WorldWideScience

Sample records for intraoperative indocyanine green

  1. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Directory of Open Access Journals (Sweden)

    Akinori Miyata

    Full Text Available Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10 under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases, photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical

  2. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Science.gov (United States)

    Miyata, Akinori; Ishizawa, Takeaki; Kamiya, Mako; Shimizu, Atsushi; Kaneko, Junichi; Ijichi, Hideaki; Shibahara, Junji; Fukayama, Masashi; Midorikawa, Yutaka; Urano, Yasuteru; Kokudo, Norihiro

    2014-01-01

    Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous) was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10) under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases), photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical advances are needed

  3. Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion

    DEFF Research Database (Denmark)

    Degett, Thea Helene; Andersen, Helene Schou; Gögenur, Ismail

    2016-01-01

    PURPOSE: Anastomotic leakage following gastrointestinal surgery remains a frequent and serious complication associated with a high morbidity and mortality. Indocyanine green fluorescence angiography (ICG-FA) is a newly developed technique to measure perfusion intraoperatively. The aim of this paper...... included in the review if they assessed anastomotic perfusion intraoperatively with ICG-FA in order to predict anastomotic leakage in humans. RESULTS: Of 790 screened papers 14 studies were included in this review. Ten studies (n = 916) involved patients with colorectal anastomoses and four studies (n...

  4. Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery.

    Science.gov (United States)

    Sound, Sara; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Berber, Eren

    2015-10-27

    Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery. © The Author(s) 2015.

  5. Indocyanine green for intraoperative localization of ureter.

    Science.gov (United States)

    Siddighi, Sam; Yune, Junchan Joshua; Hardesty, Jeffrey

    2014-10-01

    Intraurethral injection of indocyanine green (ICG; Akorn, Lake Forest, IL) and visualization under near-infrared (NIR) light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Patients were scheduled to undergo robot-assisted laparoscopic sacrocolpopexy. Before the robotic surgery started, the tip of a 6-F ureteral catheter was inserted into the ureteral orifice. Twenty-five milligrams of ICG was dissolved in 10-mL of sterile water and injected through the open catheter. The same procedure was repeated on the opposite side. The ICG reversibly stained the inside lining of the ureter by binding to proteins on urothelial layer. During the course of robotic surgery, the NIR laser on the da Vinci Si surgical robot (Intuitive Surgical, Inc, Sunnyvale, CA) was used to excite ICG molecules, and infrared emission was captured by the da Vinci filtered lens system and electronically converted to green color. Thus, the ureter fluoresced green, which allowed its definitive identification throughout the entire case. In all cases of >10 patients, we were able to visualize bilateral ureters with this technology, even though there was some variation in brightness that depended on the depth of the ureter from the peritoneal surface. For example, in a morbidly obese patient, the ureters were not as bright green. There were no intraoperative or postoperative adverse effects attributable to ICG administration for up to 2 months of observation. In our experience, this novel method of intraurethral ICG injection was helpful to identify the entire course of ureter and allowed a safe approach to tissues that were adjacent to the urinary tract. The advantage of our technique is that it requires the insertion of just the tip of ureteral catheter. Despite our limited cohort of patients, our findings are consistent with previous reports of the excellent safety profile of intravenous and intrabiliary ICG

  6. Relevance of intraoperative indocyanine green injection in breast reconstruction using DIEP procedure for abdominal scars.

    Science.gov (United States)

    Louges, M A; Bellaiche, J; Correia, N; Chiriac, S; François, C

    2016-06-01

    The presence of midline sub-umbilical and/or suprapubic scar can sometimes hinder breast reconstruction using deep inferior epigastric perforator (DIEP) procedure. We report the use of indocyanine green injection in a 60-year-old woman in the context of deep inferior epigastric perforator (DIEP) procedure for unilateral breast reconstruction (bilateral breast cancer) with abdominal scar (midline sub-umbilical scar and Pfannenstiel incision scar). This technique underlines the importance of neoangiogenesis mechanisms and helped simplify the surgical gesture initially planned (in order to ensure volume in spite of the scars as a DIEP procedure with double anastomoses was initially planned). This intraoperative vascular imaging technique is a minimally invasive, simple and quick procedure allowing the precise visualization of vascularized territories. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  8. Intraoperative indocyanine green fluorescent angiography-assisted modified superior gluteal artery perforator flap for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng

    2017-12-01

    Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  9. DIEP flap customization using Fluobeam® indocyanine green tissue perfusion assessment with large previous abdominal scar

    Directory of Open Access Journals (Sweden)

    Michael A. Fallucco

    2017-06-01

    Full Text Available The Fluobeam® is a portable, near-infrared camera that is held and controlled by the surgeon to visualize tissue perfusion using indocyanine green (ICG fluorescence imaging. This case report describes how data obtained from ICG imaging allows intraoperative customization in a previously surgically scarred abdomen during autologous Deep Inferior Epigastric Artery Perforator (DIEP flap bilateral breast reconstruction. The outcome was successful breast mound recreation without fat necrosis.

  10. Intraoperative Detection of Superficial Liver Tumors by Fluorescence Imaging Using Indocyanine Green and 5-aminolevulinic Acid.

    Science.gov (United States)

    Kaibori, Masaki; Matsui, Kosuke; Ishizaki, Morihiko; Iida, Hiroya; Okumura, Tadayoshi; Sakaguchi, Tatsuma; Inoue, Kentaro; Ikeura, Tsukasa; Asano, Hiroaki; Kon, Masanori

    2016-04-01

    Indocyanine green (ICG) and the porphyrin precursor 5-aminolevulinic acid (5-ALA) have been approved as fluorescence imaging agents in the clinical setting. This study evaluated the usefulness of fluorescence imaging with both ICG and 5-ALA for intraoperative identification of latent small liver tumors. There were 48 patients who had main tumors within 5 mm of the liver surface. 5-ALA hydrochloride was orally administered to patients 3 h before surgery. ICG had been intravenously injected within 14 days prior to surgery. Intraoperatively, after visual inspection, manual palpation and ultrasonography fluorescence images of the liver surface were obtained with ICG and 5-ALA prior to resection. With ICG, the sensitivity, specificity and accuracy for detecting the preoperatively identified main tumors were 96%, 50% and 94%, respectively. Twelve latent small tumors were newly detected on the liver surface using ICG, five of which proved to be carcinomas. With 5-ALA, the sensitivity, specificity and accuracy for detecting the main tumors were 57%, 100% and 58%, respectively. Five latent small tumors were newly detected using 5-ALA; all were carcinomas. Overall, five new tumors were detected by both ICG and 5-ALA fluorescence imaging; two were hepatocellular carcinomas (HCCs) and three were metastases of colorectal cancer. The sensitivity and specificity of ICG fluorescence imaging for main tumor detection were relatively high and low, respectively, but the opposite was true of 5-ALA imaging. Fluorescence imaging using 5-ALA may provide greater specificity in the detection of surface-invisible malignant liver tumors than using ICG fluorescence imaging alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  11. Recent advances in near-infrared fluorescence-guided imaging surgery using indocyanine green.

    Science.gov (United States)

    Namikawa, Tsutomu; Sato, Takayuki; Hanazaki, Kazuhiro

    2015-12-01

    Near-infrared (NIR) fluorescence imaging has better tissue penetration, allowing for the effective rejection of excitation light and detection deep inside organs. Indocyanine green (ICG) generates NIR fluorescence after illumination by an NIR ray, enabling real-time intraoperative visualization of superficial lymphatic channels and vessels transcutaneously. The HyperEye Medical System (HEMS) can simultaneously detect NIR rays under room light to provide color imaging, which enables visualization under bright light. Thus, NIR fluorescence imaging using ICG can provide for excellent diagnostic accuracy in detecting sentinel lymph nodes in cancer and microvascular circulation in various ischemic diseases, to assist us with intraoperative decision making. Including HEMS in this system could further improve the sentinel lymph node mapping and intraoperative identification of blood supply in reconstructive organs and ischemic diseases, making it more attractive than conventional imaging. Moreover, the development of new laparoscopic imaging systems equipped with NIR will allow fluorescence-guided surgery in a minimally invasive setting. Future directions, including the conjugation of NIR fluorophores to target specific cancer markers might be realistic technology with diagnostic and therapeutic benefits.

  12. Application of indocyanine green video angiography in surgical treatment of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2015-07-01

    Full Text Available Indocyanine green (ICG video angiography has been used for several medical indications in the last decades. It allows a real time evaluation of vascular structures during the surgery. This study describes the surgical results of a senior vascular neurosurgeon. We retrospectively searched our database for all aneurysm cases treated with the aid of intraoperative ICG from 2009 to 2014. A total of 61 aneurysms in 56 patients were surgically clipped using intraoperative ICG. Clip reposition after ICG happened in 2 patients (3.2%. Generally, highly variable clip adjustment rates of 2%–38% following ICG have been reported since the introduction of this imaging technique. The application of ICG in vascular neurosurgery is still an emerging challenge. It is an adjunctive strategy which facilitates aneurismal evaluation and treatment in experienced hands. Nevertheless, a qualified vascular neurosurgeon is still the most important component of a high quality work.

  13. Retinal pigment epithelial atrophy following indocyanine green dye-assisted surgery for serous macular detachment

    Directory of Open Access Journals (Sweden)

    Hussain Nazimul

    2008-01-01

    Full Text Available To report subretinal migration of indocyanine green dye (ICG and subsequent retinal pigment epithelial (RPE atrophy during macular surgery for serous macular detachment. A 65-year-old woman presented with residual epiretinal membrane and serous detachment of the macula following vitreoretinal surgery for epiretinal membrane. She underwent resurgery with ICG-assisted internal limiting membrane peeling and intraocular tamponade. Intraoperatively a large area of subretinal ICG was seen with subsequent RPE mottling and atrophy of the macula in the area involved during follow-up. This case demonstrates that subretinal migration of ICG is possible and can be toxic to RPE.

  14. Application of indocyanine green-fluorescence imaging to full-thickness cholecystectomy.

    Science.gov (United States)

    Morita, Kiyomi; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Shimizu, Atsushi; Yamamoto, Satoshi; Takemura, Nobuyuki; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-05-01

    Fluorescence imaging using indocyanine green (ICG) has recently been applied to laparoscopic surgery to identify cancerous tissues, lymph nodes, and vascular anatomy. Here we report the application of ICG-fluorescence imaging to visualize the boundary between the liver and subserosal tissues of the gallbladder during laparoscopic full-thickness cholecystectomy. A patient with a potentially malignant gallbladder lesion was administered 2.5-mg intravenous ICG just before laparoscopic full-thickness cholecystectomy. Intraoperative fluorescence imaging enabled the real-time delineation of both extrahepatic bile duct anatomy and hepatic parenchyma throughout the procedure, which resulted in complete removal of subserosal tissues between liver and gallbladder. Safe and feasible ICG-fluorescence imaging can be widely applied to laparoscopic hepatobiliary surgery by utilizing a biliary excretion property of ICG. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  15. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  16. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  17. Indocyanine green enhanced surgery; principle, clinical applications and future research directions

    Directory of Open Access Journals (Sweden)

    Catalin Alius

    2018-05-01

    Full Text Available Over the past decade a new emergent technology has become very popular in all fields of surgery using Indocyanine green and near infrared fluorescent optical systems. This revolutionary approach overlaps conventional and near infrared images to produce highly informative intraoperative images on the anatomy and physiology of various tissues. Near infrared fluorescence is employed for perioperative angiography in vascular mapping, assessment of anastomoses, location of sentinel lymph nodes and delineation of biliary tree anatomy, highlighting tumours and metastatic deposits, improving surgical techniques and for many other uses. A lot of researchers have reported better surgical outcomes and technique innovations facilitated by this novel technology which although in its early stages, it lights up great interest worldwide. This article reviews the principle of the method, the properties of the fluorescent dye, the main clinical applications and discusses future research directions.

  18. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy.

    Science.gov (United States)

    Kitagawa, Hiroyuki; Namikawa, Tsutomu; Iwabu, Jun; Hanazaki, Kazuhiro

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric tube. When pulling up the gastric tube through the post-mediastinum route, a root of the right gastroepiploic vein was injured. We subsequently performed superdrainage to avoid congestion of the gastric tube with omental vein and pre-tracheal vein anastomosis at the neck, and confirmed venous flow using the indocyanine green fluorescence method. No postoperative anastomotic leakage was observed, and the patient was discharged 22 days after surgery. Thus, we recommend the indocyanine green fluorescence method in cases involving superdrainage during esophagectomy. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  20. Phototoxic effect of conjugates of plasmon-resonance nanoparticles with indocyanine green dye on Staphylococcus aureus induced by IR laser radiation

    International Nuclear Information System (INIS)

    Tuchina, E S; Tuchin, Valerii V; Khlebtsov, B N; Khlebtsov, Nikolai G

    2011-01-01

    The effect of IR laser radiation (λ = 805 - 808 nm) on the bacteria of the strain Staphylococcus aureus 209 P, incubated in indocyanine green solutions, is studied, as well as that of colloid gold nanoshells, nanocages and their conjugates with indocyanine green. It is found that the S. aureus 209 P cells are equally subjected to the IR laser radiation (λ = 805 nm) after preliminary sensitisation with indocyanine green and gold nanoparticles separately and with conjugates of nanoparticles and indocyanine green. The enhancement of photodynamic and photothermal effects by 5 % is observed after 30 min of laser illumination (λ = 808 nm) of bacteria, treated with conjugates of indocyanine green and nanocages. (optical technologies in biophysics and medicine)

  1. Intra-Operative Indocyanine Green-Videoangiography (ICG-VA) in ...

    African Journals Online (AJOL)

    Methods: Fifteen consecutive patients with anterior circulation aneurysms who underwent craniotomy and clipping of the aneurysms were included in this study. Intraoperative ICG-VA was performed in all cases after exposure of the aneurysm and the branches in the vicinity of the aneurysm or the parent vessel before ...

  2. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  3. Comparison of indocyanine green clearance with Child's-Pugh score and hepatic histology: a multivariate analysis.

    Science.gov (United States)

    Mukherjee, Sandeep; Rogers, Mary A M; Buniak, Borys

    2006-01-01

    Indocyanine green clearance, measured by percentage disappearance rate, detects alterations in liver function and may be used as a non-invasive determinant of hepatic reserve. The aims of this study were to compare liver histology and Child's-Pugh score with percentage disappearance rate and determine which variables correlated with PDR. Child's-Pugh score, liver function tests, liver biopsies and indocyanine green testing (0.5mg/kg) were performed in 102 consecutive patients with cirrhosis of diverse etiologies. Indocyanine green concentration was determined using spectrophotometric analysis (806nm) and plotted logarithmically with Michaelis-Menten kinetics to calculate the percentage disappearance rate. Liver biopsies were graded using the modified Knodell score to obtain a histological activity index. In bivariable analysis, percentage disappearance rate significantly correlated with Child's-Pugh score, albumin, bilirubin, prothrombin time and histological activity index. Albumin, prothrombin time and histological activity index were independent predictors of percentage disappearance rate in the final model (albumin ptime ptime and histological activity index.

  4. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  5. A Review of Indocyanine Green Fluorescent Imaging in Surgery

    Directory of Open Access Journals (Sweden)

    Jarmo T. Alander

    2012-01-01

    Full Text Available The purpose of this paper is to give an overview of the recent surgical intraoperational applications of indocyanine green fluorescence imaging methods, the basics of the technology, and instrumentation used. Well over 200 papers describing this technique in clinical setting are reviewed. In addition to the surgical applications, other recent medical applications of ICG are briefly examined.

  6. Liver volume, portal vein flow, and clearance of indocyanine green and antipyrine in hyperthyroidism before and after antithyroid treatment

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Court-Payen, M

    1999-01-01

    The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment.......The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment....

  7. Targeted imaging of ovarian cancer cells using viral nanoparticles doped with indocyanine green

    Science.gov (United States)

    Guerrero, Yadir; Bahmani, Baharak; Jung, Bonsu; Vullev, Valentine; Kundra, Vikas; Anvari, Bahman

    2013-03-01

    Our group has constructed a new type of viral nanoparticles (VNPs) from genome-depleted plant infecting brome mosaic virus (BMV) that encapsulates the FDA-approved near infrared (NIR) indocyanine green (ICG)[1]. We refer to these VNPs as optical viral ghosts (OVGs) since the constructs lack the genomic content of wild-type BMV. One of our areas of interest is the application of OVGs for real-time intraoperative NIR fluorescence imaging of small peritoneal ovarian tumor nodules. We target human epidermal growth factor receptor-2 (HER-2) expression in ovarian cancer as a biomarker associated with ovarian cancer, since its over-expression is linked to the disease's progression to death. We functionalize the OVGs with anti-HER-2 monoclonal antibodies using reductive amination methods. We used fluorescence imaging to visualize the SKOV-3 cells (high HER-2 expression) after incubation with free ICG, OVGs, and functionalized OVGs. Our results suggest the possibility of using anti-HER2 conjugated OVGs in conjunction with cytoreductive surgery to detect small tumor nodules (<5cm) which currently are not excised during surgery.

  8. Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma.

    Science.gov (United States)

    Ishizawa, Takeaki; Masuda, Koichi; Urano, Yasuteru; Kawaguchi, Yoshikuni; Satou, Shouichi; Kaneko, Junichi; Hasegawa, Kiyoshi; Shibahara, Junji; Fukayama, Masashi; Tsuji, Shingo; Midorikawa, Yutaka; Aburatani, Hiroyuki; Kokudo, Norihiro

    2014-02-01

    Although clinical applications of intraoperative fluorescence imaging of liver cancer using indocyanine green (ICG) have begun, the mechanistic background of ICG accumulation in the cancerous tissues remains unclear. In 170 patients with hepatocellular carcinoma cells (HCC), the liver surfaces and resected specimens were intraoperatively examined by using a near-infrared fluorescence imaging system after preoperative administration of ICG (0.5 mg/kg i.v.). Microscopic examinations, gene expression profile analysis, and immunohistochemical staining were performed for HCCs, which showed ICG fluorescence in the cancerous tissues (cancerous-type fluorescence), and HCCs showed fluorescence only in the surrounding non-cancerous liver parenchyma (rim-type fluorescence). ICG fluorescence imaging enabled identification of 273 of 276 (99%) HCCs in the resected specimens. HCCs showed that cancerous-type fluorescence was associated with higher cancer cell differentiation as compared with rim-type HCCs (P Fluorescence microscopy identified the presence of ICG in the canalicular side of the cancer cell cytoplasm, and pseudoglands of the HCCs showed a cancerous-type fluorescence pattern. The ratio of the gene and protein expression levels in the cancerous to non-cancerous tissues for Na(+)/taurocholate cotransporting polypeptide (NTCP) and organic anion-transporting polypeptide 8 (OATP8), which are associated with portal uptake of ICG by hepatocytes that tended to be higher in the HCCs that showed cancerous-type fluorescence than in those that showed rim-type fluorescence. Preserved portal uptake of ICG in differentiated HCC cells by NTCP and OATP8 with concomitant biliary excretion disorders causes accumulation of ICG in the cancerous tissues after preoperative intravenous administration. This enables highly sensitive identification of HCC by intraoperative ICG fluorescence imaging.

  9. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    Directory of Open Access Journals (Sweden)

    Wilson Michael

    2008-07-01

    Full Text Available Abstract Background The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs. Light of an appropriate wavelength activates the LAAA to produce cytotoxic species which can then cause bacterial cell death via loss of membrane integrity, lipid peroxidation, the inactivation of essential enzymes, and/or exertion of mutagenic effects due to DNA modification. In this study, the effect of the LAAA indocyanine green excited with high or low intensity light (808 nm from a near-infrared laser (NIR on the viability of Staphylococcus aureus, Streptococcus pyogenes and Pseudomonas aeruginosa was investigated. Results All species were susceptible to killing by the LAAA, the bactericidal effect being dependent on both the concentration of indocyanine green and the light dose. Indocyanine green photosensitization using both high (1.37 W cm-2 and low (0.048 W cm-2 intensity NIR laser light was able to achieve reductions of 5.6 log10 (>99.99% and 6.8 log10 (>99.99% in the viable counts of Staph. aureus and Strep. pyogenes (using starting concentrations of 106–107 CFU ml-1. Kills of 99.99% were obtained for P. aeruginosa (initial concentration 108–109 CFU ml-1 photosensitized by the high intensity light (1.37 W cm-2; while a kill of 80% was achieved using low intensity irradiation (0.07 W cm-2. The effects of L-tryptophan (a singlet oxygen scavenger and deuterium oxide (as an enhancer of the life span of singlet oxygen on the survival of Staph. aureus was also studied. L-tryptophan reduced the proportion of Staph. aureus killed; whereas deuterium oxide increased the proportion killed suggesting that singlet oxygen was involved in the killing of the bacteria. Conclusion These findings imply that indocyanine green in combination with light from a near-infrared laser may be an effective means of eradicating bacteria

  10. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  11. Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy.

    Science.gov (United States)

    Kudo, Hiroki; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Ichida, Akihiko; Shimizu, Atsushi; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-08-01

    Although laparoscopic hepatectomy has increasingly been used to treat cancers in the liver, the accuracy of intraoperative diagnosis may be inferior to that of open surgery because the ability to visualize and palpate the liver surface during laparoscopy is relatively limited. Fluorescence imaging has the potential to provide a simple compensatory diagnostic tool for identification of cancers in the liver during laparoscopic hepatectomy. In 17 patients who were to undergo laparoscopic hepatectomy, 0.5 mg/kg body weight of indocyanine green (ICG) was administered intravenously within the 2 weeks prior to surgery. Intraoperatively, a laparoscopic fluorescence imaging system obtained fluorescence images of its surfaces during mobilization of the liver. In all, 16 hepatocellular carcinomas (HCCs) and 16 liver metastases (LMs) were resected. Of these, laparoscopic ICG fluorescence imaging identified 12 HCCs (75%) and 11 LMs (69%) on the liver surfaces distributed over Couinaud's segments 1-8, including the 17 tumors that had not been identified by visual inspections of normal color images. The 23 tumors that were identified by fluorescence imaging were located closer to the liver surfaces than another nine tumors that were not identified by fluorescence imaging (median [range] depth 1 [0-5] vs. 11 [8-30] mm; p fluorescence imaging enables real-time identification of subcapsular liver cancers, thus facilitating estimation of the required extent of hepatic mobilization and determination of the location of an appropriate hepatic transection line.

  12. Model and methods to assess hepatic function from indocyanine green fluorescence dynamical measurements of liver tissue.

    Science.gov (United States)

    Audebert, Chloe; Vignon-Clementel, Irene E

    2018-03-30

    The indocyanine green (ICG) clearance, presented as plasma disappearance rate is, presently, a reliable method to estimate the hepatic "function". However, this technique is not instantaneously available and thus cannot been used intra-operatively (during liver surgery). Near-infrared spectroscopy enables to assess hepatic ICG concentration over time in the liver tissue. This article proposes to extract more information from the liver intensity dynamics by interpreting it through a dedicated pharmacokinetics model. In order to account for the different exchanges between the liver tissues, the proposed model includes three compartments for the liver model (sinusoids, hepatocytes and bile canaliculi). The model output dependency to parameters is studied with sensitivity analysis and solving an inverse problem on synthetic data. The estimation of model parameters is then performed with in-vivo measurements in rabbits (El-Desoky et al. 1999). Parameters for different liver states are estimated, and their link with liver function is investigated. A non-linear (Michaelis-Menten type) excretion rate from the hepatocytes to the bile canaliculi was necessary to reproduce the measurements for different liver conditions. In case of bile duct ligation, the model suggests that this rate is reduced, and that the ICG is stored in the hepatocytes. Moreover, the level of ICG remains high in the blood following the ligation of the bile duct. The percentage of retention of indocyanine green in blood, which is a common test for hepatic function estimation, is also investigated with the model. The impact of bile duct ligation and reduced liver inflow on the percentage of ICG retention in blood is studied. The estimation of the pharmacokinetics model parameters may lead to an evaluation of different liver functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    Science.gov (United States)

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  14. Effects of indocyanine green videoangiography and electrophysiological monitoring on surgery for intracranial aneurysms

    International Nuclear Information System (INIS)

    Arai, Yoshikazu; Kitai, Ryuhei; Awara, Kosuke

    2011-01-01

    We analyzed the outcome of 62 consecutive patients with unruptured intracranial aneurysm treated by surgical clipping. Thirty-one cases were operated without intraoperative monitoring, 17 cases with indocyanine green videoangiography (ICGA), and 14 cases with electrophysiological monitoring (EPM) in addition to ICGA. Complete obliteration of the aneurysm was confirmed in all 62 cases. Diffusion-weighted imaging of MRI disclosed no ischemic lesions after surgery in any of the cases. Asymptomatic venous infarction was detected by CT study in 2 cases. Cranial nerve palsy occurred in 4 cases but EPM could not detect it. There was no difference among the group without monitoring, the group with ICGA and the group with ICGA and EPM. The mortality and morbidity of all cases was calculated as 0% and 6.5%, respectively. ICGA appeared to be useful in surgery for aneurysms encasing perforators or for repair of problems such as premature rupture. eicosapentaenoic acid (EPA) seemed effective in surgery for anterior choroidal artery aneurysms or aneurysms requiring trapping before clipping. However, monitoring would not have been effective without extensive dissection of aneurysms, suggesting that basic microsurgical techniques are crucial for successful surgery. (author)

  15. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy

    OpenAIRE

    KITAGAWA, HIROYUKI; NAMIKAWA, TSUTOMU; IWABU, JUN; HANAZAKI, KAZUHIRO

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric t...

  16. Antipyrine, oxazepam, and indocyanine green clearance in patients with chronic pancreatitis and healthy subjects

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Larsen, S

    1999-01-01

    Hepatic drug metabolism was examined in patients with chronic pancreatitis and healthy controls by using a cocktail design with three different model compounds: antipyrine to express phase-I oxidation, oxazepam to express phase-II conjugation, and indocyanine green (ICG), a high-clearance compound....

  17. Microencapsulation of indocyanine green for potential applications in image-guided drug delivery.

    Science.gov (United States)

    Zhu, Zhiqiang; Si, Ting; Xu, Ronald X

    2015-02-07

    We present a novel process to encapsulate indocyanine green (ICG) in liposomal droplets at high concentration for potential applications in image-guided drug delivery. The microencapsulation process follows two consecutive steps of droplet formation by liquid-driven coaxial flow focusing (LDCFF) and solvent removal by oil phase dewetting. These biocompatible lipid vesicles may have important applications in drug delivery and fluorescence imaging.

  18. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  19. Indocyanine Green Videoangiography for Surgery of a Ruptured Dissecting Aneurysm in the Precommunicating Anterior Cerebral Artery: A Technical Case Report.

    Science.gov (United States)

    Nagai, Yasunori; Goto, Masanori; Toda, Hiroki; Nishida, Namiko; Yoshimoto, Naoya; Iwasaki, Koichi

    2017-08-01

    Indocyanine green videoangiography (ICG-VA) is an important intraoperative adjunct for saccular aneurysm surgery, but its efficacy in surgery for dissecting aneurysms has rarely been reported. The authors describe the usefulness of preclipping ICG-VA in a rare case of a ruptured dissecting aneurysm located at the precommunicating (A1) segment of the anterior cerebral artery. A 52-year-old woman, with no history of connective tissue diseases or vascular disorders, presented with sudden headache and convulsion. The CT scan showed that the patient had subarachnoid hemorrhage. Angiography showed a dissecting aneurysm in the left A1 segment of the anterior cerebral artery. Thus, the patient underwent trapping of the dissecting aneurysm. ICG-VA was used as an intraoperative adjunct before and after clipping. The preclipping ICG-VA showed the heterogeneously bright dissecting aneurysm and branching arteries even in the presence of hematoma. Preclipping ICG-VA may enhance the advantage of direct surgery for dissecting aneurysm by allowing visualization of the extent of the dissected vascular wall and the related branching arteries. ICG-VA can be an indispensable adjunct to minimize the compromise from the surgical treatment for intracranial dissecting aneurysms. Copyright © 2017 by the Congress of Neurological Surgeons

  20. Application of Indocyanine Green in Flap Surgery: A Systematic Review.

    Science.gov (United States)

    Li, Ke; Zhang, Zheng; Nicoli, Fabio; D'Ambrosia, Christopher; Xi, Wenjing; Lazzeri, Davide; Feng, Shaoqing; Su, Weijie; Li, Hua; Ciudad, Pedro; Tremp, Mathias; Zhang, Yi Xin

    2018-02-01

     The vascularization of the distal portions of transferred tissue represents the most critical factor in the success of reconstructive surgery. In recent years, indocyanine green (ICG) fluorescence imaging techniques have been applied during surgery to evaluate flap perfusion. However, this investigation has found that there is little consensus regarding the standard dose of ICG as well as the pre-operative requirements of ICG allergy testing. The aim of this study is to summarize the applications of ICG to tissue transfers and safe dosing practices and to provide insight to the possible adverse effects of ICG on flap surgery with the goal of helping clinicians apply ICG safely and efficiently to tissue transfer procedures.  A literature search was performed using, Wiley InterScience, and Springer with the key words, 'Flap,' 'indocyanine green,' 'surgery,' and related mesh words for all publications between 2005 and 2015. Title and abstract screening was performed using predefined in- and exclusion criteria.  Seventy-three articles were included. These were classified as "application of ICG in flap surgery" and "the security of applying ICG in flap surgery".  ICG fluorescence imaging preoperatively facilitates the detection of perforators in tissue flaps with thickness <20 mm, aids in the evaluation of flap microcirculation and perfusion, and allows surgeons to select dominant cutaneous nerves while evaluating the quality of vascular anastomoses and locating thromboses. The literature also concluded that potential allergic reactions to ICG should be taken into consideration. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    DEFF Research Database (Denmark)

    Omar, Ghada Said Mohammed; Wilson, Michael; Nair, Sean P.

    2008-01-01

    Background: The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs). Light of an appropriate wavelength activates the LAAA to produce cytotoxic...... of the bacteria. Conclusion: These findings imply that indocyanine green in combination with light from a nearinfrared laser may be an effective means of eradicating bacteria from wounds and burns....

  2. Dynamic indocyanine green angiography measurements

    Science.gov (United States)

    Holmes, Timothy; Invernizzi, Alessandro; Larkin, Sean; Staurenghi, Giovanni

    2012-11-01

    Dynamic indocyanine green imaging uses a scanning laser ophthalmoscope and a fluorescent dye to produce movies of the dye-filling pattern in the retina and choroid of the eye. It is used for evaluating choroidal neovascularization. Movies are examined to identify the anatomy of the pathology for planning treatment and to evaluate progression or response to treatment. The popularity of this approach is affected by the complexity and difficulty in interpreting the movies. Software algorithms were developed to produce images from the movies that are easy to interpret. A mathematical model is formulated of the flow dynamics, and a fitting algorithm is designed that solves for the flow parameters. The images provide information about flow and perfusion, including regions of change between examinations. Imaged measures include the dye fill-time, temporal dispersion, and magnitude of the dye dilution temporal curves associated with image pixels. Cases show how the software can help to identify clinically relevant anatomy such as feeder vessels, drain vessels, capillary networks, and normal choroidal draining vessels. As a potential tool for research into the character of neovascular conditions and treatments, it reveals the flow dynamics and character of the lesion. Future varieties of this methodology may be used for evaluating the success of engineered tissue transplants, surgical flaps, reconstructive surgery, breast surgery, and many other surgical applications where flow, perfusion, and vascularity of tissue are important.

  3. Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    Science.gov (United States)

    Rathmann, P; Chalopin, C; Halama, D; Giri, P; Meixensberger, J; Lindner, D

    2018-03-01

    Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermography (DIRT) is a promising alternative modality that was evaluated by comparison with ICGA. The study was carried out in two parts: (1) investigation of technical conditions for intraoperative use of DIRT for its comparison with ICGA, and (2) visual and quantitative comparison of both modalities in a proof of concept on nine patients. Time-temperature curves in DIRT and time-intensity curves in ICGA for defined regions of interest were analyzed. New perfusion parameters were defined in DIRT and compared with the usual perfusion parameters in ICGA. The visual observation of the image data in DIRT and ICGA showed that operation material, anatomical structures and skin perfusion are represented similarly in both modalities. Although the analysis of the curves and perfusion parameter values showed differences between patients, no complications were observed clinically. These differences were represented in DIRT and ICGA equivalently. DIRT has shown a great potential for intraoperative use, with several advantages over ICGA. The technique is passive, contactless and noninvasive. The practicability of the intraoperative recording of the same operation field section with ICGA and DIRT has been demonstrated. The promising results of this proof of concept provide a basis for a trial with a larger number of patients.

  4. Comparison of indocyanine green fluorescence and parathyroid autofluorescence imaging in the identification of parathyroid glands during thyroidectomy.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-12-01

    Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P0.99]. To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF.

  5. [Sentinel node detection using optonuclear probe (gamma and fluorescence) after green indocyanine and radio-isotope injections].

    Science.gov (United States)

    Poumellec, M-A; Dejode, M; Figl, A; Darcourt, J; Haudebourg, J; Sabah, Y; Voury, A; Martaens, A; Barranger, E

    2016-04-01

    Assess the biopsy's feasibility of the sentinel lymph node biopsy (SLNB) using optonuclear probe after of indocyanine green (ICG) and radio-isotope (RI) injections. Twenty-one patients with a localized breast cancer and unsuspicious axillary nodes underwent a SLNB after both injections of ICG and radio-isotope. One or more SLN were identified on the 21 patients (identification rate of 100%). The median number SLN was 2 (1-3). Twenty SLN were both radio-actives and fluorescents (54.1%), 11 fluorescent only (29.7%) and 6 were only radio-actives (16.2%). Seven patients had a metastatic SLN (8 SLN overall). Among them, only one had a micrometastasic SLN, 5 others had a macrometastatic SLN and one patient had two macrometastatic SLNs. Among the 8 metastatic SLN, 5 were both fluorescent and radioactive, 2 were only fluorescent and 1 was only radioactive. Detection SLN using optonuclear probe after indocyanine green and radio-isotope injections is effective and could be, after validation by randomized trial, a reliable alternative to the blue dye injection for teams who consider that combined detection as the reference. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  7. Indocyanine Green Videoangiography in Negative: Spinal Dural Arteriovenous Fistula.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Sanromán Álvarez, Pablo; Pérez de San Román, Laila; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2015-08-01

    Introduction This work reports the first indocyanine green videoangiography (IGV) in negative published with video format support. This technique, so called because its first phase is performed with occlusion of the vessel suspected of being pathologic, is used for the diagnosis of spinal arteriovenous fistula (sDAVF). Case Report The authors present the case of a 68-year-old man with an sDAVF fed by the right T7 segmentary artery. IGV was initially performed with the presumptive fistula feeder occluded for less than 1 minute, which provided both diagnostic and postexclusion control in one procedure. This technique therefore is reversible by not prolonging vascular exclusion times. Discussion IGV in negative is an extremely visual and intuitive procedure that represents an improvement over conventional IGV. Conclusion Studies with larger sample sizes are necessary to determine whether IGV in negative can further reduce the need for postoperative digital subtraction angiography.

  8. Multiphoton photodegradation of indocyanine green: Solvent protolysis effect

    Energy Technology Data Exchange (ETDEWEB)

    Fuyuki, Masanori, E-mail: mn.fuyuki@kio.ac.jp

    2016-02-15

    The multiphoton photodegradation mechanism of indocyanine green (ICG) was investigated by using femtosecond near-infrared (NIR) pump and probe pulses. In the pump fluence region from 2 mJ/cm{sup 2} to 4 mJ/cm{sup 2}, the photodegradation rate was higher in acetic acid than in ethanol, and the rate was proportional to pump fluence to the 2.3th power in acetic acid and the 3.9th in ethanol. Considering that the degree of auto-protolysis of acetic acid is much higher than that of ethanol, the experimental results indicate that self-ionized solvent molecules played an essential role in the degradation of ICG molecules excited by NIR multiphoton process. - Highlights: • Photodegradation of ICG by femtosecond near-infrared pulses. • Photodegradation rate of ICG was higher in acetic acid than in ethanol. • Photodegradation rate was proportional to pump fluence to 2.3th power in acetic acid. • Photodegradation rate was proportional to pump fluence to 3.9th power in ethanol. • Self-ionized solvent molecules promoted ICG photodegradation in acetic acid.

  9. Indocyanine green videoangiography "in negative": definition and usefulness in spinal dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; López González, Antonio; Evangelista Zamora, Rocío; Botella Asunción, Carlos

    2013-05-01

    Indocyanine green videoangiography (IGV) has proven its effectiveness in the field of exovascular neurosurgery, both in the intracranial and spinal compartment, but is necessary to define a systematic process for the performance of the IGV to facilitate its interpretation during the procedure. We have defined and applied the concept of videoangiography "in negative" (INIGV) to spinal dural arteriovenous fistulae (dAVF) for the detection and treatment of arteriovenous shunts, so called because the first phase is performed with the vessel suggestive of being pathological occluded. A Pentero-operating microscope with near-infrared IGV-integrated system (Carl Zeiss Co., Germany) was used. At our institution, 24 patients were treated for a spinal dAVF between 1995 and 2011, only in the last 4 cases, INIGV was performed. We describe the IGV in negative procedure and show the most illustrative cases. In all cases, the fistula occlusion was confirmed by postoperative selective digital subtraction angiography (DSA). INIGV demonstrate its capacity in detecting vessels not actually arterialized that should be respected and avoid some of the main limitations of the conventional IGV. This is a technical description about an Indocyanine green (ICG) videoangiographic procedure modification that is superior to merely performing ICG before and after clipping of a dAVF. The INIGV results are rapid and easy to interpret procedure and provide great advantages to the dAVF treatment. Nevertheless, further studies are needed with a larger sample size to determine if INIGV may reduce the need to perform immediate postoperative DSA.

  10. [Indocyanine green angiography in "multiple evanescent white dot syndrome" (MEWDS)].

    Science.gov (United States)

    Desarnaulds, A B; Borruat, F X; Herbort, C P; de Courten, C

    1998-05-01

    Multiple evanescent white dot syndrome (MEWDS) is a benign acquired chorioretinal disorder occurring mostly in young adults. Its pathophysiology is unknown. To describe the results of indocyanine green angiography (ICGA) in MEWDS. Four patients with MEWDS were investigated by ICGA. In all cases, ICGA revealed numerous choroidal hypofluorescent lesions that largely outnumbered the lesions visible with either fundoscopy or fluorescein angiography. Three cases showed a blind spot enlargement on perimetry associated with the presence of a large peripapillary hypofluorescent zone on ICGA. Three cases showed macular granularity on fundoscopy correlating with a significant subfoveal hypfluorescent lesion on ICGA. Evolution was always favorable with disappearance of the hypofluorescent choroidal lesions. Our results confirm that MEWDS is primarily a choroidal disorder. The blind spot enlargement and the macular granularity, frequently detected in MEWDS, result from larger peripapillary and subfoveal choroidal lesions.

  11. In Vitro Efficacy and Mechanistic Role of Indocyanine Green as a Photodynamic Therapy Agent for Human Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.; Gamal-Eldeen, A; Ruppel, M; Smith, R; Tsang, T; Miller, L

    2009-01-01

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway.

  12. Laparoscopic Sentinel Node Mapping in Endometrial Cancer After Hysteroscopic Injection of Indocyanine Green.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-01-01

    To report the detection rate (DR) of sentinel lymph nodes (SLNs) in endometrial cancer (EC) patients after hysteroscopic injection of indocyanine green (ICG) and laparoscopic near-infrared (L-NIR) fluorescence mapping. Prospectively collected data (Canadian Task Force classification II-2). Gynecologic oncology referral center. Consecutive patients with apparent early-stage endometrioid EC scheduled for surgical treatment: total laparoscopic hysterectomy, bilateral salpingo-oophorectomy, SLN mapping. The mapping technique consisted in an intraoperative hysteroscopic peritumoral injection of 5 mg ICG followed by L-NIR fluorescence mapping. Evaluations of the SLN DR and sites of mapping were performed. A total of 57 procedures was performed. Patient mean age was 60 years (range, 28-80) and mean body mass index was 28.2 kg/m 2 (range, 19-43). At least 1 SLN was detected in 89.5% of the whole population (51/57). After the first 16 cases, L-NIR camera technical improvement led to a 95% DR (39/41). The mean number of harvested SLNs was 4.1 (range. 1-8), and in 47% of cases SLNs mapped to aortic nodes (24/51). Bilateral pelvic mapping was found in 74.5% of cases (38/51). Three patients had SLN metastases: 1 in the pelvic area only, 1 both in the pelvic and aortic area, and 1 presented with 2 metastatic aortic SLNs with negative pelvic SLNs. Overall, 2 of 3 node-positive patients (67%) had aortic SLN involvement. No adverse events were reported. Laparoscopic SLN mapping after the hysteroscopic injection of ICG has comparable DRs with both radioactive tracer series and ICG series with cervical injection, overcoming the need for radioactive substances. Hysteroscopic injection leads to a higher mapping in the aortic area compared with cervical injection. Further investigation is warranted on this topic. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Hepatic blood flow determination. A comparison of 99mTc-diethyl-IDA and indocyanine green as hepatic blood flow indicators in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Winkler, K

    1987-01-01

    99mTc-diethyl-acetanilide-iminodiacetic acid (IDA) was compared with indocyanine green (ICG) as an indicator of hepatic blood flow (HBF). Twelve subjects (8 with cirrhosis, 2 with fatty liver, one with pancreatitis, and one with intestinal angina) were studied during hepatic vein catheterization...

  14. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    Science.gov (United States)

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye

  15. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  16. The use of indocyanine green lymphography for the treatment of postoperative chylothorax with lipiodol lymphangiography in a 2-year-old child

    Directory of Open Access Journals (Sweden)

    Motoi Kato

    2017-08-01

    Full Text Available Postoperative chylothorax in infants prolongs hospital stay and possibly causes developmental delay because of its conservative treatment including inanition. Several medical and surgical treatments may be applied, but none constitute the absolute solution. Treatment with lipiodol during lymphangiography for postoperative chylothorax has been reported to be highly effective and less invasive in adults. On the other hand, few cases have been reported in infants. We demonstrate successful blockage of chyle leakage with lipiodol injection through the inguinal lymph node in a 2-year-old infant. The patient had undergone on-pump coarctectomy and chylothorax developed soon after surgery. Several medical treatments were partially effective, but the chest tube could not be removed because sequential aspiration was required to maintain a normal respiratory status. With the patient under general anesthesia, lipiodol injection combined with indocyanine green (ICG lymphography was performed. Lymphography combined with ICG significantly contributed not only to intraoperative detection of the inguinal lymph nodes but also to postoperative early detection of lymphedema caused by this procedure. This procedure required a simple maneuver and is probably applicable to other cases of traumatic chylothorax, such as after surgeries on the esophagus, trachea, or other components of the posterior mediastinum.

  17. Two Cases of Severe Degeneration of the Macula Following Vitrectomy with Indocyanine Green-Assisted Internal Limiting Membrane Peeling for Idiopathic Macular Hole

    OpenAIRE

    Inoue, Junji; Sakuma, Toshiro; Kiyokawa, Masatoshi; Kobayashi, Yasuhiko; Takebayashi, Hiroshi; Mizota, Atsushi; Tanaka, Minoru

    2008-01-01

    We describe three eyes of two cases of severe degeneration of the macula following vitrectomy with indocyanine green-assisted internal limiting membrane peeling for idiopathic macular hole. We need to remember the possibility of these complications and have to select the procedures that are safest to use for macular hole surgery.

  18. Near-infrared fluorescence cholangiography with indocyanine green for biliary atresia. Real-time imaging during the Kasai procedure: a pilot study.

    Science.gov (United States)

    Hirayama, Yutaka; Iinuma, Yasushi; Yokoyama, Naoyuki; Otani, Tetsuya; Masui, Daisuke; Komatsuzaki, Naoko; Higashidate, Naruki; Tsuruhisa, Shiori; Iida, Hisataka; Nakaya, Kengo; Naito, Shinichi; Nitta, Koju; Yagi, Minoru

    2015-12-01

    Hepatoportoenterostomy (HPE) with the Kasai procedure is the treatment of choice for biliary atresia (BA) as the initial surgery. However, the appropriate level of dissection level of the fibrous cone (FC) of the porta hepatis (PH) is frequently unclear, and the procedure sometimes results in unsuccessful outcomes. Recently, indocyanine green near-infrared fluorescence imaging (ICG-FCG) has been developed as a form of real-time cholangiography. We applied this technique in five patients with BA to visualize the biliary flow at the PH intraoperatively. ICG was injected intravenously the day before surgery as the liver function test, and the liver was observed with a near-infrared camera system during the operation while the patient's feces was also observed. In all patients, the whole liver fluoresced diffusely with ICG-containing stagnant bile, whereas no extrahepatic structures fluoresced. The findings of the ICG fluorescence pattern of the PH after dissection of the FC were classified into three types: spotty fluorescence, one patient; diffuse weak fluorescence, three patients; and diffuse strong fluorescence, one patient. In all five patients, the feces evacuated after HPE showed distinct fluorescent spots, although that obtained before surgery showed no fluorescence. One patient with diffuse strong fluorescence who did not achieve JF underwent living related liver transplantation six months after the initial HPE procedure. Four patients, including three cases involving diffuse weak fluorescence and one case involving spotty fluorescence showed weak fluorescence compared to that of the surrounding liver surface. We were able to detect the presence of bile excretion at the time of HPE intraoperatively and successfully evaluated the extent of bile excretion using this new technique. Furthermore, the ICG-FCG findings may provide information leading to a new classification and potentially function as an indicator predicting the clinical outcomes after HPE.

  19. Development of ultrasound-assisted fluorescence imaging of indocyanine green.

    Science.gov (United States)

    Morikawa, Hiroyasu; Toyota, Shin; Wada, Kenji; Uchida-Kobayashi, Sawako; Kawada, Norifumi; Horinaka, Hiromichi

    2017-01-01

    Indocyanine green (ICG) accumulation in hepatocellular carcinoma means tumors can be located by fluorescence. However, because of light scattering, it is difficult to detect ICG fluorescence from outside the body. We propose a new fluorescence imaging method that detects changes in the intensity of ICG fluorescence by ultrasound-induced temperature changes. ICG fluorescence intensity decreases as the temperature rises. Therefore, it should theoretically be possible to detect tissue distribution of ICG using ultrasound to heat tissue, moving the point of ultrasound transmission, and monitoring changes in fluorescence intensity. A new probe was adapted for clinical application. It consisted of excitation light from a laser, fluorescence sensing through a light pipe, and heating by ultrasound. We applied the probe to bovine liver to image the accumulation of ICG. ICG emits fluorescence (820 nm) upon light irradiation (783 nm). With a rise in temperature, the fluorescence intensity of ICG decreased by 0.85 %/°C. The distribution of fluorescent ICG was detected using an ultrasonic warming method in a new integrated probe. Modulating fluorescence by changing the temperature using ultrasound can determine where ICG accumulates at a depth, highlighting its potential as a means to locate hepatocellular carcinoma.

  20. The Role of Indocyanine Green for Robotic Partial Nephrectomy: Early Results, Limitations and Future Directions

    Directory of Open Access Journals (Sweden)

    Zachary Klaassen

    2014-07-01

    Full Text Available The surgical management of small renal masses has continued to evolve, particularly with the advent of the robotic partial nephrectomy (RPN. Recent studies at high volume institutions utilizing near infrared imaging with indocyanine green (ICG fluorescent dye to delineate renal tumor anatomy has generated interest among robotic surgeons for improving warm ischemia times and positive margin rate for RPN. To date, early studies suggest positive margin rate using ICG is comparable to traditional RPN, however this technology improves visualization of the renal vasculature allowing selective clamping or zero ischemia. The precise combination of fluorescent compound, dose, and optimal tumor anatomy for ICG RPN has yet to be elucidated.

  1. In Vivo Photoacoustic and Fluorescence Cystography Using Clinically Relevant Dual Modal Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Sungjo Park

    2014-10-01

    Full Text Available Conventional X-ray-based cystography uses radio-opaque materials, but this method uses harmful ionizing radiation and is not sensitive. In this study, we demonstrate nonionizing and noninvasive photoacoustic (PA and fluorescence (FL cystography using clinically relevant indocyanine green (ICG in vivo. After transurethral injection of ICG into rats through a catheter, their bladders were photoacoustically and fluorescently visualized. A deeply positioned bladder below the skin surface (i.e., ~1.5–5 mm was clearly visible in the PA and FL image using a laser pulse energy of less than 2 mJ/cm2 (1/15 of the safety limit. Then, the in vivo imaging results were validated through in situ studies. Our results suggest that dual modal cystography can provide a nonionizing and noninvasive imaging tool for bladder mapping.

  2. Near-infrared intraoperative imaging during resection of an anterior mediastinal soft tissue sarcoma.

    Science.gov (United States)

    Predina, Jarrod D; Newton, Andrew D; Desphande, Charuhas; Singhal, Sunil

    2018-01-01

    Sarcomas are rare malignancies that are generally treated with multimodal therapy protocols incorporating complete local resection, chemotherapy and radiation. Unfortunately, even with this aggressive approach, local recurrences are common. Near-infrared intraoperative imaging is a novel technology that provides real-time visual feedback that can improve identification of disease during resection. The presented study describes utilization of a near-infrared agent (indocyanine green) during resection of an anterior mediastinal sarcoma. Real-time fluorescent feedback provided visual information that helped the surgeon during tumor localization, margin assessment and dissection from mediastinal structures. This rapidly evolving technology may prove useful in patients with primary sarcomas arising from other locations or with other mediastinal neoplasms.

  3. Indocyanine green labeled with 123I for dynamic studies of the hepato-biliary system

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub 1 / 2 / = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of 123 I-ICG (in dogs) will be compared to 131 I-rose bengal and bromosulphalein labeled with iodine-125

  4. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  5. Near-infrared-fluorescence imaging of lymph nodes by using liposomally formulated indocyanine green derivatives.

    Science.gov (United States)

    Toyota, Taro; Fujito, Hiromichi; Suganami, Akiko; Ouchi, Tomoki; Ooishi, Aki; Aoki, Akira; Onoue, Kazutaka; Muraki, Yutaka; Madono, Tomoyuki; Fujinami, Masanori; Tamura, Yutaka; Hayashi, Hideki

    2014-01-15

    Liposomally formulated indocyanine green (LP-ICG) has drawn much attention as a highly sensitive near-infrared (NIR)-fluorescence probe for tumors or lymph nodes in vivo. We synthesized ICG derivatives tagged with alkyl chains (ICG-Cn), and we examined NIR-fluorescence imaging for lymph nodes in the lower extremities of mice by using liposomally formulated ICG-Cn (LP-ICG-Cn) as well as conventional liposomally formulated ICG (LP-ICG) and ICG. Analysis with a noninvasive preclinical NIR-fluorescence imaging system revealed that LP-ICG-Cn accumulates in only the popliteal lymph node 1h after injection into the footpad, whereas LP-ICG and ICG accumulate in the popliteal lymph node and other organs like the liver. This result indicates that LP-ICG-Cn is a useful NIR-fluorescence probe for noninvasive in vivo bioimaging, especially for the sentinel lymph node. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  7. Photodynamic actions of indocyanine green and trypan blue on human lens epithelial cells in vitro.

    Science.gov (United States)

    Melendez, Robert F; Kumar, Neeru; Maswadi, Saher M; Zaslow, Kenneth; Glickmank, Randolph D

    2005-07-01

    The purpose of this study was to evaluate the toxicity and photodynamic activity of indocyanine green (ICG) and trypan blue (TryB) on cultured human lensepithelial cells (LECs). Experimental study. Lens epithelial cell viability was assessed after treatment with ICG and TryB concentrations ranging from 0.025 to 5.0 mg/ml, and exposure to 806 nm diode laser. At ICG concentrations below 0.5 mg/ml, there was > or =75% cell viability; at higher ICG concentrations there was dose-dependent cytotoxicity in addition to loss of cellular viability due to ICG photosensitization. TryB had little cytotoxicity to the LECs: >80% cells were viable irrespective of the dye concentration or laser treatment. These data indicate that ICG may have application as a photosensitizer in the selective eradication of residual LECs after cataract surgery to reduce the incidence of posterior capsule opacification.

  8. Symmetricity analysis of time to peak parameter of indocyanine green dynamics

    Science.gov (United States)

    An, Yuri; Lee, Jungsul; Choi, Chulhee

    2013-03-01

    We have previously discovered that near-infrared optical imaging of indocyanine green (ICG) signal and analyzing its dynamics can be applied for measurement of blood perfusion rate and detection of Raynaud's phenomenon (RP). Especially, RP is closely associated with abnormal vasomotor responses and can progress to tissue necrosis due to excessively sustained vasoconstriction. Therefore, early detecting of RP is one of important implication to prevent tissue damage from peripheral vascular disorders. In the present study, we propose new analysis and scoring method of symmetricity of Tmax value of left and right extremities. Moreover, this symmetricity analysis can give further information about microvascular insufficiency. For validation of the proposed method, we tested whether the segmental and paired analysis of Tmax value (time-to-peak) of ICG dynamics can be used for sensitive diagnosis of microvascular abnormalities which cannot be detected by conventional methods. From the near-infrared images of diabetes mellitus patients with vascular complications, the trend of asymmetry in Tmax value was observed. We assumed that decreasing local blood perfusion by autonomic nerve dysfunction causes the asymmetric Tmax value of right and left feet. These results collectively indicate that the proposed method can be used as a useful diagnostic tool for RP or other microvascular disorders.

  9. New technique for laryngotracheal mucosa transplantation. 'Stamp' welding using indocyanine green dye and albumin interaction with diode laser.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Gleich, L L; Rebeiz, E E; Shapshay, S M

    1995-07-01

    To investigate (1) the possibility of survival of free mucosa "stamp" grafts fixed in the airway with a new technique using indocyanine green-dyed albumin solder activated with a diode laser and (2) the degree of improvement of wound healing in the airway by applying modified microskin transplantation techniques from burn surgery to cover a relatively large wound with a few small pieces of mucosa anchored in place with the previously mentioned technique. Three (one control and two experimental) rectangular (10 x 8 mm) wounds in tracheal mucosa were produced in four experimental animals (dogs) using a carbon dioxide laser. The control wound was left uncovered. In the first experimental wound, a mucosal flap was raised and then fixed in place by a trapdoor flap method. In the second experimental wound, two small (each 2 x 3 mm) autogenous mucosa grafts were anchored onto the surface with indocyanine green-dyed albumin activated with an 810-nm diode laser. Histomorphologically, the postoperative results from three wounds were compared. The experimental wounds were completely covered by regenerated squamous cells in 1 week and by ciliated epithelium in 2 weeks after the operation despite the discrepancy in size of the graft to wound area (1:6.7) covered with the stamp mucosa. No thermal damage from the diode laser was noted in the second experimental wounds. In the control wounds, no coverage was observed at 1 week, and only squamous cells were noted 2 weeks postoperatively. All the wounds had normal ciliated epithelium coverage at 4 weeks. Transplanted stamp grafts provided similar or better healing than trapdoor flap transplants. This new technique made endoscopic mucosal grafting possible and offers a potential breakthrough in the management of laryngotracheal stenosis.

  10. Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation.

    Science.gov (United States)

    Bruegger, Lukas; Studer, Peter; Schmid, Stefan W; Pestel, Gunther; Reichen, Juerg; Seiler, Christian; Candinas, Daniel; Inderbitzin, Daniel

    2008-01-01

    Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI]=0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into account.

  11. Toxicity profiles of subretinal indocyanine green, Brilliant Blue G, and triamcinolone acetonide: a comparative study

    DEFF Research Database (Denmark)

    Ejstrup, Rasmus; Dornonville de la Cour, Morten; Heegaard, Steffen

    2012-01-01

    BACKGROUND: This study introduces a novel porcine model to examine the histopathological and electrophysiological consequences of retinotoxicity exerted by dyes commonly used for internal limiting membrane (ILM) staining. METHODS: Indocyanine green (ICG) 0.5 mg/ml, Brilliant Blue G (BBG) 0.25 mg....../ml and triamcinolone acetonide (TA) 13 mg/ml was injected subretinally in 12 vitrectomized pig eyes. At 6 weeks, retinas were examined by multifocal electroretinography (mfERG), ophthalmoscopy, fluorescein angiograpy, histopathology, and apoptosis assay. RESULTS: mfERG responses were significantly lower in ICG......-injected eyes than in healthy fellow eyes (p¿=¿0.039). The ratio between injected eyes and healthy fellow eyes was lower in the ICG group than in the BBG (p¿=¿0.009) and TA group (p¿=¿0.025). No difference between BBG and TA existed. All retinas were reattached, and fluorescein angiographies showed a window...

  12. Blood flow index using near-infrared spectroscopy and indocyanine green as a minimally invasive tool to assess respiratory muscle blood flow in humans

    DEFF Research Database (Denmark)

    Guenette, Jordan A; Henderson, William R; Dominelli, Paolo B

    2011-01-01

    Near-infrared spectroscopy (NIRS) in combination with indocyanine green (ICG) dye has recently been used to measure respiratory muscle blood flow (RMBF) in humans. This method is based on the Fick principle and is determined by measuring ICG in the respiratory muscles using transcutaneous NIRS...... relationships with the work of breathing and EMG for both respiratory muscles. The coefficients of determination (R(2)) comparing BFI vs. the work of breathing for the intercostal and sternocleidomastoid muscles were 0.887 (P

  13. Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental proof of the concept.

    Science.gov (United States)

    Diana, Michele; Liu, Yu-Yin; Pop, Raoul; Kong, Seong-Ho; Legnèr, Andras; Beaujeux, Remy; Pessaux, Patrick; Soler, Luc; Mutter, Didier; Dallemagne, Bernard; Marescaux, Jacques

    2017-03-01

    Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego ® , multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n = 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n = 1). Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.

  14. Indocyanine green videoangiography "in negative": definition and usefulness in intracranial dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Aparici Robles, Fernando; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2013-09-01

    Indocyanine green videoangiography (IGV) raises important limitations when we use it in vascular pathology, especially in cases with arterialization of the venous system such as arteriovenous malformations and fistulae. Our objective was to provide a simple procedure that overcomes the limitations of conventional IGV. We define IGV in negative (IGV-IN), so-called because, in its first phase, the vessel to analyze is clipped, and we report 3 cases of intracranial dural arteriovenous fistulae treated with this procedure. In 2011, we applied IGV-IN to 3 patients at our center with Borden type III intracranial arteriovenous fistulae. In all 3 cases, IGV-IN enabled both diagnosis and post-dural arteriovenous fistula exclusion control in 1 integrated procedure no longer than 1 minute, requiring only 1 visualization. IGV-IN is an improvement over the conventional IGV method and is able to provide more information in a shorter period of time. It is an intuitive and highly visual procedure, and, more importantly, it is reversible. Studies with larger samples are necessary to determine whether IGV-IN can further reduce the need for postoperative digital subtraction angiography.

  15. Lipid nanoparticle vectorization of indocyanine green improves fluorescence imaging for tumor diagnosis and lymph node resection.

    Science.gov (United States)

    Navarro, Fabrice P; Berger, Michel; Guillermet, Stéphanie; Josserand, Véronique; Guyon, Laurent; Neumann, Emmanuelle; Vinet, Françoise; Texier, Isabelle

    2012-10-01

    Fluorescence imaging is opening a new era in image-guided surgery and other medical applications. The only FDA approved contrast agent in the near infrared is IndoCyanine Green (ICG), which despites its low toxicity, displays poor chemical and optical properties for long-term and sensitive imaging applications in human. Lipid nanoparticles are investigated for improving ICG optical properties and in vivo fluorescence imaging sensitivity. 30 nm diameter lipid nanoparticles (LNP) are loaded with ICG. Their characterization and use for tumor and lymph node imaging are described. Nano-formulation benefits dye optical properties (6 times improved brightness) and chemical stability (>6 months at 4 degrees C in aqueous buffer). More importantly, LNP vectorization allows never reported sensitive and prolonged (>1 day) labeling of tumors and lymph nodes. Composed of human-use approved ingredients, this novel ICG nanometric formulation is foreseen to expand rapidly the field of clinical fluorescence imaging applications.

  16. Leveraging Engineering of Indocyanine Green-Encapsulated Polymeric Nanocomposites for Biomedical Applications.

    Science.gov (United States)

    Han, Ya-Hui; Kankala, Ranjith Kumar; Wang, Shi-Bin; Chen, Ai-Zheng

    2018-05-24

    In recent times, photo-induced therapeutics have attracted enormous interest from researchers due to such attractive properties as preferential localization, excellent tissue penetration, high therapeutic efficacy, and minimal invasiveness, among others. Numerous photosensitizers have been considered in combination with light to realize significant progress in therapeutics. Along this line, indocyanine green (ICG), a Food and Drug Administration (FDA)-approved near-infrared (NIR, >750 nm) fluorescent dye, has been utilized in various biomedical applications such as drug delivery, imaging, and diagnosis, due to its attractive physicochemical properties, high sensitivity, and better imaging view field. However, ICG still suffers from certain limitations for its utilization as a molecular imaging probe in vivo, such as concentration-dependent aggregation, poor in vitro aqueous stability and photodegradation due to various physicochemical attributes. To overcome these limitations, much research has been dedicated to engineering numerous multifunctional polymeric composites for potential biomedical applications. In this review, we aim to discuss ICG-encapsulated polymeric nanoconstructs, which are of particular interest in various biomedical applications. First, we emphasize some attractive properties of ICG (including physicochemical characteristics, optical properties, metabolic features, and other aspects) and some of its current limitations. Next, we aim to provide a comprehensive overview highlighting recent reports on various polymeric nanoparticles that carry ICG for light-induced therapeutics with a set of examples. Finally, we summarize with perspectives highlighting the significant outcome, and current challenges of these nanocomposites.

  17. Indocyanine green loaded graphene oxide for high-efficient photoacoustic tumor therapy

    Directory of Open Access Journals (Sweden)

    Baoyun Yan

    2016-07-01

    Full Text Available Photoacoustic therapy, using the photoacoustic effect of agents for selectively killing tumor cells, has shown promising for treating tumor. Utilization of high optical absorption probes can help to effectively improve the photoacoustic therapy efficiency. Herein, we report a novel high-absorption photoacoustic probe that is composed of indocyanine green (ICG and graphene oxide (GO, entitled GO-ICG, for photoacoustic therapy. The attached ICG with narrow absorption spectral profile has strong optical absorption in the infrared region. The absorption spectrum of the GO-ICG solution reveals that the GO-ICG particles exhibited a 10-fold higher absorbance at 780nm (its peak absorbance as compared with GO. Importantly, ICG’s fluorescence is quenched by GO via fluorescence resonance energy transfer. As a result, GO-ICG can high-efficiently convert the absorbed light energy to acoustic wave under pulsed laser irradiation. We further demonstrate that GO-ICG can produce stronger photoacoustic wave than the GO and ICG alone. Moreover, we conjugate this contrast agent with integrin αvβ3 mono-clonal antibody to molecularly target the U87-MG human glioblastoma cells for selective tumor cell killing. Finally, our results testify that the photoacoustic therapy efficiency of GO-ICG is higher than the existing photoacoustic therapy agent. Our work demonstrates that GO-ICG is a high-efficiency photoacoustic therapy agent. This novel photoacoustic probe is likely to be an available candidate for tumor therapy.

  18. Assessing pharmacokinetics of indocyanine green-loaded nanoparticle in tumor with a dynamic diffuse fluorescence tomography system

    Science.gov (United States)

    Zhang, Yanqi; Yin, Guoyan; Zhao, Huijuan; Ma, Wenjuan; Gao, Feng; Zhang, Limin

    2018-02-01

    Real-time and continuous monitoring of drug release in vivo is an important task in pharmaceutical development. Here, we devoted to explore a real-time continuous study of the pharmacokinetics of free indocyanine green (ICG) and ICG loaded in the shell-sheddable nanoparticles in tumor based on a dynamic diffuse fluorescence tomography (DFT) system: A highly-sensitive dynamic DFT system of CT-scanning mode generates informative and instantaneous sampling datasets; An analysis procedure extracts the pharmacokinetic parameters from the reconstructed time curves of the mean ICG concentration in tumor, using the Gauss-Newton scheme based on two-compartment model. Compared with the pharmacokinetic parameters of free ICG in tumor, the ICG loaded in the shell-sheddable nanoparticles shows efficient accumulation in tumor. The results demonstrate our proposed dynamic-DFT can provide an integrated and continuous view of the drug delivery of the injected agents in different formulations, which is helpful for the development of diagnosis and therapy for tumors.

  19. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  20. Development and validation of a custom made indocyanine green fluorescence lymphatic vessel imager

    Science.gov (United States)

    Pallotta, Olivia J.; van Zanten, Malou; McEwen, Mark; Burrow, Lynne; Beesley, Jack; Piller, Neil

    2015-06-01

    Lymphoedema is a chronic progressive condition often producing significant morbidity. An in-depth understanding of an individual's lymphatic architecture is valuable both in the understanding of underlying pathology and for targeting and tailoring treatment. Severe lower limb injuries resulting in extensive loss of soft tissue require transposition of a flap consisting of muscle and/or soft tissue to close the defect. These patients are at risk of lymphoedema and little is known about lymphatic regeneration within the flap. Indocyanine green (ICG), a water-soluble dye, has proven useful for the imaging of lymphatic vessels. When injected into superficial tissues it binds to plasma proteins in lymph. By exposing the dye to specific wavelengths of light, ICG fluoresces with near-infrared light. Skin is relatively transparent to ICG fluorescence, enabling the visualization and characterization of superficial lymphatic vessels. An ICG fluorescence lymphatic vessel imager was manufactured to excite ICG and visualize real-time fluorescence as it travels through the lymphatic vessels. Animal studies showed successful ICG excitation and detection using this imager. Clinically, the imager has assisted researchers to visualize otherwise hidden superficial lymphatic pathways in patients postflap surgery. Preliminary results suggest superficial lymphatic vessels do not redevelop in muscle flaps.

  1. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  2. Imaging of pharmacokinetic rates of indocyanine green in mouse liver with a hybrid fluorescence molecular tomography/x-ray computed tomography system.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Zhang, Bin; He, Yun; Luo, Jianwen; Bai, Jing

    2013-04-01

    Pharmacokinetic rates have the potential to provide quantitative physiological and pathological information for biological studies and drug development. Fluorescence molecular tomography (FMT) is an attractive imaging tool for three-dimensionally resolving fluorophore distribution in small animals. In this letter, pharmacokinetic rates of indocyanine green (ICG) in mouse liver are imaged with a hybrid FMT and x-ray computed tomography (XCT) system. A recently developed FMT method using structural priors from an XCT system is adopted to improve the quality of FMT reconstruction. In the in vivo experiments, images of uptake and excretion rates of ICG in mouse liver are obtained, which can be used to quantitatively evaluate liver function. The accuracy of the results is validated by a fiber-based fluorescence measurement system.

  3. Indocyanine green labeled with /sup 123/I for dynamic studies of the hepato-biliary system. [/sup 131/I, /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub /sup 1///sub 2// = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of /sup 123/I-ICG (in dogs) will be compared to /sup 131/I-rose bengal and bromosulphalein labeled with iodine-125.

  4. Indocyanine Green-Loaded Polydopamine-Reduced Graphene Oxide Nanocomposites with Amplifying Photoacoustic and Photothermal Effects for Cancer Theranostics.

    Science.gov (United States)

    Hu, Dehong; Zhang, Jingnan; Gao, Guanhui; Sheng, Zonghai; Cui, Haodong; Cai, Lintao

    2016-01-01

    Photoacoustic (PA) imaging and photothermal therapy (PTT) as light-induced theranostic platforms have been attracted much attention in recent years. However, the development of highly efficient and integrated phototheranostic nanoagents for amplifying PA imaging and PTT treatments poses great challenges. Here, we report a novel phototheranostic nanoagent using indocyanine green-loaded polydopamine-reduced graphene oxide nanocomposites (ICG-PDA-rGO) with amplifying PA and PTT effects for cancer theranostics. The results demonstrate that the PDA layer coating on the surface of rGO could effectively absorb a large number of ICG molecules, quench ICG's fluorescence, and enhance the PDA-rGO's optical absorption at 780 nm. The obtained ICG-PDA-rGO exhibits stronger PTT effect and higher PA contrast than that of pure GO and PDA-rGO. After PA imaging-guided PTT treatments, the tumors in 4T1 breast subcutaneous and orthotopic mice models are suppressed completely and no treatment-induced toxicity being observed. It illustrates that the ICG-PDA-rGO nanocomposites constitute a new class of theranostic nanomedicine for amplifying PA imaging and PTT treatments.

  5. Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain

    Science.gov (United States)

    Gerega, Anna; Milej, Daniel; Weigl, Wojciech; Botwicz, Marcin; Zolek, Norbert; Kacprzak, Michal; Wierzejski, Wojciech; Toczylowska, Beata; Mayzner-Zawadzka, Ewa; Maniewski, Roman; Liebert, Adam

    2012-08-01

    Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is presented and advantages of measurements at multiple wavelengths are discussed. Measurements were carried out: 1. on a physical homogeneous phantom to study the concentration dependence of the fluorescence signal, 2. on the phantom to simulate the dynamic inflow of ICG at different depths, and 3. in vivo on surface of the human head. Pattern of inflow and washout of ICG in the head of healthy volunteers after intravenous injection of the dye was observed for the first time with time-resolved instrumentation at multiple emission wavelengths. The multiwavelength detection of fluorescence signal confirms that at longer emission wavelengths, probability of reabsorption of the fluorescence light by the dye itself is reduced. Considering different light penetration depths at different wavelengths, and the pronounced reabsorption at longer wavelengths, the time-resolved multiwavelength technique may be useful in signal decomposition, leading to evaluation of extra- and intracerebral components of the measured signals.

  6. Tailoring through Technology: A Retrospective Review of a Single Surgeon's Experience with Implant-Based Breast Reconstruction before and after Implementation of Laser-Assisted Indocyanine Green Angiography.

    Science.gov (United States)

    Harless, Christin A; Jacobson, Steven R

    2016-05-01

    Reported complication rates of implant-based breast reconstruction in the literature exceed 50%, with mastectomy skin flap necrosis reported to occur in up to 25% of cases. Laser-assisted indocyanine green angiography (LA-ICGA) technology allows the surgeon to optimize preservation of the mastectomy skin flap while avoiding skin necrosis. The purpose of this study was to determine if outcomes of breast reconstruction are beneficially affected by using LA-ICGA. A total 269 consecutive women (467 breast reconstructions) undergoing implant-based breast reconstruction from 2008 to 2013 were examined. The complication rates of those who underwent reconstruction prior to the implementation of LA-ICGA were compared with those who were reconstructed after implementation of LA-ICGA. A total of 254 consecutive breast reconstructions were performed prior to implementation of LA-ICGA, and 213 breasts were reconstructed with the use of LA-ICGA. After implementation of LA-ICGA System, the rate of mastectomy skin flap necrosis decreased by 86% (6.7% versus 0.9%, p = 0.02). The overall complication rate prior to LA-ICGA was 13.8% compared with 6.6% with the use of LA-ICGA (p = 0.01). After LA-ICGA was incorporated, the percentage of patients undergoing single-stage reconstruction increased from 12% to 32% (p = <0.001). Implementation of LA-ICGA provides the surgeon with an objective assessment of mastectomy flap perfusion resulting in a trend toward overall reduction in complications as well as an 86% decrease in the rate of subsequent skin necrosis. The objective assessment of mastectomy flap perfusion allows the surgeon to tailor breast reconstruction intraoperatively, in real-time, adjusting for the individual patient's mastectomy flap perfusion. © 2016 Wiley Periodicals, Inc.

  7. [Place of indocyanine green coupled with fluorescence imaging in research of breast cancer sentinel node].

    Science.gov (United States)

    Vermersch, Charlotte; Raia Barjat, Tiphaine; Perrot, Marianne; Lima, Suzanne; Chauleur, Céline

    2016-04-01

    The sentinel node has a fundamental role in the management of early breast cancer. Currently, the double detection of blue and radioisotope is recommended. But in common practice, many centers use a single method. However, with a single detection, the risk of false negatives and the identification failure rate increase to a significant extent and the number of sentinel lymph node detected and removed is not enough. Furthermore, the tracers used until now show inconveniences. The purpose of this work is to present a new method of detection, using the green of indocyanine coupled with fluorescence imaging, and to compare it with the already existing methods. The method combined by fluorescence and isotopic is reliable, sure, of fast learning and could constitute a good strategy of detection. The major interest is to obtain a satisfactory number of sentinel nodes. The profit could be even more important for overweight patients. The fluorescence used alone is at the moment not possible. Wide ranging studies are necessary. The FLUOTECH, randomized study of 100 patients, comparing the isotopic method of double isotope technique and fluorescence, is underway to confirm these data. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  8. infrared spectrophotometer for simultaneous detection of traces of heavy water and indocyanine green in flowing blood. In vivo experimentation

    International Nuclear Information System (INIS)

    Capitini, R.; Roveyaz, P.

    1981-07-01

    We have developed an infrared absorption method for the pulmonary extravascular water and cardiac output determination by the multiple indicator technique. This led us to construct an original double differential spectrophotometer (DUPLEX) for simultaneous detection of traces of heavy water (D 2 O) and indocyanine green (ICG) in circulating blood in a single absorption cell. This DUPLEX is connected to a computer and results are treated on line. D 2 O and ICG are used as non toxic diffusible and vascular tracers respectively. Performances of the DUPLEX are given and show a high accuracy with D 2 O (x 10) and ICG (x 2) compared with the commercial optical analysers. We show the validity of the method for determining the cardiac output and the pulmonary extravascular water in the course of numerous experiments on human and rats subjects. Preliminary results concerning the measurement of global water on rats are also given [fr

  9. 1,213 Cases of Treatment of Facial Acne Using Indocyanine Green and Intense Pulsed Light in Asian Skin

    Directory of Open Access Journals (Sweden)

    Kui Young Park

    2015-01-01

    Full Text Available Background. Photodynamic therapy (PDT has been used for acne, with various combinations of photosensitizers and light sources. Objective. We evaluated the effectiveness and safety of indocyanine green (ICG and intense pulsed light (IPL in the treatment of acne. Materials and Methods. A total of 1,213 patients with facial acne were retrospectively reviewed. Patients received three or five treatments of ICG and IPL at two-week intervals. Clinical response to treatment was assessed by comparing pre- and posttreatment clinical photographs and patient satisfaction scores. Results. Marked to excellent improvement was noted in 483 of 1,213 (39.8% patients, while minimal to moderate improvement was achieved in the remaining 730 (60.2% patients. Patient satisfaction scores revealed that 197 (16.3% of 1,213 patients were highly satisfied, 887 (73.1% were somewhat satisfied, and 129 (10.6% were unsatisfied. There were no significant side effects. Conclusion. These results suggest that PDT with ICG and IPL can be effectively and safely used in the treatment of acne.

  10. Utility of Indocyanine Green Video Angiography for Sylvian Fissure Dissection in Subarachnoid Hemorrhage Patients - Sylvian ICG Technique.

    Science.gov (United States)

    Toi, Hiroyuki; Matsushita, Nobuhisa; Ogawa, Yukari; Kinoshita, Keita; Satoh, Kohei; Takai, Hiroki; Hirai, Satoshi; Hara, Keijiro; Matsubara, Shunji; Uno, Masaaki

    2018-02-15

    Indocyanine green (ICG) emits fluorescence in the far-red domain under light excitation. ICG video angiography (ICG-VA) has been established as a useful method to evaluate blood flow in the operative field. We report the usefulness of ICG-VA for Sylvian fissure dissection in patients with subarachnoid hemorrhage (SAH). Subjects comprised 7 patients who underwent ICG-VA before opening the Sylvian fissure during neck clipping for ruptured cerebral aneurysm. We observed contrasted Sylvian veins before opening the Sylvian fissure using surgical microscopes. This procedure was termed "Sylvian ICG". We observed ICG fluorescence quickly in all cases. Sylvian veins that appeared unclear in the standard microscopic operative field covered with subarachnoid hemorrhage were extremely clearly depicted. These Sylvian ICG findings were helpful in identifying entry points and the dissecting course of the Sylvian fissure. At the time of clipping, no residual fluorescence from Sylvian ICG was present, and aneurysm clipping was not impeded. Sylvian ICG for SAH patients is a novel technique to facilitate dissection of the Sylvian fissure. We believe that this technique will contribute to improved safety of clipping surgery for ruptured aneurysms.

  11. In vitro efficiency and mechanistic role of indocyanine green as photodynamic therapy agent for human melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.M.; Miller, L.; Gamal-Eldeen, A. M.; Ruppel, M. E.; Smith, R. J.; Tsang, T.; Miller, L. M.

    2009-05-02

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800 nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway. Human skin melanoma cells (Sk-Mel-28) were incubated with ICG and exposed to a low power Ti:Sapphire laser. Synchrotron-assisted Fourier transform infrared microspectroscopy and hierarchical cluster analysis were used to assess the cell damage and changes in lipid, protein, and nucleic acids. The cell death pathway was determined by analysis of cell viability and apoptosis and necrosis markers. In the cell death pathway, {sup 1}O{sub 2} generation evoked rapid multiple consequences that trigger apoptosis after laser exposure for only 15min including the release of cytochrome c, the activation of total caspases, caspase-3, and caspase-9, the inhibition of NF-{Kappa}B P65, and the enhancement of DNA fragmentation, and histone acetylation. ICG/PDT can efficiently and rapidly induce apoptosis in human melanoma cells and it can be considered as a new therapeutic approach for topical treatment of melanoma.

  12. Thermal and infrared-diode laser effects on indocyanine-green-treated corneal collagen

    Science.gov (United States)

    Timberlake, George T.; Patmore, Ann; Shallal, Assaad; McHugh, Dominic; Marshall, John

    1993-07-01

    It has been suggested that laser welds of collagenous tissues form by interdigitation and chemical bonding of thermally 'unraveled' collagen fibrils. We investigated this proposal by attempting to weld highly collagenous, avascular corneal tissue with an infrared (IR) diode laser as follows. First, the temperature at which corneal collagen shrinks and collagen fibrils 'split' into subfibrillary components was determined. Second, since use of a near-IR laser wavelength necessitated addition of an absorbing dye (indocyanine green (ICG) to the cornea, we measured absorption spectra of ICG-treated tissue to ensure that peak ICG absorbance did not change markedly when ICG was present in the cornea. Third, using gel electrophoresis of thermally altered corneal collagen, we searched for covalently crosslinked compounds predicted by the proposed welding mechanism. Finally, we attempted to weld partial thickness corneal incisions infused with ICG. Principal experimental findings were as follows: (1) Human corneal (type I) collagen splits into subfibrillary components at approximately 63 degree(s)C, the same temperature that produces collagen shrinkage. (2) Peak ICG absorption does not change significantly in corneal stroma or with laser heating. (3) No evidence was found for the formation of novel compounds or the loss of proteins as a result of tissue heating. All tissue treated with ICG, however, exhibited a novel 244 kD protein band indicating chemical activity between collagen and corneal stromal components. (4) Laser welding corneal incisions was unsuccessful possibly due to shrinkage of the sides of the incision, lack of incision compression during heating, or a less than optimal combination of ICG concentration and radiant exposure. In summary, these experiments demonstrate the biochemical and morphological complexity of ICG-enhanced IR laser-tissue welding and the need for further investigation of laser welding mechanisms.

  13. A novel duct-lobular segmentectomy for breast tumors with nipple discharge using near-infrared indocyanine green fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohno

    2013-10-01

    Full Text Available A 44-year-old woman was referred to our hospital with pathological nipple discharge from her left breast. Ultrasonography revealed a solid tumor beneath her left areola that measured 17 mm in diameter with a dilated mammary duct. Contrast-enhanced magnetic resonance imaging showed an early-enhanced cystic tumor and a dilated mammary duct. We performed a duct-lobular segmentectomy using near-infrared indocyanine green (ICG-fluorescence imaging. Under general anesthesia, a silicone tube was inserted into an orifice of a fluid-discharging mammary duct, and 1 mL dye-fluorescence liquid containing ICG and indigo carmine was injected into the mammary duct. A periareolar incision was made, and the fluorescence image of the demarcated mammary duct segment was obtained. The mammary duct segment was dissected, along with the demarcation line. The cystic lesion and dilated mammary duct were fully resected, and the pathological diagnosis was intraductal papilloma of the breast. We report that near-infrared ICG fluorescence could be applied for imaging of the mammary duct segment, and the fluorescence image allowed for easier duct-lobular segmentectomy for nipple discharge.

  14. Indocyanine Green Angiographic and Multifocal Electroretinographic Features in the Diffuse and Regional Form of Bietti′s Crystalline Retinopathy

    Institute of Scientific and Technical Information of China (English)

    Libin Jiang; Feng Wen; Lezheng Wu; Hong Yan; Shixing Hu

    2002-01-01

    Prpose: To observe different features of indocyanine green angiography(ICGA) andtifocal electroretinography (ERG) in the diffuse and regional type of Bieti′sc stalline retinopathy (BCR). Thods: ICGA and the multifocal ERG were performed in two cases of the diffuse andregional type of BCR respectively. These data were compared with fluoresceinangiography (FA), standard Ganzfeld ERG, and visual field testing. Results: In the regional case, ICGA revealed reduced perfusion of the choroidalcirculation in the early phase and multiple hypofluorescent spots in the posterior pole in the late phase, due to choriocapillaris filling defect; the extent of choroiocapillaris losswas shown in early phase of ICGA and there were multifocal hyperfluorescent dotssurrounding hypofluorescent spots in late phase in the diffuse case. The multifocal ERGshowed that the central responses were markedly depressed, corresponding to the visualfield defects, while the findings of Ganzfeld ERG were normal in the regional BCR;however, both the multifocal ERG and Ganzfeld ERG were severely subnormal in thediffuse case.Conclusions: The features of ICGA and multifocal ERG are different between the diffuseand regional BCR. In the meantime, the two tools are also useful to differentiate the typeand assess the extentof evolution in BCR.

  15. Detection of posterior vortex veins in eyes with pathologic myopia by ultra-widefield indocyanine green angiography.

    Science.gov (United States)

    Moriyama, Muka; Cao, Kejia; Ogata, Satoko; Ohno-Matsui, Kyoko

    2017-09-01

    To analyse the characteristics of posterior vortex veins detected in highly myopic eyes by wide-field indocyanine green angiography (ICGA). One hundred and fifty-eight consecutive patients (302 eyes) with high myopia (myopic refractive error >8.0 dioptres (D) or axial length ≥26.5 mm) were studied. Wide-field ICGA was performed with the Spectralis HRA module. Posterior vortex veins were found in 80 eyes (26%). The prevalence of posterior staphyloma was significantly higher in eyes in which posterior vortex vein was detected than in eyes without posterior vortex vein. The posterior vortex veins were classified into five types according to the site of exit from the eye; around the optic nerve in 28%, in the macular area in 17%, along the border of staphyloma in 6%, along the margin of macular atrophy or large peripapillary conus in 21%, and elsewhere in 28%. In one eye, two posterior vortex veins collected the choroidal venous blood from the entire fundus. Wide-field ICGA can analyse the characteristic features of choroidal blood outflow system through posterior vortex veins in highly myopic eyes. They may play an important role as routes of choroidal outflow in highly myopic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Development of PLGA-lipid nanoparticles with covalently conjugated indocyanine green as a versatile nanoplatform for tumor-targeted imaging and drug delivery

    Directory of Open Access Journals (Sweden)

    Xin Y

    2016-11-01

    Full Text Available Yu Xin, Tie Liu, Chenlong Yang Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, People’s Republic of China Abstract: We have prepared novel poly(d,l-lactide-co-glycolide (PLGA lipid nanoparticles (PNPs that covalently conjugate folic acid (FA and indocyanine green (ICG, in addition to encapsulating resveratrol (RSV (FA-RSV/ICG-PLGA-lipid NPs, abbreviated as FA-RIPNPs; these nanoparticles have been developed for simultaneous targeted delivery of anticancer drug and fluorescence imaging. The FA-RIPNPs, with an average particle size of 92.8±2.1 nm, were prepared by a facile self-assembly-and-nanoprecipitation method, and they showed excellent stability and biocompatibility characteristics. The FA-RIPNPs exhibited an RSV encapsulation efficiency of approximately 65.6%±4.7% and a maximum release ratio of 78.2%±4.1% at pH 5.0 and 37°C. Confocal fluorescence images showed that FA-RIPNPs may facilitate a high cellular uptake via FA receptor-mediated endocytosis. Furthermore, FA-RIPNPs (containing 50 µg/mL RSV induced a 81.4%±2.1% U87 cell inhibition rate via apoptosis, a value that proved to be higher than what has been shown for free RSV (53.1%±1.1%, equivalent RSV concentration. With a formulated polyethylene glycol (PEG shell around the PLGA core, FA-RIPNPs prolonged the blood circulation of both free RSV and ICG, which approximately increased 6.96- and 39.4-fold (t1/2, respectively. Regarding FA-RIPNP use as a near-infrared probe, in vivo fluorescence images indicated a highly efficient accumulation of FA-RIPNPs in the tumor tissue, which proved to be approximately 2.8- and 12.6-fold higher than the RIPNPs and free ICG, respectively. Intravenous injection of FA-RIPNPs into U87 tumor-bearing mice demonstrated the best tumor inhibition effect for all tested drugs, including free RSV and RIPNPs, with no relapse, showing high biocompatibility and with no significant systemic in vivo toxicity over the

  17. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  18. Use of invisible near infrared light fluorescence with indocyanine green and methylene blue in urology. Part 2.

    Science.gov (United States)

    Polom, Wojciech; Markuszewski, Marcin; Rho, Young Soo; Matuszewski, Marcin

    2014-01-01

    In the second part of this paper, concerning the use of invisible near infrared light (NIR) fluorescence with indocyanine green (ICG) and methylene blue (MB) in urology, other possible uses of this new technique will be presented. In kidney transplantation, this concerns allograft perfusion and real time NIR-guided angiography; moreover, perfusion angiography of tissue flaps, NIRF visualization of ureters, NIR-guided visualization of urinary calcifications, NIRF in male infertility and semen quality assessment. In this part, we have also analysed cancer targeting and imaging fluorophores as well as cost benefits associated with the use of these new techniques. PubMed and Medline databases were searched for ICG and MB use in urological settings, along with data published in abstracts of urological conferences. Although NIR-guided ICG and MB are still in their initial phases, there have been significant developments in a few more major domains of urology, including 1) kidney transplantation: kidney allograft perfusion and vessel reconstruction; 2) angiography perfusion of tissue flaps; 3) visualization of ureters; 4) visualization of urinary calcifications; and 5) NIRF in male infertility and semen quality assessment. Near infrared technology in urology is at its early stages. More studies are needed to assess the true potential and limitations of the technology. Initial studies show that this pioneering tool may influence various aspects of urology.

  19. Intraoperative near-infrared fluorescent imaging during robotic operations.

    Science.gov (United States)

    Macedo, Antonio Luiz de Vasconcellos; Schraibman, Vladimir

    2016-01-01

    The intraoperative identification of certain anatomical structures because they are small or visually occult may be challenging. The development of minimally invasive surgery brought additional difficulties to identify these structures due to the lack of complete tactile sensitivity. A number of different forms of intraoperative mapping have been tried. Recently, the near-infrared fluorescence imaging technology with indocyanine green has been added to robotic platforms. In addition, this technology has been tested in several types of operations, and has advantages such as safety, low cost and good results. Disadvantages are linked to contrast distribution in certain clinical scenarios. The intraoperative near-infrared fluorescent imaging is new and promising addition to robotic surgery. Several reports show the utility of this technology in several different procedures. The ideal dose, time and site for dye injection are not well defined. No high quality evidence-based comparative studies and long-term follow-up outcomes have been published so far. Initial results, however, are good and safe. RESUMO A identificação intraoperatória de certas estruturas anatômicas, por seu tamanho ou por elas serem ocultas à visão, pode ser desafiadora. O desenvolvimento da cirurgia minimamente invasiva trouxe dificuldades adicionais, pela falta da sensibilidade tátil completa. Diversas formas de detecção intraoperatória destas estruturas têm sido tentadas. Recentemente, a tecnologia de fluorescência infravermelha com verde de indocianina foi associada às plataformas robóticas. Além disso, essa tecnologia tem sido testada em uma variedade de cirurgias, e suas vantagens parecem estar ligadas a baixo custo, segurança e bons resultados. As desvantagens estão associadas à má distribuição do contraste em determinados cenários. A imagem intraoperatória por fluorescência infravermelha é uma nova e promissora adição à cirurgia robótica. Diversas séries mostram

  20. Indocyanine green-assisted internal limiting membrane peeling in macular hole surgery: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yan Wu

    Full Text Available BACKGROUND: The opinion of application of indocyanine green (ICG in the macular hole surgery was contradictory. Here we conducted a meta-analysis to evaluate the effect of in internal limiting membrane (ILM peeling for macular hole surgery. METHODS AND FINDINGS: We searched electronic databases for comparative studies published before July 2012 of ILM peeling with and without ICG. Twenty-two studies including 1585 eyes were included. Visual acuity (VA improvement, including the postoperative rate of ≥20/40 VA gained (OR, 0.65; 95% CI, 0.43 to 0.97; P = 0.033 and increased LogMAR (WMD, -0.09; 95% CI, -0.16 to -0.02; P = 0.011, was less in the ICG group. The risk of visual field defects was greater in the ICG group than in the non-ICG group. There was no significant difference in the rate of anatomical outcomes between ILM peeling procedures performed with and without ICG. RPE changes and other postoperative complications were not significantly different between the ICG and non-ICG groups. An additional analysis showed that the VA improvement of the ICG group was less than the non-ICG group only within the first year of follow up. A subgroup analysis showed that the rate of VA improvement was lower in the ICG group than in other adjuncts group. A higher rate of secondary closure and less VA improvement were observed in a high proportion (>0.1% of the ICG group. A sensitivity analysis after the randomized-controlled trials were excluded from the meta-analysis demonstrated no differences compared with the overall results. CONCLUSIONS: This meta-analysis demonstrated that there is no evidence of clinical superiority in outcomes for ICG-assisted ILM peeling procedure over the non-ICG one. The toxicity of ICG should be considered when choosing the various staining methods.

  1. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  2. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  3. Impact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Tamer Tandogan

    2016-01-01

    Full Text Available Purpose. To investigate the role of indocyanine green (ICG dye as a causative material of toxic anterior segment syndrome (TASS in an experimental rabbit model. Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%, exposure times (10 and 60 seconds, and the degree of dissolution (differently vortexed were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2 Parameter Assay, R&D systems, Inc., and scanning electron microscopy of each iris. Result. There was no reaction in the control eye. A higher aqueous level of PGE2 and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles. Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.

  4. Prussian blue/serum albumin/indocyanine green as a multifunctional nanotheranostic agent for bimodal imaging guided laser mediated combinatorial phototherapy.

    Science.gov (United States)

    Sahu, Abhishek; Lee, Jong Hyun; Lee, Hye Gyeong; Jeong, Yong Yeon; Tae, Giyoong

    2016-08-28

    Developing novel nanotheranostic agent using only clinically approved materials is highly desirable and challenging. In this study, we combined three clinically approved materials, Prussian blue (PB), serum albumin (BSA), and indocyanine green (ICG), by a simple and biocompatible method to prepare a multifunctional theranostic PB-BSA-ICG nanoparticle. The multifunctional nanoparticle system could provide dual mode magnetic resonance (MR) and near infrared (NIR) fluorescence imaging as well as combined photothermal and photodynamic (PTT-PDT) therapy in response to a single NIR laser. This nanoparticle showed an excellent stability in physiological solutions and could suppress the photo-instability of ICG. In the absence of light, the nanoparticles showed no cytotoxicity, but significant cell death was induced through combined PTT-PDT effect after irradiation with NIR laser light. A high tumor accumulation and minimal nonspecific uptake by other major organs of PB-BSA-ICG nanoparticle were observed in vivo, analyzed by T1-weighted MR and NIR fluorescence bimodal imaging in tumor xenograft mice after intravenous injection. The nanoparticles efficiently suppressed the tumor growth through combinatorial phototherapy with no tumor recurrence upon a single NIR laser irradiation. These results demonstrated that PB-BSA-ICG is potentially an interesting nanotheranostic agent for imaging guided cancer therapy by overcoming the limitations of each technology and enhancing the therapeutic efficiency as well as reducing side effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Preliminary study of laser welding for aortic dissection in a porcine model using a diode laser with indocyanine green.

    Science.gov (United States)

    Fujita, Masanori; Morimoto, Yuji; Ohmori, Sayaka; Usami, Noriko; Arai, Tsunenori; Maehara, Tadaaki; Kikuchi, Makoto

    2003-01-01

    The objective of this study was to determine whether a dissected aorta could be welded by a diode laser with a solder using an in vitro porcine aortic dissection model. Porcine aortic strips were dissected into two flaps and the dissected faces were immersed in a solution of indocyanine green. The two flaps were pressed at 0.2 kg/cm2 with contact between the two immersed faces. The pressed flaps were irradiated with a diode laser (810 nm) at intensities of 170-425 W/cm2 for 8 seconds. The welded flaps were studied by light microscopy and the adhesive strengths were measured. The irradiated flaps were successfully welded. The breaking stress, the maximum stress recorded in a stress-strain curve, increased with increase in irradiation intensity up to 396 W/cm2 (2.7 x 10(2) mmHg) and decreased when the intensity reached 425 W/cm2. In the specimen irradiated at 396 W/cm2, the welded faces showed continuous fusion of elastin layers, while some voids were seen between the welded faces in the specimen irradiated at 425 W/cm2. The dissected porcine aortas were successfully welded using a laser with solder. The results suggest that the welded aorta can bear physiological blood pressure. Copyright 2003 Wiley-Liss, Inc.

  6. Near-infrared fluorescence imaging and photodynamic therapy with indocyanine green lactosome has antineoplastic effects for hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Takumi Tsuda

    Full Text Available Anticancer agents and operating procedures have been developed for hepatocellular carcinoma (HCC patients, but their prognosis remains poor. It is necessary to develop novel diagnostic and therapeutic strategies for HCC to improve its prognosis. Lactosome is a core-shell-type polymeric micelle, and enclosing labeling or anticancer agents into this micelle enables drug delivery. In this study, we investigated the diagnostic and therapeutic efficacies of indocyanine green (ICG-loaded lactosome for near-infrared fluorescence (NIF imaging and photodynamic therapy (PDT for HCC.The human HCC cell line HuH-7 was treated with ICG or ICG-lactosome, followed by PDT, and the cell viabilities were measured (in vitro PDT efficiency. For NIF imaging, HuH-7 cells were subcutaneously transplanted into BALB/c nude mice, followed by intravenous administration of ICG or ICG-lactosome. The transplanted animals were treated with PDT, and the antineoplastic effects were analyzed (in vivo PDT efficiency.PDT had toxic effects on HuH-7 cells treated with ICG-lactosome, but not ICG alone. NIF imaging revealed that the fluorescence of tumor areas in ICG-lactosome-treated animals was higher than that of contralateral regions at 24 h after injection and thereafter. PDT exerted immediate and continuous phototoxic effects in the transplanted mice treated with ICG-lactosome.Our results demonstrate that ICG-lactosome accumulated in xenograft tumors, and that PDT had antineoplastic effects on these malignant implants. NIF imaging and PDT with ICG-lactosome could be useful diagnostic and/or therapeutic strategies for HCC.

  7. The Role of Intraoperative Cerebral Angiography in Transorbital Intracranial Penetrating Trauma: A Case Report and Literature Review.

    Science.gov (United States)

    Riley, Jonathan P; Boucher, Andrew B; Kim, Denise S; Barrow, Daniel L; Reynolds, Matthew R

    2017-01-01

    Transorbital intracranial penetrating trauma with a retained intracranial foreign body is a rare event lacking a widely accepted diagnostic and therapeutic algorithm. Intraoperative catheter angiography (IOA) has been advocated by some authorities to rule out cerebrovascular injury before and/or after removal of the object, but no standard of care currently exists. A 19-year-old man was involved in a construction site accident whereby a framing nail penetrated the left globe, traversed the lateral bony orbit, and terminated in the midtemporal lobe. No hematoma or injury to the middle cerebral arteries (MCAs) was apparent on noncontrast head computed tomography (CT) or CT angiography, respectively. The foreign body was removed in the operating room under direct visualization after a frontotemporal craniotomy without incident. No significant venous or arterial bleeding was encountered. All visualized MCA branches appeared intact. Indocyanine green videoangiography performed immediately after object removal showed adequate filling of the MCA branches. Given these uneventful clinical and radiographic findings, IOA was not performed. Postoperative head CT and CT angiography showed no obvious neurovascular injury. On postoperative day 2, the patient was noted to have an expressive aphasia. Cerebral angiography showed absent antegrade filling of the angular artery with some retrograde perfusion. Magnetic resonance imaging confirmed an ischemic infarction in the midtemporal lobe. The patient's expressive aphasia improved to near baseline during his hospitalization and he made an excellent clinical recovery. In transorbital intracranial penetrating trauma with a retained intracranial object, we advocate microsurgical removal of the object under direct visualization followed immediately by IOA. IOA should be strongly considered even in the setting of minimal intraoperative bleeding and normal findings on videoangiography (a course of action that was not followed in the

  8. Organic Alternatives to Quantum Dots for Intraoperative Near-Infrared Fluorescent Sentinel Lymph Node Mapping

    Directory of Open Access Journals (Sweden)

    Shunsuke Ohnishi

    2005-07-01

    Full Text Available Intraoperative near-infrared (NIR fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs for sentinel lymph node (SLN mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800, emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.

  9. Intradermal indocyanine green for in vivo fluorescence laser scanning microscopy of human skin: a pilot study.

    Directory of Open Access Journals (Sweden)

    Constanze Jonak

    Full Text Available BACKGROUND: In clinical diagnostics, as well as in routine dermatology, the increased need for non-invasive diagnosis is currently satisfied by reflectance laser scanning microscopy. However, this technique has some limitations as it relies solely on differences in the reflection properties of epidermal and dermal structures. To date, the superior method of fluorescence laser scanning microscopy is not generally applied in dermatology and predominantly restricted to fluorescein as fluorescent tracer, which has a number of limitations. Therefore, we searched for an alternative fluorophore matching a novel skin imaging device to advance this promising diagnostic approach. METHODOLOGY/PRINCIPAL FINDINGS: Using a Vivascope®-1500 Multilaser microscope, we found that the fluorophore Indocyanine-Green (ICG is well suited as a fluorescent marker for skin imaging in vivo after intradermal injection. ICG is one of few fluorescent dyes approved for use in humans. Its fluorescence properties are compatible with the application of a near-infrared laser, which penetrates deeper into the tissue than the standard 488 nm laser for fluorescein. ICG-fluorescence turned out to be much more stable than fluorescein in vivo, persisting for more than 48 hours without significant photobleaching whereas fluorescein fades within 2 hours. The well-defined intercellular staining pattern of ICG allows automated cell-recognition algorithms, which we accomplished with the free software CellProfiler, providing the possibility of quantitative high-content imaging. Furthermore, we demonstrate the superiority of ICG-based fluorescence microscopy for selected skin pathologies, including dermal nevi, irritant contact dermatitis and necrotic skin. CONCLUSIONS/SIGNIFICANCE: Our results introduce a novel in vivo skin imaging technique using ICG, which delivers a stable intercellular fluorescence signal ideal for morphological assessment down to sub-cellular detail. The application of

  10. Effects of nanoencapsulation and PEGylation on biodistribution of indocyanine green in healthy mice: quantitative fluorescence imaging and analysis of organs

    Directory of Open Access Journals (Sweden)

    Bahmani B

    2013-04-01

    Full Text Available Baharak Bahmani,1 Christian Y Lytle,2 Ameae M Walker,2 Sharad Gupta,1 Valentine I Vullev,1 Bahman Anvari1 1Department of Bioengineering, 2Division of Biomedical Sciences, University of California, Riverside, CA, USA Abstract: Near-infrared nanoconstructs present a potentially effective platform for site-specific and deep tissue optical imaging and phototherapy. We have engineered a polymeric nanocapsule composed of polyallylamine hydrochloride (PAH chains cross-linked with sodium phosphate and doped with indocyanine green (ICG toward such endeavors. The ICG-doped nanocapsules were coated covalently with polyethylene glycol (5000 daltons through reductive amination. We administrated the constructs by tail vein injection to healthy mice. To characterize the biodistribution of the constructs, we performed in vivo quantitative fluorescence imaging and subsequently analyzed the various extracted organs. Our results suggest that encapsulation of ICG in these PEGylated constructs is an effective approach to prolong the circulation time of ICG and delay its hepatic accumulation. Increased bioavailability of ICG, due to encapsulation, offers the potential of extending the clinical applications of ICG, which are currently limited due to rapid elimination of ICG from the vasculature. Our results also indicate that PAH and ICG-doped nanocapsules (ICG-NCs are not cytotoxic at the levels used in this study. Keywords: cancer, fluorescent imaging, nanoprobes, near infrared, pharmacokinetics, phototherapy, vascular imaging

  11. The Predictive Value of Indocyanine Green Clearance in Future Liver Remnant for Posthepatectomy Liver Failure Following Hepatectomy with Extrahepatic Bile Duct Resection.

    Science.gov (United States)

    Yokoyama, Yukihiro; Ebata, Tomoki; Igami, Tsuyoshi; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Nagino, Masato

    2016-06-01

    Postoperative liver failure (PHLF) is one of the most common complications following major hepatectomy. The preoperative assessment of future liver remnant (FLR) function is critical to predict the incidence of PHLF. To determine the efficacy of the plasma clearance rate of indocyanine green clearance of FLR (ICGK-F) in predicting PHLF in cases of highly invasive hepatectomy with extrahepatic bile duct resection. Five hundred and eighty-five patients who underwent major hepatectomy with extrahepatic bile duct resection, from 2002 to 2014 in a single institution, were evaluated. Among them, 192 patients (33 %) had PHLF. The predictive value of ICGK-F for PHLF was determined and compared with other risk factors for PHLF. The incidence of PHLF was inversely proportional to the level of ICGK-F. With multivariate logistic regression analysis, ICGK-F, combined pancreatoduodenectomy, the operation time, and blood loss were identified as independent risk factors of PHLF. The risk of PHLF increased according to the decrement of ICGK-F (the odds ratio of ICGK-F for each decrement of 0.01 was 1.22; 95 % confidence interval 1.12-1.33; P bile duct resection. This criterion may be useful for highly invasive hepatectomy, such as that with extrahepatic bile duct resection.

  12. Detection of peritoneal dissemination with near-infrared fluorescence laparoscopic imaging using a liposomal formulation of a synthesized indocyanine green liposomal derivative.

    Science.gov (United States)

    Hoshino, Isamu; Maruyama, Tetsuro; Fujito, Hiromichi; Tamura, Yutaka; Suganami, Akiko; Hayashi, Hideki; Toyota, Taro; Akutsu, Yasunori; Murakami, Kentaro; Isozaki, Yuka; Akanuma, Naoki; Takeshita, Nobuyoshi; Toyozumi, Takeshi; Komatsu, Aki; Matsubara, Hisahiro

    2015-03-01

    Although conventional staging laparoscopy (SL) has improved the diagnostic accuracy of peritoneal dissemination, novel technology is needed to increase the sensitivity of SL. We herein describe a new imaging method employing near-infrared (NIR) fluorescence imaging using a liposomal synthesized indocyanine green (ICG) liposomal derivative, LP-ICG-C18. LP-ICG-C18 is a NIR-photoactivating probe in which an ICG fluorophore is covalently conjugated with a phospholipid moiety. Nude mice were intraperitoneally injected with gastric cancer cells. Twelve days later, the mice were given intravenous injections of LP-ICG-C18 at a dose of 0.15 mg/kg. A NIR imaging system was used to identify the disseminated tumors. The disseminated nodules in mice were detected without any difficulties. Disseminated tumor nodules were collected from mice with or without injections of liposomal formulation and were transferred into the swine peritoneal cavity. The nodules in the swine peritoneal cavity were clearly and promptly defined by the NIR imaging system. NIR-fluorescing liposomal probes can effectively target peritoneal disseminated tumors and can be easily detected by a NIR imaging system. These results warrant future clinical trials of our imaging system and may contribute to a more precise diagnosis and therapeutic approach for gastric cancer patients. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  13. Sentinel Node Mapping Using Indocyanine Green and Near-infrared Fluorescence Imaging Technology for Uterine Malignancies: Preliminary Experience With the Da Vinci Xi System.

    Science.gov (United States)

    Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico

    2016-01-01

    Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No

  14. Real-time navigation system for sentinel lymph node biopsy in breast cancer patients using projection mapping with indocyanine green fluorescence.

    Science.gov (United States)

    Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu

    2018-05-09

    Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.

  15. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    Science.gov (United States)

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  16. Smart human serum albumin-indocyanine green nanoparticles generated by programmed assembly for dual-modal imaging-guided cancer synergistic phototherapy.

    Science.gov (United States)

    Sheng, Zonghai; Hu, Dehong; Zheng, Mingbin; Zhao, Pengfei; Liu, Huilong; Gao, Duyang; Gong, Ping; Gao, Guanhui; Zhang, Pengfei; Ma, Yifan; Cai, Lintao

    2014-12-23

    Phototherapy, including photodynamic therapy (PDT) and photothermal therapy (PTT), is a light-activated local treatment modality that is under intensive preclinical and clinical investigations for cancer. To enhance the treatment efficiency of phototherapy and reduce the light-associated side effects, it is highly desirable to improve drug accumulation and precision guided phototherapy for efficient conversion of the absorbed light energy to reactive oxygen species (ROS) and local hyperthermia. In the present study, a programmed assembly strategy was developed for the preparation of human serum albumin (HSA)-indocyanine green (ICG) nanoparticles (HSA-ICG NPs) by intermolecular disulfide conjugations. This study indicated that HSA-ICG NPs had a high accumulation with tumor-to-normal tissue ratio of 36.12±5.12 at 24 h and a long-term retention with more than 7 days in 4T1 tumor-bearing mice, where the tumor and its margin, normal tissue were clearly identified via ICG-based in vivo near-infrared (NIR) fluorescence and photoacoustic dual-modal imaging and spectrum-resolved technology. Meanwhile, HSA-ICG NPs efficiently induced ROS and local hyperthermia simultaneously for synergetic PDT/PTT treatments under a single NIR laser irradiation. After an intravenous injection of HSA-ICG NPs followed by imaging-guided precision phototherapy (808 nm, 0.8 W/cm2 for 5 min), the tumor was completely suppressed, no tumor recurrence and treatments-induced toxicity were observed. The results suggest that HSA-ICG NPs generated by programmed assembly as smart theranostic nanoplatforms are highly potential for imaging-guided cancer phototherapy with PDT/PTT synergistic effects.

  17. The use of near-infrared fluorescence imaging in endocrine surgical procedures.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-06-01

    Near-infrared fluorescence imaging in endocrine surgery is a new, yet highly investigated area. It involves indocyanine green use as well as parathyroid autofluorescence. Several groups have described their technique and reported on the observed utility. However, there is no consensus on technical details. Furthermore, the correlation between intraoperative findings and postoperative outcomes is unclear. With this study, we aim to review the current literature on fluorescence imaging and share our insights on technical details. © 2017 Wiley Periodicals, Inc.

  18. In silico identification of a therapeutic target for photo-activated disinfection with indocyanine green: Modeling and virtual screening analysis of Arg-gingipain from Porphyromonas gingivalis.

    Science.gov (United States)

    Pourhajibagher, Maryam; Bahador, Abbas

    2017-06-01

    Porphyromonas gingivalis is a momentous bacterial etiological agent associated with periodontitis, peri-implantitis as well as endodontic infections. The potential advantage of Photo-activated disinfection (PAD) as a promising novel approach is the choice of a suitable target site, specific photosensitizer, and wavelength of light for delivery of the light from source to target. Since Arg-gingipain is a cysteine proteinase that is involved in the virulence of P. gingivalis, it was evaluated as a target site for PAD with indocyanine green (ICG) as a photosensitizer. In this study, we used a range of in silico strategies, bioinformatics tools, biological databases, and computer simulation molecular modeling to evaluate the capacity of Arg-gingipain. The predicted structure of Arg-gingipain indicated that it is located outside the cell and has nine domains and 17 ligands, including two calcium ions and three sodium ions with positive charges which can be a site of interaction for anionic ICG. Based on the results of this study, anionic ICG desires to bind and interact with residues of Arg-gingipain during PAD as a main site to enhance the yield of treatment of endo-periodontal lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A Near-Infrared Photothermal Effect-Responsive Drug Delivery System Based on Indocyanine Green and Doxorubicin-Loaded Polymeric Micelles Mediated by Reversible Diels-Alder Reaction.

    Science.gov (United States)

    Li, Hui; Li, Junjie; Ke, Wendong; Ge, Zhishen

    2015-10-01

    Near-infrared light (NIR) possesses great advantages for light-responsive controllable drug release, such as deep tissue penetration and low damage to healthy tissues. Herein, a NIR-responsive drug delivery system is developed based on a NIR dye, indocyanine green (ICG), and anticancer drug, doxorubicin (DOX)-loaded thermoresponsive block copolymer micelles, in which the drug release can be controlled via NIR irradiation. First, block copolymers, poly(oligo(ethylene glycol) methacrylate)-block-poly(furfuryl methacrylate) (POEGMA-b-PFMA), are synthesized by sequential reversible addition-fragmentation chain-transfer (RAFT) polymerization, followed by modification with N-octyl maleimide through Diels-Alder (DA) reaction to produce POEGMA-b-POMFMA. The self-assembly of POEGMA-b-POMFMA by nano-precipitation in aqueous solution affords the polymeric micelles which are used to simultaneously encapsulate ICG and DOX. Upon irradiation by NIR light (805 nm), the loaded DOX is released rapidly from the micelles due to partial retro DA reaction and local temperature increase-induced faster drug diffusion by the photothermal effect. Cytotoxicity evaluation and intracellular distribution observation demonstrate significant synergistic effects of NIR-triggered drug release, photothermal, and chemotherapy toward cancer cells under NIR irradiation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Intraoperative angiography provides objective assessment of skin perfusion in complex knee reconstruction.

    Science.gov (United States)

    Wyles, Cody C; Taunton, Michael J; Jacobson, Steven R; Tran, Nho V; Sierra, Rafael J; Trousdale, Robert T

    2015-01-01

    Wound necrosis is a potentially devastating complication of complex knee reconstruction. Laser-assisted indocyanine green angiography (LA-ICGA) is a technology that has been described in the plastic surgery literature to provide an objective assessment of skin perfusion in the operating room. This novel technology uses a plasma protein bound dye (ICG) and a camera unit that is calibrated to view the frequency emitted by the dye. The intention of this technology is to offer real-time visualization of blood flow to skin and soft tissue in a way that might help surgeons make decisions about closure or coverage of a surgical site based on blood flow, potentially avoiding soft tissue reconstruction while preventing skin necrosis or wound breakdown after primary closures, but its efficacy is untested in the setting of complex TKA. The purpose of this study was to evaluate perfusion borders and tension ischemia in a series of complex knee reconstructions to guide optimal wound management. Beginning in mid-2011, an LA-ICGA system was used to evaluate soft tissue viability in knee reconstruction procedures that were considered high risk for wound complications. Seven patients undergoing complex primary or revision TKA from 2011 to 2013 were included. These patients were chosen as a convenience sample of knee reconstruction procedures for which we obtained consultation with the plastic surgery service. The perfusion of skin and soft tissue coverage was evaluated intraoperatively for all patients with the LA-ICGA system, and the information was used to guide wound management. Followup was at a mean of 9 months (range, 6-17 months), no patients were lost to followup, and the main study endpoint was uneventful healing of the surgical incision. All seven closures went on to heal without necrosis. One patient, however, was subsequently revised for a deep periprosthetic infection 4 months after their knee reconstruction and underwent flap coverage at the time of that revision

  1. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green-Labeled Podoplanin Antibody.

    Science.gov (United States)

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.

  2. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    Science.gov (United States)

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  3. Flash fluorescence with indocyanine green videoangiography to identify the recipient artery for bypass with distal middle cerebral artery aneurysms: operative technique.

    Science.gov (United States)

    Rodríguez-Hernández, Ana; Lawton, Michael T

    2012-06-01

    Distal middle cerebral artery (MCA) aneurysms frequently have nonsaccular morphology that necessitates trapping and bypass. Bypasses can be difficult because efferent arteries lie deep in the opercular cleft and may not be easily identifiable. We introduce the "flash fluorescence" technique, which uses videoangiography with indocyanine green (ICG) dye to identify an appropriate recipient artery on the cortical surface for the bypass, enabling a more superficial and easier anastomosis. Flash fluorescence requires 3 steps: (1) temporary clip occlusion of the involved afferent artery; (2) videoangiography demonstrating fluorescence in uninvolved arteries on the cortical surface; and (3) removal of the temporary clip with flash fluorescence in the involved efferent arteries on the cortical surface, thereby identifying a recipient. Alternatively, temporary clips can occlude uninvolved arteries, and videoangiography will demonstrate initial fluorescence in efferent arteries during temporary occlusion and flash fluorescence in uninvolved arteries during reperfusion. From a consecutive series of 604 MCA aneurysms treated microsurgically, 22 (3.6%) were distal aneurysms and 11 required a bypass. The flash fluorescence technique was used in 3 patients to select the recipient artery for 2 superficial temporal artery-to-MCA bypasses and 1 MCA-MCA bypass. The correct recipient was selected in all cases. The flash fluorescence technique provides quick, reliable localization of an appropriate recipient artery for bypass when revascularization is needed for a distal MCA aneurysm. This technique eliminates the need for extensive dissection of the efferent artery and enables a superficial recipient site that makes the anastomosis safer, faster, and less demanding.

  4. A surgical navigation system for non-contact diffuse optical tomography and intraoperative cone-beam CT

    Science.gov (United States)

    Daly, Michael J.; Muhanna, Nidal; Chan, Harley; Wilson, Brian C.; Irish, Jonathan C.; Jaffray, David A.

    2014-02-01

    A freehand, non-contact diffuse optical tomography (DOT) system has been developed for multimodal imaging with intraoperative cone-beam CT (CBCT) during minimally-invasive cancer surgery. The DOT system is configured for near-infrared fluorescence imaging with indocyanine green (ICG) using a collimated 780 nm laser diode and a nearinfrared CCD camera (PCO Pixelfly USB). Depending on the intended surgical application, the camera is coupled to either a rigid 10 mm diameter endoscope (Karl Storz) or a 25 mm focal length lens (Edmund Optics). A prototype flatpanel CBCT C-Arm (Siemens Healthcare) acquires low-dose 3D images with sub-mm spatial resolution. A 3D mesh is extracted from CBCT for finite-element DOT implementation in NIRFAST (Dartmouth College), with the capability for soft/hard imaging priors (e.g., segmented lymph nodes). A stereoscopic optical camera (NDI Polaris) provides real-time 6D localization of reflective spheres mounted to the laser and camera. Camera calibration combined with tracking data is used to estimate intrinsic (focal length, principal point, non-linear distortion) and extrinsic (translation, rotation) lens parameters. Source/detector boundary data is computed from the tracked laser/camera positions using radiometry models. Target registration errors (TRE) between real and projected boundary points are ~1-2 mm for typical acquisition geometries. Pre-clinical studies using tissue phantoms are presented to characterize 3D imaging performance. This translational research system is under investigation for clinical applications in head-and-neck surgery including oral cavity tumour resection, lymph node mapping, and free-flap perforator assessment.

  5. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis.

    Science.gov (United States)

    Pind, Marie-Louise L; Bendtsen, Flemming; Kallemose, Thomas; Møller, Søren

    2016-08-01

    Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands expert skills of the staff.In the present study, we aimed to investigate the relationship between the constant infusion indocyanine green (ICG) clearance, the calculated ICG retention test after 15 min (ICG-r15), and HVPG in patients with different severity of cirrhosis for validation of ICG-r15 as a noninvasive predictor of portal hypertension. A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. Assessment of the diagnostic performance of ICG clearance and ICG-r15 as predictors of HVPG above 10 mmHg was performed by receiver operating characteristic curve analyses.The ICG clearance and ICG-r15 performed well in all three Child classes, with the most significant results among Child class A patients [area under the receiver operating characteristic (AUROC)=0.832] and less significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15 may be suitable as a screening tool for the identification of patients for endoscopy and measurement of HVPG.Further validation of ICG-r15 together with other predictors of portal hypertension and its clinical use is encouraged.

  6. Pilot Assessment of the Repeatability of Indocyanine Green Fluorescence Imaging and Correlation with Traditional Foot Perfusion Assessments.

    Science.gov (United States)

    Venermo, M; Settembre, N; Albäck, A; Vikatmaa, P; Aho, P-S; Lepäntalo, M; Inoue, Y; Terasaki, H

    2016-10-01

    Ankle brachial index (ABI), toe pressures (TP), and transcutaneous oxygen pressure (TcPO 2 ) are traditionally used in the assessment of critical limb ischemia (CLI). Indocyanine green (ICG) fluorescence imaging can be used to evaluate local circulation in the foot and to evaluate the severity of ischemia. This prospective study analyzed the suitability of a fluorescence imaging system (photodynamic eye [PDE]) in CLI. Forty-one patients with CLI were included. Of the patients, 66% had diabetes and there was an ischemic tissue lesion in 70% of the limbs. ABI, toe pressures, TcPO 2 and ICG-fluorescence imaging (ICG-FI) were measured in each leg. To study the repeatability of the ICG-FI, each patient underwent the study twice. After the procedure, foot circulation was measured using a time-intensity curve, where T1/2 (the time needed to achieve half of the maximum fluorescence intensity) and PDE10 (increase of the intensity during the first 10 s) were determined. A time-intensity curve was plotted using the same areas as for the TcPO 2 probes (n=123). The mean ABI was 0.43, TP 21 mmHg, TcPO 2 23 mmHg, T1/2 38 s, and PDE10 19 AU. Time-intensity curves were repeatable. In a Bland-Altman scatter plot, the 95% limits of agreement of PDE10 was 9.9 AU and the corresponding value of T1/2 was 14 s. Correlation between ABI and TP was significant (R=.73, p<.001), and it was weaker in diabetic patients (R=.47, p=.048) compared with non-diabetic patients (R=.89, p=.002). Correlations between ABI and TcPO 2 and TP and TcPO 2 were weak (R=.37, p=.05 and R=.43, p=.037, respectively). Correlation between TcPO 2 and PDE10 was strong in diabetic patients (R=.70, p=.003). According to this pilot study, ICG-FI with PDE can be used in the assessment of blood supply in the ischemic foot. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Peptide-Based Optical uPAR Imaging for Surgery

    DEFF Research Database (Denmark)

    Juhl, Karina; Christensen, Anders; Persson, Morten

    2016-01-01

    Near infrared intra-operative optical imaging is an emerging technique with clear implications for improved cancer surgery by enabling a more distinct delineation of the tumor margins during resection. This modality has the potential to increase the number of patients having a curative radical...... tumor resection. In the present study, a new uPAR-targeted fluorescent probe was developed and the in vivo applicability was evaluated in a human xenograft mouse model. Most human carcinomas express high level of uPAR in the tumor-stromal interface of invasive lesions and uPAR is therefore considered...... an ideal target for intra-operative imaging. Conjugation of the flourophor indocyanine green (ICG) to the uPAR agonist (AE105) provides an optical imaging ligand with sufficiently high receptor affinity to allow for a specific receptor targeting in vivo. For in vivo testing, human glioblastoma xenograft...

  8. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    Science.gov (United States)

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  9. Fluorescent Imaging With Indocyanine Green During Laparoscopic Cholecystectomy in Patients at Increased Risk of Bile Duct Injury

    NARCIS (Netherlands)

    Ankersmit, M.; Dam, D.A. van; Rijswijk, A.S. van; Tuynman, J.B.; Meijerink, W.J.H.J.

    2017-01-01

    BACKGROUND: Although rare, injury to the common bile duct (CBD) during laparoscopic cholecystectomy (LC) can be reduced by better intraoperative visualization of the cystic duct (CD) and CBD. The aim of this study was to establish the efficacy of early visualization of the CD and the added value of

  10. Host-guest chemistry of dendrimer-drug complexes: 7. Formation of stable inclusions between acetylated dendrimers and drugs bearing multiple charges.

    Science.gov (United States)

    Fang, Min; Zhang, Jiahai; Wu, Qinglin; Xu, Tongwen; Cheng, Yiyun

    2012-03-15

    Drug molecules bearing multiple charges usually form precipitates with cationic dendrimers, which presents a challenge during the preparation of dendrimer inclusions for these drugs. In the present study, fully acetylated polyamidoamine (PAMAM) dendrimers were proposed as stable vehicles for drug molecules bearing two negative charges such as Congo red and indocyanine green. NMR techniques including (1)H NMR and (1)H-(1)H NOESY were used to characterize the host-guest chemistry of acetylated dendrimer and these guest molecules. The cationic PAMAM dendrimer was found to form a precipitate with Congo red and indocyanine green, but the acetylated one avoided the formation of cross-linking structures in aqueous solutions. NOESY studies revealed the encapsulation of Congo red and indocyanine green within the interior cavities of PAMAM dendrimers at mild acidic conditions and acetylated dendrimers show much stronger ability to encapsulate the guest molecules than cationic ones. Also, UV-vis-NIR studies suggest that acetylated dendrimers significantly improve the photostability of indocyanine green and prevent the formation of indocyanine green J-aggregates in aqueous solutions. The present study provides a new insight into dendrimer-based host-guest systems, especially for those guest molecules bearing multiple charges. © 2012 American Chemical Society

  11. Intraoperative electrocorticography

    Directory of Open Access Journals (Sweden)

    Gabriela Alcaraz

    2017-01-01

    Full Text Available Intraoperative electrocorticography (ECoG is the recording of electrophysiological activity from electrodes placed directly on the exposed surface of brain, during surgery for epilepsy and tumor resection. The ECoG is helpful in defining the seizure onset and spread within the cortical surface and delineation of the interface between epileptogenic zones and functional cortex substance of the brain. Intraoperative ECoG is an invasive procedure, it is performed during surgery mostly commonly during awake craniotomy but at times during general anaesthesia. As most anesthetic agents will affect ECoG, they should be minimized or stopped prior to any recording. Activation of intraoperative epileptiform activity may also be required if there are no spontaneous discharges. The appropriate management of the anesthetic during the time of ECoG is critical for its success. There are limitations and some controversies to all the uses of intraoperative ECoG, thus each center will set their own indications, criteria, and protocols.

  12. Comparison between the indocyanine green fluorescence and blue dye methods for sentinel lymph node biopsy using novel fluorescence image-guided resection equipment in different types of hospitals.

    Science.gov (United States)

    He, Kunshan; Chi, Chongwei; Kou, Deqiang; Huang, Wenhe; Wu, Jundong; Wang, Yabing; He, Lifang; Ye, Jinzuo; Mao, Yamin; Zhang, Guo-Jun; Wang, Jiandong; Tian, Jie

    2016-12-01

    Sentinel lymph node biopsy (SLNB) has become a standard of care to detect axillary lymph metastasis in early-stage breast cancer patients with clinically negative axillary lymph nodes. Current SLNB detection modalities comprising a blue dye, a radioactive tracer, or a combination of both have advantages as well as disadvantages. Thus, near-infrared fluorescence imaging using indocyanine green (ICG) has recently been regarded as a novel method that has generated interest for SLNB around the world. However, the lack of appropriate fluorescence imaging systems has hindered further research and wide application of this method. Therefore, we developed novel fluorescence image-guided resection equipment (FIRE) to detect sentinel lymph nodes (SLNs). Moreover, to compare the ICG fluorescence imaging method with the blue dye method and to explore the universal feasibility of the former, a different type of hospital study was conducted. Ninety-nine eligible patients participated in the study at 3 different types of hospitals. After subcutaneous ICG allergy testing, all the patients were subcutaneously injected with methylene blue and ICG into the subareolar area. Consequently, 276 SLNs (range 1-7) were identified in 98 subjects (detection rate: 99%) by using the ICG fluorescence imaging method. In contrast, the blue dye method only identified 202 SLNs (range 1-7) in 91 subjects (detection rate: 91.92%). Besides, the results of the fluorescence imaging method were similar in the 3 hospitals. Our findings indicate the universal feasibility of the ICG fluorescence imaging method for SLNB using the fluorescence image-guided resection equipment in early breast cancer detection. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Cheung, Tan To; Chan, See Ching; Chok, Kenneth S H; Chan, Albert C Y; Yu, Wan Ching; Poon, Ronnie T P; Lo, Chung Mau; Fan, Sheung Tat

    2012-06-01

    The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly-developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON(®), one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16XICGR15(L)+2.73. The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.

  14. Intraoperative high-field magnetic resonance imaging, multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas.

    Science.gov (United States)

    Li, Fang-Ye; Chen, Xiao-Lei; Xu, Bai-Nan

    2016-09-01

    To determine the beneficial effects of intraoperative high-field magnetic resonance imaging (MRI), multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas. Twelve patients with 13 supratentorial cavernomas were prospectively enrolled and operated while using a 1.5 T intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. All cavernomas were deeply located in subcortical areas or involved critical areas. Intraoperative high-field MRIs were obtained for the intraoperative "visualization" of surrounding eloquent structures, "brain shift" corrections, and navigational plan updates. All cavernomas were successfully resected with guidance from intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. In 5 cases with supratentorial cavernomas, intraoperative "brain shift" severely deterred locating of the lesions; however, intraoperative MRI facilitated precise locating of these lesions. During long-term (>3 months) follow-up, some or all presenting signs and symptoms improved or resolved in 4 cases, but were unchanged in 7 patients. Intraoperative high-field MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring are helpful in surgeries for the treatment of small deeply seated subcortical cavernomas.

  15. [Intraoperative multidimensional visualization].

    Science.gov (United States)

    Sperling, J; Kauffels, A; Grade, M; Alves, F; Kühn, P; Ghadimi, B M

    2016-12-01

    Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.

  16. Introducing navigation during melanoma-related sentinel lymph node procedures in the head-and-neck region.

    Science.gov (United States)

    KleinJan, Gijs H; Karakullukçu, Baris; Klop, W Martin C; Engelen, Thijs; van den Berg, Nynke S; van Leeuwen, Fijs W B

    2017-08-17

    Intraoperative sentinel node (SN) identification in patients with head-and-neck malignancies can be challenging due to unexpected drainage patterns and anatomical complexity. Here, intraoperative navigation-based guidance technologies may provide outcome. In this study, gamma camera-based freehandSPECT was evaluated in combination with the hybrid tracer ICG- 99m Tc-nanocolloid. Eight patients with melanoma located in the head-and-neck area were included. Indocyanine green (ICG)- 99m Tc-nanocolloid was injected preoperatively, whereafter lymphoscintigraphy and SPECT/CT imaging were performed in order to define the location of the SN(s). FreehandSPECT scans were generated in the operation room using a portable gamma camera. For lesion localization during surgery, freehandSPECT scans were projected in an augmented reality video-view that was used to spatially position a gamma-ray detection probe. Intraoperative fluorescence imaging was used to confirm the accuracy of the navigation-based approach and identify the exact location of the SNs. Preoperatively, 15 SNs were identified, of which 14 were identified using freehandSPECT. Navigation towards these nodes using the freehandSPECT approach was successful in 13 nodes. Fluorescence imaging provided optical confirmation of the navigation accuracy in all patients. In addition, fluorescence imaging allowed for the identification of (clustered) SNs that could not be identified based on navigation alone. The use of gamma camera-based freehandSPECT aids intraoperative lesion identification and, with that, supports the transition from pre- to intraoperative imaging via augmented reality display and directional guidance.

  17. Solvent effect on indocyanine dyes: A computational approach

    International Nuclear Information System (INIS)

    Bertolino, Chiara A.; Ferrari, Anna M.; Barolo, Claudia; Viscardi, Guido; Caputo, Giuseppe; Coluccia, Salvatore

    2006-01-01

    The solvatochromic behaviour of a series of indocyanine dyes (Dyes I-VIII) was investigated by quantum chemical calculations. The effect of the polymethine chain length and of the indolenine structure has been satisfactorily reproduced by semiempirical Pariser-Parr-Pople (PPP) calculations. The solvatochromism of 3,3,3',3'-tetramethyl-N,N'-diethylindocarbocyanine iodide (Dye I) has been deeply investigated within the ab initio time-dependent density functional theory (TD-DFT) approach. Dye I undergoes non-polar solvation and a linear correlation has been individuated between absorption shifts and refractive index. Computed absorption λ max and oscillator strengths obtained by TD-DFT are in good agreement with the experimental data

  18. Intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Dobelbower Junior, R.R.

    1987-01-01

    A briefly history of intraoperative radiotherapy is presented. The equipment used is described and the treatment with superficial X-ray beams, orthovoltage X-ray beams and megavoltage electron beams are discussed. The effect on normal tissues and the clinical use of intraoperative radiotherapy in several Kind of cancer is studied. (M.A.C.) [pt

  19. Image navigation as a means to expand the boundaries of fluorescence-guided surgery.

    Science.gov (United States)

    Brouwer, Oscar R; Buckle, Tessa; Bunschoten, Anton; Kuil, Joeri; Vahrmeijer, Alexander L; Wendler, Thomas; Valdés-Olmos, Renato A; van der Poel, Henk G; van Leeuwen, Fijs W B

    2012-05-21

    Hybrid tracers that are both radioactive and fluorescent help extend the use of fluorescence-guided surgery to deeper structures. Such hybrid tracers facilitate preoperative surgical planning using (3D) scintigraphic images and enable synchronous intraoperative radio- and fluorescence guidance. Nevertheless, we previously found that improved orientation during laparoscopic surgery remains desirable. Here we illustrate how intraoperative navigation based on optical tracking of a fluorescence endoscope may help further improve the accuracy of hybrid surgical guidance. After feeding SPECT/CT images with an optical fiducial as a reference target to the navigation system, optical tracking could be used to position the tip of the fluorescence endoscope relative to the preoperative 3D imaging data. This hybrid navigation approach allowed us to accurately identify marker seeds in a phantom setup. The multispectral nature of the fluorescence endoscope enabled stepwise visualization of the two clinically approved fluorescent dyes, fluorescein and indocyanine green. In addition, the approach was used to navigate toward the prostate in a patient undergoing robot-assisted prostatectomy. Navigation of the tracked fluorescence endoscope toward the target identified on SPECT/CT resulted in real-time gradual visualization of the fluorescent signal in the prostate, thus providing an intraoperative confirmation of the navigation accuracy.

  20. Benchtop and animal validation of a portable fluorescence microscopic imaging system for potential use in cholecystectomy

    Science.gov (United States)

    Ye, Jian; Liu, Guanghui; Liu, Peng; Zhang, Shiwu; Shao, Pengfei; Smith, Zachary J.; Liu, Chenhai; Xu, Ronald X.

    2018-02-01

    We propose a portable fluorescence microscopic imaging system (PFMS) for intraoperative display of biliary structure and prevention of iatrogenic injuries during cholecystectomy. The system consists of a light source module, a camera module, and a Raspberry Pi computer with an LCD. Indocyanine green (ICG) is used as a fluorescent contrast agent for experimental validation of the system. Fluorescence intensities of the ICG aqueous solution at different concentration levels are acquired by our PFMS and compared with those of a commercial Xenogen IVIS system. We study the fluorescence detection depth by superposing different thicknesses of chicken breast on an ICG-loaded agar phantom. We verify the technical feasibility for identifying potential iatrogenic injury in cholecystectomy using a rat model in vivo. The proposed PFMS system is portable, inexpensive, and suitable for deployment in resource-limited settings.

  1. Complex microcirculation patterns detected by confocal indocyanine green angiography predict time to growth of small choroidal melanocytic tumors: MuSIC Report II.

    Science.gov (United States)

    Mueller, Arthur J; Freeman, William R; Schaller, Ulrich C; Kampik, Anselm; Folberg, Robert

    2002-12-01

    Multiple independent laboratories have confirmed the histologic observation that some tumor microcirculation patterns (MCPs) in uveal melanomas are associated strongly with death resulting from metastatic disease. Because these patterns are imageable with confocal indocyanine green angiography (ICG), we designed a prospective study to evaluate whether these angiographically detectable MCPs predict time to tumor growth. Observational case series, prospective, non-randomized. Ninety-eight patients with unilateral, small, choroidal melanocytic tumors. The following information and tumor characteristics were recorded for each patient: demographic parameters, best-corrected visual acuity, intraocular pressure, related visual symptoms, location and dimension of tumor, pigmentation, orange pigment, drusen, tumor-associated hemorrhage, subretinal fluid, and confocal ICG angiographically determined microcirculation patterns-silent (avascularity), normal (preexisting normal choroidal vessels within the tumor), straight vessels, parallel without and with cross-linking, arcs without and with branching, loops, and networks. Time to growth of the tumor, with growth defined as an increase in the maximal apical tumor height of 0.5 mm measured by standardized A-scan ultrasonography, photographic documentation of an increase of the largest basal diameter of at least 1.5 mm, advancement of one tumor border of at least 0.75 mm, or a combination thereof. Twenty-eight of the 98 tumors in this study (29%) met the predetermined criteria for tumor growth. The median time to growth was 127 days (range, 51-625 days). The following tumor characteristics were significantly associated with time to tumor growth: flashes (P = 0.0224), orange pigment (P = 0.012), subretinal fluid (P < 0.001), maximum basal tumor diameter at initial examination (P = 0.015), maximum apical tumor height (P < 0.001), parallel with cross-linking MCP (P < 0.001), arcs with branching MCP (P = 0.006), loops (P < 0

  2. [A Case of Gastric Cancer with Splenic Artery Aneurysm, Intraoperative ICG Fluorography Is Useful in Evaluating the Blood Flow of Stomach and Spleen].

    Science.gov (United States)

    Usui, Kenji; Sakamoto, Kaoru; Akabane, Kentaro; Hayasaka, Kazuki; Mizuki, Toru; Yagi, Yutaka; Shirahata, Yasuhiro; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kameyama, Hitoshi; Suzuki, Satoshi; Saito, Kiyohiro; Wakai, Toshifumi

    2017-11-01

    An 81-year-oldwoman with advancedgastric cancer was referredto our hospital. Preoperative contrast-enhancedCT revealeda roundcalcification of the splenic hilum with 15mm in diameter as a splenic artery aneurysm. She underwent transcatheter arterial embolization(TAE)for the splenic artery aneurysm. Celiac artery angiography showedcollateral arterial network of the spleen from left gastric artery. Surgery for the gastric cancer was performed1 4 days after TAE. We cut the right gastric andbilateral epigastric arteries. After the left gastric artery clamping, we performedintraoperative indocyanine green(ICG)fluorography. ICG fluorography confirmedthat the bloodflow of the upper thirdof the stomach andspleen were maintained. We safely performed distal gastrectomy, and the postoperative course was uneventful.

  3. Association between pretreatment retention rate of indocyanine green 15 min after administration and life prognosis in patients with HCC treated by proton beam therapy

    International Nuclear Information System (INIS)

    Mizumoto, Masashi; Oshiro, Yoshiko; Okumura, Toshiyuki; Fukuda, Kuniaki; Fukumitsu, Nobuyoshi; Abei, Masato; Ishikawa, Hitoshi; Ohnishi, Kayoko; Numajiri, Haruko; Tsuboi, Koji; Sakurai, Hideyuki

    2014-01-01

    Purpose: The Child-Pugh score is often used to judge the outcome of radiotherapy for hepatocellular carcinoma (HCC). The retention rate of indocyanine green 15 min after administration (ICG R15) can also be used to predict prognosis after liver resection. We evaluated the utility of ICG R15 for prediction of outcomes after proton beam therapy (PBT) for HCC. Methods and materials: A retrospective evaluation was performed in 250 patients who received PBT between 2002 and 2007. The patients (178 males and 72 females) had a median age of 71 years (range: 43–88). Child-Pugh categories were A (score 5–6), B (7–9), and C (10–15) in 197, 51, and 2 patients, respectively. ICG scores were 0–<10, 10–<20, 20–<30, 30–<40 and ⩾40 in 27, 99, 59, 28 and 37 patients, respectively; including 26, 92, 45, 16 and 18 Child-Pugh A patients and 1, 8, 14, 11, and 17 Child-Pugh B patients, respectively. Survival times from the start of PBT were compared between Child-Pugh A and B patients, and among each ICG group. Results: The median survival times were 61 months (95% CI: 50–72 months) in all patients, and 64 and 20 months in Child-Pugh A and B patients, respectively (p = 0.001), The 3-year survival rates were 72%, 72%, 75%, 63%, and 26% in patients with ICG scores of 0–<10, 10–<20, 20–<30, 30–<40, and ⩾40 (p = 0.001); 70%, 75%, 77%, 65%, and 38% in these respective groups in Child-Pugh A patients (p = 0.02); and 100%, 57%, 67%, 36%, and 14% in Child-Pugh B patients (p = 0.173, not significant). Multivariate analysis showed that low ICG R15 and the absence of portal vein tumor thrombus were associated with good survival. Conclusions: Pretreatment ICG R15 is a useful prognostic factor for prediction of outcome of PBT in HCC patients, especially in those with Child-Pugh A liver function

  4. Correlation between HBsAg, prothrombin time activity, and indocyanine green retention rate at 15 minutes in patients with HBeAg-positive chronic HBV infection

    Directory of Open Access Journals (Sweden)

    FAN Wenhai

    2016-11-01

    Full Text Available ObjectiveTo investigate the correlation between HBsAg, prothrombin time activity (PTA, and indocyanine green retention rate at 15 minutes (ICG R15 in patients with HBeAg-positive chronic HBV infection. MethodsA total of 92 patients with HBeAg-positive chronic HBV infection who were admitted to The First Hospital of Lanzhou University from December 2015 to April 2016 were enrolled and divided into chronic hepatitis B (CHB group (24 patients, compensated liver cirrhosis group (38 patients, and decompensated liver cirrhosis group (30 patients. Serum HBsAg quantitation, PTA test, and liver reserve function test (ICG R15 were performed for all patients. The chi-square test was used for comparison of categorical data between groups, an analysis of variance was used for comparison of continuous data between multiple groups, and a Pearson correlation analysis was also performed. ResultsThere were significant differences between the three groups in serum HBsAg quantitation (3.82±0.43 log10IU/ml vs 2.88±0.36 log10IU/ml vs 2.60±0.27 log10IU/ml, F=25.19, P<0.001, ICG R15 (7.51%±3.10% vs 9.57%±8.18% vs 24.13%±14.28%, F=24.00, P=0.001, and PTA (8100%±1762% vs 83.08%±9.64% vs 62.32%±16.90%, F=13.42, P=0.009. The correlation analysis showed that PTA was negatively correlated with ICG R15 in all three groups (r=-0.948, -0.602, and -0.735, all P<0.01. In the compensated liver cirrhosis group and decompensated liver cirrhosis group, HBsAg was positively correlated with PTA (r=0.410 and 0.473, both P<0.05 and negatively correlated with ICG R15 (r=-0.427 and -0.768, P<0.01. ConclusionIn HBeAg positive patients, there are certain correlations between HBsAg, PTA, and ICG R15, which, to a certain degree, reflects the liver reserve function in patients with chronic HBV infection.

  5. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  6. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  7. Brain tumors in eloquent areas: A European multicenter survey of intraoperative mapping techniques, intraoperative seizures occurrence, and antiepileptic drug prophylaxis.

    Science.gov (United States)

    Spena, Giannantonio; Schucht, Philippe; Seidel, Kathleen; Rutten, Geert-Jan; Freyschlag, Christian Franz; D'Agata, Federico; Costi, Emanule; Zappa, Francesca; Fontanella, Marco; Fontaine, Denys; Almairac, Fabien; Cavallo, Michele; De Bonis, Pasquale; Conesa, Gerardo; Foroglou, Nicholas; Gil-Robles, Santiago; Mandonnet, Emanuel; Martino, Juan; Picht, Thomas; Viegas, Catarina; Wager, Michel; Pallud, Johan

    2017-04-01

    Intraoperative mapping and monitoring techniques for eloquent area tumors are routinely used world wide. Very few data are available regarding mapping and monitoring methods and preferences, intraoperative seizures occurrence and perioperative antiepileptic drug management. A questionnaire was sent to 20 European centers with experience in intraoperative mapping or neurophysiological monitoring for the treatment of eloquent area tumors. Fifteen centers returned the completed questionnaires. Data was available on 2098 patients. 863 patients (41.1%) were operated on through awake surgery and intraoperative mapping, while 1235 patients (58.8%) received asleep surgery and intraoperative electrophysiological monitoring or mapping. There was great heterogeneity between centers with some totally AW oriented (up to 100%) and other almost totally ASL oriented (up to 92%) (31% SD). For awake surgery, 79.9% centers preferred an asleep-awake-asleep anesthesia protocol. Only 53.3% of the centers used ECoG or transcutaneous EEG. The incidence of intraoperative seizures varied significantly between centers, ranging from 2.5% to 54% (p mapping technique and the risk of intraoperative seizures. Moreover, history of preoperative seizures can significantly increase the risk of intraoperative seizures (p mapping and monitoring protocols and the management of peri- and intraoperative seizures. This data can help identify specific aspects that need to be investigated in prospective and controlled studies.

  8. Quantitative fluorescence angiography for neurosurgical interventions.

    Science.gov (United States)

    Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute

    2013-06-01

    Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.

  9. [Selective intraoperative cholangiography in laparoscopic cholecystectomy].

    Science.gov (United States)

    Pickuth, D; Leutloff, U

    1995-01-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments; however, it is controversial. We have developed a new diagnostic strategy for the detection of bile duct stones. The concept is based on an ultrasound examination and on screening for the presence of six risk indicators of choledocholithiasis. A total of 120 patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of these six risk indicators: history of jaundice, history of pancreatitis, hyperbilirubinemia, hyperamylasemia, dilated bile duct, and unclear ultrasound findings. The sensitivity of ultrasound and intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. Twenty percent of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (P concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that routine use of intraoperative cholangiography is not necessary.

  10. Intraoperative radiotherapy in breast cancer: literature review

    International Nuclear Information System (INIS)

    Alfaro Hidalgo, Sabrina A.

    2013-01-01

    A literature review was performed on intraoperative radiotherapy of breast cancer. The strength and attractiveness is established of techniques of partial irradiation in the treatment of breast cancer. The benefit is originated to restrict the area immediate of radiotherapy to the tumor bed or quadrant index and identifying the benefit of being applied during the radiotherapy while surgical lumpectomy. The impact of local recurrence has been established using intraoperative radiotherapy. The advantages of intraoperative radiotherapy was compared in the management of the conservative surgery in early stages of breast cancer with external radiotherapy. Different methods of intraoperative radiotherapy have been compared and individual impact on local recurrence ranges. Intraoperative radiotherapy has had many advantages: radiobiological, technical, clinical, psychological and economical in the handling of conservative surgery in early stages of breast cancer, compared with external radiotherapy [es

  11. Intraoperative ultrasound in colorectal surgery.

    Science.gov (United States)

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  12. The use of intraoperative computed tomography navigation in pituitary surgery promises a better intraoperative orientation in special cases

    Directory of Open Access Journals (Sweden)

    Stefan Linsler

    2016-01-01

    Full Text Available Objective: The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT and magnetic resonance imaging (MRI. Here, we report our initial experience of real-time intraoperative CT-guided navigation surgery for pituitary tumors in childhood. Materials and Methods: We report the case of a 15-year-old girl with a huge growth hormone-secreting pituitary adenoma with supra- and perisellar extension. Furthermore, the skull base was infiltrated. In this case, we performed an endonasal transsphenoidal approach for debulking the adenoma and for chiasma decompression. We used an MRI neuronavigation (Medtronic Stealth Air System which was registered via intraoperative CT scan (Siemens CT Somatom. Preexisting MRI studies (navigation protocol were fused with the intraoperative CT scans to enable three-dimensional navigation based on MR and CT imaging data. Intraoperatively, we did a further CT scan for resection control. Results: The intraoperative accuracy of the neuronavigation was excellent. There was an adjustment of <1 mm. The navigation was very helpful for orientation on the destroyed skull base in the sphenoid sinus. After opening the sellar region and tumor debulking, we did a CT scan for resection control because the extent of resection was not credible evaluable in this huge infiltrating adenoma. Thereby, we were able to demonstrate a sufficient decompression of the chiasma and complete resection of the medial part of the adenoma in the intraoperative CT images. Conclusions: The use of intraoperative CT/MRI-guided neuronavigation for transsphenoidal surgery is a time-effective, safe, and technically beneficial technique for special cases.

  13. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  14. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  15. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  16. Intraoperative transfusion practices in Europe

    DEFF Research Database (Denmark)

    Meier, J; Filipescu, D; Kozek-Langenecker, S

    2016-01-01

    BACKGROUND: Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (p......RBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. METHODS: We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month...... period in 2013. RESULTS: The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone...

  17. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  19. Intraoperative radiotherapy in primary rectal cancer; Intraoperative Radiotherapie des primaeren Rektumkarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Mund, Christian

    2013-06-17

    According to the results of several studies intraoperative radiotherapy seems to influence local control for primary rectal cancer in UICC-Stage II / III positively, though recommendations in therapy cannot be given as studies of high evidence level do not exist. As IORT is rarely available and makes patient recruitment difficult, prospective randomised trials have not been carried out yet. This emphasizes the importance of non-randomised trials for an evaluation of IORT. A comparison of 21 patients with locally advanced rectal cancer who had been treated with intraoperative radiation therapy and 21 similar cases without an application of IORT could not show any significant improvements in prognosis (recurrences, metastases and disease-specific survival). Nevertheless the employment of intraoperative radiation showed a trend in improvement of local control. This hast been shown by several other studies before. Thus the application of IORT in patients with locally advanced rectal cancer is considered a useful part in multimodal treatment and should further be evaluated in specialized centres. In case-control studies 1:1-matching leads to a good comparability of groups and renders conclusions of high internal validity possible. To gain a sufficient power, this type of trials should however primarily be carried out by centres with a high number of cases.

  20. Fully integrated high-speed intravascular optical coherence tomography/near-infrared fluorescence structural/molecular imaging in vivo using a clinically available near-infrared fluorescence-emitting indocyanine green to detect inflamed lipid-rich atheromata in coronary-sized vessels.

    Science.gov (United States)

    Lee, Sunki; Lee, Min Woo; Cho, Han Saem; Song, Joon Woo; Nam, Hyeong Soo; Oh, Dong Joo; Park, Kyeongsoon; Oh, Wang-Yuhl; Yoo, Hongki; Kim, Jin Won

    2014-08-01

    Lipid-rich inflamed coronary plaques are prone to rupture. The purpose of this study was to assess lipid-rich inflamed plaques in vivo using fully integrated high-speed optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) molecular imaging with a Food and Drug Administration-approved indocyanine green (ICG). An integrated high-speed intravascular OCT/NIRF imaging catheter and a dual-modal OCT/NIRF system were constructed based on a clinical OCT platform. For imaging lipid-rich inflamed plaques, the Food and Drug Administration-approved NIRF-emitting ICG (2.25 mg/kg) or saline was injected intravenously into rabbit models with experimental atheromata induced by balloon injury and 12- to 14-week high-cholesterol diets. Twenty minutes after injection, in vivo OCT/NIRF imaging of the infrarenal aorta and iliac arteries was acquired only under contrast flushing through catheter (pullback speed up to ≤20 mm/s). NIRF signals were strongly detected in the OCT-visualized atheromata of the ICG-injected rabbits. The in vivo NIRF target-to-background ratio was significantly larger in the ICG-injected rabbits than in the saline-injected controls (Pfluorescence reflectance imaging, which correlated well with the in vivo target-to-background ratios (Pfluorescence microscopy, and histopathology also corroborated the in vivo imaging findings. Integrated OCT/NIRF structural/molecular imaging with a Food and Drug Administration -approved ICG accurately identified lipid-rich inflamed atheromata in coronary-sized vessels. This highly translatable dual-modal imaging approach could enhance our capabilities to detect high-risk coronary plaques. © 2014 American Heart Association, Inc.

  1. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared fluorescent imaging.

    Science.gov (United States)

    Rangaraj, Aravind T; Ghanta, Ravi K; Umakanthan, Ramanan; Soltesz, Edward G; Laurence, Rita G; Fox, John; Cohn, Lawrence H; Bolman, R M; Frangioni, John V; Chen, Frederick Y

    2008-01-01

    Homogeneous delivery of cardioplegia is essential for myocardial protection during cardiac surgery. Presently, there exist no established methods to quantitatively assess cardioplegia distribution intraoperatively and determine when retrograde cardioplegia is required. In this study, we evaluate the feasibility of near infrared (NIR) imaging for real-time visualization of cardioplegia distribution in a porcine model. A portable, intraoperative, real-time NIR imaging system was utilized. NIR fluorescent cardioplegia solution was developed by incorporating indocyanine green (ICG) into crystalloid cardioplegia solution. Real-time NIR imaging was performed while the fluorescent cardioplegia solution was infused via the retrograde route in five ex vivo normal porcine hearts and in five ex vivo porcine hearts status post left anterior descending (LAD) coronary artery ligation. Horizontal cross-sections of the hearts were obtained at proximal, middle, and distal LAD levels. Videodensitometry was performed to quantify distribution of fluorophore content. The progressive distribution of cardioplegia was clearly visualized with NIR imaging. Complete visualization of retrograde distribution occurred within 4 minutes of infusion. Videodensitometry revealed retrograde cardioplegia, primarily distributed to the left ventricle (LV) and anterior septum. In hearts with LAD ligation, antegrade cardioplegia did not distribute to the anterior LV. This deficiency was compensated for with retrograde cardioplegia supplementation. Incorporation of ICG into cardioplegia allows real-time visualization of cardioplegia delivery via NIR imaging. This technology may prove useful in guiding intraoperative decisions pertaining to when retrograde cardioplegia is mandated.

  2. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    Science.gov (United States)

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  3. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  4. Dry Eye Following Phacoemulsification Surgery and its Relation to Associated Intraoperative Risk Factors.

    Science.gov (United States)

    Sahu, P K; Das, G K; Malik, Aman; Biakthangi, Laura

    2015-01-01

    The purpose was to study dry eye following phacoemulsification surgery and analyze its relation to associated intra-operative risk factors. A prospective observational study was carried out on 100 eyes of 100 patients without preoperative dry eye. Schirmer's Test I, tear meniscus height, tear break-up time, and lissamine green staining of cornea and conjunctiva were performed preoperatively and at 5 days, 10 days, 1-month, and 2 months after phacoemulsification surgery, along with the assessment of subjective symptoms, using the dry eye questionnaire. The correlations between these values and the operating microscope light exposure time along with the cumulative dissipated energy (CDE) were investigated. There was a significant deterioration of all dry eye test values following phacoemulsification surgery along with an increase in subjective symptoms. These values started improving after 1-month postoperatively, but preoperative levels were not achieved till 2 months after surgery. Correlations of dry eye test values were noted with the operating microscope light exposure time and CDE, but they were not significant. Phacoemulsification surgery is capable of inducing dry eye, and patients should be informed accordingly prior to surgery. The clinician should also be cognizant that increased CDE can induce dry eyes even in eyes that were healthy preoperatively. In addition, intraoperative exposure to the microscopic light should be minimized.

  5. Intraoperative radiotherapy for cancer of the pancreas

    International Nuclear Information System (INIS)

    Manabe, Tadao; Nagai, Toshihiro; Tobe, Takayoshi; Shibamoto, Yuta; Takahashi, Masaharu; Abe, Mitsuyuki

    1985-01-01

    Seven patients treated by intraoperative radiotherapy for cancer of the pancreas were evaluated. Three patients undergoing pancreaticoduodenectomy for cancer of the head of the pancreas received a dose of 2,500--3,000 rad (6--10 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 2,520 rad (10 MeV lineac X-ray). One patient developed radiation pancreatitis and died 0.8 month after surgery. Autopsy revealed the degeneration of cancer cells in the involved superior mesenteric artery. One died of hepatic metastasis 8.5 months after surgery, however, recurrence was not found in the irradiation field. The other patient who had external beam irradiation combined with intraoperative radiotherapy is alive 7.5 months after surgery. Four patients with unresectable cancer of the body of the pancreas received a dose of 2,500--3,000 rad (13--18 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 1,500--5,520 rad (10 MeV lineac X-ray). One patient died of peritonitis carcinomatosa 3.0 months after surgery. One patient died of DIC 0.6 month after surgery. Two patients are alive 1.0 and 6.5 months after surgery. In these patients with intraoperative radiotherapy for unresectable cancer of the pancreas, remarkable effects on relief of pain and shrinkage of tumor were obtained. Further pursuit of intraoperative and external beam radiotherapies in combination with pancreatectomy should be indicated in an attempt to prolong survival of patient with cancer of the pancreas. (author)

  6. Concomitant radio- and fluorescence-guided sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity using ICG-{sup 99m}Tc-nanocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Nynke S. van den; Leeuwen, Fijs W.B. van [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leiden University Medical Center, Department of Radiology, Interventional Molecular Imaging Section, Albinusdreef 2 (C2-S zone), P.O. Box 9600, Leiden (Netherlands); Brouwer, Oscar R.; Valdes Olmos, Renato A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Klop, W.M.C.; Karakullukcu, Baris; Zuur, Charlotte L.; Tan, I.B.; Balm, Alfons J.M.; Brekel, Michiel W.M. van den [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2012-07-15

    For oral cavity malignancies, sentinel lymph node (SLN) mapping is performed by injecting a radiocolloid around the primary tumour followed by lymphoscintigraphy. Surgically, SLNs can then be localized using a handheld gamma ray detection probe. The aim of this study was to evaluate the added value of intraoperative fluorescence imaging to the conventional radioguided procedure. For this we used indocyanine green (ICG)-{sup 99m}Tc-nanocolloid, a hybrid tracer that is both radioactive and fluorescent. Fourteen patients with oral cavity squamous cell carcinoma were peritumourally injected with ICG-{sup 99m}Tc-nanocolloid. SLNs were preoperatively identified with lymphoscintigraphy followed by single photon emission computed tomography (SPECT)/CT for anatomical localization. During surgery, SLNs were detected with a handheld gamma ray detection probe and a handheld near-infrared fluorescence camera. Pre-incision and post-excision imaging with a portable gamma camera was performed to confirm complete removal of all SLNs. SLNs were preoperatively identified using the radioactive signature of ICG-{sup 99m}Tc-nanocolloid. Intraoperatively, 43 SLNs could be localized and excised with combined radio- and fluorescence guidance. Additionally, in four patients, an SLN located close to the primary injection site (in three patients this SLN was located in level I) could only be intraoperatively localized using fluorescence imaging. Pathological analysis of the SLNs revealed a metastasis in one patient. Combined preoperative SLN identification and intraoperative radio- and fluorescence guidance during SLN biopsies for oral cavity cancer proved feasible using ICG-{sup 99m}Tc-nanocolloid. The addition of fluorescence imaging was shown to be of particular value when SLNs were located in close proximity to the primary tumour. (orig.)

  7. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Shaffer, Travis M.; Tang, Jun; Austin, Christine; Arora, Manish; Zeglis, Brian M.; Grimm, Jan; Eppinger, Jö rg; Reiner, Thomas

    2016-01-01

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Büchel, Gabriel E.

    2016-08-03

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. CHARACTERISTICS OF EPIRETINAL MEMBRANE REMNANT EDGE BY OPTICAL COHERENCE TOMOGRAPHY AFTER PARS PLANA VITRECTOMY.

    Science.gov (United States)

    Gaber, Raouf; You, Qi Sheng; Muftuoglu, Ilkay Kilic; Alam, Mostafa; Tsai, Frank F; Mendoza, Nadia; Freeman, William R

    2017-11-01

    To evaluate the incidence, characteristics, and the progression of epiretinal membrane (ERM) remnant edge seen by optical coherence tomography after ERM peeling. A retrospective chart review was conducted for 86 eyes of 85 consecutive patients who were diagnosed with ERM and underwent pars plana vitrectomy for epiretinal membrane peeling between 2013 and 2014. Data collected and analyzed included age, gender, preoperative and postoperative visual acuity, use of indocyanine green dye to stain internal limiting membrane, tamponade used after vitrectomy, ERM edge boundaries, presence of cystoid macular edema, and central foveal thickness. An ERM remnant edge was detected in 33/86 study eyes (38.4%) at the first postoperative optical coherence tomography scan. Compared with those without an ERM remnant, patients with an ERM remnant after surgery were significantly older at baseline and had a higher incidence of ERM recurrence at their last visit. They were not significantly different in terms of gender, preoperative and postoperative visual acuity, reduction of central foveal thickness from baseline, proportion of eyes with preoperative ERM elevation on optical coherence tomography, presence of macular edema before surgery, intraoperative use of indocyanine green staining for ILM peeling, or tamponade used. Based on the edge morphology, we classified the ERM remnant into three types: Type 1 was flat and blended with the retina (14/33 eyes, 42.4%), Type 2 was flat but stepped (17/33 eyes, 51.5%), and Type 3 was elevated (2/33 eyes, 6.0%). A significantly higher risk of ERM recurrence was seen in Type 2 and Type 3 ERM remnants (75% and 100%, respectively) than Type 1 ERM remnants (10%). An ERM remnant edge was detected by optical coherence tomography after ERM peeling in 38.4% of eyes. The presence of a postoperative ERM edge was associated with a higher risk of ERM recurrence, particularly in Type 2 and Type 3 ERM remnants.

  10. A review of performance of near-infrared fluorescence imaging devices used in clinical studies

    Science.gov (United States)

    Zhu, B

    2015-01-01

    Near-infrared fluorescence (NIRF) molecular imaging holds great promise as a new “point-of-care” medical imaging modality that can potentially provide the sensitivity of nuclear medicine techniques, but without the radioactivity that can otherwise place limitations of usage. Recently, NIRF imaging devices of a variety of designs have emerged in the market and in investigational clinical studies using indocyanine green (ICG) as a non-targeting NIRF contrast agent to demark the blood and lymphatic vasculatures both non-invasively and intraoperatively. Approved in the USA since 1956 for intravenous administration, ICG has been more recently used off label in intradermal or subcutaneous administrations for fluorescence imaging of the lymphatic vasculature and lymph nodes. Herein, we summarize the devices of a variety of designs, summarize their performance in lymphatic imaging in a tabular format and comment on necessary efforts to develop standards for device performance to compare and use these emerging devices in future, NIRF molecular imaging studies. PMID:25410320

  11. Imaging of Lymph Flow in Breast Cancer Patients after Microdose Administration of a Near-Infrared Fluorophore: Feasibility Study1

    Science.gov (United States)

    Sevick-Muraca, Eva M.; Sharma, Ruchi; Rasmussen, John C.; Marshall, Milton V.; Wendt, Juliet A.; Pham, Hoang Q.; Bonefas, Elizabeth; Houston, Jessica P.; Sampath, Lakshmi; Adams, Kristen E.; Blanchard, Darlene Kay; Fisher, Ronald E.; Chiang, Stephen B.; Elledge, Richard; Mawad, Michel E.

    2011-01-01

    Purpose To prospectively demonstrate the feasibility of using indocyanine green, a near-infrared (NIR) fluorophore at the minimum dose needed for noninvasive optical imaging of lymph nodes (LNs) in breast cancer patients undergoing sentinel lymph node mapping (SLNM). Materials and Methods Informed consent was obtained from 24 women (age range, 30–85 years) who received intradermal subcutaneous injections of 0.31–100 μg indocyanine green in the breast in this IRB-approved, HIPAA-compliant, dose escalation study to find the minimum microdose for imaging. The breast, axilla, and sternum were illuminated with NIR light and the fluorescence generated in the tissue was collected with an NIR-sensitive intensified charged-coupled device. Lymphoscintigraphy was also performed. Resected LNs were evaluated for the presence of radioactivity, blue dye accumulation, and fluorescence. The associations between the resected LNs that were fluorescent and (a) the time elapsed between NIR fluorophore administration and resection and (b) the dosage of NIR fluorophores were tested with the Spearman rank and Pearson product moment correlation tests, respectively. Results Lymph imaging consistently failed with indocyanine green microdosages between 0.31 and 0.77 μg. When indocyanine green dosages were 10 μg or higher, lymph drainage pathways from the injection site to LNs were imaged in eight of nine women; lymph propulsion was observed in seven of those eight. When propulsion in the breast and axilla regions was present, the mean apparent velocities ranged from 0.08 to 0.32 cm/sec, the time elapsed between “packets” of propelled fluid varied from 14 to 92 seconds. In patients who received 10 μg of indocyanine green or more, a weak negative correlation between the fluorescence status of resected LNs and the time between NIR fluorophore administration and LN resection was found. No statistical association was found between the fluorescence status of resected LNs and the dose of

  12. Intraoperative radiotherapy for adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Yasue, Mitsunori; Yasui, Kenzo; Morimoto, Takeshi; Miyaishi, Seiichi; Morita, Kozo

    1986-01-01

    Thirty-six patients were given intraoperative radiotherapy for adenocarcinoma of the pancreas between April 1980 and March 1986. Twenty-six of those with well-advanced cancer underwent palliative intraoperative radiotherapy of their main primary lesions (1,500 to 3,000 rads). Fourteen of the 19 patients in this group who had intractable back pain before surgery achieved relief within one week after treatment. Of the remaining 10 patients who underwent pancreatectomy and received adjuvant intraoperative radiotherapy (2,000 to 3,000 rads), two remain clinically free of disease five years and six months and four years and six months after palliative distal pancreatectomy. (author)

  13. A non-docking intraoperative electron beam applicator system

    International Nuclear Information System (INIS)

    Palta, J.R.; Suntharalingam, N.

    1989-01-01

    A non-docking intraoperative radiation therapy electron beam applicator system for a linear accelerator has been designed to minimize the mechanical, electrical, and tumor visualization problems associated with a docking system. A number of technical innovations have been used in the design of this system. These include: (a) a new intraoperative radiation therapy cone design that gives a better dose uniformity in the treatment volume at all depths; (b) a collimation system which reduces the leakage radiation dose to tissues outside the intraoperative radiation therapy cone; (c) a non-docking system with a translational accuracy of 2 mm and a rotational accuracy of 0.5 degrees; and (d) a rigid clamping system for the cones. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented

  14. Intraoperative complications in pediatric neurosurgery: review of 1807 cases.

    Science.gov (United States)

    van Lindert, Erik J; Arts, Sebastian; Blok, Laura M; Hendriks, Mark P; Tielens, Luc; van Bilsen, Martine; Delye, Hans

    2016-09-01

    OBJECTIVE Minimal literature exists on the intraoperative complication rate of pediatric neurosurgical procedures with respect to both surgical and anesthesiological complications. The aim of this study, therefore, was to establish intraoperative complication rates to provide patients and parents with information on which to base their informed consent and to establish a baseline for further targeted improvement of pediatric neurosurgical care. METHODS A clinical complication registration database comprising a consecutive cohort of all pediatric neurosurgical procedures carried out in a general neurosurgical department from January 1, 2004, until July 1, 2012, was analyzed. During the study period, 1807 procedures were performed on patients below the age of 17 years. RESULTS Sixty-four intraoperative complications occurred in 62 patients (3.5% of procedures). Intraoperative mortality was 0.17% (n = 3). Seventy-eight percent of the complications (n = 50) were related to the neurosurgical procedures, whereas 22% (n = 14) were due to anesthesiology. The highest intraoperative complication rates were for cerebrovascular surgery (7.7%) and tumor surgery (7.4%). The most frequently occurring complications were cerebrovascular complications (33%). CONCLUSIONS Intraoperative complications are not exceptional during pediatric neurosurgical procedures. Awareness of these complications is the first step in preventing them.

  15. Fluorescence guided surgery and tracer-dose, fact or fiction?

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Olmos, Renato A.V.; Bunschoten, Anton; Berg, Nynke S. van den; Klop, W.M.C.; Horenblas, Simon; Poel, Henk G. van der; Wester, Hans-Juergen; Leeuwen, Fijs W.B. van

    2016-01-01

    Fluorescence guidance is an upcoming methodology to improve surgical accuracy. Challenging herein is the identification of the minimum dose at which the tracer can be detected with a clinical-grade fluorescence camera. Using a hybrid tracer such as indocyanine green (ICG)- 99m Tc-nanocolloid, it has become possible to determine the accumulation of tracer and correlate this to intraoperative fluorescence-based identification rates. In the current study, we determined the lower detection limit of tracer at which intraoperative fluorescence guidance was still feasible. Size exclusion chromatography (SEC) provided a laboratory set-up to analyze the chemical content and to simulate the migratory behavior of ICG-nanocolloid in tissue. Tracer accumulation and intraoperative fluorescence detection findings were derived from a retrospective analysis of 20 head-and-neck melanoma patients, 40 penile and 20 prostate cancer patients scheduled for sentinel node (SN) biopsy using ICG- 99m Tc-nanocolloid. In these patients, following tracer injection, single photon emission computed tomography fused with computed tomography (SPECT/CT) was used to identify the SN(s). The percentage injected dose (% ID), the amount of ICG (in nmol), and the concentration of ICG in the SNs (in μM) was assessed for SNs detected on SPECT/CT and correlated with the intraoperative fluorescence imaging findings. SEC determined that in the hybrid tracer formulation, 41 % (standard deviation: 12 %) of ICG was present in nanocolloid-bound form. In the SNs detected using fluorescence guidance a median of 0.88 % ID was present, compared to a median of 0.25 % ID in the non-fluorescent SNs (p-value < 0.001). The % ID values could be correlated to the amount ICG in a SN (range: 0.003-10.8 nmol) and the concentration of ICG in a SN (range: 0.006-64.6 μM). The ability to provide intraoperative fluorescence guidance is dependent on the amount and concentration of the fluorescent dye accumulated in the lesion(s) of

  16. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    Science.gov (United States)

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  17. Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study.

    Science.gov (United States)

    Boni, Luigi; Fingerhut, Abe; Marzorati, Alessandro; Rausei, Stefano; Dionigi, Gianlorenzo; Cassinotti, Elisa

    2017-04-01

    Colorectal anastomoses after anterior resection for cancer carry a high risk of leakage. Different factors might influence the correct healing of anastomosis, but adequate perfusion of the bowel is highlighted as one of the most important elements. Fluorescence angiography (FA) is a new technique that allows the surgeon to perform real-time intraoperative angiography to evaluate the perfusion of the anastomosis and hence, potentially, reduce leak rate. The aim of this study was to evaluate the impact of FA of the bowel on postoperative complications and anastomotic leakage after laparoscopic anterior resection with total mesorectal excision (TME). FA was performed in all patients undergoing laparoscopic anterior resection with TME for cancer followed by colorectal or coloanal anastomosis. Results were compared to a historical controls group of 38 patients previously operated by the same surgeon for the same indication but without the use of FA. From October 2014 to November 2015, 42 patients underwent laparoscopic anterior resection with TME and FA of the bowel. The surgeon subjectively decided to change the planned anastomotic level of the descending colon due to hypoperfused distal segment in two out of 42 patients in the FA group (4.7 %). Anastomotic leakage, confirmed by postoperative CT scan and water-soluble contrast enema, was found in two cases of a historical controls group and none in the FA group. No adverse events (side effects or allergic reaction) related to FA were recorded. All the other postoperative complications were comparable between the two groups. In our experience, ICG FA was safe and effective in low rectal cancer resection, possibly leading to a reduction in the anastomotic leakage rate after TME.

  18. Glioma surgery using intraoperative tractography and MEP monitoring

    International Nuclear Information System (INIS)

    Maesawa, Satoshi; Nakahara, Norimoto; Watanabe, Tadashi; Fujii, Masazumi; Yoshida, Jun

    2009-01-01

    In surgery of gliomas in motor-eloquent locations, it is essential to maximize resection while minimizing motor deficits. We attempted to identify the cortico-spinal tract (CST) by intraoperative-diffusion tensor imaging (DTI) tractography, combined with electrophysiological mapping using direct subcortical stimulation during tumor resection. Our techniques and preliminary results are reported. Tumors were removed from twelve patients with gliomas in and around the CST using high-field intraoperative MRI and neuronavigation system (BrainSUITE). DTI-based tractography was implemented for navigation of CST pre-and intraoperatively. When the CST was close to the manipulating area, direct subcortical stimulation was performed, and motor evoked potential (MEP)-responses were examined. Locations of CST indicated by pre- and intraoperative tractography (pre- or intra-CST-tractography), and locations identified by subcortical stimulation were recorded, and those correlations were examined. Imaging and functional outcomes were reviewed. Total resections were achieved in 10 patients (83.4%). Two patients developed transient deterioration of motor function (16.6%), and permanent paresis was seen in one (8.3%). The distance from intra-CST-tractography to corresponding sites by subcortical stimulation was 4.5 mm in average (standard deviation (SD)=4.2), and significantly shorter than from pre-CST-tractography. That distance correlated significantly with the intensity of subcortical stimulation. We observed that intraoperative DTI-tractography demonstrated the location of the pyramidal tract more accurately than preoperative one. The combination of intraoperative tractgraphy and MEP monitoring enhanced the quality of surgery for gliomas in motor-eloquent area. (author)

  19. Intraoperative parathyroid hormone assay-cutting the Gordian knot

    Directory of Open Access Journals (Sweden)

    Chandralekha Tampi

    2014-01-01

    Full Text Available Background: Hyperparathyroidism is treated by surgical excision of the hyperfunctioning parathyroid gland. In case of adenoma the single abnormal gland is removed, while in hyperplasias, a subtotal excision, that is, three-and-a-half of the four glands are removed. This therapeutic decision is made intraoperatively through frozen section evaluation and is sometimes problematic, due to a histological overlap between hyperplasia and the adenoma. The intraoperative parathyroid hormone (IOPTH assay, propogated in recent years, offers an elegant solution, with a high success rate, due to its ability to identify the removal of all hyperfunctioning parathyroid tissue. Aim: To study the feasibility of using IOPTH in our setting. Materials and Methods: Seven patients undergoing surgery for primary hyperparathyroidism had their IOPTH levels evaluated, along with the routine frozen and paraffin sections. Results: All seven patients showed more than a 50% intraoperative fall in serum PTH after excision of the abnormal gland. This was indicative of an adenoma and was confirmed by histopathological examination and normalization of serum calcium postoperatively. Conclusion: The intraoperative parathyroid hormone is a sensitive and specific guide to a complete removal of the abnormal parathyroid tissue. It can be incorporated without difficulty as an intraoperative guide and is superior to frozen section diagnosis in parathyroid surgery.

  20. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  1. Intra-operative radiotherapy of malignant tumors: Past, present and perspectives

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Le Bourgeois, J.P.; Ganem, G.

    1986-01-01

    Intra-operative radiotherapy consists of electron or photon radiation which is used during the operative procedure. The treatment field is arranged very precisely after critical organs have been previously arranged out of the field. The target volume includes the remaining tumor which could not be removed surgically, and the surrounding tumor bed which is also felt to be high risk for recurrence. It is preferable to have as little tumor remaining as possible before the intra-operative treatment radiation is given. Intra-operative radiotherapy was developed less than a quarter century ago in Japon, and it was later used in U.S.A. The accumulated experience in Japan and U.S.A. is rewieved here. Intra-operative radiotherapy has only recently been introduced to France. The biology, physics and medical and technical problems of intra-operative therapy are discussed [fr

  2. Spinal infection: Evaluation with MR imaging and intraoperative spinal US

    International Nuclear Information System (INIS)

    Donovan Post, M.J.; Montalvo, B.M.; Quencer, R.M.; Katz, B.H.; Green, B.A.; Elsmont, F.

    1987-01-01

    MR spine images and/or intraoperative US scans in 15 patients were reviewed retrospectively and correlated with clinical and pathologic data to determine the diagnostic value of these modalities in spinal infection. In osteomyelitis and retrospinal abscess MR imaging was definitive; in myelitis it was positive but nonspecific. In epidural abscess concomitant with meningitis, myelography with CT and intraoperative US were superior to MR imaging. Intraoperative US could be used to distinguish these processes and to monitor surgical decompression. The authors recommend that MR imaging be performed at the screening examination in cases of spinal infection, accompanied by intraoperative US in all surgical cases

  3. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  4. ICG-fluorescence imaging for detection of peritoneal metastases and residual tumoral scars in locally advanced ovarian cancer: A pilot study.

    Science.gov (United States)

    Veys, Isabelle; Pop, Florin-Catalin; Vankerckhove, Sophie; Barbieux, Romain; Chintinne, Marie; Moreau, Michel; Nogaret, Jean-Marie; Larsimont, Denis; Donckier, Vincent; Bourgeois, Pierre; Liberale, Gabriel

    2018-02-01

    No intraoperative imaging techniques exist for detecting tumor nodules or tumor scar tissues in patients treated with upfront or interval cytoreductive surgery (CS) after neoadjuvant chemotherapy (NAC). The aims of this study were to evaluate the role of indocyanine green (ICG) fluorescence imaging (FI) for the detection of peritoneal metastases (PM) and evaluate whether it can be used to detect remnant tumor cells in scar tissue. Patients with PM from ovarian cancer admitted for CS were included. ICG, at 0.25 mg per kg of patient weight, was injected intraoperatively after explorative laparotomy before CS. A total of 108 peritoneal lesions, including 25 scars, were imaged in 20 patients. Seventy-three were malignant (67.6%) and 35 benign (32.4%). The mean Tumor to Background Ratio (ex vivo) was 1.8 (SD 1.3) in malignant and 1.0 (SD 0.79) in benign nodules (P = 0.007). Of 25 post-NAC scars, the mean Tumor to Background Ratio (TBR) (in vivo) was 2.06 (SD 1.15) in malignant and 1.21 (SD 0.50) in benign nodules (P = 0.26). The positive predictive value of ICG-FI to detect tumor cells in scars was 57.1%. ICG-FI is accurate to demonstrate PM in ovarian cancer but unable to discriminate between benign and malignant post-NAC. © 2017 Wiley Periodicals, Inc.

  5. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR METASTATIC PERITONEAL TUMORS

    Directory of Open Access Journals (Sweden)

    E. A. Suleimanov

    2016-01-01

    Full Text Available This review is devoted to the cytoreductive treatment of malignant tumors of the abdominal organs. The actuality of the issue is determined both by increase of the incidence of abdominal cancer in Russia and in majority of developed countries and by high rate diagnosis on late stages of disease. The methods of treatment of peritoneal carcinomatosis, based on possible effects on the secondary peritoneal tumors after surgical cytoreduction to reduce the risk of local recurrence and disease progression are described. These methods of additional intraoperative specific antitumor action include intraoperative radiation therapy, hyperthermic intraperitoneal chemotherapy, intraoperative photodynamic therapy characterized by differences in difficulty of performance, mechanisms of effect on tumor and healthy tissues, efficiency. Benefits, opportunities and possibilities of application of intraoperative photodynamic therapy (IOPDT for secondary peritoneal tumors are described in details, the results of a number of domestic and foreign clinical studies are shown, the successful application of intraoperative photodynamic therapy in clinical oncology, which allows reducing the risk of secondary tumor lesions of the peritoneum significantly, is demonstrated. Photodynamic therapy – a method with high efficiency and almost no side effects and complications, based on the ability of photosensitizer to accumulate selectively and retain in the high proliferative tissues. The advantages of this type of treatment of patients with peritoneal carcinomatosis are a selective effect on the peritoneal carcinomatosis and on visually detected tumor tissue, high efficiency in patients with malignant tumors of the abdominal cavity and pelvis combined with surgical cytoreduction, minimal effect on normal organs and tissues of the patient, well tolerated procedure.

  7. Towards green loyalty: the influences of green perceived risk, green image, green trust and green satisfaction

    Science.gov (United States)

    Chrisjatmiko, K.

    2018-01-01

    The paper aims to present a comprehensive framework for the influences of green perceived risk, green image, green trust and green satisfaction to green loyalty. The paper also seeks to account explicitly for the differences in green perceived risk, green image, green trust, green satisfaction and green loyalty found among green products customers. Data were obtained from 155 green products customers. Structural equation modeling was used in order to test the proposed hypotheses. The findings show that green image, green trust and green satisfaction has positive effects to green loyalty. But green perceived risk has negative effects to green image, green trust and green satisfaction. However, green perceived risk, green image, green trust and green satisfaction also seems to be a good device to gain green products customers from competitors. The contributions of the paper are, firstly, a more complete framework of the influences of green perceived risk, green image, green trust and green satisfaction to green loyalty analyses simultaneously. Secondly, the study allows a direct comparison of the difference in green perceived risk, green image, green trust, green satisfaction and green loyalty between green products customers.

  8. Intraoperative MRI to control the extent of brain tumor surgery

    International Nuclear Information System (INIS)

    Knauth, M.; Sartor, K.; Wirtz, C.R.; Tronnier, V.M.; Staubert, A.; Kunze, S.

    1998-01-01

    Intraoperative MRI definitely showed residual tumor in 6 of the 18 patients and resulted in ambiguous findings in 3 patients. In 7 patients surgery was continued. Early postoperative MRI showed residual tumor in 3 patients and resulted in uncertain findings in 2 patients. The rate of patients in whom complete removal of enhancing tumor could be achieved was 50% at the time of the intraoperative MR examination and 72% at the time of the early postoperative MR control. The difference in proportion of patients with 'complete tumor removal' between the groups who had been operated on using neuronavigation (NN) and intraoperative MRI (ioMRI) and those who had been operated on using only modern neurosurgical techniques except NN and ioMRI was statistically highly significant (Fisher exact test; P=0.008). Four different types of surgically induced contrast enhancement were observed. These phenomena carry different confounding potentials with residual tumor. Conclusion: Our preliminary experience with intraoperative MRI in patients with enhancing intraaxial tumors is encouraging. Combined use of neuronavigation and intraoperative MRI was able to increase the proportion of patients in whom complete removal of the enhancing parts of the tumor was achieved. Surgically induced enhancement requires careful analysis of the intraoperative MRI in order not to confuse it with residual tumor. (orig.) [de

  9. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  10. Intraoperative use of ultrasonography by small subcortical lesions

    International Nuclear Information System (INIS)

    Kondoff, Sl.; Gabrovski, St.; Krustev, E.; Poptodorov, G.; Gabrovski, N.; Uzunov, K.

    2004-01-01

    The aim of this study is to present the possibilities for use of intraoperative ultrasound (US) diagnostics as a method of image guided surgical navigation in neurosurgery. During an US scan of normal and pathologically changed tissues as well as volume taking lesion images are received in real time intraoperative display allowing dynamic control of the surgical radicalism and at the same time minimal invasiveness to the neural structures. Intraoperative ultrasound with real-time display characteristics finds a very wide application: subcortical and deeply localized tumour lesions, haematomas, large and giant aneurysms, arteriovenous (AV) malformations, spinal tumours and cysts. The real time dynamic scan is based on the B-mod. This method is founded on the US characteristic of reflecting in a different manner at the borderline of two mediums with different density as well as tissues with various physical and chemical characteristics. The reflection is partially absorbed depending on the acoustic impedance of the biologic field. We use a LOGIC200PRO unit with two probes I-type and T-type having a 'wedge of space' - 35 mm and working frequencies of 6 MHz and 7 MHz appropriate for visualizing lesions at a depth of 25 to 60 mm.The advantages of the Intraoperative US diagnostics are: non-invasiveness; real time display - i.e. presents the imminent intraoperative changes; it is a good alternative to other image-guided technologies; accessible price of the US unit

  11. The Resection Map : A proposal for intraoperative hepatectomy guidance

    NARCIS (Netherlands)

    Lamata, P.; Jalote-Parmar, A.; Lamata, F.; Declerck, J.

    2008-01-01

    Objective - To propose a new concept of an intra-operative 3D visualisation system to support hepatectomies. This system aims at improving the transfer of pre-operative planning into the intra-operative stage, both in laparoscopic and open approaches. Materials and methods - User (surgeon) centred

  12. [Factors related to intraoperative retinal breaks in macular hole surgery].

    Science.gov (United States)

    Kumagai, K; Ogino, N; Demizu, S; Atsumi, K; Kurihara, H; Iwaki, M; Ishigooka, H; Tachi, N

    2001-02-01

    To evaluate the factors of intraoperative retinal breaks in macular hole surgery. This study included 558 eyes of 506 patients who underwent idiopathic macular hole surgery by one surgeon. Multiple regression was performed using the variables of gender, age, affected eye, lens status, stage, duration of symptoms, hole size, axial length, and lattice degeneration. The rate of retinal breaks was higher in stage 3 (16.0%) than in stage 4 (8.2%) (p = 0.014). In eyes with lattice degeneration intraoperative retinal breaks occurred in about 40% of the cases. Major factors were as follows: lattice degeneration (r = 0.24, p lattice degeneration, and gender (r = -0.18, p = 0.035) in eyes of stage 4 without lattice degeneration. The factors of intraoperative retinal breaks in macular hole surgery were lattice degeneration in all eyes and stage 3 in eyes without lattice degeneration. The high incidence of intraoperative retinal breaks in stage 3 was mainly due to the occurrence of posterior vitreous detachment. Male gender was a significant factor associated with intraoperative retinal breaks.

  13. Targeted intraoperative radiotherapy in oncology

    CERN Document Server

    Keshtgar, Mohammed; Wenz, Frederik

    2014-01-01

    Targeted intraoperative radiotherapy is a major advance in the management of cancer patients. With an emphasis on practical aspects, this book offers an ideal introduction to this innovative  technology for clinicians.

  14. Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.

    Science.gov (United States)

    Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak

    2017-07-01

    Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score Secondary insults examined were: systemic hypotension (systolic blood pressurehypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure40 mm Hg), hypocarbia (end-tidal CO2hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (Psecondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.

  15. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  16. Multispectral open-air intraoperative fluorescence imaging.

    Science.gov (United States)

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  17. Intraoperative lung ultrasound: A clinicodynamic perspective

    Directory of Open Access Journals (Sweden)

    Amit Kumar Mittal

    2016-01-01

    Full Text Available In the era of evidence-based medicine, ultrasonography has emerged as an important and indispensable tool in clinical practice in various specialties including critical care. Lung ultrasound (LUS has a wide potential in various surgical and clinical situations for timely and easy detection of an impending crisis such as pulmonary edema, endobronchial tube migration, pneumothorax, atelectasis, pleural effusion, and various other causes of desaturation before it clinically ensues to critical level. Although ultrasonography is frequently used in nerve blocks, airway handling, and vascular access, LUS for routine intraoperative monitoring and in crisis management still necessitates recognition. After reviewing the various articles regarding the use of LUS in critical care, we found, that LUS can be used in various intraoperative circumstances similar to Intensive Care Unit with some limitations. Except for few attempts in the intraoperative detection of pneumothorax, LUS is hardly used but has wider perspective for routine and crisis management in real-time. If anesthesiologists add LUS in their routine monitoring armamentarium, it can assist to move a step ahead in the dynamic management of critically ill and high-risk patients.

  18. Virus-resembling nano-structures for near infrared fluorescence imaging of ovarian cancer HER2 receptors

    Science.gov (United States)

    Guerrero, Yadir A.; Bahmani, Baharak; Singh, Sheela P.; Vullev, Valentine I.; Kundra, Vikas; Anvari, Bahman

    2015-10-01

    Ovarian cancer remains the dominant cause of death due to malignancies of the female reproductive system. The capability to identify and remove all tumors during intraoperative procedures may ultimately reduce cancer recurrence, and lead to increased patient survival. The objective of this study is to investigate the effectiveness of an optical nano-structured system for targeted near infrared (NIR) imaging of ovarian cancer cells that over-express the human epidermal growth factor receptor 2 (HER2), an important biomarker associated with ovarian cancer. The nano-structured system is comprised of genome-depleted plant-infecting brome mosaic virus doped with NIR chromophore, indocyanine green, and functionalized at the surface by covalent attachment of monoclonal antibodies against the HER2 receptor. We use absorption and fluorescence spectroscopy, and dynamic light scattering to characterize the physical properties of the constructs. Using fluorescence imaging and flow cytometry, we demonstrate the effectiveness of these nano-structures for targeted NIR imaging of HER2 receptors in vitro. These functionalized nano-materials may provide a platform for NIR imaging of ovarian cancer.

  19. Virus-resembling nano-structures for near infrared fluorescence imaging of ovarian cancer HER2 receptors

    International Nuclear Information System (INIS)

    Guerrero, Yadir A; Bahmani, Baharak; Vullev, Valentine I; Anvari, Bahman; Singh, Sheela P; Kundra, Vikas

    2015-01-01

    Ovarian cancer remains the dominant cause of death due to malignancies of the female reproductive system. The capability to identify and remove all tumors during intraoperative procedures may ultimately reduce cancer recurrence, and lead to increased patient survival. The objective of this study is to investigate the effectiveness of an optical nano-structured system for targeted near infrared (NIR) imaging of ovarian cancer cells that over-express the human epidermal growth factor receptor 2 (HER2), an important biomarker associated with ovarian cancer. The nano-structured system is comprised of genome-depleted plant-infecting brome mosaic virus doped with NIR chromophore, indocyanine green, and functionalized at the surface by covalent attachment of monoclonal antibodies against the HER2 receptor. We use absorption and fluorescence spectroscopy, and dynamic light scattering to characterize the physical properties of the constructs. Using fluorescence imaging and flow cytometry, we demonstrate the effectiveness of these nano-structures for targeted NIR imaging of HER2 receptors in vitro. These functionalized nano-materials may provide a platform for NIR imaging of ovarian cancer. (paper)

  20. Selected versus routine use of intraoperative cholangiography during laparoscopic cholecystectomy.

    Science.gov (United States)

    Pickuth, D

    1995-12-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments, however, this is discussed controversially. We have developed a new diagnostic strategy to detect bile duct stones. The concept is based on an ultrasound examination and on a screening for the presence of six risk indicators of choledocholithiasis. 120 consecutive patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of six risk indicators of choledocholithiasis: history of jaundice; history of pancreatitis; hyperbilirubinemia; hyperamylasemia; dilated bile duct; unclear ultrasound findings. The sensitivity of ultrasound and of intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. 20% of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (p concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that the routine use of intraoperative cholangiography in patients undergoing laparoscopic cholecystectomy is not necessary.

  1. Fluorescent Angiography Used to Evaluate the Perfusion Status of Anastomosis in Laparoscopic Anterior Resection.

    Science.gov (United States)

    Koh, Frederick H; Tan, Ker-Kan

    2016-12-01

    Anastomotic leakage after gastrointestinal surgery is associated with significant morbidity and mortality.1 Insufficient vascular supply is one cause.2 Recent reports of using intraoperative indocyanine green (ICG) fluorescent angiography to evaluate whether perfusion of the anastomosis is adequate has yielded positive outcomes.3 - 6 The authors describe their use of ICG-enhanced fluorescence angiography in a laparoscopic anterior resection. The patient was an 80-year-old with an upper rectal adenocarcinoma and significant cardiovascular risk factors. Fluorescence angiography with 0.4 mg/kg of ICG was administered intravenously just before the colorectal anastomosis was fashioned. A near-infrared (NIR) laparoscopic camera (KARLSTORZ, GmbH & Co. KG, Tuttlingen, Germany) was used to inspect the anastomosis. For this video, 0.4 mg/kg of ICG also was injected after ligation of the inferior mesenteric artery to demonstrate the appearance of a poorly perfused sigmoid bowel. Just before the staple was fired to fashion the colorectal anastomosis, an intravenous bolus of ICG was administered. Within seconds, vessels on both ends of the anastomosis turned fluorescent blue, indicating adequacy of perfusion. The use of ICG did not significantly lengthen the operative time (285 min) because its effect appeared within seconds after its administration. The patient recovered well and was discharged on postoperative day 5. Another four patients who also underwent intraoperative fluorescent angiography for left-sided colorectal lesions did not experience anastomotic leakage. The study showed that ICG fluorescent angiography is a simple and quick intraoperative tool for evaluating the perfusion of the anastomosis. The authors' experience with ICG fluorescent angiography has shown promising results, with a 0 % anastomotic leak rate.

  2. Presurgical mapping with magnetic source imaging. Comparisons with intraoperative findings

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Ferrari, P.; Perry, D.; Rowley, H.A.; Berger, M.S.

    2000-01-01

    We compare noninvasive preoperative mapping with magnetic source imaging to intraoperative cortical stimulation mapping. These techniques were directly compared in 17 patients who underwent preoperative and postoperative somatosensory mapping of a total of 22 comparable anatomic sites (digits, face). Our findings are presented in the context of previous studies that used magnetic source imaging and functional magnetic resonance imaging as noninvasive surrogates of intraoperative mapping for the identification of sensorimotor and language-specific brain functional centers in patients with brain tumors. We found that magnetic source imaging results were reasonably concordant with intraoperative mapping findings in over 90% of cases, and that concordance could be defined as 'good' in 77% of cases. Magnetic source imaging therefore provides a viable, if coarse, identification of somatosensory areas and, consequently, can guide and reduce the time taken for intraoperative mapping procedures. (author)

  3. Intraoperative electron beam radiation therapy (IOEBRT) for carcinoma of the exocrine pancreas

    International Nuclear Information System (INIS)

    Dobelbower, R.R. Jr.; Konski, A.A.; Merrick, H.W. III; Bronn, D.G.; Schifeling, D.; Kamen, C.

    1991-01-01

    The abdominal cavities of 50 patients were explored in a specially constructed intraoperative radiotherapy operating amphitheater at the Medical College of Ohio. Twenty-six patients were treated with intraoperative and postoperative precision high dose external beam therapy, 12 with intraoperative irradiation but no external beam therapy, and 12 with palliative surgery alone. All but two patients completed the postoperative external beam radiation therapy as initially prescribed. The median survival time for patients treated with palliative surgery alone was 4 months, and that for patients treated with intraoperative radiotherapy without external beam therapy was 3.5 months. Patients undergoing intraoperative irradiation and external beam radiation therapy had a median survival time of 10.5 months. Four patients died within 30 days of surgery and two patients died of gastrointestinal hemorrhage 5 months posttreatment

  4. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  5. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    International Nuclear Information System (INIS)

    Sty, J.; Simons, G.

    1982-01-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success

  6. The clinical practice of intraoperative neurophysiological monitoring in Shanghai Huashan Hospital

    Directory of Open Access Journals (Sweden)

    WU Jin-song

    2012-12-01

    Full Text Available Intraoperative neurophysiological monitoring (IONM is the gold standard of the intraoperative functional brain mapping. It employs various electrophysiological methods such as awake craniotomy, intraoperative somatosensory and motor evoked potentials monitoring, intraoperative cortical stimulation and sub-cortical stimulation to accurately map the cortical and sub-cortical nervous pathways so that the continuous assessment and real -time protection of the functional integrity of certain neural structures can be achieved during surgery. Based on decades of clinical practice, the Department of Neurosurgery of Shanghai Huashan Hospital has set up an "IONM clinical practice guideline" used in the institute. The clinical practice guideline covers technical and operation standards of IONM in all kinds of common neurosurgery diseases and does improve the clinical efficacy in neurosurgical procedures.

  7. Intraoperative adverse events associated with extremely preterm cesarean deliveries.

    Science.gov (United States)

    Bertholdt, Charline; Menard, Sophie; Delorme, Pierre; Lamau, Marie-Charlotte; Goffinet, François; Le Ray, Camille

    2018-05-01

    At the same time as survival is increasing among premature babies born before 26 weeks of gestation, the rates of cesarean deliveries before 26 weeks is also rising. Our purpose was to compare the frequency of intraoperative adverse events during cesarean deliveries in two gestational age groups: 24-25 weeks and 26-27 weeks. This single-center retrospective cohort study included all women with cesarean deliveries performed before 28 +0 weeks from 2007 through 2015. It compared the frequency of intraoperative adverse events between two groups: those at 24-25 weeks of gestation and at 26-27 weeks. Intraoperative adverse events were a classical incision, transplacental incision, difficulty in fetal extraction (explicitly mentioned in the surgical report), postpartum hemorrhage (≥500 mL of blood loss), and injury to internal organs. A composite outcome including at least one of these events enabled us to analyze the risk factors for intraoperative adverse events with univariate and multivariable analysis. Stratified analyses by the indication for the cesarean were performed. We compared 74 cesarean deliveries at 24-25 weeks of gestation and 214 at 26-27 weeks. Intraoperative adverse events occurred at higher rates in the 24-25-week group (63.5 vs. 30.8%, p cesarean. These results should help obstetricians and women making decisions about cesarean deliveries at these extremely low gestational ages. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  8. Physics-based shape matching for intraoperative image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Suwelack, Stefan, E-mail: suwelack@kit.edu; Röhl, Sebastian; Bodenstedt, Sebastian; Reichard, Daniel; Dillmann, Rüdiger; Speidel, Stefanie [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology, Adenauerring 2, Karlsruhe 76131 (Germany); Santos, Thiago dos; Maier-Hein, Lena [Computer-assisted Interventions, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Wagner, Martin; Wünscher, Josephine; Kenngott, Hannes; Müller, Beat P. [General, Visceral and Transplantation Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 110, Heidelberg 69120 (Germany)

    2014-11-01

    Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intraoperative surface has to be matched to the preoperative model. The shape matching is especially challenging in the intraoperative setting due to noisy sensor data, only partially visible surfaces, ambiguous shape descriptors, and real-time requirements. Methods: A novel physics-based shape matching (PBSM) approach to register intraoperatively acquired surface meshes to preoperative planning data is proposed. The key idea of the method is to describe the nonrigid registration process as an electrostatic–elastic problem, where an elastic body (preoperative model) that is electrically charged slides into an oppositely charged rigid shape (intraoperative surface). It is shown that the corresponding energy functional can be efficiently solved using the finite element (FE) method. It is also demonstrated how PBSM can be combined with rigid registration schemes for robust nonrigid registration of arbitrarily aligned surfaces. Furthermore, it is shown how the approach can be combined with landmark based methods and outline its application to image guidance in laparoscopic interventions. Results: A profound analysis of the PBSM scheme based on in silico and phantom data is presented. Simulation studies on several liver models show that the approach is robust to the initial rigid registration and to parameter variations. The studies also reveal that the method achieves submillimeter registration accuracy (mean error between 0.32 and 0.46 mm). An unoptimized, single core implementation of the approach achieves near real-time performance (2 TPS, 7–19 s total registration time). It outperforms established methods in terms of speed and accuracy. Furthermore, it is shown that the

  9. Recirculatory modeling in man using Indocyanine green

    NARCIS (Netherlands)

    Reekers, Marije

    2012-01-01

    Titration to effect is the most important action anesthesiologists use to assure adequacy of anesthesia and safeguard their patients from serious side effects. For a proper titration to effect the anesthesiologist takes into consideration the historical response to a given dose to estimate the

  10. Role of scrape cytology in the intraoperative diagnosis of tumor

    Directory of Open Access Journals (Sweden)

    Kolte Sachin

    2010-01-01

    Full Text Available Background : Rapid diagnosis of surgically removed specimens has created many controversies and a single completely reliable method has not yet been developed. Histopathology of a paraffin section remains the ultimate gold standard in tissue diagnosis. Frozen section is routinely used by the surgical pathology laboratories for intraoperative diagnosis. The use of either frozen section or cytological examination alone has an acceptable rate (93-97% of correct diagnosis, with regard to interpretation of benign versus malignant. Aim : To evaluate the utility of scrape cytology for the rapid diagnosis of surgically removed tumors and its utilisation for learning cytopathology. Materials and Methods : 75 surgically removed specimens from various organs and systems were studied. Scrapings were taken from each specimen before formalin fixation and stained by modified rapid Papanicolaou staining. Results : Of the 75 cases studied, 73 could be correctly differentiated into benign and malignant tumors, with an accuracy rate of 97.3%. Conclusions : Intraoperative scrape cytology is useful for intraoperative diagnosis of tumor, where facilities for frozen section are not available. The skill and expertise developed by routinely practicing intraoperative cytology can be applied to the interpretation of fine needle aspirate smears. Thus, apart from its diagnostic role, intraoperative cytology can become a very useful learning tool in the field of cytopathology.

  11. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  12. Intraoperative ultrasound in neurosurgery

    International Nuclear Information System (INIS)

    Velasco, J.; Manzanares, R.; Fernandez, L.; Hernando, A.; Ramos, M. del Mar; Garcia, R.

    1996-01-01

    The present work is a review of the major indications for intraoperative ultrasound in the field of neurosurgery, stressing the exploratory method and describing what we consider to be the most illustrative cases. We attempt to provide a thorough view of this constantly developing technique which, despite its great practical usefulness, may be being underemployed. (Author) 47 refs

  13. Intraoperative magnetic resonance imaging during surgery for pituitary adenomas: pros and cons.

    Science.gov (United States)

    Buchfelder, Michael; Schlaffer, Sven-Martin

    2012-12-01

    Surgery for pituitary adenomas still remains a mainstay in their treatment, despite all advances in sophisticated medical treatments and radiotherapy. Total tumor excision is often attempted, but there are limitations in the intraoperative assessment of the radicalism of tumor resection by the neurosurgeon. Standard postoperative imaging is usually performed with a few months delay from the surgical intervention. The purpose of this report is to review briefly the facilities and kinds of intraoperative magnetic resonance imaging for all physician and surgeons involved in the management of pituitary adenomas on the basis of current literature. To date, there are several low- and high-field magnetic resonance imaging systems available for intraoperative use and depiction of the extent of tumor removal during surgery. Recovery of vision and the morphological result of surgery can be largely predicted from the intraoperative images. A variety of studies document that depiction of residual tumor allows targeted attack of the remnant and extent the resection. Intraoperative magnetic resonance imaging offers an immediate feedback to the surgeon and is a perfect quality control for pituitary surgery. It is also used as a basis of datasets for intraoperative navigation which is particularly useful in any kind of anatomical variations and repeat operations in which primary surgery has distorted the normal anatomy. However, setting up the technology is expensive and some systems even require extensive remodeling of the operation theatre. Intraoperative imaging prolongs the operation, but may also depict evolving problems, such as hematomas in the tumor cavity. There are several artifacts in intraoperative MR images possible that must be considered. The procedures are not associated with an increased complication rate.

  14. Intraoperative definition of bottom-of-sulcus dysplasia using intraoperative ultrasound and single depth electrode recording - A technical note.

    Science.gov (United States)

    Miller, Dorothea; Carney, Patrick; Archer, John S; Fitt, Gregory J; Jackson, Graeme D; Bulluss, Kristian J

    2018-02-01

    Bottom of sulcus dysplasias (BOSDs) are localized focal cortical dysplasias (FCDs) centred on the bottom of a sulcus that can be highly epileptogenic, but difficult to delineate intraoperatively. We report on a patient with refractory epilepsy due to a BOSD, successfully resected with the aid of a multimodal surgical approach using neuronavigation based on MRI and PET, intraoperative ultrasound (iUS) and electrocorticography (ECoG) using depth electrodes. The lesion could be visualized on iUS showing an increase in echogenicity at the grey-white matter junction. IUS demonstrated the position of the depth electrode in relation to the lesion. Depth electrode recording showed almost continuous spiking. Thus, intraoperative imaging and electrophysiology helped confirm the exact location of the lesion. Post-resection ultrasound demonstrated the extent of the resection and depth electrode recording did not show any epileptiform activity. Thus, both techniques helped assess completeness of resection. The patient has been seizure free since surgery. Using a multimodal approach including iUS and ECoG is a helpful adjunct in surgery for BOSD and may improve seizure outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint.

    Science.gov (United States)

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  16. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint

    Directory of Open Access Journals (Sweden)

    Michael Woods

    2014-01-01

    Full Text Available Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  17. Disparities between resident and attending surgeon perceptions of intraoperative teaching.

    Science.gov (United States)

    Butvidas, Lynn D; Anderson, Cheryl I; Balogh, Daniel; Basson, Marc D

    2011-03-01

    This study aimed to assess attending surgeon and resident recall of good and poor intraoperative teaching experiences and how often these experiences occur at present. By web-based survey, we asked US surgeons and residents to describe their best and worst intraoperative teaching experiences during training and how often 26 common intraoperative teaching behaviors occur in their current environment. A total of 346 residents and 196 surgeons responded (51 programs; 26 states). Surgeons and residents consistently identified trainee autonomy, teacher confidence, and communication as positive, while recalling negatively contemptuous, arrogant, accusatory, or uncommunicative teachers. Residents described intraoperative teaching behaviors by faculty as substantially less frequent than faculty self-reports. Neither sex nor seniority explained these results, although women reported communicative behaviors more frequently than men. Although veteran surgeons and current trainees agree on what constitutes effective and ineffective teaching in the operating room, they disagree on how often these behaviors occur, leaving substantial room for improvement. Published by Elsevier Inc.

  18. Intra-operative radiotherapy in oncology

    International Nuclear Information System (INIS)

    Gerard, J.P.; Braillon, G.; Sentenac, I.; Calvo, F.; Dubois, J.B.; Saint-Aubert, B.; Guillemin, C.; Roussel, A.

    1991-01-01

    This article is about a treatment used more and more frequently in the world, for some neoplasms: Intra-operative radiotherapy under electron beams. The main neoplasms concerned by this treatment are the stomach, pancreas, rectum, bladder, uterus cervix neoplasms and peritoneal sarcoma [fr

  19. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  20. Intraoperative neurophysiological monitoring for the anaesthetist

    African Journals Online (AJOL)

    2012-11-15

    Nov 15, 2012 ... ... nerve tracts, and by understanding how anaesthetic agents affect the various ... of the physiologically sensitive nervous system and different ... Keywords: evoked potentials, intraoperative monitoring, brain mapping. Abstract.

  1. Near-Infrared Fluorescence Laparoscopy of the Cystic Duct and Artery in Pigs : Performance of a Preclinical Dye

    NARCIS (Netherlands)

    Schols, Rutger M.; Lodewick, Toine M.; Bouvy, Nicole D.; van Dam, Dieuwertje A.; Meijerink, Wilhelmus J. H. J.; van Dam, Gooitzen M.; Dejong, Cornelis H. C.; Stassen, Laurents P. S.

    2014-01-01

    Background: Near-infrared fluorescence laparoscopy after intravenous indocyanine green (ICG) administration has been proposed as a promising surgical imaging technique for real-time visualization of the extrahepatic bile ducts and arteries in clinical laparoscopic cholecystectomies. However,

  2. Novel techniques of real-time blood flow and functional mapping: technical note.

    Science.gov (United States)

    Kamada, Kyousuke; Ogawa, Hiroshi; Saito, Masato; Tamura, Yukie; Anei, Ryogo; Kapeller, Christoph; Hayashi, Hideaki; Prueckl, Robert; Guger, Christoph

    2014-01-01

    There are two main approaches to intraoperative monitoring in neurosurgery. One approach is related to fluorescent phenomena and the other is related to oscillatory neuronal activity. We developed novel techniques to visualize blood flow (BF) conditions in real time, based on indocyanine green videography (ICG-VG) and the electrophysiological phenomenon of high gamma activity (HGA). We investigated the use of ICG-VG in four patients with moyamoya disease and two with arteriovenous malformation (AVM), and we investigated the use of real-time HGA mapping in four patients with brain tumors who underwent lesion resection with awake craniotomy. Real-time data processing of ICG-VG was based on perfusion imaging, which generated parameters including arrival time (AT), mean transit time (MTT), and BF of brain surface vessels. During awake craniotomy, we analyzed the frequency components of brain oscillation and performed real-time HGA mapping to identify functional areas. Processed results were projected on a wireless monitor linked to the operating microscope. After revascularization for moyamoya disease, AT and BF were significantly shortened and increased, respectively, suggesting hyperperfusion. Real-time fusion images on the wireless monitor provided anatomical, BF, and functional information simultaneously, and allowed the resection of AVMs under the microscope. Real-time HGA mapping during awake craniotomy rapidly indicated the eloquent areas of motor and language function and significantly shortened the operation time. These novel techniques, which we introduced might improve the reliability of intraoperative monitoring and enable the development of rational and objective surgical strategies.

  3. Intra-operative blood transfusion among adult surgical patients in a ...

    African Journals Online (AJOL)

    This retrospective study was designed to audit the pattern of intra-operative whole blood transfusion among adult surgical patients over a two-year period. Data were collected on the rate of intra-operative transfusion, estimated blood loss, units of donor blood transfused, pattern of use of autologous blood and circumstances ...

  4. Usefulness of intraoperative ultra low-field magnetic resonance imaging in glioma surgery.

    Science.gov (United States)

    Senft, Christian; Seifert, Volker; Hermann, Elvis; Franz, Kea; Gasser, Thomas

    2008-10-01

    The aim of this study was to demonstrate the usefulness of a mobile, intraoperative 0.15-T magnetic resonance imaging (MRI) scanner in glioma surgery. We analyzed our prospectively collected database of patients with glial tumors who underwent tumor resection with the use of an intraoperative ultra low-field MRI scanner (PoleStar N-20; Odin Medical Technologies, Yokneam, Israel/Medtronic, Louisville, CO). Sixty-three patients with World Health Organization Grade II to IV tumors were included in the study. All patients were subjected to postoperative 1.5-T imaging to confirm the extent of resection. Intraoperative image quality was sufficient for navigation and resection control in both high- and low-grade tumors. Primarily enhancing tumors were best detected on T1-weighted imaging, whereas fluid-attenuated inversion recovery sequences proved best for nonenhancing tumors. Intraoperative resection control led to further tumor resection in 12 (28.6%) of 42 patients with contrast-enhancing tumors and in 10 (47.6%) of 21 patients with noncontrast-enhancing tumors. In contrast-enhancing tumors, further resection led to an increased rate of complete tumor resection (71.2 versus 52.4%), and the surgical goal of gross total removal or subtotal resection was achieved in all cases (100.0%). In patients with noncontrast-enhancing tumors, the surgical goal was achieved in 19 (90.5%) of 21 cases, as intraoperative MRI findings were inconsistent with postoperative high-field imaging in 2 cases. The use of the PoleStar N-20 intraoperative ultra low-field MRI scanner helps to evaluate the extent of resection in glioma surgery. Further tumor resection after intraoperative scanning leads to an increased rate of complete tumor resection, especially in patients with contrast-enhancing tumors. However, in noncontrast- enhancing tumors, the intraoperative visualization of a complete resection seems less specific, when compared with postoperative 1.5-T MRI.

  5. Neuronavigation for arteriovenous malformation surgery by intraoperative three-dimensional ultrasound angiography.

    Science.gov (United States)

    Mathiesen, Tiit; Peredo, Inti; Edner, Göran; Kihlström, Lars; Svensson, Mikael; Ulfarsson, Elfar; Andersson, Tommy

    2007-04-01

    Neuronavigational devices have traditionally used preoperative imaging with limited possibilities for adjustment to brain shift and intraoperative manipulation of the surgical lesions. We have used an intraoperative imaging and navigation system that uses navigation on intraoperatively acquired three-dimensional ultrasound data, as well as preoperatively acquired magnetic resonance imaging scans and magnetic resonance angiograms. The usefulness of this system for arteriovenous malformation (AVM) surgery was evaluated prospectively. Nine consecutive patients with Spetzler Grade 1 (n = 3), 2 (n = 3), 3(n = 2) or 4 (n = 1) AVMs underwent operation using this intraoperative imaging and navigation system. The system provides real-time rendering of three-dimensional angiographic data and can visualize such projections in a stereoscopic (virtual reality) manner using special glasses. The experiences with this technology were analyzed and the outcomes assessed. Angiographic reconstructions of three-dimensional images were obtained before and after resection. Conventional navigation on the basis of preoperative magnetic resonance angiography was helpful to secure positioning of the bone flap; stereoscopic visualization of the same data represented a powerful means to construct a mental three-dimensional picture of the extent of the AVM and the feeder anatomy even before skin incision. Intraoperative ultrasound corresponded well to the intraoperative findings and allowed confirmation of feeding vessels in surrounding gyri and rapid identification of the perinidal dissection planes, regardless of brain shift. The latter feature was particularly helpful because the intraoperative navigational identification of surgical planes leads to minimal exploration into the nidus or dissection at a greater distance from the malformation. Application of the system was thought to increase surgical confidence. In two patients, postresection ultrasound prompted additional nidus removal

  6. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    Science.gov (United States)

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as

  7. Intraoperative mapping of expressive language cortex using passive real-time electrocorticography

    Directory of Open Access Journals (Sweden)

    AmiLyn M. Taplin

    2016-01-01

    Full Text Available In this case report, we investigated the utility and practicality of passive intraoperative functional mapping of expressive language cortex using high-resolution electrocorticography (ECoG. The patient presented here experienced new-onset seizures caused by a medium-grade tumor in very close proximity to expressive language regions. In preparation of tumor resection, the patient underwent multiple functional language mapping procedures. We examined the relationship of results obtained with intraoperative high-resolution ECoG, extraoperative ECoG utilizing a conventional subdural grid, extraoperative electrical cortical stimulation (ECS mapping, and functional magnetic resonance imaging (fMRI. Our results demonstrate that intraoperative mapping using high-resolution ECoG is feasible and, within minutes, produces results that are qualitatively concordant to those achieved by extraoperative mapping modalities. They also suggest that functional language mapping of expressive language areas with ECoG may prove useful in many intraoperative conditions given its time efficiency and safety. Finally, they demonstrate that integration of results from multiple functional mapping techniques, both intraoperative and extraoperative, may serve to improve the confidence in or precision of functional localization when pathology encroaches upon eloquent language cortex.

  8. Dacryocystorhinostomy without intubation with intraoperative mitomycin-c

    International Nuclear Information System (INIS)

    Rahman, A.; Channa, S.; Memon, M.S.; Niazi, J.H.

    2006-01-01

    To evaluate the success rate and complications of intraoperative Mitomycin-C in dacryocystorhinostomy surgery. This study included total 90 eyes of 90 patients fulfilling the inclusion criteria.The surgical procedure of external DCR done with intraoperative Mitomycin-C with a neurosurgical cottonoid soaked with 0.2mg/ml. Mitomycin C was applied to the anastomosed flaps and osteotomy site for 10 minutes, without Silicon tube intubation. Surgery was done under local as well as general anesthesia. Patients were followed for 6 months. Out of 90 patients included in this study, only 2 patients complained of persistent epiphora after 6 months follow-up and were labeled as failed DCR. Remaining 88 had either no tearing or significant improvement of tearing after 6 months follow up and patent lacrimal system by syringing without pressure. Success rate in this procedure was 97.77% (p-value< 0.001). This study showed very high rate of success. Only complication noted was excessive nasal bleeding which was easily controlled. Intraoperative Mitomycin-C application in external DCR is safe, effective, cheap adjunct that helps to achieve good results of DCR surgery. (author)

  9. Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK.

    Science.gov (United States)

    Narváez, Julio; Brucks, Matthew; Zimmerman, Grenith; Bekendam, Peter; Bacon, Gregory; Schmid, Kristin

    2012-05-01

    To determine the degree of cyclorotation and centroid shift in the x and y axis that occurs intraoperatively during LASIK and photorefractive keratectomy (PRK). Intraoperative cyclorotation and centroid shift were measured in 63 eyes from 34 patients with a mean age of 34 years (range: 20 to 56 years) undergoing either LASIK or PRK. Preoperatively, an iris image of each eye was obtained with the VISX WaveScan Wavefront System (Abbott Medical Optics Inc) with iris registration. A VISX Star S4 (Abbott Medical Optics Inc) laser was later used to measure cyclotorsion and pupil centroid shift at the beginning of the refractive procedure and after flap creation or epithelial removal. The mean change in intraoperative cyclorotation was 1.48±1.11° in LASIK eyes and 2.02±2.63° in PRK eyes. Cyclorotation direction changed by >2° in 21% of eyes after flap creation in LASIK and in 32% of eyes after epithelial removal in PRK. The respective mean intraoperative shift in the x axis and y axis was 0.13±0.15 mm and 0.17±0.14 mm, respectively, in LASIK eyes, and 0.09±0.07 mm and 0.10±0.13 mm, respectively, in PRK eyes. Intraoperative centroid shifts >100 μm in either the x axis or y axis occurred in 71% of LASIK eyes and 55% of PRK eyes. Significant changes in cyclotorsion and centroid shifts were noted prior to surgery as well as intraoperatively with both LASIK and PRK. It may be advantageous to engage iris registration immediately prior to ablation to provide a reference point representative of eye position at the initiation of laser delivery. Copyright 2012, SLACK Incorporated.

  10. Intraoperative language localization in multilingual patients with gliomas.

    Science.gov (United States)

    Bello, Lorenzo; Acerbi, Francesco; Giussani, Carlo; Baratta, Pietro; Taccone, Paolo; Songa, Valeria; Fava, Marica; Stocchetti, Nino; Papagno, Costanza; Gaini, Sergio M

    2006-07-01

    Intraoperative localization of speech is problematic in patients who are fluent in different languages. Previous studies have generated various results depending on the series of patients studied, the type of language, and the sensitivity of the tasks applied. It is not clear whether languages are mediated by multiple and separate cortical areas or shared by common areas. Globally considered, previous studies recommended performing a multiple intraoperative mapping for all the languages in which the patient is fluent. The aim of this work was to study the feasibility of performing an intraoperative multiple language mapping in a group of multilingual patients with a glioma undergoing awake craniotomy for tumor removal and to describe the intraoperative cortical and subcortical findings in the area of craniotomy, with the final goal to maximally preserve patients' functional language. Seven late, highly proficient multilingual patients with a left frontal glioma were submitted preoperatively to a battery of tests to evaluate oral language production, comprehension, and repetition. Each language was tested serially starting from the first acquired language. Items that were correctly named during these tests were used to build personalized blocks to be used intraoperatively. Language mapping was undertaken during awake craniotomies by the use of an Ojemann cortical stimulator during counting and oral naming tasks. Subcortical stimulation by using the same current threshold was applied during tumor resection, in a back and forth fashion, and the same tests. Cortical sites essential for oral naming were found in 87.5% of patients, those for the first acquired language in one to four sites, those for the other languages in one to three sites. Sites for each language were distinct and separate. Number and location of sites were not predictable, being randomly and widely distributed in the cortex around or less frequently over the tumor area. Subcortical stimulations found

  11. The Art of Intraoperative Glioma Identification

    Directory of Open Access Journals (Sweden)

    Zoe Z Zhang

    2015-07-01

    Full Text Available A major dilemma in brain tumor surgery is the identification of tumor boundaries to maximize tumor excision and minimize postoperative neurological damage. Gliomas, especially low-grade tumors, and normal brain have a similar color and texture which poses a challenge to the neurosurgeon. Advances in glioma resection techniques combine the experience of the neurosurgeon and various advanced technologies. Intraoperative methods to delineate gliomas from normal tissue consist of 1 image-based navigation, 2 intraoperative sampling, 3 electrophysiological monitoring, and 4 enhanced visual tumor demarcation. The advantages and disadvantages of each technique are discussed. A combination of these methods is becoming widely accepted in routine glioma surgery. Gross total resection in conjunction with radiation, chemotherapy, or immune/gene therapy may increase the rates of cure in this devastating disease.

  12. Green Transformational Leadership and Green Performance: The Mediation Effects of Green Mindfulness and Green Self-Efficacy

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2014-09-01

    Full Text Available No prior literature explores the influence of green transformational leadership on green performance, thus, this study develops a novel research framework to fill the research gap. This study investigates the influence of green transformational leadership on green performance and discusses the mediation effects of green mindfulness and green self-efficacy by means of structural equation modeling (SEM. The results indicate that green transformational leadership positively influences green mindfulness, green self-efficacy, and green performance. Moreover, this study demonstrates that the positive relationship between green transformational leadership and green performance is partially mediated by the two mediators: green mindfulness and green self-efficacy. It means that green transformational leadership can not only directly affect green performance positively but also indirectly affect it positively through green mindfulness and green self-efficacy. Therefore, firms need to raise their green transformational leadership, green mindfulness, and green self-efficacy to increase their green performance.

  13. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  14. Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zauls, A. Jason; Ashenafi, Michael S. [Department of Radiation Oncology, Hollings Cancer Center, Medical University of South Carolina, Charleston, SC (United States); Onicescu, Georgiana [Department of Biostatistics and Epidemiology, Hollings Cancer Center, Medical University of South Carolina, Charleston, SC (United States); Clarke, Harry S. [Department of Urology, Hollings Cancer Center, Medical University of South Carolina, Charleston, SC (United States); Marshall, David T., E-mail: marshadt@musc.edu [Department of Radiation Oncology, Hollings Cancer Center, Medical University of South Carolina, Charleston, SC (United States)

    2011-11-15

    Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method, the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.

  15. Pancreatectomy with intraoperative radiotherapy for pancreatic cancer. Implications of adjuvant radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hishinuma, Shoichi; Ogata, Yoshiro; Ozawa, Iwao; Matsui, Junichi [Tochigi Cancer Center (Japan)

    1999-06-01

    Implications of adjuvant radiotherapy (intraoperative and postoperative) for pancreatic carcinoma were investigated. In the examination of autopsy, it was confirmed that local recurrence was controlled by irradiation, but frequency of local recurrence and liver metastasis was high, and the prognosis was poor. Local recurrence rate was 13.3% in 15 cases which had intraoperative irradiation of 30 Gy and 40% in 10 cases of irradiation under 30 Gy. After 1994, postoperative irradiation for whole liver was added to local intraoperative irradiation, and good results were obtained (10 of 19 cases are alive). Liver metastasis rate was 21.1% in whole liver irradiation group, and about 50% in other groups. Recently, local intraoperative irradiation of 30 Gy with whole liver irradiation of 22 Gy was adopted as standard adjuvant radiotherapy and better results were obtained. But it is too early to conclude their effects. (K.H.)

  16. Pancreatectomy with intraoperative radiotherapy for pancreatic cancer. Implications of adjuvant radiotherapy

    International Nuclear Information System (INIS)

    Hishinuma, Shoichi; Ogata, Yoshiro; Ozawa, Iwao; Matsui, Junichi

    1999-01-01

    Implications of adjuvant radiotherapy (intraoperative and postoperative) for pancreatic carcinoma were investigated. In the examination of autopsy, it was confirmed that local recurrence was controlled by irradiation, but frequency of local recurrence and liver metastasis was high, and the prognosis was poor. Local recurrence rate was 13.3% in 15 cases which had intraoperative irradiation of 30 Gy and 40% in 10 cases of irradiation under 30 Gy. After 1994, postoperative irradiation for whole liver was added to local intraoperative irradiation, and good results were obtained (10 of 19 cases are alive). Liver metastasis rate was 21.1% in whole liver irradiation group, and about 50% in other groups. Recently, local intraoperative irradiation of 30 Gy with whole liver irradiation of 22 Gy was adopted as standard adjuvant radiotherapy and better results were obtained. But it is too early to conclude their effects. (K.H.)

  17. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    Science.gov (United States)

    Lee, Su-Keon; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondylolisthesis on lumbar lordosis after an intraoperative prone position. Methods Sixty-seven patients, who underwent spinal fusion at the Department of Orthopaedic Surgery of Gwangmyeong Sungae Hospital between May 2007 and February 2012, were included in this study. The study compared lumbar lordosis on preoperative upright, intraoperative prone and postoperative upright lateral X-rays between the simple stenosis (SS) group and spondylolisthesis group. The average age of patients was 67.86 years old. The average preoperative lordosis was 43.5° (± 14.9°), average intraoperative lordosis was 48.8° (± 13.2°), average postoperative lordosis was 46.5° (± 16.1°) and the average change on the frame was 5.3° (± 10.6°). Results Among all patients, 24 patients were diagnosed with simple spinal stenosis, 43 patients with spondylolisthesis (29 degenerative spondylolisthesis and 14 isthmic spondylolisthesis). Between the SS group and spondylolisthesis group, preoperative lordosis, intraoperative lordosis and postoperative lordosis were significantly larger in the spondylolisthesis group. The ratio of patients with increased lordosis on the OSI frame compared to preoperative lordosis was significantly higher in the spondylolisthesis group. The risk of increased lordosis on frame was significantly higher in the spondylolisthesis group (odds ratio, 3.325; 95% confidence interval, 1.101 to 10.039; p = 0.033). Conclusions Intraoperative lumbar lordosis on the OSI frame with a prone

  18. Biomcompatible gold nanorods conjugated with photosensitizers assisted for photostability and photodestructive ability

    Science.gov (United States)

    Kuo, Wen-Shuo; Chen, Shean-Jen

    2012-02-01

    Light-exposure-mediated higher temperatures that markedly accelerate the degradation of indocyanine green (ICG) in aqueous solutions by thermal decomposition have been a serious medical problem. In this work, we present the example of using gold nanorods (Au NRs) simultaneously serving as photodynamic and photothermal agents to destroy malignant cells. Au NRs were successfully conjugated with hydrophilic photosensitizer, indocyanine green (ICG), to achieve photodynamic therapy (PDT) and photothermal therapy (PTT). We also demonstrated that Au NRs conjugated with ICG displayed high chemical stability and acted as a promising diagnostic probe. Due to its stability even via higher temperatures mediated by laser irradiation, the combination of PDT and PTT proved to be efficiently killing cancer cells as compared to PDT or PTT treatment alone and enhanced the effectiveness of photodestruction and was demonstrated to enhance its photostability.

  19. Categorization of intraoperative ureteroscopy complications using modified Satava classification system.

    Science.gov (United States)

    Tepeler, Abdulkadir; Resorlu, Berkan; Sahin, Tolga; Sarikaya, Selcuk; Bayindir, Mirze; Oguz, Ural; Armagan, Abdullah; Unsal, Ali

    2014-02-01

    To review our experience with ureteroscopy (URS) in the treatment of ureteral calculi and stratify intraoperative complications of URS according to the modified Satava classification system. We performed a retrospective analysis of 1,208 patients (672 males and 536 females), with a mean age of 43.1 years (range 1-78), who underwent ureteroscopic procedures for removal of ureteral stones. Intraoperative complications were recorded according to modified Satava classification system. Grade 1 complications included incidents without consequences for the patient; grade 2 complications, which are treated intraoperatively with endoscopic surgery (grade 2a) or required endoscopic re-treatment (grade 2b); and grade 3 complications included incidents requiring open or laparoscopic surgery. The stones were completely removed in 1,067 (88.3%) patients after primary procedure by either simple extraction or after fragmentation. The overall incidence of intraoperative complications was 12.6%. The most common complications were proximal stone migration (3.9%), mucosal injury (2.8%), bleeding (1.9%), inability to reach stone (1.8%), malfunctioning or breakage of instruments (0.8%), ureteral perforation (0.8%) and ureteral avulsion (0.16%). According to modified Satava classification system, there were 4.5% grade 1; 4.4% grade 2a; 3.2% grade 2b; and 0.57% grade 3 complications. We think that modified Satava classification is a quick and simple system for describing the severity of intraoperative URS complications and this grading system will facilitate a better comparison for the surgical outcomes obtained from different centers.

  20. Intraoperative and early postoperative complications of manual sutureless cataract extraction.

    Science.gov (United States)

    Iqbal, Yasir; Zia, Sohail; Baig Mirza, Aneeq Ullah

    2014-04-01

    To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Case series. Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema.

  1. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  2. Experimental and clinical studies with intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Kinsella, T.; Tepper, J.; Travis, E.L.; Rosenberg, S.A.; Glatstein, E.

    1983-01-01

    Studies of normal tissue tolerance to intraoperative radiotherapy were done upon 65 dogs subjected to laparotomy and 11 million electron volt electron irradiation in doses ranging from zero to 5,000 rads. Results of studies indicated that intact aorta and vena cava tolerate up to 5,000 rads without loss of structural integrity. Ureteral fibrosis and stenosis develop at doses of 3,000 rads or more. Arterial anastomoses heal after doses of 4,500 rads, but fibrosis can lead to occlusion. Intestinal suture lines heal after doses of 4,500 rads. Bile duct fibrosis and stenosis develop at doses of 2,000 rads or more. Biliary-enteric anastomoses fail to heal at any dose level. A clinical trial of intraoperative radiotherapy combined with radical surgery was performed upon 20 patients with advanced malignant tumors which were considered unlikely to be cured by conventional therapies and which included carcinomas of the stomach, carcinomas of the pancreas, carcinomas involving the hilus of the liver, retroperitoneal sarcomas and osteosarcomas of the pelvis. All patients underwent resection of gross tumor, followed by intraoperative irradiation of the tumor bed and regional nodal basins. Some patients received additional postoperative external beam radiotherapy. Treatment mortality for combined operation and radiotherapy occurred in four of 20 patients. Postoperative complications occurred in four of the 16 surviving patients. Local tumor control was achieved in 11 of the 16 surviving patients, with an over-all median follow-up period of 18 months. The clinical trial suggested that intraoperative radiotherapy is a feasible adjunct to resection in locally advanced tumors, that the resulting mortality and morbidity is similar to that expected from operation alone and that local tumor control may be improved

  3. Intraoperative dynamic dosimetry for prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D A [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zaider, M [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Cohen, G N [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Worman, M F [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zelefsky, M J [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States)

    2003-05-07

    This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer - a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications - if necessary - still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

  4. Intraoperative radiotherapy for the treatment of gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Satomura, Kisaku; Inamoto, Shun; Honda, Kazuo; Takahashi, Masaji [Kyoto Univ. (Japan). Faculty of Medicine

    1982-12-01

    Clinical results of intraoperative radiotherapy for gastric cancer were reported. One hundred and five cases of gastric cancer were treated by intraoperative radiotherapy. Whatever the stage of the patient was, 3-year survival rate was found to be better in the radiotherapy group than that of the control group (treated surgical resection only). Five year survival rate of the stages III and IV in the radiotherapy group was better than the control group. Unfavorable side effects were observed in 4 cases out of 105 cases. In one case, penetration of postoperative peptic ulcer into the irradiated aortic wall was found by autopsy. Two cases of bile duct stenosis and one case of ileus due to acutely developed peritonitis carcinomatosa were experienced. In conclusion, intraoperative radiotherapy immediately after surgical resection for the treatment of gastric cancer was found to be an effective method. The most effective application of the method appears to be to cases of stage II and III without liver metastasis and peritoneal disseminations (H/sub 0/P/sub 0/, M, A).

  5. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (United States)

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    Science.gov (United States)

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  7. Prevention of intraoperative cerebrospinal fluid leaks by lumbar cerebrospinal fluid drainage during surgery for pituitary macroadenomas.

    Science.gov (United States)

    Mehta, Gautam U; Oldfield, Edward H

    2012-06-01

    Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p drainage reduced the need for operative repair (from 32% to 5%, p drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.

  8. Intraoperative tractography and neuronavigation of the pyramidal tract

    International Nuclear Information System (INIS)

    Nimsky, C.; Ganslandt, O.; Weigel, D.; Keller, B. von; Stadlbauer, A.; Akutsu, H.; Hammen, T.; Buchfelder, M.

    2008-01-01

    Diffusion tensor imaging (DTI) based fiber tracking was applied to visualize the course of the pyramidal tract in the surgical field by microscope-based navigation. In 70 patients with lesions adjacent to the pyramidal tract, DTI data were integrated in a navigational setup. Diffusion data (b=0) were rigidly registered with standard T1-weighted 3-D images. Fiber tracking was performed applying a tensor-deflection algorithm using a multiple volume of interest approach as seed regions for tracking. fMRI data identifying the motor gyrus were applied as selection criteria to define the fibers of interest. After tracking, a 3-D object was generated representing the pyramidal tract. In selected cases, the intraoperative image data (1.5 T intraoperative MRI) were used to update the navigation system. In all patients the pyramidal tract could be visualized in the operative field applying the heads-up display of the operating microscope. In 8 patients (11%) a new or aggravated postoperative paresis could be observed, which was transient in 5 of them; thus, only in 3 patients (4.2%) was there a new permanent neurological deficit. Intraoperative imaging depicted a shifting of the pyramidal tract which amounted up to 15 mm; even the direction of shifting was variable and could not be predicted before surgery, so that mathematical models trying to predict brain shift behaviour are of restricted value only. DTI fiber tracking data can be reliably integrated into navigational systems providing intraoperative visualization of the pyramidal tract. This technique allowed the resection of lesions adjacent to the pyramidal tract with low morbidity. (author)

  9. Intraoperative use of low-dose recombinant activated factor VII during thoracic aortic operations.

    Science.gov (United States)

    Andersen, Nicholas D; Bhattacharya, Syamal D; Williams, Judson B; Fosbol, Emil L; Lockhart, Evelyn L; Patel, Mayur B; Gaca, Jeffrey G; Welsby, Ian J; Hughes, G Chad

    2012-06-01

    Numerous studies have supported the effectiveness of recombinant activated factor VII (rFVIIa) for the control of bleeding after cardiac procedures; however safety concerns persist. Here we report the novel use of intraoperative low-dose rFVIIa in thoracic aortic operations, a strategy intended to improve safety by minimizing rFVIIa exposure. Between July 2005 and December 2010, 425 consecutive patients at a single referral center underwent thoracic aortic operations with cardiopulmonary bypass (CPB); 77 of these patients received intraoperative low-dose rFVIIa (≤60 μg/kg) for severe coagulopathy after CPB. Propensity matching produced a cohort of 88 patients (44 received intraoperative low-dose rFVIIa and 44 controls) for comparison. Matched patients receiving intraoperative low-dose rFVIIa got an initial median dose of 32 μg/kg (interquartile range [IQR], 16-43 μg/kg) rFVIIa given 51 minutes (42-67 minutes) after separation from CPB. Patients receiving intraoperative low-dose rFVIIa demonstrated improved postoperative coagulation measurements (partial thromboplastin time 28.6 versus 31.5 seconds; p=0.05; international normalized ratio, 0.8 versus 1.2; pproduct transfusions (2.5 versus 5.0 units; p=0.05) compared with control patients. No patient receiving intraoperative low-dose rFVIIa required postoperative rFVIIa administration or reexploration for bleeding. Rates of stroke, thromboembolism, myocardial infarction, and other adverse events were equivalent between groups. Intraoperative low-dose rFVIIa led to improved postoperative hemostasis with no apparent increase in adverse events. Intraoperative rFVIIa administration in appropriately selected patients may correct coagulopathy early in the course of refractory blood loss and lead to improved safety through the use of smaller rFVIIa doses. Appropriately powered randomized studies are necessary to confirm the safety and efficacy of this approach. Copyright © 2012 The Society of Thoracic Surgeons

  10. Advanced detection strategies for ultrasound contrast agents

    NARCIS (Netherlands)

    J.M.G. Borsboom (Jerome)

    2005-01-01

    markdownabstract__Abstract__ Ultrasound contrast agent was discovered serendipitously by Gramiak and Shah in I968 when they injected indocyanine green dye into the heart and observed increased echogenicity of the blood containing the dye. Small cavitation bubbles that were formed upon

  11. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  12. Medical Error Avoidance in Intraoperative Neurophysiological Monitoring: The Communication Imperative.

    Science.gov (United States)

    Skinner, Stan; Holdefer, Robert; McAuliffe, John J; Sala, Francesco

    2017-11-01

    Error avoidance in medicine follows similar rules that apply within the design and operation of other complex systems. The error-reduction concepts that best fit the conduct of testing during intraoperative neuromonitoring are forgiving design (reversibility of signal loss to avoid/prevent injury) and system redundancy (reduction of false reports by the multiplication of the error rate of tests independently assessing the same structure). However, error reduction in intraoperative neuromonitoring is complicated by the dichotomous roles (and biases) of the neurophysiologist (test recording and interpretation) and surgeon (intervention). This "interventional cascade" can be given as follows: test → interpretation → communication → intervention → outcome. Observational and controlled trials within operating rooms demonstrate that optimized communication, collaboration, and situational awareness result in fewer errors. Well-functioning operating room collaboration depends on familiarity and trust among colleagues. Checklists represent one method to initially enhance communication and avoid obvious errors. All intraoperative neuromonitoring supervisors should strive to use sufficient means to secure situational awareness and trusted communication/collaboration. Face-to-face audiovisual teleconnections may help repair deficiencies when a particular practice model disallows personal operating room availability. All supervising intraoperative neurophysiologists need to reject an insular or deferential or distant mindset.

  13. Intraoperative neurophysiological monitoring for the anaesthetist ...

    African Journals Online (AJOL)

    Intraoperative neurophysiological monitoring (IONM) has become the gold standard for the monitoring of functional nervous tissue and mapping of eloquent brain tissue during neurosurgical procedures. The multimodal use of somatosensory-evoked potentials and motor-evoked potentials ensures adequate monitoring of ...

  14. Pygopagus Conjoined Twins: A Neurophysiologic Intraoperative Monitoring Schema.

    Science.gov (United States)

    Cromeens, Barrett P; McKinney, Jennifer L; Leonard, Jeffrey R; Governale, Lance S; Brown, Judy L; Henry, Christina M; Levitt, Marc A; Wood, Richard J; Besner, Gail E; Islam, Monica P

    2017-03-01

    Conjoined twins occur in up to 1 in 50,000 live births with approximately 18% joined in a pygopagus configuration at the buttocks. Twins with this configuration display symptoms and carry surgical risks during separation related to the extent of their connection which can include anorectal, genitourinary, vertebral, and neural structures. Neurophysiologic intraoperative monitoring for these cases has been discussed in the literature with variable utility. The authors present a case of pygopagus twins with fused spinal cords and imperforate anus where the use of neurophysiologic intraoperative monitoring significantly impacted surgical decision-making in division of these critical structures.

  15. Intraoperative and Early Postoperative Complications of Manual Sutureless Cataract Extraction

    International Nuclear Information System (INIS)

    Iqbal, Y.; Zia, S.; Mirza, A. B.

    2014-01-01

    Objective: To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Study Design: Case series. Place and Duration of Study: Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Methodology: Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Results: Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Conclusion: Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema. (author)

  16. Preparing Platelet-Rich Plasma with Whole Blood Harvested Intraoperatively During Spinal Fusion.

    Science.gov (United States)

    Shen, Bin; Zhang, Zheng; Zhou, Ning-Feng; Huang, Yu-Feng; Bao, Yu-Jie; Wu, De-Sheng; Zhang, Ya-Dong

    2017-07-22

    BACKGROUND Platelet-rich plasma (PRP) has gained growing popularity in use in spinal fusion procedures in the last decade. Substantial intraoperative blood loss is frequently accompanied with spinal fusion, and it is unknown whether blood harvested intraoperatively qualifies for PRP preparation. MATERIAL AND METHODS Whole blood was harvested intraoperatively and venous blood was collected by venipuncture. Then, we investigated the platelet concentrations in whole blood and PRP, the concentration of growth factors in PRP, and the effects of PRP on the proliferation and viability of human bone marrow-derived mesenchymal stem cells (HBMSCs). RESULTS Our results revealed that intraoperatively harvested whole blood and whole blood collected by venipuncture were similar in platelet concentration. In addition, PRP formulations prepared from both kinds of whole blood were similar in concentration of platelet and growth factors. Additional analysis showed that the similar concentrations of growth factors resulted from the similar platelet concentrations of whole blood and PRP between the two groups. Moreover, these two kinds of PRP formulations had similar effects on promoting cell proliferation and enhancing cell viability. CONCLUSIONS Therefore, intraoperatively harvested whole blood may be a potential option for preparing PRP spinal fusion.

  17. Intraoperative Tension Pneumothorax in a Patient With Remote Trauma and Previous Tracheostomy

    Directory of Open Access Journals (Sweden)

    Ana Mavarez-Martinez MD

    2016-02-01

    Full Text Available Many trauma patients present with a combination of cranial and thoracic injury. Anesthesia for these patients carries the risk of intraoperative hemodynamic instability and respiratory complications during mechanical ventilation. Massive air leakage through a lacerated lung will result in inadequate ventilation and hypoxemia and, if left undiagnosed, may significantly compromise the hemodynamic function and create a life-threatening situation. Even though these complications are more characteristic for the early phase of trauma management, in some cases, such a scenario may develop even months after the initial trauma. We report a case of a 25-year-old patient with remote thoracic trauma, who developed an intraoperative tension pneumothorax and hemodynamic instability while undergoing an elective cranioplasty. The intraoperative patient assessment was made even more challenging by unexpected massive blood loss from the surgical site. Timely recognition and management of intraoperative pneumothorax along with adequate blood replacement stabilized the patient and helped avoid an unfavorable outcome. This case highlights the risks of intraoperative pneumothorax in trauma patients, which may develop even months after injury. A high index of suspicion and timely decompression can be life saving in this type of situation.

  18. Temporary Intraoperative Porto-Caval Shunts in Piggy-Back Liver Transplantation Reduce Intraoperative Blood Loss and Improve Postoperative Transaminases and Renal Function: A Meta-Analysis.

    Science.gov (United States)

    Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K

    2016-12-01

    The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.

  19. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve : Histopathological and morphometric studies

    NARCIS (Netherlands)

    Vujaskovic, Z; Powers, BE; Paardekoper, G; Gillette, SM; Gillette, EL; Colacchio, TA

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate

  20. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    OpenAIRE

    Lee, Su-Keon; Lee, Seung-Hwan; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondyloli...

  1. Numerical Characterization of Intraoperative and Chronic Electrodes in Deep Brain Stimulation

    Directory of Open Access Journals (Sweden)

    Alessandra ePaffi

    2015-02-01

    Full Text Available Intraoperative electrode is used in the Deep Brain stimulation (DBS technique to pinpoint the brain target and to choose the best parameters for the stimulating signal. However, when the intraoperative electrode is replaced with the chronic one, the observed effects do not always coincide with predictions.To investigate the causes of such discrepancies, in this work, a 3D model of the basal ganglia has been considered and realistic models of both intraoperative and chronic electrodes have been developed and numerically solved.Results of simulations on the electric potential and the activating function along neuronal fibers show that the different geometries and sizes of the two electrodes do not change shapes and polarities of these functions, but only the amplitudes. A similar effect is caused by the presence of different tissue layers (edema or glial tissue in the peri-electrode space. On the contrary, a not accurate positioning of the chronic electrode with respect to the intraoperative one (electric centers not coincident may induce a complete different electric stimulation on some groups of fibers.

  2. Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy

    Directory of Open Access Journals (Sweden)

    Bub-Se Na

    2017-10-01

    Full Text Available Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for completion pneumonectomy. This case serves as an example of intraoperative recurrent laryngeal nerve monitoring during thoracic surgery and supports this indication for its use.

  3. Green Transformational Leadership and Green Performance: The Mediation Effects of Green Mindfulness and Green Self-Efficacy

    OpenAIRE

    Yu-Shan Chen; Ching-Hsun Chang; Yu-Hsien Lin

    2014-01-01

    No prior literature explores the influence of green transformational leadership on green performance, thus, this study develops a novel research framework to fill the research gap. This study investigates the influence of green transformational leadership on green performance and discusses the mediation effects of green mindfulness and green self-efficacy by means of structural equation modeling (SEM). The results indicate that green transformational leadership positively influences green min...

  4. Alanine metabolism in acute falciparum malaria

    NARCIS (Netherlands)

    Pukrittayakamee, S.; Krishna, S.; ter Kuile, F.; Wilaiwan, O.; Williamson, D. H.; White, N. J.

    2002-01-01

    We investigated the integrity of the gluconeogenic pathway in severe malaria using alanine metabolism as a measure. Alanine disposition and liver blood flow, assessed by indocyanine green (ICG) clearance, were measured simultaneously in 10 patients with falciparum malaria (six severe and four

  5. Role of Intraoperative Radiographs in the Surgical Treatment of Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Queinnec, Steffen; Mazda, Keyvan

    2016-03-01

    One of the main goals of scoliosis surgery is to obtain a balanced fused spine. Although preoperative planning remains essential, intraoperative posteroanterior radiographs are the only available tool during the procedure to verify shoulder and coronal spinal balance and, if necessary, adjust the construct. The aim of this study was to quantify the direct influence of intraoperative radiographs on the surgical procedure itself during correction of adolescent idiopathic scoliosis. Retrospective analysis of prospectively collected data on a monocentric cohort of adolescent idiopathic scoliosis patients undergoing corrective surgery. A total 148 consecutive patients operated in the same department following the same validated preoperative planning method were included in this prospective radiologic study. The mean follow-up averaged 33 months. Frontal Cobb angles, T1 tilt, shoulder tilt, iliolumbar angle, and frontal balance were measured and compared on intraoperative, early postoperative, and latest follow-up radiographs. Any intraoperative modification of the correction performed after analysis of the intraoperative radiograph were recorded. The analysis of all radiologic parameters was possible in 90.5% of the cases. In 9.5% of the cases, shoulders could not be properly distinguished. Significant modifications on the upper thoracic curve to correct T1 tilt or shoulder balance were performed in 29% of the patients, and changes at the distal levels were recorded in 19%, underlining planification imperfections. On postoperative standing radiographs, the average coronal parameters were neutral, without loss of correction at follow-up. Intraoperative radiographs remain necessary to ensure compensation of the shortcomings of the modern preoperative planification method.

  6. Outcome of renal transplantation with and without intra-operative diuretics.

    Science.gov (United States)

    Hanif, F; Macrae, A N; Littlejohn, M G; Clancy, M J; Murio, E

    2011-01-01

    This paper presents an e-survey of current clinical practice of use of intra-operative diuretics during renal transplantation in the United Kingdom and a study to compare outcome of renal transplants carried out with or without intra-operative diuretics in our centre. An e-mail questionnaire to renal transplant surgeons exploring their practice of renal transplantation with or without intra-operative diuretics, the type of a diuretic/s if used and the relevant doses. An observational study comparing the outcome of renal transplant recipients, group no-diuretics (GND, n = 80) carried out from 2004 to 2008 versus group diuretics (GD n = 69) renal transplant recipients who received intra-operative diuretics over a one year period is presented. Outcome measures were incidence of delayed graft function and a comparison of graft survival in both groups. Forty surgeons answered from 18 transplant centres with a response rate of 67%. 13 surgeons do not use diuretics. Mannitol is used by 10/40, Furosemide 6/40 and 11 surgeons use a combination of both. In comparative study there was no significant overall difference in one year graft survival of GD versus GND (N = 65/69, 94% and 75/80, 94% respectively, p = 0.08) and the incidence of delayed graft function was also comparable (16/69, 23% and 21/80, 26% respectively, p = 0.07). The donor characteristics in both groups were comparable. The study showed variation in clinical practice on the use of intra-operative diuretics in renal transplantation and it did not demonstrate that the use of diuretics can improve renal graft survival. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Intraoperative magnetic resonance imaging assessment of non-functioning pituitary adenomas during transsphenoidal surgery.

    Science.gov (United States)

    Patel, Kunal S; Yao, Yong; Wang, Renzhi; Carter, Bob S; Chen, Clark C

    2016-04-01

    To review the utility of intraoperative imaging in facilitating maximal resection of non-functioning pituitary adenomas (NFAs). We performed an exhaustive MEDLINE search, which yielded 5598 articles. Upon careful review of these studies, 31 were pertinent to the issue of interest. Nine studies examined whether intraoperative MRI (iMRI) findings correlated with the presence of residual tumor on MRI taken 3 months after surgical resection. All studies using iMRI of >0.15T showed a ≥90% concordance between iMRI and 3-month post-operative MRI findings. 24 studies (22 iMRI and 2 intraoperative CT) examined whether intraoperative imaging improved the surgeon's ability to achieve a more complete resection. The resections were carried out under microscopic magnification in 17 studies and under endoscopic visualization in 7 studies. All studies support the value of intraoperative imaging in this regard, with improved resection in 15-83% of patients. Two studies examined whether iMRI (≥0.3T) improved visualization of residual NFA when compared to endoscopic visualization. Both studies demonstrated the value of iMRI in this regard, particularly when the tumor is located lateral of the sella, in the cavernous sinus, and in the suprasellar space. The currently available literature supports the utility of intraoperative imaging in facilitating increased NFA resection, without compromising safety.

  8. Intraoperative Death During Cervical Spinal Surgery: A Retrospective Multicenter Study.

    Science.gov (United States)

    Wang, Jeffrey C; Buser, Zorica; Fish, David E; Lord, Elizabeth L; Roe, Allison K; Chatterjee, Dhananjay; Gee, Erica L; Mayer, Erik N; Yanez, Marisa Y; McBride, Owen J; Cha, Peter I; Arnold, Paul M; Fehlings, Michael G; Mroz, Thomas E; Riew, K Daniel

    2017-04-01

    A retrospective multicenter study. Routine cervical spine surgeries are typically associated with low complication rates, but serious complications can occur. Intraoperative death is a very rare complication and there is no literature on its incidence. The purpose of this study was to determine the intraoperative mortality rates and associated risk factors in patients undergoing cervical spine surgery. Twenty-one surgical centers from the AOSpine North America Clinical Research Network participated in the study. Medical records of patients who received cervical spine surgery from January 1, 2005, to December 31, 2011, were reviewed to identify occurrence of intraoperative death. A total of 258 patients across 21 centers met the inclusion criteria. Most of the surgeries were done using the anterior approach (53.9%), followed by posterior (39.1%) and circumferential (7%). Average patient age was 57.1 ± 13.2 years, and there were more male patients (54.7% male and 45.3% female). There was no case of intraoperative death. Death during cervical spine surgery is a very rare complication. In our multicenter study, there was a 0% mortality rate. Using an adequate surgical approach for patient diagnosis and comorbidities may be the reason how the occurrence of this catastrophic adverse event was prevented in our patient population.

  9. Major intraoperative complications during video-assisted thoracoscopic anatomical lung resections

    DEFF Research Database (Denmark)

    Decaluwe, Herbert; Petersen, René Horsleben; Hansen, Henrik

    2015-01-01

    OBJECTIVES: A multicentre evaluation of the frequency and nature of major intraoperative complications during video-assisted thoracoscopic (VATS) anatomical resections. METHODS: Six European centres submitted their series of consecutive anatomical lung resections with the intention to treat by VATS...... for technical reasons. In-hospital mortality was 1.4% (n = 43). Conversion to open thoracotomy was observed in 5.5% (n = 170), of whom 21.8% (n = 37) were for oncological reasons, 29.4% (n = 50) for technical reasons and 48.8% (n = 83) for complications. Vascular injuries were reported in 2.9% (n = 88) patients...... major surgery (n = 9) or immediate life-threatening complications (n = 17). Twenty-three percent of the in-hospital mortalities (n = 10/43) were related to major intraoperative complications. Eight pneumonectomies (five intraoperative and three postoperative at 0.3%) were a consequence of a major...

  10. GREEN PACKAGING, GREEN PRODUCT, GREEN ADVERTISING, PERSEPSI, DAN MINAT BELI KONSUMEN

    Directory of Open Access Journals (Sweden)

    Imam Santoso

    2016-12-01

    Full Text Available Environmental problems become one of the strategic issues in achieving global competitiveness. One of the issues is products that are made from environmental friendly materials or known as green product. Furthermore, in green products marketing, the company also uses green packaging and green advertising concept. This study aimed to analyze the effect of green packaging, green products, and green advertising on consumer perception and purchasing intention. The study was conducted in Ketawanggede Village, Lowokwaru Sub-district, Malang City. The sampling method used nonprobability accidential sampling techniques. The numbers of respondents were 113 consumers in study site. Data were collected by interview using questionnaires. The method of analysis used Generalized Structured Component Analysis (GSCA. The analysis showed that the green packaging, green products, and green advertising had positive significant influence on consumer perceptions. Meanwhile, green product and consumer perception had positive significant influence on purchasing interest, but the green packaging and green advertising has not found sufficient evidence in influencing purchasing intention.

  11. The effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Yeliz Yilmaz

    2016-08-01

    Conclusion: Preoperative Lugol solution treatment was found to be a significant independent determinant of intraoperative blood loss. Moreover, preoperative Lugol solution treatment decreased the rate of blood flow, and intraoperative blood loss during thyroidectomy.

  12. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  13. [Intraoperative magnetic resonance imaging-guided functional neuronavigation plus intraoperative neurophysiological monitoring for microsurgical resection of lesions involving hand motor area].

    Science.gov (United States)

    Miao, Xing-lu; Chen, Zhi-juan; Yang, Wei-dong; Wang, Zeng-guang; Yu, Qing; Yue, Shu-yuan; Zhang, Jian-ning

    2013-01-15

    To explore the methods and applications of intraoperative magnetic resonance imaging (iMRI)-guided functional neuronavigation plus intraoperative neurophysiological monitoring (IONM) for microsurgical resection of lesions involving hand motor area. A total of 16 patients with brain lesions adjacent to hand motor area were recruited from January 2011 to April 2012. All of them underwent neuronavigator-assisted microsurgery. Also IONM was conducted to further map hand motor area and epileptogenic focus. High-field iMRI was employed to update the anatomical and functional imaging date and verify the extent of lesion resection. Brain shifting during the functional neuronavigation was corrected by iMRI in 5 patients. Finally, total lesion resection was achieved in 13 cases and subtotal resection in 3 cases. At Months 3-12 post-operation, hand motor function improved (n = 10) or remained unchanged (n = 6). None of them had persistent neurological deficit. The postoperative seizure improvement achieved Enge II level or above in 9 cases of brain lesions complicated with secondary epilepsy. Intraoperative MRI, functional neuronavigation and neurophysiological monitoring technique are complementary in microsurgery of brain lesions involving hand motor area. Combined use of these techniques can obtain precise location of lesions and hand motor functional structures and allow a maximum resection of lesion and minimization of postoperative neurological deficits.

  14. Intraoperative Tumor Perforation is Associated with Decreased 5-Year Survival in Colon Cancer

    DEFF Research Database (Denmark)

    Bundgaard, N S; Bendtsen, V O; Ingeholm, P

    2017-01-01

    BACKGROUND: It is a widely held belief that intraoperative tumor perforation in colon cancer impairs survival and causes local recurrence, although the prognostic importance remains unclear. AIM: The aim of this study was to assess the effect of unintended intraoperative tumor perforation...... on postoperative mortality and long-term survival. MATERIAL AND METHODS: This national cohort study was based on data from a prospectively maintained nationwide colorectal cancer database. We included 16,517 colon cancer patients who were resected with curative intent from 2001 to 2012. RESULTS: Intraoperative...... tumor perforation produced a significantly impaired 5-year survival of 40% compared to 64% in non-perforated colon cancer. Intraoperative tumor perforation was an independent risk factor for death, hazard ratio 1.63 (95% confidence interval: 1.4-1.94), with a significantly increased 90-day postoperative...

  15. The combination design for open and endoscopic surgery using fluorescence molecular imaging technology

    Science.gov (United States)

    Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie

    2015-03-01

    For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors

  16. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    International Nuclear Information System (INIS)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.; Anderson, W.; Terrill, R.; Sindelar, W.F.

    1991-01-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers and perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy

  17. Safty and acute toxicities of intraoperative electron radiotherapy for patients with abdominal tumors

    International Nuclear Information System (INIS)

    Zhai Yirui; Feng Qinfu; Li Minghui

    2010-01-01

    Objective: To investigate the safety and acute toxicities of intraoperative electron radiotherapy for patients with abdominal tumors. Methods: From May 2008 to August 2009, 52 patients with abdominal tumors were treated with intraoperative electron radiotherapy, including 14 patients with breast cancer,19 with pancreatic cancer, 3 with cervical cancer, 4 with ovarian cancer, 6 with sarcoma, and 6 with other tumors. Fifteen patients were with recurrent tumors. The intraoperative radiotherapy was performed using Mobetron mobile electron accelerator, with total dose of 9 - 18 Gy. In all, 29, 4 and 19 patients received complete resection, palliative resection and surgical exploration, respectively. The complications during the operations and within 6 months after operations were graded according to Common Terminology Criteria for Adverse Events v3.0 (CTC 3.0). Results: The median duration of surgery was 190 minutes. Intraoperative complications were observed in 5 patients, including 3 with hemorrhage, 1 with hypotension,and 1 with hypoxaemia, all of which were treated conservatively. The median hospitalization time and time to take out stitches was 12 and 13 days, respectively. And the in-hospital mortality was 4% (2/52). Twenty-four patients suffered post-operative adverse events, including 3 postoperative infections. With a median follow-up time of 183 days, 20% of patients suffered from grade 3 to 5 adverse events, with hematological toxicities being the most common complication, followed by bellyache. Grade 1 and 2 toxicities which were definitely associated with intraoperative radiotherapy was 28% and 4%, respectively. None of grade 3 to 5 complications were proved to be caused by intraoperative radiotherapy. Conclusions: Intraoperative electron radiotherapy is well tolerable and could be widely used for patients with abdominal tumors, with a little longer time to take out stitches but without more morbidities and toxicities compared surgery alone. (authors)

  18. Intraoperative ultrasonography for presumed brain metastases: a case series study

    Directory of Open Access Journals (Sweden)

    Helder Picarelli

    2012-10-01

    Full Text Available Brain metastases (BM are one of the most common intracranial tumors and surgical treatment can improve both the functional outcomes and patient survival, particularly when systemic disease is controlled. Image-guided BM resection using intraoperative exams, such as intraoperative ultrasound (IOUS, can lead to better surgical results. METHODS: To evaluate the use of IOUS for BM resection, 20 consecutives patients were operated using IOUS to locate tumors, identify their anatomical relationships and surgical cavity after resection. Technical difficulties, complications, recurrence and survival rates were noted. RESULTS: IOUS proved effective for locating, determining borders and defining the anatomical relationships of BM, as well as to identify incomplete tumor resection. No complications related to IOUS were seen. CONCLUSION: IOUS is a practical supporting method for the resection of BM, but further studies comparing this method with other intraoperative exams are needed to evaluate its actual contribution and reliability.

  19. Intraoperative magnetic resonance imaging for neurosurgery – An anaesthesiologist's challenge

    Directory of Open Access Journals (Sweden)

    Rajashree U Gandhe

    2018-01-01

    Full Text Available Intraoperative magnetic resonance imaging (MRI-guided neurosurgery has gained popularity over the years globally. These surgeries require a dedicated operating room and MRI-compatible anaesthesia equipment. The anaesthesiologist providing care in this setup needs to be experienced and vigilant to ensure patient safety. Strict adherence to MRI safety checklists and regular personnel training would avoid potential accidents and life-threatening emergencies. Teamwork, good communication, preprocedure planning, and familiarity with the surroundings are very important for safe care and good outcomes. We performed a literature search in Google Scholar, PubMed and Cochrane databases for original and reviewed articles for the origins, development and applications of intraoperative MRI in neurosurgical procedures. Much of the research has emphasised on the surgical indications than the anaesthetic challenges faced during intraoperative MRI guided surgery. The purpose of this review is to discuss the anaesthetic concerns specific to this unique environment.

  20. Intraoperative positioning of the hindfoot with the hindfoot alignment guide: a pilot study.

    Science.gov (United States)

    Frigg, Arno; Jud, Lukas; Valderrabano, Victor

    2014-01-01

    In a previous study, intraoperative positioning of the hindfoot by visual means resulted in the wrong varus/valgus position by 8 degrees and a relatively large standard deviation of 8 degrees. Thus, new intraoperative means are needed to improve the precision of hindfoot surgery. We therefore sought a hindfoot alignment guide that would be as simple as the alignment guides used in total knee arthroplasty. A novel hindfoot alignment guide (HA guide) has been developed that projects the mechanical axis from the tibia down to the heel. The HA guide enables the positioning of the hindfoot in the desired varus/valgus position and in plantigrade position in the lateral plane. The HA guide was used intraoperatively from May through November 2011 in 11 complex patients with simultaneous correction of the supramalleolar, tibiotalar, and inframalleolar alignment. Pre- and postoperative Saltzman views were taken and the position was measured. The HA guide significantly improved the intraoperative positioning compared with visual means: The accuracy with the HA guide was 4.5 ± 5.1 degrees (mean ± standard deviation) and without the HA guide 9.4 ± 5.5 degrees (P guide (2 avoided osteotomies, 5 additional osteotomies). The HA guide helped to position the hindfoot intraoperatively with greater precision than visual means. The HA guide was especially useful for multilevel corrections in which the need for and the amount of a simultaneous osteotomy had to be evaluated intraoperatively. Level IV, case series.

  1. Tumor location and IDH1 mutation may predict intraoperative seizures during awake craniotomy.

    Science.gov (United States)

    Gonen, Tal; Grossman, Rachel; Sitt, Razi; Nossek, Erez; Yanaki, Raneen; Cagnano, Emanuela; Korn, Akiva; Hayat, Daniel; Ram, Zvi

    2014-11-01

    Intraoperative seizures during awake craniotomy may interfere with patients' ability to cooperate throughout the procedure, and it may affect their outcome. The authors have assessed the occurrence of intraoperative seizures during awake craniotomy in regard to tumor location and the isocitrate dehydrogenase 1 (IDH1) status of the tumor. Data were collected in 137 consecutive patients who underwent awake craniotomy for removal of a brain tumor. The authors performed a retrospective analysis of the incidence of seizures based on the tumor location and its IDH1 mutation status, and then compared the groups for clinical variables and surgical outcome parameters. Tumor location was strongly associated with the occurrence of intraoperative seizures. Eleven patients (73%) with tumor located in the supplementary motor area (SMA) experienced intraoperative seizures, compared with 17 (13.9%) with tumors in the other three non-SMA brain regions (p awake craniotomy compared with patients who have a tumor in non-SMA frontal areas and other brain regions. The IDH1 mutation was more common in SMA region tumors compared with other brain regions, and may be an additional risk factor for the occurrence of intraoperative seizures.

  2. GREEN PACKAGING, GREEN PRODUCT, GREEN ADVERTISING, PERSEPSI, DAN MINAT BELI KONSUMEN

    OpenAIRE

    Imam Santoso; Rengganis Fitriani

    2016-01-01

    Environmental problems become one of the strategic issues in achieving global competitiveness. One of the issues is products that are made from environmental friendly materials or known as green product. Furthermore, in green products marketing, the company also uses green packaging and green advertising concept. This study aimed to analyze the effect of green packaging, green products, and green advertising on consumer perception and purchasing intention. The study was conducted in Ketawangg...

  3. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  4. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    Science.gov (United States)

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  5. Monomer adsorption of indocyanine green to gold nanoparticles

    NARCIS (Netherlands)

    Guerrini, Luca; Hartsuiker, Liesbeth; Manohar, Srirang; Otto, Cornelis

    2011-01-01

    NIR-dye encoded gold nanoparticles (GNP) are rapidly emerging as contrast agents in many bio-imaging/sensing applications. The coding process is usually carried out without control or a clear understanding of the metal–liquid interface properties which, in contrast, are critical in determining the

  6. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P; Jofre, M J [Nuclear Medicine Department, Military Hospital, Santiago (Chile); Iglesis, R; Schwartz, R; Gomez, L; Velez, R [Surgery Department, Military Hospital, Santiago (Chile); Sandoval, R [Pathology Department, Military Hospital, Santiago (Chile)

    2002-09-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 {+-} 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node.

  7. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Jofre, M.J.; Iglesis, R.; Schwartz, R.; Gomez, L.; Velez, R.; Sandoval, R.

    2002-01-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 ± 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node

  8. Intraoperative Cerebral Glioma Characterization with Contrast Enhanced Ultrasound

    Directory of Open Access Journals (Sweden)

    Francesco Prada

    2014-01-01

    Full Text Available Background. Contrast enhanced ultrasound (CEUS is a dynamic and continuous modality providing real-time view of vascularization and flow distribution patterns of different organs and tumors. Nevertheless its intraoperative use for brain tumors visualization has been performed few times, and a thorough characterization of cerebral glioma had never been performed before. Aim. To perform the first characterization of cerebral glioma using CEUS and to possibly achieve an intraoperative differentiation of different gliomas. Methods. We performed CEUS in an off-label setting in 69 patients undergoing surgery for cerebral glioma. An intraoperative qualitative analysis was performed comparing iCEUS with B-mode imaging. A postprocedural semiquantitative analysis was then performed for each case, according to EFSUMB criteria. Results were related to histopathology. Results. We observed different CE patterns: LGG show a mild, dotted CE with diffuse appearance and slower, delayed arterial and venous phase. HGG have a high CE with a more nodular, nonhomogeneous appearance and fast perfusion patterns. Conclusion. Our study characterizes for the first time human brain glioma with CEUS, providing further insight regarding these tumors’ biology. CEUS is a fast, safe, dynamic, real-time, and economic tool that might be helpful during surgery in differentiating malignant and benign gliomas and refining surgical strategy.

  9. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  10. An audit of intraoperative frozen section in Johor.

    Science.gov (United States)

    Khoo, J J

    2004-03-01

    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.

  11. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    Directory of Open Access Journals (Sweden)

    Terrence T. Kim

    2016-01-01

    Full Text Available We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy.

  12. Intraoperative confocal microscopy in the visualization of 5-aminolevulinic acid fluorescence in low-grade gliomas.

    Science.gov (United States)

    Sanai, Nader; Snyder, Laura A; Honea, Norissa J; Coons, Stephen W; Eschbacher, Jennifer M; Smith, Kris A; Spetzler, Robert F

    2011-10-01

    Greater extent of resection (EOR) for patients with low-grade glioma (LGG) corresponds with improved clinical outcome, yet remains a central challenge to the neurosurgical oncologist. Although 5-aminolevulinic acid (5-ALA)-induced tumor fluorescence is a strategy that can improve EOR in gliomas, only glioblastomas routinely fluoresce following 5-ALA administration. Intraoperative confocal microscopy adapts conventional confocal technology to a handheld probe that provides real-time fluorescent imaging at up to 1000× magnification. The authors report a combined approach in which intraoperative confocal microscopy is used to visualize 5-ALA tumor fluorescence in LGGs during the course of microsurgical resection. Following 5-ALA administration, patients with newly diagnosed LGG underwent microsurgical resection. Intraoperative confocal microscopy was conducted at the following points: 1) initial encounter with the tumor; 2) the midpoint of tumor resection; and 3) the presumed brain-tumor interface. Histopathological analysis of these sites correlated tumor infiltration with intraoperative cellular tumor fluorescence. Ten consecutive patients with WHO Grades I and II gliomas underwent microsurgical resection with 5-ALA and intraoperative confocal microscopy. Macroscopic tumor fluorescence was not evident in any patient. However, in each case, intraoperative confocal microscopy identified tumor fluorescence at a cellular level, a finding that corresponded to tumor infiltration on matched histological analyses. Intraoperative confocal microscopy can visualize cellular 5-ALA-induced tumor fluorescence within LGGs and at the brain-tumor interface. To assess the clinical value of 5-ALA for high-grade gliomas in conjunction with neuronavigation, and for LGGs in combination with intraoperative confocal microscopy and neuronavigation, a Phase IIIa randomized placebo-controlled trial (BALANCE) is underway at the authors' institution.

  13. Greens of the European Green Capitals

    Science.gov (United States)

    Cömertler, Seval

    2017-10-01

    Well established and maintained green areas have a key role on reaching the high quality of life and sustainability in urban environments. Therefore, green areas must be carefully accounted and evaluated in the urban planning affairs. In this context, the European Green Capitals, which attach a great importance to the green areas, have a great potential to act as a role model for both small and big cities in all around the world. These leading cities (chronologically, Stockholm, Hamburg, Vitoria-Gasteiz, Nantes, Copenhagen, Bristol, Ljubljana, Essen and Nijmegen) are inspiring for the other cities which seek to achieve more sustainable and environmentally friendly places through green areas. From this point of view, the aim of this paper was to investigate the green areas of the European Green Capitals. The paper covered whole European Green Capitals, and the application form of each Green Capital was used as a primary data source. Consequently, the paper put forwarded that the European Green Capitals have considerably large amount and high proportion of green areas. Further, these cities provide an excellent access to the public green areas. As a result of abundant provision and proper distribution, the almost all citizens in most of the Green Capitals live within a distance of 300 meters to a green area. For further researches, the paper suggested that these green capitals should be investigated in terms of their efforts, measures, goals and plans, policies and implications to administer, to protect, to enhance and to expand the green areas.

  14. Experimental diode laser-assisted microvascular anastomosis.

    Science.gov (United States)

    Reali, U M; Gelli, R; Giannotti, V; Gori, F; Pratesi, R; Pini, R

    1993-05-01

    An experimental study to evaluate a diode-laser approach to microvascular end-to-end anastomoses is reported. Studies were carried out on the femoral arteries and veins of Wistar rats, and effective welding of vessel tissue was obtained at low laser power, by enhancing laser absorption with indocyanine green (Cardio-green) solution. The histologic and surgical effects of this laser technique were examined and compared with those of conventional microvascular sutured anastomoses.

  15. Clinical toxicity of peripheral nerve to intraoperative radiotherapy in a canine model

    International Nuclear Information System (INIS)

    Johnstone, Peter A. S.; DeLuca, Anne Marie; Bacher, John D.; Hampshire, Victoria A.; Terrill, Richard E.; Anderson, William J.; Kinsella, Timothy J.; Sindelar, William F.

    1995-01-01

    Purpose: The clinical late effects of intraoperative radiotherapy (IORT) on peripheral nerve were investigated in a foxhound model. Methods and Materials: Between 1982 and 1987, 40 animals underwent laparotomy with intraoperative radiotherapy of doses from 0-75 Gy administered to the right lumbosacral plexus. Subsequently, all animals were monitored closely and sacrificed to assess clinical effects to peripheral nerve. This analysis reports final clinical results of all animals, with follow-up to 5 years. Results: All animals treated with ≥ 25 Gy developed ipsilateral neuropathy. An inverse relationship was noted between intraoperative radiotherapy dose and time to neuropathy, with an effective dose for 50% paralysis (ED 50 ) of 17.2 Gy. One of the animals treated with 15 Gy IORT developed paralysis, after a much longer latency than the other animals. Conclusions: Doses of 15 Gy delivered intraoperatively may be accompanied by peripheral neuropathy with long-term follow-up. This threshold is less than that reported with shorter follow-up. The value of ED 50 determined here is in keeping with data from other animal trials, and from clinical trials in humans

  16. Intraoperative Imaging Modalities and Compensation for Brain Shift in Tumor Resection Surgery

    Directory of Open Access Journals (Sweden)

    Siming Bayer

    2017-01-01

    Full Text Available Intraoperative brain shift during neurosurgical procedures is a well-known phenomenon caused by gravity, tissue manipulation, tumor size, loss of cerebrospinal fluid (CSF, and use of medication. For the use of image-guided systems, this phenomenon greatly affects the accuracy of the guidance. During the last several decades, researchers have investigated how to overcome this problem. The purpose of this paper is to present a review of publications concerning different aspects of intraoperative brain shift especially in a tumor resection surgery such as intraoperative imaging systems, quantification, measurement, modeling, and registration techniques. Clinical experience of using intraoperative imaging modalities, details about registration, and modeling methods in connection with brain shift in tumor resection surgery are the focuses of this review. In total, 126 papers regarding this topic are analyzed in a comprehensive summary and are categorized according to fourteen criteria. The result of the categorization is presented in an interactive web tool. The consequences from the categorization and trends in the future are discussed at the end of this work.

  17. Intraoperative digital radiography for diagnosis of non-palpable breast lesions; Digitale intraoperative Praeparateradiographie bei diagnostischen Exzisionen nicht palpabler Laesionen der Brust

    Energy Technology Data Exchange (ETDEWEB)

    Diekmann, F.; Grebe, S.; Hamm, B. [Humboldt-Univ., Berlin (Germany). Inst. fuer Radiologie; Bick, U. [Humboldt-Univ., Berlin (Germany). Inst. fuer Radiologie; Chicago Univ., IL (United States). Dept. of Radiology; Winzer, K.J. [Humboldt-Univ., Berlin (Germany). Klinik fuer Allgemein-, Viszeral-, Gefaess- und Thoraxchirurgie; Paepke, S. [Humboldt-Univ., Berlin (Germany). Abt. fuer Frauenheilkunde und Geburtshilfe

    2000-12-01

    Purpose: A procedure for performing intraoperative digital radiography of diagnostic breast specimens directly in the operating suite with teleradiologic assessment by a radiologist is presented. The efficiency of this procedure is compared with that of conventional magnification mammography performed in the radiology department. Material and Methods: Thirty-six specimen radiographs obtained by conventional magnification mammography were compared with 38 intraoperative digital magnification radiographs (DIMA Soft P42 prototype, Feinfocus Inc., Garbsen). The radiographs were assessed for lesion conspicuity and time savings for the surgeon, anesthesiologist, and radiologist. Results: The new procedure identified all 38 labeled pathological lesions, and the conventional technique likewise had a detection rate of 100% (36/36). The new technique resulted in considerable time savings for the surgeon and the radiologist. The duration of surgery was shorter and the time interval from removal of the specimen to reporting of the results was reduced from about 23 min to about 13 min. A single radiograph was sufficient for complete visualization of the specimen in all cases. Conclusion: Digital intraoperative specimen radiography considerably reduces the time of surgery depending on the local conditions and is highly accurate in locating a suspicious area within the tissue. (orig.) [German] Ziel: Es wird die Moeglichkeit vorgestellt, digitale intraoperative Praeparateradiographie bei diagnostischen Exzisionen direkt im OP-Trakt mit teleradiologischer Begutachtung durch den Radiologen durchzufuehren. Die Leistungsfaehigkeit des Verfahrens wurde mit der konventionellen Vergroesserungsmammographie im Roentgeninstitut verglichen. Material und Methode: Es wurden 36 Praeparateaufnahmen, die mit der herkoemmlichen konventionellen Vergroesserungsmammographie durchgefuehrt worden waren, mit 38 intraoperativen digitalen Vergroesserungsaufnahmen (DIMA Soft P42, Fa. Feinfocus, Garbsen

  18. Low-field magnetic resonance imaging for intraoperative use in neurosurgery: a 5-year experience

    International Nuclear Information System (INIS)

    Nimsky, Christopher; Ganslandt, Oliver; Buchfelder, Michael; Fahlbusch, Rudolf; Tomandl, Bernd

    2002-01-01

    The aim of this study was to evaluate the feasibility and point out the indications of intraoperative MR imaging in neurosurgical procedures. The MR imaging was performed using a 0.2-T scanner which was located in a radiofrequency-shielded operating theater. Three major setups for intraoperative imaging were possible: inside the scanner; at the 5-Gauss line; or in an adjacent operating theater. Additionally, in lesions adjacent to eloquent brain areas microscope- and pointer-based neuronavigation with integrated functional data was applied. Three hundred ten patients were investigated in the previous 5 years, among them gliomas (n=95), pituitary tumors (n=81), and 39 non-lesional cases in whom resective or disconnective epilepsy surgery was carried out. We did not observe any adverse effects due to intraoperative MR imaging. Image quality was sufficient to evaluate the extent of the tumor resection in the majority of cases. The main indications for intraoperative MR imaging were the evaluation of the extent of a resection in glioma, ventricular tumor, pituitary tumor, and in epilepsy surgery. Intraoperative MR imaging offers the possibility of further tumor removal during the same surgical procedure in case of tumor remnants, increasing the rate of complete tumor removal. Furthermore, the effects of brain shift, which would lead to inaccurate neuronavigation, can be compensated for by an update of the neuronavigation system with intraoperative MR image data. (orig.)

  19. The utility of intraoperative ultrasound in modified radical neck dissection: a pilot study.

    Science.gov (United States)

    Agcaoglu, Orhan; Aliyev, Shamil; Taskin, Halit Eren; Aksoy, Erol; Siperstein, Allan; Berber, Eren

    2014-04-01

    Although the value of surgeon-performed neck ultrasound (SPUS) for thyroid nodules has been validated, the utility of intraoperative ultrasound (US) in modified radical neck dissection (MRND) has not been reported in the literature. The aim of this study was to analyze the utility of intraoperative SPUS in assessing the completeness of MRND for thyroid cancer. Between 2007 and 2011, a total of 25 patients underwent MRND by 1 surgeon for thyroid cancer. All patients underwent intraoperative SPUS, which was repeated at the end of the neck dissection (completion US) to look for missed lymph nodes (LNs). There were 10 male and 15 female patients. Pathology included 23 papillary and 2 medullary carcinomas. The number of LNs removed per case was 23 ± 2, and the number of positive was LNs 5 ± 1. In 4 (16%) cases, intraoperative US detected 7 residual LNs, which would have been missed, if completion US were not done. These missed LNs were located in low-level IV (3 nodes), high-level II (2 nodes), and posterior level V (2 nodes) and measured 1.4 ± 0.2 cm. At follow-up, recurrence was seen in 2 (8%) patients, including a superior mediastinal recurrence in a patient with tall cell cancer and a jugular LN recurrence at level II in another patient with papillary thyroid cancer. This pilot study shows that intraoperative SPUS can help assess the completeness of MRND. According to our results, intraoperative completion US identifies LNs missed by palpation 16% of the time.

  20. Intraoperative Ultrasound in Patients Undergoing Transsphenoidal Surgery for Pituitary Adenoma: Systematic Review [corrected].

    Science.gov (United States)

    Marcus, Hani J; Vercauteren, Tom; Ourselin, Sebastien; Dorward, Neil L

    2017-10-01

    Transsphenoidal surgery is the gold standard for pituitary adenoma resection. However, despite advances in microsurgical and endoscopic techniques, some pituitary adenomas can be challenging to cure. We sought to determine whether, in patients undergoing transsphenoidal surgery for pituitary adenoma, intraoperative ultrasound is a safe and effective technologic adjunct. The PubMed database was searched between January 1996 and January 2016 to identify relevant publications that 1) featured patients undergoing transsphenoidal surgery for pituitary adenoma, 2) used intraoperative ultrasound, and 3) reported on safety or effectiveness. Reference lists were also checked, and expert opinions were sought to identify further publications. Ultimately, 10 studies were included, comprising 1 cohort study, 7 case series, and 2 case reports. One study reported their prototype probe malfunctioned, leading to false-positive results in 2 cases, and another study' prototype probe was too large to safely enter the sphenoid sinus in 2 cases. Otherwise, no safety issues directly related to use of intraoperative ultrasound were reported. In the only comparative study, remission occurred in 89.7% (61/68) of patients with Cushing disease in whom intraoperative ultrasound was used, compared with 83.8% (57/68) in whom it was not. All studies reported that surgeons anecdotally found intraoperative ultrasound helpful. Although there is limited and low-quality evidence available, the use of intraoperative ultrasound appears to be a safe and effective technologic adjunct to transsphenoidal surgery for pituitary adenoma. Advances in ultrasound technology may allow for more widespread use of such devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Intravenous dexmedetomidine infusion in adult patients undergoing open nephrolithotomy: Effects on intraoperative hemodynamics and blood loss; a random

    Directory of Open Access Journals (Sweden)

    Doaa A. Rashwan

    2015-10-01

    Conclusion: Dexmedetomidine infusion in patients undergoing open nephrolithotomy under general anesthesia was associated with intraoperative hemodynamic stability, which decreases intraoperative blood loss and the need for intraoperative blood transfusion.

  2. Markerless registration for image guided surgery. Preoperative image, intraoperative video image, and patient

    International Nuclear Information System (INIS)

    Kihara, Tomohiko; Tanaka, Yuko

    1998-01-01

    Real-time and volumetric acquisition of X-ray CT, MR, and SPECT is the latest trend of the medical imaging devices. A clinical challenge is to use these multi-modality volumetric information complementary on patient in the entire diagnostic and surgical processes. The intraoperative image and patient integration intents to establish a common reference frame by image in diagnostic and surgical processes. This provides a quantitative measure during surgery, for which we have been relied mostly on doctors' skills and experiences. The intraoperative image and patient integration involves various technologies, however, we think one of the most important elements is the development of markerless registration, which should be efficient and applicable to the preoperative multi-modality data sets, intraoperative image, and patient. We developed a registration system which integrates preoperative multi-modality images, intraoperative video image, and patient. It consists of a real-time registration of video camera for intraoperative use, a markerless surface sampling matching of patient and image, our previous works of markerless multi-modality image registration of X-ray CT, MR, and SPECT, and an image synthesis on video image. We think these techniques can be used in many applications which involve video camera like devices such as video camera, microscope, and image Intensifier. (author)

  3. From green architecture to architectural green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    that describes the architectural exclusivity of this particular architecture genre. The adjective green expresses architectural qualities differentiating green architecture from none-green architecture. Currently, adding trees and vegetation to the building’s facade is the main architectural characteristics...... they have overshadowed the architectural potential of green architecture. The paper questions how a green space should perform, look like and function. Two examples are chosen to demonstrate thorough integrations between green and space. The examples are public buildings categorized as pavilions. One......The paper investigates the topic of green architecture from an architectural point of view and not an energy point of view. The purpose of the paper is to establish a debate about the architectural language and spatial characteristics of green architecture. In this light, green becomes an adjective...

  4. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    Science.gov (United States)

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  5. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  6. Incidence of intraoperative hypothermia: adopting protocol for its prevention

    International Nuclear Information System (INIS)

    Al-Qahtani, Ali S.; Messahel, Farouk M.

    2003-01-01

    To determine the incidence of hypothermia during surgical procedures when adequate methods of preserving normothermia are applied .For this was a study in which patients ASA I-IV presented for surgery at the Armed Forces Hospital, Wadi Al- Dawasir, kingdom of Saudi Arabia ,during the period from July 2000 to February 2003 in whom body core temprature was between 35-37C ,were included. Ambient temperature of the operating room was thermostatically adjusted to record 26C and 24C if patents were < 10 year-old or above .Depending on type of surgery ;the patients were provided with space blankents and were lying on warm mattresses. Fluid or blood warmers and forced-air surface were used when needed for this. = Aggressive measures must be adopted to preserve normothermia as prevention of intraoperative hypothermia improves patients outcome .All patients shoud have their body temprature monitored during surgery .However application of available methods of keeping normothermia reduces the the incidence of intraoperative hypothermia but does not abolish it completely . Hypothermia patients should be closely moniterd during gradual rewarming preferably in the intensive care setting. A protocol for prevention of intraoperative hypothermia must be adopted by all operating theatres. (author)

  7. Intraoperative CT with integrated navigation system in spinal neurosurgery

    International Nuclear Information System (INIS)

    Zausinger, S.; Heigl, T.; Scheder, B.; Schnell, O.; Tonn, J.C.; Uhl, E.; Morhard, D.

    2007-01-01

    For spinal surgery navigational system images are usually acquired before surgery with patients positioned supine. The aim of this study was to evaluate prospectively navigated procedures in spinal surgery with data acquisition by intraoperative computed tomography (iCT). CT data of 38 patients [thoracolumbar instability (n = 24), C1/2 instability (n = 6), cervicothoracic stabilization (n = 7), disk herniation (n = 1)] were acquired after positioning the patient in prone position. A sliding gantry 24 detector row CT was used for image acquisition. Data were imported to the frameless infrared-based neuronavigation station. A postprocedural CT was obtained to assess the extent of decompression and the accuracy of instrumentation. Intraoperative registration revealed computed accuracy 2 mm in 9/158 screws (5.6%), allowing immediate correction in five screws without any damage to vessels or nerves. There were three transient complications with clinical improvement in all patients. Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization. The procedure is rapid and easy to perform and - by replacing pre- and postoperative imaging-is not associated with additional exposure to radiation. (orig.)

  8. [Associated vessel heteromorphosis in laparoscopic complete mesocolic excision and solutions to intraoperative hemorrhage].

    Science.gov (United States)

    Jiao, Yurong; He, Jinjie; Li, Jun; Xu, Dong; Ding, Kefeng

    2018-03-25

    Vessel identification and dissection are the key processes of laparoscopic complete mesocolic excision (CME). Vascular injury will lead to complications such as prolonged operative time, intraoperative hemorrhage and ischemia of anastomotic stoma. Superior mesenteric artery (SMA), superior mesenteric vein(SMV), gastrointestinal trunk, left colic artery(LCA), sigmoid artery and marginal vessels in the mesentery have been found with possibility of heteromorphosis, which requires better operative techniques. Surgeons should recognize those vessel heteromorphosis carefully during operations and adjust strategies to avoid intraoperative hemorrhage. Preoperative abdominal computed tomography angiography(CTA) with three-dimensional reconstruction can find vessel heteromorphosis within surgical area before operation. Adequate dissection of veins instead of violent separation will decrease intraoperative bleeding and be helpful for dealing with the potential hemorrhage. When intraoperative hemorrhage occurs, surgeons need to control the bleeding by simple compression or vascular clips depending on the different situations. When the bleeding can not be stopped by laparoscopic operation, surgeons should turn to open surgery without hesitation.

  9. The Dutch Linguistic Intraoperative Protocol: a valid linguistic approach to awake brain surgery.

    Science.gov (United States)

    De Witte, E; Satoer, D; Robert, E; Colle, H; Verheyen, S; Visch-Brink, E; Mariën, P

    2015-01-01

    Intraoperative direct electrical stimulation (DES) is increasingly used in patients operated on for tumours in eloquent areas. Although a positive impact of DES on postoperative linguistic outcome is generally advocated, information about the neurolinguistic methods applied in awake surgery is scarce. We developed for the first time a standardised Dutch linguistic test battery (measuring phonology, semantics, syntax) to reliably identify the critical language zones in detail. A normative study was carried out in a control group of 250 native Dutch-speaking healthy adults. In addition, the clinical application of the Dutch Linguistic Intraoperative Protocol (DuLIP) was demonstrated by means of anatomo-functional models and five case studies. A set of DuLIP tests was selected for each patient depending on the tumour location and degree of linguistic impairment. DuLIP is a valid test battery for pre-, intraoperative and postoperative language testing and facilitates intraoperative mapping of eloquent language regions that are variably located. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. The Influence of Proactive Green Innovation and Reactive Green Innovation on Green Product Development Performance: The Mediation Role of Green Creativity

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2016-09-01

    Full Text Available This study fills the research gap in the exploration of the relationships between both proactive and reactive green innovations and green product development performance, and examines the mediating effect of green creativity. Structural equation modeling (SEM is utilized to test the hypotheses. From the sample of 146 valid respondents, the results show that proactive green innovation positively affects green creativity and green product development performance, and green creativity positively affects green product development performance. In addition, our findings also indicate that the relationship between proactive green innovation and green product development performance is partially mediated by green creativity. Accordingly, green creativity plays a critical role for companies to achieve a great green product development performance. However, reactive green innovation does not significantly influence green creativity and green product development performance. Companies should develop proactive green innovation rather than reactive green innovation in order to enhance their green creativity and increase their product development performance.

  11. Intraoperative mechanical ventilation: state of the art.

    Science.gov (United States)

    Ball, Lorenzo; Costantino, Federico; Orefice, Giulia; Chandrapatham, Karthikka; Pelosi, Paolo

    2017-10-01

    Mechanical ventilation is a cornerstone of the intraoperative management of the surgical patient and is still mandatory in several surgical procedures. In the last decades, research focused on preventing postoperative pulmonary complications (PPCs), both improving risk stratification through the use of predictive scores and protecting the lung adopting so-called protective ventilation strategies. The aim of this review was to give an up-to-date overview of the currently suggested intraoperative ventilation strategies, along with their pathophysiologic rationale, with a focus on challenging conditions, such as obesity, one-lung ventilation and cardiopulmonary bypass. While anesthesia and mechanical ventilation are becoming increasingly safe practices, the contribution to surgical mortality attributable to postoperative lung injury is not negligible: for these reasons, the prevention of PPCs, including the use of protective mechanical ventilation is mandatory. Mechanical ventilation should be optimized providing an adequate respiratory support while minimizing unwanted negative effects. Due to the high number of surgical procedures performed daily, the impact on patients' health and healthcare costs can be relevant, even when new strategies result in an apparently small improvement of outcome. A protective intraoperative ventilation should include a low tidal volume of 6-8 mL/kg of predicted body weight, plateau pressures ideally below 16 cmH2O, the lowest possible driving pressure, moderate-low PEEP levels except in obese patients, laparoscopy and long surgical procedures that might benefit of a slightly higher PEEP. The work of the anesthesiologist should start with a careful preoperative visit to assess the risk, and a close postoperative monitoring.

  12. SEP Montage Variability Comparison during Intraoperative Neurophysiologic Monitoring.

    Science.gov (United States)

    Hanson, Christine; Lolis, Athena Maria; Beric, Aleksandar

    2016-01-01

    Intraoperative monitoring is performed to provide real-time assessment of the neural structures that can be at risk during spinal surgery. Somatosensory evoked potentials (SEPs) are the most commonly used modality for intraoperative monitoring. SEP stability can be affected by many factors during the surgery. This study is a prospective review of SEP recordings obtained during intraoperative monitoring of instrumented spinal surgeries that were performed for chronic underlying neurologic and neuromuscular conditions, such as scoliosis, myelopathy, and spinal stenosis. We analyzed multiple montages at the baseline, and then followed their development throughout the procedure. Our intention was to examine the stability of the SEP recordings throughout the surgical procedure on multiple montages of cortical SEP recordings, with the goal of identifying the appropriate combination of the least number of montages that gives the highest yield of monitorable surgeries. Our study shows that it is necessary to have multiple montages for SEP recordings, as it reduces the number of non-monitorable cases, improves IOM reliability, and therefore could reduce false positives warnings to the surgeons. Out of all the typical montages available for use, our study has shown that the recording montage Cz-C4/Cz-C3 (Cz-Cc) is the most reliable and stable throughout the procedure and should be the preferred montage followed throughout the surgery.

  13. Pengaruh Green Marketing Hotel Terhadap Green Consumer Behavior

    OpenAIRE

    Yo Fernandez, Eunike Christe; Tjoanda, Evelyn

    2017-01-01

    Penelitian ini dilakukan untuk mengetahui pengaruh dari green marketing hotel terhadap green consumer behavior. Green marketing memiliki 3 dimensi, yaitu green product, green price, dan green promotion. Penelitian ini melibatkan 272 responden masyarakat Surabaya dan menggunakan metode regresi linear berganda. Hasil penelitian menunjukkan bahwa green product dan green price berpengaruh secara positif dan signifikan sedangkan green promotion berpengaruh namun tidak signifikan terhadap green con...

  14. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint

    OpenAIRE

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct...

  15. Nanocolloidal albumin-IRDye 800CW: A near-infrared fluorescent tracer with optimal retention in the sentinel lymph node

    NARCIS (Netherlands)

    Heuveling, Derrek A.; Visser, Gerard W.M.; De Groot, Mattijs; De Boer, Johannes F.; Baclayon, Marian; Roos, Wouter H.; Wuite, Gijs J.L.; Leemans, C. René; De Bree, Remco; Van Dongen, Guus A.M.S.

    2012-01-01

    Purpose: At present, the only approved fluorescent tracer for clinical near-infrared fluorescence-guided sentinel node (SN) detection is indocyanine green (ICG), but the use of this tracer is limited due to its poor retention in the SN resulting in the detection of higher tier nodes. We describe the

  16. Nanocolloidal albumin-IRDye 800CW: a near-infrared fluorescent tracer with optimal retention in the sentinel lymph node

    NARCIS (Netherlands)

    Heuveling, D.A.; Visser, G.W.M.; de Groot, M.; de Boer, J.F.; Salumbides - Baclayon, M.; Roos, W.H.; Wuite, G.J.L.; Leemans, C.R.; de Bree, R.; van Dongen, G.A.M.S.

    2012-01-01

    Purpose: At present, the only approved fluorescent tracer for clinical near-infrared fluorescence-guided sentinel node (SN) detection is indocyanine green (ICG), but the use of this tracer is limited due to its poor retention in the SN resulting in the detection of higher tier nodes. We describe the

  17. Microscope Integrated Intraoperative Spectral Domain Optical Coherence Tomography for Cataract Surgery: Uses and Applications.

    Science.gov (United States)

    Das, Sudeep; Kummelil, Mathew Kurian; Kharbanda, Varun; Arora, Vishal; Nagappa, Somshekar; Shetty, Rohit; Shetty, Bhujang K

    2016-05-01

    To demonstrate the uses and applications of a microscope integrated intraoperative Optical Coherence Tomography in Micro Incision Cataract Surgery (MICS) and Femtosecond Laser Assisted Cataract Surgery (FLACS). Intraoperative real time imaging using the RESCAN™ 700 (Carl Zeiss Meditec, Oberkochen, Germany) was done for patients undergoing MICS as well as FLACS. The OCT videos were reviewed at each step of the procedure and the findings were noted and analyzed. Microscope Integrated Intraoperative Optical Coherence Tomography was found to be beneficial during all the critical steps of cataract surgery. We were able to qualitatively assess wound morphology in clear corneal incisions, in terms of subclinical Descemet's detachments, tears in the inner or outer wound lips, wound gaping at the end of surgery and in identifying the adequacy of stromal hydration, for both FLACS as well as MICS. It also enabled us to segregate true posterior polar cataracts from suspected cases intraoperatively. Deciding the adequate depth of trenching was made simpler with direct visualization. The final position of the intraocular lens in the capsular bag and the lack of bioadhesivity of hydrophobic acrylic lenses were also observed. Even though Microscope Integrated Intraoperative Optical Coherence Tomography is in its early stages for its application in cataract surgery, this initial assessment does show a very promising role for this technology in the future for cataract surgery both in intraoperative decision making as well as for training purposes.

  18. Mechanism of the beneficial effects of ATP-MgCl2 following trauma-hemorrhage and resuscitation: downregulation of inflammatory cytokine (TNF, IL-6) release.

    Science.gov (United States)

    Wang, P; Ba, Z F; Morrison, M H; Ayala, A; Dean, R E; Chaudry, I H

    1992-04-01

    Although ATP-MgCl2 improves hepatocellular function in a nonheparinized model of trauma-hemorrhage and crystalloid resuscitation, it remains unknown whether the beneficial effects of this agent are due to downregulation of the release of the inflammatory cytokines, tumor necrosis factor (TNF), and interleukin-6 (IL-6) under those conditions. To study this, rats underwent a 5-cm laparotomy (i.e., trauma induced) and were bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of maximum bleedout volume was returned in the form of Ringer's lactate (RL). The animals were then resuscitated with four times the volume of shed blood with RL over 60 min. ATP-MgCl2 (50 mumoles/kg body weight each) or an equivalent volume of normal saline was infused intravenously for 95 min. This infusion was started during the last 15 min of RL resuscitation. Plasma levels of TNF and IL-6 were measured at 1.5 hr after the completion of resuscitation by cytokine-dependent cellular assays. Hepatic blood flow was determined by in vivo indocyanine green clearance (corrected by hepatic extraction ratio for indocyanine green), radioactive microspheres, and [3H]-galactose clearance techniques. The results indicate that the levels of circulating TNF and IL-6 increased significantly in the hemorrhaged-resuscitated animals. ATP-MgCl2 treatment, however, markedly decreased the synthesis and/or release of these cytokines to levels similar to the sham group. The markedly decreased hepatic blood flow (as determined by three different methods) and hepatic extraction ratio for indocyanine green were also restored by ATP-MgCl2 treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. [Microsurgery assisted by intraoperative magnetic resonance imaging and neuronavigation for small lesions in deep brain].

    Science.gov (United States)

    Song, Zhi-jun; Chen, Xiao-lei; Xu, Bai-nan; Sun, Zheng-hui; Sun, Guo-chen; Zhao, Yan; Wang, Fei; Wang, Yu-bo; Zhou, Ding-biao

    2012-01-03

    To explore the practicability of resecting small lesions in deep brain by intraoperative magnetic resonance imaging (iMRI) and neuronavigator-assisted microsurgery and its clinical efficacies. A total of 42 cases with small lesions in deep brain underwent intraoperative MRI and neuronavigator-assisted microsurgery. The drifting of neuronavigation was corrected by images acquired from intraoperative MR rescanning. All lesions were successfully identified and 40 cases totally removed without mortality. Only 3 cases developed new neurological deficits post-operatively while 2 of them returned to normal neurological functions after a follow-up duration of 3 months to 2 years. The application of intraoperative MRI can effectively correct the drifting of neuronavigation and enhance the accuracy of microsurgical neuronavigation for small lesions in deep brain.

  20. Premedication with oral Dextromethorphan reduces intra-operative Morphine requirement

    Directory of Open Access Journals (Sweden)

    R Talakoub

    2005-09-01

    Full Text Available Background: Intra-operative pain has adverse effects on hemodynamic parameters. Due to complications of opioids for pain relief, using non-opioids medication is preferred. The purpose of this study was to investigate the effect of oral dextrometorphan premedication on intra-operative Morphine requirement. Methods: After approval of the Ethics committee and informed consent, 40 adult patients who stand in American Society of Anesthesiologists Physical Status I and II, under general anesthesia for elective laparatomy were selected and classified in two equal groups randomly. In group A, oral dextromethorphan (60mg was administered at 10 PM and 6 AM preoperatively. In group B, placebo (dextrose was administered. After induction of general anesthesia and before skin incision, intravenous morphine (0.01 mg/kg was administered. During surgery, when systolic blood pressure or heart rate was increased more than 20% of the preoperative baseline, 0.01 mg/kg morphine was administered. At the end of surgery, the totally prescribed morphine (mg/kg and maximal increase in systolic, diastolic, mean arterial blood pressure and heart rate relative to the baseline values were calculated and statistically compared with student’s t-test. Results: The mean dose of administered morphine during surgery was significantly less in group A than group B (P<0.0001. Also, Maximal increase in systolic, diastolic and mean arterial blood pressure was significantly less in group A (p<0.003, p<0.004, p<0.0001, respectively. There was no significant difference in maximal heart rate increase between two groups (p<0.114. Conclusion: Oral dextromethorphan premedication may decrease intra-operative morphine requirement and reduce maximal increase in systolic and mean arterial blood pressure during surgery. Key words: Dextromethorphan, Morphine, Intra-operative, Premedication Hemodynamic

  1. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  2. Green(ing) infrastructure

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2014-03-01

    Full Text Available the generation of electricity from renewable sources such as wind, water and solar. Grey infrastructure – In the context of storm water management, grey infrastructure can be thought of as the hard, engineered systems to capture and convey runoff..., pumps, and treatment plants.  Green infrastructure reduces energy demand by reducing the need to collect and transport storm water to a suitable discharge location. In addition, green infrastructure such as green roofs, street trees and increased...

  3. INTRAOPERATIVE MOTIVE FOR PERFORMING A LAPAROSCOPIC APPENDECTOMY ON A POSTOPERATIVE HISTOLOGICAL PROVEN NORMAL APPENDIX

    NARCIS (Netherlands)

    Slotboom, T.; Hamminga, J. T. H.; Hofker, H. S.; Heineman, E.; Haveman, J. W.

    2014-01-01

    Background: Diagnostic laparoscopy is the ultimate tool to evaluate the appendix. However, the intraoperative evaluation of the appendix is difficult, as the negative appendectomy rate remains 12%-18%. The aim of this study is to analyze the intraoperative motive for performing a laparoscopic

  4. Fusion of intraoperative force sensoring, surface reconstruction and biomechanical modeling

    Science.gov (United States)

    Röhl, S.; Bodenstedt, S.; Küderle, C.; Suwelack, S.; Kenngott, H.; Müller-Stich, B. P.; Dillmann, R.; Speidel, S.

    2012-02-01

    Minimally invasive surgery is medically complex and can heavily benefit from computer assistance. One way to help the surgeon is to integrate preoperative planning data into the surgical workflow. This information can be represented as a customized preoperative model of the surgical site. To use it intraoperatively, it has to be updated during the intervention due to the constantly changing environment. Hence, intraoperative sensor data has to be acquired and registered with the preoperative model. Haptic information which could complement the visual sensor data is still not established. In addition, biomechanical modeling of the surgical site can help in reflecting the changes which cannot be captured by intraoperative sensors. We present a setting where a force sensor is integrated into a laparoscopic instrument. In a test scenario using a silicone liver phantom, we register the measured forces with a reconstructed surface model from stereo endoscopic images and a finite element model. The endoscope, the instrument and the liver phantom are tracked with a Polaris optical tracking system. By fusing this information, we can transfer the deformation onto the finite element model. The purpose of this setting is to demonstrate the principles needed and the methods developed for intraoperative sensor data fusion. One emphasis lies on the calibration of the force sensor with the instrument and first experiments with soft tissue. We also present our solution and first results concerning the integration of the force sensor as well as accuracy to the fusion of force measurements, surface reconstruction and biomechanical modeling.

  5. What is the optimal management of an intra-operative air leak in a colorectal anastomosis?

    Science.gov (United States)

    Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R

    2018-02-01

    An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  6. Detection of rheumatoid arthritis in humans by fluorescence imaging

    Science.gov (United States)

    Ebert, Bernd; Dziekan, Thomas; Weissbach, Carmen; Mahler, Marianne; Schirner, Michael; Berliner, Birgitt; Bauer, Daniel; Voigt, Jan; Berliner, Michael; Bahner, Malte L.; Macdonald, Rainer

    2010-02-01

    The blood pool agent indo-cyanine green (ICG) has been investigated in a prospective clinical study for detection of rheumatoid arthritis using fluorescence imaging. Temporal behavior as well as spatial distribution of fluorescence intensity are suited to differentiate healthy and inflamed finger joints after i.v. injection of an ICG bolus.

  7. Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles.

    Science.gov (United States)

    de-Pablo-Gómez-de-Liaño, L; Fernández-Vigo, J I; Ventura-Abreu, N; Morales-Fernández, L; García-Feijóo, J; Gómez-de-Liaño, R

    2016-12-01

    To assess the agreement between intraoperative measurements of the limbus-insertion distance of the extraocular muscles with those measured by spectral domain optical coherence tomography. An analysis was made of a total of 67 muscles of 21 patients with strabismus. The limbus-insertion distance of the horizontal rectus muscles were measured using pre-operative SD-OCT and intra-operatively in 2 ways: 1) direct, after a conjunctival dissection in patients who underwent surgery, or 2) transconjunctival in patients who were treated with botulinum toxin, or in those who were not going to be operated. The intraclass correlation coefficient and Bland-Altman plots were calculated to determine the concordance between the 2 methods. The mean age was 45.9 ±20.9 years (range 16 to 85), with 52% being women. The percentage of identification by direct intraoperative measurement was 95.6% (22/23), by transconjunctival intraoperative measurement 90.9% (40/44), and by OCT 85% (57/67), with 22 muscles finally being analysed for the agreement study between direct intraoperative measurement and OCT measurements, and 35 muscles for the agreement between transconjuctival intraoperative measurement and OCT. The intraclass correlation coefficient showed good agreement with OCT and direct intraoperative measurements (0.931; 95% confidence interval (95% CI): 0.839-0.972; P<.001), and with transconjunctival intraoperative measurements (0.889; 95% CI: 0.790-0.942; P<.001). The SD-OCT is an effective technique to measure the distance from the insertion of the horizontal rectus muscles to the limbus, with a high agreement with intraoperative measurements being demonstrated. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  9. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  10. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    2006-01-01

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  11. Intraoperative MRI in pediatric brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choudhri, Asim F. [Le Bonheur Children' s Hospital, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Ophthalmology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Siddiqui, Adeel [University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Klimo, Paul; Boop, Frederick A. [University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Semmes-Murphey Neurologic and Spine Institute, Memphis, TN (United States); St. Jude Children' s Hospital, Division of Neurosurgery, Department of Surgery, Memphis, TN (United States)

    2015-09-15

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  12. Intraoperative MRI in pediatric brain tumors

    International Nuclear Information System (INIS)

    Choudhri, Asim F.; Siddiqui, Adeel; Klimo, Paul; Boop, Frederick A.

    2015-01-01

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  13. Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities

    Directory of Open Access Journals (Sweden)

    A. A. Skripnikov

    2015-01-01

    Full Text Available Purpose of the work was filing the electrophysiological phenomena observed in the process of intra-operative neuromonitoring followed by development of the results’ scale of intra-operative neuro-physiological testing of the pyramidal tract. Materials and мethods. The selection for evaluation included data of 147 protocols of intra-operative neuromonitoring in 135 patients (53 males, 82 females, aged from 1 y. 5 m. to 52 years (14,1±0,7 years with spinal deformities of different etiology who underwent instrumentation spinal correction followed by fixation of thoracic / thoracolumbar spine segments using various variants of internal systems of trans-pedicular fixation. Intra-operative neuro-monitoring was performed using system «ISIS IOM» (Inomed Medizintechnik GmbH, Germany. The changes of motor evoked potentials were evaluated according to this scale. Results. Five types of pyramidal system reaction to operative invasion were revealed. According to neurophysiological criteria three grades of the risk of neurological disorders development during operative spinal deformity correction and, correspondingly, three levels of anxiety for the surgeon were defined. Conclusion. Intra-operative neurophysiological monitoring is the effective highly technological instrument to prevent neurological disorders in the spinal deformity. Offered rating scale of the risk of neurological complications gives the possibility to highlight three levels of anxiety during operative invasion.

  14. Intraoperative translabial ultrasound for urethral diverticula: A road map for surgeons

    International Nuclear Information System (INIS)

    El-Zein, C.; Khoury, N.; El-Zein, Y.; Bulbul, M.; Birjawi, G.

    2009-01-01

    Purpose: To highlight the importance of intraoperative translabial ultrasound, for identification of diverticular neck allowing complete resection of periurethral diverticula and decrease in the recurrence rate. Material and methods: This study included 4 women of age range between 38 and 68 years presenting for recurrent urinary tract infections and urethral pain. All had translabial urethral ultrasound and cystoscopy with and without U/C guidance. Results: Prior cystoscopy in all these patients failed to demonstrate the diverticulum. Translabial ultrasound showed the diverticula some of which were infected. Ultrasound was used intraoperatively to guide the surgeon. With this approach the abnormality was confirmed and the neck of the diverticulum was identified through percutaneous needle insertion. This allowed complete resection of the diverticula. Conclusion: Translabial ultrasound is a non-invasive technique that plays a major role in examining the urethra and identifying the periuthral diverticula. In our experience, it was very useful as an adjunct to guide the surgeon intraoperatively allowing complete excision of the diverticulum.

  15. Intraoperative translabial ultrasound for urethral diverticula: A road map for surgeons

    Energy Technology Data Exchange (ETDEWEB)

    El-Zein, C.; Khoury, N.; El-Zein, Y. [Department of Diagnostic Radiology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon); Bulbul, M. [Department of Urology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon); Birjawi, G. [Department of Diagnostic Radiology, American University of Beirut Medical Center, Bliss Street, P.O. Box 11-0236, Riad El Solh 1107 2020, Beirut (Lebanon)], E-mail: gb02@aub.edu.lb

    2009-04-15

    Purpose: To highlight the importance of intraoperative translabial ultrasound, for identification of diverticular neck allowing complete resection of periurethral diverticula and decrease in the recurrence rate. Material and methods: This study included 4 women of age range between 38 and 68 years presenting for recurrent urinary tract infections and urethral pain. All had translabial urethral ultrasound and cystoscopy with and without U/C guidance. Results: Prior cystoscopy in all these patients failed to demonstrate the diverticulum. Translabial ultrasound showed the diverticula some of which were infected. Ultrasound was used intraoperatively to guide the surgeon. With this approach the abnormality was confirmed and the neck of the diverticulum was identified through percutaneous needle insertion. This allowed complete resection of the diverticula. Conclusion: Translabial ultrasound is a non-invasive technique that plays a major role in examining the urethra and identifying the periuthral diverticula. In our experience, it was very useful as an adjunct to guide the surgeon intraoperatively allowing complete excision of the diverticulum.

  16. Can we trust intraoperative culture results in nonunions?

    Science.gov (United States)

    Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W

    2014-07-01

    To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

  17. Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas.

    Science.gov (United States)

    Urman, Bulent; Boza, Aysen; Ata, Baris; Aksu, Sertan; Arslan, Tonguc; Taskiran, Cagatay

    2018-01-01

    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision. Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease.

  18. Single high dose intraoperative electrons for advanced stage pancreatic cancer: Phase I pilot study

    International Nuclear Information System (INIS)

    Goldson, A.L.; Ashaveri, E.; Espinoza, M.C.

    1981-01-01

    Phase I toxicity studies with intraoperative radiotherapy proved to be a feasible adjunct to surgery for unresectable malignancies of the pancreas at Howard University Hospital. There have been minimal side effects or complications related to the combination of limited surgical decompression and intraoperative radiotherapy alone. The toxic effects of intraoperative radiotherapy on normal tissues is being assessed on a dose volume basis. Doses of 2000 to 2500 rad in a single exposure to include the pancreas, regional nodes and duodenum are acceptable if the total treatment volume is less than or equal to 100 cm. The tumoricidal effects on the cancer are demonstratable when one reviews the pathological specimens that illustrate massive tumor necrosis and fibros replacement, but in all cases reviewed, viable cancer was noted. Intraoperative radiotherapy, therefore, represents a significant boost dose for resectable, partially resectable or non-resectable tumors when added to conventional external beam irradiation and/or chemotherapy. Preliminary clinical data and minimal toxicity justifies further investigation

  19. Early Experience with Combining Awake Craniotomy and Intraoperative Navigable Ultrasound for Resection of Eloquent Region Gliomas.

    Science.gov (United States)

    Moiyadi, Aliasgar; Shetty, Prakash

    2017-03-01

    Introduction  Optimal resection of tumors in eloquent locations requires a combination of intraoperative imaging and functional monitoring during surgery. Combining awake surgery with intraoperative magnetic resonanceis logistically challenging. Navigable ultrasound (US) is a useful alternative in such cases. Methods  A total of 22 subjects with eloquent tumors were operated on (1 intended biopsy and 21 intended radical resections) using combined modality three-dimensional (3D) US and awake craniotomy with intraoperative clinical monitoring. We describe the technical details for these cases specifically addressing the feasibility of combining the two modalities. Results  US was used for resection control in 18 cases. There were technical limitations in three cases. Transient intraoperative worsening was encountered in eight, necessitating premature termination of the procedure. All patients tolerated the awake procedure well. Mean duration of the surgery was 3.2 hours. Radical resections were obtained in 14 of 18 where this was intended and in 12 of the 13 where there was no adverse intraoperative monitoring event prompting premature termination of the resection. Conclusions  Combining awake surgery with 3DUS is feasible and beneficial. It does not entail any additional surgical workflow modification or patient discomfort. This combined modality intraoperative monitoring can be beneficial for eloquent region tumors. Georg Thieme Verlag KG Stuttgart · New York.

  20. Debate: Pro intraoperative radiation therapy in breast cancer; Debat: pour la radiotherapie peroperatoire dans le cancer du sein

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.B.; Lemanski, C.; Azria, D. [Departement de radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France); Gutowski, M.; Rouanet, P.; Saint-Aubert, B. [Departement de chirurgie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France)

    2011-10-15

    The use of intraoperative radiation therapy in breast cancer patients started about 20 years ago. Several retrospective and prospective studies have been published. Intraoperative radiation therapy was initially given as a boost to the tumour bed, followed by whole-breast irradiation. These studies have demonstrated the feasibility of the technique, with local control rates and cosmetic results similar to those obtained with standard treatments. Accelerated partial breast irradiation yields local recurrence rates as low as those observed after whole-breast irradiation. Intraoperative radiation therapy as a single irradiation modality with a unique dose has been investigated in recent prospective studies showing satisfactory local results. Intraoperative radiation therapy can be proposed either as a boost or as a unique treatment in selected cases (tumour size, nodal and hormonal status, patient's age). Intraoperative radiation therapy can be delivered by orthovoltage (50 kV) X-rays from mobile generators, or by electrons from linear accelerators, mobile or fixed, dedicated or not to intraoperative radiation therapy. (authors)

  1. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR PERITONEAL MESOTHELIOMA

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2017-01-01

    Full Text Available Abstract Results of application of a new technology of intraoperative photodynamic therapy (IOFDT in patients with peritoneal mesothelioma developed at P. Herzen Moscow Oncology Research Institute are presented. The study included 8 patients. 3 patients underwent surgery in various amount: 1 – limited peritonectomy in the volume of tumor foci resection and resection of a large omentum, 1 – limited peritonectomy in the volume of tumor foci resection and atypical resection of the right lobe of the liver, 1 – only resection of the large omentum due to the fact that the tumor was located only in a large omentum and no signs of lesions of the parietal peritoneum was revealed by intraoperative revision. Surgical intervention in these patients was concluded by IOPDT. The remaining 5 patients underwent only IOPDT. After the treatment, two patients underwent additional courses of laparoscopic IOPDT. Of the 8 patients enrolled in the study, 4 died from the underlying disease, 1 from cardiovascular disease with recurrence of the disease, 1 from cardiovascular disease without signs of recurrence, 2 were monitored for 6 months and 146 months (12 years. Thus, in the group of patients with peritoneal mesothelioma, the maximum observation period was 146.44 months, the median survival was 48.4 months, the total specific 1-year survival was 85.7±13.2%, the three-year survival was 68.5±18.6%, the 5-year survival was 45.7 ± 22.4 %. The average life expectancy after treatment of patients with repeated courses of laparoscopic IOPDT was 87 months, without repeated courses – 35.8 months. Thus, life expectancy was higher in patients with repeated courses of laparoscopic IOPDT. Small sample size caused to the rarity of this pathology does not allow for statistically significant conclusions. However, the results of the study indicate the prospects of multi-course intraoperative photodynamic therapy in patients with peritoneal mesothelioma.

  2. Do Routine Preoperative and Intraoperative Urine Cultures Benefit Pediatric Vesicoureteral Reflux Surgery?

    Directory of Open Access Journals (Sweden)

    Daniel R. Hettel

    2017-01-01

    Full Text Available Objective. To determine if routine preoperative and intraoperative urine cultures (UCx are necessary in pediatric vesicoureteral (VUR reflux surgery by identifying their association with each other, preoperative symptoms, and surgical outcomes. Materials and Methods. A retrospective review of patients undergoing ureteral reimplant(s for primary VUR at a tertiary academic medical center between years 2000 and 2014 was done. Preoperative UCx were defined as those within 30 days before surgery. A positive culture was defined as >50,000 colony forming units of a single organism. Results. A total of 185 patients were identified and 87/185 (47.0% met inclusion criteria. Of those, 39/87 (45% completed a preoperative UCx. Only 3/39 (8% preoperative cultures returned positive, and all of those patients were preoperatively symptomatic. No preoperatively asymptomatic patients had positive preoperative cultures. Intraoperative cultures were obtained in 21/87 (24.1% patients; all were negative. No associations were found between preoperative culture results and intraoperative cultures or between culture result and postoperative complications. Conclusions. In asymptomatic patients, no associations were found between the completion of a preoperative or intraoperative UCx and surgical outcomes, suggesting that not all patients may require preoperative screening. Children presenting with symptoms of urinary tract infection (UTI prior to ureteral reimplantation may benefit from preoperative UCx.

  3. Intraoperative HDR brachytherapy for rectal cancer using a flexible intraoperative template: standard plans versus individual planning

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Nuyttens, Joost J.; Hanssens, Patrick E.J.; Levendag, Peter C.

    2004-01-01

    HDR intraoperative brachytherapy (IOBT) is applied to locally advanced rectal tumors using a 5 mm thick flexible intraoperative template (FIT). To reduce the procedure time, treatment planning is performed using standard plans that neglect the curvature of the FIT. We have calculated the individual treatment plan, based on the real geometry of the FIT, and the dose at clips placed during surgery. A mean treatment dose of 9.55±0.21 Gy was found for the individual plan, compared to the prescribed 10 Gy (P<0.0001). The mean central dose was 10.03±0.10 Gy in the standard plan and 9.20±0.32 Gy in the individual plan (P<0.0001). The mean dose at the corners of the FIT was 10.3 Gy in the standard plan and ranged between 10.3 and 10.5 Gy in the individual plan. In 63% of the clips, the dose was larger than 15.0 Gy, which is equivalent to a gap between the FIT and the target smaller than 5 mm. In 18% of the clips, the dose was smaller than 13.0 Gy indicating that locally the gap was larger than 5 mm. Clinical practice will have to prove if these small dose deviations influence the clinical outcome

  4. Laparoscopy vs robotics in surgical management of endometrial cancer: comparison of intraoperative and postoperative complications.

    Science.gov (United States)

    Seror, Julien; Bats, Anne-Sophie; Huchon, Cyrille; Bensaïd, Chérazade; Douay-Hauser, Nathalie; Lécuru, Fabrice

    2014-01-01

    To compare the rates of intraoperative and postoperative complications of robotic surgery and laparoscopy in the surgical treatment of endometrial cancer. Unicentric retrospective study (Canadian Task Force classification II-2). Tertiary teaching hospital. The study was performed from January 2002 to December 2011 and included patients with endometrial cancer who underwent laparoscopic or robotically assisted laparoscopic surgical treatment. Data collected included preoperative data, tumor characteristics, intraoperative data (route of surgery, surgical procedures, and complications), and postoperative data (early and late complications according to the Clavien-Dindo classification, and length of hospital stay). Morbidity was compared between the 2 groups. The study included 146 patients, of whom 106 underwent laparoscopy and 40 underwent robotically assisted surgery. The 2 groups were comparable in terms of demographic and preoperative data. Intraoperative complications occurred in 9.4% of patients who underwent laparoscopy and in none who underwent robotically assisted surgery (p = .06). There was no difference between the 2 groups in terms of postoperative events. Robotically assisted surgery is not associated with a significant difference in intraoperative and postoperative complications, even when there were no intraoperative complications of robotically assisted surgery. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  5. Rapid intraoperative parathyroid hormone assay--more than just a comfort measure.

    LENUS (Irish Health Repository)

    Hanif, F

    2012-02-03

    BACKGROUND: Minimally invasive radio-guided parathyroidectomy (MIRP) has been embraced as an acceptable therapeutic approach to primary hyperparathyroidism. Preoperative sestamibi scanning has facilitated this technique. Here we evaluate the addition of a rapid intraoperative parathyroid hormone (iPTH) assay for patients undergoing MIRP. METHODS: A series of 51 patients underwent sestamibi localization of parathyroid glands followed by MIRP for primary hyperparathyroidism. Using peripheral venous samples, iPTH levels were measured prior to gland excision, as well as post-excision at 5, 10, and 15 minutes, taking a 50% reduction in iPTH level as indicative of complete excision. Next, changes in serum iPTH were compared with preoperative and postoperative changes in serum calcium, as well as levels of intraoperative ex-vivo radiation counts taken by hand-held gamma probe. RESULTS: In this series, a drop of greater than 50% in iPTH levels was observed in 94% of patients (n=48). Moreover, a significant drop in iPTH occurred within 10 minutes of excision in the majority (n=42) of cases (P<0.004). Changes in iPTH were comparable with the therapeutic reduction in calcium levels, as well as with the change in intraoperative ex-vivo gamma counts. CONCLUSIONS: This study demonstrates that the addition of an iPTH assay to MIRP provides a quick and reliable intraoperative diagnostic modality in confirming correct adenoma removal. Moreover, it precludes the requirement of frozen section.

  6. Customers’ Intention to Use Green Products: the Impact of Green Brand Dimensions and Green Perceived Value

    Directory of Open Access Journals (Sweden)

    Doszhanov Aibek

    2015-01-01

    Full Text Available This study aimed to identify the relationships between green brand dimension (green brand awareness, green brand image, and green brand trust, green perceived value and customer’s intention to use green products. Data was collected through structured survey questionnaire from 384 customers of three hypermarkets in Kuala-Lumpur. Data was analyzed based on multiple regression analysis. The results indicate that there are significant relationships between green brand awareness, green brand trust, green perceived value, and customer’s intention to use green products. However, green brand image was not found to have significant relationship with customer’s intention to use green products. The discussion presented suggestions for marketers and researchers interested in green branding.

  7. Intraoperative perception and sensation in laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Srivannaboon, Sabong; Chansue, Ekktet

    2004-04-01

    To investigate intraoperative perception and sensation during Laser in situ Keratomileusis (LASIK). Sixty patients with uneventful LASIK were included. All procedures were performed by one surgeon with one technique. Any patient with intra-operative complications was excluded. The patients were asked to fill in the subjective evaluation form regarding their perception and sensation during the operation. Twenty-nine patients (48%) reported no pain and twenty-six patients (43%) reported no burning sensation during the surgery. Nineteen patients (32%) reported no light perception during the suction period of microkeratome. There was no correlation between duration of the suction and no light perception (R2 0.01). Thirty-four patients (56%) reported no trouble in maintaining visual fixation at the red light during the laser treatment. Ten patients (16%) reported they could clearly see the movement during the surgery and 5 out of 10 patients (50% of 16%) reported visual frightening. Fifty cases (84%) reported no visual frightening during the surgery after reassurance of the visual experience by the surgeon before the surgery. Patients undergoing LASIK may experience different visual perceptions. Reassurance of the intraoperative perception and sensation before the surgery can reduce the visual frightening.

  8. Combined intraoperative and external irradiation of the celiac artery in the rabbit: Effects on gastric mucosal blood flow; Kombinierte intraoperative und externe Bestrahlung der Arteria coeliaca beim Kaninchen: Auswirkungen auf die Durchblutung der Magenschleimhaut

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, W. [Universitaetsklinikum Carl Gustav Carus, Dresden (Germany). Klinik und Poliklinik fuer Strahlentherapie]|[GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Kallfass, E. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Berg, D. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Kummermehr, J. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany)

    1996-12-01

    Aim: To demonstrate changes in gastric mucosal blood flow caused by intraoperative radiotherapy of the celiac artery combined with external radiotherapy of the upper abdomen in a rabbit model. The study was designed to identify a possible correlation between a radiation-induced reduction in mucosal blood flow and the induction of gastric ulcer. Material and Method: Intraoperative radiation doses of 0 or 30 Gy were given to the celiac artery in rabbits. After a delay of 14 days external radiotherapy of the upper abdomen with 3x4 Gy/week to a maximum total dose of 40 Gy was initiated. Gastric mucosal blood flow was assessed by intraventricular injection of radioactively-labelled microspheres (15 {mu}m) followed by measurement of radioactivity in the mucosa. The injections were performed at various time intervals between 2 and 63 days after intraoperative radiation. Results: Intraoperative radiotherapy, including sham-intraoperative radiation, resulted in a transitory reduction of mucosal blood flow by about 50% of the control value on day 7. After a temporary recovery by day 14, a marked and permanent reduction in blood flow was assessed after week 6. This time corresponds to the time of development of gastric ulcer. Conclusions: A relationship between the time of ulcer development and of reduced gastric mucosal blood flow was observed after combined intraoperative and external radiotherapy. The mechanical component of intraoperative treatment has to be emphasized. Reduced blood flow was also seen after intraoperative radiotherapy alone, without an induction of ulcer by this treatment. Hence additional mucosal damage by external radiation must be present for the induction of gastric ulcer. (orig.) [Deutsch] Ziel: Untersuchung der Veraenderungen der Magenschleimhautdurchblutung am Kaninchen als Folge einer kombinierten intraoperativen Bestrahlung der Arteria coeliaca und externen Bestrahlung des Oberbauchs. Durch diesen Ansatz sollte ein moeglicher Zusammenhang

  9. Is Intraoperative Diffusion tensor Imaging at 3.0T Comparable to Subcortical Corticospinal tract Mapping?

    Czech Academy of Sciences Publication Activity Database

    Ostrý, S.; Belšan, T.; Otáhal, Jakub; Beneš, V.; Netuka, D.

    2013-01-01

    Roč. 73, č. 5 (2013), s. 797-807 ISSN 0148-396X Institutional support: RVO:67985823 Keywords : corticospinal tract * intraoperative tractography * intraoperative image distortion * motor -evoked potentials * subcortical mapping Subject RIV: FH - Neurology Impact factor: 3.031, year: 2013

  10. Intraoperative ultrasound to facilitate removal of a submucosal foreign body.

    Science.gov (United States)

    Smith, Matthew E; Riffat, Faruque; Berman, Laurence H; Jani, Piyush

    2014-01-01

    A 61-year-old man with a history of fish bone ingestion and poorly localized symptoms was seen. His clinical examination was unremarkable, but CT demonstrated a foreign body deeply embedded within his tongue. Intraoperative ultrasound (US) guidance facilitated identification of a bone, allowing a needle to be placed as a guide to dissection. Repeat US scanning through the incision permitted precisely targeted surgery. CT and US are the most effective imaging techniques for localizing fish bones. Intraoperative US can be used to accurately locate a submucosal fish bone in mobile tissue such as the tongue, and focused, image-guided dissection can reduce surgical tissue trauma. © 2014 Wiley Periodicals, Inc.

  11. The Influence of Proactive Green Innovation and Reactive Green Innovation on Green Product Development Performance: The Mediation Role of Green Creativity

    OpenAIRE

    Yu-Shan Chen; Tai-Wei Chang; Chun-Yu Lin; Pi-Yu Lai; Kuan-Hung Wang

    2016-01-01

    This study fills the research gap in the exploration of the relationships between both proactive and reactive green innovations and green product development performance, and examines the mediating effect of green creativity. Structural equation modeling (SEM) is utilized to test the hypotheses. From the sample of 146 valid respondents, the results show that proactive green innovation positively affects green creativity and green product development performance, and green creativity positivel...

  12. Low-grade Glioma Surgery in Intraoperative Magnetic Resonance Imaging: Results of a Multicenter Retrospective Assessment of the German Study Group for Intraoperative Magnetic Resonance Imaging.

    Science.gov (United States)

    Coburger, Jan; Merkel, Andreas; Scherer, Moritz; Schwartz, Felix; Gessler, Florian; Roder, Constantin; Pala, Andrej; König, Ralph; Bullinger, Lars; Nagel, Gabriele; Jungk, Christine; Bisdas, Sotirios; Nabavi, Arya; Ganslandt, Oliver; Seifert, Volker; Tatagiba, Marcos; Senft, Christian; Mehdorn, Maximilian; Unterberg, Andreas W; Rössler, Karl; Wirtz, Christian Rainer

    2016-06-01

    The ideal treatment strategy for low-grade gliomas (LGGs) is a controversial topic. Additionally, only smaller single-center series dealing with the concept of intraoperative magnetic resonance imaging (iMRI) have been published. To investigate determinants for patient outcome and progression-free-survival (PFS) after iMRI-guided surgery for LGGs in a multicenter retrospective study initiated by the German Study Group for Intraoperative Magnetic Resonance Imaging. A retrospective consecutive assessment of patients treated for LGGs (World Health Organization grade II) with iMRI-guided resection at 6 neurosurgical centers was performed. Eloquent location, extent of resection, first-line adjuvant treatment, neurophysiological monitoring, awake brain surgery, intraoperative ultrasound, and field-strength of iMRI were analyzed, as well as progression-free survival (PFS), new permanent neurological deficits, and complications. Multivariate binary logistic and Cox regression models were calculated to evaluate determinants of PFS, gross total resection (GTR), and adjuvant treatment. A total of 288 patients met the inclusion criteria. On multivariate analysis, GTR significantly increased PFS (hazard ratio, 0.44; P surgery. Patients with accidentally left tumor remnants showed a similar prognosis compared with patients harboring only partially resectable tumors. Use of high-field iMRI was significantly associated with GTR. However, the field strength of iMRI did not affect PFS. EoR, extent of resectionFLAIR, fluid-attenuated inversion recoveryGTR, gross total resectionIDH1, isocitrate dehydrogenase 1iMRI, intraoperative magnetic resonance imagingLGG, low-grade gliomaMGMT, methylguanine-deoxyribonucleic acid methyltransferasenPND, new permanent neurological deficitOS, overall survivalPFS, progression-free survivalSTR, subtotal resectionWHO, World Health Organization.

  13. Tolerance of retroperitoneal structures to intraoperative radiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.; Terrill, R.

    1982-01-01

    In conjunction with the clinical development of intraoperative radiotherapy, a study was undertaken in dogs to define the tolerance of normal anatomic structures in the retroperitoneum to radiation delivered during operation. Twenty adult dogs were subjected to laparotomy and intraoperative 11 MeV electron irradiation in single doses ranging from 0.to 5000 rad. Animals were followed regularly with clinical observation, blood count, serum chemistries, pyelography, and angiography. Animals were sacrificed and autopsied at regular intervals up to 12 months following treatment to assess radiation-induced complications or tissue damage. Irradiation field in all dogs consisted of a 4 X 15 cm rectangle extending in the retroperitoneum from the level of the renal vessels to the bifurcation of aorta and vena cava. The field included aorta, vena cava, inferior portion of left kidney, and distal portion of left ureter. No complications or histologic changes occurred in any animal given doses of 2000 rad, with a follow-up in excess of 18 months. A dose of 3000 rad was well tolerated, except for left ureteral occlusion in one animal. Mild vascular fibrosis was present inthe aorta and vena cava, and significant ureteral fibrosis developed by six months after doses of 4000 or 5000 rad. All animals that received 5000 rad died of radiation-related complications, including ureteral obstruction and rectal perforation. It was concluded that major vessels tolerate intraoperative irradiation well up to and including 3000 rad and that no clinically significant vascular problems develop after 4000 and 5000 rad, although some fibrosis does occur. The ureter and kidney appear to be the most radiosensitive structures inthe retroperitoneum, showing progressive changes at 300 rad or greater and showing the potential for serious complications after doses of 4000 rad or more

  14. Intra-operative parathyroid hormone measurements – experience of ...

    African Journals Online (AJOL)

    Background. Surgery is the treatment of choice for symptomatic primary hyperparathyroidism. The majority of research concerning intra-operative parathyroid hormone (ioPTH) measurements is conducted in university hospitals. Whether ioPTH measurements are feasible and useful in predicting the presence of remaining ...

  15. Development of a new compact intraoperative magnetic resonance imaging system: concept and initial experience.

    Science.gov (United States)

    Morita, Akio; Sameshima, Tetsuro; Sora, Shigeo; Kimura, Toshikazu; Nishimura, Kengo; Itoh, Hirotaka; Shibahashi, Keita; Shono, Naoyuki; Machida, Toru; Hara, Naoko; Mikami, Nozomi; Harihara, Yasushi; Kawate, Ryoichi; Ochiai, Chikayuki; Wang, Weimin; Oguro, Toshiki

    2014-06-01

    Magnetic resonance imaging (MRI) during surgery has been shown to improve surgical outcomes, but the current intraoperative MRI systems are too large to install in standard operating suites. Although 1 compact system is available, its imaging quality is not ideal. We developed a new compact intraoperative MRI system and evaluated its use for safety and efficacy. This new system has a magnetic gantry: a permanent magnet of 0.23 T and an interpolar distance of 32 cm. The gantry system weighs 2.8 tons and the 5-G line is within the circle of 2.6 m. We created a new field-of-view head coil and a canopy-style radiofrequency shield for this system. A clinical trial was initiated, and the system has been used in 44 patients. This system is significantly smaller than previous intraoperative MRI systems. High-quality T2 images could discriminate tumor from normal brain tissue and identify anatomic landmarks for accurate surgery. The average imaging time was 45.5 minutes, and no clinical complications or MRI system failures occurred. Floating organisms or particles were minimal (1/200 L maximum). This intraoperative, compact, low-magnetic-field MRI system can be installed in standard operating suites to provide relatively high-quality images without sacrificing safety. We believe that such a system facilitates the introduction of the intraoperative MRI.

  16. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  17. Diagnostic power and pitfalls of intraoperative consultation (frozen section) in rhabdomyosarcoma.

    Science.gov (United States)

    Kurtulan, Olcay; Kösemehmetoğlu, Kemal

    2015-01-01

    Intraoperative consultation plays an important role in the management of soft tissue sarcomas, such as rhabdomyosarcoma. In this study, we aimed to draw attention to the important points during frozen section interpretation, and analyse the accuracy of frozen diagnosis in rhabdomyosarcoma patients. The cases, both diagnosed as rhabdomyosarcoma or followed with a history of rhabdomyosarcoma, and interpreted with intraoperative consultation (frozen section) between 2000 and 2013 were culled from pathology archives. The diagnoses were confirmed by desmin and myogenin, immunohistochemically. The frozen and final diagnoses were noted of 21 biopsy specimens of 19 patients. Sensitivity and specificity of intraoperative consultation were calculated regarding to the major diagnostic discrepancies leading to a change in surgical management of the patient, after exclusion of the cases deferred to paraffin section. Of the evaluated 21 biopsy material, 3 (14%) were misdiagnosed: Of the 2 false negative embryonal rhabdomyosarcoma cases, sample was not representative of the tumor, and there was chemo/radiotherapy induced changes in the other case. In the only false positively diagnosed case with a known history of rhabdomyosarcoma, inflammatory cells were misinterpreted as small round cell neoplasm. In 5 (29%) of 21 biopsies, a frozen diagnosis could not be given, and the diagnosis was deferred. Six cases (29%) were evaluated with cytological squash or imprint preparation; none of the misdiagnosed cases was evaluated with adjunct cytological preparation. Six of 8 misdiagnosed or deferred biopsies showed morphological changes secondary to radiotherapy and/or chemotherapy. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated as 85%, 67%, 92% and 50%, respectively. Intraoperative consultation for rhabdomyosarcoma is a reliable tool with high sensitivity and fair specificity. Cases with treatment effect may lead to diagnostic difficulties

  18. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  19. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  20. Intraoperative radiotherapy in combined treatment of sinonasal malignant tumors

    Science.gov (United States)

    Novikov, V. A.; Gribova, O. V.; Vasiljev, R. V.; Choynzonov, E. L.; Shtin, V. I.; Shiianova, A. A.; Surkova, P. V.; Starceva, Zh. A.; Shilova, O. G.

    2017-09-01

    Obvious advantage of IORT (intraoperative radiotherapy) is that the radiation source is delivered directly to the bed of the tumor during surgery, thus avoiding the negative impact on the skin, subcutaneous tissue and reducing the risk of fibrosis. Sinonasal tumors—a convenient object for intraoperative radiotherapy application (surface location, relatively small size tumors, good operational access). The surface location and comparatively small size of neoplasms, good operational access provide an efficient and accurate transfer of the electron beam to the postoperative cavity to increase the irradiation dose in the areas of the most probable recurrence, which makes the tumors of this localization a convenient object for the use of the intraoperative radiation therapy. The treatment was conducted using a mobile compact betatron (MIB-6E), 10-12 Gy single dose. IORT session extends surgery period by 30 min. There were no pathological clinical and laboratory reactions on IORT in the early postoperative period. Carrying out the procedure is possible in various standard operating rooms. It does not require special security measures for the patients and the staff. IORT with the help of electron beam allows avoiding post-radiation reactions and achieving a 5-year—disease-free survival of 66% of the patients. IORT session is possible through a minimal incision during organ preservation surgeries. Evident economic feasibility provides the prospects of applying IORT in the clinical practice.

  1. Intraoperative panoramic image using alignment grid, is it accurate?

    Science.gov (United States)

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  2. Metaphysical green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    to adapt to urban environment. It explores the potential of Sensation of Green in the city. The paper questions whether the Sensation of Green could introduce a new spectrum of greens, beside the real green. It develops the term of metaphysical green – does green have to be green or can it be only...

  3. Limitations of intraoperative adrenal remnant volume measurement in patients undergoing subtotal adrenalectomy.

    Science.gov (United States)

    Brauckhoff, Michael; Stock, Karsten; Stock, Susanne; Lorenz, Kerstin; Sekulla, Carsten; Brauckhoff, Katrin; Thanh, Phuong Nguyen; Gimm, Oliver; Spielmann, Rolf Peter; Dralle, Henning

    2008-05-01

    Recent studies have shown that a minimum of approximately one-third of one normal adrenal gland is required for sufficient adrenocortical stress capacity. Correlation between intraoperative measurement, determination of remnant size by computed tomography (CT), and adrenocortical stress capacity has not been examined so far. Twenty-two patients with familial pheochromocytoma (n=13), sporadic pheochromocytoma (n=3), and adrenocortical tumors (n=6) who underwent unilateral or bilateral subtotal adrenalectomy (STAE, 28 adrenal remnants) were prospectively studied. Patients were examined in a multi-slice CT to determine residual adrenal tissue and by ACTH test 4 days and 3 months postoperatively. There was a slight significant correlation between intraoperative and CT calculated volumes (r=0.77; pSTAE has limitations. CT gives larger volumes compared with intraoperative determination. For calculation of a volume-function correlation of residual adrenal tissue, in clinical practice, the determination of relative adrenal residual volume is acceptable.

  4. The effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism.

    Science.gov (United States)

    Yilmaz, Yeliz; Kamer, Kemal Erdinc; Ureyen, Orhan; Sari, Erdem; Acar, Turan; Karahalli, Onder

    2016-08-01

    To investigate the effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism. This controlled, randomized, prospective cohort was carried out on 40 patients who admitted for surgery due to hyperthyroidism. Cases were randomly assigned to receive either preoperative treatment with Lugol solution (Group 1) or no preoperative treatment with Lugol solution (Group 2). Group 3 (n = 10) consisted of healthy adults with no known history and signs of hyperthyroidism. Blood flow through the thyroid arteries of patients was measured by color flow Doppler ultrasonography. Free T3, free T4, TSH, thyroid volume and the resistance index of the four main thyroid arteries were measured in all patients. There was not a significant difference between gender, preoperative serum thyroid hormone levels, or thyroid gland volumes between groups 1 and 2. The mean blood flow of the patients in Group 1 was significantly lower than values in Group 2. When age, gender, thyroid hormone, TSH, thyroid volume, blood flow, and Lugol solution treatment were included as independent variables, Lugol solution treatment (OR, 7.40; 95% CI, 1.02-58.46; p = 0.001) was found to be the only significant independent determinant of intraoperative blood loss. Lugol solution treatment resulted in a 7.40-fold decrease in the rate of intraoperative blood loss. Preoperative Lugol solution treatment was found to be a significant independent determinant of intraoperative blood loss. Moreover, preoperative Lugol solution treatment decreased the rate of blood flow, and intraoperative blood loss during thyroidectomy.

  5. Support surfaces for intraoperative prevention of pressure ulcers in patients undergoing surgery: a cost-effectiveness analysis.

    Science.gov (United States)

    Pham, Ba'; Teague, Laura; Mahoney, James; Goodman, Laurie; Paulden, Mike; Poss, Jeff; Li, Jianli; Sikich, Nancy Joan; Lourenco, Rosemarie; Ieraci, Luciano; Carcone, Steven; Krahn, Murray

    2011-07-01

    Patients who undergo prolonged surgical procedures are at risk of developing pressure ulcers. Recent systematic reviews suggest that pressure redistribution overlays on operating tables significantly decrease the associated risk. Little is known about the cost effectiveness of using these overlays in a prevention program for surgical patients. Using a Markov cohort model, we evaluated the cost effectiveness of an intraoperative prevention strategy with operating table overlays made of dry, viscoelastic polymer from the perspective of a health care payer over a 1-year period. We simulated patients undergoing scheduled surgical procedures lasting ≥90 min in the supine or lithotomy position. Compared with the current practice of using standard mattresses on operating tables, the intraoperative prevention strategy decreased the estimated intraoperative incidence of pressure ulcers by 0.51%, corresponding to a number-needed-to-treat of 196 patients. The average cost of using the operating table overlay was $1.66 per patient. Compared with current practice, this intraoperative prevention strategy would increase slightly the quality-adjusted life days of patients and by decreasing the incidence of pressure ulcers, this strategy would decrease both hospital and home care costs for treating fewer pressure ulcers originated intraoperatively. The cost savings was $46 per patient, which ranged from $13 to $116 by different surgical populations. Intraoperative prevention was 99% likely to be more cost effective than the current practice. In patients who undergo scheduled surgical procedures lasting ≥90 min, this intraoperative prevention strategy could improve patients' health and save hospital costs. The clinical and economic evidence support the implementation of this prevention strategy in settings where it has yet to become current practice. Copyright © 2011 Mosby, Inc. All rights reserved.

  6. Intraoperative irradiation in advanced cervical cancer

    International Nuclear Information System (INIS)

    Delgado, G.; Goldson, A.L.; Ashayeri, E.; Petrilli, E.S.

    1987-01-01

    Conventional treatment of cervical cancer, such as radical hysterectomy with lymphadenectomy or pelvic exenteration, is limited to the pelvis. Standard radio-therapeutic treatment is a combination of external-beam radiotherapy to the pelvis and intracavitary applications. However, there is a group of patients for whom external radiotherapy alone has limitations. This group consists primarily of patients with large pelvic lymph nodes containing metastatic cancer, metastatically involved paraaortic lymph nodes outside the usual pelvic radiation field, or large central tumors with parametrial involvement. In patients with cancer of the cervix, the incidence of metastasis to paraaortic lymph nodes is high. Attempts to treat paraaortic nodes with external radiotherapy have resulted in high complication rates because the treatment field includes the highly sensitive gastrointestinal tract. External radiation therapy after retroperitoneal exploration of lymph nodes does not seem to improve survival. In an attempt to circumvent the morbidity and mortality associated with conventional external-beam irradiation, the authors initiated a pilot study of intraoperative electron-beam irradiation of the paraaortic nodes and of the large metastatic lymph nodes in the pelvis. The intraoperative boost was followed by conventional fractionated external-beam irradiation. The theoretical advantages of this procedure include a higher radiation tumor dose without a concomitant increase in treatment morbidity and mortality

  7. Impact of intra-operative intraperitoneal chemotherapy on organ/space surgical site infection in patients with gastric cancer.

    Science.gov (United States)

    Liu, X; Duan, X; Xu, J; Jin, Q; Chen, F; Wang, P; Yang, Y; Tang, X

    2015-11-01

    Various risk factors for surgical site infection (SSI) have been identified such as age, overweight, duration of surgery, blood loss, etc. Intraperitoneal chemotherapy during surgery is a common procedure in patients with gastric cancer, yet its impact on SSI has not been evaluated. To evaluate whether intra-operative intraperitoneal chemotherapy is a key risk factor for organ/space SSI in patients with gastric cancer. All patients with gastric cancer who underwent surgery at the Department of Gastrointestinal Surgery between January 2008 and December 2013 were studied. The organ/space SSI rates were compared between patients who received intra-operative intraperitoneal chemotherapy and patients who did not receive intra-operative intraperitoneal chemotherapy, and the risk factors for organ/space SSI were analysed by univariate and multi-variate regression analyses. The microbial causes of organ/space SSI were also identified. Of the eligible 845 patients, 356 received intra-operative intraperitoneal chemotherapy, and the organ/space SSI rate was higher in these patients compared with patients who did not receive intra-operative intraperitoneal chemotherapy (9.01% vs 3.88%; P = 0.002). Univariate analysis confirmed the significance of this finding (odds ratio 2.443; P = 0.003). As a result, hospital stay was increased in patients who received intra-operative intraperitoneal chemotherapy {mean 20.91 days [95% confidence interval (CI) 19.76-22.06] vs 29.72 days (95% CI 25.46-33.99); P = 0.000}. The results also suggested that intra-operative intraperitoneal chemotherapy may be associated with more Gram-negative bacterial infections. Intra-operative intraperitoneal chemotherapy is a significant risk factor for organ/space SSI in patients with gastric cancer. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Clinical implementation of intraoperative cone-beam CT in head and neck surgery

    Science.gov (United States)

    Daly, M. J.; Chan, H.; Nithiananthan, S.; Qiu, J.; Barker, E.; Bachar, G.; Dixon, B. J.; Irish, J. C.; Siewerdsen, J. H.

    2011-03-01

    A prototype mobile C-arm for cone-beam CT (CBCT) has been translated to a prospective clinical trial in head and neck surgery. The flat-panel CBCT C-arm was developed in collaboration with Siemens Healthcare, and demonstrates both sub-mm spatial resolution and soft-tissue visibility at low radiation dose (e.g., software based on the open-source Image-Guided Surgery Toolkit (IGSTK). The CBCT C-arm has been successfully deployed in 15 head and neck cases and streamlined into the surgical environment using human factors engineering methods and expert feedback from surgeons, nurses, and anesthetists. Intraoperative imaging is implemented in a manner that maintains operating field sterility, reduces image artifacts (e.g., carbon fiber OR table) and minimizes radiation exposure. Image reviews conducted with surgical staff indicate bony detail and soft-tissue visualization sufficient for intraoperative guidance, with additional artifact management (e.g., metal, scatter) promising further improvements. Clinical trial deployment suggests a role for intraoperative CBCT in guiding complex head and neck surgical tasks, including planning mandible and maxilla resection margins, guiding subcranial and endonasal approaches to skull base tumours, and verifying maxillofacial reconstruction alignment. Ongoing translational research into complimentary image-guidance subsystems include novel methods for real-time tool tracking, fusion of endoscopic video and CBCT, and deformable registration of preoperative volumes and planning contours with intraoperative CBCT.

  9. Administration of progesterone after trauma and hemorrhagic shock prevents hepatocellular injury.

    Science.gov (United States)

    Kuebler, Joachim F; Yokoyama, Yukihiro; Jarrar, Doraid; Toth, Balazs; Rue, Loring W; Bland, Kirby I; Wang, Ping; Chaudry, Irshad H

    2003-07-01

    Administration of a single dose of progesterone following trauma and hemorrhage in progesterone-deficient rats would ameliorate the inflammatory response and hepatocellular damage. A university laboratory. Ovariectomized female Sprague-Dawley rats (250-350 g; Charles River Laboratories, Wilmington, Mass) underwent a 5-cm midline laparotomy (ie, induction of soft tissue trauma), were bled to a mean arterial blood pressure of 35 mm Hg for about 90 minutes, and then were resuscitated using Ringer lactate solution. Progesterone (25 mg/kg of body weight) or vehicle was administered subcutaneously at the end of resuscitation. In additional animals, Kupffer cells were isolated following trauma, hemorrhage, and resuscitation and treated in vitro with progesterone, lipopolysaccharide, or both. Six hours following resuscitation, plasma tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) levels and liver myeloperoxidase activity were determined. Hepatocellular function (maximum velocity of indocyanine green clearance [Vmax] and the efficiency of the active transport or Michaelis-Menten constant [Km]) and plasma levels of transaminases were measured 20 hours after resuscitation. Kupffer cell IL-6 and TNF-alpha production were assessed. Plasma levels of TNF-alpha, IL-6, aspartate aminotransferase, and alanine aminotransferase, as well as hepatic myeloperoxidase activity were increased, whereas indocyanine green clearance was depressed in vehicle-treated rats following trauma-hemorrhage. Animals treated with progesterone showed significantly reduced levels of the TNF-alpha, IL-6, and transaminases as well as reduced myeloperoxidase activity in the liver. Progesterone-treated animals showed increased Vmax and Kmax values for indocyanine green. In vitro treatment of Kupffer cells with progesterone decreased TNF-alpha production but did not affect the production of IL-6. Progesterone administration following trauma-hemorrhage ameliorates the proinflammatory response

  10. Liver haemodynamics and function in alcoholic cirrhosis. Relation to testosterone treatment and ethanol consumption

    DEFF Research Database (Denmark)

    Gluud, C; Henriksen, J H

    1987-01-01

    group, a significant change in median values of portal pressure (-23%, n = 34, P less than 0.005), hepatic blood flow (-22%, n = 28, P less than 0.001), indocyanine green clearance (+16%, n = 29, P less than 0.01), and galactose elimination capacity (+8%, n = 31, P less than 0.05) was observed. However...

  11. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  12. Clinical application of photodynamic medicine technology using light-emitting fluorescence imaging based on a specialized luminous source.

    Science.gov (United States)

    Namikawa, Tsutomu; Fujisawa, Kazune; Munekage, Eri; Iwabu, Jun; Uemura, Sunao; Tsujii, Shigehiro; Maeda, Hiromichi; Kitagawa, Hiroyuki; Fukuhara, Hideo; Inoue, Keiji; Sato, Takayuki; Kobayashi, Michiya; Hanazaki, Kazuhiro

    2018-04-04

    The natural amino acid 5-aminolevulinic acid (ALA) is a protoporphyrin IX (PpIX) precursor and a new-generation photosensitive substance that accumulates specifically in cancer cells. When indocyanine green (ICG) is irradiated with near-infrared (NIR) light, it shifts to a higher energy state and emits infrared light with a longer wavelength than the irradiated NIR light. Photodynamic diagnosis (PDD) using ALA and ICG-based NIR fluorescence imaging has emerged as a new diagnostic technique. Specifically, in laparoscopic examinations for serosa-invading advanced gastric cancer, peritoneal metastases could be detected by ALA-PDD, but not by conventional visible-light imaging. The HyperEye Medical System (HEMS) can visualize ICG fluorescence as color images simultaneously projected with visible light in real time. This ICG fluorescence method is widely applicable, including for intraoperative identification of sentinel lymph nodes, visualization of blood vessels in organ resection, and blood flow evaluation during surgery. Fluorescence navigation by ALA-PDD and NIR using ICG imaging provides good visualization and detection of the target lesions that is not possible with the naked eye. We propose that this technique should be used in fundamental research on the relationship among cellular dynamics, metabolic enzymes, and tumor tissues, and to evaluate clinical efficacy and safety in multicenter cooperative clinical trials.

  13. Internal Limiting Membrane Peeling to Prevent Post-vitrectomy Epiretinal Membrane Development in Retinal Detachment.

    Science.gov (United States)

    Akiyama, Kunihiko; Fujinami, Kaoru; Watanabe, Ken; Tsunoda, Kazushige; Noda, Toru

    2016-11-01

    To determine the efficacy of internal limiting membrane (ILM) peeling during vitrectomy for rhegmatogenous retinal detachment (RRD) regarding post-vitrectomy epiretinal membrane (ERM) development and visual outcomes. Retrospective, interventional, comparative case series. Setting: Institutional. One hundred and two consecutive eyes with RRD treated with vitrectomy and followed for at least 6 months. ILM was peeled without using dye such as indocyanine green (ICG). Observational Procedures: Patients were divided into 2 groups based on postoperative ERM development: Group 1, 81 eyes without ERM formation; Group 2, 21 eyes with ERM development. Patients also were divided into 2 subgroups: those with and without ILM peeling (58 and 44 eyes, respectively). Statistical analyses were performed between the 2 groups with/without ERM formation and between the 2 subgroups with/without ILM peeling for 5 preoperative factors including foveal involvement of the RRD, 4 intraoperative factors including ILM peeling, baseline best-corrected visual acuity (BCVA), and final BCVA. An association of ILM peeling with ERM prevention and the influence of ILM peeling on visual outcomes. ILM peeling was significantly (P peeling. ILM peeling without ICG staining during the initial vitrectomy for RRDs may prevent postoperative ERM formation with favorable visual outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Corantes vitais em cromovitrectomia Vital dyes in chromovitrectomy

    Directory of Open Access Journals (Sweden)

    Eduardo Dib

    2009-12-01

    Full Text Available O objetivo do artigo é apresentar os dados atuais da aplicação de corantes vitais durante cirurgia vitreorretiniana, "cromovitrectomia", bem como uma revisão da literatura atual sobre o assunto no tocante às técnicas de aplicação, indicações e complicações em cromovitrectomia. Um grande número de publicações tem abordado o perfil tóxico da indocianina verde na cromovitrectomia. Dados experimentais mostram uma toxicidade dose-dependente da mesma em várias populações de células retinianas. Novas gerações de corantes incluem: azul tripan, azul patente, acetato de triancinolona, infracianina verde, fluoresceína sódica, azul de bromofenol, acetato de fluorometolona e azul brilhante. Novos instrumentos podem permitir um corar seletivo de estruturas durante a vitrectomia. Este artigo mostra que o campo da cromovitrectomia está em plena expansão de pesquisas. Os corantes de primeira linha são a indocianina verde, infracianina verde e o azul brilhante. Azul patente, azul de bromofenol e azul tripan surgem como novos adjuvantes para melhor observação da membrana epirretiniana. Demais corantes que surgiram merecem maior investigação.The aim of this article is to present the current data with regard to the application of vital dyes during vitreoretinal surgery, "chromovitrectomy", as well as to overview the current literature regarding the properties of dyes, techniques of application, indications and complications in chromovitrectomy. A large body of published research has recently addressed the toxicity profile of indocyanine green for chromovitrectomy. Experimental data demonstrate dose-dependent toxicity of indocyanine green to various retinal cells. Newer generation vital dyes for chromovitrectomy include trypan blue, patent blue, triamcinolone acetonide, infracyanine green, sodium fluorescein, bromophenol blue, fluorometholone acetate and brilliant blue. Novel instruments may enable a selective painting of preretinal

  15. Success of intraoperative scintigraphic detection to complete eradicate of persistent osteoid osteoma

    International Nuclear Information System (INIS)

    Haddam, A.; Bsiss, A.; BenRais, N.; Lahlou, A.; Essahli, Y.; Boufetal; Lamzaf, O.; El Yaacoubi, M.

    2009-01-01

    The osteoid osteoma is a small benign, painful, bony tumour in which the treatment consists of a complete surgical ablation. The cases of recurrence often correspond to an incomplete surgical ablation. We report, in this work, the advantage of isotopic intraoperative marking for an accurate and complete excision of the pathological lesion in a young patient, during his surgical resumption after the short-term failure of the first intervention, which was accomplished without intraoperative location, and completed with a literature review. (authors)

  16. Intraoperative hyperventilation vs remifentanil during electrocorticography for epilepsy surgery - a case report

    DEFF Research Database (Denmark)

    Kjaer, Troels W; Madsen, F F; Moltke, F B

    2010-01-01

    different brain regions in the same patient. METHODS: Hyperventilation and ultra short acting opioid remifentanil were used separately as intraoperative precipitatants of seizure patterns, while recording from subdural and intraventricular electrodes in a patient with temporal lobe epilepsy. Two different...... ictal onset zones appeared in response to hyperventilation and remifentanil. Both zones were resected and the patient has remained essentially seizure free for 1 year. Furthermore, this is the first description of hyperventilation used as an intraoperative seizure precipitant in human focal epilepsy....

  17. Versatile intraoperative MRI in neurosurgery and radiology.

    Science.gov (United States)

    Yrjänä, S K; Katisko, J P; Ojala, R O; Tervonen, O; Schiffbauer, H; Koivukangas, J

    2002-03-01

    Several models for the application of intra-operative magnetic resonance imaging (IMRI) have recently been reported, most of them unique. Two fundamental issues need to be addressed: optimal use of the scanner to ensure a wide base for research, development and clinical application, and an organisational model that facilitates such use. While in our setting the IMRI project was initiated by the neurosurgeons, the need for wider use of the facilities was recognised since the beginning of the planning phase in 1996. An organisational model was developed that allowed for development of neurosurgical applications, radiological imaging, and radiological interventions and for the research and development work of the vendor. A resistive 0.23 T MR scanner was installed in a dedicated operating room environment. Unique to this scanner is the ability to turn off the magnet, allowing for normal OR activities and devices, and to turn on the magnet as needed with a relatively short six-minute ramp up time. A staged surgical technique was perfected, allowing for transfer of data to the neuronavigator outside the scanner during surgery. In neurosurgery, IMRI was used as one part of a neuronavigational system that included ultrasound imaging, intra-operative cortical stimulation during awake procedures, electrocorticography and two neuronavigators. 34 neurosurgical cases included 27 brain tumour resections, 5 brain tumour biopsies, 1 extirpation of an arterio-venous malformation, and 1 haematoma evacuation. The scanner could also be used for normal clinical imaging where obese patients, children, claustophobic patients and postoperative control examinations were the major groups. The radiologists performed 110 interventions, including bone and abdominal biopsies, nerve root infiltrations and local pain therapies, with the optical needle tracking system under continuous MRI guidance. The organisational model allowed frequent use of the facilities for both neurosurgery and radiology

  18. Intraoperative radiotherapy in early stage breast cancer: potential indications and evidence to date

    Science.gov (United States)

    Kirby, A M

    2015-01-01

    Following early results of recent studies of intraoperative radiotherapy (IORT) in the adjuvant treatment of patients with early breast cancer, the clinical utility of IORT is a subject of much recent debate within the breast oncology community. This review describes the intraoperative techniques available, the potential indications and the evidence to date pertaining to local control and toxicity. We also discuss any implications for current practice and future research. PMID:25734489

  19. Intraoperative Functional Mapping and Monitoring during Glioma Surgery

    Science.gov (United States)

    SAITO, Taiichi; MURAGAKI, Yoshihiro; MARUYAMA, Takashi; TAMURA, Manabu; NITTA, Masayuki; OKADA, Yoshikazu

    2015-01-01

    Glioma surgery represents a significant advance with respect to improving resection rates using new surgical techniques, including intraoperative functional mapping, monitoring, and imaging. Functional mapping under awake craniotomy can be used to detect individual eloquent tissues of speech and/or motor functions in order to prevent unexpected deficits and promote extensive resection. In addition, monitoring the patient’s neurological findings during resection is also very useful for maximizing the removal rate and minimizing deficits by alarming that the touched area is close to eloquent regions and fibers. Assessing several types of evoked potentials, including motor evoked potentials (MEPs), sensory evoked potentials (SEPs) and visual evoked potentials (VEPs), is also helpful for performing surgical monitoring in patients under general anesthesia (GA). We herein review the utility of intraoperative mapping and monitoring the assessment of neurological findings, with a particular focus on speech and the motor function, in patients undergoing glioma surgery. PMID:25744346

  20. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  1. OPTICAL COHERENCE TOMOGRAPHY OF ADIPOSE TISSUE AT PHOTODYNAMIC/PHOTOTHERMAL TREATMENT IN VITRO

    Directory of Open Access Journals (Sweden)

    IRINA YU. YANINA

    2013-04-01

    Full Text Available Temporal changes in structure and refractive-index distribution of adipose tissue at photodynamic/photothermal treatment were studied with OCT in vitro. Ethanol–water solutions of indocyanine green (ICG and brilliant green (BG were used for fat tissue staining. CW laser diode (808 nm and LED light source (442 and 597 nm were used for irradiation of stained tissue slices. The data received supporting the hypothesis that photodynamic/photothermal treatment, induces fat cell lipolysis during a certain period of time after light exposure.

  2. Strategy of Surgical Resection for Glioma Based on Intraoperative Functional Mapping and Monitoring

    Science.gov (United States)

    TAMURA, Manabu; MURAGAKI, Yoshihiro; SAITO, Taiichi; MARUYAMA, Takashi; NITTA, Masayuki; TSUZUKI, Shunsuke; ISEKI, Hiroshi; OKADA, Yoshikazu

    2015-01-01

    A growing number of papers have pointed out the relationship between aggressive resection of gliomas and survival prognosis. For maximum resection, the current concept of surgical decision-making is in “information-guided surgery” using multimodal intraoperative information. With this, anatomical information from intraoperative magnetic resonance imaging (MRI) and navigation, functional information from brain mapping and monitoring, and histopathological information must all be taken into account in the new perspective for innovative minimally invasive surgical treatment of glioma. Intraoperative neurofunctional information such as neurophysiological functional monitoring takes the most important part in the process to acquire objective visual data during tumor removal and to integrate these findings as digitized data for intraoperative surgical decision-making. Moreover, the analysis of qualitative data and threshold-setting for quantitative data raise difficult issues in the interpretation and processing of each data type, such as determination of motor evoked potential (MEP) decline, underestimation in tractography, and judgments of patient response for neurofunctional mapping and monitoring during awake craniotomy. Neurofunctional diagnosis of false-positives in these situations may affect the extent of resection, while false-negatives influence intra- and postoperative complication rates. Additionally, even though the various intraoperative visualized data from multiple sources contribute significantly to the reliability of surgical decisions when the information is integrated and provided, it is not uncommon for individual pieces of information to convey opposing suggestions. Such conflicting pieces of information facilitate higher-order decision-making that is dependent on the policies of the facility and the priorities of the patient, as well as the availability of the histopathological characteristics from resected tissue. PMID:26185825

  3. The Influence of Environmental Friendliness on Green Trust: The Mediation Effects of Green Satisfaction and Green Perceived Quality

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2015-07-01

    Full Text Available As global green trends became more prevalent, green marketing also developed into an important issue. Although prior literature explored the main factors affecting green trust, it was inconclusive as to how environmental friendliness could affect the green trust in green marketing. This study aims to focus on the positive influence of environmental friendliness on green trust, and explore the mediation effects of green satisfaction and green perceived quality. This study undertakes an empirical study by means of questionnaire survey. The respondents are consumers who have experience purchasing green products. This study applies structural equation modeling (SEM to test the hypotheses. The findings of this study indicate that (1 environmental friendliness has a significant positive impact on green satisfaction, green perceived quality, and green trust; (2 both green satisfaction and green perceived quality positively affect green trust; and (3 green satisfaction and green perceived quality partially mediate the positive relationship between environmental friendliness and green trust.

  4. Intraoperative Deaths at Ahmadu Bello University Teaching Hospital ...

    African Journals Online (AJOL)

    Nine cases of intraoperative deaths were recorded. Most of the deaths occurred among the gravely ill, inadequately prepared patients and patients whose operations were done in the late hours of the night. Conclusion: This tragedy is preventable by paying meticulous attention to details and careful patient selection and ...

  5. Study on intraoperative radiotherapy applying hyperthermia together with radiation sensitizers for progressive local carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Abe, M; Takahashi, M; Ono, K; Hiraoka, M [Kyoto Univ. (Japan). Faculty of Medicine

    1980-08-01

    Intraoperative radiotherapy for gastric cancer, colonic cancer, pancreatic cancer, cancer of the biliary tract, prostatic carcinoma, cerebral tumor, tumor of soft tissues, and osteosarcoma and its clinical results were described. Basic and clinical studies on effects of both hyperthermia and radiation sensitizers to elevate radiation sensitivity were also described, because effects of intraoperative radiotherapy were raised by applying hyperthermia and hypoxic cell sensitizers.

  6. Green power certification: environmental and consumer protection benefits of the Green-e programme

    Energy Technology Data Exchange (ETDEWEB)

    Wingate, M.; Hamrin, J. [Center for Resource Solutions (United States); Rabago, K. [Rocky Mountain Inst. (United States); Wiser, R. [Lawrence Berkeley National Lab. (United States)

    2000-06-01

    This article gives details of the Green-e environmental certification programme which certifies electricity generated from renewable energy sources in the US. This first non-profit certification programme originally was set up for California, and has now spread to other regions. The objectives of the Green-e programme, the need for the electricity product to meet minimum criteria to qualify, marketer requirements, verification of product claims, administration of the programme, and the second year programme results are discussed. The way in which the Green-e programme fits in with other programmes such as those set up by the state and federal customer protection agencies to help consumers select environmentally superior power is described.

  7. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  8. Intraoperative Hypoglossal Nerve Mapping During Carotid Endarterectomy: Technical Note.

    Science.gov (United States)

    Kojima, Atsuhiro; Saga, Isako; Ishikawa, Mami

    2018-05-01

    Hypoglossal nerve deficit is a possible complication caused by carotid endarterectomy (CEA). The accidental injury of the hypoglossal nerve during surgery is one of the major reasons for permanent hypoglossal nerve palsy. In this study, we investigated the usefulness of intraoperative mapping of the hypoglossal nerve to identify this nerve during CEA. Five consecutive patients who underwent CEA for the treatment of symptomatic or asymptomatic carotid artery stenosis were studied. A hand-held probe was used to detect the hypoglossal nerve in the operative field, and the tongue motor evoked potentials (MEPs) were recorded. The tongue MEPs were obtained in all the patients. The invisible hypoglossal nerve was successfully identified without any difficulty when the internal carotid artery was exposed. Intraoperative mapping was particularly useful for identifying the hypoglossal nerve when the hypoglossal nerve passed beneath the posterior belly of the digastric muscle. In 1 of 2 cases, MEP was also elicited when the ansa cervicalis was stimulated, although the resulting amplitude was much smaller than that obtained by direct stimulation of the hypoglossal nerve. Postoperatively, none of the patients presented with hypoglossal nerve palsy. Intraoperative hypoglossal nerve mapping enabled us to locate the invisible hypoglossal nerve during the exposure of the internal carotid artery accurately without retracting the posterior belly of the digastric muscle and other tissues in the vicinity of the internal carotid artery. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  10. Bilateral Dome-Shaped Macula with Serous Macular Detachment in a Child

    OpenAIRE

    Cebeci, Zafer; Kir, Nur

    2015-01-01

    Dome-shaped macula is a structural disorder and optical coherence tomography (OCT) helps us to confirm macular convexity. We describe the first case of bilateral dome-shaped macula in an 8-year-old boy with subretinal fluid. The patient was diagnosed using spectral-domain OCT and received indocyanine green angiography-guided half-fluence photodynamic therapy as treatment.

  11. The green building envelope : Vertical greening

    NARCIS (Netherlands)

    Ottelé, M.

    2011-01-01

    Planting on roofs and façades is one of the most innovative and fastest developing fields of green technologies with respect to the built environment and horticulture. This thesis is focused on vertical greening of structures and to the multi-scale benefits of vegetation. Vertical green can improve

  12. Effect and Outcome of Intraoperative Fluid Restriction in Living Liver Donor Hepatectomy.

    Science.gov (United States)

    Wang, Chih-Hsien; Cheng, Kwok-Wai; Chen, Chao-Long; Wu, Shao-Chun; Shih, Tsung-Hsiao; Yang, Sheng-Chun; Lee, Ying-En; Jawan, Bruno; Huang, Chiu-En; Juang, Sin-Ei; Huang, Chia-Jung

    2017-11-10

    BACKGROUND The purpose of this study was to evaluate the effect and outcome of intraoperative fluid restriction in living liver donor hepatectomy, regarding changes in intraoperative CVP levels, blood loss, and postoperative renal function. MATERIAL AND METHODS The charts of 167 patients were reviewed and analyzed retrospectively. Intraoperative central venous pressure levels, blood loss, fluids infused, and urine output per hour, before and after the liver allograft procurement, were calculated. Perioperative renal functions were also analyzed. RESULTS Fluid infused before and after liver allograft procurement was 3.21±1.5 and 9.0±3.9 mL/Kg/h and urine output was 1.5±0.7 and 1.8±1.4 mL/Kg/h, respectively. Intraoperative estimated blood loss was 91.3±78.9 mL. No patients required blood transfusion. Their preoperative and postoperative hemoglobin were 12.3±2.7 and 11.7±1.7 g/dL. CVP levels decreased gradually from 10.4±3.0 to a low of 8.1±1.9 mmHg at the time of transection of the liver parenchyma. Renal functions were not significantly affected based on the determination of BUN and creatinine levels. CONCLUSIONS The methods used to lower CVP are moderate and slow, with 2 main goals achieved: minimal blood loss (91.3±78.9 ml) and no blood transfusion. Furthermore, it did not have any negative effect on renal function.

  13. Altered intraoperative cerebrovascular reactivity in brain areas of high-grade glioma recurrence.

    Science.gov (United States)

    Fierstra, Jorn; van Niftrik, Bas; Piccirelli, Marco; Burkhardt, Jan Karl; Pangalu, Athina; Kocian, Roman; Valavanis, Antonios; Weller, Michael; Regli, Luca; Bozinov, Oliver

    2016-07-01

    Current MRI sequences are limited in identifying brain areas at risk for high grade glioma recurrence. We employed intraoperative 3-Tesla functional MRI to assess cerebrovascular reactivity (CVR) after high-grade glioma resection and analyzed regional CVR responses in areas of tumor recurrence on clinical follow-up imaging. Five subjects with high-grade glioma that underwent an intraoperative Blood Oxygen-Level Dependent (BOLD) MRI CVR examination and had a clinical follow-up of at least 18months were selected from a prospective database. For this study, location of tumor recurrence was spatially matched to the intraoperative imaging to assess CVR response in that particular area. CVR is defined as the percent BOLD signal change during repeated cycles of apnea. Of the 5 subjects (mean age 44, 2 females), 4 were diagnosed with a WHO grade III and 1 subject with a WHO grade IV glioma. Three subjects exhibited a tumor recurrence on clinical follow-up MRI (mean: 15months). BOLD CVR measured in the spatially matched area of tumor recurrence was on average 94% increased (range-32% to 183%) as compared to contralateral hemisphere CVR response, 1.50±0.81 versus 1.03±0.46 respectively (p=0.31). For this first analysis in a small cohort, we found altered intraoperative CVR in brain areas exhibiting high grade glioma recurrence on clinical follow-up imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Minimalism through intraoperative functional mapping.

    Science.gov (United States)

    Berger, M S

    1996-01-01

    Intraoperative stimulation mapping may be used to avoid unnecessary risk to functional regions subserving language and sensori-motor pathways. Based on the data presented here, language localization is variable in the entire population, with only certainty existing for the inferior frontal region responsible for motor speech. Anatomical landmarks such as the anterior temporal tip for temporal lobe language sites and the posterior aspect of the lateral sphenoid wing for the frontal lobe language zones are unreliable in avoiding postoperative aphasias. Thus, individual mapping to identify essential language sites has the greatest likelihood of avoiding permanent deficits in naming, reading, and motor speech. In a similar approach, motor and sensory pathways from the cortex and underlying white matter may be reliably stimulated and mapped in both awake and asleep patients. Although these techniques require an additional operative time and equipment nominally priced, the result is often gratifying, as postoperative morbidity has been greatly reduced in the process of incorporating these surgical strategies. The patients quality of life is improved in terms of seizure control, with or without antiepileptic drugs. This avoids having to perform a second costly operative procedure, which is routinely done when extraoperative stimulation and recording is done via subdural grids. In addition, an aggressive tumor resection at the initial operation lengthens the time to tumor recurrence and often obviates the need for a subsequent reoperation. Thus, intraoperative functional mapping may be best alluded to as a surgical technique that results in "minimalism in the long term".

  15. GREEN MANAGEMENT: THE REALITY OF BEING GREEN IN BUSINESS

    OpenAIRE

    Tran, Ben

    2009-01-01

    Green management and going green are not as clear cut and easy as hyped by the general media. While going ecologically green is indeed beneficial and appropriate, the process and procedure of becoming green is anything but easy. Firstly, turning green is largely not a legal requirement, but a voluntary process. Thus, even though LEED (which is by far the more publicly known green certification standard) governs the certification of the green management effort, it is not a compulsory condition...

  16. Intraoperative performance and longterm outcome of phacoemulsification in age-related cataract.

    Directory of Open Access Journals (Sweden)

    Dholakia Sheena

    2004-01-01

    Full Text Available PURPOSE: To evaluate intraoperative performance and longterm surgical outcome after phacoemulsification of age-related cataracts. METHODS: Prospective, observational, non-comparative study of 165 consecutive eyes undergoing phacoemulsification with nuclear sclerosis Grade I to III (Scale I to V. Preoperative evaluation included specular microscopy. Phacoemulsification was performed by a single surgeon using a standardised surgical technique under topical anaesthesia. Intraoperatively, effective phaco time (EPT, wound site thermal injury (WSTI, serious complications (eg. vitreous loss, posterior capsule rupture, zonulolysis and intraoperative posterior capsule opacification (plaque were evaluated. Postoperatively, posterior capsule opacification (PCO, Neodymium:YAG (Nd:YAG laser posterior capsulotomy rate, corneal endothelial count, best corrected visual acuity and cystoid macular oedema were evaluated. Eyes were examined at 6 months and then yearly for 3 years. RESULTS: Mean ages of 78 males and 87 females were 59.12 +/- 8.56 and 58.34 +/- 7.45 years respectively. EPT was 36 +/- 19 seconds and WSTI occurred in 7 eyes (4.7%. No serious intraocular complications occurred. Intraoperative posterior capsule opacification (plaque was present in 21 eyes (13.93%. Postoperatively, PCO occurred in 8 eyes (4.84% and Nd:YAG laser posterior capsulotomy was performed in 3 eyes (1.8%. Endothelial cell loss was 7.1% at 3 years follow-up. At the end of 3 years follow-up, 146 eyes (88.89% maintained a best corrected visual acuity of > or = 6/12. Cystoid macular oedema did not occur in any eye at 1 and 6 months′ follow-up. CONCLUSION: PCO rates and endothelial cell loss were acceptable. Consistent and reproducible outcome can be obtained after phacoemulsification of age related cataracts (grade I to III.

  17. Intraoperative Sensorcaine significantly improves postoperative pain management in outpatient reduction mammaplasty.

    Science.gov (United States)

    Culliford, Alfred T; Spector, Jason A; Flores, Roberto L; Louie, Otway; Choi, Mihye; Karp, Nolan S

    2007-09-15

    Breast reduction is one of the most frequently performed plastic surgical procedures in the United States; more than 160,500 patients underwent the procedure in 2005. Many outpatient reduction mammaplasty patients report the greatest postoperative discomfort in the first 48 hours. The authors' investigated the effect of intraoperative topical application of the long-acting local anesthetic agent bupivacaine (Sensorcaine or Marcaine) on postoperative pain, time to postanesthesia care unit discharge, and postoperative use of narcotic medication. In a prospective, randomized, single-blind trial, intraoperative use of Sensorcaine versus placebo (normal saline) was compared. Postoperative pain was quantified using the visual analogue scale, and time to discharge from the postanesthesia care unit was recorded. Patients documented their outpatient pain medication usage. Of the 37 patients enrolled in the study, 20 were treated with intraoperative topical Sensorcaine and 17 received placebo. Patients treated with Sensorcaine were discharged home significantly faster (2.9 hours versus 3.8 hours, p = 0.002). The control arm consistently had higher pain scores in the postanesthesia care unit (although not statistically significant) than the Sensorcaine group using the visual analogue scale system. Furthermore, patients receiving Sensorcaine required significantly less narcotic medication while recovering at home (mean, 3.5 tablets of Vicodin) than the control group (mean, 6.4 tablets; p = 0.001). There were no complications resulting from Sensorcaine usage. This prospective, randomized, single-blind study demonstrates that a single dose of intraoperative Sensorcaine provides a safe, inexpensive, and efficacious way to significantly shorten the length of postanesthesia care unit stay and significantly decrease postoperative opioid analgesic use in patients undergoing ambulatory reduction mammaplasty.

  18. Intraoperative closure of infant multiple muscular ventricular septal defects with Amplatzer occluder

    International Nuclear Information System (INIS)

    Liu Jinfen; Gao Wei; Zhu Zhongqun; Chen Huiwen; Zhang Yuqi

    2005-01-01

    Objective: To report the preliminary experience of intraoperative hybrid therapy for closure of multiple muscular ventricular septal defects (VSD) in a small infant. Methods: After median sternotomy, a AGA Amplatzer occluder was introduced through right ventricular surface to close 2 muscular ventricular septal defects under transesophageal echocardiographic guidance. Results: The infant survived after the treatment without residual shunting, and rehabilitated rapidly. Conclusions: Intraoperative hybrid therapy with combined surgical technique and interventional procedure for closure of multiple muscular VSD in small infant is a safe and effective method. (authors)

  19. Principles for Management of Intraoperative Acute Type A Aortic Dissection.

    Science.gov (United States)

    Gukop, Philemon; Chandrasekaran, Vankatachalam

    2015-12-01

    Intraoperative Type A aortic dissection is a rare pathology with incidence of 0.06-0.32%. It is associated with a high mortality between 30-50%. Some associated risk factors, including hypertension, enlarged aorta, peripheral vascular disease, advanced age, atheroma, and high arterial pressure on cardiopulmonary bypass, have been identified. Modification of these risk factors could reduce the incidence of this event. Prompt diagnosis and management, with the aid of intraoperative trans-esophageal echocardiography and/or epi-aortic ultrasound has been shown to reduce the mortality to 17%. We illustrate the principles of management of this pathology with the case of a 62-year-old female who developed acute Type A aortic dissection while undergoing minimally invasive mitral valve repair.

  20. Effects of steal-prone anatomy on intraoperative myocardial ischemia. The SPI Research Group.

    Science.gov (United States)

    Leung, J M; Hollenberg, M; O'Kelly, B F; Kao, A; Mangano, D T

    1992-11-01

    Our study objective was to determine whether the presence of steal-prone anatomy conferred an increased risk in the development of intraoperative myocardial ischemia. Coronary artery steal of collateral blood flow has been demonstrated for many vasodilators, including isoflurane, the most commonly used inhalational anesthetic agent in the United States. It has been postulated that patients with steal-prone anatomy (total occlusion of one coronary artery that is supplied distally by collateral flow from another coronary artery with a > or = 50% stenosis) may be particularly at risk for the development of intraoperative myocardial ischemia when an anesthetic with a vasodilator property is being administered. We evaluated the risk of myocardial ischemia under isoflurane anesthesia (vs. a high dose narcotic technique using sufentanil) using continuous intraoperative electrocardiography and transesophageal echocardiography in patients with and without steal-prone anatomy undergoing coronary artery bypass graft surgery. Sixty-two (33%) of the 186 patients had steal-prone anatomy: in 5 (8%) the collateral-supplying vessel was > or = 50% to 69% stenosed, in 24 (39%) it was > or = 70% to 89% stenosed and in 33 (53%) it was > or = 90% stenosed. The incidence of ischemia (transesophageal echocardiography or intraoperative electrocardiography, or both) was similar in patients with and without steal-prone coronary anatomy (18 [29%] of 62 patients vs. 39 [31%] of 124 patients, p = 0.87, 95% confidence interval = -0.13 to 0.17). The incidence of intraoperative ischemia was similar in patients who received isoflurane or sufentanil anesthesia (20 [32%] of 62 patients vs. 37 [30%] of 124 patients, p = 0.87). The incidence of tachycardia and hypotension was low (increases in heart rate = 9.8%, and decreases in systolic blood pressure = 10.8% of total monitoring time during the prebypass period compared with preoperative baseline values). The incidence of adverse cardiac outcome was

  1. Value of intraoperative radiotherapy in locally advanced rectal cancer

    NARCIS (Netherlands)

    Ferenschild, Floris T. J.; Vermaas, Maarten; Nuyttens, Joost J. M. E.; Graveland, Wilfried J.; Marinelli, Andreas W. K. S.; van der Sijp, Joost R.; Wiggers, Theo; Verhoef, Cornelis; Eggermont, Alexander M. M.; de Wilt, Johannes H. W.

    PURPOSE: This study was designed to analyze the results of a multimodality treatment using preoperative radiotherapy, followed by surgery and intraoperative radiotherapy in patients with primary locally advanced rectal cancer. METHODS: Between 1987 and 2002, 123 patients with initial unresectable

  2. Video-rate optical flow corrected intraoperative functional fluorescence imaging

    NARCIS (Netherlands)

    Koch, Maximilian; Glatz, Juergen; Ermolayev, Vladimir; de Vries, Elisabeth G. E.; van Dam, Gooitzen M.; Englmeier, Karl-Hans; Ntziachristos, Vasilis

    Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and

  3. Alteration of the threshold stimulus for intraoperative brain mapping via use of antiepileptic medications

    Directory of Open Access Journals (Sweden)

    John W. Amburgy, MD

    2015-03-01

    Full Text Available Intraoperative seizures during awake craniotomy with cortical and subcortical mapping are a common occurrence. Patients are routinely treated preoperatively with anti-convulsive medications to reduce seizure occurrence. Historically these drugs have not been believed to significantly affect awake craniotomy procedures. We report a patient undergoing intraoperative mapping with differential response and seizure occurrence based upon antiepileptic drug usage. A 43 year old female presented with history of seizures, right sided hemiparesis, electrical sensations, and difficulty with language function. She was determined to have a mass lesion involving the left frontal and temporal lobes and subsequently elected to undergo resection by awake craniotomy with intraoperative mapping. A first attempt at lesion resection was performed after a missed dose of anti-convulsant medication (levetiracetam and was subsequently aborted because of repeated seizure activity. The threshold for seizure generation (1.75 mA was observed to be significantly lower than expected. Therapy was begun with both levetiracetam and phenytoin prior to a second attempted resection one week later. Thresholds for cortical motor response in the second operation were significantly higher than expected (> 9.0 mA, and no intraoperative seizure activity was observed. To our knowledge this is the first quantitative example of antiepileptic drugs affecting the current required for intraoperative mapping. This case highlights the potential for higher current requirements in patients preoperatively treated with high doses of antiepileptic drugs, as well as the importance of confirming adequate dosage of antiepileptic drugs in patients at an increased risk of seizure generation.

  4. Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Leisser, Christoph; Hackl, Christoph; Hirnschall, Nino; Luft, Nikolaus; Döller, Birgit; Draschl, Petra; Rigal, Karl; Findl, Oliver

    2016-04-01

    The aim of this study was to examine the quality of intraoperative visualization of the posterior hyaloid, epiretinal membrane (ERM), inner limiting membrane (ILM), and hyporeflective subfoveal zone with a commercially available, microscope-integrated spectral-domain OCT setup (mi-SD-OCT) (Rescan 700; Carl Zeiss Meditec AG, Germany). Twenty patients prospectively scheduled for pars plana vitrectomy with membrane peeling due to an idiopathic ERM were included. Standard 23-gauge, three-port pars plana vitrectomy with membrane peeling and staining of the ERM with a trypan blue-based chromovitrectomy dye was performed in all cases. Intraoperative SD-OCT was performed before and after peeling and visualization of the posterior hyaloid, ERM, ILM, and presence of subfoveal hyporeflective zones were examined. OCT follow-ups were performed 2 days and 3 months after surgery. The study was approved by the local ethics committee of the city of Vienna. Successful intraoperative visualization of ERM by mi-SD-OCT was possible in all cases. The posterior hyaloid and ILM could not be seen in the mi-SD-OCT scans, whereas an intraoperative subfoveal hyporeflective zone presented in 35% of cases. In 12.5% an independent subfoveal hyporeflective zone presented postoperatively. Visual acuity improved in 93.8% of patients after surgery. mi-SD-OCT appears to be a valuable tool for intraoperative visualization of the ERM and offers immediate visualization of retinal anatomy during peeling. Therefore, it adds to the understanding of intraoperative traumatic changes due to the peeling procedure. Copyright 2016, SLACK Incorporated.

  5. Intraoperative use of an open midfield MR scanner in the surgical treatment of cerebral gliomas; Intraoperative Nutzung eines offenen Mittelfeld-MRT waehrend der chirurgischen Therapie zerebraler Gliome

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Dietrich, J.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany); Trantakis, C. [Klinik und Poliklinik fuer Neurochirurgie, Univ. Leipzig (Germany)

    2003-07-01

    The aim of the present study was to evaluate the effectiveness of intraoperative MRI guidance in achieving more gross-total resection in case of primary brain tumors. We studied 12 patients with low-grade glioma and 19 patients with high-grade glioma who underwent surgery within a vertically open 0.5T MR system. After initial imaging, the resection was stopped at the point in which the neurosurgeon considered the resection complete by viewing the operation field. At this time, intraoperative MRI was repeated (''first control'') to identify any residual tumor. Areas of tumor-suspected tissue were localized and resected, with the exception of tissue adjacent to eloquent areas. Final imaging was carried out before closing the craniotomy. Comparison of ''first control'' and final imaging revealed a decrease of residual tumor volume from 32% to 4.3% in low-grade gliomas, and from 29% to 10% in high-grade gliomas. Intraoperative MRI allows a clear optimization of microsurgical resection of both low-grade and high-grade gliomas. (orig.) [German] Ziel der Untersuchung war es, die Effektivitaet des Einsatzes der intraoperativen MRT bei der Resektion gliogener Hirntumoren zu pruefen. 12 Patienten mit niedriggradigem Gliom und 19 Patienten mit Glioblastom wurden in einem vertikal offenen 0,5-T-MRT operiert. Nach der initialen Bildgebung erfolgte die Resektion bis zu dem Zeitpunkt, an dem der Neurochirurg kein Tumorgewebe mehr im OP-Situs abgrenzen konnte. Zu diesem Zeitpunkt erfolgte eine erneute MRT (''= erste Kontrolle'') zur Visualisierung nur MR-tomographisch darstellbaren Resttumors. Solche Areale wurden im OP-Situs lokalisiert und mit Ausnahme von Strukturen in der Naehe eloquenter Hirnareale reseziert. Vor Verschluss des Schaedels erfolgte eine abschliessende MR-Kontrolle. Durch Einsatz der intraoperativen MRT konnte eine Absenkung des relativen Resttumorvolumens von 32% auf 4,3% bei niediggradigen Gliomen und

  6. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

    Science.gov (United States)

    Hambright, D; Hellman, M; Barrack, R

    2018-01-01

    The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36-43. ©2018 The British Editorial Society of Bone & Joint Surgery.

  7. Study on intraoperative radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Uozumi, Akimasa

    1990-01-01

    Effects of a single large dose radiation on the brain of dogs were investigated for the purpose of determining the optimal dose and radiation field in intraoperative radiotherapy. The right parietal lobe of dogs (three groups, four dogs in each) were radiated at the dose of 30, 40 and 50 Gy respectively at the depth of 1.5 cm by 11 Nev electron beam with field size of 2 cm. CT and histopathological study were performed 2, 6, 12 and 24 months after radiation. L-hemiparesis developed 14 months after radiation in the 30 Gy group and 8 months in the 40 Gy group, 6 months in the 50 Gy group. All animals in the 40 Gy and 50 Gy groups died before 15 months of radiation. CT showed delayed radiation necrosis in all groups. Brain swelling and ventricular displacement in the radiated hemisphere and contralateral ventricular dilatation were depicted on plain CT. Diffuse heterogeneous contrast enhancement (CE) was observed on CE-CT. CT revealed disappearance of radiation necrosis in the 30 Gy group 24 months of radiation, suggesting that radiation necrosis may be dependent on the term after radiation. Histological findings of radiation necrosis were similar in all animals, and the vascular change preceding the parechymal necrosis was not observed. This supports the theory that the vascular alternation dose not play a major role in the production of radiation necrosis. The necrotic area grossly reflected the isodose curve and was observed in the radiation field with 15 to 20 Gy at the depth of 3 to 4.5 cm. Thus, the intraoperative radiotherapy should be planned on the basis of two such factors as electron beam energy and the field size, and the area out of the target should not be radiated at the dose of more than 15 Gy. The author believes that the information would contribute to safer and more effective application of intraoperative radiotherapy on malignant brain tumors. (J.P.N.) 63 refs

  8. Intraoperative hypothermia and its clinical outcomes in patients undergoing general anesthesia: National study in China.

    Directory of Open Access Journals (Sweden)

    Jie Yi

    Full Text Available Inadvertent intraoperative hypothermia (core temperature 2 h (OR = 2.60, 95% CI 2.09-3.24.The incidence of intraoperative hypothermia in China is high, and the rate of active warming of patients during operation is low. Hypothermia is associated with more postoperative shivering, increased ICU admissions, and longer postoperative hospital days.

  9. Outcomes of macular hole surgery in patients treated intraoperatively for retinal breaks and/or lattice degeneration.

    Science.gov (United States)

    Hwang, John; Escariao, Paulo; Iranmanesh, Reza; Tosi, Gian Marco; Chang, Stanley

    2007-01-01

    To assess the outcome of macular hole surgery in patients treated intraoperatively for retinal breaks and/or lattice degeneration. Retrospective review of patients who underwent macular hole surgery from September 1998 to August 2005. Outcomes in eyes that received intraoperative endolaser photocoagulation for retinal breaks and/or lattice degeneration were compared to outcomes in a case-matched control group without retinal breaks or lattice degeneration. A total of 235 consecutive macular hole surgery cases were reviewed. Twenty-four eyes from 24 patients received intraoperative endolaser photocoagulation for retinal breaks and/or lattice degeneration. Macular hole closure occurred in all case and control eyes without any incidence of postoperative retinal detachment. Best-corrected visual acuity improvement of at least three Snellen lines occurred in 100% of case eyes and 92% of control eyes. Outcomes of macular hole surgery in patients with retinal breaks and/or lattice degeneration are similar to outcomes in the overall population when these conditions are treated with intraoperative endolaser photocoagulation. Postoperative retinal detachment does not appear to be correlated with treated retinal tears and greater attention should focus on detecting and managing intraoperative breaks. In our hands, routine use panoramic viewing has replaced indirect ophthalmoscopy, by saving time, and reducing the risk of contamination.

  10. Repeated sugammadex reversal of muscle relaxation during lumbar spine surgery with intraoperative neurophysiological multimodal monitoring.

    Science.gov (United States)

    Errando, C L; Blanco, T; Díaz-Cambronero, Ó

    2016-11-01

    Intraoperative neurophysiological monitoring during spine surgery is usually acomplished avoiding muscle relaxants. A case of intraoperative sugammadex partial reversal of the neuromuscular blockade allowing adequate monitoring during spine surgery is presented. A 38 year-old man was scheduled for discectomy and vertebral arthrodesis throughout anterior and posterior approaches. Anesthesia consisted of total intravenous anesthesia plus rocuronium. Intraoperatively monitoring was needed, and the muscle relaxant reverted twice with low dose sugammadex in order to obtain adequate responses. The doses of sugammadex used were conservatively selected (0.1mg/kg boluses increases, total dose needed 0.4mg/kg). Both motor evoqued potentials, and electromyographic responses were deemed adequate by the neurophysiologist. If muscle relaxation was needed in the context described, this approach could be useful to prevent neurological sequelae. This is the first study using very low dose sugammadex to reverse rocuronium intraoperatively and to re-establish the neuromuscular blockade. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Intraoperative neuropathology of glioma recurrence: cell detection and classification

    Science.gov (United States)

    Abas, Fazly S.; Gokozan, Hamza N.; Goksel, Behiye; Otero, Jose J.; Gurcan, Metin N.

    2016-03-01

    Intraoperative neuropathology of glioma recurrence represents significant visual challenges to pathologists as they carry significant clinical implications. For example, rendering a diagnosis of recurrent glioma can help the surgeon decide to perform more aggressive resection if surgically appropriate. In addition, the success of recent clinical trials for intraoperative administration of therapies, such as inoculation with oncolytic viruses, may suggest that refinement of the intraoperative diagnosis during neurosurgery is an emerging need for pathologists. Typically, these diagnoses require rapid/STAT processing lasting only 20-30 minutes after receipt from neurosurgery. In this relatively short time frame, only dyes, such as hematoxylin and eosin (H and E), can be implemented. The visual challenge lies in the fact that these patients have undergone chemotherapy and radiation, both of which induce cytological atypia in astrocytes, and pathologists are unable to implement helpful biomarkers in their diagnoses. Therefore, there is a need to help pathologists differentiate between astrocytes that are cytologically atypical due to treatment versus infiltrating, recurrent, neoplastic astrocytes. This study focuses on classification of neoplastic versus non-neoplastic astrocytes with the long term goal of providing a better neuropathological computer-aided consultation via classification of cells into reactive gliosis versus recurrent glioma. We present a method to detect cells in H and E stained digitized slides of intraoperative cytologic preparations. The method uses a combination of the `value' component of the HSV color space and `b*' component of the CIE L*a*b* color space to create an enhanced image that suppresses the background while revealing cells on an image. A composite image is formed based on the morphological closing of the hue-luminance combined image. Geometrical and textural features extracted from Discrete Wavelet Frames and combined to classify

  12. Sustainable green urban planning: the Green Credit Tool

    NARCIS (Netherlands)

    Cilliers, E.J.; Diemont, E.; Stobbelaar, D.J.; Timmermans, W.

    2010-01-01

    Purpose – The Green Credit Tool is evaluated as a method to quantify the value of green-spaces and to determine how these green-space-values can be replaced or compensated for within urban spatial planning projects. Design/methodology/approach – Amersfoort Local Municipality created the Green Credit

  13. Fungal Microbiomes Associated with Green and Non-Green Building Materials.

    Science.gov (United States)

    Coombs, Kanistha; Vesper, Stephen; Green, Brett J; Yermakov, Mikhail; Reponen, Tiina

    2017-01-01

    Water-damaged buildings can lead to fungal growth and occupant health problems. Green building materials, derived from renewable sources, are increasingly utilized in construction and renovations. However, the question as to what fungi will grow on these green compared to non-green materials, after they get wet, has not been adequately studied. By determining what fungi grow on each type of material, the potential health risks can be more adequately assessed. In this study, we inoculated green and non-green pieces of ceiling tile, composite board, drywall, and flooring with indoor dust containing a complex mixture of naturally occurring fungi. The materials were saturated with water and incubated for two months in a controlled environment. The resulting fungal microbiomes were evaluated using ITS amplicon sequencing. Overall, the richness and diversity of the mycobiomes on each pair of green and non-green pieces were not significantly different. However, different genera dominated on each type of material. For example, Aspergillus spp. had the highest relative abundance on green and non-green ceiling tiles and green composite boards, but Peniophora spp. dominated the non-green composite board. In contrast, Penicillium spp. dominated green and non-green flooring samples. Green gypsum board was dominated by Phialophora spp. and Stachybotrys spp., but non-green gypsum board by Myrothecium spp. These data suggest that water-damaged green and non-green building materials can result in mycobiomes that are dominated by fungal genera whose member species pose different potentials for health risks.

  14. Intraoperative colonic irrigation in the management of left sided ...

    African Journals Online (AJOL)

    Objectives: To evaluate the safety and benefits of antegrade intraoperative colonic irrigation (lavage) and primary anastomosis, after colonic resection, in the treatment of left sided large bowel emergencies. Design: A prospective descriptive study. Setting: Jos University Teaching Hospital, Jos, Nigeria. Participants: Thirty ...

  15. Intra-operative maternal complications of emergency cesarean section done in advanced labor

    International Nuclear Information System (INIS)

    Nisa, M.U.

    2013-01-01

    Background: Emergency cesarean section done in advanced labor is a big challenge in obstetrics due to increased risk of intraoperative complications. In the last decade, a rapid increase in cesarean section done in advanced labor has been observed. Difficult deli-very of the fetal head during cesarean section carries a high risk of intraoperative complications like cervical and uterine tears, intra operative hemorrhage and trauma to the baby. Objectives: The purpose of this study is to find out the frequency and risk factors for intra-operative complications in emergency cesarean section done in advanced labor, so that appropriate management protocols can be planned to reduce these complications. Study Design: Prospective cohort study. Materials and Methods: This prospective study was carried out in Obstetrics and Gynecology Unit - 2 of Services Institute of Medical Sciences, Services Hospital, Lahore; from 1st January 2007 to 31st December 2007. All patients undergoing emergency cesarean sections done on laboring mothers were included in the study. The sample was divided into two groups; emergency C-section done in advanced labor as the study group and emergency C-section in early labor as the control group. Data were collected regarding age, parity, booked or unbooked status, indications for cesarean section, level of competence of operating surgeon, intra-operative complications and the risk factors for these complications. Data were recorded on a structured proforma and compared between the two groups. Statistical Analysis: Data were analyzed using computer programme SPSS Version 14 for windows applying student t-test for quantitative and chai square test for qualitative parameters. A p-value < 0.05 was used as statistically significant. Results: Out of 2064 total deliveries in the year 2007, 1290 (62.5%) were vaginal deliveries and 774 (37.5%) were C-Sections. Out of 774 C-Section, 174 (23%) were elective and 600 (77%) were emergency. Out of 600 emergency C

  16. Pediatric awake craniotomy and intra-operative stimulation mapping.

    Science.gov (United States)

    Balogun, James A; Khan, Osaama H; Taylor, Michael; Dirks, Peter; Der, Tara; Carter Snead Iii, O; Weiss, Shelly; Ochi, Ayako; Drake, James; Rutka, James T

    2014-11-01

    The indications for operating on lesions in or near areas of cortical eloquence balance the benefit of resection with the risk of permanent neurological deficit. In adults, awake craniotomy has become a versatile tool in tumor, epilepsy and functional neurosurgery, permitting intra-operative stimulation mapping particularly for language, sensory and motor cortical pathways. This allows for maximal tumor resection with considerable reduction in the risk of post-operative speech and motor deficits. We report our experience of awake craniotomy and cortical stimulation for epilepsy and supratentorial tumors located in and around eloquent areas in a pediatric population (n=10, five females). The presenting symptom was mainly seizures and all children had normal neurological examinations. Neuroimaging showed lesions in the left opercular (n=4) and precentral or peri-sylvian regions (n=6). Three right-sided and seven left-sided awake craniotomies were performed. Two patients had a history of prior craniotomy. All patients had intra-operative mapping for either speech or motor or both using cortical stimulation. The surgical goal for tumor patients was gross total resection, while for all epilepsy procedures, focal cortical resections were completed without any difficulty. None of the patients had permanent post-operative neurologic deficits. The patient with an epileptic focus over the speech area in the left frontal lobe had a mild word finding difficulty post-operatively but this improved progressively. Follow-up ranged from 6 to 27 months. Pediatric awake craniotomy with intra-operative mapping is a precise, safe and reliable method allowing for resection of lesions in eloquent areas. Further validations on larger number of patients will be needed to verify the utility of this technique in the pediatric population. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Parotid tumours: clinical and oncologic outcomes after microscope-assisted parotidectomy with intraoperative nerve monitoring

    OpenAIRE

    Carta, F.; N., Chuchueva; C., Gerosa; S., Sionis; R.A., Caria; R., Puxeddu

    2017-01-01

    SUMMARY Temporary and permanent facial nerve dysfunctions can be observed after parotidectomy for benign and malignant lesions. Intraoperative nerve monitoring is a recognised tool for the preservation of the nerve, while the efficacy of the operative microscope has been rarely stated. The authors report their experience on 198 consecutive parotidectomies performed on 196 patients with the aid of the operative microscope and intraoperative nerve monitoring. 145 parotidectomies were performed ...

  18. Identification of the pyramidal tract by neuronavigation based on intraoperative magnetic resonance tractography: correlation with subcortical stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro; Romano, Andrea; Calabria, Luigi Fausto; Coppola, Valeria; Fantozzi, Luigi Maria [University of Rome Sapienza, Department of Neuroradiology, Rome (Italy); Angelini, Albina; D' Andrea, Giancarlo; Mastronardi, Luciano; Ferrante, Luigi [University of Rome Sapienza, Department of Neurosurgery, Rome (Italy)

    2010-10-15

    To demonstrate the accuracy of magnetic resonance tractography (MRT) in localizing the cortical spinal tract (CST) close to brain tumours by using intraoperative electric subcortical stimulation. Nine patients with intra-axial brain tumours underwent neurosurgery. Planning was based on analysis of the course of streamlines compatible with the CST. After tumour removal, intraoperative MRT was reacquired. Sites at various distance from the CST were repeatedly stimulated to assess whether registered motor evoked potential (MEP) could be elicited. All patients were assessed clinically both pre- and postoperatively. The motor function was preserved in all patients. In all patients intraoperative MRT demonstrated shift of the bundle position caused by the surgical procedure. The distance between the estimated intraoperative CST and the point of elicited MEP was 1 cm or less in all nine patients. At distances greater than 2 cm, no patient reported positive MEP. Intraoperative MRT is a reliable technique for localization of CST. In all patients MEP were elicited by direct subcortical electrical stimulation at a distance below 1 cm from the CST as represented by MRT. Brain shifting might impact this evaluation since CST position may change during surgery in the range of 8 mm. (orig.)

  19. Identification of the pyramidal tract by neuronavigation based on intraoperative magnetic resonance tractography: correlation with subcortical stimulation

    International Nuclear Information System (INIS)

    Bozzao, Alessandro; Romano, Andrea; Calabria, Luigi Fausto; Coppola, Valeria; Fantozzi, Luigi Maria; Angelini, Albina; D'Andrea, Giancarlo; Mastronardi, Luciano; Ferrante, Luigi

    2010-01-01

    To demonstrate the accuracy of magnetic resonance tractography (MRT) in localizing the cortical spinal tract (CST) close to brain tumours by using intraoperative electric subcortical stimulation. Nine patients with intra-axial brain tumours underwent neurosurgery. Planning was based on analysis of the course of streamlines compatible with the CST. After tumour removal, intraoperative MRT was reacquired. Sites at various distance from the CST were repeatedly stimulated to assess whether registered motor evoked potential (MEP) could be elicited. All patients were assessed clinically both pre- and postoperatively. The motor function was preserved in all patients. In all patients intraoperative MRT demonstrated shift of the bundle position caused by the surgical procedure. The distance between the estimated intraoperative CST and the point of elicited MEP was 1 cm or less in all nine patients. At distances greater than 2 cm, no patient reported positive MEP. Intraoperative MRT is a reliable technique for localization of CST. In all patients MEP were elicited by direct subcortical electrical stimulation at a distance below 1 cm from the CST as represented by MRT. Brain shifting might impact this evaluation since CST position may change during surgery in the range of 8 mm. (orig.)

  20. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  1. Tumors in dogs exposed to experimental intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Johnstone, Peter A.S.; Laskin, William B.; De Luca, Anne Marie; Barnes, Margaret; Kinsella, Timothy J.; Sindelar, William F.

    1996-01-01

    Purpose: The frequency of radiation-induced neoplasms was determined in dogs enrolled in the National Cancer Institute canine trials of intraoperative radiotherapy (IORT). Methods and Materials: Twelve protocols assessing normal tissue response to IORT involved 238 dogs in a 15-year trial. Eighty-one dogs were followed for > 24 months postoperatively and were assessed for tumor development; 59 of these animals received IORT. Results: Twelve tumors occurred in the 59 dogs receiving IORT. Nine were in the IORT portals and were considered to be radiation induced. No tumors occurred in 13 sham animals or in 9 animals treated with external beam radiotherapy alone. The frequency of radiation-induced malignancies in dogs receiving IORT was 15%, and was 25% in animals receiving ≥ 25 Gy IORT. Frequency of all tumors, including spontaneous lesions, was 20%. Conclusions: Intraoperative radiotherapy contributed to a high frequency of sarcoma induction in these dogs. Unknown to date in humans involved in clinical trials of IORT, this potential complication should be looked for as long-term survivors are followed

  2. Surgery for traumatic facial nerve paralysis: does intraoperative monitoring have a role?

    Science.gov (United States)

    Ashram, Yasmine A; Badr-El-Dine, Mohamed M K

    2014-09-01

    The use of intraoperative facial nerve (FN) monitoring during surgical decompression of the FN is underscored because surgery is indicated when the FN shows more than 90 % axonal degeneration. The present study proposes including intraoperative monitoring to facilitate decision taking and provide prognostication with more accuracy. This prospective study was conducted on ten patients presenting with complete FN paralysis due to temporal bone fracture. They were referred after variable time intervals for FN exploration and decompression. Intraoperative supramaximal electric stimulation (2-3 mA) of the FN was attempted in all patients both proximal and distal to the site of injury. Postoperative FN function was assessed using House-Brackmann (HB) scale. All patients had follow-up period ranging from 7 to 42 months. Three different patterns of neurophysiological responses were characterized. Responses were recorded proximal and distal to the lesion in five patients (pattern 1); only distal to the lesion in two patients (pattern 2); and neither proximal nor distal to the lesion in three patients (pattern 3). Sporadic, mechanically elicited EMG activity was recorded in eight out of ten patients. Patients with pattern 1 had favorable prognosis with postoperative function ranging between grade I and III. Pattern 3 patients showing no mechanically elicited activity had poor prognosis. Intraoperative monitoring affects decision taking during surgery for traumatic FN paralysis and provides prognostication with sufficient accuracy. The detection of mechanically elicited EMG activity is an additional sign predicting favorable outcome. However, absence of responses did not alter surgeon decision when the nerve was found evidently intact.

  3. Rapid and accurate intraoperative pathological diagnosis by artificial intelligence with deep learning technology.

    Science.gov (United States)

    Zhang, Jing; Song, Yanlin; Xia, Fan; Zhu, Chenjing; Zhang, Yingying; Song, Wenpeng; Xu, Jianguo; Ma, Xuelei

    2017-09-01

    Frozen section is widely used for intraoperative pathological diagnosis (IOPD), which is essential for intraoperative decision making. However, frozen section suffers from some drawbacks, such as time consuming and high misdiagnosis rate. Recently, artificial intelligence (AI) with deep learning technology has shown bright future in medicine. We hypothesize that AI with deep learning technology could help IOPD, with a computer trained by a dataset of intraoperative lesion images. Evidences supporting our hypothesis included the successful use of AI with deep learning technology in diagnosing skin cancer, and the developed method of deep-learning algorithm. Large size of the training dataset is critical to increase the diagnostic accuracy. The performance of the trained machine could be tested by new images before clinical use. Real-time diagnosis, easy to use and potential high accuracy were the advantages of AI for IOPD. In sum, AI with deep learning technology is a promising method to help rapid and accurate IOPD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Multimodal treatment utilizing intraoperative radiotherapy for advanced cancer of the pancreas

    International Nuclear Information System (INIS)

    Onodera, Tokio

    1982-01-01

    A multimodal treatment was consisted of intraoperative radiation, external radiation, by-pass operation, chemotherapy and total parenteral nutrition if necessary to cover decreased oral-intake. Thirty-three cases were subjected to this therapy for 6 years. The stage of the tumors varied from a localized tumor in the pancreas to a huge tumor with multiple metastases, though the latter abandoned recently to be contraindication to this therapy. At laparotomy, a high energy electron beam was irradiated to the tumor with a dosage of 3,000 rad using a 20 MeV Betatron. The tumor was carefully prepared in order to avoid irradiating the duodenum and stomach. Choledochojejunostomy and gastrojejunostomy were performed in almost all of patients with cancer of head of pancreas. In some patients, external radiation was added with a dosage of 3,000 rad by linear X-ray. After radiotherapy, chemotherapy employing 5-FU or FT-207 was continued including. The survival time after this therapy was varied mainly according to the stages of the tumor. In patients with multiple metastasis to the liver or peritoneal dissemination, no remarkable effects were obtained by this therapy. On the otherhand, among 14 patients with localized tumor in the pancreas, 7 survived more than one year and the mean survival time of treated patients was nevershorter than that of patients who received resection of the tumor. Most of the treated patients could spend at home until their condition became critical, because by-pass operation could overcome jaundice or the duodenal stenosis and intraoperative radiation could palliate the pain of cancer of pancreas. Tumor effect of intraoperative radiation was confirmed by both of the second laporatomy for twice intraoperative radiation and laparatomy. (author)

  5. Appropriateness of Intra-Operative Blood Transfusion In Children at ...

    African Journals Online (AJOL)

    Background: The decision to transfuse intra-operatively is based on preoperative haemoglobin (Hb), estimated blood loss and physiological variables. The visual estimate of blood loss is notoriously unreliable especially with small volumes of blood losses in children. Objectives :We sought therefore to determine the ...

  6. Comparison of esophagogastric junction distensibility changes during POEM and Heller myotomy using intraoperative FLIP.

    Science.gov (United States)

    Teitelbaum, Ezra N; Boris, Lubomyr; Arafat, Fahd O; Nicodème, Frédéric; Lin, Zhiyue; Kahrilas, Peter J; Pandolfino, John E; Soper, Nathaniel J; Hungness, Eric S

    2013-12-01

    Peroral endoscopic myotomy (POEM) is a novel endoscopic surgical procedure for the treatment of achalasia. The comparative effects of POEM and laparoscopic Heller myotomy (LHM) on esophagogastric junction (EGJ) physiology are unknown. A novel measurement catheter, the functional lumen imaging probe (FLIP), allows for intraoperative evaluation of EGJ compliance by measuring luminal geometry and pressure during volume-controlled distensions. Distensibility index (DI) (defined as the minimum cross-sectional area at the EGJ divided by pressure) was measured with FLIP intraoperatively in patients undergoing LHM and POEM. Separate measurements were taken after each operative step. During LHM, measurements were performed after: (1) induction of anesthesia, (2) insufflation of pneumoperitoneum, (3) hiatal dissection and esophageal mobilization, (4) myotomy, (5) partial fundoplication, and (6) deinsufflation. During POEM, they were performed after: (1) induction of anesthesia, (2) submucosal tunnel creation, and (3) myotomy. Eleven LHM and 14 POEM patients underwent intraoperative FLIP. Baseline DI was similar between groups. LHM resulted in an overall increase in mean DI (pre 1.4 vs. post 7.6 mm(2)/mmHg, using a 40-ml distension volume; p Myotomy caused an increase in DI. Partial fundoplication (6 Toupet, 5 Dor) caused a decrease in DI, and deinsufflation caused an increase in DI. POEM also resulted in an overall increase in mean DI (pre 1.4 vs. post 7.9 mm(2)/mmHg; p myotomy caused increases in DI. When overall changes were compared, there were no differences in the amount of DI increase between LHM and POEM. POEM and LHM result in a similar improvement in EGJ distensibility intraoperatively. Further study is needed to correlate intraoperative FLIP measurements with postoperative symptomatic and physiologic outcomes.

  7. Intraoperative and postoperative risk factors for anastomotic leakage and pneumonia after esophagectomy for cancer.

    Science.gov (United States)

    Goense, L; van Rossum, P S N; Tromp, M; Joore, H C; van Dijk, D; Kroese, A C; Ruurda, J P; van Hillegersberg, R

    2017-01-01

    Morbidity and mortality after esophagectomy are often related to anastomotic leakage or pneumonia. This study aimed to assess the relationship of intraoperative and postoperative vital parameters with anastomotic leakage and pneumonia after esophagectomy. Consecutive patients who underwent transthoracic esophagectomy with cervical anastomosis for esophageal cancer from January 2012 to December 2013 were analyzed. Univariable and multivariable logistic regression analyses were used to determine potential associations of hemodynamic and respiratory parameters with anastomotic leakage or pneumonia. From a total of 82 included patients, 19 (23%) developed anastomotic leakage and 31 (38%) experienced pneumonia. The single independent factor associated with an increased risk of anastomotic leakage in multivariable analysis included a lower minimum intraoperative pH (OR 0.85, 95% CI 0.77-0.94). An increased risk of pneumonia was associated with a lower mean arterial pressure (MAP) in the first 12 hours after surgery (OR 0.93, 95% CI 0.86-0.99) and a higher maximum intraoperative pH (OR 1.14, 95% CI 1.02-1.27). Interestingly, no differences were noted for the MAP and inotrope requirement between patients with and without anastomotic leakage. A lower minimum intraoperative pH (below 7.25) is associated with an increased risk of anastomotic leakage after esophagectomy, whereas a lower postoperative average MAP (below 83 mmHg) and a higher intraoperative pH (above 7.34) increase the risk of postoperative pneumonia. These parameters indicate the importance of setting strict perioperative goals to be protected intensively. © International Society for Diseases of the Esophagus 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Extirpation of a cranial lesion radio guided by scintigraphy and intraoperative detection

    International Nuclear Information System (INIS)

    Concha Julio, Enrique; Basuri, Luciano; Otayza, Felipe; Neubauer, Sonia; Mena, Ismael; Arteaga, Maria Paz

    2005-01-01

    A skull lesion may be difficult to localize, specially a small one that is not evident on the external surface. In this paper, we describe the localization and extirpation aided by intraoperative radio guidance of a 2 cm lesion compromising the internal aspect of the posterior temporal bone. The radiological expression of this lesion was poor, both on the plain radiograph's and on the computed tomography, making the intraoperative radiology and the navigation aided by computed tomography useless. The lesion was extirpated in block and the skull repaired. The biopsy confirmed a Paget's disease. There were not surgical complications (au)

  9. Green Building Pro-Environment Behaviors: Are Green Users Also Green Buyers?

    Directory of Open Access Journals (Sweden)

    Xiaohuan Xie

    2017-09-01

    Full Text Available Pro-environment behaviors play a key role in advancing the development of green buildings. This study investigated the link between two green building pro-environment behaviors that require dissimilar resources: energy savings that do not require money in order to be more environmentally friendly and willingness to pay that involves economic resources including spending money in order to be more environmentally friendly. This study points out that the two pro-environment behaviors can be positively linked to each other. People who behave in an environmentally friendly manner at work would also be likely to pay an extra cost for a green building when buying a new home. The consistency of the two pro-environment behaviors can be explained by their common environmental beliefs: limits to growth and eco-crisis. The green building movement should prioritize pro-environmental behaviors and associated environmental beliefs to support green building policies, guidelines, and tools.

  10. Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Zhikui Wei

    2015-06-01

    Full Text Available The accurate and efficient localization of underlying vascular lesions is crucial for prompt and definitive treatment of subarachnoid hemorrhage (SAH. To demonstrate the utility and feasibility of intraoperative C-arm angiography in cerebrovascular emergencies, we report five cases of high grade SAH and/or intracerebral hemorrhage (ICH where intraoperative diagnostic C-arm angiography was safely and effectively utilized. Initial evaluations of all patients included a non-contrast head CT scan, which was followed by urgent decompressive hemicraniectomy as a life-saving measure in the presence of markedly elevated intracranial pressure. Further diagnostic evaluations were performed intraoperatively using a multi-purpose C-arm angiography system. The C-arm angiography findings greatly aided the intraoperative planning and led to definitive treatments in four cases of SAH by elucidating the underlying neurovascular lesions. With this treatment strategy, two of the patients made moderately good recoveries from their SAH and/or ICH with a Glasgow outcome score (GOS of 4. Three of the patients expired despite maximal therapy mostly due to unfavorable presenting grade. These results suggest that C-arm angiography is a reasonable diagnostic and surgical planning tool for selected patients with high grade diffuse SAH who require immediate decompression.

  11. A meta-analysis of intraoperative factors associated with ...

    African Journals Online (AJOL)

    ... 95% 1.9-26), new onset atrial fibrillation (OR 6.6, 95% CI 2.5-20), hypothermia (OR 2.2, 95% CI 1.1-5) and remote ischaemic preconditioning (OR 0.22, 95% CI 0.07-0.67). None of these studies controlled for blood transfusion. Conclusion: Both surgical and haemodynamic intraoperative events significantly increased the ...

  12. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  13. Intraoperative Scintigraphy Using a Large Field-of-View Portable Gamma Camera for Primary Hyperparathyroidism: Initial Experience

    Directory of Open Access Journals (Sweden)

    Nathan C. Hall

    2015-01-01

    Full Text Available Background. We investigated a novel technique, intraoperative 99 mTc-Sestamibi (MIBI imaging (neck and excised specimen (ES, using a large field-of-view portable gamma camera (LFOVGC, for expediting confirmation of MIBI-avid parathyroid adenoma removal. Methods. Twenty patients with MIBI-avid parathyroid adenomas were preoperatively administered MIBI and intraoperatively imaged prior to incision (neck and immediately following resection (neck and/or ES. Preoperative and intraoperative serum parathyroid hormone monitoring (IOPTH and pathology (path were also performed. Results. MIBI neck activity was absent and specimen activity was present in 13/20 with imaging after initial ES removal. In the remaining 7/20 cases, residual neck activity and/or absent ES activity prompted excision of additional tissue, ultimately leading to complete hyperfunctioning tissue excision. Postexcision LFOVGC ES imaging confirmed parathyroid adenoma resection 100% when postresection imaging qualitatively had activity (ES and/or no activity (neck. The mean ± SEM time saving using intraoperative LFOVGC data to confirm resection versus first IOPTH or path result would have been 22.0 ± 2 minutes (specimen imaging and 26.0 ± 3 minutes (neck imaging. Conclusion. Utilization of a novel real-time intraoperative LFOVGC imaging approach can provide confirmation of MIBI-avid parathyroid adenoma removal appreciably faster than IOPTH and/or path and may provide a valuable adjunct to parathyroid surgery.

  14. Transsphenoidal pituitary resection with intraoperative MR guidance: preliminary results

    Science.gov (United States)

    Pergolizzi, Richard S., Jr.; Schwartz, Richard B.; Hsu, Liangge; Wong, Terence Z.; Black, Peter M.; Martin, Claudia; Jolesz, Ferenc A.

    1999-05-01

    The use of intraoperative MR image guidance has the potential to improve the precision, extent and safety of transsphenoidal pituitary resections. At Brigham and Women's Hospital, an open-bore configuration 0.5T MR system (SIGNA SP, GE Medical Systems, Milwaukee, WI) has been used to provide image guidance for nine transsphenoidal pituitary adenoma resections. The intraoperative MR system allowed the radiologist to direct the surgeon toward the sella turcica successfully while avoiding the cavernous sinus, optic chiasm and other sensitive structures. Imaging performed during the surgery monitored the extent of resection and allowed for removal of tumor beyond the surgeon's view in five cases. Dynamic MR imaging was used to distinguish residual tumor from normal gland and postoperative changes permitting more precise tumor localization. A heme-sensitive long TE gradient echo sequence was used to evaluate for the presence of hemorrhagic debris. All patients tolerated the procedure well without significant complications.

  15. Real-time Near-infrared Virtual Intraoperative Surgical Photoacoustic Microscopy

    Directory of Open Access Journals (Sweden)

    Changho Lee

    2015-09-01

    Full Text Available We developed a near infrared (NIR virtual intraoperative surgical photoacoustic microscopy (NIR-VISPAM system that combines a conventional surgical microscope and an NIR light photoacoustic microscopy (PAM system. NIR-VISPAM can simultaneously visualize PA B-scan images at a maximum display rate of 45 Hz and display enlarged microscopic images on a surgeon's view plane through the ocular lenses of the surgical microscope as augmented reality. The use of the invisible NIR light eliminated the disturbance to the surgeon's vision caused by the visible PAM excitation laser in a previous report. Further, the maximum permissible laser pulse energy at this wavelength is approximately 5 times more than that at the visible spectral range. The use of a needle-type ultrasound transducer without any water bath for acoustic coupling can enhance convenience in an intraoperative environment. We successfully guided needle and injected carbon particles in biological tissues ex vivo and in melanoma-bearing mice in vivo.

  16. Intraoperative management of ETT and LMA cufi pressures: a survey ...

    African Journals Online (AJOL)

    2008-07-16

    Jul 16, 2008 ... A study done by Stein et al. highlighted the inability of advanced life support ... Conclusion. There is increasing importance placed on quality assurance ... pressures – the worrying reality: a comparative audit of intra-operative.

  17. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    Science.gov (United States)

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  18. Green thunderstorms

    Science.gov (United States)

    Gallagher, Frank Woolsey, III

    Many people around the world have observed green light apparently emanating from severe thunderstorms, but until recently there has been no scientific study of the phenomenon. Green thunderstorms have been observed from time to time in association with deep convection or severe weather events. Some skeptics who have not personally observed a green thunderstorm suggest that they are some kind of illusion. The existence of green thunderstorms has been objectively demonstrated by recording spectra of light from thunderstorms using a handheld spectrophotometer. During the spring and summer of 1995 and the spring of 1996 numerous storms were observed and spectra of the light emanating from these storms were recorded. Observations were made both at the ground and aboard research aircraft. Furthermore, time series of spectra were recorded as the observed color of some storms changed from dark blue to a bluish-green. Several hypotheses have been advanced to explain the occurrence of green light in connection with severe storms. Fankhauser gave some observational support to the belief that green light from thunderstorms is possible and believed that the source of the light is from the blue sky penetrating thin regions in the clouds. Fraser believes that light from the setting sun, in combination with the process of scattering by atmospheric molecules, creates the green light associated with severe weather and the thunderstorm acts only as a black backdrop. Unfortunately, no cloud illuminated by the sun is black and the green airlight produced by the Fraser theory is in reality overwhelmed by light reflected by the cloud. Often the unusual coloration has been attributed to hail or to reflection of light from foliage on the ground. The quantitative measurements made during the observation period fail to support these assumptions. We have observed thunderstorms to be green over ground that was not green and we have observed blue thunderstorms over ground that was green

  19. Current Trends in Intraoperative Optical Imaging for Functional Brain Mapping and Delineation of Lesions of Language Cortex

    Science.gov (United States)

    Prakash, Neal; Uhleman, Falk; Sheth, Sameer A.; Bookheimer, Susan; Martin, Neil; Toga, Arthur W.

    2009-01-01

    Resection of a cerebral arteriovenous malformation (AVM), epileptic focus, or glioma, ideally has a prerequisite of microscopic delineation of the lesion borders in relation to the normal gray and white matter that mediate critical functions. Currently, Wada testing and functional magnetic resonance imaging (fMRI) are used for preoperative mapping of critical function, whereas electrical stimulation mapping (ESM) is used for intraoperative mapping. For lesion delineation, MRI and positron emission tomography (PET) are used preoperatively, whereas microscopy and histological sectioning are used intraoperatively. However, for lesions near eloquent cortex, these imaging techniques may lack sufficient resolution to define the relationship between the lesion and language function, and thus not accurately determine which patients will benefit from neurosurgical resection of the lesion without iatrogenic aphasia. Optical techniques such as intraoperative optical imaging of intrinsic signals (iOIS) show great promise for the precise functional mapping of cortices, as well as delineation of the borders of AVMs, epileptic foci, and gliomas. Here we first review the physiology of neuroimaging, and then progress towards the validation and justification of using intraoperative optical techniques, especially in relation to neurosurgical planning of resection AVMs, epileptic foci, and gliomas near or in eloquent cortex. We conclude with a short description of potential novel intraoperative optical techniques. PMID:18786643

  20. The diagnostic dilemma of intraoperative hyperpyrexia in a malaria ...

    African Journals Online (AJOL)

    Keywords: Intraoperative fever, Malaria, Malignant hyperthermia. ... paludisme devront être examiné et soigné de paludisme s'il est indiqué d'une manière préopératoire même s'il est ... West African Journal of Medicine Vol.22(1) 2003: 98-100 ...

  1. Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite.

    Science.gov (United States)

    Uhl, Eberhard; Zausinger, Stefan; Morhard, Dominik; Heigl, Thomas; Scheder, Benjamin; Rachinger, Walter; Schichor, Christian; Tonn, Jörg-Christian

    2009-05-01

    We report our preliminary experience in a prospective series of patients with regard to feasibility, work flow, and image quality using a multislice computed tomographic (CT) scanner combined with a frameless neuronavigation system (NNS). A sliding gantry 40-slice CT scanner was installed in a preexisting operating room. The scanner was connected to a frameless infrared-based NNS. Image data was transferred directly from the scanner into the navigation system. This allowed updating of the NNS during surgery by automated image registration based on the position of the gantry. Intraoperative CT angiography was possible. The patient was positioned on a radiolucent operating table that fits within the bore of the gantry. During image acquisition, the gantry moved over the patient. This table allowed all positions and movements like any normal operating table without compromising the positioning of the patient. For cranial surgery, a carbon-made radiolucent head clamp was fixed to the table. Experience with the first 230 patients confirms the feasibility of intraoperative CT scanning (136 patients with intracranial pathology, 94 patients with spinal lesions). After a specific work flow, interruption of surgery for intraoperative scanning can be limited to 10 to 15 minutes in cranial surgery and to 9 minutes in spinal surgery. Intraoperative imaging changed the course of surgery in 16 of the 230 cases either because control CT scans showed suboptimal screw position (17 of 307 screws, with 9 in 7 patients requiring correction) or that tumor resection was insufficient (9 cases). Intraoperative CT angiography has been performed in 7 cases so far with good image quality to determine residual flow in an aneurysm. Image quality was excellent in spinal and cranial base surgery. The system can be installed in a preexisting operating environment without the need for special surgical instruments. It increases the safety of the patient and the surgeon without necessitating a change

  2. Safe surgery: how accurate are we at predicting intra-operative blood loss?

    LENUS (Irish Health Repository)

    2012-02-01

    Introduction Preoperative estimation of intra-operative blood loss by both anaesthetist and operating surgeon is a criterion of the World Health Organization\\'s surgical safety checklist. The checklist requires specific preoperative planning when anticipated blood loss is greater than 500 mL. The aim of this study was to assess the accuracy of surgeons and anaesthetists at predicting intra-operative blood loss. Methods A 6-week prospective study of intermediate and major operations in an academic medical centre was performed. An independent observer interviewed surgical and anaesthetic consultants and registrars, preoperatively asking each to predict expected blood loss in millilitre. Intra-operative blood loss was measured and compared with these predictions. Parameters including the use of anticoagulation and anti-platelet therapy as well as intra-operative hypothermia and hypotension were recorded. Results One hundred sixty-eight operations were included in the study, including 142 elective and 26 emergency operations. Blood loss was predicted to within 500 mL of measured blood loss in 89% of cases. Consultant surgeons tended to underestimate blood loss, doing so in 43% of all cases, while consultant anaesthetists were more likely to overestimate (60% of all operations). Twelve patients (7%) had underestimation of blood loss of more than 500 mL by both surgeon and anaesthetist. Thirty per cent (n = 6\\/20) of patients requiring transfusion of a blood product within 24 hours of surgery had blood loss underestimated by more than 500 mL by both surgeon and anaesthetist. There was no significant difference in prediction between patients on anti-platelet or anticoagulation therapy preoperatively and those not on the said therapies. Conclusion Predicted intra-operative blood loss was within 500 mL of measured blood loss in 89% of operations. In 30% of patients who ultimately receive a blood transfusion, both the surgeon and anaesthetist significantly underestimate

  3. Green shipping management

    CERN Document Server

    Lun, Y H Venus; Wong, Christina W Y; Cheng, T C E

    2016-01-01

    This book presents theory-driven discussion on the link between implementing green shipping practices (GSP) and shipping firm performance. It examines the shipping industry’s challenge of supporting economic growth while enhancing environmental performance. Consisting of nine chapters, the book covers topics such as the conceptualization of green shipping practices (GSPs), measurement scales for evaluating GSP implementation, greening capability, greening and performance relativity (GPR), green management practice, green shipping network, greening capacity, and greening propensity. In view of the increasing quest for environment protection in the shipping sector, this book provides a good reference for firms to understand and evaluate their capability in carrying out green operations on their shipping activities.

  4. Pre- and intraoperative volume determination of craniopharyngioma cysts

    Energy Technology Data Exchange (ETDEWEB)

    Georgi, P.; Strauss, L.; Sturm, V.; Ostertag, H.; Sinn, H.; Rommel, T.

    1980-08-01

    Exact cystic volume measurement is a prerequisite to proper /sup 90/Y dosage in the therapy of intracavitary monocystic craniopharyngiomas. The method of intraoperative volume measurement by a radionuclide dilution technique is compared to results abtained by preoperative using computer tomography. Both methods gave congruous results. It is pointed out that gamma camera scintigrams are essential for the early detection of complications.

  5. Monte Carlo based simulation of LIAC intraoperative radiotherapy accelerator along with beam shaper applicator

    Directory of Open Access Journals (Sweden)

    N Heidarloo

    2017-08-01

    Full Text Available Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric characteristics of the electron beam produced by LIAC intraoperative radiotherapy accelerator in conjunction with this applicator have been evaluated through Monte Carlo simulation by MCNP code. The results showed that the electron beam produced by the beam shaper applicator would have the desirable dosimetric characteristics, so that the mentioned applicator can be considered for clinical purposes. Furthermore, the good agreement between the results of simulation and practical dosimetry, confirms the applicability of Monte Carlo method in determining the dosimetric parameters of electron beam  intraoperative radiotherapy

  6. Microscope-integrated intraoperative optical coherence tomography-guided small-incision lenticule extraction: New surgical technique.

    Science.gov (United States)

    Sharma, Namrata; Urkude, Jayanand; Chaniyara, Manthan; Titiyal, Jeewan S

    2017-10-01

    We describe the surgical technique of microscope-integrated intraoperative optical coherence tomography (OCT)-guided small-incision lenticule extraction. The technique enables manual tracking of surgical instruments and identification of the desired dissection plane. It also helps discern the relation between the dissector and the intrastromal lenticule. The dissection plane becomes hyperreflective on dissection, ensuring complete separation of the intrastromal lenticule from the overlying and underlying stroma. Inadvertent posterior plane entry, cap-lenticule adhesion, incomplete separation of the lenticule, creation of a false plane, and lenticule remnants may be recognized intraoperatively so corrective steps can be taken immediately. In cases with a hazy overlying cap, microscope-integrated intraoperative OCT enables localization and extraction of the lenticule. The technique is helpful for inexperienced surgeons, especially in cases with low amplitudes of refractive errors, ie, thin lenticules. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Comparison of Near-Infrared Imaging Camera Systems for Intracranial Tumor Detection.

    Science.gov (United States)

    Cho, Steve S; Zeh, Ryan; Pierce, John T; Salinas, Ryan; Singhal, Sunil; Lee, John Y K

    2018-04-01

    Distinguishing neoplasm from normal brain parenchyma intraoperatively is critical for the neurosurgeon. 5-Aminolevulinic acid (5-ALA) has been shown to improve gross total resection and progression-free survival but has limited availability in the USA. Near-infrared (NIR) fluorescence has advantages over visible light fluorescence with greater tissue penetration and reduced background fluorescence. In order to prepare for the increasing number of NIR fluorophores that may be used in molecular imaging trials, we chose to compare a state-of-the-art, neurosurgical microscope (System 1) to one of the commercially available NIR visualization platforms (System 2). Serial dilutions of indocyanine green (ICG) were imaged with both systems in the same environment. Each system's sensitivity and dynamic range for NIR fluorescence were documented and analyzed. In addition, brain tumors from six patients were imaged with both systems and analyzed. In vitro, System 2 demonstrated greater ICG sensitivity and detection range (System 1 1.5-251 μg/l versus System 2 0.99-503 μg/l). Similarly, in vivo, System 2 demonstrated signal-to-background ratio (SBR) of 2.6 ± 0.63 before dura opening, 5.0 ± 1.7 after dura opening, and 6.1 ± 1.9 after tumor exposure. In contrast, System 1 could not easily detect ICG fluorescence prior to dura opening with SBR of 1.2 ± 0.15. After the dura was reflected, SBR increased to 1.4 ± 0.19 and upon exposure of the tumor SBR increased to 1.8 ± 0.26. Dedicated NIR imaging platforms can outperform conventional microscopes in intraoperative NIR detection. Future microscopes with improved NIR detection capabilities could enhance the use of NIR fluorescence to detect neoplasm and improve patient outcome.

  8. Intra-operative 3-T MRI for paediatric brain tumours: challenges and perspectives

    International Nuclear Information System (INIS)

    Abernethy, L.J.; Avula, S.; Hughes, G.M.; Wright, E.J.; Mallucci, C.L.

    2012-01-01

    MRI is the ideal modality for imaging intracranial tumours. Intraoperative MRI (ioMRI) makes it possible to obtain scans during a neurosurgical operation that can aid complete macroscopic tumour resection - a major prognostic factor in the majority of brain tumours in children. Intra-operative MRI can also help limit damage to normal brain tissue. It therefore has the potential to improve the survival of children with brain tumours and to minimise morbidity, including neurological deficits. The use of ioMRI is also likely to reduce the need for second look surgery, and may reduce the need for chemotherapy and radiotherapy. High-field MRI systems provide better anatomical information and also enable effective utilisation of advanced MRI techniques such as perfusion imaging, diffusion tensor imaging, and magnetic resonance spectroscopy. However, high-field ioMRI facilities require substantial capital investment, and careful planning is required for optimal benefit. Safe ioMRI requires meticulous attention to detail and rigorous application of magnetic field safety precautions. Interpretation of ioMRI can be challenging and requires experience and understanding of artefacts that are common in the intra-operative setting. (orig.)

  9. Laparoscopy Instructional Videos: The Effect of Preoperative Compared With Intraoperative Use on Learning Curves.

    Science.gov (United States)

    Broekema, Theo H; Talsma, Aaldert K; Wevers, Kevin P; Pierie, Jean-Pierre E N

    Previous studies have shown that the use of intraoperative instructional videos has a positive effect on learning laparoscopic procedures. This study investigated the effect of the timing of the instructional videos on learning curves in laparoscopic skills training. After completing a basic skills course on a virtual reality simulator, medical students and residents with less than 1 hour experience using laparoscopic instruments were randomized into 2 groups. Using an instructional video either preoperatively or intraoperatively, both groups then performed 4 repetitions of a standardized task on the TrEndo augmented reality. With the TrEndo, 9 motion analysis parameters (MAPs) were recorded for each session (4 MAPs for each hand and time). These were the primary outcome measurements for performance. The time spent watching the instructional video was also recorded. Improvement in performance was studied within and between groups. Medical Center Leeuwarden, a secondary care hospital located in Leeuwarden, The Netherlands. Right-hand dominant medical student and residents with more than 1 hour experience operating any kind of laparoscopic instruments were participated. A total of 23 persons entered the study, of which 21 completed the study course. In both groups, at least 5 of 9 MAPs showed significant improvements between repetition 1 and 4. When both groups were compared after completion of repetition 4, no significant differences in improvement were detected. The intraoperative group showed significant improvement in 3 MAPs of the left-nondominant-hand, compared with one MAP for the preoperative group. No significant differences in learning curves could be detected between the subjects who used intraoperative instructional videos and those who used preoperative instructional videos. Intraoperative video instruction may result in improved dexterity of the nondominant hand. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc

  10. The value of the intra-operative clinical mechanical axis measurement in open-wedge valgus high tibial osteotomies

    NARCIS (Netherlands)

    van de Pol, G.J.; Verdonschot, Nicolaas Jacobus Joseph; van Kampen, A.

    2012-01-01

    Introduction: In high tibial osteotomies (HTO) the correction needs to be precise and intra-operative assessment is essential. The purpose of this study was to evaluate the use of the intra-operative clinical mechanical axis measurement and compare it to the post-operative weight bearing situation

  11. Green Consumerism : an Eco-Friendly Behaviour Form Through The Green Product Consumption and Green Marketing

    Directory of Open Access Journals (Sweden)

    Wiwik Handayani

    2017-09-01

    Full Text Available This research is referred to analyse the influence of consumer attitude of green product towards purchase intention. The consumer attitude of green product is a psychological tendencies that is expressed by evaluating a certain entity with some advantage or disadvantage considerations. The problem of this research is the low of cunsumer awareness to consume green product, because the lack to comprehend the importance of green product usage for health and eco-friendly. The purpose of this research is to test the influence of consumer attitude of green products towards purchase intention. Hypothesis testing using Partial Least Square (PLS. The result of analysis show that there is influence among consumer attitude of green product towards consumer purchase intention significantly.

  12. Unfolding Green Defense

    DEFF Research Database (Denmark)

    Larsen, Kristian Knus

    2015-01-01

    In recent years, many states have developed and implemented green solutions for defense. Building on these initiatives NATO formulated the NATO Green Defence Framework in 2014. The framework provides a broad basis for cooperation within the Alliance on green solutions for defense. This report aims...... to inform and support the further development of green solutions by unfolding how green technologies and green strategies have been developed and used to handle current security challenges. The report, initially, focuses on the security challenges that are being linked to green defense, namely fuel...... consumption in military operations, defense expenditure, energy security, and global climate change. The report then proceeds to introduce the NATO Green Defence Framework before exploring specific current uses of green technologies and green strategies for defense. The report concludes that a number...

  13. Sympathetic ophthalmia - histopathological correlation with fluorescein and indocyanine green angiography: case report Oftalmia simpática - correlação da histopatologia com a angiografia por fluoresceína e indocianina verde: relato de caso

    Directory of Open Access Journals (Sweden)

    Antônio Marcelo Barbante Casella

    2008-12-01

    Full Text Available This study correlates fluorescein angiography (FA and indocyanine green angiography (ICGA to histopathologic findings in a patient with sympathetic ophtalmia. A male with a perforated trauma in right eye presented after two months a decrease in visual acuity of the left eye. FA and ICGA were performed and the images were correlated with the histopathologic findings of the enucleated eye; FA showed background areas of homogeneous hypofluorescence in the arterial and venous phases, as well as areas of granular progressive hyperfluorescence and leakage from the optic disc. ICGA showed areas of hypofluorescence in the early and intermediate phases of the examination, which persisted until the late phase. During the early phase, there was also diffuse hypofluorescence caused by blockage that allowed observation of areas of partial choroidal circulation. The histopathology of the enucleated right eye showed diffuse choriocapillaris edema and inflammation of the choroids, focal areas of hyperplasia of the retinal pigment epithelium (RPE as well as foci of epithelioid cells located between the choroid and the RPE. Furthermore, lymphocytic infiltration of the episcleral veins and retinal detachment were present. The hyperfluorescence observed on FA was correlated to retinal detachment and optic nerve inflammation. The hypofluorescence noted on FA and ICGA corresponded to the presence of blocking inflammatory cells (Dalen-Fuchs-like nodules and to diffuse choriocapillaris edema.O objetivo deste relato de caso foi correlacionar achados da histopatologia com a angiografia por fluoresceína (AF e por indocianina verde (AIV em um paciente com oftalmia simpática. Após dois meses de trauma perfurante no olho direito, o paciente apresentou baixa acuidade visual no olho esquerdo (OE. A AF do OE mostrou áreas de hipofluorescência homogênea na fase arterial e venosa, áreas de progressiva hiperfluorescência granular e vazamento do disco. A AIV mostrou

  14. Persistent and automatic intraoperative 3D digitization of surfaces under dynamic magnifications of an operating microscope.

    Science.gov (United States)

    Kumar, Ankur N; Miga, Michael I; Pheiffer, Thomas S; Chambless, Lola B; Thompson, Reid C; Dawant, Benoit M

    2015-01-01

    One of the major challenges impeding advancement in image-guided surgical (IGS) systems is the soft-tissue deformation during surgical procedures. These deformations reduce the utility of the patient's preoperative images and may produce inaccuracies in the application of preoperative surgical plans. Solutions to compensate for the tissue deformations include the acquisition of intraoperative tomographic images of the whole organ for direct displacement measurement and techniques that combines intraoperative organ surface measurements with computational biomechanical models to predict subsurface displacements. The later solution has the advantage of being less expensive and amenable to surgical workflow. Several modalities such as textured laser scanners, conoscopic holography, and stereo-pair cameras have been proposed for the intraoperative 3D estimation of organ surfaces to drive patient-specific biomechanical models for the intraoperative update of preoperative images. Though each modality has its respective advantages and disadvantages, stereo-pair camera approaches used within a standard operating microscope is the focus of this article. A new method that permits the automatic and near real-time estimation of 3D surfaces (at 1 Hz) under varying magnifications of the operating microscope is proposed. This method has been evaluated on a CAD phantom object and on full-length neurosurgery video sequences (∼1 h) acquired intraoperatively by the proposed stereovision system. To the best of our knowledge, this type of validation study on full-length brain tumor surgery videos has not been done before. The method for estimating the unknown magnification factor of the operating microscope achieves accuracy within 0.02 of the theoretical value on a CAD phantom and within 0.06 on 4 clinical videos of the entire brain tumor surgery. When compared to a laser range scanner, the proposed method for reconstructing 3D surfaces intraoperatively achieves root mean square

  15. Persistent and automatic intraoperative 3D digitization of surfaces under dynamic magnifications of an operating microscope

    Science.gov (United States)

    Kumar, Ankur N.; Miga, Michael I.; Pheiffer, Thomas S.; Chambless, Lola B.; Thompson, Reid C.; Dawant, Benoit M.

    2014-01-01

    One of the major challenges impeding advancement in image-guided surgical (IGS) systems is the soft-tissue deformation during surgical procedures. These deformations reduce the utility of the patient’s preoperative images and may produce inaccuracies in the application of preoperative surgical plans. Solutions to compensate for the tissue deformations include the acquisition of intraoperative tomographic images of the whole organ for direct displacement measurement and techniques that combines intraoperative organ surface measurements with computational biomechanical models to predict subsurface displacements. The later solution has the advantage of being less expensive and amenable to surgical workflow. Several modalities such as textured laser scanners, conoscopic holography, and stereo-pair cameras have been proposed for the intraoperative 3D estimation of organ surfaces to drive patient-specific biomechanical models for the intraoperative update of preoperative images. Though each modality has its respective advantages and disadvantages, stereo-pair camera approaches used within a standard operating microscope is the focus of this article. A new method that permits the automatic and near real-time estimation of 3D surfaces (at 1Hz) under varying magnifications of the operating microscope is proposed. This method has been evaluated on a CAD phantom object and on full-length neurosurgery video sequences (~1 hour) acquired intraoperatively by the proposed stereovision system. To the best of our knowledge, this type of validation study on full-length brain tumor surgery videos has not been done before. The method for estimating the unknown magnification factor of the operating microscope achieves accuracy within 0.02 of the theoretical value on a CAD phantom and within 0.06 on 4 clinical videos of the entire brain tumor surgery. When compared to a laser range scanner, the proposed method for reconstructing 3D surfaces intraoperatively achieves root mean square

  16. INTRAOPERATIVE IRRADIATION OF THE CANINE PANCREAS - SHORT-TERM EFFECTS

    NARCIS (Netherlands)

    HEIJMANS, HJ; MEHTA, DM; KLEIBEUKER, JH; SLUITER, WJ; OLDHOFF, J; HOEKSTRA, HJ

    1993-01-01

    Intraoperative electron beam radiotherapy (IORT) is clinically used as a potential adjunctive treatment to surgery of locally advanced pancreatic and gastric cancer. The tolerance of the pancreas to IORT was studied in 15 adult beagles, divided in 3 groups of 5 beagles in which 25, 30 or 35 Gy IORT

  17. Intraoperative cell salvage in South Africa: Feasible, beneficial and ...

    African Journals Online (AJOL)

    More than one CS blood unit was available for transfusion in 66% of cases. No additional staff were required to operate the Cell Saver, which was successfully used by medical officers. Conclusions. This study showed that intraoperative CS use is feasible, has potential patient benefit by reducing blood bank blood ...

  18. Metaphysical green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    example is a tiny Danish summer house from 1918 . The second example is ‘House before House’ , in Tokyo. The third example is a prefabricated house ‘CHU’ . The analysis evaluates the characteristics of diverse tones of green – from green image to green sensation. The analysis is based on the original...... of Sensation of Green is created by a physical interaction between the language of space and the language of nature” The notion of Sensation of Green was developed through a previous study ‘Learning from the Summer House’ investigating the unique architectural characteristics of the Danish summer houses...... the Sensation of Green? Three existing examples are agents to this discussion. The first example is a Danish summer house. The other two are international urban examples. While the summer house articulates the original meaning of Sensation of Green, the urban examples illustrate its urban context. The first...

  19. Association between intraoperative hypotension and myocardial injury after vascular surgery

    NARCIS (Netherlands)

    van Waes, JAR; Van Klei, Wilton A.; Wijeysundera, Duminda N.; Van Wolfswinkel, Leo; Lindsay, Thomas F.; Beattie, W. Scott

    2016-01-01

    Background: Postoperative myocardial injury occurs frequently after noncardiac surgery and is strongly associated with mortality. Intraoperative hypotension (IOH) is hypothesized to be a possible cause. The aim of this study was to determine the association between IOH and postoperative myocardial

  20. Practicality of intraoperative teamwork assessments.

    Science.gov (United States)

    Phitayakorn, Roy; Minehart, Rebecca; Pian-Smith, May C M; Hemingway, Maureen W; Milosh-Zinkus, Tanya; Oriol-Morway, Danika; Petrusa, Emil

    2014-07-01

    High-quality teamwork among operating room (OR) professionals is a key to efficient and safe practice. Quantification of teamwork facilitates feedback, assessment, and improvement. Several valid and reliable instruments are available for assessing separate OR disciplines and teams. We sought to determine the most feasible approach for routine documentation of teamwork in in-situ OR simulations. We compared rater agreement, hypothetical training costs, and feasibility ratings from five clinicians and two nonclinicians with instruments for assessment of separate OR groups and teams. Five teams of anesthesia or surgery residents and OR nurses (RN) or surgical technicians were videotaped in simulations of an epigastric hernia repair where the patient develops malignant hyperthermia. Two anesthesiologists, one OR clinical RN specialist, one educational psychologist, one simulation specialist, and one general surgeon discussed and then independently completed Anesthesiologists' Non-Technical Skills, Non-Technical Skills for Surgeons, Scrub Practitioners' List of Intraoperative Non-Technical Skills, and Observational Teamwork Assessment for Surgery forms to rate nontechnical performance of anesthesiologists, surgeons, nurses, technicians, and the whole team. Intraclass correlations of agreement ranged from 0.17-0.85. Clinicians' agreements were not different from nonclinicians'. Published rater training was 4 h for Anesthesiologists' Non-Technical Skills and Scrub Practitioners' List of Intraoperative Non-Technical Skills, 2.5 h for Non-Technical Skills for Surgeons, and 15.5 h for Observational Teamwork Assessment for Surgery. Estimated costs to train one rater to use all instruments ranged from $442 for a simulation specialist to $6006 for a general surgeon. Additional training is needed to achieve higher levels of agreement; however, costs may be prohibitive. The most cost-effective model for real-time OR teamwork assessment may be to use a simulation technician

  1. Wave Change of Intraoperative Transcranial Motor-Evoked Potentials During Corrective Fusion for Syndromic and Neuromuscular Scoliosis.

    Science.gov (United States)

    Ando, Kei; Kobayashi, Kazuyoshi; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Nishida, Yoshihiro; Ishiguro, Naoki; Imagama, Shiro

    2018-03-29

    There is little information on intraoperative neuromonitoring during correction fusion surgery for syndromic scoliosis. To investigate intraoperative TcMEPs and conditions (body temperature and blood pressure) for syndromic scoliosis. The subjects were 23 patients who underwent 25 surgeries for corrective fusion using TcMEP. Patients were divided into groups based on a decrease (DA+) or no decrease (DA-) of the amplitude of the TcMEP waveform of ≥70%. The groups were compared for age, sex, disease, type of surgery, fusion area, operation time, estimated blood loss, body temperature, blood pressure, Cobb angle, angular curve (Cobb angle/number of vertebra), bending flexibility, correction rate, and recovery. The mean Cobb angles before and after surgery were 85.2° and 29.1°, giving a correction rate of 68.2%. There were 16 surgeries (64.0%) with intraoperative TcMEP wave changes. The DA+ and DA- groups had similar intraoperative conditions, but the short angular curve differed significantly between these groups. Amplitude deterioration occurred in 4 cases during first rod placement, in 8 during rotation, and in 3 during second rod placement after rotation. Seven patients had complete loss of TcMEP. However, most TcMEP changes recovered after pediclectomy or decreased correction. The preoperative angular curve differed significantly between patients with and without TcMEP changes (P corrective fusion, and all but one of these changes occurred during the correction procedure. The angular curve was a risk factor for intraoperative motor deficit.

  2. An update on the ocular phenotype in patients with pseudoxanthoma elasticum

    Directory of Open Access Journals (Sweden)

    Martin eGliem

    2013-04-01

    Full Text Available Pseudoxanthoma elasticum (PXE is an inherited multi-system disorder characterized by ectopic mineralization and fragmentation of elastic fibres in the skin, the elastic laminae of blood vessels and Bruch membrane in the eye. Biallelic mutations in the ABC transporter gene ABCC6 on chromosome 16 are responsible for the disease.The pathophysiology is incompletely understood. However, there is consent that a metabolic alteration leads to dysfunction in extracellular calcium homeostasis and subsequent calcification of connective tissues rich in elastic fibres. This review summarizes and aims at explaining the variety of phenotypic ocular findings in patients with PXE. Specialised imaging techniques including white light fundus photography, blue light autofluorescence, near-infrared confocal reflectance imaging, high resolution optical coherence tomography, fluorescein and indocyanin green angiography have revealed characteristic lesions at the ocular fundus of PXE patients. These include the classic signs of angioid streaks, peau d’orange, comet lesions and choroidal neovascularisations (CNV, but also the more recently recognised features such as chorioretinal atrophy, subretinal fluid independent from CNV, pattern dystrophy-like changes, debris accumulation under the retinal pigment epithelium, and a decreased fluorescence on late phase indocyanine green angiography.

  3. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  4. A case of lumbar pain after intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Wakako; Ogino, Takashi; Murakami, Koji; Nawano, Shigeru; Moriyama, Noriyuki; Ryu, Munemasa; Kawano, Nariaki

    1996-01-01

    We report a case of abnormal magnetic resonance imaging (MRI) findings after intraoperative radiotherapy. A 53-year-old woman with cancer of the papilla of Vater was treated with pancreatoduodenectomy and 20 Gy of intraoperative radiotherapy by electron beam to the tumor bed. Three months later the patient complained of lumbar pain. A change of signal intensity on MRI was detected in the anterior half of the vertebral body within the irradiated field. The signal was of high intensity but was not enhanced by Gd-DTPA on T1-weighted images, was isointense on T2-weighted images and of low intensity with the fat-suppression method. The radiation dose to the lumbar spine and the surrounding soft tissue was calculated to be 16 Gy. Histologic changes in bone after irradiation may include depletion of bone marrow cells and fat degeneration. The MRI findings were compatible with these changes. The radiation dose that can be tolerated by soft tissue is lower than that tolerated by bone. Therefore, late radiation injury of the soft tissue might have been the cause of the patient's lumbar pain. (author)

  5. The Influence of Consumers Perception of Green Products on Green Purchase Intention

    OpenAIRE

    Wilson Kong; Amran Harun; Rini Suryati Sulong; Jaratin Lily

    2014-01-01

    Green consumerism has increasingly received attention since the increased level of consumer awareness towards green products. Therefore, the aim of this paper had been to examine the influence of consumer perception of green products on green purchase intention. In this study, perception of green products was conceptualized as a multidimensional variable comprised of green corporate perception, eco-label, green advertising, green packaging, and green product value. By using a survey, a total ...

  6. Intraoperative haloperidol does not improve quality of recovery and postoperative analgesia

    Directory of Open Access Journals (Sweden)

    Amin Ebneshahidi

    2013-01-01

    Conclusion: Intraoperative small-dose IV haloperidol is effective against post-operative nausea and vomiting with no significant effect on overall QoR. It may also attenuate the analgesic effects of morphine PCA.

  7. Intraoperative computed tomography with integrated navigation system in spinal stabilizations.

    Science.gov (United States)

    Zausinger, Stefan; Scheder, Ben; Uhl, Eberhard; Heigl, Thomas; Morhard, Dominik; Tonn, Joerg-Christian

    2009-12-15

    STUDY DESIGN.: A prospective interventional case-series study plus a retrospective analysis of historical patients for comparison of data. OBJECTIVE.: To evaluate workflow, feasibility, and clinical outcome of navigated stabilization procedures with data acquisition by intraoperative computed tomography. SUMMARY OF BACKGROUND DATA.: Routine fluoroscopy to assess pedicle screw placement is not consistently reliable. Our hypothesis was that image-guided spinal navigation using an intraoperative CT-scanner can improve the safety and precision of spinal stabilization surgery. METHODS.: CT data of 94 patients (thoracolumbar [n = 66], C1/2 [n = 12], cervicothoracic instability [n = 16]) were acquired after positioning the patient in the final surgical position. A sliding gantry 40-slice CT was used for image acquisition. Data were imported to a frameless infrared-based neuronavigation workstation. Intraoperative CT was obtained to assess the accuracy of instrumentation and, if necessary, the extent of decompression. All patients were clinically evaluated by Odom-criteria after surgery and after 3 months. RESULTS.: Computed accuracy of the navigation system reached /=2 mm without persistent neurologic or vascular damage in 20/414 screws (4.8%) leading to immediate correction of 10 screws (2.4%). Control-iCT changed the course of surgery in 8 cases (8.5% of all patients). The overall revision rate was 8.5% (4 wound revisions, 2 CSF fistulas, and 2 epidural hematomas). There was no reoperation due to implant malposition. According to Odom-criteria all patients experienced a clinical improvement. A retrospective analysis of 182 patients with navigated thoracolumbar transpedicular stabilizations in the preiCT era revealed an overall revision rate of 10.4% with 4.4% of patients requiring screw revision. CONCLUSION.: Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization

  8. Comparative Study Of Intra-Operative Pelvimetry With Calipers And ...

    African Journals Online (AJOL)

    The pelvic measurement of patients who have had a caesarean section was done using Pelvic Calipers (intra-operative) and x-ray methods. In the former method, during Caesarean sections and after closure of the lower uterine segment incision, a pair of pelvic calipers was used to measure the true conjugate of the pelvis.

  9. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique.

    Science.gov (United States)

    Besharati Tabrizi, Leila; Mahvash, Mehran

    2015-07-01

    An augmented reality system has been developed for image-guided neurosurgery to project images with regions of interest onto the patient's head, skull, or brain surface in real time. The aim of this study was to evaluate system accuracy and to perform the first intraoperative application. Images of segmented brain tumors in different localizations and sizes were created in 10 cases and were projected to a head phantom using a video projector. Registration was performed using 5 fiducial markers. After each registration, the distance of the 5 fiducial markers from the visualized tumor borders was measured on the virtual image and on the phantom. The difference was considered a projection error. Moreover, the image projection technique was intraoperatively applied in 5 patients and was compared with a standard navigation system. Augmented reality visualization of the tumors succeeded in all cases. The mean time for registration was 3.8 minutes (range 2-7 minutes). The mean projection error was 0.8 ± 0.25 mm. There were no significant differences in accuracy according to the localization and size of the tumor. Clinical feasibility and reliability of the augmented reality system could be proved intraoperatively in 5 patients (projection error 1.2 ± 0.54 mm). The augmented reality system is accurate and reliable for the intraoperative projection of images to the head, skull, and brain surface. The ergonomic advantage of this technique improves the planning of neurosurgical procedures and enables the surgeon to use direct visualization for image-guided neurosurgery.

  11. Single-stage intraoperative transhepatic biliary stenting in patients with unresectable hepatobiliary pancreatic tumors.

    Science.gov (United States)

    Iwasaki, Yoshimi; Kubota, Keiichi; Kita, Junji; Katoh, Masato; Shimoda, Mitsugi; Sawada, Tokihiko; Iso, Yukihiro

    2013-02-01

    The current study was conducted to evaluate the safety and utility of intraoperative transhepatic biliary stenting (ITBS) in patients with unresectable malignant biliary obstruction (UMBO) diagnosed intraoperatively. In this study, 50 patients who underwent ITBS for UMBO between April 2001 and May 2009 were retrospectively reviewed. For 26 patients who underwent preoperative percutaneous transhepatic biliary drainage (PTBD), the expandable metallic stent (EMS) was inserted intraoperatively by the PTBD route in a single stage. For 24 patients, the intrahepatic bile ducts were intentionally dilated by injection of saline via the endoscopic nasobiliary drainage or the percutaneous transhepatic gallbladder drainage route, and the puncture was performed under intraoperative ultrasound guidance followed by guidewire and catheter insertion. Thereafter, the EMS was placed in the same manner. The initial postoperative complications and long-term results of ITBS were evaluated. In all cases, ITBS was technically successful. Stenting alone was performed in 22 patients and stenting combined with other procedures in 28 patients. Hospital mortality occurred for three patients (6 %), and complication-related mortality occurred in two cases (4 %). There were nine cases (18 %) of postoperative complications. The median survival time was 179 days, and the EMS patency time was 137 days. During the follow-up period, EMS occlusion occurred in 23 cases (46 %). Best supportive care was a significant independent risk factor for early mortality within 100 days after ITBS (p = 0.020, odds ratio, 9.398). Single-stage ITBS is feasible for palliation of UMBO and seems to have a low complication rate.

  12. Intraoperative dreams reported after general anaesthesia are not early interpretations of delayed awareness.

    Science.gov (United States)

    Samuelsson, P; Brudin, L; Sandin, R H

    2008-07-01

    Dreams are more frequently reported than awareness after surgery. We define awareness as explicit recall of real intraoperative events during anaesthesia. The importance of intraoperative dreaming is poorly understood. This study was performed to evaluate whether intraoperative dreams can be associated with, or precede, awareness. We also studied whether dreams can be related to case-specific parameters. A cohort of 6991 prospectively included patients given inhalational anaesthesia were interviewed for dreams and awareness at three occasions; before they left the post-anaesthesia care unit, days 1-3 and days 7-14 after the operation. Uni- and multivariate statistical relations between dreams, awareness and case-specific parameters were assessed. Two hundred and thirty-two of 6991 patients (3.3%) reported a dream. Four of those also reported awareness and remembered real events that were distinguishable from their dream. Awareness was 19 times more common among patients who after surgery reported a dream [1.7% vs. 0.09%; odds ratio (OR) 18.7; P=0.000007], but memories of dreams did not precede memories of awareness in any of the 232 patients reporting a dream. Unpleasant dreams were significantly more common when thiopentone was used compared with propofol (OR 2.22; P=0.005). Neutral or pleasant dreams were related to lower body mass index, female gender and shorter duration of anaesthesia. We found a statistically significant association between dreams reported after general anaesthesia and awareness, although intraoperative dreams were not an early interpretation of delayed awareness in any case. A typical dreamer in this study is a lean female having a short procedure.

  13. Intraoperative glucose management in children < 1 year or < 10 kg ...

    African Journals Online (AJOL)

    The intraoperative management of intravenous dextrose administration and blood glucose monitoring was at the discretion of the attending anaesthetists. Data collected included patient demographics, period of starvation, dose of dextrose administered and blood glucose measurements taken. Results: Nine infants had at ...

  14. Green Tourism

    OpenAIRE

    Hasan, Ali

    2014-01-01

    Green tourism is defined as environmentally friendly tourism activities with various focuses and meanings. In a broad term, green tourism is about being an environmentally friendly tourist or providing environmentally friendly tourist services. The green tourism concept would be highly appealing to tourism enterprises and operators owing to increasing governmental pressure to improve environmental performance by adopting effective and tangible environmental management techniques. Green to...

  15. Best practices to optimize intraoperative photography.

    Science.gov (United States)

    Gaujoux, Sébastien; Ceribelli, Cecilia; Goudard, Geoffrey; Khayat, Antoine; Leconte, Mahaut; Massault, Pierre-Philippe; Balagué, Julie; Dousset, Bertrand

    2016-04-01

    Intraoperative photography is used extensively for communication, research, or teaching. The objective of the present work was to define, using a standardized methodology and literature review, the best technical conditions for intraoperative photography. Using either a smartphone camera, a bridge camera, or a single-lens reflex (SLR) camera, photographs were taken under various standard conditions by a professional photographer. All images were independently assessed blinded to technical conditions to define the best shooting conditions and methods. For better photographs, an SLR camera with manual settings should be used. Photographs should be centered and taken vertically and orthogonal to the surgical field with a linear scale to avoid error in perspective. The shooting distance should be about 75 cm using an 80-100-mm focal lens. Flash should be avoided and scialytic low-powered light should be used without focus. The operative field should be clean, wet surfaces should be avoided, and metal instruments should be hidden to avoid reflections. For SLR camera, International Organization for Standardization speed should be as low as possible, autofocus area selection mode should be on single point AF, shutter speed should be above 1/100 second, and aperture should be as narrow as possible, above f/8. For smartphone, use high dynamic range setting if available, use of flash, digital filter, effect apps, and digital zoom is not recommended. If a few basic technical rules are known and applied, high-quality photographs can be taken by amateur photographers and fit the standards accepted in clinical practice, academic communication, and publications. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Intraoperative delineation of brain tumors with special attention of photodynamic diagnosis

    International Nuclear Information System (INIS)

    Hofmann, G.M.

    2001-07-01

    This dissertation gives an overview of the intraoperative techniques of detection of malignant gliomas with special attention of photodynamic diagnosis. The exact identification of infiltrating parts of the malignoma allows the neurosurgeon to perform a resection as complete as possible with sparing eloquent areas. The quality of the m-THPC-induced fluorescence and the influence of the fluorescence-guided resection on the extent of resection are evaluated by histology and on early postoperative MR-imagings. 22 patients suffering from malignant brain tumors receive m-THPC (Foscan: 0,15 mg/kg KG) intravenously four days before operation. After excitation with violet-blue light (370 to 440 nm) tumor-associated red fluorescence is observed either by the naked eye, either by a standard CCD camera and verified by analysis of fluorescence spectra. The surgeon removes fluorescing tissue whenever it is considered safely possible. 138 biopsis are taken of fluorescing and non fluorescing areas in order to correlate them with history. Furthermore the presence of residual enhancement on early postoperative MR-imaging and its congruence in localization with the intraoperative fluorescence are studied. Histological analysis demonstrate 87,9 % sensitivity and 95,7 % specificity for predicting the presence of malignant tissue from visible m-THPC-fluorescence. In 75 % further fluorescence-guided resection is performed. The percentage of postoperative MR-Imagings without residual enhancement after application of PDD rises distinctly. A sensitivity of 100 % and a specificity of 84,6 % are evaluated in the correlation between the presence of m-THPC-fluorescence after resection and the presence of residual enhancement on postoperative MRI. The anatomical localization of the residual tumor on imaging corresponds with the localization of the intraoperative residual fluorescence in all cases. m-THPC-guided resection is a safe and selective method to detect intraoperatively infiltrating

  17. Intraoperative Inducibility of Atrial Fibrillation Does Not Predict Early Postoperative Atrial Fibrillation.

    Science.gov (United States)

    Lanters, Eva A H; Teuwen, Christophe P; Yaksh, Ameeta; Kik, Charles; van der Does, Lisette J M E; Mouws, Elisabeth M J P; Knops, Paul; van Groningen, Nicole J; Hokken, Thijmen; Bogers, Ad J J C; de Groot, Natasja M S

    2018-03-10

    Early postoperative atrial fibrillation (EPoAF) is associated with thromboembolic events, prolonged hospitalization, and development of late PoAF (LPoAF). It is, however, unknown if EPoAF can be predicted by intraoperative AF inducibility. The aims of this study are therefore to explore (1) the value of intraoperative inducibility of AF for development of both EPoAF and LPoAF and (2) the predictive value of de novo EPoAF for recurrence of LPoAF. Patients (N=496, 75% male) undergoing cardiothoracic surgery for coronary and/or valvular heart disease were included. AF induction was attempted by atrial pacing, before extracorporeal circulation. All patients were on continuous rhythm monitoring until discharge to detect EPoAF. During a follow-up period of 2 years, LPoAF was detected by ECGs and Holter recordings. Sustained AF was inducible in 56% of patients. There was no difference in patients with or without AF before surgery ( P =0.159), or between different types of surgery ( P =0.687). In patients without a history of AF, incidence of EPoAF and LPoAF was 37% and 2%, respectively. EPoAF recurred in 58% patients with preoperative AF, 53% developed LPoAF. There were no correlations between intraoperative inducibility and EPoAF or LPoAF ( P >0.05). EPoAF was not correlated with LPoAF in patients without a history of AF ( P =0.116), in contrast to patients with AF before surgery ( P <0.001). Intraoperative AF inducibility does not predict development of either EPoAF or LPoAF. In patients with AF before surgery, EPoAF is correlated with LPoAF recurrences. This correlation is absent in patients without AF before surgery. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  18. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    OpenAIRE

    Zhang, Bing; Li, Ni; Kang, Jie; He, Yi; Chen, Xiao-Ming

    2017-01-01

    Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO) and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography) and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherenc...

  19. [Intraoperative choledochoscopy usefulness in the treatment of difficult biliary stones].

    Science.gov (United States)

    Cuendis-Velázquez, A; Rojano-Rodríguez, M E; Morales-Chávez, C E; González Angulo-Rocha, A; Fernández-Castro, E; Aguirre-Olmedo, I; Torres-Ruiz, M F; Orellana-Parra, J C; Cárdenas-Lailson, L E

    2014-01-01

    Choledocholithiasis presents in 5-10% of the patients with biliary lithiasis. Numerous treatment algorithms have been considered for this disease, however, up to 10% of these therapeutic procedures may fail. Intraoperative choledochoscopy has become a useful tool in the treatment of patients with difficult-to-manage choledocholithiasis. To determine the usefulness of intraoperative choledochoscopy in the laparoendoscopic treatment of difficult stones that was carried out in our service. A cross-sectional study was conducted. The case records were reviewed of the patients that underwent intraoperative choledochoscopy during biliary tree exploration plus laparoscopic choledochoduodenal anastomosis within the time frame of March 1, 2011 and May 31, 2012, at the Hospital General Dr. Manuel Gea González. Transabdominal choledochoscopies were performed with active stone extraction when necessary, followed by peroral choledochoscopies through the recently formed bilioenteric anastomosis. The data were analyzed with descriptive statistics and measures of central tendency. The mean age was 71 years, 57% of the patients were women, and the ASA III score predominated. Active extraction of stones with 7 to 35mm diameters was carried out in 4 of the cases and the absence of stones in the biliary tract was corroborated in all the patients. The mean surgery duration was 18 minutes (range: 4 to 45min). Choledochoscopy is a safe and effective minimally invasive procedure for the definitive treatment of difficult stones. Copyright © 2013 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  20. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    International Nuclear Information System (INIS)

    Adams, S.; Baum, R.P.

    2000-01-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ( 111 In-DTPA-D-Phe 1 )-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands

  1. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. [Johann Wolfgang Goethe Univ., Frankfurt/Main (Germany). Medical Center, Dept. of Nuclear Medicine; Baum, R.P. [Zentralklinik Bad Berka GmbH, Bad Berka (Germany). Clinic of Nuclear Medicine/PET Center

    2000-03-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ({sup 111}In-DTPA-D-Phe{sup 1})-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands.

  2. Microdebrider tonsillectomy associated with more intraoperative blood loss than electrocautery.

    Science.gov (United States)

    Stansifer, Kyle J; Szramowski, Molly G; Barazsu, Lindsay; Buchinsky, Farrel J

    2012-10-01

    To describe and compare the intraoperative blood loss in children who underwent tonsillectomy and/or adenoidectomy during a transition from using electrocautery to a microdebrider. Retrospective case series of a single pediatric otolaryngologist at an urban general hospital. Patients aged 2-20 years who had tonsillectomy, adenoidectomy, or adenotonsillectomy over a 12 month period were included. Tonsillectomy was performed by microdebrider or electrocautery and adenoidectomy was performed by microdebrider, curette, or suction electrocautery. Total intraoperative blood loss was measured and compared between surgical techniques. Of the 148 patients, 109 had tonsillectomy with or without adenoidectomy and 39 had adenoidectomy alone. The mean blood loss was 47 ml or 1.8 ± 1.6 ml/kg and the maximum blood loss was 11 ml/kg. Adenoid curette and adenoid microdebrider yielded similar blood loss but were associated with more bleeding than suction electrocautery (Pelectrocautery tonsillectomy (mean of 2.6 ± 2.2 ml/kg versus 1.2 ± 1.2 ml/kg, P=0.0002). Eighteen percent of adenotonsillectomy patients lost greater than 5% of calculated circulating blood volume (95% CI, 9.8-26). Linear regression models did not show an association between the amount of blood loss and patient age, clinical indication, or the surgeon's experience with the microdebrider (P>0.05). Microdebrider tonsillectomy is associated with more intraoperative bleeding than electrocautery tonsillectomy. Approximately twice as much blood was lost with the microdebrider, but the absolute increase was insignificant from a hemodynamic perspective. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Intraoperative radiation therapy for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Matsutani, Masao; Tanaka, Yoshiaki; Matsuda, Tadayoshi

    1986-01-01

    Intraoperative radiation therapy (IOR) is quite applicable for radioresistant malignant gliomas, because of precise demarcations of the treatment volume under direct vision, minimum damage to surrounding normal tissues, and a high target absorbed dose of 1500 to 2000 rad. Fifteen patients with glioblatoma were treated with IOR, and the 2-year survival rate was 61.1 %. The result apparently indicate that areas adjacent to the margin of almost complete removal should be irradated with a sufficient dose to sterilize the remaining malignant remnants, and IOR is one of the logical treatment modalities for local control of malignant gliomas. (author)

  4. Intraoperative HDR implant boost for breast cancer (preliminary results)

    International Nuclear Information System (INIS)

    Rodriguez, I.; Torre, M. de la; Gonzalez, E.; Bourel, V.

    1996-01-01

    Introduction: In spite of the fact that it is been discussed whether or not a boost is necessary for all conservative treated breast cancer patients, it is a generalized radiotherapy practice. Since september 1993 we developed a breast conservative protocol for early stage breast cancer (T1-T2) with intraoperative HDR implant boost. Side effects, cosmetic results and recurrence rates are reviewed. Method and Material: From September 1993 we treated 55 patients with intraoperative HDR implant boost to the lumpectomy site for clinical T1 or T2 invasive breast cancer, followed by external megavoltage radiotherapy to the entire breast. We used the Nucletron microselectron HDR remote afterloading system with flexible implant tubes. The geometric distribution of the tubes was performed according to the 'Paris' configuration. Each implant was evaluated by calculating the dose-volume natural histograms. The HDR fractionation schedule consists of three fractions of 4.5Gy each given at least 48 hs apart, and starting between 48-72hs from surgical procedure. The external radiotherapy to the entire breast started one week after the completion of brachytherapy, using conventional fractionation of 5 fractions per week, 1,8Gy per fraction up to 45-50Gy. Results: So far there is not any local recurrence, but medium follow up is only 18 months. We did not observe any acute damage and the cosmetic outcome was 60% excellent, 30% good and 10% acceptable. Two patients developed localized fibrosis, in both the implant involved the submamary fold. Conclusion: The intraoperative implant is the most accurate way to localize the lumpectomy site, to define the target volume, decrease the total treatment time and avoid a second anesthetic procedure without delaying the inpatient time or the initial wound healing process

  5. Alpha antagonists and intraoperative floppy iris syndrome: A spectrum

    Directory of Open Access Journals (Sweden)

    Sharif A Issa

    2008-07-01

    Full Text Available Sharif A Issa, Omar H Hadid, Oliver Baylis, Margaret DayanDepartment of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UKBackground: To determine occurrence of features of intraoperative floppy iris syndrome (IFIS during cataract surgery in patients taking systemic alpha-antagonists (AA.Methods: We prospectively studied patients on AA and who underwent phacoemulsification. The following were recorded: pupil diameter preoperatively, iris flaccidity, iris prolapse and peroperative miosis.Results: We studied 40 eyes of 31 subjects. Mean age was 78 years. Overall, 14 eyes (13 patients showed signs of IFIS: 9/13 (69% eyes of patients on tamsulosin, 1/18 (6% eyes in the doxazosin group, 2/2 prazosin patients, 1/4 eyes in the indoramin group, and 1/2 eyes in two patients on a combination of doxazosin and tamsulosin. Most cases (92% had only one or two signs of IFIS. Bilateral cataract surgery was undertaken in 9 patients but only one patient (on tamsulosin had features of IFIS in both eyes, while 4 patients (2 on tamsulosin and 2 on other AA showed signs of IFIS in one eye only, and 4 patients did not show IFIS in either eye.Conclusion: Most AA were associated with IFIS, but it tends to present as a spectrum of signs rather than full triad originally described. Tamsulosin was most likely to be associated with IFIS; however, its intake does not necessarily mean that IFIS will occur. For patients on AA, the behavior of the iris intraoperatively in one eye is a poor predictor of the other eye. Surgeons should anticipate the occurrence of IFIS in any patient on AA.Keywords: alpha blocker, alpha antagonist, cataract surgery, intraoperative floppy iris syndrome, tamsulosin.

  6. Intraoperative discomfort associated with the use of a rotary or reciprocating system: a prospective randomized clinical

    Directory of Open Access Journals (Sweden)

    Aline Cristine Gomes

    2017-05-01

    Full Text Available Objectives The aim of this randomized, controlled, prospective clinical study was to evaluate patients' intraoperative discomfort during root canal preparations in which either multi-file rotary (Mtwo or single-file reciprocating (Reciproc systems were used. Materials and Methods Fifty-five adult patients, aged between 25 and 69 years old, with irreversible pulpitis or pulp necrosis participated in this study. Either the mesiobuccal or the distobuccal canals for maxillary molars and either the mesiobuccal or the mesiolingual canals for mandibular molars were randomly chosen to be instrumented with Mtwo multi-file rotary or Reciproc single-file reciprocating systems. Immediately after each canal instrumentation under anesthesia, patient discomfort was assessed using a 1 - 10 visual analog scale (VAS, ranging from ‘least possible discomfort’ (1 to ‘greatest possible discomfort’ (10. The Wilcoxon signed-rank test was used to determine significant differences at p< 0.05. Results Little intraoperative discomfort was found in all cases. No statistically significant differences in intraoperative discomfort between the 2 systems were found (p = 0.660. Conclusions Root canal preparation with multi-file rotary or single-file reciprocating systems had similar and minimal effects on patients' intraoperative discomfort.

  7. A Case Series of Rapid Prototyping and Intraoperative Imaging in Orbital Reconstruction

    Science.gov (United States)

    Lim, Christopher G.T.; Campbell, Duncan I.; Cook, Nicholas; Erasmus, Jason

    2014-01-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery. PMID:26000080

  8. Conscious sedation for awake craniotomy in intraoperative magnetic resonance imaging operating theater

    Science.gov (United States)

    Takrouri, Mohamad Said Maani; Shubbak, Firas A.; Al Hajjaj, Aisha; Maestro, Rolando F. Del; Soualmi, Lahbib; Alkhodair, Mashael H.; Alduraiby, Abrar M.; Ghanem, Najeeb

    2010-01-01

    This case report describes the first case in intraoperative magnetic resonance imaging operating theater (iMRI OT) (BrainSuite®) of awake craniotomy for frontal lobe glioma excision in a 24-year-old man undergoing eloquent cortex language mapping intraoperatively. As he was very motivated to take pictures of him while being operated upon, the authors adapted conscious sedation technique with variable depth according to Ramsey's scale, in order to revert to awake state to perform the intended neurosurgical procedure. The patient tolerated the situation satisfactorily and was cooperative till the finish, without any event. We elicit in this report the special environment of iMRI OT for lengthy operation in pinned fixed patient having craniotomy. PMID:25885085

  9. Rapid intraoperative tissue expansion with Foley catheter in a challenging cripple Hypospadias

    Directory of Open Access Journals (Sweden)

    Murat Cakmak

    2015-06-01

    Full Text Available ABSTRACTFailed hypospadiass cases may result in hypovascular, scarred penis with residual penile chordee and leave the patient with minimal residual skin for penile resurfacing and urethroplasty. Local tissue expansion has become a good alternative to provide skin for penis by using expanders however they require long periods of time for expansion. Besides, rapid tissue expansion was also described in different tissues. We used rapid intraoperative expansion technique by using a Foley catheter in a failed hypospadias case who had minimal residual skin secondary to infection and we concluded that rapid intraoperative tissue expansion with Foley catheter is an effective, feasible reconstructive method for easy dissection and penile resurfacing in failed hypospadiass cases.

  10. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction.

    Science.gov (United States)

    Lim, Christopher G T; Campbell, Duncan I; Cook, Nicholas; Erasmus, Jason

    2015-06-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery.

  11. Green roofs and the LEED green building rating system

    Energy Technology Data Exchange (ETDEWEB)

    Kula, R. [Sustainable Solutions Inc., Wagoner, OK (United States)

    2005-07-01

    The sustainable building industry is becoming increasingly aware of the host of public and private benefits that green roofs can provide in built environments. In dense urban environments, green roofs function to reduce stormwater runoff, urban heat island effects, and particulate matter (PM) pollution. The emerging green roof industry is now poised to support the efforts of green building networks in North America. This paper discussed the general benefits of green roofs, and their recognition within the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. A case study of Mountain Equipment Co-op's Winnipeg site was presented. The building's green roof was directly responsible for earning 5 credits and contributing to the achievement of an additional 2 credits under the LEEDS certification process. Credits were earned for reduced site disturbance; landscape design to reduce heat islands; and water efficiency. The green roof at the site provided the vast majority of the building's cooling needs through an evaporative cooling trough. A photovoltaic pump was used to feed the building's irrigation system, as well as to pump ground water through cooling valances. It was concluded that the rise of sustainable building practices and the LEED Green Building Rating System will revolutionize the way new buildings are constructed.

  12. Non-radiographic intraoperative fluorescent cholangiography is feasible

    DEFF Research Database (Denmark)

    Larsen, Søren Schytt; Schulze, Svend; Bisgaard, Thue

    2014-01-01

    INTRODUCTION: Intraoperative fluorescent cholangiography (IFC) with concomitant fluorescent angiography was recently developed for non-invasive identification of the anatomy during laparoscopic cholecystectomy. The objective of this study was to assess the time required for routine-use of IFC...... hepatic duct was identified by IFC in all patients. In 29 of the 35 patients (83%; 95% confidence interval: 71-96%), the cystic artery was visualised by fluorescent angiography. No adverse effects or complications were recorded. CONCLUSION: Routine-use of IFC with fluorescent angiography during...

  13. Green Consumerism : an Eco-Friendly Behaviour Form Through The Green Product Consumption and Green Marketing

    OpenAIRE

    Handayani, Wiwik

    2017-01-01

    This research is referred to analyse the influence of consumer attitude of green product towards purchase intention. The consumer attitude of green product is a psychological tendencies that is expressed by evaluating a certain entity with some advantage or disadvantage considerations. The problem of this research is the low of cunsumer awareness to consume green product, because the lack to comprehend the importance of green product usage for health and eco-friendly. The purpose of this rese...

  14. Green power programs in Canada : 2003 : overview of Government green power policies, utility green power implementation initiatives, green power and certificate marketing programs, and their benefits

    International Nuclear Information System (INIS)

    Whitmore, J.; Bramley, M.; Holmes, R.

    2004-09-01

    Green power is defined as electricity produced from renewable sources, and whose production has low adverse impacts on the environment, human health and communities. Green power has near-zero greenhouse gas (GHG) emissions and includes sources such as wind, hydro, and solar power. It offers several environmental benefits, as well as the enhancement of energy security, regional development, economic diversification and the creation of skilled jobs. There are four categories of programs related to green power development in Canada: government green power policies, utility green power development programs, green power marketing initiatives, and green power certificate marketing initiatives. Most of the activities in Canada associated with these four categories in 2003 were discussed in this report. However, difficulties with quantification prevented the inclusion of some green power activities such as (1) the generation of green power not certified or identified by the generator as green power, (2) industry or residential self-generation, (3) net metering, and (4) small government programs. Green power generation facilities in 2003 totaled 775 MW of capacity compared to 539 MW in 2002. Hydro capacity represented 41 per cent, followed by wind capacity at 40 per cent and wood waste at 17 per cent. Most of the green power generation facilities in 2003 were located in Alberta, followed by British Columbia, Ontario and Quebec. 230 refs., 8 tabs., 1 fig

  15. Validation of model-based brain shift correction in neurosurgery via intraoperative magnetic resonance imaging: preliminary results

    Science.gov (United States)

    Luo, Ma; Frisken, Sarah F.; Weis, Jared A.; Clements, Logan W.; Unadkat, Prashin; Thompson, Reid C.; Golby, Alexandra J.; Miga, Michael I.

    2017-03-01

    The quality of brain tumor resection surgery is dependent on the spatial agreement between preoperative image and intraoperative anatomy. However, brain shift compromises the aforementioned alignment. Currently, the clinical standard to monitor brain shift is intraoperative magnetic resonance (iMR). While iMR provides better understanding of brain shift, its cost and encumbrance is a consideration for medical centers. Hence, we are developing a model-based method that can be a complementary technology to address brain shift in standard resections, with resource-intensive cases as referrals for iMR facilities. Our strategy constructs a deformation `atlas' containing potential deformation solutions derived from a biomechanical model that account for variables such as cerebrospinal fluid drainage and mannitol effects. Volumetric deformation is estimated with an inverse approach that determines the optimal combinatory `atlas' solution fit to best match measured surface deformation. Accordingly, preoperative image is updated based on the computed deformation field. This study is the latest development to validate our methodology with iMR. Briefly, preoperative and intraoperative MR images of 2 patients were acquired. Homologous surface points were selected on preoperative and intraoperative scans as measurement of surface deformation and used to drive the inverse problem. To assess the model accuracy, subsurface shift of targets between preoperative and intraoperative states was measured and compared to model prediction. Considering subsurface shift above 3 mm, the proposed strategy provides an average shift correction of 59% across 2 cases. While further improvements in both the model and ability to validate with iMR are desired, the results reported are encouraging.

  16. Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application

    Science.gov (United States)

    Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran

    2015-01-01

    Introduction : Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced “gold-standard” for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. Methods : This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system’s measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Results : Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. Discussion : This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures. PMID:26401167

  17. Utility of intraoperative frozen sections in surgical decision making for acute invasive fungal rhinosinusitis.

    Science.gov (United States)

    Papagiannopoulos, Peter; Lin, Diana Murro; Al-Khudari, Samer; Rajan, Kumar; Reddy, Swathi; Gattuso, Paulo; Tajudeen, Bobby; Batra, Pete S

    2017-05-01

    Acute invasive fungal rhinosinusitis (AIFRS) represents a fulminant, potentially fatal, disease process in immunocompromised patients. The diagnosis often rests on high index of clinical suspicion, with relative paucity of data on the diagnostic and therapeutic implications of intraoperative frozen sections. Retrospective review was performed for 18 cases undergoing endoscopic sinus surgery for AIFRS. Reliability of intraoperative frozen section diagnosis was evaluated for all patients using final pathology as the gold standard. A total of 66 frozen sections were performed. Diagnostic accuracy of frozen sections illustrated sensitivity of 72.7% (95% confidence interval [CI], 0.57 to 0.85), specificity of 100% (95% CI, 0.85 to 1.00), positive predictive value (PPV) of 100% (95% CI, 0.89 to 1.00), and negative predictive value (NPV) of 64.7% (95% CI, 0.46 to 0.80). There was no statistically significant difference in sensitivity of frozen sections in cases of Mucor and Aspergillus at 68.8%% and 76.2%, respectively (p = 0.61). This study represents the largest series assessing the diagnostic accuracy of frozen section analysis in AIFRS. Frozen section analysis is an effective tool for guiding intraoperative decision making in patients with AIFRS with a high PPV. A Low NPV underscores the importance of clinical suspicion and intraoperative decision making based on endoscopic findings when negative frozen section results are encountered. Further, frozen section analysis appears to be equally effective in detecting either Mucor or Aspergillus. © 2017 ARS-AAOA, LLC.

  18. Parotid tumours: clinical and oncologic outcomes after microscope-assisted parotidectomy with intraoperative nerve monitoring.

    Science.gov (United States)

    Carta, F; Chuchueva, N; Gerosa, C; Sionis, S; Caria, R A; Puxeddu, R

    2017-10-01

    Temporary and permanent facial nerve dysfunctions can be observed after parotidectomy for benign and malignant lesions. Intraoperative nerve monitoring is a recognised tool for the preservation of the nerve, while the efficacy of the operative microscope has been rarely stated. The authors report their experience on 198 consecutive parotidectomies performed on 196 patients with the aid of the operative microscope and intraoperative nerve monitoring. 145 parotidectomies were performed for benign lesions and 53 for malignancies. Thirteen patients treated for benign tumours experienced temporary (11 cases) or permanent facial palsy (2 cases, both of House-Brackmann grade II). Ten patients with malignant tumour presented with preoperative facial nerve weakness that did not improve after treatment. Five and 6 patients with malignant lesion without preoperative facial nerve deficit experienced postoperative temporary and permanent weakness respectively (the sacrifice of a branch of the nerve was decided intraoperatively in 2 cases). Long-term facial nerve weakness after parotidectomy for lesions not directly involving or originating from the facial nerve (n = 185) was 2.7%. Patients treated for benign tumours of the extra facial portion of the gland without inflammatory behaviour (n = 91) had 4.4% facial nerve temporary weakness rate and no permanent palsy. The combined use of the operative microscope and intraoperative nerve monitoring seems to guarantee facial nerve preservation during parotidectomy. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  19. Intraoperative real-time planned conformal prostate brachytherapy: Post-implantation dosimetric outcome and clinical implications

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Yamada, Yoshiya; Cohen, Gil'ad N.; Sharma, Neha; Shippy, Alison M.; Fridman, David; Zaider, Marco

    2007-01-01

    Purpose: To report the dosimetric outcome of patients with clinically localized prostate cancer treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. Methods and materials: Five hundred and sixty-two patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning software that incorporates inverse planning optimization was used. Dose-volume constraints for this inverse-planning system included: prostate V100 ≥95%, maximal urethral dose ≤120%, and average rectal dose 3 of the rectum was exposed to the prescription dose, the incidence of late grade 2 toxicity rectal toxicity was 9% compared to 4% for smaller volumes of the rectum exposed to similar doses (p = 0.003). No dosimetric parameter in these patients with tight dose confines for the urethra influenced acute or late urinary toxicity. Conclusion: Real-time intraoperative planning was associated with a 90% consistency of achieving the planned intraoperative dose constraints for target coverage and maintaining planned urethral and rectal constraints in a high percentage of implants. Rectal volumes of ≥2.5 cm 3 exposed to the prescription doses were associated with an increased incidence of grade 2 rectal bleeding. Further enhancements in imaging guidance for optimal seed deposition are needed to guarantee optimal dose distribution for all patients. Whether such improvements lead to further reduction in acute and late morbidities associated with therapy requires further study

  20. Intra-operative warming with a forced-air warmer in preventing hypothermia after tourniquet deflation in elderly patients.

    Science.gov (United States)

    Kim, Y-S; Jeon, Y-S; Lee, J-A; Park, W-K; Koh, H-S; Joo, J-D; In, J-H; Seo, K-W

    2009-01-01

    This randomized, single-blind study aimed to explore the effects of intra-operative warming with a forced-air warmer in the prevention of hypothermia after tourniquet deflation in elderly patients undergoing unilateral total knee replacement arthroplasty under general anaesthesia. Patients were randomized to receive either intra-operative warming using a forced-air warmer with an upper body blanket (warming group; n = 12) or no intra-operative warming (nonwarming group; n = 12). Oesophageal temperature was measured as core body temperature. At 30 min following tourniquet inflation, the core body temperature started to increase in the warming group whereas it continued to drop in the non-warming group. This difference was statistically significant. The final core body temperature after tourniquet deflation was significantly higher in the warming group (mean +/- SD 36.1 +/- 0.2 degrees C) than in the non-warming group (35.4 +/- 0.3 degrees C). Intra-operative forced-air warming increased the core body temperature before tourniquet deflation and prevented subsequent hypothermia in elderly patients under general anaesthesia.