WorldWideScience

Sample records for intravascular ultrasound measurements

  1. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...

  2. Harmonic Intravascular Ultrasound

    NARCIS (Netherlands)

    M.E. Frijlink (Martijn)

    2006-01-01

    textabstractMedical ultrasound is a popular imaging modality in cardiology. Harmonic Imaging is a technique that has been shown to increase the image quality of diagnostic ultrasound at frequencies below 10 MHz. However, Intravascular Ultrasound, which is a technique to acoustically investigate

  3. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  4. Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented

    DEFF Research Database (Denmark)

    Huisman, Jennifer; Egede, Rasmus; Rdzanek, Adam

    2012-01-01

    To assess in a multicenter design the between-center reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in coronary lesions that were consecutively stented. To evaluate the reproducibility...

  5. Mapping Intravascular Ultrasound Controversies in Interventional Cardiology Practice

    NARCIS (Netherlands)

    Maresca, D.; Adams, S.; Maresca, B.; Van der Steen, A.F.W.

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  6. Mapping intravascular ultrasound controversies in interventional cardiology practice

    NARCIS (Netherlands)

    Maresca, David; Adams, Samantha; Maresca, Bruno; van der Steen, Antonius F W

    2014-01-01

    Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound

  7. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-06-01

    We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures.

  8. Intravascular Ultrasound and its Use in Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Klepanec, A.; Vulev, I.; Vozar, M.; Balazs, T.; Madaric, J.; Holoman, M.

    2009-01-01

    Intravascular ultrasound has become in invasive vascular radiology in the last decade the important part of diagnostic and also therapeutic procedures in management of vascular diseases. The basic possibilities for the use of IVUS include diagnostic procedures in vascular pathology assessment and therapeutic indications in the field of peripheral vascular interventions (PVI). Unlike other image modalities (CT, MRI, ultrasound) IVUS enables gather unique image in r eal time r ight from the vessel lumen, what helps to add important information regarding vessel wall, plate morphology, thrombi and cross-sectional vessel area. After initial use of intravascular ultrasound in coronary circulation, using IVUS is nowadays widely extended especially in aortic diseases, carotid and renal arteries and arteries of the lower extremities. This review article summarizes possibilities of intravascular ultrasound utilization in diagnostic process and therapy from peripheral vascular diseases up to thoracoabdominal aorta diseases and our experience with this new diagnostic modality. (author)

  9. Discrimination of intravascular lumen and dissections in single intravascular ultrasound images using subtraction, conventional averaging and saline flush

    NARCIS (Netherlands)

    G. Pasterkamp (Gerard); M.S. van der Heiden (M.); M.J. Post (Mark); C. Borst (Cornelius); E.J. Gussenhoven (Elma); H. Pieterman; H. van Urk (Hero); N. Bom (Klaas)

    1995-01-01

    textabstractWith current 30-MHz intravascular ultrasound systems, flowing blood may cause considerable backscatter which in real-time images is characterized by dynamic speckle. However, in a single intravascular ultrasound image (still-frame) the discrimination between arterial lumen and wall may

  10. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  11. An Axial Array for Volumetric Intravascular Ultrasound Imaging

    NARCIS (Netherlands)

    Alles, E.J.

    2012-01-01

    Intravascular ultrasound (IVUS) is a medical imaging modality aimed at imaging blood vessel walls from within the vessel. Current commercial IVUS catheters are designed to yield two-dimensional cross-sectional images perpendicular to the vessel wall. By pulling the catheter back through the artery

  12. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    Science.gov (United States)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  13. Front-end IC design for intravascular ultrasound imaging

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel; Cenkeramaddi, Linga Reddy; Bozkurt, Ayhan

    2008-01-01

    Capacitive micromachined ultrasonic transducers(cMUT) technology is a new trend for intravascular ultrasound (IVUS) imaging. Large bandwidth, high sensitivity and compatibility to CMOS processes makes the cMUT a better choice compared to the conventional piezoelectric transducer. To exploit the merits of cMUT technology, an accurately designed front end circuit is required. The circuit functions as an output pulse driver for the generation of the acoustic signal and buffers the return echo. F...

  14. The clinical importance and prediction of steal following femoro-femoral cross-over bypass: study of the donor iliac artery by intravascular ultrasound, arteriography, duplex scanning and pressure measurements

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, J G; Schroeder, T V

    2000-01-01

    to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal.......to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal....

  15. Recurring extracranial internal carotid artery vasospasm detected by intravascular ultrasound.

    Science.gov (United States)

    Dembo, Tomohisa; Tanahashi, Norio

    2012-01-01

    A 24-year-old woman presented with headache and left-sided focal signs following multiple episodes of right monocular visual impairment. Magnetic resonance angiography revealed a decreased vascular image intensity due to a suspicious stenosis in the right internal carotid artery (ICA). The stenosis was not demonstrated on duplex sonography as it was beyond the field of view of the investigation. Intravascular ultrasound (IVUS) revealed that the outer vessel diameter was significantly reduced during stenosis, supporting the presence of vasospasm. Idiopathic recurrent extracranial ICA vasospasm was diagnosed. Recurrent vasospasms of extracranial ICA may be a distinct entity that can cause ischemic stroke.

  16. Association of insulin resistance and coronary artery remodeling: an intravascular ultrasound study

    OpenAIRE

    Kim, Sang-Hoon; Moon, Jae-Youn; Lim, Yeong Min; Kim, Kyung Ho; Yang, Woo-In; Sung, Jung-Hoon; Yoo, Seung Min; Kim, In Jai; Lim, Sang-Wook; Cha, Dong-Hun; Cho, Seung-Yun

    2015-01-01

    Background There are few studies that investigated the correlation between insulin resistance (IR) and the coronary artery remodeling. The aim of the study is to investigate the association of IR measured by homeostasis model assessment of insulin resistance (HOMA-IR) and coronary artery remodeling evaluated by intravascular ultrasound (IVUS). Methods A total of 298 consecutive patients who received percutaneous coronary interventions under IVUS guidance were retrospectively enrolled. The val...

  17. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...

  18. Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease.

    Science.gov (United States)

    De Maria, Giovanni Luigi; Banning, Adrian P

    2017-05-01

    Due to its potential prognostic implications and technical complexity, revascularisation of left main coronary artery (LMCA) disease requires careful consideration. Since publication of the results of the SYNTAX study, and more recently the EXCEL and NOBLE trials, there has been particular interest in percutaneous revascularisation of the LMCA. It is becoming clear that percutaneous revascularisation of LMCA disease requires appropriate lesion preparation and carefully optimised stenting in order to offer patients a treatment option as effective as coronary artery bypass grafting. For this reason intravascular imaging, and especially intravascular ultrasound, is becoming a key procedural step in LMCA percutaneous coronary intervention. In the current review paper we analyse the role of intravascular imaging with intravascular ultrasound in LMCA percutaneous coronary intervention, focusing on the main applications in this context from lesion assessment to stent sizing and optimisation.

  19. Monolithic CMUT on CMOS Integration for Intravascular Ultrasound Applications

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F. Levent

    2012-01-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter based volumetric imaging arrays where the elements need to be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom designed CMOS receiver electronics from a commercial IC foundry. The CMUT on CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT to CMOS interconnection. This CMUT to CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire bonding method. Characterization experiments indicate that the CMUT on CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Experiments on a 1.6 mm diameter dual-ring CMUT array with a 15 MHz center frequency show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging CTOs located 1 cm away from the CMUT array. PMID:23443701

  20. Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications.

    Science.gov (United States)

    Zahorian, Jaime; Hochman, Michael; Xu, Toby; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Degertekin, F Levent

    2011-12-01

    One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Ex- periments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.

  1. Relationship between intravascular ultrasound parameters and fractional flow reserve in intermediate coronary artery stenosis of left anterior descending artery: intravascular ultrasound volumetric analysis.

    Science.gov (United States)

    Yang, Hyoung-Mo; Tahk, Seung-Jea; Lim, Hong-Seok; Yoon, Myeong-Ho; Choi, So-Yeon; Choi, Byoung-Joo; Jin, Xiong Jie; Hwang, Gyo-Seung; Park, Jin-Sun; Shin, Joon-Han

    2014-02-15

    The objective of this study was to assess the relationship between intravascular ultrasound (IVUS) parameters, including volumetric analysis, and fractional flow reserve (FFR). Although it is known that coronary atherosclerosis burden measured by IVUS volumetric analysis is related with clinical outcomes, its relationship with functional significance remains unknown. Both IVUS and FFR were performed in 206 cases of intermediate stenosis of the left anterior descending artery (LAD). Myocardial ischemia was assessed by FFR and maximal hyperemia was induced by continuous intracoronary adenosine infusion. FFR  0.80 were associated with larger plaque volume (181.8 ± 82.3 vs. 125.9 ± 77.9 mm3, P < 0.001) and PAV (58.9 ± 5.6 vs. 53.8 ± 7.9%, P < 0.001). IVUS parameters representing severity and extent of atheromatous plaque correlated with functional significance in LAD lesions with intermediate stenosis.

  2. Design of low noise transimpedance amplifier for intravascular ultrasound

    KAUST Repository

    Reda, Dina

    2009-11-01

    In this paper, we study transimpedance amplifiers for capacitive sensing applications with a focus on Intravascular Ultra Sound (IVUS). We employ RF noise cancellation technique on capacitive feedback based transimpedance amplifiers. This technique eliminates the input-referred noise of TIAs completely and enhances the dynamic range of front-end electronics. Simulation results verify the proposed technique used in two different TIA topologies employing shunt-shunt feedback. ©2009 IEEE.

  3. Low variation and high reproducibility in plaque volume with intravascular ultrasound

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik

    2004-01-01

    BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied by electrocardiog......BACKGROUND: Intravascular ultrasound (IVUS) has several advantages compared to angiography when evaluating coronary atherosclerosis in the vessel wall. METHODS: The accuracy, reproducibility, and short-time spontaneous variation in volume of vessel, plaque and lumen were studied...... by electrocardiographic-gated three-dimensional (3D) IVUS in 20 male patients with ischaemic heart disease (IHD). RESULTS: The study lesions were angiographically insignificant, with a length of the analysed segment on 11.4+/-5.9 mm. At baseline the mean minimal lumen diameter was 2.41+/-0.59 mm, minimal lumen area 4......=0.804; pIVUS is a highly reproducible method when applied on coronary artery...

  4. Serial intravascular ultrasound assessment of changes in coronary atherosclerotic plaque dimensions and composition: an update

    DEFF Research Database (Denmark)

    Hartmann, Marc; Huisman, Jennifer; Böse, Dirk

    2011-01-01

    This manuscript reviews the use of serial intravascular ultrasound (IVUS) examination of coronary atherosclerosis in recent observational studies and randomized trials that revealed the effects of cholesterol-lowering and lipid-modifying therapies and offered novel insight into plaque progression....... Finally, we report on the evaluation of true vessel remodelling in recent serial IVUS trials and discuss the future perspective of serial invasive imaging of coronary atherosclerosis....

  5. Multimodality Intracoronary Imaging With Near-Infrared Spectroscopy and Intravascular Ultrasound in Asymptomatic Individuals With High Calcium Scores.

    Science.gov (United States)

    Madder, Ryan D; VanOosterhout, Stacie; Klungle, David; Mulder, Abbey; Elmore, Matthew; Decker, Jeffrey M; Langholz, David; Boyden, Thomas F; Parker, Jessica; Muller, James E

    2017-10-01

    This study sought to determine the frequency of large lipid-rich plaques (LRP) in the coronary arteries of individuals with high coronary artery calcium scores (CACS) and to determine whether the CACS correlates with coronary lipid burden. Combined near-infrared spectroscopy and intravascular ultrasound was performed in 57 vessels in 20 asymptomatic individuals (90% on statins) with no prior history of coronary artery disease who had a screening CACS ≥300 Agatston units. Among 268 10-mm coronary segments, near-infrared spectroscopy images were analyzed for LRP, defined as a bright yellow block on the near-infrared spectroscopy block chemogram. Lipid burden was assessed as the lipid core burden index (LCBI), and large LRP were defined as a maximum LCBI in 4 mm ≥400. Vessel plaque volume was measured by quantitative intravascular ultrasound. Vessel-level CACS significantly correlated with plaque volume by intravascular ultrasound ( r =0.69; P infrared spectroscopy ( r =0.24; P =0.07). Despite a high CACS, no LRP was detected in 8 (40.0%) subjects. Large LRP having a maximum LCBI in 4 mm ≥400 were infrequent, found in only 5 (25.0%) of 20 subjects and in only 5 (1.9%) of 268 10-mm coronary segments analyzed. Among individuals with a CACS ≥300 Agatston units mostly on statins, CACS correlated with total plaque volume but not LCBI. This observation may have implications on coronary risk among individuals with a high CACS considering that it is coronary LRP, rather than calcification, that underlies the majority of acute coronary events. © 2017 American Heart Association, Inc.

  6. Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

    Science.gov (United States)

    Yoon, Sangpil; Williams, Jay; Kang, Bong Jin; Yoon, Changhan; Cabrera-Munoz, Nestor; Jeong, Jong Seob; Lee, Sang Goo; Shung, K Kirk; Kim, Hyung Ham

    2015-06-01

    A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast.

  7. Intravascular ultrasound assessment of remodelling and reference segment plaque burden in type-2 diabetic patients

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2007-01-01

    AIMS: Intravascular ultrasound (IVUS) assesses arterial remodelling by comparing the lesion external elastic membrane (EEM) with the reference segments; however, reference segments are rarely disease-free. The aim was to assess lesion and reference segment remodelling and plaque burden in patients...... with type-2 diabetes mellitus. METHODS AND RESULTS: We used pre-intervention IVUS to study 62 de novo lesions in 43 patients with type-2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal...... IVUS lumen and quantitative coronary angiographic artery...

  8. Successful Intravascular Ultrasound-Guided Transradial Coronary Intervention with a 4Fr Guiding Catheter.

    Science.gov (United States)

    Nakano, Yasuhiro; Sadamatsu, Kenji

    2016-01-01

    Minimizing the catheter size can reduce vascular access complications and contrast dye usage in coronary angiography. The small diameter of the 4Fr guiding catheter has limited the use of several angioplasty devices such as intravascular ultrasound (IVUS) in the past. However, the combination of a novel IVUS catheter and a 0.010 guidewire makes it possible to perform IVUS-guided percutaneous coronary intervention (PCI) with a 4Fr guiding catheter. We herein report the case of a 51-year-old man with silent myocardial ischemia who underwent IVUS-guided transradial PCI with a 4Fr guiding catheter.

  9. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  10. Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

    Science.gov (United States)

    Tardif, J C; Bertrand, O F; Mongrain, R; Lespérance, J; Grégoire, J; Paiement, P; Bonan, R

    2000-10-01

    Both mechanical and multi-element intravascular ultrasound designs have potential advantages and limitations that may impact on their value for clinical and research purposes. Determination of the reproducibility of measurements is critical before a given system can be used in studies such as regression of atherosclerosis trials. We performed serial intravascular ultrasound imaging with catheters using mechanical and phased-array designs in stented and non-stented coronary arteries in dogs and in patients. Both systems correlated well for areas (r > or = 0.90, p or = 0.84. p mechanical designs for measurements of area (mean difference in dogs and in patients: -0.24 and 0.96 mm2, p mechanical system (r > or = 0.96 for all measurements). The differences in absolute and relative variability between the mechanical and phased-array designs, both for reanalysis of same frames and serial pullbacks, were very small. Although multi-element and mechanical intravascular ultrasound designs are not strictly interchangeable, their similar reproducibility and the small differences in measurements demonstrate that both designs are acceptable alternatives for trials of regression of atherosclerosis. Determination of the variability for serial pullbacks of both designs was also important to assess the statistical power of such trials.

  11. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  12. 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

    Science.gov (United States)

    Yeh, David T; Oralkan, Omer; Wygant, Ira O; O'Donnell, Matthew; Khuri-Yakub, Butrus T

    2006-06-01

    Forward-viewing ring arrays can enable new applications in intravascular and intracardiac ultrasound. This work presents compelling, full-synthetic, phased-array volumetric images from a forward-viewing capacitive micromachined ultrasonic transducer (CMUT) ring array wire bonded to a custom integrated circuit front end. The CMUT ring array has a diameter of 2 mm and 64 elements each 100 microm x 100 microm in size. In conventional mode, echo signals received from a plane reflector at 5 mm had 70% fractional bandwidth around a center frequency of 8.3 MHz. In collapse mode, 69% fractional bandwidth is measured around 19 MHz. Measured signal-to-noise ratio (SNR) of the echo averaged 16 times was 29 dB for conventional operation and 35 dB for collapse mode. B-scans were generated of a target consisting of steel wires 0.3 mm in diameter to determine resolution performance. The 6 dB axial and lateral resolutions for the B-scan of the wire target are 189 microm and 0.112 radians for 8 MHz, and 78 microm and 0.051 radians for 19 MHz. A reduced firing set suitable for real-time, intravascular applications was generated and shown to produce acceptable images. Rendered three-dimensional (3-D) images of a Palmaz-Schatz stent also are shown, demonstrating that the imaging quality is sufficient for practical applications.

  13. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    Introduction: Drug-eluting stents (DES) reduce the risk of restenosis after percutaneous coronary intervention. The aim of the study was to evaluate, by intravascular ultrasound (IVUS), the minimum lumen area site in the stented segment and the distribution of intimal hyperplasia in patients...

  14. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...... diameter was 1.56 +/- 0.55 mm. The mean difference between the IVUS reference lumen diameter and angiographic reference lumen diameter was 0.18 +/- 0.44 mm. Plaque burden in the reference segment correlated inversely with the difference between IVUS and quantitative coronary angiographic reference lumen...

  15. Characterization of a saphenous vein graft aneurysm by intravascular ultrasound and computerized three-dimensional reconstruction.

    Science.gov (United States)

    Ennis, B M; Zientek, D M; Ruggie, N T; Billhardt, R A; Klein, L W

    1993-04-01

    Aneurysmal dilatations in saphenous vein grafts are rare complications of coronary artery bypass surgery that mostly represent thin-wall pseudoaneurysms at anastomotic sites. We describe a case of an enlarging distal saphenous vein graft aneurysm in which intravascular ultrasound (IVUS) and computerized three-dimensional reconstruction (3DR) of the IVUS images was performed to conclusively demonstrate true aneurysm morphology. Although both atherosclerotic and nonatherosclerotic mechanisms for vein graft aneurysm formation have been previously suggested, IVUS images and 3DR of the aneurysm in this case did not reveal any of the features typical for atherosclerotic lesions. Further, the IVUS images and 3DR suggest that progressive atherosclerosis is not the likely cause of aneurysm formation in this case. This application of IVUS and 3DR provides detailed information about saphenous vein graft aneurysm structure, clues to aneurysm formation, and suggests a natural history that may differ from that of pseudoaneurysms.

  16. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    Two morphological methods for quantifying the degree of stenoses in the iliac arteries, intravascular ultrasound (IVUS) and arteriography, were compared with duplex scanning, a method of evaluating the haemodynamic importance of the stenosis. A total of 38 patients, 20 women and 18 men, median age...... 66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...

  17. The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy

    DEFF Research Database (Denmark)

    Vogt, K C; Sillesen, H; Schroeder, T V

    1998-01-01

    To evaluate the application of intravascular ultrasound (IVUS) for intraoperative assessment of semiclosed thromboendarterectomy (TEA), IVUS images of the iliofemoral segment in 20 patients were obtained. The configuration and size of residual atherosclerotic material were evaluated. Stenoses...... was detected in the artery by IVUS. The material was removed in five cases. The part of the iliac artery proximal to the endarterectomized segment was visualized in 14 cases and showed minor stenoses in 10 cases. After follow-up at a median of 8 months (range 1-24), occlusion had occurred in one of 20 patients...... and restenosis (> 50%) had developed in two (10%). At this point, patency cannot be related to IVUS findings. We conclude that IVUS is a feasible method for intraoperative assessment of semiclosed TEA. The rate of early failures due to residual material might be reduced by this new application of IVUS....

  18. The role of Intravascular Ultrasound in the management of spontaneous coronary artery dissection

    Directory of Open Access Journals (Sweden)

    Karamitsos Theodoros D

    2008-05-01

    Full Text Available Abstract Primary or spontaneous coronary artery dissection (SCAD is an unusual but increasingly recognized cause of acute myocardial ischemia and sudden cardiac death. Typically, SCAD presents in younger patients without conventional risk factors for coronary artery disease. It occurs more commonly in women than in men, and frequently during pregnancy or the postpartum period. Its pathophysiology is poorly understood, and there is considerable controversy regarding the optimal management of patients with SCAD-related myocardial ischemia. Therapeutic approaches include conservative medical therapy, coronary artery bypass graft surgery and percutaneous coronary intervention (PCI. We present four cases of SCAD to illustrate specific aspects of the presentation and management of this condition, with particular reference to the importance of intravascular ultrasound (IVUS to aid diagnosis and guide subsequent PCI.

  19. Comparison of angiography and intravascular ultrasound before and after balloon angioplasty of the femoropopliteal artery

    International Nuclear Information System (INIS)

    Lankeren, Winnifred van; Gussenhoven, Elma J.; Pieterman, Herman; Sambeek, Marc R. H. M. van; Lugt, Aad van der

    1998-01-01

    Purpose: To compare angiographic and intravascular ultrasound (IVUS) data before and after balloon angioplasty (PTA) of the femoropopliteal artery.Methods: Qualitative and quantitative analyses were performed on corresponding angiographic and IVUS levels obtained from 135 patients.Results: IVUS detected more lesions, calcified lesions, and vascular damage than angiography. Sensitivity of angiography was good for the presence of a lesion (84%), moderate for eccentric lesions (53%) and for vascular damage (52%), and poor for calcified lesions (30%). The increase in angiographic diameter stenosis was associated with a decrease in lumen area and increase in percentage area stenosis on IVUS.Conclusions: Angiography is less sensitive than IVUS for detecting lesion eccentricity, calcified lesions, and vascular damage. Presence of a lesion and amount of plaque were underestimated angiographically. Only before PTA was good agreement found between angiographic diameter stenosis and lumen size on IVUS.

  20. Perspectives on Imaging the Left Main Coronary Artery Using Intravascular Ultrasound and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Harry C Lowe

    2015-01-01

    Full Text Available Percutaneous Coronary Intervention (PCI for significant left main coronary artery (LMCA stenosis is increasingly being viewed as a viable alternative to Coronary Artery Bypass Grafting (CABG (1. This is leading to an expectation of increasing numbers of such procedures, with a consequent focus on both the ability to image both lesion severity, and assess more accurately the results of PCI. While there have been advances in physiologic assessment of left main severity using fractional flow reserve (FFR, imaging of the LMCA using Intravascular Ultrasound (IVUS and more recently Optical Coherence Tomography (OCT has the specific advantage of being able to provide detailed anatomical information both pre and post PCI, such that it is timely to review briefly the current status of these two imaging technologies in the context of LMCA intervention.

  1. The Imaging Modulography Technique Revisited for High-Definition Intravascular Ultrasound: Theoretical Framework.

    Science.gov (United States)

    Tacheau, Antoine; Le Floc'h, Simon; Finet, Gérard; Doyley, Marvin M; Pettigrew, Roderic I; Cloutier, Guy; Ohayon, Jacques

    2016-03-01

    Mechanical characterization of atherosclerotic lesions remains an essential step for the detection of vulnerable plaques (VPs). Recently, an intravascular ultrasound (IVUS) elasticity reconstruction method (iMOD) has been tested in vivo by our group. The major limitation of iMOD is the need to estimate the strain field in the entire VP despite attenuated depth penetration signals when using high-definition (HD) IVUS systems. Therefore, an extended iMOD approach (E-iMOD) was designed and applied to coronary lesions of patients imaged in vivo with IVUS. The E-iMOD method (i) quantified necrotic core areas with a mean absolute relative error of 3.5 ± 3.5% and (ii) identified Young's moduli of the necrotic cores and fibrous regions with mean values of 5.7 ± 0.8 kPa and 794.5 ± 22.0 kPa instead of 5 kPa and 800 kPa, respectively. This study demonstrates the potential of the improved HD-IVUS modulography technique E-iMOD to characterize coronary VPs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  2. Resolution of spontaneous coronary artery dissection within 3 weeks detected by computed tomography angiography and intravascular ultrasound.

    Science.gov (United States)

    Tsutsui, Hiroshi; Chino, Chiharu; Komatsu, Miho; Sakai, Takahiro; Aizawa, Kazunori; Owa, Mafumi

    2017-01-01

    A 62-year-old woman was admitted with chest pain lasting about 3 h. Spontaneous coronary artery dissection (SCAD) was detected in the left anterior descending artery (LAD) by intravascular ultrasound (IVUS). Sixteen days after onset, follow-up computed tomography angiography was performed and revealed shrinkage of the false lumen of the SCAD. On hospital day 22, IVUS image confirmed that the SCAD in the LAD was completely healed. This case shows the possibility of rapid healing of SCAD.

  3. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  4. Expansion in calcific lesions and overall clinical outcomes following bioresorbable scaffold implantation optimized with intravascular ultrasound.

    Science.gov (United States)

    Kawamoto, Hiroyoshi; Ruparelia, Neil; Latib, Azeem; Miyazaki, Tadashi; Sato, Katsumasa; Tanaka, Akihito; Naganuma, Toru; Sticchi, Alessandro; Chieffo, Alaide; Carlino, Mauro; Montorfano, Matteo; Colombo, Antonio

    2017-04-01

    This study aimed to investigate clinical outcomes following bioresorbable scaffold (BRS) optimized with intravascular ultrasound (IVUS), and furthermore expansion of BRS in calcific lesions. Although IVUS use has contributed to improved clinical outcomes with metallic stent implantation, it is unclear if this is also true with regards to BRS, especially in calcified lesions. Between May 2012 and April 2015, 291 lesions in 198 patients were treated with BRS with IVUS use. We evaluated overall clinical outcomes at 1-year and investigated the expansion and eccentricity index of BRS amongst quadrants categorized by calcium arc (CA) every 90-degrees. The rates of major adverse cardiac events were 5.4% (at 6 months) and 10.7% (at 12 months). TLR was observed in 3.1% at 6-month and 7.5% at 12-month follow up. Although there was a significant difference among quadrants regarding to eccentricity of calcium (0°≦CA BRS expansion index [minimal scaffold area (MSA) divided by BRS area expanded at a nominal pressure] was comparable between quadrants. The use of IVUS to optimize BRS implantation results in favorable clinical outcomes even for complex lesions. Although eccentric calcium distribution resulted in asymmetric expansion of BRS, the final MSA was comparable irrespective of calcium distribution. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Determinants of slow flow following stent implantation in intravascular ultrasound-guided primary percutaneous coronary intervention.

    Science.gov (United States)

    Watanabe, Yusuke; Sakakura, Kenichi; Taniguchi, Yousuke; Yamamoto, Kei; Wada, Hiroshi; Fujita, Hideo; Momomura, Shin-Ichi

    2018-03-01

    Slow flow is a serious complication in primary percutaneous coronary intervention (PCI) and is associated with poor clinical outcomes. Intravascular ultrasound (IVUS)-guided PCI may improve clinical outcomes after drug-eluting stent implantation. The purpose of this study was to seek the factors of slow flow following stent implantation, including factors related to IVUS-guided primary PCI. The study population consisted of 339 ST-elevation myocardial infarction patients, who underwent stent deployment with IVUS. During PCI, 56 patients (16.5%) had transient or permanent slow flow. Multivariate logistic regression analysis showed age (OR 1.04, 95% CI 1.01-1.07, P = 0.01), low attenuation plaque on IVUS (OR 3.38, 95% CI 1.70-6.72, P = 0.001), initial Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 (vs. TIMI 0: OR 0.44, 95% CI 0.20-0.99, P = 0.046), and the ratio of stent diameter to vessel diameter (per 0.1 increase: OR 2.63, 95% CI 1.84-3.77, P flow. A ratio of stent diameter to vessel diameter of 0.71 had an 80.4% sensitivity and 56.9% specificity to predict slow flow. There was no significant difference in ischemic-driven target vessel revascularization between the modest stent expansion (ratio of stent diameter to vessel diameter flow following stent implantation in IVUS-guided primary PCI.

  6. Visualization of plaque distribution in a curved artery: three-dimensional intravascular ultrasound imaging.

    Science.gov (United States)

    Choi, Ahnryul; McPherson, David D; Kim, Hyunggun

    2017-12-01

    Intravascular ultrasound (IVUS) imaging provides an excellent tool for evaluation of the type, morphology, extent, and severity of an atheromatous plaque. 3 D IVUS imaging offers additive information pertaining to morphology of the arterial structures and volumetric plaque distributions. A new 3 D IVUS visualization technique was developed to provide 3 D structural information of a curved artery. A virtual 3 D curved arterial phantom consisting of varying cross-sectional shapes, wall thicknesses, and acoustic intensity information was utilized to validate the nonlinear interpolation technique to create intermediary 2 D IVUS images. IVUS imaging was performed for the iliofemoral arterial segment of an atherosclerotic Yucatan miniswine model. These in-vivo IVUS data were utilized for intermediary IVUS image generation and volumetric 3 D IVUS visualization. Smooth transitional changes of cross-sectional shape, wall thickness and grayscale intensity were found between the intermediary images and the original arterial phantom slices. The 3 D IVUS imaging of the unfolded curved iliofemoral artery provided realistic 3 D luminal surface images of the arteries with physiologic grayscale intensity information. This unique 3 D IVUS imaging technique may help with assessment of 3 D plaque distribution across the curved arterial structure, and improve 3 D visualization of atheromatous components.

  7. Clinical feasibility of 3D automated coronary atherosclerotic plaque quantification algorithm on coronary computed tomography angiography: Comparison with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung-Bok [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Myongji Hospital, Division of Cardiology, Cardiovascular Center, Goyang (Korea, Republic of); Lee, Byoung Kwon [Yonsei University College of Medicine, Division of Cardiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Shin, Sanghoon [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); National Health Insurance Corporation Ilsan Hospital, Division of Cardiology, Goyang (Korea, Republic of); Heo, Ran; Chang, Hyuk-Jae; Chung, Namsik [Yonsei University Health System, Yonsei-Cedar Sinai Integrative Cardiovascular Imaging Research Center, Seoul (Korea, Republic of); Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of); Arsanjani, Reza [Cedars-Sinai Medical Center, Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Los Angeles, CA (United States); Kitslaar, Pieter H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical Imaging Systems B.V., Leiden (Netherlands); Broersen, Alexander; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Ahn, Sung Gyun [Yonsei University Wonju Severance Christian Hospital, Division of Cardiology, Wonju (Korea, Republic of); Min, James K. [New York-Presbyterian Hospital, Institute for Cardiovascular Imaging, Weill-Cornell Medical College, New York, NY (United States); Hong, Myeong-Ki; Jang, Yangsoo [Yonsei University Health System, Division of Cardiology, Severance Cardiovascular Hospital, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS) were analyzed. Minimal lumen area (MLA), maximal lumen area stenosis percentage (%AS), mean plaque burden percentage (%PB), and plaque volume were measured semi-automatically by expert, non-expert, and fully automatic QCT analyses, and then compared to IVUS. Between IVUS and expert QCT analysis, the correlation coefficients (r) for the MLA, %AS, %PB, and plaque volume were excellent: 0.89 (p < 0.001), 0.84 (p < 0.001), 0.91 (p < 0.001), and 0.94 (p < 0.001), respectively. There were no significant differences in the mean parameters (all p values >0.05) except %AS (p = 0.01). The automatic QCT analysis showed comparable performance to non-expert QCT analysis, showing correlation coefficients (r) of the MLA (0.80 vs. 0.82), %AS (0.82 vs. 0.80), %PB (0.84 vs. 0.73), and plaque volume (0.84 vs. 0.79) when they were compared to IVUS, respectively. Fully automatic QCT analysis showed clinical utility compared with IVUS, as well as a compelling performance when compared with semiautomatic analyses. (orig.)

  8. Monitoring of allograft vasculopathy by intravascular ultrasound one month and one year after heart transplantation: A single center study.

    Science.gov (United States)

    Bedanova, Helena; Orban, Marek; Tretina, Martin; Fila, Petr; Horvath, Vladimir; Krejci, Jan; Nemec, Petr

    2016-03-01

    The aim of this trial was to use intravascular ultrasound (IVUS) to determine whether cardiac allograft vasculopathy (CAV) starts progressing during the first year after heart transplantation (HTx). We retrospectively analyzed 51 patients (11 women) who received heart transplants in our center between January 2010 and September 2013 and underwent coronary angiography as well as IVUS examination one month and one year after HTx. Patients with proven calcification and fibrotic plates in the IVUS examination one month after HTx constituted a group with defined donor-transmitted atherosclerosis (DTA). In patients without DTA, measurements of maximal intimal thickening (MIT) were made in two predetermined locations. Eight of the 51 patients had DTA, while 43 did not. These were divided based on maximal intimal thickness (MIT) into a group with MIT first year after HTx significantly more frequently in patients with DTA and MIT ≥ 0.5 mm. It is essential in these patients to implement an IVUS control examination one year after transplantation. The results can lead to a change in treatment strategy to prevent further progress of the disease.

  9. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  10. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  11. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    International Nuclear Information System (INIS)

    Figueiredo, José Albuquerque Neto de; Nogueira, Iara Antonia Lustosa; Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio

    2013-01-01

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I 2 test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I 2 = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I 2 = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I 2 = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I 2 = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes

  12. Correlation between dual-axis rotational coronary angiography and intravascular ultrasound in a coronary lesion assessment.

    Science.gov (United States)

    Jin, Zhi-Geng; Zhang, Zhuo-Qi; Jing, Li-Min; Wei, Yu-Jie; Zhang, Jiao; Luo, Jian-Ping; Yang, Sheng-Li; Ma, Dong-Xing; Liu, Ying; Han, Wei; Yang, Yong; Liu, Hui-Liang

    2017-02-01

    The purpose of this study was to evaluate the accuracy of dual-axis rotational coronary angiography (DARCA) for coronary lesion assessment by directly comparing with intravascular ultrasound (IVUS). From October 2014 to December 2015, 40 patients (58 lesions) who had undergone both DARCA and IVUS were included in the image analysis. The minimum lumen diameter (MLD), lesion length, reference vessel diameter (RVD) and percent diameter stenosis at the same lesion, were identified and assessed. Significant correlation with IVUS was found for DARCA in either lesion length (r = 0.90, P < 0.001) or RVD (r = 0.81, P < 0.001) comparison. DARCA had fair correlation with IVUS for both MLD (r = 0.65, P < 0.001) and diameter stenosis (r = 0.48, P < 0.001). From the Bland-Altman plots, there was a good agreement between DARCA and IVUS regarding MLD (mean difference: -0.23 mm, 95 % limits of agreement: -0.96 to 0.50 mm) and RVD (mean difference: -0.15 mm, 95 % limits of agreement: -0.85 to 0.55 mm), while lesser agreement was found on lesion length (mean difference: -3.39 mm, 95 % limits of agreement: -12.63 to 5.85 mm) and diameter stenosis (mean difference: 4.82 %, 95 % limits of agreement: -17.05 to 26.68 %). There is an adequate correlation and agreement between DARCA and IVUS in coronary lesion assessment.

  13. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  14. Intravascular Ultrasound Catheter Evaluation of the Left Ventricle in Mice: A Feasibility Study.

    Science.gov (United States)

    Gardin, Julius M.; Siri, Francis; Kitsis, Richard N.; Leinwand, Leslie

    1996-11-01

    With the advent of transgenic technology, it has become increasingly important to find a method for evaluating left ventricular (LV) anatomy and function in intact wild type, intervened, and transgenic mice. Mice are 1/10th the size of rats, and have body masses of 10-60 g, LV masses of 40-150 mg, LV wall thicknesses of 0.5-2 mm, and LV internal dimensions of 1-3 mm. Although the murine LV has been imaged by transthoracic (TTE) two-dimensional directed M-mode echocardiography, we explored the use of intravascular ultrasound (IVUS) catheters, with imaging from various positions, to see if better two-dimensional images of the LV could be obtained by IVUS than TTE. Eight normal mice were anesthetized using pentobarbital or avertin. The mice were studied using a commercially available IVUS system (Endosonics, Inc.). Two IVUS catheters (3.5 and 5.0 Fr) with 20-MHz multielement array transducers were used. Each catheter had a 4.0-mm imaging depth of field in all directions (360 degrees ) from the mid-point of the catheter core. Multiple imaging approaches were attempted: transesophageal (TEE); transjugular (TJ); transperitoneal (TP); and open chest, from both epicardial surface (Ep) and via direct LV puncture. TEE and TJ approaches afforded insufficient depth of field to image the entire LV in cross section. TP and Ep approaches resulted in poor images, related both to inadequate depth of field and to relatively small sector angles subtended by imaging elements. LVP (intracavitary imaging) was capable of satisfactorily imaging the LV epicardium, but was unable to image the endocardium, probably because the latter was within the 1.9-mm "ringdown" catheter artifact. All IVUS approach studies lacked sufficient temporal resolution (10 frames/sec) to reliably display systolic and diastolic frames necessary for evaluation of LV function. In contrast, as previously reported, transthoracic two-dimensionally directed M-mode echocardiograms have sufficient temporal and spatial

  15. Natural history of intravascular ultrasound-detected edge dissections from coronary stent deployment.

    Science.gov (United States)

    Sheris, S J; Canos, M R; Weissman, N J

    2000-01-01

    High-resolution intravascular ultrasound (IVUS) performed immediately after stent deployment often reveals dissection at the stent margin that may not be appreciated by angiography. However, the natural history of these edge dissections is unknown. These intimal disruptions at the stent margins have been previously reported to occur in 5% to 23% of stent implantations. The short-term prognosis of these lesions appears to be good; however, the longer-term effect on restenosis and/or vessel remodeling is not known. We therefore studied a cohort of patients with the use of IVUS immediately after stent implantation and at 6 months to assess the incidence and prognosis of coronary edge dissections. One hundred fifty patients undergoing Palmaz-Shatz stent implantation were imaged with IVUS with the use of a motorized pullback, and the incidence of edge dissections was determined and graded according to depth and circumferential extent. Arterial and lesional morphometric parameters were assessed by digital planimetry. Six-month IVUS images were aligned with the poststent IVUS to determine the natural history of these lesions. Sixteen (10.7%) of 150 had edge tears. All were angiographically silent. Most lesions (n = 9) were superficial intimal tears. Vessel, lumen, and plaque area were similar in the nondissection and dissection groups in both the proximal and distal reference segments. Plaque eccentricity was likewise similar in both groups. At 6 months, lesions (n = 12) healed without a change in plaque burden, undergoing a "tacking down" process. Vessel area (19. 1 +/- 6.4 vs 18.4 +/- 7.1 mm(2), P = not significant), lumen area (8. 2 +/- 4.1 vs 9.2 +/- 4.0 mm(2), P = not significant), and plaque area (10.0 +/- 3.3 vs 9.8 +/- 3.3 mm(2), P = not significant) were unchanged when compared with the lesion site taken at stent deployment. Edge dissections as detected by IVUS do not necessarily proscribe an adverse prognosis at 6 months. This finding may provide reassurance to

  16. Segmentation of arterial walls in intravascular ultrasound cross-sectional images using extremal region selection.

    Science.gov (United States)

    Faraji, Mehdi; Cheng, Irene; Naudin, Iris; Basu, Anup

    2018-03-01

    Intravascular Ultrasound (IVUS) is an intra-operative imaging modality that facilitates observing and appraising the vessel wall structure of the human coronary arteries. Segmentation of arterial wall boundaries from the IVUS images is not only crucial for quantitative analysis of the vessel walls and plaque characteristics, but is also necessary for generating 3D reconstructed models of the artery. The aim of this study is twofold. Firstly, we investigate the feasibility of using a recently proposed region detector, namely Extremal Region of Extremum Level (EREL) to delineate the luminal and media-adventitia borders in IVUS frames acquired by 20 MHz probes. Secondly, we propose a region selection strategy to label two ERELs as lumen and media based on the stability of their textural information. We extensively evaluated our selection strategy on the test set of a standard publicly available dataset containing 326 IVUS B-mode images. We showed that in the best case, the average Hausdorff Distances (HD) between the extracted ERELs and the actual lumen and media were 0.22  mm and 0.45 mm, respectively. The results of our experiments revealed that our selection strategy was able to segment the lumen with ⩽0.3 mm HD to the gold standard even though the images contained major artifacts such as bifurcations, shadows, and side branches. Moreover, when there was no artifact, our proposed method was able to delineate media-adventitia boundaries with 0.31 mm HD to the gold standard. Furthermore, our proposed segmentation method runs in time that is linear in the number of pixels in each frame. Based on the results of this work, by using a 20 MHz IVUS probe with controlled pullback, not only can we now analyze the internal structure of human arteries more accurately, but also segment each frame during the pullback procedure because of the low run time of our proposed segmentation method. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Regression and shift in composition of coronary atherosclerotic plaques by pioglitazone: insight from an intravascular ultrasound analysis.

    Science.gov (United States)

    Clementi, Fabrizio; Di Luozzo, Marco; Mango, Ruggiero; Luciani, Giulio; Trivisonno, Antonio; Pizzuto, Francesco; Martuscelli, Eugenio; Mehta, Jawahar L; Romeo, Francesco

    2009-03-01

    Plaque reduction with the use of pioglitazone and statin combination therapy has been observed in carotid plaque. We sought to investigate the effect of combination therapy with statins and pioglitazone on coronary plaque regression and composition with the use of intravascular ultrasound (IVUS) and intravascular ultrasound-virtual histology (IVUS-VH). We analysed 29 plaques in 25 diabetic patients with angiographic evidence of nonsignificant coronary lesions with IVUS-VH. Patients were treated with 80 mg of atorvastatin and 30 mg of pioglitazone daily for 6 months. After 6 months of therapy, IVUS-VH of each lesion was reacquired. Mean elastic external membrane volume was significantly reduced between baseline and follow-up (343.9 vs. 320.5 mm; P < 0.05) as was mean total atheroma volume (179.3 vs. 166.6 mm; P < 0.05). Change in total atheroma volume showed a 6.3% mean reduction. Areas of fibrous tissue, fibrolipidic tissue and calcium decreased over the 6 months of follow-up, although not significantly. On the other hand, the necrotic core increased from 9 to 14% (P < 0.05). Our data demonstrated that atorvastatin/pioglitazone association is able to induce significant regression of coronary atherosclerosis, acting on plaque composition. Our findings are preliminary results and will be confirmed in an ongoing randomized placebo-controlled multicenter trial (PIPER; Pioglitazone for Prevention of Restenosis in Diabetics with Complex Lesion; trial registration: clinical trials.gov. Identifier: NCT 00376870).

  18. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  19. Reproducibility of intravascular ultrasound radiofrequency data analysis (virtual histology) with a 45-MHz rotational imaging catheter in ex vivo human coronary arteries

    NARCIS (Netherlands)

    T. Muramatsu (Takashi); H.M. Garcia-Garcia (Hector); S. Brugaletta (Salvatore); J.H. Heo (Jungho); Y. Onuma (Yoshinobu); R.J. Fedewa (Russell J.); A. Nair (Anuja); Y. Ozaki (Yukio); P.W.J.C. Serruys (Patrick)

    2015-01-01

    textabstractBackground: Despite the frequent use of spectral analysis of intravascular ultrasound radiofrequency data (VH® IVUS) in clinical studies, the assessment for reproducibility using this with high frequency IVUS remains unexplored. Purpose: The aim of this study was to examine the

  20. Cardiac allograft vasculopathy compared by intravascular ultrasound sonography: everolimus to mycophenolate mofetil--one single-center experience.

    Science.gov (United States)

    Chou, N-K; Jan, C-F; Chi, N-H; Lee, C-M; Wu, I-H; Huang, S-C; Chen, Y-S; Yu, H-Y; Tsao, C-I; Ko, W-J; Chu, S-H; Wang, S-S

    2012-05-01

    Cardiac allograft vasculopathy (CAV) remains one of the leading causes of late graft failure and death. Cyclosporine microemulsion Neoral (CsA) had been used in heart transplantation (HTx) recipients. Meanwhile, Everolimus (EVL; Certican, Norvatis Pharmaceuticals; Basel, Switzerland) or mycophenolate mofetil (MMF) have been combined with CsA for maintenance treatment. We compared atherosclerosis in HTx patients showing CAV by intravascular ultrasound (IVUS) in two groups: the CE who received CsA, EVL, and steroid versus the CM group, who received CsA, MMF, and steroid. We explored IVUS parameters such as plaque thickness (PT), lumen circumference (LC), media adventitial circumference, lumen diameter (LD), and media adventitial diameter to characterize the atherosclerosis among CE versus CM groups. In this study, both the CE and CM groups showed increased plaque thickening in the first year posttransplantation (P data. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Intravascular ultrasound as a novel tool for the diagnosis and targeted treatment of functional popliteal artery entrapment syndrome

    Directory of Open Access Journals (Sweden)

    Anna E. Boniakowski, MD

    2017-06-01

    Full Text Available Functional popliteal artery entrapment syndrome can be difficult to diagnose, as the imaging modalities presently employed are designed to detect anatomic entrapment. We describe a novel imaging technique to aid in diagnosis in this cohort. A 22-year-old cyclist presented with exercise-limiting claudication. Magnetic resonance angiography with provocative maneuvers was nondiagnostic. Digital subtraction angiography revealed long-segment occlusion of the popliteal artery with plantar flexion; however, the specific site of compression remained unclear. Intravascular ultrasound allowed specific localization of compression and further confirmed the diagnosis. Thus, we report this as an adjunctive imaging modality to definitively diagnose functional popliteal artery entrapment syndrome and to assist in operative planning.

  2. Quantitative Ultrasound Measurements at the Heel

    DEFF Research Database (Denmark)

    Daugschies, M.; Brixen, K.; Hermann, P.

    2015-01-01

    Calcaneal quantitative ultrasound can be used to predict osteoporotic fracture risk, but its ability to monitor therapy is unclear possibly because of its limited precision. We developed a quantitative ultrasound device (foot ultrasound scanner) that measures the speed of sound at the heel...... with the foot ultrasound scanner reduced precision errors by half (p quantitative ultrasound measurements is feasible. (E-mail: m.daugschies@rad.uni-kiel.de) (C) 2015 World Federation for Ultrasound in Medicine & Biology....

  3. Antiatherosclerotic effects of long-term maximally intensive statin therapy after acute coronary syndrome: insights from Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin.

    Science.gov (United States)

    Puri, Rishi; Nissen, Steven E; Shao, Mingyuan; Ballantyne, Christie M; Barter, Philip J; Chapman, M John; Erbel, Raimund; Libby, Peter; Raichlen, Joel S; Uno, Kiyoko; Kataoka, Yu; Nicholls, Stephen J

    2014-11-01

    Patients with acute coronary syndromes (ACS) display diffuse coronary atheroma instability and heightened risk of early and late recurrent coronary events. We compared the long-term antiatherosclerotic efficacy of high-intensity statins in patients with ACS when compared with stable disease. Study of Coronary Atheroma by Intravascular Ultrasound: Effect of Rosuvastatin Versus Atorvastatin (SATURN) used serial intravascular ultrasound measures of coronary atheroma volume in patients treated with rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The overall effect of high-intensity statins on the change in coronary percent atheroma volume and major adverse cardiovascular events (death/nonfatal myocardial infarction/coronary revascularization) were evaluated in this post hoc analysis. When compared with non-ACS patients (n=678), patients with ACS (n=361) were younger, actively smoking, and have had a previous myocardial infarction (all P<0.001). At baseline, patients with ACS exhibited lower high-density lipoprotein cholesterol (43.5±11 versus 45.8±11 mg/dL; P=0.002), a higher apolipoprotein B: apolipoprotein A-1 ratio (0.90±0.24 versus 0.83±0.24; P<0.001) and greater percent atheroma volume (37.3±8.5% versus 35.9±8.1%; P=0.01) when compared with non-ACS patients. Despite similar achieved levels of lipid and inflammatory markers after high-intensity statin therapy, patients with ACS demonstrated greater percent atheroma volume regression than non-ACS patients (-1.46±0.14 versus -0.89±0.13; P=0.003). After propensity-weighted multivariable adjustment, baseline percent atheroma volume (P<0.001) and an ACS clinical presentation (P=0.02) independently associated with plaque regression. The 24-month major adverse cardiovascular events-free survival was similar between patients with ACS and non-ACS (90.6 versus 92.9%; P=0.25). Long-term high-intensity statin therapy caused greater plaque regression and comparable major adverse cardiovascular events rates in

  4. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  5. Joint learning of ultrasonic backscattering statistical physics and signal confidence primal for characterizing atherosclerotic plaques using intravascular ultrasound.

    Science.gov (United States)

    Sheet, Debdoot; Karamalis, Athanasios; Eslami, Abouzar; Noël, Peter; Chatterjee, Jyotirmoy; Ray, Ajoy K; Laine, Andrew F; Carlier, Stephane G; Navab, Nassir; Katouzian, Amin

    2014-01-01

    Intravascular Ultrasound (IVUS) is a predominant imaging modality in interventional cardiology. It provides real-time cross-sectional images of arteries and assists clinicians to infer about atherosclerotic plaques composition. These plaques are heterogeneous in nature and constitute fibrous tissue, lipid deposits and calcifications. Each of these tissues backscatter ultrasonic pulses and are associated with a characteristic intensity in B-mode IVUS image. However, clinicians are challenged when colocated heterogeneous tissue backscatter mixed signals appearing as non-unique intensity patterns in B-mode IVUS image. Tissue characterization algorithms have been developed to assist clinicians to identify such heterogeneous tissues and assess plaque vulnerability. In this paper, we propose a novel technique coined as Stochastic Driven Histology (SDH) that is able to provide information about co-located heterogeneous tissues. It employs learning of tissue specific ultrasonic backscattering statistical physics and signal confidence primal from labeled data for predicting heterogeneous tissue composition in plaques. We employ a random forest for the purpose of learning such a primal using sparsely labeled and noisy samples. In clinical deployment, the posterior prediction of different lesions constituting the plaque is estimated. Folded cross-validation experiments have been performed with 53 plaques indicating high concurrence with traditional tissue histology. On the wider horizon, this framework enables learning of tissue-energy interaction statistical physics and can be leveraged for promising clinical applications requiring tissue characterization beyond the application demonstrated in this paper. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Diagnostic accuracy of integrated intravascular ultrasound and optical coherence tomography (IVUS-OCT) system for coronary plaque characterization

    Science.gov (United States)

    Li, Jiawen; Ma, Teng; Mohar, Dilbahar; Correa, Adrian; Minami, Hataka; Jing, Joseph; Zhou, Qifa; Patel, Pranav M.; Chen, Zhongping

    2014-03-01

    Intravascular ultrasound (IVUS) imaging and optical coherence tomography (OCT), two commonly used intracoronary imaging modalities, play important roles in plaque evaluation. The combined use of IVUS (to visualize the entire plaque volume) and OCT (to quantify the thickness of the plaque cap, if any) is hypothesized to increase plaque diagnostic accuracy. Our group has developed a fully-integrated dual-modality IVUS-OCT imaging system and 3.6F catheter for simultaneous IVUS-OCT imaging with a high resolution and deep penetration depth. However, the diagnostic accuracy of an integrated IVUS-OCT system has not been investigated. In this study, we imaged 175 coronary artery sites (241 regions of interest) from 20 cadavers using our previous reported integrated IVUS-OCT system. IVUS-OCT images were read by two skilled interventional cardiologists. Each region of interest was classified as either calcification, lipid pool or fibrosis. Comparing the diagnosis by cardiologists using IVUSOCT images with the diagnosis by the pathologist, we calculated the sensitivity and specificity for characterization of calcification, lipid pool or fibrosis with this integrated system. In vitro imaging of cadaver coronary specimens demonstrated the complementary nature of these two modalities for plaques classification. A higher accuracy was shown than using a single modality alone.

  7. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  8. Safety and efficacy of intravascular ultrasound-guided inferior vena cava filter in super obese bariatric patients.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Barker, Michael; Macdonald, Kenneth G; Pender, John R; Chapman, William H

    2008-01-01

    The morbidly obese (body mass index >40 kg/m(2)) are at significant risk of postoperative venous thromboembolism (VTE). Pulmonary embolism is the leading cause of death after Roux-en-Y gastric bypass, approximating .5%. Because of the technical limitations with fluoroscopy and table weight limits, it has been our practice at our university-based bariatric center to offer intravascular ultrasound (IVUS)-guided inferior vena cava filter (IVCF) placement at Roux-en-Y gastric bypass to patients with a history of VTE, hypercoagulable state, or profound immobility. The hospital and outpatient records of all 594 patients who underwent Roux-en-Y gastric bypass from January 1, 2004 to October 31, 2006 were reviewed. The patients who had undergone concurrent IVUS-guided IVCF placement were selected. The co-morbidities, outcomes, and complications were recorded. Of the 594 patients, 31 (mean body mass index 71.2 +/- 2.96 kg/m(2)) had undergone concurrent IVUS-guided IVCF placement. The indications included a history of VTE (n = 5), a known hypercoagulable state (n = 2), and profound immobility (n = 25). The technical success rate was 96.8%. One filter was malpositioned in the iliac vein. No catheter site complications occurred. A ventilation/perfusion scan and computed tomography scan each detected pulmonary embolism in 2 surviving patients within 2 months postoperatively. Two patients died, 1 on postoperative day 8 and 1 on postoperative day 15 (6.4%). The mean follow-up time was 262.8 +/- 37.3 days. Autopsy excluded VTE or IVCF-related issues as the cause of death in both patients. These results suggest the efficacy of IVUS-guided IVCF placement in preventing mortality from pulmonary embolism in high-risk bariatric patients. IVUS-guided IVCF placement can be safely performed with an excellent success rate in high-risk patients who would not otherwise be candidates for intervention because of the technical limitations of fluoroscopy.

  9. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    International Nuclear Information System (INIS)

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-01-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization

  10. Impact of statins on progression of atherosclerosis: rationale and design of SATURN (Study of Coronary Atheroma by InTravascular Ultrasound: effect of Rosuvastatin versus AtorvastatiN).

    Science.gov (United States)

    Nicholls, Stephen J; Borgman, Marilyn; Nissen, Steven E; Raichlen, Joel S; Ballantyne, Christie; Barter, Philip; Chapman, M John; Erbel, Raimund; Libby, Peter

    2011-06-01

    Previous imaging studies have demonstrated that the beneficial impact of high-dose statins on the progression of coronary atherosclerosis associates with their ability to lower levels of low-density lipoprotein cholesterol (LDL-C) and C-reactive protein (CRP) and to raise high-density lipoprotein cholesterol (HDL-C). The Study of Coronary Atheroma by InTravascular Ultrasound: Effect of Rosuvastatin versus AtorvastatiN (SATURN, NCT00620542) aims to compare the effects of high-dose atorvastatin and rosuvastatin on disease progression. A total of 1385 subjects with established coronary artery disease (CAD) on angiography were randomized to receive rosuvastatin 40 mg or atorvastatin 80 mg for 24 months. The primary efficacy parameter will be the nominal change in percent atheroma volume (PAV), determined by analysis of intravascular ultrasound (IVUS) images of matched coronary artery segments acquired at baseline and at 24-month follow-up. The effect of statin therapy on plasma lipids and inflammatory markers, and the incidence of clinical cardiovascular events will also be assessed. The study does not have the statistical power to directly compare the treatment groups with regard to clinical events. Serial IVUS has emerged as a sensitive imaging modality to assess the impact of treatments on arterial structure. In this study, IVUS will be used to determine whether high-dose statins have different effects on plaque progression.

  11. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    NARCIS (Netherlands)

    J.M.R. Ligthart (Jürgen); M-C. Morice (Marie-Claude); P.J. de Feyter (Pim); M. Degertekin (Muzaffer); K. Tanabe (Kengo); J.E. Sousa (Eduardo); A. Colombo (Antonio); G. Guagliumi (Giulio); W. Wijns (William); W.K. Lindeboom (Wietze); P.W.J.C. Serruys (Patrick); A.C. Abizaid (Alexandre)

    2002-01-01

    textabstractBACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238

  12. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...

  13. Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: A meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

    NARCIS (Netherlands)

    Y. Zhang (Yaojun); V. Farooq (Vasim); H.M. Garcia-Garcia (Hector); C.V. Bourantas (Christos); N.-L. Tian (Nai-Liang); S.-J. Dong (Sheng-Jie); M. Li (Minghui); S. Yang (Shengyun); P.W.J.C. Serruys (Patrick); S.-L. Chen (Shao-Liang)

    2012-01-01

    textabstractAims: The impact of intravascular ultrasound (IVUS) guided coronary drug-eluting stent (DES) implantation on clinical outcomes remains controversial. A meta-analysis of the currently available clinical trials investi-gating IVUS-guided DES implantation was undertaken. Methods and

  14. Severe thrombocytopenia induced by iodinated contrast after coronary angiography: The use of gadolinium contrast and intravascular ultrasound as an alternative to guide percutaneous coronary intervention.

    Science.gov (United States)

    Cubero-Gómez, José María; Guerrero Márquez, Francisco J; Diaz-de la-Llera, Luis; Fernández-Quero, Mónica; Guisado-Rasco, Agustín; Villa-Gil-Ortega, Manuel

    2017-01-01

    Acute contrast-induced thrombocytopenia is a rare event with the use of modern low osmolarity iodinated contrast media. The pathophysiological mechanism that causes platelet counts to drop has not been identified, but an immunological mechanism is suspected due to cytotoxicity after previous exposure to contrast. We report the case of a 47-year-old male patient with acute severe thrombocytopenia due to iodinated contrast media exposure. His platelet count after the procedure with the highest amount of contrast was zero, which is the lowest reported platelet count to date. Percutaneous coronary revascularization under both intravascular ultrasound and gadolinium contrast guidance was performed without complications. The most feared complication after the use of gadolinium is nephrogenic systemic fibrosis, especially in patients on hemodialysis. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Controlled antegrade intimal tracking with subintimal balloon inflation as a novel bailout technique for chronic total occlusion after failed intravascular ultrasound-guided parallel wire technique.

    Science.gov (United States)

    Imai, Yuta; Yajima, Junji; Hosaka, Fumitaka

    Failure to cross with a guidewire is the most common reason for failure of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). In cases of CTO PCI with no interventional collaterals, an intravascular ultrasound (IVUS)-guided parallel wire technique is usually the last-resort procedure. Failure of this technique sometimes causes enlarged subintimal space, resulting in procedure failure. We present a successful second attempt at left anterior descending artery CTO PCI with no interventional collaterals. After IVUS-guided parallel wire technique failed with an enlarged subintimal space, successful antegrade wire crossing was achieved using controlled antegrade intimal tracking with balloon inflation in the subintimal space to deflect a second wire. This technique may be useful as a bailout strategy in otherwise-failed CTO PCI with an enlarged subintimal space. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Circulating Microparticles and Coronary Plaque Components Assessed by Virtual Histology Intravascular Ultrasound of the Target Lesion in Patients with Stable Angina.

    Directory of Open Access Journals (Sweden)

    Pil-Ki Min

    Full Text Available High levels of microparticles (MPs circulate in the blood of patients with atherosclerotic diseases where they can serve as potential biomarkers of vascular injury and cardiovascular outcome. We used virtual histology intravascular ultrasound (VH-IVUS to evaluate the relationship between the levels of circulating MPs and the coronary plaque composition in patients with stable angina. We included 35 patients with stable angina (22 men, age 64 ± 9 years and a de novo target lesion. Preintervention gray-scale and VH-IVUS analysis was performed across the target lesion. Volumetric analysis was performed over a 10-mm-long segment centered at the minimum luminal site. Blood samples were obtained from the femoral artery before coronary angioplasty. MPs were measured using a solid-phase capture assay from a commercial kit. We divided participants into either a low MPs group or high MPs group based on the median value of MPs. There was no significant difference in baseline characteristics between the groups. The plaque burden and remodeling index were similar between the groups. The presence of VH-IVUS-derived thin-cap fibroatheroma was not different between the groups. The percentage of the necrotic core (NC was significantly higher in the high MPs group than in the low MPs group, both in planar (17.0 ± 8.8% vs. 24.1 ± 6.9%, p = 0.012 and volumetric analyses (17.0 ± 4.8% vs. 22.1 ± 4.3%, p = 0.002. Circulating MPs were positively correlated with the percentage of the NC area at the minimal luminal site (r = 0.491, p = 0.003 and the percentage of the NC volume (r = 0.496, p = 0.002. Elevated levels of circulating MPs were associated with the amount of NC in the target lesion in those with stable angina, suggesting a potential role of circulating MPs as a biomarker for detecting unstable plaque in patients with stable angina.

  17. Intravascular photoacoustic imaging of human coronary atherosclerosis

    Science.gov (United States)

    Jansen, Krista; van der Steen, Antonius F. W.; Springeling, Geert; van Beusekom, Heleen M. M.; Oosterhuis, J. Wolter; van Soest, Gijs

    2011-03-01

    We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. We specifically imaged lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction. An integrated intravascular photoacoustics (IVPA) and ultrasound (IVUS) catheter with an outer diameter of 1.25 mm was developed. The catheter comprises an angle-polished optical fiber adjacent to a 30 MHz single-element transducer. The ultrasonic transducer was optically isolated to eliminate artifacts in the PA image. We performed measurements on a cylindrical vessel phantom and isolated point targets to demonstrate its imaging performance. Axial and lateral point spread function widths were 110 μm and 550 μm, respectively, for PA and 89 μm and 420 μm for US. We imaged two fresh human coronary arteries, showing different stages of disease, ex vivo. Specific photoacoustic imaging of lipid content, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm.

  18. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    DEFF Research Database (Denmark)

    Tearney, Guillermo J; Regar, Evelyn; Akasaka, Takashi

    2012-01-01

    The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the di...... the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease....

  19. A new method to quantify coronary calcification by intravascular ultrasound - the different patterns of calcification of acute myocardial infarction, unstable angina pectoris and stable angina pectoris.

    Science.gov (United States)

    Wang, Xiaofei; Lu, Chengzhi; Chen, Xin; Zhao, Xiangdong; Xia, Dasheng

    2008-11-01

    Intravascular ultrasound (IVUS) enables the identification of calcification with more details and quantification of calcification, but there is not a proper method to quantify the calcification with IVUS. Previous IVUS studies used arc or length of calcium, respectively, to quantify calcification, but calcium is determined by a combination of arc and length. We devised a new method to quantify calcium as arc area (AA) in the present study, and AA is two-dimensional and irrelevant to vessel size. We selected 201 patients with stable angina pectoris (SAP), unstable angina pectoris (UAP), or acute myocardial infarction (AMI) who underwent IVUS imaging of a de novo native atherosclerotic lesion considered to be the culprit lesion before percutaneous coronary intervention between December 2001 and December 2007. The culprit lesion site for analysis was the 10 mm-long segment including the smallest lumen cross-sectional area. The arc of each calcium deposit in each image was measured with a protractor centered on the lumen and the length of each calcium deposit was calculated with the number of images containing the calcium deposit minus 1, then multiplying 0.5 mm (the images were 0.5 mm apart). Finally, the AA was calculated by arc (degree) multiplying length (mm). The average number of calcium deposits in the culprit lesions of patients with acute myocardial infarction (AMI) was significantly larger than patients with SAP or UAP, and the number of calcium deposits of patients with SAP or UAP was almost the same (mean +/- SD, AMI 2.21 +/- 1.98, SAP 1.15 +/- 1.01, UAP 1.20 +/- 1.15, AMI versus SAP or UAP; p < 0.0005). The average AA per calcium deposit was significantly different in culprit lesions of patients with SAP and UAP or AMI, the calcium deposits were bigger in SAP than in UAP or AMI, and there were no differences between UAP and AMI (mean +/- SD, SAP 788.6 +/- 767.0 degree x mm, UAP 136.6 +/- 189.3 degree x mm, AMI 148.4 +/- 217.1 degree x mm, SAP versus UAP or

  20. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan); Kishimoto, Junichi; Iwata, Naoki [Tottori University Hospital, Division of Clinical Radiology, Yonago (Japan)

    2015-09-15

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  1. Assessment of carotid plaque composition using fast-kV switching dual-energy CT with gemstone detector: comparison with extracorporeal and virtual histology-intravascular ultrasound

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kuya, Keita; Ohta, Yasutoshi; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Kishimoto, Junichi; Iwata, Naoki

    2015-01-01

    The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). Effective Z maps generated by GSI can detect vulnerable carotid plaque materials. (orig.)

  2. Acute myocardial infarction due to spontaneous, localized, acute dissection of the sinus of Valsalva detected by intravascular ultrasound and electrocardiogram-gated computed tomography.

    Science.gov (United States)

    Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki

    2016-09-01

    A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.

  3. Comprehensive analysis of intravascular ultrasound and angiographic morphology of culprit lesions between ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome.

    Science.gov (United States)

    Takaoka, Naoko; Tsujita, Kenichi; Kaikita, Koichi; Hokimoto, Seiji; Mizobe, Michio; Nagano, Masahide; Horio, Eiji; Sato, Koji; Nakayama, Naoki; Yoshimura, Hiromi; Yamanaga, Kenshi; Komura, Naohiro; Kojima, Sunao; Tayama, Shinji; Nakamura, Sunao; Ogawa, Hisao

    2014-02-15

    Some plaques lead to ST-segment elevation myocardial infarction (STEMI), whereas others cause non-ST-segment elevation acute coronary syndrome (NSTEACS). We used angiography and intravascular ultrasound (IVUS) to investigate the difference of culprit lesion morphologies in ACS. Consecutive 158 ACS patients whose culprit lesions were imaged by preintervention IVUS were enrolled (STEMI=81; NSTEACS=77). IVUS and angiographic findings of the culprit lesions, and clinical characteristics were compared between the groups. There were no significant differences in patients' characteristics except for lower rate of statin use in patients with STEMI (20% vs 44%, p=0.001). Although angiographic complex culprit morphology (Ambrose classification) and thrombus were more common in STEMI than in NSTEACS (84% vs 62%, p=0.002; 51% vs 5%, pSYNTAX score was lower in STEMI (8.6 ± 5.4 vs 11.5 ± 7.1, p=0.01). In patients with STEMI, culprit echogenicity was more hypoechoic (64% vs 40%, p=0.01), and the incidence of plaque rupture, attenuation and "microcalcification" were significantly higher (56% vs 17%, pMorphological feature (outward vessel remodeling, plaque buildup and IVUS vulnerability of culprit lesions) might relate to clinical presentation in patients with ACS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies.

    Science.gov (United States)

    Steinvil, Arie; Zhang, Yao-Jun; Lee, Sang Yeub; Pang, Si; Waksman, Ron; Chen, Shao-Liang; Garcia-Garcia, Hector M

    2016-08-01

    The use of intravascular ultrasound (IVUS) guidance for drug-eluting stent (DES) optimization is limited by the number of adequately powered randomized control trials (RCTs). We performed an updated meta-analysis, including data from recently published RCTs and observational studies, by reviewing the literature in Medline and the Cochrane Library to identify studies that compared clinical outcomes between IVUS-guided and angiography-guided DES implantation from January 1995 to January 2016. This meta-analysis included 25 eligible studies, including 31,283 patients, of whom 3192 patients were enrolled in 7 RCTs. In an analysis of all 25 studies, the summary results for all the events analyzed were significantly in favor of IVUS-guided DES implantation [major adverse cardiac events (MACE, odds ratio [OR] 0.76, 95% confidence intervals [CI]: 0.70-0.82, PDES implantation was found only for MACE (OR 0.66, 95% CI: 0.52-0.84, P=0.001), TLR (OR 0.61, 95% CI: 0.43-0.87, P=0.006), and TVR (OR 0.61, 95% CI: 0.41-0.90, P=0.013). IVUS-guided percutaneous coronary intervention was associated with better overall clinical outcomes than angiography-guided DES implantation. However, in a solely RCT meta-analysis, this benefit was mainly driven by reduced rates of revascularizations. Copyright © 2016. Published by Elsevier Ireland Ltd.

  5. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

    Science.gov (United States)

    Rahman, Shahid; Leesar, Tara; Cilingiroglu, Mehmet; Effat, Mohamed; Arif, Imran; Helmy, Tarek; Leesar, Massoud A

    2013-09-01

    Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation. A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI. In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p impact on the MV stent volume or symmetry. This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials.

    Science.gov (United States)

    Bavishi, Chirag; Sardar, Partha; Chatterjee, Saurav; Khan, Abdur Rahman; Shah, Arpit; Ather, Sameer; Lemos, Pedro A; Moreno, Pedro; Stone, Gregg W

    2017-03-01

    The relative outcomes of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) compared with angiography-guided PCI with drug-eluting stent (DES) in complex lesions have not been established. We sought to compare the efficacy and safety of IVUS-guided PCI with angiography-guided PCI in patients with complex coronary lesions treated with DES. Electronic databases were searched to identify all randomized trials comparing IVUS-guided vs angiography-guided DES implantation. We evaluated major adverse cardiac events (MACE), all-cause and cardiovascular death, myocardial infarction, target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis outcomes at the longest reported follow-up. Random-effects modeling was used to calculate pooled relative risk (RR) and 95% CIs. Eight trials comprising 3,276 patients (1,635 IVUS-guided and 1,641 angiography-guided) enrolling only patients with complex lesions were included. Mean follow-up was 1.4±0.5years. Compared with angiography-guided PCI, patients undergoing IVUS-guided PCI had significantly lower MACE (RR 0.64, 95% CI 0.51-0.80, P=.0001), TLR (RR 0.62, 95% CI 0.45-0.86, P=.004), and TVR (RR 0.60, 95% CI 0.42-0.87, P=.007). There were no significant differences for stent thrombosis, cardiovascular death, or all-cause death. In meta-regression analysis, IVUS-guided PCI was of greatest benefit in reducing MACE in patients with acute coronary syndromes, diabetes, and long lesions. The present meta-analysis demonstrates a significant reduction in MACE, TVR, and TLR with IVUS-guided DES implantation in complex coronary lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Lodi-Junqueira Lucas

    2012-09-01

    Full Text Available Abstract Background The role of intravascular ultrasound (IVUS in percutaneous coronary interventions (PCI is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies. Methods A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies. Results Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10, non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35 and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16. An analysis of the previous published meta-analysis strongly suggested the presence of publication bias. Conclusions There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.

  8. Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: the Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2008-01-01

    AIMS: Patients with diabetes have increased risk of in-stent restenosis after coronary stent implantation owing to neointimal hyperplasia (NIH). The aim of the study was to evaluate the extent and distribution of NIH with intravascular ultrasound (IVUS) after coronary artery stenting with sirolimus......-eluting (Cypher) or paclitaxel-eluting (Taxus) stents in diabetic patients. METHODS AND RESULTS: One hundred and thirty diabetic patients were randomized to Cypher or Taxus stent implantation. IVUS was performed at 8 month follow-up. NIH volume was significantly reduced in the Cypher group when compared...

  9. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology.

    Science.gov (United States)

    Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S

    2016-05-01

    Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary

  10. The use of intravascular ultrasound imaging to improve use of inferior vena cava filters in a high-risk bariatric population.

    Science.gov (United States)

    Kardys, Clark M; Stoner, Michael C; Manwaring, Mark L; Bogey, William M; Parker, Frank M; Powell, Steve

    2007-12-01

    Pulmonary embolism is the leading cause of death after gastric bypass procedures for obesity, approximating 0.5% to 4%. All bariatric patients, but especially the super-obese, which have a body mass index (BMI) >50 kg/m(2), are at significant risk for postoperative venous thromboembolism (VTE). Visualization and weight limitations of fluoroscopy tables exclude most bariatric and all super-obese patients from inferior vena cava (IVC) filter placement using fluoroscopy. Intravascular ultrasound (IVUS)-guided IVC filter placement is the only modality that allows these high-risk patients to have an IVC filter placed. Hospital and outpatient records of the 494 patients who underwent gastric bypass procedures from January 1, 2004, to May 31, 2006, were reviewed. All patients who had concurrent IVC filter placement with the use of IVUS guidance were selected. Comorbidities, outcomes, and complications were recorded. We identified 27 patients with mean BMI of 70 +/- 3 kg/m(2); of these, 25 were super-obese (BMI >50 kg/m(2)). Procedures included five laparoscopic and 22 open gastric bypass operations. All patients underwent concurrent IVC filter placement using IVUS guidance. In addition to super-obesity, indications for IVC filter placement included history of VTE (n = 4), known hypercoagulable state (n = 2), and profound immobility (n = 21). Mean follow up was 293 +/- 40 days. Technical success rate was 96.3%. There were no catheter site complications. In one surviving patient, a nonfatal pulmonary embolism was detected by computed tomography 2 months postoperatively. Two patients died, and autopsy excluded VTE as the cause of death in both. This study suggests efficacy of IVUS-guided IVC filter placement in preventing mortality from pulmonary embolism in high-risk bariatric patients, including the super-obese. IVUS-guided IVC filter placement can be safely performed with an excellent success rate in all bariatric patients, including the super-obese, who otherwise would

  11. Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis.

    Science.gov (United States)

    Nerlekar, Nitesh; Cheshire, Caitlin J; Verma, Kunal P; Ihdayhid, Abdul-Rahman; McCormick, Liam M; Cameron, James D; Bennett, Martin R; Malaiapan, Yuvaraj; Meredith, Ian T; Brown, Adam J

    2017-01-20

    Our aim was to assess whether intravascular ultrasound (IVUS) improves clinical outcomes during implantation of first- and second-generation drug-eluting stents (DES). IVUS guidance is associated with improved clinical outcomes during DES implantation, but it is unknown whether this benefit is limited to either first- or second-generation devices. MEDLINE, EMBASE and PubMed were searched for studies comparing outcomes between IVUS- and angiography-guided PCI. Among 909 potentially relevant studies, 15 trials met the inclusion criteria. The primary endpoint was MACE, defined as death, myocardial infarction, target vessel/lesion revascularisation (TVR/TLR) or stent thrombosis (ST). Summary estimates were obtained using Peto modelling. In total, 9,313 patients from six randomised trials and nine observational studies were included. First-generation DES were implanted in 6,156 patients (3,064 IVUS-guided and 3,092 angiography-guided) and second-generation in 3,157 patients (1,528 IVUS-guided and 1,629 angiography-guided). IVUS guidance was associated with a significant reduction in MACE (odds ratio [OR] 0.73, 95% CI: 0.64-0.85, pDES (0.57, 95% CI: 0.43-0.77, pDES, IVUS guidance was associated with significantly lower rates of cardiac death (OR 0.33, 95% CI: 0.14-0.78, p=0.02), TVR (OR 0.47, 95% CI: 0.28-0.79, p=0.006), TLR (OR 0.61, 95% CI: 0.42-0.90, p=0.01) and ST (OR 0.31, 95% CI: 0.12-0.78, p=0.02). Cumulative meta-analysis highlighted progressive temporal benefit towards IVUS-guided PCI to reduce MACE (OR 0.60, 95% CI: 0.48-0.75, pDES platforms. These data support the use of IVUS guidance in contemporary revascularisation procedures using second-generation DES.

  12. Ultrasound transmission measurements through the os calcis.

    Science.gov (United States)

    Zagzebski, J A; Rossman, P J; Mesina, C; Mazess, R B; Madsen, E L

    1991-08-01

    A method of measuring ultrasonic propagation in the os calcis was devised for assessing bone properties in humans. Speed-of-sound (SOS) and broadband ultrasound attenuation (BUA) were measured using broadband acoustic pulses transmitted and received by a pair of focused transducers. The transducers are mounted coaxially in a water tank with the subject's heel in between. Reproducibility of results in an adult male was 10% for the BUA and 1.2% for the SOS. Both SOS and BUA changed when the transmission path through the os calcis was varied. For a population of normal male subjects, SOS and BUA were correlated with densitometry results on the os calcis, but less well correlated to area density at remote sites.

  13. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M

    2017-01-01

    ultrasound, to deliver accurate measurements seems promising. To examine the reliability and validity of navigation ultrasound for length measurements of the clavicle, a study was performed using length measurements performed before forensic autopsies from 2012 to 2013. In total, 38 bodies with a median age...

  14. Computational fluid dynamics using in vivo ultrasound blood flow measurements

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    This paper presents a model environment for construction of patient-specific computational fluid dynamic (CFD) models for the abdominal aorta (AA). Realistic pulsatile velocity waveforms are employed by using in vivo ultrasound blood flow measurements. Ultrasound is suitable for acquisition...

  15. Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study.

    Science.gov (United States)

    Arnold, Roman; Villa, Adolfo; Gutiérrez, Hipólito; Sánchez, Pedro L; Gimeno, Federico; Fernández, Maria E; Gutiérrez, Oliver; Mota, Pedro; Sánchez, Ana; García-Frade, Javier; Fernández-Avilés, Francisco; San Román, Jose A

    2010-06-01

    We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy. Copyright 2010 Mosby, Inc. All rights reserved.

  16. Comparison of change in coronary atherosclerosis in patients with stable versus unstable angina pectoris receiving statin therapy (from the Treatment With Statin on Atheroma Regression Evaluated by Intravascular Ultrasound With Virtual Histology [TRUTH] study).

    Science.gov (United States)

    Nozue, Tsuyoshi; Yamamoto, Shingo; Tohyama, Shinichi; Fukui, Kazuki; Umezawa, Shigeo; Onishi, Yuko; Kunishima, Tomoyuki; Sato, Akira; Nozato, Toshihiro; Miyake, Shogo; Takeyama, Youichi; Morino, Yoshihiro; Yamauchi, Takao; Muramatsu, Toshiya; Hibi, Kiyoshi; Terashima, Mitsuyasu; Michishita, Ichiro

    2013-04-01

    Although statin-induced regression in coronary atherosclerosis seems to be greater in patients with acute coronary syndrome than in those with stable coronary artery disease, no reports have examined this. The purpose of the present study was to compare the changes in coronary atherosclerosis in patients with stable versus unstable angina pectoris (AP). The effects of 8-month statin therapy on coronary atherosclerosis were evaluated using virtual histology intravascular ultrasound, and analyzable intravascular ultrasound data were obtained from 119 patients (83 patients with stable AP and 36 with unstable AP). A significant decrease in plaque volume was observed in patients with unstable AP (-2.2%, p = 0.02) but not in patients with stable AP. A significant increase in the necrotic-core component (0.30 mm(3)/mm, p = 0.009) was observed only in patients with unstable AP. Significant positive correlations were observed between the percentage of change in platelet-activating factor acetylhydrolase and the percentage of change in plaque volume (r = 0.346, p = 0.05) in patients with unstable AP. No significant correlations were observed in patients with stable AP. Multivariate regression analyses showed that a reduction in platelet-activating factor acetylhydrolase was associated with regression in coronary atherosclerosis, particularly of the fibrous component (β = 0.443, p = 0.003), in patients with unstable AP. In conclusion, regression of the coronary artery plaque volume was greater, although statin therapy did not halt the increases in plaque vulnerability, in patients with unstable AP compared to those with stable AP. A reduction in the serum platelet-activating factor acetylhydrolase level was associated with regression in coronary atherosclerosis, particularly the fibrous plaque volume, in patients with unstable AP. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    Science.gov (United States)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  18. Extramedullary Hematopoiesis in Uterine Leiomyoma Associated with Numerous Intravascular Thrombi

    Directory of Open Access Journals (Sweden)

    Xiaoyan Cui

    2014-01-01

    Full Text Available We report a case of extramedullary hematopoiesis (EMH in uterine leiomyoma and associated numerous intravascular thrombi. A 29-year-old nulliparous female presented with heavy vaginal bleeding and a hematocrit of 22%. No bone marrow biopsy has been performed. She had a history of uterine leiomyomata and menorrhagia for a year. A transvaginal ultrasound confirmed the presence of a uterine leiomyoma. The patient was treated conservatively with oral contraceptive pills due to desire for fertility. However, she continued to have heavy vaginal bleeding and developed bilateral upper extremity deep vein thrombosis and multiple superficial vein thromboses after two months. An exploratory laparotomy with uterine myomectomy was performed. Gross examination of the specimen revealed a single nodular mass measuring 10.0×9.5×7.5 cm with a white-tan swirling cut surface. Microscopic examination revealed benign smooth muscle consistent with leiomyoma and numerous intravascular thrombi both with areas of EMH. Immunohistochemical stains confirmed the presence of all three benign lineages of hematopoietic cells. Occurrence of EMH in uterine leiomyoma and intravascular thrombi is very rare. It may be related to systemic hematopoietic stimulation due to severe chronic anemia and local presence of hematopoietic growth factors and/or cytokines.

  19. A simple technique to measure regional cerebral blood flow during intravascular ballon clamping

    International Nuclear Information System (INIS)

    Furuhata, Shigeru; Kubo, Atsushi; Kawase, Takeshi; Ibata, Yukio; Toya, Shigeo

    1988-01-01

    A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a ballon clamping test was performed before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine ( 123 I-IMP). When the ballon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a 'memory of blood flow' during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123 I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test. (author)

  20. A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements

    International Nuclear Information System (INIS)

    Have, A G ten; Gijsen, F J H; Wentzel, J J; Slager, C J; Serruys, P W; Steen, A F W van der

    2006-01-01

    Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its heat production were varied. Concerning the heat transfer, the thermal properties of the lipid core and the location of the vasa vasorum were studied. The heat source location was the main determinant of the lumen wall temperature distribution. The strongest effect was noted when the heat producing macrophages were located in the shoulder region leading to focal spots of higher temperature. The maximal lumen wall temperature was mainly determined by the heat production of the macrophages and the cooling effect of blood. The insulating properties of the lipid core increased lumen wall temperatures when the heat source was located in the cap and the presence of vasa vasorum lowered the temperatures. These results show that the lumen wall temperature distribution is influenced by vulnerable plaque composition and that intracoronary thermography techniques require a high spatial resolution. To be able to couple temperature measurements to plaque vulnerability, intracoronary thermography needs to be combined with an imaging modality

  1. Measurement of ultrasound power using a calorimeter

    Science.gov (United States)

    Morgado, G.; Miqueleti, S.; Costa-Felix, R. P. B.

    2018-03-01

    This paper presents a comparison between the ultrasound power of a 1 MHz therapy equipment on the water using a calorimeter and a radiation force balance. For a range of 5 to 10 W, the results presented a normalized error less than 1, disclosing compatibility of the results from the developed system and the radiation force balance. The calorimetric method might be used as a faster and cheaper means for the verification of the ultrasonic power emitted by an equipment for physiotherapeutic treatment.

  2. Ultrasound as an Outcome Measure in Gout. A Validation Process by the OMERACT Ultrasound Working Group

    DEFF Research Database (Denmark)

    Terslev, Lene; Gutierrez, Marwin; Schmidt, Wolfgang A

    2015-01-01

    OBJECTIVE: To summarize the work performed by the Outcome Measures in Rheumatology (OMERACT) Ultrasound (US) Working Group on the validation of US as a potential outcome measure in gout. METHODS: Based on the lack of definitions, highlighted in a recent literature review on US as an outcome tool...

  3. Is the inferior vena cava diameter measured by bedside ultrasonography valuable in estimating the intravascular volume in patients with septic shock?

    Directory of Open Access Journals (Sweden)

    Mortaza Talebi Doluie

    2016-07-01

    Full Text Available Introduction:Resuscitation should be initiated immediately in shock. Early goal-directed therapy is an established algorithm for the resuscitation in septic shock. The first step is to maintain cardiac preload. Central venous pressure (CVP plays an important role in goal-directed therapy. Central venous catheterization is invasive and time-consuming in emergency conditions. There are some alternative and noninvasive methods for estimating the intravascular volume such as measuring the inferior vena cava (IVC diameter by ultrasonography. Methods: We searched PubMed, Google scholar, and Scopus databases with keywords (central venous pressure OR venous pressure OR CVP AND (ultrasonography OR sonography AND (sepsis OR septic shock AND (inferior vena cava OR IVC.Result: The search resulted in 2550 articles. The articles were appraised regarding the relevance, type of article, and statistical methods. Finally, 12 articles were selected. The number of patients was between 30 and 83 cases (mean age=57-67 years, intubated and non-intubated in each study. The IVC diameter was measured in respiratory cycle by bedside ultrasonography in longitudinal subxiphoid view and caval index was calculated, then they were compared with the CVP measured by central venous catheter.Discussion: CVP is an indicator of intravascular fluid status and right heart function. CVP measurement is an invasive method and of course with some complications. The IVC is the biggest vein of venous system with low-pressure; expansion of the vein reflects intravascular volume.Conclusion: It seems that IVC diameter measured by ultrasonography could be used as an alternative method for the determination of CVP in the emergency or critical patients.

  4. The Correlation Between Ultrasound-Measured Fetal Heart Rate ...

    African Journals Online (AJOL)

    ... for fetal heart rate (FHR) and the relationship between fetal heart rate and gestational age (GA) by 2–D ultrasound. Crown rump length measurement was used for estimating GA in the first trimester while femur length and biparietal diameter measurements were used for estimating GA in the second and third trimesters.

  5. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    Objective: To determine the accuracy of various ultrasound formulas for measuring the testicular volume in humans by comparing the resultant measurements with the actual testicular volume. Subjects and methods: The testicular volume of 121 testes from 62 patients with prostate cancer (mean age 72.7 ± 9.4) was ...

  6. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  7. Characterization and morphology of atherosclerotic plaque of coronary arteries: utility of electron-beam tomography to detect non-calcified plaque: a comparison with conventional coronary angiography and intravascular ultrasound.

    Science.gov (United States)

    Funabashi, Nobusada; Misumi, Kazuo; Ohnishi, Hiroyuki; Asano, Miki; Komuro, Issei

    2007-01-31

    Electron-beam tomography (EBT) may provide useful information about characterization and morphology of atherosclerotic plaque of coronary arteries. Twenty-six subjects (20 male, 6 female) with suspected coronary heart disease had two routine (r) and one enhanced (e) EBT scans to detect non-calcified plaque (NCP) in the coronary arterial lumen, and were compared with conventional coronary angiograms (CAG) and intravascular ultrasound (IVUS). Three had the sites, which did not have high CT values suggesting calcification in rEBT, nor which was not enhanced by contrast material in eEBT. One had the site with positive CT values that were supposed to be the proliferation intima or organized thrombus and at the corresponding site mixed plaque was observed in the IVUS image. The other two had the site with negative CT values that were supposed to be fat tissue with significant stenosis in CAG. We also made the cross-sectional images of the vessel and the morphology of the NCP, which projected into the lumen, could be evaluated. We could detect the NCP, differentiate fat tissue from soft tissue and evaluate the morphology of the plaque in EBT.

  8. Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.

    Science.gov (United States)

    Mariani, José; Guedes, Cristiano; Soares, Paulo; Zalc, Silvio; Campos, Carlos M; Lopes, Augusto C; Spadaro, André G; Perin, Marco A; Filho, Antonio Esteves; Takimura, Celso K; Ribeiro, Expedito; Kalil-Filho, Roberto; Edelman, Elazer R; Serruys, Patrick W; Lemos, Pedro A

    2014-11-01

    The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI). To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast. A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months. The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p MOZART]; NCT01947335). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  10. Correlation between self-reported gestational age and ultrasound measurements

    DEFF Research Database (Denmark)

    Olesen, Annette Wind; Westergaard, Jes Grabow; Thomsen, Sten Grove

    2004-01-01

    BACKGROUND: We studied the agreement between different measurements of gestational age, i.e. self-reported gestational age in the Danish National Birth Cohort Study, ultrasound-estimated gestational age from the medical records in one Danish county and gestational age from the Danish National...... and the gestational ages based on corrected last menstrual period did not differ significantly. CONCLUSION: The self-reported gestational age in The Danish National Birth Cohort is in good concordance both with data from the National Hospital Discharge Register and with ultrasound-estimated gestational age....

  11. Comparison of central corneal thickness in dogs measured by ultrasound pachymetry and ultrasound biomicroscopy.

    Science.gov (United States)

    Martín-Suárez, Eva; Galán, Alba; Morgaz, Juan; Guisado, Alicia; Gallardo, José María; Gómez-Villamandos, Rafael Jesús

    2018-02-01

    Ultrasound pachymetry (UP) is currently the most common technique used to evaluate central corneal thickness (CCT). New devices which allow assessment of CCT without corneal contact have been compared, but there are discrepancies among instruments. The aim of this study was to compare CCT measurements obtained by UP and ultrasound biomicroscopy (UBM) in 28 eyes of 14 healthy Beagles dogs. Mean CCT±standard deviation (SD) were 552±63μm for UP and 551±55μm for UBM. UBM showed both a fixed and proportional bias when compared to ultrasound pachymetry, but this was not considered to be clinically important. Measured CCT did not differ between UP and UBM (P=0.796). The intra-class correlation coefficient indicated a strong agreement between methods (0.990). The CCT measurements between left (548±61μm) and right (555±59μm) eyes did not differ (P=0.760). Male dogs had higher CCT measurements than female dogs (P=0.038). Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    Full Text Available OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM com Tecnécio 99m-MIBI (MIBI e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ e o ultra-som intracoronário (UIC como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC, encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E% de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79% e média de 44,20%, pOBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA and intravascular ultrasound (IVUS. METHODS: Seventy patients with coronary artery disease (CAD referred for myocardial perfusion scintigraphy (MPS with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG, and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%, mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%, p<0.05. Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA. Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD and minimal lumen area

  13. Comparison of Simulated and Measured Non-linear Ultrasound Fields

    DEFF Research Database (Denmark)

    Du, Yigang; Jensen, Henrik; Jensen, Jørgen Arendt

    2011-01-01

    In this paper results from a non-linear AS (angular spectrum) based ultrasound simulation program are compared to water-tank measurements. A circular concave transducer with a diameter of 1 inch (25.4 mm) is used as the emitting source. The measured pulses are rst compared with the linear...... simulation program Field II, which will be used to generate the source for the AS simulation. The generated non-linear ultrasound eld is measured by a hydrophone in the focal plane. The second harmonic component from the measurement is compared with the AS simulation, which is used to calculate both...... fundamental and second harmonic elds. The focused piston transducer with a center frequency of 5 MHz is excited by a waveform generator emitting a 6-cycle sine wave. The hydrophone is mounted in the focal plane 118 mm from the transducer. The point spread functions at the focal depth from Field II...

  14. Intravascular pulmonary metastases

    International Nuclear Information System (INIS)

    Shepard, J.A.O.; Moore, E.H.; Templeton, P.A.; McLoud, T.C.

    1988-01-01

    The diagnosis of intravascular metastatic tumor emboli to the lungs is rarely made. The authors present a characteristic radiographic finding of intravascular lung metastases that they observed in four patients with diagnoses or right atrial myoxoma, invasive renal cell carcinoma, invasive pelvic osteosarcoma, and recurrent pelvic chondrosarcoma. Substantiation of intravascular pulmonary metastases was achieved by means of autopsy, pulmonary artery biopsy, and surgical documentation of tumor invasion of the inferior vena cava or pelvic veins. In all four cases, chest computed tomography (CT) demonstrated branching, beaded opacities extending from the hila into the periphery of the lung in the distribution of pulmonary arteries. In one case, similar findings were observed in magnetic resonance (MR) images of the chest. Follow-up studies in three cases showed progressive enlargement and varicosity of the abnormal pulmonary artery consistent with proliferation of intravascular tumor. In the case of metastatic osteosarcoma, intraluminal ossification was also observed at CT. In three of four cases, pulmonary infarction was demonstrated in the distribution of the abnormal pulmonary arteries seen at CT as small, peripheral, wedge-shaped opacities. The demonstration of progressively dilated and beaded pulmonary arteries in patients with extrathoracic malignancies is suggestive of intravascular lung metastases, particularly when accompanied by peripheral infarction

  15. No change in impedance upon intravascular injection of D5W.

    Science.gov (United States)

    Chin, James; Tsui, Ban C H

    2010-06-01

    Electrical impedance increases following test injections of non-conducting solutions around nerves; however, this increase should diminish rapidly with intravascular needle placement, wherein the systemic circulation will dissipate the solution. For this observational study, we hypothesized that the impedance increases significantly at the perineural space after an injection of 5% dextrose in water (D5W), but that it does not increase correspondingly at the intravascular location After Ethics Research Board approval, electrical impedance was measured by a nerve stimulator displaying resistance, Stimuplex HNS 12, before and during (30 sec) an injection of D5W 3 mL: 1) during intravenous cannula placement using an insulated stimulating needle sheathed in its plastic cannula, MultiSet NanoLine with 18G needle; and 2) during needle placement (Pajunk 22G insulated) for an ultrasound-guided supraclavicular block in patients undergoing hand surgery. The impedance changes at each location were analyzed and compared. Data were collected from 16 patients. Baseline impedance was lower intravascularly (mean 16.5 +/- standard deviation 7.2 kOmega) compared with perineurally (23.5 +/- 8.3 kOmega) (P = 0.037). Peak impedance after intravascular D5W injection was 20.1 +/- 6.8 kOmega, which was not a significant change (P = 0.15). In contrast, peak impedance after perineural D5W injection was 58.6 +/- 29.1 kOmega, an increase of 35.1 +/- 26.4 kOmega (155 +/- 117%), and then it reached a plateau of 36.7 +/- 19.6 kOmega. The increase in impedance was significantly greater at the perineural location (P < 0.0001). The absence of a significant increase in impedance upon injection of D5W prior to injection of local anesthetic may provide useful information to warn of intravascular injection.

  16. Ultrasound transmission measurements for tensile strength evaluation of tablets.

    Science.gov (United States)

    Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko

    2011-05-16

    Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Quantitative Measurements using Ultrasound Vector Flow Imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2016-01-01

    scanner for pulsating flow mimicking the femoral artery from a CompuFlow 1000 pump (Shelley Medical). Data were used in four estimators based on directional transverse oscillation for velocity, flow angle, volume flow, and turbulence estimation and their respective precisions. An adaptive lag scheme gave...... the ability to estimate a large velocity range, or alternatively measure at two sites to find e.g. stenosis degree in a vessel. The mean angle at the vessel center was estimated to 90.9◦±8.2◦ indicating a laminar flow from a turbulence index being close to zero (0.1 ±0.1). Volume flow was 1.29 ±0.26 mL/stroke...... (true: 1.15 mL/stroke, bias: 12.2%). Measurements down to 160 mm were obtained with a relative standard deviation and bias of less than 10% for the lateral component for stationary, parabolic flow. The method can, thus, find quantitative velocities, angles, and volume flows at sites currently...

  18. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...... access blood flow measured before and after every procedure. Two methods, catheter-based thermodilution and Doppler ultrasound, were compared to the reference method of ultrasound dilution. Catheter-based thermodilution and Doppler ultrasound were performed during the endovascular procedures while flow...

  19. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  20. Ultrasound

    Science.gov (United States)

    ... chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. ... by: Jason Levy, MD, Northside Radiology Associates, Atlanta, GA. Also ...

  1. [Intravascular endothelioma (author's transl)].

    Science.gov (United States)

    Vanĕk, J

    1978-01-01

    A 76-year-old woman developed a slowly growing lesion over the right index and the adjacent part of the metacarpus. A cell proliferation filling up the skin veins was classified as intravascular endothelioma. This rather rare oncological entity with a good prognosis should be differentiated from peculiar pattern occasionally seen in organisation of thrombi as well as malignant endothelial tumours.

  2. Distal Radius Quantitative Ultrasound Measurements and Related Factors

    Directory of Open Access Journals (Sweden)

    Özden Özyemiflçi Taflk›ran

    2011-04-01

    Full Text Available Aim: To investigate the quantitative ultrasound measurements and determine the related demographic, clinical and life style parameters. Material and Methods: A questionnaire including demographic features, systemic diseases, physical activity levels and other risk factors for osteoporosis was completed. Measurements of quantitative ultrasound (QUS were performed. Speed of sound (SOS (m/sec measurements were taken at the distal 1/3 radius of the nondominant extremity. Results: Among 2347 persons whom QUS measurements and questionnaires were completed, those aged 35 years and older and that were not taking antiosteoporotic treatment (N= 1867; 1654 women, 213 men were included for the analysis. Mean age of the participants were 52.1±10.7 years and mean SOS scores were 4142.8±185.8 m/sec. The variables that were statistically significant in either independent samples t test or analysis of variance were put in the linear regression analysis. In women, age, years since menopause and duration of lactation were independent predictors for SOS scores (constant= 4367.9 m/sec, age B: -3.8, ß: -0.197, p: 0.01; years since menopause: B: -3.9, ß: -0.211, p: 0.006; duration of lactation B: -0.4, ß: -0.086, p: 0.037. In men, age and level of education affected SOS scores independently (constant= 4271.3 m/sec, age B: -3.8, ß: -0.277, p: 0.001; level of education: B: 18.8, ß: 0.144, p: 0.036. Conclusion: Increasing age is associated with decrements in speed of sound measured by quantitative ultrasound at distal radius. It is important to give education about preventive measures on bone metabolism, especially during the lactation period. (Turkish Journal of Osteoporosis 2011;17:1-5

  3. Validation of a novel ultrasound measurement of achilles tendon length

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Riecke, Anja Falk; Boesen, Anders

    2014-01-01

    PURPOSE: A clinically applicable and accurate method for measuring Achilles tendon length is needed to investigate the influence of elongation of the Achilles tendon after acute rupture. The purpose of this study was to develop and validate an ultrasonographic (US) length measurement...... of the Achilles tendon-aponeurosis complex. METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imaging (MRI) and US. The length from calcaneus to the medial head of m. Gastrocnemius was measured by three independent US examiners. Repeated US measurements were performed and compared...... to be further assessed in the setting of acute Achilles tendon rupture. CLINICAL RELEVANCE: This new ultrasound measurement might allow for length measurement of ruptured Achilles tendons in the acute and chronic state after rupture. LEVEL OF EVIDENCE: II....

  4. Measurement of Angle Kappa Using Ultrasound Biomicroscopy and Corneal Topography.

    Science.gov (United States)

    Yeo, Joon Hyung; Moon, Nam Ju; Lee, Jeong Kyu

    2017-06-01

    To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbscan II. The mean patient age was 36.4 ± 13.8 years. The average angle kappa measured by Orbscan II was 3.98° ± 1.12°, while the average angle kappa calculated with UBM and corneal topography was 3.19° ± 1.15°. The difference in angle kappa measured by the two methods was statistically significant (p topography to calculate the angle kappa. This method is convenient to use and allows for measurement of the angle kappa without an expensive device. © 2017 The Korean Ophthalmological Society

  5. A thermal technique for local ultrasound intensity measurement: part 1. Sensor concept and prototype calibration

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are essential to ensure the quality of diagnosis and therapy and to preserve the safety of the patient. The local temporal-average ultrasound intensity is an important output parameter as it is related to local heat production in the body. Excessive intensities may be potentially harmful in the case of diagnostic ultrasound. On the other hand, very high local intensities are needed in therapeutic applications of ultrasound, for instance for the ablation of tumors. A technique for local ultrasound intensity measurements is described in this paper. In contrast to the common methods using hydrophones, this method is based on the transformation of the ultrasound energy into heat inside an acoustic absorber and the measurement of the resulting temperature increase. The sensor concept is described and a characterization of three manufactured prototypes is given. An accompanying paper describes the application of this measurement technique to the output characterization of a typical diagnostic ultrasound machine

  6. Concentration measurement of yeast suspensions using high frequency ultrasound backscattering.

    Science.gov (United States)

    Elvira, Luis; Vera, Pedro; Cañadas, Francisco Jesús; Shukla, Shiva Kant; Montero, Francisco

    2016-01-01

    This work proposes the use of an ultrasound based technique to measure the concentration of yeasts in liquid suspension. This measurement was achieved by the detection and quantification of ultrasonic echoes backscattered by the cells. More specifically, the technique was applied to the detection and quantification of Saccharomyces cerevisiae. A theoretical approach was proposed to get the average density and sound speed of the yeasts, which were found to be 1116 kg/m(3) and 1679 m/s, respectively. These parameters were needed to model the waves backscattered by each single cell. A pulse-echo arrangement working around 50 MHz, being able to detect echoes from single yeasts was used to characterize experimentally yeast solutions from 10(2) to 10(7)cells/ml. The Non-negative Matrix Factorization denoising technique was applied for data analysis. This technique required a previous learning of the spectral patterns of the echoes reflected from yeasts in solution and the base noise from the liquid medium. Comparison between pulse correlation (without denoising) and theoretical and experimental pattern learning was made to select the best signal processing. A linear relation between ultrasound output and concentration was obtained with correlation coefficient R(2)=0.996 for the experimental learning. Concentrations from 10(4) to 10(7)cells/ml were detected above the base noise. These results show the viability of using the ultrasound backscattering technique to detect yeasts and measure their concentration in liquid cultures, improving the sensitivity obtained using spectrophotometric methods by one order of magnitude. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients.

    Science.gov (United States)

    Shin, Dong-Ho; Hong, Sung-Jin; Mintz, Gary S; Kim, Jung-Sun; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2016-11-14

    The aim of this study was to evaluate the clinical usefulness of intravascular ultrasound (IVUS)-guided new-generation drug-eluting stent (DES) implantation using a meta-analysis of individual patient-level data from randomized trials. Published randomized trials that compare IVUS-guided versus angiography-guided new-generation DES implantation are scarce. Searches of the MEDLINE, Embase, and Cochrane databases were performed to find randomized trials that compared IVUS-guided versus angiography-guided new-generation DES implantation. A total of 2,345 patients from 3 randomized trials were identified, and all patients were treated for long lesions or chronic total occlusions. Individual patient-level data were obtained. The primary endpoint was a major adverse cardiac event, a composite of cardiac death, myocardial infarction, or stent thrombosis. An intention-to-treat analysis and per protocol analysis were performed. By 1 year post-procedure, major adverse cardiac events had occurred in 0.4% of the patients who underwent IVUS-guided DES implantation versus 1.2% of those who underwent angiography-guided DES implantation (hazard ratio [HR]: 0.36; 95% confidence interval [CI]: 0.13 to 0.99; p = 0.040). For the IVUS-guided group, favorable clinical outcomes were observed for myocardial infarction (0% vs. 0.4%; HR: 0.09; p = 0.026). In addition, the clinical benefit of IVUS guidance was stronger in the per protocol analysis (HR: 0.32; 95% CI: 0.12 to 0.89; p = 0.021). Compared with angiographic guidance, IVUS-guided new-generation DES implantation was associated with favorable outcomes in terms of major adverse cardiac events, the composite of cardiac death, myocardial infarction, or stent thrombosis. These findings must be interpreted only for complex lesions, because all identified patients had long lesions or chronic total occlusions. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  9. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, Erik Feldager; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... correlated significantly (R = 0.88, P measurements. CONCLUSIONS: EUS measures portal venous flow with an acceptable correlation and agreement with TTU in anaesthetized pigs. The method is capable of monitoring the effects......BACKGROUND: Endoscopic ultrasound (EUS) is a new technique that makes it possible to measure portal venous flow when transabdominal ultrasound fails. As the technique has not been evaluated previously, we compared simultaneous measurements of portal venous flow using EUS Doppler...

  10. Logistic discriminant analysis of breast cancer using ultrasound measurement

    International Nuclear Information System (INIS)

    Abdolmaleki, P.; Mokhtari Dizaji, M.; Vahead, M.R.; Gity, M.

    2004-01-01

    Background: Logistic discriminant method was applied to differentiate malignant from benign in a group of patients with proved breast lesions of the basis of ultrasonic parameters. Materials and methods: Our database include 273 patients' ultrasonographic pictures consisting of 14 quantitative variables. The measured variables were ultrasound propagation velocity, acoustic impedance and attenuation coefficient at 10 MHz in breast lesions at 20, 25, 30 and 35 d ig c temperature, physical density and age. This database was randomly divided into the estimation of 201 and validation of 72 samples. The estimation samples were used to build the logistic discriminant model, and validation samples were used to validate the performance. Finally important criteria such as sensitivity, specificity, accuracy and area under the receiver operating characteristic curve were evaluated. Results: Our results showed that the logistic discriminant method was able to classify correctly 67 out of 72 cases presented in the validation sample. The results indicate a remarkable diagnostic accuracy of 93%. Conclusion: A logistic discriminator approach is capable of predicting the probability of malignancy of breast cancer. Features from ultrasonic measurement on ultrasound imaging is used in this approach

  11. In vitro measurement accuracy of three-dimensional ultrasound.

    Science.gov (United States)

    Zotz, R J; Trabold, T; Bock, A; Kollmann, C

    2001-02-01

    We sought to validate distance and volume measurements in three-dimensional (3-D) ultrasound images. Even with the latest equipment, it is not known how accurate 3-D echocardiographic measurements are. Six models were imaged in ethanol solution and two within a tissue phantom using a mechanical rotation device rotating in 1 degrees intervals and a real-time 3-D scanner. Distance and volume measurements (n = 60) were performed in two-dimensional (2-D) and 3-D images using TomTec and InViVo software. Distance measurements had a mean total error between 1.12% and 2.31% for Acuson (2.5 MHZ, 3 MHZ, and 4 MHZ) and Hewlett Parkard (HP) fusion frequencies h and m, HP fusion harmonic B in the axial, and between 3.5% and 4.9% in the lateral dimension. HP Harmonic A and B, Volumetrics (2.5 MHZ), and HP fusion Harmonic A exhibited significantly higher differences to reality with a mean difference between 5.1% and 8.9% in the axial and between 6.2% and 7.9% in the lateral direction. Axial 2-D measurements were not different from real dimensions except Volumetrics model 1. In the lateral axis, all imaging modalities were different from reality except the fusion harmonic modus B. Using the HP fusion frequency h and HP fusion Harmonic B-mode, volume measurements in 3-D images significantly underestimated reality, while Acuson's fundamental frequency 3.5 MHZ was not different from real volumes. Three-dimensional visualization using different ultrasound settings results in different accuracy.

  12. Automatic ultrasound technique to measure angle of progression during labor.

    Science.gov (United States)

    Conversano, F; Peccarisi, M; Pisani, P; Di Paola, M; De Marco, T; Franchini, R; Greco, A; D'Ambrogio, G; Casciaro, S

    2017-12-01

    To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r 2  = 0.98) and the low residual errors (root mean square error = 2°27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1°1' (limits of agreement, 4°29'). The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  13. Ability of combined Near-Infrared Spectroscopy-Intravascular Ultrasound (NIRS-IVUS) imaging to detect lipid core plaques and estimate cap thickness in human autopsy coronary arteries

    Science.gov (United States)

    Grainger, S. J.; Su, J. L.; Greiner, C. A.; Saybolt, M. D.; Wilensky, R. L.; Raichlen, J. S.; Madden, S. P.; Muller, J. E.

    2016-03-01

    The ability to determine plaque cap thickness during catheterization is thought to be of clinical importance for plaque vulnerability assessment. While methods to compositionally assess cap integrity are in development, a method utilizing currently available tools to measure cap thickness is highly desirable. NIRS-IVUS is a commercially available dual imaging method in current clinical use that may provide cap thickness information to the skilled reader; however, this is as yet unproven. Ten autopsy hearts (n=15 arterial segments) were scanned with the multimodality NIRS-IVUS catheter (TVC Imaging System, Infraredx, Inc.) to identify lipid core plaques (LCPs). Skilled readers made predictions of cap thickness over regions of chemogram LCP, using NIRS-IVUS. Artery segments were perfusion fixed and cut into 2 mm serial blocks. Thin sections stained with Movat's pentachrome were analyzed for cap thickness at LCP regions. Block level predictions were compared to histology, as classified by a blinded pathologist. Within 15 arterial segments, 117 chemogram blocks were found by NIRS to contain LCP. Utilizing NIRSIVUS, chemogram blocks were divided into 4 categories: thin capped fibroatheromas (TCFA), thick capped fibroatheromas (ThCFA), pathological intimal thickening (PIT)/lipid pool (no defined cap), and calcified/unable to determine cap thickness. Sensitivities/specificities for thin cap fibroatheromas, thick cap fibroatheromas, and PIT/lipid pools were 0.54/0.99, 0.68/0.88, and 0.80/0.97, respectively. The overall accuracy rate was 70.1% (including 22 blocks unable to predict, p = 0.075). In the absence of calcium, NIRS-IVUS imaging provided predictions of cap thickness over LCP with moderate accuracy. The ability of this multimodality imaging method to identify vulnerable coronary plaques requires further assessment in both larger autopsy studies, and clinical studies in patients undergoing NIRS-IVUS imaging.

  14. Intravascular "mulberry-like" bodies

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt; Klebe, J G; Henriques, U V

    1988-01-01

    Intravascular "mulberry-like" bodies in a stillborn female infant with moderate maceration are reported. The histogenesis of these structures is discussed based on light-microscopic, immunohistochemical and ultrastructural findings. No demonstrable causal relation between the intravascular lesion...... and fetal death was found, the cause of death being attributed to intrauterine asphyxia. It is concluded, that intravascular "mulberry-bodies" most likely represent artifacts due to red blood cell autolysis....

  15. Intravascular ultrasound: validation and clinical application

    NARCIS (Netherlands)

    A. van der Lugt (Aad)

    1996-01-01

    textabstractAtherogenesis is a process with an insidious onset and course. Once clinical signs and symptoms have become manifest, the obstructive lesion is usually at an advanced stage. Arteriography is the standard method for evaluation of atherosclerotic disease and has been useful in

  16. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, E F; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... echoendoscope connected to a Hitachi EUB 515-A ultrasound scanner, and by TTU with a Cardiomed CM 4000 flowmeter probe placed on the portal vein. Terlipressin, 1 mg, and placebo were administered in a blind, randomized, crossover design. Measurements were taken at base line and 30 min after each drug...

  17. Speed of Sound and Materials Thickness Measuring by Ultrasound

    Directory of Open Access Journals (Sweden)

    Carlos Dias Maciel

    2002-01-01

    Full Text Available Nowadays, ultrasound pulse-echo systems are commonly used as a diagnostic tool, due to its advantageous characteristics such as being a non-destructive analysis method and having a millimeter range resolution for the currently used frequencies. Considering these and other qualities, this study intends to develop a system for measuring and analyzing physical properties of some materials. Using a data acquisition system in a microcomputer, electrical (voltage pulses are generated to agitate a transducer that sends a pressure pulse towards the sample. This same transducer receives the echo reflected from the material, converts the mechanical energy into an electrical one, transforming it into information, which is processed later using a mathematical computer program. With this process, the values of the sound speed and the signal attenuation in the sample are obtained, plus its thickness with a minor error.

  18. Measurement of blood perfusion using photoacoustic, ultrasound, and strain imaging

    Science.gov (United States)

    Mallidi, Srivalleesha; Karpiouk, Andrei B.; Aglyamov, Salavat R.; Sethuraman, Shriram; Emelianov, Stanislav Y.

    2007-02-01

    In many clinical and research applications including cancer diagnosis, tumor response to therapy, reconstructive surgery, monitoring of transplanted tissues and organs, and quantitative evaluation of angiogenesis, sequential and quantitative assessment of microcirculation in tissue is required. In this paper we present an imaging technique capable of spatial and temporal measurements of blood perfusion through microcirculation. To demonstrate the developed imaging technique, studies were conducted using phantoms with modeled small blood vessels of various diameters positioned at different depths. A change in the magnitude of the photoacoustic signal was observed during vessel constriction and subsequent displacement of optically absorbing liquid present in the vessels. The results of the study suggest that photoacoustic, ultrasound and strain imaging could be used to sequentially monitor and qualitatively assess blood perfusion through microcirculation.

  19. COMPARISON OF PROSTATE VOLUME MEASURED BY TRANSABDOMINAL ULTRASOUND AND TRANSRECTAL ULTRASOUND IN PATIENT WITH LUTS DUE TO BENIGN PROSTATIC ENLARGEMENT

    Directory of Open Access Journals (Sweden)

    Thakappa Narayanrao Gachchi

    2017-06-01

    Full Text Available BACKGROUND A filled bladder acts as an acoustic window for transabdominal ultrasound measurements of intravesical prostatic protrusion and volume. The incidence of BPE is 18%, 29%, 40% and 56% of men in their 40s, 50s, 60s and 70s, respectively, having moderateto-severe Lower Urinary Tract Symptoms (LUTS. 1 The size of the prostate are determined by Digital Rectal Examination (DRE, Transabdominal Ultrasound and Transracial Ultrasound (TRUS. DRE tends to underestimate true prostate size as determined by transabdominal ultrasound and TRUS. The magnitude of the underestimation increases with increasing prostate size from 25% up to 50% or more. 2 TRUS volume measurements using the prostate ellipsoid volume formula (maximum width x height x length /6 are the most widely accepted measure of prostate volume. 3 Ultrasound has been increasingly used in the evaluation of patients with Benign Prostatic Enlargement (BPE. It defines prostatic size, shape and volume, which maybe correlated with the degree of bladder outlet obstruction in BPE. Ultrasound also be used to assess the effects of BPE on the upper urinary tracts and bladder. 4,5 For transabdominal ultrasound imaging of the prostate, a filled bladder is essential. It acts as an acoustic window, which readily transmits ultrasound waves and effectively serves as a conduit to the postero-caudally situated prostate. The loss of this acoustic window (an empty bladder and over distended bladder makes ultrasound imaging and measurement of prostate difficult and unreliable. 6 The aim of this study is to compare prostate volume measured by transabdominal ultrasound and by transrectal ultrasonography correlating with bladder volume. MATERIALS AND METHODS One hundred patients presenting with lower urinary tract symptoms due to benign prostatic enlargement were studied prospectively in Uroradiology Department, Institute of Nephro-Urology, Bengaluru, from May 2016 to October 2016. Inclusion Criteria- Male

  20. Quality management of nuchal translucency ultrasound measurement in Australia.

    Science.gov (United States)

    Nisbet, Debbie; Robertson, Ann; Mannil, Blessy; Pincham, Vanessa; Mclennan, Andrew

    2018-02-22

    Nuchal translucency measurement has an established role in first trimester screening. Accurate measurement requires that technical guidelines are followed. Performance can be monitored by auditing the distribution of measurements obtained in a series of cases. The primary aim is to develop an accessible, theory-based educational program for individuals whose distribution of measurements at audit falls outside an acceptable range, and assess operator performance following this intervention. Operators whose nuchal translucency measurement distributions fall outside a normal range (38-65% above the median) were expected to undergo a teleconference tutorial. Accessible from anywhere in Australia, the one hour tutorials were run by a senior sonographer (to explain technical ultrasound aspects) and the audit program manager (to explain the audit process). In 2011, 83 operators attended the teleconference tutorials. Compared to a random comparison group of operators meeting standard in 2011, teleconference tutorial attendees were significantly more likely to: (i) operate in rural or regional, rather than metropolitan, centres (P = 0.001); (ii) be less experienced (P audit cycle and was maintained over subsequent years. The mean percentage of the study cohort reaching standard over the five-year audit was 77.8% which was not statistically different from the average for the comparison cohort of all other audited operators (79.3%; P = 0.61). Teleconference tutorials are a convenient, accessible and effective way to obtain immediate and sustained improvement in operator performance. © 2018 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  1. Usefulness of bone mineral content measurement. Value of ultrasound

    International Nuclear Information System (INIS)

    Fery-Lemonnier, E.; Viens-Bitker, C.; Roux, C.; Hazebroucq, V.; Legmann, P.

    1993-01-01

    The current interest in bone mineral density measurements is related to the frequency, the morbidity and the cost of osteoporosis, which is considered to be a public health problem in developed countries. The main risk factor of osteoporotic fractures is the reduction of bone mineral density. This risk factor can be prevented by hormonal therapy in post-menopausal women. So it is of interest to develop the bone mineral density measurement methods, in osteoporotic bone areas or the entire skeleton (absorptiometry). But the interpretation of the result in term of individual fracture risk, the choice of the bone site to be examined, and the indication of the measurement are still being discussed. A new method of bone status evaluation is currently available: the broad band ultrasonic attenuation, which measures the attenuation of ultrasounds through the calcaneus bone. The device is portable, inexpensive and radiation free, and may give quantitative and qualitative assessment of bone. However, the normal values, the relation with the absorptiometry results and the contribution of this method in fracture risk evaluation are currently studied. Osteoporosis risk evaluation is an important point of health management in post-menopausal women and elderly people. Large prospective studies with the different methods are in progress

  2. Femoral anteversion measured by ultrasound and CT: a comparative study

    International Nuclear Information System (INIS)

    Aamodt, A.; Terjesen, T.; Eine, J.; Kvistad, K.A.

    1995-01-01

    Both computed tomography (CT) and ultrasonography have been used successfully to estimate the femoral anteversion (AV) angle. In this study, AV angles in 20 human adult femurs were determined by ultrasonography and CT and the measurements compared. On CT the real AV angle was measured as the angle between the head-neck centreline and the posterior condylar plane. In addition, the angle between the anterior head-trochanter (HT) tangent and the posterior condylar plane was determined. The latter angle was also measured by ultrasonography using the tilted transducer technique. The mean interobserver variation in the ultrasound measurements was 1.9 . We found ultrasonography to correlate very well with CT, both when comparing with the HT angle (r=0.95) and with the AV angle (r=0.93). The HT angle was on average 4 greater than the AV angle. In this study the accuracy of ultrasonography was ±5 and the method is recommended for screening in patients with rotational disorders of the femur. (orig.)

  3. Assessment of performance measures and learning curves for use of a virtual-reality ultrasound simulator in transvaginal ultrasound examination

    DEFF Research Database (Denmark)

    Madsen, M E; Konge, L; Nørgaard, L N

    2014-01-01

    -6), corresponding to an average of 219 min (range, 150-251 min) of training. The test/retest reliability was high, with an intraclass correlation coefficient of 0.93. CONCLUSIONS: Competence in the performance of gynecological ultrasound examination can be assessed in a valid and reliable way using virtual-reality......OBJECTIVE: To assess the validity and reliability of performance measures, develop credible performance standards and explore learning curves for a virtual-reality simulator designed for transvaginal gynecological ultrasound examination. METHODS: A group of 16 ultrasound novices, along with a group...... simulation. The novices' performance improved with practice and their learning curves plateaued at the level of expert performance, following between 3 and 4 h of simulator training....

  4. Diffuse optical tomography using semiautomated coregistered ultrasound measurements

    Science.gov (United States)

    Mostafa, Atahar; Vavadi, Hamed; Uddin, K. M. Shihab; Zhu, Quing

    2017-12-01

    Diffuse optical tomography (DOT) has demonstrated huge potential in breast cancer diagnosis and treatment monitoring. DOT image reconstruction guided by ultrasound (US) improves the diffused light localization and lesion reconstruction accuracy. However, DOT reconstruction depends on tumor geometry provided by coregistered US. Experienced operators can manually measure these lesion parameters; however, training and measurement time are needed. The wide clinical use of this technique depends on its robustness and faster imaging reconstruction capability. This article introduces a semiautomated procedure that automatically extracts lesion information from US images and incorporates it into the optical reconstruction. An adaptive threshold-based image segmentation is used to obtain tumor boundaries. For some US images, posterior shadow can extend to the chest wall and make the detection of deeper lesion boundary difficult. This problem can be solved using a Hough transform. The proposed procedure was validated from data of 20 patients. Optical reconstruction results using the proposed procedure were compared with those reconstructed using extracted tumor information from an experienced user. Mean optical absorption obtained from manual measurement was 0.21±0.06 cm-1 for malignant and 0.12±0.06 cm-1 for benign cases, whereas for the proposed method it was 0.24±0.08 cm-1 and 0.12±0.05 cm-1, respectively.

  5. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, Joanna M. [Division of Clinical Neurosciences, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom)]. E-mail: jmw@skull.dcn.ed.ac.uk; Lewis, Steff [Division of Clinical Neurosciences, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom)

    2005-11-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone.

  6. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    International Nuclear Information System (INIS)

    Wardlaw, Joanna M.; Lewis, Steff

    2005-01-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone

  7. Measurement of a PAGAT gel dosimeter by ultrasound computed tomography

    Science.gov (United States)

    Khoei, S.; Trapp, J. V.; Langton, C. M.

    2013-06-01

    In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.

  8. Education and Propagation of Intravascular Surgery in Okinawa

    Science.gov (United States)

    Harakuni, T.; Hyodo, A.; Shingaki, T.; Kugai, M.; Kinjyo, T.; Kinjyo, T.; Tsuchida, H.; Sugimoto, K.; Yoshii, Y.

    2004-01-01

    Summary Okinawa is an island located on the southwest edge of the Japanese Islands in which about 1,300,000 people live, and is an area where self-conclusion type medical treatment is desired. In this area, intravascular surgery was only performed for several cases per year until 1998. From May 1999, intravascular surgery started being performed in earnest, and 140 or more cases of intravascular surgery per year were performed in 2002. In the meantime, various measures for the propagation and development of intravascular surgery that we undertook led to the increase in the number of cases. As a result, the choice of medical treatment has increased by propagating these medical treatments, and it seems that this has contributed to the welfare of the people of Okinawa. PMID:20587285

  9. [Ultrasound measurement of calcaneus: a promising method for prediction of osteoporotic fractures

    NARCIS (Netherlands)

    Bergh, J.P.W. van den; Smals, A.G.H.; Schweitzer, D.H.; Hermus, A.R.M.M.

    2001-01-01

    When carrying out quantitative ultrasound (QUS) measurements of the calcaneus, broadband ultrasound attenuation (BUA, in dB/MHz) and speed of sound (SOS, in m/s) are assessed. From in vitro studies it is known that the mechanical properties of trabecular bone (stiffness and strength) can be better

  10. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network.

    Science.gov (United States)

    Xing, Jida; Chen, Jie

    2015-06-23

    In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous

  11. Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Min Xu

    2015-07-01

    Full Text Available AIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD, and evaluate the difference and consistency.METHODS:Fifty-eight cases(98 eyeswith age-related cataract during July to October in 2013 did the A-scan ultrasound with contact and immersion measurements and IOL Master to get the results of ACD. Difference in measurements between methods was assessed using the variance analysisi. Consistency was assessed using Bland-Altman.RESULTS: The ACD measured by IOL Master was 2.31~3.90mm, the mean was 3.03±0.38mm. The ACD measured by contact A-scan ultrasound was 1.51~4.06mm, the mean was 2.88±0.56mm. The ACD measured by immersion A-scan ultrasound was 1.99~4.17mm, the mean was 3.17±0.38mm. The results of IOL Master and contact A-scan ultrasound had statistical differences(P=0.022P=0.031P=0.000CONCLUSION: The rank of ACD of patients with cataract is immersion A-scan ultrasound, IOL Master and contact A-scan ultrasound. The consistency is poor, and the three methods can't be interchanged clinically.

  12. Disseminated intravascular coagulation in sepsis

    NARCIS (Netherlands)

    Zeerleder, Sacha; Hack, C. Erik; Wuillemin, Walter A.

    2005-01-01

    Disseminated intravascular coagulation is a frequent complication of sepsis. Coagulation activation, inhibition of fibrinolysis, and consumption of coagulation inhibitors lead to a procoagulant state resulting in inadequate fibrin removal and fibrin deposition in the microvasculature. As a

  13. Assessment of performance measures and learning curves for use of a virtual-reality ultrasound simulator in transvaginal ultrasound examination.

    Science.gov (United States)

    Madsen, M E; Konge, L; Nørgaard, L N; Tabor, A; Ringsted, C; Klemmensen, A K; Ottesen, B; Tolsgaard, M G

    2014-12-01

    To assess the validity and reliability of performance measures, develop credible performance standards and explore learning curves for a virtual-reality simulator designed for transvaginal gynecological ultrasound examination. A group of 16 ultrasound novices, along with a group of 12 obstetrics/gynecology (Ob/Gyn) consultants, were included in this experimental study. The first two performances of the two groups on seven selected modules on a high-fidelity ultrasound simulator were used to identify valid and reliable metrics. Performance standards were determined and novices were instructed to continue practicing until they attained the performance level of an expert subgroup (n = 4). All 28 participants completed the selected modules twice and all novices reached the expert performance level. Of 153 metrics, 48 were able to be used to discriminate between the two groups' performance. The ultrasound novices scored a median of 43.8% (range, 17.9-68.9%) and the Ob/Gyn consultants scored a median of 82.8% (range, 60.4-91.7%) of the maximum sum score (P virtual-reality simulation. The novices' performance improved with practice and their learning curves plateaued at the level of expert performance, following between 3 and 4 h of simulator training. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  14. Measurement of muscle architecture concurrently with muscle hardness using ultrasound strain elastography.

    Science.gov (United States)

    Chino, Kentaro; Akagi, Ryota; Dohi, Michiko; Takahashi, Hideyuki

    2014-09-01

    The B-mode ultrasound image that can measure muscle architecture is displayed side by side with the ultrasound strain elastogram that can assess muscle hardness. Consequently, muscle architecture can be measured concurrently with muscle hardness using ultrasound strain elastography. To demonstrate the measurement of muscle architecture concurrently with muscle hardness using ultrasound strain elastography. Concurrent measurements of muscle architectural parameters (muscle thickness, pennation angle, and fascicle length) and muscle hardness of the medial gastrocnemius were performed with ultrasound strain elastography. Separate measurements of the muscle architectural parameters were also performed for use as reference values for the concurrent measurements. Both types of measurements were performed twice at 20° dorsiflexion, neutral position, and 30° plantar flexion. Coefficients of variance of the muscle architectural parameters obtained from the concurrent measurements (≤7.6%) were significantly higher than those obtained from the separate measurements (≤2.4%) (all P  0.05). The use of ultrasound strain elastography for the concurrent measurement of muscle architecture and muscle hardness is feasible. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

    Directory of Open Access Journals (Sweden)

    Jorge J

    2013-02-01

    Full Text Available J Jorge,1 JL Rosado,2 JA Díaz-Rey,1 JM González-Méijome11Clinical and Experimental Optometry Research Laboratory, Center of Physics (Optometry, School of Sciences, University of Minho, Braga, 2Opticlinic, Lisboa, PortugalBackground: The purpose of this study was to compare the accuracy of the new Sirius® Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT and anterior chamber depth (ACD with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively.Methods: CCT and ACD was measured in 50 right eyes from 50 healthy subjects using a Sirius Scheimpflug camera, SP100 ultrasound pachymetry, and US800 ultrasound biometry.Results: CCT measured with the Sirius was 546 ± 39 µm and 541 ± 35 µm with SP100 ultrasound pachymetry (P = 0.003. The difference was statistically significant (mean difference 4.68 ± 10.5 µm; limits of agreement −15.8 to 25.20 µm. ACD measured with the Sirius was 2.96 ± 0.3 mm compared with 3.36 ± 0.29 mm using US800 ultrasound biometry (P < 0.001. The difference was statistically significant (mean difference −0.40 ± 0.16 mm; limits of agreement −0.72 to 0.07 mm. When the ACD values obtained using ultrasound biometry were corrected according to the values for CCT measured by ultrasound, the agreement increased significantly between both technologies for ACD measurements (mean difference 0.15 ± 0.16 mm; limits of agreement −0.16 to 0.45 mm.Conclusion: CCT and ACD measured by Sirius and ultrasound methods showing good agreement between repeated measurements obtained in the same subjects (repeatability with either instrument. However, CCT and ACD values, even after correcting ultrasound ACD by subtracting the CCT value obtained with either technology should not be used interchangeably.Keywords: Scheimpflug corneal tomography, ultrasound biometry, ultrasound pachymetry, limits of agreement

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  17. Ultrasound thrombolysis in stent thrombosis.

    Science.gov (United States)

    Rassin, T; Desmet, W; Piessens, J; Rosenschein, U

    2000-11-01

    Recent refinement in stent implantation technique and peri-procedural pharmacological treatment has lowered the incidence of stent thrombosis significantly. Still, all stent thromboses are associated with major adverse events. In previous studies it has been suggested that intravascular ultrasound fibrinolysis is safe and effective. In this report, ultrasound successfully reperfused thrombotically occluded stents. These observations suggest that ultrasound may dissolve occlusive platelet-rich thrombus effectively and safely. Cathet. Cardiovasc. Intervent. 51:332-334, 2000. Copyright 2000 Wiley-Liss, Inc.

  18. An automated in vitro model for the evaluation of ultrasound modalities measuring myocardial deformation

    Directory of Open Access Journals (Sweden)

    Stigö Albin

    2010-09-01

    Full Text Available Abstract Background Echocardiography is the method of choice when one wishes to examine myocardial function. Qualitative assessment of the 2D grey scale images obtained is subjective, and objective methods are required. Speckle Tracking Ultrasound is an emerging technology, offering an objective mean of quantifying left ventricular wall motion. However, before a new ultrasound technology can be adopted in the clinic, accuracy and reproducibility needs to be investigated. Aim It was hypothesized that the collection of ultrasound sample data from an in vitro model could be automated. The aim was to optimize an in vitro model to allow for efficient collection of sample data. Material & Methods A tissue-mimicking phantom was made from water, gelatin powder, psyllium fibers and a preservative. Sonomicrometry crystals were molded into the phantom. The solid phantom was mounted in a stable stand and cyclically compressed. Peak strain was then measured by Speckle Tracking Ultrasound and sonomicrometry. Results We succeeded in automating the acquisition and analysis of sample data. Sample data was collected at a rate of 200 measurement pairs in 30 minutes. We found good agreement between Speckle Tracking Ultrasound and sonomicrometry in the in vitro model. Best agreement was 0.83 ± 0.70%. Worst agreement was -1.13 ± 6.46%. Conclusions It has been shown possible to automate a model that can be used for evaluating the in vitro accuracy and precision of ultrasound modalities measuring deformation. Sonomicrometry and Speckle Tracking Ultrasound had acceptable agreement.

  19. Non-invasive measurement of pressure gradients using ultrasound

    DEFF Research Database (Denmark)

    Olesen, Jacob Bjerring; Traberg, Marie Sand; Pihl, Michael Johannes

    2013-01-01

    A non-invasive method for estimating 2-D pressure gradients from ultrasound vector velocity data is presented. The method relies on in-plane vector velocity fields acquired using the Transverse Oscillation method. The pressure gradients are estimated by applying the Navier-Stokes equations...

  20. Predicting beef carcass retail products of Mediterranean buffaloes by real-time ultrasound measures

    Directory of Open Access Journals (Sweden)

    R. De Castro Mourão

    2010-02-01

    Full Text Available Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU, slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT. Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW, rib eye area (REAU and subcutaneous fat thickness (FTU between 12th and 13 th ribs and also over the biceps femoris muscle (FTP8 by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  2. Ultrasound and histological measurements of dividing membrane thickness in twin gestations.

    Science.gov (United States)

    Bracero, L A; Huff, C; Blitz, M J; Plata, M J; Seybold, D J; Broce, M

    2017-10-01

    To determine how prenatal ultrasound measurements of dividing membrane thickness correlate with postnatal histological measurements and chorionicity in twin gestations. This was a prospective, longitudinal cohort study of twin gestations. Dividing membrane thickness was measured by transabdominal ultrasound, with the insonation beam both parallel and perpendicular to the membrane, in the second or third trimester, depending on when care was established. Ultrasound examinations were performed every 4 weeks following initial assessment until delivery. Measurements of membrane thickness from the first ultrasound examination were compared with histological measurements after delivery. A total of 45 twin pregnancies (32 dichorionic, 13 monochorionic) were included. Mean gestational age at initial ultrasound examination was 24.1 ± 7.3 weeks. Parallel ultrasound measurements of membrane thickness were 1.6 ± 0.8 mm for monochorionic and 2.5 ± 0.9 mm for dichorionic gestations (P = 0.001). Perpendicular ultrasound measurements were 1.6 ± 0.3 mm for monochorionic and 2.2 ± 0.8 mm for dichorionic gestations (P = 0.009). Inter- and intraobserver reliability of ultrasound measurements were 0.847 and 0.950, respectively. Parallel and perpendicular ultrasound measurements correlated better with each other (R = 0.807, P membrane thickness (R parallel  = 0.538, P Receiver-operating characteristics curve analyses to predict histological membrane thickness > 50 th percentile resulted in an area under the curve (AUC) of 0.828 for parallel (P membrane thickness is positively correlated with postnatal histological measurement. Dichorionicity can be determined by a magnified dividing membrane thickness ≥ 1.9 mm. Measurements with the ultrasound beam parallel to the dividing membrane may be more accurate than perpendicular measurements. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016

  3. Increased liver weights in severely burned children: comparison of ultrasound and autopsy measurements.

    Science.gov (United States)

    Barrow, R E; Mlcak, R; Barrow, L N; Hawkins, H K

    2004-09-01

    Hepatomegaly is a common finding at autopsy in severely burned children surviving less than 6 months. This study validates a reliable ultrasound method which can be used to identify changes in liver size in severely burned children during acute hospitalization. Thirty-eight children, age 0.5-17 years with burns covering over 40% of their total surface area were studied at autopsy. Liver weight was measured at autopsy and compared to predicted liver weight for age and height. Eighteen had liver size measured by ultrasound within 10 days of death while five had ultrasound liver measures after death just prior to autopsy. All burned children who survived 7 days or more (n = 33) had liver weights at autopsy that were greater than predicted for age and height while all 23 livers measured by ultrasound were greater than predicted. Autopsy weights correlated well with weights estimated by ultrasound, R = 0.824. At autopsy, those who survived 7 days or more had enlarged livers ranging from 142 to 406% of their predicted normal age and height. Common histologic findings include large and small-droplet fat deposits, and cholestasis. The degree of these histologic abnormalities correlated with the increase in liver weight, R = 0.652. Ultrasound is a valid, noninvasive method for measuring liver weight changes in severely burned children during acute hospitalization. Ninety-five percent of the severely burned children from this institute had significant hepatomegaly identified at autopsy.

  4. Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure.

    Science.gov (United States)

    Joensen, J B; Juul, S; Abrahamsen, J; Henneberg, E W; Lindholt, Jes S

    2008-01-01

    This study assesses measurement variation in the measurement of ankle systolic blood pressure (ABP) when measured with Doppler ultrasound and with the strain gauge method. Ninety-seven patients were included. ABP was measured with Doppler ultrasound and with the strain gauge method. The methods were compared graphically by scatterplots and analyzed by paired t test, analysis of variance, and Pitman's paired variance ratio test. ABP was measured by strain gauge in all extremities, whereas no Doppler signal was obtainable in 7 limbs (4%). There was no systematic difference in measurements between the means of the two measurements. However, a substantial difference of more than 25 mm Hg was found in 15% of limbs and more than 20 mm Hg in 20%. In the majority of patients, measurements of ABP by Doppler ultrasound and the strain gauge method give similar results, but for a minority the discrepancy is substantial.

  5. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  6. Fracture status in men assessed by quantitative ultrasound measurements at the calcaneus.

    Science.gov (United States)

    Pluskiewicz, Wojciech; Wilk, Robert; Wielgórecki, Artur; Golba, Krzysztof S; Drozdzowska, Bogna

    2011-07-01

    The aim of the study was to assess fracture status in men by quantitative ultrasound measurements at the calcaneus. The diagnostic accuracy of quantitative ultrasound measurements was evaluated at baseline and follow-up. We observed 165 men (baseline age ± SD, 59.84 ± 10.6 years) recruited from an outpatient osteoporosis clinic. The mean follow-up duration was approximately 101.3 ± 35 months. There was no difference in either age or body mass index at baseline between the patients with a fracture history (n = 30) and the others (n = 135). The following fractures were identified at baseline: ankle, 15; wrist, 10; rib, 9; foot, 5; and hip, 1. The speed of sound (meters per second), broadband ultrasound attenuation (decibels per megahertz), and stiffness index (percent) were measured with a quantitative ultrasound device. The date of fracture occurrence at follow-up was defined as the final point. In the patients with a fracture history, the ultrasound variables were significantly lower than those in the rest of the group (P fractures occurred in 21 patients (wrist, 11; ankle, 5; rib, 3; hip, 1; and humerus, 1), and the ultrasound outcomes were nonsignificantly lower in the fractured men. The risk of fracture was estimated by the Cox regression analysis. A prior fracture was the only factor that significantly (4 times) increased the risk of a subsequent fracture (hazard ratio, 4.21; 95% confidence interval, 1.81-9.86; P Calcaneus ultrasound measurements can distinguish between patients with fractures and those without. In follow-up, ultrasound measurements did not indicate an increased fracture risk; a prior osteoporotic fracture was the major prognostic factor.

  7. Intravascular photoacoustic tomography for characterization of atherosclerotic lipid and inflammation

    Science.gov (United States)

    Zhang, Jian; Qin, Huan; Shi, Yujiao; Yang, Sihua; Xing, Da

    2014-09-01

    Photoacoustic imaging is a fast growing imaging technology depending on its high optical resolution of optics while taking the advantage of the high penetration depth of ultrasound. In this paper, we demonstrate the new progress in the photoacoustic imaging. Atherosclerosis is characterized by a progressive build-up of lipid in the arterial wall, which is known as plaque. Histological studies demonstrate that the primary cause of acute cardiovascular events is the rupture of atherosclerotic plaques. Lipid and inflammation within the plaque are related to influence the propensity of plaques to disrupt. Photoacoustic intravascular tomography (IVPAT) holds a great advantage in providing comprehensive morphological and functional information of plaques. Lipid relative concentration maps of atherosclerotic aorta were obtained and compared with histology. Furthermore, by selectively targeting the intravascular inflammatory cytokines, IVPAT is also capable of mapping the inflamed area and determining the degree of inflammation.

  8. Intravascular blood coagulation after irradiation

    International Nuclear Information System (INIS)

    Sushkevich, G.N.

    1981-01-01

    The problems of activation of intravascular blood coagulation (JVBC) at different stages after irradiation, are considered. JVBC peculiarities (disseminated intravascular syndrome (DIV) or thrombo hemorrhagic syndrome) are investigated. Literature on alterations which take place in the organism under effect of ionizing irradiation is analyzed. This analysis proves the characteristic features of thrombinogenesis activation and development of DIV syndrome not only in the early post-radiation period, but in the middle of radiation disease, as well. It is also shown that ionizing radiation activizes the hemocoagulation process and causes IVBC in the case of both local and general irradiation [ru

  9. Volume of preclinical xenograft tumors is more accurately assessed by ultrasound imaging than manual caliper measurements.

    Science.gov (United States)

    Ayers, Gregory D; McKinley, Eliot T; Zhao, Ping; Fritz, Jordan M; Metry, Rebecca E; Deal, Brenton C; Adlerz, Katrina M; Coffey, Robert J; Manning, H Charles

    2010-06-01

    The volume of subcutaneous xenograft tumors is an important metric of disease progression and response to therapy in preclinical drug development. Noninvasive imaging technologies suitable for measuring xenograft volume are increasingly available, yet manual calipers, which are susceptible to inaccuracy and bias, are routinely used. The goal of this study was to quantify and compare the accuracy, precision, and inter-rater variability of xenograft tumor volume assessment by caliper measurements and ultrasound imaging. Subcutaneous xenograft tumors derived from human colorectal cancer cell lines (DLD1 and SW620) were generated in athymic nude mice. Experienced independent reviewers segmented 3-dimensional ultrasound data sets and collected manual caliper measurements resulting in tumor volumes. Imaging- and caliper-derived volumes were compared with the tumor mass, the reference standard, determined after resection. Bias, precision, and inter-rater differences were estimated for each mouse among reviewers. Bootstrapping was used to estimate mean and confidence intervals of variance components, intraclass correlation coefficients (ICCs), and confidence intervals for each source of variation. The average deviation from the true volume and inter-rater differences were significantly lower for ultrasound volumes compared with caliper volumes (P = .0005 and .001, respectively). Reviewer ICCs for ultrasound and caliper measurements were similarly low (1%), yet caliper volume variance was 1.3-fold higher than for ultrasound. Ultrasound imaging more accurately, precisely, and reproducibly reflects xenograft tumor volume than caliper measurements. These data suggest that preclinical studies using the xenograft burden as a surrogate end point measured by ultrasound imaging require up to 30% fewer animals to reach statistical significance compared with analogous studies using caliper measurements.

  10. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  11. Predicting the difficulty of operative vaginal delivery by ultrasound measurement of fetal head station.

    Science.gov (United States)

    Kasbaoui, Sidi; Séverac, François; Aïssi, Germain; Gaudineau, Adrien; Lecointre, Lise; Akladios, Chérif; Favre, Romain; Langer, Bruno; Sananès, Nicolas

    2017-05-01

    Clinical assessment of fetal head station is difficult and subjective; it is mandatory before attempting operative vaginal delivery. The principal objective of our study was to assess whether measurement of the perineum-to-skull ultrasound distance was predictive of a difficult operative vaginal delivery. Secondary objectives included evaluation of the interobserver reproducibility of perineum-to-skull ultrasound distance and comparison of this measurement and digital examination in predicting a difficult operative delivery. This was a prospective cohort study including all cases of operative vaginal deliveries in singleton pregnancies in cephalic presentation >34 weeks' gestation, from 2012 through 2015. All data were entered prospectively in a medical record system specially devised to meet the requirements of this study. Of the 659 patients in whom perineum-to-skull ultrasound distance was measured prior to operative vaginal delivery, 120 (18%) met the composite criterion for a difficult extraction. Perineum-to-skull ultrasound distance measurement of ≥40 mm was significantly associated with the occurrence of a difficult extraction based on the composite criterion, after adjustment for parity, presentation type, and fetal macrosomia (odds ratio, 2.38; 95% confidence interval, 1.51-3.74; P = .0002). The intraclass correlation coefficient between the perineum-to-skull ultrasound distance measured by the first operator and that measured by the second operator was 0.96 (95% confidence interval, 0.95-0.97; P Measurement of the perineum-fetal skull ultrasound distance is a reproducible and predictive index of the difficulty of instrumental extraction. Ultrasound is a useful supplementary tool to the usual clinical findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  13. Genetic Analysis of Ultrasound and Carcass Measurement Traits in a Regional Hanwoo Steer Population

    Directory of Open Access Journals (Sweden)

    Jeong Mi Hwang

    2014-04-01

    Full Text Available Ultrasound measurements of backfat thickness (UBF, longissimus muscle area (ULMA and marbling score (UMS and carcass measurements of carcass weight (CW, backfat thickness (BF, longissimus muscle area (LMA, and marbling score (MS on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS, the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.

  14. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Jida Xing

    2015-06-01

    Full Text Available In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared

  15. Comparison of corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and digital caliper in frozen canine corneas.

    Science.gov (United States)

    Jeong, Seowoo; Kang, Seonmi; Park, Sangwan; Park, Eunjin; Lim, Jaegook; Nam, Taekjin; Seo, Kangmoon

    2017-11-07

    To evaluate the clinical efficacy among ultrasound pachymetry (UP), ultrasound biomicroscopy (UBM), and manual measurement (MM) with digital caliper by comparing corneal thickness (COT) values obtained from frozen canine corneas ex vivo. COT was measured using UP, UBM, and MM in eight enucleated normal canine eyes frozen at -20 °C for 4 weeks. After thawing at room temperature for 2 h, the COT values were obtained from five sites on each cornea: central corneal thickness (CCOT), thickness at the 3, 6, 9, and 12 o'clock positions (3COT, 6COT, 9COT, and 12COT, respectively). For each device, measurements were performed three times at each designated site by one operator. Intraclass correlation coefficient, repeated-measures analysis of variance, and Bland-Altman plot were performed for statistical analyses. The mean CCOT was 839.0 ± 138.2, 857.6 ± 127.9, and 849.1 ± 132.8 μm for UP, UBM, and MM, respectively. There was no statistically significant difference among the measurements by all three devices (P > 0.05). The statistical agreement among these devices was also shown to be good according to Bland-Altman plots. In addition, the values measured on the peripheral sites of the cornea (3COT, 6COT, 9COT, and 12COT) also revealed no significant differences among the three devices. The difference between CCOT and peripheral corneal thickness was also statistically insignificant. The UP, UBM, and MM measurements showed statistically similar COT values. The UBM and UP provided accurate and reliable measurements comparable to MM and could be used effectively for clinical COT measurements. © 2017 American College of Veterinary Ophthalmologists.

  16. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  17. Intravascular bronchio-alveolar tumor

    International Nuclear Information System (INIS)

    Mata, J.M.; Caceres, J.; Prat, J.; Lopez, J.I.; Velilla, O.

    1991-01-01

    In 1975 Dail and Liebow described the clinical and pathological characteristics of a pulmonary tumor which they dominated intravascular bronchio-alveolar tumor (IVBAT). Our aim is to acquaint radiologists with the existence of this tumor by describing the radiologic findings in 2 patients with IVBAT, 1 with hepatic involvement ant the other with pulmonary osteoarthropathy. (author). 7 refs.; 2 figs

  18. Measurement of abdominal muscle thickness using M-mode ultrasound imaging during functional activities.

    Science.gov (United States)

    Bunce, Steve M; Hough, Alan D; Moore, Ann P

    2004-02-01

    Ultrasound imaging has been previously utilized in the measurement of muscle thickness and cross-sectional area in research studies, and advocated as a clinical biofeedback tool in the rehabilitation of transversus abdominis function following episodes of low back pain. This paper describes how the thickness of the abdominal muscles can be quantified with a new measurement technique using M-mode ultrasound. The technique uses a custom-made transducer holder that facilitates measurement of muscle thickness changes during functional activity. Limitations of the technique and potential future applications are discussed. The M-mode ultrasound technique may provide an effective method for the non-invasive measurement of abdominal muscle thickness during functional activities.

  19. How to Measure Size of Tubal Ectopic Pregnancy on Ultrasound Scan?

    Science.gov (United States)

    Rajah, K; Goodhart, V; Zamora, K P; Amin, T; Jauniaux, E; Jurkovic, D

    2017-11-16

    To identify the preoperative ultrasound measurements for assessing the size of tubal ectopic pregnancy which correlate best with the findings at surgery. We conducted a prospective study of all women with a conclusive transvaginal ultrasound diagnosis of tubal ectopic pregnancy over a 10-month period. In each case, we measured the total size of the ectopic pregnancy by placing the calipers on the outer edges of the visible trophoblastic tissue. In ectopic pregnancies, presenting with a well-defined gestational sac we also measured the size of coelomic (chorionic) cavity using the inner borders of the trophoblastic ring as the reference points. In women with signs of intraabdominal bleeding, we measured the size of the haematosalpinx and haemoperitoneum. The surgeons were blinded to the ultrasound measurements and they were asked to estimate the size of the ectopic pregnancy and the amount of haemoperitoneum intraoperatively. A total of 105 women were diagnosed with a tubal ectopic pregnancy on ultrasound examination out of which 71/105 (67.6%) were managed surgically. We found a significant (pectopic pregnancy as reported during surgery. In the absence of a haematosalpinx, the mean total outer diameter of ectopic pregnancy had the highest positive correlation with the size of tubal ectopic at surgery (r=0.65, Pectopic pregnancy at surgery. There was a significant (pectopic pregnancy on ultrasound correlate better with the surgical findings than the size of coelomic cavity. Our findings show that the standard approach to measure the size of intrauterine pregnancy on ultrasound should be adapted in women diagnosed with tubal ectopic pregnancies to include these additional measurements. This article is protected by copyright. All rights reserved.

  20. Brachytherapy optimal planning with application to intravascular radiation therapy

    DEFF Research Database (Denmark)

    Sadegh, Payman; Mourtada, Firas A.; Taylor, Russell H.

    1999-01-01

    . Dose rate calculations are based on the sosimetry formulation of the American Association of Physicists in Medicine, Task Group 43. We apply the technique to optimal planning for intravascular brachytherapy of intimal hyperplasia using ultrasound data and 192Ir seeds. The planning includes...... determination of an optimal dwell-time sequence for a train of seeds that deliver ratiation while stepping through the vessel lesion. The results illustrate the advantage of this strategy over the common approach of delivering radiation by positioning a single train of seeds along the whole lesion....

  1. Feasibility of Quantitative Ultrasound Measurement of the Heel Bone in People with Intellectual Disabilities

    Science.gov (United States)

    Mergler, S.; Lobker, B.; Evenhuis, H. M.; Penning, C.

    2010-01-01

    Low bone mineral density (BMD) and fractures are common in people with intellectual disabilities (ID). Reduced mobility in case of motor impairment and the use of anti-epileptic drugs contribute to the development of low BMD. Quantitative ultrasound (QUS) measurement of the heel bone is a non-invasive and radiation-free method for measuring bone…

  2. Visualizing and measuring the temperature field produced by medical diagnostic ultrasound using thermography

    International Nuclear Information System (INIS)

    Vachutka, J; Grec, P; Mornstein, V; Caruana, C J

    2008-01-01

    The heating of tissues by diagnostic ultrasound can pose a significant hazard particularly in the imaging of the unborn child. The demonstration of the temperature field in tissue is therefore an important objective in the teaching of biomedical physics to healthcare professionals. The temperature field in a soft tissue model was made visible and measured using thermography. Temperature data from the images were used to investigate the dependence of temperature increase within the model on ultrasound exposure time and distance from the transducer. The experiment will be used within a multi-professional biomedical physics teaching laboratory for enhancing learning regarding the principles of thermography and the thermal effects of ultrasound to medical and healthcare students and also for demonstrating the quantitative use of thermographic imaging to students of biophysics, medical physics and medical technology

  3. STEREOCHEMICAL ASPECTS OF HYDRATION OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS .3. DENSITY AND ULTRASOUND MEASUREMENTS

    NARCIS (Netherlands)

    GALEMA, SA; HOILAND, H

    1991-01-01

    Density and ultrasound measurements have been performed in aqueous solutions of pentoses, hexoses, methylpyranosides, and disaccharides as a function of molality of carbohydrate (0-0.3 mol kg-1). Partial molar volumes, partial molar isentropic compressibilities, and hydration numbers have been

  4. An ultrasound mini-balance for measurement of therapy level ultrasound

    International Nuclear Information System (INIS)

    Sutton, Yvonne; McBride, Karne; Pye, Stephen

    2006-01-01

    This paper describes a cost-effective method for measuring acoustic power using a radiation force balance. The device is based around a long established balance design with a gantry arrangement fitted with an absorbing target. The notion of this balance design is that it can easily be constructed from materials that would be readily available within a clinical or industrial environment. The mini-balance was calibrated using a transfer standard against an NPL Reference balance, so a comparison of the performance between the two systems could be assessed. The measurements were completed at 1 MHz and 3 MHz and over the acoustic power range of 1 W to 15 W. The results show the acoustic power measured on the mini-balance to be within 5% of the reference measurements made on the NPL Balance. A separate systematic uncertainty budget is also presented based on studies made on the balance and on similar systems. The overall expanded uncertainty was calculated to be within 14% at 1 W level, decreasing with increasing power level to 7.4% above 5 W

  5. An Improved Tumour Temperature Measurement and Control Method for Superficial Tumour Ultrasound Hyperthermia Therapeutic System

    Energy Technology Data Exchange (ETDEWEB)

    Shen, G F; Chen, Y Z; Ren, G X [Biomedical Instrument Institute, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2006-10-15

    In tumour hyperthermia therapy, the research on measurement and control of tumour temperature is very important. Based on the hardware platform of superficial tumour ultrasound hyperthermia therapeutic system, an improved tumour temperature measurement and control method is presented in this paper. The experiment process, data and results are discussed in detail. The improved method will greatly reduce the pain and dread of the patients during the therapy period on the tumour temperature measurement and control by using the pinhead sensor.

  6. Inferior Vena Cava Measurement With Ultrasound: What is The Best View and Best Mode?

    Directory of Open Access Journals (Sweden)

    Nathan M. Finnerty

    2017-04-01

    Full Text Available Introduction: Intravascular volume status is an important clinical consideration in the management of the critically ill. Point-of-care ultrasonography (POCUS has gained popularity as a non-invasive means of intravascular volume assessment via examination of the inferior vena cava (IVC. However, there are limited data comparing different acquisition techniques for IVC measurement by POCUS. The goal of this evaluation was to determine the reliability of three IVC acquisition techniques for volume assessment: subxiphoid transabdominal long axis (LA, transabdominal short axis (SA, and right lateral transabdominal coronal long axis (CLA (aka “rescue view”. Methods: Volunteers were evaluated by three experienced emergency physician sonographers (EP. Gray scale (B-mode and motion-mode (M-mode diameters were measured and IVC collapsibility index (IVCCI calculated for three anatomic views (LA, SA, CLA. For each IVC measurement, we calculated descriptive statistics, intra-class correlation coefficients (ICC, and two-way univariate analyses of variance. Results: EPs evaluated 39 volunteers, yielding 351 total US measurements. Measurements of the three views had similar means (LA 1.9 ± 0.4cm; SA 1.9 ± 0.4cm; CLA 2.0 ± 0.5cm. For B-Mode, LA had the highest ICC (0.86, 95% CI [0.76-0.92] while CLA had the poorest ICC (0.74, 95% CI [0.56-0.85]. ICCs for all M-mode IVCCI were low. Significant interaction effects between anatomical view and EP were observed for B-mode and M-mode measurements. Post-hoc analyses revealed difficulty in consistent view acquisition between EPs. Conclusion: Inter-rater reliability of the IVC by EPs was highest for B-mode LA and poorest for all M-Mode IVC collapsibility indices (IVCCI. These results suggest that B-mode LA holds the most promise to deliver reliable measures of IVC diameter. Future studies may focus on validation in a clinical setting as well as comparison to a reference standard. [West J Emerg Med. 2017;18(3496-501.

  7. Discriminative and reliability analyses of ultrasound measurement of abdominal muscles recruitment.

    Science.gov (United States)

    Ferreira, Paulo H; Ferreira, Manuela L; Nascimento, Dafne P; Pinto, Rafael Z; Franco, Marcia R; Hodges, Paul W

    2011-10-01

    Rehabilitative ultrasound imaging has a great potential to be used as a tool in the assessment of trunk muscle function in patients with low back pain (LBP). However, a further investigation of the discriminative ability of this tool as well as the effect of operators' levels of training on reliability is warranted. Discriminative analysis of ultrasound and electromyography (EMG) measurements of transversus abdominus (TrA), obliquus internus (OI), and obliquus externus (OE) muscles function between people with and without LBP and the effect of operator's training on reliability of TrA muscle function of chronic LBP patients were conducted. For the discriminative study, measurements were collected from 10 subjects with LBP and 10 matched controls during isometric low load tasks with their limbs suspended. For the reliability study, in stage 1 the reliability of single ultrasonographic static images involved 4 operators (1 trained and 3 non-trained), whereas, in stage 2, two operators (1 trained and 1 non-trained) were used to determine the reliability of TrA thickness change. Methods used in the statistical analysis were pearson correlation and receiver operating characteristic curve for the discriminative study and intraclass correlation coefficient (ICC) for the reliability study. While ultrasound measures of OE muscle function showed poor association with EMG (r = 0.28, p = 0.22), TrA and OI function showed moderate to excellent association (TrA: r = 0.74, p Ultrasound and EMG measures of TrA and OI function discriminated LBP patients from controls. Reliability of the assessment of TrA function with a trained operator (ICC = 0.92; 95% CI: 0.81-0.97) was substantially higher than a non-trained one (ICC = 0.44; 95% CI: -0.41-0.78). In conclusion, ultrasound measures of deep trunk function is a valid discriminative tool in LBP but highly dependent on operator's level of training. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Dynamic measurement of pennation angle of gastrocnemius muscles during contractions based on ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Zhou Yongjin

    2012-09-01

    Full Text Available Abstract Background Muscle fascicle pennation angle (PA is an important parameter related to musculoskeletal functions, and ultrasound imaging has been widely used for measuring PA, but manually and frame by frame in most cases. We have earlier reported an automatic method to estimate aponeurosis orientation based on Gabor transform and Revoting Hough Transform (RVHT. Methods In this paper, we proposed a method to estimate the overall orientation of muscle fascicles in a region of interest, in order to complete computing the orientation of the other side of the pennation angle, but the side found by RVHT. The measurements for orientations of both fascicles and aponeurosis were conducted in each frame of ultrasound images, and then the dynamic change of pennation angle during muscle contraction was obtained automatically. The method for fascicle orientation estimation was evaluated using synthetic images with different noise levels and later on 500 ultrasound images of human gastrocnemius muscles during isometric plantarflexion. Results The muscle fascicle orientations were also estimated manually by two operators. From the results it’s found that the proposed automatic method demonstrated a comparable performance to the manual method. Conclusions With the proposed methods, ultrasound measurement for muscle pennation angles can be more widely used for functional assessment of muscles.

  9. The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article.

    Science.gov (United States)

    Shi, Wen; Tian, Dan; Liu, Da; Yin, Jing; Huang, Ying

    2017-08-01

    Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints.This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed.The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P  .05).Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration.

  10. A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound Phantoms.

    Science.gov (United States)

    Scorza, A; Conforto, S; D'Anna, C; Sciuto, S A

    2015-01-01

    To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. In the present study variations on some features of the B-mode image were measured when the ultrasound probe is handled by the technician in a routine image quality test: ultrasound phantom images from two array transducers are processed to evaluate measurement dispersion in distance accuracy, high contrast spatial resolution and penetration depth when probe is handled by the operator. All measurements are done by means of an in-house image analysis software that minimizes errors due to operator's visual acuity and subjective judgment while influences of ultrasound transducer position on quality assurance test results are estimated as expanded uncertainties on parameters above (measurement reproducibility at 95 percent confidence level): depending on the probe model, they ranged from ±0.1 to ±1.9 mm in high contrast spatial resolution, from ±0.1 to ±5.5 percent in distance measurements error and from ±1 to ±10 mm in maximum depth of signal visualization. Although numerical results are limited to the two examined probes, they confirm some predictions based on general working principles of diagnostic ultrasound systems: (a) measurements strongly depend on settings as well on phantoms features, probes and parameters investigated; (b) relative uncertainty due to probe manipulation on spatial resolution can be very high, i.e. from 10 to more than 30 percent; (c) Field of View settings must be taken into account for measurement reproducibility as well as Dynamic Range compression and phantom attenuation.

  11. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  12. Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound

    DEFF Research Database (Denmark)

    Olesen, Jacob Bjerring; Traberg, Marie Sand; Pihl, Michael Johannes

    2013-01-01

    This paper demonstrates how pressure gradients in a pulsatile flow environment can be measured non-invasively using ultrasound. The proposed method relies on vector velocity fields acquired from ultrasound data. 2-D flow data are acquired at 18-23 frames/sec using the Transverse Oscillation...... approach. Pressure gradients are calculated from the measured velocity fields using the Navier-Stokes equation. Velocity fields are measured during constant and pulsating flow on a carotid bifurcation phantom and on a common carotid artery in-vivo. Scanning is performed with a 5 MHz BK8670 linear...... transducer using a BK Medical 2202 UltraView Pro Focus scanner. The calculated pressure gradients are validated through a finite element simulation of the constant flow model. The geometry of the flow simulation model is reproduced using MRI data, thereby providing identical flow domains in measurement...

  13. Measurements of heel pad thickness in normal Koreans by ultrasound and conventional X-ray

    International Nuclear Information System (INIS)

    Chung, Bong Lin; Kim, Yang Su; Kim, Kun Sang

    1987-01-01

    The measurement of heel pad thickness (HPT) has never been done by ultrasound in healthy Korean. To establish normal standard value of HPT in Koreans, 87 healthy volunteers were examined using 10MHZ high resolution ultrasound. As a control, measurement of HPT were done in 46 healthy volunteers on conventional X-ray. The results are as follows; 1. In ultrasonic measurement cases, the mean value of right HPT is 15.8 ± 1.9 mm and the mean value of left HPT is 15.4 ± 2.0mm. In X-ray measurement cases, the mean value of right HPT is 19.9 ± 2.17mm and the mean value of left HPT is 19.8 ± 2.28mm. 2. Maximum value of HPT is 20.8mm in ultrasonic measurement cases, 23mm in X-ray measurement cases. 3. The value of HPT is well correlated with weight, height both in ultrasound and in X-ray measurement (ρ < 0.05). Correlation between the value of HPT and age is not evident (correlation coefficients = -0.18, -0.15). There is no significant difference between left and right foot (ρ < 0.05), and male and female (ρ < 0.05). 4. The results can be considered that there is no significant difference in normal standard value of HPT between Koreans and white, and that upper limit of normal in Koreans is 23mm by conventional X-ray

  14. Agreement between anatomic and ultrasound measurements of femoral trochlear depth

    DEFF Research Database (Denmark)

    Miles, James Edward; Westrup, Ulrik; Eriksen, Thomas

    and ultrasonographic measurements of trochlear depth using the red fox hind limb as a canine surrogate, dividing the trochlea into five regions from the origin of the caudal cruciate ligament to the proximal aspect of the trochlea. We found reasonable agreement between anatomic and ultrasonographic measurements...

  15. The effects of serial intravascular transfusions in ascitic/hydropic RhD-alloimmunized fetuses.

    Science.gov (United States)

    Craparo, F J; Bonati, F; Gementi, P; Nicolini, U

    2005-02-01

    To evaluate the effects of serial intravascular transfusions on RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion by measuring multiple hematological/biochemical blood variables. Thirty-one singleton pregnancies were referred for management of RhD alloimmunization. Seven fetuses had hydrops on presentation and were transfused immediately. The remainder underwent weekly ultrasound examinations, and fetal blood sampling and transfusion were performed on development of ascites. In the 104 samples collected overall from the 31 fetuses, glucose, uric acid, urea, creatinine, total protein, total and direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase, alkaline phosphatase, lactic dehydrogenase, amylase, pseudocholinesterase (PCHE), creatine kinase, triglycerides and cholesterol were measured and compared with a reference range for non-anemic fetuses. The median gestational age at first transfusion was 26 (range, 18-34) weeks. There were three fetal losses after the first transfusion, two of which were due to procedure-related complications; one further loss occurred. At the first transfusion fetal hematocrit, pO2, total protein, PCHE, creatinine and urea concentrations were significantly decreased compared to reference data, while total and direct bilirubin, AST, ALT, amylase, triglyceride and uric acid concentrations were increased. In all surviving fetuses ascites/hydrops had disappeared by the second transfusion. Fetal pO2, total protein, AST, ALT and PCHE concentrations had normalized by the third transfusion. Correction of fetal anemia did not affect the other variables. RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion had a survival rate of 87%. Alterations of several biochemical fetal blood indices are present at the first sampling/transfusion, but most variables normalize with intravascular transfusions. Copyright 2005 ISUOG.

  16. Accuracy of ultrasound-measured bladder wall thickness for the ...

    African Journals Online (AJOL)

    M.M. Ali

    measured urinary bladder wall thickness. (BWT) in the diagnosis of detrusor overactivity (DO). Subjects and methods: Patients who had undergone urodynamic testing due to irritative lower urinary tract symptoms (LUTS) were evaluated for ...

  17. Interleaved quantitative BOLD: Combining extravascular R2' - and intravascular R2-measurements for estimation of deoxygenated blood volume and hemoglobin oxygen saturation.

    Science.gov (United States)

    Lee, Hyunyeol; Englund, Erin K; Wehrli, Felix W

    2018-03-23

    Quantitative BOLD (qBOLD), a non-invasive MRI method for assessment of hemodynamic and metabolic properties of the brain in the baseline state, provides spatial maps of deoxygenated blood volume fraction (DBV) and hemoglobin oxygen saturation (HbO 2 ) by means of an analytical model for the temporal evolution of free-induction-decay signals in the extravascular compartment. However, mutual coupling between DBV and HbO 2 in the signal model results in considerable estimation uncertainty precluding achievement of a unique set of solutions. To address this problem, we developed an interleaved qBOLD method (iqBOLD) that combines extravascular R 2 ' and intravascular R 2 mapping techniques so as to obtain prior knowledge for the two unknown parameters. To achieve these goals, asymmetric spin echo and velocity-selective spin-labeling (VSSL) modules were interleaved in a single pulse sequence. Prior to VSSL, arterial blood and CSF signals were suppressed to produce reliable estimates for cerebral venous blood volume fraction (CBV v ) as well as venous blood R 2 (to yield HbO 2 ). Parameter maps derived from the VSSL module were employed to initialize DBV and HbO 2 in the qBOLD processing. Numerical simulations and in vivo experiments at 3 T were performed to evaluate the performance of iqBOLD in comparison to the parent qBOLD method. Data obtained in eight healthy subjects yielded plausible values averaging 60.1 ± 3.3% for HbO 2 and 3.1 ± 0.5 and 2.0 ± 0.4% for DBV in gray and white matter, respectively. Furthermore, the results show that prior estimates of CBV v and HbO 2 from the VSSL component enhance the solution stability in the qBOLD processing, and thus suggest the feasibility of iqBOLD as a promising alternative to the conventional technique for quantifying neurometabolic parameters. Copyright © 2018. Published by Elsevier Inc.

  18. Third trimester ultrasound soft-tissue measurements accurately predicts macrosomia.

    Science.gov (United States)

    Maruotti, Giuseppe Maria; Saccone, Gabriele; Martinelli, Pasquale

    2017-04-01

    To evaluate the accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia. Electronic databases were searched from their inception until September 2015 with no limit for language. We included only studies assessing the accuracy of sonographic measurements of fetal soft tissue in the abdomen or thigh in the prediction of macrosomia  ≥34 weeks of gestation. The primary outcome was the accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia. We generated the forest plot for the pooled sensitivity and specificity with 95% confidence interval (CI). Additionally, summary receiver-operating characteristics (ROC) curves were plotted and the area under the curve (AUC) was also computed to evaluate the overall performance of the diagnostic test accuracy. Three studies, including 287 singleton gestations, were analyzed. The pooled sensitivity of sonographic measurements of abdominal or thigh fetal soft tissue in the prediction of macrosomia was 80% (95% CI: 66-89%) and the pooled specificity was 95% (95% CI: 91-97%). The AUC for diagnostic accuracy of sonographic measurements of fetal soft tissue in the prediction of macrosomia was 0.92 and suggested high diagnostic accuracy. Third-trimester sonographic measurements of fetal soft tissue after 34 weeks may help to detect macrosomia with a high degree of accuracy. The pooled detection rate was 80%. A standardization of measurements criteria, reproducibility, building reference charts of fetal subcutaneous tissue and large studies to assess the optimal cutoff of fetal adipose thickness are necessary before the introduction of fetal soft-tissue markers in the clinical practice.

  19. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  20. AMH MEASUREMENT VERSUS OVARIAN ULTRASOUND IN THE DIAGNOSIS OF POLYCYSTIC OVARY SYNDROME IN DIFFERENT PHENOTYPES.

    Science.gov (United States)

    Carmina, Enrico; Campagna, Anna M; Fruzzetti, Franca; Lobo, Rogerio A

    2016-03-01

    This study was designed to assess the value of serum anti-Müllerian hormone (AMH) in the diagnosis of polycystic ovary syndrome (PCOS) in various phenotypes and to assess ovarian ultrasound parameters. We performed a retrospective matched controlled study of 113 females with various PCOS phenotypes and 47 matched controls. The diagnostic utility of AMH measurement and ovarian ultrasound were compared. Using receiver operating characteristic (ROC) curve analyses, the threshold for AMH (>4.7 ng/mL) and ultrasound parameters (follicle number per ovary [FNPO] >22 and ovarian volume [OV] >8 cc) were established. In the entire cohort, AMH had a low sensitivity of 79%; while FNPO and OV were 93% and 68%, respectively. Specificities ranged from 85 to 96%. In classic anovulatory PCOS, AMH exhibited a sensitivity of 91%, and for FNPO and OV the corresponding sensitivities were 92% and 72%. In the ovulatory phenotype, AMH sensitivity was only 50%, while FNPO and OV were 95% and 50%, respectively. In the nonhyperandrogenic phenotype, the sensitivity of AMH was 53% while those for FNPO and OV were 93% and 67%. AMH does not appear to be helpful for all subjects with PCOS but may be of some value in those who are anovulatory. However, FNPO was highly sensitive in all phenotypes, and was the single best criterion assessed for all subjects, suggesting the important role of ultrasound.

  1. Comparison between body fat measurements obtained by portable ultrasound and caliper in young adults.

    Science.gov (United States)

    Ulbricht, L; Neves, E B; Ripka, W L; Romaneli, E F R

    2012-01-01

    The objective of this study was to compare and correlate the Portable Ultra Sound (US) measuring technique to the skinfold measuring technique (SF) to estimate body fat percentage (%F) in young adults. Sixty military were evaluated, all males, divided in two groups: Group 1 (normal) composed by 30 military with Body Mass Index (BMI) until 24.99 kg/m(2) and Group 2 (overweight) composed by 30 military with BMI > 25 kg/m(2). Weight, height, skinfolds and ultrasound were measured in 9 points (triceps, subscapular, biceps, chest, medium axillary, abdominal, suprailiac, thigh and calf). Body fat average values obtained by skinfold thickness and ultrasound measurements were 13.25 ± 6.32 % and 12.73 ± 5.95 % respectively. Despite significant differences in measurements of each anatomical site, it was possible to verify that the total final body fat percentage calculated by both techniques did not present significant differences and that overweight group presented greater similarity between the values obtained using caliper and ultrasound equipment.

  2. Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.

    Science.gov (United States)

    Kalashyan, Hayrapet; Shuaib, Ashfaq; Gibson, Patrick H; Romanchuk, Helen; Saqqur, Maher; Khan, Khurshid; Osborne, Jonathon; Becher, Harald

    2014-02-01

    There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing clinically indicated carotid ultrasound. Consecutive patients with a history of stroke or transient ischemic attack (TIA) and having a plaque in the internal carotid artery (ICA) were recruited for this study. Imaging was performed using a Philips iU 22 ultrasound system equipped with the single sweep volumetric transducer vL 13-5. Analysis was performed offline with software provided by the manufacturer. Two independent observers performed all measurements. Of 137 arteries studied (from 79 patients), plaque and artery volumes could be measured in 106 (77%). Reproducibility of plaque volume measurements was assessed in 82 arteries. Bland-Altman analysis demonstrated good inter-observer reproducibility with limits of agreement -0.06 to +0.07 ml. The mean percentage difference between two observers was 5.6% ± 6.0%. Reproducibility of artery volume measurement was assessed in 31 cases. Bland-Altman analysis demonstrated limits of agreement from -0.15 to +0.15 ml. The mean percentage difference was 6.4 ± 5.9%. The new automated single sweep 3D ultrasound is feasible in the majority of patients. Good reproducibility in plaque and artery volume measurements makes this technique suitable for serial assessment of carotid plaques. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  3. Ultrasound power measurements of HITU transducer with a more stable radiation force balance

    International Nuclear Information System (INIS)

    Karaboece, B; Sadiko'lu, E; Bilgic, E

    2011-01-01

    A new radiation force balance (RFB) system was established at Turkish National Metrology Institute (UME) Ultrasonics Laboratory for High intensity therapeutic ultrasound (HITU) power measurements. The new system is highly stable at high power levels up to 500 Watts. The measurement system consists of a Plexiglas cylindrical balance arm, target mounting scale disks, conical reflecting and absorbing targets, adjustment nuts, and a hanging wire. Both of the two sides of balance were mounted similar size and weight targets. The equilibrium of the balance arm can be adjusted with nuts on screws located at both sides of the balance arm. Transducer was mounted to bottom of water tank. Absorbers in the bottom and the near walls of the tank were used for reflecting target case. Ultrasound power was applied to one scale of the balance where the reflecting/absorbing target was mounted and corresponding force was measured on the other scale of balance where was connected to a balance with a thin wire while the thin rest standing on a support. Ultrasound power of two HITU transducers at frequencies 0.93 MHz, 1.1 MHz and 3.3 MHz were measured with conventional and new system, the values were compared and uncertainty components were assessed in this paper.

  4. Ultrasound power measurements of HITU transducer with a more stable radiation force balance

    Energy Technology Data Exchange (ETDEWEB)

    Karaboece, B; Sadiko' lu, E; Bilgic, E, E-mail: baki.karaboce@ume.tubitak.gov.t [Tuebitak Ulusal Metroloji Enstituesue (UME), P.K. 54 41470 Gebze-Kocaeli (Turkey)

    2011-02-01

    A new radiation force balance (RFB) system was established at Turkish National Metrology Institute (UME) Ultrasonics Laboratory for High intensity therapeutic ultrasound (HITU) power measurements. The new system is highly stable at high power levels up to 500 Watts. The measurement system consists of a Plexiglas cylindrical balance arm, target mounting scale disks, conical reflecting and absorbing targets, adjustment nuts, and a hanging wire. Both of the two sides of balance were mounted similar size and weight targets. The equilibrium of the balance arm can be adjusted with nuts on screws located at both sides of the balance arm. Transducer was mounted to bottom of water tank. Absorbers in the bottom and the near walls of the tank were used for reflecting target case. Ultrasound power was applied to one scale of the balance where the reflecting/absorbing target was mounted and corresponding force was measured on the other scale of balance where was connected to a balance with a thin wire while the thin rest standing on a support. Ultrasound power of two HITU transducers at frequencies 0.93 MHz, 1.1 MHz and 3.3 MHz were measured with conventional and new system, the values were compared and uncertainty components were assessed in this paper.

  5. Accurate acoustic power measurement for low-intensity focused ultrasound using focal axial vibration velocity

    Science.gov (United States)

    Tao, Chenyang; Guo, Gepu; Ma, Qingyu; Tu, Juan; Zhang, Dong; Hu, Jimin

    2017-07-01

    Low-intensity focused ultrasound is a form of therapy that can have reversible acoustothermal effects on biological tissue, depending on the exposure parameters. The acoustic power (AP) should be chosen with caution for the sake of safety. To recover the energy of counteracted radial vibrations at the focal point, an accurate AP measurement method using the focal axial vibration velocity (FAVV) is proposed in explicit formulae and is demonstrated experimentally using a laser vibrometer. The experimental APs for two transducers agree well with theoretical calculations and numerical simulations, showing that AP is proportional to the square of the FAVV, with a fixed power gain determined by the physical parameters of the transducers. The favorable results suggest that the FAVV can be used as a valuable parameter for non-contact AP measurement, providing a new strategy for accurate power control for low-intensity focused ultrasound in biomedical engineering.

  6. Central Corneal Thickness Measurement by Ultrasound versus Orbscan II

    Directory of Open Access Journals (Sweden)

    Amir Faramarzi

    2008-12-01

    Full Text Available

    PURPOSE: To compare Orbscan II and ultrasonic pachymetry for measurement of central corneal thickness (CCT in eyes scheduled for keratorefractive surgery. METHODS: CCT was measured using Orbscan II (Bausch & Lomb, USA and then by ultrasonic pachymetry (Tomey SP-3000, Tomey Ltd, Japan in 100 eyes of 100 patients with no history of ocular surgery scheduled for excimer laser refractive surgery. RESULTS: Mean CCT was 544.7±35.5 (range 453-637 µm by ultrasonic pachymetry versus 546.9±41.6 (range 435-648 µm measured by Orbscan II applying an acoustic factor of 0.92 (P=0.14. The standard deviation of measurements was greater with Orbscan pachymetry but the difference was not statistically significant. CONCLUSION: CCT measurements by Orbscan II (applying an acoustic factor and by ultrasonic pachymetry are not significantly different; however, when CCT readings by Orbscan II are in the lower range, it is advisable to recheck the measurements using ultrasonic pachymetry.

  1. Comparative ultrasound measurement of normal thyroid gland dimensions in school aged children in our local environment.

    Science.gov (United States)

    Marchie, T T; Oyobere, O; Eze, K C

    2012-01-01

    The objective of this study was to determine the measurement of normal range of ultrasound (US) thyroid gland dimensions in school-aged children (6-16 years) in our environment and compared with what is obtained elsewhere. A prospective ultrasound measurement study done in University of Benin Teaching Hospital Benin, Nigeria. A prospective ultrasound (US) study of thyroid dimensions of 500 school-aged children in our environment consisting of 227 boys and 273 girls was done from 1 December 2006 to July 2007. The subjects were examined by the authors and subjects with palpable abnormal thyroid gland were excluded from the study. The thyroid dimensions (length, height, and diameter) were taken for each lobe by means of ultrasound (US). In addition volume of each thyroid lobe was calculated and the summation of volume of the lobes was taken as thyroid gland volume of each subject. Also height and weight of patients were documented from which the subject's body surface was calculated. Incidental thyroid gland lesion in US was excluded from the study. Using the Statistical program of social science (SPSS) and INSTAT (Graph Pad Inc. USA) the data were analyzed. Informed consent was obtained from all the subjects and the study was done in line with the ethical guidelines of the centers. The US thyroid gland volume in school-aged children in Benin City from this study ranges between 1.17 cm 3 and 7.19 cm 3 , mean volume range of 1.76-4.95 cm 3 , median volume range of 1.73-4.73 cm 3 , and range of standard deviation from 0.39 cm 3 to 1.49 cm 3 . The average mean thyroid volume is 2.32 cm 3 with the following average dimensions; anteroposterior right lobe =1.06 cm, mediolateral right lobe = 1.01 cm and craniocaudal right lobe = 2.34 cm, and anteroposterior left lobe = 1.01 cm, mediolateral left lobe = 1.04 cm and craniocaudal left lobe = 2.41 cm for both boys and girls respectively. These data are significantly lower than data obtained by European based World Health

  2. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  3. A noninvasive ultrasound elastography technique for measuring surface waves on the lung.

    Science.gov (United States)

    Zhang, Xiaoming; Osborn, Thomas; Kalra, Sanjay

    2016-09-01

    The purpose of this work was to demonstrate an ultrasound based surface wave elastography (SWE) technique for generating and detecting surface waves on the lung. The motivation was to develop a noninvasive technique for assessing superficial lung tissue disease including interstitial lung disease (ILD). ILD comprises a number of lung disorders in which the lung tissue is stiffened and damaged due to fibrosis of the lung tissue. Currently, chest radiographs and computed tomography (CT) are the most common clinical methods for evaluating lung disease, but they are associated with radiation and cannot measure lung mechanical properties. The novelty of SWE is to develop a noninvasive and nonionizing technique to measure the elastic properties of superficial lung tissue. We propose to generate waves on the lung surface through wave propagation from a local harmonic vibration excitation on the chest through an intercostal space. The resulting surface wave propagation on the lung is detected using an ultrasound probe through the intercostal space. To demonstrate that surface waves can be generated on the lung, an ex vivo muscle-lung model was developed to evaluate lung surface wave generation and detection. In this model, swine muscle was laid atop a swine lung. A vibration excitation of 0.1s 100Hz wave was generated on the muscle surface and the surface waves on the lung were detected using a linear array ultrasound probe at 5MHz. To test its feasibility for patient use, SWE was used to measure both lungs of an ILD patient through eight intercostal spaces. The mean wave speed was 1.71±0.20m/s (±SD) at the functional residual capacity, while the mean wave speed was 2.36±0.33m/s at the total lung capacity. These studies support the feasibility of SWE for noninvasive measurement of elastic properties of lung and demonstrate potential for assessment of ILD. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Dosimetric calculus in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho; Stabin, Michael Gregory [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear

    2000-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Two stent sources employing {sup 32}P are also simulated. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  5. Attenuation Measuring Ultrasound Shearwave Elastography and in vivo application in post-transplant liver patients

    Science.gov (United States)

    Nenadic, Ivan Z.; Qiang, Bo; Urban, Matthew W.; Zhao, Heng; Sanchez, William; Greenleaf, James F.; Chen, Shigao

    2017-01-01

    Ultrasound and magnetic resonance elastography techniques are used to assess mechanical properties of soft tissues. Tissue stiffness is related to various pathologies such as fibrosis, loss of compliance, and cancer. One way to perform elastography is measuring shear wave velocity of propagating waves in tissue induced by intrinsic motion or an external source of vibration, and relating the shear wave velocity to tissue elasticity. All tissues are inherently viscoelastic and ignoring viscosity biases the velocity-based estimates of elasticity and ignores a potentially important parameter of tissue health. We present Attenuation Measuring Ultrasound Shearwave Elastography (AMUSE), a technique that independently measures both shear wave velocity and attenuation in tissue and therefore allows characterization of viscoelasticity without using a rheological model. The theoretical basis for AMUSE is first derived and validated in finite element simulations. AMUSE is validated against the traditional methods for assessing shear wave velocity (phase gradient) and attenuation (amplitude decay) in tissue mimicking phantoms and excised tissue. The results agreed within one standard deviation. AMUSE was used to measure shear wave velocity and attenuation in 15 transplanted livers in patients with potential acute rejection, and the results were compared with the biopsy findings in a preliminary study. The comparison showed excellent agreement and suggests that AMUSE can be used to separate transplanted livers with acute rejection from livers with no rejection. PMID:28000623

  6. Reproducibility of rehabilitative ultrasound imaging for the measurement of abdominal muscle activity: a systematic review.

    Science.gov (United States)

    Costa, Leonardo Oliveira Pena; Maher, Chris G; Latimer, Jane; Smeets, Rob J E M

    2009-08-01

    Rehabilitative ultrasound imaging (RUSI) measures of abdominal wall muscles are used to indirectly measure muscle activity. These measures are used to identify suitable patients and to monitor progress of motor control exercise treatment of people with low back pain. The purpose of this study was to systematically review reproducibility studies of RUSI for measuring thickness of abdominal wall muscles. Eligible studies were identified via searches of MEDLINE, EMBASE, and CINAHL. The authors also searched personal files and tracked references of the retrieved studies via the Web of Science Index. Studies involving any type of reliability and or agreement of any type of ultrasound measurements (B or M mode) for any of the abdominal wall muscles were selected. Two independent reviewers extracted data and assessed methodological quality. Due to heterogeneity of the studies' designs, pooling the data for a meta-analysis was not possible. Twenty-one studies were included, and these studies were typically of low quality and studied subjects who were healthy rather than people seeking care for low back pain. The studies reported good to excellent reliability for single measures of thickness and poor to good reliability for measures of thickness change (reflecting the muscle activity). Interestingly, no studies checked reliability of measures of the difference in thickness changes over time (representing improvement or deterioration in muscle activity). The current evidence of the reproducibility of RUSI for measuring abdominal muscle activity is based mainly on studies with suboptimal designs and the study of people who were healthy. The critical question of whether RUSI provides reliable measures of improvement in abdominal muscle activity remains to be evaluated.

  7. Ultrasound imaging measurement of submerged topography in the muddy water physical model

    International Nuclear Information System (INIS)

    Xiao, Xiongwu; Guo, Bingxuan; Li, Deren; Zhang, Peng; Zang, Yu-fu; Zou, Xianjian; Liu, Jian-chen

    2015-01-01

    The real-time, accurate measurement of submerged topography is vital for the analysis of riverbed erosion and deposition. This paper describes a novel method of measuring submerged topography in the B-scan image obtained using an ultrasound imaging device. Results show the distribution of gray values in the image has a process of mutation. This mutation process can be used to adaptively track the topographic lines between riverbed and water, based on the continuity of topography in the horizontal direction. The extracted topographic lines, of one pixel width, are processed by a wavelet filtering method. Compared with the actual topography, the measurement accuracy is within 1 mm. It is suitable for the real-time measurement and analysis of all current model topographies with the advantage of good self-adaptation. In particular, it is visible and intuitive for muddy water in the movable-bed model experiment. (paper)

  8. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  9. Disseminated intravascular coagulation and massive obstetric hemorrhage. Management dilemma.

    Science.gov (United States)

    Al-Nuaim, Lulu A; Mustafa, Mohamed S; Abdel Gader, Abdel Galil M

    2002-06-01

    The objective of this retrospective study is to reflect on our experience on an optimal management for major postpartum hemorrhage, which would prevent the occurrence and complications of disseminated intravascular coagulation and minimize maternal mortality and morbidity. Ten cases out of the 30,000 of total deliveries of severe obstetric hemorrhage associated with disseminated intravascular coagulation were studied. This study was carried out over a 7 year period, October 1988 through to September 1995, at the Obstetric Unit, King Khalid University Teaching Hospital, Riyadh, Kingdom of Saudi Arabia. All of the 10 women received packed red blood cells, 8 had fresh frozen plasma, and 6 received platelet transfusion. The 10 cases developed disseminated intravascular coagulation following medical and surgical management, all women needed hysterectomy, 4 subtotal, 6 total, and 5 women had relaparotomy and pelvic packing. Two had bladder injuries. There was no maternal death. An early resort to hysterectomy when conservative measures fail, will minimize maternal morbidity and mortality. In case of continuous bleeding after hysterectomy, pelvic packing proved to be effective.

  10. VALIDATION OF ULTRASOUND AS A NONINVASIVE TOOL TO MEASURE SUBCUTANEOUS FAT DEPTH IN LEATHERBACK SEA TURTLES (DERMOCHELYS CORIACEA).

    Science.gov (United States)

    Harris, Heather S; Benson, Scott R; James, Michael C; Martin, Kelly J; Stacy, Brian A; Daoust, Pierre-Yves; Rist, Paul M; Work, Thierry M; Balazs, George H; Seminoff, Jeffrey A

    2016-03-01

    Leatherback turtles (Dermochelys coriacea) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45-90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- ...

  12. Comparison of sound speed measurements on two different ultrasound tomography devices

    Science.gov (United States)

    Sak, Mark; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Sherman, Mark; Gierach, Gretchen; Malyarenko, Antonina

    2014-03-01

    Ultrasound tomography (UST) employs sound waves to produce three-dimensional images of breast tissue and precisely measures the attenuation of sound speed secondary to breast tissue composition. High breast density is a strong breast cancer risk factor and sound speed is directly proportional to breast density. UST provides a quantitative measure of breast density based on three-dimensional imaging without compression, thereby overcoming the shortcomings of many other imaging modalities. The quantitative nature of the UST breast density measures are tied to an external standard, so sound speed measurement in breast tissue should be independent of specific hardware. The work presented here compares breast sound speed measurement obtained with two different UST devices. The Computerized Ultrasound Risk Evaluation (CURE) system located at the Karmanos Cancer Institute in Detroit, Michigan was recently replaced with the SoftVue ultrasound tomographic device. Ongoing clinical trials have used images generated from both sets of hardware, so maintaining consistency in sound speed measurements is important. During an overlap period when both systems were in the same exam room, a total of 12 patients had one or both of their breasts imaged on both systems on the same day. There were 22 sound speed scans analyzed from each system and the average breast sound speeds were compared. Images were either reconstructed using saved raw data (for both CURE and SoftVue) or were created during the image acquisition (saved in DICOM format for SoftVue scans only). The sound speed measurements from each system were strongly and positively correlated with each other. The average difference in sound speed between the two sets of data was on the order of 1-2 m/s and this result was not statistically significant. The only sets of images that showed a statistical difference were the DICOM images created during the SoftVue scan compared to the SoftVue images reconstructed from the raw data

  13. MR guided focused ultrasound: technical acceptance measures for a clinical system

    Science.gov (United States)

    Gorny, K. R.; Hangiandreou, N. J.; Hesley, G. K.; Gostout, B. S.; McGee, K. P.; Felmlee, J. P.

    2006-06-01

    Magnetic resonance (MR) guided focused ultrasound (MRgFUS) is a hybrid technique which offers efficient and safe focused ultrasound (FUS) treatments of uterine fibroids under MR guidance and monitoring. As a therapy device, MRgFUS requires systematic testing over a wide range of operational parameters prior to use in the clinical environment. We present technical acceptance tests and data for the first clinical MRgFUS system, ExAblate® 2000 (InSightec Inc., Haifa, Israel), that has been FDA approved for treating uterine fibroids. These tests characterize MRgFUS by employing MR temperature measurements in tissue mimicking phantoms. The coronal scan plane is empirically demonstrated to be most reliable for measuring temperature elevations resulting from high intensity ultrasound (US) pulses ('sonications') and shows high sensitivity to changes in sonication parameters. Temperatures measured in the coronal plane were used as a measure of US energy deposited within the focal spot for a range of sonication parameters used in clinical treatments: spot type, spot length, output power, sonication duration, US frequency, and depth of sonication. In addition, MR images acquired during sonications were used to measure effective diameters and lengths of available sonication spot types and lengths. At a constant 60 W output power, the effective spot type diameters were measured to vary between 4.7 ± 0.3 mm and 6.6 ± 0.4 mm; treatment temperatures were found to decrease with increasing spot diameter. Prescribing different spot lengths was found to have no effect on the measured length or on measured temperatures. Tests of MRgFUS positioning accuracy determined errors in the direction parallel to the propagation of the US beam to be significantly greater than those in the perpendicular direction; most sonication spots were erroneously positioned towards the FUS transducer. The tests reported here have been demonstrated to be sufficiently sensitive to detect water leakage

  14. Coagulación intravascular diseminada = Disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Arango Barrientos, Marcos

    2010-12-01

    Full Text Available La coagulación intravascular diseminada (CID es una entidad clínica frecuente que se presenta como fenómeno secundario a diversas enfermedades entre las cuales se destacan las infecciones graves, las neoplasias y las catástrofes obstétricas. Se caracteriza por una activación difusa y simultánea de los sistemas endógenos de la coagulación y la fibrinólisis. El depósito de pequeños trombos en la circulación conduce finalmente a disfunción orgánica múltiple y en algunos casos a la muerte. Las manifestaciones clínicas pueden incluir fenómenos trombóticos y hemorrágicos. Se ha propuesto un puntaje de fácil aplicación para simplificar el diagnóstico de la entidad. El tratamiento incluye el control específico de la causa subyacente que favorece la aparición de la CID, el soporte con hemoderivados en pacientes con manifestaciones de sangrado y la anticoagulación terapéutica en pacientes con trombosis mayores. El desarrollo de CID es un factor pronóstico adverso que aumenta significativamente la tasa de mortalidad. En este artículo de revisión se incluyen los siguientes aspectos de la CID: historia, epidemiología, clasificación, entidades asociadas, fisiopatología, clínica, diagnóstico, tratamiento y pronóstico.

  15. Dosimetry in intravascular brachytherapy; Calculos dosimetricos em braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing {sup 32} P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  18. [Measurement on printed paper strips or on the ultrasound device with computer assistance - which technique is more accurate in paediatric hip ultrasound?].

    Science.gov (United States)

    Peterlein, C-D; Schüttler, K-F; Timmesfeld, N; Lakemeier, S; Görg, C; Fuchs-Winkelmann, S; Schofer, M

    2012-04-01

    Two different measurement techniques of ultrasonograms of the infant hip were evaluated with respect to reproducibility of the Graf classification and variation of α- and β-angles. In a cross-sectional, blinded study, the hips of 207 consecutive newborn babies (101 male; 106 female) were sonographically screened at an average of 2.64 days after birth. Each hip was measured twice by three investigators with different levels of experience - a paediatric orthopaedic surgeon, a senior surgeon and a trained medical student. A mobile ultrasound system (SONOLINE G60S®, Siemens, Erlangen, Germany), equipped with a 7.5 MHz linear transducer, was used. Both hip joints were measured twice by all three investigators. The measurement was performed 6-8 weeks later in a blinded manner. The sonograms were initially printed out on high-quality paper strips and measured by pencil, ruler and goniometer. Finally, each investigator evaluated the same sonograms computer-assisted, using the trackball and dashboard of the ultrasound system. Concerning intraobserver reliability, we observed a significant reduction of variation both for α- and β-angles in favour of the classic measurement on printed strips (p 0.05). This study demonstrated considerable advantages for the classic measurement of paediatric hip ultrasonograms with pencil and goniometer on printed paper strips compared to computer-aided measurement concerning variation of α- and β-angles. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    limbs) undergoing PTA of the superficial femoral or popliteal artery. The degree of stenosis, the diameter and area of the lumen and the morphological changes in the plaque were related to the short-term patency of the intervention, as evaluated by duplex scan and ankle branchial index. RESULTS: Fifteen...... arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  20. Intravascular ultrasound for iliac artery imaging. Clinical review

    DEFF Research Database (Denmark)

    Vogt, K G; Schroeder, T V

    2001-01-01

    IVUS is able to produce trans-sectional images of the iliac arteries at a high resolution. The three layered appearance of the arterial wall can be visualized. In the atherosclerotic diseased artery calcified plaques can be discerned from non-calcified plaques, and the distribution of the plaque......-eccentric or concentric-can be determined. IVUS seems to be superior to arteriography in quantifying the degree of stenosis, being able to relate the luminal area to the mediabounded area at the same site of the artery. The discrepancy between IVUS and arteriography is even greater when evaluating residualstenosis after...

  1. Measurement precision and normal range of endometrial thickness in a postmenopausal population by transvaginal ultrasound

    DEFF Research Database (Denmark)

    Warming, L; Ravn, Pernille; Skouby, Sven O.

    2002-01-01

    of the ET. Measurements were performed by transvaginal ultrasound. A subset of the women (n = 178) was examined twice 3 months to 2 years apart to assess the long-term variability. RESULTS: Cross-sectionally, ET varied with length of menopause. During the first 5 years after menopause (YSM) the mean ET...... was 2.3 mm but it decreased by 0.03 mm/year (P changes (P = 0.13). Thereafter there was a minimal increase of 0.01 mm/year (P changes on ET, only women who had...... reached the menopause more than 5 years earlier were entered into the subsequent long-term study. The mean ET was 2.0 mm +/- 1.0 mm with no significant differences within or between the observers' measurements. The precision errors were less than 1 mm. CONCLUSIONS: The normal range of the thickness...

  2. Skin blood flow in humans as a function of environmental temperature measured by ultrasound.

    Science.gov (United States)

    Thoresen, M; Walløe, L

    1980-07-01

    We have measured the blood velocities in arteries supplying the skin in humans both in areas with arteriovenous anastomoses (AVA) and in skin areas without AVA in different temperature situations by means of a pulsed, bidirectional doppler ultrasound instrument. The instrument measures the time average of the instantaneous mean of the blood velocities present in a cross-section of a vessel. So long as the cross-sectional area of the vessel is constant, this average velocity is proportional to volume flow. We observe rapid and large fluctuations in blood velocities in arteries supplying skin areas with AVA in a comfortably warm environment. These fluctuations are substantially larger and more rapid than described by previous authors who have used plethysmograph methods. The blood velocities are more constant both at higher and lower environmental temperatures. There are no similar fluctuations in blood velocity in arteries supplying skin areas without AVA.

  3. Measuring the porosity and compressibility of liquid-suspended porous particles using ultrasound.

    Science.gov (United States)

    Han, Endao; Van Ha, Nigel; Jaeger, Heinrich M

    2017-05-21

    A key parameter describing the behavior of suspensions is the volume fraction ϕ of the solid particles that are dispersed in the liquid. Obtaining accurate values for ϕ becomes difficult for porous particles, because they can absorb some of the liquid. A prime example are the widely used cornstarch suspensions, for which ϕ usually is only estimated from the mass fraction of particles. Here we present a method to measure the effective porosity and compressibility of porous particles with ultrasound. We obtain the speed of sound in dilute cornstarch suspensions at multiple particle concentrations and with different solvent compressibilities. With the measured particle porosity of 0.31 we are able to calculate the volume fraction of the saturated particles reliably.

  4. What is the value of ultrasound soft tissue measurements in the prediction of abnormal fetal growth?

    LENUS (Irish Health Repository)

    Farah, N

    2012-02-01

    Abnormal fetal growth increases the complications of pregnancy not only for the baby but also for the mother. Growth abnormalities also have lifelong consequences. These babies are at increased risk of insulin resistance, diabetes and hypertension later in life. It is important to identify these babies antenatally to optimise their clinical care. Although used extensively antenatally to monitor fetal growth, ultrasound has its limitations. Despite the use of more than 50 different formulae to estimate fetal weight, their performance has been poor at the extremes of fetal weight. Over the past 20 years there has been emerging interest in studying fetal soft tissue measurements to improve detection of growth abnormalities. This review paper outlines the value of soft tissue measurements in identifying fetal growth abnormalities, in estimating fetal weight and in managing diabetes mellitus in pregnancy.

  5. Why Have So Many Intravascular Glucose Monitoring Devices Failed?

    Science.gov (United States)

    Smith, John L; Rice, Mark J

    2015-07-01

    Secondary to the inherent limitations of both point-of-care and central laboratory glucose technologies, continuous glucose measurement has recently enjoyed a high level of investment. Because of the perceived advantages by some of measuring in the intravascular space compared to the subcutaneous tissue, a number of technologies have been developed. In this review, we evaluate nine systems that have shown promise, although only one of these has been cleared for sale in the United States. The detection methodology, regulatory status, technical issues, and company circumstance surrounding each technology are examined. © 2015 Diabetes Technology Society.

  6. Abdominal circumference measurement by ultrasound does not enhance estimating the association of visceral fat with cardiovascular risk.

    Science.gov (United States)

    Seibert, Helena; Pereira, Aline Maria L; Ajzen, Sergio A; Nogueira, Paulo C Koch

    2013-02-01

    To evaluate the association between visceral fat and cardiovascular risk factors and to compare the ultrasonographic measurements of abdominal visceral fat with abdominal circumference (AC). This observational cross-sectional study categorized pubertal and postpubertal adolescents into a control group (n = 49) and an obese group (n = 46). Weight, height, AC, blood pressure, biochemical tests (lipid profile, triacylglycerols, fasting glucose for insulinemia, and serum uric acid), and ultrasound to measure visceral fat were assessed. We found significant differences in the vascular risk variables between the groups, except for total cholesterol and fasting blood glucose level. We also observed that 31 subjects in the control group presented abnormalities in cardiovascular risk factors. The correlations between abdominal visceral fat (measured by ultrasound or the AC) and cardiovascular risk factors were significant. In the entire sample, AC presented better sensitivity and specificity than the ultrasound-measured abdominal visceral fat for identifying the presence of a cluster of at least three cardiovascular risk factors (areas under the receiver operating characteristics curve 0.87 and 0.73, respectively). Ultrasonographic measurements of visceral fat were correlated with cardiovascular risk factors, but this association was also demonstrable with AC measurements. Our results suggest that the measurement of visceral fat by ultrasound is unnecessary for the diagnosis of cardiovascular risk in well-nourished or obese adolescents. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  9. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  10. Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Garcia-Garcia, Hector M

    2015-01-01

    We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the s...

  11. The challenges of measuring in vivo knee collateral ligament strains using ultrasound.

    Science.gov (United States)

    Slane, Laura C; Slane, Josh A; D'hooge, Jan; Scheys, Lennart

    2017-08-16

    Ultrasound-based methods have shown promise in their ability to characterize non-uniform deformations in large energy-storing tendons such as the Achilles and patellar tendons, yet applications to other areas of the body have been largely unexplored. The noninvasive quantification of collateral ligament strain could provide an important clinical metric of knee frontal plane stability, which is relevant in ligament injury and for measuring outcomes following total knee arthroplasty. In this pilot cadaveric experiment, we investigated the possibility of measuring collateral ligament strain with our previously validated speckle-tracking approach, but encountered a number of challenges during both data acquisition and processing. Given the clinical interest in this type of tool, and the fact that this is a developing area of research, the goal of this article is to transparently describe this pilot study, both in terms of methods and results, while also identifying specific challenges to this work and areas for future study. Some challenges faced relate generally to speckle-tracking of soft tissues (e.g. the limitations of using a 2D imaging modality to characterize 3D motion), while others are specific to this application (e.g. the small size and complex anatomy of the collateral ligaments). This work illustrates a clear need for additional studies, particularly relating to the collection of ground-truth data and more thorough validation work. These steps will be critical prior to the translation of ultrasound-based measures of collateral ligament strains into the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Genetic association between body composition measured by ultrasound and visual scores in Brazilian Nelore cattle.

    Science.gov (United States)

    Gordo, D G M; Baldi, F; Lôbo, R B; Koury Filho, W; Sainz, R D; Albuquerque, L G

    2012-12-01

    The objective of this study was to evaluate the genetic variability of body composition traits measured by ultrasound, growth traits, and visual scores as well as their genetic associations in Nelore cattle. A total of 9,765, 13,285, 13,061, 12,811, 3,484, 3,484, 3,483, and 3,303 records of weight at time of ultrasound measure (W550), 12th-13th rib LM area (LMA), backfat thickness (BF), rump fat thickness (RF), visual scores for body structure (BS), finishing precocity (FP), muscling (MS), and sheath and navel characteristics (SN), respectively, were used. The model included contemporary group (defined as year and season of birth, sex, and management group) as a fixed effect and age of dam at calving and age of the animal (linear and quadratic effects) as covariates. The direct additive genetic effect was included as a random effect. The analyses also included 46,157 observations of BW adjusted to 120 d. The (co)variance components were estimated by the restricted maximum likelihood method using a multitrait animal model. Heritability estimates for W550, LMA, BF, RF, BS, FP, MS, and SN were 0.37 ± 0.030, 0.33 ± 0.03, 0.24 ± 0.02, 0.28 ± 0.03, 0.24 ± 0.04, 0.38 ± 0.05, 0.29 ± 0.05, and 0.38 ± 0.06, respectively. The estimated genetic correlations between visual scores and LMA were moderate and positive, ranging from 0.37 to 0.44. Similar results were obtained for the estimated genetic correlations between FP and MS with fat thickness measures (BF and RF). Low genetic correlations were estimated between SN and BS and between SN and the body composition traits, indicating that selection for body composition traits and BS will not affect sheath and navel size. The estimated genetic correlations between weight adjusted to 120 d of age (W120) and W550 and BS were high (0.87 and 0.91) and moderate with LMA (0.49 and 0.55), FP (0.37 and 0.41), and MS (0.47 and 0.55). The visual scores and ultrasound-measured body composition traits have enough genetic variation for

  13. Dynamic contrast enhanced ultrasound assessment of the vascular effects of novel therapeutics in early stage trials.

    Science.gov (United States)

    Leen, Edward; Averkiou, Michalakis; Arditi, Marcel; Burns, Peter; Bokor, Daniela; Gauthier, Thomas; Kono, Yuko; Lucidarme, Olivier

    2012-07-01

    Imaging is key in the accurate monitoring of response to cancer therapies targeting tumour vascularity to inhibit its growth and dissemination. Dynamic contrast enhanced ultrasound (DCE ultrasound) is a quantitative method with the advantage of being non-invasive, widely available, portable, cost effective, highly sensitive and reproducible using agents that are truly intravascular. Under the auspices of the initiative of the Experimental Cancer Medicine Centre Imaging Network, bringing together experts from the UK, Europe and North America for a 2-day workshop in May 2010, this consensus paper aims to provide guidance on the use of DCE ultrasound in the measurement of tumour vascular support in clinical trials. Key Points • DCE ultrasound can quantify and extract specific blood flow parameters, such as flow velocity, relative vascular volume and relative blood flow rate. • DCE ultrasound can be performed repeatedly and is therefore ideally suited for pharmacokinetic and pharmacodynamic studies evaluating vascular-targeted drugs. • DCE ultrasound provides a reproducible method of assessing the vascular effects of therapy in pre-clinical and early clinical trials, which is easily translatable into routine clinical practice.

  14. Characterization of Cavitation Effects in Therapeutic Ultrasound: Sonophoresis Experiments and Quantitative Emission Measurements

    Science.gov (United States)

    Rich, Kyle Thomas

    Fundamental to the use of ultrasound for therapeutic benefit is a comprehensive understanding and identification of the underlying mechanisms. Specifically, consequential bioeffects during therapeutic ultrasound commonly coincide with the onset of microbubble cavitation, especially for drug-delivery applications. Hence, there is a need for monitoring and characterization techniques that provide quantitative metrics for assessing cavitation activity during ultrasound exposure in order to monitor treatment progress, identify interactions of cavitation with tissue, and provide dosimetry metrics for avoiding potentially harmful exposures both for therapeutic and diagnostic purposes. The primary goal of the work presented in this dissertation was to characterize the role of cavitation during sonophoresis using quantitative and system-independent approaches. First, this goal was accomplished using traditional passive cavitation detection techniques to monitor cavitation emissions during in vitro intermediate- (IFS, insonation frequency f 0 = 0.1-1 MHz) and high-frequency sonophoresis (HFS, f0 >1 MHz) treatments of in vitro porcine skin samples in Chapter 2. The relative intensity of subharmonic acoustic emissions from stable cavitation occurring near the skin surface was measured using a single-element PCD and was shown to correspond with reductions in skin resistivity, a surrogate measure of permeability, for all sonophoresis treatments. However, the acoustic emissions measured during sonophoresis provided incommensurable quantities between the different treatment regimes due to unaccounted frequency-dependent variations in the sensitivity of the PCD and diffraction effects in the cavitation-radiated pressure field received by the PCD. Second, methods were developed and employed to characterize the wideband absolute receive sensitivity of single-element focused and unfocused receivers in Chapter 3. By employing these characterization techniques and by accounting for the

  15. Ultrasound-based measurement of liquid-layer thickness: A novel time-domain approach

    Science.gov (United States)

    Praher, Bernhard; Steinbichler, Georg

    2017-01-01

    Measuring the thickness of a thin liquid layer between two solid materials is important when the adequate separation of metallic parts by a lubricant film (e.g., in bearings or mechanical seals) is to be assessed. The challenge in using ultrasound-based systems for such measurements is that the signal from the liquid layer is a superposition of multiple reflections. We have developed an algorithm for reconstructing this superimposed signal in the time domain. By comparing simulated and measured signals, the time-of-flight of the ultrasonic pulse in a layer can be estimated. With the longitudinal sound velocity known, the layer thickness can then be calculated. In laboratory measurements, we validate successfully (maximum relative error 4.9%) our algorithm for layer thicknesses ranging from 30 μm to 200 μm. Furthermore, we tested our method in the high-temperature environment of polymer processing by measuring the clearance between screw and barrel in the plasticisation unit of an injection moulding machine. The results of such measurements can indicate (i) the wear status of the tribo-mechanical screw-barrel system and (ii) unsuitable process conditions.

  16. Ultrasound measures of supraspinatus tendon thickness and acromiohumeral distance in rotator cuff tendinopathy are reliable.

    Science.gov (United States)

    McCreesh, Karen M; Anjum, Shakeel; Crotty, James M; Lewis, Jeremy S

    2016-01-01

    Rotator cuff (RC) tendinopathy has been widely ascribed to impingement of the supraspinatus tendon (SsT) in the subacromial space, measured as the acromiohumeral distance (AHD). Ultrasound (US) is suitable for measuring AHD and SsT thickness, but few reliability studies have been carried out in symptomatic populations, and interrater reliability is unconfirmed. This study aimed to examine the intrarater and interrater reliability of US measurements of AHD and SsT thickness in asymptomatic control subjects and patients with RC tendinopathy. Seventy participants were recruited and grouped as healthy controls (n = 25) and RC tendinopathy (n = 45). Repeated US measurements of AHD and SsT thickness were obtained by one rater in both groups and by two raters in the RC tendinopathy group. Intrarater and interrater reliability coefficients were excellent for both measurements (intraclass correlation > 0.92), but the intrarater reliability was superior. The minimal detectable change values in the symptomatic group were 0.7 mm for AHD and 0.6 mm for SsT thickness for a single experienced examiner; the values rose to 1.2 mm and 1.3 mm, respectively, for the pair of examiners. The results support the reliability of US for the measurement of AHD and SsT thickness in patients with symptomatic RC tendinopathy and provide minimal detectable change values for use in future research studies. © 2015 Wiley Periodicals, Inc.

  17. Development of a method for measuring femoral torsion using real-time ultrasound

    International Nuclear Information System (INIS)

    Hafiz, Eliza; Hiller, Claire E; Nightingale, E Jean; Eisenhuth, John P; Refshauge, Kathryn M; Nicholson, Leslie L; Clarke, Jillian L; Grimaldi, Alison

    2014-01-01

    Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC 2,1  = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting. (paper)

  18. Ultrasound measurement of the corpus callosum and neural development of premature infants

    Science.gov (United States)

    Liu, Fang; Cao, Shikao; Liu, Jiaoran; Du, Zhifang; Guo, Zhimei; Ren, Changjun

    2013-01-01

    Length and thickness of 152 corpus callosa were measured in neonates within 24 hours of birth. Using ultrasonic diagnostic equipment with a neonatal brain-specific probe, corpus callosum length and thickness of the genu, body, and splenium were measured on the standard mid-sagittal plane, and the anteroposterior diameter of the genu was measured in the coronal plane. Results showed that corpus callosum length as well as thickness of the genu and splenium increased with tional age and birth weight, while other measures did not. These three factors on the standard mid-sagittal plane are therefore likely to be suitable for real-time evaluation of corpus callosum velopment in premature infants using cranial ultrasound. Further analysis revealed that thickness of the body and splenium and the anteroposterior diameter of the genu were greater in male infants than in female infants, suggesting that there are sex differences in corpus callosum size during the neonatal period. A second set of measurements were taken from 40 premature infants whose gestational age was 34 weeks or less. Corpus callosum measurements were corrected to a gestational age of 40 weeks, and infants were grouped for analysis depending on the outcome of a neonatal behavioral neurological assessment. Compared with infants with a normal neurological assessment, corpus callosum length and genu and splenium thicknesses were less in those with abnormalities, indicating that corpus callosum growth in premature infants is associated with neurobehavioral development during the early extrauterine stage. PMID:25206553

  19. Reliability and Validity of Ultrasound Cross Sectional Area Measurements for Long-Duration Spaceflight

    Science.gov (United States)

    Scott, Jessica M.; Martin, David S.; Cunningham, David; Matz, Timothy; Caine, Timothy; Hackney, Kyle J.; Arzeno, Natalia; Ploutz-Snyder, Lori

    2010-01-01

    Limb muscle atrophy and the accompanying decline in function can adversely affect the performance of astronauts during mission-related activities and upon re-ambulation in a gravitational environment. Previous characterization of space flight-induced muscle atrophy has been performed using pre and post flight magnetic resonance imaging (MRI). In addition to being costly and time consuming, MRI is an impractical methodology for assessing in-flight changes in muscle size. Given the mobility of ultrasound (US) equipment, it may be more feasible to evaluate changes in muscle size using this technique. PURPOSE: To examine the reliability and validity of using a customized template to acquire panoramic ultrasound (US) images for determining quadriceps and gastrocnemius anatomical cross sectional area (CSA). METHODS: Vastus lateralis (VL), rectus femoris (RF), medial gastrocnemius (MG), and lateral gastrocnemius (LG) CSA were assessed in 10 healthy individuals (36+/-2 yrs) using US and MRI. Panoramic US images were acquired by 2 sonographers using a customized template placed on the thigh and calf and analyzed by the same 2 sonographers (CX50 Philips). MRI images of the leg were acquired while subjects were supine in a 1.5T scanner (Signa Horizon LX, General Electric) and were analyzed by 3 trained investigators. The average of the 2 US and 3 MRI values were used for validity analysis. RESULTS: High inter-experimenter reliability was found for both the US template and MRI analysis as coefficients of variation across muscles ranged from 2.4 to 4.1% and 2.8 to 3.8%, respectively. Significant correlations were found between US and MRI CSA measures (VL, r = 0.85; RF, r = 0.60; MG, r = 0.86; LG, r = 0.73; p reliable measures of leg muscle CSA, and thus could be used to characterize changes in muscle CSA both in flight and on the ground.

  20. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  1. Medical Ultrasound Imaging.

    Science.gov (United States)

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  3. Intravascular leiomyomatosis: an exceptional entity.

    Science.gov (United States)

    Brunel, I; Iacoponi, S; Hernandez, A; Diestro, M D; De Santiago, J; Zapardiel, I

    2016-01-01

    Intravenous leiomyomatosis (IVL) is a rare benign condition characterized by the proliferation of smooth muscle cells originating from either the uterine venous wall or a uterine myoma. This leiomyomatosis extends most frequently to pelvic vessels, but also occasionally into the inferior vena cava and right cardiac chambers. Preoperative diagnosis is difficult and it should be suspected in the presence of cardiac or pelvic masses in women who have undergone hysterectomy or myomectomy previously. The treatment is hysterectomy, normally associated with a bilateral oophorectomy and removing the mass or metastasis if any. The post-surgical follow-up should be performed at long-term and include exploration and imaging, either ultrasound or MRI. The association of antiestrogenic drugs can be useful for disease control, especially in cases where oophorectomy is not performed and the tumor cannot be removed completely.

  4. Neutrophils Cause an Intravascular Traffic Jam.

    Science.gov (United States)

    Minns, Martin S; Pearlman, Eric

    2018-01-10

    Neutrophil swarming is defined by large numbers of cells simultaneously and rapidly migrating to a site of injury or infection. In this issue of Cell Host & Microbe, Lee et al. (2018) demonstrate that intravascular swarming of neutrophils occurs in response to Candida albicans infection and causes vascular occlusion and pathological sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  6. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  7. Disseminated Intravascular Coagulation Following Induction of ...

    African Journals Online (AJOL)

    Background: Disseminated Intravascular coagulopathy (DIC) has been reported following use of Misoprostol which is an old drug with new indications in Obstetrics and. Gynecology. Its effectiveness, low cost, stability in tropical conditions and ease of administration as well as side effects like gastrointestinal effect, uterine ...

  8. Evaluation of the ultrasound reproducibility as a method to measure the subcutaneous tissue of the nasal tip

    Directory of Open Access Journals (Sweden)

    Naves, Marcell de Melo

    2011-07-01

    Full Text Available Introduction: The previous evaluation of the patient's anatomy is crucial to achieve a sharp nasal tip in a rhinoplasty. The thickness of the subcutaneous tissue is indispensable for the esthetical harmony of the area. Techniques to measure such structures on the patient 'in vivo' are not found in literature. Objective: Evaluate the inter-observer inconsistency of the ultrasound method to measure the thickness of the subcutaneous tissue of the nasal tip by way of an ultrasound. Method: 47 volunteers were submitted to a nasal tip ultrasound performed by two radiology specialists, who used the same exam technique with a linear electronic transducer at a frequency between 5 and 9 MHz. The thickness of the subcutaneous tissue was evaluated by measuring the point with the highest protrusion of the largest alar cartilage dome towards skin. Prospective study. Results: The measurement averages of the subcutaneous tissue of the nasal tip achieved by the examiners did not show statistically significant differences (p = 0.5303. When analyzing the reproducibility between examiners, an interclass 'r'correlation coefficient (Pearson 0.9333, i.e., an excellent inter-observer reproducibility was found. Conclusion: The ultrasound proved to be reproducible and examiners satisfactorily agree about evaluating the thickness of the subcutaneous tissue of the skin, thus helping the surgeon perform the pre-surgical analysis and find the best surgical technique for each case.

  9. Review on ultrasound measurement of bladder or detrusor wall thickness in women: techniques, diagnostic utility, and use in clinical trials

    NARCIS (Netherlands)

    Oelke, Matthias; Khullar, Vik; Wijkstra, Hessel

    2013-01-01

    To provide a narrative review of literature evaluating ultrasound techniques for the measurement of bladder wall hypertrophy in women as an alternative to invasive urodynamic assessment for the diagnosis of lower urinary tract symptoms (LUTS). A literature review was performed using PubMed and all

  10. Towards Comparison of Ultrasound Dose Measurements - Current Capabilities and Open Challenges

    Science.gov (United States)

    Durando, G.; Guglielmone, C.; Haller, J.; Georg, O.; Shaw, A.; Martin, E.; Karaböce, B.

    The aim of this work is to evaluate measurement methods for dosimetry and exposimetry quantities that were developed in the EMRP project "Dosimetry for Ultrasound Therapy -DUTy" by comparing the measurement results for three common quantities from three national laboratories. It further aims to investigate the general feasibility of possible future (key) comparisons for dosimetry and exposimetry quantities and to identify possible open challenges towards this goal. The general format is similar to a metrological comparison, with which the National Metrological Institutes, NMIs, are already familiar. The first step involved the agreement of the protocol that was to specify the set of transducers to be circulated and the measurement conditions. Two transducers were circulated and different drive voltage levels and pulsing regimes were defined and tissue mimicking materials (TMMs) characteristics were specified. Each lab was asked to prepare the TMMs for their own measurements with the inclusion of formulations and preparation instructions specified in the protocol. Uncertainties of the input data were to be declared by the participating laboratories.

  11. Rehabilitative ultrasound imaging is a valid measure of trunk muscle size and activation during most isometric sub-maximal contractions: a systematic review.

    Science.gov (United States)

    Koppenhaver, Shane L; Hebert, Jeffrey J; Parent, Eric C; Fritz, Julie M

    2009-01-01

    Is rehabilitative ultrasound imaging a valid measure of trunk muscle size and activation? Are rehabilitative ultrasound imaging measures sensitive to change? Systematic review of studies of criterion-related validity, construct validity, and sensitivity to change. People with low back pain and asymptomatic controls. Trunk muscle size and activation measured by rehabilitative ultrasound imaging, MRI and/or EMG. 37 studies were included. 10 studies investigated criterion-related validity and provided evidence that while ultrasound may be a valid measure of trunk muscle size, the validity of ultrasound to quantify muscle activation is context-dependent, depending on the muscle involved, the contraction strategy utilised, and the intensity of muscle contraction. 23 studies provided evidence of construct validity by demonstrating the ability of ultrasound measurement to differentiate individuals in terms of back pain, anthropometry, and postures. Six studies contained a limited amount of information about sensitivity to change. CONCLUSIONS. It is valid to use rehabilitative ultrasound imaging to measure trunk muscle size and activation during most isometric sub-maximal contractions. Ultrasound measures appear sensitive to both positive and negative change.

  12. Common fetal measurements: A comparison between ultrasound and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Parkar, Anagha P. (Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway)); Olsen, Oeystein E.; Rosendahl, Karen (Diagnostic Radiology, Great Ormond Street Hospital for Children, London (United Kingdom)), e-mail: rosenk@gosh.nhs.uk; Gjelland, Knut; Kiserud, Torvid (Fetal Medicine Unit, Dept. of Obstetrics and Gynecology, Haukeland Univ. Hospital, Bergen (Norway))

    2010-01-15

    Background: Ultrasound has been the method of choice for antenatal fetal assessment for the past three decades; however, problems may arise in cases of oligohydramnion, unfavorable position of the fetus, and maternal obesity. Purpose: To compare ultrasound (US) and magnetic resonance imaging (MRI) for common fetal measurements at 19-30 weeks' gestation, and to assess the effect of high maternal body-mass index (BMI). Material and Methods: 59 low-risk singleton pregnancies were enrolled in a prospective blinded cross-sectional study. In a first session, an experienced obstetrician used a high-resolution US technique and in a second session on the same day MRI was used to measure biparietal diameter (BPD), head circumference (HC), mean abdominal diameter (MAD), abdominal circumference (AC), and femur length (FL). Inter- and intraobserver and intermodality variability was determined using Bland-Altman plots. The effect of maternal BMI was assessed using Spearman's statistics. Results: A total of 45 women aged 19-43 years (median 29 years) attended both US and MRI at median 22 weeks' gestation. The mean differences between US and MRI were 1.6 mm for HC (95% confidence interval [CI] -1.0, 4.3 mm), 1 mm for AC (95% CI -0.2, 4.0 mm), 0.2 mm for MAD (95% CI -0.7, 1.2 mm), 2.2 mm for BPD (95% CI 1.7, 2.7 mm), and 4.6 mm for FL (95% CI 2.9, 6.4 mm). Maternal BMI did not affect the results (Spearman' rho 0.054-0.277; P=NS). The intraobserver agreement for all MRI measurements was acceptable, except for FL, while the interobserver agreement was poor. Conclusion: There was good agreement between US and MRI for common fetal measurements, but not for all (i.e., BPD and particularly FL). MRI had a poor interobserver agreement, underscoring the need for technical refinement and reference ranges specifically established for MRI

  13. Body composition in sport: a comparison of a novel ultrasound imaging technique to measure subcutaneous fat tissue compared with skinfold measurement.

    Science.gov (United States)

    Müller, Wolfram; Horn, Martin; Fürhapter-Rieger, Alfred; Kainz, Philipp; Kröpfl, Julia M; Maughan, Ronald J; Ahammer, Helmut

    2013-11-01

    Extremely low weight and rapid changes in weight and body composition have become major concerns in many sports, but sufficiently accurate field methods for body composition assessment in athletes are missing. This study aimed to explore the use of ultrasound methods for assessment of body fat content in athletes. 19 female athletes (stature: 1.67(± 0.06) m, weight: 59.6(± 7.6) kg; age: 19.5(± 3.3) years) were investigated by three observers using a novel ultrasound method for thickness measurement of uncompressed subcutaneous adipose tissue and of embedded structures. Two observers also measured skinfold thickness at eight International Society for the Advancement of Kinanthrometry (ISAK) sites; mean skinfold values were compared to mean subcutaneous adipose tissue thicknesses measured by ultrasound. Interobserver reliability of imaging and evaluation obtained by this ultrasound technique: intraclass correlation coefficient ICC=0.968 (95% CI 0.957 to 0.977); evaluation of given images: ICC=0.997 (0.993 to 0.999). Skinfold compared to ultrasound thickness showed that compressibility of subcutaneous adipose tissue depends largely on the site and the person: regression slopes ranged from 0.61 (biceps) to 1.59 (thigh) and CIs were large. Limits of agreement ranged from 2.6 to 8.6 mm. Regression lines did not intercept the skinfold axis at zero because of the skin thickness being included in the skinfold. The four ISAK trunk sites caused ultrasound imaging problems in 13 of 152 sites (8 ISAK sites, 19 athletes). The ultrasound method allows measurement of uncompressed subcutaneous adipose tissue thickness with an accuracy of 0.1-0.5 mm, depending on the probe frequency. Compressibility of the skinfold depends on the anatomical site, and skin thickness varies by a factor of two. This inevitably limits the skinfold methods for body fat estimation. Ultrasound accuracy for subcutaneous adipose tissue measurement is limited by the plasticity of fat and furrowed tissue

  14. Optimized use of Hough transform in an ultrasound measurement system for human signature analysis

    Science.gov (United States)

    Ricci, R.; Sona, A.

    2013-05-01

    Human motion analysis is a task of increasing importance in several modern application fields, such as in medicine, avionics, security, and disaster recovery. In this paper, the use of Hough transform is considered and discussed in the scenario of human motion analysis. In particular, the influence of some transform parameters is investigated with the aim of improving Hough transform set-up when used in a measurement approach for human motion analysis. To this purpose, Hough transform has been applied to a set of results obtained by exploiting a suitable measurement system developed by the same authors, in the specific case of ultrasound waves. Such results have been obtained by using some reference images in the form of spectrograms achieved by using the system along with a purposely developed reference target emulating some human body movements. The results show that the considered measurement system, and more generally the human motion analysis and detection system, can be optimized by a proper set-up and use of Hough transform algorithm.

  15. Quantification of stiffness measurement errors in resonant ultrasound spectroscopy of human cortical bone.

    Science.gov (United States)

    Cai, Xiran; Peralta, Laura; Gouttenoire, Pierre-Jean; Olivier, Cécile; Peyrin, Françoise; Laugier, Pascal; Grimal, Quentin

    2017-11-01

    Resonant ultrasound spectroscopy (RUS) is the state-of-the-art method used to investigate the elastic properties of anisotropic solids. Recently, RUS was applied to measure human cortical bone, an anisotropic material with low Q-factor (20), which is challenging due to the difficulty in retrieving resonant frequencies. Determining the precision of the estimated stiffness constants is not straightforward because RUS is an indirect method involving minimizing the distance between measured and calculated resonant frequencies using a model. This work was motivated by the need to quantify the errors on stiffness constants due to different error sources in RUS, including uncertainties on the resonant frequencies and specimen dimensions and imperfect rectangular parallelepiped (RP) specimen geometry. The errors were first investigated using Monte Carlo simulations with typical uncertainty values of experimentally measured resonant frequencies and dimensions assuming a perfect RP geometry. Second, the exact specimen geometry of a set of bone specimens were recorded by synchrotron radiation micro-computed tomography. Then, a "virtual" RUS experiment is proposed to quantify the errors induced by imperfect geometry. Results show that for a bone specimen of ∼1° perpendicularity and parallelism errors, an accuracy of a few percent ( <6.2%) for all the stiffness constants and engineering moduli is achievable.

  16. Ultrasound measurements of umbilical cord transverse area in normal pregnancies and pregnancies complicated by diabetes mellitus.

    Science.gov (United States)

    Pietrygal, Marek; Brazert, Jacek; Wender-Ozegowskal, Ewa; Zawiejska, Agnieszka; Brazert, Maciej; Dubiel, Mariusz; Gudmundsson, Saemundur

    2014-11-01

    A voluminous umbilical cord has been described in diabetic pregnancies. The aim of this studywas to see if measurements of cord diameters might be of value in the evaluation of diabetic pregnancies and especially those suspected of a large for gestational age (LGA) fetus. In an observational, prospective study umbilical cord areas and vessel diameters were measured between gestational age of 22 and 40 weeks in transverse ultrasound images of the central part of the cord in 141 normal and 135 diabetic pregnancies of which 30 were suspected of being LGA. Wharton's jelly area was calculated by subtracting the vessel area from the total transverse cord area. Normal reference curves were constructed for gestational age. Umbilical cord and Wharton's jelly areas increased with gestation. The vessel area leveled out at 32-33 weeks of gestation and the umbilical vein area decreased after 36 weeks of gestation. The umbilical cord parameters in diabetic pregnancies did not differ from controls. Cord areas were enlarged in 1/3 of the LGA fetuses. Umbilical cord area measurements are of limited value for the evaluation of diabetic pregnancies suspected having a LGA-fetus.

  17. Improved accuracy of ultrasound-guided therapies using electromagnetic tracking: in-vivo speed of sound measurements

    Science.gov (United States)

    Samboju, Vishal; Adams, Matthew; Salgaonkar, Vasant; Diederich, Chris J.; Cunha, J. Adam M.

    2017-02-01

    The speed of sound (SOS) for ultrasound devices used for imaging soft tissue is often calibrated to water, 1540 m/s1 , despite in-vivo soft tissue SOS varying from 1450 to 1613 m/s2 . Images acquired with 1540 m/s and used in conjunction with stereotactic external coordinate systems can thus result in displacement errors of several millimeters. Ultrasound imaging systems are routinely used to guide interventional thermal ablation and cryoablation devices, or radiation sources for brachytherapy3 . Brachytherapy uses small radioactive pellets, inserted interstitially with needles under ultrasound guidance, to eradicate cancerous tissue4 . Since the radiation dose diminishes with distance from the pellet as 1/r2 , imaging uncertainty of a few millimeters can result in significant erroneous dose delivery5,6. Likewise, modeling of power deposition and thermal dose accumulations from ablative sources are also prone to errors due to placement offsets from SOS errors7 . This work presents a method of mitigating needle placement error due to SOS variances without the need of ionizing radiation2,8. We demonstrate the effects of changes in dosimetry in a prostate brachytherapy environment due to patientspecific SOS variances and the ability to mitigate dose delivery uncertainty. Electromagnetic (EM) sensors embedded in the brachytherapy ultrasound system provide information regarding 3D position and orientation of the ultrasound array. Algorithms using data from these two modalities are used to correct bmode images to account for SOS errors. While ultrasound localization resulted in >3 mm displacements, EM resolution was verified to <1 mm precision using custom-built phantoms with various SOS, showing 1% accuracy in SOS measurement.

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  19. The influence of steel roughness and granulation on the accuracy of part thickness measurement by means of ultrasounds

    Science.gov (United States)

    Sontea, S.; Baltanoiu, M.

    1974-01-01

    Nondestructive measurement of the thickness of one-sided parts can be successfully conducted with the aid of ultrasounds. Using an ultrasonic defectoscope equipped with a highly precise device for thickness measurement, the experimental results obtained and the parameters that influence them are discussed. It is known that the manner of attaching the probe to the surface to be tested is influenced by the roughness of the surface. Likewise, in view of the fact that measurement results are influenced by the velocity of ultrasounds in the material to be investigated, they are also conditioned by the size of the structure. These factors and the manner in which they influence measurement results are also described.

  20. FD-OCT and IVUS intravascular imaging modalities in peripheral vasculature.

    Science.gov (United States)

    Spiliopoulos, S; Kitrou, P; Katsanos, K; Karnabatidis, D

    2017-02-01

    Intra-Vascular Ultra-Sound (IVUS) and Frequency Domain-Optical Coherence Tomography (FD-OCT), in vivo, intra-vascular, imaging modalities, widely used in the field of coronary disease, have been recently implemented in peripheral endovascular procedures, for procedural assessment, plaque characterization and determination of predictors of treatment outcomes. Their unique characteristics have also been used in order to provide additional features and improve the performance of re-entry devices and atherotomes. Areas covered: Present review focuses on available literature regarding these two promising imaging technologies in the peripheral vasculature, highlighting the added value produced by their use in endovascular therapy, their limitations and their utilization in new endovascular devices. Authors also provide their future perspective and the possible benefits in understanding vascular behavior and lesion characterization in peripheral endovascular interventions. Expert commentary: By providing both quantitative but also qualitative data on vessel and lesion morphology, intravascular imaging modalities offer a valid solution for endovascular treatment evaluation and outcome presentation homogeneity.

  1. Measurement and numerical simulation of high intensity focused ultrasound field in water

    Science.gov (United States)

    Lee, Kang Il

    2017-11-01

    In the present study, the acoustic field of a high intensity focused ultrasound (HIFU) transducer in water was measured by using a commercially available needle hydrophone intended for HIFU use. To validate the results of hydrophone measurements, numerical simulations of HIFU fields were performed by integrating the axisymmetric Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation from the frequency-domain perspective with the help of a MATLAB-based software package developed for HIFU simulation. Quantitative values for the focal waveforms, the peak pressures, and the size of the focal spot were obtained in various regimes of linear, quasilinear, and nonlinear propagation up to the source pressure levels when the shock front was formed in the waveform. The numerical results with the HIFU simulator solving the KZK equation were compared with the experimental data and found to be in good agreement. This confirms that the numerical simulation based on the KZK equation is capable of capturing the nonlinear pressure field of therapeutic HIFU transducers well enough to make it suitable for HIFU treatment planning.

  2. Utility of common bile duct measurement in emergency department point of care ultrasound: A prospective study.

    Science.gov (United States)

    Lahham, Shadi; Becker, Brent A; Gari, Abdulatif; Bunch, Steven; Alvarado, Maili; Anderson, Craig L; Viquez, Eric; Spann, Sophia C; Fox, John C

    2017-11-18

    Measurement of the common bile duct (CBD) is considered a fundamental component of biliary point-of-care ultrasound (POCUS), but can be technically challenging. The primary objective of this study was to determine whether CBD diameter contributes to the diagnosis of complicated biliary pathology in emergency department (ED) patients with normal laboratory values and no abnormal biliary POCUS findings aside from cholelithiasis. We performed a prospective, observational study of adult ED patients undergoing POCUS of the right upper quadrant (RUQ) and serum laboratory studies for suspected biliary pathology. The primary outcome was complicated biliary pathology occurring in the setting of normal laboratory values and a POCUS demonstrating the absence of gallbladder wall thickening (GWT), pericholecystic fluid (PCF) and sonographic Murphy's sign (SMS). The association between CBD dilation and complicated biliary pathology was assessed using logistic regression to control for other factors, including laboratory findings, cholelithiasis and other sonographic abnormalities. A total of 158 patients were included in the study. 76 (48.1%) received non-biliary diagnoses and 82 (51.9%) were diagnosed with biliary pathology. Complicated biliary pathology was diagnosed in 39 patients. Sensitivity of CBD dilation for complicated biliary pathology was 23.7% and specificity was 77.9%. Of patients diagnosed with biliary pathology, none had isolated CBD dilatation. In the absence of abnormal laboratory values and GWT, PCF or SMS on POCUS, obtaining a CBD measurement is unlikely to contribute to the evaluation of this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Inverse problem in anisotropic poroelasticity: drained constants from undrained ultrasound measurements.

    Science.gov (United States)

    Berryman, James G; Nakagawa, Seiji

    2010-02-01

    Poroelastic analysis has traditionally focused on the relationship between dry and drained constants, which are assumed known, and the saturated or undrained constants, which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the effects of the fluids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore fluid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  4. Inverse problem in anisotropic poroelasticity: Drained constants from undrained ultrasound measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berryman, J.G.; Nakagawa, S.

    2009-11-20

    Poroelastic analysis has traditionally focused on the relationship between dry or drained constants which are assumed known and the saturated or undrained constants which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the eects of the uids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore uid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  5. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Directory of Open Access Journals (Sweden)

    Chen Jen Shan

    2014-04-01

    Full Text Available PurposeWe developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US and computerized tomography (CT for needle´s entry angle calculation and to study factors that may interfere in this procedure.Materials and MethodsHeight, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD and ventral decubitus (VD, and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI.ResultsBMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001, whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI.ConclusionSCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined.

  6. Quantitative head ultrasound measurements to determine thresholds for preterm neonates requiring interventional therapies following intraventricular hemorrhage

    Science.gov (United States)

    Kishimoto, Jessica; Fenster, Aaron; Salehi, Fateme; Romano, Walter; Lee, David S. C.; de Ribaupierre, Sandrine

    2016-04-01

    Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.

  7. Transabdominal ultrasound measurement of rectal diameter is dependent on time to defecation in constipated children

    DEFF Research Database (Denmark)

    Modin, Line; Dalby, Kasper; Walsted, Anne-Mette

    2015-01-01

    AIM: To study whether diurnal variations and time in relation to defecation has to be taken into account when measurements of rectal diameter are used to determine faecal impaction in constipated children. METHODS: Repeated ultrasound measures of rectal diameter were performed in 28 children (14...... constipated/14 healthy, aged between 4 and 12 years) every third hour during 24 h. After defecation, three additional scans were performed at 1-h intervals. RESULTS: No diurnal variation in rectal diameter was found in the healthy group. In the constipated group, mean rectal diameter was significantly larger...... at 2 pm (P = 0.038) and 5 pm (P = 0.006). There were significant differences between rectal diameter in the healthy group and the constipated group at 2 pm (P = 0.016) and 5 pm (P = 0.027). When we omitted the rectal diameter of five constipated children who had their first bowel movement after 5 pm...

  8. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  9. Utilization of an ultrasound beam steering angle for measurements of tissue displacement vector and lateral displacement

    Directory of Open Access Journals (Sweden)

    Chikayoshi Sumi

    2010-09-01

    Full Text Available Chikayoshi SumiDepartment of Information and Communication Sciences, Faculty of Science and Technology, Sophia University, Tokyo, JapanAbstract: A number of ultrasonic displacement/velocity measurement methods have been extensively developed for measurements of blood flow, tissue motion, and strain. Lateral modulation (LM methods have also been reported using steered, crossed beams, and these methods permit measurements of displacement vectors. In this report, a new beam steering method for the transmission and reception of ultrasound is proposed, which can enable measurements of lateral displacements and of arbitrary displacement vectors with a very high degree of accuracy. Because this beam steering method uses only a steering angle, this method is referred to as ASTA. With ASTA, the number of available methods to obtain a displacement vector measurement is limited to previously developed block-matching methods, such as the multidimensional cross-spectrum phase gradient method, and the multidimensional autocorrelation method (MAM and the multidimensional Doppler method (MDM using a block-matching method (the methods using block matching are referred to as MAMb and MDMb, respectively. Being dependent on the measurement method, only a lateral displacement measurement can be made even if the methods are multidimensional, ie, previously developed MAM and MDM using a moving average and a mirror setting of the obtained steered beams, and one-dimensional (1D, such as an autocorrelation method. Considerations of beamforming schemes using LM and ASTA show that the simple ASTA beamforming method increases capabilities for real-time measurements and requires a small physical aperture when compared with LM. For lateral displacement measurements (eg, blood flow in a carotid artery, a lateral coordinate must correspond to the direction of the target’s lateral motion, and the steering angle used is as large as possible to increase the measurement accuracy

  10. Optical fiber laser ultrasound transmitter with electrospun composite for minimally invasive medical imaging

    Science.gov (United States)

    Poduval, Radhika; Noimark, Sacha; Colchester, Richard; Macdonald, Tom; Parkin, Ivan; Desjardins, Adrien; Papakonstantinou, Ioannis

    2017-07-01

    We report an optical fiber ultrasound transmitter with electrospun MWCNT-polymer composite, generating high-amplitude broadband ultrasound. They produced pressures in the range of conventional intravascular imaging transducers, and can be incorporated into catheters/needles for keyhole surgery

  11. Measurement of Post Void Residual Urine Volume Using Portable 3D Ultrasound Compared with Urinary Catheterization

    Directory of Open Access Journals (Sweden)

    Pichai Leerasiri

    2017-05-01

    Full Text Available Objective: To find out correlation between the 3D ultrasound and conventional urethral catheterization in terms of measurement accuracy of post void residual urine (PVR volume, pain score, and elapsed time among patients attending Urogynecology Clinic, Siriraj Hospital between December 2011 to December 2012. Methods: With the approval of the institution’s Ethics Committees, a total of 64 participants were enrolled. Participants with conditions that could affect bladder volume, including previous pelvic surgery and radiation, abnormal anatomy of genitourinary system, and contraindications for urethral catheterization were excluded. A questionnaire asking about demographic data and clinical presentation of each participant was completed. PVR volume was measured using the BladderScan® (BVI-9400, followed by urethral catheterization. Differences between PVR volume and elapsed time in both procedures were determined. At the end of each procedure every participant was asked to rate the pain score, from 0 (no pain to 10 (most severe pain, according to the Visual Analog Scale. Results: The mean age was 60 years old, ranging from 33 to 81. The mean body mass index (BMI was 26.5 kg/m2± 4.1. The PVR volume measured by the BladderScan® was significantly correlated with that measured by the conventional catheterization with the correlation coefficient of 0.92 (p<0.001. The mean pain score in the BladderScan® group was obviously less when compared with that of the catheterization group (0.59 ± 1.19 vs 3.00 ± 2.07; p<0.001. The mean time used in the BladderScan® group was significantly lower than that in the catheterization group. Conclusion: The BladderScan® had high correlation, time saving and less pain compared to conventional urethral catheterization for measurement of the post-void residual urine volume.

  12. Reliability of ultrasound imaging for the measurement of abdominal muscle thickness in typically developing children

    Directory of Open Access Journals (Sweden)

    M. Unger

    2010-01-01

    Full Text Available Introduction: A bdominal muscles are key to both posture andgait in both children with typical development (TD and with disabilities.Ultrasound (US imaging is a potential non-invasive method for investigatingactivity in these muscles. This study therefore aimed to determine the inter-tester and intra-tester reliability of B-mode US for investigating transverseabdominus (TrA , rectus abdominus (RA and external- (EO and internaloblique (IO muscle activity in children with TD. Design: A  prospective cor-relational descriptive study.  Participants:  Eighty six, 6-13year old children from one private and one public mainstream school. Outcome measures: Two sets of B-mode US images where captured per subject during rest and during head-up, resisted head-up and resisted sling activities. Intra-class Correlation Coefficients (ICC and standard error of measurement (SEM were used to analyse the data. Results: Good correlation was found for both test - retest condi-tions for all four muscles tested during rest: 0.91(TrA ; 0.90(IO; 0.91(EO; 0.94(RA for intra-tester reliability and0.74(TrA ; 0.88(IO; 0.74(EO; 0.83(RA for inter-tester reliability. Repeatability of thickness measures during activity however showed variation in recruitment patterns. A  significant correlation was found between age and BMI andresting abdominal muscle thickness (p<0.001. Conclusion: The study supports the reliability of US measurement of resting abdominal muscles and of the RA  under active conditions in children aged six to 13. However the stability o measurement of the other muscles under active conditions still needs to be established.

  13. Measurement of Anterior–Posterior Diameter of Ivc By Ultrasonography: a Non Invasive Method for Estimation of Central Venous Pressure.

    Directory of Open Access Journals (Sweden)

    N Nouri-Majalan

    2007-04-01

    Full Text Available Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intravascular volume status. The purpose of this study was to compare the results of IVC diameter measurement by ultrasonography and CVP measurement for calculating the intravascular volume in ICU admitted patients. Methods: This was a descriptive and prospective study including 50 patients admitted in ICU with a central venous catheter placed for any reason whatsoever and no signs of increased right atrial pressure. CVP was measured in supine position by CVP manometer. The anterior- posterior IVC diameter was assessed by ultrasonography during inspiration and expiration. Data analysis was performed by SPSS and evaluated statistically with Pearsons regression and linear correlation test. Results: The mean CVP at inspiration and during expiration was 11.35+ 5.53, 12.20 + 5.65 cmH2O, respectively. The mean of inspiratory and expiratory IVC diameter was 7.71 + 3.5 , 11.37 + 3.28 mm, respectively. There was significant correlation between CVP and IVC diameter both during inspiration (r= 0.64 , p-value= 0.001 and expiration (r=0.495 , p-value=0.001 Conclusion: The result of this study suggests that IVC diameter measurement by ultrasound can be used as a reliable and non- invasive method for estimating the intravascular volume.

  14. Reproducibility of ultrasound measurement of transversus abdominis during loaded, functional tasks in asymptomatic young adults.

    Science.gov (United States)

    McPherson, Sue L; Watson, Todd

    2012-06-01

    To examine the reproducibility of repeat tests of ultrasound imaging (USI) measurement of transversus abdominis (TrA) activation in a single group of asymptomatic adults performing reaching and lifting tasks before and after abdominal drawing-in technique (ADIM) training in the supine position with TrA USI biofeedback. Clinical measurement, longitudinal reliability study. University laboratory. Five male (age, 20.6 ± 4.8 years; body mass index, 25.8 ± 4.5) and 8 female (age, 18.3 ± 0.5 years; body mass index, 24.4 ± 3.3) healthy college students. Not applicable. Reliability and precision of minimum, maximum, and percentage of change in TrA thickness measures were examined on recorded cine loop images obtained via USI (B-mode, 7.5 MHz) for 13 asymptomatic adults. Thickness changes of the TrA muscle were measured at rest and during contraction while performing 5 functional, loaded tasks on 3 repeat tests during 3 testing sessions (ie, before ADIM training and 5 minutes and 5 months after ADIM training). The percent thickness change of TrA was calculated as [(thickness(max) - thickness(min))/thickness(min)] × 100. Reproducibility was examined by using intraclass correlation coefficients (ICC(2,k)), standard error of measurement (error variance formula), and repeated-measures analysis of variance. Ranges of ICC and standard error of measurement values for 3 repeat tests per testing session were high and precise for single measures of minimum thickness per task (session 1: 0.68-0.93, 0.24-0.37 mm; session 2: 0.62-0.87, 0.28-0.44 mm; session 3: 0.79-0.84, 0.43-0.56 mm) and for composite measures of maximum thickness (session 1: 0.93, 0.25 mm; session 2: 0.94, 0.37 mm; session 3: 0.95, 0.64 mm) and percent change in thickness (session 1: 0.81, 12%; session 2: 0.94, 14%; session 3: 0.94, 15%). Repeated-measures analysis of variance indicated significant effects for subjects, but not repeat tests. This study produced acceptable reproducibility of USI measures of Tr

  15. ULTRASOUND MEASUREMENTS OF THE DISTANCE BETWEEN LIMBUS AND RETINAL BREAK IN EYES WITH MEDIA OPACITIES.

    Science.gov (United States)

    Vaiano, Agostino S; Coronado Quitllet, Elisabet; Zinzanella, Gaetano; De Benedetti, Giacomo; Caramello, Guido

    2017-07-01

    To assess the reproducibility and accuracy of ultrasound (US) measurements in determining the distance between corneoscleral limbus and retinal break and its relation with the distance measured by indirect ophthalmoscopy, in patients undergoing a laser retinopexy procedure. Forty-four patients with a single retinal break, scheduled for laser a retinopexy procedure (26 phakic patients and 18 pseudophakic patients), underwent 5 repeated measurements by high-resolution US and 3 measurements (at the time of the laser procedure, 1 and 3 months) by indirect ophthalmoscopy with scleral indentation of the corneoscleral limbus-retinal break distance with a caliper. In the phakic patients group, measurements ranged from 8.75 mm to 14.45 mm (12.56 ± 1.24, mean ± SD) and from 9.5 mm to 15 mm (12.35 ± 1.32) with US and indirect ophthalmoscopy, respectively. In the pseudophakic patients group, measurements ranged from 9.04 mm to 13.95 mm (11.88 ± 1.33) and from 8.5 mm to 13.2 mm (11.93 ± 0.99) with US and indirect ophthalmoscopy, respectively. The correlation coefficient was greater than 0.97. Measurement variability was very small. In phakic eyes, it was 0.13 ± 0.08 mm and 0.13 ± 0.07 mm with US and indirect ophthalmoscopy, respectively. In pseudophakic eyes, it was 0.12 ± 0.05 mm and 0.14 ± 0.05 mm with US and indirect ophthalmoscopy, respectively. US and indirect ophthalmoscopy measurements were not statistically different (Student's t-test, P = 1.71). The analysis of the variance among phakic and pseudophakic patients confirmed that measurements of the two groups do not differ significantly (Fisher's exact test, P = 0.16). The univariate analysis showed no significant difference in both US and indirect ophthalmoscopy measurements (ANOVA, P = 0.09) and between the two types of measurements and patient groups (ANOVA, P = 0.38). This study suggests relevant accuracy and reliability of US readings and provides the possibility of using this technique for localizing tears

  16. Confiabilidade da medida de espessuras musculares pela ultrassonografia Reliability of muscle thickness measurements using ultrasound

    Directory of Open Access Journals (Sweden)

    Paulo Sergio Chagas Gomes

    2010-02-01

    Full Text Available OBJETIVO: Determinar a confiabilidade das medidas de espessuras dos músculos flexores e extensores do cotovelo e joelho pela ultrassonografia (US, quantificando o erro típico associado a essas medidas (ETM. MÉTODOS: A confiabilidade (duas medidas interdias foi determinada em 15 voluntários aparentemente saudáveis (oito mulheres, 33,9 ± 11,4 anos, 76 ± 21kg, 170 ± 10cm. As imagens da musculatura flexora (FC e extensora do cotovelo (EC e flexora (FJ e extensora do joelho (EJ foram obtidas pela US bidimensional no modo B, utilizando transdutor de 7,5MHz. As espessuras do tecido muscular compreendidas entre as interfaces com o osso e com o tecido adiposo foram medidas em sítios anatômicos identificados e registrados para ser repetidos na segunda medida. RESULTADOS: A ANOVA não identificou diferenças significativas entre as medidas repetidas. Os coeficientes de correlação intraclasse foram FC = 0,970, EC = 0,971, FJ = 0,555 e EJ = 0,929 (P PURPOSE: To determine the reliability of muscle thickness measurements of elbow and knee flexors and extensors using ultrasound, and to quantify the typical error associated to the measurements (TEM. METHODS: The test-retest reliability was determined in 15 apparently healthy volunteers (8 women, 34 ± 11 years, 76 ± 21 kg, 170 ± 10 cm. The images of elbow flexors (EF and extensors (EE and knee flexors (KF and extensors (KE were obtained using a two dimensional mode B ultrasound instrument with a 7.5 MHz transducer. Muscle thickness between the adipose tissue and bone interfaces were measured at anatomical landmarks previously identified and recorded to assure the exact site for the retest. RESULTS: ANOVA did not identify any significant differences between the repeated measurements. Intraclass correlation coefficients (ICC of each pair of measure were EF = 0.970, EE = 0.971, KF = 0.555 e KE = 0.929 (P < 0.05 for all. The coefficients of variation were 3.9 %, 6.1 %, 6.6 % e 4.6 %, and TEM 1.3 mm, 1

  17. Comparison of grey scale median (GSM) measurement in ultrasound images of human carotid plaques using two different softwares.

    Science.gov (United States)

    Östling, Gerd; Persson, Margaretha; Hedblad, Bo; Gonçalves, Isabel

    2013-11-01

    Grey scale median (GSM) measured on ultrasound images of carotid plaques has been used for several years now in research to find the vulnerable plaque. Centres have used different software and also different methods for GSM measurement. This has resulted in a wide range of GSM values and cut-off values for the detection of the vulnerable plaque. The aim of this study was to compare the values obtained with two different softwares, using different standardization methods, for the measurement of GSM on ultrasound images of carotid human plaques. GSM was measured with Adobe Photoshop(®) and with Artery Measurement System (AMS) on duplex ultrasound images of 100 consecutive medium- to large-sized carotid plaques of the Beta-blocker Cholesterol-lowering Asymptomatic Plaque Study (BCAPS). The mean values of GSM were 35·2 ± 19·3 and 55·8 ± 22·5 for Adobe Photoshop(®) and AMS, respectively. Mean difference was 20·45 (95% CI: 19·17-21·73). Although the absolute values of GSM differed, the agreement between the two measurements was good, correlation coefficient 0·95. A chi-square test revealed a kappa value of 0·68 when studying quartiles of GSM. The intra-observer variability was 1·9% for AMS and 2·5% for Adobe Photoshop. The difference between softwares and standardization methods must be taken into consideration when comparing studies. To avoid these problems, researcher should come to a consensus regarding software and standardization method for GSM measurement on ultrasound images of plaque in the arteries. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. Noninvasive measurement of acoustic field inside mother's uterus generated by ultrasound scanning

    Science.gov (United States)

    Antonets, V. A.; Kazakov, V. V.

    2015-07-01

    Sounds in the audible range arising in mother's uterus during conventional ultrasound scanning were recorded noninvasively for the first time. It was found that their level is comparable with the level of spoken language.

  19. In vivo ultrasound and biometric measurements predict the empty body chemical composition in Nellore cattle.

    Science.gov (United States)

    Castilhos, A M; Francisco, C L; Branco, R H; Bonilha, S F M; Mercadante, M E Z; Meirelles, P R L; Pariz, C M; Jorge, A M

    2018-03-06

    Evaluation of the body chemical composition of beef cattle can only be measured postmortem and those data cannot be used in real production scenarios to adjust nutritional plans. The objective of this study was to develop multiple linear regression equations from in vivo measurements, such as ultrasound parameters [backfat thickness (uBFT, mm), rump fat thickness (uRF, mm), and ribeye area (uLMA, cm2)], shrunk body weight (SBW, kg), age (AG, d), hip height (HH, m), as well as from postmortem measurements (composition of the 9th to 11th rib section) to predict the empty body and carcass chemical composition for Nellore cattle. Thirty-three young bulls were used (339 ± 36.15 kg and 448 ± 17.78 d for initial weight and age, respectively). Empty body chemical composition (protein, fat, water, and ash in kg) was obtained by combining non-carcass and carcass components. Data were analyzed using the PROC REG procedure of SAS software. Mallows' Cp values were close to the ideal value of number of independent variables in the prediction equations plus one. Equations to predict chemical components of both empty body and carcass using in vivo measurements presented higher R2 values than those determined by postmortem measurements. Chemical composition of the empty body using in vivo measurements was predicted with R2 > 0.73. Equations to predict chemical composition of the carcass from in vivo measurements showed R2 lower (R2Chemical compounds from components of the empty body of Nellore cattle can be calculated by the following equations: Protein (kg) = 47.92 + 0.18 × SBW × 1.46 × uRF - 30.72 × HH (R2 = 0.94, RMSPE = 1.79); Fat (kg) = 11.33 + 0.16 × SBW + 2.09 × uRF - 0.06 × AG (R2 = 0.74, RMSPE = 4.18); Water (kg) = 34.00 + 0.55 × SBW + 0.10 × AG 2.34 × uRF (R2 = 0.96, RMSPE = 5.47). In conclusion, the coefficients of determination (for determining the chemical composition of the empty body) of the equations derived from in vivo measures were higher than those

  20. Obstetrical Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures of ... What are the limitations of Obstetrical Ultrasound Imaging? Obstetric ultrasound cannot identify all fetal abnormalities. Consequently, when ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  5. Detection and measurement of fetal abdominal contour in ultrasound images via local phase information and iterative randomized Hough transform.

    Science.gov (United States)

    Wang, Weiming; Qin, Jing; Zhu, Lei; Ni, Dong; Chui, Yim-Pan; Heng, Pheng-Ann

    2014-01-01

    Due to the characteristic artifacts of ultrasound images, e.g., speckle noise, shadows and intensity inhomogeneity, traditional intensity-based methods usually have limited success on the segmentation of fetal abdominal contour. This paper presents a novel approach to detect and measure the abdominal contour from fetal ultrasound images in two steps. First, a local phase-based measure called multiscale feature asymmetry (MSFA) is de ned from the monogenic signal to detect the boundaries of fetal abdomen. The MSFA measure is intensity invariant and provides an absolute measurement for the signi cance of features in the image. Second, in order to detect the ellipse that ts to the abdominal contour, the iterative randomized Hough transform is employed to exclude the interferences of the inner boundaries, after which the detected ellipse gradually converges to the outer boundaries of the abdomen. Experimental results in clinical ultrasound images demonstrate the high agreement between our approach and manual approach on the measurement of abdominal circumference (mean sign difference is 0.42% and correlation coef cient is 0.9973), which indicates that the proposed approach can be used as a reliable and accurate tool for obstetrical care and diagnosis.

  6. Ultrasound measurement of the size of the anterior tibial muscle group: the effect of exercise and leg dominance

    LENUS (Irish Health Repository)

    McCreesh, Karen

    2011-09-13

    Abstract Background Knowledge of normal muscle characteristics is crucial in planning rehabilitation programmes for injured athletes. There is a high incidence of ankle and anterior tibial symptoms in football players, however little is known about the effect of limb dominance on the anterior tibial muscle group (ATMG). The purpose of this study was to assess the effect of limb dominance and sports-specific activity on ATMG thickness in Gaelic footballers and non-football playing controls using ultrasound measurements, and to compare results from transverse and longitudinal scans. Methods Bilateral ultrasound scans were taken to assess the ATMG size in 10 Gaelic footballers and 10 sedentary controls (age range 18-25 yrs), using a previously published protocol. Both transverse and longitudinal images were taken. Muscle thickness measurements were carried out blind to group and side of dominance, using the Image-J programme. Results Muscle thickness on the dominant leg was significantly greater than the non-dominant leg in the footballers with a mean difference of 7.3%, while there was no significant dominance effect in the controls (p < 0.05). There was no significant difference between the measurements from transverse or longitudinal scans. Conclusions A significant dominance effect exists in ATMG size in this group of Gaelic footballers, likely attributable to the kicking action involved in the sport. This should be taken into account when rehabilitating footballers with anterior tibial pathology. Ultrasound is a reliable tool to measure ATMG thickness, and measurement may be taken in transverse or longitudinal section.

  7. INTRAVASCULAR ENDOTHELIOMA (ENDOTHELIOMA IN SITU, SYSTEMIC ENDOTHELIOMATOSIS).

    Science.gov (United States)

    HABER, H; HARRIS-JONES, J N; WELLS, A L

    1964-11-01

    A woman aged 48 years was found to be suffering from intravascular endothelioma. The initial clinical presentation was the presence of red, painless swellings in the skin of the lower limbs. The other clinical features, and the histological changes in skin biopsies, are described and compared with those in the two previously reported patients. It is suggested that the condition is analogous to the pre-invasive carcinomatous states.

  8. Doppler ultrasound measurement of resistance index in the diagnosis of prostate cancer.

    Science.gov (United States)

    Huang, Wei; Cen, Son; Kang, Xin-Li; Wang, Wei Fu; Wang, Yang; Chen, Xiang

    2015-01-01

    Prostate cancer (PCa) remains the second leading cause of cancer diagnosis worldwide. Early diagnosis and treatment of PCa is critical since the long-term prognosis is excellent in patients with tumors confined to the prostate gland. The current meta-analysis investigates the diagnostic value of resistive index (RI) measurement using color Doppler ultrasound in patients with PCa. Electronic literature databases were exhaustively searched for relevant studies published prior to May 31, 2014. Nine studies met our predetermined inclusion criteria for the present meta-analysis. The methodologic quality of the selected studies was independently assessed by 2 reviewers based on Quality Assessment of Diagnostic Accuracy Studies tool. Our meta-analysis results showed that RI values were significantly higher in malignant prostate tissues compared to normal prostate tissues (standardized mean difference [SMD] 0.42, 95% confidence interval [CI] 0.12~0.73, p = 0.007) and benign prostate tissues (SMD 0.41, 95% CI 0.26~0.56, pbased on the diagnostic instruments used revealed that RI values were accurate in diagnosis of PCa when compared between malignant tissue vs normal tissue and malignant tissue vs benign tissue (all pvalues in diagnosis of PCa.

  9. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  10. Reliability of the ultrasound measurements of abdominal muscles activity when activated with and without pelvic floor muscles contraction.

    Science.gov (United States)

    Tahan, Nahid; Rasouli, Omid; Arab, Amir Massoud; Khademi, Khosro; Samani, Elham Neisani

    2014-01-01

    Synergistic co-activation of the abdominal and pelvic floor muscles (PFM) has been shown in literature. Some studies have assessed the reliability of ultrasound measures of the abdominal muscles. The aim of this study was to determine the reliability of ultrasound measurements of transverses abdominis (TrA) and obliquus internus (OI) muscles during different conditions (PFM contraction, abdominal hollowing manoeuvre (AHM) with and without PFM contraction) in participants with and without chronic low back pain (LBP). 21 participants (9 with LBP, 12 healthy) participated in the study. The reliability of thickness measurements at rest and during each condition and thickness changes and percentage of this changes at different conditions were assessed. The results showed high reliability of the thickness measurement at rest and during each condition of TrA and OI muscles, moderate to substantial reliability for the thickness change and percentage of thickness change of TrA, and fair to moderate reliability of the thickness change and percentage of thickness change of OI in both groups. Ultrasound imaging can be used as a reliable method for assessment of abdominal muscle activity with and without PFM contraction.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... BPH) , with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician ...

  12. Comparison of Central Corneal Thickness Measurements Obtained by RTVue OCT, Lenstar, Sirius Topography, and Ultrasound Pachymetry in Healthy Subjects.

    Science.gov (United States)

    Şimşek, Ali; Bilak, Şemsettin; Güler, Mete; Çapkin, Musa; Bilgin, Burak; Reyhan, Ali Hakim

    2016-01-01

    To compare central corneal thickness (CCT) measurement results obtained by RTVue OCT, Lenstar, Sirius topography, and ultrasound pachymetry (UP) (OcuScan RxP Ophthalmic Ultrasound System, Alcon Laboratories) in healthy subjects. 256 eyes of 128 healthy subjects were included in the study. CCT measurements were obtained from the eyes for each subject using the UP, Lenstar, Sirius topography, and RTVue OCT instruments. Ultrasound pachymetry measurements were performed after the eyes were anesthetized with one drop of 0.5% proparacaine hydrochloride and were performed at the same day after 15 minutes after previous measurements. Of 128 participants, 84 were male and 44 were female with a mean age of 33.15 ± 12.95 years (ranging from 18 to 75 years). The mean CCTs for UP, Lenstar, Sirius topography, and RTVue OCT were 535.60 ± 35.15 (440,00-668,00); 532.63 ± 34.44 (449,00-650,00); 526.05 ± 36.45 (314,00-640,00); 525.89 ± 33.21 (437,00-646,00) µm, respectively. The mean CCT measurements were statistically different among the three groups (p = 0.002). CCT measurements obtained using RTVue-OCT were significantly thinner than those obtained using UP (p = 0.009). Sirius CCT measurements were also thinner than UP (p = 0.011). Mean CCT measurements between UP and Lenstar were similar (p = 0.769). Measurements with Lenstar (r = 0.849), Sirius topography (r = 0.883), and RTVue OCT (0.949) were highly correlated with UP measurements. RTVue OCT and Sirius topography significantly underestimated the CCT compared with UP. Although highly correlated, the measurement values with these devices are not directly interchangeable in clinical practice.

  13. Ultrasound for Drug and Gene Delivery to the Brain

    OpenAIRE

    Hynynen, Kullervo

    2008-01-01

    Noninvasive, transient, and local image-guided blood-brain barrier disruption (BBBD) has been demonstrated with focused ultrasound exposure in animal models. Most studies have combined low pressure amplitude and low time average acoustic power burst sonications with intra-vascular injection of pre-formed micro-bubbles to produce BBBD without damage to the neurons. The BBB has been shown to be healed within a few hours after the exposure. The combination of focused ultrasound beams with MR ima...

  14. Performance and ultrasound measurements of beef cattle fed diets based on whole corn or oats grains

    Directory of Open Access Journals (Sweden)

    Hugo M Arelovich

    2013-09-01

    Full Text Available This study intended to contrast dietary effects of whole grain oats versus corn included in rations with moderate roughage content on animal performance, beef ultrasound measurements, rumen and blood parameters. Ten Aberdeen Angus steers (203 kg in individual pens were fed twice daily on either whole oats (OD or corn (CD based diets. Measurements were: DM intake (DMI, average daily gain (ADG, feed to gain ratio (F/G; back fat (BF and rib eye area (RA; blood parameters. Four cannulated steers were used to study rumen pH, NH3-N and grain degradability. Rations dietary components were 55% grain, 30.1% barley straw, and 10.6% whole soybeans. Despite calculated higher ME supply (P = 0.0887 no differences were found for DMI, ADG, or F/G. Metabolizable protein intake (19.4% was larger and degradable protein intake (43.3% smaller for CD compared with OD (P < 0.01. The growth rate (cm² d-1 for RA was 40% grater for OD, but larger BF deposition (P = 0.0787 was found for CD. Blood Mg was higher for OD (p = 0.0564, nevertheless other blood parameters remained unaffected. Rumen pH and NH3-N were not influenced by diet, variations were only observed within time periods. Rumen pH decreased linearly from 7.05 to 6.13 and 7.11 to 6.37 for OD and CD respectively (P < 0.05. Minimum NH3-N concentrations (mg dL-1 were reached 12 and 18 h after morning meal for OD (7.10 and CD (5.82 respectively. Rumen degradation was larger for oats than corn. Whole oats rather than corn fed up to 55% of total DM seems to improve protein deposition, without significant changes in animal performance, rumen environment or blood parameters.

  15. Membrane design of an all-optical ultrasound receiver

    NARCIS (Netherlands)

    Leinders, S.M.; Dongen, K.W.A. van; Jong, N. de; Verweij, M.D.; Westerveld, W.J.; Urbach, H.P.; Neer, P.L.M.J. van; Pozo Torres, J.M.

    2013-01-01

    Ultrasound sensors such as piezoelectric transducers and CMUTs are successfully used for medical imaging. However, especially wiring of individual elements is difficult in the fabrication of small piezoelectric arrays, used in, e.g. the field of intravascular imaging. As an alternative, we designed

  16. Estimation of femoral bone density from trabecular direct wave and cortical guided wave ultrasound velocities measured at the proximal femur in vivo

    DEFF Research Database (Denmark)

    Barkmann, Reinhard; Dencks, Stefanie; Bremer, Alexander

    2008-01-01

    and of guided waves through cortical bone could be used to estimate BMD. In two centres, Kiel and Odense, we measured time-of-flight (TOF) of waves through the trabecular greater trochanter and cortical intertrochanter as well as a wave through soft tissue only. TOF was adjusted for leg width using ultrasound......Bone mineral density (BMD) of the proximal femur is a predictor of hip fracture risk. We developed a Quantitative Ultrasound (QUS) scanner for measurements at this site with similar performance (FemUS). In this study we tested if ultrasound velocities of direct waves through trabecular bone...

  17. TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

    International Nuclear Information System (INIS)

    Zhang, Y; Stekel, S; Tradup, D; Hangiandreou, N

    2014-01-01

    Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax

  18. Vascular applications of contrast-enhanced ultrasound imaging.

    Science.gov (United States)

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf A; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  19. Uncertainty assessment in measurement of myotube thickness in cells culture treated with and without therapeutic ultrasound

    International Nuclear Information System (INIS)

    Abrunhosa, V M; Alvarenga, A V; Costa-Félix, R P B; Costa, M L; Mermelstein, C

    2015-01-01

    Effectiveness of an ultrasound treatment shall be assessed by experiments. A reliable cell culture protocol is available and spatial discrepancies could arise. To assure if the spatial difference are relevant or not, and how they should be dealt with, an uncertainty model for the treatment result is a metrological reliable solution. The present work reports a metrological approach to assess myotube thickness and to validate a primary cell culture of muscle after a therapeutic ultrasound treatment, comparing it with a control group. The results reinforced the importance of such approach and show an efficacy of treatment on myotube differentiation

  20. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... records tiny changes in the sound's pitch and direction. These signature waves are instantly measured and displayed ... ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as they move ...

  2. Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization?

    Directory of Open Access Journals (Sweden)

    Alistair Kent

    2015-01-01

    Full Text Available Introduction: Inferior vena cava collapsibility index (IVC-CI has been shown to correlate with both clinical and invasive assessment of intravascular volume status, but has important limitations such as the requirement for advanced sonographic skills, the degree of difficulty in obtaining those skills, and often challenging visualization of the IVC in the postoperative patient. The current study aims to explore the potential for using femoral (FV or internal jugular (IJV vein collapsibility as alternative sonographic options in the absence of adequate IVC visualization. Methods: A prospective, observational study comparing IVC-CI and Fem- and/or IJV-CI was performed in two intensive care units (ICU between January 2012 and April 2014. Concurrent M-mode measurements of IVC-CI and FV- and/or IJV-CI were collected during each sonographic session. Measurements of IVC were obtained using standard technique. IJV-CI and FV-CI were measured using high-frequency, linear array ultrasound probe placed in the corresponding anatomic areas. Paired data were analyzed using coefficient of correlation/determination and Bland-Altman determination of measurement bias. Results: We performed paired ultrasound examination of IVC-IJV (n = 39 and IVC-FV (n = 22, in 40 patients (mean age 54.1; 40% women. Both FV-CI and IJV-CI scans took less time to complete than IVC-CI scans (both, P < 0.02. Correlations between IVC-CI/FV-CI (R 2 = 0.41 and IVC-CI/IJV-CI (R 2 = 0.38 were weak. There was a mean -3.5% measurement bias between IVC-CI and IJV-CI, with trend toward overestimation for IJV-CI with increasing collapsibility. In contrast, FV-CI underestimated collapsibility by approximately 3.8% across the measured collapsibility range. Conclusion: Despite small measurement biases, correlations between IVC-CI and FV-/IJV-CI are weak. These results indicate that IJ-CI and FV-CI should not be used as a primary intravascular volume assessment tool for clinical decision support in

  3. Hypothesis: Disseminated Intravascular Inflammation as the Inflammatory Counterpart to Disseminated Intravascular Coagulation

    Science.gov (United States)

    Bull, Brian S.; Bull, Maureen H.

    1994-08-01

    We have identified a leukocyte activation syndrome that is occasionally associated with the transfusion of intraoperatively recovered erythrocytes. This syndrome appears to result from intravascular damage caused by leukocytes activated during the erythrocyte salvage process. We hypothesize that this syndrome is part of a larger disease grouping: disseminated intravascular inflammation (DII). DII is the analog of the coagulation disorder disseminated intravascular coagulation. In disseminated intravascular coagulation, the organ damage results from uncontrolled activation of the clotting pathway; in DII the damage is caused by leukocytes that have become activated by direct contact with bacteria or in rare instances-such as erythrocyte salvage-in the absence of bacteria and bacterial products. Recent studies of the hazards associated with intraoperative blood salvage indicate that activation of leukocytes can be achieved by exposure to activated platelets alone. If such activated leukocytes are reinfused along with the washed erythrocytes, widespread organ damage may result. The lung is the organ most severely affected by activated leukocytes. Adult respiratory distress syndrome is one outcome. It is likely that DII is a presently unrecognized pathophysiological process that complicates a variety of primary disease states and increases their lethality.

  4. Usefulness of high-frequency vascular ultrasound imaging and serum inflammatory markers to predict plaque rupture in patients with stable and unstable angina pectoris.

    Science.gov (United States)

    Chen, Wen Qiang; Zhang, Mei; Ji, Xiao Ping; Ding, Shi Fang; Zhao, Yu Xia; Chen, Yu Guo; Zhang, Cheng; Zhang, Yun

    2007-11-01

    It remains unclear what kind of morphologic and biochemical features best predict plaque rupture in patients with angina pectoris (AP). This study aimed to investigate whether combined high-frequency vascular ultrasound imaging and measurements of serum inflammatory biomarkers can predict coronary plaque ruptures in patients with AP. The study population consisted of 20 patients with stable AP and 40 patients with unstable AP. High-frequency vascular ultrasound imaging was performed in the 2 groups to measure intima-media thickness, the plaque acoustic density of the common carotid arteries, and the flow-mediated dilation of the brachial arteries. Serum lipid profile and inflammatory biomarkers were measured in all patients. Using intravascular ultrasound, a list of coronary imaging parameters was obtained. A multivariate logistic regression model was applied to calculate the odds ratio of each parameter to predict coronary plaque ruptures detected by intravascular ultrasound. Of 139 coronary artery plaques identified by intravascular ultrasound, 48 plaques (9 in stable AP and 39 in unstable AP) developed ruptures. Among measured parameters, the values of carotid intima-media thickness, coronary external elastic membrane area, plaque area, plaque burden, plaque eccentric index and remodeling index, serum high-sensitivity C-reactive protein, soluble intercellular adhesion molecule-1, and soluble vascular cell adhesion molecule-1 were significantly higher in unstable AP than in stable AP (p <0.05 to 0.01). Of these parameters, carotid intima-media thickness, serum high-sensitivity C-reactive protein, and the coronary remodeling index were found to be significant predictors of coronary plaque rupture, with odds ratios of 9.51 (95% confidence interval 1.29 to 21.81), 3.02 (95% confidence interval 1.01 to 7.65), and 0.01 (95% confidence interval 0.00 to 0.34), respectively. In conclusion, combined high-frequency ultrasound imaging of coronary and carotid arteries and

  5. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  6. Measuring derived acoustic power of an ultrasound surgical device in the linear and nonlinear operating modes.

    Science.gov (United States)

    Petosić, Antonio; Ivancević, Bojan; Svilar, Dragoljub

    2009-06-01

    The method for measuring derived acoustic power of an ultrasound point source in the form of a sonotrode tip has been considered in the free acoustic field, according to the IEC 61847 standard. The main objective of this work is measuring averaged pressure magnitude spatial distribution of an sonotrode tip in the free acoustic field conditions at different electrical excitation levels and calculation of the derived acoustic power at excitation frequency (f0 approximately 25 kHz). Finding the derived acoustic power of an ultrasonic surgical device in the strong cavitation regime of working, even in the considered laboratory conditions (anechoic pool), will enable better understanding of the biological effects on the tissue produced during operation with the considered device. The pressure magnitude spatial distribution is measured using B&K 8103 hydrophone connected with a B&K 2626 conditioning amplifier, digital storage oscilloscope LeCroy Waverunner 474, where pressure waveforms in the field points are recorded. Using MATLAB with DSP processing toolbox, averaged power spectrum density of recorded pressure signals in different field positions is calculated. The measured pressure magnitude spatial distributions are fitted with the appropriate theoretical models. In the linear operating mode, using the acoustic reciprocity principle, the sonotrode tip is theoretically described as radially oscillating sphere (ROS) and transversely oscillating sphere (TOS) in the vicinity of pressure release boundary. The measured pressure magnitude spatial distribution is fitted with theoretical curves, describing the pressure field of the considered theoretical models. The velocity and displacement magnitudes with derived acoustic power of equivalent theoretical sources are found, and the electroacoustic efficiency factor is calculated. When the transmitter is excited at higher electrical power levels, the displacement magnitude of sonotrode tip is increased, and nonlinear behaviour

  7. Hybrid Segmentation of Vessels and Automated Flow Measures in In-Vivo Ultrasound Imaging

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Martins, Bo; Hansen, Kristoffer Lindskov

    2016-01-01

    Vector Flow Imaging (VFI) has received an increasing attention in the scientific field of ultrasound, as it enables angle independent visualization of blood flow. VFI can be used in volume flow estimation, but a vessel segmentation is needed to make it fully automatic. A novel vessel segmentation...

  8. Intravascular haemolysis: a potential missed diagnosis.

    Science.gov (United States)

    Sinclair, David; Briston, Philip; Rutland, Emma

    2002-01-01

    Raised serum bilirubin is a common finding as part of a routine "liver function test" profile. This case describes a patient with a raised serum bilirubin that was eventually found to be caused by intravascular haemolysis. The tests that confirmed the cause were instigated by clinical biochemistry staff but not before the patient had undergone unnecessary invasive procedures and had the diagnosis delayed by some time. The case is a reminder to biochemistry and haematology laboratories and clinical staff to investigate the possibility of haemolysis as well as hepatitis and Gilbert's disease as a cause of an isolated raised bilirubin.

  9. Intravascular imaging with a storage phosphor detector

    Science.gov (United States)

    Shikhaliev, Polad M.; Petrek, Peter; Matthews, Kenneth L., II; Fritz, Shannon G.; Bujenovic, L. Steven; Xu, Tong

    2010-05-01

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm3 volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 µCi cm-3 activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm-2 were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360° circumference. Spatial resolution was 0

  10. Influence of coupling substances in the measurement of ultrasound velocity in stone materials

    Science.gov (United States)

    Giuzio, Beatrice; Alvarez de Buergo, Monica; Fort, Rafael; Masini, Nicola

    2015-04-01

    Ultrasonic (US) testing is widely applied in many fields (i.e. aviation, petrochemical, power engineering, construction and metallurgical industries). In the field of built cultural heritage and science conservation, US testing can provide the quality of the historic building materials (physic-mechanical properties), their heterogeneity/homogeinity and anisotropy, in terms of materials characterization, but also how deterioration processes can affect their quality (either after natural decay or simulation ageing tests in the laboratory). Moreover, US testing is a useful technique in evaluating the effectiveness of conservation and restoration techniques such as assessing the compatibility among original and restoration materials, identification of original quarries, and the success or not in the increase of a material cohesion when applying consolidating products. In order to obtain precise, real and reliable measurements, coupling substances between the material surface and the ultrasonic sensors are frequently used, to provide a proper contact between the transducer and the material, to assure the perfect transmission of the ultrasonic wave. Various coupling agents can be applied for this purpose. According to Wesolowski (2012), the choice of the coupling agent significantly affects the measurement of propagation velocity in material samples and, as a consequence, the US test results. In this paper, the effect of six coupling agents (medical gel used for ultrasonography, gel + parafilm, plasticine, honey, glicerine and a plastic material provided for ultrasound measurement by Panametrics) on ultrasonic measurements conducted on specific building materials is investigated on two different types of building stones (granite and dolostone from the area of Madrid, traditionally used in the construction of the built heritage, 4 stone specimens for each rock variety, 20 x 6 x 8 cm). Direct and indirect modes measuring were performed, the first one with the transducers

  11. Organochlorine Compounds and Ultrasound Measurements of Fetal Growth in the INMA Cohort (Spain).

    Science.gov (United States)

    Lopez-Espinosa, Maria-Jose; Murcia, Mario; Iñiguez, Carmen; Vizcaino, Esther; Costa, Olga; Fernández-Somoano, Ana; Basterrechea, Mikel; Lertxundi, Aitana; Guxens, Mònica; Gascon, Mireia; Goñi-Irigoyen, Fernando; Grimalt, Joan O; Tardón, Adonina; Ballester, Ferran

    2016-01-01

    Several studies have reported decreases in birth size associated with exposure to organochlorine compounds (OCs), but uncertainties remain regarding the critical windows of prenatal exposure and the effects on fetal body segments. We examined the relationship between prenatal OC concentrations and fetal anthropometry. We measured 4,4´-dichlorodiphenyldichloroethylene (4,4´-DDE), hexachlorobenzene (HCB), and polychlorinated biphenyl (PCB) congeners (138, 153, and 180) in 2,369 maternal and 1,140 cord serum samples in four Spanish cohorts (2003-2008). We used linear mixed models to obtain longitudinal growth curves for estimated fetal weight (EFW), abdominal circumference (AC), biparietal diameter (BPD), and femur length (FL) adjusted by parental and fetal characteristics. We calculated standard deviation (SD) scores of growth at 0-12, 12-20, and 20-34 weeks of gestation as well as size at gestational week 34 for the four parameters. We studied the association between OCs and the fetal outcomes by cohort-specific linear models and subsequent meta-analyses. PCBs were associated with a reduction in AC up to mid-pregnancy, and BPD and FL from gestational week 20 onward. An inverse association was also found between HCB and AC growth in early pregnancy. The reduction of these parameters ranged from -4% to -2% for a doubling in the OC concentrations. No association between 4,4´-DDE and fetal growth was observed. To our knowledge, this is the first study to report an association between prenatal exposure to some PCBs and HCB and fetal growth: AC during the first two trimesters of pregnancy, and BPD and FL later in pregnancy. Lopez-Espinosa MJ, Murcia M, Iñiguez C, Vizcaino E, Costa O, Fernández-Somoano A, Basterrechea M, Lertxundi A, Guxens M, Gascon M, Goñi-Irigoyen F, Grimalt JO, Tardón A, Ballester F. 2016. Organochlorine compounds and ultrasound measurements of fetal growth in the INMA cohort (Spain). Environ Health Perspect 124:157-163; http://dx.doi.org/10

  12. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  13. Role of informed consent for intravascular contrast media

    International Nuclear Information System (INIS)

    Hopper, K.D.; Tyler, H.N. Jr.

    1988-01-01

    To evaluate the usefulness of different degrees of informed consent for intravascular contrast media, the authors divided 100 patients into four groups: (1) informed consent with no information on intravascular contrast media, (2) simple written informed consent that detailed common risks, (3) detailed written informed consent that detailed all known risks, and (4) MD informed consent, during which a radiologist discussed all known risks of intravascular contrast media. Physician counseling time for group 4 averaged 11.4 minutes. On a postprocedure test about the common complications and risk factors of intravascular contrast media, the average scores were: group 1, 38.4%; group 2, 68.2%; group 3, 63.2%; and group 4, 69.8%. There was no statistical difference between groups 2-4 on the postprocedure test. If informed consent is to be used prior to intravascular contrast media administration, a simple written consent detailing the common risks and risk factors appears to be the best method

  14. Effects of posture and anatomical location on inter-recti distance measured using ultrasound imaging in parous women.

    Science.gov (United States)

    Gillard, S; Ryan, C G; Stokes, M; Warner, M; Dixon, J

    2018-04-01

    Cross-sectional repeated measures. To quantify the effects of posture and measurement site on the inter-recti distance (IRD) and investigate the reliability of IRD measurement using ultrasound imaging in different postures. The linea alba connects the rectus abdominis muscles anteriorly and the width is known as the IRD. The IRD is usually measured in crook-lying and is the primary outcome measure to assess for a divarication of recti abdominis (DRA). The effects of posture and measurement site on the IRD have not been investigated. Ultrasound imaging was used to measure IRD in 41 women ≥8 weeks postpartum. The IRD was measured at three sites (superior-umbilicus, umbilicus and inferior-umbilicus), in three postures (crook-lying, sitting and standing), and repeated one-week later. The effects of posture and site were investigated using one-way ANOVAs. Reliability was analysed using Intraclass correlation coefficients (ICCs), Bland Altman analyses, standard error of measurement and minimal detectable change. The IRD was wider when standing vs. lying at both the superior-umbilicus and umbilicus by 0.30 cm (95% CI 0.21 to 0.39) and 0.20 cm (0.11-0.30) respectively (p < 0.001). Measurements at the inferior-umbilicus were, on average, 1.6 and 2.1 cm narrower than superior-umbilicus and umbilicus sites, respectively (p < 0.001). There was high intra-rater reliability within-session (ICC 3.3 ) and between-session (ICC 3.1 ) at all sites measured. The IRD can be measured reliably at all sites and postures. The IRD is wider at superior-umbilicus and umbilicus when upright compared with lying. There is a difference in IRD between all sites measured. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound is most often performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams ... to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . Ultrasound ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... What are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? In ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... What are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is ... in front of the rectum. top of page What are some common uses of the procedure? A ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  4. Computational evaluation of the compositional factors in fracture healing affecting ultrasound axial transmission measurements.

    Science.gov (United States)

    Machado, Christiano Bittencourt; de Albuquerque Pereira, Wagner Coelho; Talmant, Maryline; Padilla, Frédéric; Laugier, Pascal

    2010-08-01

    This work aimed at computationally evaluating the compositional factors in fracture healing affecting ultrasound axial transmission (UAT), using four numerical daily-changing healing models, representing more realistic clinical conditions. Using two-dimensional (2-D) simulations, a 1-MHz source and a receiver were positioned parallel to the bone surface to detect the first arriving signal (FAS). The time-of-flight of the FAS (TOF(FAS)) was found to be sensitive only to superficial modifications in the propagation path. It was also shown that callus mature bone better explained alone the variation in TOF(FAS) (R(2) >or= 0.70, p consolidation delays and nonunions. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  6. Protection against high intravascular pressure in giraffe legs.

    Science.gov (United States)

    Petersen, Karin K; Hørlyck, Arne; Ostergaard, Kristine H; Andresen, Joergen; Broegger, Torbjoern; Skovgaard, Nini; Telinius, Niklas; Laher, Ismael; Bertelsen, Mads F; Grøndahl, Carsten; Smerup, Morten; Secher, Niels H; Brøndum, Emil; Hasenkam, John M; Wang, Tobias; Baandrup, Ulrik; Aalkjaer, Christian

    2013-11-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along the artery. Histology of the isolated median artery confirmed dense sympathetic innervation at the narrowing. Structure and contractility of small arteries from muscular beds in the leg and neck were compared. The arteries from the legs demonstrated an increased media thickness-to-lumen diameter ratio, increased media volume, and increased numbers of smooth muscle cells per segment length and furthermore, they contracted more strongly than arteries from the neck (500 ± 49 vs. 318 ± 43 mmHg; n = 6 legs and neck, respectively). Finally, the transient increase in interstitial fluid pressure following injection of saline was 5.5 ± 1.7 times larger (n = 8) in the leg than in the neck. We conclude that 1) tissue compliance in the legs is low; 2) large arteries of the legs function as resistance arteries; and 3) structural adaptation of small muscle arteries allows them to develop an extraordinary tension. All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure.

  7. Model of distribution of dose for intravascular brachytherapy; Modelo de distribucion de dosis para braquiterapia intravascular

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, Rosana; Signoretta, Catalina [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Dosimetria de Radioaciones Ionizantes; Martin, Gabriela; Rivera, Elena; Bergoc, Rosa [Univeridad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica. Lab. de Radioisotopos; Guzman, Luis [Instituto Cardiovascular de Buenos Aires (Argentina)

    2001-07-01

    In this work we present the radiation dose distributions for a theoretical model with Monte Carlo simulation, which was based on an experimental model developed for the study of the prevention of restenosis post-angioplasty employing intravascular brachytherapy. In the experimental model, the atherosclerotic plaques were induced in femoral arteries of male New Zealand rabbits through surgical intervention and later administration of cholesterol enriched diet. For the intravascular irradiation we employed a {sup 32} P source contained within the balloon used for the angioplasty. The radiation dose distributions were calculated using the Monte Carlo code MCNP4B according to a segment of a simulated artery. We studied the radiation dose distribution in the axial and radial directions for different thickness of the atherosclerotic plaques. The results will be correlated with the biologic effects observed by means of histological analysis of the irradiated arteries. (author)

  8. Ultrasound changes in the relationship between the urethra and bladder neck caused by prolapse repair: feasibility and reliability of measurements.

    Science.gov (United States)

    Duckett, J; Lautmann, K

    2012-10-01

    The objective of this study was to assess whether intraoperative transperineal ultrasound can be used to assess changes in the relationship between the urethra and bladder caused by a prolapse repair operation. The reliability of the measurements was also assessed. A total of 25 women having an anterior colporrhaphy operation had pre- and post-repair imaging using a standard bladder volume. There was a statistically significant change (p ≤ 0.04) in the posterior urethrovesical angle (PUA) from 115° (SD 37) before surgery, to 135° (SD 30) after surgery. There was no significant change (p = 0.93) in the anterior urethrovesical angle before 73° (SD 14) after surgery 73° (SD 14). Interclass correlation coefficients showed good reproducibility for all measurements. Ultrasound can be used to measure changes in the relationship of the urethra and bladder produced by anterior colporrhaphy. Clinically, the effect of these changes is to reduce the angulation of the urethra in relation to the bladder.

  9. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. AISI/DOE Advanced Process Control Program Vol. 4 of 6: ON-LINE, NON-DESTRUCTIVE MECHANICAL PROPERTY MEASUREMENT USING LASER-ULTRASOUND

    Energy Technology Data Exchange (ETDEWEB)

    Andre' Moreau; Martin Lord; Daniel Levesqure; Marc Dubois; Jean Bussiere; Jean-Pierre Monchalin; Christian Padioleau; Guy Lamouche; Teodor Veres; Martin Viens; Harold Hebert; Pierre Basseras; Cheng-Kuei Jen

    2001-03-31

    The goal of this project was to demonstrate the feasibility to measure the mechanical properties, such as yield strength, tensile strength, elongation, strain hardening exponent and plastic strain ratio parameters, of low carbon steel sheets on the production line using laser ultrasound. The ultrasound generated by the developed apparatus travels mostly back and forth in the thickness of the steel sheet. By measuring the time delay between two echoes, and the relative amplitude of these two echoes, one can measure ultrasound velocity and attenuation. These are governed by the microstructure: grain size, crystallographic texture, dislocations, etc. Thus, by recording the time behavior of the ultrasonic signal, one can extract microstructural information. These microstructural information together with the modified Hall-Petch equation allow measurement of the mechanical properties. Through laboratory investigations with a laboratory laser ultrasound system, followed by the installation of a prototype system at LTV Steel Company's No.1 Inspection Line in Cleveland, all target mechanical properties of ultra low carbon (ULC), low carbon (LC) and high strength low alloy (HSLA) steel sample lots were measured meeting or nearly meeting all the target accuracies. Thus, the project realized its goal to demonstrate that the mechanical properties of low carbon steel sheets can be measured on-line using laser ultrasound

  11. Ultrasound colour Doppler measurements in a single joint as measure of disease activity in patients with rheumatoid arthritis--assessment of concurrent validity

    DEFF Research Database (Denmark)

    Ellegaard, K; Torp-Pedersen, S; Terslev, L

    2009-01-01

    correlations were found. CONCLUSION: A standardized ultrasound examination of a single affected wrist joint in patients with RA may be used as a measure of disease activity. More studies are needed to identify the number of joints needed to examine by CDU to obtain the best validity of Doppler measurements...... investigated if the amount of CDU activity in a single joint can be used to quantify disease activity in RA. METHODS: A total of 109 patients with RA and affection of the wrist joint underwent a standardized CDU examination assessing three positions in their most affected wrist at start up in biological...

  12. Relationships among dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA), and ultrasound measurements of body composition of swine

    Science.gov (United States)

    In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...

  13. Non-atherosclerotic spontaneous coronary artery dissection revascularized by intravascular ultrasonography-guided fenestration with cutting balloon angioplasty.

    Science.gov (United States)

    Ito, Tsuyoshi; Shintani, Yasuhiro; Ichihashi, Taku; Fujita, Hiroshi; Ohte, Nobuyuki

    2017-07-01

    A 46-year-old woman was referred to our hospital due to chest pain. Twelve-lead electrocardiogram revealed ST-segment elevation suggesting acute myocardial infarction. Emergent coronary angiography showed diffuse narrowing and occlusion in the middle to distal left anterior descending artery (LAD). To investigate the cause of occlusion, an intravascular ultrasound (IVUS) examination was performed and we diagnosed spontaneous coronary artery dissection (SCAD) as the cause of occlusion. After a cutting balloon was dilated at the distal LAD, coronary flow recovered. IVUS-guided angioplasty with cutting balloon could be a choice of treatment in SCAD patients who need revascularization.

  14. Intravascular catheter-related bloodstream infection.

    Science.gov (United States)

    Shah, Harshal; Bosch, Wendelyn; Thompson, Kristine M; Hellinger, Walter C

    2013-07-01

    Intravascular catheters required for the care of many hospitalized patients can give rise to bloodstream infection, a complication of care that has occurred most frequently in intensive care unit (ICU) settings. Elucidation of the pathogenesis of catheter-related bloodstream infections (CRBSIs) has guided development of effective diagnostic, management, and prevention strategies. When CRBSIs occur in the ICU, physicians must be prepared to recognize and treat them. Prevention of these infections requires careful attention to optimal catheter selection, insertion and maintenance, and to removal of catheters when they are no longer needed. This review provides a succinct summary of the epidemiology, pathogenesis, and microbiology of CRBSIs and a review of current guidance for the diagnosis, management, and prevention of these infections.

  15. Death following intravascular administration of contrast media

    International Nuclear Information System (INIS)

    Shehadi, W.H.

    1985-01-01

    Adverse reactions to intravascularly administered contrast media preceding death and the autopsy findings in 44 patients are presented. There is a wide scatter of the age distribution of fatal reactions. The highest incidence is in the 50-70 year age group. Similar observations were obtained from the 405 deaths due to contrast media reported to the Food and Drug Administration of the United States. In the same age group the number of reactions is highest, likewise the autopsy findings. The predominant autopsy findings are pulmonary edema, congestion and hemorrhage; arteriosclerosis, both general and coronary. In the younger age group the autopsy findings are limited mostly to the respiratory tract. Fatal reactions to contrast media occur often without warning and most deaths occur within 15 min to 6 hours. Reactions to contrast media occur without relation to sex or age. (orig.)

  16. Quinine-Induced Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Firas Abed

    2016-01-01

    Full Text Available Every drug comes with some side effect. It is the benefit/risk ratio that determines the medical use of the drug. Quinine, a known antimalarial drug, has been used for nocturnal leg cramps since the 1930s; it is associated with severe life-threatening hematological and cardiovascular side effects. Disseminated intravascular coagulation (DIC, albeit rare, is a known coagulopathy associated with Quinine. It is imperative to inquire about the Quinine intake in medication history in patients with coagulopathy, as most patients still consider it a harmless home remedy for nocturnal leg cramps. In this report, we present a case of coagulopathy in a middle-aged woman, who gave a history of taking Quinine for nocturnal leg cramps, as her home remedy. Early identification of the offending agent led to the diagnosis, prompt discontinuation of the medication, and complete recovery and prevented the future possibility of recurrence.

  17. Chronic Disseminated Intravascular Coagulation: A Case Report

    Directory of Open Access Journals (Sweden)

    Md Abul Kalam Azad

    2009-11-01

    Full Text Available In health there is a balance between the coagulation and anti-coagulation systems, but in disseminated intravascular coagulation (DIC the coagulation mechanism is activated inappropriately and in a diffuse way. This may lead to thrombosis, but more often haemorrhage occurs when the clotting factors are exhausted. DIC may present as acute, subacute, and rarely chronic form. Here we present a case of chronic DIC following pelvic inflammatory disease (PID as a consequence of repeated menstruation regulation (MR. We treated her with fresh frozen plasma, fresh blood, doxycycline with significant clinical improvement.DOI: 10.3329/bsmmuj.v1i1.3696 BSMMU J 2008; 1(1: 33-34

  18. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  19. Relationship between two-dimensional ultrasound measurement of placental thickness and estimated fetal weight

    Directory of Open Access Journals (Sweden)

    Ademola A Adeyekun

    2015-01-01

    Full Text Available Background/Aim: The placenta plays a major role in fetal well-being, and fetal weight is very important to neonatal survival. There probably exists a relationship between placental dimension and fetal size. Data on ultrasound assessed placenta thickness and fetal weight are scanty in the Nigerian literature. This study aimed to establish a relationship between ultrasound estimated placental thickness and fetal weight. Materials and Methods: Four hundred and twenty apparently healthy pregnant women at gestational age 15-40 weeks were sonographically examined, with a 3.5 MHz curvilinear transducer of a Sonoace X6 machine (Medison Co., Korea. Placenta thickness, in millimeters, and fetal weight, in grams, was estimated for each subject. Correlation between the two parameters was assessed. P ≤ 0.05 were considered to be significant. Results: Mean placental thickness (PT ranged from 22.6 ± 2.5 mm at 15 weeks to 40.9 ± 7.2 mm at 30 weeks, while estimated fetal weight (EFW ranged from 147.0 ± 16.5 g at 15 weeks to 3.304.8 ± 284.6 g at 40 weeks. The mean values of placenta thickness and EFW throughout gestation were 35.5 ± 7.0 mm and 1555.0 ± 1004 g, respectively. There was significant correlation between placenta thickness and EFW r = 0.668; P = 0.000. Conclusion: The study established a fairly linear relationship between placental thickness and EFW. A normogram of ultrasound estimated placenta thickness and fetal weight is derived.

  20. Matlab-based interface for the simultaneous acquisition of force measures and Doppler ultrasound muscular images.

    Science.gov (United States)

    Ferrer-Buedo, José; Martínez-Sober, Marcelino; Alakhdar-Mohmara, Yasser; Soria-Olivas, Emilio; Benítez-Martínez, Josep C; Martínez-Martínez, José M

    2013-04-01

    This paper tackles the design of a graphical user interface (GUI) based on Matlab (MathWorks Inc., MA), a worldwide standard in the processing of biosignals, which allows the acquisition of muscular force signals and images from a ultrasound scanner simultaneously. Thus, it is possible to unify two key magnitudes for analyzing the evolution of muscular injuries: the force exerted by the muscle and section/length of the muscle when such force is exerted. This paper describes the modules developed to finally show its applicability with a case study to analyze the functioning capacity of the shoulder rotator cuff. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Ultrasound elastography as an objective diagnostic measurement tool for lymphoedema of the treated breast in breast cancer patients following breast conserving surgery and radiotherapy

    International Nuclear Information System (INIS)

    Adriaenssens, Nele; Belsack, Dries; Buyl, Ronald; Ruggiero, Leonardo; Breucq, Catherine; De Mey, Johan; Lievens, Pierre; Lamote, Jan

    2012-01-01

    Lymphoedema of the operated and irradiated breast is a common complication following early breast cancer treatment. There is no consensus on objective diagnostic criteria and standard measurement tools. This study investigates the use of ultrasound elastography as an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema. The elasticity ratio of the subcutis, measured with ultrasound elastography, was compared with high-frequency ultrasound parameters and subjective symptoms in twenty patients, bilaterally, prior to and following breast conserving surgery and breast irradiation. Elasticity ratio of the subcutis of the operated breast following radiation therapy increased in 88.9% of patients, was significantly higher than prior to surgery, unlike the non operated breast and significantly higher than the non operated breast, unlike preoperative results. These results were significantly correlated with visibility of the echogenic line, measured with high-frequency ultrasound. Big preoperative bra cup size was a significant risk factor for the development of breast oedema. Ultrasound elastography is an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema, in combination with other objective diagnostic criteria. Further research with longer follow-up and more patients is necessary to confirm our findings

  2. Fetal biacromial diameter as a new ultrasound measure for prediction of macrosomia in term pregnancy: a prospective observational study.

    Science.gov (United States)

    Youssef, Alaa Eldin A; Amin, Ahmed F; Khalaf, Mohamed; Khalaf, Marwa S; Ali, Mohammed K; Abbas, Ahmed M

    2018-02-25

    The current study aims to evaluate a simple method for sonographic measurement of the fetal biacromial diameter for prediction of fetal macrosomia in term pregnancy. The current study was a single center prospective observational study conducted in a tertiary University Hospital from January 2015 to May 2017. We included all consecutive term (37-42 weeks) pregnant women presented to the labor ward for delivery. Ultrasound parameters were measured as biparietal diameter, head circumference, transverse thoracic diameter, mid arm diameter, abdominal circumference, femur length, estimated fetal weight and amniotic fluid index. The proposed ultrasound formula "Youssef's formula" to measure the fetal biacromial diameter is: [Transverse thoracic diameter + 2 × midarm diameter]. The accuracy of proposed formula was compared to the actual biacromial diameter of the newborn after delivery. The primary outcome of the study was accuracy of sonographic measurement of fetal biacromial diameter in prediction of fetal macrosomia in terms of sensitivity and specificity Results: The study included 600 participants; 49 (8.2%) of them delivered a macrosomic neonates and 551 (91.8%) delivered average weight neonates. There was no statistical significant difference between the proposed fetal biacromial diameter measured by ultrasound and the actual neonatal biacromial diameter measured after birth (p = 0.192). The area under the curve (AUC) for prediction of macrosomia at birth based on the fetal biacromial diameter and the abdominal circumference was 0.987 and 0.989, respectively on receiver operating characteristic (ROC) curve analysis. Using the biacromial diameter cutoff of 15.4 cm has a PPV for prediction of macrosomia (88.4%) and 96.4% sensitivity with overall accuracy of 97%. Similarly, with the abdominal circumference (AC) cutoff of 35.5 cm, the PPV for prediction of macrosomia (87.7%) and 96.4% sensitivity with overall accuracy of 96.83%. No statistical significant

  3. Reproducibility and interoperator reliability of obtaining images and measurements of the cervix and uterus with brachytherapy treatment applicators in situ using transabdominal ultrasound.

    Science.gov (United States)

    van Dyk, Sylvia; Garth, Margaret; Oates, Amanda; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash

    2016-01-01

    To validate interoperator reliability of brachytherapy radiation therapists (RTs) in obtaining an ultrasound image and measuring the cervix and uterine dimensions using transabdominal ultrasound. Patients who underwent MRI with applicators in situ after the first insertion were included in the study. Imaging was performed by three RTs (RT1, RT2, and RT3) with varying degrees of ultrasound experience. All RTs were required to obtain a longitudinal planning image depicting the applicator in the uterine canal and measure the cervix and uterus. The MRI scan, taken 1 hour after the ultrasound, was used as the reference standard against which all measurements were compared. Measurements were analyzed with intraclass correlation coefficient and Bland-Altman plots. All RTs were able to obtain a suitable longitudinal image for each patient in the study. Mean differences (SD) between MRI and ultrasound measurements obtained by RTs ranged from 3.5 (3.6) to 4.4 (4.23) mm and 0 (3.0) to 0.9 (2.5) mm on the anterior and posterior surface of the cervix, respectively. Intraclass correlation coefficient for absolute agreement between MRI and RTs was >0.9 for all posterior measurement points in the cervix and ranged from 0.41 to 0.92 on the anterior surface. Measurements were not statistically different between RTs at any measurement point. RTs with variable training attained high levels of interoperator reliability when using transabdominal ultrasound to obtain images and measurements of the uterus and cervix with brachytherapy applicators in situ. Access to training and use of a well-defined protocol assist in achieving these high levels of reliability. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Measuring body layer vibration of vocal folds by high-frame-rate ultrasound synchronized with a modified electroglottograph.

    Science.gov (United States)

    Tang, Shanshan; Zhang, Yuanyuan; Qin, Xulei; Wang, Supin; Wan, Mingxi

    2013-07-01

    The body-cover concept suggests that the vibration of body layer is an indispensable component of vocal fold vibration. To quantify this vibration, a synchronized system composed of a high-frame-rate ultrasound and a modified electroglottograph (EGG) was employed in this paper to simultaneously image the body layer vibration and record the vocal fold vibration phase information during natural phonations. After data acquisition, the displacements of in vivo body layer vibrations were measured from the ultrasonic radio frequency data, and the temporal reconstruction method was used to enhance the measurement accuracy. Results showed that the modified EGG, the waveform and characteristic points of which were identical to the conventional EGG, resolved the position conflict between the ultrasound transducer and EGG electrodes. The location and range of the vibrating body layer in the estimated displacement image were more clear and discernible than in the ultrasonic B-mode image. Quantitative analysis for vibration features of the body layer demonstrated that the body layer moved as a unit in the superior-inferior direction during the phonation of normal chest registers.

  5. Development of a body condition scoring index for female African elephants validated by ultrasound measurements of subcutaneous fat.

    Science.gov (United States)

    Morfeld, Kari A; Lehnhardt, John; Alligood, Christina; Bolling, Jeff; Brown, Janine L

    2014-01-01

    Obesity-related health and reproductive problems may be contributing to non-sustainability of zoo African elephant (Loxodonta africana) populations. However, a major constraint in screening for obesity in elephants is lack of a practical method to accurately assess body fat. Body condition scoring (BCS) is the assessment of subcutaneous fat stores based on visual evaluation and provides an immediate appraisal of the degree of obesity of an individual. The objective of this study was to develop a visual BCS index for female African elephants and validate it using ultrasound measures of subcutaneous fat. To develop the index, standardized photographs were collected from zoo (n = 50) and free-ranging (n = 57) female African elephants for identifying key body regions and skeletal features, which were then used to visually determine body fat deposition patterns. This information was used to develop a visual BCS method consisting of a list of body regions and the physical criteria for assigning an overall score on a 5-point scale, with 1 representing the lowest and 5 representing the highest levels of body fat. Results showed that as BCS increased, ultrasound measures of subcutaneous fat thickness also increased (Pelephants, the median BCS in the free-ranging individuals (BCS = 3, range 1-5) was lower (Pelephants. This tool can be used to examine which factors impact body condition in zoo and free-ranging elephants, providing valuable information on how it affects health and reproductive potential of individual elephants.

  6. Ultrasound guided pO2 measurement of breast cancer reoxygenation after neoadjuvant chemotherapy and hyperthermia treatment.

    Science.gov (United States)

    Vujaskovic, Z; Rosen, E L; Blackwell, K L; Jones, E L; Brizel, D M; Prosnitz, L R; Samulski, T V; Dewhirst, M W

    2003-01-01

    The objective of this study was to determine whether neoadjuvant chemotherapy in combination with hyperthermia (HT) would improve oxygenation in locally advanced breast tumours. The study describes a new optimized ultrasound guided technique of pO2 measurement using Eppendorf polarographic oxygen probes in 18 stage IIB-III breast cancer patients. Prior to treatment, tumour hypoxia (median pO2pO2=3.2 mmHg). Seven patients had well oxygenated tumours (median pO2 of 48.3 mmHg). Eight patients with hypoxic tumours prior to treatment had a significant improvement (p=0.0008) in tumour pO2 after treatment (pO2 increased to 19.2 mmHg). In three patients, tumours remained hypoxic (average median pO2=4.5 mmHg). The advantages of the ultrasound guided pO2 probe are in the accuracy of the Eppendorf electrode placement in tumour tissue, the ability to monitor electrode movement through the tumour tissue during the measurement and the ability to avoid electrode placement near or in large blood vessels by using colour Doppler imaging. The results of this preliminary study suggest that the combination of neoadjuvant chemotherapy and hyperthermia improves oxygenation in locally advanced breast tumours that are initially hypoxic.

  7. Effect of oral contraceptive with and without associated estriol on ultrasound measurements of breast fibroadenoma: randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Rodrigo Augusto Fernandes Estevão

    Full Text Available CONTEXT AND OBJECTIVE: Fibroadenomas are the most common benign tumors of the female breast. The aim of this study was to evaluate the proliferative activity of breast fibroadenoma as shown by ultrasound measurements, following administration of oral contraceptives with and without associated estriol. DESIGN AND SETTING: This was a randomized, double-blind, placebo-controlled clinical trial carried out in the Mastology Sector, Department of Gynecology, Universidade Federal de São Paulo. METHODS: We studied 33 women with fibroadenomas. Ten were placed in group 1 and took an oral contraceptive consisting of levonorgestrel and ethinyl estradiol together with placebo material in the same capsule, for four consecutive cycles with a seven-day interval between them. The other 23 patients constituted group 2 and took the oral contraceptive as above together with estriol in the same capsule, in the same way as done by the group 1 patients. We took ultrasound measurements of their tumors (in three dimensions before and after the intake of medication. At the end of the study, all the patients had their tumors removed by surgery. RESULTS: We observed decreased fibroadenoma width among the users of oral contraceptives with placebo, and this decrease was statistically significant. In the other group, we did not observe any changes (in width, length or height. CONCLUSION: The results confirm that estriol may block the protective effect of oral contraceptives on fibroadenomas, since we observed decreased fibroadenoma width among the group 1 patients but not the group 2 patients.

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary bladder ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  11. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...... on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...

  12. Changes in recruitment of the abdominal muscles in people with low back pain: ultrasound measurement of muscle activity.

    Science.gov (United States)

    Ferreira, Paulo H; Ferreira, Manuela L; Hodges, Paul W

    2004-11-15

    Ultrasound and electromyographic (EMG) measures of trunk muscle activity were compared between low back pain (LBP) and control subjects in a cross-sectional study. To compare the recruitment of the abdominal muscles (measured as a change in thickness with ultrasound imaging) between people with and without low back pain and to compare these measurements with EMG recordings made with intramuscular electrodes. Although ultrasonography has been advocated as a noninvasive measure of abdominal muscle activity, it is not known whether it can provide a valid measure of changes in motor control of the abdominal muscles in LBP. Ten subjects with recurrent LBP and 10 matched controls were tested during isometric low load tasks with their limbs suspended. Changes in thickness from resting baseline values were obtained for transversus abdominis (TrA), obliquus internus (OI), and obliquus externus (OE) using ultrasonography. Fine wire EMG was measured concurrently. Study participants with LBP had a significantly smaller increase in TrA thickness with isometric leg tasks compared with controls. No difference was found between groups for OI or OE. Similar results were found for EMG. People with LBP had less TrA EMG activity with leg tasks, and there was no difference between groups for EMG activity for OI or OE. This study reinforces evidence for changes in automatic control of TrA in people with LBP. Furthermore, the data establish a new test of recruitment of the abdominal muscles in people with LBP. This test presents a feasible noninvasive test of automatic recruitment of the abdominal muscles.

  13. Use of B-mode ultrasound to examine preclinical markers of atherosclerosis: image quality may bias associations between adiposity and measures of vascular structure and function.

    Science.gov (United States)

    Magnussen, Costan G; Thomson, Russell; Juonala, Markus; Viikari, Jorma S A; Dwyer, Terence; Raitakari, Olli T; Venn, Alison

    2011-03-01

    The purpose of this study was to examine the association between adiposity measures, ultrasound image quality, and preclinical markers of atherosclerosis in young adults. B-mode ultrasound was used to obtain common carotid intima-media thickness and common carotid artery distensibility of 2265 and 1313 adults aged 24 to 39 years in two population-based studies: the Cardiovascular Risk in Young Finns and Childhood Determinants of Adult Health studies. Qualitative assessments of ultrasound image quality were obtained from each study (scored as 1, excellent; 2, average; and 3, poor) based on the ability to detect arterial interfaces and the amount of noise present in the image. Increased adiposity was associated with significantly increased odds (all P media thickness in Young Finns (regression coefficient = -0.029; P = .01) and higher intima-media thickness in Childhood Determinants of Adult Health (regression coefficient = 0.013; P = .03) and lower distensibility levels in both studies (Young Finns, β = -.494; P bias) in the association between adiposity measures and carotid intima-media thickness by image quality, but there was some evidence suggesting that the association between adiposity measures and carotid distensibility differed by image quality. Adiposity affects ultrasound image quality and has the potential to bias associations between adiposity and preclinical markers of atherosclerosis. Studies examining adiposity and ultrasound-derived measures of atherosclerosis should consider taking steps during the design and analysis phase to adequately account for variations in image quality to avoid any potential bias.

  14. Intravascular photoacoustic detection of vulnerable plaque based on constituent selected imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jian; Xing Da, E-mail: xingda@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China)

    2011-01-01

    Atherosclerosis, a disease of the large arteries, is the primary cause of heart disease and stroke. Over decades, atherosclerosis is characterized by thickening of the walls of the arteries, only advanced atherosclerotic disease could be observed. Photoacoustic imaging is a hybrid imaging technique that combines the advantages of high spatial resolution of ultrasound with contrast of optical absorption. In this paper, we present an intravascular photoacoustic (IVPA) imaging system to characterize vulnerable plaques by using the optical absorption contrast between different constituents. Epidemiological studies have revealed several important plaque constituents associated with early atherosclerosis, such as macrophage, cholesterol, lipid, calcification, and so on. We chose a section of lipid rich atherosclerosis artery and a section of normal artery as the phantom. Two IVPA images of them are given to show the difference between sick and normal. As a new method of detecting vulnerable plaque, IVPA constituents imaging will provide more details for diagnosis that offer an enticing prospect in early detecting of atherosclerosis.

  15. Prediction of postpercutaneous coronary intervention myocardial infarction: insights from intravascular imaging, coronary flow, and biomarker evaluation.

    Science.gov (United States)

    Hoole, Stephen P; Hernández-Sánchez, Jules; Brown, Adam J; Giblett, Joel P; Bennett, Martin R; West, Nick E J

    2018-05-01

    Percutaneous coronary intervention-induced myocardial infarction (PMI) has prognostic significance. Identifying patients at high risk for PMI is desirable as it may alter strategy and facilitate early preventative therapy. We therefore sought to establish whether preprocedural demographic, interventional (plaque characteristics and coronary microcirculatory function), and inflammatory, endothelial damage, and platelet-derived biomarker data could predict the risk of PMI. We performed target vessel pressure wire to assess fractional flow reserve, index of microcirculatory resistance (IMR) and coronary flow reserve, plaque characterization by virtual histology intravascular ultrasound, and assayed peripheral biomarkers before uncomplicated PCI in 88 patients. We then analyzed post-PCI cardiac troponin level to adjudicate PMI based on the third universal definition of myocardial infarction. Overall incidence of PMI was 27%. Women [10/15 (66%) vs. 14/73 (19%), PPMI. Preprocedural coronary flow reserve was lower in individuals with a subsequent PMI (1.8±1.2 vs. 2.1±1.3. P=0.03), and patients with higher pre-PCI IMR were more likely to sustain PMI [IMR>22: 10/23 (44%) vs. ≤22: 14/65 (22%), P=0.04], although neither was predictive after multivariate analysis. Plaque characterization by virtual histology intravascular ultrasound did not discriminate those at risk of PMI. However, peripheral venous interleukin (IL)-18 and IL-8 levels were independently negatively and positively associated with PMI, respectively. Women and those with low BMI, particularly when associated with high IL-8 and low IL-18 levels, appear to be at increased risk of PMI.

  16. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.

    NARCIS (Netherlands)

    Vrancken, S.L.A.G.; Boode, W.P. de; Hopman, J.C.W.; Singh, S.; Liem, K.D.; Heyst, A.F.J. van

    2012-01-01

    BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a

  17. Reproducibility of first- and second-trimester uterine artery pulsatility index measured by transvaginal and transabdominal ultrasound.

    Science.gov (United States)

    Ferreira, A E G M T; Mauad Filho, F; Abreu, P S G; Mauad, F M; Araujo Júnior, E; Martins, W P

    2015-11-01

    To examine and compare the reproducibility of measurement of first- and second-trimester uterine artery pulsatility index (UtA-PI) using transabdominal (TAS) and transvaginal (TVS) ultrasound. This was an observational study including women ≥ 18 years of age, with a singleton pregnancy, in the first trimester (between 11 + 0 and 13 + 6 weeks' gestation) or second trimester (between 20 and 26 weeks' gestation). UtA-PI and angle of insonation were assessed by two observers (one with 15 and the other with 3 years of experience) using both TAS and TVS. The more experienced observer performed two scans alternated by the other observer. The acquisitions were completely independent and the observers were blinded to each other and to their own measurements. Reproducibility of the measurements by TVS and TAS was assessed using the concordance correlation coefficients (CCCs), intraclass correlation coefficients (ICCs) and limits of agreement (LoA). We analyzed data from 97 women in the first trimester and 96 in the second trimester. The mean ± SD UtA-PI was significantly higher when measured using TVS, compared with TAS, in both the first (1.60 ± 0.49 vs 1.52 ± 0.63, respectively; P = 0.03) and second (1.07 ± 0.33 vs 0.96 ± 0.32, respectively; P UtA-PI, assessment by TVS provides higher values and better insonation angle compared with TAS. The reproducibility of the ultrasound methods in both first and second trimesters of pregnancy was comparable and should not be considered as good. Future studies examining technical improvements with the aim of increasing the reproducibility of this technique should be encouraged. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  18. An ultrasound-based liquid pressure measurement method in small diameter pipelines considering the installation and temperature.

    Science.gov (United States)

    Li, Xue; Song, Zhengxiang

    2015-04-09

    Liquid pressure is a key parameter for detecting and judging faults in hydraulic mechanisms, but traditional measurement methods have many deficiencies. An effective non-intrusive method using an ultrasound-based technique to measure liquid pressure in small diameter (less than 15 mm) pipelines is presented in this paper. The proposed method is based on the principle that the transmission speed of an ultrasonic wave in a Kneser liquid correlates with liquid pressure. Liquid pressure was calculated using the variation of ultrasonic propagation time in a liquid under different pressures: 0 Pa and X Pa. In this research the time difference was obtained by an electrical processing approach and was accurately measured to the nanosecond level through a high-resolution time measurement module. Because installation differences and liquid temperatures could influence the measurement accuracy, a special type of circuit called automatic gain control (AGC) circuit and a new back propagation network (BPN) model accounting for liquid temperature were employed to improve the measurement results. The corresponding pressure values were finally obtained by utilizing the relationship between time difference, transient temperature and liquid pressure. An experimental pressure measurement platform was built and the experimental results confirm that the proposed method has good measurement accuracy.

  19. Two-photon photoacoustics ultrasound measurement by a loss modulation technique

    Science.gov (United States)

    Lai, Yu-Hung; Chang, Chieh-Feng; Cheng, Yu-Hsiang; Sun, Chi-Kuang

    2013-03-01

    In this work, we investigated the principle of the two-photon absorption (TPA) detection with a loss modulation technique, and first demonstrated the existence of two-photon photoacoustics ultrasound excited by a femtosecond high repetition rate laser. By using the AO modulation with different modulation frequencies, we successfully create the beating of the light signal when the two arms of the beams are both spatial and temporal overlapping. The pulse train of the femtosecond laser causes the narrow band excitation, providing the frequency selectivity and sensitivity. Moreover, the pulse energy is no more than 15nJ/pulse, which is at least 3 orders of magnitude smaller than that of the nanosecond laser, and therefore prevents the thermal damage of the sample. With the help of lock-in detection and a low noise amplifier, we can separate the signal of two-photon absorption from one-photon absorption. We used an ultrasonic transducer to detect the response of the sample, and verified the existence of the two-photon photoacoustics ultrasound generating by the femtosecond laser. Several contrast agents, such as the black carbon solution, the fluorescence dye and the nano-particles, were used in the experiment. In the end, we demonstrated the application, two photo-acoustic imaging, which provides the high spatial resolution (<10μm) and large penetration depth (~1mm), to the simulated biological tissue. This is a milestone to develop the two-photon photoacoustics microscopy, which, in principle, has the great potential to achieve the in vitro and in vivo high resolution deep tissue imaging.

  20. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  1. A comparison of ultrasound measurements to assess carotid atherosclerosis development in subjects with and without type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Zinman Bernard

    2005-06-01

    Full Text Available Abstract Background Subjects with type 2 diabetes are at an increased risk of vascular complications. The use of carotid ultrasound remains an attractive, non-invasive method to monitor atherosclerotic disease progression and/or response to treatment in patients with type 2 diabetes, with intima-media thickness routinely used as the gold standard to detect pathology. However, alternative measurements, such as plaque area or volume, may represent a potentially more powerful approach. Thus, the objective of this study was to compare the traditional intima-media thickness measurement against the novel total plaque volume measurement in analyzing carotid atherosclerosis development in individuals with type 2 diabetes. Methods The case-control study included 49 Oji-Cree adults with diabetes or impaired glucose tolerance, aged 21–69, and 49 sex- and age-matched normoglycemic subjects. At baseline, metabolic variables were measured, including body mass index, waist circumference, total cholesterol:high density lipoprotein ratio, plasma triglycerides, plasma glucose, and serum insulin. Carotid ultrasound measurements, 7 years later, assessed carotid arterial intima-media thickness and total plaque volume. Results At baseline, the two groups were well matched for smoking habits, hypertension, body mass index, and waist circumference. Differences were noted in baseline measurements of total cholesterol:high density lipoprotein (P = 0.0006, plasma triglycerides (P P P = 0.037, but not intima-media thickness measurements, were higher in subjects with diabetes/impaired glucose tolerance compared to the normoglycemic controls. Correlation between intima-media thickness and total plaque volume was moderate. Based on our study findings, to achieve power levels >0.70 when comparing intima-media thickness measurements for diabetics versus non-diabetics, thousands of study subjects are required. For comparing total plaque volume measurements, only hundreds of

  2. Intravascular Large B-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Maria S. Khan MD, FACP

    2014-03-01

    Full Text Available Case Presentation . A 69-year-old Hispanic male, with a past history of diabetes and coronary disease, was admitted for fever, diarrhea, and confusion of 4 weeks duration. Physical examination showed a disoriented patient with multiple ecchymoses, possible ascites, and bilateral scrotal swelling. Hemoglobin was 6.7, prothrombin time (PT 21.4 seconds with international normalized ratio 2.1, partial thromboplastin time (PTT 55.6 seconds, fibrin split 10 µg/L, and lactate dehydrogenase (LDH 1231 IU/L. Except for a positive DNA test for Epstein–Barr virus (EBV infection, extensive diagnostic workup for infections, malignancy, or a neurological cause was negative. Mixing studies revealed a nonspecific inhibitor of PT and PTT but Factor VIII levels were normal. The patient was empirically treated with antibiotics but developed hypotension and died on day 27 of admission. At autopsy, patient was found to have intravascular diffuse large B-cell lymphoma involving skin, testes, lung, and muscles. The malignant cells were positive for CD20, CD791, Mum-1, and Pax-5 and negative for CD3, CD5, CD10, CD30, and Bcl-6. The malignant cells were 100% positive for Ki-67. Discussion . Intravascular large cell B-cell lymphoma (IVLBCL is rare form of diffuse large B-cell lymphoma and tends to proliferate within small blood vessels, particularly capillaries and postcapillary venules. The cause of its affinity for vascular bed remains unknown. In many reports, IVLBCL was associated with HIV, HHV8, and EBV infections. The fact that our case showed evidence of EBV infection lends support to the association of this diagnosis to viral illness. The available literature on this subject is scant, and in many cases, the diagnosis was made only at autopsy. The typical presentation of this disorder is with B symptoms, progressive neurologic deficits, and skin findings. Bone marrow, spleen, and liver are involved in a minority of patients. Nearly all patients have elevated LDH

  3. THROMBOPHILIA AND INTENSITY OF THE INTRAVASCULAR MICROCOAGULATION IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE, ATHEROTHROMBOSIS

    Directory of Open Access Journals (Sweden)

    E. A. Shelest

    2015-09-01

    Full Text Available Aim. To study the intensity of the intravascular microcoagulation in patients with atherothrombosis (AT, chronic obstructive pulmonary disease (COPD and thrombophilia.Material and methods. 115 patients were enrolled into the study: 37 patients with COPD (22 with thrombophilia and 15 without thrombophilia; 37 patients with AT (23 with thrombophilia and 14 without thrombophilia; 41 patients with COPD+AT (24 with thrombophilia and 17 without thrombophilia. In the control group 53 healthy people (39 with thrombophilia and 14 without thrombophilia were included. Median age was 62 (56.5, 69 years. The intensity of intravascular microcoagulation was measured: platelet factor 4 (PF4 by ELISA, D-dimer by ELISA, XIIa-dependent fibrinolysis (time. Polymerase chain reaction was used for detection of such trombophilia parameters as Leiden mutation, prothrombin gene mutation 20210A, mutation in the gene of methylenetetrahydrofolate reductase (MTHFR and plasminogen activator inhibitor-1 (PAI-1.Results. The level of PF4 and D-dimer was significantly higher while fibrinolytic activity was lower in COPD (103.5 ME/ml, 70 ng/ml, 650 s, respectively, AT (127.1 ME/ml, 96,9 ng/ml, 850 s, respectively and COPD+AT (136.5 ME/ml, 106.5 ng/ml, 1148 s, respectively groups as compared with the control group (p<0.05. When analyzing the level of intravascular coagulation parameters in patients with thrombophilia and without it, levels of PF4, D-dimer and XIIa-dependent fibrinolysis (time were significantly higher in thrombophilia subgroups among all patients (p<0.05. In patients with thrombophilia levels of these parameters were significantly higher in those with two or more thrombophilia gene polymorphisms than with one (p<0.01.Conclusion. The intensity of intravascular microcoagulation increases in patients with thrombophilia, atherothrombosis and COPD.

  4. The relationship between intravascular volume expansion and natriuresis in developing puppies.

    Science.gov (United States)

    Aladjem, M; Spitzer, A; Goldsmith, D I

    1982-10-01

    The role played by the relative degree of expansion of the intravascular and extravascular compartments in limiting the natriuretic response of fluid-loaded developing animals was determined in 1-, 2-, 3- and 6-wk-old puppies. Volume expansion was induced by infusing either isotonic saline, 10% body weight or isoncotic albumin in saline 5% body weight, and measurements of glomerular filtration rate, sodium excretion, fractional excretion of sodium, and plasma volume were made. Each expansion procedure resulted in an increase in the absolute excretion of sodium at all ages (P less than 0.001). The greatest natriuretic effect was observed in the 3-wk-old puppies, the average of the two solutions being 19, 30, 70, and 28 muEq/min/kg in the 1, 2, 3, and 6-wk-old animals, respectively. The difference in natriuresis among the age groups was due predominantly to differences in the magnitude of the increase in fractional excretion of sodium. At all ages, a greater absolute excretion of sodium was encountered during volume expansion with saline than observed with albumin (P less than 0.05). The intravascular volume increased by a similar % at all ages (P greater than 0.1), and saline and albumin yielded equivalent degrees of intravascular expansion (approximately 50%). The results demonstrate that age-related changes in natriuretic response to volume expansion cannot be attributed to differences in either the degree of expansion or the distribution of the load. In addition, the observations indicate that the mechanism underlying the difference between the response to isotonic saline and isoncotic albumin in saline is already operative at birth, and that it is independent of nephron heterogeneity since the proportion of superficial nephrons must have changed during the period of nephrogenesis. The collecting duct, which is sensitive to both isotonic saline and isoncotic albumin, is likely to be responsible for the parallel development of the renal response to these two

  5. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  6. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  7. Effects of Hot Packs on Small-Intestinal Motility Measured by Doppler Ultrasound and Subjective Feelings in Normal Adults.

    Science.gov (United States)

    Makino, Yusuke; Choe, Myoung-Ae

    Constipation is a common problem in patients and the general population. Hot packs can relieve constipation, but the effect on small-intestinal motility remains unknown. We aimed to determine the effect of hot packs on small-intestinal motility and subjective feelings associated with bowel activity after removing the hot packs. Thirty-four normal adults were assigned to either an experimental group (n = 18) or a control group (n = 16). Hot and normal packs were applied for 10 minutes to the lumbar regions of the experimental and control groups, respectively. Small-intestinal motility was measured by Doppler ultrasound before, during, and after pack application. Subjective feelings were also evaluated after removing the packs. The number of small-intestinal peristalses and subjective feelings of 20 participants showing anechoic areas in the small-intestinal lumen were analyzed.

  8. 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2013-01-01

    -lobe levels are higher for the row-column addressed array. The cystic resolution sampled at a relative intensity difference of 20 dB shows a cyst size of 5.00mm for the row-column addressed array and 2.39mm for the fully sampled array. A simulation study is carried out which compares how the imaging quality...... is 510% larger than when row-column addressing the array. The cyst radius needed to achieve -20 dB intensity in the cyst is 396% larger for the fully addressed array compared to the row-column addressed array. The measurements were made using the experimental ultrasound scanner SARUS and a 32x32 element...

  9. [Intravascular lymphomatosis. A report of three cases].

    Science.gov (United States)

    Menéndez Calderón, M J; Seguí Riesco, M E; Argüelles, M; Nuño Mateo, J

    2005-01-01

    Intravascular lymphomatosis (IVL) is a rare malignancy characterized by a proliferation of atypical lymphoid cells occluding small blood vessels (venules, capillaries and small arteries). The symptoms are caused by embolisms due to massive proliferation. Nervous system and skin are the most common sites of involvement but all organs may be involved, although it is typified by the absence of malignant cells in lymphoid tissues. We describe three cases of IVL: first patient was a 57 years old man with rapidly progressive dementia and neurological involvements and second case of a 69 years old man hospitalised with predominant symptoms in the lung (cough, dyspnea and fever), and a woman presenting as fever of unknown origin (FUO) with systemic inflammatory response syndrome. In all cases that we reported have been diagnosed post-mortem because of rapid progression of a multisystem disease and the absence of pathognomonic clinical manifestations. Diagnosis can be made using biopsy of one of the involved organs. In conclusion, we propose that IVL should be included in the differential diagnosis of acute confusional state, dementia or other unexplained neurological manifestations, fever of unknown origin, vasculitis, occult neoplasia or infections with signs of a systemic disease and marked elevation of serum lactate dehydrogenase (LDH).

  10. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  11. Stress predicts the trajectory of wound healing in living kidney donors as measured by high-resolution ultrasound.

    Science.gov (United States)

    Maple, Hannah; Chilcot, Joseph; Lee, Vanessa; Simmonds, Shanique; Weinman, John; Mamode, Nizam

    2015-01-01

    Psychological stress has been shown to be an influential factor on the rate of wound healing; however these findings have been demonstrated predominantly on artificially created wounds. Due to the absence of major co-morbidities, living kidney donors are a unique group in which to study this relationship. This study investigated the effect of preoperative stress and personality on surgical wound healing through the use of high-resolution ultrasound. Living kidney donors due to undergo a hand-assisted laparoscopic donor nephrectomy were asked to complete the Perceived Stress Scale, the Life Orientation Test-Revised and the Ten Item Personality Inventory prior to surgery. High-resolution ultrasound scans of surgical wounds were performed on the first three post-operative days and once following discharge (mean=15.3 days; s.d. 2.8). Two measurements from each image were obtained: wound width (size of wound) and median intensity (a marker of tissue fluid). Latent Growth Curve Models (LGCMs) were used to evaluate wound healing. 52 living kidney donors participated. Higher pre-operative life stress, lower optimism and lower conscientiousness were associated with delayed wound healing in living kidney donors for both outcomes. Increased emotional stability was associated with faster wound healing as demonstrated by a change in median intensity. Possible confounding factors, such as age, BMI, smoking status, local anaesthetic use and wound drain placement were not influential. This study, which measured wound healing in a novel patient sample using a novel technique, has demonstrated a negative association between stress and wound healing and the positive influence of optimism, conscientiousness and emotional stability. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Subclinical Synovitis Measured by Ultrasound in Rheumatoid Arthritis Patients With Clinical Remission Induced by Synthetic and Biological Modifying Disease Drugs.

    Science.gov (United States)

    Cruces, Marcos; Al Snih, Soham; Serra-Bonett, Natalí; Rivas, Juan C

    2017-10-09

    Rheumatoid arthritis (RA) patients with disease in clinical remission might show subclinical synovitis, which can be related to the progress of structural joint damage. To determine and compare the degree of synovial inflammation by ultrasound (US) in patients with RA in clinical remission, treated with DMARD or combination therapy with DMARD and anti-TNF. Hospital-based cross-sectional study of 58 patients with RA in sustained remission for at least 6 months by DAS28 <2.6, who attended the Rheumatology Service at the Hospital Universitario de Caracas. Patients underwent clinical, functional, and laboratory assessments. Ultrasound was performed in hands measuring synovial effusion, synovial hypertrophy and power Doppler signal; using a semiquantitative 4-point scale of 0=none to 3=severe. Chi-square and t-test were used to compare the clinical, functional, laboratory and US assessments between the DMARD (N=37) and combination therapy with DMARD and anti-TNF (N=21) groups. A p-value <0.05 was considered statistically significant. Out of 58 patients, 25.9% had remission by US and 74.1% had synovial effusion or hypertrophy or positive power Doppler signal. Non-significant differences in US synovitis between the two groups were found. Persistent US activity was evident in a high percentage of rheumatoid arthritis patients in clinical remission by DAS28. No differences in subclinical synovitis measured by US were found between patients with DMARD and anti-TNF-induced clinical remission. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams are also used to ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic pain abnormal ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... your knees toward your chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... right in front of the rectum. top of page What are some common uses of the procedure? A ... ultrasound to clean out the bowel. top of page What does the equipment look like? Ultrasound scanners consist ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... depth investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a finger – is ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... abnormal growth within the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of ... show up well on x-ray images. Ultrasound causes no health problems and may be repeated as ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Transvaginal ultrasound is performed very much like a gynecologic exam and involves the insertion of the transducer ... with your feet in stirrups similar to a gynecologic exam. Transrectal: For a transrectal ultrasound, a protective ...

  4. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    Directory of Open Access Journals (Sweden)

    Maria Magdalena Dresler

    2017-06-01

    Full Text Available Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.

  5. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  11. Comparison of measurements of the uterus and cervix obtained by magnetic resonance and transabdominal ultrasound imaging to identify the brachytherapy target in patients with cervix cancer.

    Science.gov (United States)

    van Dyk, Sylvia; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash

    2014-03-15

    To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (± SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (± 3.353) mm to 3.7 (± 3.856) mm, and -1.46 (± 3.308) mm to 0.47 (± 3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  12. Comparison of Measurements of the Uterus and Cervix Obtained by Magnetic Resonance and Transabdominal Ultrasound Imaging to Identify the Brachytherapy Target in Patients With Cervix Cancer

    International Nuclear Information System (INIS)

    Dyk, Sylvia van; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash

    2014-01-01

    Purpose: To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Methods and Materials: Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. Results: A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (±SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (±3.353) mm to 3.7 (±3.856) mm, and −1.46 (±3.308) mm to 0.47 (±3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Conclusion: Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer

  13. Comparison of Measurements of the Uterus and Cervix Obtained by Magnetic Resonance and Transabdominal Ultrasound Imaging to Identify the Brachytherapy Target in Patients With Cervix Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Sylvia van, E-mail: sylvia.vandyk@petermac.org [Radiation Therapy Services, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Kondalsamy-Chennakesavan, Srinivas [Rural Clinical School, University of Queensland, Toowoomba, Queensland (Australia); Schneider, Michal [Department of Medical Imaging and Radiation Science, Monash University, Clayton, Victoria (Australia); Bernshaw, David [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Narayan, Kailash [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Department of Obstetrics and Gynaecology, Melbourne University, Melbourne, Victoria (Australia)

    2014-03-15

    Purpose: To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Methods and Materials: Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. Results: A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (±SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (±3.353) mm to 3.7 (±3.856) mm, and −1.46 (±3.308) mm to 0.47 (±3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Conclusion: Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer.

  14. Ultrasound, physical examination, and CA 125 measurement for the detection of recurrence after conservative surgery for early borderline ovarian tumors.

    Science.gov (United States)

    Zanetta, G; Rota, S; Lissoni, A; Meni, A; Brancatelli, G; Buda, A

    2001-04-01

    Borderline ovarian tumors often affect women of childbearing age and the prognosis is outstanding. Given the young age of several patients and the good prognosis, fertility-sparing surgery is considered adequate for stage I tumors. However, women treated conservatively have a relatively small but well-defined risk of recurrence and no study has specifically addressed the optimal follow-up technique. From 1981 to 1997, 164 women underwent fertility-sparing surgery for stage I borderline ovarian tumor and were followed prospectively. After surgery all women underwent physical examination and ultrasound examination every 3 months for 2 years after first diagnosis and every 6 months thereafter. Measurement of serum CA 125 levels was planned every 6 months in patients with a serous tumor. With a median follow-up of 71, months 28 women treated with fertility-sparing surgery (28/164 = 17%) had either recurrence of borderline tumor (23) or recurrence with carcinoma. Complete details of follow-up procedures are available for 24 women and they represent the study population. An abnormal adnexal mass was detected in 18 of 19 women with recurrent borderline tumor. One patient had diagnosis due to persistent free fluid. All five women with invasive carcinoma had diagnosis of a complex adnexal mass. Gynecologic examination was suspicious (palpable mass) in 7 cases and obviously abnormal (large mass or nodules) in another 7. CA 125 serum levels were elevated in 8 cases. Transvaginal ultrasound is currently the most effective diagnostic technique for the follow-up of young patients treated conservatively for early borderline ovarian tumor. Copyright 2001 Academic Press.

  15. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  16. Fulminant intravascular lymphomatosis mimicking acute haemorrhagic leukoencephalopathy.

    Science.gov (United States)

    Marino, D; Sicurelli, F; Cerase, A; Tripodi, S; Cintorino, M; Lazzi, S; Federico, A

    2012-09-15

    Intravascular lymphomatosis (IVL) is a rare non-Hodgkin's lymphoma, usually of B cell lineage, characterized by massive angiotropic growth. The clinical presentation of IVL may include changes in mental status, non-localizing neurological deficits, seizures, fever of unknown origin and skin changes. Because of its rarity and the absence of specific diagnostic procedures except for cerebral biopsy, diagnosis is often postmortem. Brain MRI usually shows non-specific abnormalities. The purpose of this case report is to increase the knowledge of clinical and neuroimaging features of IVL by describing the findings observed in a 71-year-old patient. A 71-year-old male was admitted for right hemiparesis, acute cognitive impairment and febricula. A bone marrow biopsy resulted normal. He then developed a rapid progressive impairment of his mental status and left hemisoma motor seizures. Brain CT and MRI were interpreted as consistent with acute haemorrhagic leukoencephalopathy (AHLE), including multiple areas of restricted diffusion without gadolinium enhancement and a small focal area of gadolinium enhancement in the left temporal lobe white matter. The patient died within a few days and the autopsy led to the diagnosis of IVL. IVL may present with a variety of clinical signs and symptoms, including stroke and hemiparesis. IVL may mimic AHLE at brain MRI. However, the evidence of multiple areas of restricted diffusion without gadolinium enhancement and of a small area of gadolinium enhancement could have led to the correct diagnosis. IVL should be added to the differential diagnosis of AHLE at brain MRI. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Assessment of Primary Care Physicians' Use of a Pocket Ultrasound Device to Measure Left Ventricular Mass in Patients with Hypertension.

    Science.gov (United States)

    Bornemann, Paul; Johnson, Jeremy; Tiglao, Samuel; Moghul, Amina; Swain, Sheila; Bornemann, Gina; Lustik, Mike

    2015-01-01

    Left ventricular hypertrophy (LVH) is common in primary care and is associated with increased morbidity and mortality. Treatment of underlying hypertension can reverse LVH and eliminate the associated risks. Electrocardiography is widely available and commonly used to screen hypertensive patients for LVH, but it is limited by low sensitivity. Limited echocardiographic measurement of the left ventricle is a method for screening with improved sensitivity; however, it is not currently widely used in the primary care setting. This study attempts to test the accuracy of primary care physicians' (PCPs) measurements of the left ventricle using a pocket-sized ultrasound (pUS) device after a brief training session. This study was performed in an outpatient cardiology clinic by 3 family medicine residents and 1 family medicine faculty member after a 4-hour training session. Measurements of the left ventricle were made by PCPs using a pUS device; these measurements were compared with cardiologists' measurements from images obtained by echocardiography technicians. Left ventricular mass index (LVMI) was calculated based on these measurements and then compared between groups. There was no statistically significant difference between the mean LVMI calculations in the 2 groups. The agreement in measurements between the groups, however, showed high variability. This was manifested by the low sensitivity (70%) and specificity (76%) of PCPs in the detection of LVH. This study showed that limited echocardiography for the detection of LVH performed by PCPs at the point of care was feasible. Future studies are needed to determine the ideal training and experience necessary to yield competency. © Copyright 2015 by the American Board of Family Medicine.

  18. The Effect of Diacutaneous Fibrolysis on Patellar Position Measured Using Ultrasound Scanning in Patellofemoral Pain Syndrome Patients.

    Science.gov (United States)

    Fanlo-Mazas, Pablo; Bueno-Gracia, Elena; de Escudero-Zapico, Alazne Ruiz; Tricás-Moreno, José Miguel; Lucha-López, María Orosia

    2018-04-13

    Tightness or lack of flexibility of flexibility of several muscles of the thigh has been associated with patellofemoral-join pain. A tight iliotibial band can lead to laterally located patella and an abnormal patellar tracking pattern. Diacutaneous fibrolysis is commonly used to reduce muscle tightness, but no studies have evaluated the effects of this technique in the treatment of patellofemoral pain syndrome patients. To assess the effect of diacutaneous fibrolysis on patellar position in patients with patellofemoral pain syndrome. A single-group, pretest-posttest clinical trial. University of Zaragoza. 46 subjects with patellofemoral pain (20 males, 26 females (age 27.8 ± 6.9 years)). 3 sessions of diacutaneous fibrolysis. Patellar position measurement using real time ultrasound scanning, pain intensity measured with visual analogue scale and function measured with the Anterior Knee Pain Scale. The application of three sessions of diacutaneous fibrolysis significantly increased the patellar position at post-treatment evaluation (pdiacutaneous fibrolysis and at one week follow up.

  19. An improved approach for accurate and efficient measurement of common carotid artery intima-media thickness in ultrasound images.

    Science.gov (United States)

    Li, Qiang; Zhang, Wei; Guan, Xin; Bai, Yu; Jia, Jing

    2014-01-01

    The intima-media thickness (IMT) of common carotid artery (CCA) can serve as an important indicator for the assessment of cardiovascular diseases (CVDs). In this paper an improved approach for automatic IMT measurement with low complexity and high accuracy is presented. 100 ultrasound images from 100 patients were tested with the proposed approach. The ground truth (GT) of the IMT was manually measured for six times and averaged, while the automatic segmented (AS) IMT was computed by the algorithm proposed in this paper. The mean difference±standard deviation between AS and GT IMT is 0.0231±0.0348 mm, and the correlation coefficient between them is 0.9629. The computational time is 0.3223 s per image with MATLAB under Windows XP on an Intel Core 2 Duo CPU E7500 @2.93 GHz. The proposed algorithm has the potential to achieve real-time measurement under Visual Studio.

  20. An Improved Approach for Accurate and Efficient Measurement of Common Carotid Artery Intima-Media Thickness in Ultrasound Images

    Directory of Open Access Journals (Sweden)

    Qiang Li

    2014-01-01

    Full Text Available The intima-media thickness (IMT of common carotid artery (CCA can serve as an important indicator for the assessment of cardiovascular diseases (CVDs. In this paper an improved approach for automatic IMT measurement with low complexity and high accuracy is presented. 100 ultrasound images from 100 patients were tested with the proposed approach. The ground truth (GT of the IMT was manually measured for six times and averaged, while the automatic segmented (AS IMT was computed by the algorithm proposed in this paper. The mean difference ± standard deviation between AS and GT IMT is 0.0231 ± 0.0348 mm, and the correlation coefficient between them is 0.9629. The computational time is 0.3223 s per image with MATLAB under Windows XP on an Intel Core 2 Duo CPU E7500 @2.93 GHz. The proposed algorithm has the potential to achieve real-time measurement under Visual Studio.

  1. The Clinical Atlas of Intravascular Optical Coherence Tomography for iPad

    DEFF Research Database (Denmark)

    Radu, Maria D

    2012-01-01

    The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing.......The first comprehensive educational tool devoted exclusively to intravascular OCT is now available from PCR publishing....

  2. Low molecular weight heparin attenuates multiple organ failure in a murine model of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Slofstra, Sjoukje H.; van 't Veer, Cornelis; Buurman, Wim A.; Reitsma, Pieter H.; ten Cate, Hugo; Spek, C. Arnold

    2005-01-01

    OBJECTIVE: Bacterial sepsis causes widespread vascular inflammation that frequently leads to disseminated intravascular coagulation (DIC). Although intravascular coagulation contributes to organ failure, it is often debated whether anticoagulant therapy produces any beneficial effects in patients

  3. A maximum likelihood method for obtaining integrated attenuation from ultrasound transmission mode measurements

    NARCIS (Netherlands)

    Willemink, Rene G.; Manohar, Srirang; Slump, Kees H.; van der Heijden, Ferdi; van Leeuwen, Ton G.

    2008-01-01

    In photoacoustic imaging applications an image is reconstructed of the optical absorption distribution the imaged object. The photoacoustic measurements however are also dependent on acoustic properties of the imaged object. By estimating the acoustic properties from photoacoustic measurements, we

  4. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  5. Estimation of Genetic Parameters for Real-time Ultrasound Measurements for Hanwoo Cows at Different Ages and Pregnancy Status

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2014-02-01

    Full Text Available The purpose of this study was to estimate genetic parameters of ultrasound measurements for longissimus dorsi muscle area (LMA, backfat thickness (BFT, and marbling score (MS in Hanwoo cows (N = 3,062 at the ages between 18 and 42 months. Data were collected from 100 Hanwoo breeding farms in Gyeongbuk province, Korea, in 2007 and 2008. The cows were classified into four different age groups, i.e. 18 to 22 months (the first pregnancy period, 23 to 27 (the first parturition, 28 to 32 (the second pregnancy, and 33 to 42 (the second parturition, respectively. For each age group, a multi-trait animal model was used to estimate variance components and heritabilities of the three traits. The averages of LMA, BFT, and MS measurements across the cows of all age groups were 50.1 cm2, 4.62 mm, and 3.04, respectively and heritability estimates were 0.09, 0.10, and 0.08 for the respective traits. However, when the data were analyzed in different age groups, heritability estimates of LMA and BFT were 0.24 and 0.47, respectively, for the cows of 18 to 22 months of age, and 0.21 for MS in the 28 to 32 months old cows. When the cows of all age groups were used, the estimates of genetic (phenotypic correlations were 0.43 (0.35, −0.06 (0.34 and 0.21 (0.32 between LMA and BFT, LMA and MS, and BFT and MS, respectively. However, in the cow age group between 28 and 32 (18 and 22 months, the estimates of genetic (phenotypic correlations were 0.05 (0.29, −0.15 (0.24 and 0.38 (0.24, for the respective pairs of traits. These results suggest that genetic, environmental, and phenotypic variations differ depending on cow age, such that care must be taken when ultrasound measurements are applied to selection of cows for meat quality.

  6. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Directory of Open Access Journals (Sweden)

    Zhonghao Wang

    Full Text Available To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM images using Photoshop software and to assess its intraobserver and interobserver reproducibility.Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA, posterior chamber area (PCA, iris cross-section area (ICA and angle recess area (ARA were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV, and intraclass correlation coefficient (ICC.All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001.Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  7. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-07-01

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  8. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular... and Personal Use Therapeutic Devices § 880.5970 Percutaneous, implanted, long-term intravascular catheter. (a) Identification. A percutaneous, implanted, long-term intravascular catheter is a device that...

  9. 21 CFR 880.5965 - Subcutaneous, implanted, intravascular infusion port and catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Subcutaneous, implanted, intravascular infusion... Hospital and Personal Use Therapeutic Devices § 880.5965 Subcutaneous, implanted, intravascular infusion port and catheter. (a) Identification. A subcutaneous, implanted, intravascular infusion port and...

  10. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    Science.gov (United States)

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  11. Urinary Mineral Concentrations in European Pre-Adolescent Children and Their Association with Calcaneal Bone Quantitative Ultrasound Measurements

    Directory of Open Access Journals (Sweden)

    Karen Van den Bussche

    2016-05-01

    Full Text Available This study investigates differences and associations between urinary mineral concentrations and calcaneal bone measures assessed by quantitative ultrasonography (QUS in 4322 children (3.1–11.9 years, 50.6% boys from seven European countries. Urinary mineral concentrations and calcaneal QUS parameters differed significantly across countries. Clustering revealed a lower stiffness index (SI in children with low and medium urinary mineral concentrations, and a higher SI in children with high urinary mineral concentrations. Urinary sodium (uNa was positively correlated with urinary calcium (uCa, and was positively associated with broadband ultrasound attenuation and SI after adjustment for age, sex and fat-free mass. Urinary potassium (uK was negatively correlated with uCa but positively associated with speed of sound after adjustment. No association was found between uCa and QUS parameters after adjustment, but when additionally adjusting for uNa, uCa was negatively associated with SI. Our findings suggest that urinary mineral concentrations are associated with calcaneal QUS parameters and may therefore implicate bone properties. These findings should be confirmed in longitudinal studies that include the food intake and repeated measurement of urinary mineral concentrations to better estimate usual intake and minimize bias.

  12. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Science.gov (United States)

    Wang, Zhonghao; Liang, Xuanwei; Wu, Ziqiang; Lin, Jialiu; Huang, Jingjing

    2015-01-01

    To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility. Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC). All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (pPhotoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  13. Correlation between magnetic resonance imaging and ultrasound measurements of eye muscle thickness in thyroid-associated orbitopathy.

    Science.gov (United States)

    Karhanova, Marta; Kovar, Radim; Frysak, Zdenek; Sin, Martin; Zapletalova, Jana; Rehak, Jiri; Herman, Miroslav

    2015-06-01

    To compare ultrasound (US) and magnetic resonance imaging (MRI) measurements of horizontal eye muscle thickness in patients with thyroid-associated orbitopathy (TAO) and to compare these measurements according to the phase of the disease, the severity of exophthalmos, and the experience of the investigator. A total of 180 orbits of adult patients with TAO were investigated from May 2007 to December 2012. In addition to their general ophthalmic examination, all patients underwent ultrasonographic measurement of horizontal eye muscle thickness with the B-scan technique and MRI examination of the orbit. Correlations between values obtained by US and MRI were determined for different subgroups according to disease activity (active, inactive), exophthalmos values (Hertel 22 mm), and the time period of examination (2007-2009; 2010-2012). Positive moderate correlation between US and MRI values for the medial rectus muscle (MRM; r = 0.690) and for the lateral rectus muscle (LRM; r = 0.572) was found. Significantly higher correlation was found for the MRM (P < 0.0001) and the LRM (P = 0.0008) in the time period 2010-2012 than in that of 2007-2009. Increasing correlation was found for MRM with increasing values of exophthalmos but this increase was not statistically significant. In the active phase of the disease compared to the inactive phase, statistically significant increased correlation (P = 0.019) was found for the LRM. Ultrasonographic measurement of horizontal eye muscles thickness in TAO moderately correlates with values obtained using MRI. The accuracy of ultrasonographic measurements in particular increases with the experience of the investigator.

  14. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient...

  15. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  16. Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

    Science.gov (United States)

    Çağlar, Çağatay; Kocamış, Sücattin İlker; Demir, Emre; Durmuş, Mustafa

    2017-06-01

    To investigate the accuracy of the measurements of Nidek AL-Scan by comparing with Sirius (CSO, Florence, Italy), a corneal tomography which also employs the Scheimpflug principle, and a commonly used device, ultrasound biometry (UB) (Aviso A/B, Quantel Medical, MT, USA). Right eyes of 85 healthy volunteers (58 women 27 men) with a mean age of 39.24 ± 14.37 years (range 15-68) were enrolled into this comparative prospective study. Average K 2.4, average K 3.3, CCT (central corneal thickness), WTW (white to white distance), ACD (anterior chamber depth) and AL (axial length) were obtained from the AL-Scan and compared with average SimK, CCT, WTW (horizontal anterior chamber diameter) and ACD obtained from Sirius and also compared with ACD and AL obtained from UB. The statistically significant difference was found between all of the measurements (p ACD parameter of AL-Scan and UB showed a perfect correlation (ICC = 0.977), there was a moderate correlation between AL-Scan and Sirius and also between UB and Sirius (ICC = 0.608 and 0.664, respectively). There was a high correlation between the all measurements, besides ACD, of AL-Scan and Sirius and they can be used interchangeably for average keratometry and WTW confidently. However, ACD and CCT have a broader 95 % LoA (-0.039 to 0.744 and -24.985 to 3.691, respectively). In addition, AL-Scan and UB were in good agreement regarding ACD, while differences in AL measurements of UB and AL-Scan were clinically important (95 % LoA = -0.091 to 0.703). Furthermore, UB and Sirius have a moderate agreement regarding ACD (95 % LoA = -0.047 to 0.680).

  17. Determination of tissue thermal conductivity by measuring and modeling temperature rise induced in tissue by pulsed focused ultrasound.

    Science.gov (United States)

    Kujawska, Tamara; Secomski, Wojciech; Kruglenko, Eleonora; Krawczyk, Kazimierz; Nowicki, Andrzej

    2014-01-01

    A tissue thermal conductivity (Ks) is an important parameter which knowledge is essential whenever thermal fields induced in selected organs are predicted. The main objective of this study was to develop an alternative ultrasonic method for determining Ks of tissues in vitro suitable for living tissues. First, the method involves measuring of temperature-time T(t) rises induced in a tested tissue sample by a pulsed focused ultrasound with measured acoustic properties using thermocouples located on the acoustic beam axis. Measurements were performed for 20-cycle tone bursts with a 2 MHz frequency, 0.2 duty-cycle and 3 different initial pressures corresponding to average acoustic powers equal to 0.7 W, 1.4 W and 2.1 W generated from a circular focused transducer with a diameter of 15 mm and f-number of 1.7 in a two-layer system of media: water/beef liver. Measurement results allowed to determine position of maximum heating located inside the beef liver. It was found that this position is at the same axial distance from the source as the maximum peak-peak pressure calculated for each nonlinear beam produced in the two-layer system of media. Then, the method involves modeling of T(t) at the point of maximum heating and fitting it to the experimental data by adjusting Ks. The averaged value of Ks determined by the proposed method was found to be 0.5±0.02 W/(m·°C) being in good agreement with values determined by other methods. The proposed method is suitable for determining Ks of some animal tissues in vivo (for example a rat liver).

  18. Determination of tissue thermal conductivity by measuring and modeling temperature rise induced in tissue by pulsed focused ultrasound.

    Directory of Open Access Journals (Sweden)

    Tamara Kujawska

    Full Text Available A tissue thermal conductivity (Ks is an important parameter which knowledge is essential whenever thermal fields induced in selected organs are predicted. The main objective of this study was to develop an alternative ultrasonic method for determining Ks of tissues in vitro suitable for living tissues. First, the method involves measuring of temperature-time T(t rises induced in a tested tissue sample by a pulsed focused ultrasound with measured acoustic properties using thermocouples located on the acoustic beam axis. Measurements were performed for 20-cycle tone bursts with a 2 MHz frequency, 0.2 duty-cycle and 3 different initial pressures corresponding to average acoustic powers equal to 0.7 W, 1.4 W and 2.1 W generated from a circular focused transducer with a diameter of 15 mm and f-number of 1.7 in a two-layer system of media: water/beef liver. Measurement results allowed to determine position of maximum heating located inside the beef liver. It was found that this position is at the same axial distance from the source as the maximum peak-peak pressure calculated for each nonlinear beam produced in the two-layer system of media. Then, the method involves modeling of T(t at the point of maximum heating and fitting it to the experimental data by adjusting Ks. The averaged value of Ks determined by the proposed method was found to be 0.5±0.02 W/(m·°C being in good agreement with values determined by other methods. The proposed method is suitable for determining Ks of some animal tissues in vivo (for example a rat liver.

  19. Structural linear measurements in the newborn brain: accuracy of cranial ultrasound compared to MRI

    International Nuclear Information System (INIS)

    Leijser, Lara M.; Srinivasan, Latha; Cowan, Frances M.; Rutherford, Mary A.; Counsell, Serena J.; Allsop, Joanna M.

    2007-01-01

    Structural size in the neonatal brain is of clinical importance. Cranial ultrasonography (cUS) is the primary method used for evaluating the neonatal brain and it is important to know whether linear measurements made using this technique are accurate. To compare linear measurements of different cerebral structures made from neonatal cUS and contemporaneous MRI. Preterm and term infants studies with cUS and MRI on the same day were studied. Linear measurements made using both techniques from many cerebral structures were compared using a paired t-test. A total of 44 sets of scans from 26 preterm and 8 term infants were assessed. Small but significant differences between the cUS and MRI measurements (P<0.05) were found for the ventricular index, the posterior horn depth of the lateral ventricle, the extracerebral space and interhemispheric fissure, and the cortex of the cingulate gyrus. No significant differences were found for any other measurements. Linear measurements from cUS are accurate for most neonatal cerebral structures. Significant differences compared to MRI were found for a few structures, but only for the cortex were the absolute differences marked and possibly of clinical importance. (orig.)

  20. Structural linear measurements in the newborn brain: accuracy of cranial ultrasound compared to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Leijser, Lara M. [Hammersmith Hospital, Imperial College, Department of Paediatrics, London (United Kingdom); Srinivasan, Latha; Cowan, Frances M. [Hammersmith Hospital, Imperial College, Department of Paediatrics, London (United Kingdom); Hammersmith Hospital, Imperial College, Department of Imaging Sciences, London (United Kingdom); Rutherford, Mary A.; Counsell, Serena J.; Allsop, Joanna M. [Hammersmith Hospital, Imperial College, Department of Imaging Sciences, London (United Kingdom)

    2007-07-15

    Structural size in the neonatal brain is of clinical importance. Cranial ultrasonography (cUS) is the primary method used for evaluating the neonatal brain and it is important to know whether linear measurements made using this technique are accurate. To compare linear measurements of different cerebral structures made from neonatal cUS and contemporaneous MRI. Preterm and term infants studies with cUS and MRI on the same day were studied. Linear measurements made using both techniques from many cerebral structures were compared using a paired t-test. A total of 44 sets of scans from 26 preterm and 8 term infants were assessed. Small but significant differences between the cUS and MRI measurements (P<0.05) were found for the ventricular index, the posterior horn depth of the lateral ventricle, the extracerebral space and interhemispheric fissure, and the cortex of the cingulate gyrus. No significant differences were found for any other measurements. Linear measurements from cUS are accurate for most neonatal cerebral structures. Significant differences compared to MRI were found for a few structures, but only for the cortex were the absolute differences marked and possibly of clinical importance. (orig.)

  1. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  2. Using the ultrasound and instrumented indentation techniques to measure the elastic modulus of engineering materials

    International Nuclear Information System (INIS)

    Meza, J. M.; Franco, E. E.; Farias, M. C. M.; Buiochi, F.; Souza, R. M.; Cruz, J.

    2008-01-01

    Currently, the acoustic and nano indentation techniques are two of the most used techniques for materials elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nano indentation technique are also reviewed. an experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nano indentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained. (Author) 29 refs

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  4. CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND MEASUREMENTS DURING AND AFTER EXERCISE

    NARCIS (Netherlands)

    VANLEEUWEN, BE; BARENDSEN, GJ; LUBBERS, J; DEPATER, L

    To investigate the joint effects of body posture and calf muscle pump, the calf blood flow of eight healthy volunteers was measured with pulsed Doppler equipment during and after 3 min of rhythmic exercise on a calf ergometer in the supine, sitting, and standing postures. Muscle contractions

  5. Transabdominal ultrasound for standardized measurement of bowel wall thickness in normal children and those with Crohn's disease.

    Science.gov (United States)

    Chiorean, Liliana; Schreiber-Dietrich, Dagmar; Braden, Barbara; Cui, XinWu; Dietrich, Christoph F

    2014-12-01

    The intestinal wall can be visualized using high resolution transabdominal ultrasound (TUS). TTUS measurement of the bowel wall thickness has been described in adults but data are lacking in children. The purpose of this prospective study was to sonographically investigate bowel wall thickness in healthy children and children with Crohn's disease. TUS (5-15 MHz) of the intestine was performed in 58 healthy children (age range 3 to 16 years) and in 30 children with Crohn's disease (age range 8 to 17 years). The following regions were assessed and bowel wall thickness measured: terminal ileum, cecum, right flexure, and sigmoid colon. In patients with Crohn's disease, the involved region was additionally assessed regarding length of involved segment and sonographic signs of transmural inflammation and fistula. TUS allowed adequate measurement of bowel wall thickness in all 58 healthy children (100%) and in all 30 Crohn's disease patients (100%). The bowel wall thickness significantly differed between groups. Bowel wall thickness (mean +/- SD) in all segments was less then 2 mm in all healthy children (1.0+/-0.1 mm terminal ileum, 1.1+/-0.1 mm cecum, 1.1+/-0.1 mm right flexure, and 1.3+/-0.1 mm sigmoid colon). In Crohn's disease patients, bowel wall thickness was ≥ 3 mm in the ileocecal region and was significantly increased (5.1+/-1.9 mm) compared to the healthy children. The mean length of involved segment was 15+/-6.5 cm [5 - 30 cm]. Additional findings in Crohn's disease patients were: transmural inflamation (3/30), interenteric fistula (3/30), gastrocolic fistula (1/30) and vesicoenteric fistula (1/30). Similar to adults, normal bowel wall thickness in children is always less than 2 mm. In all patients with Crohn's disease, increased bowel wall thickness could be detected. TUS is a helpful tool in the diagnosis and assessment of activity and complications in Crohn's disease.

  6. Measurement considerations on examiner-dependent factors in the ultrasound assessment of developmental dysplasia of the hip.

    Science.gov (United States)

    Kolb, Alexander; Benca, Emir; Willegger, Madeleine; Puchner, Stephan E; Windhager, Reinhard; Chiari, Catharina

    2017-06-01

    The standardized sonographic hip screening according to Graf has increased reliability and comparability of measurements in the screening of developmental dysplasia of the hip (DDH). However, examiner dependent factors have been discussed to influence sonographic measurements. The objectives of this study were to examine the tolerance of the transducer positioning and to analyse the impact of transducer inclinations on Graf's hip grading system. Twenty-four hips in consecutive newborns were screened sonographically in combination with an optoelectronic motion capture system to trace transducer positions in space. Subsequently five defined inclinations of the transducer relative to Graf's neutral transducer position were analysed, giving a total of 144 sonographic images. We found a permissible transducer inclination in the axial plane of 8.8° to anterior and 8.1° to posterior. In the frontal plane we found a permissible inclination of 15.4° to caudal and 7.2° to cranial. The impact on the α-angle was significant for posterior-cranial (p < 0.001), cranial (p = 0.009), and caudal (p < 0.001) inclined transducer positions. The effect on the results according to Graf's grading system was significant for the caudal inclination of the transducer position (p < 0.001). Our findings show that the standardized plane defined by Graf's criteria allows notable inclinations of the transducer positions. Transducer inclinations show an impact on measurement results, which are clinically relevant. Those effects cannot be ruled out using Graf's ultrasound criteria alone. The examiner should pay attention to avoid transducer inclinations in the frontal plane and a combination of posterior and cranial inclination.

  7. 21 CFR 880.5440 - Intravascular administration set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular administration set. 880.5440 Section 880.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use...

  8. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  9. Disseminated intravascular coagulation in malaria: A case report ...

    African Journals Online (AJOL)

    Disseminated intravascular coagulation (DIC) is seen in <5% of patients with severe Plasmodium falciparum malaria and is more common in cerebral malaria. Here, we report the diagnosis and management of a case of severe P. falciparum malaria with DIC. Keywords: Cerebral malaria, cytokine storm, DIC, heparin ...

  10. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  11. Intravascular catheter sepsis | Mer | South African Medical Journal

    African Journals Online (AJOL)

    Intravascular devices are an integral component of modern-day medical practice. They are used to administer intravenous fluids, medications, blood products and parenteral nutrition. In addition, they serve as a valuable monitor of the haemodynamic status of critically ill patients.

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  14. Assessment of voluntary pelvic floor muscle contraction in continent and incontinent women using transperineal ultrasound, manual muscle testing and vaginal squeeze pressure measurements.

    Science.gov (United States)

    Thompson, Judith A; O'Sullivan, Peter B; Briffa, N Kathryn; Neumann, Patricia

    2006-11-01

    The aims of the study were: (1) to assess women performing voluntary pelvic floor muscle (PFM) contractions, on initial instruction without biofeedback teaching, using transperineal ultrasound, manual muscle testing, and perineometry and (2) to assess for associations between the different measurements of PFM function. Sixty continent (30 nulliparous and 30 parous) and 60 incontinent (30 stress urinary incontinence (SUI) and 30 urge urinary incontinence (UUI)) women were assessed. Bladder neck depression during attempts to perform an elevating pelvic floor muscle (PFM) contraction occurred in 17% of continent and 30% of incontinent women. The UUI group had the highest proportion of women who depressed the bladder neck (40%), although this was not statistically significant (p=0.060). The continent women were stronger on manual muscle testing (p=0.001) and perineometry (p=0.019) and had greater PFM endurance (pelevation than the incontinent women (p=0.051). There was a moderate correlation between bladder neck movement during PFM contraction measured by ultrasound and PFM strength assessed by manual muscle testing (r=0.58, p=0.01) and perineometry (r=0.43, p=0.01). The observation that many women were performing PFM exercises incorrectly reinforces the need for individual PFM assessment with a skilled practitioner. The significant correlation between the measurements of bladder neck elevation during PFM contraction and PFM strength measured using MMT and perineometry supports the use of ultrasound in the assessment of PFM function; however, the correlation was only moderate and, therefore, indicates that the different measurement tools assess different aspects of PFM function. It is recommended that physiotherapists use a combination of assessment tools to evaluate the different aspects of PFM function that are important for continence. Ultrasound is useful to determine the direction of pelvic floor movement in the clinical assessment of pelvic floor muscle function

  15. Ultrasound measurement of visceral fat in patients with primary biliary cirrhosis

    Directory of Open Access Journals (Sweden)

    Alempijević Tamara

    2011-01-01

    Full Text Available Background/Aim. Primary biliary cirrhosis (PBC is a progressive, chronic liver disease with elevated serum lipids, but it is unclear whether hyperlipidemia in PBC patients is associated with atherosclerosis. Metabolic syndrome promotes development of atherosclerotic cardiovascular disease related to abdominal type obesity and insulin resistance. The aim of our study was to assess abdominal adiposity in patients with PBC. Methods. The study included 40 patients with PBC and 50 healthy controls. Age, sex and anthropometric measurements (weight, height, body mass index and waist circumference were registered for all patients and controls. We used ultrasonography to measure subcutaneous (SF and visceral fat (VF diameter, subcutaneous area (SA and visceral area (VA, as well as perirenal fat diameter (PF. Results. Values of SF, VF and PF thicknesses in PBC patients were 19.23 ± 5.85 mm, 10.92 ± 3.63 mm, and 7.03 ± 1.82 mm, respectively. In controls these measurements were 22.73 ± 6.70 mm, 16.84 ± 5.51 mm and 10.50 ± 2.70 mm respectively. In PBC patients SA and VA were calculated to 983.64 ± 322.68 mm2 and 403.64 ± 166.97 mm2 and in controls 1124.89 ± 366.01 mm2 and 720.57 ± 272.50 mm2 respectrively. Significant difference was found for VF, VA and RF values. Conclusions. Considering that the amount of visceral fat plays an important role in development of metabolic syndrome and cardiovascular diseases, we concluded that the lower amount of visceral fat in PBC patients could be related to lower incidence of cardiovascular events, despite hyperlipidemia.

  16. Ultrasound Characterization of Microbead and Cell Suspensions by Speed of Sound Measurements of Neutrally Buoyant Samples

    DEFF Research Database (Denmark)

    Cushing, Kevin W.; Garofalo, Fabio; Magnusson, Cecilia

    2017-01-01

    . The density of the microparticles is determined by using a neutrally buoyant selection process that involves centrifuging of microparticles suspended in different density solutions, CsCl for microbeads and Percoll for cells. The speed of sound at 3 MHz in the neutrally buoyant suspensions is measured...... and fixed cells, such as red blood cells, white blood cells, DU-145 prostate cancer cells, MCF-7 breast cancer cells, and LU-HNSCC-25 head and-neck squamous carcinoma cells in phosphate buffered saline. The results show agreement with published data obtained by other methods....

  17. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  18. Ultrasound measurement of abdominal muscles during clinical isometric endurance tests in women with and without low back pain.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Ebrahimi, Esmaeil; ShahAli, Shiva; Rahmani, Nahid; Negahban, Hossein; Kazemnejad, Anoshirvan; Bahmani, Andia

    2018-02-26

    The present study investigated group differences between the thickness changes of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles, during performance of the isometric supine chest raise and the supine double leg-straight leg raise tests in women with and without low back pain (LBP). Twenty women with LBP and 20 women without LBP participated in this case-control study. The thickness of the right TrA, IO, and EO muscles was measured using B-mode ultrasound (US) at rest, immediately at the beginning of performing the tests and when participants in both groups self-reported fatigue. The percentage of change in thickness of the abdominal muscles from rest to the initiation and fatigue stages of both tests was measured. The results indicate a statistically significant difference in the pattern of changes in deep (TrA) and superficial (EO) abdominal muscles thickness at the fatigue stage of the supine double straight-leg raise (SDSLR) test between groups (P abdominal muscles thicknesses change at rest or during stages of the clinical isometric endurance tests (P > 0.05). An altered activation pattern in the deep (TrA) and superficial (EO) muscles of LBP participants during fatigue stage of the SDSLR test as compared to controls indicates motor control dysfunction in the LBP group. Comparison of the activity of TrA and EO muscles during fatigue stage of SDSLR test can be used to assess alterations in motor control of abdominal muscles.

  19. Measurement of misalignment in a journal bearing with low frequency ultrasound

    International Nuclear Information System (INIS)

    Kim, Noh Nu

    1998-01-01

    Misalignment of a shaft in journal bearing of rotary compressor was measured and analyzed for the study on the effect of misalignment on the performance of the rotary compressor using a new ultrasonic pulse-echo technique. Two low-frequency ultrasonic transducers(10Mhz) were mounted on the outer surface of the bearing in X and Y axis to receive the reflection signals from each axis and to obtain the amplitude of a modified reflection wave defined as the total reflection wave minus the first reflection wave from a thin layer which is inversely proportional to the thickness of the layer in the region where h/λ is approximately less than 1/4. The relationship of the amplitude of the modified reflection wave to the thickness of the oil layer was shown both in mathematical form and in graph. Gap clearances between the bearing and the shaft in the horizontal and vertical axis were determined directly by the relationship and used to evaluate the misalignment of the journal bearing. Several intentional misalignments in a test compressor were made to measure and show the misalignment and the effect of the misalignment on the efficiency of the rotary compressor. A fast quantitative evaluation of the misalignment of journal bearing was possible using the amplitude of the modified reflection signal without any inversion process to extract thickness information from waveforms of the reflected waves.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Prostate Ultrasound Imaging? Men who have ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  5. Ultrasound -- Vascular

    Science.gov (United States)

    ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the ... is specialized and is best performed by a technologist and physician with experience in vascular ultrasound imaging. top of page Additional Information and Resources ...

  6. Evaluation of a method to measure water content in porous media by employing ultrasound

    Directory of Open Access Journals (Sweden)

    Luis Leonardo Sáenz Cruz

    2003-01-01

    Full Text Available A method to measure water content in porous media, such as solis and grains, was developed as a real time nondestructive test. The method was based on piezoelectric ultrasonic transducers as a sensor system. Transmiters and receivers was developed to administrate the sensors system and ultrasonic signal. Transmiters and receivers are placed facing each other and located inside the porous media 10 cm apart. The method was evaluated in two porous meda, namely a column 30 cm coarse sand and a paddy rice variety Fedearroz 50, in order to evaluate the sensors system performance in two different porous media with different water holder capacity. Tools were developed for data acquisition, capacity of 16 analog signal, 12 bits resolution. Electronic circuits, C++ OPP programming and Matlab were used. The results showed a monotonically increment of millivolts as a response of the transducer as the water content was decreasing

  7. Ultrasound imaging

    International Nuclear Information System (INIS)

    Grant, E.G.; Doherty, F.J.

    1986-01-01

    Diagnostic ultrasound was used as early as 1950 in attempts to detect malignant tumors within the human breast and brain. In the years following, however, little attention was paid to this method of imaging by the radiologic community. Extensive work with this technique was not begun until the 1960s, when bistable ultrasound enabled sonographers to display organ outlines for the first time. Prior to the development of bistable ultrasound, sonographic images were limited to A-mode displays, which were merely a series of amplitude spikes on a graph. Over the past 20 or so years, major advances in ultrasound technology have gradually taken us from the simple graphic A-mode display, through bistable organ outlines, to gray-scale images with excellent parenchymal detail, and finally to real-time ultrasound

  8. Ultrasound Transmission Tomography for Detecting and Measuring Cylindrical Objects Embedded in Concrete.

    Science.gov (United States)

    Lluveras Núñez, Dalmay; Molero-Armenta, Miguel Ángel; Izquierdo, Miguel Ángel García; Hernández, Margarita González; Anaya Velayos, José Javier

    2017-05-10

    This study explores the feasibility of using transmission tomographic images based on attenuation measures in transmission to detect and estimate the most common materials that are embedded in concrete, reinforcements and natural and artificial voids. A limited set of concrete specimens have been made in which cylindrical objects such as bars/tubes of steel, PVC and aluminium have been embedded to analyse the effect of size and material. The methodology and scope of this study is presented and numerical simulations are carried out to optimize the emitter-receiver configuration and to understand the complex physical propagation phenomena of ultrasonic signals that travel through concrete with embedded inclusions. Experimental tomographic images are obtained by using an ultrasonic tomographic system, which has the advantage of needing only two ultrasonic transducers. Both the software simulation tool and the tomographic inspection system are developed by the authors. The obtained results show that PVC tubes and steel bars of diameters higher than 19 mm and embedded in cylindrical specimens, can be detected and their sizes estimated using segmented tomographic images.

  9. Reliability and validity of an ultrasound-based imaging method for measuring interspinous process distance in the lumbar spine using two different index points.

    Science.gov (United States)

    Tozawa, Ryosuke; Katoh, Munenori; Aramaki, Hidefumi; Kumamoto, Tsuneo; Fujinawa, Osamu

    2015-07-01

    [Purpose] This study assessed the reliability and validity of an ultrasound-based imaging method for measuring the interspinous process distance in the lumbar spine using two different index points. [Subjects and Methods] Ten healthy males were recruited. Five physical therapy students participated in this study as examiners. The L2-L3 interspinous distance was measured from the caudal end of the L2 spinous process to the cranial end of the L3 spinous process (E-E measurement) and from the top of the L2 spinous process to the top of the L3 spinous process (T-T measurement). Intraclass correlation coefficients were calculated to estimate the relative reliability. Validity was assessed using a model resembling the living human body. [Results] The reliability study showed no difference in intra-rater reliability between the two measurements. However, the E-E measurement showed higher inter-rater reliability than the T-T measurement (Intraclass correlation coefficients: 0.914 vs. 0.725). Moreover, the E-E measurement method had good validity (Intraclass correlation coefficients: 0.999 and 95% confidence interval for minimal detectable change: 0.29 mm). [Conclusion] These results demonstrate the high reliability and validity of ultrasound-based imaging in the quantitative assessment of lumbar interspinous process distance. Of the two methods, the E-E measurement method is recommended.

  10. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... waves from passing into the body. The sonographer (ultrasound technologist) or radiologist then gently presses the transducer against ... performed on an infant, a nurse or radiologic technologist may assist with keeping the ... procedure? Ultrasound examinations are painless and easily tolerated by most ...

  11. Assessment of trabecular bone quality in human cadaver calcaneus using scanning confocal ultrasound and dual x-ray absorptiometry (DEXA) measurements

    Science.gov (United States)

    Qin, Yixian; Xia, Yi; Lin, Wei; Rubin, Clinton; Gruber, Barry

    2004-10-01

    Microgravity and aging induced bone loss is a critical skeleton complication, occurring particularly in the weight-supporting skeleton, which leads to osteoporosis and fracture. Advents in quantitative ultrasound (QUS) provide a unique method for evaluating bone strength and density. Using a newly developed scanning confocal acoustic diagnostic (SCAD) system, QUS assessment for bone quality in the real body region was evaluated. A total of 19 human cadaver calcanei, age 66 to 97 years old, were tested by both SCAD and nonscan mode. The scanning region covered an approximate 40×40 mm2 with 0.5 mm resolution. Broadband ultrasound attenuation (BUA, dB/MHz), energy attenuation (ATT, dB), and ultrasound velocity (UV, m/s) were measured. The QUS properties were then correlated to the bone mineral density (BMD) measured by DEXA. Correlations between BMD and QUS parameters were significantly improved by using SCAD as compared to nonscan mode, yielding correlations between BMD and SCAD QUS parameters as R=0.82 (BUA), and R=0.86 (est. BMD). It is suggested that SCAD is feasible for in vivo bone quality mapping. It can be potentially used for monitoring instant changes of bone strength and density. [Work supported by the National Space Biomedical Research Institute (TD00207), and New York Center for Biotechnology.

  12. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Measurement of skull bone thickness for bone-anchored hearing aids: an experimental study comparing both a novel ultrasound system (SonoPointer) and computed tomographic scanning to mechanical measurements.

    Science.gov (United States)

    Federspil, Philipp A; Tretbar, Steffen H; Böhlen, Friederike H; Rohde, Stefan; Glaser, Simon; Plinkert, Peter K

    2010-04-01

    A-mode ultrasound scanning with coded signals allows bone thickness measurements at the site of bone-anchored hearing aid surgery as compared to computed tomographic scanning and mechanical measurements. Adequate bone thickness is a prerequisite for successful, long-lasting osseointegration of titanium fixtures for bone-anchored hearing aids. Computed tomography can be used to measure bone thickness but has several drawbacks. Bone thickness was measured at the site of bone-anchored hearing aids surgery in 28 formaldehyde-preserved human cadaver temporoparietal bones. Four blinded investigators used a hand-held, A-mode ultrasound system with direct coupling at 2.25 MHz transducer using coded signals (SonoPointer) and repeated the measurements twice. Comparisons were made with high-resolution computed tomographic scanning and mechanical micrometer caliper measurements. There was significant anatomical variation in the temporoparietal bones. Computed tomography was in good agreement with the mechanical reference. All specimens could be measured by the SonoPointer. The mean difference between the mechanical control and ultrasound scanning averaged for all measurements by all investigators was 0.3 mm (standard deviation, 1.2 mm). Trained ultrasound experts yielded better results (mean difference, 0.3 mm; standard deviation, 1.0 mm). Agreement was best for bone thickness up to 5 mm. Outliers occurred in bones thicker than 7.5 mm. The SonoPointer is a promising, noninvasive, hand-held tool for real-time measurement of bone thickness in bone-anchored hearing aid surgery, especially for children. Even disregarding the absolute thickness reading, the SonoPointer could be used to search intraoperatively for a local maximum of bone thickness.

  14. Comparison between shear wave dispersion magneto motive ultrasound and transient elastography for measuring tissue-mimicking phantom viscoelasticity.

    Science.gov (United States)

    Almeida, Thiago W J; Sampaio, Diego R Thomaz; Bruno, Alexandre Colello; Pavan, Theo Z; Carneiro, Antonio A O

    2015-12-01

    Several methods have been developed over the last several years to analyze the mechanical properties of soft tissue. Elastography, for example, was proposed to evaluate soft tissue stiffness in an attempt to reduce the need for invasive procedures, such as breast biopsies; however, its qualitative nature and the fact that it is operator-dependent have proven to be limitations of the technique. Quantitative shearwave- based techniques have been proposed to obtain information about tissue stiffness independent of the operator. This paper describes shear wave dispersion magnetomotive ultrasound (SDMMUS), a new shear-wave-based method in which a viscoelastic medium labeled with iron oxide nanoparticles is displaced by an external tone burst magnetic field. As in magnetomotive ultrasound (MMUS), SDMMUS uses ultrasound to detect internal mechanical vibrations induced by the interaction between a magnetic field and magnetic nanoparticles. These vibrations generated shear waves that were evaluated to estimate the viscoelastic properties of tissue-mimicking phantoms. These phantoms were manufactured with different concentrations of gelatin and labeled with iron oxide nanoparticles. The elasticity and viscosity obtained with SDMMUS agreed well with the results obtained by traditional ultrasound-based transient elastography.

  15. Functional intravascular volume deficit in patients before surgery

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Jørgensen, C C; Secher, N H

    2010-01-01

    limited data on the volume required to establish a maximal SV before the start of surgery. Therefore, we estimated the occurrence and size of the potential functional intravascular volume deficit in surgical patients. METHODS: Patients scheduled for mastectomy (n=20), open radical prostatectomy (n=20......BACKGROUND: Stroke volume (SV) maximization with a colloid infusion, referred to as individualized goal-directed therapy, improves outcome in high-risk surgery. The fraction of patients who need intravascular volume to establish a maximal SV has, however, not been evaluated, and there are only...... deficit. RESULTS: Forty-two (70%) of the patients needed volume to establish a maximal SV. For the patients needing volume, the required amount was median 200 ml (range 200-600 ml), with no significant difference between the three groups of patients. The required volume was >or=400 ml in nine patients (15...

  16. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  17. The effect of isometric exercise of the hand on the synovial blood flow in patients with rheumatoid arthritis measured by color Doppler ultrasound

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Torp-Pedersen, Søren; Lund, Hans

    2013-01-01

    made it possible to investigate the direct effect on blood supply in the synovium after training. In this case-control study, 24 patients with RA with USD activity in the wrist joint participated. The USD activity was measured by the color fraction (CF) (CF = colored pixels/total number of pixels......In 90% of patients with rheumatoid arthritis (RA), the joints of the hand are affected. Studies of grip strength training have not indicated a negative effect on disease activity after training. Introduction of ultrasound Doppler (USD) to measure increased blood flow induced by inflammation has...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... whether the object is solid or filled with fluid). In medicine, ultrasound is used to detect changes ... As the sound waves bounce off internal organs, fluids and tissues, the sensitive receiver in the transducer ...

  20. Transvaginal ultrasound

    Science.gov (United States)

    ... bleeding and menstrual problems Certain types of infertility Ectopic pregnancy Pelvic pain Transvaginal ultrasound is also used during ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for ...