WorldWideScience

Sample records for intrauterine system safety

  1. The levonorgestrel-releasing intrauterine system: Safety, efficacy, and patient acceptability

    Directory of Open Access Journals (Sweden)

    Megan N Beatty

    2009-07-01

    Full Text Available Megan N Beatty, Paul D BlumenthalDepartment of Obstetrics and Gynecology, Stanford University, Stanford, CA, USAAbstract: The levonorgestrel-releasing intrauterine system (LNG-IUS is a safe, effective and acceptable form of contraception used by over 150 million women worldwide. It also has a variety of noncontraceptive benefits including treatment for menorrhagia, endometriosis, and endometrial hyperplasia. The LNG-IUS has also been used in combination with estrogen for hormone replacement therapy and as an alternative to hysterectomy. Overall, the system is very well tolerated and patient satisfaction is quite high when proper education regarding possible side effects is provided. However, despite all of the obvious benefits of the LNG-IUS, utilization rates remain quite low in the developed countries, especially in the United States. This is thought to be largely secondary to the persistent negative impressions from the Dalkon Shield intrauterine experience in the 1970s. This history continues to negatively influence the opinions of both patients and health care providers with regards to intrauterine devices. Providers should resolve to educate themselves and their patients on the current indications and uses for this device, as it, and intrauterine contraception in general, remains a largely underutilized approach to a variety of women’s health issues.Keywords: Mirena®, levonorgestrel-releasing, intrauterine system, intrauterine contraceptive device

  2. The intrauterine device and the intrauterine system.

    Science.gov (United States)

    Stephen Searle, E

    2014-08-01

    Intrauterine contraception is used by about 100 million women worldwide, making it the most popular form of fertility regulation. In UK community contraception clinics, however, long-acting reversible contraception has increased to 28% of users, and intrauterine contraception accounts for only 8% of methods used by women accessing these services. Potential exists to increase uptake of these more effective methods. In this chapter, we review the clinical advantages, disadvantages and cost-effectiveness of intrauterine contraception. We discuss the management of complications along with advice for trainers, and briefly consider issues in developing countries. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Comparison of copper intrauterine device with levonorgestrel-bearing intrauterine system for post-abortion contraception.

    Science.gov (United States)

    Bilgehan, Fatma; Dilbaz, Berna; Karadag, Burak; Deveci, Canan Dura

    2015-09-01

    The aim of this study was to compare the safety, bleeding pattern, effects, side-effects, complications and 6-month continuity rates of levonorgestrel-bearing intrauterine system (LNG-IUS) with conventional copper intrauterine device (Cu-IUD) inserted immediately after voluntary termination of pregnancy up to 10 weeks of gestation. One hundred women who underwent voluntary pregnancy termination and preferred IUD insertion as a contraceptive method after counseling were enrolled. The patients were randomly allocated to Cu-IUD or LNG-IUS and followed up at 10 days, and at 1, 3 and 6 months. The expulsion rates, continuation rates, side-effects, and bleeding patterns were compared. Fifty women in the Cu-IUD group and 44 women in the LNG-IUS group were followed up. The continuity and expulsion rate for Cu-IUD and LNG-IUS at the end of 6 months was 74%, 12%, and 75%, 11.3%, respectively. In LNG-IUS users, the incidence of amenorrhea and the number of spotting days were higher and hemoglobin increased throughout the follow-up period. The side-effects related to both methods were not different from interval insertions. Immediate post-abortion intrauterine contraception with Cu-IUD or LNG-IUS is a safe, reliable method. The incidence of side-effects is similar, and there is only a slightly higher rate of expulsion but an acceptable rate of method continuation. © 2015 Japan Society of Obstetrics and Gynecology.

  4. Do intrauterine device/intrauterine system users check their threads?

    Science.gov (United States)

    Davies, Amanda; Fleming, Charlotte

    2014-04-01

    Expulsion of an intrauterine device (IUD) occurs in about 1 in 20 women and expulsion may not be noticed by the user. Current guidance recommends that users are instructed to check regularly for their threads. This is the first study to explore the reality of how women feel about checking their threads and the details surrounding how frequently checks are done. One hundred consecutive IUD users were interviewed regarding their type of device, duration of use, frequency of thread checking, prompts for checking and reasons for not checking. Only 23% checked their threads regularly and 51% had never done so. The most common reason for not checking was forgetting about it. Despite being advised to do so, the majority of users do not check their threads at all and fewer than one-quarter of them check regularly. We propose that advice offered about thread checking should be given less emphasis and suggested more for user reassurance.

  5. Use of levonorgestrel intrauterine system for medical indications in adolescents.

    Science.gov (United States)

    Bayer, Lisa L; Hillard, Paula J Adams

    2013-04-01

    The levonorgestrel intrauterine system (LNG-IUS) is an underused contraceptive method in adolescent populations. In addition to being a highly effective, reversible, long-acting contraception, the LNG-IUS has many noncontraceptive health benefits including reduced menstrual bleeding, decreased dysmenorrhea and pelvic pain related to endometriosis, and menstruation suppression in teens with physical or developmental disabilities. The LNG-IUS can also provide endometrial protection in teens with chronic anovulation, and may be used to treat endometrial hyperplasia and cancer. This review examines the evidence supporting the use of the LNG-IUS in adolescents for these noncontraceptive benefits. Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  6. Role of the levonorgestrel intrauterine system in effective contraception

    Directory of Open Access Journals (Sweden)

    Attia AM

    2013-08-01

    Full Text Available Abdelhamid M Attia,1 Magdy M Ibrahim,1 Ahmed M Abou-Setta21Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt; 2George and Fay Yee Centre for Healthcare Innovation, University of Manitoba/Winnipeg Regional Health Authority, Winnipeg, MB, CanadaAbstract: Norgestrel, a synthetic progestin chemically derived from 19-nortestosterone, is six times more potent than progesterone, with variable binding affinity to various steroid receptors. The levonorgestrel-releasing intrauterine system (LNG IUS provides a long-acting, highly effective, and reversible form of contraception, with a pearl index of 0.18 per 100 women-years. The locally released hormone leads to endometrial concentrations that are 200–800 times those found after daily oral use and a plasma level that is lower than that with other forms of levonorgestrel-containing contraception. The contraceptive effect of the LNG IUS is achieved mainly through its local suppressive effect on the endometrium, leading to endometrial thinning, glandular atrophy, and stromal decidualization without affecting ovulation. The LNG IUS is generally well tolerated. The main side effects are related to its androgenic activity, which is usually mild and transient, resolving after the first few months. Menstrual abnormalities are also common but well tolerated, and even become desirable (eg, amenorrhea, hypomenorrhea, and oligomenorrhea with proper counseling of the patient during the choice of the method of contraception. The satisfaction rates after 3 years of insertion are high, reaching between 77% and 94%. The local effect of the LNG IUS on the endometrium and low rates of systemic adverse effects have led to its use in other conditions rather than contraception, as for the treatment of endometrial hyperplasia, benign menorrhagia, endometriosis, adenomyosis, and uterine fibroids.Keywords: levonorgestrel, intrauterine device, contraception, family planning, Mirena, Skyla

  7. Neonatal cardiovascular system adaptation in babies with intrauterine growth retardation

    Directory of Open Access Journals (Sweden)

    I. N. Petrova

    2016-01-01

    Full Text Available Objective: to reveal the adaptive features of the cardiovascular system in newborn infants with intrauterine growth retardation (IUGR on the basis of a clinical instrumental study.Subjects and methods. A study group included 100 newborn infants with IUGR; a control group consisted of 40 babies with normal anthropometric measurements at birth. Medical history and clinical data and electrocardiographic and echocardiographic findings were analyzed.Results. All the examinees with IUGR had manifestations of cardiovascular system dysadaptation. There was a high rate of electrocardiographic changes, such as cardiac arrhythmias; low voltage; systolic overload of the right heart and left ventricle; signs of ventricular hypertrophy; and transient myocardial ischemia. The specific features of cardiac hemodynamics were decreased sizes of the left ventricle, lower parameters of its systolic function, and longer functioning of fetal communications.Conclusion. IUGR is associated with the development of cardiovascular system dysadaptation syndrome, which is due to prior perinatal hypoxia. The findings necessitate a follow-up of children by involving a cardiologist.

  8. Intrauterine Devices

    Science.gov (United States)

    S HARE W ITH W OMEN INTRAUTERINE DEVICES INTRAUTERINE DEVICES What is An Intrauterine Device? An intrauterine device (IUD) is anything that is placed inside the uterus (womb) to prevent pregnancy. ...

  9. The Effect of Age, Parity and Body Mass Index on the Efficacy, Safety, Placement and User Satisfaction Associated With Two Low-Dose Levonorgestrel Intrauterine Contraceptive Systems: Subgroup Analyses of Data From a Phase III Trial.

    Directory of Open Access Journals (Sweden)

    Kristina Gemzell-Danielsson

    Full Text Available Two low-dose levonorgestrel intrauterine contraceptive systems (LNG-IUSs; total content 13.5 mg [average approx. 8 μg/24 hours over the first year; LNG-IUS 8] and total content 19.5 mg [average approx. 13 μg/24 hours over the first year; LNG-IUS 13] have previously been shown to be highly effective (3-year Pearl Indices: 0.33 and 0.31, respectively, safe and well tolerated. The present subgroup analyses evaluated whether or not outcomes were affected by parity, age (18-25 vs 26-35 years, or body mass index (BMI, <30 vs ≥30 kg/m2.Nulliparous and parous women aged 18‒35 years with regular menstrual cycles (21‒35 days requesting contraception were randomized to 3 years of LNG-IUS 8 or LNG-IUS 13 use.In the LNG-IUS 8 and LNG-IUS 13 groups, 1432 and 1452 women, respectively, had a placement attempted and were included in the full analysis set; 39.2%, 39.2% and 17.1% were 18-25 years old, nulliparous and had a BMI ≥30 kg/m2, respectively. Both systems were similarly effective regardless of age, parity or BMI; the subgroup Pearl Indices had widely overlapping 95% confidence intervals. Placement of LNG-IUS 8 and LNG-IUS 13 was easier (p < 0.0001 and less painful (p < 0.0001 in women who had delivered vaginally than in women who had not. The complete/partial expulsion rate was 2.2-4.2% across all age and parity subgroups and higher in parous than in nulliparous women (p = 0.004. The incidence of pelvic inflammatory disease was 0.1-0.6% across all age and parity subgroups: nulliparous and younger women were not at higher risk than parous and older women, respectively. The ectopic pregnancy rate was 0.3-0.4% across all age and parity subgroups. Across all age and parity subgroups, the 3-year completion rate was 50.9-61.3% for LNG-IUS 8 and 57.9-61.1% for LNG-IUS 13, and was higher (p = 0.0001 among older than younger women in the LNG-IUS 8 group only.LNG-IUS 8 and LNG-IUS 13 were highly effective, safe and well tolerated regardless of age or

  10. Safety Systems

    Science.gov (United States)

    Halligan, Tom

    2009-01-01

    Colleges across the country are rising to the task by implementing safety programs, response strategies, and technologies intended to create a secure environment for teachers and students. Whether it is preparing and responding to a natural disaster, health emergency, or act of violence, more schools are making campus safety a top priority. At…

  11. Progesterone or progestogen-releasing intrauterine systems for heavy menstrual bleeding.

    Science.gov (United States)

    Lethaby, Anne; Hussain, Munawar; Rishworth, Josephine R; Rees, Margaret C

    2015-04-30

    Heavy menstrual bleeding (HMB) is an important cause of ill health in women and it accounts for 12% of all gynaecology referrals in the UK. Heavy menstrual bleeding is clinically defined as greater than or equal to 80 mL of blood loss per menstrual cycle. However, women may complain of excessive bleeding when their blood loss is less than 80 mL. Hysterectomy is often used to treat women with this complaint but medical therapy may be a successful alternative.The intrauterine device was originally developed as a contraceptive but the addition of progestogens to these devices resulted in a large reduction in menstrual blood loss. Case studies of two types of progesterone or progestogen-releasing systems, Progestasert and Mirena, reported reductions of up to 90% and improvements in dysmenorrhoea (pain or cramps during menstruation). Insertion, however, may be regarded as invasive by some women, which affects its acceptability as a treatment. Frequent intermenstrual bleeding and spotting is also likely during the first few months after commencing treatment. To determine the effectiveness, acceptability and safety of progesterone or progestogen-releasing intrauterine devices in achieving a reduction in heavy menstrual bleeding. All randomised controlled trials of progesterone or progestogen-releasing intrauterine devices for the treatment of heavy menstrual bleeding were obtained by electronic searches of The Cochrane Library, the specialised register of MDSG, MEDLINE (1966 to January 2015), EMBASE (1980 to January 2015), CINAHL (inception to December 2014) and PsycINFO (inception to January 2015). Additional searches were undertaken for grey literature and for unpublished trials in trial registers. Companies producing progestogen-releasing intrauterine devices and experts in the field were contacted for information on published and unpublished trials. Randomised controlled trials in women of reproductive age treated with progesterone or progestogen

  12. Intrauterine Morcellator Devices: The Icon of Hysteroscopic Future or Merely a Marketing Image? A Systematic Review Regarding Safety, Efficacy, Advantages, and Contraindications.

    Science.gov (United States)

    Noventa, Marco; Ancona, Emanuele; Quaranta, Michela; Vitagliano, Amerigo; Cosmi, Erich; D'Antona, Donato; Gizzo, Salvatore

    2015-10-01

    The aim of this study was to analyze all available evidence regarding the use of intrauterine morcellator (IUM), for treatment of the most prevalent intrauterine benign lesions, compared to both traditional resectoscopy and conventional outpatient operative hysteroscopy in terms of safety, efficacy, contraindications, perioperative complications, operating time, and estimated learning curve. We reported data regarding a total of 1185 patients. Concerning polypectomy and myomectomy procedures, IUM systems demonstrated a better outcome in terms of operative time and fluid deficit compared to standard surgical procedures. Complication rates in the inpatient setting were as follows: 0.02% for IUM using Truclear 8.0 (Smith & Nephew Endoscopy, Andover, Massachusetts) and 0.4% for resectoscopic hysteroscopy. No complications were described using Versapoint devices. Office polipectomy reported a total complication rate of 10.1% using Versapoint device (Ethicon Women's Health and Urology, Somerville, New Jersey) and 1.6% using Truclear 5.0 (Smith & Nephew Endoscopy). The reported recurrence rate after polypectomy was 9.8% using Versapoint device and 2.6% using Truclear 8.0. Finally, the reported intraoperative and postoperative complication rate of IUM related to removal of placental remnants using Truclear 8.0 and MyoSure (Hologic, Marlborough, Massachusetts) was 12.3%. The available evidence allows us to consider IUM devices as a safe, effective, and cost-effective tool for the removal of intrauterine lesions such as polyps, myomas (type 0 and type 1), and placental remnants. Evidence regarding Truclear 5.0 suggests that it may represent the best choice for office hysteroscopy. Further studies are needed to confirm the available evidence and to validate the long-term safety of IUM in procedures for which current data are not exhaustive (placental remnants removal). © The Author(s) 2015.

  13. Timing of insertion of levonorgestrel-releasing intrauterine system : a randomised controlled trial

    NARCIS (Netherlands)

    van der Heijden, Pahh; Geomini, Pmaj; Herman, M C; Veersema, S; Bongers, M Y

    OBJECTIVE: The objective was to assess whether patient-perceived pain during the insertion of the levonorgestrel-releasing intrauterine system (LNG-IUS) depends on the timing during the menstrual cycle. DESIGN: A stratified two-armed non-inferiority randomised controlled trial. SETTING: Large

  14. Simultaneous use of a levonorgestrel intrauterine system and an etonogestrel subdermal implant for debilitating adolescent endometriosis.

    Science.gov (United States)

    Al-Jefout, Moamar; Palmer, John; Fraser, Ian S

    2007-06-01

    Adolescent familial endometriosis may cause severe and persistent symptoms that are disruptive to lifestyle. Treatment may be difficult in many cases. We describe the novel and successful first use of a simultaneous combination of a levonorgestrel intrauterine system and an etonogestrel subdermal implant in a teenager with severe pain symptoms as a result of laparoscopically confirmed endometriosis, which was refractory to other treatments.

  15. A levonorgestrel-releasing intrauterine system embedded in the omentum in a woman with abdominal pain: a case report

    Directory of Open Access Journals (Sweden)

    Phillips Kevin

    2009-11-01

    Full Text Available Abstract Introduction The Mirena intrauterine system has been licensed as a contraceptive in the United Kingdom since May 1995. The use of an intrauterine system as a primary method of contraception among women has been slowly increasing over the last few years and they now account for about 3% of contraceptive use in England. The Mirena intrauterine system now also has a license for the management of idiopathic menorrhagia. Women may be informed that the rate of uterine perforation associated with intrauterine contraceptive use is low (0-2.3 per 1000 insertions. The rate of perforation reported with the Mirena intrauterine system in a large observational cohort study was 0.9 per 1000 insertions. Case presentation In this case report, the diagnosis of an intraperitoneal Mirena intrauterine system was noted nearly four years after its insertion, despite the patient having had a vaginal hysterectomy and admissions to hospital in the interim with complaints of abdominal pain. Conclusion This case report demonstrates clearly that whenever there is a question of a intrauterine system having fallen out following an ultrasound scan report showing an empty uterus, clinicians should also perform an abdominal X-ray.

  16. Intrauterine devices.

    Science.gov (United States)

    Bilian, Xiao

    2002-04-01

    The aim of this chapter is to review the worldwide use of intrauterine devices (IUDs) for contraception and the long-term contraceptive efficacy and safety of copper-bearing IUDs. The TCu380A and Multiload Cu375 have a very low failure rate (0.2-0.5%) over 10 years. The main concerns of the use of IUDs are risk of pelvic inflammatory diseases and increased menstrual blood loss and irregular bleeding. Factors associated with an increase in risk of pelvic inflammatory diseases are discussed. Preventive measures can be taken with careful screening of eligible IUD users, technical training and adequate service facilities for provision of IUDs. Levonorgestrel-releasing IUDs have the benefit of reducing menstrual blood loss in addition to high contraceptive efficacy. The copper IUD is the most effective method for emergency contraception. It can prevent over 95% of unwanted pregnancies within 5 days of unprotected intercourse. Copyright 2002 Elsevier Science Ltd.

  17. System safety education focused on flight safety

    Science.gov (United States)

    Holt, E.

    1971-01-01

    The measures necessary for achieving higher levels of system safety are analyzed with an eye toward maintaining the combat capability of the Air Force. Several education courses were provided for personnel involved in safety management. Data include: (1) Flight Safety Officer Course, (2) Advanced Safety Program Management, (3) Fundamentals of System Safety, and (4) Quantitative Methods of Safety Analysis.

  18. Levonorgestrel intrauterine system for endometrial protection in women with breast cancer on adjuvant tamoxifen.

    Science.gov (United States)

    Dominick, Sally; Hickey, Martha; Chin, Jason; Su, H Irene

    2015-12-09

    Adjuvant tamoxifen reduces the risk of breast cancer recurrence in women with oestrogen receptor-positive breast cancer. Tamoxifen also increases the risk of postmenopausal bleeding, endometrial polyps, hyperplasia, and endometrial cancer. The levonorgestrel-releasing intrauterine system (LNG-IUS) causes profound endometrial suppression. This systematic review considered the evidence that the LNG-IUS prevents the development of endometrial pathology in women taking tamoxifen as adjuvant endocrine therapy for breast cancer. To determine the effectiveness and safety of levonorgestrel intrauterine system (LNG-IUS) in pre- and postmenopausal women taking adjuvant tamoxifen following breast cancer for the outcomes of endometrial and uterine pathology including abnormal vaginal bleeding or spotting, and secondary breast cancer events. We searched the following databases: Cochrane Menstrual Disorders and Subfertility Group Specialised Register (MDSG), Cochrane Breast Cancer Group Specialised Register (CBCG), Cochrane Central Register of Controlled Trials (CENTRAL), Cochrane Database of Abstracts of Reviews of Effects (DARE), The Cochrane Library, clinicaltrials.gov, The World Health Organisation International Trials Registry, ProQuest Dissertations & Theses, MEDLINE, EMBASE, CINAHL (Cumulative Index to Nursing and Allied Health Literature), PsycINFO, Web of Science, OpenGrey, LILACS, PubMed, and Google. The final search was performed in October 2015. Randomised controlled trials of women with breast cancer on adjuvant tamoxifen that compared endometrial surveillance alone (control condition) versus the LNG-IUS with endometrial surveillance (experimental condition) on the incidence of endometrial pathology. Study selection, risk of bias assessment and data extraction were performed independently by two review authors. The primary outcome measure was endometrial pathology (including polyps, endometrial hyperplasia, or endometrial cancer) diagnosed at hysteroscopy or

  19. Features of the cardiovascular system in babies born with different types of intrauterine growth restriction

    Directory of Open Access Journals (Sweden)

    L. V. Kozlova

    2017-01-01

    Full Text Available Based on the data of clinical and anamnestic examination, cardiointervalography, electrocardiography, and Doppler echocardiography, the investigators examined the features of the cardiovascular system in children born by women with compromised somatic and gynecological histories in the outcome of complicated pregnancy. Groups 1 and 2 included 72 and 69 infants with and without fetal growth restriction, respectively. Group 1 comprised Subgroup 1a of 57 infants with asymmetrical intrauterine growth restriction and Subgroup 1b of 15 children with symmetrical one; of them there were 13 and 2 infants with hypoplastic and dysplastic types. Apparently healthy infants born by apparently healthy mothers in the outcome of physiological pregnancies made up Group 3 (n = 25.There is proof that there are significantly important features of autonomic regulation of cardiac activity and morphofunctional characteristics of the heart. The infants with symmetrical intrauterine growth retardation, unlike those with asymmetrical one, were observed to have impaired autonomic regulation of cardiac activity, which was less obvious at birth, deteriorating over time. At birth, the babies had morphological features of the heart and a greater frequency of functioning of fetal communications. Impaired myocardial metabolic processes prevailed within the first month of life and there was a large frequency of changes similar to those in hypertrophic cardiomyopathy by the end of the first half of life.The featuresrevealed in the infants with different types of intrauterine growth restriction require electrocardiographic and ultrasound examinations, a pediatric cardiologist’s consultations at a maternity hospital, and a subsequent personalized follow-up with corrective measures at an outpatient setting. 

  20. Safety system function trends

    International Nuclear Information System (INIS)

    Johnson, C.

    1989-01-01

    This paper describes research to develop risk-based indicators of plant safety performance. One measure of the safety-performance of operating nuclear power plants is the unavailability of important safety systems. Brookhaven National Laboratory and Science Applications International Corporation are evaluating ways to aggregate train-level or component-level data to provide such an indicator. This type of indicator would respond to changes in plant safety margins faster than the currently used indicator of safety system unavailability (i.e., safety system failures reported in licensee event reports). Trends in the proposed indicator would be one indication of trends in plant safety performance and maintenance effectiveness. This paper summarizes the basis for such an indicator, identifies technical issues to be resolved, and illustrates the potential usefullness of such indicators by means of computer simulations and case studies

  1. Safety of hormonal contraception and intrauterine devices among women with depressive and bipolar disorders: a systematic review.

    Science.gov (United States)

    Pagano, H Pamela; Zapata, Lauren B; Berry-Bibee, Erin N; Nanda, Kavita; Curtis, Kathryn M

    2016-12-01

    Women with depressive or bipolar disorders are at an increased risk for unintended pregnancy. To examine the safety of hormonal contraception among women with depressive and bipolar disorders. We searched for articles published through January 2016 on the safety of using any hormonal contraceptive method among women with depressive or bipolar disorders, including those who had been diagnosed clinically or scored above threshold levels on a validated screening instrument. Outcomes included changes in symptoms, hospitalization, suicide and modifications in medication regimens such as increase or decrease in dosage or changes in type of drug. Of 2376 articles, 6 met the inclusion criteria. Of three studies that examined women clinically diagnosed with depressive or bipolar disorder, one found that oral contraceptives (OCs) did not significantly change mood across the menstrual cycle among women with bipolar disorder, whereas mood did significantly change across the menstrual cycle among women not using OCs; one found no significant differences in the frequency of psychiatric hospitalizations among women with bipolar disorder who used depot medroxyprogesterone acetate (DMPA), intrauterine devices (IUDs) or sterilization; and one found no increase in depression scale scores among women with depression using and not using OCs, for both those treated with fluoxetine and those receiving placebo. Of three studies that examined women who met a threshold for depression on a screening instrument, one found that adolescent girls using combined OCs (COCs) had significantly improved depression scores after 3 months compared with placebo, one found that OC users had similar odds of no longer being depressed at follow-up compared with nonusers, and one found that COC users were less frequently classified as depressed over 11 months than IUD users. Limited evidence from six studies found that OC, levonorgestrel-releasing IUD and DMPA use among women with depressive or bipolar

  2. The safety of intrauterine devices among young women: a systematic review.

    Science.gov (United States)

    Jatlaoui, Tara C; Riley, Halley E M; Curtis, Kathryn M

    2017-01-01

    The objective was to determine the association between use of intrauterine devices (IUDs) by young women and risk of adverse outcomes. We searched Pubmed, CINAHL, Embase, Popline and the Cochrane Library for articles from inception of database through December 2015. For outcomes specific to IUD use (IUD expulsion and perforation), we examined effect measures for IUD users generally aged 25 years or younger compared with older IUD users. For outcomes of pregnancy, infection, pelvic inflammatory disease (PID), and heavy bleeding or anemia, we examined young IUD users compared with young users of other contraceptive methods or no method. We identified 3169 articles of which 16 articles from 14 studies met our inclusion criteria. Six studies (Level II-2, good to poor) reported increased risk of expulsion among younger age groups compared with older age groups using copper-bearing (Cu-) IUDs. Two studies (Level II-2, fair) examined risks of expulsion among younger compared with older women using levonorgestrel-releasing (LNG-) IUDs; one reported no difference in expulsion, while the other reported increased odds for younger women. Four studies (Level II-2, good to poor) examined risk of expulsion among Cu- and LNG-IUD users combined and reported no significant differences between younger and older women. For perforation, four studies (Level II-2, fair to poor) found very low perforation rates (range, 0%-0.1%), with no significant differences between younger and older women. Pregnancies were generally rare among young IUD users in nine studies (Level I to II-2, fair to poor), and no differences were reported for young IUD users compared with young combined oral contraceptive (COC) or etonogestrel (ENG) implant users. PID was rare among young IUD users; one study reported no cases among COC or IUD users, and one reported no difference in PID among LNG-IUD users compared with ENG implant users from nationwide insurance claims data (Level I to II-2, fair). One study

  3. Levonorgestrel releasing intrauterine system (Mirena) versus endometrial ablation (Novasure) in women with heavy menstrual bleeding: a multicentre randomised controlled trial

    NARCIS (Netherlands)

    Herman, Malou C.; van den Brink, Marian J.; Geomini, Peggy M.; van Meurs, Hannah S.; Huirne, Judith A.; Eising, Heleen P.; Timmermans, Anne; Pijnenborg, Johanna M. A.; Klinkert, Ellen R.; Coppus, Sjors F.; Nieboer, Theodoor E.; Catshoek, Ruby; van der Voet, Lucet F.; van Eijndhoven, Hugo W. F.; Graziosi, Giuseppe C. M.; Veersema, Sebastiaan; van Kesteren, Paul J.; Langenveld, Josje; Smeets, Nicol A. C.; van Vliet, Huib A. A. M.; van der Steeg, Jan Willem; Lisman-van Leeuwen, Yvonne; Dekker, Janny H.; Mol, Ben W.; Berger, Marjolein Y.; Bongers, Marlies Y.

    2013-01-01

    Heavy menstrual bleeding is an important health problem. Two frequently used therapies are the levonorgestrel intra-uterine system (LNG-IUS) and endometrial ablation. The LNG-IUS can be applied easily by the general practitioner, which saves costs, but has considerable failure rates. As an

  4. Levonorgestrel releasing intrauterine system (Mirena) versus endometrial ablation (Novasure) in women with heavy menstrual bleeding : a multicentre randomised controlled trial

    NARCIS (Netherlands)

    Herman, Malou C.; van den Brink, Marian; Geomini, Peggy M.; van Meurs, Hannah S.; Huirne, Judith A.; Eising, Heleen P.; Timmermans, Anne; Pijnenborg, Johanna M. A.; Klinkert, Ellen R.; Coppus, Sjors F.; Nieboer, Theodoor E.; Catshoek, Ruby; van der Voet, Lucet F.; van Eijndhoven, Hugo W. F.; Graziosi, Giuseppe C. M.; Veersema, Sebastiaan; van Kesteren, Paul J.; Langenveld, Josje; Smeets, Nicol A. C.; van Vliet, Huib A. A. M.; van der Steeg, Jan Willem; Lisman-van Leeuwen, Yvonne; Dekker, Janny H.; Mol, Ben W.; Berger, Marjolein Y.; Bongers, Marlies Y.

    2013-01-01

    Background: Heavy menstrual bleeding is an important health problem. Two frequently used therapies are the levonorgestrel intra-uterine system (LNG-IUS) and endometrial ablation. The LNG-IUS can be applied easily by the general practitioner, which saves costs, but has considerable failure rates. As

  5. Patient satisfaction for levonorgestrel intrauterine system and norethisterone for treatment of dysfunctional uterine bleeding

    International Nuclear Information System (INIS)

    Naqaish, T.; Rizvi, F.; Khan, A.; Afzal, M.

    2012-01-01

    Background: Dysfunctional uterine bleeding (DUB) is a common problem with complex management. It can be quite harrowing for the physicians as in most instances they are unable to pinpoint the cause of abnormal bleeding even after a thorough history and physical examination. Aim was to compare patient satisfaction for Levonorgestrel intra uterine system (LNG-IUS) and Norethisterone for the treatment of Dysfunctional Uterine Bleeding (DUB). It is Descriptive case series conducted in Department Obstetrics and Gynaecology, Shifa International Hospital, Islamabad from September, 2011 to September, 2012. Methods: One hundred and nineteen (119) female patients of reproductive age Group with DUB were selected by consecutive sampling. Informed written consent was obtained. A structural patient satisfaction questionnaire (PSQ) was used to collect information regarding age of patients, type of method used for treatment of DUB (Levonorgestrel or Norethisterone), treatment outcome in terms of patient satisfaction scale, and decrease in bleeding after 6 months. Results: The mean age of the patients was 41.03+-4.415 year ranging from 28-60 years. The mean parity of women in the study was 3.22+-1.188 with a range of 1-7. The satisfaction level was significantly (p<0.05) greater (90% versus 20%) in Group A (levonorgesterol-releasing intrauterine system) as compared with Group B (Norethisterone). The blood loss was significantly (p<0.05) decreased in Group A (98%) as compared with Group B (80%). The preference of continuing the method as well as recommendation to a friend was significantly greater in Group A as compared to Group B. Conclusion: The levonorgesterol-releasing intrauterine system (LNG-IUS) is a better choice as compared to Norethisterone, for treatment of DUB with 90% patients highly satisfied. (author)

  6. Evaluating the Efficacy of Levonorgestrel Intrauterine System and Danazol for Relief of Postoperative Pain in Endometriosis.

    Science.gov (United States)

    Taneja, Ashima; Kaur, Satinder; Soni, R K; Bhanupriya; Kaur, Jaspreet; Singla, Laveen

    2017-07-01

    Endometriosis is an oestrogen-dependent disorder, manifests during reproductive years and is associated with pain and infertility. There is considerable debate about the effectiveness of various interventions for pain relief. To evaluate the efficacy of Levonorgestrel Intrauterine System (LNG-IUS) and Danazol in postoperative pain relief for patients with endometriosis. Hundred patients with diagnosis of endometriosis, who were treated laparoscopically, entered the study to receive either danazol (600 mg once daily) or LNG-IUS (inserted during immediate post operative period) postsurgery, for pain relief. Patients were analysed for pain relief according to VAS score and recurrence of disease using ultrasonography at third and sixth months of follow up. There were 50% patients in stage IV of endometriosis. Majority of them presented with complaint of infertility (49%) and pelvic pain (43%). It was observed that LNG-IUS was significantly more effective in relieving pain compared to danazol (65.2% vs 38.0%, ppain compared to danazol.

  7. Comparison of two cohorts of women who expulsed either a copper-intrauterine device or a levonorgestrel-releasing intrauterine system.

    Science.gov (United States)

    Simonatto, Paula; Bahamondes, Maria Valeria; Fernandes, Arlete; Silveira, Carolina; Bahamondes, Luis

    2016-05-01

    To assess if there is a difference in the characteristics of the women who expelled a copper-intrauterine device (TCu-IUD) or the levonorgestrel-releasing intrauterine system (LNG-IUS) and the frequency of expulsions over different periods of observation. We retrospectively analyzed 19 697 medical charts of women consulting between January 1980 and December 2013 who requested a TCu-IUD or a LNG-IUS. The medical records of 17 644 Cu-IUD and 2053 LNG-IUS users returning to the clinic for a follow-up visit after insertion of an IUC were reviewed. Of these, 1532 Cu-IUD and 254 LNG-IUS parous users were found to have expelled the IUC for a first time. The mean age at insertion (± standard deviation) was 26.3 ± 6.6 years (range 16-49) for Cu-IUD users and 31.7 ± 7.6 years (range 18-48) for LNG-IUS users (P < 0.001). A total of 263 (13.4%) and 12 (4.3%) of the Cu-IUD and the LNG-IUS users were ≤19 years old, and 49.1% and 54.1% of the expulsions among the Cu-IUD and LNG-IUS users, respectively, were reported in the first six months after placement. A regression model showed that the variables significantly associated with an expulsion of either a Cu-IUD or LNG-IUS were age < 25 years, less than two deliveries and using a Cu-IUD. Our findings showed that the characteristics associated with IUC expulsion were age under 25 years, having had less than two deliveries and being users of Cu-IUD. © 2016 Japan Society of Obstetrics and Gynecology.

  8. Weight variation in users of depot-medroxyprogesterone acetate, the levonorgestrel-releasing intrauterine system and a copper intrauterine device for up to ten years of use.

    Science.gov (United States)

    Modesto, Waleska; de Nazaré Silva dos Santos, Priscila; Correia, Vinicius Machado; Borges, Luiza; Bahamondes, Luis

    2015-02-01

    Data on record regarding weight variation in depot-medroxyprogesterone acetate (DMPA) and levonorgestrel-releasing intrauterine system (LNG-IUS) users are controversial. To date, no studies have yet evaluated weight variation in DMPA and LNG-IUS users in up to ten years of use compared to non-hormonal contraceptive users. A retrospective study analysed weight variations in 2138 women using uninterruptedly DMPA (150 mg intramuscularly, three-monthly; n = 714), the LNG-IUS (n = 701) or a copper-intrauterine device (Cu-IUD; n = 723). At the end of the first year of use, there was a mean weight increase of 1.3 kg, 0.7 kg and 0.2 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively, compared to weight at baseline (p < 0.0001). After ten years of use, the mean weight had risen by 6.6 kg, 4.0 and 4.9 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively. DMPA-users had gained more weight than LNG-IUS- (p = 0.0197) and than Cu-IUD users (p = 0.0294), with the latter two groups not differing significantly from each other in this respect (p = 0.5532). Users of hormonal and non-hormonal contraceptive methods gained a significant amount of weight over the years. DMPA users gained more weight over the treatment period of up to ten years than women fitted with either a LNG-IUS or a Cu-IUD.

  9. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  10. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  11. Software system safety

    Science.gov (United States)

    Uber, James G.

    1988-01-01

    Software itself is not hazardous, but since software and hardware share common interfaces there is an opportunity for software to create hazards. Further, these software systems are complex, and proven methods for the design, analysis, and measurement of software safety are not yet available. Some past software failures, future NASA software trends, software engineering methods, and tools and techniques for various software safety analyses are reviewed. Recommendations to NASA are made based on this review.

  12. Reactor safety assessment system

    International Nuclear Information System (INIS)

    Sebo, D.E.; Bray, M.A.; King, M.A.

    1987-01-01

    The Reactor Safety Assessment System (RSAS) is an expert system under development for the United States Nuclear Regulatory Commission (USNRC). RSA is designed for use at the USNRC Operations Center in the event of a serious incident at a licensed nuclear power plant. RSAS is a situation assessment expert system which uses plant parametric data to generate conclusions for use by the NRC Reactor Safety Team. RSAS uses multiple rule bases and plant specific setpoint files to be applicable to all licensed nuclear power plants in the United States. RSAS currently covers several generic reactor categories and multiple plants within each category

  13. LEVONORGESTREL-RELEASING INTRAUTERINE SYSTEM AS AN ALTERNATIVE THERAPY IN ABNORMAL UTERINE BLEEDING

    Directory of Open Access Journals (Sweden)

    Kunjamma Roy

    2017-05-01

    Full Text Available BACKGROUND Abnormal uterine bleeding is one of the most frequent reasons for gynaecological consultation, occurring in approximately 30% of women of reproductive age. Menorrhagia by definition implies a menstrual blood loss equal to or greater than 80 mL. Many women seek consultation for bleeding episodes of less than this amount because of the stress associated with it. Most frequently used medications are combinations of prostaglandin synthetase inhibitors and antifibrinolytic drugs, nonsteroidal antiinflammatory drugs, oral progesterone like Norethisterone or medroxyprogesterone acetate and combined oral contraceptives. The usual treatment for women with menorrhagia not desiring further pregnancies and those not responding to medical managements is either hysterectomy or endometrial ablation. Endometrial ablation less commonly performed due to low success rate. Levonorgestrel intrauterine system (LNG-IUS is a new modality in the treatment of AUB. The objective of this study is to evaluate the use of Levonorgestrel intrauterine system as a treatment for women with menorrhagia. MATERIALS AND METHODS This is a prospective interventional comparative study conducted on women with abnormal uterine bleeding. The duration of study was from March 2012 to October 2013. The respondents include those outpatients attending Gynaecology Department of Government Medical College, Kottayam with menorrhagia. The samples size was 50 of which 25 were in experimental groups and remaining 25 in control group. Experimental group were given LNG IUS for menorrhagia and the remaining 25 patients were given oral progestins for heavy menstrual bleeding. In order to make a comparison of the impact of the two different kinds of interventions, the Hb level as well as the amount of blood loss were systematically estimated at frequent intervals. Accordingly, these measurements were carried for the said both groups at the commencement of research study and thereafter at an

  14. Systems Safety and Engineering Division

    Data.gov (United States)

    Federal Laboratory Consortium — Volpe's Systems Safety and Engineering Division conducts engineering, research, and analysis to improve transportation safety, capacity, and resiliency. We provide...

  15. A model and scoring system to predict outcome of intrauterine pregnancies of uncertain viability.

    Science.gov (United States)

    Bottomley, C; Van Belle, V; Pexsters, A; Papageorghiou, A T; Mukri, F; Kirk, E; Van Huffel, S; Timmerman, D; Bourne, T

    2011-05-01

    To define the incidence and outcome of intrauterine pregnancy of uncertain viability (PUV) and to develop and assess the performance of a model and a scoring system to predict ongoing viability. Of 1881 consecutive women undergoing transvaginal ultrasonography, a cohort of 493 women with an empty gestational sac model and a 'simple' model in the prediction of viability at each outcome point, based on maternal demographics, ultrasound features and symptoms. The performance of each system was assessed by receiver-operating characteristics (ROC) curve analysis and calibration plots on a test dataset. The incidence of PUV in this population was 29.2% (549/1881). Of the 493 pregnancies with initial (7-14 days) follow-up available, 307 (62.3%) were viable at this time and of the 444 pregnancies with follow-up at the end of the first trimester, 225 (50.7%) were still viable. Initial (7-14-day) viability was predicted by the model with an area under the ROC curve (AUC) of 0.837 (95% CI, 0.791-0.884) in the training dataset and 0.821 (95% CI, 0.756-0.885) in the test dataset. First-trimester (11-14-week) viability was predicted by the model with an AUC of 0.788 (95% CI, 0.734-0.842) in the training dataset and 0.774 (95% CI, 0.701-0.848) in the test dataset. The scoring system performed slightly worse than did the model, but had the advantage of being easily applicable. When early pregnancy viability cannot be established immediately with ultrasound, use of either a logistic regression model or a scoring system allows an individualized prediction of first-trimester outcome. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  16. Progesterone/progestogen releasing intrauterine systems versus either placebo or any other medication for heavy menstrual bleeding.

    Science.gov (United States)

    Lethaby, A E; Cooke, I; Rees, M

    2000-01-01

    Heavy menstrual bleeding (HMB) is an important cause of ill health in women and it accounts for 12% of all gynaecology referrals in the UK. Heavy menstrual bleeding is clinically defined as greater than, or equal to, 80mls blood loss per menstrual cycle but women may complain of excessive bleeding when their blood loss is less than 80ml. Hysterectomy is often used to treat women with this complaint but medical therapy may be a successful alternative. The intrauterine coil device was originally developed as a contraceptive but the addition of uterine relaxing hormones, or progestogens, to these devices resulted in a large reduction in menstrual blood loss. Case studies of 2 types of progesterone/progestogen releasing systems, Progestasert and Mirena, report reductions of up to 90% and dysmenorrhoea may be improved. Insertion, however, may be regarded as invasive by some women affecting its acceptability as a treatment and frequent intermenstrual bleeding and spotting is likely during the first few months. To determine the effectiveness and acceptability of progesterone/progestogen-releasing intrauterine devices in achieving a reduction in heavy menstrual bleeding. All studies which might describe randomised controlled trials of progesterone/progestagen-releasing intrauterine devices for the treatment of heavy menstrual bleeding were obtained by electronic searches of the MEDLINE 1966-1999, EMBASE 1980-1999 databases and the Cochrane Library. Companies producing progestogen releasing intrauterine devices and experts in the field were contacted for information on published and unpublished trials. Randomised controlled trials in women of reproductive age treated with progesterone/progestogen-releasing intrauterine devices versus no treatment, placebo, or other medical or surgical therapy for heavy menstrual bleeding within either the primary care, family planning or specialist clinic setting were eligible for inclusion. Women with postmenopausal bleeding

  17. Intrauterine contraception.

    Science.gov (United States)

    Soonawalla, R P

    1968-01-01

    This article is presented to give an idea as to how far the IUD can fulfill the purpose of population control. For the couple, this intrauterine method is most ideal. The main drawback is the side effect of bleeding, which is the cause of the high drop out rate. The other handicaps are spontaneous expulsion and pregnancy with the IUD in situ. It is also unsuited to nulliparous women. The general practitioner needs to become concerned with the gravity of the problem of overpopulation, and he must encourage his patients into the use of contraceptives. At the moment, the IUD is the method of choice.

  18. Menstrual suppression with the levonorgestrel intrauterine system in girls with developmental delay.

    Science.gov (United States)

    Hillard, Paula J Adams

    2012-10-01

    To describe the experiences of 21 girls with developmental delay accompanied by multiple other medical problems, seen over a 3-year interval, who underwent insertion of the levonorgestrel intrauterine system (LNG-IUS) for menstrual suppression. Retrospective chart review. A referral pediatric and adolescent gynecology clinic within a tertiary care medical center with referrals from community pediatricians, pediatric subspecialists including developmental and behavioral pediatricians, community gynecologists, and adolescent medicine specialists. Adolescents and young women with developmental delay and multiple comorbid conditions who were seen for consultation with their families requesting menstrual suppression. Participants were offered hormonal options, for menstrual suppression including the LNG-IUS. Satisfaction with menstrual suppression among families electing the LNG-IUS. Adolescents and young women seen at CCHMC with developmental delay and multiple comorbid conditions with requests for menstrual suppression were offered hormonal options, including the LNG-IUS. Twenty-one families chose this option. Fifteen of 21 girls had previously used hormonal menstrual suppression. General anesthesia was required for 20 of 21 insertions, and 9 of 20 of these insertions were combined with other surgical procedures. There were no unsuccessful insertions or major complications. Mean duration of follow-up was 11 months, and families were satisfied with this option for menstrual suppression. There was 1 request for removal. LNG-IUS for menstrual suppression, in girls with developmental delay and multiple comorbid medical conditions for which amenorrhea is desirable and therapeutic, appears promising. Copyright © 2012 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  19. Effect of Guizhifuling capsule combined with levonorgestrel releasing intrauterine system on adenomyosis

    Directory of Open Access Journals (Sweden)

    Dong-Tao Shi

    2016-11-01

    Full Text Available Objective: To explore the clinical efficacy of Guizhifuling capsule combined with levonorgestrel releasing intrauterine system (LNG-IUS in the treatment of adenomyosis (AM. Methods: A total of 80 patients with AM who were admitted in our hospital from February, 2015 to February, 2016 were included in the study and randomized into the study group and the control group. LNG-IUS was placed in patients in the two groups 7 d after menstruation. The patients in the study group were given additional Guizhifuling capsule, 3 capsules/time, 3 times/d, and the drug was withdrawn in the menstrual period. Six-month treatment was regarded as one course. PBAC was used to evaluate the menstrual blood volume before and after treatment. The chronic pain grading questionnaire method was used for dysmenorrhea degree rating. The vaginal B ultrasound 3 d after menstruation was performed to detect the uterine volume. E2, FSH, LH, and serum CA125 level before and after treatment were detected. Results: The menstrual blood volume, dysmenorrhea degree, and uterine volume after treatment in the two groups were significantly reduced when compared with before treatment (P0.05. After treatment, CA125 level in the two groups was significantly reduced when compared with before treatment (P<0.05, and the reduced degree in the study group was significantly superior to that in the control group (P<0.05. Conclusions: Guizhifuling capsule combined with LNG-IUS in the treatment of AM can significantly improve the clinical symptoms, effectively reduce CA125 level, and has no significant effect on the sex hormone levels with a satisfactory clinical efficacy; therefore, it deserves to be widely recommended in the clinic.

  20. A 12-month multicenter, randomized study comparing the levonorgestrel intrauterine system with the etonogestrel subdermal implant.

    Science.gov (United States)

    Apter, Dan; Briggs, Paula; Tuppurainen, Marjo; Grunert, Julia; Lukkari-Lax, Eeva; Rybowski, Sarah; Gemzell-Danielsson, Kristina

    2016-07-01

    To compare the levonorgestrel intrauterine system (LNG-IUS 8), which has an average levonorgestrel release rate of ∼8 μg/24 hours during the first year (total levonorgestrel content 13.5 mg; Jaydess/Skyla), with the etonogestrel (ENG) subdermal implant (total content, 68 mg) with regard to the 12-month discontinuation rate (primary outcome). Randomized, open-label, phase III study. Thirty-eight centers in six European countries. Study population of 766 healthy nulliparous and parous women aged 18-35 years. The LNG-IUS 8 or the ENG implant. Discontinuation rate, by treatment group, at Month 12. The 12-month discontinuation rates were 19.6% and 26.8% in the LNG-IUS 8 and ENG implant groups, respectively. The -7.2% difference was statistically significant (95% confidence interval -13.2%, -1.2%). Fewer women in the LNG-IUS 8 group than in the ENG implant group discontinued because of increased bleeding (3.2% vs. 11.3%) or adverse events (14.3% vs. 21.8%). At 12 months, more women in the LNG-IUS 8 group than in the ENG implant group were "very/somewhat satisfied" with their bleeding pattern (60.9% vs. 33.6%) and reported a preference to use their study treatment after study completion (70.1% vs. 58.5%). The LNG-IUS 8 was associated with a significantly lower 12-month discontinuation rate compared with the ENG implant; mainly because ENG implant users frequently discontinued due to increased bleeding. More LNG-IUS 8 users than ENG implant users reported being "very/somewhat satisfied" with their bleeding pattern, and reported a preference to continue using their study treatment after the study. NCT01397097. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Association of baseline bleeding pattern on amenorrhea with levonorgestrel intrauterine system use.

    Science.gov (United States)

    Mejia, Manuela; McNicholas, Colleen; Madden, Tessa; Peipert, Jeffrey F

    2016-11-01

    This study aims to evaluate the effect of baseline bleeding patterns on rates of amenorrhea reported at 12 months in levonorgestrel (LNG) 52 mg intrauterine system (IUS) users. We also assessed the effect of baseline bleeding patterns at 3 and 6 months postinsertion. In this secondary analysis of the Contraceptive CHOICE Project, we included participants who had an LNG-IUS inserted within 1 month of enrollment and continued use for 12 months. Using 12-month telephone survey data, we defined amenorrhea at 12 months of use as no bleeding or spotting during the previous 6 months. We used chi-square and multivariable logistic regression to assess the association of baseline bleeding pattern with amenorrhea while controlling for confounding variables. Of 1802 continuous 12-month LNG-IUS users, amenorrhea was reported by 4.9%, 14.8% and 15.4% of participants at 3, 6 and 12 months, receptively. Participants with light baseline bleeding or short duration of flow reported higher rates of amenorrhea at 3 and 6 months postinsertion (pamenorrhea at 3 and 6 months (pamenorrhea at 12 months than those who reported moderate bleeding (OR adj , 0.36; 95% CI, 0.16-0.69). Women with heavier menstrual bleeding are less likely than women with moderate flow to report amenorrhea following 12 months of LNG-IUS use. Baseline heavy menstrual flow reduces the likelihood of amenorrhea with LNG-IUS use, information that could impact contraceptive counseling. Anticipatory counseling can improve method satisfaction and continuation, an important strategy to continue to reduce unintended pregnancy and abortion rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Nuclear reactor safety systems

    International Nuclear Information System (INIS)

    Ball, R.M.; Roberts, R.C.

    1980-01-01

    A safety system for shutting down a nuclear reactor under overload conditions is described. The system includes a series of parallel-connected computer memory type look-up tables each of which receives data on a particular reactor parameter and in each of which a precalculated functional value for that parameter is stored indicative of the percentage of maximum reactor load that the parameter contributes. The various functional values corresponding to the actual measured parameters are added together to provide a control signal used to shut down the reactor under overload conditions. (U.K.)

  3. Nuclear reactor safety system

    International Nuclear Information System (INIS)

    Ball, R.M.; Roberts, R.C.

    1983-01-01

    The invention provides a safety system for a nuclear reactor which uses a parallel combination of computer type look-up tables each of which receives data on a particular parameter (from transducers located in the reactor system) and each of which produces the functional counterpart of that particular parameter. The various functional counterparts are then added together to form a control signal for shutting down the reactor. The functional counterparts are developed by analysis of experimental thermal and hydraulic data, which are used to form expressions that define safe conditions

  4. Uterine Length in Adolescents with Developmental Disability: Are Ultrasound Examinations Necessary before Insertion of the Levonorgestrel Intrauterine System?

    Science.gov (United States)

    Whyte, Helena; Pecchioli, Yael; Oyewumi, Lamide; Kives, Sari; Allen, Lisa M; Kirkham, Yolanda A

    2016-12-01

    (1) To determine if there are any differences in uterine length between adolescents with developmental disability (DD) compared with their normally developing (ND) peers that might necessitate ultrasonography before insertion of levonorgestrel intrauterine system (LNG-IUS) in patients with DD; and (2) to characterize the LNG-IUS insertion procedure in adolescents with disabilities. This was a retrospective cohort study of 223 female adolescents with or without DDs. Seventy-five adolescents had DD; 33 underwent intrauterine system insertion in the operating room and 42 did not. A comparative cohort of 148 ND adolescents who had pelvic ultrasound examinations for abnormal uterine bleeding were included. The study period was between January 2006 and July 2013 at the Hospital for Sick Children, Toronto, Canada. Cases were identified from surgical databases and medical records. Mean uterine length on pelvic ultrasound, demographic characteristics (age, age at menarche, time from menarche to ultrasound, weight), and descriptive statistics on intrauterine system insertion. There was a statistically significant difference (P = .03) in uterine length between adolescents with and without DD (6.7 vs 7.1 cm). However, this was not a clinically significant difference because insertion of the LNG-IUS in patients with DD was successful in patients with uteri more than 5 cm long. There was no difference (P = .97) in uterine length of adolescents with DD whether they had LNG-IUS insertion or not (6.7 cm). Adolescents with DD were younger than adolescents without DD at time of ultrasound examination (P = .01). However, among patients with DD, those who underwent intrauterine system insertion were older (P = .001). Incidence of uterine anomaly in patients with DD is low (2.7%) and was the same as in ND adolescents. Rates of complications and expulsions were low and there were no failures of LNG-IUS insertion in adolescents with DD. Routine pelvic ultrasound examinations

  5. Levonorgestrel-Releasing Intrauterine System (52 mg) for Idiopathic Heavy Menstrual Bleeding: A Health Technology Assessment.

    Science.gov (United States)

    2016-01-01

    Heavy menstrual bleeding affects as many as one in three women and has negative physical, economic, and psychosocial impacts including activity limitations and reduced quality of life. The goal of treatment is to make menstruation manageable, and options include medical therapy or surgery such as endometrial ablation or hysterectomy. This review examined the evidence of effectiveness and cost-effectiveness of the 52-mg levonorgestrel-releasing intrauterine system (LNG-IUS) as a treatment alternative for idiopathic heavy menstrual bleeding. We conducted a systematic review of the clinical and economic evidence comparing LNG-IUS with usual medical therapy, endometrial ablation, or hysterectomy. Medline, EMBASE, Cochrane, and the Centres for Reviews and Dissemination were searched from inception to August 2015. The quality of the evidence was assessed according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We also completed an economic evaluation to determine the cost-effectiveness and budget impact of the LNG-IUS compared with endometrial ablation and with hysterectomy. The economic evaluation was conducted from the perspective the Ontario Ministry of Health and Long-Term Care. Relevant systematic reviews (n = 18) returned from the literature search were used to identify eligible randomized controlled trials, and 16 trials were included. The LNG-IUS improved quality of life and reduced menstrual blood loss better than usual medical therapy. There was no evidence of a significant difference in these outcomes compared with the improvements offered by endometrial ablation or hysterectomy. Mild hormonal side effects were the most commonly reported. The quality of the evidence varied from very low to moderate across outcomes. Results from the economic evaluation showed the LNG-IUS was less costly (incremental saving of $372 per person) and more effective providing higher quality-adjusted life years (incremental

  6. Levonorgestrel-Releasing Intrauterine System for Women With Polycystic Ovary Syndrome: Metabolic and Clinical Effects.

    Science.gov (United States)

    da Silva, Adriana Valerio; de Melo, Anderson Sanches; Barboza, Rebecca Pontelo; de Paula Martins, Wellington; Ferriani, Rui Alberto; Vieira, Carolina Sales

    2016-07-01

    Polycystic ovary syndrome (PCOS) is related to clinical and metabolic comorbidities that may limit the prescription of combined hormonal contraceptives, with consequent need to use progestogen-only contraceptives (POCs). Thus, the objective of the present study was to evaluate the clinical and metabolic effects of a POC, the levonorgestrel-releasing intrauterine system (LNG-IUS), in women with PCOS followed up over a period of 6 months compared to baseline and to women without PCOS. Thus, an observational, prospective, controlled study was conducted on 30 women with a diagnosis of PCOS who presented adverse effect secondary to the use of combined oral contraceptives (nausea, headache, mastalgia or vomiting; PCOS group) paired with 30 ovulatory women without PCOS (control group), both groups being free of comorbidities and having chosen the LNG-IUS as contraceptive. Clinical, laboratory, and ultrasonographic variables were evaluated immediately before LNG-IUS insertion and 6 months after the use of this method. Before LNG-IUS insertion, the PCOS group had higher total testosterone levels (P = .04), lower HDL levels (P = .04), and greater ovarian volume (P < .01) than the control group. Six months after LNG-IUS insertion, there was a 2.3% increase in abdominal circumference (P = .04) and a 3.4% increase in fasting glycemia (P = .02). On the other hand, mean ovarian volume was 10% smaller compared to the volume found before LNG-IUS insertion (P = .04), LDL levels were reduced by 5.2% (P = .03), and total cholesterol levels were reduced by 6.7% (P < .01) compared to baseline evaluation in the PCOS group. The remaining variables did not differ significantly during the 6 months of observation. The control group did not show significant changes compared to the period before LNG-IUS insertion. When the groups were compared after the 6-month follow-up, only glycemia showed a statistically significant variation between the groups, with glycemia levels increasing by 3.4% in

  7. Safety significance evaluation system

    International Nuclear Information System (INIS)

    Lew, B.S.; Yee, D.; Brewer, W.K.; Quattro, P.J.; Kirby, K.D.

    1991-01-01

    This paper reports that the Pacific Gas and Electric Company (PG and E), in cooperation with ABZ, Incorporated and Science Applications International Corporation (SAIC), investigated the use of artificial intelligence-based programming techniques to assist utility personnel in regulatory compliance problems. The result of this investigation is that artificial intelligence-based programming techniques can successfully be applied to this problem. To demonstrate this, a general methodology was developed and several prototype systems based on this methodology were developed. The prototypes address U.S. Nuclear Regulatory Commission (NRC) event reportability requirements, technical specification compliance based on plant equipment status, and quality assurance assistance. This collection of prototype modules is named the safety significance evaluation system

  8. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  9. A randomized, multi-center, clinical trial to assess the efficacy and safety of alginate carboxymethylcellulose hyaluronic acid compared to carboxymethylcellulose hyaluronic acid to prevent postoperative intrauterine adhesion.

    Science.gov (United States)

    Kim, Tak; Ahn, Ki Hoon; Choi, Doo Seok; Hwang, Kyung Joo; Lee, Byoung Ick; Jung, Min Hyung; Kim, Jae Weon; Kim, Jong Hyuk; Cha, Sun Hee; Lee, Ki Hwan; Lee, Kyu Sup; Oh, Sung Tack; Cho, Chi Heum; Rhee, Jeong Ho

    2012-01-01

    To estimate the efficacy of alginate carboxymethylcellulose hyaluronic acid (ACH) gel to prevent intrauterine adhesions after hysteroscopic surgery in comparison with carboxymethylcellulose hyaluronic acid (CH) gel, which is known as an effective adhesion inhibitor. Randomized, multicenter, single-blind, clinical trial (Canadian Task Force classification I). Tertiary university hospital. One hundred eighty-seven patients with a surgically treatable intrauterine lesion (myomas, polyps, septa, intrauterine adhesion, dysfunctional uterine bleeding). Patients were randomized to 2 groups: hysteroscopic surgery plus intrauterine application of ACH or CH. The rate of adhesion formation and the adhesion severity score with type and extent were calculated 4 weeks after surgery. The ACH group had results that were comparable to the CH group in terms of the development of intrauterine adhesions at 4 weeks follow-up. The adhesion severities were not different between the 2 groups. In a subgroup without baseline intrauterine adhesion, the ACH group showed a lower intrauterine adhesion rate than the CH group (p = .016). ACH had a comparable efficacy to CH in terms of the adhesion rate and severity. In the case of no baseline intrauterine adhesion, intrauterine application of ACH after hysteroscopic surgery had a lower rate of intrauterine adhesion than application of CH. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  10. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    Science.gov (United States)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  11. Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study

    Directory of Open Access Journals (Sweden)

    Wildemeersch D

    2014-08-01

    Full Text Available Dirk Wildemeersch,1 Sohela Jandi,2 Ansgar Pett,2 Kilian Nolte,3 Thomas Hasskamp,4 Marc Vrijens5 1Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium; 2Gynecological Outpatient Clinic, Berlin, 3Gynecological Outpatient Clinic, Uetze, 4GynMünster, Münster, Germany; 5Gynecological Outpatient Clinic, Ghent, Belgium Background: The purpose of this study was to provide additional data on the experience with frameless copper and levonorgestrel (LNG intrauterine devices (IUDs in nulliparous and adolescent women. Methods: Nulliparous and adolescent women, 25 years of age or younger, using the frameless copper IUD or the frameless LNG-releasing intrauterine system (IUS, were selected from previous studies and a current multicenter post-marketing study with the frameless copper IUD. The small copper-releasing GyneFix® 200 IUD consists of four copper cylinders, each 5 mm long and only 2.2 mm wide. The frameless FibroPlant® LNG-IUS consists of a fibrous delivery system releasing the hormone levonorgestrel (LNG-IUS. The main features of these intrauterine contraceptives are that they are frameless, flexible, and anchored to the fundus of the uterus. Results: One hundred and fifty-four nulliparous and adolescent women participated in the combined study. One pregnancy occurred with the GyneFix 200 IUD after unnoticed early expulsion of the device (cumulative pregnancy rate 1.1 at one year. Two further expulsions were reported, one with the GyneFix 200 IUD and the other with the FibroPlant LNG-IUS. The cumulative expulsion rate at one year was 1.1 with the copper IUD and 2.2 with the LNG-IUS. The total discontinuation rate at one year was low (3.3 and 4.3 with the copper IUD and LNG-IUS, respectively and resulted in a high rate of continuation of use at one year (96.7 with the copper IUD and 95.7 with the LNG-IUS, respectively. Continuation rates for both frameless copper IUD and frameless LNG-IUS remained high at 3 years (>90%. There

  12. Intrauterine devices (IUD)

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007635.htm Intrauterine devices (IUD) To use the sharing features on this page, please enable JavaScript. An intrauterine device (IUD) is a small plastic T-shaped device ...

  13. Experience and levels of satisfaction with the levonorgestrel-releasing intrauterine system in China: a prospective multicenter survey

    Directory of Open Access Journals (Sweden)

    Zhao S

    2014-10-01

    Full Text Available Shuping Zhao,1 Jihong Deng,2 Yan Wang,3 Shiliang Bi,4 Xiaoye Wang,5 Wen Qin,6 Zirong Huang,7 Li Li,8 Xin Mi,9 Liping Han,10 Qing Chang,11 Jian Li12 1The Affiliated Hospital of the Medical College Qingdao University, Qingdao, 2Kunming Maternal and Child Health Hospital, Kunming, 3Hubei Maternity and Child Health Hospital, Wuhan, 4West China Second University Hospital, Sichuan University, Chengdu, 5Peking University Third Hospital, Beijing, 6Changzhou Maternity and Child Health Hospital, Affiliated to Nanjing Medical University, Jiangsu, 7The Affiliated Women’s Hospital of Fudan University, Shanghai, 8Guangzhou Women and Children’s Medical Center, Guangzhou, 9Maternity and Child Health Care Hospital, Shunyi District, Beijing, 10The First Affiliated Hospital of Zhengzhou University, Zhengzhou City, Henan, 11Southwest Hospital, Chongqing City, Chongqing, 12Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing, People’s Republic of China Background: Although surveys conducted in Western countries have shown that the levonorgestrel-releasing intrauterine system (LNG-IUS; Mirena® is well accepted by European women, its acceptance by Chinese women is not yet clearly known. The purpose of this study was to analyze the experiences and levels of satisfaction with Mirena among Chinese women living in 12 different cities. Methods: In total, 1,021 women who attended 21 medical centers for insertion of Mirena were invited to complete a questionnaire regarding their contraceptive decision at baseline (preinsertion, and two further questionnaires on their experience and satisfaction with Mirena at 3–6 months and 1 year after insertion. Results: At baseline, 36% of women self-reported heavy or very heavy menstrual bleeding, while 41% reported normal bleeding. The majority of women (98% were satisfied with the preinsertion counseling, during which contraceptive reliability was identified as the most important reason for

  14. Canadian Contraception Consensus (Part 3 of 4): Chapter 7--Intrauterine Contraception.

    Science.gov (United States)

    Black, Amanda; Guilbert, Edith; Costescu, Dustin; Dunn, Sheila; Fisher, William; Kives, Sari; Mirosh, Melissa; Norman, Wendy; Pymar, Helen; Reid, Robert; Roy, Geneviève; Varto, Hannah; Waddington, Ashley; Wagner, Marie-Soleil; Whelan, Anne Marie; Mansouri, Shireen

    2016-02-01

    To provide guidelines for health care providers on the use of contraceptive methods to prevent pregnancy and on the promotion of healthy sexuality. Overall efficacy of cited contraceptive methods, assessing reduction in pregnancy rate, safety, ease of use, and side effects; the effect of cited contraceptive methods on sexual health and general well-being; and the relative cost and availability of cited contraceptive methods in Canada. Published literature was retrieved through searches of Medline and The Cochrane Database from January 1994 to January 2015 using appropriate controlled vocabulary (e.g., contraception, sexuality, sexual health) and key words (e.g., contraception, family planning, hormonal contraception, emergency contraception). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies published in English from January 1994 to January 2015. Searches were updated on a regular basis in incorporated in the guideline to June 2015. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The quality of the evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). CHAPTER 7: INTRAUTERINE CONTRACEPTION: 1. Intrauterine contraceptives are as effective as permanent contraception methods. (II-2) 2. The use of levonorgestrel-releasing intrauterine system (LNG-IUS) 52 mg by patients taking tamoxifen is not associated with recurrence of breast cancer. (I) 3. Intrauterine contraceptives have a number of noncontraceptive benefits. The levonorgestrel-releasing intrauterine system (LNG-IUS) 52 mg significantly decreases menstrual blood loss (I) and dysmenorrhea. (II-2) Both the copper intrauterine

  15. Plant and safety system model

    International Nuclear Information System (INIS)

    Beltracchi, Leo

    1999-01-01

    The design and development of a digital computer-based safety system for a nuclear power plant is a complex process. The process of design and product development must result in a final product free of critical errors; operational safety of nuclear power plants must not be compromised. This paper focuses on the development of a safety system model to assist designers, developers, and regulators in establishing and evaluating requirements for a digital computer-based safety system. The model addresses hardware, software, and human elements for use in the requirements definition process. The purpose of the safety system model is to assist and serve as a guide to humans in the cognitive reasoning process of establishing requirements. The goals in the use of the model are to: (1) enhance the completeness of the requirements and (2) reduce the number of errors associated with the requirements definition phase of a project

  16. Safety balance: Analysis of safety systems

    International Nuclear Information System (INIS)

    Delage, M.; Giroux, C.

    1990-12-01

    Safety analysis, and particularly analysis of exploitation of NPPs is constantly affected by EDF and by the safety authorities and their methodologies. Periodic safety reports ensure that important issues are not missed on daily basis, that incidents are identified and that relevant actions are undertaken. French safety analysis method consists of three principal steps. First type of safety balance is analyzed at the normal start-up phase for each unit including the final safety report. This enables analysis of behaviour of units ten years after their licensing. Second type is periodic operational safety analysis performed during a few years. Finally, the third step consists of safety analysis of the oldest units with the aim to improve the safety standards. The three steps of safety analysis are described in this presentation in detail with the aim to present the objectives and principles. Examples of most recent exercises are included in order to illustrate the importance of such analyses

  17. System safety education focused on system management

    Science.gov (United States)

    Grose, V. L.

    1971-01-01

    System safety is defined and characteristics of the system are outlined. Some of the principle characteristics include role of humans in hazard analysis, clear language for input and output, system interdependence, self containment, and parallel analysis of elements.

  18. Software Safety Risk in Legacy Safety-Critical Computer Systems

    Science.gov (United States)

    Hill, Janice L.; Baggs, Rhoda

    2007-01-01

    Safety Standards contain technical and process-oriented safety requirements. Technical requirements are those such as "must work" and "must not work" functions in the system. Process-Oriented requirements are software engineering and safety management process requirements. Address the system perspective and some cover just software in the system > NASA-STD-8719.13B Software Safety Standard is the current standard of interest. NASA programs/projects will have their own set of safety requirements derived from the standard. Safety Cases: a) Documented demonstration that a system complies with the specified safety requirements. b) Evidence is gathered on the integrity of the system and put forward as an argued case. [Gardener (ed.)] c) Problems occur when trying to meet safety standards, and thus make retrospective safety cases, in legacy safety-critical computer systems.

  19. Optimization of nuclear safety systems

    International Nuclear Information System (INIS)

    Beninson, D.; Gonzalez, A.J.

    1981-01-01

    The paper presents an approach for selecting the level of ambition of nuclear safety by a process of optimization based on cost-benefit considerations. Optimization has been incorporated as a requirement for radiation protection, to keep doses ''as low as reasonably achievable''. In radiation protection, optimization takes account of the costs of protection and the costs of the detriment, minimizing the sum of both. Optimization of a nuclear safety system could conceptually treat similarly the cost of potential damages from nuclear accidents and the cost associated with achieving a given level of safety. Within the above framework a method of optimizing the design of nuclear safety systems is presented, and a simple case of redundancy by output voting techniques is given. (author)

  20. SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

    Energy Technology Data Exchange (ETDEWEB)

    Price, M; Fontenot, J [pF Biomedical Solutions LLC, Baton Rouge, LA (United States)

    2014-06-01

    Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandem placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components.

  1. SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

    International Nuclear Information System (INIS)

    Price, M; Fontenot, J

    2014-01-01

    Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandem placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components

  2. Cost-effectiveness analysis of levonorgestrel-releasing intrauterine system (LNG-IUS) 13.5 mg in contraception.

    Science.gov (United States)

    Trussell, James; Hassan, Fareen; Henry, Nathaniel; Pocoski, Jennifer; Law, Amy; Filonenko, Anna

    2014-05-01

    Levonorgestrel-releasing intrauterine system (LNG-IUS) 13.5 mg (total content) is a low-dose levonorgestrel intrauterine system for up to 3 years of use. This analysis evaluated the cost-effectiveness of LNG-IUS 13.5 mg in comparison with short-acting reversible contraceptive (SARC) methods in a cohort of young women in the United States from a third-party payer's perspective. A state transition model consisting of three mutually exclusive health states -- initial method, unintended pregnancy (UP) and subsequent method -- was developed. Cost-effectiveness of LNG-IUS 13.5 mg was assessed vs. SARC methods in a cohort of 1000 women aged 20-29 years. SARC methods comprise oral contraceptives (OC), ring, patch and injections, which are the methods commonly used by this cohort. Failure and discontinuation probabilities were based on published literature, contraceptive uptake was determined by the most recent data from the National Survey of Family Growth, and costs were taken from standard US databases. One-way sensitivity analysis was conducted around key inputs, while scenario analysis assessed a comparison between LNG-IUS 13.5 mg and the existing IUS, LNG-IUS 20 mcg/24 h. The key model output was cost per UP avoided. Compared to SARC methods, initiating contraception with LNG-IUS 13.5 mg resulted in fewer UP (64 UP vs. 276 UP) and lower total costs ($1,283,479 USD vs. $1,862,633 USD, a 31% saving) over the 3-year time horizon. Results were most sensitive to the probability of failure on OC, the probability of LNG-IUS 13.5 mg discontinuation and the cost of live births. Scenario analysis suggests that further cost savings may be generated with the initiation of LNG-IUS 20 mcg/24 h in place of SARC methods. From a third-party payer perspective, LNG-IUS 13.5 mg is a more cost-effective contraceptive option than SARC. Therefore, women switching from current SARC use to LNG-IUS 13.5 mg are likely to generate cost savings to third-party health care payers, driven

  3. Effects of intrauterine growth restriction on sleep and the cardiovascular system: The use of melatonin as a potential therapy?

    Science.gov (United States)

    Yiallourou, Stephanie R; Wallace, Euan M; Miller, Suzanne L; Horne, Rosemary S C

    2016-04-01

    Intrauterine growth restriction (IUGR) complicates 5-10% of pregnancies and is associated with increased risk of preterm birth, mortality and neurodevelopmental delay. The development of sleep and cardiovascular control are closely coupled and IUGR is known to alter this development. In the long-term, IUGR is associated with altered sleep and an increased risk of hypertension in adulthood. Melatonin plays an important role in the sleep-wake cycle. Experimental animal studies have shown that melatonin therapy has neuroprotective and cardioprotective effects in the IUGR fetus. Consequently, clinical trials are currently underway to assess the short and long term effects of antenatal melatonin therapy in IUGR pregnancies. Given melatonin's role in sleep regulation, this hormone could affect the developing infants' sleep-wake cycle and cardiovascular function after birth. In this review, we will 1) examine the role of melatonin as a therapy for IUGR pregnancies and the potential implications on sleep and the cardiovascular system; 2) examine the development of sleep-wake cycle in fetal and neonatal life; 3) discuss the development of cardiovascular control during sleep; 4) discuss the effect of IUGR on sleep and the cardiovascular system and 5) discuss the future implications of melatonin therapy in IUGR pregnancies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A randomized trial of levonorgestrel intrauterine system insertion 6 to 48 h compared to 6 weeks after vaginal delivery; lessons learned.

    Science.gov (United States)

    Stuart, Gretchen S; Lesko, Catherine R; Stuebe, Alison M; Bryant, Amy G; Levi, Erika E; Danvers, Antoinette I

    2015-04-01

    The objective of this randomized trial was to compare breastfeeding among women who received a levonorgestrel-releasing intrauterine system within 6-48 h (early) or 4-6 weeks (standard) after an uncomplicated vaginal birth. Analysis groups of 86 women in each arm were needed to demonstrate a 20% difference in any breastfeeding. Thirty-five women were randomized to the early (N=17) and standard (N=18) arms. The combination of unsuccessful placement (2/17; 12%), expulsions (7/17; 41%) and removals (3/17; 18%) reached 71% (12/17) in the early arm, so the study was stopped. In our small study cohort, levonorgestrel-releasing intrauterine system insertion between 6 and 48 h after vaginal birth was associated with a high rate of expulsion or removal soon after insertion. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Intrauterine insemination versus intracervical insemination in donor sperm treatment

    NARCIS (Netherlands)

    Kop, Petronella Al; Mochtar, Monique H.; O'Brien, Paul A.; van der Veen, Fulco; van Wely, Madelon

    2018-01-01

    The first-line treatment in donor sperm treatment consists of inseminations that can be done by intrauterine insemination (IUI) or by intracervical insemination (ICI). To compare the effectiveness and safety of intrauterine insemination (IUI) and intracervical insemination (ICI) in women who start

  6. Safety of mechanical devices. Safety of automation systems

    International Nuclear Information System (INIS)

    Pahl, G.; Schweizer, G.; Kapp, K.

    1985-01-01

    The paper deals with the classic procedures of safety engineering in the sectors mechanical engineering, electrical and energy engineering, construction and transport, medicine technology and process technology. Particular stress is laid on the safety of automation systems, control technology, protection of mechanical devices, reactor safety, mechanical constructions, transport systems, railway signalling devices, road traffic and protection at work in chemical plans. (DG) [de

  7. [Intrauterine infections].

    Science.gov (United States)

    Jakobovits, Akos

    2006-09-10

    A broad variety of microorganisms are capable of causing fetal infections. Among viral agents prominent are the human cytomegaly virus (HCMV), herpes simplex virus (HSV), human immundeficiency virus (HIV), varicella, herpes zooster, rubella, parvovirus B19, measles and the hepatitis B and C viruses. Protozoa such as toxoplasma and spirocheta pallida, causing congenital syphilis are equally important. Bacterial infections are responsible for in uterus aquired listeriosis, tuberculosis, and group B streptococcus infections. Fungi including candida albicans complete the circle of infections pathogens. Infectious microrganisms may reach the fetus through the placenta are may ascend through the birth canal. The quoted pathological agents threaten the health and life of the fetus directly by the biological derangements they cause and also by inducing abortion or premature birth. The clinical manifestations include retarded growth, central nervous system damage and skin lesions. The invariable therapeutic measures vary but in general, are limited value in cases of in utero acquired infections.

  8. Antenatal risk factor for intrauterine growth restriction

    Directory of Open Access Journals (Sweden)

    N. D. Guliyev

    2015-01-01

    Full Text Available Objective: to study pregnancy and delivery characteristics in mothers who have given birth to infants with intrauterine growth restriction. Pregnancy and delivery outcomes were studied in 315 mothers who had given birth to infants with intrauterine growth restriction (a study group. The studies have shown that toxemia, anemia, and preeclampsia prevent physiological pregnancy that concurrent with placental insufficiency leads to serious metabolic disturbances in the mother-placenta-fetus system and eventually lead to intrauterine growth restriction. A set of pathological factors of pregnancy required surgical delivery in mothers with fetal growth restriction.

  9. Levonorgestrel-releasing intrauterine system for treatment of heavy menstrual bleeding in adolescents with Glanzmann's Thrombasthenia: illustrated case series.

    Science.gov (United States)

    Lu, Meiqiu; Yang, Xin

    2018-02-27

    Glanzmann's Thrombasthenia (GT) is an inherited genetic disorder caused by defects in the platelet membrane glycoproteins IIb/IIIA, and is associated with heavy menstrual bleeding (HMB). HMB is a common complication in female patients, and many adolescent girls with this disease have issues with HMB beginning at menarche. The available treatment modalities including anti-fibrinolytics, nonsteroidal anti-inflammatory drugs (NSAIDs) and hormonal therapies though are effective, their associated side effects, limited efficacy and the poor compliance is a challenge in management of HMB. Levonorgestrel-releasing intrauterine system (LNG-IUS) has been a potential alternative to overcome this challenge. The use of the LNG-IUS for the management of HMB in adolescents with GT is explored in this case series. Two adolescents diagnosed with GT and received the LNG-IUS as treatment modality for management of HMB is discussed in this case series. For patients with poor compliance to oral hormonal therapies, the use of LNG-IUS is associated with a significant reduction of menstrual blood loss along with improved quality of life. These findings support the use of LNG-IUS to control adolescent GT-related HMB.

  10. Assessment of Fetal Autonomic Nervous System Activity by Fetal Magnetocardiography: Comparison of Normal Pregnancy and Intrauterine Growth Restriction

    Directory of Open Access Journals (Sweden)

    Akimune Fukushima

    2011-01-01

    Full Text Available Objective. To clarify the developmental activity of the autonomic nervous system (ANS of the normal fetus and intrauterine growth restriction (IUGR cases using fetal magnetocardiography (FMCG. Subjects and Methods. Normal pregnancy (n=35 and IUGR (n=12 cases at 28–39 and 32–37 weeks of gestation, respectively, were included in this study. The R-R interval variability was used to calculate the coefficient of variance (CVRR and low frequency/high frequency (LF/HF ratio. Results. The value of CVRR in the normal pregnancy group displayed a slight increasing trend with gestational age. However, no such trend was observed in the IUGR group. In contrast, the LF/HF ratio in both the normal pregnancy group and the IUGR group clearly increased over the gestational period; the normal group showing statistical significance. Conclusion. The development of fetal ANS activity in IUGR cases might differ from that observed in the normal pregnancy group, and this may facilitate early detection of IUGR.

  11. Acceptability of the levonorgestrel releasing-intrauterine system and etonogestrel implant: one-year results of an observational study.

    Science.gov (United States)

    Short, Mary; Dallay, Dominique; Omokanye, Salmon; Hanisch, Jens Ulrich; Inki, Pirjo

    2012-02-01

    To analyse the acceptability and patterns of use of the levonorgestrel releasing-intrauterine system (LNG-IUS) and the etonogestrel releasing-subdermal implant (ENG implant) among young European women. A total of 454 women aged 20-35 years opting to switch their method of contraception from oral contraception to the LNG-IUS or ENG implant, were recruited in an observational study in four different European countries (France, Ireland, Slovakia and the United Kingdom). The present paper reports the interim results of the study at 12 months of observation. Data from 311 subjects (211 using the LNG-IUS and 100 using the ENG implant), with at least one follow-up visit after insertion, were analysed. The cumulative continuation rates at 12 months for the LNG-IUS and ENG implant were 93% and 86%, respectively. Most women were satisfied with their method of contraception after one year of follow-up (80% in the LNG-IUS group and 66% in the ENG implant group). Both the LNG-IUS and the ENG implant are highly acceptable contraceptive options among women with previous experience of oral contraceptive use. The highest continuation and satisfaction rates were observed with the LNG-IUS.

  12. Safety design guide for safety related systems for CANDU 9

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of); Wright, A.C.D. [Atomic Energy of Canada Ltd., Toronto (Canada)

    1996-03-01

    In general, two types of safety related systems and structures exist in the nuclear plant; The one is a systems and structures which perform safety functions during the normal operation of the plant, and the other is a systems and structures which perform safety functions to mitigate events caused by failure of the normally operating systems or by naturally occurring phenomena. In this safety design guide, these systems are identified in detail, and the major events for which the safety functions are required and the major safety requirements are identified in the list. As the probabilistic safety assessments are completed during the course of the project, additions or deletions to the list may be justified. 3 tabs. (Author) .new.

  13. Safety in nuclear power systems

    International Nuclear Information System (INIS)

    Myers, L.C.

    1987-05-01

    This paper discusses the issue of safety in complex energy systems and provides brief accounts of some of the most serious reactor accidents that have occurred to date. Details are also provided of Ontario Hydro's problems with Unit 2 at Pickering

  14. Firefighter Safety for PV Systems

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Spataru, Sergiu

    2015-01-01

    An important and highly discussed safety issue for photovoltaic (PV) systems is that as long as the PV panels are illuminated, a high voltage is present at the PV string terminals and cables between the string and inverters that is independent of the state of the inverter's dc disconnection switch...

  15. System Safety in Aircraft Acquisition

    Science.gov (United States)

    1984-01-01

    Factors Engineering, Master Plan, FY83" (for research) realizes that "Potential hazards in the area of human performance and behavior must also be... aggresive system safety programs -- i.e., the contractor would be exempt from strict liability if, assuming certain other conditions are obtained, he

  16. The Daresbury personnel safety system

    International Nuclear Information System (INIS)

    Poole, D.E.; Ring, T.

    1989-01-01

    The personnel safety system designed for the SRS at Daresbury is a unified system covering the three accelerators of the source itself, the beamlines and the experimental stations. The system has also been applied to the experimental areas of the Nuclear Structure Facility, and is therefore established as a site standard. A dual guardline interlock module forms a building block for a relay based interlock system completely independent of the machine control system, although comprehensive monitoring of the system status via the control system computer is a feature. An outline of the design criteria adopted for the system is presented together with a more detailed description of the philosophy of the guardline logic and the way this is implemented in a standard modular form. The emphasis is on the design features of a modern microprocessor based variant of the original SRS system. Experience with the original system during build-up and operation of the SRS facility is described. 2 refs., 4 figs

  17. Safety implications of control systems

    International Nuclear Information System (INIS)

    Smith, O.L.

    1983-01-01

    The Safety Implications of Control Systems Program has three major activities in support of USI-A47. The first task is a failure mode and effects analysis of all plant systems which may potentially induce control system disturbance that have safety implications. This task has made a preliminary study of overfill events and recommended cases for further analysis on the hybrid simulator. Work continues on overcooling and undercooling. A detailed investigation of electric power network is in progress. LERs are providing guidance on important failure modes that will provide initial conditions for further simulator studies. The simulator taks is generating a detailed model of the control system supported by appropriate neutronics, hydraulics, and thermodynamics submodels of all other principal plant components. The simulator is in the last stages of development. Checkout calculations are in progress to establish model stability, robustness, and qualitative credibility. Verification against benchmark codes and plant data will follow

  18. System safety education focused on industrial engineering

    Science.gov (United States)

    Johnston, W. L.; Morris, R. S.

    1971-01-01

    An educational program, designed to train students with the specific skills needed to become safety specialists, is described. The discussion concentrates on application, selection, and utilization of various system safety analytical approaches. Emphasis is also placed on the management of a system safety program, its relationship with other disciplines, and new developments and applications of system safety techniques.

  19. Postplacental intrauterine device expulsion by 12 weeks: a prospective cohort study.

    Science.gov (United States)

    Goldthwaite, Lisa M; Sheeder, Jeanelle; Hyer, Jennifer; Tocce, Kristina; Teal, Stephanie B

    2017-12-01

    An intrauterine device placed immediately following a delivery can serve as an effective and safe contraceptive strategy in the postpartum period. There is limited evidence that the levonorgestrel intrauterine system may have a higher rate of expulsion compared to the copper intrauterine device; however, rates of expulsion for these 2 intrauterine device types have not been compared directly. We sought to compare expulsion rates by 12 weeks' postpartum for the levonorgestrel intrauterine system and copper intrauterine device. We enrolled women who received postplacental intrauterine devices at 2 urban hospitals. Eligible women were ≥18 years old, English- or Spanish-speaking, with singleton vaginal delivery at ≥35 weeks' gestation. Intrauterine devices were inserted within 10 minutes of placental delivery by trained providers using ring forceps or the operator's hand. Intrauterine device location was evaluated via abdominal ultrasound at 24-48 hours' postpartum, and via transvaginal ultrasound 6 and 12 weeks later, categorizing position of the intrauterine device at the fundus, below the fundus but above the internal os, any part of the intrauterine device below the internal os (partial expulsion), or no intrauterine device visualized. Outcomes included intrauterine device expulsion and method continuation. We used multivariable logistic regression to identify factors associated with expulsion. We enrolled 123 women ages 18-40 years. Of these, 68 (55%) initiated levonorgestrel intrauterine system and 55 (45%) initiated copper intrauterine device. Groups were similar except more copper intrauterine device users were Hispanic (66% vs 38%) and fewer were primiparous (16% vs 31%). Among the 96 (78%) with 12-week follow-up, expulsion was higher for levonorgestrel intrauterine system users (21/55 or 38%) than for copper intrauterine device users (8/41 or 20%) (odds ratio, 2.55; 95% confidence interval, 0.99-6.55; P = .05). At 24 hours' postpartum, there was no

  20. Radiation safety systems at the NSLS

    International Nuclear Information System (INIS)

    Dickinson, T.

    1987-04-01

    This report describes design principles that were used to establish the radiation safety systems at the National Synchrotron Light Source. The author described existing safety systems and the history of partial system failures. 1 fig

  1. Nuclear power systems: Their safety

    International Nuclear Information System (INIS)

    Myers, L.C.

    1993-01-01

    Mankind utilizes energy in many forms and from a variety of sources. Canada is one of a growing number of countries which have chosen to embrace nuclear-electric generation as a component of their energy systems. As of August 1992 there were 433 power reactors operating in 35 countries and accounting for more than 15% of the world's production of electricity. In 1992, thirteen countries derived at least 25% of their electricity from nuclear units, with France leading at nearly 70%. In the same year, Canada produced about 16% of its electricity from nuclear units. Some 68 power reactors are under construction in 16 countries, enough to expand present generating capacity by close to 20%. No human endeavour carries the guarantee of perfect safety and the question of whether or not nuclear-electric generation represents an 'acceptable' risk to society has long been vigorously debated. Until the events of late April 1986, nuclear safety had indeed been an issue for discussion, for some concern, but not for alarm. The accident at the Chernobyl reactor in the USSR has irrevocably changed all that. This disaster brought the matter of nuclear safety back into the public mind in a dramatic fashion. This paper discusses the issue of safety in complex energy systems and provides brief accounts of some of the most serious reactor accidents which have occurred to date. (author). 7 refs

  2. Intrauterine device insertion in the postpartum period: a systematic review.

    Science.gov (United States)

    Sonalkar, Sarita; Kapp, Nathalie

    2015-02-01

    Given new research on postpartum placement of levonorgestrel and copper intrauterine devices (IUDs), our objective was to update a prior systematic review of the safety and expulsion rates of postpartum IUDs. We searched MEDLINE, CENTRAL, LILACS, POPLINE, Web of Science, and ClinicalTrials.gov databases for articles between the database inception until July 2013. We included studies that compared IUD insertion time intervals and routes during the postpartum period. We used standard abstract forms and the United States Preventive Services Task Force grading system to summarise and assess the quality of the evidence. We included 18 articles. New evidence suggests that a levonorgestrel releasing-intrauterine system (LNG-IUS) insertion within 48 hours of delivery is safe. Postplacental insertion and insertion between 10 minutes and 48 hours after delivery result in higher expulsion rates than insertion 4 to 6 weeks postpartum, or non-postpartum insertion. Insertion at the time of caesarean section is associated with lower expulsion rates than postplacental insertion at the time of vaginal delivery. This review supports the evidence that insertion of an intrauterine contraceptive within the first 48 hours of vaginal or caesarean delivery is safe. Expulsion rates should be further studied in larger randomised controlled trials.

  3. Integrated therapy safety management system.

    Science.gov (United States)

    Podtschaske, Beatrice; Fuchs, Daniela; Friesdorf, Wolfgang

    2013-09-01

    The aim is to demonstrate the benefit of the medico-ergonomic approach for the redesign of clinical work systems. Based on the six layer model, a concept for an 'integrated therapy safety management' is drafted. This concept could serve as a basis to improve resilience. The concept is developed through a concept-based approach. The state of the art of safety and complexity research in human factors and ergonomics forms the basis. The findings are synthesized to a concept for 'integrated therapy safety management'. The concept is applied by way of example for the 'medication process' to demonstrate its practical implementation. The 'integrated therapy safety management' is drafted in accordance with the six layer model. This model supports a detailed description of specific work tasks, the corresponding responsibilities and related workflows at different layers by using the concept of 'bridge managers'. 'Bridge managers' anticipate potential errors and monitor the controlled system continuously. If disruptions or disturbances occur, they respond with corrective actions which ensure that no harm results and they initiate preventive measures for future procedures. The concept demonstrates that in a complex work system, the human factor is the key element and final authority to cope with the residual complexity. The expertise of the 'bridge managers' and the recursive hierarchical structure results in highly adaptive clinical work systems and increases their resilience. The medico-ergonomic approach is a highly promising way of coping with two complexities. It offers a systematic framework for comprehensive analyses of clinical work systems and promotes interdisciplinary collaboration. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  4. Integrated therapy safety management system

    Science.gov (United States)

    Podtschaske, Beatrice; Fuchs, Daniela; Friesdorf, Wolfgang

    2013-01-01

    Aims The aim is to demonstrate the benefit of the medico-ergonomic approach for the redesign of clinical work systems. Based on the six layer model, a concept for an ‘integrated therapy safety management’ is drafted. This concept could serve as a basis to improve resilience. Methods The concept is developed through a concept-based approach. The state of the art of safety and complexity research in human factors and ergonomics forms the basis. The findings are synthesized to a concept for ‘integrated therapy safety management’. The concept is applied by way of example for the ‘medication process’ to demonstrate its practical implementation. Results The ‘integrated therapy safety management’ is drafted in accordance with the six layer model. This model supports a detailed description of specific work tasks, the corresponding responsibilities and related workflows at different layers by using the concept of ‘bridge managers’. ‘Bridge managers’ anticipate potential errors and monitor the controlled system continuously. If disruptions or disturbances occur, they respond with corrective actions which ensure that no harm results and they initiate preventive measures for future procedures. The concept demonstrates that in a complex work system, the human factor is the key element and final authority to cope with the residual complexity. The expertise of the ‘bridge managers’ and the recursive hierarchical structure results in highly adaptive clinical work systems and increases their resilience. Conclusions The medico-ergonomic approach is a highly promising way of coping with two complexities. It offers a systematic framework for comprehensive analyses of clinical work systems and promotes interdisciplinary collaboration. PMID:24007448

  5. The ATLAS Detector Safety System

    CERN Multimedia

    Helfried Burckhart; Kathy Pommes; Heidi Sandaker

    The ATLAS Detector Safety System (DSS) has the mandate to put the detector in a safe state in case an abnormal situation arises which could be potentially dangerous for the detector. It covers the CERN alarm severity levels 1 and 2, which address serious risks for the equipment. The highest level 3, which also includes danger for persons, is the responsibility of the CERN-wide system CSAM, which always triggers an intervention by the CERN fire brigade. DSS works independently from and hence complements the Detector Control System, which is the tool to operate the experiment. The DSS is organized in a Front- End (FE), which fulfills autonomously the safety functions and a Back-End (BE) for interaction and configuration. The overall layout is shown in the picture below. ATLAS DSS configuration The FE implementation is based on a redundant Programmable Logical Crate (PLC) system which is used also in industry for such safety applications. Each of the two PLCs alone, one located underground and one at the s...

  6. Different Bleeding Patterns with the Use of Levonorgestrel Intrauterine System: Are They Associated with Changes in Uterine Artery Blood Flow?

    Directory of Open Access Journals (Sweden)

    Carlo Bastianelli

    2014-01-01

    Full Text Available Objective. Evaluate if different bleeding patterns associated with the use of the levonorgestrel intrauterine system (LNG-IUS are associated with different uterine and endometrial vascularization patterns, as evidenced by ultrasound power Doppler analysis. Methodology. A longitudinal study, with each subject acting as its own control was conducted between January 2010 and December 2012. Healthy volunteers with a history of heavy but cyclic and regular menstrual cycles were enrolled in the study. Ultrasonographic examination was performed before and after six months of LNG-IUS placement: uterine volume, endometrial thickness, and subendometrial and myometrial Doppler blood flow patterns have been evaluated. Results. A total of 32 women were enrolled out of 186 initially screened. At six months of follow-up, all subjects showed a reduction in menstrual blood loss; for analysis, they were retrospectively divided into 3 groups: normal cycling women (Group I, amenorrheic women (Group II, and women with prolonged bleedings (Group III. Intergroup analysis documented a statistically significant difference in endometrial thickness among the three groups; in addition, mean pulsatility index (PI and resistance index (RI in the spiral arteries were significantly lower in Group I and Group III compared to Group II. This difference persisted also when comparing—within subjects of Group III—mean PI and RI mean values before and after insertion. Conclusions. The LNG-IUS not only altered endometrial thickness, but—in women with prolonged bleedings—also significantly changed uterine artery blood flow. Further studies are needed to confirm these results and enable gynecologists to properly counsel women, improving initial continuation rates.

  7. Intrauterine Insemination (IUI)

    Science.gov (United States)

    ... IUI) Overview Intrauterine insemination ( IUI ) — a type of artificial insemination — is a procedure for treating infertility. Sperm that ... more eggs to be fertilized. Older types of artificial insemination placed the sperm in the vagina. While this ...

  8. Central Nervous System Effects of Intrauterine Zika Virus Infection: A Pictorial Review.

    Science.gov (United States)

    Ribeiro, Bianca Guedes; Werner, Heron; Lopes, Flávia P P L; Hygino da Cruz, L Celso; Fazecas, Tatiana M; Daltro, Pedro A N; Nogueira, Renata A

    2017-10-01

    Relatively few agents have been associated with congenital infections involving the brain. One such agent is the Zika virus, which has caused several outbreaks worldwide and has spread in the Americas since 2015. The Zika virus is an arbovirus transmitted by infected female mosquito vectors, such as the Aedes aegypti mosquito. This virus has been commonly associated with congenital infections of the central nervous system and has greatly increased the rates of microcephaly. Ultrasonography (US) remains the method of choice for fetal evaluation of congenital Zika virus infection. For improved assessment of the extent of the lesions, US should be complemented by magnetic resonance (MR) imaging. Postnatal computed tomography and MR imaging can also unveil additional findings of central nervous system involvement, such as microcephaly with malformation of cortical development, ventriculomegaly, and multifocal calcifications in the cortical-subcortical junction, along with associated cortical atrophy. The calcifications may be punctate, dystrophic, linear, or coarse and may follow a predominantly bandlike distribution. A small anterior fontanelle with prematurely closed sutures is also observed with Zika virus infection. In this review, the prenatal and postnatal neurologic imaging findings of congenital Zika virus infection are covered. Radiologists must be aware of this challenging entity and have knowledge of the various patterns that may be depicted with each imaging modality and the main differential diagnosis of the disease. As in other neurologic infections, serial imaging is able to help demonstrate the progression of the findings. © RSNA, 2017.

  9. Safety performance monitoring of autonomous marine systems

    International Nuclear Information System (INIS)

    Thieme, Christoph A.; Utne, Ingrid B.

    2017-01-01

    The marine environment is vast, harsh, and challenging. Unanticipated faults and events might lead to loss of vessels, transported goods, collected scientific data, and business reputation. Hence, systems have to be in place that monitor the safety performance of operation and indicate if it drifts into an intolerable safety level. This article proposes a process for developing safety indicators for the operation of autonomous marine systems (AMS). The condition of safety barriers and resilience engineering form the basis for the development of safety indicators, synthesizing and further adjusting the dual assurance and the resilience based early warning indicator (REWI) approaches. The article locates the process for developing safety indicators in the system life cycle emphasizing a timely implementation of the safety indicators. The resulting safety indicators reflect safety in AMS operation and can assist in planning of operations, in daily operational decision-making, and identification of improvements. Operation of an autonomous underwater vehicle (AUV) exemplifies the process for developing safety indicators and their implementation. The case study shows that the proposed process leads to a comprehensive set of safety indicators. It is expected that application of the resulting safety indicators consequently will contribute to safer operation of current and future AMS. - Highlights: • Process for developing safety indicators for autonomous marine systems. • Safety indicators based on safety barriers and resilience thinking. • Location of the development process in the system lifecycle. • Case study on AUV demonstrating applicability of the process.

  10. A comparison of intrauterine balloon, intrauterine contraceptive device and hyaluronic acid gel in the prevention of adhesion reformation following hysteroscopic surgery for Asherman syndrome: a cohort study.

    Science.gov (United States)

    Lin, Xiaona; Wei, Minling; Li, T C; Huang, Qiongxiao; Huang, Dong; Zhou, Feng; Zhang, Songying

    2013-10-01

    To compare the efficacy of intrauterine balloon, intrauterine contraceptive device and hyaluronic acid gel in the prevention of the adhesion reformation after hysteroscopic adhesiolysis for Asherman's syndrome. Retrospective cohort study of 107 women with Asherman's syndrome who were treated with hysteroscopic division of intrauterine adhesions. After hysteroscopic adhesiolysis, 20 patients had intrauterine balloon inserted, 28 patients had intrauterine contraceptive device (IUD) fitted, 18 patients had hyaluronic acid gel instilled into the uterine cavity, and 41 control subjects did not have any of the three additional treatment measures. A second-look hysteroscopy was performed in all cases, and the effect of hysteroscopic adhesiolysis was scored by the American Fertility Society classification system. Both the intrauterine balloon group and the IUD group achieved significantly (Pintrauterine balloon or intrauterine device is more effective than the use of hyaluronic acid gel in the prevention of intra-uterine adhesion reformation. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Sub system and component level safety classification evaluation and identification for tank farm safety systems

    International Nuclear Information System (INIS)

    JANICEK, G.P.

    2001-01-01

    This document provides the safety classification, and classification rationale, for all elements of (some) Tank Farm Safety Systems identified in the Tank Farms Final Safety Analyses. It also contains the official Safety Equipment List (SEL) for the safety systems evaluated. The initial issue of this document does not address all Tank Farm safety systems. The remainder will be addressed, and incorporated in this document, in subsequent revisions

  12. Considerations on nuclear reactor passive safety systems

    International Nuclear Information System (INIS)

    2016-01-01

    After having indicated some passive safety systems present in electronuclear reactors (control bars, safety injection system accumulators, reactor cooling after stoppage, hydrogen recombination systems), this report recalls the main characteristics of passive safety systems, and discusses the main issues associated with the assessment of new passive systems (notably to face a sustained loss of electric supply systems or of cold water source) and research axis to be developed in this respect. More precisely, the report comments the classification of safety passive systems as it is proposed by the IAEA, outlines and comments specific aspects of these systems regarding their operation and performance. The next part discusses the safety approach, the control of performance of safety passive systems, issues related to their reliability, and the expected contribution of R and D (for example: understanding of physical phenomena which have an influence of these systems, capacities of simulation of these phenomena, needs of experimentations to validate simulation codes)

  13. 76 FR 14592 - Safety Management System; Withdrawal

    Science.gov (United States)

    2011-03-17

    ...-06A] RIN 2120-AJ15 Safety Management System; Withdrawal AGENCY: Federal Aviation Administration (FAA... (``product/ service providers'') to develop a Safety Management System (SMS). The FAA is withdrawing the... management with a set of robust decision-making tools to use to improve safety. The FAA received 89 comments...

  14. A randomized clinical trial to compare levonorgestrel-releasing intrauterine system (Mirena vs trans-cervical endometrial resection for treatment of menorrhagia

    Directory of Open Access Journals (Sweden)

    Ghazizadeh S

    2011-07-01

    Full Text Available Shirin Ghazizadeh1, Fatemeh Bakhtiari1, Haleh Rahmanpour2, Fatemeh Davari-Tanha1, Fatemeh Ramezanzadeh11Valie-Asr Reproductive Health Research Center, Valie-Asr Hospital, Tehran University of Medical Sciences, Tehran, Iran; 2Department of Obstetrics and Gynecology, Ayatollah Mousavi Hospital, Zanjan, IranObjective: To compare the acceptability, efficacy, adverse effects, and user satisfaction of the levonorgestrel intrauterine system (LNG-IUS and trans-cervical resection of the endometrium (TCRE for the treatment of menorrhagia.Method: 104 women with menorrhagia were divided into 2 groups: 52 women had the LNG-IUS inserted and 52 underwent TCRE. Menstrual pattern, pictorial blood loss assessment chart score, adverse effects, and rates of acceptability and satisfaction, were recorded at 6 and 12 months after the procedure.Results: After a year there were reductions of 93.9% and 88.4% in menstrual blood loss in the TCRE and LNG-IUS groups, respectively. Amenorrhea was more common in the TCRE group and spotting and systemic effects in the LNG-IUS group. Satisfaction rates of the TCRE group were higher than the LNG-IUS group (80.8% vs 69.2%, but the difference was not statistically significant.Conclusion: Although both treatments were found to be equally effective, LNG-IUS was less invasive and can be advised for younger women with a desire to preserve fertility.Keywords: menorrhagia, trans-cervical endometrial resection, levonorgestrel-releasing intrauterine system

  15. Safety Management System in Croatia Control Ltd.

    OpenAIRE

    Pavlin, Stanislav; Sorić, Vedran; Bilać, Dragan; Dimnik, Igor; Galić, Daniel

    2009-01-01

    International Civil Aviation Organization and other international aviation organizations regulate the safety in civil aviation. In the recent years the International Civil Aviation Organization has introduced the concept of the safety management system through several documents among which the most important is the 2006 Safety Management Manual. It treats the safety management system in all the segments of civil aviation, from carriers, aerodromes and air traffic control to design, constructi...

  16. System Design and the Safety Basis

    International Nuclear Information System (INIS)

    Ellingson, Darrel

    2008-01-01

    The objective of this paper is to present the Bechtel Jacobs Company, LLC (BJC) Lessons Learned for system design as it relates to safety basis documentation. BJC has had to reconcile incomplete or outdated system description information with current facility safety basis for a number of situations in recent months. This paper has relevance in multiple topical areas including documented safety analysis, decontamination and decommissioning (D and D), safety basis (SB) implementation, safety and design integration, potential inadequacy of the safety analysis (PISA), technical safety requirements (TSR), and unreviewed safety questions. BJC learned that nuclear safety compliance relies on adequate and well documented system design information. A number of PIS As and TSR violations occurred due to inadequate or erroneous system design information. As a corrective action, BJC assessed the occurrences caused by systems design-safety basis interface problems. Safety systems reviewed included the Molten Salt Reactor Experiment (MSRE) Fluorination System, K-1065 fire alarm system, and the K-25 Radiation Criticality Accident Alarm System. The conclusion was that an inadequate knowledge of system design could result in continuous non-compliance issues relating to nuclear safety. This was especially true with older facilities that lacked current as-built drawings coupled with the loss of 'historical knowledge' as personnel retired or moved on in their careers. Walkdown of systems and the updating of drawings are imperative for nuclear safety compliance. System design integration with safety basis has relevance in the Department of Energy (DOE) complex. This paper presents the BJC Lessons Learned in this area. It will be of benefit to DOE contractors that manage and operate an aging population of nuclear facilities

  17. System Design and the Safety Basis

    Energy Technology Data Exchange (ETDEWEB)

    Ellingson, Darrel

    2008-05-06

    The objective of this paper is to present the Bechtel Jacobs Company, LLC (BJC) Lessons Learned for system design as it relates to safety basis documentation. BJC has had to reconcile incomplete or outdated system description information with current facility safety basis for a number of situations in recent months. This paper has relevance in multiple topical areas including documented safety analysis, decontamination & decommissioning (D&D), safety basis (SB) implementation, safety and design integration, potential inadequacy of the safety analysis (PISA), technical safety requirements (TSR), and unreviewed safety questions. BJC learned that nuclear safety compliance relies on adequate and well documented system design information. A number of PIS As and TSR violations occurred due to inadequate or erroneous system design information. As a corrective action, BJC assessed the occurrences caused by systems design-safety basis interface problems. Safety systems reviewed included the Molten Salt Reactor Experiment (MSRE) Fluorination System, K-1065 fire alarm system, and the K-25 Radiation Criticality Accident Alarm System. The conclusion was that an inadequate knowledge of system design could result in continuous non-compliance issues relating to nuclear safety. This was especially true with older facilities that lacked current as-built drawings coupled with the loss of 'historical knowledge' as personnel retired or moved on in their careers. Walkdown of systems and the updating of drawings are imperative for nuclear safety compliance. System design integration with safety basis has relevance in the Department of Energy (DOE) complex. This paper presents the BJC Lessons Learned in this area. It will be of benefit to DOE contractors that manage and operate an aging population of nuclear facilities.

  18. Safety assessment for Generation IV nuclear systems

    International Nuclear Information System (INIS)

    Leahy, T.J.

    2012-01-01

    The Generation IV International Forum (GIF) Risk and Safety Working Group (RSWG) was created to develop an effective approach for the safety of Generation IV advanced nuclear energy systems. Recent RSWG work has focused on the definition of an integrated safety assessment methodology (ISAM) for evaluating the safety of Generation IV systems. ISAM is an integrated 'tool-kit' consisting of 5 analytical techniques that are available and matched to appropriate stages of Generation IV system concept development: 1) qualitative safety features review - QSR, 2) phenomena identification and ranking table - PIRT, 3) objective provision tree - OPT, 4) deterministic and phenomenological analyses - DPA, and 5) probabilistic safety analysis - PSA. The integrated methodology is intended to yield safety-related insights that help actively drive the evolving design throughout the technology development cycle, potentially resulting in enhanced safety, reduced costs, and shortened development time

  19. Safety System for a Towed Array

    Science.gov (United States)

    2017-09-25

    300196 1 of 13 SAFETY SYSTEM FOR A TOWED SOURCE STATEMENT OF GOVERNMENT INTEREST [0001] The invention described herein may be manufactured...invention is a towed array safety system and method of use that prevents the loss of a towed array cable and towed array handling system in the event of a...tension surge while retaining required safety features of the towed array handling system . (2) Description of the Prior Art [0004] There have

  20. Intermediate probabilistic safety assessment approach for safety critical digital systems

    International Nuclear Information System (INIS)

    Taeyong, Sung; Hyun Gook, Kang

    2001-01-01

    Even though the conventional probabilistic safety assessment methods are immature for applying to microprocessor-based digital systems, practical needs force to apply it. In the Korea, UCN 5 and 6 units are being constructed and Korean Next Generation Reactor is being designed using the digital instrumentation and control equipment for the safety related functions. Korean regulatory body requires probabilistic safety assessment. This paper analyzes the difficulties on the assessment of digital systems and suggests an intermediate framework for evaluating their safety using fault tree models. The framework deals with several important characteristics of digital systems including software modules and fault-tolerant features. We expect that the analysis result will provide valuable design feedback. (authors)

  1. Software Quality Assurance for Nuclear Safety Systems

    International Nuclear Information System (INIS)

    Sparkman, D R; Lagdon, R

    2004-01-01

    The US Department of Energy has undertaken an initiative to improve the quality of software used to design and operate their nuclear facilities across the United States. One aspect of this initiative is to revise or create new directives and guides associated with quality practices for the safety software in its nuclear facilities. Safety software includes the safety structures, systems, and components software and firmware, support software and design and analysis software used to ensure the safety of the facility. DOE nuclear facilities are unique when compared to commercial nuclear or other industrial activities in terms of the types and quantities of hazards that must be controlled to protect workers, public and the environment. Because of these differences, DOE must develop an approach to software quality assurance that ensures appropriate risk mitigation by developing a framework of requirements that accomplishes the following goals: (sm b ullet) Ensures the software processes developed to address nuclear safety in design, operation, construction and maintenance of its facilities are safe (sm b ullet) Considers the larger system that uses the software and its impacts (sm b ullet) Ensures that the software failures do not create unsafe conditions Software designers for nuclear systems and processes must reduce risks in software applications by incorporating processes that recognize, detect, and mitigate software failure in safety related systems. It must also ensure that fail safe modes and component testing are incorporated into software design. For nuclear facilities, the consideration of risk is not necessarily sufficient to ensure safety. Systematic evaluation, independent verification and system safety analysis must be considered for software design, implementation, and operation. The software industry primarily uses risk analysis to determine the appropriate level of rigor applied to software practices. This risk-based approach distinguishes safety

  2. INTEGRATED SAFETY MANAGEMENT SYSTEM SAFETY CULTURE IMPROVEMENT INITIATIVE

    Energy Technology Data Exchange (ETDEWEB)

    MCDONALD JA JR

    2009-01-16

    In 2007, the Department of Energy (DOE) identified safety culture as one of their top Integrated Safety Management System (ISMS) related priorities. A team was formed to address this issue. The team identified a consensus set of safety culture principles, along with implementation practices that could be used by DOE, NNSA, and their contractors. Documented improvement tools were identified and communicated to contractors participating in a year long pilot project. After a year, lessons learned will be collected and a path forward determined. The goal of this effort was to achieve improved safety and mission performance through ISMS continuous improvement. The focus of ISMS improvement was safety culture improvement building on operating experience from similar industries such as the domestic and international commercial nuclear and chemical industry.

  3. The PIANC Safety Factor System for Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    2000-01-01

    The paper presents a summary of the recommendations for implementation of safety in breakwater designs given by the PIANC PTC IT Working Group No 12 on Analysis of Rubble Mound Breakwaters with Vertical and Inclined Concrete Walls. The working groups developed for the most important failure modes...... a system of partial safety factors which facilitate design to any target safety level....

  4. Safety-Critical Java for Embedded Systems

    DEFF Research Database (Denmark)

    Rios Rivas, Juan Ricardo

    Safety-critical systems are real-time systems whose failure can have severe or catastrophic consequences, possibly endangering human life. Many safety-critical systems incorporate embedded computers used to control different tasks. Software running on safety-critical systems needs to be certified...... before its deployment and the most time-consuming step of this process is the testing and verification phase. Due to the increasing complexity in safety-critical systems there is a need for new technologies that can facilitate testing and verification activities. The safety-critical specification...... for Java aims at providing a reduced set of the Java programming language that can be used for systems that need to be certified at the highest levels of criticality. Safety-critical Java (SCJ) restricts how a developer can structure an application by providing a specific programming model...

  5. Intrauterin graviditet efter Cavatermbehandling

    DEFF Research Database (Denmark)

    Shokouh-Amiri, Ali; Kjaergaard, Niels

    2009-01-01

    A case of intrauterine pregnancy occurring after successful balloon thermal endometrial ablation is described. Although rare, pregnancy after endometrial ablation is possible, and use of a supplemental contraceptive method should be planned. In case of pregnancy after endometrial ablation......, the woman should be informed of the high risk of pregnancy complications, and termination of the pregnancy should be discussed. Udgivelsesdato: 2009-Feb-16...

  6. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  7. A philosophy for space nuclear systems safety

    International Nuclear Information System (INIS)

    Marshall, A.C.

    1992-01-01

    The unique requirements and contraints of space nuclear systems require careful consideration in the development of a safety policy. The Nuclear Safety Policy Working Group (NSPWG) for the Space Exploration Initiative has proposed a hierarchical approach with safety policy at the top of the hierarchy. This policy allows safety requirements to be tailored to specific applications while still providing reassurance to regulators and the general public that the necessary measures have been taken to assure safe application of space nuclear systems. The safety policy used by the NSPWG is recommended for all space nuclear programs and missions

  8. Automation for System Safety Analysis

    Science.gov (United States)

    Malin, Jane T.; Fleming, Land; Throop, David; Thronesbery, Carroll; Flores, Joshua; Bennett, Ted; Wennberg, Paul

    2009-01-01

    This presentation describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis and simulation to identify and evaluate possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations and scenarios; and 4) identify resulting candidate scenarios for software integration testing. There has been significant technical progress in model extraction from Orion program text sources, architecture model derivation (components and connections) and documentation of extraction sources. Models have been derived from Internal Interface Requirements Documents (IIRDs) and FMEA documents. Linguistic text processing is used to extract model parts and relationships, and the Aerospace Ontology also aids automated model development from the extracted information. Visualizations of these models assist analysts in requirements overview and in checking consistency and completeness.

  9. Probabilistic safety criteria at the safety function/system level

    International Nuclear Information System (INIS)

    1989-09-01

    A Technical Committee Meeting was held in Vienna, Austria, from 26-30 January 1987. The objectives of the meeting were: to review the national developments of PSC at the level of safety functions/systems including future trends; to analyse basic principles, assumptions, and objectives; to compare numerical values and the rationale for choosing them; to compile the experience with use of such PSC; to analyse the role of uncertainties in particular regarding procedures for showing compliance. The general objective of establishing PSC at the level of safety functions/systems is to provide a pragmatic tool to evaluate plant safety which is placing emphasis on the prevention principle. Such criteria could thus lead to a better understanding of the importance to safety of the various functions which have to be performed to ensure the safety of the plant, and the engineering means of performing these functions. They would reflect the state-of-the-art in modern PSAs and could contribute to a balance in system design. This report, prepared by the participants of the meeting, reviews the current status and future trends in the field and should assist Member States in developing their national approaches. The draft of this document was also submitted to INSAG to be considered in its work to prepare a document on safety principles for nuclear power plants. Five papers presented at the meeting are also included in this publication. A separate abstract was prepared for each of these papers. Refs, figs and tabs

  10. Architecture Level Safety Analyses for Safety-Critical Systems

    Directory of Open Access Journals (Sweden)

    K. S. Kushal

    2017-01-01

    Full Text Available The dependency of complex embedded Safety-Critical Systems across Avionics and Aerospace domains on their underlying software and hardware components has gradually increased with progression in time. Such application domain systems are developed based on a complex integrated architecture, which is modular in nature. Engineering practices assured with system safety standards to manage the failure, faulty, and unsafe operational conditions are very much necessary. System safety analyses involve the analysis of complex software architecture of the system, a major aspect in leading to fatal consequences in the behaviour of Safety-Critical Systems, and provide high reliability and dependability factors during their development. In this paper, we propose an architecture fault modeling and the safety analyses approach that will aid in identifying and eliminating the design flaws. The formal foundations of SAE Architecture Analysis & Design Language (AADL augmented with the Error Model Annex (EMV are discussed. The fault propagation, failure behaviour, and the composite behaviour of the design flaws/failures are considered for architecture safety analysis. The illustration of the proposed approach is validated by implementing the Speed Control Unit of Power-Boat Autopilot (PBA system. The Error Model Annex (EMV is guided with the pattern of consideration and inclusion of probable failure scenarios and propagation of fault conditions in the Speed Control Unit of Power-Boat Autopilot (PBA. This helps in validating the system architecture with the detection of the error event in the model and its impact in the operational environment. This also provides an insight of the certification impact that these exceptional conditions pose at various criticality levels and design assurance levels and its implications in verifying and validating the designs.

  11. Intrauterine device use in an urban university clinic: safety of use in a population at high risk for sexually transmitted infections.

    Science.gov (United States)

    Drake, Robin W; Martins, Summer L; Whitaker, Amy K

    2015-10-01

    The objective was to describe infection rates after intrauterine device (IUD) placement at an urban teaching hospital that did not restrict IUD eligibility based on risk factors for sexually transmitted infections (STIs). We reviewed charts of patients undergoing IUD placement at the University of Chicago obstetrics and gynecology resident clinic from July 2007 to June 2008 (n=283). The primary outcome was diagnosis of pelvic inflammatory disease (PID) within 12 months. Almost half (49.5%) of patients reported a history of any STI. Two patients (0.7%) were diagnosed with PID. Postplacement infection in this unrestricted population was infrequent and comparable to reported rates in previous studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Anticipated pain as a predictor of discomfort with intrauterine device placement.

    Science.gov (United States)

    Dina, Blair; Peipert, Leah J; Zhao, Qiuhong; Peipert, Jeffrey F

    2018-02-01

    Intrauterine devices have been gaining popularity for the past 2 decades. Current data report that >10% of women who use contraception are using an intrauterine device. With intrauterine device is one of the most effective forms of long-acting reversible contraception, yet evidence shows that fear of pain during intrauterine device placement deters women from choosing an intrauterine device as their contraceptive method. The objective of this analysis was to estimate the association between anticipated pain with intrauterine device placement and experienced pain. We also assessed other factors associated with increased discomfort during intrauterine device placement. We hypothesized that patients with higher levels of anticipated pain would report a higher level of discomfort during placement. We performed a secondary analysis of the Contraceptive CHOICE Project. There were 9256 patients enrolled in Contraceptive CHOICE Project from the St. Louis region from 2007-2011; data for 1149 subjects who came for their first placement of either the original 52-mg levonorgestrel intrauterine system or the copper intrauterine device were analyzed in this study. Patients were asked to report their anticipated pain before intrauterine device placement and experienced pain during placement on a 10-point visual analog scale. We assessed the association of anticipated pain, patient demographics, reproductive characteristics, and intrauterine device type with experienced pain with intrauterine device placement. The mean age of Contraceptive CHOICE Project participants in this subanalysis was 26 years. Of these 1149 study subjects, 44% were black, and 53% were of low socioeconomic status. The median expected pain score was 5 for both the levonorgestrel intrauterine system and the copper intrauterine device; the median experienced pain score was 5 for the levonorgestrel intrauterine system and 4 for the copper intrauterine device. After we controlled for parity, history of

  13. 77 FR 70409 - System Safety Program

    Science.gov (United States)

    2012-11-26

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Federal Railroad Administration 49 CFR Part 270 2130-AC31 System Safety Program AGENCY: Federal Railroad... commuter and intercity passenger railroads to develop and implement a system safety program (SSP) to...

  14. Ergonomics in the context of system safety

    International Nuclear Information System (INIS)

    Donnelly, K.E.

    1984-01-01

    In a complex industrial environment, ergonomics must be combined with management science and systems analysis to produce a program which can create effective change and improve safety performance. We give an overview of such an approach, namely System Safety, so that its ergonomic content may be seen

  15. Opportunistic Sensing in Train Safety Systems

    NARCIS (Netherlands)

    Scholten, Johan; Bakker, Pascal

    2011-01-01

    Train safety systems are complex and expensive, and changing them requires huge investments. Changes are evolutionary and small. Current developments, like faster - high speed - trains and a higher train density on the railway network, have initiated research on safety systems that can cope with the

  16. Systems Thinking and Patient Safety

    National Research Council Canada - National Science Library

    Schyve, Paul M

    2005-01-01

    Patient safety is a prominent theme in health care delivery today. This should come as no surprise, given that "first, do no harm" has been the ethical watchword throughout the history of medicine, nursing, and pharmacy...

  17. Computer system reliability safety and usability

    CERN Document Server

    Dhillon, BS

    2013-01-01

    Computer systems have become an important element of the world economy, with billions of dollars spent each year on development, manufacture, operation, and maintenance. Combining coverage of computer system reliability, safety, usability, and other related topics into a single volume, Computer System Reliability: Safety and Usability eliminates the need to consult many different and diverse sources in the hunt for the information required to design better computer systems.After presenting introductory aspects of computer system reliability such as safety, usability-related facts and figures,

  18. Recommendations for the LHC safety alarm system

    CERN Document Server

    Laeger, H

    1999-01-01

    A working group was set up to define the LHC safety alarm system, also known as Alarm-of-Level-3-System (AL3S). The mandate asked for recommendations to be elaborated on four items: the overall concept of the AL3S for machine and experiments, the transmission and display of safety alarms, the AL3S during civil engineering construction, and the transition from the present LEP to the final LHC safety alarm system. The members of the working group represented a wide range of interest and experience including the CERN Fire Brigade, safety officers from experiments and machines, and specialists for safety and control systems. The recommendations highlight the need for a clear definition of responsibilities and procedures, well-engineered homogeneous systems across CERN, and they point to several important issues outside the mandate of the working group. These recommendations were presented, discussed and accepted by several CERN and LHC committees.

  19. Intrauterine Contraceptive Device Discontinuation Among Women in ...

    African Journals Online (AJOL)

    In conclusion, more effort should be directed to counseling for adherence to the IUD use to ensure longer duration of use. Provision of the levonorgestrel intrauterine system which reduces bleeding and dysmenorrhoea, in our clinic may increase the continuation rate of IUD. Key words; IUD, duration of use, discontinuation, ...

  20. Parasphaerolaimus magdolnae sp. n. (Nematoda, Sphaerolaimidae) with intra-uterine development of its offspring from a Brazilian estuarine system.

    Science.gov (United States)

    Cavalcanti, Mariana DA Fonseca; Venekey, Virag

    2017-11-29

    One new species of Parasphaerolaimus is described from a Brazilian estuarine system with intra-uterine development of its offspring. Parasphaerolaimus magdolnae sp. n. is distinguished from other species of the genus by the presence of only one anterior testis, spicules morphology and size and a gubernaculum without dorsal apophysis. The cuticle of the new species is striated and the position of the vulva is far posterior on the body, almost reaching the anus. The taxonomy of Parasphaerolaimus was also re-examined and two other species were transferred from Sphaerolaimus to Parasphaerolaimus after the last revision: P. pentasetus (Pastor de Ward, 1984) comb. n. and P. striatus (Allgén, 1935) comb. n. An updated identification key for all valid species of Parasphaerolaimus is included.

  1. Safety-critical Java for embedded systems

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Dalsgaard, Andreas Engelbredt; Hansen, René Rydhof

    2016-01-01

    This paper presents the motivation for and outcomes of an engineering research project on certifiable Javafor embedded systems. The project supports the upcoming standard for safety-critical Java, which defines asubset of Java and libraries aiming for development of high criticality systems....... The outcome of this projectinclude prototype safety-critical Java implementations, a time-predictable Java processor, analysis tools formemory safety, and example applications to explore the usability of safety-critical Java for this applicationarea. The text summarizes developments and key contributions...

  2. Operation safety of complex industrial systems

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    1999-01-01

    Zero fault or zero risk is an unreachable goal in industrial activities like nuclear activities. However, methods and techniques exist to reduce the risks to the lowest possible and acceptable level. The operation safety consists in the recognition, evaluation, prediction, measurement and mastery of technological and human faults. This paper analyses each of these points successively: 1 - evolution of operation safety; 2 - definitions and basic concepts: failure, missions and functions of a system and of its components, basic concepts and operation safety; 3 - forecasting analysis of operation safety: reliability data, data-banks, precautions for the use of experience feedback data; realization of an operation safety study: management of operation safety, quality assurance, critical review and audit of operation safety studies; 6 - conclusions. (J.S.)

  3. Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A.

    Science.gov (United States)

    Rowe, Patrick; Farley, Tim; Peregoudov, Alexandre; Piaggio, Gilda; Boccard, Simone; Landoulsi, Sihem; Meirik, Olav

    2016-06-01

    To compare rates of unintended pregnancy, method continuation and reasons for removal among women using the 52-mg levonorgestrel (daily release 20 microg) levonorgestrel IUD (LNG-IUD) or the copper T 380A (TCu380A) intrauterine device. This was an open-label 7-year randomized controlled trial in 20 centres, 11 of which in China. Data on 1884 women with interval insertion of the LNG-IUD and 1871 of the TCu380A were analysed using life tables with 30-day intervals and Cox proportional hazards models. The cumulative 7-year pregnancy rate of the LNG-IUD was 0.5 (standard error 0.2) per 100, significantly lower than 2.5 (0.4) per 100 of the TCu380A, cumulative method discontinuation rates at 7 years were 70.6 (1.2) and 40.8 (1.3) per 100, respectively. Dominant reasons for discontinuing the LNG-IUD were amenorrhea (26.1 [1.3] per 100) and reduced bleeding (12.5 [1.1] per 100), particularly in Chinese women and, for the TCu380A, increased bleeding (9.9 [0.9] per 100), especially among non-Chinese women. Removal rates for pain were similar for the two intrauterine devices (IUDs). Cumulative rates of removal for symptoms compatible with hormonal side effects were 5.7 (0.7) and 0.4 (0.2) per 100 for the LNG-IUD and TCu380A, respectively, and cumulative losses to follow-up at 7 years were 26.0 (1.4) and 36.9 (1.3) per 100, respectively. The LNG-IUD and the TCu380A have very high contraceptive efficacy, with the LNG-IUD significantly higher than the TCu380A. Overall rates of IUD removals were higher among LNG-IUD users than TCu380A users. Removals for amenorrhea appeared culturally associated. The 52-mg LNG-IUD and the TCu380A have very high contraceptive efficacy through 7 years. As an IUD, the unique side effects of the LNG-IUD are reduced bleeding, amenorrhea and symptoms compatible with hormonal contraceptives. Copyright © 2016. Published by Elsevier Inc.

  4. OBTAINING FOOD SAFETY BY APPLYING HACCP SYSTEM

    Directory of Open Access Journals (Sweden)

    ION CRIVEANU

    2012-01-01

    Full Text Available In order to increase the confidence of the trading partners and consumers in the products which are sold on the market, enterprises producing food are required to implement the food safety system HACCP,a particularly useful system because the manufacturer is not able to fully control finished products . SR EN ISO 22000:2005 establishes requirements for a food safety management system where an organization in the food chain needs to proove its ability to control food safety hazards in order to ensure that food is safe at the time of human consumption. This paper presents the main steps which ensure food safety using the HACCP system, and SR EN ISO 20000:2005 requirements for food safety.

  5. Glucocorticoid programming of intrauterine development.

    Science.gov (United States)

    Fowden, A L; Valenzuela, O A; Vaughan, O R; Jellyman, J K; Forhead, A J

    2016-07-01

    Glucocorticoids (GCs) are important environmental and maturational signals during intrauterine development. Toward term, the maturational rise in fetal glucocorticoid receptor concentrations decreases fetal growth and induces differentiation of key tissues essential for neonatal survival. When cortisol levels rise earlier in gestation as a result of suboptimal conditions for fetal growth, the switch from tissue accretion to differentiation is initiated prematurely, which alters the phenotype that develops from the genotype inherited at conception. Although this improves the chances of survival should delivery occur, it also has functional consequences for the offspring long after birth. Glucocorticoids are, therefore, also programming signals that permanently alter tissue structure and function during intrauterine development to optimize offspring fitness. However, if the postnatal environmental conditions differ from those signaled in utero, the phenotypical outcome of early-life glucocorticoid receptor overexposure may become maladaptive and lead to physiological dysfunction in the adult. This review focuses on the role of GCs in developmental programming, primarily in farm species. It examines the factors influencing GC bioavailability in utero and the effects that GCs have on the development of fetal tissues and organ systems, both at term and earlier in gestation. It also discusses the windows of susceptibility to GC overexposure in early life together with the molecular mechanisms and long-term consequences of GC programming with particular emphasis on the cardiovascular, metabolic, and endocrine phenotype of the offspring. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Automated process safety parameters monitoring system

    International Nuclear Information System (INIS)

    Iyudina, O.S.; Solov'eva, A.G.; Syrov, A.A.

    2015-01-01

    Basing on the expertise in upgrading and creation of control systems for NPP process equipment, “Diakont” has developed the automated process safety parameters monitoring system project. The monitoring system is a set of hardware, software and data analysis tools based on a dynamic logical-and-probabilistic model of process safety. The proposed monitoring system can be used for safety monitoring and analysis of the following processes: reactor core reloading; spent nuclear fuel transfer; startup, loading, on-load operation and shutdown of an NPP turbine [ru

  7. System safety management: A new discipline

    Science.gov (United States)

    Pope, W. C.

    1971-01-01

    The systems theory is discussed in relation to safety management. It is suggested that systems safety management, as a new discipline, holds great promise for reducing operating errors, conserving labor resources, avoiding operating costs due to mistakes, and for improving managerial techniques. It is pointed out that managerial failures or system breakdowns are the basic reasons for human errors and condition defects. In this respect, a recommendation is made that safety engineers stop visualizing the problem only with the individual (supervisor or employee) and see the problem from the systems point of view.

  8. Safety features of subcritical fluid fueled systems

    Energy Technology Data Exchange (ETDEWEB)

    Bell, C.R. [Los Alamos National Laboratory, NM (United States)

    1995-10-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved is very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible.

  9. Safety features of subcritical fluid fueled systems

    International Nuclear Information System (INIS)

    Bell, Charles R.

    1995-01-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved is very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible

  10. Safety features of subcritical fluid fueled systems

    International Nuclear Information System (INIS)

    Bell, C.R.

    1994-01-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved in very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible

  11. New developments in intrauterine device use: focus on the US

    Directory of Open Access Journals (Sweden)

    Nelson AL

    2016-09-01

    Full Text Available Anita L Nelson,1 Natasha Massoudi2 1Department of Obstetrics and Gynecology, Los Angeles BioMedical Research Institute at Harbor-UCLA Medical Center, David Geffen School of Medicine at UCLA, Torrance, CA, USA; 2American University of the Caribbean School of Medicine, Cupecoy, Sint Maarten Abstract: Many more women in the US today rely upon intrauterine devices (IUDs than in the past. This increased utilization may have substantially contributed to the decline in the percentage of unintended pregnancies in the US. Evidence-based practices have increased the number of women who are medically eligible for IUDs and have enabled more rapid access to the methods. Many women enjoy freedom to use IUDs without cost, but for many the impact of the Affordable Care Act has yet to be realized. Currently, there are three hormonal IUDs and one copper IUD available in the US. Each IUD is extremely effective, convenient, and safe. The newer IUDs have been tested in populations not usually included in clinical trials and provide reassuring answers to older concerns about IUD use in these women, including information about expulsion, infection, and discontinuation. On the other hand, larger surveillance studies have provided new estimates about the risks of complications such as perforation, especially in postpartum and breastfeeding women. This article summarizes significant features of each IUD and provides a summary of the differences to aid clinicians in the US and other countries in advising women about IUD choices. Keywords: copper intrauterine device, levonorgestrel intrauterine systems, noncontraceptive benefits, same-day/quick start initiation, safety, bleeding patterns, placement pain, medical eligibility

  12. Safety management system needs assessment.

    Science.gov (United States)

    2016-04-01

    The safety of the traveling public is critical as each year there are approximately 200 highway fatalities in Nebraska and numerous crash injuries. The objective of this research was to conduct a needs assessment to identify the requirements of a sta...

  13. Safety standards of IAEA for management systems

    International Nuclear Information System (INIS)

    Vincze, P.

    2005-01-01

    IAEA has developed a new series of safety standards which are assigned for constitution of the conditions and which give the instruction for setting up the management systems that integrate the aims of safety, health, life environment and quality. The new standard shall replace IAEA 50-C-Q - Requirements for security of the quality for safety in nuclear power plants and other nuclear facilities as well as 14 related safety instructions mentioned in the Safety series No. 50-C/SG-Q (1996). When developing of this complex, integrated set of requirements for management systems, the IAEA requirements 50-C-Q (1996) were taken into consideration as well as the publications developed within the International organisation for standardization (ISO) ISO 9001:2000 and ISO14001: 1996. The experience of European Union member states during the development, implementation and improvement of the management systems were also taken into consideration

  14. NASA Aviation Safety Reporting System (ASRS)

    Science.gov (United States)

    Connell, Linda J.

    2017-01-01

    The NASA Aviation Safety Reporting System (ASRS) collects, analyzes, and distributes de-identified safety information provided through confidentially submitted reports from frontline aviation personnel. Since its inception in 1976, the ASRS has collected over 1.4 million reports and has never breached the identity of the people sharing their information about events or safety issues. From this volume of data, the ASRS has released over 6,000 aviation safety alerts concerning potential hazards and safety concerns. The ASRS processes these reports, evaluates the information, and provides selected de-identified report information through the online ASRS Database at http:asrs.arc.nasa.gov. The NASA ASRS is also a founding member of the International Confidential Aviation Safety Systems (ICASS) group which is a collection of other national aviation reporting systems throughout the world. The ASRS model has also been replicated for application to improving safety in railroad, medical, fire fighting, and other domains. This presentation will discuss confidential, voluntary, and non-punitive reporting systems and their advantages in providing information for safety improvements.

  15. Prestandardisation Activities for Computer Based Safety Systems

    DEFF Research Database (Denmark)

    Taylor, J. R.; Bologna, S.; Ehrenberger, W.

    1981-01-01

    Questions of technical safety become more and more important. Due to the higher complexity of their functions computer based safety systems have special problems. Researchers, producers, licensing personnel and customers have met on a European basis to exchange knowledge and formulate positions...

  16. LOFT integral test system final safety analysis report

    International Nuclear Information System (INIS)

    1974-03-01

    Safety analyses are presented for the following LOFT Reactor systems: engineering safety features; support buildings and facilities; instrumentation and controls; electrical systems; and auxiliary systems. (JWR)

  17. Safety status system for operating room devices.

    Science.gov (United States)

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  18. Safety considerations for compressed hydrogen storage systems

    International Nuclear Information System (INIS)

    Gleason, D.

    2006-01-01

    An overview of the safety considerations for various hydrogen storage options, including stationary, vehicle storage, and mobile refueling technologies. Indications of some of the challenges facing the industry as the demand for hydrogen fuel storage systems increases. (author)

  19. CDC STATE System Tobacco Legislation - Fire Safety

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1995-2017. Centers for Disease Control and Prevention (CDC). State Tobacco Activities Tracking and Evaluation (STATE) System. Legislation – Fire-Safety. The STATE...

  20. CDC STATE System Tobacco Legislation - Fire Safety

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1995-2018. Centers for Disease Control and Prevention (CDC). State Tobacco Activities Tracking and Evaluation (STATE) System. Legislation – Fire-Safety. The STATE...

  1. Proactive Management of Aviation System Safety Risk

    Data.gov (United States)

    National Aeronautics and Space Administration — Aviation safety systems have undergone dramatic changes over the past fifty years. If you take a look at the early technology in this area, you'll see that there was...

  2. Safety Justification and Safety Case for Safety-critical Software in Digital Reactor Protection System

    International Nuclear Information System (INIS)

    Kwon, Kee-Choon; Lee, Jang-Soo; Jee, Eunkyoung

    2016-01-01

    Nuclear safety-critical software is under strict regulatory requirements and these regulatory requirements are essential for ensuring the safety of nuclear power plants. The verification & validation (V and V) and hazard analysis of the safety-critical software are required to follow regulatory requirements through the entire software life cycle. In order to obtain a license from the regulatory body through the development and validation of safety-critical software, it is essential to meet the standards which are required by the regulatory body throughout the software development process. Generally, large amounts of documents, which demonstrate safety justification including standard compliance, V and V, hazard analysis, and vulnerability assessment activities, are submitted to the regulatory body during the licensing process. It is not easy to accurately read and evaluate the whole documentation for the development activities, implementation technology, and validation activities. The safety case methodology has been kwon a promising approach to evaluate the level and depth of the development and validation results. A safety case is a structured argument, supported by a body of evidence that provides a compelling, comprehensible, and valid case that a system is safe for a given application in a given operating environment. It is suggested to evaluate the level and depth of the results of development and validation by applying safety case methodology to achieve software safety demonstration. A lot of documents provided as evidence are connected to claim that corresponds to the topic for safety demonstration. We demonstrated a case study in which more systematic safety demonstration for the target system software is performed via safety case construction than simply listing the documents

  3. Levonorgestrel-releasing intrauterine system vs. usual medical treatment for menorrhagia: an economic evaluation alongside a randomised controlled trial.

    Directory of Open Access Journals (Sweden)

    Sabina Sanghera

    Full Text Available OBJECTIVE: To undertake an economic evaluation alongside the largest randomised controlled trial comparing Levonorgestrel-releasing intrauterine device ('LNG-IUS' and usual medical treatment for women with menorrhagia in primary care; and compare the cost-effectiveness findings using two alternative measures of quality of life. METHODS: 571 women with menorrhagia from 63 UK centres were randomised between February 2005 and July 2009. Women were randomised to having a LNG-IUS fitted, or usual medical treatment, after discussing with their general practitioner their contraceptive needs or desire to avoid hormonal treatment. The treatment was specified prior to randomisation. For the economic evaluation we developed a state transition (Markov model with a 24 month follow-up. The model structure was informed by the trial women's pathway and clinical experts. The economic evaluation adopted a UK National Health Service perspective and was based on an outcome of incremental cost per Quality Adjusted Life Year (QALY estimated using both EQ-5D and SF-6D. RESULTS: Using EQ-5D, LNG-IUS was the most cost-effective treatment for menorrhagia. LNG-IUS costs £100 more than usual medical treatment but generated 0.07 more QALYs. The incremental cost-effectiveness ratio for LNG-IUS compared to usual medical treatment was £1600 per additional QALY. Using SF-6D, usual medical treatment was the most cost-effective treatment. Usual medical treatment was both less costly (£100 and generated 0.002 more QALYs. CONCLUSION: Impact on quality of life is the primary indicator of treatment success in menorrhagia. However, the most cost-effective treatment differs depending on the quality of life measure used to estimate the QALY. Under UK guidelines LNG-IUS would be the recommended treatment for menorrhagia. This study demonstrates that the appropriate valuation of outcomes in menorrhagia is crucial.

  4. Chinese experience with intrauterine devices.

    Science.gov (United States)

    Bilian, Xiao

    2007-06-01

    Changes in the use of intrauterine devices (IUDs) for contraception in China in the past 10 years are reviewed. Replacement of the inert stainless steel ring with copper-bearing IUDs was an essential decision to improve the efficacy of the IUDs. The most commonly used, TCu380A, TCu220C and MLCu375, and those developed in China, such as the uterine-shaped UCu300 IUD and gamma Cu380 IUD, are reviewed. Studies of MLCu375 and TCu380A for emergency contraception revealed a highly effective method, which could prevent over 96% of unwanted pregnancies. Use of levonorgestrel-releasing system provides both contraceptive and therapeutic effects in the treatment of menorrhagia.

  5. Design of an Active Automotive Safety System

    Directory of Open Access Journals (Sweden)

    Y. Wang

    2013-07-01

    Full Text Available With the development of the national economy, the people's standard of living got corresponding improvement, cars has been one of the indispensable traffic tools in many families. An active safety system is proposed, which can real-time detect the vehicle's running status and judge the security status of the vehicle. The system, which takes single-chip microcomputer as the controlling core and combines with millimeter-wave and ultrasonic distance measurement technology, can detect the distance from vehicle to vehicle and judge the security status of the vehicle. The hardware composition of the system and the data acquiring circuit are proposed, the mathematic model for different situation is established, and the controlling algorithm is completed. This system can accurately measure speed and distance between vehicles; the active safety control system can meet the relevant data measurement and transmission requirement; and can meet the functional requirement of the active safety control system

  6. Strategy to safety grade systems replacements

    International Nuclear Information System (INIS)

    Stimler, M.; Sullivan, K.E.; Trebincevic, I.

    1993-01-01

    The introduction of digital instrumentation and control systems in nuclear power plants is characterized by the need to satisfy the requirements of safety, reliability and man-machine ergonomics. Today digital instrumentation and control systems meet these requirements and the trend in Europe is towards full digital based nuclear power plant control systems. This paper describes Siemens (KWU) experience in nuclear power plants and development in trends within Europe. Topics which are the subject of major concern to NPP operators addressed in this paper are: human performance factors - man-machine interface; operating philosophy; safety, availability and reliability. Other aspects addressed are: Siemens open-quotes defense in depthclose quotes concept, description of Siemens digital I ampersand C systems, safety requirements and systems, I ampersand C qualification, control room ergonomics, information systems and retrofitting experience

  7. Safety systems (AL3) and systems relevant to Safety

    CERN Document Server

    Hutchins, S

    2009-01-01

    The AL3 systems are basic life protection and are especially important during the shutdown; there should be no point in the LHC underground areas in which a person is not or cannot be informed of the dangers around him when they exist and so take appropriate action. The implantation of the different detection and alarm systems will be reviewed and their performance and reliability examined. The need for fire doors to control released Helium will also be considered, which may have consequences for the ventilation and access systems.

  8. K West integrated water treatment system subproject safety analysis document

    International Nuclear Information System (INIS)

    SEMMENS, L.S.

    1999-01-01

    This Accident Analysis evaluates unmitigated accident scenarios, and identifies Safety Significant and Safety Class structures, systems, and components for the K West Integrated Water Treatment System

  9. Classification of Aeronautics System Health and Safety Documents

    Data.gov (United States)

    National Aeronautics and Space Administration — Most complex aerospace systems have many text reports on safety, maintenance, and associated issues. The Aviation Safety Reporting System (ASRS) spans several...

  10. K West integrated water treatment system subproject safety analysis document

    Energy Technology Data Exchange (ETDEWEB)

    SEMMENS, L.S.

    1999-02-24

    This Accident Analysis evaluates unmitigated accident scenarios, and identifies Safety Significant and Safety Class structures, systems, and components for the K West Integrated Water Treatment System.

  11. System Safety in an IT Service Organization

    Science.gov (United States)

    Parsons, Mike; Scutt, Simon

    Within Logica UK, over 30 IT service projects are considered safetyrelated. These include operational IT services for airports, railway infrastructure asset management, nationwide radiation monitoring and hospital medical records services. A recent internal audit examined the processes and documents used to manage system safety on these services and made a series of recommendations for improvement. This paper looks at the changes and the challenges to introducing them, especially where the service is provided by multiple units supporting both safety and non-safety related services from multiple locations around the world. The recommendations include improvements to service agreements, improved process definitions, routine safety assessment of changes, enhanced call logging, improved staff competency and training, and increased safety awareness. Progress is reported as of today, together with a road map for implementation of the improvements to the service safety management system. A proposal for service assurance levels (SALs) is discussed as a way forward to cover the wide variety of services and associated safety risks.

  12. Upgrading safety systems of industrial irradiation facilities

    International Nuclear Information System (INIS)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L.; Thomé, Z.D.

    2017-01-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  13. Upgrading safety systems of industrial irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L., E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br, E-mail: mara@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  14. Understanding Nuclear Safety Culture: A Systemic Approach

    International Nuclear Information System (INIS)

    Afghan, A.N.

    2016-01-01

    The Fukushima accident was a systemic failure (Report by Director General IAEA on the Fukushima Daiichi Accident). Systemic failure is a failure at system level unlike the currently understood notion which regards it as the failure of component and equipment. Systemic failures are due to the interdependence, complexity and unpredictability within systems and that is why these systems are called complex adaptive systems (CAS), in which “attractors” play an important role. If we want to understand the systemic failures we need to understand CAS and the role of these attractors. The intent of this paper is to identify some typical attractors (including stakeholders) and their role within complex adaptive system. Attractors can be stakeholders, individuals, processes, rules and regulations, SOPs etc., towards which other agents and individuals are attracted. This paper will try to identify attractors in nuclear safety culture and influence of their assumptions on safety culture behavior by taking examples from nuclear industry in Pakistan. For example, if the nuclear regulator is an attractor within nuclear safety culture CAS then how basic assumptions of nuclear plant operators and shift in-charges about “regulator” affect their own safety behavior?

  15. Safety parameter display system for Kalinin NPP

    International Nuclear Information System (INIS)

    Andreev, V.I.; Videneev, E.N.; Tissot, J.C.; Joonekindt, D.; Davidenko, N.N.; Shaftan, G.I.; Dounaev, V.G.; Neboyan, V.T.

    1995-01-01

    The paper discusses the safety parameter display system (SPDS), which is being designed for Kalinin NPP. The assessment of the safety status of the plant is done by the continuous monitoring of six critical safety functions and the corresponding status trees. Besides, a number of additional functions are realized within the scope of KlnNPP, aimed at providing the operator and the safety engineer in the main control room with more detailed information in accidental situation as well as during the normal operation. In particular, these functions are: archiving, data logs and alarm handling, safety actions monitoring, mnemonic diagrams indicating the state of main technological equipment and basic plant parameters, reference data, etc. As compared with the traditional scope of functions of this kind of systems, the functionality of KlnNPP SPDS is significantly expanded due to the inclusion in it the operator support function ''computerized procedures''. The basic SPDS implementation platform is ADACS of SEMA GROUP design. The system architecture includes two workstations in the main control room: one is for reactor operator and the other one for safety engineer. Every station has two CRT screens which ensures computerized procedures implementation and provides for extra services for the operator. Also, the information from the SPDS is transmitted to the local crisis center and to the crisis center of the State utility organization concern ''Rosenergoatom''. (author). 3 refs, 6 figs, 1 tab

  16. Food safety performance indicators to benchmark food safety output of food safety management systems.

    Science.gov (United States)

    Jacxsens, L; Uyttendaele, M; Devlieghere, F; Rovira, J; Gomez, S Oses; Luning, P A

    2010-07-31

    There is a need to measure the food safety performance in the agri-food chain without performing actual microbiological analysis. A food safety performance diagnosis, based on seven indicators and corresponding assessment grids have been developed and validated in nine European food businesses. Validation was conducted on the basis of an extensive microbiological assessment scheme (MAS). The assumption behind the food safety performance diagnosis is that food businesses which evaluate the performance of their food safety management system in a more structured way and according to very strict and specific criteria will have a better insight in their actual microbiological food safety performance, because food safety problems will be more systematically detected. The diagnosis can be a useful tool to have a first indication about the microbiological performance of a food safety management system present in a food business. Moreover, the diagnosis can be used in quantitative studies to get insight in the effect of interventions on sector or governmental level. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Integrated safety management system verification: Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, R.F.

    1998-08-10

    Department of Energy (DOE) Policy (P) 450.4, Safety Management System Policy, commits to institutionalization of an Integrated Safety Management System (ISMS) throughout the DOE complex. The DOE Acquisition Regulations (DEAR, 48 CFR 970) requires contractors to manage and perform work in accordance with a documented Integrated Safety Management System (ISMS). Guidance and expectations have been provided to PNNL by incorporation into the operating contract (Contract DE-ACM-76FL0 1830) and by letter. The contract requires that the contractor submit a description of their ISMS for approval by DOE. PNNL submitted their proposed Safety Management System Description for approval on November 25,1997. RL tentatively approved acceptance of the description pursuant to a favorable recommendation from this review. The Integrated Safety Management System Verification is a review of the adequacy of the ISMS description in fulfilling the requirements of the DEAR and the DOE Policy. The purpose of this review is to provide the Richland Operations Office Manager with a recommendation for approval of the ISMS description of the Pacific Northwest Laboratory based upon compliance with the requirements of 49 CFR 970.5204(-2 and -78); and to verify the extent and maturity of ISMS implementation within the Laboratory. Further the review will provide a model for other DOE laboratories managed by the Office of Assistant Secretary for Energy Research.

  18. Expert systems and nuclear safety

    International Nuclear Information System (INIS)

    Beltracchi, L.

    1990-01-01

    The US Nuclear Regulatory Commission (NRC) and the Electric Power Research Institute have initiated a broad-based exploration of means to evaluate the potential applications of expert systems in the nuclear industry. This exploratory effort will assess the use of expert systems to augment the diagnostic and decision-making capabilities of personnel with the goal of enhancing productivity, reliability, and performance. The initial research effort is the development and documentation of guidelines for verifying and validating (V and V) expert systems. An initial application of expert systems in the nuclear industry is to aid operations and maintenance personnel in decision-making tasks. The scope of the decision aiding covers all types of cognitive behavior consisting of skill, rule, and knowledge-based behavior. For example, procedure trackers were designed and tested to support rule-based behavior. Further, these systems automate many of the tedious, error-prone human monitoring tasks, thereby reducing the potential for human error. The paper version of the procedure contains the knowledge base and the rules and thus serves as the basis of the design verification of the procedure tracker. Person-in-the-loop tests serve as the basis for the validation of a procedure tracker. When conducting validation tests, it is important to ascertain that the human retains the locus of control in the use of the expert system

  19. Safety analysis of accident localization system

    International Nuclear Information System (INIS)

    1999-01-01

    A complex safety analysis of accident localization system of Ignalina NPP was performed. Calculation results obtained, results of non-destruct ing testing and experimental data of reinforced concrete testing of buildings does not revealed deficiencies of buildings of accident localization system at unit 1 of Ignalina NPP. Calculations were performed using codes NEPTUNE, ALGOR, CONTAIN

  20. Traffic safety effects of navigation systems

    NARCIS (Netherlands)

    Feenstra, P.J.; Hogema, J.H.; Vonk, T.

    2007-01-01

    Abstract— To investigate effects of navigation systems on traffic safety, a literature search, a damages database analysis, a user survey and an instrumented car study were conducted. This paper presents the instrumented car study to investigate the effects of a navigation system on driving behavior

  1. Safety parameter display system: an operator support system for enhancement of safety in Indian PHWRs

    International Nuclear Information System (INIS)

    Subramaniam, K.; Biswas, T.

    1994-01-01

    Ensuring operational safety in nuclear power plants is important as operator errors are observed to contribute significantly to the occurrence of accidents. Computerized operator support systems, which process and structure information, can help operators during both normal and transient conditions, and thereby enhance safety and aid effective response to emergency conditions. An important operator aid being developed and described in this paper, is the safety parameter display system (SPDS). The SPDS is an event-independent, symptom-based operator aid for safety monitoring. Knowledge-based systems can provide operators with an improved quality of information. An information processing model of a knowledge based operator support system (KBOSS) developed for emergency conditions using an expert system shell is also presented. The paper concludes with a discussion of the design issues involved in the use of a knowledge based systems for real time safety monitoring and fault diagnosis. (author). 8 refs., 4 figs., 1 tab

  2. Recent advances in systems safety and security

    CERN Document Server

    Stamatescu, Grigore

    2016-01-01

    This book represents a timely overview of advances in systems safety and security, based on selected, revised and extended contributions from the 2nd and 3rd editions of the International Workshop on Systems Safety and Security – IWSSS, held in 2014 and 2015, respectively, in Bucharest, Romania. It includes 14 chapters, co-authored by 34 researchers from 7 countries. The book provides an useful reference from both theoretical and applied perspectives in what concerns recent progress in this area of critical interest. Contributions, broadly grouped by core topic, address challenges related to information theoretic methods for assuring systems safety and security, cloud-based solutions, image processing approaches, distributed sensor networks and legal or risk analysis viewpoints. These are mostly accompanied by associated case studies providing additional practical value and underlying the broad relevance and impact of the field.

  3. Comprehensive Safety Analysis 2010 Safety Measurement System (SMS) Methodology, Version 2.1 Revised December 2010

    Science.gov (United States)

    2010-12-01

    This report documents the Safety Measurement System (SMS) methodology developed to support the Comprehensive Safety Analysis 2010 (CSA 2010) Initiative for the Federal Motor Carrier Safety Administration (FMCSA). The SMS is one of the major tools for...

  4. Long-term risk of reproductive cancer among Vietnamese women using the quinacrine hydrochloride pellet system vs. intrauterine devices or tubal ligation for contraception.

    Science.gov (United States)

    Jones, Judith K; Tave, Arlene; Pezzullo, John C; Kardia, Sharon; Lippes, Jack

    2017-04-01

    To determine the long-term risk of reproductive tract cancer in women using the quinacrine hydrochloride pellet system of permanent contraception (QS) relative to the comparable risk in women using Copper T intrauterine device (IUD) or tubal ligation surgery (TL) for long-term or permanent contraception. This was a retrospective cohort study, conducted in the Northern Vietnamese provinces of Ha Nam, Nam Dinh, Ninh Binh and Thai Binh. Women who had their first QS procedure, last IUD insertion or TL between 1989 and 1996 were interviewed regarding post-procedure health outcomes, particularly reproductive tract cancers. A 95% response rate resulted in 21,040 completed interviews. Reproductive cancer incidence rates were very low (5.77/100,000 women years of follow-up time; 95%CI = 3.72-8.94). No significant excess hazard of reproductive tract cancer was associated with QS. No significant excess long-term risk of reproductive tract cancer was found after an average 16 years of follow-up among a large group of women using QS vs. IUD/TL for contraception.

  5. Intravesical migration of an intrauterine device

    OpenAIRE

    Gyasi-Sarpong, Christian Kofi; Maison, Patrick Opoku Manu; Morhe, Emmanuel; Aboah, Ken; Appiah, Kwaku Addai-Arhin; Azorliade, Roland; Baah-Nyamekye, Kofi; Otu-Boateng, Kwaku; Amoah, George; Antwi, Isaac; Frimpong-Twumasi, Benjamin; Arthur, Douglas

    2016-01-01

    Background Intrauterine contraceptive device is the most common method of reversible contraception in women. The intrauterine contraceptive device can perforate the uterus and can also migrate into pelvic or abdominal organs. Perforation of the urinary bladder by an intrauterine contraceptive device is not common. In West Africa, intravesical migration of an intrauterine contraceptive device has been rarely reported. In this report, we present a case of an intrauterine contraceptive device mi...

  6. Modelling safety of multistate systems with ageing components

    Science.gov (United States)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna

    2016-06-01

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics of the consecutive "m out of n: F" is presented as well.

  7. Reliability assessment of redundant safety systems with degradation

    NARCIS (Netherlands)

    Rogova, E.S.

    2017-01-01

    Reliability of transport equipment plays a crucial role in providing safety for passengers. Safety systems of transport equipment perform safety functions with assigned safety integrity levels (SIL). If the reliability of a safety system is not sufficient, it has to be improved till the required

  8. Prestandardisation Activities for Computer Based Safety Systems

    DEFF Research Database (Denmark)

    Taylor, J. R.; Bologna, S.; Ehrenberger, W.

    1981-01-01

    Questions of technical safety become more and more important. Due to the higher complexity of their functions computer based safety systems have special problems. Researchers, producers, licensing personnel and customers have met on a European basis to exchange knowledge and formulate positions....... The Commission of the european Community supports the work. Major topics comprise hardware configuration and self supervision, software design, verification and testing, documentation, system specification and concurrent processing. Preliminary results have been used for the draft of an IEC standard and for some...

  9. Safety of high speed magnetic levitation transportation systems. Preliminary safety review of the transrapid maglev system

    Science.gov (United States)

    Dorer, R. M.; Hathaway, W. T.

    1990-11-01

    The safety of various magnetically levitated trains under development for possible implementation in the United States is of direct concern to the Federal Railroad Administration. Safety issues are addressed related to a specific maglev technology. The Transrapid maglev system was under development by the German Government over the last 10 to 15 years and was evolved into the current system with the TR-07 vehicle. A technically based safety review was under way over the last year by the U.S. Department of Transportation. The initial results of the review are presented to identify and assess potential maglev safety issues.

  10. Plant air systems safety study: Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    1982-05-01

    The Portsmouth Gaseous Diffusion Plant Air System facilities and operations are reviewed for potential safety problems not covered by standard industrial safety procedures. Information is presented under the following section headings: facility and process description (general); air plant equipment; air distribution system; safety systems; accident analysis; plant air system safety overview; and conclusion

  11. ANTENATAL PROGNOSIS OF INTRAUTERINE INFECTIONS

    Directory of Open Access Journals (Sweden)

    Людмила Владимировна Ренге

    2016-12-01

    Conclusion. Taking into account the clinical and immunological predictors the integrated approach allows us to estimate the risk of intrauterine infection and the risk of complications during the neonatal period with a probability of 90 %.

  12. Integrated safety management system verification: Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, R.F.

    1998-08-12

    Department of Energy (DOE) Policy (P) 450.4, Safety Management System Policy, commits to institutionalizing an Integrated Safety Management System (ISMS) throughout the DOE complex. The DOE Acquisition Regulations (DEAR 48 CFR 970) requires contractors to manage and perform work in accordance with a documented Integrated Safety Management System. The Manager, Richland Operations Office (RL), initiated a combined Phase 1 and Phase 2 Integrated Safety Management Verification review to confirm that PNNL had successfully submitted a description of their ISMS and had implemented ISMS within the laboratory facilities and processes. A combined review was directed by the Manager, RL, based upon the progress PNNL had made in the implementation of ISM. This report documents the results of the review conducted to verify: (1) that the PNNL integrated safety management system description and enabling documents and processes conform to the guidance provided by the Manager, RL; (2) that corporate policy is implemented by line managers; (3) that PNNL has provided tailored direction to the facility management; and (4) the Manager, RL, has documented processes that integrate their safety activities and oversight with those of PNNL. The general conduct of the review was consistent with the direction provided by the Under Secretary`s Draft Safety Management System Review and Approval Protocol. The purpose of this review was to provide the Manager, RL, with a recommendation to the adequacy of the ISMS description of the Pacific Northwest Laboratory based upon compliance with the requirements of 49 CFR 970.5204(-2 and -78); and, to provide an evaluation of the extent and maturity of ISMS implementation within the Laboratory. Further, this review was intended to provide a model for other DOE Laboratories. In an effort to reduce the time and travel costs associated with ISM verification the team agreed to conduct preliminary training and orientation electronically and by phone. These

  13. Role of computers in CANDU safety systems

    International Nuclear Information System (INIS)

    Hepburn, G.A.; Gilbert, R.S.; Ichiyen, N.M.

    1985-01-01

    Small digital computers are playing an expanding role in the safety systems of CANDU nuclear generating stations, both as active components in the trip logic, and as monitoring and testing systems. The paper describes three recent applications: (i) A programmable controller was retro-fitted to Bruce ''A'' Nuclear Generating Station to handle trip setpoint modification as a function of booster rod insertion. (ii) A centralized monitoring computer to monitor both shutdown systems and the Emergency Coolant Injection system, is currently being retro-fitted to Bruce ''A''. (iii) The implementation of process trips on the CANDU 600 design using microcomputers. While not truly a retrofit, this feature was added very late in the design cycle to increase the margin against spurious trips, and has now seen about 4 unit-years of service at three separate sites. Committed future applications of computers in special safety systems are also described. (author)

  14. Analysis and design on airport safety information management system

    Directory of Open Access Journals (Sweden)

    Yan Lin

    2017-01-01

    Full Text Available Airport safety information management system is the foundation of implementing safety operation, risk control, safety performance monitor, and safety management decision for the airport. The paper puts forward the architecture of airport safety information management system based on B/S model, focuses on safety information processing flow, designs the functional modules and proposes the supporting conditions for system operation. The system construction is helpful to perfecting the long effect mechanism driven by safety information, continually increasing airport safety management level and control proficiency.

  15. Information systems in food safety management

    NARCIS (Netherlands)

    McMeekin, T.A.; Baranyi, J.; Bowman, J.; Dalgaard, P.; Kirk, M.; Ross, T.; Schmid, S.; Zwietering, M.H.

    2006-01-01

    Information systems are concerned with data capture, storage, analysis and retrieval. In the context of food safety management they are vital to assist decision making in a short time frame, potentially allowing decisions to be made and practices to be actioned in real time. Databases with

  16. 77 FR 55371 - System Safety Program

    Science.gov (United States)

    2012-09-07

    ... (AASHTO); American Chemistry Council; American Petroleum Institute; American Public Transportation... group in June 2008 in Baltimore, MD. Additional meetings were held on December 2-4, 2008 in Cambridge... Washington, DC, February 1-2, 2012 in Cambridge, MA, and March 8, 2012 by teleconference. The System Safety...

  17. 77 FR 11120 - Patient Safety Organizations: Voluntary Relinquishment From UAB Health System Patient Safety...

    Science.gov (United States)

    2012-02-24

    ... Organizations: Voluntary Relinquishment From UAB Health System Patient Safety Organization AGENCY: Agency for... notification of voluntary relinquishment from the UAB Health System Patient Safety Organization of its status as a Patient Safety Organization (PSO). The Patient Safety and Quality Improvement Act of 2005...

  18. Maintenance of radiation safety information system

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Sun [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Park, Moon Il; Chung, Chong Kyu; Lim, Bock Soo; Kim, Hyung Uk; Chang, Kwang Il; Nam, Kwan Hyun; Cho, Hye Ryan [AD center incubation LAB, Taejon (Korea, Republic of)

    2001-12-15

    The objectives of radiation safety information system maintenance are to maintain the requirement of users, change of job process and upgrade of the system performance stably and effectively while system maintenance. We conduct the code of conduct recommended by IAEA, management of radioisotope inventory database systematically using analysis for the state of inventory database integrated in this system. This system and database will be support the regulatory guidance, rule making and information to the MOST, KINS, other regulatory related organization and general public optimizationally.

  19. Safety Aspects of Big Cryogenic Systems Design

    Science.gov (United States)

    Chorowski, M.; Fydrych, J.; Poliński, J.

    2010-04-01

    Superconductivity and helium cryogenics are key technologies in the construction of large scientific instruments, like accelerators, fusion reactors or free electron lasers. Such cryogenic systems may contain more than hundred tons of helium, mostly in cold and high-density phases. In spite of the high reliability of the systems, accidental loss of the insulation vacuum, pipe rupture or rapid energy dissipation in the cold helium can not be overlooked. To avoid the danger of over-design pressure rise in the cryostats, they need to be equipped with a helium relief system. Such a system is comprised of safety valves, bursting disks and optionally cold or warm quench lines, collectors and storage tanks. Proper design of the helium safety relief system requires a good understanding of worst case scenarios. Such scenarios will be discussed, taking into account different possible failures of the cryogenic system. In any case it is necessary to estimate heat transfer through degraded vacuum superinsulation and mass flow through the valves and safety disks. Even if the design of the helium relief system does not foresee direct helium venting into the environment, an occasional emergency helium spill may happen. Helium propagation in the atmosphere and the origins of oxygen-deficiency hazards will be discussed.

  20. INTEGRATED SAFETY MANAGEMENT SYSTEM IN AIR TRAFFIC SERVICES

    Directory of Open Access Journals (Sweden)

    Volodymyr Kharchenko

    2014-06-01

    Full Text Available The article deals with the analysis of the researches conducted in the field of safety management systems.Safety management system framework, methods and tools for safety analysis in Air Traffic Control have been reviewed.Principles of development of Integrated safety management system in Air Traffic Services have been proposed.

  1. Security for safety critical space borne systems

    Science.gov (United States)

    Legrand, Sue

    1987-01-01

    The Space Station contains safety critical computer software components in systems that can affect life and vital property. These components require a multilevel secure system that provides dynamic access control of the data and processes involved. A study is under way to define requirements for a security model providing access control through level B3 of the Orange Book. The model will be prototyped at NASA-Johnson Space Center.

  2. Using system dynamics simulation for assessment of hydropower system safety

    Science.gov (United States)

    King, L. M.; Simonovic, S. P.; Hartford, D. N. D.

    2017-08-01

    Hydropower infrastructure systems are complex, high consequence structures which must be operated safely to avoid catastrophic impacts to human life, the environment, and the economy. Dam safety practitioners must have an in-depth understanding of how these systems function under various operating conditions in order to ensure the appropriate measures are taken to reduce system vulnerability. Simulation of system operating conditions allows modelers to investigate system performance from the beginning of an undesirable event to full system recovery. System dynamics simulation facilitates the modeling of dynamic interactions among complex arrangements of system components, providing outputs of system performance that can be used to quantify safety. This paper presents the framework for a modeling approach that can be used to simulate a range of potential operating conditions for a hydropower infrastructure system. Details of the generic hydropower infrastructure system simulation model are provided. A case study is used to evaluate system outcomes in response to a particular earthquake scenario, with two system safety performance measures shown. Results indicate that the simulation model is able to estimate potential measures of system safety which relate to flow conveyance and flow retention. A comparison of operational and upgrade strategies is shown to demonstrate the utility of the model for comparing various operational response strategies, capital upgrade alternatives, and maintenance regimes. Results show that seismic upgrades to the spillway gates provide the largest improvement in system performance for the system and scenario of interest.

  3. Instrumentation and control systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    This Safety Guide was prepared under the IAEA programme for establishing safety standards for nuclear power plants. It supplements Safety Standards Series No. NS-R-1: Safety of Nuclear Power Plants: Design (the Requirements for Design), which establishes the design requirements for ensuring the safety of nuclear power plants. This Safety Guide describes how the requirements should be met for instrumentation and control (I and C) systems important to safety. This publication is a revision and combination of two previous Safety Guides: Safety Series Nos 50-SG-D3 and 50-SG-D8, which are superseded by this new Safety Guide. The revision takes account of developments in I and C systems important to safety since the earlier Safety Guides were published in 1980 and 1984, respectively. The objective of this Safety Guide is to provide guidance on the design of I and C systems important to safety in nuclear power plants, including all I and C components, from the sensors allocated to the mechanical systems to the actuated equipment, operator interfaces and auxiliary equipment. This Safety Guide deals mainly with design requirements for those I and C systems that are important to safety. It expands on paragraphs of Ref in the area of I and C systems important to safety. This publication is intended for use primarily by designers of nuclear power plants and also by owners and/or operators and regulators of nuclear power plants. This Safety Guide provides general guidance on I and C systems important to safety which is broadly applicable to many nuclear power plants. More detailed requirements and limitations for safe operation specific to a particular plant type should be established as part of the design process. The present guidance is focused on the design principles for systems important to safety that warrant particular attention, and should be applied to both the design of new I and C systems and the modernization of existing systems. Guidance is provided on how design

  4. Non-contraceptive benefits of hormonal and intrauterine reversible contraceptive methods.

    Science.gov (United States)

    Bahamondes, Luis; Valeria Bahamondes, M; Shulman, Lee P

    2015-01-01

    Most contraceptive methods present benefits beyond contraception; however, despite a large body of evidence, many healthcare professionals (HCPs), users and potential users are unaware of those benefits. This review evaluates the evidence for non-contraceptive benefits of hormonal and non-hormonal contraceptive methods. We searched the medical publications in PubMed, POPLINE, CENTRAL, EMBASE and LILACS for relevant articles, on non-contraceptive benefits of the use of hormonal and intrauterine reversible contraceptive methods, which were published in English between 1980 and July 2014. Articles were identified using the following search terms: 'contraceptive methods', 'benefits', 'cancer', 'anaemia', 'heavy menstrual bleeding (HMB)', 'endometrial hyperplasia', 'endometriosis' and 'leiomyoma'. We identified, through the literature search, evidence that some combined oral contraceptives have benefits in controlling HMB and anaemia, reducing the rate of endometrial, ovarian and colorectal cancer and ectopic pregnancy as well as alleviating symptoms of premenstrual dysphoric disorder. Furthermore, the use of the levonorgestrel-releasing intrauterine system also controls HMB and anaemia and endometrial hyperplasia and cancer, reduces rates of endometrial polyps in users of tamoxifen and alleviates pain associated with endometriosis and adenomyosis. Depot medroxyprogesterone acetate controls crises of pain associated with sickle cell disease and endometriosis. Users of the etonogestrel-releasing contraceptive implant have the benefits of a reduction of pain associated with endometriosis, and users of the copper intrauterine device have reduced rates of endometrial and cervical cancer. Despite the high contraceptive effectiveness of many hormonal and intrauterine reversible contraceptive methods, many HCPs, users and potential users are concerned mainly about side effects and safety of both hormonal and non-hormonal contraceptive methods, and there is scarce information

  5. Safety of the medical gas pipeline system

    Directory of Open Access Journals (Sweden)

    Sushmita Sarangi

    2018-01-01

    Full Text Available Medical gases are nowadays being used for a number of diverse clinical applications and its piped delivery is a landmark achievement in the field of patient care. Patient safety is of paramount importance in the design, installation, commissioning, and operation of medical gas pipeline systems (MGPS. The system has to be operational round the clock, with practically zero downtime and its failure can be fatal if not restored at the earliest. There is a lack of awareness among the clinicians regarding the medico-legal aspect involved with the MGPS. It is a highly technical field; hence, an in-depth knowledge is a must to ensure safety with the system.

  6. Reactor safety: the Nova computer system

    International Nuclear Information System (INIS)

    Eisgruber, H.; Stadelmann, W.

    1991-01-01

    After instances of maloperation, the causes of defects, the effectiveness of the measures taken to control the situation, and possibilities to avoid future recurrences need to be investigated above all before the plant is restarted. The most important aspect in all these efforts is to check the sequence in time, and the completeness, of the control measures initiated automatically. For this verification, a computer system is used instead of time-consuming manual analytical techniques, which produces the necessary information almost in real time. The results are available within minutes after completion of the measures initiated automatically. As all short-term safety functions are initiated by automatic systems, their consistent and comprehensive verification results in a clearly higher level of safety. The report covers the development of the computer system, and its implementation, in the Gundremmingen nuclear power station. Similar plans are being pursued in Biblis and Muelheim-Kaerlich. (orig.) [de

  7. Unavailability analysis of redundant safety systems

    International Nuclear Information System (INIS)

    Vaurio, J.K.; Sciaudone, D.

    1980-01-01

    Analytical equations have been obtained for the unavailabilities of redundant standby safety systems with components tested periodically. Test and repair contributions, hardware failures, human testing and repair errors as well as failures due to true demands have been taken into account. Equations have been derived for m-out-of-n systems (1 less than or equal to m less than or equal to n less than or equal to 4) with uniformly staggered, consecutive and random testing schemes. The equations have been used in a computer code, ICARUS, and applied to practical safety systems. The results are useful for optimizing the redundancy and testing and they illustrate the importance of human/testing errors and falures associated with true demands

  8. A Methodological Framework for Software Safety in Safety Critical Computer Systems

    OpenAIRE

    P. V. Srinivas Acharyulu; P. Seetharamaiah

    2012-01-01

    Software safety must deal with the principles of safety management, safety engineering and software engineering for developing safety-critical computer systems, with the target of making the system safe, risk-free and fail-safe in addition to provide a clarified differentaition for assessing and evaluating the risk, with the principles of software risk management. Problem statement: Prevailing software quality models, standards were not subsisting in adequately addressing the software safety ...

  9. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  10. Short- and long-term influence of the levonorgestrel-releasing intrauterine system (Mirena®) on vaginal microbiota and Candida.

    Science.gov (United States)

    Donders, Gilbert Gerard Ghislain; Bellen, G; Ruban, Kateryna; Van Bulck, Ben

    2018-03-01

    Recurrent vulvovaginal infections are a frequent complaint in young women in need of contraception. However, the influence of the contraceptive method on the course of the disease is not well known. To investigate the influence of the levonorgestrel-releasing intrauterine-system (LNG-IUS) on the vaginal microflora. Short-term (3 months) and long-term (1 to 5 years) changes of vaginal microbiota were compared with pre-insertion values in 252 women presenting for LNG-IUS insertion. Detailed microscopy on vaginal fluid was used to define lactobacillary grades (LBGs), bacterial vaginosis (BV), aerobic vaginitis (AV) and the presence of Candida. Cultures for enteric aerobic bacteria and Candida were used to back up the microscopy findings. Fisher's test was used to compare vaginal microbiome changes pre- and post-insertion. Compared to the pre-insertion period, we found a temporary worsening in LBGs and increased rates of BV and AV after 3 months of LNG-IUS. After 1 and 5 years, however, these changes were reversed, with a complete restoration to pre-insertion levels. Candida increased significantly after long-term carriage of LNG-IUS compared to the period before insertion [OR 2.0 (CL951.1-3.5), P=0.017]. Short-term use of LNG-IUS temporarily decreases lactobacillary dominance, and increases LBG, AV and BV, but after 1 to 5 years these characteristics return to pre-insertion levels, reducing the risk of complications to baseline levels. Candida colonization, on the other hand, is twice as high after 1 to 5 years of LNG-IUS use, making it less indicated for long-term use in patients with or at risk for recurrent vulvovaginal candidosis.

  11. Impact of the Levonorgestrel-Releasing Intrauterine System on the Progression of Chlamydia trachomatis Infection to Pelvic Inflammatory Disease in a Baboon Model.

    Science.gov (United States)

    Eastman, Alison J; Bergin, Ingrid L; Chai, Daniel; Bassis, Christine M; LeBar, William; Oluoch, George O; Liechty, Emma R; Nyachieo, Atunga; Young, Vincent B; Aronoff, David M; Patton, Dorothy L; Bell, Jason D

    2018-01-30

    Understanding the relationship between the levonorgestrel (LNG)-releasing intrauterine system (IUS) and sexually transmitted infections (STIs) is increasingly important as use of the LNG-IUS grows to include women at higher risk for STIs. This study assessed the impact of the LNG-IUS on development of Chlamydia trachomatis pelvic inflammatory disease, using a baboon model. Baboons with and those without the LNG-IUS were cervically inoculated with C. trachomatis and monitored daily, and cervical and fallopian tube swab specimens were collected weekly for C. trachomatis quantitation by nucleic acid amplification testing and culture. Vaginal swab specimens were collected for cytokine analysis, and serum samples were obtained for detection of C. trachomatis antibodies. The LNG-IUS resulted in an increased C. trachomatis burden in the cervix, with the bacterial burden in the LNG-IUS group diverging from that in the non-LNG-IUS group by 6 weeks after infection. One of 7 baboons in the non-LNG-IUS group and 2 of 6 in the LNG-IUS group developed pelvic inflammatory disease, while 3 animals in each group met criteria suggestive of pelvic inflammatory disease. LNG-IUS increased baseline interleukin 8 levels but failed to further upregulate interleukin 8 during infection. In LNG-IUS recipients, early perturbations in the interleukin 1β axis corresponded to decreased C. trachomatis clearance and increased T-helper type 2 immune responses. LNG-IUS use results in delayed clearance of C. trachomatis and might alter the reproductive tract immune environment. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  12. Effect of a hormone-releasing intrauterine system (Mirena® on aromatase and Cox-2 expression in patients with adenomyosis submitted or not, to endometrial resection

    Directory of Open Access Journals (Sweden)

    Maia R

    2012-04-01

    Full Text Available Hugo Maia Jr1,2, Clarice Haddad1, Julio Casoy1, Rebeca Maia1, Nathanael Pinheiro3, Elsimar M Coutinho11Centro de Pesquisa e Assistência em Reprodução Humana (CEPARH, 2Itaigara Memorial Day Hospital, 3IMAGEPAT, Salvador, Bahia, BrazilObjective: To investigate the effect of a levonorgestrel-releasing intrauterine system (Mirena® on aromatase and cyclooxygenase-2 (Cox-2 expression in the endometrium of patients with adenomyosis who were submitted to endometrial resection at the time of insertion, compared to a group not submitted to endometrial resection and a group of controls with adenomyosis not submitted to any previous hormonal treatment.Patients and methods: Patients with adenomyosis (n = 89 were included in this study. Twenty-two patients had been using Mirena® for 5 years but had not been submitted to endometrial resection prior to insertion of the device. Twenty-four patients were submitted to endometrial resection at the time of Mirena® insertion. The remaining 43 patients with adenomyosis had undergone no previous hormonal treatment and served as a control group. Cox-2 and aromatase expression were determined in the endometrium by immunohistochemistry.Results: Use of Mirena® for 5 years reduced aromatase expression in the endometrium; however, this reduction was significantly greater in the uteri previously submitted to endometrial resection. The reduction in Cox-2 expression was significant only in the uteri submitted to endometrial resection followed by the insertion of Mirena®.Conclusion: Endometrial resection followed by the insertion of Mirena® was associated with greater rates of amenorrhea in patients with adenomyosis, which in turn were associated with a more effective inhibition of aromatase and Cox-2 expression in the endometrium.Keywords: aromatase, Mirena®, adenomyosis, Cox-2, endometrium, levonorgestrel

  13. System analysis of vehicle active safety problem

    Science.gov (United States)

    Buznikov, S. E.

    2018-02-01

    The problem of the road transport safety affects the vital interests of the most of the population and is characterized by a global level of significance. The system analysis of problem of creation of competitive active vehicle safety systems is presented as an interrelated complex of tasks of multi-criterion optimization and dynamic stabilization of the state variables of a controlled object. Solving them requires generation of all possible variants of technical solutions within the software and hardware domains and synthesis of the control, which is close to optimum. For implementing the task of the system analysis the Zwicky “morphological box” method is used. Creation of comprehensive active safety systems involves solution of the problem of preventing typical collisions. For solving it, a structured set of collisions is introduced with its elements being generated also using the Zwicky “morphological box” method. The obstacle speed, the longitudinal acceleration of the controlled object and the unpredictable changes in its movement direction due to certain faults, the road surface condition and the control errors are taken as structure variables that characterize the conditions of collisions. The conditions for preventing typical collisions are presented as inequalities for physical variables that define the state vector of the object and its dynamic limits.

  14. Effect of intracervical anesthesia on pain associated with the insertion of the levonorgestrel-releasing intrauterine system in women without previous vaginal delivery: a RCT.

    Science.gov (United States)

    Castro, T V B; Franceschini, S A; Poli-Neto, O; Ferriani, R A; Silva de Sá, M F; Vieira, C S

    2014-11-01

    Is the pain associated with levonorgestrel-releasing intrauterine system (LNG-IUS) insertion reduced by intracervical anesthesia in women without previous vaginal birth? Intracervical anesthesia was not associated with reduced pain in women without previous vaginal birth. The pain associated with the insertion of intrauterine contraceptives (IUCs) is a limiting factor for the use of these contraceptives by some women. No prophylactic pharmacological intervention has proven efficacy in relieving pain during or after the insertion of IUCs. However, previous studies included women with previous vaginal delivery, and injectable intracervical anesthesia was not evaluated in any of these studies. This was a randomized, open, parallel-group clinical trial that evaluated 100 women without previous vaginal delivery who wished to use the LNG-IUS for the first time. These women were evaluated immediately after LNG-IUS insertion and then 2 h and 6 h later. The 100 women were randomized into two groups: (i) use of a non-steroidal anti-inflammatory drug (NSAID) (ibuprofen, 400 mg) 1 h prior to LNG-IUS insertion; or (ii) 2% lidocaine intracervical injection 5 min prior to LNG-IUS insertion. The women were evaluated immediately after LNG-IUS insertion and then 2 h and 6 h after insertion. Two pain scales were used (the visual analogue scale and the facial pain scale) in addition to assessing the ease of insertion (as rated by the provider) and the level of discomfort during the procedure (as rated by the patient). Multivariate logistic regression was performed to analyze the predictors associated with moderate/severe pain. The pain and discomfort associated with LNG-IUS insertion, and the ease of insertion of the LNG-IUS did not differ between the groups. Nulliparity was more associated with moderate/severe pain [adjusted odds ratio (OR): 3.1 (95% confidence interval (CI): 1.3-7.80]. Injectable intracervical anesthesia use reduced the risk of moderate/severe pain by 40% [adjusted

  15. Safety characteristics of decay heat removal systems

    International Nuclear Information System (INIS)

    Hofmann, F.

    1991-01-01

    Safety features of the decay heat removal systems including power sunply and final heat sink are described. A rather high reliability and an utmost degree of independence from energy supply are goals to be attained in the design of the European Fast Reactor (EFR) decay heat removal scheme. Natural circulation is an ambitious design goal for EFR. All the considerations are performed within the frame of risk minimization

  16. System of its indicator economic safety

    OpenAIRE

    Alexandrova, A.

    2010-01-01

    The thesis is devoted to the scientific and methodological decision of problem of formulation peculiarity economic safety’s guarantying of Ukraine in regional aspect. The scientific ground of optimization economic safety’s management are design. This work describes the bases of research economic safety, define the structure of this category, system of its indicators. Regional features of social and economical development are determined. Various between social and economical development of reg...

  17. Occupational Safety and Health Management System (OSHMS)

    International Nuclear Information System (INIS)

    Shyen, A.K.S.; Mohd Khairul Hakimin; Manisah Saedon

    2011-01-01

    Safe work environment has always been one of the major concerns at workplace. For this, Occupational Safety and Health Act 1994 has been promulgated for all workplaces to ensure the Safety, Health and Welfare of its employees and any person at workplaces. Malaysian Nuclear Agency therefore has started the initiative to review and improve the current Occupational Safety and Health Management System (OSHMS) by going for OHSAS 18001:2007 and MS 1722 standards certification. This would also help in our preparation to bid as the TSO (Technical Support Organization) for the NPP (Nuclear Power Plant) when it is established. With a developed and well maintained OSHMS, it helps to create a safe working condition and thus enhancing the productivity, quality and good morale. Ultimately, this will lead to a greater organization profit. However, successful OSHMS requires full commitment and support from all level of the organization to work hand in hand in implementing the safety and health policy. Therefore it is essential for all to acknowledge the progress of the implementation and be part of it. (author)

  18. Progress report: 1996 Radiation Safety Systems Division

    International Nuclear Information System (INIS)

    Bhagwat, A.M.; Sharma, D.N.; Abani, M.C.; Mehta, S.K.

    1997-01-01

    The activities of Radiation Safety Systems Division include (i) development of specialised monitoring systems and radiation safety information network, (ii) radiation hazards control at the nuclear fuel cycle facilities, the radioisotope programmes at Bhabha Atomic Research Centre (BARC) and for the accelerators programme at BARC and Centre for Advanced Technology (CAT), Indore. The systems on which development and upgradation work was carried out during the year included aerial gamma spectrometer, automated environment monitor using railway network, radioisotope package monitor and air monitors for tritium and alpha active aerosols. Other R and D efforts at the division included assessment of risk for radiation exposures and evaluation of ICRP 60 recommendations in the Indian context, shielding evaluation and dosimetry for the new upcoming accelerator facilities and solid state nuclear track detector techniques for neutron measurements. The expertise of the divisional members was provided for 36 safety committees of BARC and Atomic Energy Regulatory Board (AERB). Twenty three publications were brought out during the year 1996. (author)

  19. Safety analysis of tritium recycling system

    International Nuclear Information System (INIS)

    Yang Yong; Zhang Dong; Xing Shixiong

    2009-04-01

    Safety of a tritium recycling system is analysed according to the structure of the system. The method of accident tree is used to analyse the leakage probability of the system. The result show that the leakage probability of the system failure is 1.1 x 10 -3 and the leakage probability of human fault is 7.2 x 10 -3 , which is are in safe limit. But the leakage probability of human fault is higher than system failure. The MCA will occur because of tritium waste emission cell breakage or misplay, in this case, all tritium in the system will leak, which is about 5.84 TBq. The maximal effective individual dose is 1.24 x 10 -3 mSv, the maximal effective close of the collectivity is 15.33 Person·mSv. (authors)

  20. 46 CFR 62.25-15 - Safety control systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety control systems. 62.25-15 Section 62.25-15... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-15 Safety control systems. (a) Minimum safety trip controls required for specific types of automated vital systems are listed in Table 62...

  1. [Antibody induction after intrauterine interventions].

    Science.gov (United States)

    Hoch, J; Giers, G; Bald, R; Hansmann, M; Hanfland, P

    1993-06-01

    Immunohematologic and clinical data, i.e., antibody profile, location of the placenta, mode of cordocentesis, obtained from 48 pregnant patients with irregular erythrocyte antibodies during the last 2 years have been retrospectively evaluated. All fetuses of the patients received intrauterine transfusions for the treatment of fetal erythroblastosis. In 16 (33%) patients (group I) a secondarily induced antibody was detected after the onset of intrauterine transfusion therapy. 32 (67%) patients (group II) did not further develop new antibody specificities. Group I exhibited a significantly different distribution in the location of the placenta (p pregnant women. In group I a 5-fold higher rate of anterior than posterior placenta location was found. The mode of cordocentesis differed significantly (p antibodies by invasive intrauterine interventions in our patients depended indirectly on the location of the placenta and directly on the mode of the puncture (trans- vs. paraplacental access).

  2. The influence of intrauterine exposure to immunosuppressive treatment on changes in the immune system in juvenile Wistar rats.

    Science.gov (United States)

    Kabat-Koperska, Joanna; Kolasa-Wołosiuk, Agnieszka; Wojciuk, Bartosz; Wojciechowska-Koszko, Iwona; Roszkowska, Paulina; Krasnodębska-Szponder, Barbara; Paczkowska, Edyta; Safranow, Krzysztof; Gołembiewska, Edyta; Machaliński, Bogusław; Ciechanowski, Kazimierz

    2016-01-01

    In our study, we assessed the impact of immunosuppressive drug combinations on changes in the immune system of juvenile Wistar rats exposed to these drugs during pregnancy. We primarily concentrated on changes in two organs of the immune system - the thymus and the spleen. The study was conducted on 40 (32+8) female Wistar rats administered full and half dose of drugs, respectively, subjected to regimens commonly used in therapy of human kidney transplant recipients ([1] cyclosporine A, mycophenolate mofetil, and prednisone; [2] tacrolimus, mycophenolate mofetil, and prednisone; [3] cyclosporine A, everolimus, and prednisone). The animals received drugs by oral gavage 2 weeks before pregnancy and during 3 weeks of pregnancy. There were no statistically significant differences in the weight of the thymus and spleen, but changes were found in the results of blood hematology, cytometry from the spleen, and a histologic examination of the examined immune organs of juvenile Wistar rats. In the cytokine assay, changes in the level of interleukine 17 (IL-17) after increasing amounts of concanavaline A were dose-dependent; the increase of IL-17 was blocked after administration of higher doses of immunosuppressive drugs. However, after a reduction of doses, its increase resumed. Qualitative, quantitative, and morphological changes in the immune system of infant rats born to pharmacologically immunosuppressed females were observed. Thymus structure, spleen composition, and splenocyte IL-17 production were mostly affected in a drug regimen-dependent manner.

  3. The influence of intrauterine exposure to immunosuppressive treatment on changes in the immune system in juvenile Wistar rats

    Directory of Open Access Journals (Sweden)

    Kabat-Koperska J

    2016-07-01

    Full Text Available Joanna Kabat-Koperska,1 Agnieszka Kolasa-Wołosiuk,2 Bartosz Wojciuk,3 Iwona Wojciechowska-Koszko,3 Paulina Roszkowska,3 Barbara Krasnodębska-Szponder,3 Edyta Paczkowska,4 Krzysztof Safranow,5 Edyta Gołembiewska,1 Bogusław Machaliński,4 Kazimierz Ciechanowski1 1Department of Nephrology, Transplantology and Internal Medicine, 2Department of Histology and Embryology, 3Department of Microbiology and Immunological Diagnostics, 4Department of General Pathology, 5Department of Biochemistry and Medical Chemistry, Pomeranian Medical University, Szczecin, Poland Background: In our study, we assessed the impact of immunosuppressive drug combinations on changes in the immune system of juvenile Wistar rats exposed to these drugs during pregnancy. We primarily concentrated on changes in two organs of the immune system – the thymus and the spleen. Methods: The study was conducted on 40 (32+8 female Wistar rats administered full and half dose of drugs, respectively, subjected to regimens commonly used in therapy of human kidney transplant recipients ([1] cyclosporine A, mycophenolate mofetil, and prednisone; [2] tacrolimus, mycophenolate mofetil, and prednisone; [3] cyclosporine A, everolimus, and prednisone. The animals received drugs by oral gavage 2 weeks before pregnancy and during 3 weeks of pregnancy. Results: There were no statistically significant differences in the weight of the thymus and spleen, but changes were found in the results of blood hematology, cytometry from the spleen, and a histologic examination of the examined immune organs of juvenile Wistar rats. In the cytokine assay, changes in the level of interleukine 17 (IL-17 after increasing amounts of concanavaline A were dose-dependent; the increase of IL-17 was blocked after administration of higher doses of immunosuppressive drugs. However, after a reduction of doses, its increase resumed. Conclusion: Qualitative, quantitative, and morphological changes in the immune system of infant

  4. Safety Analysis of Stochastic Dynamical Systems

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Wisniewski, Rafael

    2015-01-01

    This paper presents a method for verifying the safety of a stochastic system. In particular, we show how to compute the largest set of initial conditions such that a given stochastic system is safe with probability p. To compute the set of initial conditions we rely on the moment method that via...... Haviland's theorem allows an infinite dimensional optimization problem on measures to be formulated as a polynomial optimization problem. Subsequently, the moment sequence is truncated (relaxed) to obtain a finite dimensional polynomial optimization problem. Finally, we provide an illustrative example...

  5. ESSAA: Embedded system safety analysis assistant

    Science.gov (United States)

    Wallace, Peter; Holzer, Joseph; Guarro, Sergio; Hyatt, Larry

    1987-01-01

    The Embedded System Safety Analysis Assistant (ESSAA) is a knowledge-based tool that can assist in identifying disaster scenarios. Imbedded software issues hazardous control commands to the surrounding hardware. ESSAA is intended to work from outputs to inputs, as a complement to simulation and verification methods. Rather than treating the software in isolation, it examines the context in which the software is to be deployed. Given a specified disasterous outcome, ESSAA works from a qualitative, abstract model of the complete system to infer sets of environmental conditions and/or failures that could cause a disasterous outcome. The scenarios can then be examined in depth for plausibility using existing techniques.

  6. Product Engineering Class in the Software Safety Risk Taxonomy for Building Safety-Critical Systems

    Science.gov (United States)

    Hill, Janice; Victor, Daniel

    2008-01-01

    When software safety requirements are imposed on legacy safety-critical systems, retrospective safety cases need to be formulated as part of recertifying the systems for further use and risks must be documented and managed to give confidence for reusing the systems. The SEJ Software Development Risk Taxonomy [4] focuses on general software development issues. It does not, however, cover all the safety risks. The Software Safety Risk Taxonomy [8] was developed which provides a construct for eliciting and categorizing software safety risks in a straightforward manner. In this paper, we present extended work on the taxonomy for safety that incorporates the additional issues inherent in the development and maintenance of safety-critical systems with software. An instrument called a Software Safety Risk Taxonomy Based Questionnaire (TBQ) is generated containing questions addressing each safety attribute in the Software Safety Risk Taxonomy. Software safety risks are surfaced using the new TBQ and then analyzed. In this paper we give the definitions for the specialized Product Engineering Class within the Software Safety Risk Taxonomy. At the end of the paper, we present the tool known as the 'Legacy Systems Risk Database Tool' that is used to collect and analyze the data required to show traceability to a particular safety standard

  7. Total Quality Management and the System Safety Secretary

    Science.gov (United States)

    Elliott, Suzan E.

    1993-01-01

    The system safety secretary is a valuable member of the system safety team. As downsizing occurs to meet economic constraints, the Total Quality Management (TQM) approach is frequently adopted as a formula for success and, in some cases, for survival.

  8. Integrated environment, safety, and health management system description

    International Nuclear Information System (INIS)

    Zoghbi, J. G.

    2000-01-01

    The Integrated Environment, Safety, and Health Management System Description that is presented in this document describes the approach and management systems used to address integrated safety management within the Richland Environmental Restoration Project

  9. Development of Safety Assessment Information System (SAIS)

    International Nuclear Information System (INIS)

    Park, Byung Shik; Lee, Kyung Jin; Lee, Byung Chul; Song, Tae Young; Lee, Chang Ho

    2007-01-01

    Many reports and documents about nuclear power plant safety analysis like a Periodic Safe Review (PSR), Periodic Safety Analysis (PSA) and Severe Accident Management Guideline (SAMG) come to be drawn up from KHNP. Since these are not arranged easy to look up, the systematic arrangement of data was necessary. The solution against hereupon is to store database, and it was developed with the name, SAIS, by FNC Tech. Co. together with NETEC KHNP. In this web program it is easy to manage (registration, search and statistics) data. And the authorized user can approach this system. This was developed, and was verified under the development environment of; - Web Server : Apache 2.2.5 - Program Language : PHP 5.2 - DBMS : Oracle 10g

  10. Glucocorticoids as regulatory signals during intrauterine development.

    Science.gov (United States)

    Fowden, Abigail L; Forhead, Alison J

    2015-12-01

    What is the topic of this review? This review discusses the role of the glucocorticoids as regulatory signals during intrauterine development. It examines the functional significance of these hormones as maturational, environmental and programming signals in determining offspring phenotype. What advances does it highlight? It focuses on the extensive nature of the regulatory actions of these hormones. It highlights the emerging data that these actions are mediated, in part, by the placenta, other endocrine systems and epigenetic modifications of the genome. Glucocorticoids are important regulatory signals during intrauterine development. They act as maturational, environmental and programming signals that modify the developing phenotype to optimize offspring viability and fitness. They affect development of a wide range of fetal tissues by inducing changes in cellular expression of structural, transport and signalling proteins, which have widespread functional consequences at the whole organ and systems levels. Glucocorticoids, therefore, activate many of the physiological systems that have little function in utero but are vital at birth to replace the respiratory, nutritive and excretory functions previously carried out by the placenta. However, by switching tissues from accretion to differentiation, early glucocorticoid overexposure in response to adverse conditions can programme fetal development with longer term physiological consequences for the adult offspring, which can extend to the next generation. The developmental effects of the glucocorticoids can be direct on fetal tissues with glucocorticoid receptors or mediated by changes in placental function or other endocrine systems. At the molecular level, glucocorticoids can act directly on gene transcription via their receptors or indirectly by epigenetic modifications of the genome. In this review, we examine the role and functional significance of glucocorticoids as regulatory signals during intrauterine

  11. Safety Implications Concerning Usage of Tools in Complex System

    OpenAIRE

    Augusto, Rafael; Silva, Nuno

    2016-01-01

    International audience; Integration of tools and configuration data is nowadays present in all railway systems and plays a central role in functionality, flexibility and the safety of railway systems. This paper aims to present the challenges and the importance of tools, the configuration data integrity and the toolchain definition in the design of railway systems safety. We focus on the relevant implications on the safety analysis and safety assurance of such systems. Two examples of the usa...

  12. An Estimation of the Risk of Pseudotumor Cerebri among Users of the Levonorgestrel Intrauterine Device

    DEFF Research Database (Denmark)

    Valenzuela, Reuben M; Rai, Ruju; Kirk, Brian H

    2017-01-01

    Because of a previous association of pseudotumor cerebri (PTC) with levonorgestrel, we wished to evaluate the use of levonorgestrel-eluting intrauterine devices ("levonorgestrel intrauterine systems", LNG-IUS) in our University of Utah and Rigshospitalet PTC patients. In our retrospective series...

  13. Safety Analysis for Power Reactor Protection System

    International Nuclear Information System (INIS)

    Eisawy, E.A.; Sallam, H.

    2012-01-01

    The main function of a Reactor Protection System (RPS) is to safely shutdown the reactor and prevents the release of radioactive materials. The purpose of this paper is to present a technique and its application for used in the analysis of safety system of the Nuclear Power Plant (NPP). A more advanced technique has been presented to accurately study such problems as the plant availability assessments and Technical Specifications evaluations that are becoming increasingly important. The paper provides the Markov model for the Reactor Protection System of the NPP and presents results of model evaluations for two testing policies in technical specifications. The quantification of the Markov model provides the probability values that the system will occupy each of the possible states as a function of time.

  14. Development of Network Protocol for the Integrated Safety System

    International Nuclear Information System (INIS)

    Park, S. W.; Baek, J. I.; Lee, S. H.; Park, C. S.; Park, K. H.; Shin, J. M.

    2007-06-01

    Communication devices in the safety system of nuclear power plants are distinguished from those developed for commercial purposes in terms of a strict requirement of safety. The concept of safety covers the determinability, the reliability, and the separation/isolation to prevent the undesirable interactions among devices. The safety also requires that these properties be never proof less. Most of the current commercialized communication products rarely have the safety properties. Moreover, they can be neither verified nor validated to satisfy the safety property of implementation process. This research proposes the novel architecture and protocol of a data communication network for the safety system in nuclear power plants

  15. Development of Network Protocol for the Integrated Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. W.; Baek, J. I.; Lee, S. H.; Park, C. S.; Park, K. H.; Shin, J. M. [Hannam Univ., Daejeon (Korea, Republic of)

    2007-06-15

    Communication devices in the safety system of nuclear power plants are distinguished from those developed for commercial purposes in terms of a strict requirement of safety. The concept of safety covers the determinability, the reliability, and the separation/isolation to prevent the undesirable interactions among devices. The safety also requires that these properties be never proof less. Most of the current commercialized communication products rarely have the safety properties. Moreover, they can be neither verified nor validated to satisfy the safety property of implementation process. This research proposes the novel architecture and protocol of a data communication network for the safety system in nuclear power plants.

  16. Safety systems and safety analysis of the Qinshan phase III CANDU nuclear power plant

    International Nuclear Information System (INIS)

    Cai Jianping; Shen Sen; Barkman, N.

    1999-01-01

    The author introduces the Canadian nuclear reactor safety philosophy and the Qinshan Phase III CANDU NPP safety systems and safety analysis, which are designed and performed according to this philosophy. The concept of 'defence-in-depth' is a key element of the Canadian nuclear reactor safety philosophy. The design concepts of redundancy, diversity, separation, equipment qualification, quality assurance, and use of appropriate design codes and standards are adopted in the design. Four special safety systems as well as a set of reliable safety support systems are incorporated in the design of Qinshan phase III CANDU for accident mitigation. The assessment results for safety systems performance show that the fundamental safety criteria for public dose, and integrity of fuel, channels and the reactor building, are satisfied

  17. NASA System Safety Handbook. Volume 1; System Safety Framework and Concepts for Implementation

    Science.gov (United States)

    Dezfuli, Homayoon; Benjamin, Allan; Everett, Christopher; Smith, Curtis; Stamatelatos, Michael; Youngblood, Robert

    2011-01-01

    System safety assessment is defined in NPR 8715.3C, NASA General Safety Program Requirements as a disciplined, systematic approach to the analysis of risks resulting from hazards that can affect humans, the environment, and mission assets. Achievement of the highest practicable degree of system safety is one of NASA's highest priorities. Traditionally, system safety assessment at NASA and elsewhere has focused on the application of a set of safety analysis tools to identify safety risks and formulate effective controls.1 Familiar tools used for this purpose include various forms of hazard analyses, failure modes and effects analyses, and probabilistic safety assessment (commonly also referred to as probabilistic risk assessment (PRA)). In the past, it has been assumed that to show that a system is safe, it is sufficient to provide assurance that the process for identifying the hazards has been as comprehensive as possible and that each identified hazard has one or more associated controls. The NASA Aerospace Safety Advisory Panel (ASAP) has made several statements in its annual reports supporting a more holistic approach. In 2006, it recommended that "... a comprehensive risk assessment, communication and acceptance process be implemented to ensure that overall launch risk is considered in an integrated and consistent manner." In 2009, it advocated for "... a process for using a risk-informed design approach to produce a design that is optimally and sufficiently safe." As a rationale for the latter advocacy, it stated that "... the ASAP applauds switching to a performance-based approach because it emphasizes early risk identification to guide designs, thus enabling creative design approaches that might be more efficient, safer, or both." For purposes of this preface, it is worth mentioning three areas where the handbook emphasizes a more holistic type of thinking. First, the handbook takes the position that it is important to not just focus on risk on an individual

  18. Safety Evaluation of Fail-Safe Fieldbus in Safety Related Control System

    Science.gov (United States)

    Franeková, Mária; Rástočný, Karol

    2010-11-01

    The paper deals with the problem of modelling safety features of the safety Fieldbus transmission system used within safety related control systems. The basic principles of the modelling failures effect upon the safety of closed transmission system and standards used in the process of safety evaluation are summarized in the paper. The practical part is oriented to a description of a realized Markov model for determination of the random failures effect on the safety of a closed transmission system. The model reflects the safety analysis of failures effect caused by electromagnetic interference in the communication channel and random HW failures of the transmission system. In the paper the results of simulation of parameters of the transmission system are discussed, such as the probability of an undetected corrupted message.

  19. Levonorgestrel-releasing intrauterine system vs oral progestins for non-atypical endometrial hyperplasia: a systematic review and metaanalysis of randomized trials.

    Science.gov (United States)

    Abu Hashim, Hatem; Ghayaty, Essam; El Rakhawy, Mohamed

    2015-10-01

    We sought to evaluate the therapeutic efficacy of levonorgestrel-releasing intrauterine system (LNG-IUS) with oral progestins for treatment of non-atypical endometrial hyperplasia (EH). Searches were conducted on PubMed, SCOPUS, and CENTRAL databases to August 2014, and reference lists of relevant articles were screened. The search was limited to articles conducted on human beings and females. The PRISMA Statement was followed. Seven randomized controlled trials (n = 766 women) were included. Main outcome measures were the therapeutic effect rate (histological response) after 3, 6, 12, and 24 months of treatment; rate of irregular vaginal bleeding; and the hysterectomy rate per woman randomized. The Cochrane Collaboration risk of bias tool was used for quality assessment. Metaanalysis was performed with fixed effects model. LNG-IUS achieved a highly significant therapeutic response rate compared with oral progestins after 3 months of treatment (odds ratio [OR], 2.30; 95% confidence interval [CI], 1.39-3.82; P = .001, 5 trials, I(2) = 0%, n = 376), after 6 months of treatment (OR, 3.16; 95% CI, 1.84-5.45; P trials, I(2) = 0%, n = 397), after 12 months of treatment (OR, 5.73; 95% CI, 2.67-12.33; P trials, I(2) = 0%, n = 224), and after 24 months of treatment (OR, 7.46; 95% CI, 2.55-21.78; P = .0002, 1 trial, n = 104). Subgroup analysis showed evidence of highly significant therapeutic response following LNG-IUS compared with oral progestins for non-atypical simple as well as complex EH (OR, 2.51; 95% CI, 1.14-5.53; P = .02, 6 trials, I(2) = 0%, n = 290; and OR, 3.31; 95% CI, 1.62-6.74; P = .001, 4 trials, I(2) = 0%, n = 216, respectively). Compared with oral progestins, LNG-IUS achieved significantly fewer hysterectomies (OR, 0.26; 95% CI, 0.15-0.45; P trials, n = 362, I² = 42%). No difference was observed in the rate of irregular vaginal bleeding between both groups (OR, 1.12; 95% CI, 0.54-2.32; P = .76, 2 trials, n = 207, I² = 77%). Funnel plot analysis was not

  20. Heterotopic pregnancy following intrauterine insemination ...

    African Journals Online (AJOL)

    2011-04-27

    Apr 27, 2011 ... Clomiphene citrate, gonadotropin stimulation (hCG), and intrauterine insemination using donor sperm. The resulting pregnancy was later diagnosed as heterotopic pregnancy ... Presence of corpus luteum cyst of pregnancy in early ultrasound should be an index of suspicious of a possible heterotopic ...

  1. Information systems in food safety management.

    Science.gov (United States)

    McMeekin, T A; Baranyi, J; Bowman, J; Dalgaard, P; Kirk, M; Ross, T; Schmid, S; Zwietering, M H

    2006-12-01

    Information systems are concerned with data capture, storage, analysis and retrieval. In the context of food safety management they are vital to assist decision making in a short time frame, potentially allowing decisions to be made and practices to be actioned in real time. Databases with information on microorganisms pertinent to the identification of foodborne pathogens, response of microbial populations to the environment and characteristics of foods and processing conditions are the cornerstone of food safety management systems. Such databases find application in: Identifying pathogens in food at the genus or species level using applied systematics in automated ways. Identifying pathogens below the species level by molecular subtyping, an approach successfully applied in epidemiological investigations of foodborne disease and the basis for national surveillance programs. Predictive modelling software, such as the Pathogen Modeling Program and Growth Predictor (that took over the main functions of Food Micromodel) the raw data of which were combined as the genesis of an international web based searchable database (ComBase). Expert systems combining databases on microbial characteristics, food composition and processing information with the resulting "pattern match" indicating problems that may arise from changes in product formulation or processing conditions. Computer software packages to aid the practical application of HACCP and risk assessment and decision trees to bring logical sequences to establishing and modifying food safety management practices. In addition there are many other uses of information systems that benefit food safety more globally, including: Rapid dissemination of information on foodborne disease outbreaks via websites or list servers carrying commentary from many sources, including the press and interest groups, on the reasons for and consequences of foodborne disease incidents. Active surveillance networks allowing rapid dissemination

  2. ISO 22000 FOOD SAFETY MANAGEMENT SYSTEM

    OpenAIRE

    Başaran, Burhan

    2015-01-01

    The increase in the level of welfare of the countriesand the awareness of the consumers have forced the firms in the food sector toseek for new pursuits. In this re­gard, ISO 22000 is the most commonlypreferred food safety system. This study aims to contribute the share­holdersand the researchers studying this topic by in­terpreting the lateststudies in this field and determine the critical relationships inorder to picture an effective and productive implementation ofISO22000 which is one of ...

  3. The WIPP transportation system: Dedicated to safety

    International Nuclear Information System (INIS)

    Ward, T.; McFadden, M.

    1993-01-01

    When developing a transportation system to transport transuranic (TRU) waste from ten widely-dispersed generator sites, the Department of Energy (DOE) recognized and addressed many challenges. Shipments of waste to the Waste Isolation Pilot Plant (WIPP) were to cover a twenty-five year period and utilize routes covering over twelve thousand miles in twenty-three states. Enhancing public safety by maximizing the payload, thus reducing the number of shipments, was the primary objective. To preclude the requirement for overweight permits, the DOE started with a total shipment weight limit of 80,000 pounds and developed an integrated transportation system consisting of a Type ''B'' package to transport the material, a lightweight tractor and trailer, stringent driver requirements, and a shipment tracking system referred to as ''TRANSCOM''

  4. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  5. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  6. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2000-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  7. Remote mobile communication in safety support system

    International Nuclear Information System (INIS)

    Inagaki, Kanji; Kobayashi, Hiroyuki; Hatanaka, Takahiro; Sakuma, Akira; Fukumoto, Akira; Ikeda, Jun

    1999-01-01

    Safety Support System (SSS) is a computerized operator support system for nuclear power plants, which is now under development. The concept of SSS covers 1) earlier detection of failure symptom and prediction of its influence to the plant operation, 2) improved transparency and robustness of plant control systems, 3) advanced human-machine interface and communication. The authors have been working on the third concept and proposed a remote mobile communication system called Plant Communication System (PCS). PCS aims to realize convenient communication between main control room and other areas such as plant local areas and site offices, using Personal Handyphone System (PHS) and wireless LAN (Local Area Network). PCS can transmit not only data but also graphic displays and dynamic video displays between the main control room and plant local areas. MPEG4 (Moving Picture Experts Group 4) technology is utilized in video data compression and decompression. The authors have developed the special multiplexing unit that connects PHS Cell Stations (CSs) and exiting coaxial cables. Voice recognition and announcement capability is also realized in the system, which enables verbal retrieval of information in the computer systems in the main control room from local areas. (author)

  8. The intrauterine device: dispelling the myths.

    Science.gov (United States)

    Kimble-Haas, S L

    1998-11-01

    The worldwide popularity and usage of intrauterine devices (IUDs) plummeted in the 1970s, when grim reports of septic abortions and pelvic inflammatory disease were published. Although the Dalkon Shield ultimately was determined to be the culprit for these problems, the reputation of all IUDs was damaged, and their popularity spiraled downward. The stigma continues, despite the proven safety and efficacy of newer IUDs, particularly the ParaGard T 380A and the Progestasert, which are now the only two IUDs approved for use in the United States. This article will review how the IUD works and will focus on dispelling the misconceptions surrounding its use. Rigid patient-selection guidelines and strict aseptic insertion techniques can provide safe, long-term, cost-effective, and highly efficacious contraception for monogamous women. Practitioners who follow these guidelines should not fear prescribing IUDs as a contraceptive device in the appropriate female population.

  9. Modelling safety of multistate systems with ageing components

    Energy Technology Data Exchange (ETDEWEB)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna [Gdynia Maritime University, Department of Mathematics ul. Morska 81-87, Gdynia 81-225 Poland (Poland)

    2016-06-08

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics of the consecutive “m out of n: F” is presented as well.

  10. An Approach to Modeling Software Safety in Safety-Critical Systems

    OpenAIRE

    Ben S. Medikonda; Seetha R. Panchumarthy

    2009-01-01

    Software for safety-critical systems has to deal with the hazards identified by safety analysis in order to make the system safe, risk-free and fail-safe. Software safety is a composite of many factors. Problem statement: Existing software quality models like McCalls and Boehms and ISO 9126 were inadequate in addressing the software safety issues of real time safety-critical embedded systems. At present there does not exist any standard framework that comprehensively addresses the Factors, Cr...

  11. Design for safety: theoretical framework of the safety aspect of BIM system to determine the safety index

    Directory of Open Access Journals (Sweden)

    Ai Lin Evelyn Teo

    2016-12-01

    Full Text Available Despite the safety improvement drive that has been implemented in the construction industry in Singapore for many years, the industry continues to report the highest number of workplace fatalities, compared to other industries. The purpose of this paper is to discuss the theoretical framework of the safety aspect of a proposed BIM System to determine a Safety Index. An online questionnaire survey was conducted to ascertain the current workplace safety and health situation in the construction industry and explore how BIM can be used to improve safety performance in the industry. A safety hazard library was developed based on the main contributors to fatal accidents in the construction industry, determined from the formal records and existing literature, and a series of discussions with representatives from the Workplace Safety and Health Institute (WSH Institute in Singapore. The results from the survey suggested that the majority of the firms have implemented the necessary policies, programmes and procedures on Workplace Safety and Health (WSH practices. However, BIM is still not widely applied or explored beyond the mandatory requirement that building plans should be submitted to the authorities for approval in BIM format. This paper presents a discussion of the safety aspect of the Intelligent Productivity and Safety System (IPASS developed in the study. IPASS is an intelligent system incorporating the buildable design concept, theory on the detection, prevention and control of hazards, and the Construction Safety Audit Scoring System (ConSASS. The system is based on the premise that safety should be considered at the design stage, and BIM can be an effective tool to facilitate the efforts to enhance safety performance. IPASS allows users to analyse and monitor key aspects of the safety performance of the project before the project starts and as the project progresses.

  12. Model-based safety architecture framework for complex systems

    NARCIS (Netherlands)

    Schuitemaker, Katja; Rajabali Nejad, Mohammadreza; Braakhuis, J.G.; Podofillini, Luca; Sudret, Bruno; Stojadinovic, Bozidar; Zio, Enrico; Kröger, Wolfgang

    2015-01-01

    The shift to transparency and rising need of the general public for safety, together with the increasing complexity and interdisciplinarity of modern safety-critical Systems of Systems (SoS) have resulted in a Model-Based Safety Architecture Framework (MBSAF) for capturing and sharing architectural

  13. Developing and maintaining national food safety control systems ...

    African Journals Online (AJOL)

    The establishment of effective food safety systems is pivotal to ensuring the safety of the national food supply as well as food products for regional and international trade. The development, structure and implementation of modern food safety systems have been driven over the years by a number of developments.

  14. Examining the Relationship between Safety Management System Implementation and Safety Culture in Collegiate Flight Schools

    Science.gov (United States)

    Robertson, Mike Fuller

    2017-01-01

    Safety Management Systems (SMS) are becoming the industry standard for safety management throughout the aviation industry. As the Federal Aviation Administration (FAA) continues to mandate SMS for different segments, the assessment of an organization's safety culture becomes more important. An SMS can facilitate the development of a strong…

  15. Safety Management for the Cryogenic System of Superconducting RF System

    CERN Document Server

    Kao, Sheau-Ping; Hsiao, Feng-Zone; Wang, Jau-Ping

    2005-01-01

    The installation of the helium cryogenic system for the superconducting RF cavity and magnet were finished in the National Synchrotron Radiation Research Center (NSRRC) at the end of October 2002. The first phase of this program will be commissioned at the end of 2004. This was the first large scale cryogenic system in Taiwan. The major hazards to personnel are cryogenic burn and oxygen deficient. To avoid the injury of the operators and meet the requirements of local laws and regulations, some safety measures must be adopted. This paper will illustrate the methods of risk evaluation and the safety control programs taken at NSRRC to avoid and reduce the hazards from the cryogenic system of the superconducting RF cavity and magnet system.

  16. Assessment of Safety Standards for Automotive Electronic Control Systems

    Science.gov (United States)

    2016-06-01

    This report summarizes the results of a study that assessed and compared six industry and government safety standards relevant to the safety and reliability of automotive electronic control systems. These standards include ISO 26262 (Road Vehicles - ...

  17. Regulatory Oversight of Safety Culture in Finland: A Systemic Approach to Safety

    International Nuclear Information System (INIS)

    Oedewald, P.; Väisäsvaara, J.

    2016-01-01

    In Finland the Radiation and Nuclear Safety Authority STUK specifies detailed regulatory requirements for good safety culture. Both the requirements and the practical safety culture oversight activities reflect a systemic approach to safety: the interconnections between the technical, human and organizational factors receive special attention. The conference paper aims to show how the oversight of safety culture can be integrated into everyday oversight activities. The paper also emphasises that the scope of the safety culture oversight is not specific safety culture activities of the licencees, but rather the overall functioning of the licence holder or the new build project organization from safety point of view. The regulatory approach towards human and organizational factors and safety culture has evolved throughout the years of nuclear energy production in Finland. Especially the recent new build projects have highlighted the need to systematically pay attention to the non-technical aspects of safety as it has become obvious how the HOF issues can affect the design processes and quality of construction work. Current regulatory guides include a set of safety culture related requirements. The requirements are binding to the licence holders and they set both generic and specific demands on the licencee to understand, monitor and to develop safety culture of their own organization but also that of their supplier network. The requirements set for the licence holders has facilitated the need to develop the regulator’s safety culture oversight practices towards a proactive and systemic approach.

  18. Identifying behaviour patterns of construction safety using system archetypes.

    Science.gov (United States)

    Guo, Brian H W; Yiu, Tak Wing; González, Vicente A

    2015-07-01

    Construction safety management involves complex issues (e.g., different trades, multi-organizational project structure, constantly changing work environment, and transient workforce). Systems thinking is widely considered as an effective approach to understanding and managing the complexity. This paper aims to better understand dynamic complexity of construction safety management by exploring archetypes of construction safety. To achieve this, this paper adopted the ground theory method (GTM) and 22 interviews were conducted with participants in various positions (government safety inspector, client, health and safety manager, safety consultant, safety auditor, and safety researcher). Eight archetypes were emerged from the collected data: (1) safety regulations, (2) incentive programs, (3) procurement and safety, (4) safety management in small businesses (5) production and safety, (6) workers' conflicting goals, (7) blame on workers, and (8) reactive and proactive learning. These archetypes capture the interactions between a wide range of factors within various hierarchical levels and subsystems. As a free-standing tool, they advance the understanding of dynamic complexity of construction safety management and provide systemic insights into dealing with the complexity. They also can facilitate system dynamics modelling of construction safety process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Short course on system safety analysis

    International Nuclear Information System (INIS)

    Sudmann, R.H.

    1992-01-01

    This course provides and introduction to methods generally used in safety analysis and accident investigation. It is a non-mathematical approach, directed toward a casual user. The participant will learn techniques allowing them to dissect a system or incident in order identify real or potential safety problems. These techniques will be applied to analyze events which have occurred within DOE facilities. As a manager or staff person with general oversight responsibilities, the participant should gain an awareness of the big picture and not just ''dig for facts.'' This can be accomplished by being alert and responsive to the atmosphere and condition of the plant; mood and impression of the worker and the behavioral climate. The techniques taught in the course can be used to identify critical areas or indicators. These indicators will signal problems before the ''facts'' will. Analysis techniques taught are used to gauge the breadth of the ''forest'' and not necessarily to identify the trees. For this course includes a technical background with experience in a chemical processing operations and a knowledge of basic chemistry and engineering is desirable. The course should help in a present or future assignment in an oversight role

  20. Lessons learned on digital systems safety

    International Nuclear Information System (INIS)

    Sivertsen, Terje

    2005-06-01

    A decade ago, in 1994, lessons learned from Halden research activities on digital systems safety were summarized in the reports HWR-374 and HWR-375, under the title 'A Lessons Learned Report on Software Dependability'. The reports reviewed all activities made at the Halden Project in this field since 1977. As such, the reports provide a wealth of information on Halden research. At the same time, the lessons learned from the different activities are made more accessible to the reader by being summarized in terms of results, conclusions and recommendations. The present report provides a new lessons learned report, covering the Halden Project research activities in this area from 1994 to medio 2005. As before, the emphasis is on the results, conclusions and recommendations made from these activities, in particular how they can be utilized by different types of organisations, such as licensing authorities, safety assessors, power companies, and software developers. The contents of the report have been edited on the basis of input from a large number of Halden work reports, involving many different authors. Brief summaries of these reports are included in the last part of the report. (Author)

  1. 78 FR 29392 - Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied...

    Science.gov (United States)

    2013-05-20

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0098] Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied on for Safety AGENCY: Nuclear Regulatory Commission. ACTION... (NRC) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2013-XX, ``Embedded Digital...

  2. [Intrauterine herpes simplex virus infection].

    Science.gov (United States)

    Hoppen, T; Eis-Hübinger, A M; Schild, R L; Enders, G; Hansmann, M; Rister, M; Bartmann, P

    2001-01-01

    Early fetal herpes simplex virus (HSV) infection is rarely documented. Only the minority of affected fetuses survive this condition. At 19 weeks of gestation the first episode of a genital HSV-infection of a pregnant woman was treated with local interferon beta. At 34 weeks of gestation hydrocephalus with secondary microcephaly and microphthalmia of both eyes was detected by ultrasonography. In the amniotic fluid HSV type 2 (HSV-2) was isolated and HSV-2-DNA was detected by PCR. The serum of the mother proved positive for HSV-2 (glycoprotein G2)-specific IgG-antibodies. No other infectious causes were apparent on further testing. At 35 + 4 weeks gestation a small-for-gestational-age neonate (2130 g) with microcephaly (29 cm head circumference) was born by spontaneous vaginal delivery. Scarce ulcerative skin lesions and vesicles, hepatosplenomegaly and microphthalmia were diagnosed. Furthermore, encephalomalacia with parenchymal destruction, cataract of both eyes and aplasia of the maculae and papillae were found. HSV-2-PCR was tested positive in chorionic cells and an umbilical segment of the placenta as well as in swabs from both eyes, throat, and a herpetic skin lesion collected during the first 5 days of life. HSV-IgM-antibodies were found in the umbilical cord blood. Local and intravenous treatment with aciclovir was started. The infant exhibited signs of a severely malfunctioning central nervous system. At the age of 4 months the boy suffered from generalised cerebral seizures. He died at the age of 9 months as a consequence of respiratory insufficiency with consecutive circulation failure. The case of an intrauterine HSV-2-infection is presented. The time of onset of fetal infection was most probably at the time of the maternal disease (19 weeks of gestation). Inspite of the very early infection the fetus did not die in utero. Especially, if a primary genital HSV-2-infection of a pregnant woman is suspected, which can be proven by serological means only

  3. Ovarian transmigration of intrauterine device.

    Science.gov (United States)

    Rovati, Marco; Raveglia, Federico; Baisi, Alessandro; De Simone, Matilde; Cioffi, Ugo

    2016-12-01

    Extrauterine translocation of intrauterine device (IUD) to peritoneal cavity is an uncommon event, moreover the ovarian embedding of a transmigrated IUD is very rare, and only two previous cases have been reported in the literature. We present a single case treated with laparoscopy. The aims of this study were to focus attention on the utility of preoperative computed tomography in planning the best surgical approach and to describe the two-port technique. © 2016 Japan Society of Obstetrics and Gynecology.

  4. Development and applications of a safety assessment system for promoting safety culture in nuclear power plants

    International Nuclear Information System (INIS)

    Takano, Ken-ichi; Hasegawa, Naoko; Hirose, Ayako; Hayase, Ken-ichi

    2004-01-01

    For past five years, CRIEPI has been continuing efforts to develop and make applications of a 'safety assessment system' which enable to measure the safety level of organization. This report describe about frame of the system, assessment results and its reliability, and relation between labor accident rate in the site and total safety index (TSI), which can be obtained by the principal factors analysis. The safety assessment in this report is based on questionnaire survey of employee. The format and concrete questionnaires were developed using existing literatures including organizational assessment tools. The tailored questionnaire format involved 124 questionnaire items. The assessment results could be considered as a well indicator of the safety level of organization, safety management, and safety awareness of employee. (author)

  5. Development and implementation of setpoint tolerances for special safety systems

    International Nuclear Information System (INIS)

    Oliva, A.F.; Balog, G.; Parkinson, D.G.; Archinoff, G.H.

    1991-01-01

    The establishment of tolerances and impairment limits for special safety system setpoints is part of the process whereby the plant operator demonstrates to the regulatory authority that the plant operates safely and within the defined plant licensing envelope. The licensing envelope represents the set of limits and plant operating state and for which acceptably safe plant operation has been demonstrated by the safety analysis. By definition, operation beyond this envelope contributes to overall safety system unavailability. Definition of the licensing envelope is provided in a wide range of documents including the plant operating licence, the safety report, and the plant operating policies and principles documents. As part of the safety analysis, limits are derived for each special safety system initiating parameter such that the relevant safety design objectives are achieved for all design basis events. If initiation on a given parameter occurs at a level beyond its limit, there is a potential reduction in safety system effectiveness relative to the performance credited in the plant safety analysis. These safety system parameter limits, when corrected for random and systematic instrument errors and other errors inherent in the process of periodic testing or calibration, are then used to derive parameter impairment levels and setpoint tolerances. This paper describes the methodology that has evolved at Ontario Hydro for developing and implementing tolerances for special safety system parameters (i.e., the shutdown systems, emergency coolant injection system and containment system). Tolerances for special safety system initiation setpoints are addressed specifically, although many of the considerations discussed here will apply to performance limits for other safety system components. The first part of the paper deals with the approach that has been adopted for defining and establishing setpoint limits and tolerances. The remainder of the paper addresses operational

  6. Analysis of road safety management systems in Europe.

    NARCIS (Netherlands)

    Muhlrad, N. Vallet, G. Butler, I. Gitelman, V. Doveh, E. Dupont, E. Thomas, P. Talbot, R. Papadimitriou, E. Yannis, G. Persia, L. Giustiniani, G. Machata, K. & Bax, C.A.

    2014-01-01

    The objective of this paper is the analysis of road safety management in European countries and the identification of “good practice”. A road safety management investigation model was created, based on several “good practice” criteria. Road safety management systems have been thoroughly investigated

  7. Plutonium finishing plant safety systems and equipment list

    International Nuclear Information System (INIS)

    Bergquist, G.G.

    1995-01-01

    The Safety Equipment List (SEL) supports Analysis Report (FSAR), WHC-SD-CP-SAR-021 and the Plutonium Finishing Plant Operational Safety Requirements (OSRs), WHC-SD-CP-OSR-010. The SEL is a breakdown and classification of all Safety Class 1, 2, and 3 equipment, components, or system at the Plutonium Finishing Plant complex

  8. Plutonium finishing plant safety systems and equipment list

    Energy Technology Data Exchange (ETDEWEB)

    Bergquist, G.G.

    1995-01-06

    The Safety Equipment List (SEL) supports Analysis Report (FSAR), WHC-SD-CP-SAR-021 and the Plutonium Finishing Plant Operational Safety Requirements (OSRs), WHC-SD-CP-OSR-010. The SEL is a breakdown and classification of all Safety Class 1, 2, and 3 equipment, components, or system at the Plutonium Finishing Plant complex.

  9. Intrauterine radiation exposures and mental retardation

    International Nuclear Information System (INIS)

    Miller, R.W.

    1988-01-01

    Small head size and mental retardation have been known as effects of intrauterine exposure to ionizing radiation since the 1920s. In the 1950s, studies of Japanese atomic-bomb survivors revealed that at 4-17 wk of gestation, the greater the dose, the smaller the brain (and head size), and that beginning at 0.5 Gy (50 rad) in Hiroshima, mental retardation increased in frequency with increasing dose. No other excess of birth defects was observed. Otake and Schull (1984) pointed out that the period of susceptibility to mental retardation coincided with that for proliferation and migration of neuronal elements from near the cerebral ventricles to the cortex. Mental retardation could be the result of interference with this process. Their analysis indicated that exposures at 8-15 wk to 0.01-0.02 Gy (1-2 rad) doubled the frequency of severe mental retardation. This estimate was based on small numbers of mentally retarded atomic-bomb survivors. Although nuclear accidents have occurred recently, new cases will hopefully be too rare to provide further information about the risk of mental retardation. It may be possible, however, to learn about lesser impairment. New psychometric tests may be helpful in detecting subtle deficits in intelligence or neurodevelopmental function. One such test is PEERAMID, which is being used in schools to identify learning disabilities due, for example, to deficits in attention, short- or long-term memory, or in sequencing information. This and other tests could be applied in evaluating survivors of intrauterine exposure to various doses of ionizing radiation. The results could change our understanding of the safety of low-dose exposures

  10. Intrauterine radiation exposures and mental retardation

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.W.

    1988-08-01

    Small head size and mental retardation have been known as effects of intrauterine exposure to ionizing radiation since the 1920s. In the 1950s, studies of Japanese atomic-bomb survivors revealed that at 4-17 wk of gestation, the greater the dose, the smaller the brain (and head size), and that beginning at 0.5 Gy (50 rad) in Hiroshima, mental retardation increased in frequency with increasing dose. No other excess of birth defects was observed. Otake and Schull (1984) pointed out that the period of susceptibility to mental retardation coincided with that for proliferation and migration of neuronal elements from near the cerebral ventricles to the cortex. Mental retardation could be the result of interference with this process. Their analysis indicated that exposures at 8-15 wk to 0.01-0.02 Gy (1-2 rad) doubled the frequency of severe mental retardation. This estimate was based on small numbers of mentally retarded atomic-bomb survivors. Although nuclear accidents have occurred recently, new cases will hopefully be too rare to provide further information about the risk of mental retardation. It may be possible, however, to learn about lesser impairment. New psychometric tests may be helpful in detecting subtle deficits in intelligence or neurodevelopmental function. One such test is PEERAMID, which is being used in schools to identify learning disabilities due, for example, to deficits in attention, short- or long-term memory, or in sequencing information. This and other tests could be applied in evaluating survivors of intrauterine exposure to various doses of ionizing radiation. The results could change our understanding of the safety of low-dose exposures.

  11. Development of a safety parameter supervision system for Angra-1

    International Nuclear Information System (INIS)

    Silva, R.A. da; Thome Filho, Z.D.; Schirru, R.; Martinez, A.S.; Oliveira, L.F.S. de

    1986-01-01

    The Safety Parameter Supervision System (SSPS) which is a computerized system for monitoring essential parameters in real time, determining the safety status and emergency procedures for returning normal reactor operation, in case of an anomaly occurrence, is presented. The SSPS consists of three sub-systems: Integrated parameter monitoring system which gives to operators an integrated vision of values of a parameter set, able to detect any deviation of normal reactor operation; safety critical function system which evaluates safety status in terms of a safety critical function set appointed in advance, and in case of violation of any critical function, it initiates the adequate emergency procedure to return normal operation; and safety parameter computer system which carries out the arquirement of analogic and digital control signals of nuclear power plant. (M.C.K.) [pt

  12. Intrauterine Devices Penetrated and Migrated: CT Findings

    International Nuclear Information System (INIS)

    Mejia Restrepo, Jorge; Lopez, Juan Esteban; Aldana Sepulveda, Natalia; Ruiz Zabaleta, Tania; Mazzaro Mauricio

    2011-01-01

    Intrauterine devices have been used for over 40 years, and they constitute the most widely accepted method of contraception among women because of the low rates of complications and low cost. Although uncommon, with the growing use of multidetector CT penetrated and migrated intrauterine devices have become a more common incidental finding. In some cases, intrauterine devices migrate to adjacent viscera, in particular the bladder and bowel and may give rise to symptoms. Consequently tomographic localization and characterization are essential for treatment planning.

  13. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  14. System theory and safety models in Swedish, UK, Dutch and Australian road safety strategies.

    Science.gov (United States)

    Hughes, B P; Anund, A; Falkmer, T

    2015-01-01

    Road safety strategies represent interventions on a complex social technical system level. An understanding of a theoretical basis and description is required for strategies to be structured and developed. Road safety strategies are described as systems, but have not been related to the theory, principles and basis by which systems have been developed and analysed. Recently, road safety strategies, which have been employed for many years in different countries, have moved to a 'vision zero', or 'safe system' style. The aim of this study was to analyse the successful Swedish, United Kingdom and Dutch road safety strategies against the older, and newer, Australian road safety strategies, with respect to their foundations in system theory and safety models. Analysis of the strategies against these foundations could indicate potential improvements. The content of four modern cases of road safety strategy was compared against each other, reviewed against scientific systems theory and reviewed against types of safety model. The strategies contained substantial similarities, but were different in terms of fundamental constructs and principles, with limited theoretical basis. The results indicate that the modern strategies do not include essential aspects of systems theory that describe relationships and interdependencies between key components. The description of these strategies as systems is therefore not well founded and deserves further development. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Safety climate and culture: Integrating psychological and systems perspectives.

    Science.gov (United States)

    Casey, Tristan; Griffin, Mark A; Flatau Harrison, Huw; Neal, Andrew

    2017-07-01

    Safety climate research has reached a mature stage of development, with a number of meta-analyses demonstrating the link between safety climate and safety outcomes. More recently, there has been interest from systems theorists in integrating the concept of safety culture and to a lesser extent, safety climate into systems-based models of organizational safety. Such models represent a theoretical and practical development of the safety climate concept by positioning climate as part of a dynamic work system in which perceptions of safety act to constrain and shape employee behavior. We propose safety climate and safety culture constitute part of the enabling capitals through which organizations build safety capability. We discuss how organizations can deploy different configurations of enabling capital to exert control over work systems and maintain safe and productive performance. We outline 4 key strategies through which organizations to reconcile the system control problems of promotion versus prevention, and stability versus flexibility. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Intravesical migration of an intrauterine device.

    Science.gov (United States)

    Gyasi-Sarpong, Christian Kofi; Maison, Patrick Opoku Manu; Morhe, Emmanuel; Aboah, Ken; Appiah, Kwaku Addai-Arhin; Azorliade, Roland; Baah-Nyamekye, Kofi; Otu-Boateng, Kwaku; Amoah, George; Antwi, Isaac; Frimpong-Twumasi, Benjamin; Arthur, Douglas

    2016-01-02

    Intrauterine contraceptive device is the most common method of reversible contraception in women. The intrauterine contraceptive device can perforate the uterus and can also migrate into pelvic or abdominal organs. Perforation of the urinary bladder by an intrauterine contraceptive device is not common. In West Africa, intravesical migration of an intrauterine contraceptive device has been rarely reported. In this report, we present a case of an intrauterine contraceptive device migration into the urinary bladder of a 33 year old African woman at the Komfo Anokye Teaching Hospital, Kumasi, Ghana. A 33 year old African woman presented with persistent urinary tract infection of 7 months duration despite appropriate antibiotic treatments. An abdominal ultrasonography revealed a urinary bladder calculus which was found to be an intrauterine contraceptive device on removal at cystoscopy. She got pregnant whilst having the intrauterine contraceptive device in place and delivered at term. The presence of recurrent or persistent urinary tract infection in any woman with an intrauterine contraceptive device should raise the suspicion of intravesical migration of the intrauterine contraceptive device.

  17. Safety regulations concerning instrumentation and control systems for research reactors

    International Nuclear Information System (INIS)

    El-Shanshoury, A.I.

    2009-01-01

    A brief study on the safety and reliability issues related to instrumentation and control systems in nuclear reactor plants is performed. In response, technical and strategic issues are used to accomplish instrumentation and control systems safety. For technical issues there are ; systems aspects of digital I and C technology, software quality assurance, common-mode software, failure potential, safety and reliability assessment methods, and human factors and human machine interfaces. The strategic issues are the case-by-case licensing process and the adequacy of the technical infrastructure. The purpose of this work was to review the reliability of the safety systems related to these technical issues for research reactors

  18. Automated Safety Incident Surveillance and Tracking System (ASISTS)

    Data.gov (United States)

    Department of Veterans Affairs — The Automated Safety Incident Surveillance and Tracking System (ASISTS) is a repository of Veterans Health Administration (VHA) employee accident data. Many types of...

  19. Analyzing Software Requirements Errors in Safety-Critical, Embedded Systems

    Science.gov (United States)

    Lutz, Robyn R.

    1993-01-01

    This paper analyzes the root causes of safety-related software errors in safety-critical, embedded systems. The results show that software errors identified as potentially hazardous to the system tend to be produced by different error mechanisms than non- safety-related software errors. Safety-related software errors are shown to arise most commonly from (1) discrepancies between the documented requirements specifications and the requirements needed for correct functioning of the system and (2) misunderstandings of the software's interface with the rest of the system. The paper uses these results to identify methods by which requirements errors can be prevented. The goal is to reduce safety-related software errors and to enhance the safety of complex, embedded systems.

  20. Qualification of FPGA-Based Safety-Related PRM System

    International Nuclear Information System (INIS)

    Miyazaki, Tadashi; Oda, Naotaka; Goto, Yasushi; Hayashi, Toshifumi

    2011-01-01

    Toshiba has developed Non-rewritable (NRW) Field Programmable Gate Array (FPGA)-based safety-related Instrumentation and Control (I and C) system. Considering application to safety-related systems, nonvolatile and non-rewritable FPGA which is impossible to be changed after once manufactured has been adopted in Toshiba FPGA-based system. FPGA is a device which consists only of basic logic circuits, and FPGA performs defined processing which is configured by connecting the basic logic circuit inside the FPGA. FPGA-based system solves issues existing both in the conventional systems operated by analog circuits (analog-based system) and the systems operated by central processing unit (CPU-based system). The advantages of applying FPGA are to keep the long-life supply of products, improving testability (verification), and to reduce the drift which may occur in analog-based system. The system which Toshiba developed this time is Power Range Neutron Monitor (PRM). Toshiba is planning to expand application of FPGA-based technology by adopting this development process to the other safety-related systems such as RPS from now on. Toshiba developed a special design process for NRW-FPGA-based safety-related I and C systems. The design process resolves issues for many years regarding testability of the digital system for nuclear safety application. Thus, Toshiba NRW-FPGA-based safety-related I and C systems has much advantage to be a would standard of the digital systems for nuclear safety application. (author)

  1. Interdisciplinary Traffic Safety Instructional System: Series I.

    Science.gov (United States)

    Maryland State Dept. of Education, Baltimore.

    Intended to train first grade students in safe conduct on the school bus, on bicycles, in an auto and in the school environment and to develop the perceptual skills they need as pedestrians, this curriculum provides directions and materials for approximately 150 safety learning activities. Safety concepts and skills are taught through activities…

  2. Safety Review related to Commercial Grade Digital Equipment in Safety System

    International Nuclear Information System (INIS)

    Yu, Yeongjin; Park, Hyunshin; Yu, Yeongjin; Lee, Jaeheung

    2013-01-01

    The upgrades or replacement of I and C systems on safety system typically involve digital equipment developed in accordance with non-nuclear standards. However, the use of commercial grade digital equipment could include the vulnerability for software common-mode failure, electromagnetic interference and unanticipated problems. Although guidelines and standards for dedication methods of commercial grade digital equipment are provided, there are some difficulties to apply the methods to commercial grade digital equipment for safety system. This paper focuses on regulatory guidelines and relevant documents for commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. This paper focuses on KINS regulatory guides and relevant documents for dedication of commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. Dedication including critical characteristics is required to use the commercial grade digital equipment on safety system in accordance with KEPIC ENB 6370 and EPRI TR-106439. The dedication process should be controlled in a configuration management process. Appropriate methods, criteria and evaluation result should be provided to verify acceptability of the commercial digital equipment used for safety function

  3. Design an optimum safety policy for personnel safety management - A system dynamic approach

    International Nuclear Information System (INIS)

    Balaji, P.

    2014-01-01

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making

  4. Design an optimum safety policy for personnel safety management - A system dynamic approach

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, P. [The Glocal University, Mirzapur Pole, Delhi- Yamuntori Highway, Saharanpur 2470001 (India)

    2014-10-06

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.

  5. Design an optimum safety policy for personnel safety management - A system dynamic approach

    Science.gov (United States)

    Balaji, P.

    2014-10-01

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.

  6. System and safety studies of accelerator driven transmutation systems

    Energy Technology Data Exchange (ETDEWEB)

    Gudowski, W.; Wallenius, J.; Tucek, K.; Eriksson, Marcus; Carlsson, Johan; Seltborg, P.; Cetnar, J. [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Nuclear and Reactor Physics

    2001-05-01

    The research on safety of Accelerator-Driven Transmutation Systems (ADS) at the department has been focused on: a) ADS core design and development of advanced nuclear fuel optimised for high transmutation rates and good safety features; b) analysis of ADS-dynamics c) computer code and nuclear data development relevant for simulation and optimization of ADS; d) participation in ADS experiments including 1 MW spallation target manufacturing, subcritical experiments MUSE (CEA-Cadarache). Moreover, during the reporting period the EU-project 'IABAT', co-ordinated by the department has been finished and 4 other projects have been initiated in the frame of the 5th European Framework Programme. Most of the research topics reported in this paper are referred to appendices, which have been published in the open literature. The topics, which are not yet published, are described here in more details.

  7. System and safety studies of accelerator driven transmutation systems

    International Nuclear Information System (INIS)

    Gudowski, W.; Wallenius, J.; Tucek, K.; Eriksson, Marcus; Carlsson, Johan; Seltborg, P.; Cetnar, J.

    2001-05-01

    The research on safety of Accelerator-Driven Transmutation Systems (ADS) at the department has been focused on: a) ADS core design and development of advanced nuclear fuel optimised for high transmutation rates and good safety features; b) analysis of ADS-dynamics c) computer code and nuclear data development relevant for simulation and optimization of ADS; d) participation in ADS experiments including 1 MW spallation target manufacturing, subcritical experiments MUSE (CEA-Cadarache). Moreover, during the reporting period the EU-project 'IABAT', co-ordinated by the department has been finished and 4 other projects have been initiated in the frame of the 5th European Framework Programme. Most of the research topics reported in this paper are referred to appendices, which have been published in the open literature. The topics, which are not yet published, are described here in more details

  8. Safety applications of computer based systems for the process industry

    International Nuclear Information System (INIS)

    Bologna, Sandro; Picciolo, Giovanni; Taylor, Robert

    1997-11-01

    Computer based systems, generally referred to as Programmable Electronic Systems (PESs) are being increasingly used in the process industry, also to perform safety functions. The process industry as they intend in this document includes, but is not limited to, chemicals, oil and gas production, oil refining and power generation. Starting in the early 1970's the wide application possibilities and the related development problems of such systems were recognized. Since then, many guidelines and standards have been developed to direct and regulate the application of computers to perform safety functions (EWICS-TC7, IEC, ISA). Lessons learnt in the last twenty years can be summarised as follows: safety is a cultural issue; safety is a management issue; safety is an engineering issue. In particular, safety systems can only be properly addressed in the overall system context. No single method can be considered sufficient to achieve the safety features required in many safety applications. Good safety engineering approach has to address not only hardware and software problems in isolation but also their interfaces and man-machine interface problems. Finally, the economic and industrial aspects of the safety applications and development of PESs in process plants are evidenced throughout all the Report. Scope of the Report is to contribute to the development of an adequate awareness of these problems and to illustrate technical solutions applied or being developed

  9. The regulatory system of nuclear safety in Russia

    International Nuclear Information System (INIS)

    Mizoguchi, Shuhei

    2013-01-01

    This article explains what type of mechanism the nuclear system has and how nuclear safety is regulated in Russia. There are two main organizations in this system : ROSATOM and ROSTEKHADZOR. ROSATOM, which was founded in 2007, incorporates all the nuclear industries in Russia, including civil nuclear companies as well as nuclear weapons complex facilities. ROSTEKHNADZOR is the federal body that secures and supervises the safety in using atomic energy. This article also reviews three laws on regulating nuclear safety. (author)

  10. Safety management systems and their role in achieving high standards of operational safety

    International Nuclear Information System (INIS)

    Coulston, D.J.; Baylis, C.C.

    2000-01-01

    Achieving high standards of operational safety requires a robust management framework that is visible to all personnel with responsibility for its implementation. The structure of the management framework must ensure that all processes used to manage safety interlink in a logical and coherent manner, that is, they form a management system that leads to continuous improvement in safety performance. This Paper describes BNFL's safety management system (SMS). The SMS has management processes grouped within 5 main elements: 1. Policy, 2. Organisation, 3. Planning and Implementation, 4. Measuring and Reviewing Performance, 5. Audit. These elements reflect the overall process of setting safety objective (from Policy), measuring success and reviewing the performance. Effective implementation of the SMS requires senior managers to demonstrate leadership through their commitment and accountability. However, the SMS as a whole reflects that every employee at every level within BNFL is responsible for safety of operations under their control. The SMS therefore promotes a proactive safety culture and safe operations. The system is formally documented in the Company's Environmental, Health and Safety (EHS) Manual. Within in BNFL Group, the Company structures enables the Manual to provide overall SMS guidance and co-ordination to its range of nuclear businesses. Each business develops the SMS to be appropriate at all levels of its organisation, but ensuring that each level is consistent with the higher level. The Paper concludes with a summary of BNFL's safety performance. (author)

  11. Efficacy of Intrauterine Device in the Treatment of Intrauterine Adhesions

    Science.gov (United States)

    Salma, Umme; Xue, Min; Md Sayed, Ali Sheikh; Xu, Dabao

    2014-01-01

    The primary purpose of this paper is to assess the efficacy of the use of the intrauterine device (IUD) as an adjunctive treatment modality, for intrauterine adhesions (IUAs). All eligible literatures were identified by electronic databases including PubMed, Scopus, and Web of Science. Additional relevant articles were identified from citations in these publications. There were 28 studies included for a systematic review. Of these, 5 studies were eligible for meta-analysis and 23 for qualitative assessment only. Twenty-eight studies related to the use of IUDs as ancillary treatment following adhesiolysis were identified. Of these studies, 25 studies at least one of the following methods were carried out as ancillary treatment: Foley catheter, hyaluronic acid gel, hormonal therapy, or amnion graft in addition to the IUD. There was one study that used IUD therapy as a single ancillary treatment. In 2 studies, no adjunctive therapy was used after adhesiolysis. There was a wide range of reported menstrual and fertility outcomes which were associated with the use of IUD combined with other ancillary treatments. At present, the IUD is beneficial in patients with IUA, regardless of stage of adhesions. However, IUD needs to be combined with other ancillary treatments to obtain maximal outcomes, in particular in patients with moderate to severe IUA. PMID:25254212

  12. Efficacy of Intrauterine Device in the Treatment of Intrauterine Adhesions

    Directory of Open Access Journals (Sweden)

    Umme Salma

    2014-01-01

    Full Text Available The primary purpose of this paper is to assess the efficacy of the use of the intrauterine device (IUD as an adjunctive treatment modality, for intrauterine adhesions (IUAs. All eligible literatures were identified by electronic databases including PubMed, Scopus, and Web of Science. Additional relevant articles were identified from citations in these publications. There were 28 studies included for a systematic review. Of these, 5 studies were eligible for meta-analysis and 23 for qualitative assessment only. Twenty-eight studies related to the use of IUDs as ancillary treatment following adhesiolysis were identified. Of these studies, 25 studies at least one of the following methods were carried out as ancillary treatment: Foley catheter, hyaluronic acid gel, hormonal therapy, or amnion graft in addition to the IUD. There was one study that used IUD therapy as a single ancillary treatment. In 2 studies, no adjunctive therapy was used after adhesiolysis. There was a wide range of reported menstrual and fertility outcomes which were associated with the use of IUD combined with other ancillary treatments. At present, the IUD is beneficial in patients with IUA, regardless of stage of adhesions. However, IUD needs to be combined with other ancillary treatments to obtain maximal outcomes, in particular in patients with moderate to severe IUA.

  13. Food safety performance indicators to benchmark food safety output of food safety management systems

    NARCIS (Netherlands)

    Jacxsens, L.; Uyttendaele, M.; Devlieghere, F.; Rovira, J.; Oses Gomez, S.; Luning, P.A.

    2010-01-01

    There is a need to measure the food safety performance in the agri-food chain without performing actual microbiological analysis. A food safety performance diagnosis, based on seven indicators and corresponding assessment grids have been developed and validated in nine European food businesses.

  14. A concurrent diagnosis of microbiological food safety output and food safety management system performance: Cases from meat processing industries

    NARCIS (Netherlands)

    Luning, P.A.; Jacxsens, L.; Rovira, J.; Oses Gomez, S.; Uyttendaele, M.; Marcelis, W.J.

    2011-01-01

    Stakeholder requirements force companies to analyse their food safety management system (FSMS) performance to improve food safety. Performance is commonly analysed by checking compliance against preset requirements via audits/inspections, or actual food safety (FS) output is analysed by

  15. Towards predictive cardiovascular safety : a systems pharmacology approach

    NARCIS (Netherlands)

    Snelder, Nelleke

    2014-01-01

    Cardiovascular safety issues related to changes in blood pressure, arise frequently in drug development. In the thesis “Towards predictive cardiovascular safety – a systems pharmacology approach”, a system-specific model is described to quantify drug effects on the interrelationship between mean

  16. 49 CFR 659.19 - System safety program plan: contents.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false System safety program plan: contents. 659.19 Section 659.19 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL TRANSIT ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the...

  17. 49 CFR 659.15 - System safety program standard.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false System safety program standard. 659.15 Section 659.15 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL TRANSIT ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the...

  18. Software for the occupational health and safety integrated management system

    International Nuclear Information System (INIS)

    Vătăsescu, Mihaela

    2015-01-01

    This paper intends to present the design and the production of a software for the Occupational Health and Safety Integrated Management System with the view to a rapid drawing up of the system documents in the field of occupational health and safety

  19. 14 CFR 415.129 - Flight safety system test data.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety system test data. 415.129 Section 415.129 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION... Launch Vehicle From a Non-Federal Launch Site § 415.129 Flight safety system test data. (a) General. An...

  20. Emerging standards with application to accelerator safety systems

    International Nuclear Information System (INIS)

    Mahoney, K.L.; Robertson, H.P.

    1997-01-01

    This paper addresses international standards which can be applied to the requirements for accelerator personnel safety systems. Particular emphasis is given to standards which specify requirements for safety interlock systems which employ programmable electronic subsystems. The work draws on methodologies currently under development for the medical, process control, and nuclear industries

  1. Software for the occupational health and safety integrated management system

    Energy Technology Data Exchange (ETDEWEB)

    Vătăsescu, Mihaela [University Politehnica Timisoara, Department of Engineering and Management, 5 Revolutiei street, 331128 Hunedoara (Romania)

    2015-03-10

    This paper intends to present the design and the production of a software for the Occupational Health and Safety Integrated Management System with the view to a rapid drawing up of the system documents in the field of occupational health and safety.

  2. New Automated System Available for Reporting Safety Concerns | Poster

    Science.gov (United States)

    A new system has been developed for reporting safety issues in the workplace. The Environment, Health, and Safety’s (EHS’) Safety Inspection and Issue Management System (SIIMS) is an online resource where any employee can report a problem or issue, said Siobhan Tierney, program manager at EHS.

  3. Laparoscopic Retrieval Of Perforated Intrauterine Device ...

    African Journals Online (AJOL)

    We present a case of successful laparoscopic retrieval of a perforated intrauterine device (Lippes loop). The Lippes loop was inserted after manual intrauterine adhesiolysis as a treatment of uterine synaechia presenting as secondary amenorrhoea of 20 months duration. The uterine perforation in this patient did not occur at ...

  4. Successful Intrauterine Pregnancy following salpingostomy; Case ...

    African Journals Online (AJOL)

    by salpingostomy, after which she had spontaneous abortion of the associated intrauterine pregnancy. Result: Initial marital disharmony, followed by an uneventful intrauterine pregnancy carried to term with caesarean delivery of a live female baby. Conclusion: In well-selected cases, conservative tubal surgeries should be ...

  5. The reliability of nuclear power plant safety systems

    International Nuclear Information System (INIS)

    Susnik, J.

    1978-01-01

    A criterion was established concerning the protection that nuclear power plant (NPP) safety systems should afford. An estimate of the necessary or adequate reliability of the total complex of safety systems was derived. The acceptable unreliability of auxiliary safety systems is given, provided the reliability built into the specific NPP safety systems (ECCS, Containment) is to be fully utilized. A criterion for the acceptable unreliability of safety (sub)systems which occur in minimum cut sets having three or more components of the analysed fault tree was proposed. A set of input MTBF or MTTF values which fulfil all the set criteria and attain the appropriate overall reliability was derived. The sensitivity of results to input reliability data values was estimated. Numerical reliability evaluations were evaluated by the programs POTI, KOMBI and particularly URSULA, the last being based on Vesely's kinetic fault tree theory. (author)

  6. SBO simulations for Integrated Passive Safety System (IPSS) using MARS

    International Nuclear Information System (INIS)

    Kim, Sang Ho; Jeong, Sung Yeop; Chang, Soon Heung

    2012-01-01

    The current nuclear power plants have lots of active safety systems with some passive safety systems. The safety of current and future nuclear power plants can be enhanced by the application of additional passive safety systems for the ultimate safety. It is helpful to install the passive safety systems on current nuclear power plants without the design change for the licensibility. For solving the problem about the system complexity shown in the Fukushima accidents, the current nuclear power plants are needed to be enhanced by an additional integrated and simplified system. As a previous research, the integrated passive safety system (IPSS) was proposed to solve the safety issues related with the decay heat removal, containment integrity and radiation release. It could be operated by natural phenomena like gravity, natural circulation and pressure difference without AC power. The five main functions of IPSS are: (a) Passive decay heat removal, (b) Passive emergency core cooling, (c) Passive containment cooling, (d) Passive in vessel retention and ex-vessel cooling, and (e) Filtered venting and pressure control. The purpose of this research is to analyze the performances of each function by using MARS code. The simulated accident scenarios were station black out (SBO) and the additional accidents accompanied by SBO

  7. Effects of intrauterine retention and postmortem interval on body weight following intrauterine death: implications for assessment of fetal growth restriction at autopsy.

    Science.gov (United States)

    Man, J; Hutchinson, J C; Ashworth, M; Heazell, A E; Levine, S; Sebire, N J

    2016-11-01

    According to the classification system used, 15-60% of stillbirths remain unexplained, despite undergoing recommended autopsy examination, with variable attribution of fetal growth restriction (FGR) as a cause of death. Distinguishing small-for-gestational age (SGA) from pathological FGR is a challenge at postmortem examination. This study uses data from a large, well-characterized series of intrauterine death autopsies to investigate the effects of secondary changes such as fetal maceration, intrauterine retention and postmortem interval on body weight. Autopsy findings from intrauterine death investigations (2005-2013 inclusive, from Great Ormond Street Hospital and St George's Hospital, London) were collated into a research database. Growth charts published by the World Health Organization were used to determine normal expected weight centiles for fetuses born ≥ 24 weeks' gestation, and the effects of intrauterine retention (maceration) and postmortem interval were calculated. There were 1064 intrauterine deaths, including 533 stillbirths ≥ 24 weeks' gestation with a recorded birth weight. Of these, 192 (36%) had an unadjusted birth weight below the 10 th centile and were defined as SGA. The majority (86%) of stillborn SGA fetuses demonstrated some degree of maceration, indicating a significant period of intrauterine retention after death. A significantly greater proportion of macerated fetuses were present in the SGA population compared with the non-SGA population (P = 0.01). There was a significant relationship between increasing intrauterine retention interval and both more severe maceration and reduction in birth weight (P autopsy and, as postmortem interval increased, fetal weight loss increased (P = 0.0001). Based on birth weight alone, 36% of stillbirths are classified as SGA. However, fetuses lose weight in utero with increasing intrauterine retention and continue to lose weight between delivery and autopsy, resulting in erroneous overestimation of

  8. Control, Operator Support and Safety System of PVC-reactors

    Directory of Open Access Journals (Sweden)

    Jens I. Ytreeide

    1997-01-01

    Full Text Available In modern petrochemical plants the corporate and societal demands to plant safety and minimum environmental effects are high. These demands rise high performance requirements to the technical systems, specially the process control and safety systems including an effective operator support system with fault detection capability. The systems must have high reliability also against erroneous operations which may cause shutdown situations or quality deviations.

  9. The complexity of patient safety reporting systems in UK dentistry.

    Science.gov (United States)

    Renton, T; Master, S

    2016-10-21

    Since the 'Francis Report', UK regulation focusing on patient safety has significantly changed. Healthcare workers are increasingly involved in NHS England patient safety initiatives aimed at improving reporting and learning from patient safety incidents (PSIs). Unfortunately, dentistry remains 'isolated' from these main events and continues to have a poor record for reporting and learning from PSIs and other events, thus limiting improvement of patient safety in dentistry. The reasons for this situation are complex.This paper provides a review of the complexities of the existing systems and procedures in relation to patient safety in dentistry. It highlights the conflicting advice which is available and which further complicates an overly burdensome process. Recommendations are made to address these problems with systems and procedures supporting patient safety development in dentistry.

  10. Design requirements of communication architecture of SMART safety system

    International Nuclear Information System (INIS)

    Park, H. Y.; Kim, D. H.; Sin, Y. C.; Lee, J. Y.

    2001-01-01

    To develop the communication network architecture of safety system of SMART, the evaluation elements for reliability and performance factors are extracted from commercial networks and classified the required-level by importance. A predictable determinacy, status and fixed based architecture, separation and isolation from other systems, high reliability, verification and validation are introduced as the essential requirements of safety system communication network. Based on the suggested requirements, optical cable, star topology, synchronous transmission, point-to-point physical link, connection-oriented logical link, MAC (medium access control) with fixed allocation are selected as the design elements. The proposed architecture will be applied as basic communication network architecture of SMART safety system

  11. Development of the Advanced Nuclear Safety Information Management (ANSIM) System

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Jae Min; Ko, Young Cheol; Song, Tai Gil [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Korea has become a technically independent nuclear country and has grown into an exporter of nuclear technologies. Thus, nuclear facilities are increasing in significance at KAERI (Korea Atomic Energy Research Institute), and it is time to address the nuclear safety. The importance of nuclear safety cannot be overemphasized. Therefore, a management system is needed urgently to manage the safety of nuclear facilities and to enhance the efficiency of nuclear information. We have established ISP (Information Strategy Planning) for the Integrated Information System of nuclear facility and safety management. The purpose of this paper is to develop a management system for nuclear safety. Therefore, we developed the Advanced Nuclear Safety Information Management system (hereinafter referred to as the 'ANSIM system'). The ANSIM system has been designed and implemented to computerize nuclear safety information for standardization, integration, and sharing in real-time. Figure 1 shows the main home page of the ANSIM system. In this paper, we describe the design requirements, contents, configurations, and utilizations of the ANSIM system

  12. Safety system for moving coil pressure algometer.

    Science.gov (United States)

    Adnadjevic, Djordje; Lorrain, Thomas; Graven-Nielsen, Thomas

    2013-01-01

    The threat of safety failure during use of potent actuators is a known problem. The use of such actuators in the field of pressure algometry requires adaptation of safety measures since stimulation is applied to human beings. This design provides an additional safety level required in the field of computer-controlled pressure algometry but in principle its usage is not restricted just to this area. The fuse consists of four parts (inner cylinder, outer cylinder lid, outer cylinder guide, and the gauge screw) which are simple and cheap to manufacture, easy to reassemble once the fuse has been triggered, and gaugeable with commercially available tools. The prototype showed acceptable levels of performance given the intended usage of the stimulation setup, namely increasing and repeated musculoskeletal stimulation. Repeatable range of holding force has been attained for the particular application against a rubber mat surface mimicking musculoskeletal tissue (96% for forces F < 20 kg, and 30% for forces 25 kg < F ≤ 35 kg).

  13. A fuzzy decision-support system in road safety planning

    OpenAIRE

    Behnood, Hamid Reza; Ayati, Esmaeel; Brijs, Tom; Neghab, Mohammadali Pirayesh; Shen, Yongjun

    2017-01-01

    The objective of this research was to develop a decision-support system to help road safety policy makers make the right choices in road safety planning based on the efficiency of previously implemented safety measures. The measures considered for each region in the study include performance indicators about police operations, treated black spots, freeway and highway facility supplies, speed control cameras, emergency medical services and road lighting projects. To this end, an inefficiency m...

  14. Tank waste remediation system nuclear criticality safety program management review

    International Nuclear Information System (INIS)

    BRADY RAAP, M.C.

    1999-01-01

    This document provides the results of an internal management review of the Tank Waste Remediation System (TWRS) criticality safety program, performed in advance of the DOE/RL assessment for closure of the TWRS Nuclear Criticality Safety Issue, March 1994. Resolution of the safety issue was identified as Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-40-12, due September 1999

  15. Safety study of PCC 2140 and ALILOG 21 used as part of safety measurement systems

    International Nuclear Information System (INIS)

    Meriaux, Pierre; Adnot, Serge; Rayrolles, Catherine.

    1978-03-01

    The PCC 2140 and ALILOG 21 equipment may be used at C.E.A. or E.D.F., as part of safety measurement systems. In a study of a similar, but earlier equipment, it was noticed that certain types of failures caused the system to switch to the least sensitive measurement range, which was detrimental to safety. This report analyses failure modes leading to unsafe failures and evaluates the risks ran into taking in account tests during use [fr

  16. Safety evaluation of the KNICS digital reactor protection system

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Jang, Seung Cheol; Choi, Jong Gyun

    2005-01-01

    Korean Nuclear I and C System (KNICS) project, a national research program for developing a safety-class digital system, has designed a new reactor protection system (RPS). The usage of digital equipment in a safety critical application increases the importance of a risk evaluation since microprocessors and software technologies make the digital system very complex and their unavailability is hard to quantify. This paper addresses the safety evaluation of the KNICS RPS in consideration of the several technical concerns of a safety modeling for a digital system. We also present the fault-tree modeling technique and the risk evaluation results. A fault-tree model which includes the common cause failure events, the coverage of a fault-tolerant mechanism and the software failure event is developed. Based on the minimal cut sets of the model, we discuss the system unavailability of the newly developed design of the KNICS RPS

  17. Declarative Rule-based Safety for Robotic Perception Systems

    DEFF Research Database (Denmark)

    Mogensen, Johann Thor Ingibergsson; Kraft, Dirk; Schultz, Ulrik Pagh

    2017-01-01

    Mobile robots are used across many domains from personal care to agriculture. Working in dynamic open-ended environments puts high constraints on the robot perception system, which is critical for the safety of the system as a whole. To achieve the required safety levels the perception system needs...... to be certified, but no specific standards exist for computer vision systems, and the concept of safe vision systems remains largely unexplored. In this paper we present a novel domain-specific language that allows the programmer to express image quality detection rules for enforcing safety constraints....... The language allows developers to increase trustworthiness in the robot perception system, which we argue would increase compliance with safety standards. We demonstrate the usage of the language to improve reliability in a perception pipeline and evaluate it against manually written rules on embedded hardware...

  18. Agricultural machinery safety alert system using ultrasonic sensors.

    Science.gov (United States)

    Guo, L; Zhang, Q; Han, S

    2002-11-01

    This article introduces a conceptual safety alert system using ultrasonic sensors. The safety alert system was designed to detect moving objects in the vicinity of agricultural machinery. This system uses two ultrasonic sensors to detect the distances between the sensors and the moving object and a position detection algorithm to determine the moving object's position relative to the machinery. A stationary test bench was built to prove the concept of the safety sensing system. Validation tests in an outdoor environment indicated that the conceptual safety alert system was capable of detecting the position of a moving object in the vicinity of agricultural machinery in real time, and generating a timely warning signal to raise the attention of the operator for ensuring safe operations. This result proved that the conceptual system has tremendous potential for agricultural machinery applications.

  19. Safety and efficiency of future systems

    International Nuclear Information System (INIS)

    2000-01-01

    The objective of the program was to investigate and evaluate new or revised concepts for nuclear energy that offer potential long term benefits in terms of cost, safety, waste management, use of fissile material, less risk of diversion and sustainability. The work program was concerned with studying innovative or revised reactor concepts and other applications, and innovative fuels and fuel cycles

  20. Development and application of digital safety system in NPPs

    International Nuclear Information System (INIS)

    Kwon, Keechoon; Kim, Changhwoi; Lee, Dongyoung

    2012-01-01

    This paper describes the development of digital safety system in NPPs based on safety- grade programmable logic controller (PLC) platform and its application to real NPP construction. The digital safety system consists of a reactor protection system and an engineered safety feature-component control system. The safety-grade PLC platform was developed so that it meets the requirements of the regulation. The PLC consists of various modules such as a power module, a processor module, communication modules, digital input/output modules, analog input/output modules, a LOCA bus extension module, and a high-speed pulse counter module. The reactor protection system is designed with a redundant 4-channel architecture, and every channel is implemented with the same architecture. A single channel consists of a redundant bi-stable processor, a redundant coincidence processor, an automatic test and interface processor, and a cabinet operator module. The engineered safety feature-component control system is designed with four redundant divisions, and implemented with the PLC platform. The principal components of an individual division are fault tolerant group controllers, loop controllers, a test and interface processor, a cabinet operator module and a control channel gateway. The topical report is submitted to the regulatory body, and got safety evaluation report from the regulatory body. Also, the developed system is tested in the integrated performance validation facility. It is decided that the digital safety system applied to Shin-Uljin unit 1 and 2 after a topical report approval and validation test. Design changes occur in the digital safety system that is applied to an actual nuclear power plant construction, and the PLC has also been upgraded

  1. Development of main steam safety valve set pressure evaluating system

    International Nuclear Information System (INIS)

    Oketani, Koichiro; Manabe, Yoshihisa.

    1991-01-01

    A main steam safety valve set pressure test is conducted for all valves during every refueling outage in Japan's PWRs. Almost all operations of the test are manually conducted by a skilled worker. In order to obtain further reliability and reduce the test time, an automatic test system using a personnel computer has been developed in accordance with system concept. Quality assurance was investigated to fix system specifications. The prototype of the system was manufactured to confirm the system reliability. The results revealed that this system had high accuracy measurement and no adverse influence on the safety valve. This system was concluded to be applicable for actual use. (author)

  2. Safety parameter display system (SPDS) for Russian-designed NPPs

    International Nuclear Information System (INIS)

    Anikanov, S.S.; Catullo, W.J.; Pelusi, J.L.

    1997-01-01

    As part of the programs aimed at improving the safety of Russian-designed reactors, the US DoE has sponsored a project of providing a safety parameter display system (SPDS) for nuclear power plants with such reactors. The present paper is focused mostly on the system architecture design features of SPDS systems for WWER-1000 and RBMK-1000 reactors. The function and the operating modes of the SPDS are outlined, and a description of the display system is given. The system architecture and system design of both an integrated and a stand-alone IandC system is explained. (A.K.)

  3. Qualification of safety-critical software for digital reactor safety system in nuclear power plants

    International Nuclear Information System (INIS)

    Kwon, Kee-Choon; Park, Gee-Yong; Kim, Jang-Yeol; Lee, Jang-Soo

    2013-01-01

    This paper describes the software qualification activities for the safety-critical software of the digital reactor safety system in nuclear power plants. The main activities of the software qualification processes are the preparation of software planning documentations, verification and validation (V and V) of the software requirements specifications (SRS), software design specifications (SDS) and codes, and the testing of the integrated software and integrated system. Moreover, the software safety analysis and software configuration management are involved in the software qualification processes. The V and V procedure for SRS and SDS contains a technical evaluation, licensing suitability evaluation, inspection and traceability analysis, formal verification, software safety analysis, and an evaluation of the software configuration management. The V and V processes for the code are a traceability analysis, source code inspection, test case and test procedure generation. Testing is the major V and V activity of the software integration and system integration phases. The software safety analysis employs a hazard operability method and software fault tree analysis. The software configuration management in each software life cycle is performed by the use of a nuclear software configuration management tool. Through these activities, we can achieve the functionality, performance, reliability, and safety that are the major V and V objectives of the safety-critical software in nuclear power plants. (author)

  4. Report of safety of the characterizing system of radioactive waste

    International Nuclear Information System (INIS)

    Angeles C, A.; Jimenez D, J.; Reyes L, J.

    1998-09-01

    Report of safety of the system of radioactive waste of the ININ: Installation, participant personnel, selection of the place, description of the installation, equipment. Proposed activities: operations with radioactive material, calibration in energy, calibration in efficiency, types of waste. Maintenance: handling of radioactive waste, physical safety. Organization: radiological protection, armor-plating, personal dosemeter, risks and emergency plan, environmental impact, medical exams. (Author)

  5. Approaches to construction of systems of safety management in airlines

    Directory of Open Access Journals (Sweden)

    2015-01-01

    Full Text Available The article presents three approaches of building a safety management system (SMS in airlines in the framework of implementation of ICAO SARPs that apply methods of risk assessment based on use of operational activity of airline taking into account existing and implementing "protections" or "safety barriers".

  6. A management system integrating radiation protection and safety supporting safety culture in the hospital

    International Nuclear Information System (INIS)

    Almen, A.; Lundh, C.

    2015-01-01

    Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system. The main experience from developing a management system is that it is possible to create a vast number of common policies and routines for the whole hospital, resulting in a cost-efficient system. One of the key benefits is the involvement of management at all levels, including the hospital director. Furthermore, a transparent system will involve staff throughout the organisation as well. A management system supports a common view on what should be done, who should do it and how the activities are reviewed. An integrated management system for radiation protection and safety includes key elements supporting a safety culture. (authors)

  7. Safety design integrated in the building delivery system

    DEFF Research Database (Denmark)

    Jørgensen, Kirsten

    2013-01-01

    . The purpose of this article is to demonstrate how safety and health can be integrated in the design phases integrated in the management delivery systems within construction, The method for the research was to go through the building delivery system step by step and create a normative description of what, when...... and how to fully integrate safety in each part of the process. The result is a concept and guideline including control forms for how to integrate safety design in the Building Delivery System plus what to do and when. The concept has been tested in an educational context. The practical value...

  8. Study of system safety evaluation on LTO of national project. NISA safety research project on system safety of nuclear power plants

    International Nuclear Information System (INIS)

    Takizawa, Masayuki; Sekimura, Naoto; Miyano, Hiroshi; Aoyama, Katsunobu

    2012-01-01

    Japanese safety regulatory body, that is, Nuclear and Industrial Safety Agency (NISA) started a 5-year national safety research project as 'the first stage' from 2006 FY to 2010 FY whose objective is 'Improve the technical information basis in order to utilize knowledge as well as information related to ageing management and maintenance of NPPs. Fukushima disaster happened in March 2011, and the priority of research needs for ageing management dramatically changed in Japan. The second-stage national project started in October 2011 with the concept of 'system safety' of NNPs where not only ageing management on degradation phenomena of important components but also safety management on total plant systems are paid attention to. The second-stage project is so called 'Japanese Ageing Management Program for System Safety (JAMPSS)'. (author)

  9. Safety classification of nuclear power plant systems, structures and components

    International Nuclear Information System (INIS)

    1992-01-01

    The Safety Classification principles used for the systems, structures and components of a nuclear power plant are detailed in the guide. For classification, the nuclear power plant is divided into structural and operational units called systems. Every structure and component under control is included into some system. The Safety Classes are 1, 2 and 3 and the Class EYT (non-nuclear). Instructions how to assign each system, structure and component to an appropriate safety class are given in the guide. The guide applies to new nuclear power plants and to the safety classification of systems, structures and components designed for the refitting of old nuclear power plants. The classification principles and procedures applying to the classification document are also given

  10. A Reliability Assessment Method for the VHTR Safety Systems

    International Nuclear Information System (INIS)

    Lee, Hyung Sok; Jae, Moo Sung; Kim, Yong Wan

    2011-01-01

    The Passive safety system by very high temperature reactor which has attracted worldwide attention in the last century is the reliability safety system introduced for the improvement in the safety of the next generation nuclear power plant design. The Passive system functionality does not rely on an external source of energy, but on an intelligent use of the natural phenomena, such as gravity, conduction and radiation, which are always present. Because of these features, it is difficult to evaluate the passive safety on the risk analysis methodology having considered the existing active system failure. Therefore new reliability methodology has to be considered. In this study, the preliminary evaluation and conceptualization are tried, applying the concept of the load and capacity from the reliability physics model, designing the new passive system analysis methodology, and the trial applying to paper plant.

  11. Chronic Cervical Perforation by an Intrauterine Device

    Directory of Open Access Journals (Sweden)

    Semra Oruç Koltan

    2010-06-01

    Full Text Available The intrauterine device (IUD is a widely used, highly effective method of birth control. Uterine perforation is a rare yet serious complication and is usually seen during insertion of the IUD. A regular examination is necessary for follow-up. We present a patient with an IUD that had perforated the cervix. The diagnosis was made during routine gynecological examination, and the patient was treated in a timely manner before any complications such as ectopic pregnancy, intrauterine pregnancy, infection or irreversible harm to the cervix arose. This case stresses the importance of regular visits to maintain health and diagnose possible adverse effects of intrauterine contraceptive methods.

  12. Intrauterine neuromuscular blockade in fetus.

    Science.gov (United States)

    Fan, S Z; Huang, F Y; Lin, S Y; Wang, Y P; Hsieh, F J

    1990-03-01

    Antenatal intrauterine fetal therapy has now become the target of numerous invasive diagnostic and therapeutic maneuvers. Fetal motion during intrauterine fetal therapy not only makes these procedures technically more difficult but also increases the likelihood of trauma to the umbilical vessels and the fetus. Combination of high doses of sedatives, tranquilizers, and narcotics rarely results in adequate suppression of fetal movement. Such medication puts the mother at risk of respiratory depression, regurgitation and aspiration. The use of pancuronium or atracurium to temporarily arrest fetal movement in ten fetus is reported. After an initial ultrasound assessment of fetal lie, placental location, and umbilical cord insertion site, the fetal weight was calculated by the ultrasound parameters of biparietal diameter and abdominal circumference. Under ultrasound guidance, we injected pancuronium 0.15 mg/kg or atracurium 1.0 mg/kg using a 23-gauge spinal needle into the fetal gluteal muscle. Short-term paralysis of the fetus was induced in all cases. Fetal movement stopped by sonographic observation within 5.8 +/- 2.3 min in the pancuronium group and 4.7 +/- 1.8 min in the atracurium group. Fetal movements returned both to maternal sensation or ultrasonic observation by 92 +/- 23 min in the first group and 36 +/- 11 min in the second group. No adverse effect of the relaxant has been observed in any of the mothers. There was no evidence of local soft tissue, nerve or muscle damage at the site of injection on initial examination of the neonates after delivery. The use of neuromuscular relaxant in fetus was a safe and useful method.

  13. Safety of High Speed Magnetic Levitation Transportation Systems: Preliminary Safety Review of the Transrapid Maglev System

    Science.gov (United States)

    1990-11-01

    The safety of various magnetically levitated trains under development for possible : implementation in the United States is of direct concern to the Federal Railroad : Administration. This report, one in a series of planned reports on maglev safety, ...

  14. Nitrogen-system safety study: Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    1982-07-01

    The Department of Energy has primary responsibility for the safety of operations at DOE-owned nuclear facilities. The guidelines for the analysis of credible accidents are outlined in DOE Order 5481.1. DOE has requested that existing plant facilities and operations be reviewed for potential safety problems not covered by standard industrial safety procedures. This review is being conducted by investigating individual facilities and documenting the results in Safety Study Reports which will be compiled to form the Existing Plant Final Safety Analysis Report which is scheduled for completion in September, 1984. This Safety Study documents the review of the Plant Nitrogen System facilities and operations and consists of Section 4.0, Facility and Process Description, and Section 5.0, Accident Analysis, of the Final Safety Analysis Report format. The existing nitrogen system consists of a Superior Air Products Company Type D Nitrogen Plant, nitrogen storage facilities, vaporization facilities and a distribution system. The system is designed to generate and distribute nitrogen gas used in the cascade for seal feed, buffer systems, and for servicing equipment when exceptionally low dew points are required. Gaseous nitrogen is also distributed to various process auxiliary buildings. The average usage is approximately 130,000 standard cubic feet per day

  15. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  16. Safety inspections - the role of TS : risks, their assessment and the role of safety systems

    CERN Document Server

    Béjar-Alonso, Isabel; CERN. Geneva. TS Department

    2008-01-01

    In 2007 the DG decided a new approach for safety at CERN. This had as consequence the creation of a new unit, the safety service provider, in the TS department. The organization and the services that this unit provides to CERN will be described and the achievements since the creation of the unit will be summarized. Some important personnel safety systems, on their side have been the responsibility of the TS Department for many years. Their importance has grown with the arrival of LHC and their complexity and impact on operation has increased. Their role as well as the importance of an appropriate regulatory framework shall be discussed.

  17. The Danish patient safety experience: the Act on Patient Safety in the Danish Health care system

    DEFF Research Database (Denmark)

    Lundgaard, Mette; Rabøl, Louise; Jensen, Elisabeth Agnete Brøgger

    2005-01-01

    This paper describes the process that lead to the passing of the Act for Patient Safety in the Danisk health care sytem, the contents of the act and how the act is used in the Danish health care system. The act obligates frontline health care personnel to report adverse events, hospital owners...... to act on the reports and the National Board of Health to commuicate the learning nationally. The act protects health care providers from sanctions as a result of reporting. In January 2004, the Act on Patient Safety in the Danish health care system was put into force. In the first twelve months 5740...... adverse events were reported. the reports were analyzed locally (hospital and region), anonymized ad then sent to the National Board af Health. The Act on Patient Safety has driven the work with patient safety forward but there is room for improvement. Continuous and improved feedback from all parts...

  18. The Danish patient safety experience: the Act on Patient Safety in the Danish Health care system

    DEFF Research Database (Denmark)

    Lundgaard, Mette; Rabøl, Louise; Jensen, Elisabeth Agnete Brøgger

    2005-01-01

    adverse events were reported. the reports were analyzed locally (hospital and region), anonymized ad then sent to the National Board af Health. The Act on Patient Safety has driven the work with patient safety forward but there is room for improvement. Continuous and improved feedback from all parts......This paper describes the process that lead to the passing of the Act for Patient Safety in the Danisk health care sytem, the contents of the act and how the act is used in the Danish health care system. The act obligates frontline health care personnel to report adverse events, hospital owners...... to act on the reports and the National Board of Health to commuicate the learning nationally. The act protects health care providers from sanctions as a result of reporting. In January 2004, the Act on Patient Safety in the Danish health care system was put into force. In the first twelve months 5740...

  19. Analysis of Aviation Safety Reporting System Incident Data Associated With the Technical Challenges of the Vehicle Systems Safety Technology Project

    Science.gov (United States)

    Withrow, Colleen A.; Reveley, Mary S.

    2014-01-01

    This analysis was conducted to support the Vehicle Systems Safety Technology (VSST) Project of the Aviation Safety Program (AVsP) milestone VSST4.2.1.01, "Identification of VSST-Related Trends." In particular, this is a review of incident data from the NASA Aviation Safety Reporting System (ASRS). The following three VSST-related technical challenges (TCs) were the focus of the incidents searched in the ASRS database: (1) Vechicle health assurance, (2) Effective crew-system interactions and decisions in all conditions; and (3) Aircraft loss of control prevention, mitigation, and recovery.

  20. Reactivity requirements and safety systems for heavy water reactors

    International Nuclear Information System (INIS)

    Kati, S.L.; Rustagi, R.S.

    1977-01-01

    The natural uranium fuelled pressurised heavy water reactors are currently being installed in India. In the design of nuclear reactors, adequate attention has to be given to the safety systems. In recent years, several design modifications having bearing on safety, in the reactor processes, protective and containment systems have been made. These have resulted either from new trends in safety and reliability standards or as a result of feed-back from operating reactors of this type. The significant areas of modifications that have been introduced in the design of Indian PHWR's are: sophisticated theoretical modelling of reactor accidents, reactivity control, two independent fast acting systems, full double containment and improved post-accident depressurisation and building clean-up. This paper brings out the evolution of design of safety systems for heavy water reactors. A short review of safety systems which have been used in different heavy water reactors, of varying sizes, has been made. In particular, the safety systems selected for the latest 235 MWe twin reactor unit station in Narora, in Northern India, have been discussed in detail. Research and Development efforts made in this connection are discussed. The experience of design and operation of the systems in Rajasthan and Kalpakkam reactors has also been outlined

  1. Integrated vehicle-based safety systems : third annual report.

    Science.gov (United States)

    2009-10-01

    The Integrated Vehicle-Based Safety Systems (IVBSS) program is a five-year, two-phase cooperative : research program being conducted by an industry consortium led by the University of Michigan : Transportation Research Institute (UMTRI). The goal of ...

  2. Integrated Vehicle-Based Safety Systems Third Annual Report

    Science.gov (United States)

    2009-10-01

    The Integrated Vehicle-Based Safety Systems (IVBSS) program is a five-year, two-phase cooperative research program being conducted by an industry consortium led by the University of Michigan Transportation Research Institute (UMTRI). The goal of the ...

  3. Integrated vehicle-based safety systems : first annual report

    Science.gov (United States)

    2007-10-01

    The IVBSS (Integrated Vehicle-Based Safety Systems) program is a four-year, two phase cooperative research program being conducted by an industry team led by the University of Michigan Transportation Research Institute (UMTRI). The program began in N...

  4. Software reliability and safety in nuclear reactor protection systems

    International Nuclear Information System (INIS)

    Lawrence, J.D.

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor

  5. Analyzing Software Errors in Safety-Critical Embedded Systems

    Science.gov (United States)

    Lutz, Robyn R.

    1994-01-01

    This paper analyzes the root causes of safty-related software faults identified as potentially hazardous to the system are distributed somewhat differently over the set of possible error causes than non-safety-related software faults.

  6. Software reliability and safety in nuclear reactor protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, J.D. [Lawrence Livermore National Lab., CA (United States)

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor.

  7. Automated Flight Safety Inference Engine (AFSIE) System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop an innovative Autonomous Flight Safety Inference Engine (AFSIE) system to autonomously and reliably terminate the flight of an errant launch...

  8. Automated Flight Safety Inference Engine (AFSIE) System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop an innovative Autonomous Flight Safety Inference Engine (AFSIE) system to autonomously and reliably terminate the flight of an errant launch...

  9. The mobility and safety of walk-and-ride systems.

    Science.gov (United States)

    2015-03-01

    In this project we investigate the effect of traffic calming measures, such as crosswalks and sidewalks on the overall cost and safety of a multimodal transportation network system design. Our design problem includes auto, transit, and walking as mod...

  10. 30 CFR 7.103 - Safety system control test.

    Science.gov (United States)

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Power Packages Intended for Use in Areas of Underground Coal Mines Where Permissible Electric Equipment is Required § 7.103 Safety system...

  11. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  12. Safety review on unit testing of safety system software of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Le; Zhang Qi

    2013-01-01

    Software unit testing has an important place in the testing of safety system software of nuclear power plants, and in the wider scope of the verification and validation. It is a comprehensive, systematic process, and its documentation shall meet the related requirements. When reviewing software unit testing, attention should be paid to the coverage of software safety requirements, the coverage of software internal structure, and the independence of the work. (authors)

  13. Safety and Capacity Analysis of Automated and Manual Highway Systems

    OpenAIRE

    Carbaugh, Jason; Godbole, Datta N.; Sengupta, Raja

    1999-01-01

    This paper compares safety of automated and manual highway systems with respect to result- ing rear-end collision frequency and severity. The results show that automated driving is safer than the most alert manual drivers, at similar speeds and capacities. We also present a detailed safety-capacity tradeo study for four di erent Automated Highway System concepts that di er in their information structure and separation policy.

  14. Nuclear safety as applied to space power reactor systems

    International Nuclear Information System (INIS)

    Cummings, G.E.

    1987-01-01

    To develop a strategy for incorporating and demonstrating safety, it is necessary to enumerate the unique aspects of space power reactor systems from a safety standpoint. These features must be differentiated from terrestrial nuclear power plants so that our experience can be applied properly. Some ideas can then be developed on how safe designs can be achieved so that they are safe and perceived to be safe by the public. These ideas include operating only after achieving a stable orbit, developing an inherently safe design, ''designing'' in safety from the start and managing the system development (design) so that it is perceived safe. These and other ideas are explored further in this paper

  15. Computational methods for criticality safety analysis within the scale system

    International Nuclear Information System (INIS)

    Parks, C.V.; Petrie, L.M.; Landers, N.F.; Bucholz, J.A.

    1986-01-01

    The criticality safety analysis capabilities within the SCALE system are centered around the Monte Carlo codes KENO IV and KENO V.a, which are both included in SCALE as functional modules. The XSDRNPM-S module is also an important tool within SCALE for obtaining multiplication factors for one-dimensional system models. This paper reviews the features and modeling capabilities of these codes along with their implementation within the Criticality Safety Analysis Sequences (CSAS) of SCALE. The CSAS modules provide automated cross-section processing and user-friendly input that allow criticality safety analyses to be done in an efficient and accurate manner. 14 refs., 2 figs., 3 tabs

  16. Maintaining the Safety of Operational Health ICT Systems

    Science.gov (United States)

    Debenham, Alan

    In the context of increasing complexity and scope of computer systems used in the UK National Health Service, this paper describes the response a Foundation Trust hospital has made to the challenge. From a set of ICT activities which were founded on informal but capable principles, the expansion of the computer systems identified the need for improvements. This increasing awareness was present in the wider NHS, resulting in the publication of standards for applying safety management principles to health related software. This paper summarises the improvement measures taken across a number of areas, taking the safety case report as the focus for safety management activities.

  17. Constructing control safety systems that utilize a durable logic principle

    International Nuclear Information System (INIS)

    Oleksandr Siora; Viktor Tokatyev; Yevheniy Bakhmach

    2006-01-01

    Full text of publication follows: Our report discusses the basic principles of producing control safety systems that utilize hardware complexes designed and developed by the Research and Production Corporation (RPC) 'Radiy', Ukraine. The safety systems produced by the company are based on a principle of 'tough' logic. Our presentation describes: - functions that are performed by CSS in nuclear power stations; - principles that are realized in the equipment of hardware complexes for control safety systems; - methods for addressing sub-system components; - integration of all components into one system. We will discuss how this system performs simultaneous functions. In addition we describe the realization of fundamental safety principles. Our presentation contains data that illustrates how our unique hardware design meets the national and international standards of radiation safety in the following cases: - one time system failures; - stand by redundancy; - multiple system failures. We provide examples of how our control safety system hardware functions as a part of power generation units in nuclear power stations as follows: - Technology protection and lockout: this controls the parameters of the nuclear reactor, monitors its status for deviations and initiates the appropriate actions; - Manual remote control: the choice of manual override of the command line options that are displayed on the block control panel; - Automatic control: automatic maintenance of nuclear reactor technological parameters in normal operational and emergency modes. Our hardware system performs these functions without utilizing software. The Program Technological Complexes (PTC) for Control Safety Systems (CSS) include several standard functions such as alarm transmission, activity databases, automatic diagnostics and many others. Special attention in our presentation is given to the issues of PTC CSS reliability in all types of emergencies. (authors)

  18. A study of software safety analysis system for safety-critical software

    International Nuclear Information System (INIS)

    Chang, H. S.; Shin, H. K.; Chang, Y. W.; Jung, J. C.; Kim, J. H.; Han, H. H.; Son, H. S.

    2004-01-01

    The core factors and requirements for the safety-critical software traced and the methodology adopted in each stage of software life cycle are presented. In concept phase, Failure Modes and Effects Analysis (FMEA) for the system has been performed. The feasibility evaluation of selected safety parameter was performed and Preliminary Hazards Analysis list was prepared using HAZOP(Hazard and Operability) technique. And the check list for management control has been produced via walk-through technique. Based on the evaluation of the check list, activities to be performed in requirement phase have been determined. In the design phase, hazard analysis has been performed to check the safety capability of the system with regard to safety software algorithm using Fault Tree Analysis (FTA). In the test phase, the test items based on FMEA have been checked for fitness guided by an accident scenario. The pressurizer low pressure trip algorithm has been selected to apply FTA method to software safety analysis as a sample. By applying CASE tool, the requirements traceability of safety critical system has been enhanced during all of software life cycle phases

  19. Intrauterine nutritional programming of adult disease

    NARCIS (Netherlands)

    Piersma AH; Siemelink M; Opperhuizen A; LEO

    2001-01-01

    The intrauterine programming hypothesis states that the risk of acquiring diseases in adult life is determined in part by environmental factors during embryofetal development. Especially maternal nutrition has been related to the risk of cancer, cardiovascular disease, diabetes and infectious

  20. Intrauterine growth retardation - small events, big consequences

    Directory of Open Access Journals (Sweden)

    Ali Syed R

    2011-09-01

    Full Text Available Abstract Intrauterine growth retardation refers to a rate of growth of a fetus that is less than normal for the growth potential of a fetus (for that particular gestational age. As one of the leading causes of perinatal mortality and morbidity, intrauterine growth retardation has immense implications for the short term and long term growth of children. It is an important public health concern in the developing countries. Health statistics encompassing parameters for maternal and child health in the Indian subcontinent have shown improvement in the past few years but they are still far from perfect. Maternal health, education and empowerment bears a strong influence on perinatal outcomes including intrauterine growth retardation and should be the primary focus of any stratagem targeted at reducing the incidence of intrauterine growth retardation. A concerted liaison of various medical and social disciplines is imperative in this regard.

  1. 33 CFR 96.250 - What documents and reports must a safety management system have?

    Science.gov (United States)

    2010-07-01

    ... safety management system have? 96.250 Section 96.250 Navigation and Navigable Waters COAST GUARD... SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.250 What documents and reports must a safety management system have? The documents and reports required for a safety management...

  2. Simplified safety and containment systems for the iris reactor

    International Nuclear Information System (INIS)

    Conway, L.E.; Lombardi, C.; Ricotti, M.; Oriani, L.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) is a 100 - 300 MW modular type pressurized water reactor supported by the U.S. DOE NERI Program. IRIS features a long-life core to provide proliferation resistance and to reduce the volume of spent fuel, as well as reduce maintenance requirements. IRIS utilizes an integral reactor vessel that contains all major primary system components. This integral reactor vessel makes it possible to reduce containment size; making the IRIS more cost competitive. IRIS is being designed to enhance reactor safety, and therefore a key aspect of the IRIS program is the development of the safety and containment systems. These systems are being designed to maximize containment integrity, prevent core uncover following postulated accidents, minimize the probability and consequences of severe accidents, and provide a significant simplification over current safety system designs. The design of the IRIS containment and safety systems has been identified and preliminary analyses have been completed. The IRIS safety concept employs some unique features that minimize the consequences of postulated design basis events. This paper will provide a description of the containment design and safety systems, and will summarize the analysis results. (author)

  3. Safety analysis of tritium processing system based on PHA

    International Nuclear Information System (INIS)

    Fu Wanfa; Luo Deli; Tang Tao

    2012-01-01

    Safety analysis on primary confinement of tritium processing system for TBM was carried out with Preliminary Hazard Analysis. Firstly, the basic PHA process was given. Then the function and safe measures with multiple confinements about tritium system were described and analyzed briefly, dividing the two kinds of boundaries of tritium transferring through, that are multiple confinement systems division and fluid loops division. Analysis on tritium releasing is the key of PHA. Besides, PHA table about tritium releasing was put forward, the causes and harmful results being analyzed, and the safety measures were put forward also. On the basis of PHA, several kinds of typical accidents were supposed to be further analyzed. And 8 factors influencing the tritium safety were analyzed, laying the foundation of evaluating quantitatively the safety grade of various nuclear facilities. (authors)

  4. Evaluating software for safety systems in nuclear power plants

    International Nuclear Information System (INIS)

    Lawrence, J.D.; Persons, W.L.; Preckshot, G.G.; Gallagher, J.

    1994-01-01

    In 1991, LLNL was asked by the NRC to provide technical assistance in various aspects of computer technology that apply to computer-based reactor protection systems. This has involved the review of safety aspects of new reactor designs and the provision of technical advice on the use of computer technology in systems important to reactor safety. The latter includes determining and documenting state-of-the-art subjects that require regulatory involvement by the NRC because of their importance in the development and implementation of digital computer safety systems. These subjects include data communications, formal methods, testing, software hazards analysis, verification and validation, computer security, performance, software complexity and others. One topic software reliability and safety is the subject of this paper

  5. A new concept of safety parameter display system

    International Nuclear Information System (INIS)

    Martinez, A.S.; Oliveira, L.F.S. de; Schirru, R.; Thome Filho, Z.D.; Silva, R.A. da.

    1986-07-01

    A general description of Angra-1 Parameter Display System (SSPA), a real time and on-line computerized monitoring system for the parameters related to the power plant safety is presented. This system has the main purpose of diminish the load on the Angra-1 power plant operators at an emergency event by supplying them with the additional tools serving as the basis for a prompt identification of the accident. The SSPA is a kind of safety parameter display system whose concept was introduced after Three Mile Island accident in USA. The SSPA comprises two nuclear applications independently considered. They are included into the Parameters Monitoring Integrated System (SIMP) and the safety critical function system (SFCS). (Author) [pt

  6. Modular reliability modeling of the TJNAF personnel safety system

    International Nuclear Information System (INIS)

    Cinnamon, J.; Mahoney, K.

    1997-01-01

    A reliability model for the Thomas Jefferson National Accelerator Facility (formerly CEBAF) personnel safety system has been developed. The model, which was implemented using an Excel spreadsheet, allows simulation of all or parts of the system. Modularity os the model's implementation allows rapid open-quotes what if open-quotes case studies to simulate change in safety system parameters such as redundancy, diversity, and failure rates. Particular emphasis is given to the prediction of failure modes which would result in the failure of both of the redundant safety interlock systems. In addition to the calculation of the predicted reliability of the safety system, the model also calculates availability of the same system. Such calculations allow the user to make tradeoff studies between reliability and availability, and to target resources to improving those parts of the system which would most benefit from redesign or upgrade. The model includes calculated, manufacturer's data, and Jefferson Lab field data. This paper describes the model, methods used, and comparison of calculated to actual data for the Jefferson Lab personnel safety system. Examples are given to illustrate the model's utility and ease of use

  7. The passive safety systems of the Swr 1000

    International Nuclear Information System (INIS)

    Neumann, D.

    2001-01-01

    In recent years, a new boiling water reactor (BWR) plant called the SWR 1000 has been developed by Siemens on behalf of Germany's electric utilities. This new plant design concept incorporates the wide range of operating experience gained with German BWRs. The main objective behind developing the SWR 1000 was to design a plant with a rated electric output of approximately 1000 MW which would not only have a lower capital cost and lower power generating costs but would also provide a much higher level of nuclear safety compared to plants currently in operation. This safety-related goal has been met through, for example, the use of passive safety equipment. Passive systems make a significant contribution towards increasing the over-all level of plant safety due to the way in which they operate. They function solely accord-ing to basic laws of nature, such as gravity, and perform their designated functions with-out any need for electric power or other sources of external energy, or signals from instrumentation and control (I and C) equipment. The passive safety systems have been designed such that design basis accidents can be controlled using just these systems alone. However, the design concept of the SWR 1000 is nevertheless still based on the provision of active safety systems in addition to passive systems. (author)

  8. A concept of safety indicator system for nuclear power plants

    International Nuclear Information System (INIS)

    Lehtinen, E.

    1995-12-01

    The fundamental principle in the safety technology of nuclear power is embodied in the strategy of defence in depth. The defence lines of the strategy, completed with a PSA logic model and structure, are considered to provide an appropriate framework for identification and structuring of the operational safety performance areas for nuclear power plants. Once these areas are identified the safety indicators can be defined. Based on this approach a concept of safety indicator system was outlined. About one hundred indicator specifications have been collected, refined and related to the performance areas. The specifications enable the utilities and authorities to check the coverage of their indicators set from the operational safety point of view and select or refine indicators for testing and routine use. Finally various statistical approaches and methods for using indicators in performance evaluation are presented. (orig.) (16 refs., 2 figs., 2 tabs.)

  9. Development of a Safety Assessment Information System for the Management of Periodic Safety Assessment Activities

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tae Young [Nuclear Engineering and Technology Institute, Daejeon (Korea, Republic of)

    2007-07-01

    At present, the 10-year Periodic Safety Review(PSR) has been performing to confirm all the aspects of safety issues for all the operating plants in compliance with domestic nuclear law of article 23, subarticle 3. For each plant, in addition, Probabilistic Safety Assessment(PSA) and Severe Accident Management Guideline(SAMG) are being implemented and revised periodically to reflect the latest safety level according to principle fulfillment of severe accident policy statement. The assessment reports, as one of outcomes from these activities, are submitted into and reviewed by domestic regulatory body. During reviewing (in-office duty) and licensing (regulatory duty) process, a large number of outcomes of which most are the formal technical reports and licensing materials, are inevitably produced. Moreover, repeated review process over the plants can make them accumulated and produce a variety of documents additionally. This circumstance motivates to develop effective tool or system for the management of these reports and related technical documents for the future use in licensing process and for subsequent plant assessments. This paper presents the development status of Safety Assessment Information System(SAIS) which manages safety-related documents of PSR, PSA and SAMG for practical use for experienced engineers in charge of these areas.

  10. Risk and safety analysis of nuclear systems

    National Research Council Canada - National Science Library

    Lee, John C; McCormick, Norman J

    2011-01-01

    ...), and failure modes of systems. All of this material is general enough that it could be used in non-nuclear applications, although there is an emphasis placed on the analysis of nuclear systems...

  11. Safety analysis of reactor's cooling system

    International Nuclear Information System (INIS)

    1999-01-01

    Results of the analysis of reactor's RBMK-1500 coolant system during normal operation mode, hydrodynamic testing and in the case of earthquake are presented. Analysis was performed using RELAP5 code. Calculations showed the most vulnerable place in the reactor's coolant system. It was found that in the case of earthquake the horizontal support system of drum separator could be damaged

  12. Stakeholder Safety in Information Systems Research

    Directory of Open Access Journals (Sweden)

    R.H. Barbour

    2006-11-01

    Full Text Available Information Communication Technology (ICT researchers adapt and use tools from reference and cognate disciplines. This application of existing tools outside the context of their development has implications beyond the immediate problem context. ICT researchers have access to a wide variety of data sources including newer ones, such as the Internet, that may bring unexpected outcomes. ICT research can impact on researchers, their institutions and the researched in unexpected ways. People so affected are the stakeholders in ICT research activities. Reputations, welfare and property may be put at risk by unplanned events described in this paper. Legal aspects of ICT research are broadly identified and linked to the tort of negligence. The Social Research Association’s Code for researcher safety is described and its application extended to include the Internet as a potential data source. A common set of underlying ethical principles is identified suggesting that the ICT researcher can refine particular research protocols for specific social contexts.

  13. Safety assessment of a robotic system handling nuclear material

    International Nuclear Information System (INIS)

    Atcitty, C.B.; Robinson, D.G.

    1996-01-01

    This paper outlines the use of a Failure Modes and Effects Analysis for the safety assessment of a robotic system being developed at Sandia National Laboratories. The robotic system, The Weigh and Leak Check System, is to replace a manual process at the Department of Energy facility at Pantex by which nuclear material is inspected for weight and leakage. Failure Modes and Effects Analyses were completed for the robotics process to ensure that safety goals for the system had been meet. These analyses showed that the risks to people and the internal and external environment were acceptable

  14. Engineering systems reliability, safety, and maintenance an integrated approach

    CERN Document Server

    Dhillon, B S

    2017-01-01

    Today, engineering systems are an important element of the world economy and each year billions of dollars are spent to develop, manufacture, operate, and maintain various types of engineering systems around the globe. Many of these systems are highly sophisticated and contain millions of parts. For example, a Boeing jumbo 747 is made up of approximately 4.5 million parts including fasteners. Needless to say, reliability, safety, and maintenance of systems such as this have become more important than ever before.  Global competition and other factors are forcing manufacturers to produce highly reliable, safe, and maintainable engineering products. Therefore, there is a definite need for the reliability, safety, and maintenance professionals to work closely during design and other phases. Engineering Systems Reliability, Safety, and Maintenance: An Integrated Approach eliminates the need to consult many different and diverse sources in the hunt for the information required to design better engineering syste...

  15. Digital Signal Processing for In-Vehicle Systems and Safety

    CERN Document Server

    Boyraz, Pinar; Takeda, Kazuya; Abut, Hüseyin

    2012-01-01

    Compiled from papers of the 4th Biennial Workshop on DSP (Digital Signal Processing) for In-Vehicle Systems and Safety this edited collection features world-class experts from diverse fields focusing on integrating smart in-vehicle systems with human factors to enhance safety in automobiles. Digital Signal Processing for In-Vehicle Systems and Safety presents new approaches on how to reduce driver inattention and prevent road accidents. The material addresses DSP technologies in adaptive automobiles, in-vehicle dialogue systems, human machine interfaces, video and audio processing, and in-vehicle speech systems. The volume also features: Recent advances in Smart-Car technology – vehicles that take into account and conform to the driver Driver-vehicle interfaces that take into account the driving task and cognitive load of the driver Best practices for In-Vehicle Corpus Development and distribution Information on multi-sensor analysis and fusion techniques for robust driver monitoring and driver recognition ...

  16. Pregnancy outcome in women with an intrauterine contraceptive device.

    Science.gov (United States)

    Ganer, Hadas; Levy, Amalia; Ohel, Iris; Sheiner, Eyal

    2009-10-01

    To investigate pregnancy outcome in patients who conceived with an intrauterine contraceptive device. A retrospective study comparing the pregnancy outcome of women with retained intrauterine device (n = 98), patients after intrauterine device removal in early pregnancy (n = 194), and pregnancies without an intrauterine device (n = 141,191) was performed. A significant linear association was documented among the 3 groups and adverse outcomes such as preterm delivery (18.4% in the retained intrauterine device, 14.4 % in removed intrauterine device, and 7.3% in the no-intrauterine device group; P intrauterine device, 4.1% in removed intrauterine device and 0.7% in the no-intrauterine device group; P intrauterine device was found as an independent risk factor for both preterm delivery and chorioamnionitis in multivariable models. Women conceiving with an intrauterine device are at increased risk for adverse obstetric outcomes, whereas the risk is higher for pregnancies with retained intrauterine device compared with early intrauterine device removal.

  17. Evaluation of intelligent transport systems impact on school transport safety

    OpenAIRE

    Jankowska-Karpa Dagmara; Wacowska-Ślęzak Justyna

    2017-01-01

    The integrated system of safe transport of children to school using Intelligent Transport Systems was developed and implemented in four locations across Europe under the Safeway2School (SW2S) project, funded by the EU. The SW2S system evaluation included speed measurements and an eye-tracking experiment carried out among drivers who used the school bus route, where selected elements of the system were tested. The subject of the evaluation were the following system elements: pedestrian safety ...

  18. Artificial intelligence enhancements to safety parameter display systems

    International Nuclear Information System (INIS)

    Hajek, B.K.; Hashemi, S.; Sharma, D.; Chandrasekaran, B.; Miller, D.W.

    1986-01-01

    Two prototype knowledge based systems have been developed at The Ohio State University to be the basis of an operator aid that can be attached to an existing nuclear power plant Safety Parameter Display System. The first system uses improved sensor validation techniques to provide input to a fault diagnosis process. The second system would use the diagnostic system output to synthesize corrective procedures to aid the control room licensed operator in plant recovery

  19. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    International Nuclear Information System (INIS)

    DAVIS, S.J.

    2000-01-01

    This document identifies critical characteristics of components to be dedicated for use in Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common, radiation area, monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF) for use in safety significant systems. System modifications are to be performed in accordance with the approved design. Components for this change are commercially available and interchangeable with the existing alarm configuration This document focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications

  20. Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kelly Mahoney, Henry Robertson

    2009-10-01

    This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R&D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC. Key words: PLC, Safety, TJNAF, SIL, PSS, PPS, Software, ILC Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

  1. Analytically qualifying nuclear safety related systems and components

    International Nuclear Information System (INIS)

    Wei, A.; Porco, R.

    1993-01-01

    The seismic qualification of nuclear safety related systems and components can be achieved using finite element analysis (FEA) techniques, seismic simulation testing, or a combination of testing and analytical techniques. This paper includes discussion on qualification approaches, a detailed analytical qualification procedure, and seismic qualification practices at Ellis ampersand Watts. The seismic qualification of nuclear safety related fans using ANSYS finite element analysis code is presented as an example in the section of seismic qualification practice at Ellis ampersand Watts Company. A few tips using the FEA code for the seismic qualification are illustrated in qualifying a nuclear safety related pressure relief valve for West Valley Nuclear Services

  2. The theorization of nuclear safety regulation and legal system

    International Nuclear Information System (INIS)

    Kim, S. W.; Jang, K. H.; Oh, B. J.; Kang, S. C.; Lee, J. I.

    2001-01-01

    Nuclear safety regulation, which restricts the freedoms and rights of people, should be carried out under the principle of regulation by acts. Therefore, it should be starting point of understanding of nuclear safety regulation to understand theoretical system of administrative regulation such as legal system · sorts · effect of governmental regulatory administration. This report analysed, from a legal aspect, the concept of nuclear safety regulation and the spirit of the Framework Act on Administrative Regulation. Therefore, this report examined closely all kinds of regulatory actions sorted by its contents, discretion, added condition (Nebenbestimmungen). In addition to it, this report analysed the hierarchy of nuclear legislation in the form of act, presidential decree, enforcement regulation, notice of Minister of Science and Technology and regulatory guide of regulatory body. Finally, this report reviewed the principles for good regulation such as recommended by the NRC to grope for desirable attitude for staffs of nuclear safety regulation body

  3. An expert system approach for safety diagnosis

    International Nuclear Information System (INIS)

    Erdmann, R.C.; Sun, B.K.H.

    1988-01-01

    An expert system was developed with the intent to provide real-time information about an accident to an operator who is in the process of diagnosing and bringing that accident under control. Explicit use was made of probabilistic risk analysis techniques and plant accident response information in constructing this system. The expert system developed contains 70 logic rules and provides contextual messages during simulated accident sequences and logic sequence information on the entire sequence in graphical form for accident diagnosis. The present analysis focuses on integrated control system-related transients with Babcock and Wilcox-type reactors. While the system developed here is limited in extent and was built for a composite reactor, it demonstrates that an expert system may enhance the operator's capability in the control room

  4. Use of digital computing devices in systems important to safety

    International Nuclear Information System (INIS)

    1986-01-01

    The incorporation of digital computing devices in systems important to safety now is progressing fast in several countries, including Canada, France, Federal Republic of Germany, Japan, USA. There are now reactors with microprocessors in some trip systems. The major functions of those systems are: reactor trip initiation, display, monitoring, testing, re-calibration of detectors. The benefits of moving to a fully computerized shut-down system should be improved reliability, greater flexibility, better man-machine interface, improved testing, higher reactor output and lower overall cost. With the introduction of computer devices in systems important to safety, plant availability and safety are improved because disturbances are treated before they lead to safety action, in this way helping the operator to avoid errors. The Meeting presentations were divided into sessions devoted to the following topics: Needs for the use of digital devices (DCD) in safety important systems (SIS) (5 papers); Problems raised by the integration SIS in the NPP control (7 papers); Description and presentation of DCD of SIS (6 papers); Results of experiences in engineering, manufacture, qualification operation of DCD hardware and software (5 papers). A separate abstract was prepared for each of these papers

  5. Indus-2 machine safety interlock system - from design to commissioning

    International Nuclear Information System (INIS)

    Gothwal, Pankaj; Gupta, A.M.; Merh, B.; Fatnani, P.; Kumar, S.; Vaishnav, H.; Satheesan, T.V.

    2009-01-01

    INDUS-2 is a 2.5 GeV, 300 mA electron storage ring in operation at RRCAT, Indore. It is a one of its kind national facility with plans for 27 user beam lines from bending magnets. Any such large facility requires sufficient measures of machine safety besides occupational radiation safety during normal course of operation. In fact, machine safety is a major concern as any serious fault can cause expensive and extensive damage to machine components like magnets, vacuum chambers, vacuum valves etc. resulting in possibly long periods of machine shutdown. The machine has to clear many pre-checks to come to states of operation and certain conditions have to be maintained for operating it safely. The Machine Safety Interlock System (MSIS) must fulfil the normal requirements of a safety critical system. In the accelerator environment, such system must be easily configurable and expandable also. Therefore an intelligent computer based system has been developed and deployed. The INDUS-2 MSIS takes inputs from cooling water switches of photon absorbers and magnets, magnet coil temperatures, DCCT core temperature, vacuum sector valve status, door interlocks and search and scram system, integrated temperature status from vacuum chambers etc. The machine condition inputs to trip outputs relations are defined with equations. The paper presents the design basis, the system implementation details, performance issues and experiences. (author)

  6. 49 CFR 659.25 - Annual review of system safety program plan and system security plan.

    Science.gov (United States)

    2010-10-01

    ... annual review of its system safety program plan and system security plan. (b) In the event the rail... 49 Transportation 7 2010-10-01 2010-10-01 false Annual review of system safety program plan and system security plan. 659.25 Section 659.25 Transportation Other Regulations Relating to Transportation...

  7. Agricultural injuries in Korea and errors in systems of safety

    Directory of Open Access Journals (Sweden)

    Hyocher Kim

    2016-07-01

    It was found that most agricultural injuries were caused by a complex layer of root causes which were classified as errors in the systems of safety. This result indicates that not only training and personal protective equipment, but also regulation of safety design, mitigation devices, inspection/maintenance of workplaces, and other factors play an important role in preventing agricultural injuries. The identification of errors will help farmers to implement easily an effective prevention programme.

  8. Protective and Catching Safety Systems In Construction

    Directory of Open Access Journals (Sweden)

    Kuzhin Marat

    2017-01-01

    Full Text Available In the article is described application of protective and catching systems in construction. Classification of similar systems, their types and purpose are listed. Dangerous zones on construction site and events to for limiting their influence or protection from the factors. Protective and catching systems is one of the most effective technical equipment, applied in recent time. Protective fences and catching systems are important part in the problem solution. Protective fences protect workers from falling from height. Protective and catching systems allows avoid injuries by workers, also catch debris, fallen from constructing buildings. In regard with continuing development in technical and technological solutions, protective and catching systems require adaptation to a new requirements of construction industry and requirements of normative documents. Technical regulations in the appliance sphere of protective and catching systems requires actualization and aligning with modern normatives. Important role should be given to developing organizational and technological documentation for application of the systems. Scientific studying of technical parameters of fences and protective catching nets also has great interest.

  9. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  10. New Paradigm in Nuclear Safety from Quality Assurance to Safety Management System

    International Nuclear Information System (INIS)

    Lim, Nam-Jin; Park, Chan-Gook; Nam, Ji-Hee; Kim, Kwan-Hyun; Kwon, Hyuk-il; Lee, Young-Gun Lee

    2006-01-01

    The initial concept of Quality Control (QC) controlling the quality of products is now evolving toward the Management System (MS) achieving safety, through Quality Assurance (QA) ensuring the quality of products and Quality Management (QM) managing the quality by a systematic approach. Nuclear safety can be achieved through an integrated MS that ensures the health, environmental, security, quality and economic requirements being considered together with nuclear safety requirements. MS approach is developed through realizing that most of nuclear accidents had occurred not by the malfunction of hardware or equipment, but by the human error. The MS is a set of inter-related or interacting elements (system) that establishes policies and objectives and which enables those objectives to be achieved in an efficient and effective way

  11. Safety characteristics of potential waste transmutation systems

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.

    1993-01-01

    For nuclear waste transmutation to alter significantly the need for geologic disposal of spent fuel from US Light-water reactors (LWRs), about 1.4% of the spent fuel (by mass) must be separated and transmuted. This includes the plutonium, the minor actinides, and four fission products: iodine. technetium, cesium and strontium. Regarding the actinides, fissioning of the plutonium, neptunium, americium, and curium generates a great deal of heat, so much so that most of the plutonium should be used to produce power. However, these actinides have some undesirable neutronic characteristics, and their utilization in reactors or subcritical (proton-accelerator) targets requires either a fast neutronic spectrum or a very high thermal-neutron flux. Transmutation of the fission products is generally by neutron capture, although this is difficult in the case of cesium and strontium. In this paper, various proposed means of transmuting the actinides and fission products are discussed, with the main focus being on the safety characteristics of each approach

  12. An intelligent hybrid system for surface coal mine safety analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lilic, N.; Obradovic, I.; Cvjetic, A. [University of Belgrade, Belgrade (Serbia)

    2010-06-15

    Analysis of safety in surface coal mines represents a very complex process. Published studies on mine safety analysis are usually based on research related to accidents statistics and hazard identification with risk assessment within the mining industry. Discussion in this paper is focused on the application of AI methods in the analysis of safety in mining environment. Complexity of the subject matter requires a high level of expert knowledge and great experience. The solution was found in the creation of a hybrid system PROTECTOR, whose knowledge base represents a formalization of the expert knowledge in the mine safety field. The main goal of the system is the estimation of mining environment as one of the significant components of general safety state in a mine. This global goal is subdivided into a hierarchical structure of subgoals where each subgoal can be viewed as the estimation of a set of parameters (gas, dust, climate, noise, vibration, illumination, geotechnical hazard) which determine the general mine safety state and category of hazard in mining environment. Both the hybrid nature of the system and the possibilities it offers are illustrated through a case study using field data related to an existing Serbian surface coal mine.

  13. Spallation Neutron Source Accelerator Facility Target Safety and Non-safety Control Systems

    International Nuclear Information System (INIS)

    Battle, Ronald E.; DeVan, B.; Munro, John K. Jr.

    2006-01-01

    The Spallation Neutron Source (SNS) is a proton accelerator facility that generates neutrons for scientific researchers by spallation of neutrons from a mercury target. The SNS became operational on April 28, 2006, with first beam on target at approximately 200 W. The SNS accelerator, target, and conventional facilities controls are integrated by standardized hardware and software throughout the facility and were designed and fabricated to SNS conventions to ensure compatibility of systems with Experimental Physics Integrated Control System (EPICS). ControlLogix Programmable Logic Controllers (PLCs) interface to instruments and actuators, and EPICS performs the high-level integration of the PLCs such that all operator control can be accomplished from the Central Control room using EPICS graphical screens that pass process variables to and from the PLCs. Three active safety systems were designed to industry standards ISA S84.01 and IEEE 603 to meet the desired reliability for these safety systems. The safety systems protect facility workers and the environment from mercury vapor, mercury radiation, and proton beam radiation. The facility operators operated many of the systems prior to beam on target and developed the operating procedures. The safety and non-safety control systems were tested extensively prior to beam on target. This testing was crucial to identify wiring and software errors and failed components, the result of which was few problems during operation with beam on target. The SNS has continued beam on target since April to increase beam power, check out the scientific instruments, and continue testing the operation of facility subsystems

  14. Safety

    International Nuclear Information System (INIS)

    1998-01-01

    A brief account of activities carried out by the Nuclear power plants Jaslovske Bohunice in 1997 is presented. These activities are reported under the headings: (1) Nuclear safety; (2) Industrial and health safety; (3) Radiation safety; and Fire protection

  15. An intelligent safety system concept for future CANDU reactors

    International Nuclear Information System (INIS)

    Hinds, H.W.

    1980-01-01

    A review of the current Regional Over-power Trip (ROPT) system employed on the Bruce NGS-A reactors confirmed the belief that future reactors should have an improved ROPT system. We are developing such an 'intelligent' safety system. It uses more of the available information on reactor status and employs modern computer technology. Fast triplicated safety computers compute maps of fuel channel power, based on readings from prompt-responding flux detectors. The coefficients for this calculation are downloaded periodically from a fourth supervisor computer. These coefficients are based on a detailed 3-D flux shape derived from physics data and other plant information. A demonstration of one of three safety channels of such a system is planned. (auth)

  16. Nuclear power safety reporting system feasibility analysis and concept description

    International Nuclear Information System (INIS)

    Finlayson, F.C.; Ims, J.R.; Hussman, T.A.

    1984-01-01

    The Aerospace Corporation is assisting the US Nuclear Regulatory Commission (NRC) in the evaluation of the potential attributes of a voluntary, nonpunitive data gathering system for identifying and quantifying the factors that contribute to the occurrence of significant safety problems involving humans in nuclear power plants. The objectives of the Aerospace Administration (FAA)/National Aeronautics and Space Administration (NASA) Aviation Safety Reporting System (ASRS) in order to determine whether it would be feasible to apply part (or all) of the ASRS concepts for collecting data on human factor related incidents to the nuclear industry; and (2) to identify and define the basic elements and requirements of a Nuclear Power Safety Reporting System (NPSRS), assuming the feasibility of implementing such a system was established

  17. Operation safety of control systems. Principles and methods

    International Nuclear Information System (INIS)

    Aubry, J.F.; Chatelet, E.

    2008-01-01

    This article presents the main operation safety methods that can be implemented to design safe control systems taking into account the behaviour of the different components with each other (binary 'operation/failure' behaviours, non-consistent behaviours and 'hidden' failures, dynamical behaviours and temporal aspects etc). To take into account these different behaviours, advanced qualitative and quantitative methods have to be used which are described in this article: 1 - qualitative methods of analysis: functional analysis, preliminary risk analysis, failure mode and failure effects analyses; 2 - quantitative study of systems operation safety: binary representation models, state space-based methods, event space-based methods; 3 - application to the design of control systems: safe specifications of a control system, qualitative analysis of operation safety, quantitative analysis, example of application; 4 - conclusion. (J.S.)

  18. Routine testing on protective and safety systems and components

    International Nuclear Information System (INIS)

    Rysy, W.

    1977-01-01

    1) In-process inspection, tests during commissioning. 2) Tests during reactor operation. 2.1) Reactor protection system, for example: continuous auto-testing by a dynamic system, check of the output signals; 2.2) safety features: selected examples: functional tests on the ECCS, trial operation of the emergency diesels. 3) Tests during refuelling phase. 3.1) Containment: Leakage rate tests, leak testing; 3.2) coolant system: selected examples: inservice inspections of the pressure vessel, eddy current testing of the steam generator, functional tests of safety valves. (orig./HP) [de

  19. Driver monitoring system for automotive safety

    Science.gov (United States)

    Lörincz, A. E.; Risteiu, M. N.; Ionica, A.; Leba, M.

    2018-01-01

    The lifestyle of a person is a very active one from all points of view. He travels great distance every day, with car or on foot. Tiredness and stress is found in every person. These can cause major problems when driving up and driving in small or big distances by car. A system developed to prevent the dangers we are prone to in these situations is very useful. System that can be used and implemented both in the production of current cars and the use of those not equipped with this system.

  20. Monitoring and crisis system of radiation safety

    International Nuclear Information System (INIS)

    Bartok, J.; Borovansky, P.; Macica, J.; Petrovicova, M.

    2005-01-01

    In this paper we have briefly described our practical experiences with the most complex Radiation Monitoring System we have designed. This system consists of number of stations; those data are collected in the main crisis center of the whole system. The main center integrates RMS Central Database, the IMS Model Suite workstation and the Graphics workstation. The radiations probes of the RP series are the base for stationary , portable sets and for sets measuring underwater radiation. The radiation and meteorological data, which are necessary for reasonable interpretation of radiation data, are archived in RMS Central database. The Lagrangian trajectory model from the IMS Model Suite serves for radiation dispersion modeling. (authors)

  1. Risk and safety analysis of nuclear systems

    CERN Document Server

    Lee, John C

    2011-01-01

    The book has been developed in conjunction with NERS 462, a course offered every year to seniors and graduate students in the University of Michigan NERS program. The first half of the book covers the principles of risk analysis, the techniques used to develop and update a reliability data base, the reliability of multi-component systems, Markov methods used to analyze the unavailability of systems with repairs, fault trees and event trees used in probabilistic risk assessments (PRAs), and failure modes of systems. All of this material is general enough that it could be used in non-nuclear a

  2. Verifying therapy safety interlock system with spin

    CSIR Research Space (South Africa)

    Seotsanyana, M

    2009-11-01

    Full Text Available System component represents TCS systems and electronic units. It connects to the TSB and TCS lines by sending a message register to the tlabsMediator component and unconnect from these lines through an unregister message. It also changes lines to either true... or false and emits two different messages (update and notify) to the tlabMediator component. The sysUtility component takes care of administrative work for the tlabSystem components, including receiving the display messages from other components. The tlabMediator...

  3. Proceedings of the Digital Systems Reliability and Nuclear Safety Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, D. R.; Cuthill, B. B.; Ippolito, L. M. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Beltracchi, L. [Nuclear Regulatory Commission, Washington, DC (United States) ed.

    1994-03-01

    The United States Nuclear Regulatory Commission (NRC), in cooperation with the National Institute of Standards and Technology conducted the.Digital Systems Reliability and Nuclear Safety Workshop on September 13--14, 1993, in Rockville, Maryland. The workshop provided a forum for the exchange of information among experts within the nuclear industry, experts from other industries, regulators and academia. The information presented at this workshop provided in-depth exposure of the NRC staff and the nuclear industry to digital systems design safety issues and also provided feedback to the NRC from outside experts regarding identified safety issues, proposed regulatory positions, and intended research associated with the use of digital systems in nuclear power plants. Technical presentations provided insights on areas where current software engineering practices may be inadequate for safety-critical systems, on potential solutions for development issues, and on methods for reducing risk in safety-critical systems. This report contains an analysis of results of the workshop, the papers presented panel presentations, and summaries of, discussions at this workshop. The individual papers have been cataloged separately.

  4. Antilock Braking Systems: Traffic Safety Tips

    Science.gov (United States)

    1996-01-01

    This fact sheet, the NHTSA Facts: Summer 1996, defines antilock braking systems, and discusses their benefits, how they work, and their major components. It also details how one would get used to antilock brakes, discussing how they feel and operate ...

  5. Risk and safety analysis of nuclear systems

    National Research Council Canada - National Science Library

    Lee, John C; McCormick, Norman J

    2011-01-01

    .... The first half of the book covers the principles of risk analysis, the techniques used to develop and update a reliability data base, the reliability of multi-component systems, Markov methods used...

  6. Use of expert systems in nuclear safety

    International Nuclear Information System (INIS)

    1990-02-01

    One dominant aspect of improvement in safe nuclear power plant operation is the very high speed in the development and introduction of computer technologies. This development commenced recently when advanced control technology was incorporated into the nuclear industry. This led to an increasing implementation of information displays, annunciator windows and other devices inside the control room, eventually overburdening the control room operator with detailed information. Expert systems are a further step in this direction being designed to apply large knowledge bases to solve practical problems. These ''intelligent'' systems have to incorporate enough knowledge to reach expert levels of importance and represent a very advanced man-machine interface. The aims of the Technical Committee were addressed by the three Working Groups and summarized in Sections 2, 3 and 4 of this report. Section 2 summarizes the results and discussions on the current capabilities of expert systems and identifies features for the future development and use of Expert Systems in Nuclear Power Plants. Section 3 provides an overview of the discussions and investigations into the current status of Expert Systems in NPPs. This section develops a method for assessing the overall benefit of different applications and recommends a broad strategy for priority developments of Expert Systems in NPPs. Section 4 assesses the overall use of PSA type studies in Expert Systems in NPPs and identifies specific features to be adopted in the design of these systems in future applications. The conclusions of the three Working Groups are presented in Section 5. The 15 papers presented at the meeting formed the Annex of this document. A separate abstract was prepared for each of these papers. Refs, figs, tabs and pictures

  7. Automated Systems for Road Safety control in a Developing World ...

    African Journals Online (AJOL)

    An Automated system was finally designed and developed for road safety control. This Automated system is believed to have the capacity to minimize or eliminate the problems identified in this study on traffic control in a developing world. Key words: drivers, traffic situation information, accident causation, FRSC ...

  8. Expert evaluation in NPP safety important systems licensing process

    International Nuclear Information System (INIS)

    Mikhail, A Yastrebenetsky; Vasilchenko, V.N.

    2001-01-01

    Expert evaluation of nuclear power plant safety important systems modernization is an integral part of these systems licensing process. The paper contains some aspects of this evaluation which are based on Ukrainian experience of VVER-1000 and VVER-440 modernization. (authors)

  9. Continuous restraint control systems: safety improvement for various occupants

    NARCIS (Netherlands)

    Laan, E. van der; Jager, B. de; Veldpaus, F.; Steinbuch, M.; Nunen, E. van; Willemsen, D.

    2009-01-01

    Occupant safety can be significantly improved by continuous restraint control systems. These restraint systems adjust their configuration during the impact according to the actual operating conditions, such as occupant size, weight, occupant position, belt usage and crash severity. In this study,

  10. System safety program plan for the Isotope Brayton Ground Demonstration System (phase I)

    International Nuclear Information System (INIS)

    1976-01-01

    The safety engineering effort to be undertaken in achieving an acceptable level of safety in the Brayton Isotope Power System (BIPS) development program is discussed. The safety organizational relationships, the methods to be used, the tasks to be completed, and the documentation to be published are described. The plan will be updated periodically as the need arises

  11. A Nuclear Safety System based on Industrial Computer

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Oh, Do Young; Lee, Nam Hoon; Kim, Chang Ho; Kim, Jae Hack

    2011-01-01

    The Plant Protection System(PPS), a nuclear safety Instrumentation and Control (I and C) system for Nuclear Power Plants(NPPs), generates reactor trip on abnormal reactor condition. The Core Protection Calculator System (CPCS) is a safety system that generates and transmits the channel trip signal to the PPS on an abnormal condition. Currently, these systems are designed on the Programmable Logic Controller(PLC) based system and it is necessary to consider a new system platform to adapt simpler system configuration and improved software development process. The CPCS was the first implementation using a micro computer in a nuclear power plant safety protection system in 1980 which have been deployed in Ulchin units 3,4,5,6 and Younggwang units 3,4,5,6. The CPCS software was developed in the Concurrent Micro5 minicomputer using assembly language and embedded into the Concurrent 3205 computer. Following the micro computer based CPCS, PLC based Common-Q platform has been used for the ShinKori/ShinWolsong units 1,2 PPS and CPCS, and the POSAFE-Q PLC platform is used for the ShinUlchin units 1,2 PPS and CPCS. In developing the next generation safety system platform, several factors (e.g., hardware/software reliability, flexibility, licensibility and industrial support) can be considered. This paper suggests an Industrial Computer(IC) based protection system that can be developed with improved flexibility without losing system reliability. The IC based system has the advantage of a simple system configuration with optimized processor boards because of improved processor performance and unlimited interoperability between the target system and development system that use commercial CASE tools. This paper presents the background to selecting the IC based system with a case study design of the CPCS. Eventually, this kind of platform can be used for nuclear power plant safety systems like the PPS, CPCS, Qualified Indication and Alarm . Pami(QIAS-P), and Engineering Safety

  12. Nuclear safety considerations with emphasis on instrumentation and control systems

    International Nuclear Information System (INIS)

    Beare, J.W.

    1978-01-01

    The conceptual model of a nuclear power plant in Canada is that it consists basically of two kinds of systems. The first kind is the process systems, that is, those structures and components associated with the production of nuclear energy and its conversion to other forms of energy. The second kind is the special safety systems, whose purpose it is to protect the public in the event of a serious failure in the process systems which might otherwise lead to unacceptable radiological consequences. Quantitative limits are set on the unavailability of the special safety systems. These limits are low enough to be consistent with low overall risk and yet can be demonstrated by test during operation of the plant. Low unavailability is an important but not the only condition required for low unrealiability for the special safety systems. The special safety systems minimize the chance of a cross-linked failure particularly under the conditions experienced as a result of the more severe types of postulated serious process failures. Nuclear power plants must also withstand, without a major hazard to the public, certain rare events associated with natural phenomena or man-made activities off-site and also certain in-plant events such as fire or break-up of a turbine-generator which might have a cross-linking effect on process and safety systems. In the latest designs, Canadian nuclear power plants have emergency systems to deal with such events. The emergency systems have an enhanced degree of physical and functional separation from other plant systems. (author)

  13. Status of the EU test blanket systems safety studies

    International Nuclear Information System (INIS)

    Panayotov, Dobromir; Poitevin, Yves; Ricapito, Italo; Zmitko, Milan

    2015-01-01

    Highlights: • TBS safety demonstration files. • Safety functions and related design features – detailed TBS components classifications. • Nuclear analyses, radiation shielding and protection. • TBS radiological waste management strategy and categorization. • Selection and definition of reference accidents scenarios and accidents analyses. - Abstract: The European joint undertaking for ITER and the development of fusion energy (‘Fusion for Energy’ – F4E) provides the European contributions to the ITER international fusion energy research project. Among others it includes also the development, design, technological demonstration and implementation of the European test blanket systems (TBS) in ITER. Currently two EU TBS designs are in the phase of conceptual design – helium-cooled lithium-lead (HCLL) and helium-cooled pebble-bed (HCPB). Safety demonstration is an important part of the work devoted to the achievement of the next key project milestone the conceptual design review. The paper reveals the details of the work on EU TBS safety performed in the last couple of years: update of the TBS safety demonstration files; safety functions and related design features; detailed TBS components classifications; nuclear analyses, radiation shielding and protection; TBS radiological waste management strategy and categorization; selection and definition of reference accidents scenarios, and accidents analyses. Finally the authors share the information on on-going and planned future EU TBS safety activities.

  14. Benefits of a systematic approach to maintenance for safety and safety related systems

    International Nuclear Information System (INIS)

    Dam, R.F.; Ayazzudin, S.; Nickerson, J.H.

    2003-01-01

    For safety and safety-related systems, nuclear plants have to balance the requirements of demonstrating the reliability of each system, while maintaining the system and plant availability. With the goal of demonstrating statistical reliability, these systems have extensive testing programs, which often results in system unavailability and this can impact the plant capacity. The inputs to the process are often safety and regulatory related, resulting in programs that provide a high level of scrutiny. In such cases, the value of the application of a Systematic Assessment of Maintenance (SAM) process, such as Reliability Centered Maintenance (RCM), is questioned. The special case of Standby-Safety systems was discussed in a previous paper, where it was demonstrated how SAM techniques provide useful insight into current system performance, the impact of testing on component and system reliability, and how PSA considerations can be integrated into a comprehensive Maintenance, Surveillance, and Inspection (MSI) strategy. Although the system reliability requirements are an important part of the strategy evaluation, SAM techniques provide a systematic assessment within a broader context. Testing is only one part of an overall strategy focused on ensuring that component function is maintained through a combination of monitoring technologies (including testing), predictive techniques, and intrusive maintenance strategies. Each strategy is targeted to known component degradation mechanisms. This thinking can be extended to safety and safety related systems in general. Over the past 6 years, AECL has been working with CANDU utilities in the development and implementation of a comprehensive and integrated Plant Life Management (PLiM) program. As part of developing a comprehensive plant asset management approach, SAM techniques are used to develop a technical basis that not only works towards ensuring reliable operation of plant systems, but also facilitates the optimization and

  15. Design of integrated passive safety system (IPSS) for ultimate passive safety of nuclear power plants

    International Nuclear Information System (INIS)

    Chang, Soon Heung; Kim, Sang Ho; Choi, Jae Young

    2013-01-01

    Highlights: • We newly propose the design concept of integrated passive safety system (IPSS). • It has five safety functions for decay heat removal and severe accident mitigation. • Simulations for IPSS show that core melt does not occur in accidents with SBO. • IPSS can achieve the passive in-vessel retention and ex-vessel cooling strategy. • The applicability of IPSS is high due to the installation outside the containment. -- Abstract: The design concept of integrated passive safety system (IPSS) which can perform various passive safety functions is proposed in this paper. It has the various functions of passive decay heat removal system, passive safety injection system, passive containment cooling system, passive in-vessel retention and cavity flooding system, and filtered venting system with containment pressure control. The objectives of this paper are to propose the conceptual design of an IPSS and to estimate the design characters of the IPSS with accident simulations using MARS code. Some functions of the IPSS are newly proposed and the other functions are reviewed with the integration of the functions. Consequently, all of the functions are modified and integrated for simplicity of the design in preparation for beyond design based accidents (BDBAs) focused on a station black out (SBO). The simulation results with the IPSS show that the decay heat can be sufficiently removed in accidents that occur with a SBO. Also, the molten core can be retained in a vessel via the passive in-vessel retention strategy of the IPSS. The actual application potential of the IPSS is high, as numerous strong design characters are evaluated. The installation of the IPSS into the original design of a nuclear power plant requires minimal design change using the current penetrations of the containment. The functions are integrated in one or two large tanks outside the containment. Furthermore, the operation time of the IPSS can be increased by refilling coolant from the

  16. CONACS, the DOE safety analysis system

    International Nuclear Information System (INIS)

    Martin, F.J.; Armstrong, G.R.; Niccoli, L.G.

    1985-01-01

    The CONtainment Analysis Code System (CONACS) is a large, comprehensive scientific simulation system for predicting conditions in an LMR facility following the occurrence of a postulated accident. It has now been developed to a stage of completion that can be referred to as a limited operational version. This version forms a permanent portion of the ultimate system. Because CONACS was developed with change in mind it is now possible to draw on this strength to respond to changing requirements arising from advanced design concepts. The generalized design applications in the nuclear and non-nuclear fields and the quality assurance applied to the project make those adaptations reliable. In this paper the results of prototype tests and the implications of limited version tests are presented along with a brief description of CONACS and its relationship to LMR design optimization and cost reduction

  17. Safety assessment of emergency power systems for nuclear power plants

    International Nuclear Information System (INIS)

    1992-01-01

    This publication is intended to assist the safety assessor within a regulatory body, or one working as a consultant, in assessing the safety of a given design of the emergency power systems (EPS) for a nuclear power plant. The present publication refers closely to the NUSS Safety Guide 50-SG-D7 (Rev. 1), Emergency Power Systems at Nuclear Power Plants. It covers therefore exactly the same technical subject as that Safety Guide. In view of its objective, however, it attempts to help in the evaluation of possible technical solutions which are intended to fulfill the safety requirements. Section 2 clarifies the scope further by giving an outline of the assessment steps in the licensing process. After a general outline of the assessment process in relation to the licensing of a nuclear power plant, the publication is divided into two parts. First, all safety issues are presented in the form of questions that have to be answered in order for the assessor to be confident of a safe design. The second part presents the same topics in tabulated form, listing the required documentation which the assessor has to consult and those international and national technical standards pertinent to the topics. An extensive reference list provides information on standards. 1 tab

  18. Software qualification for digital safety system in KNICS project

    International Nuclear Information System (INIS)

    Kwon, Kee-Choon; Lee, Dong-Young; Choi, Jong-Gyun

    2012-01-01

    In order to achieve technical self-reliance in the area of nuclear instrumentation and control, the Korea Nuclear Instrumentation and Control System (KNICS) project had been running for seven years from 2001. The safety-grade Programmable Logic Controller (PLC) and the digital safety system were developed by KNICS project. All the software of the PLC and digital safety system were developed and verified following the software development life cycle Verification and Validation (V and V) procedure. The main activities of the V and V process are preparation of software planning documentations, verification of the Software Requirement Specification (SRS), Software Design Specification (SDS) and codes, and a testing of the software components, the integrated software, and the integrated system. In addition, a software safety analysis and a software configuration management are included in the activities. For the software safety analysis at the SRS and SDS phases, the software Hazard Operability (HAZOP) was performed and then the software fault tree analysis was applied. The software fault tree analysis was applied to a part of software module with some critical defects identified by the software HAZOP in SDS phase. The software configuration management was performed using the in-house tool developed in the KNICS project. (author)

  19. Pediatric safety incidents from an intensive care reporting system.

    Science.gov (United States)

    Skapik, Julia Lynn; Pronovost, Peter J; Miller, Marlene R; Thompson, David A; Wu, Albert W

    2009-06-01

    Adverse events impose a great burden on patients and the health care system, but not enough is known about how to address incidents involving pediatric patients. This study examined the demographic factors, types of events, contributing system factors, and harm associated with incidents that occur in pediatric intensive care units. Cross-sectional analysis of 2 years of data on all pediatric safety incidents and near misses reported to the voluntary provider-recorded Intensive Care Unit Safety Reporting System in regards to harm and contributing factors. In 464 incidents reported from 23 intensive care units to the Intensive Care Unit Safety Reporting System, patients were physically injured in one third of incidents and harmed in some way in two thirds of incidents. Medication errors were the most common incident type, but were associated with less harm than other event types. Line, tube, and airway events comprised one third of incidents and were associated with more harm than other types. Patient contributing factors were a strong predictor of harm; training and education factors were also commonly cited. In multivariate analysis, patient factors were the strongest predictor of harm adjusting for age, sex, and race. Pediatric patients are commonly harmed in intensive care units. There are several potential ways to improve safety including protocols for high-risk procedures involving lines and tubes, improved monitoring, and staffing, training and communication initiatives. Providers may be able to identify patients at increased risk for harm and intervene to protect patient safety.

  20. Lithium-thionyl chloride cell system safety hazard analysis

    Science.gov (United States)

    Dampier, F. W.

    1985-03-01

    This system safety analysis for the lithium thionyl chloride cell is a critical review of the technical literature pertaining to cell safety and draws conclusions and makes recommendations based on this data. The thermodynamics and kinetics of the electrochemical reactions occurring during discharge are discussed with particular attention given to unstable SOCl2 reduction intermediates. Potentially hazardous reactions between the various cell components and discharge products or impurities that could occur during electrical or thermal abuse are described and the most hazardous conditions and reactions identified. Design factors influencing the safety of Li/SOCl2 cells, shipping and disposal methods and the toxicity of Li/SOCl2 battery components are additional safety issues that are also addressed.

  1. Access Safety Systems – New Concepts from the LHC Experience

    CERN Document Server

    Ladzinski, T; di Luca, S; Hakulinen, T; Hammouti, L; Riesco, T; Nunes, R; Ninin, P; Juget, J-F; Havart, F; Valentini, F; Sanchez-Corral Mena, E

    2011-01-01

    The LHC Access Safety System has introduced a number of new concepts into the domain of personnel protection at CERN. These can be grouped into several categories: organisational, architectural and concerning the end-user experience. By anchoring the project on the solid foundations of the IEC 61508/61511 methodology, the CERN team and its contractors managed to design, develop, test and commission on time a SIL3 safety system. The system uses a successful combination of the latest Siemens redundant safety programmable logic controllers with a traditional relay logic hardwired loop. The external envelope barriers used in the LHC include personnel and material access devices, which are interlocked door-booths introducing increased automation of individual access control, thus removing the strain from the operators. These devices ensure the inviolability of the controlled zones by users not holding the required credentials. To this end they are equipped with personnel presence detectors and th...

  2. System Safety Hazards Assessment in Conceptual Program Trade Studies

    Science.gov (United States)

    Eben, Dennis M.; Saemisch, Michael K.

    2003-01-01

    Providing a program in the concept development phase with a method of determining system safety benefits of potential concepts has always been a challenge. Lockheed Martin Space and Strategic Missiles has developed a methodology for developing a relative system safety ranking using the potential hazards of each concept. The resulting output supports program decisions with system safety as an evaluation criterion with supporting data for evaluation. This approach begins with a generic hazards list that has been tailored for the program being studied and augmented with an initial hazard analysis. Each proposed concept is assessed against the list of program hazards and ranked in three derived areas. The hazards can be weighted to show those that are of more concern to the program. Sensitivities can be also be determined to test the robustness of the conclusions

  3. Safety design integrated in the Building Delivery System

    DEFF Research Database (Denmark)

    Jørgensen, Kirsten

    2012-01-01

    phases of the building delivery system by using the principle of the lean construction modelling. The method for the research was to go through the lean construction building delivery system step by step and create a normative description of what to do, when to do and how to do to fully integration...... and the consultants. The result is a concept and guideline including control schemes for how to integrate safety design in the lean construction building delivery system including what to do and when. The concept has been tested in an educational context and found useful by the designers. The practical value...... of safety in each process. The group of participants who created the description had a high experience in a combination of research, safety and health in general and especial in construction and knowledge of the lean construction processes both from the clients perspective as well as from the designers...

  4. Cyber Security Risk Assessment for the KNICS Safety Systems

    International Nuclear Information System (INIS)

    Lee, C. K.; Park, G. Y.; Lee, Y. J.; Choi, J. G.; Kim, D. H.; Lee, D. Y.; Kwon, K. C.

    2008-01-01

    In the Korea Nuclear I and C Systems Development (KNICS) project the platforms for plant protection systems are developed, which function as a reactor shutdown, actuation of engineered safety features and a control of the related equipment. Those are fully digitalized through the use of safety-grade programmable logic controllers (PLCs) and communication networks. In 2006 the Regulatory Guide 1.152 (Rev. 02) was published by the U.S. NRC and it describes the application of a cyber security to the safety systems in the Nuclear Power Plant (NPP). Therefore it is required that the new requirements are incorporated into the developed platforms to apply to NPP, and a cyber security risk assessment is performed. The results of the assessment were input for establishing the cyber security policies and planning the work breakdown to incorporate them

  5. Safety of Hydrogen Systems Installed in Outdoor Enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-11-01

    The Hydrogen Safety Panel brings a broad cross-section of expertise from the industrial, government, and academic sectors to help advise the U.S. Department of Energy’s (DOE) Fuel Cell Technologies Office through its work in hydrogen safety, codes, and standards. The Panel’s initiatives in reviewing safety plans, conducting safety evaluations, identifying safety-related technical data gaps, and supporting safety knowledge tools and databases cover the gamut from research and development to demonstration and deployment. The Panel’s recent work has focused on the safe deployment of hydrogen and fuel cell systems in support of DOE efforts to accelerate fuel cell commercialization in early market applications: vehicle refueling, material handling equipment, backup power for warehouses and telecommunication sites, and portable power devices. This paper resulted from observations and considerations stemming from the Panel’s work on early market applications. This paper focuses on hydrogen system components that are installed in outdoor enclosures. These enclosures might alternatively be called “cabinets,” but for simplicity, they are all referred to as “enclosures” in this paper. These enclosures can provide a space where a flammable mixture of hydrogen and air might accumulate, creating the potential for a fire or explosion should an ignition occur. If the enclosure is large enough for a person to enter, and ventilation is inadequate, the hydrogen concentration could be high enough to asphyxiate a person who entered the space. Manufacturers, users, and government authorities rely on requirements described in codes to guide safe design and installation of such systems. Except for small enclosures used for hydrogen gas cylinders (gas cabinets), fuel cell power systems, and the enclosures that most people would describe as buildings, there are no hydrogen safety requirements for these enclosures, leaving gaps that must be addressed. This paper proposes that

  6. Safety Verification for Probabilistic Hybrid Systems

    Czech Academy of Sciences Publication Activity Database

    Zhang, J.; She, Z.; Ratschan, Stefan; Hermanns, H.; Hahn, E.M.

    2012-01-01

    Roč. 18, č. 6 (2012), s. 572-587 ISSN 0947-3580 R&D Projects: GA MŠk OC10048; GA ČR GC201/08/J020 Institutional research plan: CEZ:AV0Z10300504 Keywords : model checking * hybrid systems * formal verification Subject RIV: IN - Informatics, Computer Science Impact factor: 1.250, year: 2012

  7. Survey of systems safety analysis methods and their application to nuclear waste management systems

    Energy Technology Data Exchange (ETDEWEB)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study.

  8. Survey of systems safety analysis methods and their application to nuclear waste management systems

    International Nuclear Information System (INIS)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study

  9. Survey of systems safety analysis methods and their application to nuclear waste management systems

    Science.gov (United States)

    Pelto, P. J.; Winegardner, W. K.; Gallucci, R. H. V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause consequence diagrams, GO methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study.

  10. Safety Justification of Software Systems. Software Based Safety Systems. Regulatory Inspection Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Dahll, Gustav (OECD Halden Project, Halden (NO)); Liwaang, Bo (Swedish Nuclear Power Inspectorate, Stockholm (Sweden)); Wainwright, Norman (Wainwright Safety Advice (GB))

    2006-07-01

    The introduction of new software based technology in the safety systems in nuclear power plants also makes it necessary to develop new strategies for regulatory review and assessment of these new systems that is more focused on reviewing the processes at the different phases in design phases during the system life cycle. It is a general requirement that the licensee shall perform different kinds of reviews. From a regulatory point of view it is more cost effective to assess that the design activities at the suppliers and the review activities within the development project are performed with good quality. But the change from more technical reviews over to the development process oriented approach also cause problems. When reviewing development and quality aspects there are no 'hard facts' that can be judged against some specified criteria, the issues are more 'soft' and are more to build up structure of arguments and evidences that the requirements are met. The regulatory review strategy must therefore change to follow the development process over the whole life cycle from concept phase until installation and operation. Even if we know what factors that is of interest we need some guidance on how to interpret and judge the information.For that purpose SKl started research activities in this area at the end of the 1990s. In the first phase, in co-operation with Gustav Dahll at the Halden project, a life cycle model was selected. For the different phases a qualitative influence net was constructed of the type that is used in Bayesian Believe Network together with a discussion on different issues involved. In the second phase of the research work, in co-operation with Norman Wainwright, a former NII inspector, information from a selection of the most important sources as guidelines, IAEA and EC reports etc, was mapped into the influence net structure (the total list on used sources are in the report). The result is presented in the form of

  11. Safety Justification of Software Systems. Software Based Safety Systems. Regulatory Inspection Handbook

    International Nuclear Information System (INIS)

    Dahll, Gustav; Liwang, Bo; Wainwright, Norman

    2006-01-01

    The introduction of new software based technology in the safety systems in nuclear power plants also makes it necessary to develop new strategies for regulatory review and assessment of these new systems that is more focused on reviewing the processes at the different phases in design phases during the system life cycle. It is a general requirement that the licensee shall perform different kinds of reviews. From a regulatory point of view it is more cost effective to assess that the design activities at the suppliers and the review activities within the development project are performed with good quality. But the change from more technical reviews over to the development process oriented approach also cause problems. When reviewing development and quality aspects there are no 'hard facts' that can be judged against some specified criteria, the issues are more 'soft' and are more to build up structure of arguments and evidences that the requirements are met. The regulatory review strategy must therefore change to follow the development process over the whole life cycle from concept phase until installation and operation. Even if we know what factors that is of interest we need some guidance on how to interpret and judge the information.For that purpose SKl started research activities in this area at the end of the 1990s. In the first phase, in co-operation with Gustav Dahll at the Halden project, a life cycle model was selected. For the different phases a qualitative influence net was constructed of the type that is used in Bayesian Believe Network together with a discussion on different issues involved. In the second phase of the research work, in co-operation with Norman Wainwright, a former NII inspector, information from a selection of the most important sources as guidelines, IAEA and EC reports etc, was mapped into the influence net structure (the total list on used sources are in the report). The result is presented in the form of questions (Q) and a

  12. Argument for a Joint Safety Reporting System

    Science.gov (United States)

    2015-02-13

    awaiting a rejoin with the remaining flight members when distraction leads to a mid-air collision; both pilots safely eject but the jets crash into the...utilizes a “ Turbo -Tax” type interface to guide users through the report submission process only. The interface is strictly for reporting and does...application for Class A-E mishap reporting across all disciplines, with “ Turbo -Tax” type entry. The system provides the means to document all required

  13. Triangle of prevention: a union's experience promoting a systems-of-safety health and safety program.

    Science.gov (United States)

    McQuiston, Thomas H; Cable, Steve; Cook, Linda; Drewery, Karen; Erwin, Glenn; Frederick, James; Lessin, Nancy; Ouellette, Dan; Scardella, John; Spaeth, Colin; Wright, Mike

    2012-01-01

    After years of watching company health and safety programs fail to prevent major incidents, injuries, illness, and death in industrial workplaces, union health and safety staff and rank and file activists took up the challenge of creating a union-run alternative program. Named the Triangle of Prevention (TOP), the program successfully engages both local unions and management in incident and near-miss reporting and investigation, root cause analysis, recommending and tracking solutions, and learning and sharing lessons. In all phases, TOP uses a hierarchical, systems-of-safety-based approach to hazard identification, reporting, prevention and control while aiming to engage the union, its members, and all other employees of a worksite. This article explains the foundations and workings of this program, the role of an expansive worker-to-worker training regimen, and the ways in which the program has transformed workplaces.

  14. Nickel-iron battery system safety

    Science.gov (United States)

    Saltat, R. C.

    1984-06-01

    The generated flow rates of gaseous hydrogen and gaseous oxygen from an electrical vehicle nickel-iron battery system were determined and used to evaluate the flame quenching capabilities of several candidate devices to prevent flame propagation within batteries having central watering/venting systems. The battery generated hydrogen and oxygen gases were measured for a complete charge and discharge cycle. The data correlates well with accepted theory during strong overcharge conditions indicating that the measurements are valid for other portions of the cycle. Tests confirm that the gas mixture in the cells is always flammable regardless of the battery status. The literature indicated that a conventional flame arrestor would not be effective over the broad spectrum of gassing conditions presented by a nickel-iron battery. Four different types of protective devices were evaluated. A foam-metal arrestor design was successful in quenching gaseous hydrogen and gaseous oxygen flames, however; the application of this flame arrestor to individual cell or module protection in a battery is problematic. A possible rearrangement of the watering/venting system to accept the partial protection of simple one-way valves is presented which, in combination with the successful foam-metal arrestor as main vent protection, could result in a significant improvement in battery protection.

  15. Risk-based rules for crane safety systems

    International Nuclear Information System (INIS)

    Ruud, Stian; Mikkelsen, Age

    2008-01-01

    The International Maritime Organisation (IMO) has recommended a method called formal safety assessment (FSA) for future development of rules and regulations. The FSA method has been applied in a pilot research project for development of risk-based rules and functional requirements for systems and components for offshore crane systems. This paper reports some developments in the project. A method for estimating target reliability for the risk-control options (safety functions) by means of the cost/benefit decision criterion has been developed in the project and is presented in this paper. Finally, a structure for risk-based rules is proposed and presented

  16. The Advanced Light Source (ALS) Radiation Safety System

    International Nuclear Information System (INIS)

    Ritchie, A.L.; Oldfather, D.E.; Lindner, A.F.

    1993-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 Gev synchrotron light source facility consisting of a 120 kev electron gun, 50 Mev linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. Figure 1. ALS floor plan. Pairs of neutron and gamma radiation monitors are shown as dots numbered from 1 to 12. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  17. The Advanced Light Source (ALS) Radiation Safety System

    International Nuclear Information System (INIS)

    Ritchie, A.; Oldfather, D.; Lindner, A.

    1993-05-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 GeV synchrotron light source facility consisting of a 120 keV electron gun, 50 MeV linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  18. The Power of Collaboration for Improving Safety in Complex Systems

    International Nuclear Information System (INIS)

    Hart, C. A.

    2016-01-01

    Many potentially hazardous industries involve systems that consist of a complex array of subsystems that must work together effectively in order for the entire system to perform. Often the subsystems are coupled, such that changes in any one subsystem can affect other subsystems. “System Think” refers to an awareness of the impacts throughout a system of changes in any subsystem. The U.S. commercial aviation industry, in its continuing endeavor to improve safety, uses a collaborative approach to accomplish System Think— bringing all of the key parts of the industry together to work in a collaborative manner to identify and address potential safety concerns. The collaborative approach resulted in an 83% reduction in the fatal accident rate in only 10 years. It also demonstrated that, contrary to conventional wisdom that safety improvements usually hurt productivity, safety improvements that result from a collaborative approach can simultaneously improve productivity. Last but not least, it minimised one of the continuing challenges of making changes in complex systems, which is unintended consequences. The purpose of this presentation is to describe the collaborative approach and to discuss its transferability to other potentially hazardous industries that are seeking to manage their risks more efficiently and effectively. (author)

  19. Process Control Systems in the Chemical Industry: Safety vs. Security

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Hahn; Thomas Anderson

    2005-04-01

    Traditionally, the primary focus of the chemical industry has been safety and productivity. However, recent threats to our nation’s critical infrastructure have prompted a tightening of security measures across many different industry sectors. Reducing vulnerabilities of control systems against physical and cyber attack is necessary to ensure the safety, security and effective functioning of these systems. The U.S. Department of Homeland Security has developed a strategy to secure these vulnerabilities. Crucial to this strategy is the Control Systems Security and Test Center (CSSTC) established to test and analyze control systems equipment. In addition, the CSSTC promotes a proactive, collaborative approach to increase industry's awareness of standards, products and processes that can enhance the security of control systems. This paper outlines measures that can be taken to enhance the cybersecurity of process control systems in the chemical sector.

  20. Safety implications of using programmable digital computers in nuclear safety and control systems

    International Nuclear Information System (INIS)

    Adams, D.M.; Rohrdanz, R.R.

    1982-01-01

    This papers describes the activities being conducted at the Idaho National Engineering Laboratory associated with the use of stored-program computers for protection and control systems. This project has recently been initiated and a preliminary report will be available. The use of computers in plant control and protection (and more generally in system important to safety) represents a major departure from the systems which have been used in the past. The design, development, and audit methods used for these systems are significantly different, thus requiring different skills and different perspectives

  1. 33 CFR 96.230 - What objectives must a safety management system meet?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.230 What objectives must a safety management system meet? The safety management system must: (a) Provide for safe practices in vessel operation... improve safety management skills of personnel ashore and aboard vessels, including preparation for...

  2. Safety system upgrades to a research reactor: A regulatory perspective

    International Nuclear Information System (INIS)

    Lamarre, G.B.; Martin, W.G.

    2003-01-01

    The NRU (National Research Universal) reactor, located at the Chalk River Laboratories of Atomic Energy of Canada Limited (AECL), first achieved criticality November 3, 1957. AECL continues to operate NRU for research to support safety and reliability studies for CANDU reactors and as a major supplier of medical radioisotopes. Following a detailed systematic review and assessment of NRU's design and the condition of its primary systems, AECL formally notified the Canadian Nuclear Safety Commission's (CNSC) predecessor - the Atomic Energy Control Board - in 1992 of its intention to upgrade NRU's safety systems. AECL proposed seven major upgrades to provide improvements in shutdown capability, heat removal, confinement, and reactor monitoring, particularly during and after a seismic event. From a CNSC perspective, these upgrades were necessary to meet modern safety standards. From the start of the upgrades project, the CNSC provided regulatory oversight aimed at ensuring that AECL maintained a structured approach to the upgrades. The elements of the approach include, but are not limited to, the determination of project milestones and target dates; the formalization of the design process and project quality assurance requirements; the requirements for updated documentation, including safety reports, safety notes and commissioning reports; and the approval and authorization process. This paper details, from a regulatory perspective, the structured approach used in approving the design, construction, commissioning and subsequent operation of safety system upgrades for an existing and operating research reactor, including the many challenges faced when attempting to balance the requirements of the upgrades project with AECL's need to keep NRU operating to meet its important research and production objectives. (author)

  3. Rassyn: National radiological safety data management system

    International Nuclear Information System (INIS)

    Domenech Nieves, Haydee; Valdez Ramso, Maryzury; Jova Sed, Luis; De la Fuente, Andres

    1996-01-01

    The paper describes the menu, screens data files, programs and classifications of the systems, for keeping a record of their institutions, inspection and authorization, the personal register of incidents and accidents, and the national inventory of radiation protection sources and equipment. By making use of it, a comparison can be made of existing data of a practice with its requirements and a questionnaire of the inspection, (Checking list), the development and results of the inspection can be reported on, the program and notification of the inspection can be prepared and the information on the radiological situation- whether at a national or at a territorial level- can be evaluated

  4. Immobilisation versus immediate mobilisation after intrauterine insemination: randomised controlled trial

    NARCIS (Netherlands)

    Custers, Inge M.; Flierman, Paul A.; Maas, Pettie; Cox, Tessa; van Dessel, Thierry J. H. M.; Gerards, Mariette H.; Mochtar, Monique H.; Janssen, Catharina A. H.; van der Veen, Fulco; Mol, Ben Willem J.

    2009-01-01

    Objective To evaluate the effectiveness of 15 minutes of immobilisation versus immediate mobilisation after intrauterine insemination. Design Randomised controlled trial. Setting One academic teaching hospital and six non-academic teaching hospitals. Participants Women having intrauterine

  5. Complications of the intrauterine device in nulliparous and parous women.

    NARCIS (Netherlands)

    Veldhuis, H.M.; Vos, A.G.; Lagro-Janssen, A.L.M.

    2004-01-01

    OBJECTIVES: The intrauterine device (IUD) is still related to pelvic inflammatory disease (PID), pregnancy, expulsion, perforation and menstrual problems, particularly in nulliparous women. We aimed to study the complications and symptoms of the intrauterine device in general practice, particularly

  6. Evaluation of food safety management systems in Serbian dairy industry

    Directory of Open Access Journals (Sweden)

    Igor Tomašević

    2016-01-01

    Full Text Available This paper reports incentives, costs, difficulties and benefits of food safety management systems implementation in the Serbian dairy industry. The survey involved 27 food business operators with the national milk and dairy market share of 65 %. Almost two thirds of the assessed dairy producers (70.4 % claimed that they had a fully operational and certified HACCP system in place, while 29.6 % implemented HACCP, but had no third party certification. ISO 22000 was implemented and certified in 29.6 % of the companies, while only 11.1 % had implemented and certified IFS standard. The most important incentive for implementing food safety management systems for Serbian dairy producers was to increase and improve safety and quality of dairy products. The cost of product investigation/analysis and hiring external consultants were related to the initial set-up of food safety management system with the greatest importance. Serbian dairy industry was not greatly concerned by the financial side of implementing food safety management systems due to the fact that majority of prerequisite programmes were in place and regularly used by almost 100 % of the producers surveyed. The presence of competency gap between the generic knowledge for manufacturing food products and the knowledge necessary to develop and implement food safety management systems was confirmed, despite the fact that 58.8 % of Serbian dairy managers had university level of education. Our study brings about the innovation emphasizing the attitudes and the motivation of the food production staff as the most important barrier for the development and implementation of HACCP. The most important identified benefit was increased safety of dairy products with the mean rank scores of 6.85. The increased customer confidence and working discipline of staff employed in food processing were also found as important benefits of implementing/operating HACCP. The study shows that the level of HACCP

  7. Nickel-iron battery system safety

    Science.gov (United States)

    Saltat, R. C.

    1984-06-01

    Eagle-Picher Industries conducted a literature search and experimental tests to characterize the generated flow rates of gaseous hydrogen (GH2) and gaseous oxygen (GO2) from an electrical vehicle (EV) nickel iron battery system. The resulting gassing rates were used to experimentally evaluate the flame quenching capabilities of several candidate devices to prevent the propagation of flame within batteries having central watering/venting systems. The battery generated hydrogen (GH2) and oxygen (GO2) gasses were measured for a complete charge and discharge cycle. The data correlates well with accepted theory during strong overcharge conditions indicating that the measurements are valid for other portions of the cycle. Tests have confirmed that the gas mixture in the cells is always flammable regardless of the battery status. Research of flame arrestor literature yielded little information regarding their operation with hydrogen-oxygen mixtures. It was indicated that a conventional flame arrestor would not be effective over the broad spectrum of gassing conditions presented by a nickel iron battery.

  8. Forgotten intrauterine device contributing to infertility

    Directory of Open Access Journals (Sweden)

    Gabriel O. Igberase

    2011-10-01

    Full Text Available The aim of the study is to show that long standing forgotten intrauterine device contributes to infertility, reporting three cases presented at Central Hospital Warri, Nigeria, a government tertiary health center. Three cases of forgotten intrauterine contraceptive device (IUCD contributing to infertility were seen. Two were inserted for contraceptive reasons while one was inserted while being managed for uterine synechae. Health care providers should ensure proper documentation of all procedures carried out, adequate counseling which should include taking an informed consent and also ensuring both short and long term follow up of their clients. Also all patients being evaluated for infertility and clients with past history of intrauterine device must have a speculum examination and ultrasound scan carried out.

  9. An approach for assessing ALWR passive safety system reliability

    International Nuclear Information System (INIS)

    Hake, T.M.

    1991-01-01

    Many of the advanced light water reactor (ALWR) concepts proposed for the next generation of nuclear power plants rely on passive rather than active systems to perform safety functions. Despite the reduced redundancy of the passive systems as compared to active systems in current plants, the assertion is that the overall safety of the plant is enhanced due to the much higher expected reliability of the passive systems. In order to investigate this assertion, a study is being conducted at Sandia National Laboratories to evaluate the reliability of ALWR passive safety features in the context of probabilistic risk assessment (PRA). The purpose of this paper is to provide a brief overview of the approach to this study. The quantification of passive system reliability is not as straightforward as for active systems, due to the lack of operating experience, and to the greater uncertainty in the governing physical phenomena. Thus, the adequacy of current methods for evaluating system reliability must be assessed, and alternatives proposed if necessary. For this study, the Westinghouse Advanced Passive 600 MWe reactor (AP600) was chosen as the advanced reactor for analysis, because of the availability of AP600 design information. This study compares the reliability of AP600 emergency cooling system with that of corresponding systems in a current generation reactor

  10. Electronic clinical safety reporting system: a benefits evaluation.

    Science.gov (United States)

    Elliott, Pamela; Martin, Desmond; Neville, Doreen

    2014-06-11

    Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use

  11. The achievement and assessment of safety in systems containing software

    International Nuclear Information System (INIS)

    Ball, A.; Dale, C.J.; Butterfield, M.H.

    1986-01-01

    In order to establish confidence in the safe operation of a reactor protection system, there is a need to establish, as far as it is possible, that: (i) the algorithms used are correct; (ii) the system is a correct implementation of the algorithms; and (iii) the hardware is sufficiently reliable. This paper concentrates principally on the second of these, as it applies to the software aspect of the more accurate and complex trip functions to be performed by modern reactor protection systems. In order to engineer safety into software, there is a need to use a development strategy which will stand a high chance of achieving a correct implementation of the trip algorithms. This paper describes three broad methodologies by which it is possible to enhance the integrity of software: fault avoidance, fault tolerance and fault removal. Fault avoidance is concerned with making the software as fault free as possible by appropriate choice of specification, design and implementation methods. A fault tolerant strategy may be advisable in many safety critical applications, in order to guard against residual faults present in the software of the installed system. Fault detection and removal techniques are used to remove as many faults as possible of those introduced during software development. The paper also discusses safety and reliability assessment as it applies to software, outlining the various approaches available. Finally, there is an outline of a research project underway in the UKAEA which is intended to assess methods for developing and testing safety and protection systems involving software. (author)

  12. TEPSS - Technology Enhancement for Passive Safety Systems

    International Nuclear Information System (INIS)

    Hart, J.; Slegers, W.J.M.; Boer, S.L. de; Huggenberger, M.; Lopez Jimenez, J.; Munoz-Cabo Gonzalez, J.L.; Reventos Puigjaner, F.

    2000-01-01

    The objective of the TEPSS project was to make significant additions to the technology base of the European Simplified Boiling Water Reactor (ESBWR). The project focused on mixing and stratification phenomena in large water pools, passive decay heat removal from containments, and effects of aerosol deposition inside a passive heat exchanger. The PSI experimental facility LINX (Large-scale Investigation of Natural Circulation and Mixing) has been used to investigate venting of steam and steam-noncondensable gas mixtures into water pools. The test revealed that no significant steam bypass could be detected when injecting a mixture of steam or air and that mixing was very efficient. In addition to the tests, 3-D numerical computations and initial model development have been performed to study the behaviour of bubble plumes in water pools. The major part of the TEPSS project studied selective aspects of the response technology of modem pressure-suppression type containment designs and of passive-type decay heat removal systems. The work included an experimental phase using the large-scale experimental facility PANDA (Passive Nachwaermeabfuhr und Druckabbau), operated by PSI, where eight experiments successfully have been executed to test the performance of the ESBWR containment configuration. The PANDA tests have been analysed successfully using thermalhydraulic system analysis codes and 3-D CFD codes. The AIDA (Aerosol Impaction and Deposition Analysis) experimental facility of PSI has been used to investigate the degradation of passive decay heat removal due to fission product aerosols deposited on the inside surfaces of the PCC (Passive Containment Cooler) heat exchanger tubes. The one test performed revealed that the degradation of the heat transfer in the PCC tubes due to the deposition of aerosols reached about 20%. The test has been analysed using the MELCOR severe accident analysis code. (author)

  13. Japanese simplified light water reactors using passive safety systems

    International Nuclear Information System (INIS)

    Oka, Y.; Naitoh, M.; Kiyose, R.

    1991-01-01

    Concepts fo small and medium-sized light water reactors for the next generation have been developed by Japanese nuclear plant vendors. These are called HSBWR and MSPWR. The basic design philosophy was (1) to improve economy to avoid scale demerits mainly by decreasing the capital costs of construction and (2) to improve safety margin by incorporating passive safety systems. Both HSBWR and MSPWR utilize active components as part of safety systems, but their role is greatly limited, whereas passive components are widely incorporated. The grace period of HSBWR is one day of infinite as an option for emergency core cooling, and three days for residual heat removal. As for MSPWR, it is three days for both events. For both HSBWR and MSPWR, improvement of economy is largely contributed by short construction period less than three years, continuous operation period of two years, and periodical inspection time required less than 40 days. (author)

  14. Use of modern software - based instrumentation in safety critical systems

    International Nuclear Information System (INIS)

    Emmett, J.; Smith, B.

    2005-01-01

    Many Nuclear Power Plants are now ageing and in need of various degrees of refurbishment. Installed instrumentation usually uses out of date 'analogue' technology and is often no longer available in the market place. New technology instrumentation is generally un-qualified for nuclear use and specifically the new 'smart' technology contains 'firmware', (effectively 'soup' (Software of Uncertain Pedigree)) which must be assessed in accordance with relevant safety standards before it may be used in a safety application. Particular standards are IEC 61508 [1] and the British Energy (BE) PES (Programmable Electronic Systems) guidelines EPD/GEN/REP/0277/97. [2] This paper outlines a new instrument evaluation system, which has been developed in conjunction with the UK Nuclear Industry. The paper concludes with a discussion about on-line monitoring of Smart instrumentation in safety critical applications. (author)

  15. Ectopic Intrauterine Device in the Bladder of a Pregnant Woman

    Science.gov (United States)

    Kurdoglu, Zehra; Ceylan, Kadir; Kurdoglu, Mertihan; Guler, Ayse; Sahin, Hanim Guler

    2010-01-01

    Background. Uterine perforation and transvesical migration of an intrauterine device are rare complications. Case. A 28-year-old woman who had an intrauterine device was admitted to our outpatient clinic with complaints of amenorrhea lasting 5 weeks and pelvic pain lasting a year. Transvaginal ultrasonography revealed embedding of the intrauterine device in the bladder. The misplaced device was removed by laparotomy. Conclusion. The followup of intrauterine device localization with transvaginal ultrasonography is essential for early detection of possible serious complications. PMID:20811600

  16. Can cyclist safety be improved with intelligent transport systems?

    Science.gov (United States)

    Silla, Anne; Leden, Lars; Rämä, Pirkko; Scholliers, Johan; Van Noort, Martijn; Bell, Daniel

    2017-08-01

    In recent years, Intelligent Transport Systems (ITS) have assisted in the decrease of road traffic fatalities, particularly amongst passenger car occupants. Vulnerable Road Users (VRUs) such as pedestrians, cyclists, moped riders and motorcyclists, however, have not been that much in focus when developing ITS. Therefore, there is a clear need for ITS which specifically address VRUs as an integrated element of the traffic system. This paper presents the results of a quantitative safety impact assessment of five systems that were estimated to have high potential to improve the safety of cyclists, namely: Blind Spot Detection (BSD), Bicycle to Vehicle communication (B2V), Intersection safety (INS), Pedestrian and Cyclist Detection System+Emergency Braking (PCDS+EBR) and VRU Beacon System (VBS). An ex-ante assessment method proposed by Kulmala (2010) targeted to assess the effects of ITS for cars was applied and further developed in this study to assess the safety impacts of ITS specifically designed for VRUs. The main results of the assessment showed that all investigated systems affect cyclist safety in a positive way by preventing fatalities and injuries. The estimates considering 2012 accident data and full penetration showed that the highest effects could be obtained by the implementation of PCDS+EBR and B2V, whereas VBS had the lowest effect. The estimated yearly reduction in cyclist fatalities in the EU-28 varied between 77 and 286 per system. A forecast for 2030, taking into accounts the estimated accident trends and penetration rates, showed the highest effects for PCDS+EBR and BSD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Segmentation Scheme for Safety Enhancement of Engineered Safety Features Component Control System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangseok; Sohn, Kwangyoung [Korea Reliability Technology and System, Daejeon (Korea, Republic of); Lee, Junku; Park, Geunok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    Common Caused Failure (CCF) or undetectable failure would adversely impact safety functions of ESF-CCS in the existing nuclear power plants. We propose the segmentation scheme to solve these problems. Main function assignment to segments in the proposed segmentation scheme is based on functional dependency and critical function success path by using the dependency depth matrix. The segment has functional independence and physical isolation. The segmentation structure is that prohibit failure propagation to others from undetectable failures. Therefore, the segmentation system structure has robustness to undetectable failures. The segmentation system structure has functional diversity. The specific function in the segment defected by CCF, the specific function could be maintained by diverse control function that assigned to other segments. Device level control signals and system level control signals are separated and also control signal and status signals are separated due to signal transmission paths are allocated independently based on signal type. In this kind of design, single device failure or failures on signal path in the channel couldn't result in the loss of all segmented functions simultaneously. Thus the proposed segmentation function is the design scheme that improves availability of safety functions. In conventional ESF-CCS, the single controller generates the signal to control the multiple safety functions, and the reliability is achieved by multiplication within the channel. This design has a drawback causing the loss of multiple functions due to the CCF (Common Cause Failure) and single failure Heterogeneous controller guarantees the diversity ensuring the execution of safety functions against the CCF and single failure, but requiring a lot of resources like manpower and cost. The segmentation technology based on the compartmentalization and functional diversification decreases the CCF and single failure nonetheless the identical types of

  18. Operational safety system performance alternative to the WANO's indicator

    International Nuclear Information System (INIS)

    Lyra, Moacir

    2002-01-01

    One of the operational safety performance indicators recommended by the World Association of Nuclear Operators (WANO) and adopted by Electronuclear is the reliability of the safety systems. The parameter selected to represent this indicator is the average unavailability of the trains of the concerned system. This parameter would be universally representative of the reliability for comparison purpose only if all nuclear power plants were designed within the same redundancy criteria. Considering the diversity of design criteria of the power plants in operation and based on a probabilistic approach, this paper proposes new performance indicators which are comparable regardless the redundancy criteria of the system. A case example applied to a system of the Angra 2 nuclear power plant shows that, even though with the plant in the infancy phase, the performance of the system in the period is very good. (author)

  19. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....

  20. System safety analysis of an autonomous mobile robot

    Energy Technology Data Exchange (ETDEWEB)

    Bartos, R.J.

    1994-08-01

    Analysis of the safety of operating and maintaining the Stored Waste Autonomous Mobile Inspector (SWAMI) II in a hazardous environment at the Fernald Environmental Management Project (FEMP) was completed. The SWAMI II is a version of a commercial robot, the HelpMate{trademark} robot produced by the Transitions Research Corporation, which is being updated to incorporate the systems required for inspecting mixed toxic chemical and radioactive waste drums at the FEMP. It also has modified obstacle detection and collision avoidance subsystems. The robot will autonomously travel down the aisles in storage warehouses to record images of containers and collect other data which are transmitted to an inspector at a remote computer terminal. A previous study showed the SWAMI II has economic feasibility. The SWAMI II will more accurately locate radioactive contamination than human inspectors. This thesis includes a System Safety Hazard Analysis and a quantitative Fault Tree Analysis (FTA). The objectives of the analyses are to prevent potentially serious events and to derive a comprehensive set of safety requirements from which the safety of the SWAMI II and other autonomous mobile robots can be evaluated. The Computer-Aided Fault Tree Analysis (CAFTA{copyright}) software is utilized for the FTA. The FTA shows that more than 99% of the safety risk occurs during maintenance, and that when the derived safety requirements are implemented the rate of serious events is reduced to below one event per million operating hours. Training and procedures in SWAMI II operation and maintenance provide an added safety margin. This study will promote the safe use of the SWAMI II and other autonomous mobile robots in the emerging technology of mobile robotic inspection.

  1. System safety analysis of an autonomous mobile robot

    International Nuclear Information System (INIS)

    Bartos, R.J.

    1994-01-01

    Analysis of the safety of operating and maintaining the Stored Waste Autonomous Mobile Inspector (SWAMI) II in a hazardous environment at the Fernald Environmental Management Project (FEMP) was completed. The SWAMI II is a version of a commercial robot, the HelpMate trademark robot produced by the Transitions Research Corporation, which is being updated to incorporate the systems required for inspecting mixed toxic chemical and radioactive waste drums at the FEMP. It also has modified obstacle detection and collision avoidance subsystems. The robot will autonomously travel down the aisles in storage warehouses to record images of containers and collect other data which are transmitted to an inspector at a remote computer terminal. A previous study showed the SWAMI II has economic feasibility. The SWAMI II will more accurately locate radioactive contamination than human inspectors. This thesis includes a System Safety Hazard Analysis and a quantitative Fault Tree Analysis (FTA). The objectives of the analyses are to prevent potentially serious events and to derive a comprehensive set of safety requirements from which the safety of the SWAMI II and other autonomous mobile robots can be evaluated. The Computer-Aided Fault Tree Analysis (CAFTA copyright) software is utilized for the FTA. The FTA shows that more than 99% of the safety risk occurs during maintenance, and that when the derived safety requirements are implemented the rate of serious events is reduced to below one event per million operating hours. Training and procedures in SWAMI II operation and maintenance provide an added safety margin. This study will promote the safe use of the SWAMI II and other autonomous mobile robots in the emerging technology of mobile robotic inspection

  2. System safety and the Coast Guard Lighter-Than-Air system project

    OpenAIRE

    Danaher, Patrick Joseph

    1983-01-01

    Approved for public release; distribution is unlimited The Coast Guard is evaluating the potential of Lighter-Than-Air (LTA) vehicles for possible future Coast Guard utilization. Progress of the project is explored. Safety science is an emerging field particularly of value in the historically hazardous realm of aviation. The System Safety Concept as applicable to major project development is examined. One of the fundamental tasks of system safety management is to identify possible haza...

  3. Performance scorecard for occupational safety and health management systems

    Directory of Open Access Journals (Sweden)

    Hernâni Veloso Neto

    2012-06-01

    Full Text Available The pro-active and systematic search for best performances should be the two assumptions of any management system, so safety and health management in organizations must also be guided by these same precepts. However, the scientific production evidences that the performance evaluation processes in safety and health continue to be guided, in their essence, by intermittency, reactivity and negativity, which are not consistent with the assumptions referenced above. Therefore, it is essential that health and safety at work management systems (HSW MS are structured from an active and positive viewpoint, focusing on continuous improvement. This implies considering performance evaluation processes that incorporate, on the one hand, monitoring, measuring and verification procedures, and on the other hand, structured matrixes of results that capture the key factors of success, by mobilizing both reactive and proactive indicators. One of the instruments that can fulfill these precepts of health and safety performance evaluation is the SafetyCard, a performance scorecard for HSW MS that we developed and will seek to outline and demonstrate over this paper.

  4. Integration of data from a safety net health care system into the Vaccine Safety Datalink.

    Science.gov (United States)

    Hambidge, Simon J; Ross, Colleen; Shoup, Jo Ann; Wain, Kris; Narwaney, Komal; Breslin, Kristin; Weintraub, Eric S; McNeil, Michael M

    2017-03-01

    In 2013 the Institute of Medicine suggested that the Vaccine Safety DataLink (VSD) should broaden its population by including data of more patients from low income and racially and ethnically diverse backgrounds. In response, Kaiser Permanente Colorado (KPCO) partnered with Denver Health (DH), an integrated safety net health care system, to explore the integration of DH data. We compared three different methods (reference date of September 1, 2013): "Empanelment" (any patient who has had a primary care visit in the past 18months), "Proxy-enrollment" (two health care visits in 3years separated by 90days), and "Enrollment" in a managed care plan. For each of these methods, we compared cohort size, vaccination rates, socio-demographic characteristics, and health care utilization. The empaneled population at DH provided the best comparison to KPCO. DH's empaneled population was 111,330 (57,173 adults; 54,157 children), while KPCO had 436,290 empaneled patients (336,462 adults; 99,828 children). Vaccination rates in both health care systems for empaneled patients were comparable. Two year-old up-to-date coverage rates were 83.2% (KPCO) and 86.9% (DH); rates for adolescent Tdap and MCV4 were 85.5% (KPCO) and 90.6% (DH). There were significant differences in the two populations in age, gender, race, preferred language, and % Federal Poverty Level (FPL) (DH 70.7%safety net health care system that does not have a uniform managed care population into the VSD, and to compare vaccination rates, socio-demographic characteristics, and health care utilization across the two systems. The KPCO-DH collaboration may serve as a model for incorporating data from a safety net healthcare system into the VSD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Quality and safety implications of emergency department information systems.

    Science.gov (United States)

    Farley, Heather L; Baumlin, Kevin M; Hamedani, Azita G; Cheung, Dickson S; Edwards, Michael R; Fuller, Drew C; Genes, Nicholas; Griffey, Richard T; Kelly, John J; McClay, James C; Nielson, Jeff; Phelan, Michael P; Shapiro, Jason S; Stone-Griffith, Suzanne; Pines, Jesse M

    2013-10-01

    The Health Information Technology for Economic and Clinical Health Act of 2009 and the Centers for Medicare & Medicaid Services "meaningful use" incentive programs, in tandem with the boundless additional requirements for detailed reporting of quality metrics, have galvanized hospital efforts to implement hospital-based electronic health records. As such, emergency department information systems (EDISs) are an important and unique component of most hospitals' electronic health records. System functionality varies greatly and affects physician decisionmaking, clinician workflow, communication, and, ultimately, the overall quality of care and patient safety. This article is a joint effort by members of the Quality Improvement and Patient Safety Section and the Informatics Section of the American College of Emergency Physicians. The aim of this effort is to examine the benefits and potential threats to quality and patient safety that could result from the choice of a particular EDIS, its implementation and optimization, and the hospital's or physician group's approach to continuous improvement of the EDIS. Specifically, we explored the following areas of potential EDIS safety concerns: communication failure, wrong order-wrong patient errors, poor data display, and alert fatigue. Case studies are presented that illustrate the potential harm that could befall patients from an inferior EDIS product or suboptimal execution of such a product in the clinical environment. The authors have developed 7 recommendations to improve patient safety with respect to the deployment of EDISs. These include ensuring that emergency providers actively participate in selection of the EDIS product, in the design of processes related to EDIS implementation and optimization, and in the monitoring of the system's ongoing success or failure. Our recommendations apply to emergency departments using any type of EDIS: custom-developed systems, best-of-breed vendor systems, or enterprise systems

  6. The effect of using road safety equipment and systems and ...

    African Journals Online (AJOL)

    In the present communities transportation is a critical component of human life, and one of the main categories in the specification transportation system is the subject of safety. Considering the number of road accidents and deaths caused by it, unfortunately Iran is at the top of countries with the highest number of deaths in ...

  7. Designing the CRT-based safety parameter display system

    International Nuclear Information System (INIS)

    Frankel, C.L.; Schack, K.A.

    1983-01-01

    The conceptual development and design of Safety Parameter Display System (SPDS) CRT displays and graphics is discussed in this paper. Some of the topics addressed include fulfilling the requirements of NUREG 0696, operator input to the design process, and successful display configurations. A methodology is presented to guide the engineer/operator team through the development of displays

  8. Food safety management systems performance in the lamb production chain

    NARCIS (Netherlands)

    Oses, S.M.; Luning, P.A.; Jacxsens, L.; Jaime, I.; Rovira, J.

    2012-01-01

    This study describes a performance measurement of implemented food safety management system (FSMS) along the lamb chain using an FSMS-diagnostic instrument (FSMS-DI) and a Microbiological Assessment Scheme (MAS). Three slaughterhouses, 1 processing plant and 5 butcher shops were evaluated. All the

  9. Toxic Substances Registry System Index of Material Safety Data Sheets

    Science.gov (United States)

    1997-01-01

    The July 1997 revision of the Index of Material Safety Data Sheets (MSDS) for the Kennedy Space Center (KSC) Toxic Substances Registry System (TSRS) is presented. The MSDS lists toxic substances by manufacturer, trade name, stock number, and distributor. The index provides information on hazards, use, and chemical composition of materials stored at KSC.

  10. Safety of systems for the retention of wastes containing radionuclides

    International Nuclear Information System (INIS)

    1980-11-01

    Information and minimal requirements demanded by CNEN for the emission of the Approval Certificate of the Safety Analysis Report related to system for the retention of wastes containing radionuclide, are established, aiming to assure low radioactivity levels to the environment. (E.G.) [pt

  11. New technique for determining unavailability of computer controlled safety systems

    International Nuclear Information System (INIS)

    Fryer, M.O.; Bruske, S.Z.

    1984-04-01

    The availability of a safety system for a fusion reactor is determined. A fusion reactor processes tritium and requires an Emergency Tritium Cleanup (ETC) system for accidental tritium releases. The ETC is computer controlled and because of its complexity, is an excellent candidate for this analysis. The ETC system unavailability, for preliminary untested software, is calculated based on different assumptions about operator response. These assumptions are: (a) the operator shuts down the system after the first indication of plant failure; (b) the operator shuts down the system after following optimized failure verification procedures; or (c) the operator is taken out of the decision process, and the computer uses the optimized failure verification procedures

  12. An approach for assessing ALWR passive safety system reliability

    International Nuclear Information System (INIS)

    Hake, T.M.

    1991-01-01

    Many advanced light water reactor designs incorporate passive rather than active safety features for front-line accident response. A method for evaluating the reliability of these passive systems in the context of probabilistic risk assessment has been developed at Sandia National Laboratories. This method addresses both the component (e.g. valve) failure aspect of passive system failure, and uncertainties in system success criteria arising from uncertainties in the system's underlying physical processes. These processes provide the system's driving force; examples are natural circulation and gravity-induced injection. This paper describes the method, and provides some preliminary results of application of the approach to the Westinghouse AP600 design

  13. Predictors of non-use of intrauterine contraception among women aged 18–49 years in a general practice setting in the UK

    Directory of Open Access Journals (Sweden)

    Walker SH

    2016-10-01

    Full Text Available Susan H Walker,1 Victoria L Newton,2 Lesley Hoggart,3 Mike J Parker4 1Faculty of Health, Social Care & Education, Anglia Ruskin University, Chelmsford, 2Faculty of Health & Social Care, The Open University, Milton Keynes, 3School of Health, Wellbeing and Social Care, The Open University, Milton Keynes, 4Postgraduate Medical Institute, Anglia Ruskin University, Chelmsford, UK Objectives: Our research examined the barriers to the uptake of intrauterine contraception (IUC by women in a general practice (GP setting in the UK. This study reports predictors of non-use of IUC in this context.Design: We used a mixed method Qual/Quant approach in which the initial qualitative research provides a framework for subsequent larger quantitative surveys. Utilizing findings derived from 30 qualitative interviews, a quantitative survey was developed and distributed to a pragmatic sample of 1,195 women, aged 18–49 years, who were recruited through 32 participating GP practices in an area of England, UK. Outcome measures were percentage of attributes or responses in the sample and use or non-use of IUC. Results were analyzed using descriptive statistical analysis and binary logistic regression, using use/non-use as a binary response variable.Results: Attitudinal variables, which were the strongest predictors of non-use of IUC, were an adverse opinion on long-acting aspect of IUC (odds ratio [OR]=8.34, disliking the thought of IUC inside the body (OR=3.138, concerns about IUC causing difficulties becoming pregnant in the future (OR=2.587, concerns about womb damage (OR=2.224, having heard adverse opinions about levonorgestrel-releasing intrauterine system (Mirena® (OR=2.551, having an adverse opinion of having light, irregular periods (OR=2.382 and, having an adverse opinion of having no periods (OR=2.018.Conclusion: Concerns about the long-acting nature of IUC and persisting concerns about the safety of IUC may act as barriers to its use. Information for

  14. The Management System for Nuclear Installations Safety Guide

    International Nuclear Information System (INIS)

    2009-01-01

    This Safety Guide is applicable throughout the lifetime of a nuclear installation, including any subsequent period of institutional control, until there is no significant residual radiation hazard. For a nuclear installation, the lifetime includes site evaluation, design, construction, commissioning, operation and decommissioning. These stages in the lifetime of a nuclear installation may overlap. This Safety Guide may be applied to nuclear installations in the following ways: (a)To support the development, implementation, assessment and improvement of the management system of those organizations responsible for research, site evaluation, design, construction, commissioning, operation and decommissioning of a nuclear installation; (b)As an aid in the assessment by the regulatory body of the adequacy of the management system of a nuclear installation; (c)To assist an organization in specifying to a supplier, via contractual documentation, any specific element that should be included within the supplier's management system for the supply of products. This Safety Guide follows the structure of the Safety Requirements publication on The Management System for Facilities and Activities, whereby: (a)Section 2 provides recommendations on implementing the management system, including recommendations relating to safety culture, grading and documentation. (b)Section 3 provides recommendations on the responsibilities of senior management for the development and implementation of an effective management system. (c)Section 4 provides recommendations on resource management, including guidance on human resources, infrastructure and the working environment. (d)Section 5 provides recommendations on how the processes of the installation can be specified and developed, including recommendations on some generic processes of the management system. (e)Section 6 provides recommendations on the measurement, assessment and improvement of the management system of a nuclear installation. (f

  15. Safety monitoring in the Vaccine Adverse Event Reporting System (VAERS).

    Science.gov (United States)

    Shimabukuro, Tom T; Nguyen, Michael; Martin, David; DeStefano, Frank

    2015-08-26

    The Centers for Disease Control and Prevention (CDC) and the U.S. Food and Drug Administration (FDA) conduct post-licensure vaccine safety monitoring using the Vaccine Adverse Event Reporting System (VAERS), a spontaneous (or passive) reporting system. This means that after a vaccine is approved, CDC and FDA continue to monitor safety while it is distributed in the marketplace for use by collecting and analyzing spontaneous reports of adverse events that occur in persons following vaccination. Various methods and statistical techniques are used to analyze VAERS data, which CDC and FDA use to guide further safety evaluations and inform decisions around vaccine recommendations and regulatory action. VAERS data must be interpreted with caution due to the inherent limitations of passive surveillance. VAERS is primarily a safety signal detection and hypothesis generating system. Generally, VAERS data cannot be used to determine if a vaccine caused an adverse event. VAERS data interpreted alone or out of context can lead to erroneous conclusions about cause and effect as well as the risk of adverse events occurring following vaccination. CDC makes VAERS data available to the public and readily accessible online. We describe fundamental vaccine safety concepts, provide an overview of VAERS for healthcare professionals who provide vaccinations and might want to report or better understand a vaccine adverse event, and explain how CDC and FDA analyze VAERS data. We also describe strengths and limitations, and address common misconceptions about VAERS. Information in this review will be helpful for healthcare professionals counseling patients, parents, and others on vaccine safety and benefit-risk balance of vaccination. Published by Elsevier Ltd.

  16. Nuclear Power Safety Reporting System. Final evaluation results

    International Nuclear Information System (INIS)

    Finlayson, F.C.; Newton, R.D.

    1986-02-01

    This document presents the results of a study conducted by the US Nuclear Regulatory Commission of an unobtrusive, voluntary, anonymous third-party managed, nonpunitive human factors data gathering system (the Nuclear power Safety Reporting System - NPSRS) for the nuclear electric power production industry. The data to be gathered by the NPSRS are intended for use in identifying and quantifying the factors that contribute to the occurrence of significant safety incidents involving humans in nuclear power plants. The NPSRS has been designed to encourage participation in the System through guarantees of reporter anonymity provided by a third-party organization that would be responsible for NPSRS management. As additional motivation to reporters for contributing data to the NPSRS, conditional waivers of NRC disciplinary action would be provided to individuals. These conditional waivers of immunity would apply to potential violations of NRC regulations that might be disclosed through reports submitted to the System about inadvertent, noncriminal incidents in nuclear plants. This document summarizes the overall results of the study of the NPSRS concept. In it, a functional description of the NPSRS is presented together with a review and assessment of potential problem areas that might be met if the System were implemented. Conclusions and recommendations resulting from the study are also presented. A companion volume (NUREG/CR-4133, Nuclear Power Safety Reporting System: Implementation and Operational Specifications'') presented in detail the elements, requirements, forms, and procedures for implementing and operating the System. 13 refs

  17. Radiation Safety System (RSS) backbones: Design, engineering, fabrication, and installation

    Science.gov (United States)

    Wilmarth, J. E.; Sturrock, J. C.; Gallegos, F. R.

    1998-12-01

    The Radiation Safety System (RSS) backbones are part of an electrical/electronic/mechanical system ensuring safe access and exclusion of personnel to areas at the Los Alamos Neutron Science Center (LANSCE) accelerator. The RSS backbones control the safety-fusible beam plugs which terminate transmission of accelerated ion beams in response to predefined conditions. Any beam or access fault of the backbone inputs will cause insertion of the beam plugs in the low-energy beam transport. The backbones serve the function of tying the beam plugs to the access control systems, beam spill monitoring systems and current-level limiting systems. In some ways the backbones may be thought of as a spinal column with beam plugs at the head and nerve centers along the spinal column. The two linac backbone segments and the experimental area segments form a continuous cable plant over 3500 feet from the beam plugs to the tip on the longest tail. The backbones were installed in compliance with current safety standards, such as installation of the two segments in separate conduits or tray. Monitoring for ground-faults and input wiring verification was an added enhancement to the system. The system has the capability to be tested remotely.

  18. A reliability assessment methodology for the VHTR passive safety system

    International Nuclear Information System (INIS)

    Lee, Hyungsuk; Jae, Moosung

    2014-01-01

    The passive safety system of a VHTR (Very High Temperature Reactor), which has recently attracted worldwide attention, is currently being considered for the design of safety improvements for the next generation of nuclear power plants in Korea. The functionality of the passive system does not rely on an external source of an electrical support system, but on the intelligent use of natural phenomena. Its function involves an ultimate heat sink for a passive secondary auxiliary cooling system, especially during a station blackout such as the case of the Fukushima Daiichi reactor accidents. However, it is not easy to quantitatively evaluate the reliability of passive safety for the purpose of risk analysis, considering the existing active system failure since the classical reliability assessment method cannot be applied. Therefore, we present a new methodology to quantify the reliability based on reliability physics models. This evaluation framework is then applied to of the conceptually designed VHTR in Korea. The Response Surface Method (RSM) is also utilized for evaluating the uncertainty of the maximum temperature of nuclear fuel. The proposed method could contribute to evaluating accident sequence frequency and designing new innovative nuclear systems, such as the reactor cavity cooling system (RCCS) in VHTR to be designed and constructed in Korea.

  19. Radiation safety system (RSS) backbones: Design, engineering, fabrication and installation

    International Nuclear Information System (INIS)

    Wilmarth, J.E.; Sturrock, J.C.; Gallegos, F.R.

    1998-01-01

    The Radiation Safety System (RSS) Backbones are part of an electrical/electronic/mechanical system insuring safe access and exclusion of personnel to areas at the Los Alamos Neutron Science Center (LANSCE) accelerator. The RSS Backbones control the safety fusible beam plugs which terminate transmission of accelerated ion beams in response to predefined conditions. Any beam or access fault of the backbone inputs will cause insertion of the beam plugs in the low energy beam transport. The Backbones serve the function of tying the beam plugs to the access control systems, beam spill monitoring systems and current-level limiting systems. In some ways the Backbones may be thought of as a spinal column with beam plugs at the head and nerve centers along the spinal column. The two Linac Backbone segments and experimental area segments form a continuous cable plant over 3,500 feet from beam plugs to the tip on the longest tail. The Backbones were installed in compliance with current safety standards, such as installation of the two segments in separate conduits or tray. Monitoring for ground-faults and input wiring verification was an added enhancement to the system. The system has the capability to be tested remotely

  20. Safety analysis and review system: a Department of Energy safety assurance tool

    International Nuclear Information System (INIS)

    Rosenthal, H.B.

    1981-01-01

    The concept of the Safety Analysis and Review System is not new. It has been used within the Department and its predecessor agencies, Atomic Energy Commission (AEC) and Energy Research and Development Administration (ERDA), for over 20 years. To minimize the risks from nuclear reactor and power plants, the AEC developed a process to support management authorization of each operation through identification and analysis of potential hazards and the measures taken to control them. As the agency evolved from AEC through ERDA to the Department of Energy, its responsibilities were broadened to cover a diversity of technologies, including those associated with the development of fossil, solar, and geothermal energy. Because the safety analysis process had proved effective in a technology of high potential hazard, the Department investigated the applicability of the process to the other technologies. This paper describes the system and discusses how it is implemented within the Department

  1. SAFETY

    CERN Multimedia

    M. Plagge, C. Schaefer and N. Dupont

    2013-01-01

    Fire Safety – Essential for a particle detector The CMS detector is a marvel of high technology, one of the most precise particle measurement devices we have built until now. Of course it has to be protected from external and internal incidents like the ones that can occur from fires. Due to the fire load, the permanent availability of oxygen and the presence of various ignition sources mostly based on electricity this has to be addressed. Starting from the beam pipe towards the magnet coil, the detector is protected by flooding it with pure gaseous nitrogen during operation. The outer shell of CMS, namely the yoke and the muon chambers are then covered by an emergency inertion system also based on nitrogen. To ensure maximum fire safety, all materials used comply with the CERN regulations IS 23 and IS 41 with only a few exceptions. Every piece of the 30-tonne polyethylene shielding is high-density material, borated, boxed within steel and coated with intumescent (a paint that creates a thick co...

  2. A Safety Ensuring Mechanism for Holonic Manufacturing Systems

    Science.gov (United States)

    Tamura, Shinsuke; Yanase, Tatsuro; Nishi, Naoya

    This paper discusses a mechanism to ensure safe behaviors of HMSs (Holonic Manufacturing Systems). The change from low-variety high-volume to high-variety low-volume production requires highly flexible and adaptive manufacturing systems. Multi agent systems, in which decisions are made through cooperation among autonomous and cooperative elements, fulfill these requirements by exploiting full abilities of individual elements while eliminating various bottlenecks that exist in conventional systems. However, highly adaptive features induce non-deterministic behaviors of systems, and make it difficult to adopt multi agent systems as primary bases of manufacturing systems. In order to apply these systems to large and complicated applications, mechanisms that make their behaviors more predictable are essential. HMSs are a kind of multi agent systems, and an HMS safety ensuring mechanism proposed here is one of the attempts to make behaviors of multi agent systems more predictable.

  3. Manufacture of Platform Prototype for Digital Safety System

    International Nuclear Information System (INIS)

    Lee, S. Y.; Kim, J. S.; Kim, J. M.

    2010-01-01

    Unit controller is a basic unit of digital safety system platform prototype. The typical unit controller is comprised of CPB(CPU board), CMB(communication board), AIB(Analog input board), AOB(Analog output board), CIB(contact input board), COB(contact output board), and a subrack. It is developed according to H/W development procedure and S/W development life cycle. A digital safety system(for example, plant protection system) is the assemblies of unit controllers. CPB performs the function of each system. DSP(digital signal processor) is built in CPB. CMB is responsible for communication between unit controllers. NSD(Network Switching Device) exchanges data between the unit controllers. Each unit controller of the platform are connected to NSD through CMB. Reliability analyses on unit controller and NSD are performed. These reliability data are used as input of technical validation

  4. Railway automatic safety protection system based on GPS

    Directory of Open Access Journals (Sweden)

    Fu Hai Juan

    2016-01-01

    Full Text Available The automatic protection system of railway safety is designed for the railway construction workers to protect alarm, and the safety protection device by using GPS satellite positioning system to acquire location information of the operating point, through the CTC/TDCS system and computer monitoring system for the running of the train position and the arithmetic distance. Achieving timely and continuously forecasts about the distance of the train which is apart from the operating point to prompt the voice alarm of the approaching train. Using digital technology to realize the function of the traditional analog interphone, eliminates the quality problems of the call. With the GSM-R, mobile wireless transmission channel and terminal technology, it overcomes the restrictions of the analog interphone which influenced by communication distance and more problems of blind areas. Finally to achieve practical, convenient, applicable and adaptable design goals.

  5. The DYLAM approach to systems safety and reliability assessment

    International Nuclear Information System (INIS)

    Amendola, A.

    1988-01-01

    A survey of the principal features and applications of DYLAM (Dynamic Logical Analytical Methodology) is presented, whose basic principles can be summarized as follows: after a particular modelling of the component states, computerized heuristical procedures generate stochastic configurations of the system, whereas the resulting physical processes are simultaneously simulated to give account of the possible interactions between physics and states and, on the other hand, to search for system dangerous configurations and related probabilities. The association of probabilistic techniques for describing the states with physical equations for describing the process results in a very powerful tool for safety and reliability assessment of systems potentially subjected to dangerous incidental transients. A comprehensive picture of DYLAM capability for manifold applications can be obtained by the review of the study cases analyzed (LMFBR core accident, systems reliability assessment, accident simulation, man-machine interaction analysis, chemical reactors safety, etc.)

  6. 14 CFR 415.127 - Flight safety system design and operation data.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety system design and operation... Expendable Launch Vehicle From a Non-Federal Launch Site § 415.127 Flight safety system design and operation... safety review document must describe an applicant's flight safety system and its operation. Part 417...

  7. 30 CFR 285.811 - When must I follow my Safety Management System?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When must I follow my Safety Management System... Environmental and Safety Management, Inspections, and Facility Assessments for Activities Conducted Under SAPs, COPs and GAPs Safety Management Systems § 285.811 When must I follow my Safety Management System? Your...

  8. 33 CFR 96.220 - What makes up a safety management system?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false What makes up a safety management... SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.220 What makes up a safety management system? (a) The...

  9. Safety Metrics for Human-Computer Controlled Systems

    Science.gov (United States)

    Leveson, Nancy G; Hatanaka, Iwao

    2000-01-01

    The rapid growth of computer technology and innovation has played a significant role in the rise of computer automation of human tasks in modem production systems across all industries. Although the rationale for automation has been to eliminate "human error" or to relieve humans from manual repetitive tasks, various computer-related hazards and accidents have emerged as a direct result of increased system complexity attributed to computer automation. The risk assessment techniques utilized for electromechanical systems are not suitable for today's software-intensive systems or complex human-computer controlled systems.This thesis will propose a new systemic model-based framework for analyzing risk in safety-critical systems where both computers and humans are controlling safety-critical functions. A new systems accident model will be developed based upon modem systems theory and human cognitive processes to better characterize system accidents, the role of human operators, and the influence of software in its direct control of significant system functions Better risk assessments will then be achievable through the application of this new framework to complex human-computer controlled systems.

  10. Licensing process for safety-critical software-based systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.; Pulkkinen, U.

    2000-12-01

    System vendors nowadays propose software-based technology even for the most critical safety functions in nuclear power plants. Due to the nature of software faults and the way they cause system failures new methods are needed for the safety and reliability evaluation of these systems. In the research project 'Programmable automation systems in nuclear power plants (OHA)', financed together by the Radiation and Nuclear Safety Authority (STUK), the Ministry of Trade and Industry (KTM) and the Technical Research Centre of Finland (VTT), various safety assessment methods and tools for software based systems are developed and evaluated. As a part of the OHA-work a reference model for the licensing process for software-based safety automation systems is defined. The licensing process is defined as the set of interrelated activities whose purpose is to produce and assess evidence concerning the safety and reliability of the system/application to be licensed and to make the decision about the granting the construction and operation permissions based on this evidence. The parties of the licensing process are the authority, the licensee (the utility company), system vendors and their subcontractors and possible external independent assessors. The responsibility about the production of the evidence in first place lies at the licensee who in most cases rests heavily on the vendor expertise. The evaluation and gauging of the evidence is carried out by the authority (possibly using external experts), who also can acquire additional evidence by using their own (independent) methods and tools. Central issue in the licensing process is to combine the quality evidence about the system development process with the information acquired through tests, analyses and operational experience. The purpose of the licensing process described in this report is to act as a reference model both for the authority and the licensee when planning the licensing of individual applications. Many of the

  11. Licensing process for safety-critical software-based systems

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, P. [VTT Automation, Espoo (Finland); Korhonen, J. [VTT Electronics, Espoo (Finland); Pulkkinen, U. [VTT Automation, Espoo (Finland)

    2000-12-01

    System vendors nowadays propose software-based technology even for the most critical safety functions in nuclear power plants. Due to the nature of software faults and the way they cause system failures new methods are needed for the safety and reliability evaluation of these systems. In the research project 'Programmable automation systems in nuclear power plants (OHA)', financed together by the Radiation and Nuclear Safety Authority (STUK), the Ministry of Trade and Industry (KTM) and the Technical Research Centre of Finland (VTT), various safety assessment methods and tools for software based systems are developed and evaluated. As a part of the OHA-work a reference model for the licensing process for software-based safety automation systems is defined. The licensing process is defined as the set of interrelated activities whose purpose is to produce and assess evidence concerning the safety and reliability of the system/application to be licensed and to make the decision about the granting the construction and operation permissions based on this evidence. The parties of the licensing process are the authority, the licensee (the utility company), system vendors and their subcontractors and possible external independent assessors. The responsibility about the production of the evidence in first place lies at the licensee who in most cases rests heavily on the vendor expertise. The evaluation and gauging of the evidence is carried out by the authority (possibly using external experts), who also can acquire additional evidence by using their own (independent) methods and tools. Central issue in the licensing process is to combine the quality evidence about the system development process with the information acquired through tests, analyses and operational experience. The purpose of the licensing process described in this report is to act as a reference model both for the authority and the licensee when planning the licensing of individual applications

  12. Improving safety margin of LWRs by rethinking the emergency core cooling system criteria and safety system capacity

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youho, E-mail: euo@kaist.ac.kr; Kim, Bokyung, E-mail: bkkim2@kaist.ac.kr; NO, Hee Cheon, E-mail: hcno@kaist.ac.kr

    2016-10-15

    Highlights: • Zircaloy embrittlement criteria can increase to 1370 °C for CP-ECR lower than 13%. • The draft ECCS criteria of U.S. NRC allow less than 5% in power margin. • The Japanese fracture-based criteria allow around 5% in power margin. • Increasing SIT inventory is effective in assuring safety margin for power uprates. - Abstract: This study investigates the engineering compatibility between emergency core cooling system criteria and safety water injection systems, in the pursuit of safety margin increase of light water reactors. This study proposes an acceptable temperature increase to 1370 °C as long as equivalent cladding reacted calculated by the Cathcart–Pawel equation is below 13%, after an extensive literature review. The influence of different ECCS criteria on the safety margin during large break loss of coolant accident is investigated for OPR-1000 by the system code MARS-KS, implemented with the KINS-REM method. The fracture-based emergency core cooling system (ECCS) criteria proposed in this study are shown to enable power margins up to 10%. In the meantime, the draft U.S. NRC’s embrittlement criteria (burnup-sensitive) and Japanese fracture-based criteria are shown to allow less than 5%, and around 5% of power margins, respectively. Increasing safety injection tank (SIT) water inventory is the key, yet convenient, way of assuring safety margin for power increase. More than 20% increase in the SIT water inventory is required to allow 15% power margins, for the U.S. NRC’s burnup-dependent embrittlement criteria. Controlling SIT water inventory would be a useful option that could allow the industrial desire to pursue power margins even under the recent atmosphere of imposing stricter ECCS criteria for the considerable burnup effects.

  13. Evaluation of food safety management systems in Serbian dairy industry

    OpenAIRE

    Tomašević, Igor; Šmigić, Nada; Đekić, Ilija; Zarić, Vlade; Tomić, Nikola; Miocinovic, Jelena; Rajkovic, Andreja

    2016-01-01

    This paper reports incentives, costs, difficulties and benefits of food safety management systems implementation in the Serbian dairy industry. The survey involved 27 food business operators with the national milk and dairy market share of 65 %. Almost two thirds of the assessed dairy producers (70.4 %) claimed that they had a fully operational and certified HACCP system in place, while 29.6 % implemented HACCP, but had no third party certification. ISO 22000 was implemented and certified in ...

  14. Comparative analysis of existing food safety culture evaluation systems

    OpenAIRE

    Jespersen, Lone; Griffiths, Mansel; Wallace, Carol Anne

    2017-01-01

    The purpose of the research was firstly, to analyze existing culture evaluation systems for commonalities and differences in research quality, applied validation strategies, and content. Secondly, to suggest a simple structure of food safety cultural dimensions to help unify the culture evaluation field. To achieve these goals, a comparison of eight culture evaluation models applied to varing degrees in the food industry was conducted. The systems were found to vary significantly in applied v...

  15. Safety assessment for the passive system of the nuclear power plants (NPPs) using safety margin estimation

    International Nuclear Information System (INIS)

    Woo, Tae-Ho; Lee, Un-Chul

    2010-01-01

    The probabilistic safety assessment (PSA) for gas-cooled nuclear power plants has been investigated where the operational data are deficient, because there is not any commercial gas-cooled nuclear power plant. Therefore, it is necessary to use the statistical data for the basic event constructions. Several estimations for the safety margin are introduced for the quantification of the failure frequency in the basic event, which is made by the concept of the impact and affordability. Trend of probability of failure (TPF) and fuzzy converter (FC) are introduced using the safety margin, which shows the simplified and easy configurations for the event characteristics. The mass flow rate in the natural circulation is studied for the modeling. The potential energy in the gravity, the temperature and pressure in the heat conduction, and the heat transfer rate in the internal stored energy are also investigated. The values in the probability set are compared with those of the fuzzy set modeling. Non-linearity of the safety margin is expressed by the fuzziness of the membership function. This artificial intelligence analysis of the fuzzy set could enhance the reliability of the system comparing to the probabilistic analysis.

  16. Systemic Approach to Safety from a Regulatory Perspective

    International Nuclear Information System (INIS)

    Edland, A.

    2016-01-01

    In Sweden and especially in the Swedish oversight of nuclear power plants there has been a strong commitment to the interactions between Man-Technology-Organization (MTO) for many years. Safety issues and the importance of working with these issues have often been highlighted in specific oversight actions. Since 30 years there has been a tradition and a development of experience in Sweden taking a systemic MTO approach to safety. Inspection teams have been created with both psychologists and technical expertise in order to cover the whole MTO perspective during oversight inspections at the nuclear power plants. Safety is based on preventive actions where both technology and human behaviour are taken into account. To do this, it is important to have knowledge about the different factors that influence the performance of individuals, groups and organizations. However, it is also important to remember to not only discuss humans, management and organizations in terms of their limitations, errors and shortcomings but also in terms of their strengths in stopping a chain of events, in learning, inventing and improving. Having an integrated view of safety, focussing on the relations between human, technology and organization (MTO) refers to a systemic perspective on how radiation safety are affected by the relationship between: Human’s abilities and limitations; Technical equipment and the surrounding environment; The organization and the opportunities this provides. The Section of Man-Technology-Organization in the Swedish authority consist today of 12 Human factors specialists with behaviour science education. The section is responsible for the oversight at nuclear power plants in many areas; safety management, leadership and organization, safety culture, competence assurance, fitness for duty, suitability, education and staffing, knowledge management, working conditions, MTO perspective/ergonomics of control room work and plant modification, incident analysis and risk

  17. Prospective Safety Analysis and the Complex Aviation System

    Science.gov (United States)

    Smith, Brian E.

    2013-01-01

    Fatal accident rates in commercial passenger aviation are at historic lows yet have plateaued and are not showing evidence of further safety advances. Modern aircraft accidents reflect both historic causal factors and new unexpected "Black Swan" events. The ever-increasing complexity of the aviation system, along with its associated technology and organizational relationships, provides fertile ground for fresh problems. It is important to take a proactive approach to aviation safety by working to identify novel causation mechanisms for future aviation accidents before they happen. Progress has been made in using of historic data to identify the telltale signals preceding aviation accidents and incidents, using the large repositories of discrete and continuous data on aircraft and air traffic control performance and information reported by front-line personnel. Nevertheless, the aviation community is increasingly embracing predictive approaches to aviation safety. The "prospective workshop" early assessment tool described in this paper represents an approach toward this prospective mindset-one that attempts to identify the future vectors of aviation and asks the question: "What haven't we considered in our current safety assessments?" New causation mechanisms threatening aviation safety will arise in the future because new (or revised) systems and procedures will have to be used under future contextual conditions that have not been properly anticipated. Many simulation models exist for demonstrating the safety cases of new operational concepts and technologies. However the results from such models can only be as valid as the accuracy and completeness of assumptions made about the future context in which the new operational concepts and/or technologies will be immersed. Of course that future has not happened yet. What is needed is a reasonably high-confidence description of the future operational context, capturing critical contextual characteristics that modulate

  18. Development of the Continued Improvement System for Nuclear Safety Culture

    International Nuclear Information System (INIS)

    Park, H. C.; Park, H. G.; Park, Y. W.; Park, J. Y.

    2016-01-01

    It has been found that almost 80 % of the incidents and accidents occurred recently, such as the Fukushima Daiichi disaster and Domestic SBO accident etc. were analyzed to be caused from human errors. (IAEA NES NG-G-2.1) Which strongly claims the importance of the safety culture system. Accordingly, it should be away from a cursory approach like one-off field survey or Snap shop which were being conducted at present for the continued improvement of safety culture. This study introduces an analytical methodology which approaches the generic form of the safety both consciously and unconsciously expressed with behavior, thoughts, and attitude etc. This study was implemented only for open materials such as Inspection report, incidents and accidents reports, QA documents because of the limitation in accessibility to data. More effective use with securing operational data will be possible in future

  19. Development of the safety PLC for plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hwoi; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2005-11-15

    The safety PLC (POSAFE-Q) is developing in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as RTOS and firmware are developed according to safety critical software life cycle. Especially, the formal method is applied to design SRS (Software Requirement Spec.) and SDS (Software Design Specification.) for error-free. The developed software according to software life cycle is verified by independent software V and V team. The overall response time from an input to the outputs shall be 50ms or less. The prototype for the POSAFE-Q was developed and functional testing and equipment qualification tests have been underway.

  20. The elements of a commercial human spaceflight safety reporting system

    Science.gov (United States)

    Christensen, Ian

    2017-10-01

    In its report on the SpaceShipTwo accident the National Transportation Safety Board (NTSB) included in its recommendations that the Federal Aviation Administration (FAA) ;in collaboration with the commercial spaceflight industry, continue work to implement a database of lessons learned from commercial space mishap investigations and encourage commercial space industry members to voluntarily submit lessons learned.; In its official response to the NTSB the FAA supported this recommendation and indicated it has initiated an iterative process to put into place a framework for a cooperative safety data sharing process including the sharing of lessons learned, and trends analysis. Such a framework is an important element of an overall commercial human spaceflight safety system.

  1. Internet of Things Based Combustible Ice Safety Monitoring System Framework

    Science.gov (United States)

    Sun, Enji

    2017-05-01

    As the development of human society, more energy is requires to meet the need of human daily lives. New energies play a significant role in solving the problems of serious environmental pollution and resources exhaustion in the present world. Combustible ice is essentially frozen natural gas, which can literally be lit on fire bringing a whole new meaning to fire and ice with less pollutant. This paper analysed the advantages and risks on the uses of combustible ice. By compare to other kinds of alternative energies, the advantages of the uses of combustible ice were concluded. The combustible ice basic physical characters and safety risks were analysed. The developments troubles and key utilizations of combustible ice were predicted in the end. A real-time safety monitoring system framework based on the internet of things (IOT) was built to be applied in the future mining, which provide a brand new way to monitoring the combustible ice mining safety.

  2. Socio-technological study for establishing comprehensive nuclear safety system

    International Nuclear Information System (INIS)

    Furuta, Kazuo; Kanno, Taro; Yagi, Ekou; Shuto, Yuki

    2003-01-01

    This paper presents an overview and preliminary results of a research project on social-technology for nuclear safety, which started in October 2001. In particular, emergency response preparedness against nuclear disaster and consensus development will be discussed. The architecture of an emergency response simulator will be given, which is for assessing design of disaster prevention systems. A conceptual model of evacuation behavior of a resident has been constructed from analysis of past disaster cases. As for consensus development, deliberation spaces of actual committee meetings were constructed by analyzing transcripts of the meetings based on an opinion schema. A model of consensus development process has been proposed from the traces of participants' opinions over the deliberation spaces. Such a socio-technological approach will be useful not only for nuclear safety but also for safety of non-nuclear domains and human activities of a high hazard potential; it is expected to contribute to establishing risk-aware society of the future. (author)

  3. Man as a safety problem in technical systems

    International Nuclear Information System (INIS)

    Compes, P.C.; Wolff, H.A.

    1980-01-01

    Safety engineering derives its justification from the success achieved in maintaining and enlarging safety, more precisely, from activities aimed at avoiding or preventing damage caused by accidents. Man is not only affected by accidents but is also the cause of accidents, either directly or indirectly, and thus is to be regarded as the actual cause or preventer of accidents. The Second International Summer Symposium of the Society for Safety Engineering (GfS) which was held at Duesseldorf in 1980 brought into focus this aspect and the importance to be attached to the individual man and the whole mankind in the field of accident prevention. 'Man as a safety problem in technical systems' - a great and weighty field of problems, the large extent of which and the complex content of which was to be discussed by the programme with its many different contributions, on the one hand by presenting an outline as completely as possible, and on the other hand by finding further-reaching solutions for at least some problems. This was the purpose of the dialogues held between theory and practice on the one hand, and between safety engineering and, in this case, the human sciences on the other hand. (orig./RW) [de

  4. Institutional failure: are safety management systems the answer?

    International Nuclear Information System (INIS)

    Waddington, J.G.; Lafortune, J.F.; Duffey, R.B.

    2009-01-01

    In spite of an overwhelming number of safety management programs, incidents and accidents that could seemingly, in hindsight, have been prevented, still occur. Institutional failure is seen as a major contributor in almost all cases. With the anticipated significant increase in the number of nuclear plants around the world, a drastic step in the way we manage safety is deemed essential to further reduce the currently already very low rate of accidents to levels that will not cause undue public concern and threaten the success of the nuclear 'renaissance'. To achieve this, many industries have already started implementing a Safety Management System (SMS) approach, aimed at harmonizing, rationalizing and integrating management processes, safety culture and operational risk assessment. This paper discusses the origins and the nature of SMS based in part on the experience of the aviation industry, and shows how SMS is poised to be the next generation in the way the nuclear industry manages safety. It also discusses the need for better direct measures of risk to demonstrate the success of SMS implementation. (author)

  5. Using fuzzy self-organising maps for safety critical systems

    International Nuclear Information System (INIS)

    Kurd, Zeshan; Kelly, Tim P.

    2007-01-01

    This paper defines a type of constrained artificial neural network (ANN) that enables analytical certification arguments whilst retaining valuable performance characteristics. Previous work has defined a safety lifecycle for ANNs without detailing a specific neural model. Building on this previous work, the underpinning of the devised model is based upon an existing neuro-fuzzy system called the fuzzy self-organising map (FSOM). The FSOM is type of 'hybrid' ANN which allows behaviour to be described qualitatively and quantitatively using meaningful expressions. Safety of the FSOM is argued through adherence to safety requirements-derived from hazard analysis and expressed using safety constraints. The approach enables the construction of compelling (product-based) arguments for mitigation of potential failure modes associated with the FSOM. The constrained FSOM has been termed a 'safety critical artificial neural network' (SCANN). The SCANN can be used for non-linear function approximation and allows certified learning and generalisation for high criticality roles. A discussion of benefits for real-world applications is also presented

  6. Evaluating the effectiveness of active vehicle safety systems.

    Science.gov (United States)

    Jeong, Eunbi; Oh, Cheol

    2017-03-01

    Advanced vehicle safety systems have been widely introduced in transportation systems and are expected to enhance traffic safety. However, these technologies mainly focus on assisting individual vehicles that are equipped with them, and less effort has been made to identify the effect of vehicular technologies on the traffic stream. This study proposed a methodology to assess the effectiveness of active vehicle safety systems (AVSSs), which represent a promising technology to prevent traffic crashes and mitigate injury severity. The proposed AVSS consists of longitudinal and lateral vehicle control systems, which corresponds to the Level 2 vehicle automation presented by the National Highway Safety Administration (NHTSA). The effectiveness evaluation for the proposed technology was conducted in terms of crash potential reduction and congestion mitigation. A microscopic traffic simulator, VISSIM, was used to simulate freeway traffic stream and collect vehicle-maneuvering data. In addition, an external application program interface, VISSIM's COM-interface, was used to implement the AVSS. A surrogate safety assessment model (SSAM) was used to derive indirect safety measures to evaluate the effectiveness of the AVSS. A 16.7-km freeway stretch between the Nakdong and Seonsan interchanges on Korean freeway 45 was selected for the simulation experiments to evaluate the effectiveness of AVSS. A total of five simulation runs for each evaluation scenario were conducted. For the non-incident conditions, the rear-end and lane-change conflicts were reduced by 78.8% and 17.3%, respectively, under the level of service (LOS) D traffic conditions. In addition, the average delay was reduced by 55.5%. However, the system's effectiveness was weakened in the LOS A-C categories. Under incident traffic conditions, the number of rear-end conflicts was reduced by approximately 9.7%. Vehicle delays were reduced by approximately 43.9% with 100% of market penetration rate (MPR). These results

  7. Nuclear power systems: Their safety. Current issue review

    International Nuclear Information System (INIS)

    Myers, L.C.

    1994-04-01

    Human beings utilize energy in many forms and from a variety of sources. A number of countries have chosen nuclear-electric generation as a component of their energy system. At the end of 1992, there were 419 power reactors operating in 29 countries, accounting for more than 15% of the world's production of electricity. In 1992, 13 countries derived at least 25% of their electricity from nuclear units, with Lithuania leading at just over 78%, followed closely by France at 72%. In the same year, Canada produced about 16% of its electricity from nuclear units. Some 53 power reactors are under construction in 14 countries outside the former USSR. Within the ex-USSR countries, six new reactors are currently under construction. No human endeavour carries the guarantee of perfect safety and the question of whether of not nuclear-electric generation represents an 'acceptable' risk to society has long been vigorously debated. Until the events of late April 1986 in the then Soviet Union, nuclear safety had indeed been an issue for discussion, for some concern, but not for alarm. The accident at the Chernobyl reactor irrevocably changed all that. This disaster brought the matter of nuclear safety into the public mind in a dramatic fashion. Subsequent opening of the ex-Soviet nuclear power program to outside scrutiny has done little to calm people's concerns about the safety of nuclear power in that part of the world. This paper discusses the issue of safety in complex energy systems and provides brief accounts of some of the most serious reactor accidents that have occurred to date, as well as more recent, less dramatic events touching on the safety issue. (author). 7 refs

  8. Sigmoid colocolic fistula caused by intrauterine device migration: a case report.

    Science.gov (United States)

    Weerasekera, Amila; Wijesinghe, Pravin; Nugaduwa, Nilhan

    2014-03-04

    The intrauterine device is a form of contraception with a long duration of action and few systemic side effects. Migration into the abdominal cavity may occur early or years after insertion giving rise to bowel obstruction, perforation, ischemia, mesenteric injury, strictures or fistulae. Colocolic fistula formation is a rare but serious complication of intrauterine device migration, which may lead to difficulties in diagnosis and device retrieval. We report the case of a 29-year-old Sri Lankan woman who became pregnant 5 years after intrauterine device insertion. The device could not be located during pregnancy. She was asymptomatic and defaulted follow up during the antenatal period. She had an uncomplicated vaginal delivery. A subsequent laparotomy for device retrieval failed due to technical difficulties. A repeat laparotomy identified a sigmoid colocolic fistula with adhesions to the fallopian tube. The device was removed and colonic defects primarily closed following which the patient made an uneventful recovery. All translocated intrauterine devices should be removed regardless of type and location. This case illustrates that they may cause complex bowel lesions leading to serious technical difficulties during retrieval. With the increasing use of minimally invasive approaches for intrauterine device retrieval, a low threshold for open surgery in complicated cases is advocated.

  9. The levonorgestrel-releasing intrauterine system is associated with a reduction in dysmenorrhoea and dyspareunia, a decrease in CA 125 levels, and an increase in quality of life in women with suspected endometriosis.

    Science.gov (United States)

    Yucel, Nese; Baskent, Erdem; Karamustafaoglu Balci, Burcin; Goynumer, Gokhan

    2018-01-23

    The aim of this study was to investigate the effectiveness of a levonorgestrel-releasing intrauterine device (LNG-IUS) in the symptomatic relief of pain in women with endometriosis and additionally, to assess the changes in women's life quality and serum cancer antigen (CA) 125 levels. All women who had an LNG-IUS inserted for the treatment of dysmenorrhea, chronic pelvic pain or both for more than six months over a two-year period were included in the study. Each woman was asked to complete questionnaires of the Short Form-36 and visual analogue scales (VAS) in the first visit and the third, sixth, ninth and twelfth months after the LNG-IUS insertion. CA 125 levels were measured at each visit. Forty-five women were included in the study. At the end of 12 months, mean dysmenorrhoea VAS score decreased from 6.13 to 2.88, mean dsyspareunia VAS score from 6.04 to 2.61 and CA 125 level from 50.67 to 22.45. Endometriomas reduced in size in six women (mean size decreased from 31 to 20 mm) and disappeared in three. Several favourable outcomes were found following LNG-IUS insertion: (i) dyspareunia and dysmenorrhoea were clearly reduced; (ii) the size of endometriomas were decreased; (iii) CA 125 levels significantly decreased; (iv) a few women experienced the typical systemic adverse effects of progestogens; however, LNG-IUS-related adverse events were generally tolerable and the discontinuation rate was as low as 6.66% (3/45). © 2018 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  10. Intra-uterine insemination for male subfertility

    NARCIS (Netherlands)

    Bensdorp, A. J.; Cohlen, B. J.; Heineman, M. J.; Vandekerckhove, P.

    2007-01-01

    BACKGROUND: Intra-uterine insemination (IUI) is one of the most frequently used fertility treatments for couples with male subfertility. Its use, especially when combined with ovarian hyperstimulation (OH) has been subject of discussion. Although the treatment itself is less invasive and expensive

  11. Improved reproductive response of sheep in intrauterine ...

    African Journals Online (AJOL)

    Improved reproductive response of sheep in intrauterine insemination program with the use of royal jelly. ... estrus in ewes treated with 100 IU eCG plus 500 mg RJ when compared with the other treatment groups. Keywords: Royal jelly, equine chorionic gonadotropin (eCG), natural progesterone, artificial insemination, ewe ...

  12. Attitudes towards and knowledge about intrauterine contraceptive ...

    African Journals Online (AJOL)

    Background. One of the strategies to reduce maternal mortality includes accessible and appropriate contraceptive services to all women. The intrauterine contraceptive device (IUCD) has been identified as a cheap and effective means of contraception by the South African National Department of Health. Objective.

  13. Prognostic factors affecting outcome of intrauterine insemination ...

    African Journals Online (AJOL)

    Background: There is a recent resurgence in the use of intrauterine insemination (IUI) in Nigeria. However, there is a need for a rational use of the procedure so that couples do not waste time and money on ineffective therapy if it is not indicated. Objective: The objective of this study was to identify the possible prognostic ...

  14. Intra-uterine hematoma in pregnancy

    DEFF Research Database (Denmark)

    Glavind, K; Nøhr, S; Nielsen, P H

    1991-01-01

    In 60 patients with a live fetus and an intra-uterine hematoma (IUH) proven by ultrasonic scanning the outcome of pregnancy was spontaneous abortion in 12% and premature delivery in 10%. No correlation between the outcome of the pregnancy and the maximum size of the hematoma or the week...

  15. Low Cost, Simple, Intrauterine Insemination Procedure with ...

    African Journals Online (AJOL)

    During the last 30 years however, intrauterine insemination has evolved with the introduction of ovulation stimulating protocols and sperm preparation methods taken from assisted reproduction techniques. Costs have risen, but the success rate has not risen to the same extent. We have therefore developed a quite simple ...

  16. Ectopic Pregnancy Coexisting with Intrauterine Pregnancy | Ifenne ...

    African Journals Online (AJOL)

    A pelvic ultrasonography showed a singleton intrauterine pregnancy, a right adnexa mass and fluid in the rectouterine pouch. At laparotomy, a ruptured right ampulary gestation sac and 8 week size uterus were found and a right total salpingectomy done. Postoperative course was uneventful and the patient delivered a live, ...

  17. Case Report - Heterotopic pregnancy following intrauterine ...

    African Journals Online (AJOL)

    She had induction of ovulation with Clomiphene citrate, gonadotropin stimulation (hCG), and intrauterine insemination using donor sperm. The resulting pregnancy ... Presence of corpus luteum cyst of pregnancy in early ultrasound should be an index of suspicious of a possible heterotopic pregnancy. Early diagnosis and ...

  18. Distinguishing intrauterine foetal demise versus abdominal ...

    African Journals Online (AJOL)

    Diagnosis of abdominal pregnancy always poses a clinical dilemma. Transvaginal ultrasound is the ideal radiological procedure in locating these pregnancies. However in resource limited setting, abdominal and pelvic ultrasounds can be the only available yet unreliable modalities for distinguishing intrauterine versus ...

  19. Complications associated with intrauterine contraceptive devices at ...

    African Journals Online (AJOL)

    Background: Intrauterine contraceptive device (IUCD) is one of the reversible methods of contraception. Its use has increased steadily worldwide. However, some women reject it based on presumed complications associated with its use. Aim: To determine the complications reported by women, action taken on the ...

  20. Comparison of genital microbial isolates between intrauterine ...

    African Journals Online (AJOL)

    Background: In the past, the use of intrauterine contraceptive device (IUCD), in particular, Dalkon Shield was found to be associated with increased risk of pelvic infection. Recent literature illustrates that the risk of pelvic infection after insertion of an IUCD is low and that the risk peaks in the 1st month after insertion. We set ...