgesia duration (VAS<3 was considered as target pain control opioid consumption during surgery, patient satisfaction and block related complications were reported

  17. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  18. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  19. Rating scale for the assessment of competence in ultrasound-guided peripheral vascular access - a Delphi Consensus Study

    DEFF Research Database (Denmark)

    Primdahl, Stine C; Todsen, Tobias; Clemmesen, Marie Louise

    2016-01-01

    INTRODUCTION: Peripheral vascular access is vital for treatment and diagnostics of hospitalized patients. Ultrasound-guided vascular access (UGVA) is superior to the landmark technique. To ensure competence-based education, an assessment tool of UGVA competence is needed. We aimed to develop...... a global rating scale (RS) for assessment of UGVA competence based on opinions on the content from ultrasound experts in a modified Delphi consensus study. METHODS: We included experts from anesthesiology, emergency medicine and radiology across university hospitals in Denmark. Nine elements were drafted...... Delphi round, the experts excluded one element from the scale. In the third Delphi round, consensus was obtained on the eight elements: preparation of utensils, ergonomics, preparation of the ultrasound device, identification of blood vessels, anatomy, hygiene, coordination of the needle, and completion...

  20. The application of transabdominal 3D ultrasound for the diagnosis of gastric varices: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Hitoshi, E-mail: maru-cib@umin.ac.jp; Kamezaki, Hidehiro, E-mail: ugn29814@yahoo.co.jp; Kondo, Takayuki, E-mail: takakondonaika@yahoo.co.jp; Sekimoto, Tadashi, E-mail: tad_sekimoto@yahoo.co.jp; Shimada, Taro, E-mail: bobtaro51@yahoo.co.jp; Takahashi, Masanori, E-mail: machat1215@yahoo.co.jp; Yokosuka, Osamu, E-mail: yokosukao@faculty.chiba-u.jp

    2013-09-15

    Objective: The aim of this study was to determine the feasibility of using transabdominal three-dimensional (3D) colour Doppler ultrasound as a non-invasive tool to demonstrate and quantify gastric varices. Subjects and methods: A phantom study compared the 3D water flow volume data in a hose with the actual volume inside the hose at three different flow velocities. The prospective clinical study examined the reliability and reproducibility of 3D volume data for gastric varices (mild 28, moderate 26, large 8) in 62 patients. The 3D images were acquired using the colour Doppler with both convex and micro-convex probes. Results: The phantom study showed a 12.4–17.6% difference between the 3D data and the actual volume with no difference between the two types of probes or three velocities. The detectability of gastric varices was identical between the two probes (54/62, 87.1%). However, the scanning efficiency was significantly greater for the micro-convex probe (66.9 ± 14.1%) than the convex probe (57.3 ± 14%, p = 0.012). Body mass index was the only factor that had a significant relationship with the detectability of varices. The mean volume (mL) of the 3D signal was 0.82 ± 0.74 for mild varices, 5.48 ± 3.84 for moderate varices, and 10.63 ± 6.67 for large varices with significant differences between different grades. The intra-/inter-rater reliability was excellent. Conclusion: The method of 3D colour Doppler ultrasound is reliable and reproducible in the quantitative assessment of vascular volume and is applicable for grading gastric varices. This study may offer a practical usefulness for 3D ultrasonography as an alternative to endoscopy.

  1. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-07-01

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  2. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular... and Personal Use Therapeutic Devices § 880.5970 Percutaneous, implanted, long-term intravascular catheter. (a) Identification. A percutaneous, implanted, long-term intravascular catheter is a device that...

  3. 21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subcutaneous, implanted, intravascular infusion... Hospital and Personal Use Therapeutic Devices § 880.5965 Subcutaneous, implanted, intravascular infusion port and catheter. (a) Identification. A subcutaneous, implanted, intravascular infusion port and...

  4. Ultrasound Assessment of Umbilical Cord Morphology in the First Trimester: A Feasibility Study

    DEFF Research Database (Denmark)

    Narayan, Rajit; Saaid, Rahmah; Pedersen, Lars Henning

    2015-01-01

    Objective: The aim of this study was to determine whether morphology and measurement of the umbilical cord could be accurately assessed at the time of the 11- to 13+6-week scan. Methods: We conducted a prospective study of 100 consecutive women with singleton pregnancies at 11-13+6 weeks' gestation...... who were seen for routine aneuploidy screening. Transabdominal ultrasound scans were performed, and the distance between two adjacent coils of the umbilical artery was measured in a free loop of umbilical cord. The antenatal umbilical coiling index (aUCI) was calculated as the inverse...... velocity also increased with gestation. Interobserver consistency in the objective measurement of the aUCI was poor (kappa 0.146). However, the Sepulveda classification system was found to be applicable and reproducible at this period of gestation (kappa 0.601). Conclusions: Umbilical cord morphology can...

  5. Effectiveness of using ultrasound therapy and manual therapy in the conservative treatment of calcaneal spur – pilot study

    Directory of Open Access Journals (Sweden)

    Twarowska Natalia

    2016-06-01

    Full Text Available Introduction: Calcaneal spur is a pathology of the fibrocartilage enthesis of the Achilles tendon and plantar fascia or a pathology of the mixed enthesis of the flexor digitorum brevis muscle. Ultrasound therapy is commonly applied in the conservative treatment of a calcaneal spur. Foot muscle strengthening exercises, stretching exercises and soft tissue therapy are indicated as effective methods of conservative treatment. The aim of the study was to compare and assess the effects of ultrasound therapy and selected techniques of manual therapy on pain level and functional state in patients with calcaneal spur.

  6. ‘Essential but not always available when needed’ – an interview study of physicians’ experiences and views regarding use of obstetric ultrasound in Tanzania

    Directory of Open Access Journals (Sweden)

    Annika Åhman

    2016-07-01

    Full Text Available Background: The value of obstetric ultrasound in high-income countries has been extensively explored but evidence is still lacking regarding the role of obstetric ultrasound in low-income countries. Objective: We aimed to explore experiences and views among physicians working in obstetric care in Tanzania, on the role of obstetric ultrasound in relation to clinical management. Design: A qualitative study design was applied. Data were collected in 2015, through 16 individual interviews with physicians practicing in obstetric care at hospitals in an urban setting in Tanzania. Data were analyzed using qualitative content analysis. Results: Use of obstetric ultrasound in the management of complicated pregnancy was much appreciated by participating physicians, although they expressed considerable concern about the lack of ultrasound equipment and staff able to conduct the examinations. These limitations were recognized as restricting physicians’ ability to manage complications adequately during pregnancy and birth. Better availability of ultrasound was requested to improve obstetric management. Concerns were also raised regarding pregnant women's lack of knowledge and understanding of medical issues which could make counseling in relation to obstetric ultrasound difficult. Although the physicians perceived a positive attitude toward ultrasound among most pregnant women, occasionally they came across women who feared that ultrasound might harm the fetus. Conclusions: There seems to be a need to provide more physicians in antenatal care in Tanzania with ultrasound training to enable them to conduct obstetric ultrasound examinations and interpret the results themselves. Physicians also need to acquire adequate counseling skills as counseling can be especially challenging in this setting where many expectant parents have low levels of education. Providers of obstetric care and policy makers in Tanzania will need to take measures to ensure appropriate

  7. Ultrasound of the traumatized scrotum

    International Nuclear Information System (INIS)

    Lee, Choon Keun; Park, Yong Tai; Cho, Kyung Sik; Ko, Young Tae; Lee, Dong Ho; Lim, Jae Hoon

    1988-01-01

    A retrospective study was undertaken to assess the importance of ultrasound in the evaluation of scrotal trauma in 25 patients suffered from various types of trauma. Eleven patients were managed surgically and 14 patients were managed conservatively on the basis of ultrasound diagnosis. Ultrasound was valuable in the evaluation of the degree of injury and determination of early therapeutic modality for surgical of conservative manner. Ultrasound is noninvasive, convenient and also valuable in follow up study. Ultrasound is considered the technique is choice in the initial evaluation of scrotal trauma.

  8. Mechanism study of multimode ultrasound pretreatment on the enzymolysis of wheat gluten.

    Science.gov (United States)

    Zhang, Yanyan; Li, Jing; Li, Suyun; Ma, Haile; Zhang, Hua

    2018-03-01

    Ultrasound pretreatment could improve the angiotensin-I converting enzyme (ACE) inhibitory activity of hydrolysates of wheat gluten (WG). The working mode of ultrasound has an important effect on the enzymatic hydrolysis of protein. The results showed that the optimum working mode of ultrasound was alternate dual-frequency mode (20/35 kHz), substrate concentration was 30 g L -1 , initial temperature of the suspension was 30 °C, ultrasound pretreatment time was 10 min and power density was 150 W L -1 . Under optimised conditions, ACE inhibitory activity of WG hydrolysates reached to its maximum value in advance. The surface hydrophobicity (H 0 ) of WG and the content of small peptides at the beginning of the enzymolysis were improved by the ultrasound pretreatment. The structure of WG was destroyed by the ultrasound pretreatment. The enzymatic residue of ultrasound pretreated WG were damaged greater than control. It was concluded that alternate dual-frequency ultrasound pretreatment improved the ACE inhibitory activity. Ultrasonic pretreatment may loosen the tissue of WG aggregate, and help the enzyme alcalase to attack the interior of WG aggregate easily, which resulted in the release of low molecular weight peptides from WG aggregate. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Maxillary length in 11- to 26-week-old normal fetuses studied by 3D ultrasound

    DEFF Research Database (Denmark)

    Hermann, N V; Darvann, T A; Sundberg, K

    2015-01-01

    OBJECTIVES: The objective of this article is to investigate normal prenatal maxillary length using 3D ultrasound and to correlate this with previously reported results for the mandible and the biparietal diameter (BPD). METHODS: Seventy-two 3D ultrasound volumes from normal pregnancies in 52 volu...

  10. Diffraction and coherence in breast ultrasound tomography: a study with a toroidal array

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLL.; Duric, Neb [KCI; Littrup, Peter [KCI

    2008-01-01

    Ultrasound is commonly used as an adjunct to mammography for diagnostic evaluation of suspicions arising from breast cancer screening. As an alternative to conventional sonography that uses hand-held transducers, toroidal array probes that encircle the breast immersed in a water bath have been investigated for ultrasound tomography. In this paper, two sets of experiments performed with a prototype ultrasound scanner on a phantom and a human breast in vivo are used to investigate the effects of diffraction and coherence in ultrasound tomography. Reconstructions obtained with transmission diffraction tomography (TDT) are compared with conventional reflection imaging and computerized ultrasound tomography showing a substantial improvement. The in vivo tests demonstrate that TDT can image the complex boundary of a cancer mass and suggest that it can reveal the anatomy of milk ducts and Cooper's ligaments.

  11. The effects of serial intravascular transfusions in ascitic/hydropic RhD-alloimmunized fetuses.

    Science.gov (United States)

    Craparo, F J; Bonati, F; Gementi, P; Nicolini, U

    2005-02-01

    To evaluate the effects of serial intravascular transfusions on RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion by measuring multiple hematological/biochemical blood variables. Thirty-one singleton pregnancies were referred for management of RhD alloimmunization. Seven fetuses had hydrops on presentation and were transfused immediately. The remainder underwent weekly ultrasound examinations, and fetal blood sampling and transfusion were performed on development of ascites. In the 104 samples collected overall from the 31 fetuses, glucose, uric acid, urea, creatinine, total protein, total and direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase, alkaline phosphatase, lactic dehydrogenase, amylase, pseudocholinesterase (PCHE), creatine kinase, triglycerides and cholesterol were measured and compared with a reference range for non-anemic fetuses. The median gestational age at first transfusion was 26 (range, 18-34) weeks. There were three fetal losses after the first transfusion, two of which were due to procedure-related complications; one further loss occurred. At the first transfusion fetal hematocrit, pO2, total protein, PCHE, creatinine and urea concentrations were significantly decreased compared to reference data, while total and direct bilirubin, AST, ALT, amylase, triglyceride and uric acid concentrations were increased. In all surviving fetuses ascites/hydrops had disappeared by the second transfusion. Fetal pO2, total protein, AST, ALT and PCHE concentrations had normalized by the third transfusion. Correction of fetal anemia did not affect the other variables. RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion had a survival rate of 87%. Alterations of several biochemical fetal blood indices are present at the first sampling/transfusion, but most variables normalize with intravascular transfusions. Copyright 2005 ISUOG.

  12. Simulation study of axial ultrasound transmission in heterogeneous cortical bone model

    Science.gov (United States)

    Takano, Koki; Nagatani, Yoshiki; Matsukawa, Mami

    2017-07-01

    Ultrasound propagation in a heterogeneous cortical bone was studied. Using a bovine radius, the longitudinal wave velocity distribution in the axial direction was experimentally measured in the MHz range. The bilinear interpolation and piecewise cubic Hermite interpolation methods were applied to create a three-dimensional (3D) precise velocity model of the bone using experimental data. By assuming the uniaxial anisotropy of the bone, the distributions of all elastic moduli of a 3D heterogeneous model were estimated. The elastic finite-difference time-domain method was used to simulate axial ultrasonic wave propagation. The wave propagation in the initial model was compared with that in the thinner model, where the inner part of the cortical bone model was removed. The wave front of the first arriving signal (FAS) slightly depended on the heterogeneity in each model. Owing to the decrease in bone thickness, the propagation behavior also changed and the FAS velocity clearly decreased.

  13. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  14. Studies on the sonosensitization mechanism of ultrasound with ATX-70 in sonodynamic therapy

    Science.gov (United States)

    Ding, Chunfeng; Xing, Da

    2005-01-01

    Sonodynamic therapy (SDT) is an effective method for cure tumors, but its mechanism is not clear up to now. In this work, the mechanism of SDT is analyzed by study the reaction between ultrasound and the gallium-porphyrin analogue ATX-70 experimentally. Results show that the ATX-70 is likely to play three roles in SDT. One is that the sonolumiescence (SL) react with ATX-70 directly, the action of ATX-70 is similarly to a sort of photosensitize. The other is that the high temperature produced in the bubbles at collapse makes ATX-70 into excitated states, the excitated ATX-70 react with the dissolved oxygen in liquid and produce oxygen free radicals. The third is that ATX-70 plays a role of surfactant in the process of cavitation and makes the cavitation become easily, lead to more high-energy hydroxide radicals are produced.

  15. Hyperthermia studies using inductive and ultrasound methods on E. coli bacteria and mouse glioma cells

    Science.gov (United States)

    Cabral-Prieto, A.; López-Callejas, R.; Rodríguez-Méndez, B. G.; Santos-Cuevas, C. L.; Celis-Almazán, J.; Olea-Mejía, O.; Gómez-Morales, J. L.; Peña-Eguiluz, R.; Valencia-Alvarado, R.; Mercado-Cabrera, A.; Muñoz-Castro, A. E.; García-Santibañez, F.

    2017-11-01

    The survival of Escherichia coli bacteria and mouse glioma cells were studied under different temperatures using direct heating in water, ultrasound, and magnetic fluid hyperthermia. The survival of these microorganisms depended on whether the heating mode was continuous or discontinuous, surviving more in the former than in the discontinuous heating mode. Whereas Escherichia coli bacteria did not survive at temperatures ≥50∘C, the mouse glioma cells did not survive at temperatures ≥48∘C. The survival of both these microorganisms was independent of the presence or absence of the magnetic nanoparticles of magnetite, suggesting that these, having mean particle sizes of 9.5, 8.5 and 5, did not show any apparent cytotoxicity effect. Present results also showed that the inductive heating system which used a radiofrequency of 13.56 MHz, providing a maximum magnetic field strength of 160 A/m, the electric rather than magnetic heating predominated.

  16. Hyperthermia studies using inductive and ultrasound methods on E. coli bacteria and mouse glioma cells

    Energy Technology Data Exchange (ETDEWEB)

    Cabral–Prieto, A., E-mail: agustin.cabral@inin.gob.mx; López-Callejas, R., E-mail: regulo.lopez@inin.gob.mx; Rodríguez-Méndez, B. G., E-mail: benjamin.rodriguez@inin.gob.mx; Santos-Cuevas, C. L., E-mail: clara.cuevas@inin.gob.mx [Carretera México-Toluca s/n, La Marquesa, Instituto Nacional de Investigaciones Nucleares (Mexico); Celis-Almazán, J., E-mail: jony-jac-5@hotmail.com; Olea-Mejía, O., E-mail: oleaoscar@yahoo.com.mx [Universidad Autónoma del Estado de México, Centro Conjunto de Investigación en Química Sustentable (Mexico); Gómez-Morales, J. L. [Universidad Autónoma del Estado de México, Campus El Cerrillo, Facultad de Ciencias (Mexico); Peña-Eguiluz, R., E-mail: rosendo.eguiluz@inin.gob.mx; Valencia-Alvarado, R., E-mail: raul.valencia@inin.gob.mx; Mercado-Cabrera, A., E-mail: antonio.mercado@inin.gob.mx; Muñoz-Castro, A. E., E-mail: arturo.munoz@inin.gob.mx [Carretera México-Toluca s/n, La Marquesa, Instituto Nacional de Investigaciones Nucleares (Mexico); García-Santibañez, F., E-mail: fegasa2@yahoo.com.mx [Universidad Autónoma del Estado de México, Campus El Cerrillo, Facultad de Ciencias (Mexico)

    2017-11-15

    The survival of Escherichia coli bacteria and mouse glioma cells were studied under different temperatures using direct heating in water, ultrasound, and magnetic fluid hyperthermia. The survival of these microorganisms depended on whether the heating mode was continuous or discontinuous, surviving more in the former than in the discontinuous heating mode. Whereas Escherichia coli bacteria did not survive at temperatures ≥50{sup ∘}C, the mouse glioma cells did not survive at temperatures ≥48{sup ∘}C. The survival of both these microorganisms was independent of the presence or absence of the magnetic nanoparticles of magnetite, suggesting that these, having mean particle sizes of 9.5, 8.5 and 5, did not show any apparent cytotoxicity effect. Present results also showed that the inductive heating system which used a radiofrequency of 13.56 MHz, providing a maximum magnetic field strength of 160 A/m, the electric rather than magnetic heating predominated.

  17. A comparative study of three speckle reducing methods for intima-media thickness ultrasound images.

    Science.gov (United States)

    Rafati, Mehravar; Arabfard, Masoud; Rafati Rahimzadeh, Mehrdad; Voshtani, Hasan; Moladoust, Hassan

    2015-02-01

    Ultrasonic evaluation of intima-media thickness (IMT) is an early marker of assessing the development of atherosclerosis and determining cardiovascular risk. To attain the best possible diagnosis, it is essential that medical images be clear, sharp and without noise and artifacts. Comparison of speckle reducing anisotropic diffusion (SRAD), discrete (DTD) and continuum topological derivative (CTD) on B-mode ultrasound images of common carotid and brachial arteries throughout the cardiac cycle. In a cross-sectional design, an examination was performed on forty-two human subjects with a mean age of 44 ± 6 years from April 2013 to June 2013. This study was approved by the ethics committees of Kashan University of Medical Sciences and Beheshti Hospital. An ultrasonic examination of common carotid and brachial arteries of forty-two human subjects was performed. The program was designed in MATLAB software to extract consecutive B-mode images and apply region of interest (ROI) on the IMT of the common carotid and brachial arteries. Then, three different noise reduction filters with the Canny edge detection were used in ROI separately. Finally, the program measured the image quality metrics. According to values of eleven different image quality metrics (mentioned in the main text), there was a significant difference between CTD, DTD and SRAD filters with the Canny edge detection status in the common carotid and brachial arteries throughout the cardiac cycle (all P values quality metrics, this study showed that DTD and CTD filters with the Canny edge detection respectively, are better than SRAD filter with the Canny detection for speckle suppression and details preservation in both arteries in the ultrasound images.

  18. Ultrasound-guided thoracic paravertebral block: cadaveric study in foxes (Vulpes vulpes).

    Science.gov (United States)

    Monticelli, Paolo; Jones, Ian; Viscasillas, Jaime

    2017-07-01

    To describe an ultrasound-guided thoracic paravertebral block in canidae. Prospective, experimental, cadaveric study. Twelve thawed fox cadavers. A 15 MHz linear transducer was used to visualize the paravertebral space at the level of the fifth thoracic vertebrae. Iohexol (300 mg mL -1 ) at 0.2 mL kg -1 was injected into the right and left paravertebral spaces under ultrasound guidance using a Tuohy needle. The needle was advanced in a lateral to medial direction using an in-plane technique. Injections were performed by two operators, each performing 12 injections in six fox cadavers. A thoracic computed tomography was then performed and evaluated by a single operator. The following features were recorded: paravertebral contrast location (yes/no), length of contrast column (number of intercostal spaces), location of contrast relative to the fifth thoracic vertebrae (cranial/caudal/mixed), epidural contrast contamination (yes/no), pleural contrast contamination (yes/no) and mediastinal contrast contamination (yes/no). All injections resulted in paravertebral contrast distribution (24/24). The mean length of the contrast column was five intercostal spaces. Contrast spread was caudal to the injection site in 54% (7/24), cranial in 29% (4/24) and mixed in 17% (3/24). Pleural contamination was observed in 50% (12/24) of injections; 42% (10/24) and 4% (1/24) of the injections resulted in mediastinal and epidural contamination, respectively. Injection of the paravertebral space in canidae is possible using the technique described. Possible complications include epidural, pleural and mediastinal contamination. To establish clinical efficacy and safety of this technique, further studies are required. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  19. Mechanism study of dual-frequency ultrasound assisted enzymolysis on rapeseed protein by immobilized Alcalase.

    Science.gov (United States)

    Wang, Bei; Meng, Tingting; Ma, Haile; Zhang, Yanyan; Li, Yunliang; Jin, Jian; Ye, Xiaofei

    2016-09-01

    The mechanism of ultrasound field promoting enzymolysis efficiency is difficult to study, because the reaction system mixes with enzymes, proteins and hydrolysates. Immobilized enzyme is a good option that can be used to investigate the mechanism by separating enzymes out from the system after enzymolysis. The objective of this study was by using immobilized Alcalase to investigate the effects and mechanisms of the promotion of dual-frequency ultrasound (DFU) assisted-enzymolysis on rapeseed protein. Based on single factor experiments, response surface methodology model with three factors - hydrolysis time, power density and solid-liquid ratio at three levels was utilized to optimize the degree of hydrolysis (DH). Circular dichroism (CD) was used to analyze the secondary structure change of the protein, scanning electron microscopy (SEM) was used to analyze the surface microstructure change of the enzyme. The results showed that with DFU assisted-enzymolysis, the DH increased by 74.38% at the optimal levels for power density 57W/L, solid-liquid ratio 5.3g/L and enzymolysis time 76min. After DFU assisted-enzymolysis, the yield of soluble solids content, including protein, peptides and total sugar in hydrolysate increased by 64.61%, 40.88% and 23.60%, respectively. CD analysis showed that after DFU assisted-enzymolysis, the number of α-helix and random coil decreased by 10.7% and 4.5%, β-chain increased by 2.4%. SEM showed that the degree of surface roughness of immobilized Alcalase increased. The above results indicated that the improvement of hydrolysis by DFU assisted-enzymolysis was achieved by enhancing the solid solubility, changing the molecular structure of protein and increased the surface area of immobilized enzyme. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. [Motor behavior of human fetuses during the second trimester of gestation: a longitudinal ultrasound study].

    Science.gov (United States)

    Reynoso, C; Crespo-Eguílaz, N; Alcázar, J L; Narbona, J

    2015-03-01

    The aim of this research is to contribute to knowledge of the normal spontaneous motor behavior of the human fetus during the second trimester of pregnancy. This study focuses on five patterns of spontaneous fetal movement: startle (S), axo-rhizomelic rhythmia (ARR), axial stretching (AS), general movement (GM), and diaphragmatic contraction (DC). A cohort of 13 subjects was followed up using 2D obstetrical ultrasound images at 12, 16, 20, and 24 weeks of gestation. As inclusion criteria, neonatal neurological examination and general movements after eutocic delivery at term were normal in all of the subjects, and their neuromotor and cognitive development until the end of pre-school age were also normal. All these five motor patterns are present at the beginning of the 2(nd) gestational trimester, but their quantitative and qualitative traits are diverse according to gestational ages. The phasic, isolated or rhythmically repeated movements, S and ARR, are prominent at 12 and 16 weeks of gestation, and then their presence gradually diminishes. By contrast, tonic and complex AS and GM movements increase their presence and quality at 20 and 24 weeks. RAR constitute a particular periodic motor pattern not described in previous literature. Moreover, the incidence of DC is progressive throughout the trimester, in clusters of 2-6 arrhythmic and irregular beats. Fetal heart rate increases during fetal motor active periods. All five normal behavioral patterns observed in the ultrasounds reflect the progressive tuning of motor generators in human nervous system during mid-pregnancy. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  2. Formulation and acoustic studies of a new phase-shift agent for diagnostic and therapeutic ultrasound.

    Science.gov (United States)

    Sheeran, Paul S; Luois, Samantha; Dayton, Paul A; Matsunaga, Terry O

    2011-09-06

    Recent efforts in the area of acoustic droplet vaporization with the objective of designing extravascular ultrasound contrast agents has led to the development of stabilized, lipid-encapsulated nanodroplets of the highly volatile compound decafluorobutane (DFB). We developed two methods of generating DFB droplets, the first of which involves condensing DFB gas (boiling point from -1.1 to -2 °C) followed by extrusion with a lipid formulation in HEPES buffer. Acoustic droplet vaporization of micrometer-sized lipid-coated droplets at diagnostic ultrasound frequencies and mechanical indices were confirmed optically. In our second formulation methodology, we demonstrate the formulation of submicrometer-sized lipid-coated nanodroplets based upon condensation of preformed microbubbles containing DFB. The droplets are routinely in the 200-300 nm range and yield microbubbles on the order of 1-5 μm once vaporized, consistent with ideal gas law expansion predictions. The simple and effective nature of this methodology allows for the development of a variety of different formulations that can be used for imaging, drug and gene delivery, and therapy. This study is the first to our knowledge to demonstrate both a method of generating ADV agents by microbubble condensation and formulation of primarily submicrometer droplets of decafluorobutane that remain stable at physiological temperatures. Finally, activation of DFB nanodroplets is demonstrated using pressures within the FDA guidelines for diagnostic imaging, which may minimize the potential for bioeffects in humans. This methodology offers a new means of developing extravascular contrast agents for diagnostic and therapeutic applications. © 2011 American Chemical Society

  3. Breast ultrasound elastography-Results of 193 breast lesions in a prospective study with histopathologic correlation

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Heer, I.; Schaefer, P.J.; Mundhenke, C.; Osterholz, S.; Order, B.M.; Hofheinz, N.; Hedderich, J.; Heller, M.; Jonat, W.; Schreer, I.

    2011-01-01

    Purpose: To evaluate the diagnostic performance of ultrasound elastography in breast masses. Material and methods: 193 lesions (129 benign, 64 malignant) were analyzed with the EUB 8500 Logos-ultrasonic-unit (Hitachi Medical, Japan) and a linear-array-transducer of 7.5-13-MHz. Standard of reference was cytology (FNAfine needle aspiration) or histology (core biopsy). The elastic-score was classified according to a 6-point colour-scale (Ueno classification; 1-3 = benign, 4-5 = malignant). Conventional B-mode ultrasound (US) findings were classified according to the BI-RADS classification. Statistical analysis included sensitivity, specificity, ROC-analysis and kappa-values for intra-/interobserver reliability. Results: The mean score for elasticity was 4.1 ± 0.9 for malignant lesions, and 2.1 ± 1.0 for benign lesions (p < 0.001). With a best cut-off point between elasticity scores 3 and 4, sensitivity was 96.9%, and specificity 76%. Setting a best cut-off point for conventional US between BI-RADS 4 and 5, sensitivity was 57.8%, and specificity 96.1%. Elastography provided higher sensitivity and lower specificity than conventional US, but two lesions with elasticity score 1 were false negative, whereas no lesion scored BI-RADS 1-3 were false negative. ROC-curve was 0.884 for elastography, and 0.820 for conventional US (p < 0.001). Weighted kappa-values for intra-/interobserver reliability were 0.784/0.634 for BI-RADS classification, and 0.720/0.561 for elasticity scores. Conclusion: In our study setting, elastography does not have the potential to replace conventional B-mode US for the detection of breast cancer, but may complement conventional US to improve the diagnostic performance.

  4. Rating scale for the assessment of competence in ultrasound-guided peripheral vascular access - a Delphi Consensus Study.

    Science.gov (United States)

    Primdahl, Stine C; Todsen, Tobias; Clemmesen, Louise; Knudsen, Lars; Weile, Jesper

    2016-09-21

    Peripheral vascular access is vital for treatment and diagnostics of hospitalized patients. Ultrasound-guided vascular access (UGVA) is superior to the landmark technique. To ensure competence-based education, an assessment tool of UGVA competence is needed. We aimed to develop a global rating scale (RS) for assessment of UGVA competence based on opinions on the content from ultrasound experts in a modified Delphi consensus study. We included experts from anesthesiology, emergency medicine and radiology across university hospitals in Denmark. Nine elements were drafted based on existing literature and recommendations from international societies. In a multi-round survey, the experts rated the elements on a five-point Likert scale according to importance, and suggested missing elements. The final Delphi round occurred when >80% of the experts rated all elements ≥4 on the Likert scale. Sixteen experts consented to participate in the study, one withdrew consent prior to the first Delphi round, and 14 completed all three Delphi rounds. In the first Delphi round the experts excluded one element from the scale and changed the content of two elements. In the second Delphi round, the experts excluded one element from the scale. In the third Delphi round, consensus was obtained on the eight elements: preparation of utensils, ergonomics, preparation of the ultrasound device, identification of blood vessels, anatomy, hygiene, coordination of the needle, and completion of the procedure. We developed an RS for assessment of UGVA competence based on opinions of ultrasound experts through a modified Delphi consensus study.

  5. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...

  6. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  7. Disseminated intravascular coagulation in malaria: A case report ...

    African Journals Online (AJOL)

    Disseminated intravascular coagulation (DIC) is seen in <5% of patients with severe Plasmodium falciparum malaria and is more common in cerebral malaria. Here, we report the diagnosis and management of a case of severe P. falciparum malaria with DIC. Keywords: Cerebral malaria, cytokine storm, DIC, heparin ...

  8. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  9. Intravascular catheter sepsis | Mer | South African Medical Journal

    African Journals Online (AJOL)

    Intravascular devices are an integral component of modern-day medical practice. They are used to administer intravenous fluids, medications, blood products and parenteral nutrition. In addition, they serve as a valuable monitor of the haemodynamic status of critically ill patients.

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  12. Pelvic Ultrasound Findings in Women with Obstetric Fistula: A Cross-Sectional Study of Cases and Controls

    Directory of Open Access Journals (Sweden)

    Jeffrey P. Wilkinson

    2018-01-01

    Full Text Available Objective. Obstetric fistula (OF is a morbid condition caused by prolonged obstructed labor. Women with OF experience profound injury and have high rates of infertility and poor obstetric outcomes. We examined endovaginal ultrasound parameters in women with and without OF. Design/Setting/Sample/Methods. This cross-sectional study enrolled women evaluated at the Fistula Care Centre in Lilongwe, Malawi. Eligibility criteria included age 18–45, prior pregnancy, and a uterus on ultrasound. Participants underwent endovaginal ultrasound with measurement of cervical dimensions. Comparisons were done using t-tests and Fisher's exact test. Among women with OF, linear regression was used to assess whether fistula stage was associated with cervical length. Results. We enrolled 98 cases and 12 controls. Women with OF had shorter cervical lengths (18.8 mm versus 27.3 mm, p < 0.01, as well as shorter anterior (7.0 mm versus 9.3 mm, p < 0.01 and posterior (9.5 mm versus 11.0 mm, p < 0.04 cervical stroma, compared to controls. Conclusion. Women with OF have shorter cervical lengths and anterior and posterior cervical stroma, when compared to women without OF. This may offer a partial explanation for subfertility and poor obstetric outcomes in OF patients. Additional studies to clarify the role of ultrasound in OF patients and prediction of future fertility are warranted.

  13. Usefulness of diagnostic ultrasound for detecting myofascial change of the hamstring muscles due to lmmobilization: Experimental study with caged rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yoon Kyoo; Kim, Joo Hyun; Lee, Chang Hyung; Kim, Jung Ryul; Kim, Han Kyum [Korea University College of Medicine, Seoul (Korea, Republic of)

    2002-03-15

    To evaluate the usefulness of diagnostic ultrasound in the localization of soft tissue changes in the region of clinically suspected myofascial pain syndrome and to investigate the ultrasonographic and pathologic differences of the hamstring muscles between caged and freely mobile rabbits. A total of eight caged rabbits were used in this study. Four rabbits (age; two were 3-4 months, and the other two were 8-9 months) were raised in a small cage (40 X 50 X 30 cm), and the other four rabbits (age; two were 3-4 months while the other two 8-9 months) raised in a yard where they were free to move around. First, clinically identified myofascial trigger point-taut band or nodule was identified followed by diagnostic ultrasound examination of the hamstring and gluteus muscles and injection of Indian ink of the band or nodule. Biopsies were performed to include the hyperechoic regions as well as clinically identified myofascial trigger points, and the obtained specimens were stained with hematoxylin-eosin and masson-trichrome. The analysis of the results of the ultrasound study and pathologic study found correlation between the pathologic identification of myofascial trigger point and diagnostic ultrasound, where palpable nodules of caged animal, older more than younger one should greater extent of increment of echogenicity and degenerative pathologic changes such as fatty changes and appearance of hyaline fibers. Diagnostic ultrasound could be applied to identify or observe soft tissue changes in the regions of clinically identified myofascial trigger points. A pattern has emerged where soft tissue changes were ore likely to be observed in the caged animal where their movements were restricted and prone to fixed position. Further study to investigate the reversibility of pathologic changes of caged animal should be carried out.

  14. Usefulness of diagnostic ultrasound for detecting myofascial change of the hamstring muscles due to lmmobilization: Experimental study with caged rabbits

    International Nuclear Information System (INIS)

    Kang, Yoon Kyoo; Kim, Joo Hyun; Lee, Chang Hyung; Kim, Jung Ryul; Kim, Han Kyum

    2002-01-01

    To evaluate the usefulness of diagnostic ultrasound in the localization of soft tissue changes in the region of clinically suspected myofascial pain syndrome and to investigate the ultrasonographic and pathologic differences of the hamstring muscles between caged and freely mobile rabbits. A total of eight caged rabbits were used in this study. Four rabbits (age; two were 3-4 months, and the other two were 8-9 months) were raised in a small cage (40 X 50 X 30 cm), and the other four rabbits (age; two were 3-4 months while the other two 8-9 months) raised in a yard where they were free to move around. First, clinically identified myofascial trigger point-taut band or nodule was identified followed by diagnostic ultrasound examination of the hamstring and gluteus muscles and injection of Indian ink of the band or nodule. Biopsies were performed to include the hyperechoic regions as well as clinically identified myofascial trigger points, and the obtained specimens were stained with hematoxylin-eosin and masson-trichrome. The analysis of the results of the ultrasound study and pathologic study found correlation between the pathologic identification of myofascial trigger point and diagnostic ultrasound, where palpable nodules of caged animal, older more than younger one should greater extent of increment of echogenicity and degenerative pathologic changes such as fatty changes and appearance of hyaline fibers. Diagnostic ultrasound could be applied to identify or observe soft tissue changes in the regions of clinically identified myofascial trigger points. A pattern has emerged where soft tissue changes were ore likely to be observed in the caged animal where their movements were restricted and prone to fixed position. Further study to investigate the reversibility of pathologic changes of caged animal should be carried out.

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Prostate Ultrasound Imaging? Men who have ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  20. Ultrasound -- Vascular

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the ... is specialized and is best performed by a technologist and physician with experience in vascular ultrasound imaging. top of page Additional Information and Resources ...

  1. Surgeon-Performed Ultrasound as Preoperative Localization Study in Patients with Primary Hyperparathyroidism

    NARCIS (Netherlands)

    van Ginhoven, T. M.; Morks, A. N.; Schepers, T.; de Graaf, P. W.; Smit, P. C.

    2011-01-01

    Background: Minimally invasive parathyroidectomy is the treatment of choice for single-gland primary hyperparathyroidism. However, the exact location of the abnormal gland has to be established. Sestamibi scintigraphy, computed tomography and ultrasound (US) are commonly used modalities. We describe

  2. Ultrasound imaging

    International Nuclear Information System (INIS)

    Grant, E.G.; Doherty, F.J.

    1986-01-01

    Diagnostic ultrasound was used as early as 1950 in attempts to detect malignant tumors within the human breast and brain. In the years following, however, little attention was paid to this method of imaging by the radiologic community. Extensive work with this technique was not begun until the 1960s, when bistable ultrasound enabled sonographers to display organ outlines for the first time. Prior to the development of bistable ultrasound, sonographic images were limited to A-mode displays, which were merely a series of amplitude spikes on a graph. Over the past 20 or so years, major advances in ultrasound technology have gradually taken us from the simple graphic A-mode display, through bistable organ outlines, to gray-scale images with excellent parenchymal detail, and finally to real-time ultrasound

  3. The impact of an ultrasound-guided regional anesthesia workshop on resident knowledge: a pilot study.

    Science.gov (United States)

    Ortiz, Jaime

    2012-01-01

    There has been a rapid growth in the use of ultrasound-guided regional anesthesia in the past decade. Residency programs have been trying to find the best way to teach these newer techniques. Our department decided to develop a teaching workshop for our residents with the purpose of improving knowledge and skills in ultrasound-guided regional anesthesia. The hypothesis was that the workshop would improve overall knowledge of ultrasound-guided regional anesthesia as determined by a test developed for this activity. In addition, the goal was to help improve imaging and technical skills. A one-day workshop was organized for the CA1 and CA3 resident classes. The workshop was organized with the following learning objectives: (1) be able to identify basic ultrasound anatomy; (2) learn how to apply principles of ultrasound physics in order to obtain good ultrasound images; (3) develop basic ultrasound imaging skills on human models; and (4) develop needle visualization skills on gel models. The workshop included: a pre-test, a 2-hour didactic session, a 2-hour imaging and skills workshop, and a post-test. A twenty-question exam was developed by our faculty for this activity. A total of 20 residents participated in the two workshops. Tests scores (number correct out of twenty) were 9.5 ± 2.8 for the pre-test and 16.0 ± 1.9 for the post-test (P type of setting. Furthermore, knowledge acquired during the workshop was retained when CA1 residents were re-tested one year after the workshop. The ultrasound-guided regional anesthesia workshop will become part of the didactic series for our CA1 residents and will be a required learning activity. Additional work still needs to be done to find out the best way to test knowledge and skill outcomes in residents learning new technology and techniques.

  4. Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study.

    Science.gov (United States)

    Liccardo, Mattia; Nocerino, Pasquale; Gaia, Salzano; Ciardiello, Carmine

    2018-03-01

    Subclavian access is a reliable technique for lead insertion in pacemaker and defibrillator (ICD) implantation, but it is often accompanied by complications. The aim of this study was to compare the efficacy of the ultrasound-guided axillary approach to the subclavian method. This randomized comparative study was performed on 174 patients: as a first attempt, 116 patients underwent the ultrasound-guided axillary access and 58 patients underwent the subclavian approach. A total of 364 leads were placed. Operators were trained in ultrasound-guided vein access technique. Axillary access was successful in 69% of patients (32/46), in the training phase and, as a first attempt, in 91.4% of patients (106/116), in the randomized phase. When axillary approach failed, we performed the following: subclavian access in 5.2% of patients (6/116), cephalic approach in 2.6% of patients (3/116), surgical method in 0.9% of patients (1/116). The subclavian technique was effective, as a first attempt, in 55 patients (94.8%). When the subclavian access failed, the ultrasound axillary approach successfully performed in all three cases. During a mean follow-up of 18 ± 6 months, the number of lead complications was similar in the subclavian group compared to the axillary group (p = 0.664). As first attempt, ultrasound-guided axillary method showed similarly high-success rate than subclavian approach and well performed when the first attempt in subclavian group failed. Axillary access can be considered a safe and effective alternative technique to the conventional subclavian method for device implantation.

  5. [Obstetrical ultrasound simulator as a tool for improving teaching strategies for beginners: Pilot study and review of the literature].

    Science.gov (United States)

    Chalouhi, G E; Quibel, T; Lamourdedieu, C; Hajal, N J; Gueneuc, A; Benzina, N; Bernardi, V; Ville, Y

    2016-11-01

    The aim of this study was to evaluate the obstetrical ultrasound simulator as an initiation tool for teaching obstetrical ultrasound scanning for beginners. Twenty medical students with no experience in ultrasound scan (US) received a basic theoretical ultrasonography course on US principles and 2nd trimester biometrical measurements. The participants were then divided into 2 groups (A, B). Only group A received a practical 2nd trimester scan training session on the simulator where they were asked to determine fetal and placental position, and to take the 3 biometrical standardized measurements. Group B had the same training session but with a real ultrasound machine and a pregnant volunteer. The 2 groups were then asked to perform an US session on real patients (22 weeks) during which they had to do the same US study. The time needed to complete the whole scan was analyzed. The quality of the measurements was compared based on the previously published Objective Quality Criteria scoring. The mean total score was significantly (P=0.001) better for group A (14.3±1.4) compared to group B 10.3 (±2.75) for group A and B respectively. The time needed to accomplish the whole exam tended to be longer for group A (569±174s) compared to group A (479±104s) (P=0.18). The simulator might be a useful initiation tool to obstetric ultrasound for those who never practiced. It might prove a time sparing procedure in the training process and allow trainees to reach a basic practice level before performing examinations on actual patients. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Delivery of Adeno-Associated Virus Gene Therapy by Intravascular Limb Infusion Methods.

    Science.gov (United States)

    Gruntman, Alisha M; Flotte, Terence R

    2015-09-01

    Recombinant adeno-associated virus (rAAV) can be delivered to the skeletal muscle of the limb (pelvic or thoracic) by means of regional intravascular delivery. This review summarizes the evolution of this technique to deliver rAAV either via the arterial blood supply or via the peripheral venous circulation. The focus of this review is on applications in large animal models, including preclinical studies. Based on this overview of past research, we aim to inform the design of preclinical and clinical studies.

  7. Automated 3D ultrasound elastography of the breast: a phantom validation study

    International Nuclear Information System (INIS)

    Hendriks, Gijs A G M; Holländer, Branislav; Menssen, Jan; Hansen, Hendrik H G; De Korte, Chris L; Milkowski, Andy

    2016-01-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s −1 ) and by three protocols: Go–Go (pre- and post-volumes with identical start and end positions), Go–Return (similar to Go–Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go–Go protocol was shown to be superior with better strain image quality (CNR e and SNR e ) than Go–Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go–Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go–Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to

  8. Utility of common bile duct measurement in emergency department point of care ultrasound: A prospective study.

    Science.gov (United States)

    Lahham, Shadi; Becker, Brent A; Gari, Abdulatif; Bunch, Steven; Alvarado, Maili; Anderson, Craig L; Viquez, Eric; Spann, Sophia C; Fox, John C

    2017-11-18

    Measurement of the common bile duct (CBD) is considered a fundamental component of biliary point-of-care ultrasound (POCUS), but can be technically challenging. The primary objective of this study was to determine whether CBD diameter contributes to the diagnosis of complicated biliary pathology in emergency department (ED) patients with normal laboratory values and no abnormal biliary POCUS findings aside from cholelithiasis. We performed a prospective, observational study of adult ED patients undergoing POCUS of the right upper quadrant (RUQ) and serum laboratory studies for suspected biliary pathology. The primary outcome was complicated biliary pathology occurring in the setting of normal laboratory values and a POCUS demonstrating the absence of gallbladder wall thickening (GWT), pericholecystic fluid (PCF) and sonographic Murphy's sign (SMS). The association between CBD dilation and complicated biliary pathology was assessed using logistic regression to control for other factors, including laboratory findings, cholelithiasis and other sonographic abnormalities. A total of 158 patients were included in the study. 76 (48.1%) received non-biliary diagnoses and 82 (51.9%) were diagnosed with biliary pathology. Complicated biliary pathology was diagnosed in 39 patients. Sensitivity of CBD dilation for complicated biliary pathology was 23.7% and specificity was 77.9%. Of patients diagnosed with biliary pathology, none had isolated CBD dilatation. In the absence of abnormal laboratory values and GWT, PCF or SMS on POCUS, obtaining a CBD measurement is unlikely to contribute to the evaluation of this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Ultrasound therapy for recalcitrant diabetic foot ulcers: results of a randomized, double-blind, controlled, multicenter study.

    Science.gov (United States)

    Ennis, William J; Foremann, Phil; Mozen, Neal; Massey, Joi; Conner-Kerr, Teresa; Meneses, Patricio

    2005-08-01

    An estimated 15% of patients with diabetes will develop a foot ulcer sometime in their life, making them 30 to 40 times more likely to undergo amputation due to a non-healing foot ulcer than the non-diabetic population. To determine the safety and efficacy of a new, non-contact, kilohertz ultrasound therapy for the healing of recalcitrant diabetic foot ulcers - as well as to evaluate the impact on total closure and quantitative bacterial cultures and the effect on healing of various levels of sharp/surgical debridement - a randomized, double-blinded, sham-controlled, multicenter study was conducted in hospital-based and private wound care clinics. Patients (55 met criteria for efficacy analysis) received standard of care, which included products that provide a moist environment, offloading diabetic shoes and socks, debridement, wound evaluation, and measurement. The "therapy" was either active 40 KHz ultrasound delivered by a saline mist or a "sham device" which delivered a saline mist without the use of ultrasound. After 12 weeks of care, the proportion of wounds healed (defined as complete epithelialization without drainage) in the active ultrasound therapy device group was significantly higher than that in the sham control group (40.7% versus 14.3%, P = 0.0366, Fisher's exact test). The ultrasound treatment was easy to use and no difference in the number and type of adverse events between the two treatment groups was noted. Of interest, wounds were debrided at baseline followed by a quantitative culture biopsy. The results of these cultures demonstrated a significant bioburden (greater than 10(5)) in the majority of cases, despite a lack of clinical signs of infection. Compared to control, this therapeutic modality was found to increase the healing rate of recalcitrant, diabetic foot ulcers.

  10. Magnetic resonance imaging-transrectal ultrasound fusion focal cryotherapy of the prostate: A prospective development study.

    Science.gov (United States)

    Valerio, Massimo; Shah, Taimur Tariq; Shah, Paras; Mccartan, Neil; Emberton, Mark; Arya, Manit; Ahmed, Hashim Uddin

    2017-04-01

    The use of software-based magnetic resonance-transrectal ultrasound fusion to deliver focal therapy may increase the precision of treatment. This is a prospective development study assessing the feasibility of Magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion focal cryotherapy. Consecutive patients undergoing focal cryotherapy were included in an academic registry (December 2013-June 2014). MRI-TRUS fusion focal cryotherapy was offered to men with visible clinically significant prostate cancer (Galil SeedNet system). Eligibility was determined by multiparametric MRI (mpMRI), and transperineal template mapping or targeted biopsies. A rigid fusion platform (Biojet) was used with the operator ensuring the ice ball covered at least the lesion. Adverse events were scored using the NCICTC V4. Genitourinary toxicity was assessed using patient-reported outcome measures (IPSS, IIEF-15, and UCLA-EPIC). Early contrast-enhanced MRI and mpMRI at 6 to 12 months were used to assess extent of lesion ablation. Of 23 patients scheduled, 5 did not have image fusion owing to surgeon preference. Overall, 18 patients undergoing image-fusion cryotherapy had median age of 68 (interquartile range [IQR]: 65-73) years and median preoperative prostate-specific antigen = 9.54 (5.65-16)ng/ml. In all, 13 (72.2%) and 5 (27.8%) patients had intermediate and high-risk cancer, respectively. In total, 10 adverse events were reported with one of these as serious (grade 3) because of admission for hematuria requiring wash out only. There was no difference in the IIEF-15 between baseline and study end (P = 0.24). The IPSS remained stable (P = 0.12), whereas the UCLA-EPIC tended to improve (P = 0.065). The prostate-specific antigen level significantly decreased at 1.8 (1.04-2.93) ng/ml (Pcryotherapy is feasible in most patients and seems to accurately guide ablation demonstrated by posttreatment imaging. Additional studies are needed to determine efficacy using postcryotherapy biopsy

  11. LumenRECON Guidewire: Pilot Study of a Novel, Nonimaging Technology for Accurate Vessel Sizing and Delivery of Therapy in Femoropopliteal Disease.

    Science.gov (United States)

    Nair, Pradeep K; Carr, Jeffrey G; Bigelow, Brian; Bhatt, Deepak L; Berwick, Zachary C; Adams, George

    2018-01-01

    Proper vessel sizing during endovascular interventions is crucial to avoid adverse procedural and clinical outcomes. LumenRECON (LR) is a novel, nonimaging, 0.035-inch wire-based technology that uses the physics-based principle of Ohm's law to provide a simple, real-time luminal size while also providing a platform for therapy delivery. This study evaluated the accuracy, reliability, and safety of the LR system in patients presenting for a femoropopliteal artery intervention. This multicenter, prospective pilot study of 24 patients presenting for peripheral intervention compared LR measurements of femoropopliteal artery size to angiographic visual estimation, duplex ultrasound, quantitative angiography, and intravascular ultrasound. The primary effectiveness and safety end point was comparison against core laboratory adjudicated intravascular ultrasound values and major adverse events, respectively. Additional preclinical studies were also performed in vitro and in vivo in swine to determine the accuracy of the LR guidewire system. No intra- or postprocedure device-related adverse events occurred. A balloon or stent was successfully delivered in 12 patients (50%) over the LR wire. Differences in repeatability between successive LR measurements was 2.5±0.40% ( R 2 =0.96) with no significant bias. Differences in measurements of LR to other modalities were 0.5±1.7%, 5.0±1.8%, -1.5±2.0%, and 6.8±3.4% for intravascular ultrasound core laboratory, quantitative angiography, angiographic, and duplex ultrasound, respectively. This study demonstrates that through a physics-based principle, LR provides a real-time, safe, reproducible, and accurate vessel size of the femoropopliteal artery during intervention and can additionally serve as a conduit for therapy delivery over its wire-based platform. © 2018 American Heart Association, Inc.

  12. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... waves from passing into the body. The sonographer (ultrasound technologist) or radiologist then gently presses the transducer against ... performed on an infant, a nurse or radiologic technologist may assist with keeping the ... procedure? Ultrasound examinations are painless and easily tolerated by most ...

  13. Results of the ICTuS 2 Trial (Intravascular Cooling in the Treatment of Stroke 2).

    Science.gov (United States)

    Lyden, Patrick; Hemmen, Thomas; Grotta, James; Rapp, Karen; Ernstrom, Karin; Rzesiewicz, Teresa; Parker, Stephanie; Concha, Mauricio; Hussain, Syed; Agarwal, Sachin; Meyer, Brett; Jurf, Julie; Altafullah, Irfan; Raman, Rema

    2016-12-01

    Therapeutic hypothermia is a potent neuroprotectant approved for cerebral protection after neonatal hypoxia-ischemia and cardiac arrest. Therapeutic hypothermia for acute ischemic stroke is safe and feasible in pilot trials. We designed a study protocol to provide safer, faster therapeutic hypothermia in stroke patients. Safety procedures and 4°C saline infusions for faster cooling were added to the ICTuS trial (Intravascular Cooling in the Treatment of Stroke) protocol. A femoral venous intravascular cooling catheter after intravenous recombinant tissue-type plasminogen activator in eligible patients provided 24 hours cooling followed by a 12-hour rewarm. Serial safety assessments and imaging were performed. The primary end point was 3-month modified Rankin score 0,1. Of the intended 1600 subjects, 120 were enrolled before the study was stopped. Randomly, 63 were to receive hypothermia plus antishivering treatment and 57 normothermia. Compared with previous studies, cooling rates were improved with a cold saline bolus, without fluid overload. The intention-to-treat primary outcome of 90-day modified Rankin Score 0,1 occurred in 33% hypothermia and 38% normothermia subjects, odds ratio (95% confidence interval) of 0.81 (0.36-1.85). Serious adverse events occurred equally. Mortality was 15.9% hypothermia and 8.8% normothermia subjects, odds ratio (95% confidence interval) of 1.95 (0.56-7.79). Pneumonia occurred in 19% hypothermia versus 10.5% in normothermia subjects, odds ratio (95% confidence interval) of 1.99 (0.63-6.98). Intravascular therapeutic hypothermia was confirmed to be safe and feasible in recombinant tissue-type plasminogen activator-treated acute ischemic stroke patients. Protocol changes designed to reduce pneumonia risk appeared to fail, although the sample is small. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01123161. © 2016 American Heart Association, Inc.

  14. A validation of the first genome-wide association study of calcaneus ultrasound parameters in the European Male Ageing Study

    Directory of Open Access Journals (Sweden)

    Han Thang S

    2011-01-01

    Full Text Available Abstract Background A number of single nucleotide polymorphisms (SNPs have been associated with broadband ultrasound attenuation (BUA and speed of sound (SOS as measured by quantitative ultrasound (QUS at the calcaneus in the Framingham 100K genome-wide association study (GWAS but have not been validated in independent studies. The aim of this analysis was to determine if these SNPs are associated with QUS measurements assessed in a large independent population of European middle-aged and elderly men. The association between these SNPs and bone mineral density (BMD measured using dual-energy X-ray absorptiometry (DXA was also tested. Methods Men aged 40-79 years (N = 2960 were recruited from population registers in seven European centres for participation in an observational study of male ageing, the European Male Ageing Study (EMAS. QUS at the calcaneus was measured in all subjects and blood was taken for genetic analysis. Lumbar spine (LS, femoral neck (FN and total hip (TH BMD were measured by DXA in a subsample of 620 men in two centres. SNPs associated with BUA or SOS in the Framingham study with p -4 were selected and genotyped using SEQUENOM technology. Linear regression was used to test for the association between SNPs and standardised (SD bone outcomes under an additive genetic model adjusting for centre. The same direction of effect and p Results Thirty-four of 38 selected SNPs were successfully genotyped in 2377 men. Suggestive evidence of replication was observed for a single SNP, rs3754032, which was associated with a higher SOS (β(SD = 0.07, p = 0.032 but not BUA (β(SD = 0.02, p = 0.505 and is located in the 3'UTR of WDR77 (WD repeat domain 77 also known as androgen receptor cofactor p44. A single SNP, rs238358, was associated with BMD at the LS (β(SD = -0.22, p = 0.014, FN (β(SD = -0.31,p = 0.001 and TH (β(SD = -0.36, p = 0.002 in a locus previously associated with LS BMD in large-scale GWAS, incorporating AKAP11 and RANKL

  15. Ultrasound-guided epidural catheter placement with a new technique: preliminary cadaveric study.

    Directory of Open Access Journals (Sweden)

    Elisa Silvia D'Urso

    2017-05-01

    Full Text Available Several methods are described in veterinary medicine to perform and assess correct epidural needle placement to provide effective epidural analgesia (Adami et al 2017. The aim of this study is to evaluate the feasibility of an ultrasound longitudinal sagittal approach to epidural catheter placement using a biopsy needle guide. Seven dog cadavers were used in the study. With the cadaver in sternal recumbence, a 5-8 MHz microconvex transducer provided with a 16-gauge biopsy guide was positioned to obtain a longitudinal sagittal scan of the spinal process of L7 and the sacral crest; the epidural space was identified between two parallel hyperechoic lines and, as the trajectory of the biopsy guide crossed them, a 17G Tuohy needle was used to insert a 19G epidural catheter. Correct catheter placement was visualised through a resection of the column between L2 and L3. Firstly, an expert echographist (operator C1 visualised the ultrasonographic landmarks, while catheter placement was performed by an expert anaesthetist (operator A, a student (operator B and another expert echographist (operator C2 (double-operator technique; secondly, operator A and C2 performed alone the whole procedure (single-operator technique; lastly all operators performed a blind procedure (Jones 2001. Operator A failed 2/7 single-operator procedures; time to perform the blind technique was statistically lower than the double-operator technique (75 ± 132.4 vs 91.6 ± 79.3 seconds. Operator C2 failed 3/7 blind procedures, scoring the higher total time of performance (329.3 ± 271.2 seconds, but was able to perform both the double- and single-operator technique without significant difference with operator A, despite a faster time in positioning the probe. Operator B showed a higher repositioning attempts of the needle with the double-operator procedure compared to the blind one. Ultrasound guidance appears to be a promising technique to ease catheter placement also by operators

  16. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. [The correlation study on syndrome differentiation of rheumatoid arthritis and joint high frequency ultrasound performance].

    Science.gov (United States)

    Bi, Ya-Nan; Xiao, Chang-Hong; Pan, Chao; Zhao, Xiao-Feng; Cao, Yan-Yan; Yuan Yi; Zuo, Fang-Fang

    2015-01-01

    To observe the differential effect of joint ultrasound on the syndrome differentiation of rheumatoid arthritis (RA) by observing the high frequency ultrasound performances among inactive stage and different syndromes in active stage. Totally 83 RA patients in the active stage were assigned to the dampness heat syndrome group (DHS, 59 cases)and the cold dampness syndrome group (CDS, 24 cases) according to Chinese medicine (CM) syndrome typing. Besides, 20 RA patients in the remission stage were recruited as the control group (abbreviated as the remission group). By using high frequency ultrasound and power Doppler ultrasound technology, a comparative observation of synovitis, tenosynovitis, synovial blood flow, and bone erosion in the 2nd-5th metacarpophalangeal (MCP) joints, proximal interphalangeal (PIP) joints, wrist joints, knee joints, the second and the fifth metatarsophalangeal (MTP) joints (a total of 24 joints) was performed in all patients. Correlation analyses were performed between the ultrasound performance, laboratory indices, and the disease activity. Ultrasound data of each RA patient were analyzed by their total scores. Χ2 test was used for enumeration data. The measurement data was expressed as x ± s. One-way ANOVA was used for data of normal distribution, while non- parametric test was used for data of non-normal distribution. Correlation analysis of two variables was performed for clinical indicators and ultrasound indicators. Its significance was detected using Pearson correlation. Compared with the remission group, the severity degree of synovitis, tenosynovitis, synovial blood flow, and bone erosion significantly increased in the DHS group (P 0.05). There existed positive correlation between ESR and the synovitis degree, synovial blood flow, and bone erosion in the DHS group (r = 0.444, 0.397, 0.486, P syndrome differentiation of RA patients.

  18. Tolerance of low-frequency ultrasound sonophoresis: a double-blind randomized study on humans.

    Science.gov (United States)

    Maruani, Annabel; Vierron, Emilie; Machet, Laurent; Giraudeau, Bruno; Halimi, Jean-Michel; Boucaud, Alain

    2012-05-01

    Sonophoresis [low-frequency ultrasound (US)] has been used in animals and in vitro to investigate enhanced percutaneous absorption of drugs. No study focused on its clinical human tolerance has been published as yet. We aimed to assess the bioeffects of low-frequency US in vivo on human skin in a double-blind randomized-controlled study. We applied pulse-mode US at 36 kHz for 5 min in a step procedure of increasing dosage, from 1.57 to 3.50 W/cm(2), and placebo. The primary outcome was toxic effects of the procedure, defined as a pain score >40 on a 0-100 mm visual analogue scale or necrosis. Erythema (scored from 0 to 3 in severity) was also evaluated. The secondary outcomes were measurements of skin thickness by high-resolution skin imaging, of skin capacitance and temperature. We included 34 healthy volunteers. We found no pain score >38 and no skin necrosis with either US or placebo. Erythema was systematically observed immediately after US application, but after 1 day, we observed three cases in the knee group. The most frequent adverse effect was tinnitus. We observed no marked increase in temperature or cutaneous thickness after US or placebo. Cutaneous capacitance increased immediately after both applications. Such data demonstrating good tolerance of sonophoresis can be useful before the initiation of a clinical trial of the therapeutic use of low-frequency sonophoresis in humans. © 2011 John Wiley & Sons A/S.

  19. Hippocampal development at gestation weeks 23 to 36. An ultrasound study on preterm neonates

    Energy Technology Data Exchange (ETDEWEB)

    Bajic, Dragan; Raininko, Raili [Uppsala University, Department of Radiology, University Hospital, Uppsala (Sweden); Ewald, Uwe [Uppsala University, Department of Women' s and Children' s Health, Uppsala (Sweden)

    2010-06-15

    During fetal development, the hippocampal structures fold around the hippocampal sulcus into the temporal lobe. According to the literature, this inversion should be completed at gestation week (GW) 21. Thereafter, the hippocampal shape should resemble the adult shape. However, incomplete hippocampal inversion (IHI) is found in 19% of the common population. The aim of this study was to study fetal hippocampal development by examining neonates born preterm. We analyzed cranial ultrasound examinations, performed as a part of the routine assessment of all preterm infants, over a 3-year period and excluded the infants with brain pathology. The final material consisted of 158 children born <35 GW. A rounded form (the ratio between the horizontal and vertical diameters of the hippocampal body {<=}1) in coronal slices was considered the sign of IHI. The age at examination was 23-24 GW in 24 neonates, 25-28 GW in 70 neonates, and 29-36 GW in 64 neonates. IHI was found in 50%, 24%, and 14%, respectively. The difference between the neonates <25 GW and {>=}25 GW was statistically highly significant (p < 0.001). The frequency of bilateral IHI was highest in the youngest age group. In the other groups, the left-sided IHI was the most common. In about 50% of the neonates, hippocampal inversion is not completed up to GW 24; but from 25 GW onwards, the frequency and laterality of IHI is similar to that in the adult population. (orig.)

  20. Ultrasound lung comets induced by repeated breath-hold diving, a study in underwater fishermen.

    Science.gov (United States)

    Boussuges, A; Coulange, M; Bessereau, J; Gargne, O; Ayme, K; Gavarry, O; Fontanari, P; Joulia, F

    2011-12-01

    Pulmonary edema has been reported in breath-hold divers during fish-catching diving activity. The present study was designed to detect possible increases in extravascular lung water (EVLW) in underwater fishermen after a competition. Thirty healthy subjects were studied. They participated in two different 5-h fish-catching diving competitions: one organized in the winter (10 subjects) and one organized in the autumn (20 subjects). A questionnaire was used to record underwater activity and note respiratory problems. An increase in EVLW was investigated from the detection of ultrasound lung comets (ULC) by chest ultrasonography. Complementary investigations included echocardiography and pulmonary function testing. An increase in EVLW was detected in three out of 30 underwater fishermen after the competition. No signs of cardiovascular dysfunction were found in the entire population and in divers with an increase in the ULC score. Two divers with raised ULC presented respiratory disorders such as cough or shortness of breath. Impairment in spirometric parameters was recorded in these subjects. An increase in EVLW could be observed after a fish-catching diving competition in three out of 30 underwater fishermen. In two subjects, it was related to respiratory disorders and impairment in pulmonary flow. © 2011 John Wiley & Sons A/S.

  1. Detecting hepatic steatosis using ultrasound-induced thermal strain imaging: an ex vivo animal study

    Science.gov (United States)

    Mahmoud, Ahmed M.; Ding, Xuan; Dutta, Debaditya; Singh, Vijay P.; Kim, Kang

    2014-01-01

    Hepatic steatosis or fatty liver disease occurs when lipids accumulate within the liver and can lead to steatohepatitis, cirrhosis, liver cancer, and eventual liver failure requiring liver transplant. Conventional brightness mode (B-mode) ultrasound (US) is the most common noninvasive diagnostic imaging modality used to diagnose hepatic steatosis in clinics. However, it is mostly subjective or requires a reference organ such as the kidney or spleen with which to compare. This comparison can be problematic when the reference organ is diseased or absent. The current work presents an alternative approach to noninvasively detecting liver fat content using ultrasound-induced thermal strain imaging (US-TSI). This technique is based on the difference in the change in the speed of sound as a function of temperature between water- and lipid-based tissues. US-TSI was conducted using two system configurations including a mid-frequency scanner with a single linear array transducer (5-14 MHz) for both imaging and heating and a high-frequency (13-24 MHz) small animal imaging system combined with a separate custom-designed US heating transducer array. Fatty livers (n=10) with high fat content (45.6 ± 11.7%) from an obese mouse model and control livers (n=10) with low fat content (4.8± 2.9%) from wild-type mice were embedded in gelatin. Then, US imaging was performed before and after US induced heating. Heating time periods of ~3 s and ~9.2 s were used for the mid-frequency imaging and high-frequency imaging systems, respectively to induce temperature changes of approximately 1.5 °C. The apparent echo shifts that were induced as a result of sound speed change were estimated using 2D phase-sensitive speckle tracking. Following US-TSI, histology was performed to stain lipids and measure percentage fat in the mouse livers. Thermal strain measurements in fatty livers (−0.065±0.079%) were significantly (p<0.05) higher than those measured in control livers (−0.124±0

  2. High-frequency ultrasound for intraoperative margin assessments in breast conservation surgery: a feasibility study

    Directory of Open Access Journals (Sweden)

    Hart Vern P

    2011-10-01

    Full Text Available Abstract Background In addition to breast imaging, ultrasound offers the potential for characterizing and distinguishing between benign and malignant breast tissues due to their different microstructures and material properties. The aim of this study was to determine if high-frequency ultrasound (20-80 MHz can provide pathology sensitive measurements for the ex vivo detection of cancer in margins during breast conservation surgery. Methods Ultrasonic tests were performed on resected margins and other tissues obtained from 17 patients, resulting in 34 specimens that were classified into 15 pathology categories. Pulse-echo and through-transmission measurements were acquired from a total of 57 sites on the specimens using two single-element 50-MHz transducers. Ultrasonic attenuation and sound speed were obtained from time-domain waveforms. The waveforms were further processed with fast Fourier transforms to provide ultrasonic spectra and cepstra. The ultrasonic measurements and pathology types were analyzed for correlations. The specimens were additionally re-classified into five pathology types to determine specificity and sensitivity values. Results The density of peaks in the ultrasonic spectra, a measure of spectral structure, showed significantly higher values for carcinomas and precancerous pathologies such as atypical ductal hyperplasia than for normal tissue. The slopes of the cepstra for non-malignant pathologies displayed significantly greater values that differentiated them from the normal and malignant tissues. The attenuation coefficients were sensitive to fat necrosis, fibroadenoma, and invasive lobular carcinoma. Specificities and sensitivities for differentiating pathologies from normal tissue were 100% and 86% for lobular carcinomas, 100% and 74% for ductal carcinomas, 80% and 82% for benign pathologies, and 80% and 100% for fat necrosis and adenomas. Specificities and sensitivities were also determined for differentiating each

  3. High-frequency ultrasound for intraoperative margin assessments in breast conservation surgery: a feasibility study

    International Nuclear Information System (INIS)

    Doyle, Timothy E; Neumayer, Leigh A; Factor, Rachel E; Ellefson, Christina L; Sorensen, Kristina M; Ambrose, Brady J; Goodrich, Jeffrey B; Hart, Vern P; Jensen, Scott C; Patel, Hemang

    2011-01-01

    In addition to breast imaging, ultrasound offers the potential for characterizing and distinguishing between benign and malignant breast tissues due to their different microstructures and material properties. The aim of this study was to determine if high-frequency ultrasound (20-80 MHz) can provide pathology sensitive measurements for the ex vivo detection of cancer in margins during breast conservation surgery. Ultrasonic tests were performed on resected margins and other tissues obtained from 17 patients, resulting in 34 specimens that were classified into 15 pathology categories. Pulse-echo and through-transmission measurements were acquired from a total of 57 sites on the specimens using two single-element 50-MHz transducers. Ultrasonic attenuation and sound speed were obtained from time-domain waveforms. The waveforms were further processed with fast Fourier transforms to provide ultrasonic spectra and cepstra. The ultrasonic measurements and pathology types were analyzed for correlations. The specimens were additionally re-classified into five pathology types to determine specificity and sensitivity values. The density of peaks in the ultrasonic spectra, a measure of spectral structure, showed significantly higher values for carcinomas and precancerous pathologies such as atypical ductal hyperplasia than for normal tissue. The slopes of the cepstra for non-malignant pathologies displayed significantly greater values that differentiated them from the normal and malignant tissues. The attenuation coefficients were sensitive to fat necrosis, fibroadenoma, and invasive lobular carcinoma. Specificities and sensitivities for differentiating pathologies from normal tissue were 100% and 86% for lobular carcinomas, 100% and 74% for ductal carcinomas, 80% and 82% for benign pathologies, and 80% and 100% for fat necrosis and adenomas. Specificities and sensitivities were also determined for differentiating each pathology type from the other four using a multivariate

  4. Multi-parametric monitoring and assessment of High Intensity Focused Ultrasound (HIFU) boiling by Harmonic Motion Imaging for Focused Ultrasound (HMIFU): An ex vivo feasibility study

    Science.gov (United States)

    Hou, Gary Y.; Marquet, Fabrice; Wang, Shutao; Konofagou, Elisa E.

    2014-01-01

    Harmonic Motion Imaging for Focused Ultrasound (HMIFU) is a recently developed high-intensity focused ultrasound (HIFU) treatment monitoring method with feasibilities demonstrated in vitro and in vivo. Here, a multi-parametric study is performed to investigate both elastic and acoustics-independent viscoelastic tissue changes using the Harmonic Motion Imaging (HMI) displacement, axial compressive strain and change in relative phase-shift during high energy HIFU treatment with tissue boiling. Forty three (n=43) thermal lesions were formed in ex vivo canine liver specimens (n=28). Two dimensional (2D) transverse HMI displacement maps were also obtained before and after lesion formation. The same method was repeated in 10-s, 20-s and 30-s HIFU durations at three different acoustic powers of 8, 10, and 11W, which were selected and verified as treatment parameters capable of inducing boiling using both thermocouple and Passive Cavitation Detection (PCD) measurements. Although a steady decrease in the displacement, compressive strain, and relative change in the focal phase shift (Δφ) were obtained in numerous cases, indicating an overall increase in relative stiffness, the study outcomes also showed that during boiling, a reverse lesion-to-background displacement contrast was detected, indicating potential change in tissue absorption, geometrical change and/or, mechanical gelatification or pulverization. Following treatment, corresponding 2D HMI displacement images of the thermal lesions also mapped consistent discrepancy in the lesion-to-background displacement contrast. Despite unpredictable changes in acoustic properties with boiling, the relative change in phase shift showed a consistent decrease, indicating its robustness to monitor biomechanical properties independent of the acoustic property change throughout the HIFU treatment. In addition, the 2D HMI displacement images confirmed and indicated the increase in the thermal lesion size with treatment duration

  5. Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

    Science.gov (United States)

    Hou, Gary Y; Marquet, Fabrice; Wang, Shutao; Konofagou, Elisa E

    2014-03-07

    Harmonic motion imaging for focused ultrasound (HMIFU) is a recently developed high-intensity focused ultrasound (HIFU) treatment monitoring method with feasibilities demonstrated in vitro and in vivo. Here, a multi-parametric study is performed to investigate both elastic and acoustics-independent viscoelastic tissue changes using the Harmonic Motion Imaging (HMI) displacement, axial compressive strain and change in relative phase shift during high energy HIFU treatment with tissue boiling. Forty three (n = 43) thermal lesions were formed in ex vivo canine liver specimens (n = 28). Two-dimensional (2D) transverse HMI displacement maps were also obtained before and after lesion formation. The same method was repeated in 10 s, 20 s and 30 s HIFU durations at three different acoustic powers of 8, 10, and 11 W, which were selected and verified as treatment parameters capable of inducing boiling using both thermocouple and passive cavitation detection (PCD) measurements. Although a steady decrease in the displacement, compressive strain, and relative change in the focal phase shift (Δϕ) were obtained in numerous cases, indicating an overall increase in relative stiffness, the study outcomes also showed that during boiling, a reverse lesion-to-background displacement contrast was detected, indicating potential change in tissue absorption, geometrical change and/or, mechanical gelatification or pulverization. Following treatment, corresponding 2D HMI displacement images of the thermal lesions also mapped consistent discrepancy in the lesion-to-background displacement contrast. Despite the expectedly chaotic changes in acoustic properties with boiling, the relative change in phase shift showed a consistent decrease, indicating its robustness to monitor biomechanical properties independent of the acoustic property changes throughout the HIFU treatment. In addition, the 2D HMI displacement images confirmed and indicated the increase in the thermal lesion size with

  6. Numerical Study and Optimisation of a Novel Single-Element Dual-Frequency Ultrasound Transducer

    Directory of Open Access Journals (Sweden)

    Changhe Sun

    2018-02-01

    Full Text Available A dual-frequency ultrasound transducer (DFUT is usually preferred for its numerous advantageous applications, especially in biomedical imaging and sensing. However, most of DFUTs are based on the combination of fundamental and harmonic operations, or integration of multiple different single-frequency ultrasound transducers, hindering perfect beam alignment and acoustic impedance matching. A novel single-element DFUT has been proposed in this paper. A small piezoelectric membrane is used as the high-frequency ultrasound transducer, which is stacked on a large non-piezoelectric elastic membrane with a groove used as the low-frequency capacitive ultrasound transducer. Such a capacitive-piezoelectric hybrid structure is theoretically analysed in details, based on the electrostatic attraction force and converse piezoelectric effect. Both the low and high resonance frequencies are independently derived, with a maximum deviation of less than 4% from the finite element simulations. Besides, a lumped-parameter equivalent circuit model of combining both the capacitive and piezoelectric ultrasound transducers was also described. Based on our dual-frequency structure design, a high-to-low frequency ratio of about 2 to more than 20 could be achieved, with easy and independent controllability of two frequencies, and the high-frequency operation shows at least an order-of-magnitude displacement sensitivity improvement compared with the conventional harmonic operations.

  7. Polymer coating embolism from intravascular medical devices - a clinical literature review.

    Science.gov (United States)

    Chopra, Amitabh M; Mehta, Monik; Bismuth, Jean; Shapiro, Maksim; Fishbein, Michael C; Bridges, Alina G; Vinters, Harry V

    Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated devices have been increasingly adopted by interventional physicians and vascular surgeons to access and treat a wider range of clinical presentations. Recent clinical literature highlights the presence of polymer coating emboli within the anatomy - a result of coating separation from an intravascular device - and associates it with a range of adverse clinical sequelae. The 2015 U.S. Food and Drug Administration safety communication titled "Lubricious Coating Separation from Intravascular Medical Devices" acknowledges these concerns and concludes that it will work with stakeholders to develop nonclinical test methodologies, establish performance criteria, and identify gaps in current national and international device standards for coating integrity performance. Despite this communication and multiple case reports from interventional physicians, pathologists, dermatologists and other involved physician specialties, polymer coating embolism remains clinically underrecognized. This article consolidates the available literature on polymer coating embolism (1986-2016) and highlights the following relevant information for the physician: (a) the history and elusive nature of polymer coating embolism; (b) potential incidence rates of this phenomenon; (c) reported histologic findings and clinical effects of polymer emboli in the anatomy; (d) the importance of the collaborative clinician-pathologist partnership to report polymer embolism findings; and (e) the importance to study particulate release from intravascular devices so as to further understand and potentially evolve coated interventional technologies. Preliminary research on coatings highlights the potential of using iterations of coatings on medical devices that attain the desired therapeutic result and mitigate or eliminate particulates altogether. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Zerkowski Hans-Reinhard

    2006-05-01

    Full Text Available Abstract Background In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. Methods In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. Results A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. Conclusion Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.

  9. Functional intravascular volume deficit in patients before surgery

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Jørgensen, C C; Secher, N H

    2010-01-01

    limited data on the volume required to establish a maximal SV before the start of surgery. Therefore, we estimated the occurrence and size of the potential functional intravascular volume deficit in surgical patients. METHODS: Patients scheduled for mastectomy (n=20), open radical prostatectomy (n=20......BACKGROUND: Stroke volume (SV) maximization with a colloid infusion, referred to as individualized goal-directed therapy, improves outcome in high-risk surgery. The fraction of patients who need intravascular volume to establish a maximal SV has, however, not been evaluated, and there are only...... deficit. RESULTS: Forty-two (70%) of the patients needed volume to establish a maximal SV. For the patients needing volume, the required amount was median 200 ml (range 200-600 ml), with no significant difference between the three groups of patients. The required volume was >or=400 ml in nine patients (15...

  10. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  11. Feasibility study on photoacoustic guidance for high-intensity focused ultrasound-induced hemostasis

    Science.gov (United States)

    Nguyen, Van Phuc; Kim, Jeehyun; Ha, Kang-lyeol; Oh, Junghwan; Kang, Hyun Wook

    2014-10-01

    The feasibility of photoacoustic imaging (PAI) application was evaluated to map punctured blood vessels thermally treated by high-intensity focused ultrasound (HIFU) for hemostasis. A single-element HIFU transducer with a central frequency of 2.0 MHz, was used to induce thermal hemostasis on the punctured arteries. The HIFU-treated lesion was imaged and localized by high-contrast PAI guidance. The results showed that complete hemostasis was achieved after treatment of the damaged blood vessels within 25 to 52 s at the acoustic intensity of 3600 W/cm2. The coagulation time for the animal artery was ˜20% longer than that of the phantom possibly due to a lower Young's modulus. The reconstructed PA images were able to distinguish the treated area from the surrounding tissue in terms of augmented signal amplitudes (up to three times). Spectroscopic studies demonstrated that the optimal imaging wavelength was found to be 700 nm in order to reconstruct high-contrast photoacoustic images on HIFU-treated lesions. The proposed PAI integrated with HIFU treatment can be a feasible application to obtain safe and rapid hemostasis for acute arterial bleeding.

  12. Numerical study of thermoviscous effects in ultrasound-induced acoustic streaming in microchannels.

    Science.gov (United States)

    Muller, Peter Barkholt; Bruus, Henrik

    2014-10-01

    We present a numerical study of thermoviscous effects on the acoustic streaming flow generated by an ultrasound standing-wave resonance in a long straight microfluidic channel containing a Newtonian fluid. These effects enter primarily through the temperature and density dependence of the fluid viscosity. The resulting magnitude of the streaming flow is calculated and characterized numerically, and we find that even for thin acoustic boundary layers, the channel height affects the magnitude of the streaming flow. For the special case of a sufficiently large channel height, we have successfully validated our numerics with analytical results from 2011 by Rednikov and Sadhal for a single planar wall. We analyzed the time-averaged energy transport in the system and the time-averaged second-order temperature perturbation of the fluid. Finally, we have made three main changes in our previously published numerical scheme to improve the numerical performance: (i) The time-averaged products of first-order variables in the time-averaged second-order equations have been recast as flux densities instead of as body forces. (ii) The order of the finite-element basis functions has been increased in an optimal manner. (iii) Based on the International Association for the Properties of Water and Steam (IAPWS 1995, 2008, and 2011), we provide accurate polynomial fits in temperature for all relevant thermodynamic and transport parameters of water in the temperature range from 10 to 50 °C.

  13. Novel ultrasound-guided inter-semispinal plane block: a comparative pilot study in healthy volunteers.

    Science.gov (United States)

    Ohgoshi, Yuichi; Nishizakura, Ryo; Takahashi, Yuki; Takeda, Keisuke; Nakayama, Hirosuke; Kawamata, Mariko; Kurahashi, Kiyoyasu

    2018-02-01

    We previously reported that a novel multifidus cervicis plane (MCP) block could anesthetize the dorsal rami of the cervical spinal nerves. While MCP sonoanatomy is easily detectable in most patients, it is sometimes difficult to recognize the MCP injection plane, especially in elderly patients. Thus, we proposed the inter-semispinal plane (ISP) block as an alternative for the MCP block. The aim of this study was to evaluate the utility of the ISP block by evaluating the area and duration of anesthesia, compared with that of the MCP block in eight healthy volunteers. Each participant underwent unilateral ultrasound-guided MCP block and ISP block. For each block, 20 ml of ropivacaine 0.2% was injected, and the area of anesthesia was determined using the pinprick test. The anesthetic area ranged from C4 to T2 (3/8; 37.5%), T3 (2/8; 25%), or T4 (3/8; 37.5%) in the MCP block, and from C4 to T1 (1/8; 12.5%), T2 (3/8; 37.5%), T3 (2/8; 25%), or T4 (1/8; 12.5%) in the ISP block. The mean (standard deviation) duration of sensory loss following MCP and ISP blocks was 329 (77) min and 349 (70) min, respectively. Thus, the ISP block may be a reliable alternative to the MCP block.

  14. Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study.

    Science.gov (United States)

    Piscaglia, Fabio; Salvatore, Veronica; Mulazzani, Lorenzo; Cantisani, Vito; Colecchia, Antonio; Di Donato, Roberto; Felicani, Cristina; Ferrarini, Alessia; Gamal, Nesrine; Grasso, Valentina; Marasco, Giovanni; Mazzotta, Elena; Ravaioli, Federico; Ruggieri, Giacomo; Serio, Ilaria; Sitouok Nkamgho, Joules Fabrice; Serra, Carla; Festi, Davide; Schiavone, Cosima; Bolondi, Luigi

    2017-07-01

    Whether Fibroscan thresholds can be immediately adopted for none, some or all other shear wave elastography techniques has not been tested. The aim of the present study was to test the concordance of the findings obtained from 7 of the most recent ultrasound elastography machines with respect to Fibroscan. Sixteen hepatitis C virus-related patients with fibrosis ≥2 and having reliable results at Fibroscan were investigated in two intercostal spaces using 7 different elastography machines. Coefficients of both precision (an index of data dispersion) and accuracy (an index of bias correction factors expressing different magnitudes of changes in comparison to the reference) were calculated. Median stiffness values differed among the different machines as did coefficients of both precision (range 0.54-0.72) and accuracy (range 0.28-0.87). When the average of the measurements of two intercostal spaces was considered, coefficients of precision significantly increased with all machines (range 0.72-0.90) whereas of accuracy improved more scatteredly and by a smaller degree (range 0.40-0.99). The present results showed only moderate concordance of the majority of elastography machines with the Fibroscan results, preventing the possibility of the immediate universal adoption of Fibroscan thresholds for defining liver fibrosis staging for all new machines. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. A study on changes in body surface temperature and thermal effect according to ultrasound mode

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Sung Hee [Dept. of Radiology, Ilsin Christian Hospital, Busan (Korea, Republic of); Lee, Jin Soo [Dept. of Radiology, University Haeundae Paik Hospital, Busan (Korea, Republic of)

    2017-06-15

    Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different(p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

  16. The Feasibility of Contrast-Enhanced Ultrasound During Uterine Artery Embolization: A Pilot Study

    International Nuclear Information System (INIS)

    Dorenberg, Eric J.; Jakobsen, Jarl A.; Brabrand, Knut; Hafsahl, Geir; Smith, Hans-Jorgen

    2007-01-01

    Purpose. To evaluate the feasibility of using contrast-enhanced ultrasound (CEUS) during uterine artery embolization (UAE) in order to define the correct end-point of embolization with complete devascularization of all fibroids. Methods. In this prospective study of 10 consecutive women undergoing UAE, CEUS was performed in the angiographic suite during embolization. When the angiographic end-point, defined as the 'pruned-tree' appearance of the uterine arteries was reached, CEUS was performed while the angiographic catheters to both uterine arteries were kept in place. The decision whether or not to continue the embolization was based on the findings at CEUS. The results of CEUS were compared with those of contrast-enhanced magnetic resonance imaging (MRI) 1 day as well as 3 months following UAE. Results. CEUS was successfully performed in all women. In 4 cases injection of particles was continued based on the findings at CEUS despite angiographically complete embolization. CEUS imaging at completion of UAE correlated well with the findings at MRI. Conclusion. The use of CEUS during UAE is feasible and may increase the quality of UAE

  17. An ultrasound study of Canadian French rhotic vowels with polar smoothing spline comparisons.

    Science.gov (United States)

    Mielke, Jeff

    2015-05-01

    This is an acoustic and articulatory study of Canadian French rhotic vowels, i.e., mid front rounded vowels /ø œ̃ œ/ produced with a rhotic perceptual quality, much like English [ɚ] or [ɹ], leading heureux, commun, and docteur to sound like [ɚʁɚ], [kɔmɚ̃], and [dɔktaɹʁ]. Ultrasound, video, and acoustic data from 23 Canadian French speakers are analyzed using several measures of mid-sagittal tongue contours, showing that the low F3 of rhotic vowels is achieved using bunched and retroflex tongue postures and that the articulatory-acoustic mapping of F1 and F2 are rearranged in systems with rhotic vowels. A subset of speakers' French vowels are compared with their English [ɹ]/[ɚ], revealing that the French vowels are consistently less extreme in low F3 and its articulatory correlates, even for the most rhotic speakers. Polar coordinates are proposed as a replacement for Cartesian coordinates in calculating smoothing spline comparisons of mid-sagittal tongue shapes, because they enable comparisons to be roughly perpendicular to the tongue surface, which is critical for comparisons involving tongue root position but appropriate for all comparisons involving mid-sagittal tongue contours.

  18. Identification of occult breast lesions detected by magnetic resonance imaging with targeted ultrasound: A prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Aracava, Márcia M., E-mail: marcia.aracava@gmail.com; Chojniak, Rubens, E-mail: chojniak@uol.com.br; Souza, Juliana A., E-mail: julianaalves79@hotmail.com; Bitencourt, Almir G.V., E-mail: almirgvb@yahoo.com.br; Marques, Elvira F., E-mail: elvira.marques@ig.com.br

    2014-03-15

    Objective: To verify the capacity of targeted ultrasound (US) to identify additional lesions detected on breast magnetic resonance imaging (MRI), but occult to initial mammography, US and clinical examinations. Methods: This prospective study included 68 additional relevant breast lesions identified on MRI of 49 patients. As an inclusion criterion, breast US and mammography were required and performed up to six months before MRI. These lesions were then subjected to targeted “second-look” US up to 2 weeks after MRI, performed by one or two radiologists with expertise on breast imaging. Lesions were evaluated according to the established Breast Imaging Report and Data System (BI-RADS) lexicon. Results: Targeted US identified 46/68 (67.6%) lesions revealed by MRI. No significant associations were observed between US identification and the type of lesion, dimensions, morphological characteristics and enhancement pattern according to MRI findings. Targeted US identified 100% of BI-RADS category 5 lesions, 90% of category 4 lesions, and just over 50% of category 3 lesions (p < 0.05). There was significant agreement (p < 0.001) between MRI and US BI-RADS classification for all three categories. Conclusion: Targeted US can identify a large proportion of the lesions detected by breast MRI, especially those at high risk of malignancy, when performed by a professional with experience in both breast US and MRI.

  19. A prospective study of computed tomography, ultrasound, and gallium imaging in patients with fever

    International Nuclear Information System (INIS)

    McNeil, B.J.; Sanders, R.; Alderson, P.O.; Hessel, S.J.; Finberg, H.; Siegelman, S.S.; Adams, D.F.; Abrams, H.L.

    1981-01-01

    Computed tomography, ultrasound, and 67 Ga-citrate imaging were analyzed prospectively in patients thought to have a focal source of sepsis. They were divided into three groups: (a) postoperative, fever greater than or equal to 38.3 degrees C; (b) fever greater than or equal to 38.3 degrees C for less than four weeks, unrelated to surgery; and (c) any fever present for more than four weeks. ROC curves showed no significant difference in the ability of the three modalities to differentiate focal from nonfocal sources of sepsis. If any two examinations were used and either study was abnormal, the sensitivity increased from about 60% to nearly 90% while the false-positive rate increased from about 15% to 25%. When focal disease was diagnosed only if two examinations were abnormal, the false-positive ratio dropped to nearly zero but the sensitivity fell to below 40%. The authors concluded tha all three modalities have a similar ability to detect sepsis and that sensitivity can be increased by using any two of them

  20. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  3. Transvaginal ultrasound

    Science.gov (United States)

    ... bleeding and menstrual problems Certain types of infertility Ectopic pregnancy Pelvic pain Transvaginal ultrasound is also used during ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's ( ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is enlarged. Ultrasound ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... by a computer, which in turn creates a real-time picture on the monitor. One or more ...

  12. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...