WorldWideScience

Sample records for intraoperative indocyanine green

  1. Indocyanine green for intraoperative localization of ureter.

    Science.gov (United States)

    Siddighi, Sam; Yune, Junchan Joshua; Hardesty, Jeffrey

    2014-10-01

    Intraurethral injection of indocyanine green (ICG; Akorn, Lake Forest, IL) and visualization under near-infrared (NIR) light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Patients were scheduled to undergo robot-assisted laparoscopic sacrocolpopexy. Before the robotic surgery started, the tip of a 6-F ureteral catheter was inserted into the ureteral orifice. Twenty-five milligrams of ICG was dissolved in 10-mL of sterile water and injected through the open catheter. The same procedure was repeated on the opposite side. The ICG reversibly stained the inside lining of the ureter by binding to proteins on urothelial layer. During the course of robotic surgery, the NIR laser on the da Vinci Si surgical robot (Intuitive Surgical, Inc, Sunnyvale, CA) was used to excite ICG molecules, and infrared emission was captured by the da Vinci filtered lens system and electronically converted to green color. Thus, the ureter fluoresced green, which allowed its definitive identification throughout the entire case. In all cases of >10 patients, we were able to visualize bilateral ureters with this technology, even though there was some variation in brightness that depended on the depth of the ureter from the peritoneal surface. For example, in a morbidly obese patient, the ureters were not as bright green. There were no intraoperative or postoperative adverse effects attributable to ICG administration for up to 2 months of observation. In our experience, this novel method of intraurethral ICG injection was helpful to identify the entire course of ureter and allowed a safe approach to tissues that were adjacent to the urinary tract. The advantage of our technique is that it requires the insertion of just the tip of ureteral catheter. Despite our limited cohort of patients, our findings are consistent with previous reports of the excellent safety profile of intravenous and intrabiliary ICG

  2. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Science.gov (United States)

    Miyata, Akinori; Ishizawa, Takeaki; Kamiya, Mako; Shimizu, Atsushi; Kaneko, Junichi; Ijichi, Hideaki; Shibahara, Junji; Fukayama, Masashi; Midorikawa, Yutaka; Urano, Yasuteru; Kokudo, Norihiro

    2014-01-01

    Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous) was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10) under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases), photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical advances are needed

  3. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Directory of Open Access Journals (Sweden)

    Akinori Miyata

    Full Text Available Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10 under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases, photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical

  4. Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion

    DEFF Research Database (Denmark)

    Degett, Thea Helene; Andersen, Helene Schou; Gögenur, Ismail

    2016-01-01

    PURPOSE: Anastomotic leakage following gastrointestinal surgery remains a frequent and serious complication associated with a high morbidity and mortality. Indocyanine green fluorescence angiography (ICG-FA) is a newly developed technique to measure perfusion intraoperatively. The aim of this paper...... included in the review if they assessed anastomotic perfusion intraoperatively with ICG-FA in order to predict anastomotic leakage in humans. RESULTS: Of 790 screened papers 14 studies were included in this review. Ten studies (n = 916) involved patients with colorectal anastomoses and four studies (n...

  5. Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery.

    Science.gov (United States)

    Sound, Sara; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Berber, Eren

    2015-10-27

    Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery. © The Author(s) 2015.

  6. Relevance of intraoperative indocyanine green injection in breast reconstruction using DIEP procedure for abdominal scars.

    Science.gov (United States)

    Louges, M A; Bellaiche, J; Correia, N; Chiriac, S; François, C

    2016-06-01

    The presence of midline sub-umbilical and/or suprapubic scar can sometimes hinder breast reconstruction using deep inferior epigastric perforator (DIEP) procedure. We report the use of indocyanine green injection in a 60-year-old woman in the context of deep inferior epigastric perforator (DIEP) procedure for unilateral breast reconstruction (bilateral breast cancer) with abdominal scar (midline sub-umbilical scar and Pfannenstiel incision scar). This technique underlines the importance of neoangiogenesis mechanisms and helped simplify the surgical gesture initially planned (in order to ensure volume in spite of the scars as a DIEP procedure with double anastomoses was initially planned). This intraoperative vascular imaging technique is a minimally invasive, simple and quick procedure allowing the precise visualization of vascularized territories. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Intraoperative Detection of Superficial Liver Tumors by Fluorescence Imaging Using Indocyanine Green and 5-aminolevulinic Acid.

    Science.gov (United States)

    Kaibori, Masaki; Matsui, Kosuke; Ishizaki, Morihiko; Iida, Hiroya; Okumura, Tadayoshi; Sakaguchi, Tatsuma; Inoue, Kentaro; Ikeura, Tsukasa; Asano, Hiroaki; Kon, Masanori

    2016-04-01

    Indocyanine green (ICG) and the porphyrin precursor 5-aminolevulinic acid (5-ALA) have been approved as fluorescence imaging agents in the clinical setting. This study evaluated the usefulness of fluorescence imaging with both ICG and 5-ALA for intraoperative identification of latent small liver tumors. There were 48 patients who had main tumors within 5 mm of the liver surface. 5-ALA hydrochloride was orally administered to patients 3 h before surgery. ICG had been intravenously injected within 14 days prior to surgery. Intraoperatively, after visual inspection, manual palpation and ultrasonography fluorescence images of the liver surface were obtained with ICG and 5-ALA prior to resection. With ICG, the sensitivity, specificity and accuracy for detecting the preoperatively identified main tumors were 96%, 50% and 94%, respectively. Twelve latent small tumors were newly detected on the liver surface using ICG, five of which proved to be carcinomas. With 5-ALA, the sensitivity, specificity and accuracy for detecting the main tumors were 57%, 100% and 58%, respectively. Five latent small tumors were newly detected using 5-ALA; all were carcinomas. Overall, five new tumors were detected by both ICG and 5-ALA fluorescence imaging; two were hepatocellular carcinomas (HCCs) and three were metastases of colorectal cancer. The sensitivity and specificity of ICG fluorescence imaging for main tumor detection were relatively high and low, respectively, but the opposite was true of 5-ALA imaging. Fluorescence imaging using 5-ALA may provide greater specificity in the detection of surface-invisible malignant liver tumors than using ICG fluorescence imaging alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  8. Intraoperative indocyanine green fluorescent angiography-assisted modified superior gluteal artery perforator flap for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng

    2017-12-01

    Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  9. Intra-Operative Indocyanine Green-Videoangiography (ICG-VA) in ...

    African Journals Online (AJOL)

    Methods: Fifteen consecutive patients with anterior circulation aneurysms who underwent craniotomy and clipping of the aneurysms were included in this study. Intraoperative ICG-VA was performed in all cases after exposure of the aneurysm and the branches in the vicinity of the aneurysm or the parent vessel before ...

  10. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  11. Dynamic indocyanine green angiography measurements

    Science.gov (United States)

    Holmes, Timothy; Invernizzi, Alessandro; Larkin, Sean; Staurenghi, Giovanni

    2012-11-01

    Dynamic indocyanine green imaging uses a scanning laser ophthalmoscope and a fluorescent dye to produce movies of the dye-filling pattern in the retina and choroid of the eye. It is used for evaluating choroidal neovascularization. Movies are examined to identify the anatomy of the pathology for planning treatment and to evaluate progression or response to treatment. The popularity of this approach is affected by the complexity and difficulty in interpreting the movies. Software algorithms were developed to produce images from the movies that are easy to interpret. A mathematical model is formulated of the flow dynamics, and a fitting algorithm is designed that solves for the flow parameters. The images provide information about flow and perfusion, including regions of change between examinations. Imaged measures include the dye fill-time, temporal dispersion, and magnitude of the dye dilution temporal curves associated with image pixels. Cases show how the software can help to identify clinically relevant anatomy such as feeder vessels, drain vessels, capillary networks, and normal choroidal draining vessels. As a potential tool for research into the character of neovascular conditions and treatments, it reveals the flow dynamics and character of the lesion. Future varieties of this methodology may be used for evaluating the success of engineered tissue transplants, surgical flaps, reconstructive surgery, breast surgery, and many other surgical applications where flow, perfusion, and vascularity of tissue are important.

  12. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  13. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  14. A Review of Indocyanine Green Fluorescent Imaging in Surgery

    Directory of Open Access Journals (Sweden)

    Jarmo T. Alander

    2012-01-01

    Full Text Available The purpose of this paper is to give an overview of the recent surgical intraoperational applications of indocyanine green fluorescence imaging methods, the basics of the technology, and instrumentation used. Well over 200 papers describing this technique in clinical setting are reviewed. In addition to the surgical applications, other recent medical applications of ICG are briefly examined.

  15. Retinal pigment epithelial atrophy following indocyanine green dye-assisted surgery for serous macular detachment

    Directory of Open Access Journals (Sweden)

    Hussain Nazimul

    2008-01-01

    Full Text Available To report subretinal migration of indocyanine green dye (ICG and subsequent retinal pigment epithelial (RPE atrophy during macular surgery for serous macular detachment. A 65-year-old woman presented with residual epiretinal membrane and serous detachment of the macula following vitreoretinal surgery for epiretinal membrane. She underwent resurgery with ICG-assisted internal limiting membrane peeling and intraocular tamponade. Intraoperatively a large area of subretinal ICG was seen with subsequent RPE mottling and atrophy of the macula in the area involved during follow-up. This case demonstrates that subretinal migration of ICG is possible and can be toxic to RPE.

  16. DIEP flap customization using Fluobeam® indocyanine green tissue perfusion assessment with large previous abdominal scar

    Directory of Open Access Journals (Sweden)

    Michael A. Fallucco

    2017-06-01

    Full Text Available The Fluobeam® is a portable, near-infrared camera that is held and controlled by the surgeon to visualize tissue perfusion using indocyanine green (ICG fluorescence imaging. This case report describes how data obtained from ICG imaging allows intraoperative customization in a previously surgically scarred abdomen during autologous Deep Inferior Epigastric Artery Perforator (DIEP flap bilateral breast reconstruction. The outcome was successful breast mound recreation without fat necrosis.

  17. Application of indocyanine green video angiography in surgical treatment of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2015-07-01

    Full Text Available Indocyanine green (ICG video angiography has been used for several medical indications in the last decades. It allows a real time evaluation of vascular structures during the surgery. This study describes the surgical results of a senior vascular neurosurgeon. We retrospectively searched our database for all aneurysm cases treated with the aid of intraoperative ICG from 2009 to 2014. A total of 61 aneurysms in 56 patients were surgically clipped using intraoperative ICG. Clip reposition after ICG happened in 2 patients (3.2%. Generally, highly variable clip adjustment rates of 2%–38% following ICG have been reported since the introduction of this imaging technique. The application of ICG in vascular neurosurgery is still an emerging challenge. It is an adjunctive strategy which facilitates aneurismal evaluation and treatment in experienced hands. Nevertheless, a qualified vascular neurosurgeon is still the most important component of a high quality work.

  18. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  19. Application of indocyanine green-fluorescence imaging to full-thickness cholecystectomy.

    Science.gov (United States)

    Morita, Kiyomi; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Shimizu, Atsushi; Yamamoto, Satoshi; Takemura, Nobuyuki; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-05-01

    Fluorescence imaging using indocyanine green (ICG) has recently been applied to laparoscopic surgery to identify cancerous tissues, lymph nodes, and vascular anatomy. Here we report the application of ICG-fluorescence imaging to visualize the boundary between the liver and subserosal tissues of the gallbladder during laparoscopic full-thickness cholecystectomy. A patient with a potentially malignant gallbladder lesion was administered 2.5-mg intravenous ICG just before laparoscopic full-thickness cholecystectomy. Intraoperative fluorescence imaging enabled the real-time delineation of both extrahepatic bile duct anatomy and hepatic parenchyma throughout the procedure, which resulted in complete removal of subserosal tissues between liver and gallbladder. Safe and feasible ICG-fluorescence imaging can be widely applied to laparoscopic hepatobiliary surgery by utilizing a biliary excretion property of ICG. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  20. Indocyanine green enhanced surgery; principle, clinical applications and future research directions

    Directory of Open Access Journals (Sweden)

    Catalin Alius

    2018-05-01

    Full Text Available Over the past decade a new emergent technology has become very popular in all fields of surgery using Indocyanine green and near infrared fluorescent optical systems. This revolutionary approach overlaps conventional and near infrared images to produce highly informative intraoperative images on the anatomy and physiology of various tissues. Near infrared fluorescence is employed for perioperative angiography in vascular mapping, assessment of anastomoses, location of sentinel lymph nodes and delineation of biliary tree anatomy, highlighting tumours and metastatic deposits, improving surgical techniques and for many other uses. A lot of researchers have reported better surgical outcomes and technique innovations facilitated by this novel technology which although in its early stages, it lights up great interest worldwide. This article reviews the principle of the method, the properties of the fluorescent dye, the main clinical applications and discusses future research directions.

  1. Recent advances in near-infrared fluorescence-guided imaging surgery using indocyanine green.

    Science.gov (United States)

    Namikawa, Tsutomu; Sato, Takayuki; Hanazaki, Kazuhiro

    2015-12-01

    Near-infrared (NIR) fluorescence imaging has better tissue penetration, allowing for the effective rejection of excitation light and detection deep inside organs. Indocyanine green (ICG) generates NIR fluorescence after illumination by an NIR ray, enabling real-time intraoperative visualization of superficial lymphatic channels and vessels transcutaneously. The HyperEye Medical System (HEMS) can simultaneously detect NIR rays under room light to provide color imaging, which enables visualization under bright light. Thus, NIR fluorescence imaging using ICG can provide for excellent diagnostic accuracy in detecting sentinel lymph nodes in cancer and microvascular circulation in various ischemic diseases, to assist us with intraoperative decision making. Including HEMS in this system could further improve the sentinel lymph node mapping and intraoperative identification of blood supply in reconstructive organs and ischemic diseases, making it more attractive than conventional imaging. Moreover, the development of new laparoscopic imaging systems equipped with NIR will allow fluorescence-guided surgery in a minimally invasive setting. Future directions, including the conjugation of NIR fluorophores to target specific cancer markers might be realistic technology with diagnostic and therapeutic benefits.

  2. Indocyanine Green Videoangiography in Negative: Spinal Dural Arteriovenous Fistula.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Sanromán Álvarez, Pablo; Pérez de San Román, Laila; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2015-08-01

    Introduction This work reports the first indocyanine green videoangiography (IGV) in negative published with video format support. This technique, so called because its first phase is performed with occlusion of the vessel suspected of being pathologic, is used for the diagnosis of spinal arteriovenous fistula (sDAVF). Case Report The authors present the case of a 68-year-old man with an sDAVF fed by the right T7 segmentary artery. IGV was initially performed with the presumptive fistula feeder occluded for less than 1 minute, which provided both diagnostic and postexclusion control in one procedure. This technique therefore is reversible by not prolonging vascular exclusion times. Discussion IGV in negative is an extremely visual and intuitive procedure that represents an improvement over conventional IGV. Conclusion Studies with larger sample sizes are necessary to determine whether IGV in negative can further reduce the need for postoperative digital subtraction angiography.

  3. [Indocyanine green angiography in "multiple evanescent white dot syndrome" (MEWDS)].

    Science.gov (United States)

    Desarnaulds, A B; Borruat, F X; Herbort, C P; de Courten, C

    1998-05-01

    Multiple evanescent white dot syndrome (MEWDS) is a benign acquired chorioretinal disorder occurring mostly in young adults. Its pathophysiology is unknown. To describe the results of indocyanine green angiography (ICGA) in MEWDS. Four patients with MEWDS were investigated by ICGA. In all cases, ICGA revealed numerous choroidal hypofluorescent lesions that largely outnumbered the lesions visible with either fundoscopy or fluorescein angiography. Three cases showed a blind spot enlargement on perimetry associated with the presence of a large peripapillary hypofluorescent zone on ICGA. Three cases showed macular granularity on fundoscopy correlating with a significant subfoveal hypfluorescent lesion on ICGA. Evolution was always favorable with disappearance of the hypofluorescent choroidal lesions. Our results confirm that MEWDS is primarily a choroidal disorder. The blind spot enlargement and the macular granularity, frequently detected in MEWDS, result from larger peripapillary and subfoveal choroidal lesions.

  4. Application of Indocyanine Green in Flap Surgery: A Systematic Review.

    Science.gov (United States)

    Li, Ke; Zhang, Zheng; Nicoli, Fabio; D'Ambrosia, Christopher; Xi, Wenjing; Lazzeri, Davide; Feng, Shaoqing; Su, Weijie; Li, Hua; Ciudad, Pedro; Tremp, Mathias; Zhang, Yi Xin

    2018-02-01

     The vascularization of the distal portions of transferred tissue represents the most critical factor in the success of reconstructive surgery. In recent years, indocyanine green (ICG) fluorescence imaging techniques have been applied during surgery to evaluate flap perfusion. However, this investigation has found that there is little consensus regarding the standard dose of ICG as well as the pre-operative requirements of ICG allergy testing. The aim of this study is to summarize the applications of ICG to tissue transfers and safe dosing practices and to provide insight to the possible adverse effects of ICG on flap surgery with the goal of helping clinicians apply ICG safely and efficiently to tissue transfer procedures.  A literature search was performed using, Wiley InterScience, and Springer with the key words, 'Flap,' 'indocyanine green,' 'surgery,' and related mesh words for all publications between 2005 and 2015. Title and abstract screening was performed using predefined in- and exclusion criteria.  Seventy-three articles were included. These were classified as "application of ICG in flap surgery" and "the security of applying ICG in flap surgery".  ICG fluorescence imaging preoperatively facilitates the detection of perforators in tissue flaps with thickness <20 mm, aids in the evaluation of flap microcirculation and perfusion, and allows surgeons to select dominant cutaneous nerves while evaluating the quality of vascular anastomoses and locating thromboses. The literature also concluded that potential allergic reactions to ICG should be taken into consideration. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Model and methods to assess hepatic function from indocyanine green fluorescence dynamical measurements of liver tissue.

    Science.gov (United States)

    Audebert, Chloe; Vignon-Clementel, Irene E

    2018-03-30

    The indocyanine green (ICG) clearance, presented as plasma disappearance rate is, presently, a reliable method to estimate the hepatic "function". However, this technique is not instantaneously available and thus cannot been used intra-operatively (during liver surgery). Near-infrared spectroscopy enables to assess hepatic ICG concentration over time in the liver tissue. This article proposes to extract more information from the liver intensity dynamics by interpreting it through a dedicated pharmacokinetics model. In order to account for the different exchanges between the liver tissues, the proposed model includes three compartments for the liver model (sinusoids, hepatocytes and bile canaliculi). The model output dependency to parameters is studied with sensitivity analysis and solving an inverse problem on synthetic data. The estimation of model parameters is then performed with in-vivo measurements in rabbits (El-Desoky et al. 1999). Parameters for different liver states are estimated, and their link with liver function is investigated. A non-linear (Michaelis-Menten type) excretion rate from the hepatocytes to the bile canaliculi was necessary to reproduce the measurements for different liver conditions. In case of bile duct ligation, the model suggests that this rate is reduced, and that the ICG is stored in the hepatocytes. Moreover, the level of ICG remains high in the blood following the ligation of the bile duct. The percentage of retention of indocyanine green in blood, which is a common test for hepatic function estimation, is also investigated with the model. The impact of bile duct ligation and reduced liver inflow on the percentage of ICG retention in blood is studied. The estimation of the pharmacokinetics model parameters may lead to an evaluation of different liver functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy.

    Science.gov (United States)

    Kudo, Hiroki; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Ichida, Akihiko; Shimizu, Atsushi; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-08-01

    Although laparoscopic hepatectomy has increasingly been used to treat cancers in the liver, the accuracy of intraoperative diagnosis may be inferior to that of open surgery because the ability to visualize and palpate the liver surface during laparoscopy is relatively limited. Fluorescence imaging has the potential to provide a simple compensatory diagnostic tool for identification of cancers in the liver during laparoscopic hepatectomy. In 17 patients who were to undergo laparoscopic hepatectomy, 0.5 mg/kg body weight of indocyanine green (ICG) was administered intravenously within the 2 weeks prior to surgery. Intraoperatively, a laparoscopic fluorescence imaging system obtained fluorescence images of its surfaces during mobilization of the liver. In all, 16 hepatocellular carcinomas (HCCs) and 16 liver metastases (LMs) were resected. Of these, laparoscopic ICG fluorescence imaging identified 12 HCCs (75%) and 11 LMs (69%) on the liver surfaces distributed over Couinaud's segments 1-8, including the 17 tumors that had not been identified by visual inspections of normal color images. The 23 tumors that were identified by fluorescence imaging were located closer to the liver surfaces than another nine tumors that were not identified by fluorescence imaging (median [range] depth 1 [0-5] vs. 11 [8-30] mm; p fluorescence imaging enables real-time identification of subcapsular liver cancers, thus facilitating estimation of the required extent of hepatic mobilization and determination of the location of an appropriate hepatic transection line.

  7. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    Science.gov (United States)

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  8. Development of ultrasound-assisted fluorescence imaging of indocyanine green.

    Science.gov (United States)

    Morikawa, Hiroyasu; Toyota, Shin; Wada, Kenji; Uchida-Kobayashi, Sawako; Kawada, Norifumi; Horinaka, Hiromichi

    2017-01-01

    Indocyanine green (ICG) accumulation in hepatocellular carcinoma means tumors can be located by fluorescence. However, because of light scattering, it is difficult to detect ICG fluorescence from outside the body. We propose a new fluorescence imaging method that detects changes in the intensity of ICG fluorescence by ultrasound-induced temperature changes. ICG fluorescence intensity decreases as the temperature rises. Therefore, it should theoretically be possible to detect tissue distribution of ICG using ultrasound to heat tissue, moving the point of ultrasound transmission, and monitoring changes in fluorescence intensity. A new probe was adapted for clinical application. It consisted of excitation light from a laser, fluorescence sensing through a light pipe, and heating by ultrasound. We applied the probe to bovine liver to image the accumulation of ICG. ICG emits fluorescence (820 nm) upon light irradiation (783 nm). With a rise in temperature, the fluorescence intensity of ICG decreased by 0.85 %/°C. The distribution of fluorescent ICG was detected using an ultrasonic warming method in a new integrated probe. Modulating fluorescence by changing the temperature using ultrasound can determine where ICG accumulates at a depth, highlighting its potential as a means to locate hepatocellular carcinoma.

  9. Multiphoton photodegradation of indocyanine green: Solvent protolysis effect

    Energy Technology Data Exchange (ETDEWEB)

    Fuyuki, Masanori, E-mail: mn.fuyuki@kio.ac.jp

    2016-02-15

    The multiphoton photodegradation mechanism of indocyanine green (ICG) was investigated by using femtosecond near-infrared (NIR) pump and probe pulses. In the pump fluence region from 2 mJ/cm{sup 2} to 4 mJ/cm{sup 2}, the photodegradation rate was higher in acetic acid than in ethanol, and the rate was proportional to pump fluence to the 2.3th power in acetic acid and the 3.9th in ethanol. Considering that the degree of auto-protolysis of acetic acid is much higher than that of ethanol, the experimental results indicate that self-ionized solvent molecules played an essential role in the degradation of ICG molecules excited by NIR multiphoton process. - Highlights: • Photodegradation of ICG by femtosecond near-infrared pulses. • Photodegradation rate of ICG was higher in acetic acid than in ethanol. • Photodegradation rate was proportional to pump fluence to 2.3th power in acetic acid. • Photodegradation rate was proportional to pump fluence to 3.9th power in ethanol. • Self-ionized solvent molecules promoted ICG photodegradation in acetic acid.

  10. Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma.

    Science.gov (United States)

    Ishizawa, Takeaki; Masuda, Koichi; Urano, Yasuteru; Kawaguchi, Yoshikuni; Satou, Shouichi; Kaneko, Junichi; Hasegawa, Kiyoshi; Shibahara, Junji; Fukayama, Masashi; Tsuji, Shingo; Midorikawa, Yutaka; Aburatani, Hiroyuki; Kokudo, Norihiro

    2014-02-01

    Although clinical applications of intraoperative fluorescence imaging of liver cancer using indocyanine green (ICG) have begun, the mechanistic background of ICG accumulation in the cancerous tissues remains unclear. In 170 patients with hepatocellular carcinoma cells (HCC), the liver surfaces and resected specimens were intraoperatively examined by using a near-infrared fluorescence imaging system after preoperative administration of ICG (0.5 mg/kg i.v.). Microscopic examinations, gene expression profile analysis, and immunohistochemical staining were performed for HCCs, which showed ICG fluorescence in the cancerous tissues (cancerous-type fluorescence), and HCCs showed fluorescence only in the surrounding non-cancerous liver parenchyma (rim-type fluorescence). ICG fluorescence imaging enabled identification of 273 of 276 (99%) HCCs in the resected specimens. HCCs showed that cancerous-type fluorescence was associated with higher cancer cell differentiation as compared with rim-type HCCs (P Fluorescence microscopy identified the presence of ICG in the canalicular side of the cancer cell cytoplasm, and pseudoglands of the HCCs showed a cancerous-type fluorescence pattern. The ratio of the gene and protein expression levels in the cancerous to non-cancerous tissues for Na(+)/taurocholate cotransporting polypeptide (NTCP) and organic anion-transporting polypeptide 8 (OATP8), which are associated with portal uptake of ICG by hepatocytes that tended to be higher in the HCCs that showed cancerous-type fluorescence than in those that showed rim-type fluorescence. Preserved portal uptake of ICG in differentiated HCC cells by NTCP and OATP8 with concomitant biliary excretion disorders causes accumulation of ICG in the cancerous tissues after preoperative intravenous administration. This enables highly sensitive identification of HCC by intraoperative ICG fluorescence imaging.

  11. Liver volume, portal vein flow, and clearance of indocyanine green and antipyrine in hyperthyroidism before and after antithyroid treatment

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Court-Payen, M

    1999-01-01

    The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment.......The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment....

  12. Effects of indocyanine green videoangiography and electrophysiological monitoring on surgery for intracranial aneurysms

    International Nuclear Information System (INIS)

    Arai, Yoshikazu; Kitai, Ryuhei; Awara, Kosuke

    2011-01-01

    We analyzed the outcome of 62 consecutive patients with unruptured intracranial aneurysm treated by surgical clipping. Thirty-one cases were operated without intraoperative monitoring, 17 cases with indocyanine green videoangiography (ICGA), and 14 cases with electrophysiological monitoring (EPM) in addition to ICGA. Complete obliteration of the aneurysm was confirmed in all 62 cases. Diffusion-weighted imaging of MRI disclosed no ischemic lesions after surgery in any of the cases. Asymptomatic venous infarction was detected by CT study in 2 cases. Cranial nerve palsy occurred in 4 cases but EPM could not detect it. There was no difference among the group without monitoring, the group with ICGA and the group with ICGA and EPM. The mortality and morbidity of all cases was calculated as 0% and 6.5%, respectively. ICGA appeared to be useful in surgery for aneurysms encasing perforators or for repair of problems such as premature rupture. eicosapentaenoic acid (EPA) seemed effective in surgery for anterior choroidal artery aneurysms or aneurysms requiring trapping before clipping. However, monitoring would not have been effective without extensive dissection of aneurysms, suggesting that basic microsurgical techniques are crucial for successful surgery. (author)

  13. Targeted imaging of ovarian cancer cells using viral nanoparticles doped with indocyanine green

    Science.gov (United States)

    Guerrero, Yadir; Bahmani, Baharak; Jung, Bonsu; Vullev, Valentine; Kundra, Vikas; Anvari, Bahman

    2013-03-01

    Our group has constructed a new type of viral nanoparticles (VNPs) from genome-depleted plant infecting brome mosaic virus (BMV) that encapsulates the FDA-approved near infrared (NIR) indocyanine green (ICG)[1]. We refer to these VNPs as optical viral ghosts (OVGs) since the constructs lack the genomic content of wild-type BMV. One of our areas of interest is the application of OVGs for real-time intraoperative NIR fluorescence imaging of small peritoneal ovarian tumor nodules. We target human epidermal growth factor receptor-2 (HER-2) expression in ovarian cancer as a biomarker associated with ovarian cancer, since its over-expression is linked to the disease's progression to death. We functionalize the OVGs with anti-HER-2 monoclonal antibodies using reductive amination methods. We used fluorescence imaging to visualize the SKOV-3 cells (high HER-2 expression) after incubation with free ICG, OVGs, and functionalized OVGs. Our results suggest the possibility of using anti-HER2 conjugated OVGs in conjunction with cytoreductive surgery to detect small tumor nodules (<5cm) which currently are not excised during surgery.

  14. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  15. Antipyrine, oxazepam, and indocyanine green clearance in patients with chronic pancreatitis and healthy subjects

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Larsen, S

    1999-01-01

    Hepatic drug metabolism was examined in patients with chronic pancreatitis and healthy controls by using a cocktail design with three different model compounds: antipyrine to express phase-I oxidation, oxazepam to express phase-II conjugation, and indocyanine green (ICG), a high-clearance compound....

  16. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  17. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  18. Microencapsulation of indocyanine green for potential applications in image-guided drug delivery.

    Science.gov (United States)

    Zhu, Zhiqiang; Si, Ting; Xu, Ronald X

    2015-02-07

    We present a novel process to encapsulate indocyanine green (ICG) in liposomal droplets at high concentration for potential applications in image-guided drug delivery. The microencapsulation process follows two consecutive steps of droplet formation by liquid-driven coaxial flow focusing (LDCFF) and solvent removal by oil phase dewetting. These biocompatible lipid vesicles may have important applications in drug delivery and fluorescence imaging.

  19. Laparoscopic Sentinel Node Mapping in Endometrial Cancer After Hysteroscopic Injection of Indocyanine Green.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-01-01

    To report the detection rate (DR) of sentinel lymph nodes (SLNs) in endometrial cancer (EC) patients after hysteroscopic injection of indocyanine green (ICG) and laparoscopic near-infrared (L-NIR) fluorescence mapping. Prospectively collected data (Canadian Task Force classification II-2). Gynecologic oncology referral center. Consecutive patients with apparent early-stage endometrioid EC scheduled for surgical treatment: total laparoscopic hysterectomy, bilateral salpingo-oophorectomy, SLN mapping. The mapping technique consisted in an intraoperative hysteroscopic peritumoral injection of 5 mg ICG followed by L-NIR fluorescence mapping. Evaluations of the SLN DR and sites of mapping were performed. A total of 57 procedures was performed. Patient mean age was 60 years (range, 28-80) and mean body mass index was 28.2 kg/m 2 (range, 19-43). At least 1 SLN was detected in 89.5% of the whole population (51/57). After the first 16 cases, L-NIR camera technical improvement led to a 95% DR (39/41). The mean number of harvested SLNs was 4.1 (range. 1-8), and in 47% of cases SLNs mapped to aortic nodes (24/51). Bilateral pelvic mapping was found in 74.5% of cases (38/51). Three patients had SLN metastases: 1 in the pelvic area only, 1 both in the pelvic and aortic area, and 1 presented with 2 metastatic aortic SLNs with negative pelvic SLNs. Overall, 2 of 3 node-positive patients (67%) had aortic SLN involvement. No adverse events were reported. Laparoscopic SLN mapping after the hysteroscopic injection of ICG has comparable DRs with both radioactive tracer series and ICG series with cervical injection, overcoming the need for radioactive substances. Hysteroscopic injection leads to a higher mapping in the aortic area compared with cervical injection. Further investigation is warranted on this topic. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  20. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  1. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    DEFF Research Database (Denmark)

    Omar, Ghada Said Mohammed; Wilson, Michael; Nair, Sean P.

    2008-01-01

    Background: The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs). Light of an appropriate wavelength activates the LAAA to produce cytotoxic...... of the bacteria. Conclusion: These findings imply that indocyanine green in combination with light from a nearinfrared laser may be an effective means of eradicating bacteria from wounds and burns....

  2. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy

    OpenAIRE

    KITAGAWA, HIROYUKI; NAMIKAWA, TSUTOMU; IWABU, JUN; HANAZAKI, KAZUHIRO

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric t...

  3. Indocyanine Green Videoangiography for Surgery of a Ruptured Dissecting Aneurysm in the Precommunicating Anterior Cerebral Artery: A Technical Case Report.

    Science.gov (United States)

    Nagai, Yasunori; Goto, Masanori; Toda, Hiroki; Nishida, Namiko; Yoshimoto, Naoya; Iwasaki, Koichi

    2017-08-01

    Indocyanine green videoangiography (ICG-VA) is an important intraoperative adjunct for saccular aneurysm surgery, but its efficacy in surgery for dissecting aneurysms has rarely been reported. The authors describe the usefulness of preclipping ICG-VA in a rare case of a ruptured dissecting aneurysm located at the precommunicating (A1) segment of the anterior cerebral artery. A 52-year-old woman, with no history of connective tissue diseases or vascular disorders, presented with sudden headache and convulsion. The CT scan showed that the patient had subarachnoid hemorrhage. Angiography showed a dissecting aneurysm in the left A1 segment of the anterior cerebral artery. Thus, the patient underwent trapping of the dissecting aneurysm. ICG-VA was used as an intraoperative adjunct before and after clipping. The preclipping ICG-VA showed the heterogeneously bright dissecting aneurysm and branching arteries even in the presence of hematoma. Preclipping ICG-VA may enhance the advantage of direct surgery for dissecting aneurysm by allowing visualization of the extent of the dissected vascular wall and the related branching arteries. ICG-VA can be an indispensable adjunct to minimize the compromise from the surgical treatment for intracranial dissecting aneurysms. Copyright © 2017 by the Congress of Neurological Surgeons

  4. Comparison of indocyanine green clearance with Child's-Pugh score and hepatic histology: a multivariate analysis.

    Science.gov (United States)

    Mukherjee, Sandeep; Rogers, Mary A M; Buniak, Borys

    2006-01-01

    Indocyanine green clearance, measured by percentage disappearance rate, detects alterations in liver function and may be used as a non-invasive determinant of hepatic reserve. The aims of this study were to compare liver histology and Child's-Pugh score with percentage disappearance rate and determine which variables correlated with PDR. Child's-Pugh score, liver function tests, liver biopsies and indocyanine green testing (0.5mg/kg) were performed in 102 consecutive patients with cirrhosis of diverse etiologies. Indocyanine green concentration was determined using spectrophotometric analysis (806nm) and plotted logarithmically with Michaelis-Menten kinetics to calculate the percentage disappearance rate. Liver biopsies were graded using the modified Knodell score to obtain a histological activity index. In bivariable analysis, percentage disappearance rate significantly correlated with Child's-Pugh score, albumin, bilirubin, prothrombin time and histological activity index. Albumin, prothrombin time and histological activity index were independent predictors of percentage disappearance rate in the final model (albumin ptime ptime and histological activity index.

  5. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  6. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy.

    Science.gov (United States)

    Kitagawa, Hiroyuki; Namikawa, Tsutomu; Iwabu, Jun; Hanazaki, Kazuhiro

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric tube. When pulling up the gastric tube through the post-mediastinum route, a root of the right gastroepiploic vein was injured. We subsequently performed superdrainage to avoid congestion of the gastric tube with omental vein and pre-tracheal vein anastomosis at the neck, and confirmed venous flow using the indocyanine green fluorescence method. No postoperative anastomotic leakage was observed, and the patient was discharged 22 days after surgery. Thus, we recommend the indocyanine green fluorescence method in cases involving superdrainage during esophagectomy. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  7. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    Directory of Open Access Journals (Sweden)

    Wilson Michael

    2008-07-01

    Full Text Available Abstract Background The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs. Light of an appropriate wavelength activates the LAAA to produce cytotoxic species which can then cause bacterial cell death via loss of membrane integrity, lipid peroxidation, the inactivation of essential enzymes, and/or exertion of mutagenic effects due to DNA modification. In this study, the effect of the LAAA indocyanine green excited with high or low intensity light (808 nm from a near-infrared laser (NIR on the viability of Staphylococcus aureus, Streptococcus pyogenes and Pseudomonas aeruginosa was investigated. Results All species were susceptible to killing by the LAAA, the bactericidal effect being dependent on both the concentration of indocyanine green and the light dose. Indocyanine green photosensitization using both high (1.37 W cm-2 and low (0.048 W cm-2 intensity NIR laser light was able to achieve reductions of 5.6 log10 (>99.99% and 6.8 log10 (>99.99% in the viable counts of Staph. aureus and Strep. pyogenes (using starting concentrations of 106–107 CFU ml-1. Kills of 99.99% were obtained for P. aeruginosa (initial concentration 108–109 CFU ml-1 photosensitized by the high intensity light (1.37 W cm-2; while a kill of 80% was achieved using low intensity irradiation (0.07 W cm-2. The effects of L-tryptophan (a singlet oxygen scavenger and deuterium oxide (as an enhancer of the life span of singlet oxygen on the survival of Staph. aureus was also studied. L-tryptophan reduced the proportion of Staph. aureus killed; whereas deuterium oxide increased the proportion killed suggesting that singlet oxygen was involved in the killing of the bacteria. Conclusion These findings imply that indocyanine green in combination with light from a near-infrared laser may be an effective means of eradicating bacteria

  8. The Role of Indocyanine Green for Robotic Partial Nephrectomy: Early Results, Limitations and Future Directions

    Directory of Open Access Journals (Sweden)

    Zachary Klaassen

    2014-07-01

    Full Text Available The surgical management of small renal masses has continued to evolve, particularly with the advent of the robotic partial nephrectomy (RPN. Recent studies at high volume institutions utilizing near infrared imaging with indocyanine green (ICG fluorescent dye to delineate renal tumor anatomy has generated interest among robotic surgeons for improving warm ischemia times and positive margin rate for RPN. To date, early studies suggest positive margin rate using ICG is comparable to traditional RPN, however this technology improves visualization of the renal vasculature allowing selective clamping or zero ischemia. The precise combination of fluorescent compound, dose, and optimal tumor anatomy for ICG RPN has yet to be elucidated.

  9. Phototoxic effect of conjugates of plasmon-resonance nanoparticles with indocyanine green dye on Staphylococcus aureus induced by IR laser radiation

    International Nuclear Information System (INIS)

    Tuchina, E S; Tuchin, Valerii V; Khlebtsov, B N; Khlebtsov, Nikolai G

    2011-01-01

    The effect of IR laser radiation (λ = 805 - 808 nm) on the bacteria of the strain Staphylococcus aureus 209 P, incubated in indocyanine green solutions, is studied, as well as that of colloid gold nanoshells, nanocages and their conjugates with indocyanine green. It is found that the S. aureus 209 P cells are equally subjected to the IR laser radiation (λ = 805 nm) after preliminary sensitisation with indocyanine green and gold nanoparticles separately and with conjugates of nanoparticles and indocyanine green. The enhancement of photodynamic and photothermal effects by 5 % is observed after 30 min of laser illumination (λ = 808 nm) of bacteria, treated with conjugates of indocyanine green and nanocages. (optical technologies in biophysics and medicine)

  10. Comparison of indocyanine green fluorescence and parathyroid autofluorescence imaging in the identification of parathyroid glands during thyroidectomy.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-12-01

    Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P0.99]. To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF.

  11. Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    Science.gov (United States)

    Rathmann, P; Chalopin, C; Halama, D; Giri, P; Meixensberger, J; Lindner, D

    2018-03-01

    Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermography (DIRT) is a promising alternative modality that was evaluated by comparison with ICGA. The study was carried out in two parts: (1) investigation of technical conditions for intraoperative use of DIRT for its comparison with ICGA, and (2) visual and quantitative comparison of both modalities in a proof of concept on nine patients. Time-temperature curves in DIRT and time-intensity curves in ICGA for defined regions of interest were analyzed. New perfusion parameters were defined in DIRT and compared with the usual perfusion parameters in ICGA. The visual observation of the image data in DIRT and ICGA showed that operation material, anatomical structures and skin perfusion are represented similarly in both modalities. Although the analysis of the curves and perfusion parameter values showed differences between patients, no complications were observed clinically. These differences were represented in DIRT and ICGA equivalently. DIRT has shown a great potential for intraoperative use, with several advantages over ICGA. The technique is passive, contactless and noninvasive. The practicability of the intraoperative recording of the same operation field section with ICGA and DIRT has been demonstrated. The promising results of this proof of concept provide a basis for a trial with a larger number of patients.

  12. Indocyanine green videoangiography "in negative": definition and usefulness in spinal dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; López González, Antonio; Evangelista Zamora, Rocío; Botella Asunción, Carlos

    2013-05-01

    Indocyanine green videoangiography (IGV) has proven its effectiveness in the field of exovascular neurosurgery, both in the intracranial and spinal compartment, but is necessary to define a systematic process for the performance of the IGV to facilitate its interpretation during the procedure. We have defined and applied the concept of videoangiography "in negative" (INIGV) to spinal dural arteriovenous fistulae (dAVF) for the detection and treatment of arteriovenous shunts, so called because the first phase is performed with the vessel suggestive of being pathological occluded. A Pentero-operating microscope with near-infrared IGV-integrated system (Carl Zeiss Co., Germany) was used. At our institution, 24 patients were treated for a spinal dAVF between 1995 and 2011, only in the last 4 cases, INIGV was performed. We describe the IGV in negative procedure and show the most illustrative cases. In all cases, the fistula occlusion was confirmed by postoperative selective digital subtraction angiography (DSA). INIGV demonstrate its capacity in detecting vessels not actually arterialized that should be respected and avoid some of the main limitations of the conventional IGV. This is a technical description about an Indocyanine green (ICG) videoangiographic procedure modification that is superior to merely performing ICG before and after clipping of a dAVF. The INIGV results are rapid and easy to interpret procedure and provide great advantages to the dAVF treatment. Nevertheless, further studies are needed with a larger sample size to determine if INIGV may reduce the need to perform immediate postoperative DSA.

  13. Lipid nanoparticle vectorization of indocyanine green improves fluorescence imaging for tumor diagnosis and lymph node resection.

    Science.gov (United States)

    Navarro, Fabrice P; Berger, Michel; Guillermet, Stéphanie; Josserand, Véronique; Guyon, Laurent; Neumann, Emmanuelle; Vinet, Françoise; Texier, Isabelle

    2012-10-01

    Fluorescence imaging is opening a new era in image-guided surgery and other medical applications. The only FDA approved contrast agent in the near infrared is IndoCyanine Green (ICG), which despites its low toxicity, displays poor chemical and optical properties for long-term and sensitive imaging applications in human. Lipid nanoparticles are investigated for improving ICG optical properties and in vivo fluorescence imaging sensitivity. 30 nm diameter lipid nanoparticles (LNP) are loaded with ICG. Their characterization and use for tumor and lymph node imaging are described. Nano-formulation benefits dye optical properties (6 times improved brightness) and chemical stability (>6 months at 4 degrees C in aqueous buffer). More importantly, LNP vectorization allows never reported sensitive and prolonged (>1 day) labeling of tumors and lymph nodes. Composed of human-use approved ingredients, this novel ICG nanometric formulation is foreseen to expand rapidly the field of clinical fluorescence imaging applications.

  14. In Vivo Photoacoustic and Fluorescence Cystography Using Clinically Relevant Dual Modal Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Sungjo Park

    2014-10-01

    Full Text Available Conventional X-ray-based cystography uses radio-opaque materials, but this method uses harmful ionizing radiation and is not sensitive. In this study, we demonstrate nonionizing and noninvasive photoacoustic (PA and fluorescence (FL cystography using clinically relevant indocyanine green (ICG in vivo. After transurethral injection of ICG into rats through a catheter, their bladders were photoacoustically and fluorescently visualized. A deeply positioned bladder below the skin surface (i.e., ~1.5–5 mm was clearly visible in the PA and FL image using a laser pulse energy of less than 2 mJ/cm2 (1/15 of the safety limit. Then, the in vivo imaging results were validated through in situ studies. Our results suggest that dual modal cystography can provide a nonionizing and noninvasive imaging tool for bladder mapping.

  15. Near-infrared-fluorescence imaging of lymph nodes by using liposomally formulated indocyanine green derivatives.

    Science.gov (United States)

    Toyota, Taro; Fujito, Hiromichi; Suganami, Akiko; Ouchi, Tomoki; Ooishi, Aki; Aoki, Akira; Onoue, Kazutaka; Muraki, Yutaka; Madono, Tomoyuki; Fujinami, Masanori; Tamura, Yutaka; Hayashi, Hideki

    2014-01-15

    Liposomally formulated indocyanine green (LP-ICG) has drawn much attention as a highly sensitive near-infrared (NIR)-fluorescence probe for tumors or lymph nodes in vivo. We synthesized ICG derivatives tagged with alkyl chains (ICG-Cn), and we examined NIR-fluorescence imaging for lymph nodes in the lower extremities of mice by using liposomally formulated ICG-Cn (LP-ICG-Cn) as well as conventional liposomally formulated ICG (LP-ICG) and ICG. Analysis with a noninvasive preclinical NIR-fluorescence imaging system revealed that LP-ICG-Cn accumulates in only the popliteal lymph node 1h after injection into the footpad, whereas LP-ICG and ICG accumulate in the popliteal lymph node and other organs like the liver. This result indicates that LP-ICG-Cn is a useful NIR-fluorescence probe for noninvasive in vivo bioimaging, especially for the sentinel lymph node. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Photodynamic actions of indocyanine green and trypan blue on human lens epithelial cells in vitro.

    Science.gov (United States)

    Melendez, Robert F; Kumar, Neeru; Maswadi, Saher M; Zaslow, Kenneth; Glickmank, Randolph D

    2005-07-01

    The purpose of this study was to evaluate the toxicity and photodynamic activity of indocyanine green (ICG) and trypan blue (TryB) on cultured human lensepithelial cells (LECs). Experimental study. Lens epithelial cell viability was assessed after treatment with ICG and TryB concentrations ranging from 0.025 to 5.0 mg/ml, and exposure to 806 nm diode laser. At ICG concentrations below 0.5 mg/ml, there was > or =75% cell viability; at higher ICG concentrations there was dose-dependent cytotoxicity in addition to loss of cellular viability due to ICG photosensitization. TryB had little cytotoxicity to the LECs: >80% cells were viable irrespective of the dye concentration or laser treatment. These data indicate that ICG may have application as a photosensitizer in the selective eradication of residual LECs after cataract surgery to reduce the incidence of posterior capsule opacification.

  17. Indocyanine green labeled with 123I for dynamic studies of the hepato-biliary system

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub 1 / 2 / = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of 123 I-ICG (in dogs) will be compared to 131 I-rose bengal and bromosulphalein labeled with iodine-125

  18. In Vitro Efficacy and Mechanistic Role of Indocyanine Green as a Photodynamic Therapy Agent for Human Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.; Gamal-Eldeen, A; Ruppel, M; Smith, R; Tsang, T; Miller, L

    2009-01-01

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway.

  19. Indocyanine green loaded graphene oxide for high-efficient photoacoustic tumor therapy

    Directory of Open Access Journals (Sweden)

    Baoyun Yan

    2016-07-01

    Full Text Available Photoacoustic therapy, using the photoacoustic effect of agents for selectively killing tumor cells, has shown promising for treating tumor. Utilization of high optical absorption probes can help to effectively improve the photoacoustic therapy efficiency. Herein, we report a novel high-absorption photoacoustic probe that is composed of indocyanine green (ICG and graphene oxide (GO, entitled GO-ICG, for photoacoustic therapy. The attached ICG with narrow absorption spectral profile has strong optical absorption in the infrared region. The absorption spectrum of the GO-ICG solution reveals that the GO-ICG particles exhibited a 10-fold higher absorbance at 780nm (its peak absorbance as compared with GO. Importantly, ICG’s fluorescence is quenched by GO via fluorescence resonance energy transfer. As a result, GO-ICG can high-efficiently convert the absorbed light energy to acoustic wave under pulsed laser irradiation. We further demonstrate that GO-ICG can produce stronger photoacoustic wave than the GO and ICG alone. Moreover, we conjugate this contrast agent with integrin αvβ3 mono-clonal antibody to molecularly target the U87-MG human glioblastoma cells for selective tumor cell killing. Finally, our results testify that the photoacoustic therapy efficiency of GO-ICG is higher than the existing photoacoustic therapy agent. Our work demonstrates that GO-ICG is a high-efficiency photoacoustic therapy agent. This novel photoacoustic probe is likely to be an available candidate for tumor therapy.

  20. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  1. Indocyanine green videoangiography "in negative": definition and usefulness in intracranial dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Aparici Robles, Fernando; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2013-09-01

    Indocyanine green videoangiography (IGV) raises important limitations when we use it in vascular pathology, especially in cases with arterialization of the venous system such as arteriovenous malformations and fistulae. Our objective was to provide a simple procedure that overcomes the limitations of conventional IGV. We define IGV in negative (IGV-IN), so-called because, in its first phase, the vessel to analyze is clipped, and we report 3 cases of intracranial dural arteriovenous fistulae treated with this procedure. In 2011, we applied IGV-IN to 3 patients at our center with Borden type III intracranial arteriovenous fistulae. In all 3 cases, IGV-IN enabled both diagnosis and post-dural arteriovenous fistula exclusion control in 1 integrated procedure no longer than 1 minute, requiring only 1 visualization. IGV-IN is an improvement over the conventional IGV method and is able to provide more information in a shorter period of time. It is an intuitive and highly visual procedure, and, more importantly, it is reversible. Studies with larger samples are necessary to determine whether IGV-IN can further reduce the need for postoperative digital subtraction angiography.

  2. Leveraging Engineering of Indocyanine Green-Encapsulated Polymeric Nanocomposites for Biomedical Applications.

    Science.gov (United States)

    Han, Ya-Hui; Kankala, Ranjith Kumar; Wang, Shi-Bin; Chen, Ai-Zheng

    2018-05-24

    In recent times, photo-induced therapeutics have attracted enormous interest from researchers due to such attractive properties as preferential localization, excellent tissue penetration, high therapeutic efficacy, and minimal invasiveness, among others. Numerous photosensitizers have been considered in combination with light to realize significant progress in therapeutics. Along this line, indocyanine green (ICG), a Food and Drug Administration (FDA)-approved near-infrared (NIR, >750 nm) fluorescent dye, has been utilized in various biomedical applications such as drug delivery, imaging, and diagnosis, due to its attractive physicochemical properties, high sensitivity, and better imaging view field. However, ICG still suffers from certain limitations for its utilization as a molecular imaging probe in vivo, such as concentration-dependent aggregation, poor in vitro aqueous stability and photodegradation due to various physicochemical attributes. To overcome these limitations, much research has been dedicated to engineering numerous multifunctional polymeric composites for potential biomedical applications. In this review, we aim to discuss ICG-encapsulated polymeric nanoconstructs, which are of particular interest in various biomedical applications. First, we emphasize some attractive properties of ICG (including physicochemical characteristics, optical properties, metabolic features, and other aspects) and some of its current limitations. Next, we aim to provide a comprehensive overview highlighting recent reports on various polymeric nanoparticles that carry ICG for light-induced therapeutics with a set of examples. Finally, we summarize with perspectives highlighting the significant outcome, and current challenges of these nanocomposites.

  3. [Place of indocyanine green coupled with fluorescence imaging in research of breast cancer sentinel node].

    Science.gov (United States)

    Vermersch, Charlotte; Raia Barjat, Tiphaine; Perrot, Marianne; Lima, Suzanne; Chauleur, Céline

    2016-04-01

    The sentinel node has a fundamental role in the management of early breast cancer. Currently, the double detection of blue and radioisotope is recommended. But in common practice, many centers use a single method. However, with a single detection, the risk of false negatives and the identification failure rate increase to a significant extent and the number of sentinel lymph node detected and removed is not enough. Furthermore, the tracers used until now show inconveniences. The purpose of this work is to present a new method of detection, using the green of indocyanine coupled with fluorescence imaging, and to compare it with the already existing methods. The method combined by fluorescence and isotopic is reliable, sure, of fast learning and could constitute a good strategy of detection. The major interest is to obtain a satisfactory number of sentinel nodes. The profit could be even more important for overweight patients. The fluorescence used alone is at the moment not possible. Wide ranging studies are necessary. The FLUOTECH, randomized study of 100 patients, comparing the isotopic method of double isotope technique and fluorescence, is underway to confirm these data. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  4. In vitro efficiency and mechanistic role of indocyanine green as photodynamic therapy agent for human melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.M.; Miller, L.; Gamal-Eldeen, A. M.; Ruppel, M. E.; Smith, R. J.; Tsang, T.; Miller, L. M.

    2009-05-02

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800 nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway. Human skin melanoma cells (Sk-Mel-28) were incubated with ICG and exposed to a low power Ti:Sapphire laser. Synchrotron-assisted Fourier transform infrared microspectroscopy and hierarchical cluster analysis were used to assess the cell damage and changes in lipid, protein, and nucleic acids. The cell death pathway was determined by analysis of cell viability and apoptosis and necrosis markers. In the cell death pathway, {sup 1}O{sub 2} generation evoked rapid multiple consequences that trigger apoptosis after laser exposure for only 15min including the release of cytochrome c, the activation of total caspases, caspase-3, and caspase-9, the inhibition of NF-{Kappa}B P65, and the enhancement of DNA fragmentation, and histone acetylation. ICG/PDT can efficiently and rapidly induce apoptosis in human melanoma cells and it can be considered as a new therapeutic approach for topical treatment of melanoma.

  5. Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation.

    Science.gov (United States)

    Bruegger, Lukas; Studer, Peter; Schmid, Stefan W; Pestel, Gunther; Reichen, Juerg; Seiler, Christian; Candinas, Daniel; Inderbitzin, Daniel

    2008-01-01

    Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI]=0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into account.

  6. Toxicity profiles of subretinal indocyanine green, Brilliant Blue G, and triamcinolone acetonide: a comparative study

    DEFF Research Database (Denmark)

    Ejstrup, Rasmus; Dornonville de la Cour, Morten; Heegaard, Steffen

    2012-01-01

    BACKGROUND: This study introduces a novel porcine model to examine the histopathological and electrophysiological consequences of retinotoxicity exerted by dyes commonly used for internal limiting membrane (ILM) staining. METHODS: Indocyanine green (ICG) 0.5 mg/ml, Brilliant Blue G (BBG) 0.25 mg....../ml and triamcinolone acetonide (TA) 13 mg/ml was injected subretinally in 12 vitrectomized pig eyes. At 6 weeks, retinas were examined by multifocal electroretinography (mfERG), ophthalmoscopy, fluorescein angiograpy, histopathology, and apoptosis assay. RESULTS: mfERG responses were significantly lower in ICG......-injected eyes than in healthy fellow eyes (p¿=¿0.039). The ratio between injected eyes and healthy fellow eyes was lower in the ICG group than in the BBG (p¿=¿0.009) and TA group (p¿=¿0.025). No difference between BBG and TA existed. All retinas were reattached, and fluorescein angiographies showed a window...

  7. Symmetricity analysis of time to peak parameter of indocyanine green dynamics

    Science.gov (United States)

    An, Yuri; Lee, Jungsul; Choi, Chulhee

    2013-03-01

    We have previously discovered that near-infrared optical imaging of indocyanine green (ICG) signal and analyzing its dynamics can be applied for measurement of blood perfusion rate and detection of Raynaud's phenomenon (RP). Especially, RP is closely associated with abnormal vasomotor responses and can progress to tissue necrosis due to excessively sustained vasoconstriction. Therefore, early detecting of RP is one of important implication to prevent tissue damage from peripheral vascular disorders. In the present study, we propose new analysis and scoring method of symmetricity of Tmax value of left and right extremities. Moreover, this symmetricity analysis can give further information about microvascular insufficiency. For validation of the proposed method, we tested whether the segmental and paired analysis of Tmax value (time-to-peak) of ICG dynamics can be used for sensitive diagnosis of microvascular abnormalities which cannot be detected by conventional methods. From the near-infrared images of diabetes mellitus patients with vascular complications, the trend of asymmetry in Tmax value was observed. We assumed that decreasing local blood perfusion by autonomic nerve dysfunction causes the asymmetric Tmax value of right and left feet. These results collectively indicate that the proposed method can be used as a useful diagnostic tool for RP or other microvascular disorders.

  8. Development and validation of a custom made indocyanine green fluorescence lymphatic vessel imager

    Science.gov (United States)

    Pallotta, Olivia J.; van Zanten, Malou; McEwen, Mark; Burrow, Lynne; Beesley, Jack; Piller, Neil

    2015-06-01

    Lymphoedema is a chronic progressive condition often producing significant morbidity. An in-depth understanding of an individual's lymphatic architecture is valuable both in the understanding of underlying pathology and for targeting and tailoring treatment. Severe lower limb injuries resulting in extensive loss of soft tissue require transposition of a flap consisting of muscle and/or soft tissue to close the defect. These patients are at risk of lymphoedema and little is known about lymphatic regeneration within the flap. Indocyanine green (ICG), a water-soluble dye, has proven useful for the imaging of lymphatic vessels. When injected into superficial tissues it binds to plasma proteins in lymph. By exposing the dye to specific wavelengths of light, ICG fluoresces with near-infrared light. Skin is relatively transparent to ICG fluorescence, enabling the visualization and characterization of superficial lymphatic vessels. An ICG fluorescence lymphatic vessel imager was manufactured to excite ICG and visualize real-time fluorescence as it travels through the lymphatic vessels. Animal studies showed successful ICG excitation and detection using this imager. Clinically, the imager has assisted researchers to visualize otherwise hidden superficial lymphatic pathways in patients postflap surgery. Preliminary results suggest superficial lymphatic vessels do not redevelop in muscle flaps.

  9. Thermal and infrared-diode laser effects on indocyanine-green-treated corneal collagen

    Science.gov (United States)

    Timberlake, George T.; Patmore, Ann; Shallal, Assaad; McHugh, Dominic; Marshall, John

    1993-07-01

    It has been suggested that laser welds of collagenous tissues form by interdigitation and chemical bonding of thermally 'unraveled' collagen fibrils. We investigated this proposal by attempting to weld highly collagenous, avascular corneal tissue with an infrared (IR) diode laser as follows. First, the temperature at which corneal collagen shrinks and collagen fibrils 'split' into subfibrillary components was determined. Second, since use of a near-IR laser wavelength necessitated addition of an absorbing dye (indocyanine green (ICG) to the cornea, we measured absorption spectra of ICG-treated tissue to ensure that peak ICG absorbance did not change markedly when ICG was present in the cornea. Third, using gel electrophoresis of thermally altered corneal collagen, we searched for covalently crosslinked compounds predicted by the proposed welding mechanism. Finally, we attempted to weld partial thickness corneal incisions infused with ICG. Principal experimental findings were as follows: (1) Human corneal (type I) collagen splits into subfibrillary components at approximately 63 degree(s)C, the same temperature that produces collagen shrinkage. (2) Peak ICG absorption does not change significantly in corneal stroma or with laser heating. (3) No evidence was found for the formation of novel compounds or the loss of proteins as a result of tissue heating. All tissue treated with ICG, however, exhibited a novel 244 kD protein band indicating chemical activity between collagen and corneal stromal components. (4) Laser welding corneal incisions was unsuccessful possibly due to shrinkage of the sides of the incision, lack of incision compression during heating, or a less than optimal combination of ICG concentration and radiant exposure. In summary, these experiments demonstrate the biochemical and morphological complexity of ICG-enhanced IR laser-tissue welding and the need for further investigation of laser welding mechanisms.

  10. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  11. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  12. Intradermal indocyanine green for in vivo fluorescence laser scanning microscopy of human skin: a pilot study.

    Directory of Open Access Journals (Sweden)

    Constanze Jonak

    Full Text Available BACKGROUND: In clinical diagnostics, as well as in routine dermatology, the increased need for non-invasive diagnosis is currently satisfied by reflectance laser scanning microscopy. However, this technique has some limitations as it relies solely on differences in the reflection properties of epidermal and dermal structures. To date, the superior method of fluorescence laser scanning microscopy is not generally applied in dermatology and predominantly restricted to fluorescein as fluorescent tracer, which has a number of limitations. Therefore, we searched for an alternative fluorophore matching a novel skin imaging device to advance this promising diagnostic approach. METHODOLOGY/PRINCIPAL FINDINGS: Using a Vivascope®-1500 Multilaser microscope, we found that the fluorophore Indocyanine-Green (ICG is well suited as a fluorescent marker for skin imaging in vivo after intradermal injection. ICG is one of few fluorescent dyes approved for use in humans. Its fluorescence properties are compatible with the application of a near-infrared laser, which penetrates deeper into the tissue than the standard 488 nm laser for fluorescein. ICG-fluorescence turned out to be much more stable than fluorescein in vivo, persisting for more than 48 hours without significant photobleaching whereas fluorescein fades within 2 hours. The well-defined intercellular staining pattern of ICG allows automated cell-recognition algorithms, which we accomplished with the free software CellProfiler, providing the possibility of quantitative high-content imaging. Furthermore, we demonstrate the superiority of ICG-based fluorescence microscopy for selected skin pathologies, including dermal nevi, irritant contact dermatitis and necrotic skin. CONCLUSIONS/SIGNIFICANCE: Our results introduce a novel in vivo skin imaging technique using ICG, which delivers a stable intercellular fluorescence signal ideal for morphological assessment down to sub-cellular detail. The application of

  13. Indocyanine green-assisted internal limiting membrane peeling in macular hole surgery: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yan Wu

    Full Text Available BACKGROUND: The opinion of application of indocyanine green (ICG in the macular hole surgery was contradictory. Here we conducted a meta-analysis to evaluate the effect of in internal limiting membrane (ILM peeling for macular hole surgery. METHODS AND FINDINGS: We searched electronic databases for comparative studies published before July 2012 of ILM peeling with and without ICG. Twenty-two studies including 1585 eyes were included. Visual acuity (VA improvement, including the postoperative rate of ≥20/40 VA gained (OR, 0.65; 95% CI, 0.43 to 0.97; P = 0.033 and increased LogMAR (WMD, -0.09; 95% CI, -0.16 to -0.02; P = 0.011, was less in the ICG group. The risk of visual field defects was greater in the ICG group than in the non-ICG group. There was no significant difference in the rate of anatomical outcomes between ILM peeling procedures performed with and without ICG. RPE changes and other postoperative complications were not significantly different between the ICG and non-ICG groups. An additional analysis showed that the VA improvement of the ICG group was less than the non-ICG group only within the first year of follow up. A subgroup analysis showed that the rate of VA improvement was lower in the ICG group than in other adjuncts group. A higher rate of secondary closure and less VA improvement were observed in a high proportion (>0.1% of the ICG group. A sensitivity analysis after the randomized-controlled trials were excluded from the meta-analysis demonstrated no differences compared with the overall results. CONCLUSIONS: This meta-analysis demonstrated that there is no evidence of clinical superiority in outcomes for ICG-assisted ILM peeling procedure over the non-ICG one. The toxicity of ICG should be considered when choosing the various staining methods.

  14. The use of indocyanine green lymphography for the treatment of postoperative chylothorax with lipiodol lymphangiography in a 2-year-old child

    Directory of Open Access Journals (Sweden)

    Motoi Kato

    2017-08-01

    Full Text Available Postoperative chylothorax in infants prolongs hospital stay and possibly causes developmental delay because of its conservative treatment including inanition. Several medical and surgical treatments may be applied, but none constitute the absolute solution. Treatment with lipiodol during lymphangiography for postoperative chylothorax has been reported to be highly effective and less invasive in adults. On the other hand, few cases have been reported in infants. We demonstrate successful blockage of chyle leakage with lipiodol injection through the inguinal lymph node in a 2-year-old infant. The patient had undergone on-pump coarctectomy and chylothorax developed soon after surgery. Several medical treatments were partially effective, but the chest tube could not be removed because sequential aspiration was required to maintain a normal respiratory status. With the patient under general anesthesia, lipiodol injection combined with indocyanine green (ICG lymphography was performed. Lymphography combined with ICG significantly contributed not only to intraoperative detection of the inguinal lymph nodes but also to postoperative early detection of lymphedema caused by this procedure. This procedure required a simple maneuver and is probably applicable to other cases of traumatic chylothorax, such as after surgeries on the esophagus, trachea, or other components of the posterior mediastinum.

  15. Near-infrared fluorescence cholangiography with indocyanine green for biliary atresia. Real-time imaging during the Kasai procedure: a pilot study.

    Science.gov (United States)

    Hirayama, Yutaka; Iinuma, Yasushi; Yokoyama, Naoyuki; Otani, Tetsuya; Masui, Daisuke; Komatsuzaki, Naoko; Higashidate, Naruki; Tsuruhisa, Shiori; Iida, Hisataka; Nakaya, Kengo; Naito, Shinichi; Nitta, Koju; Yagi, Minoru

    2015-12-01

    Hepatoportoenterostomy (HPE) with the Kasai procedure is the treatment of choice for biliary atresia (BA) as the initial surgery. However, the appropriate level of dissection level of the fibrous cone (FC) of the porta hepatis (PH) is frequently unclear, and the procedure sometimes results in unsuccessful outcomes. Recently, indocyanine green near-infrared fluorescence imaging (ICG-FCG) has been developed as a form of real-time cholangiography. We applied this technique in five patients with BA to visualize the biliary flow at the PH intraoperatively. ICG was injected intravenously the day before surgery as the liver function test, and the liver was observed with a near-infrared camera system during the operation while the patient's feces was also observed. In all patients, the whole liver fluoresced diffusely with ICG-containing stagnant bile, whereas no extrahepatic structures fluoresced. The findings of the ICG fluorescence pattern of the PH after dissection of the FC were classified into three types: spotty fluorescence, one patient; diffuse weak fluorescence, three patients; and diffuse strong fluorescence, one patient. In all five patients, the feces evacuated after HPE showed distinct fluorescent spots, although that obtained before surgery showed no fluorescence. One patient with diffuse strong fluorescence who did not achieve JF underwent living related liver transplantation six months after the initial HPE procedure. Four patients, including three cases involving diffuse weak fluorescence and one case involving spotty fluorescence showed weak fluorescence compared to that of the surrounding liver surface. We were able to detect the presence of bile excretion at the time of HPE intraoperatively and successfully evaluated the extent of bile excretion using this new technique. Furthermore, the ICG-FCG findings may provide information leading to a new classification and potentially function as an indicator predicting the clinical outcomes after HPE.

  16. [Sentinel node detection using optonuclear probe (gamma and fluorescence) after green indocyanine and radio-isotope injections].

    Science.gov (United States)

    Poumellec, M-A; Dejode, M; Figl, A; Darcourt, J; Haudebourg, J; Sabah, Y; Voury, A; Martaens, A; Barranger, E

    2016-04-01

    Assess the biopsy's feasibility of the sentinel lymph node biopsy (SLNB) using optonuclear probe after of indocyanine green (ICG) and radio-isotope (RI) injections. Twenty-one patients with a localized breast cancer and unsuspicious axillary nodes underwent a SLNB after both injections of ICG and radio-isotope. One or more SLN were identified on the 21 patients (identification rate of 100%). The median number SLN was 2 (1-3). Twenty SLN were both radio-actives and fluorescents (54.1%), 11 fluorescent only (29.7%) and 6 were only radio-actives (16.2%). Seven patients had a metastatic SLN (8 SLN overall). Among them, only one had a micrometastasic SLN, 5 others had a macrometastatic SLN and one patient had two macrometastatic SLNs. Among the 8 metastatic SLN, 5 were both fluorescent and radioactive, 2 were only fluorescent and 1 was only radioactive. Detection SLN using optonuclear probe after indocyanine green and radio-isotope injections is effective and could be, after validation by randomized trial, a reliable alternative to the blue dye injection for teams who consider that combined detection as the reference. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Two Cases of Severe Degeneration of the Macula Following Vitrectomy with Indocyanine Green-Assisted Internal Limiting Membrane Peeling for Idiopathic Macular Hole

    OpenAIRE

    Inoue, Junji; Sakuma, Toshiro; Kiyokawa, Masatoshi; Kobayashi, Yasuhiko; Takebayashi, Hiroshi; Mizota, Atsushi; Tanaka, Minoru

    2008-01-01

    We describe three eyes of two cases of severe degeneration of the macula following vitrectomy with indocyanine green-assisted internal limiting membrane peeling for idiopathic macular hole. We need to remember the possibility of these complications and have to select the procedures that are safest to use for macular hole surgery.

  18. Hepatic blood flow determination. A comparison of 99mTc-diethyl-IDA and indocyanine green as hepatic blood flow indicators in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Winkler, K

    1987-01-01

    99mTc-diethyl-acetanilide-iminodiacetic acid (IDA) was compared with indocyanine green (ICG) as an indicator of hepatic blood flow (HBF). Twelve subjects (8 with cirrhosis, 2 with fatty liver, one with pancreatitis, and one with intestinal angina) were studied during hepatic vein catheterization...

  19. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    Science.gov (United States)

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye

  20. infrared spectrophotometer for simultaneous detection of traces of heavy water and indocyanine green in flowing blood. In vivo experimentation

    International Nuclear Information System (INIS)

    Capitini, R.; Roveyaz, P.

    1981-07-01

    We have developed an infrared absorption method for the pulmonary extravascular water and cardiac output determination by the multiple indicator technique. This led us to construct an original double differential spectrophotometer (DUPLEX) for simultaneous detection of traces of heavy water (D 2 O) and indocyanine green (ICG) in circulating blood in a single absorption cell. This DUPLEX is connected to a computer and results are treated on line. D 2 O and ICG are used as non toxic diffusible and vascular tracers respectively. Performances of the DUPLEX are given and show a high accuracy with D 2 O (x 10) and ICG (x 2) compared with the commercial optical analysers. We show the validity of the method for determining the cardiac output and the pulmonary extravascular water in the course of numerous experiments on human and rats subjects. Preliminary results concerning the measurement of global water on rats are also given [fr

  1. New technique for laryngotracheal mucosa transplantation. 'Stamp' welding using indocyanine green dye and albumin interaction with diode laser.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Gleich, L L; Rebeiz, E E; Shapshay, S M

    1995-07-01

    To investigate (1) the possibility of survival of free mucosa "stamp" grafts fixed in the airway with a new technique using indocyanine green-dyed albumin solder activated with a diode laser and (2) the degree of improvement of wound healing in the airway by applying modified microskin transplantation techniques from burn surgery to cover a relatively large wound with a few small pieces of mucosa anchored in place with the previously mentioned technique. Three (one control and two experimental) rectangular (10 x 8 mm) wounds in tracheal mucosa were produced in four experimental animals (dogs) using a carbon dioxide laser. The control wound was left uncovered. In the first experimental wound, a mucosal flap was raised and then fixed in place by a trapdoor flap method. In the second experimental wound, two small (each 2 x 3 mm) autogenous mucosa grafts were anchored onto the surface with indocyanine green-dyed albumin activated with an 810-nm diode laser. Histomorphologically, the postoperative results from three wounds were compared. The experimental wounds were completely covered by regenerated squamous cells in 1 week and by ciliated epithelium in 2 weeks after the operation despite the discrepancy in size of the graft to wound area (1:6.7) covered with the stamp mucosa. No thermal damage from the diode laser was noted in the second experimental wounds. In the control wounds, no coverage was observed at 1 week, and only squamous cells were noted 2 weeks postoperatively. All the wounds had normal ciliated epithelium coverage at 4 weeks. Transplanted stamp grafts provided similar or better healing than trapdoor flap transplants. This new technique made endoscopic mucosal grafting possible and offers a potential breakthrough in the management of laryngotracheal stenosis.

  2. Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental proof of the concept.

    Science.gov (United States)

    Diana, Michele; Liu, Yu-Yin; Pop, Raoul; Kong, Seong-Ho; Legnèr, Andras; Beaujeux, Remy; Pessaux, Patrick; Soler, Luc; Mutter, Didier; Dallemagne, Bernard; Marescaux, Jacques

    2017-03-01

    Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego ® , multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n = 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n = 1). Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.

  3. Tailoring through Technology: A Retrospective Review of a Single Surgeon's Experience with Implant-Based Breast Reconstruction before and after Implementation of Laser-Assisted Indocyanine Green Angiography.

    Science.gov (United States)

    Harless, Christin A; Jacobson, Steven R

    2016-05-01

    Reported complication rates of implant-based breast reconstruction in the literature exceed 50%, with mastectomy skin flap necrosis reported to occur in up to 25% of cases. Laser-assisted indocyanine green angiography (LA-ICGA) technology allows the surgeon to optimize preservation of the mastectomy skin flap while avoiding skin necrosis. The purpose of this study was to determine if outcomes of breast reconstruction are beneficially affected by using LA-ICGA. A total 269 consecutive women (467 breast reconstructions) undergoing implant-based breast reconstruction from 2008 to 2013 were examined. The complication rates of those who underwent reconstruction prior to the implementation of LA-ICGA were compared with those who were reconstructed after implementation of LA-ICGA. A total of 254 consecutive breast reconstructions were performed prior to implementation of LA-ICGA, and 213 breasts were reconstructed with the use of LA-ICGA. After implementation of LA-ICGA System, the rate of mastectomy skin flap necrosis decreased by 86% (6.7% versus 0.9%, p = 0.02). The overall complication rate prior to LA-ICGA was 13.8% compared with 6.6% with the use of LA-ICGA (p = 0.01). After LA-ICGA was incorporated, the percentage of patients undergoing single-stage reconstruction increased from 12% to 32% (p = <0.001). Implementation of LA-ICGA provides the surgeon with an objective assessment of mastectomy flap perfusion resulting in a trend toward overall reduction in complications as well as an 86% decrease in the rate of subsequent skin necrosis. The objective assessment of mastectomy flap perfusion allows the surgeon to tailor breast reconstruction intraoperatively, in real-time, adjusting for the individual patient's mastectomy flap perfusion. © 2016 Wiley Periodicals, Inc.

  4. Blood flow index using near-infrared spectroscopy and indocyanine green as a minimally invasive tool to assess respiratory muscle blood flow in humans

    DEFF Research Database (Denmark)

    Guenette, Jordan A; Henderson, William R; Dominelli, Paolo B

    2011-01-01

    Near-infrared spectroscopy (NIRS) in combination with indocyanine green (ICG) dye has recently been used to measure respiratory muscle blood flow (RMBF) in humans. This method is based on the Fick principle and is determined by measuring ICG in the respiratory muscles using transcutaneous NIRS...... relationships with the work of breathing and EMG for both respiratory muscles. The coefficients of determination (R(2)) comparing BFI vs. the work of breathing for the intercostal and sternocleidomastoid muscles were 0.887 (P

  5. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  6. Indocyanine Green-Loaded Polydopamine-Reduced Graphene Oxide Nanocomposites with Amplifying Photoacoustic and Photothermal Effects for Cancer Theranostics.

    Science.gov (United States)

    Hu, Dehong; Zhang, Jingnan; Gao, Guanhui; Sheng, Zonghai; Cui, Haodong; Cai, Lintao

    2016-01-01

    Photoacoustic (PA) imaging and photothermal therapy (PTT) as light-induced theranostic platforms have been attracted much attention in recent years. However, the development of highly efficient and integrated phototheranostic nanoagents for amplifying PA imaging and PTT treatments poses great challenges. Here, we report a novel phototheranostic nanoagent using indocyanine green-loaded polydopamine-reduced graphene oxide nanocomposites (ICG-PDA-rGO) with amplifying PA and PTT effects for cancer theranostics. The results demonstrate that the PDA layer coating on the surface of rGO could effectively absorb a large number of ICG molecules, quench ICG's fluorescence, and enhance the PDA-rGO's optical absorption at 780 nm. The obtained ICG-PDA-rGO exhibits stronger PTT effect and higher PA contrast than that of pure GO and PDA-rGO. After PA imaging-guided PTT treatments, the tumors in 4T1 breast subcutaneous and orthotopic mice models are suppressed completely and no treatment-induced toxicity being observed. It illustrates that the ICG-PDA-rGO nanocomposites constitute a new class of theranostic nanomedicine for amplifying PA imaging and PTT treatments.

  7. Use of invisible near infrared light fluorescence with indocyanine green and methylene blue in urology. Part 2.

    Science.gov (United States)

    Polom, Wojciech; Markuszewski, Marcin; Rho, Young Soo; Matuszewski, Marcin

    2014-01-01

    In the second part of this paper, concerning the use of invisible near infrared light (NIR) fluorescence with indocyanine green (ICG) and methylene blue (MB) in urology, other possible uses of this new technique will be presented. In kidney transplantation, this concerns allograft perfusion and real time NIR-guided angiography; moreover, perfusion angiography of tissue flaps, NIRF visualization of ureters, NIR-guided visualization of urinary calcifications, NIRF in male infertility and semen quality assessment. In this part, we have also analysed cancer targeting and imaging fluorophores as well as cost benefits associated with the use of these new techniques. PubMed and Medline databases were searched for ICG and MB use in urological settings, along with data published in abstracts of urological conferences. Although NIR-guided ICG and MB are still in their initial phases, there have been significant developments in a few more major domains of urology, including 1) kidney transplantation: kidney allograft perfusion and vessel reconstruction; 2) angiography perfusion of tissue flaps; 3) visualization of ureters; 4) visualization of urinary calcifications; and 5) NIRF in male infertility and semen quality assessment. Near infrared technology in urology is at its early stages. More studies are needed to assess the true potential and limitations of the technology. Initial studies show that this pioneering tool may influence various aspects of urology.

  8. Preliminary study of laser welding for aortic dissection in a porcine model using a diode laser with indocyanine green.

    Science.gov (United States)

    Fujita, Masanori; Morimoto, Yuji; Ohmori, Sayaka; Usami, Noriko; Arai, Tsunenori; Maehara, Tadaaki; Kikuchi, Makoto

    2003-01-01

    The objective of this study was to determine whether a dissected aorta could be welded by a diode laser with a solder using an in vitro porcine aortic dissection model. Porcine aortic strips were dissected into two flaps and the dissected faces were immersed in a solution of indocyanine green. The two flaps were pressed at 0.2 kg/cm2 with contact between the two immersed faces. The pressed flaps were irradiated with a diode laser (810 nm) at intensities of 170-425 W/cm2 for 8 seconds. The welded flaps were studied by light microscopy and the adhesive strengths were measured. The irradiated flaps were successfully welded. The breaking stress, the maximum stress recorded in a stress-strain curve, increased with increase in irradiation intensity up to 396 W/cm2 (2.7 x 10(2) mmHg) and decreased when the intensity reached 425 W/cm2. In the specimen irradiated at 396 W/cm2, the welded faces showed continuous fusion of elastin layers, while some voids were seen between the welded faces in the specimen irradiated at 425 W/cm2. The dissected porcine aortas were successfully welded using a laser with solder. The results suggest that the welded aorta can bear physiological blood pressure. Copyright 2003 Wiley-Liss, Inc.

  9. Detection of posterior vortex veins in eyes with pathologic myopia by ultra-widefield indocyanine green angiography.

    Science.gov (United States)

    Moriyama, Muka; Cao, Kejia; Ogata, Satoko; Ohno-Matsui, Kyoko

    2017-09-01

    To analyse the characteristics of posterior vortex veins detected in highly myopic eyes by wide-field indocyanine green angiography (ICGA). One hundred and fifty-eight consecutive patients (302 eyes) with high myopia (myopic refractive error >8.0 dioptres (D) or axial length ≥26.5 mm) were studied. Wide-field ICGA was performed with the Spectralis HRA module. Posterior vortex veins were found in 80 eyes (26%). The prevalence of posterior staphyloma was significantly higher in eyes in which posterior vortex vein was detected than in eyes without posterior vortex vein. The posterior vortex veins were classified into five types according to the site of exit from the eye; around the optic nerve in 28%, in the macular area in 17%, along the border of staphyloma in 6%, along the margin of macular atrophy or large peripapillary conus in 21%, and elsewhere in 28%. In one eye, two posterior vortex veins collected the choroidal venous blood from the entire fundus. Wide-field ICGA can analyse the characteristic features of choroidal blood outflow system through posterior vortex veins in highly myopic eyes. They may play an important role as routes of choroidal outflow in highly myopic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. A novel duct-lobular segmentectomy for breast tumors with nipple discharge using near-infrared indocyanine green fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohno

    2013-10-01

    Full Text Available A 44-year-old woman was referred to our hospital with pathological nipple discharge from her left breast. Ultrasonography revealed a solid tumor beneath her left areola that measured 17 mm in diameter with a dilated mammary duct. Contrast-enhanced magnetic resonance imaging showed an early-enhanced cystic tumor and a dilated mammary duct. We performed a duct-lobular segmentectomy using near-infrared indocyanine green (ICG-fluorescence imaging. Under general anesthesia, a silicone tube was inserted into an orifice of a fluid-discharging mammary duct, and 1 mL dye-fluorescence liquid containing ICG and indigo carmine was injected into the mammary duct. A periareolar incision was made, and the fluorescence image of the demarcated mammary duct segment was obtained. The mammary duct segment was dissected, along with the demarcation line. The cystic lesion and dilated mammary duct were fully resected, and the pathological diagnosis was intraductal papilloma of the breast. We report that near-infrared ICG fluorescence could be applied for imaging of the mammary duct segment, and the fluorescence image allowed for easier duct-lobular segmentectomy for nipple discharge.

  11. 1,213 Cases of Treatment of Facial Acne Using Indocyanine Green and Intense Pulsed Light in Asian Skin

    Directory of Open Access Journals (Sweden)

    Kui Young Park

    2015-01-01

    Full Text Available Background. Photodynamic therapy (PDT has been used for acne, with various combinations of photosensitizers and light sources. Objective. We evaluated the effectiveness and safety of indocyanine green (ICG and intense pulsed light (IPL in the treatment of acne. Materials and Methods. A total of 1,213 patients with facial acne were retrospectively reviewed. Patients received three or five treatments of ICG and IPL at two-week intervals. Clinical response to treatment was assessed by comparing pre- and posttreatment clinical photographs and patient satisfaction scores. Results. Marked to excellent improvement was noted in 483 of 1,213 (39.8% patients, while minimal to moderate improvement was achieved in the remaining 730 (60.2% patients. Patient satisfaction scores revealed that 197 (16.3% of 1,213 patients were highly satisfied, 887 (73.1% were somewhat satisfied, and 129 (10.6% were unsatisfied. There were no significant side effects. Conclusion. These results suggest that PDT with ICG and IPL can be effectively and safely used in the treatment of acne.

  12. Indocyanine Green Angiographic and Multifocal Electroretinographic Features in the Diffuse and Regional Form of Bietti′s Crystalline Retinopathy

    Institute of Scientific and Technical Information of China (English)

    Libin Jiang; Feng Wen; Lezheng Wu; Hong Yan; Shixing Hu

    2002-01-01

    Prpose: To observe different features of indocyanine green angiography(ICGA) andtifocal electroretinography (ERG) in the diffuse and regional type of Bieti′sc stalline retinopathy (BCR). Thods: ICGA and the multifocal ERG were performed in two cases of the diffuse andregional type of BCR respectively. These data were compared with fluoresceinangiography (FA), standard Ganzfeld ERG, and visual field testing. Results: In the regional case, ICGA revealed reduced perfusion of the choroidalcirculation in the early phase and multiple hypofluorescent spots in the posterior pole in the late phase, due to choriocapillaris filling defect; the extent of choroiocapillaris losswas shown in early phase of ICGA and there were multifocal hyperfluorescent dotssurrounding hypofluorescent spots in late phase in the diffuse case. The multifocal ERGshowed that the central responses were markedly depressed, corresponding to the visualfield defects, while the findings of Ganzfeld ERG were normal in the regional BCR;however, both the multifocal ERG and Ganzfeld ERG were severely subnormal in thediffuse case.Conclusions: The features of ICGA and multifocal ERG are different between the diffuseand regional BCR. In the meantime, the two tools are also useful to differentiate the typeand assess the extentof evolution in BCR.

  13. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  14. Assessing pharmacokinetics of indocyanine green-loaded nanoparticle in tumor with a dynamic diffuse fluorescence tomography system

    Science.gov (United States)

    Zhang, Yanqi; Yin, Guoyan; Zhao, Huijuan; Ma, Wenjuan; Gao, Feng; Zhang, Limin

    2018-02-01

    Real-time and continuous monitoring of drug release in vivo is an important task in pharmaceutical development. Here, we devoted to explore a real-time continuous study of the pharmacokinetics of free indocyanine green (ICG) and ICG loaded in the shell-sheddable nanoparticles in tumor based on a dynamic diffuse fluorescence tomography (DFT) system: A highly-sensitive dynamic DFT system of CT-scanning mode generates informative and instantaneous sampling datasets; An analysis procedure extracts the pharmacokinetic parameters from the reconstructed time curves of the mean ICG concentration in tumor, using the Gauss-Newton scheme based on two-compartment model. Compared with the pharmacokinetic parameters of free ICG in tumor, the ICG loaded in the shell-sheddable nanoparticles shows efficient accumulation in tumor. The results demonstrate our proposed dynamic-DFT can provide an integrated and continuous view of the drug delivery of the injected agents in different formulations, which is helpful for the development of diagnosis and therapy for tumors.

  15. Utility of Indocyanine Green Video Angiography for Sylvian Fissure Dissection in Subarachnoid Hemorrhage Patients - Sylvian ICG Technique.

    Science.gov (United States)

    Toi, Hiroyuki; Matsushita, Nobuhisa; Ogawa, Yukari; Kinoshita, Keita; Satoh, Kohei; Takai, Hiroki; Hirai, Satoshi; Hara, Keijiro; Matsubara, Shunji; Uno, Masaaki

    2018-02-15

    Indocyanine green (ICG) emits fluorescence in the far-red domain under light excitation. ICG video angiography (ICG-VA) has been established as a useful method to evaluate blood flow in the operative field. We report the usefulness of ICG-VA for Sylvian fissure dissection in patients with subarachnoid hemorrhage (SAH). Subjects comprised 7 patients who underwent ICG-VA before opening the Sylvian fissure during neck clipping for ruptured cerebral aneurysm. We observed contrasted Sylvian veins before opening the Sylvian fissure using surgical microscopes. This procedure was termed "Sylvian ICG". We observed ICG fluorescence quickly in all cases. Sylvian veins that appeared unclear in the standard microscopic operative field covered with subarachnoid hemorrhage were extremely clearly depicted. These Sylvian ICG findings were helpful in identifying entry points and the dissecting course of the Sylvian fissure. At the time of clipping, no residual fluorescence from Sylvian ICG was present, and aneurysm clipping was not impeded. Sylvian ICG for SAH patients is a novel technique to facilitate dissection of the Sylvian fissure. We believe that this technique will contribute to improved safety of clipping surgery for ruptured aneurysms.

  16. Effects of nanoencapsulation and PEGylation on biodistribution of indocyanine green in healthy mice: quantitative fluorescence imaging and analysis of organs

    Directory of Open Access Journals (Sweden)

    Bahmani B

    2013-04-01

    Full Text Available Baharak Bahmani,1 Christian Y Lytle,2 Ameae M Walker,2 Sharad Gupta,1 Valentine I Vullev,1 Bahman Anvari1 1Department of Bioengineering, 2Division of Biomedical Sciences, University of California, Riverside, CA, USA Abstract: Near-infrared nanoconstructs present a potentially effective platform for site-specific and deep tissue optical imaging and phototherapy. We have engineered a polymeric nanocapsule composed of polyallylamine hydrochloride (PAH chains cross-linked with sodium phosphate and doped with indocyanine green (ICG toward such endeavors. The ICG-doped nanocapsules were coated covalently with polyethylene glycol (5000 daltons through reductive amination. We administrated the constructs by tail vein injection to healthy mice. To characterize the biodistribution of the constructs, we performed in vivo quantitative fluorescence imaging and subsequently analyzed the various extracted organs. Our results suggest that encapsulation of ICG in these PEGylated constructs is an effective approach to prolong the circulation time of ICG and delay its hepatic accumulation. Increased bioavailability of ICG, due to encapsulation, offers the potential of extending the clinical applications of ICG, which are currently limited due to rapid elimination of ICG from the vasculature. Our results also indicate that PAH and ICG-doped nanocapsules (ICG-NCs are not cytotoxic at the levels used in this study. Keywords: cancer, fluorescent imaging, nanoprobes, near infrared, pharmacokinetics, phototherapy, vascular imaging

  17. Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain

    Science.gov (United States)

    Gerega, Anna; Milej, Daniel; Weigl, Wojciech; Botwicz, Marcin; Zolek, Norbert; Kacprzak, Michal; Wierzejski, Wojciech; Toczylowska, Beata; Mayzner-Zawadzka, Ewa; Maniewski, Roman; Liebert, Adam

    2012-08-01

    Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is presented and advantages of measurements at multiple wavelengths are discussed. Measurements were carried out: 1. on a physical homogeneous phantom to study the concentration dependence of the fluorescence signal, 2. on the phantom to simulate the dynamic inflow of ICG at different depths, and 3. in vivo on surface of the human head. Pattern of inflow and washout of ICG in the head of healthy volunteers after intravenous injection of the dye was observed for the first time with time-resolved instrumentation at multiple emission wavelengths. The multiwavelength detection of fluorescence signal confirms that at longer emission wavelengths, probability of reabsorption of the fluorescence light by the dye itself is reduced. Considering different light penetration depths at different wavelengths, and the pronounced reabsorption at longer wavelengths, the time-resolved multiwavelength technique may be useful in signal decomposition, leading to evaluation of extra- and intracerebral components of the measured signals.

  18. Sentinel Node Mapping Using Indocyanine Green and Near-infrared Fluorescence Imaging Technology for Uterine Malignancies: Preliminary Experience With the Da Vinci Xi System.

    Science.gov (United States)

    Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico

    2016-01-01

    Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No

  19. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    Science.gov (United States)

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  20. Near-infrared fluorescence imaging and photodynamic therapy with indocyanine green lactosome has antineoplastic effects for hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Takumi Tsuda

    Full Text Available Anticancer agents and operating procedures have been developed for hepatocellular carcinoma (HCC patients, but their prognosis remains poor. It is necessary to develop novel diagnostic and therapeutic strategies for HCC to improve its prognosis. Lactosome is a core-shell-type polymeric micelle, and enclosing labeling or anticancer agents into this micelle enables drug delivery. In this study, we investigated the diagnostic and therapeutic efficacies of indocyanine green (ICG-loaded lactosome for near-infrared fluorescence (NIF imaging and photodynamic therapy (PDT for HCC.The human HCC cell line HuH-7 was treated with ICG or ICG-lactosome, followed by PDT, and the cell viabilities were measured (in vitro PDT efficiency. For NIF imaging, HuH-7 cells were subcutaneously transplanted into BALB/c nude mice, followed by intravenous administration of ICG or ICG-lactosome. The transplanted animals were treated with PDT, and the antineoplastic effects were analyzed (in vivo PDT efficiency.PDT had toxic effects on HuH-7 cells treated with ICG-lactosome, but not ICG alone. NIF imaging revealed that the fluorescence of tumor areas in ICG-lactosome-treated animals was higher than that of contralateral regions at 24 h after injection and thereafter. PDT exerted immediate and continuous phototoxic effects in the transplanted mice treated with ICG-lactosome.Our results demonstrate that ICG-lactosome accumulated in xenograft tumors, and that PDT had antineoplastic effects on these malignant implants. NIF imaging and PDT with ICG-lactosome could be useful diagnostic and/or therapeutic strategies for HCC.

  1. Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study.

    Science.gov (United States)

    Boni, Luigi; Fingerhut, Abe; Marzorati, Alessandro; Rausei, Stefano; Dionigi, Gianlorenzo; Cassinotti, Elisa

    2017-04-01

    Colorectal anastomoses after anterior resection for cancer carry a high risk of leakage. Different factors might influence the correct healing of anastomosis, but adequate perfusion of the bowel is highlighted as one of the most important elements. Fluorescence angiography (FA) is a new technique that allows the surgeon to perform real-time intraoperative angiography to evaluate the perfusion of the anastomosis and hence, potentially, reduce leak rate. The aim of this study was to evaluate the impact of FA of the bowel on postoperative complications and anastomotic leakage after laparoscopic anterior resection with total mesorectal excision (TME). FA was performed in all patients undergoing laparoscopic anterior resection with TME for cancer followed by colorectal or coloanal anastomosis. Results were compared to a historical controls group of 38 patients previously operated by the same surgeon for the same indication but without the use of FA. From October 2014 to November 2015, 42 patients underwent laparoscopic anterior resection with TME and FA of the bowel. The surgeon subjectively decided to change the planned anastomotic level of the descending colon due to hypoperfused distal segment in two out of 42 patients in the FA group (4.7 %). Anastomotic leakage, confirmed by postoperative CT scan and water-soluble contrast enema, was found in two cases of a historical controls group and none in the FA group. No adverse events (side effects or allergic reaction) related to FA were recorded. All the other postoperative complications were comparable between the two groups. In our experience, ICG FA was safe and effective in low rectal cancer resection, possibly leading to a reduction in the anastomotic leakage rate after TME.

  2. Pilot Assessment of the Repeatability of Indocyanine Green Fluorescence Imaging and Correlation with Traditional Foot Perfusion Assessments.

    Science.gov (United States)

    Venermo, M; Settembre, N; Albäck, A; Vikatmaa, P; Aho, P-S; Lepäntalo, M; Inoue, Y; Terasaki, H

    2016-10-01

    Ankle brachial index (ABI), toe pressures (TP), and transcutaneous oxygen pressure (TcPO 2 ) are traditionally used in the assessment of critical limb ischemia (CLI). Indocyanine green (ICG) fluorescence imaging can be used to evaluate local circulation in the foot and to evaluate the severity of ischemia. This prospective study analyzed the suitability of a fluorescence imaging system (photodynamic eye [PDE]) in CLI. Forty-one patients with CLI were included. Of the patients, 66% had diabetes and there was an ischemic tissue lesion in 70% of the limbs. ABI, toe pressures, TcPO 2 and ICG-fluorescence imaging (ICG-FI) were measured in each leg. To study the repeatability of the ICG-FI, each patient underwent the study twice. After the procedure, foot circulation was measured using a time-intensity curve, where T1/2 (the time needed to achieve half of the maximum fluorescence intensity) and PDE10 (increase of the intensity during the first 10 s) were determined. A time-intensity curve was plotted using the same areas as for the TcPO 2 probes (n=123). The mean ABI was 0.43, TP 21 mmHg, TcPO 2 23 mmHg, T1/2 38 s, and PDE10 19 AU. Time-intensity curves were repeatable. In a Bland-Altman scatter plot, the 95% limits of agreement of PDE10 was 9.9 AU and the corresponding value of T1/2 was 14 s. Correlation between ABI and TP was significant (R=.73, p<.001), and it was weaker in diabetic patients (R=.47, p=.048) compared with non-diabetic patients (R=.89, p=.002). Correlations between ABI and TcPO 2 and TP and TcPO 2 were weak (R=.37, p=.05 and R=.43, p=.037, respectively). Correlation between TcPO 2 and PDE10 was strong in diabetic patients (R=.70, p=.003). According to this pilot study, ICG-FI with PDE can be used in the assessment of blood supply in the ischemic foot. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Imaging of pharmacokinetic rates of indocyanine green in mouse liver with a hybrid fluorescence molecular tomography/x-ray computed tomography system.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Zhang, Bin; He, Yun; Luo, Jianwen; Bai, Jing

    2013-04-01

    Pharmacokinetic rates have the potential to provide quantitative physiological and pathological information for biological studies and drug development. Fluorescence molecular tomography (FMT) is an attractive imaging tool for three-dimensionally resolving fluorophore distribution in small animals. In this letter, pharmacokinetic rates of indocyanine green (ICG) in mouse liver are imaged with a hybrid FMT and x-ray computed tomography (XCT) system. A recently developed FMT method using structural priors from an XCT system is adopted to improve the quality of FMT reconstruction. In the in vivo experiments, images of uptake and excretion rates of ICG in mouse liver are obtained, which can be used to quantitatively evaluate liver function. The accuracy of the results is validated by a fiber-based fluorescence measurement system.

  4. Indocyanine green labeled with /sup 123/I for dynamic studies of the hepato-biliary system. [/sup 131/I, /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub /sup 1///sub 2// = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of /sup 123/I-ICG (in dogs) will be compared to /sup 131/I-rose bengal and bromosulphalein labeled with iodine-125.

  5. Fluorescent Imaging With Indocyanine Green During Laparoscopic Cholecystectomy in Patients at Increased Risk of Bile Duct Injury

    NARCIS (Netherlands)

    Ankersmit, M.; Dam, D.A. van; Rijswijk, A.S. van; Tuynman, J.B.; Meijerink, W.J.H.J.

    2017-01-01

    BACKGROUND: Although rare, injury to the common bile duct (CBD) during laparoscopic cholecystectomy (LC) can be reduced by better intraoperative visualization of the cystic duct (CD) and CBD. The aim of this study was to establish the efficacy of early visualization of the CD and the added value of

  6. Development of PLGA-lipid nanoparticles with covalently conjugated indocyanine green as a versatile nanoplatform for tumor-targeted imaging and drug delivery

    Directory of Open Access Journals (Sweden)

    Xin Y

    2016-11-01

    Full Text Available Yu Xin, Tie Liu, Chenlong Yang Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, People’s Republic of China Abstract: We have prepared novel poly(d,l-lactide-co-glycolide (PLGA lipid nanoparticles (PNPs that covalently conjugate folic acid (FA and indocyanine green (ICG, in addition to encapsulating resveratrol (RSV (FA-RSV/ICG-PLGA-lipid NPs, abbreviated as FA-RIPNPs; these nanoparticles have been developed for simultaneous targeted delivery of anticancer drug and fluorescence imaging. The FA-RIPNPs, with an average particle size of 92.8±2.1 nm, were prepared by a facile self-assembly-and-nanoprecipitation method, and they showed excellent stability and biocompatibility characteristics. The FA-RIPNPs exhibited an RSV encapsulation efficiency of approximately 65.6%±4.7% and a maximum release ratio of 78.2%±4.1% at pH 5.0 and 37°C. Confocal fluorescence images showed that FA-RIPNPs may facilitate a high cellular uptake via FA receptor-mediated endocytosis. Furthermore, FA-RIPNPs (containing 50 µg/mL RSV induced a 81.4%±2.1% U87 cell inhibition rate via apoptosis, a value that proved to be higher than what has been shown for free RSV (53.1%±1.1%, equivalent RSV concentration. With a formulated polyethylene glycol (PEG shell around the PLGA core, FA-RIPNPs prolonged the blood circulation of both free RSV and ICG, which approximately increased 6.96- and 39.4-fold (t1/2, respectively. Regarding FA-RIPNP use as a near-infrared probe, in vivo fluorescence images indicated a highly efficient accumulation of FA-RIPNPs in the tumor tissue, which proved to be approximately 2.8- and 12.6-fold higher than the RIPNPs and free ICG, respectively. Intravenous injection of FA-RIPNPs into U87 tumor-bearing mice demonstrated the best tumor inhibition effect for all tested drugs, including free RSV and RIPNPs, with no relapse, showing high biocompatibility and with no significant systemic in vivo toxicity over the

  7. Real-time navigation system for sentinel lymph node biopsy in breast cancer patients using projection mapping with indocyanine green fluorescence.

    Science.gov (United States)

    Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu

    2018-05-09

    Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.

  8. Prussian blue/serum albumin/indocyanine green as a multifunctional nanotheranostic agent for bimodal imaging guided laser mediated combinatorial phototherapy.

    Science.gov (United States)

    Sahu, Abhishek; Lee, Jong Hyun; Lee, Hye Gyeong; Jeong, Yong Yeon; Tae, Giyoong

    2016-08-28

    Developing novel nanotheranostic agent using only clinically approved materials is highly desirable and challenging. In this study, we combined three clinically approved materials, Prussian blue (PB), serum albumin (BSA), and indocyanine green (ICG), by a simple and biocompatible method to prepare a multifunctional theranostic PB-BSA-ICG nanoparticle. The multifunctional nanoparticle system could provide dual mode magnetic resonance (MR) and near infrared (NIR) fluorescence imaging as well as combined photothermal and photodynamic (PTT-PDT) therapy in response to a single NIR laser. This nanoparticle showed an excellent stability in physiological solutions and could suppress the photo-instability of ICG. In the absence of light, the nanoparticles showed no cytotoxicity, but significant cell death was induced through combined PTT-PDT effect after irradiation with NIR laser light. A high tumor accumulation and minimal nonspecific uptake by other major organs of PB-BSA-ICG nanoparticle were observed in vivo, analyzed by T1-weighted MR and NIR fluorescence bimodal imaging in tumor xenograft mice after intravenous injection. The nanoparticles efficiently suppressed the tumor growth through combinatorial phototherapy with no tumor recurrence upon a single NIR laser irradiation. These results demonstrated that PB-BSA-ICG is potentially an interesting nanotheranostic agent for imaging guided cancer therapy by overcoming the limitations of each technology and enhancing the therapeutic efficiency as well as reducing side effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A Near-Infrared Photothermal Effect-Responsive Drug Delivery System Based on Indocyanine Green and Doxorubicin-Loaded Polymeric Micelles Mediated by Reversible Diels-Alder Reaction.

    Science.gov (United States)

    Li, Hui; Li, Junjie; Ke, Wendong; Ge, Zhishen

    2015-10-01

    Near-infrared light (NIR) possesses great advantages for light-responsive controllable drug release, such as deep tissue penetration and low damage to healthy tissues. Herein, a NIR-responsive drug delivery system is developed based on a NIR dye, indocyanine green (ICG), and anticancer drug, doxorubicin (DOX)-loaded thermoresponsive block copolymer micelles, in which the drug release can be controlled via NIR irradiation. First, block copolymers, poly(oligo(ethylene glycol) methacrylate)-block-poly(furfuryl methacrylate) (POEGMA-b-PFMA), are synthesized by sequential reversible addition-fragmentation chain-transfer (RAFT) polymerization, followed by modification with N-octyl maleimide through Diels-Alder (DA) reaction to produce POEGMA-b-POMFMA. The self-assembly of POEGMA-b-POMFMA by nano-precipitation in aqueous solution affords the polymeric micelles which are used to simultaneously encapsulate ICG and DOX. Upon irradiation by NIR light (805 nm), the loaded DOX is released rapidly from the micelles due to partial retro DA reaction and local temperature increase-induced faster drug diffusion by the photothermal effect. Cytotoxicity evaluation and intracellular distribution observation demonstrate significant synergistic effects of NIR-triggered drug release, photothermal, and chemotherapy toward cancer cells under NIR irradiation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The Predictive Value of Indocyanine Green Clearance in Future Liver Remnant for Posthepatectomy Liver Failure Following Hepatectomy with Extrahepatic Bile Duct Resection.

    Science.gov (United States)

    Yokoyama, Yukihiro; Ebata, Tomoki; Igami, Tsuyoshi; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Nagino, Masato

    2016-06-01

    Postoperative liver failure (PHLF) is one of the most common complications following major hepatectomy. The preoperative assessment of future liver remnant (FLR) function is critical to predict the incidence of PHLF. To determine the efficacy of the plasma clearance rate of indocyanine green clearance of FLR (ICGK-F) in predicting PHLF in cases of highly invasive hepatectomy with extrahepatic bile duct resection. Five hundred and eighty-five patients who underwent major hepatectomy with extrahepatic bile duct resection, from 2002 to 2014 in a single institution, were evaluated. Among them, 192 patients (33 %) had PHLF. The predictive value of ICGK-F for PHLF was determined and compared with other risk factors for PHLF. The incidence of PHLF was inversely proportional to the level of ICGK-F. With multivariate logistic regression analysis, ICGK-F, combined pancreatoduodenectomy, the operation time, and blood loss were identified as independent risk factors of PHLF. The risk of PHLF increased according to the decrement of ICGK-F (the odds ratio of ICGK-F for each decrement of 0.01 was 1.22; 95 % confidence interval 1.12-1.33; P bile duct resection. This criterion may be useful for highly invasive hepatectomy, such as that with extrahepatic bile duct resection.

  11. Detection of peritoneal dissemination with near-infrared fluorescence laparoscopic imaging using a liposomal formulation of a synthesized indocyanine green liposomal derivative.

    Science.gov (United States)

    Hoshino, Isamu; Maruyama, Tetsuro; Fujito, Hiromichi; Tamura, Yutaka; Suganami, Akiko; Hayashi, Hideki; Toyota, Taro; Akutsu, Yasunori; Murakami, Kentaro; Isozaki, Yuka; Akanuma, Naoki; Takeshita, Nobuyoshi; Toyozumi, Takeshi; Komatsu, Aki; Matsubara, Hisahiro

    2015-03-01

    Although conventional staging laparoscopy (SL) has improved the diagnostic accuracy of peritoneal dissemination, novel technology is needed to increase the sensitivity of SL. We herein describe a new imaging method employing near-infrared (NIR) fluorescence imaging using a liposomal synthesized indocyanine green (ICG) liposomal derivative, LP-ICG-C18. LP-ICG-C18 is a NIR-photoactivating probe in which an ICG fluorophore is covalently conjugated with a phospholipid moiety. Nude mice were intraperitoneally injected with gastric cancer cells. Twelve days later, the mice were given intravenous injections of LP-ICG-C18 at a dose of 0.15 mg/kg. A NIR imaging system was used to identify the disseminated tumors. The disseminated nodules in mice were detected without any difficulties. Disseminated tumor nodules were collected from mice with or without injections of liposomal formulation and were transferred into the swine peritoneal cavity. The nodules in the swine peritoneal cavity were clearly and promptly defined by the NIR imaging system. NIR-fluorescing liposomal probes can effectively target peritoneal disseminated tumors and can be easily detected by a NIR imaging system. These results warrant future clinical trials of our imaging system and may contribute to a more precise diagnosis and therapeutic approach for gastric cancer patients. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  12. In silico identification of a therapeutic target for photo-activated disinfection with indocyanine green: Modeling and virtual screening analysis of Arg-gingipain from Porphyromonas gingivalis.

    Science.gov (United States)

    Pourhajibagher, Maryam; Bahador, Abbas

    2017-06-01

    Porphyromonas gingivalis is a momentous bacterial etiological agent associated with periodontitis, peri-implantitis as well as endodontic infections. The potential advantage of Photo-activated disinfection (PAD) as a promising novel approach is the choice of a suitable target site, specific photosensitizer, and wavelength of light for delivery of the light from source to target. Since Arg-gingipain is a cysteine proteinase that is involved in the virulence of P. gingivalis, it was evaluated as a target site for PAD with indocyanine green (ICG) as a photosensitizer. In this study, we used a range of in silico strategies, bioinformatics tools, biological databases, and computer simulation molecular modeling to evaluate the capacity of Arg-gingipain. The predicted structure of Arg-gingipain indicated that it is located outside the cell and has nine domains and 17 ligands, including two calcium ions and three sodium ions with positive charges which can be a site of interaction for anionic ICG. Based on the results of this study, anionic ICG desires to bind and interact with residues of Arg-gingipain during PAD as a main site to enhance the yield of treatment of endo-periodontal lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Flash fluorescence with indocyanine green videoangiography to identify the recipient artery for bypass with distal middle cerebral artery aneurysms: operative technique.

    Science.gov (United States)

    Rodríguez-Hernández, Ana; Lawton, Michael T

    2012-06-01

    Distal middle cerebral artery (MCA) aneurysms frequently have nonsaccular morphology that necessitates trapping and bypass. Bypasses can be difficult because efferent arteries lie deep in the opercular cleft and may not be easily identifiable. We introduce the "flash fluorescence" technique, which uses videoangiography with indocyanine green (ICG) dye to identify an appropriate recipient artery on the cortical surface for the bypass, enabling a more superficial and easier anastomosis. Flash fluorescence requires 3 steps: (1) temporary clip occlusion of the involved afferent artery; (2) videoangiography demonstrating fluorescence in uninvolved arteries on the cortical surface; and (3) removal of the temporary clip with flash fluorescence in the involved efferent arteries on the cortical surface, thereby identifying a recipient. Alternatively, temporary clips can occlude uninvolved arteries, and videoangiography will demonstrate initial fluorescence in efferent arteries during temporary occlusion and flash fluorescence in uninvolved arteries during reperfusion. From a consecutive series of 604 MCA aneurysms treated microsurgically, 22 (3.6%) were distal aneurysms and 11 required a bypass. The flash fluorescence technique was used in 3 patients to select the recipient artery for 2 superficial temporal artery-to-MCA bypasses and 1 MCA-MCA bypass. The correct recipient was selected in all cases. The flash fluorescence technique provides quick, reliable localization of an appropriate recipient artery for bypass when revascularization is needed for a distal MCA aneurysm. This technique eliminates the need for extensive dissection of the efferent artery and enables a superficial recipient site that makes the anastomosis safer, faster, and less demanding.

  14. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  15. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green-Labeled Podoplanin Antibody.

    Science.gov (United States)

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.

  16. Impact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Tamer Tandogan

    2016-01-01

    Full Text Available Purpose. To investigate the role of indocyanine green (ICG dye as a causative material of toxic anterior segment syndrome (TASS in an experimental rabbit model. Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%, exposure times (10 and 60 seconds, and the degree of dissolution (differently vortexed were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2 Parameter Assay, R&D systems, Inc., and scanning electron microscopy of each iris. Result. There was no reaction in the control eye. A higher aqueous level of PGE2 and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles. Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.

  17. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Cheung, Tan To; Chan, See Ching; Chok, Kenneth S H; Chan, Albert C Y; Yu, Wan Ching; Poon, Ronnie T P; Lo, Chung Mau; Fan, Sheung Tat

    2012-06-01

    The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly-developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON(®), one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16XICGR15(L)+2.73. The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.

  18. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis.

    Science.gov (United States)

    Pind, Marie-Louise L; Bendtsen, Flemming; Kallemose, Thomas; Møller, Søren

    2016-08-01

    Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands expert skills of the staff.In the present study, we aimed to investigate the relationship between the constant infusion indocyanine green (ICG) clearance, the calculated ICG retention test after 15 min (ICG-r15), and HVPG in patients with different severity of cirrhosis for validation of ICG-r15 as a noninvasive predictor of portal hypertension. A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. Assessment of the diagnostic performance of ICG clearance and ICG-r15 as predictors of HVPG above 10 mmHg was performed by receiver operating characteristic curve analyses.The ICG clearance and ICG-r15 performed well in all three Child classes, with the most significant results among Child class A patients [area under the receiver operating characteristic (AUROC)=0.832] and less significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15 may be suitable as a screening tool for the identification of patients for endoscopy and measurement of HVPG.Further validation of ICG-r15 together with other predictors of portal hypertension and its clinical use is encouraged.

  19. Comparison between the indocyanine green fluorescence and blue dye methods for sentinel lymph node biopsy using novel fluorescence image-guided resection equipment in different types of hospitals.

    Science.gov (United States)

    He, Kunshan; Chi, Chongwei; Kou, Deqiang; Huang, Wenhe; Wu, Jundong; Wang, Yabing; He, Lifang; Ye, Jinzuo; Mao, Yamin; Zhang, Guo-Jun; Wang, Jiandong; Tian, Jie

    2016-12-01

    Sentinel lymph node biopsy (SLNB) has become a standard of care to detect axillary lymph metastasis in early-stage breast cancer patients with clinically negative axillary lymph nodes. Current SLNB detection modalities comprising a blue dye, a radioactive tracer, or a combination of both have advantages as well as disadvantages. Thus, near-infrared fluorescence imaging using indocyanine green (ICG) has recently been regarded as a novel method that has generated interest for SLNB around the world. However, the lack of appropriate fluorescence imaging systems has hindered further research and wide application of this method. Therefore, we developed novel fluorescence image-guided resection equipment (FIRE) to detect sentinel lymph nodes (SLNs). Moreover, to compare the ICG fluorescence imaging method with the blue dye method and to explore the universal feasibility of the former, a different type of hospital study was conducted. Ninety-nine eligible patients participated in the study at 3 different types of hospitals. After subcutaneous ICG allergy testing, all the patients were subcutaneously injected with methylene blue and ICG into the subareolar area. Consequently, 276 SLNs (range 1-7) were identified in 98 subjects (detection rate: 99%) by using the ICG fluorescence imaging method. In contrast, the blue dye method only identified 202 SLNs (range 1-7) in 91 subjects (detection rate: 91.92%). Besides, the results of the fluorescence imaging method were similar in the 3 hospitals. Our findings indicate the universal feasibility of the ICG fluorescence imaging method for SLNB using the fluorescence image-guided resection equipment in early breast cancer detection. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Smart human serum albumin-indocyanine green nanoparticles generated by programmed assembly for dual-modal imaging-guided cancer synergistic phototherapy.

    Science.gov (United States)

    Sheng, Zonghai; Hu, Dehong; Zheng, Mingbin; Zhao, Pengfei; Liu, Huilong; Gao, Duyang; Gong, Ping; Gao, Guanhui; Zhang, Pengfei; Ma, Yifan; Cai, Lintao

    2014-12-23

    Phototherapy, including photodynamic therapy (PDT) and photothermal therapy (PTT), is a light-activated local treatment modality that is under intensive preclinical and clinical investigations for cancer. To enhance the treatment efficiency of phototherapy and reduce the light-associated side effects, it is highly desirable to improve drug accumulation and precision guided phototherapy for efficient conversion of the absorbed light energy to reactive oxygen species (ROS) and local hyperthermia. In the present study, a programmed assembly strategy was developed for the preparation of human serum albumin (HSA)-indocyanine green (ICG) nanoparticles (HSA-ICG NPs) by intermolecular disulfide conjugations. This study indicated that HSA-ICG NPs had a high accumulation with tumor-to-normal tissue ratio of 36.12±5.12 at 24 h and a long-term retention with more than 7 days in 4T1 tumor-bearing mice, where the tumor and its margin, normal tissue were clearly identified via ICG-based in vivo near-infrared (NIR) fluorescence and photoacoustic dual-modal imaging and spectrum-resolved technology. Meanwhile, HSA-ICG NPs efficiently induced ROS and local hyperthermia simultaneously for synergetic PDT/PTT treatments under a single NIR laser irradiation. After an intravenous injection of HSA-ICG NPs followed by imaging-guided precision phototherapy (808 nm, 0.8 W/cm2 for 5 min), the tumor was completely suppressed, no tumor recurrence and treatments-induced toxicity were observed. The results suggest that HSA-ICG NPs generated by programmed assembly as smart theranostic nanoplatforms are highly potential for imaging-guided cancer phototherapy with PDT/PTT synergistic effects.

  1. Complex microcirculation patterns detected by confocal indocyanine green angiography predict time to growth of small choroidal melanocytic tumors: MuSIC Report II.

    Science.gov (United States)

    Mueller, Arthur J; Freeman, William R; Schaller, Ulrich C; Kampik, Anselm; Folberg, Robert

    2002-12-01

    Multiple independent laboratories have confirmed the histologic observation that some tumor microcirculation patterns (MCPs) in uveal melanomas are associated strongly with death resulting from metastatic disease. Because these patterns are imageable with confocal indocyanine green angiography (ICG), we designed a prospective study to evaluate whether these angiographically detectable MCPs predict time to tumor growth. Observational case series, prospective, non-randomized. Ninety-eight patients with unilateral, small, choroidal melanocytic tumors. The following information and tumor characteristics were recorded for each patient: demographic parameters, best-corrected visual acuity, intraocular pressure, related visual symptoms, location and dimension of tumor, pigmentation, orange pigment, drusen, tumor-associated hemorrhage, subretinal fluid, and confocal ICG angiographically determined microcirculation patterns-silent (avascularity), normal (preexisting normal choroidal vessels within the tumor), straight vessels, parallel without and with cross-linking, arcs without and with branching, loops, and networks. Time to growth of the tumor, with growth defined as an increase in the maximal apical tumor height of 0.5 mm measured by standardized A-scan ultrasonography, photographic documentation of an increase of the largest basal diameter of at least 1.5 mm, advancement of one tumor border of at least 0.75 mm, or a combination thereof. Twenty-eight of the 98 tumors in this study (29%) met the predetermined criteria for tumor growth. The median time to growth was 127 days (range, 51-625 days). The following tumor characteristics were significantly associated with time to tumor growth: flashes (P = 0.0224), orange pigment (P = 0.012), subretinal fluid (P < 0.001), maximum basal tumor diameter at initial examination (P = 0.015), maximum apical tumor height (P < 0.001), parallel with cross-linking MCP (P < 0.001), arcs with branching MCP (P = 0.006), loops (P < 0

  2. Association between pretreatment retention rate of indocyanine green 15 min after administration and life prognosis in patients with HCC treated by proton beam therapy

    International Nuclear Information System (INIS)

    Mizumoto, Masashi; Oshiro, Yoshiko; Okumura, Toshiyuki; Fukuda, Kuniaki; Fukumitsu, Nobuyoshi; Abei, Masato; Ishikawa, Hitoshi; Ohnishi, Kayoko; Numajiri, Haruko; Tsuboi, Koji; Sakurai, Hideyuki

    2014-01-01

    Purpose: The Child-Pugh score is often used to judge the outcome of radiotherapy for hepatocellular carcinoma (HCC). The retention rate of indocyanine green 15 min after administration (ICG R15) can also be used to predict prognosis after liver resection. We evaluated the utility of ICG R15 for prediction of outcomes after proton beam therapy (PBT) for HCC. Methods and materials: A retrospective evaluation was performed in 250 patients who received PBT between 2002 and 2007. The patients (178 males and 72 females) had a median age of 71 years (range: 43–88). Child-Pugh categories were A (score 5–6), B (7–9), and C (10–15) in 197, 51, and 2 patients, respectively. ICG scores were 0–<10, 10–<20, 20–<30, 30–<40 and ⩾40 in 27, 99, 59, 28 and 37 patients, respectively; including 26, 92, 45, 16 and 18 Child-Pugh A patients and 1, 8, 14, 11, and 17 Child-Pugh B patients, respectively. Survival times from the start of PBT were compared between Child-Pugh A and B patients, and among each ICG group. Results: The median survival times were 61 months (95% CI: 50–72 months) in all patients, and 64 and 20 months in Child-Pugh A and B patients, respectively (p = 0.001), The 3-year survival rates were 72%, 72%, 75%, 63%, and 26% in patients with ICG scores of 0–<10, 10–<20, 20–<30, 30–<40, and ⩾40 (p = 0.001); 70%, 75%, 77%, 65%, and 38% in these respective groups in Child-Pugh A patients (p = 0.02); and 100%, 57%, 67%, 36%, and 14% in Child-Pugh B patients (p = 0.173, not significant). Multivariate analysis showed that low ICG R15 and the absence of portal vein tumor thrombus were associated with good survival. Conclusions: Pretreatment ICG R15 is a useful prognostic factor for prediction of outcome of PBT in HCC patients, especially in those with Child-Pugh A liver function

  3. Correlation between HBsAg, prothrombin time activity, and indocyanine green retention rate at 15 minutes in patients with HBeAg-positive chronic HBV infection

    Directory of Open Access Journals (Sweden)

    FAN Wenhai

    2016-11-01

    Full Text Available ObjectiveTo investigate the correlation between HBsAg, prothrombin time activity (PTA, and indocyanine green retention rate at 15 minutes (ICG R15 in patients with HBeAg-positive chronic HBV infection. MethodsA total of 92 patients with HBeAg-positive chronic HBV infection who were admitted to The First Hospital of Lanzhou University from December 2015 to April 2016 were enrolled and divided into chronic hepatitis B (CHB group (24 patients, compensated liver cirrhosis group (38 patients, and decompensated liver cirrhosis group (30 patients. Serum HBsAg quantitation, PTA test, and liver reserve function test (ICG R15 were performed for all patients. The chi-square test was used for comparison of categorical data between groups, an analysis of variance was used for comparison of continuous data between multiple groups, and a Pearson correlation analysis was also performed. ResultsThere were significant differences between the three groups in serum HBsAg quantitation (3.82±0.43 log10IU/ml vs 2.88±0.36 log10IU/ml vs 2.60±0.27 log10IU/ml, F=25.19, P<0.001, ICG R15 (7.51%±3.10% vs 9.57%±8.18% vs 24.13%±14.28%, F=24.00, P=0.001, and PTA (8100%±1762% vs 83.08%±9.64% vs 62.32%±16.90%, F=13.42, P=0.009. The correlation analysis showed that PTA was negatively correlated with ICG R15 in all three groups (r=-0.948, -0.602, and -0.735, all P<0.01. In the compensated liver cirrhosis group and decompensated liver cirrhosis group, HBsAg was positively correlated with PTA (r=0.410 and 0.473, both P<0.05 and negatively correlated with ICG R15 (r=-0.427 and -0.768, P<0.01. ConclusionIn HBeAg positive patients, there are certain correlations between HBsAg, PTA, and ICG R15, which, to a certain degree, reflects the liver reserve function in patients with chronic HBV infection.

  4. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    Science.gov (United States)

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  5. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  6. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  7. Recirculatory modeling in man using Indocyanine green

    NARCIS (Netherlands)

    Reekers, Marije

    2012-01-01

    Titration to effect is the most important action anesthesiologists use to assure adequacy of anesthesia and safeguard their patients from serious side effects. For a proper titration to effect the anesthesiologist takes into consideration the historical response to a given dose to estimate the

  8. Near-infrared intraoperative imaging during resection of an anterior mediastinal soft tissue sarcoma.

    Science.gov (United States)

    Predina, Jarrod D; Newton, Andrew D; Desphande, Charuhas; Singhal, Sunil

    2018-01-01

    Sarcomas are rare malignancies that are generally treated with multimodal therapy protocols incorporating complete local resection, chemotherapy and radiation. Unfortunately, even with this aggressive approach, local recurrences are common. Near-infrared intraoperative imaging is a novel technology that provides real-time visual feedback that can improve identification of disease during resection. The presented study describes utilization of a near-infrared agent (indocyanine green) during resection of an anterior mediastinal sarcoma. Real-time fluorescent feedback provided visual information that helped the surgeon during tumor localization, margin assessment and dissection from mediastinal structures. This rapidly evolving technology may prove useful in patients with primary sarcomas arising from other locations or with other mediastinal neoplasms.

  9. Sympathetic ophthalmia - histopathological correlation with fluorescein and indocyanine green angiography: case report Oftalmia simpática - correlação da histopatologia com a angiografia por fluoresceína e indocianina verde: relato de caso

    Directory of Open Access Journals (Sweden)

    Antônio Marcelo Barbante Casella

    2008-12-01

    Full Text Available This study correlates fluorescein angiography (FA and indocyanine green angiography (ICGA to histopathologic findings in a patient with sympathetic ophtalmia. A male with a perforated trauma in right eye presented after two months a decrease in visual acuity of the left eye. FA and ICGA were performed and the images were correlated with the histopathologic findings of the enucleated eye; FA showed background areas of homogeneous hypofluorescence in the arterial and venous phases, as well as areas of granular progressive hyperfluorescence and leakage from the optic disc. ICGA showed areas of hypofluorescence in the early and intermediate phases of the examination, which persisted until the late phase. During the early phase, there was also diffuse hypofluorescence caused by blockage that allowed observation of areas of partial choroidal circulation. The histopathology of the enucleated right eye showed diffuse choriocapillaris edema and inflammation of the choroids, focal areas of hyperplasia of the retinal pigment epithelium (RPE as well as foci of epithelioid cells located between the choroid and the RPE. Furthermore, lymphocytic infiltration of the episcleral veins and retinal detachment were present. The hyperfluorescence observed on FA was correlated to retinal detachment and optic nerve inflammation. The hypofluorescence noted on FA and ICGA corresponded to the presence of blocking inflammatory cells (Dalen-Fuchs-like nodules and to diffuse choriocapillaris edema.O objetivo deste relato de caso foi correlacionar achados da histopatologia com a angiografia por fluoresceína (AF e por indocianina verde (AIV em um paciente com oftalmia simpática. Após dois meses de trauma perfurante no olho direito, o paciente apresentou baixa acuidade visual no olho esquerdo (OE. A AF do OE mostrou áreas de hipofluorescência homogênea na fase arterial e venosa, áreas de progressiva hiperfluorescência granular e vazamento do disco. A AIV mostrou

  10. Intraoperative electrocorticography

    Directory of Open Access Journals (Sweden)

    Gabriela Alcaraz

    2017-01-01

    Full Text Available Intraoperative electrocorticography (ECoG is the recording of electrophysiological activity from electrodes placed directly on the exposed surface of brain, during surgery for epilepsy and tumor resection. The ECoG is helpful in defining the seizure onset and spread within the cortical surface and delineation of the interface between epileptogenic zones and functional cortex substance of the brain. Intraoperative ECoG is an invasive procedure, it is performed during surgery mostly commonly during awake craniotomy but at times during general anaesthesia. As most anesthetic agents will affect ECoG, they should be minimized or stopped prior to any recording. Activation of intraoperative epileptiform activity may also be required if there are no spontaneous discharges. The appropriate management of the anesthetic during the time of ECoG is critical for its success. There are limitations and some controversies to all the uses of intraoperative ECoG, thus each center will set their own indications, criteria, and protocols.

  11. Intraoperative near-infrared fluorescent imaging during robotic operations.

    Science.gov (United States)

    Macedo, Antonio Luiz de Vasconcellos; Schraibman, Vladimir

    2016-01-01

    The intraoperative identification of certain anatomical structures because they are small or visually occult may be challenging. The development of minimally invasive surgery brought additional difficulties to identify these structures due to the lack of complete tactile sensitivity. A number of different forms of intraoperative mapping have been tried. Recently, the near-infrared fluorescence imaging technology with indocyanine green has been added to robotic platforms. In addition, this technology has been tested in several types of operations, and has advantages such as safety, low cost and good results. Disadvantages are linked to contrast distribution in certain clinical scenarios. The intraoperative near-infrared fluorescent imaging is new and promising addition to robotic surgery. Several reports show the utility of this technology in several different procedures. The ideal dose, time and site for dye injection are not well defined. No high quality evidence-based comparative studies and long-term follow-up outcomes have been published so far. Initial results, however, are good and safe. RESUMO A identificação intraoperatória de certas estruturas anatômicas, por seu tamanho ou por elas serem ocultas à visão, pode ser desafiadora. O desenvolvimento da cirurgia minimamente invasiva trouxe dificuldades adicionais, pela falta da sensibilidade tátil completa. Diversas formas de detecção intraoperatória destas estruturas têm sido tentadas. Recentemente, a tecnologia de fluorescência infravermelha com verde de indocianina foi associada às plataformas robóticas. Além disso, essa tecnologia tem sido testada em uma variedade de cirurgias, e suas vantagens parecem estar ligadas a baixo custo, segurança e bons resultados. As desvantagens estão associadas à má distribuição do contraste em determinados cenários. A imagem intraoperatória por fluorescência infravermelha é uma nova e promissora adição à cirurgia robótica. Diversas séries mostram

  12. Fully integrated high-speed intravascular optical coherence tomography/near-infrared fluorescence structural/molecular imaging in vivo using a clinically available near-infrared fluorescence-emitting indocyanine green to detect inflamed lipid-rich atheromata in coronary-sized vessels.

    Science.gov (United States)

    Lee, Sunki; Lee, Min Woo; Cho, Han Saem; Song, Joon Woo; Nam, Hyeong Soo; Oh, Dong Joo; Park, Kyeongsoon; Oh, Wang-Yuhl; Yoo, Hongki; Kim, Jin Won

    2014-08-01

    Lipid-rich inflamed coronary plaques are prone to rupture. The purpose of this study was to assess lipid-rich inflamed plaques in vivo using fully integrated high-speed optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) molecular imaging with a Food and Drug Administration-approved indocyanine green (ICG). An integrated high-speed intravascular OCT/NIRF imaging catheter and a dual-modal OCT/NIRF system were constructed based on a clinical OCT platform. For imaging lipid-rich inflamed plaques, the Food and Drug Administration-approved NIRF-emitting ICG (2.25 mg/kg) or saline was injected intravenously into rabbit models with experimental atheromata induced by balloon injury and 12- to 14-week high-cholesterol diets. Twenty minutes after injection, in vivo OCT/NIRF imaging of the infrarenal aorta and iliac arteries was acquired only under contrast flushing through catheter (pullback speed up to ≤20 mm/s). NIRF signals were strongly detected in the OCT-visualized atheromata of the ICG-injected rabbits. The in vivo NIRF target-to-background ratio was significantly larger in the ICG-injected rabbits than in the saline-injected controls (Pfluorescence reflectance imaging, which correlated well with the in vivo target-to-background ratios (Pfluorescence microscopy, and histopathology also corroborated the in vivo imaging findings. Integrated OCT/NIRF structural/molecular imaging with a Food and Drug Administration -approved ICG accurately identified lipid-rich inflamed atheromata in coronary-sized vessels. This highly translatable dual-modal imaging approach could enhance our capabilities to detect high-risk coronary plaques. © 2014 American Heart Association, Inc.

  13. The Role of Intraoperative Cerebral Angiography in Transorbital Intracranial Penetrating Trauma: A Case Report and Literature Review.

    Science.gov (United States)

    Riley, Jonathan P; Boucher, Andrew B; Kim, Denise S; Barrow, Daniel L; Reynolds, Matthew R

    2017-01-01

    Transorbital intracranial penetrating trauma with a retained intracranial foreign body is a rare event lacking a widely accepted diagnostic and therapeutic algorithm. Intraoperative catheter angiography (IOA) has been advocated by some authorities to rule out cerebrovascular injury before and/or after removal of the object, but no standard of care currently exists. A 19-year-old man was involved in a construction site accident whereby a framing nail penetrated the left globe, traversed the lateral bony orbit, and terminated in the midtemporal lobe. No hematoma or injury to the middle cerebral arteries (MCAs) was apparent on noncontrast head computed tomography (CT) or CT angiography, respectively. The foreign body was removed in the operating room under direct visualization after a frontotemporal craniotomy without incident. No significant venous or arterial bleeding was encountered. All visualized MCA branches appeared intact. Indocyanine green videoangiography performed immediately after object removal showed adequate filling of the MCA branches. Given these uneventful clinical and radiographic findings, IOA was not performed. Postoperative head CT and CT angiography showed no obvious neurovascular injury. On postoperative day 2, the patient was noted to have an expressive aphasia. Cerebral angiography showed absent antegrade filling of the angular artery with some retrograde perfusion. Magnetic resonance imaging confirmed an ischemic infarction in the midtemporal lobe. The patient's expressive aphasia improved to near baseline during his hospitalization and he made an excellent clinical recovery. In transorbital intracranial penetrating trauma with a retained intracranial object, we advocate microsurgical removal of the object under direct visualization followed immediately by IOA. IOA should be strongly considered even in the setting of minimal intraoperative bleeding and normal findings on videoangiography (a course of action that was not followed in the

  14. green

    Directory of Open Access Journals (Sweden)

    Elena Grigoryeva

    2011-02-01

    Full Text Available The “green” topic follows the “youngsters”, which is quite natural for the Russian language.Traditionally these words put together sound slightly derogatory. However, “green” also means fresh, new and healthy.For Russia, and for Siberia in particular, “green” architecture does sound new and fresh. Forced by the anxious reality, we are addressing this topic intentionally. The ecological crisis, growing energy prices, water, air and food deficits… Alexander Rappaport, our regular author, writes: “ It has been tolerable until a certain time, but under transition to the global civilization, as the nature is destroyed, and swellings of megapolises expand incredibly fast, the size and the significance of all these problems may grow a hundredfold”.However, for this very severe Siberian reality the newness of “green” architecture may turn out to be well-forgotten old. A traditional Siberian house used to be built on principles of saving and environmental friendliness– one could not survive in Siberia otherwise.Probably, in our turbulent times, it is high time to fasten “green belts”. But we should keep from enthusiastic sticking of popular green labels or repainting of signboards into green color. We should avoid being drowned in paper formalities under “green” slogans. And we should prevent the Earth from turning into the planet “Kin-dza-dza”.

  15. Monomer adsorption of indocyanine green to gold nanoparticles

    NARCIS (Netherlands)

    Guerrini, Luca; Hartsuiker, Liesbeth; Manohar, Srirang; Otto, Cornelis

    2011-01-01

    NIR-dye encoded gold nanoparticles (GNP) are rapidly emerging as contrast agents in many bio-imaging/sensing applications. The coding process is usually carried out without control or a clear understanding of the metal–liquid interface properties which, in contrast, are critical in determining the

  16. Intraoperative angiography provides objective assessment of skin perfusion in complex knee reconstruction.

    Science.gov (United States)

    Wyles, Cody C; Taunton, Michael J; Jacobson, Steven R; Tran, Nho V; Sierra, Rafael J; Trousdale, Robert T

    2015-01-01

    Wound necrosis is a potentially devastating complication of complex knee reconstruction. Laser-assisted indocyanine green angiography (LA-ICGA) is a technology that has been described in the plastic surgery literature to provide an objective assessment of skin perfusion in the operating room. This novel technology uses a plasma protein bound dye (ICG) and a camera unit that is calibrated to view the frequency emitted by the dye. The intention of this technology is to offer real-time visualization of blood flow to skin and soft tissue in a way that might help surgeons make decisions about closure or coverage of a surgical site based on blood flow, potentially avoiding soft tissue reconstruction while preventing skin necrosis or wound breakdown after primary closures, but its efficacy is untested in the setting of complex TKA. The purpose of this study was to evaluate perfusion borders and tension ischemia in a series of complex knee reconstructions to guide optimal wound management. Beginning in mid-2011, an LA-ICGA system was used to evaluate soft tissue viability in knee reconstruction procedures that were considered high risk for wound complications. Seven patients undergoing complex primary or revision TKA from 2011 to 2013 were included. These patients were chosen as a convenience sample of knee reconstruction procedures for which we obtained consultation with the plastic surgery service. The perfusion of skin and soft tissue coverage was evaluated intraoperatively for all patients with the LA-ICGA system, and the information was used to guide wound management. Followup was at a mean of 9 months (range, 6-17 months), no patients were lost to followup, and the main study endpoint was uneventful healing of the surgical incision. All seven closures went on to heal without necrosis. One patient, however, was subsequently revised for a deep periprosthetic infection 4 months after their knee reconstruction and underwent flap coverage at the time of that revision

  17. Intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Dobelbower Junior, R.R.

    1987-01-01

    A briefly history of intraoperative radiotherapy is presented. The equipment used is described and the treatment with superficial X-ray beams, orthovoltage X-ray beams and megavoltage electron beams are discussed. The effect on normal tissues and the clinical use of intraoperative radiotherapy in several Kind of cancer is studied. (M.A.C.) [pt

  18. [Intraoperative multidimensional visualization].

    Science.gov (United States)

    Sperling, J; Kauffels, A; Grade, M; Alves, F; Kühn, P; Ghadimi, B M

    2016-12-01

    Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.

  19. A surgical navigation system for non-contact diffuse optical tomography and intraoperative cone-beam CT

    Science.gov (United States)

    Daly, Michael J.; Muhanna, Nidal; Chan, Harley; Wilson, Brian C.; Irish, Jonathan C.; Jaffray, David A.

    2014-02-01

    A freehand, non-contact diffuse optical tomography (DOT) system has been developed for multimodal imaging with intraoperative cone-beam CT (CBCT) during minimally-invasive cancer surgery. The DOT system is configured for near-infrared fluorescence imaging with indocyanine green (ICG) using a collimated 780 nm laser diode and a nearinfrared CCD camera (PCO Pixelfly USB). Depending on the intended surgical application, the camera is coupled to either a rigid 10 mm diameter endoscope (Karl Storz) or a 25 mm focal length lens (Edmund Optics). A prototype flatpanel CBCT C-Arm (Siemens Healthcare) acquires low-dose 3D images with sub-mm spatial resolution. A 3D mesh is extracted from CBCT for finite-element DOT implementation in NIRFAST (Dartmouth College), with the capability for soft/hard imaging priors (e.g., segmented lymph nodes). A stereoscopic optical camera (NDI Polaris) provides real-time 6D localization of reflective spheres mounted to the laser and camera. Camera calibration combined with tracking data is used to estimate intrinsic (focal length, principal point, non-linear distortion) and extrinsic (translation, rotation) lens parameters. Source/detector boundary data is computed from the tracked laser/camera positions using radiometry models. Target registration errors (TRE) between real and projected boundary points are ~1-2 mm for typical acquisition geometries. Pre-clinical studies using tissue phantoms are presented to characterize 3D imaging performance. This translational research system is under investigation for clinical applications in head-and-neck surgery including oral cavity tumour resection, lymph node mapping, and free-flap perforator assessment.

  20. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  1. Intraoperative ultrasound in neurosurgery

    International Nuclear Information System (INIS)

    Velasco, J.; Manzanares, R.; Fernandez, L.; Hernando, A.; Ramos, M. del Mar; Garcia, R.

    1996-01-01

    The present work is a review of the major indications for intraoperative ultrasound in the field of neurosurgery, stressing the exploratory method and describing what we consider to be the most illustrative cases. We attempt to provide a thorough view of this constantly developing technique which, despite its great practical usefulness, may be being underemployed. (Author) 47 refs

  2. [Intraoperative floppy iris syndrome].

    Science.gov (United States)

    Mazal, Z

    2007-04-01

    In the year 2005, Chang and Cambell described unusual reaction of the iris during the cataract surgery in patients treated with tamsulosine. This was named as IFIS, an acronym for the Intraoperative Floppy Iris Syndrome. In its advanced stage, the syndrome is characterized by insufficient mydfiasis before the surgery, narrowing of the pupil during the surgery, its impossible dilatation during the surgery by means of stretching, unusual elasticity of the pupilar margin, surging and fluttering iris with tendency to prolapse. The same manifestations we observed in our patients and we confirm the direct connection with tamsulosine hydrochloride treatment. Tamsulosine is the antagonist of alpha 1A adrenergic receptors whose are present, except in the smooth musculature of the prostate gland and the urinary bladder, in the iris dilator as well. At the same time we observed this syndrome rarely in some patients not using tamsulosine. In most cases, these patients were treated with antipsychotic drugs.

  3. Solvent effect on indocyanine dyes: A computational approach

    International Nuclear Information System (INIS)

    Bertolino, Chiara A.; Ferrari, Anna M.; Barolo, Claudia; Viscardi, Guido; Caputo, Giuseppe; Coluccia, Salvatore

    2006-01-01

    The solvatochromic behaviour of a series of indocyanine dyes (Dyes I-VIII) was investigated by quantum chemical calculations. The effect of the polymethine chain length and of the indolenine structure has been satisfactorily reproduced by semiempirical Pariser-Parr-Pople (PPP) calculations. The solvatochromism of 3,3,3',3'-tetramethyl-N,N'-diethylindocarbocyanine iodide (Dye I) has been deeply investigated within the ab initio time-dependent density functional theory (TD-DFT) approach. Dye I undergoes non-polar solvation and a linear correlation has been individuated between absorption shifts and refractive index. Computed absorption λ max and oscillator strengths obtained by TD-DFT are in good agreement with the experimental data

  4. Organic Alternatives to Quantum Dots for Intraoperative Near-Infrared Fluorescent Sentinel Lymph Node Mapping

    Directory of Open Access Journals (Sweden)

    Shunsuke Ohnishi

    2005-07-01

    Full Text Available Intraoperative near-infrared (NIR fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs for sentinel lymph node (SLN mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800, emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.

  5. Targeted intraoperative radiotherapy in oncology

    CERN Document Server

    Keshtgar, Mohammed; Wenz, Frederik

    2014-01-01

    Targeted intraoperative radiotherapy is a major advance in the management of cancer patients. With an emphasis on practical aspects, this book offers an ideal introduction to this innovative  technology for clinicians.

  6. Intraoperative transfusion practices in Europe

    DEFF Research Database (Denmark)

    Meier, J; Filipescu, D; Kozek-Langenecker, S

    2016-01-01

    BACKGROUND: Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (p......RBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. METHODS: We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month...... period in 2013. RESULTS: The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone...

  7. Intraoperative radiotherapy - Current status

    International Nuclear Information System (INIS)

    Gunderson, Leonard L.; Willett, Christopher G.; Harrison, Louis B.

    1997-01-01

    Purpose/Objective: Intraoperative irradiation (IORT) in its broadest sense refers to the delivery of irradiation at the time of an operation. This refresher course will discuss the use of both electrons (IOERT) and high dose rate brachytherapy (IOHDR) in conjunction with surgical exploration and resection ± external irradiation/chemotherapy. Both IORT methods have evolved with similar philosophies as an attempt to achieve higher effective doses of irradiation while dose limiting structures are surgically displaced. The rationale for each is supported by excellent local control ± survival results achieved with brachytherapy alone or as a boost to external irradiation in organ preservation efforts in traditional sites (head and neck, breast, gynecologic) wherein a boost dose could be delivered to smaller volumes than could usually be accomplished with external irradiation alone. IOERT has been a tool in modern radiotherapy in Japan since the 1960's and in the U.S. since the mid 1970's. Results from randomized and nonrandomized trials will be presented in the refresher course with major emphasis on GI sites (gastric, pancreas, colorectal) since the data is more mature. While the largest clinical experience with IOERT (± external irradiation/chemotherapy, maximal resection) has been with gastrointestinal cancers in adults, moderate experience has also been obtained with locally advanced retroperitoneal sarcomas and recurrent genitourinary and gynecologic cancers. With primary colorectal cancers that are unresectable for cure or for locally recurrent colorectal cancers, both local control and long-term survival appear to be improved with the aggressive combinations including IOERT when compared to results achieved with conventional treatment. When residual disease exists after resection of gastric cancers, IOERT ± external radiation has achieved optimistic survival results in trials in Japan, the U.S., Spain and China. With locally unresectable pancreatic cancer, an

  8. Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent

    OpenAIRE

    Yang, Changhuei; McGuckin, Laura E. L.; Simon, John D.; Choma, Michael A.; Applegate, Brian E.; Izatt, Joseph A.

    2004-01-01

    We report a new molecular contrast optical coherence tomography (MCOCT) implementation that profiles the contrast agent distribution in a sample by measuring the agent's spectral differential absorption. The method, spectra triangulation MCOCT, can effectively suppress contributions from spectrally dependent scatterings from the sample without a priori knowledge of the scattering properties. We demonstrate molecular imaging with this new MCOCT modality by mapping the distribution of indocyani...

  9. Enhanced visualization of the bile duct via parallel white light and indocyanine green fluorescence laparoscopic imaging

    Science.gov (United States)

    Demos, Stavros G.; Urayama, Shiro

    2014-03-01

    Despite best efforts, bile duct injury during laparoscopic cholecystectomy is a major potential complication. Precise detection method of extrahepatic bile duct during laparoscopic procedures would minimize the risk of injury. Towards this goal, we have developed a compact imaging instrumentation designed to enable simultaneous acquisition of conventional white color and NIR fluorescence endoscopic/laparoscopic imaging using ICG as contrast agent. The capabilities of this system, which offers optimized sensitivity and functionality, are demonstrated for the detection of the bile duct in an animal model. This design could also provide a low-cost real-time surgical navigation capability to enhance the efficacy of a variety of other image-guided minimally invasive procedures.

  10. Intraoperative ultrasound in colorectal surgery.

    Science.gov (United States)

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  11. Metaphysical green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    to adapt to urban environment. It explores the potential of Sensation of Green in the city. The paper questions whether the Sensation of Green could introduce a new spectrum of greens, beside the real green. It develops the term of metaphysical green – does green have to be green or can it be only...

  12. Green(ing) infrastructure

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2014-03-01

    Full Text Available the generation of electricity from renewable sources such as wind, water and solar. Grey infrastructure – In the context of storm water management, grey infrastructure can be thought of as the hard, engineered systems to capture and convey runoff..., pumps, and treatment plants.  Green infrastructure reduces energy demand by reducing the need to collect and transport storm water to a suitable discharge location. In addition, green infrastructure such as green roofs, street trees and increased...

  13. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  14. Towards green loyalty: the influences of green perceived risk, green image, green trust and green satisfaction

    Science.gov (United States)

    Chrisjatmiko, K.

    2018-01-01

    The paper aims to present a comprehensive framework for the influences of green perceived risk, green image, green trust and green satisfaction to green loyalty. The paper also seeks to account explicitly for the differences in green perceived risk, green image, green trust, green satisfaction and green loyalty found among green products customers. Data were obtained from 155 green products customers. Structural equation modeling was used in order to test the proposed hypotheses. The findings show that green image, green trust and green satisfaction has positive effects to green loyalty. But green perceived risk has negative effects to green image, green trust and green satisfaction. However, green perceived risk, green image, green trust and green satisfaction also seems to be a good device to gain green products customers from competitors. The contributions of the paper are, firstly, a more complete framework of the influences of green perceived risk, green image, green trust and green satisfaction to green loyalty analyses simultaneously. Secondly, the study allows a direct comparison of the difference in green perceived risk, green image, green trust, green satisfaction and green loyalty between green products customers.

  15. Minimalism through intraoperative functional mapping.

    Science.gov (United States)

    Berger, M S

    1996-01-01

    Intraoperative stimulation mapping may be used to avoid unnecessary risk to functional regions subserving language and sensori-motor pathways. Based on the data presented here, language localization is variable in the entire population, with only certainty existing for the inferior frontal region responsible for motor speech. Anatomical landmarks such as the anterior temporal tip for temporal lobe language sites and the posterior aspect of the lateral sphenoid wing for the frontal lobe language zones are unreliable in avoiding postoperative aphasias. Thus, individual mapping to identify essential language sites has the greatest likelihood of avoiding permanent deficits in naming, reading, and motor speech. In a similar approach, motor and sensory pathways from the cortex and underlying white matter may be reliably stimulated and mapped in both awake and asleep patients. Although these techniques require an additional operative time and equipment nominally priced, the result is often gratifying, as postoperative morbidity has been greatly reduced in the process of incorporating these surgical strategies. The patients quality of life is improved in terms of seizure control, with or without antiepileptic drugs. This avoids having to perform a second costly operative procedure, which is routinely done when extraoperative stimulation and recording is done via subdural grids. In addition, an aggressive tumor resection at the initial operation lengthens the time to tumor recurrence and often obviates the need for a subsequent reoperation. Thus, intraoperative functional mapping may be best alluded to as a surgical technique that results in "minimalism in the long term".

  16. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  17. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  18. Intraoperative radiotherapy in breast cancer: literature review

    International Nuclear Information System (INIS)

    Alfaro Hidalgo, Sabrina A.

    2013-01-01

    A literature review was performed on intraoperative radiotherapy of breast cancer. The strength and attractiveness is established of techniques of partial irradiation in the treatment of breast cancer. The benefit is originated to restrict the area immediate of radiotherapy to the tumor bed or quadrant index and identifying the benefit of being applied during the radiotherapy while surgical lumpectomy. The impact of local recurrence has been established using intraoperative radiotherapy. The advantages of intraoperative radiotherapy was compared in the management of the conservative surgery in early stages of breast cancer with external radiotherapy. Different methods of intraoperative radiotherapy have been compared and individual impact on local recurrence ranges. Intraoperative radiotherapy has had many advantages: radiobiological, technical, clinical, psychological and economical in the handling of conservative surgery in early stages of breast cancer, compared with external radiotherapy [es

  19. Intraoperative radiotherapy for pancreatic carcinoma

    International Nuclear Information System (INIS)

    Nishimura, Akira; Iida, Koyo; Sato, Shigehiro; Sakata, Suo

    1986-01-01

    Twenty-eight patients with pancreatic carcinoma, 23 (82 %) of whom had Stage III or IV, received intraoperative radiotherapy (IOR) with curative or non-curative surgery. Electron beams (10 to 18 MeV) with doses of 20 to 40 Gy were delivered to the tumor. Eight of 26 patients with unresectable tumor had postoperative external irradiation of 10.5 to 50 Gy. Abdominal and back pain relief was achieved after IOR in 12 (71 %) and in 6 (60 %) of the 26 patients, respectively. Appetite was promoted in 11 patients. In the case of unresectable carcinoma, survival time tended to prolong in the 8 patients receiving both IOR and postoperative external irradiation. One patient developed perforation of the colon probably caused by IOR. (Namekawa, K.)

  20. Practicality of intraoperative teamwork assessments.

    Science.gov (United States)

    Phitayakorn, Roy; Minehart, Rebecca; Pian-Smith, May C M; Hemingway, Maureen W; Milosh-Zinkus, Tanya; Oriol-Morway, Danika; Petrusa, Emil

    2014-07-01

    High-quality teamwork among operating room (OR) professionals is a key to efficient and safe practice. Quantification of teamwork facilitates feedback, assessment, and improvement. Several valid and reliable instruments are available for assessing separate OR disciplines and teams. We sought to determine the most feasible approach for routine documentation of teamwork in in-situ OR simulations. We compared rater agreement, hypothetical training costs, and feasibility ratings from five clinicians and two nonclinicians with instruments for assessment of separate OR groups and teams. Five teams of anesthesia or surgery residents and OR nurses (RN) or surgical technicians were videotaped in simulations of an epigastric hernia repair where the patient develops malignant hyperthermia. Two anesthesiologists, one OR clinical RN specialist, one educational psychologist, one simulation specialist, and one general surgeon discussed and then independently completed Anesthesiologists' Non-Technical Skills, Non-Technical Skills for Surgeons, Scrub Practitioners' List of Intraoperative Non-Technical Skills, and Observational Teamwork Assessment for Surgery forms to rate nontechnical performance of anesthesiologists, surgeons, nurses, technicians, and the whole team. Intraclass correlations of agreement ranged from 0.17-0.85. Clinicians' agreements were not different from nonclinicians'. Published rater training was 4 h for Anesthesiologists' Non-Technical Skills and Scrub Practitioners' List of Intraoperative Non-Technical Skills, 2.5 h for Non-Technical Skills for Surgeons, and 15.5 h for Observational Teamwork Assessment for Surgery. Estimated costs to train one rater to use all instruments ranged from $442 for a simulation specialist to $6006 for a general surgeon. Additional training is needed to achieve higher levels of agreement; however, costs may be prohibitive. The most cost-effective model for real-time OR teamwork assessment may be to use a simulation technician

  1. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Intraoperative radiotherapy for adenocarcinoma of the pancreas

    International Nuclear Information System (INIS)

    Yasue, Mitsunori; Yasui, Kenzo; Morimoto, Takeshi; Miyaishi, Seiichi; Morita, Kozo

    1986-01-01

    Thirty-six patients were given intraoperative radiotherapy for adenocarcinoma of the pancreas between April 1980 and March 1986. Twenty-six of those with well-advanced cancer underwent palliative intraoperative radiotherapy of their main primary lesions (1,500 to 3,000 rads). Fourteen of the 19 patients in this group who had intractable back pain before surgery achieved relief within one week after treatment. Of the remaining 10 patients who underwent pancreatectomy and received adjuvant intraoperative radiotherapy (2,000 to 3,000 rads), two remain clinically free of disease five years and six months and four years and six months after palliative distal pancreatectomy. (author)

  3. Intraoperative Radiotherapy for Breast Cancer

    Directory of Open Access Journals (Sweden)

    Eleanor E. R. Harris

    2017-12-01

    Full Text Available Intraoperative radiotherapy (IORT for early stage breast cancer is a technique for partial breast irradiation. There are several technologies in clinical use to perform breast IORT. Regardless of technique, IORT generally refers to the delivery of a single dose of radiation to the periphery of the tumor bed in the immediate intraoperative time frame, although some protocols have performed IORT as a second procedure. There are two large prospective randomized trials establishing the safety and efficacy of breast IORT in early stage breast cancer patients with sufficient follow-up time on thousands of women. The advantages of IORT for partial breast irradiation include: direct visualization of the target tissue ensuring treatment of the high-risk tissue and eliminating the risk of marginal miss; the use of a single dose coordinated with the necessary surgical excision thereby reducing omission of radiation and the selection of mastectomy for women without access to a radiotherapy facility or unable to undergo several weeks of daily radiation; favorable toxicity profiles; patient convenience and cost savings; radiobiological and tumor microenvironment conditions which lead to enhanced tumor control. The main disadvantage of IORT is the lack of final pathologic information on the tumor size, histology, margins, and nodal status. When unexpected findings on final pathology such as positive margins or positive sentinel nodes predict a higher risk of local or regional recurrence, additional whole breast radiation may be indicated, thereby reducing some of the convenience and low-toxicity advantages of sole IORT. However, IORT as a tumor bed boost has also been studied and appears to be safe with acceptable toxicity. IORT has potential efficacy advantages related to overall survival related to reduced cardiopulmonary radiation doses. It may also be very useful in specific situations, such as prior to oncoplastic reconstruction to improve accuracy of

  4. Intraoperative neurophysiological monitoring for the anaesthetist

    African Journals Online (AJOL)

    2012-11-15

    Nov 15, 2012 ... ... nerve tracts, and by understanding how anaesthetic agents affect the various ... of the physiologically sensitive nervous system and different ... Keywords: evoked potentials, intraoperative monitoring, brain mapping. Abstract.

  5. Green Tourism

    OpenAIRE

    Hasan, Ali

    2014-01-01

    Green tourism is defined as environmentally friendly tourism activities with various focuses and meanings. In a broad term, green tourism is about being an environmentally friendly tourist or providing environmentally friendly tourist services. The green tourism concept would be highly appealing to tourism enterprises and operators owing to increasing governmental pressure to improve environmental performance by adopting effective and tangible environmental management techniques. Green to...

  6. Metaphysical green

    OpenAIRE

    Earon, Ofri

    2011-01-01

    “Sensation of Green is about the mental process like touching, seeing, hearing, or smelling, resulting from the immediate stimulation of landscape forms, plants, trees, wind and water. Sensation of Green triggers a feeling of scale, cheerfulness, calmness and peace. The spatial performance of Sensation of Green is created by a physical interaction between the language of space and the language of nature” The notion of Sensation of Green was developed through a previous study ‘Learning from th...

  7. Metaphysical green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    example is a tiny Danish summer house from 1918 . The second example is ‘House before House’ , in Tokyo. The third example is a prefabricated house ‘CHU’ . The analysis evaluates the characteristics of diverse tones of green – from green image to green sensation. The analysis is based on the original...... of Sensation of Green is created by a physical interaction between the language of space and the language of nature” The notion of Sensation of Green was developed through a previous study ‘Learning from the Summer House’ investigating the unique architectural characteristics of the Danish summer houses...... the Sensation of Green? Three existing examples are agents to this discussion. The first example is a Danish summer house. The other two are international urban examples. While the summer house articulates the original meaning of Sensation of Green, the urban examples illustrate its urban context. The first...

  8. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    Science.gov (United States)

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  9. [Selective intraoperative cholangiography in laparoscopic cholecystectomy].

    Science.gov (United States)

    Pickuth, D; Leutloff, U

    1995-01-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments; however, it is controversial. We have developed a new diagnostic strategy for the detection of bile duct stones. The concept is based on an ultrasound examination and on screening for the presence of six risk indicators of choledocholithiasis. A total of 120 patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of these six risk indicators: history of jaundice, history of pancreatitis, hyperbilirubinemia, hyperamylasemia, dilated bile duct, and unclear ultrasound findings. The sensitivity of ultrasound and intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. Twenty percent of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (P concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that routine use of intraoperative cholangiography is not necessary.

  10. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  11. Intraoperative radiotherapy for cancer of the pancreas

    International Nuclear Information System (INIS)

    Manabe, Tadao; Nagai, Toshihiro; Tobe, Takayoshi; Shibamoto, Yuta; Takahashi, Masaharu; Abe, Mitsuyuki

    1985-01-01

    Seven patients treated by intraoperative radiotherapy for cancer of the pancreas were evaluated. Three patients undergoing pancreaticoduodenectomy for cancer of the head of the pancreas received a dose of 2,500--3,000 rad (6--10 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 2,520 rad (10 MeV lineac X-ray). One patient developed radiation pancreatitis and died 0.8 month after surgery. Autopsy revealed the degeneration of cancer cells in the involved superior mesenteric artery. One died of hepatic metastasis 8.5 months after surgery, however, recurrence was not found in the irradiation field. The other patient who had external beam irradiation combined with intraoperative radiotherapy is alive 7.5 months after surgery. Four patients with unresectable cancer of the body of the pancreas received a dose of 2,500--3,000 rad (13--18 MeV Betatron) intraoperatively with or without external beam irradiation at a dose of 1,500--5,520 rad (10 MeV lineac X-ray). One patient died of peritonitis carcinomatosa 3.0 months after surgery. One patient died of DIC 0.6 month after surgery. Two patients are alive 1.0 and 6.5 months after surgery. In these patients with intraoperative radiotherapy for unresectable cancer of the pancreas, remarkable effects on relief of pain and shrinkage of tumor were obtained. Further pursuit of intraoperative and external beam radiotherapies in combination with pancreatectomy should be indicated in an attempt to prolong survival of patient with cancer of the pancreas. (author)

  12. Green Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Collison, Melanie

    2011-05-15

    Green chemistry is the science of chemistry used in a way that will not use or create hazardous substances. Dr. Rui Resendes is working in this field at GreenCentre Canada, an offshoot of PARTEQ Innovations in Kingston, Ontario. GreenCentre's preliminary findings suggest their licensed product {sup S}witchable Solutions{sup ,} featuring 3 classes of solvents and a surfactant, may be useful in bitumen oil sands extraction.

  13. Green roofs

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-04-01

    Full Text Available , beetles and spiders); and the number of birds that nest in vegetated roofs (including kestrels, swallows, and wagtails). Objective The primary objective of a green roof is to create a living habitat in an otherwise barren environment, hence the use... the negative environmental impacts including plant and insect specie loss. Thus at a philosophical level green roofs support the notion “replace what you displace”. Key ecological issues that can be addressed through green roofs include: Negative effects...

  14. Green thunderstorms

    Science.gov (United States)

    Gallagher, Frank Woolsey, III

    Many people around the world have observed green light apparently emanating from severe thunderstorms, but until recently there has been no scientific study of the phenomenon. Green thunderstorms have been observed from time to time in association with deep convection or severe weather events. Some skeptics who have not personally observed a green thunderstorm suggest that they are some kind of illusion. The existence of green thunderstorms has been objectively demonstrated by recording spectra of light from thunderstorms using a handheld spectrophotometer. During the spring and summer of 1995 and the spring of 1996 numerous storms were observed and spectra of the light emanating from these storms were recorded. Observations were made both at the ground and aboard research aircraft. Furthermore, time series of spectra were recorded as the observed color of some storms changed from dark blue to a bluish-green. Several hypotheses have been advanced to explain the occurrence of green light in connection with severe storms. Fankhauser gave some observational support to the belief that green light from thunderstorms is possible and believed that the source of the light is from the blue sky penetrating thin regions in the clouds. Fraser believes that light from the setting sun, in combination with the process of scattering by atmospheric molecules, creates the green light associated with severe weather and the thunderstorm acts only as a black backdrop. Unfortunately, no cloud illuminated by the sun is black and the green airlight produced by the Fraser theory is in reality overwhelmed by light reflected by the cloud. Often the unusual coloration has been attributed to hail or to reflection of light from foliage on the ground. The quantitative measurements made during the observation period fail to support these assumptions. We have observed thunderstorms to be green over ground that was not green and we have observed blue thunderstorms over ground that was green

  15. Behaviorally Green

    DEFF Research Database (Denmark)

    Sunstein, Cass; Reisch, Lucia A.

    2016-01-01

    of suggestion, inertia, and loss aversion. If well-chosen, green defaults are likely to have large effects in reducing the economic and environmental harms associated with various products and activities. Such defaults may or may not be more expensive to consumers. In deciding whether to establish green...

  16. Green Tea

    Science.gov (United States)

    ... and cancer. Green tea is consumed as a beverage. It is also sold in liquid extracts, capsules, and tablets and is sometimes used in topical products (intended to be applied to the skin). How Much Do We Know? Although many studies have been done on green tea and its ...

  17. Intra-operative radiotherapy in oncology

    International Nuclear Information System (INIS)

    Gerard, J.P.; Braillon, G.; Sentenac, I.; Calvo, F.; Dubois, J.B.; Saint-Aubert, B.; Guillemin, C.; Roussel, A.

    1991-01-01

    This article is about a treatment used more and more frequently in the world, for some neoplasms: Intra-operative radiotherapy under electron beams. The main neoplasms concerned by this treatment are the stomach, pancreas, rectum, bladder, uterus cervix neoplasms and peritoneal sarcoma [fr

  18. Intraoperative neurophysiological monitoring for the anaesthetist ...

    African Journals Online (AJOL)

    Intraoperative neurophysiological monitoring (IONM) has become the gold standard for the monitoring of functional nervous tissue and mapping of eloquent brain tissue during neurosurgical procedures. The multimodal use of somatosensory-evoked potentials and motor-evoked potentials ensures adequate monitoring of ...

  19. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  20. Green consumerism

    DEFF Research Database (Denmark)

    de Groot, Judith I.M.; Schuitema, Geertje; Garson, Carrie Lee

    and biospheric values influence the importance of such ‘green’ product characteristics on purchasing intentions. In two within-subjects full-factorial experimental studies (N = 100 and N = 107), we found that purchase intentions of products were only steered by green characteristics if prices were low...... and the brand was familiar. Green product characteristics did not influence purchase intentions at all when these proself product characteristics were not fulfilled (i.e., high prices and unfamiliar brands). The importance of proself and green product characteristics on purchasing intentions was also......Our presentation will focus on the influence of product characteristics and values on green consumerism. Although generally a majority of consumers support the idea of purchasing green products, we argue, based on social dilemma theory, that proself product characteristics and egoistic...

  1. Green lights

    DEFF Research Database (Denmark)

    Fisker, Peter Kielberg

    This study investigates the effect of drought on economic activity globally using remote sensing data. In particular, predicted variation in greenness is correlated with changes in the density of artificial light observed at night on a grid of 0.25 degree latitude-longitude pixels. I define drought...... as greenness estimated by lagged variation in monthly rainfall and temperature. This definition of drought performs well in identifying self-reported drought events since 2000 compared with measures of drought that do not take greenness into account, and the subsequent analysis indicates that predicted...... variation in greenness is positively associated with year-on-year changes in luminosity: If a unit of observation experiences a predicted variation in greenness that lies 1 standard deviation below the global mean, on average 1.5 - 2.5 light pixels out of 900 are extinguished that year. Finally, an attempt...

  2. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR METASTATIC PERITONEAL TUMORS

    Directory of Open Access Journals (Sweden)

    E. A. Suleimanov

    2016-01-01

    Full Text Available This review is devoted to the cytoreductive treatment of malignant tumors of the abdominal organs. The actuality of the issue is determined both by increase of the incidence of abdominal cancer in Russia and in majority of developed countries and by high rate diagnosis on late stages of disease. The methods of treatment of peritoneal carcinomatosis, based on possible effects on the secondary peritoneal tumors after surgical cytoreduction to reduce the risk of local recurrence and disease progression are described. These methods of additional intraoperative specific antitumor action include intraoperative radiation therapy, hyperthermic intraperitoneal chemotherapy, intraoperative photodynamic therapy characterized by differences in difficulty of performance, mechanisms of effect on tumor and healthy tissues, efficiency. Benefits, opportunities and possibilities of application of intraoperative photodynamic therapy (IOPDT for secondary peritoneal tumors are described in details, the results of a number of domestic and foreign clinical studies are shown, the successful application of intraoperative photodynamic therapy in clinical oncology, which allows reducing the risk of secondary tumor lesions of the peritoneum significantly, is demonstrated. Photodynamic therapy – a method with high efficiency and almost no side effects and complications, based on the ability of photosensitizer to accumulate selectively and retain in the high proliferative tissues. The advantages of this type of treatment of patients with peritoneal carcinomatosis are a selective effect on the peritoneal carcinomatosis and on visually detected tumor tissue, high efficiency in patients with malignant tumors of the abdominal cavity and pelvis combined with surgical cytoreduction, minimal effect on normal organs and tissues of the patient, well tolerated procedure.

  3. Intraoperative high-field magnetic resonance imaging, multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas.

    Science.gov (United States)

    Li, Fang-Ye; Chen, Xiao-Lei; Xu, Bai-Nan

    2016-09-01

    To determine the beneficial effects of intraoperative high-field magnetic resonance imaging (MRI), multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas. Twelve patients with 13 supratentorial cavernomas were prospectively enrolled and operated while using a 1.5 T intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. All cavernomas were deeply located in subcortical areas or involved critical areas. Intraoperative high-field MRIs were obtained for the intraoperative "visualization" of surrounding eloquent structures, "brain shift" corrections, and navigational plan updates. All cavernomas were successfully resected with guidance from intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. In 5 cases with supratentorial cavernomas, intraoperative "brain shift" severely deterred locating of the lesions; however, intraoperative MRI facilitated precise locating of these lesions. During long-term (>3 months) follow-up, some or all presenting signs and symptoms improved or resolved in 4 cases, but were unchanged in 7 patients. Intraoperative high-field MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring are helpful in surgeries for the treatment of small deeply seated subcortical cavernomas.

  4. Green Engineering

    Science.gov (United States)

    Green Engineering is the design, commercialization and use of processes and products that are feasible and economical while reducing the generation of pollution at the source and minimizing the risk to human health and the environment.

  5. Green Roofs

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-08-01

    A New Technology Demonstration Publication Green roofs can improve the energy performance of federal buildings, help manage stormwater, reduce airborne emissions, and mitigate the effects of urban heat islands.

  6. Going Green

    Centers for Disease Control (CDC) Podcasts

    This podcast is for a general audience and provides information on how to recycle, re-use, and restore. It also covers the benefits of “Going Green" on the environment, health, and social interaction.

  7. Green lasers

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin

    2010-01-01

    Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range......Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range...

  8. Green Nudging

    OpenAIRE

    Evans, Nicholas; Eickers, Stephanie; Geene, Leonie; Todorovic, Marijana; Villmow, Annika; Forschungsstelle für Umweltpolitik (FFU), Freie Universität Berlin

    2018-01-01

    Traditional environmental policy instruments have not always proven successful in fostering environmentally friendly behaviour. The question remains: how can policymakers tackle the attitude-behaviour gap when it comes to pro-environmental choices and sustainable lifestyles? One solution that has emerged is green nudging, a new and potentially promising policy tool born of behavioural economics and experimental psychology. This paper contributes to the current discussion surrounding green nud...

  9. The Art of Intraoperative Glioma Identification

    Directory of Open Access Journals (Sweden)

    Zoe Z Zhang

    2015-07-01

    Full Text Available A major dilemma in brain tumor surgery is the identification of tumor boundaries to maximize tumor excision and minimize postoperative neurological damage. Gliomas, especially low-grade tumors, and normal brain have a similar color and texture which poses a challenge to the neurosurgeon. Advances in glioma resection techniques combine the experience of the neurosurgeon and various advanced technologies. Intraoperative methods to delineate gliomas from normal tissue consist of 1 image-based navigation, 2 intraoperative sampling, 3 electrophysiological monitoring, and 4 enhanced visual tumor demarcation. The advantages and disadvantages of each technique are discussed. A combination of these methods is becoming widely accepted in routine glioma surgery. Gross total resection in conjunction with radiation, chemotherapy, or immune/gene therapy may increase the rates of cure in this devastating disease.

  10. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  11. Experimental and clinical studies with intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Kinsella, T.; Tepper, J.; Travis, E.L.; Rosenberg, S.A.; Glatstein, E.

    1983-01-01

    Studies of normal tissue tolerance to intraoperative radiotherapy were done upon 65 dogs subjected to laparotomy and 11 million electron volt electron irradiation in doses ranging from zero to 5,000 rads. Results of studies indicated that intact aorta and vena cava tolerate up to 5,000 rads without loss of structural integrity. Ureteral fibrosis and stenosis develop at doses of 3,000 rads or more. Arterial anastomoses heal after doses of 4,500 rads, but fibrosis can lead to occlusion. Intestinal suture lines heal after doses of 4,500 rads. Bile duct fibrosis and stenosis develop at doses of 2,000 rads or more. Biliary-enteric anastomoses fail to heal at any dose level. A clinical trial of intraoperative radiotherapy combined with radical surgery was performed upon 20 patients with advanced malignant tumors which were considered unlikely to be cured by conventional therapies and which included carcinomas of the stomach, carcinomas of the pancreas, carcinomas involving the hilus of the liver, retroperitoneal sarcomas and osteosarcomas of the pelvis. All patients underwent resection of gross tumor, followed by intraoperative irradiation of the tumor bed and regional nodal basins. Some patients received additional postoperative external beam radiotherapy. Treatment mortality for combined operation and radiotherapy occurred in four of 20 patients. Postoperative complications occurred in four of the 16 surviving patients. Local tumor control was achieved in 11 of the 16 surviving patients, with an over-all median follow-up period of 18 months. The clinical trial suggested that intraoperative radiotherapy is a feasible adjunct to resection in locally advanced tumors, that the resulting mortality and morbidity is similar to that expected from operation alone and that local tumor control may be improved

  12. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Büchel, Gabriel E.

    2016-08-03

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Shaffer, Travis M.; Tang, Jun; Austin, Christine; Arora, Manish; Zeglis, Brian M.; Grimm, Jan; Eppinger, Jö rg; Reiner, Thomas

    2016-01-01

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Intraoperative dynamic dosimetry for prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D A [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zaider, M [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Cohen, G N [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Worman, M F [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zelefsky, M J [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States)

    2003-05-07

    This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer - a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications - if necessary - still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

  15. Multispectral open-air intraoperative fluorescence imaging.

    Science.gov (United States)

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  16. Intraoperative lung ultrasound: A clinicodynamic perspective

    Directory of Open Access Journals (Sweden)

    Amit Kumar Mittal

    2016-01-01

    Full Text Available In the era of evidence-based medicine, ultrasonography has emerged as an important and indispensable tool in clinical practice in various specialties including critical care. Lung ultrasound (LUS has a wide potential in various surgical and clinical situations for timely and easy detection of an impending crisis such as pulmonary edema, endobronchial tube migration, pneumothorax, atelectasis, pleural effusion, and various other causes of desaturation before it clinically ensues to critical level. Although ultrasonography is frequently used in nerve blocks, airway handling, and vascular access, LUS for routine intraoperative monitoring and in crisis management still necessitates recognition. After reviewing the various articles regarding the use of LUS in critical care, we found, that LUS can be used in various intraoperative circumstances similar to Intensive Care Unit with some limitations. Except for few attempts in the intraoperative detection of pneumothorax, LUS is hardly used but has wider perspective for routine and crisis management in real-time. If anesthesiologists add LUS in their routine monitoring armamentarium, it can assist to move a step ahead in the dynamic management of critically ill and high-risk patients.

  17. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  18. Green banking

    Directory of Open Access Journals (Sweden)

    Maja Drobnjaković

    2013-06-01

    Full Text Available There is an urgent need to march towards “low - carbon economy”. Global challenges of diminishing fossil fuel reserves, climate change, environmental management and finite natural resources serving an expanding world population - these reasons mean that urgent action is required to transition to solutions which minimize environmental impact and are sustainable. We are at the start of the low - carbon revolution and those that have started on their low - carbon journey already are seeing benefits such as new markets and customers, improved economic, social and environmental performance, and reduced bills and risks. Green investment banks offer alternative financial services: green car loans, energy efficiency mortgages, alternative energy venture capital, eco - savings deposits and green credit cards. These items represent innovative financial products.

  19. Green times

    International Nuclear Information System (INIS)

    Hasenclever, W.D.; Hasenclever, C.

    1982-01-01

    The authors, founding members of the ''Green Party'' have in mind to make a very personal contribution to a better understanding of the present political situation which, although it seems to have reached a deadlock, still offers positive chances and prospects. New approaches in policy are mentioned which may help to overcome the present state of resignation of many adolescents and adults. Among other things, they describe themselves setting out for new pathways, the ''Greens'' in Parliament, prospect for the future, opportunities of the ecologically oriented economic policy. Finally, they call upon the reader to think and develop further under the motto ''What we all can do''. (HSCH) [de

  20. Intraoperative mechanical ventilation: state of the art.

    Science.gov (United States)

    Ball, Lorenzo; Costantino, Federico; Orefice, Giulia; Chandrapatham, Karthikka; Pelosi, Paolo

    2017-10-01

    Mechanical ventilation is a cornerstone of the intraoperative management of the surgical patient and is still mandatory in several surgical procedures. In the last decades, research focused on preventing postoperative pulmonary complications (PPCs), both improving risk stratification through the use of predictive scores and protecting the lung adopting so-called protective ventilation strategies. The aim of this review was to give an up-to-date overview of the currently suggested intraoperative ventilation strategies, along with their pathophysiologic rationale, with a focus on challenging conditions, such as obesity, one-lung ventilation and cardiopulmonary bypass. While anesthesia and mechanical ventilation are becoming increasingly safe practices, the contribution to surgical mortality attributable to postoperative lung injury is not negligible: for these reasons, the prevention of PPCs, including the use of protective mechanical ventilation is mandatory. Mechanical ventilation should be optimized providing an adequate respiratory support while minimizing unwanted negative effects. Due to the high number of surgical procedures performed daily, the impact on patients' health and healthcare costs can be relevant, even when new strategies result in an apparently small improvement of outcome. A protective intraoperative ventilation should include a low tidal volume of 6-8 mL/kg of predicted body weight, plateau pressures ideally below 16 cmH2O, the lowest possible driving pressure, moderate-low PEEP levels except in obese patients, laparoscopy and long surgical procedures that might benefit of a slightly higher PEEP. The work of the anesthesiologist should start with a careful preoperative visit to assess the risk, and a close postoperative monitoring.

  1. Tolerance of retroperitoneal structures to intraoperative radiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.; Terrill, R.

    1982-01-01

    In conjunction with the clinical development of intraoperative radiotherapy, a study was undertaken in dogs to define the tolerance of normal anatomic structures in the retroperitoneum to radiation delivered during operation. Twenty adult dogs were subjected to laparotomy and intraoperative 11 MeV electron irradiation in single doses ranging from 0.to 5000 rad. Animals were followed regularly with clinical observation, blood count, serum chemistries, pyelography, and angiography. Animals were sacrificed and autopsied at regular intervals up to 12 months following treatment to assess radiation-induced complications or tissue damage. Irradiation field in all dogs consisted of a 4 X 15 cm rectangle extending in the retroperitoneum from the level of the renal vessels to the bifurcation of aorta and vena cava. The field included aorta, vena cava, inferior portion of left kidney, and distal portion of left ureter. No complications or histologic changes occurred in any animal given doses of 2000 rad, with a follow-up in excess of 18 months. A dose of 3000 rad was well tolerated, except for left ureteral occlusion in one animal. Mild vascular fibrosis was present inthe aorta and vena cava, and significant ureteral fibrosis developed by six months after doses of 4000 or 5000 rad. All animals that received 5000 rad died of radiation-related complications, including ureteral obstruction and rectal perforation. It was concluded that major vessels tolerate intraoperative irradiation well up to and including 3000 rad and that no clinically significant vascular problems develop after 4000 and 5000 rad, although some fibrosis does occur. The ureter and kidney appear to be the most radiosensitive structures inthe retroperitoneum, showing progressive changes at 300 rad or greater and showing the potential for serious complications after doses of 4000 rad or more

  2. Study on intraoperative radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Uozumi, Akimasa

    1990-01-01

    Effects of a single large dose radiation on the brain of dogs were investigated for the purpose of determining the optimal dose and radiation field in intraoperative radiotherapy. The right parietal lobe of dogs (three groups, four dogs in each) were radiated at the dose of 30, 40 and 50 Gy respectively at the depth of 1.5 cm by 11 Nev electron beam with field size of 2 cm. CT and histopathological study were performed 2, 6, 12 and 24 months after radiation. L-hemiparesis developed 14 months after radiation in the 30 Gy group and 8 months in the 40 Gy group, 6 months in the 50 Gy group. All animals in the 40 Gy and 50 Gy groups died before 15 months of radiation. CT showed delayed radiation necrosis in all groups. Brain swelling and ventricular displacement in the radiated hemisphere and contralateral ventricular dilatation were depicted on plain CT. Diffuse heterogeneous contrast enhancement (CE) was observed on CE-CT. CT revealed disappearance of radiation necrosis in the 30 Gy group 24 months of radiation, suggesting that radiation necrosis may be dependent on the term after radiation. Histological findings of radiation necrosis were similar in all animals, and the vascular change preceding the parechymal necrosis was not observed. This supports the theory that the vascular alternation dose not play a major role in the production of radiation necrosis. The necrotic area grossly reflected the isodose curve and was observed in the radiation field with 15 to 20 Gy at the depth of 3 to 4.5 cm. Thus, the intraoperative radiotherapy should be planned on the basis of two such factors as electron beam energy and the field size, and the area out of the target should not be radiated at the dose of more than 15 Gy. The author believes that the information would contribute to safer and more effective application of intraoperative radiotherapy on malignant brain tumors. (J.P.N.) 63 refs

  3. INTRAOPERATIVE PHOTODYNAMIC THERAPY FOR PERITONEAL MESOTHELIOMA

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2017-01-01

    Full Text Available Abstract Results of application of a new technology of intraoperative photodynamic therapy (IOFDT in patients with peritoneal mesothelioma developed at P. Herzen Moscow Oncology Research Institute are presented. The study included 8 patients. 3 patients underwent surgery in various amount: 1 – limited peritonectomy in the volume of tumor foci resection and resection of a large omentum, 1 – limited peritonectomy in the volume of tumor foci resection and atypical resection of the right lobe of the liver, 1 – only resection of the large omentum due to the fact that the tumor was located only in a large omentum and no signs of lesions of the parietal peritoneum was revealed by intraoperative revision. Surgical intervention in these patients was concluded by IOPDT. The remaining 5 patients underwent only IOPDT. After the treatment, two patients underwent additional courses of laparoscopic IOPDT. Of the 8 patients enrolled in the study, 4 died from the underlying disease, 1 from cardiovascular disease with recurrence of the disease, 1 from cardiovascular disease without signs of recurrence, 2 were monitored for 6 months and 146 months (12 years. Thus, in the group of patients with peritoneal mesothelioma, the maximum observation period was 146.44 months, the median survival was 48.4 months, the total specific 1-year survival was 85.7±13.2%, the three-year survival was 68.5±18.6%, the 5-year survival was 45.7 ± 22.4 %. The average life expectancy after treatment of patients with repeated courses of laparoscopic IOPDT was 87 months, without repeated courses – 35.8 months. Thus, life expectancy was higher in patients with repeated courses of laparoscopic IOPDT. Small sample size caused to the rarity of this pathology does not allow for statistically significant conclusions. However, the results of the study indicate the prospects of multi-course intraoperative photodynamic therapy in patients with peritoneal mesothelioma.

  4. Going Green

    Science.gov (United States)

    Witkowsky, Kathy

    2009-01-01

    Going green saves money and can even make money. Sustainable practices promote better health, less absenteeism, and more productivity. They also attract students, who are paying increasing attention to schools' environmental policies. Beyond being the smart thing to do, administrators at the University of Washington say repeatedly, it's the right…

  5. Buying Green

    Science.gov (United States)

    Layng, T. V. Joe

    2010-01-01

    In "Buying Green," Joe Layng recognizes that, like all choices we make, our decisions as consumers are more likely to be influenced by their short-term consequences for us as individuals (price, quality) than they are by their long-term consequences for society (environmental impact). He believes that the equation can be tilted in favor of greener…

  6. Green pioneers.

    Science.gov (United States)

    Trueland, Jennifer

    The government has set tough targets for the NHS in England to reduce its carbon footprint. In this article, nurses and managers at Nottinghamshire Healthcare NHS Trust explain how a programme of 'greening' initiatives - including a trial of electric cars for community staff - have slashed the trust's CO2 output.

  7. Automatically Green

    DEFF Research Database (Denmark)

    Sunstein, Cass R.; Reisch, Lucia

    2014-01-01

    reasons include the power of suggestion; inertia and procrastination; and loss aversion. If well-chosen, green defaults are likely to have large effects in reducing the economic and environmental harms associated with various products and activities. Such defaults may or may not be more expensive...

  8. Automatically Green

    DEFF Research Database (Denmark)

    Sunstein, Cass R.; Reisch, Lucia

    reasons include the power of suggestion; inertia and procrastination; and loss aversion. If well-chosen, green defaults are likely to have large effects in reducing the economic and environmental harms associated with various products and activities. Such defaults may or may not be more expensive...

  9. Going Green

    Centers for Disease Control (CDC) Podcasts

    2008-04-18

    This podcast is for a general audience and provides information on how to recycle, re-use, and restore. It also covers the benefits of “Going Green" on the environment, health, and social interaction.  Created: 4/18/2008 by National Center for Environmental Health (NCEH), ATSDR.   Date Released: 5/8/2008.

  10. Spinal infection: Evaluation with MR imaging and intraoperative spinal US

    International Nuclear Information System (INIS)

    Donovan Post, M.J.; Montalvo, B.M.; Quencer, R.M.; Katz, B.H.; Green, B.A.; Elsmont, F.

    1987-01-01

    MR spine images and/or intraoperative US scans in 15 patients were reviewed retrospectively and correlated with clinical and pathologic data to determine the diagnostic value of these modalities in spinal infection. In osteomyelitis and retrospinal abscess MR imaging was definitive; in myelitis it was positive but nonspecific. In epidural abscess concomitant with meningitis, myelography with CT and intraoperative US were superior to MR imaging. Intraoperative US could be used to distinguish these processes and to monitor surgical decompression. The authors recommend that MR imaging be performed at the screening examination in cases of spinal infection, accompanied by intraoperative US in all surgical cases

  11. In vivo virtual intraoperative surgical photoacoustic microscopy

    International Nuclear Information System (INIS)

    Han, Seunghoon; Kim, Sehui; Kim, Jeehyun; Lee, Changho; Jeon, Mansik; Kim, Chulhong

    2013-01-01

    We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo

  12. Intraoperative radiation therapy for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Matsutani, Masao; Tanaka, Yoshiaki; Matsuda, Tadayoshi

    1986-01-01

    Intraoperative radiation therapy (IOR) is quite applicable for radioresistant malignant gliomas, because of precise demarcations of the treatment volume under direct vision, minimum damage to surrounding normal tissues, and a high target absorbed dose of 1500 to 2000 rad. Fifteen patients with glioblatoma were treated with IOR, and the 2-year survival rate was 61.1 %. The result apparently indicate that areas adjacent to the margin of almost complete removal should be irradated with a sufficient dose to sterilize the remaining malignant remnants, and IOR is one of the logical treatment modalities for local control of malignant gliomas. (author)

  13. In vivo virtual intraoperative surgical photoacoustic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seunghoon, E-mail: hsh860504@gmail.com; Kim, Sehui, E-mail: sehui0916@nate.com; Kim, Jeehyun, E-mail: jeehk@knu.ac.kr, E-mail: chulhong@postech.edu [School of Electrical Engineering and Computer Science, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Lee, Changho, E-mail: ch31037@postech.edu; Jeon, Mansik, E-mail: msjeon@postech.edu [Department of Creative IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784 (Korea, Republic of); Kim, Chulhong, E-mail: jeehk@knu.ac.kr, E-mail: chulhong@postech.edu [Department of Creative IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784 (Korea, Republic of); Department of Biomedical Engineering, The State University of New York at Buffalo, Buffalo, New York 14221 (United States)

    2013-11-11

    We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo.

  14. Versatile intraoperative MRI in neurosurgery and radiology.

    Science.gov (United States)

    Yrjänä, S K; Katisko, J P; Ojala, R O; Tervonen, O; Schiffbauer, H; Koivukangas, J

    2002-03-01

    Several models for the application of intra-operative magnetic resonance imaging (IMRI) have recently been reported, most of them unique. Two fundamental issues need to be addressed: optimal use of the scanner to ensure a wide base for research, development and clinical application, and an organisational model that facilitates such use. While in our setting the IMRI project was initiated by the neurosurgeons, the need for wider use of the facilities was recognised since the beginning of the planning phase in 1996. An organisational model was developed that allowed for development of neurosurgical applications, radiological imaging, and radiological interventions and for the research and development work of the vendor. A resistive 0.23 T MR scanner was installed in a dedicated operating room environment. Unique to this scanner is the ability to turn off the magnet, allowing for normal OR activities and devices, and to turn on the magnet as needed with a relatively short six-minute ramp up time. A staged surgical technique was perfected, allowing for transfer of data to the neuronavigator outside the scanner during surgery. In neurosurgery, IMRI was used as one part of a neuronavigational system that included ultrasound imaging, intra-operative cortical stimulation during awake procedures, electrocorticography and two neuronavigators. 34 neurosurgical cases included 27 brain tumour resections, 5 brain tumour biopsies, 1 extirpation of an arterio-venous malformation, and 1 haematoma evacuation. The scanner could also be used for normal clinical imaging where obese patients, children, claustophobic patients and postoperative control examinations were the major groups. The radiologists performed 110 interventions, including bone and abdominal biopsies, nerve root infiltrations and local pain therapies, with the optical needle tracking system under continuous MRI guidance. The organisational model allowed frequent use of the facilities for both neurosurgery and radiology

  15. [A Case of Gastric Cancer with Splenic Artery Aneurysm, Intraoperative ICG Fluorography Is Useful in Evaluating the Blood Flow of Stomach and Spleen].

    Science.gov (United States)

    Usui, Kenji; Sakamoto, Kaoru; Akabane, Kentaro; Hayasaka, Kazuki; Mizuki, Toru; Yagi, Yutaka; Shirahata, Yasuhiro; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kameyama, Hitoshi; Suzuki, Satoshi; Saito, Kiyohiro; Wakai, Toshifumi

    2017-11-01

    An 81-year-oldwoman with advancedgastric cancer was referredto our hospital. Preoperative contrast-enhancedCT revealeda roundcalcification of the splenic hilum with 15mm in diameter as a splenic artery aneurysm. She underwent transcatheter arterial embolization(TAE)for the splenic artery aneurysm. Celiac artery angiography showedcollateral arterial network of the spleen from left gastric artery. Surgery for the gastric cancer was performed1 4 days after TAE. We cut the right gastric andbilateral epigastric arteries. After the left gastric artery clamping, we performedintraoperative indocyanine green(ICG)fluorography. ICG fluorography confirmedthat the bloodflow of the upper thirdof the stomach andspleen were maintained. We safely performed distal gastrectomy, and the postoperative course was uneventful.

  16. Brain tumors in eloquent areas: A European multicenter survey of intraoperative mapping techniques, intraoperative seizures occurrence, and antiepileptic drug prophylaxis.

    Science.gov (United States)

    Spena, Giannantonio; Schucht, Philippe; Seidel, Kathleen; Rutten, Geert-Jan; Freyschlag, Christian Franz; D'Agata, Federico; Costi, Emanule; Zappa, Francesca; Fontanella, Marco; Fontaine, Denys; Almairac, Fabien; Cavallo, Michele; De Bonis, Pasquale; Conesa, Gerardo; Foroglou, Nicholas; Gil-Robles, Santiago; Mandonnet, Emanuel; Martino, Juan; Picht, Thomas; Viegas, Catarina; Wager, Michel; Pallud, Johan

    2017-04-01

    Intraoperative mapping and monitoring techniques for eloquent area tumors are routinely used world wide. Very few data are available regarding mapping and monitoring methods and preferences, intraoperative seizures occurrence and perioperative antiepileptic drug management. A questionnaire was sent to 20 European centers with experience in intraoperative mapping or neurophysiological monitoring for the treatment of eloquent area tumors. Fifteen centers returned the completed questionnaires. Data was available on 2098 patients. 863 patients (41.1%) were operated on through awake surgery and intraoperative mapping, while 1235 patients (58.8%) received asleep surgery and intraoperative electrophysiological monitoring or mapping. There was great heterogeneity between centers with some totally AW oriented (up to 100%) and other almost totally ASL oriented (up to 92%) (31% SD). For awake surgery, 79.9% centers preferred an asleep-awake-asleep anesthesia protocol. Only 53.3% of the centers used ECoG or transcutaneous EEG. The incidence of intraoperative seizures varied significantly between centers, ranging from 2.5% to 54% (p mapping technique and the risk of intraoperative seizures. Moreover, history of preoperative seizures can significantly increase the risk of intraoperative seizures (p mapping and monitoring protocols and the management of peri- and intraoperative seizures. This data can help identify specific aspects that need to be investigated in prospective and controlled studies.

  17. Intraoperative MRI in pediatric brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choudhri, Asim F. [Le Bonheur Children' s Hospital, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Ophthalmology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Siddiqui, Adeel [University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Klimo, Paul; Boop, Frederick A. [University of Tennessee Health Science Center, Department of Neurosurgery, Memphis, TN (United States); Le Bonheur Children' s Hospital, Le Bonheur Neuroscience Institute, Memphis, TN (United States); Semmes-Murphey Neurologic and Spine Institute, Memphis, TN (United States); St. Jude Children' s Hospital, Division of Neurosurgery, Department of Surgery, Memphis, TN (United States)

    2015-09-15

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  18. Intraoperative MRI in pediatric brain tumors

    International Nuclear Information System (INIS)

    Choudhri, Asim F.; Siddiqui, Adeel; Klimo, Paul; Boop, Frederick A.

    2015-01-01

    Intraoperative magnetic resonance imaging (iMRI) has emerged as an important tool in guiding the surgical management of children with brain tumors. Recent advances have allowed utilization of high field strength systems, including 3-tesla MRI, resulting in diagnostic-quality scans that can be performed while the child is on the operating table. By providing information about the possible presence of residual tumor, it allows the neurosurgeon to both identify and resect any remaining tumor that is thought to be safely accessible. By fusing the newly obtained images with the surgical guidance software, the images have the added value of aiding in navigation to any residual tumor. This is important because parenchyma often shifts during surgery. It also gives the neurosurgeon insight into whether any immediate postoperative complications have occurred. If any complications have occurred, the child is already in the operating room and precious minutes lost in transport and communications are saved. In this article we review the three main approaches to an iMRI system design. We discuss the possible roles for iMRI during intraoperative planning and provide guidance to help radiologists and neurosurgeons alike in the collaborative management of these children. (orig.)

  19. [Threefold intraoperative electrophysiological monitoring of vestibular neurectomy].

    Science.gov (United States)

    Hausler, R; Kasper, A

    1991-01-01

    A threefold intraoperative monitoring of facial nerve, auditory nerve and vestibular nerve function was performed in 14 cases of retrosigmoidal neurectomy. The facial nerve was monitoring with a pressure transducer placed against the cheek (Opalarm system). The auditory nerve was monitored with acoustically (click) evoked early potentials and the vestibular nerve was monitored with electrically evoked vestibular potentials obtained by direct stimulation (biphasic current pulses of 0.75-mA p-p, 100 us, 20/s) of the exposed vestibular nerve in the cerebellopontine angle before, during and after neurectomy. A characteristic vertex negative peak having a latency of approximately 2 ms and approximately 0.5 uV amplitude was obtained between a forehead and an ipsilateral ear lobe electrode (2 x 1,000 averaged responses over 10 ms) before the neurectomy. This response disappeared after selective vestibular nerve section proximal to the stimulation site. A diminished response amplitude was measured after incomplete nerve section. Simultaneous acoustic masking had no influence on the vestibular potential. The 14 operated patients became all free of vertiginous spells and drop-attacks except one patient who developed a contralateral Menière's. Facial nerve function remained normal in all. Hearing preservation was obtained in 12 patients (86%). The threefold intraoperative monitoring has turned out to be an additional safety factor for facial and auditory nerve preservation and, thanks to the recording of vestibular potentials, it increased the efficiency of vestibular neurectomy.

  20. Intraoperative irradiation in advanced cervical cancer

    International Nuclear Information System (INIS)

    Delgado, G.; Goldson, A.L.; Ashayeri, E.; Petrilli, E.S.

    1987-01-01

    Conventional treatment of cervical cancer, such as radical hysterectomy with lymphadenectomy or pelvic exenteration, is limited to the pelvis. Standard radio-therapeutic treatment is a combination of external-beam radiotherapy to the pelvis and intracavitary applications. However, there is a group of patients for whom external radiotherapy alone has limitations. This group consists primarily of patients with large pelvic lymph nodes containing metastatic cancer, metastatically involved paraaortic lymph nodes outside the usual pelvic radiation field, or large central tumors with parametrial involvement. In patients with cancer of the cervix, the incidence of metastasis to paraaortic lymph nodes is high. Attempts to treat paraaortic nodes with external radiotherapy have resulted in high complication rates because the treatment field includes the highly sensitive gastrointestinal tract. External radiation therapy after retroperitoneal exploration of lymph nodes does not seem to improve survival. In an attempt to circumvent the morbidity and mortality associated with conventional external-beam irradiation, the authors initiated a pilot study of intraoperative electron-beam irradiation of the paraaortic nodes and of the large metastatic lymph nodes in the pelvis. The intraoperative boost was followed by conventional fractionated external-beam irradiation. The theoretical advantages of this procedure include a higher radiation tumor dose without a concomitant increase in treatment morbidity and mortality

  1. Pengaruh Green Marketing Hotel Terhadap Green Consumer Behavior

    OpenAIRE

    Yo Fernandez, Eunike Christe; Tjoanda, Evelyn

    2017-01-01

    Penelitian ini dilakukan untuk mengetahui pengaruh dari green marketing hotel terhadap green consumer behavior. Green marketing memiliki 3 dimensi, yaitu green product, green price, dan green promotion. Penelitian ini melibatkan 272 responden masyarakat Surabaya dan menggunakan metode regresi linear berganda. Hasil penelitian menunjukkan bahwa green product dan green price berpengaruh secara positif dan signifikan sedangkan green promotion berpengaruh namun tidak signifikan terhadap green con...

  2. Green Computing

    Directory of Open Access Journals (Sweden)

    K. Shalini

    2013-01-01

    Full Text Available Green computing is all about using computers in a smarter and eco-friendly way. It is the environmentally responsible use of computers and related resources which includes the implementation of energy-efficient central processing units, servers and peripherals as well as reduced resource consumption and proper disposal of electronic waste .Computers certainly make up a large part of many people lives and traditionally are extremely damaging to the environment. Manufacturers of computer and its parts have been espousing the green cause to help protect environment from computers and electronic waste in any way.Research continues into key areas such as making the use of computers as energy-efficient as Possible, and designing algorithms and systems for efficiency-related computer technologies.

  3. Green toxicology.

    Science.gov (United States)

    Maertens, Alexandra; Anastas, Nicholas; Spencer, Pamela J; Stephens, Martin; Goldberg, Alan; Hartung, Thomas

    2014-01-01

    Historically, early identification and characterization of adverse effects of industrial chemicals was difficult because conventional toxicological test methods did not meet R&D needs for rapid, relatively inexpensive methods amenable to small amounts of test material. The pharmaceutical industry now front-loads toxicity testing, using in silico, in vitro, and less demanding animal tests at earlier stages of product development to identify and anticipate undesirable toxicological effects and optimize product development. The Green Chemistry movement embraces similar ideas for development of less toxic products, safer processes, and less waste and exposure. Further, the concept of benign design suggests ways to consider possible toxicities before the actual synthesis and to apply some structure/activity rules (SAR) and in silico methods. This requires not only scientific development but also a change in corporate culture in which synthetic chemists work with toxicologists. An emerging discipline called Green Toxicology (Anastas, 2012) provides a framework for integrating the principles of toxicology into the enterprise of designing safer chemicals, thereby minimizing potential toxicity as early in production as possible. Green Toxicology`s novel utility lies in driving innovation by moving safety considerations to the earliest stage in a chemical`s lifecycle, i.e., to molecular design. In principle, this field is no different than other subdisciplines of toxicology that endeavor to focus on a specific area - for example, clinical, environmental or forensic toxicology. We use the same principles and tools to evaluate an existing substance or to design a new one. The unique emphasis is in using 21st century toxicology tools as a preventative strategy to "design out" undesired human health and environmental effects, thereby increasing the likelihood of launching a successful, sustainable product. Starting with the formation of a steering group and a series of workshops

  4. Green Gold

    International Nuclear Information System (INIS)

    Salamandra Martinez, Carlos

    2004-01-01

    The main purpose of this work is to offer a general panoramic of the processes or experiences pilot that are carried out in the Project Green Gold, as strategy of environmental sustainability and organizational invigoration in Choco, especially in the 12 communities of the municipalities of Tado and Condoto. It is also sought to offer a minimum of information on the techniques of handmade production and to show the possibilities to carry out in a rational way the use and use of the natural resources. The Project Green Gold is carried out by the Corporation Green Gold (COV) and co-financed with resources of international and national character, the intervention of the financial resources it achievement mainly for the use of clean processes in the extraction stages and metals benefit. The project is centered primarily in the absence of use of products or toxic substances as the mercury, fair trade, organizational invigoration, execution of 11 approaches and certification of the metals Gold and Platinum. The COV, it has come executing the proposal from the year 2001 with the premise of contributing to the balance between the rational exploitation of the natural resources and the conservation of the environment in the Choco. In the project they are used technical handmade characteristic of the region framed inside the mining activity and production activities are diversified in the productive family units. Those producing with the support of entities of juridical character, specify the necessary game rules for the extraction and products commercialization

  5. The Resection Map : A proposal for intraoperative hepatectomy guidance

    NARCIS (Netherlands)

    Lamata, P.; Jalote-Parmar, A.; Lamata, F.; Declerck, J.

    2008-01-01

    Objective - To propose a new concept of an intra-operative 3D visualisation system to support hepatectomies. This system aims at improving the transfer of pre-operative planning into the intra-operative stage, both in laparoscopic and open approaches. Materials and methods - User (surgeon) centred

  6. Greens of the European Green Capitals

    Science.gov (United States)

    Cömertler, Seval

    2017-10-01

    Well established and maintained green areas have a key role on reaching the high quality of life and sustainability in urban environments. Therefore, green areas must be carefully accounted and evaluated in the urban planning affairs. In this context, the European Green Capitals, which attach a great importance to the green areas, have a great potential to act as a role model for both small and big cities in all around the world. These leading cities (chronologically, Stockholm, Hamburg, Vitoria-Gasteiz, Nantes, Copenhagen, Bristol, Ljubljana, Essen and Nijmegen) are inspiring for the other cities which seek to achieve more sustainable and environmentally friendly places through green areas. From this point of view, the aim of this paper was to investigate the green areas of the European Green Capitals. The paper covered whole European Green Capitals, and the application form of each Green Capital was used as a primary data source. Consequently, the paper put forwarded that the European Green Capitals have considerably large amount and high proportion of green areas. Further, these cities provide an excellent access to the public green areas. As a result of abundant provision and proper distribution, the almost all citizens in most of the Green Capitals live within a distance of 300 meters to a green area. For further researches, the paper suggested that these green capitals should be investigated in terms of their efforts, measures, goals and plans, policies and implications to administer, to protect, to enhance and to expand the green areas.

  7. Intraoperative nerve monitoring in laryngotracheal surgery.

    Science.gov (United States)

    Bolufer, Sergio; Coves, María Dolores; Gálvez, Carlos; Villalona, Gustavo Adolfo

    Laryngotracheal surgery has an inherent risk of injury to the recurrent laryngeal nerves (RLN). These complications go from minor dysphonia to even bilateral vocal cord paralysis. The intraoperative neuromonitoring of the RLN was developed in the field of thyroid surgery, in order to preserve nerve and vocal cord function. However, tracheal surgery requires in-field intubation of the distal trachea, which limits the use of nerve monitoring using conventional endotracheal tube with surface electrodes. Given these challenges, we present an alternative method for nerve monitoring during laryngotracheal surgery through the insertion of electrodes within the endolaryngeal musculature by bilateral puncture. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Overview of intraoperative MRI in neurosurgery

    International Nuclear Information System (INIS)

    Shiino, Akihiko; Matsuda, Masayuki

    2002-01-01

    This review describes usefulness, prospect and present problems of intraoperative MRI in neurosurgery. MRI equipments for the surgery have to have a wide, open space and have those magnets of short cylindrical, biplanar (clam shell), dual air core superconducting solenoidal (double doughnut) and targeted FOV (field of view) type. Devices required for the surgery are specific and in author's facility, they are classified into 4 zones depending on the region of their use. Application of the surgery involves biopsy, drainage of cyst and abscess, hematoma evacuation, nerve block, thermotherapy (interstitial laser, RF ablation, focused untrasonic and cryosurgery), local drug therapy, chemoablation, vascular intervention and tumor extraction, of which actual procedures and pictures are presented together with, in particular, MR-guided thermotherapy, ablation therapy of brain tumors, endoscopic surgery and minimally invasive therapy of the spine. A navigation software, 3D SlicerTM system, is introduced for interventional imaging. Safety measures are emphasized for the operation. (K.H.)

  9. Overview of intraoperative MRI in neurosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Shiino, Akihiko; Matsuda, Masayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    2002-01-01

    This review describes usefulness, prospect and present problems of intraoperative MRI in neurosurgery. MRI equipments for the surgery have to have a wide, open space and have those magnets of short cylindrical, biplanar (clam shell), dual air core superconducting solenoidal (double doughnut) and targeted FOV (field of view) type. Devices required for the surgery are specific and in author's facility, they are classified into 4 zones depending on the region of their use. Application of the surgery involves biopsy, drainage of cyst and abscess, hematoma evacuation, nerve block, thermotherapy (interstitial laser, RF ablation, focused untrasonic and cryosurgery), local drug therapy, chemoablation, vascular intervention and tumor extraction, of which actual procedures and pictures are presented together with, in particular, MR-guided thermotherapy, ablation therapy of brain tumors, endoscopic surgery and minimally invasive therapy of the spine. A navigation software, 3D SlicerTM system, is introduced for interventional imaging. Safety measures are emphasized for the operation. (K.H.)

  10. Intraoperative radiotherapy. Clinical experiences and results

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, F.A.; Santos, M. (Clinica Universitaria, Dept. of Oncology, Service of Radiotherapy, Pamplona (Spain)); Brady, L.W. (Hahnemann Univ., Dept. of Radiation Oncology, Philadelphia, PA (United States)) (eds.)

    1992-01-01

    This monograph reports on the largest clinical series to date in which intraoperative radiation therapy (IORT) has been used in mulitdisciplinary treatment programs for tumors of various sites and differing histological sybtype. It represents the product of 5 years' intensive work by physicians active at a leading European institution. The findings are supplemented by a thorough review of the data presented worldwide during the last two decades. The results in this book are meticulously presented and focus on the most important features of clinical research reports based on phase I-II studies (toxicity, local tumor control, and survival data). The tumor sites and histologies analyzed are: head and neck cancer, lung cancer, gastric cancer, pancreatic cancer, colorectal cancer, bladder cancer, gynecologic cancer, soft tissue sarcomas of the extremities, retroperitoneal and other central soft issue sarcomas, Ewing's sarcoma, osteosarcoma, and intracranial tumors. (orig./MG) With 60 figs.

  11. Intra-operative radiation treatment of cancers

    International Nuclear Information System (INIS)

    Dubois, J.B.; Joyeux, H.; Solassol, C.; Pujol, H.

    1986-01-01

    Intra-operative radiation treatment (I.O.R.T.) is concerning the treatment either of an unresectable tumor or of tumor bed after complete excision of a primary tumor and its first draining lymph nodes. We describe X-ray and electrons techniques and we discuss the delivered doses according to experimental and clinical data. According to the residual disease (macroscopic or microscopic), to the healthy tissues in the target volume, and the histological type, single doses from 20 Gy to 40 Gy can be delivered. Our preliminary results are reported: 25 patients with resectable tumors of the cardia, the stomach and the pancreas, 5 patients with pelvic recurrences of colon and rectum carcinomas. Therapeutic results of the I.O.R.T. providing from the literature are discussed. The I.O.R.T. indications are defined as palliative (unresectable tumors) and curative (irradiation of tumor bed after complete excision of the tumor) [fr

  12. Intraoperative radiotherapy for locally advanced refractory cancer

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsuyuki; Takahashi, Masaji; Ono, Koji; Dodo, Yoshihiro; Hiraoka, Masahiro [Kyoto Univ. (Japan). Faculty of Medicine

    1983-05-01

    Clinical results of intraoperative radiotherapy (IOR) in carcinoma of the stomach and prostate, and malignant soft tissue tumors are reported. The 5-year survival rate was found to be increased by IOR in stages II-IV gastric cancer. From the analysis of the clinical results of prostatic cancer, a single dose of 3,500 rad was considered to be a potential curative dose for the tumor less than 3 cm in diameter. The local recurrence rate of patients with malignant soft tissue tumors who received a single dose ranging from 3,000 to 4,500 rad was 5.9 and the 5-year survival rate was 64.6 %.

  13. Brain mapping in tumors: intraoperative or extraoperative?

    Science.gov (United States)

    Duffau, Hugues

    2013-12-01

    In nontumoral epilepsy surgery, the main goal for all preoperative investigation is to first determine the epileptogenic zone, and then to analyze its relation to eloquent cortex, in order to control seizures while avoiding adverse postoperative neurologic outcome. To this end, in addition to neuropsychological assessment, functional neuroimaging and scalp electroencephalography, extraoperative recording, and electrical mapping, especially using subdural strip- or grid-electrodes, has been reported extensively. Nonetheless, in tumoral epilepsy surgery, the rationale is different. Indeed, the first aim is rather to maximize the extent of tumor resection while minimizing postsurgical morbidity, in order to increase the median survival as well as to preserve quality of life. As a consequence, as frequently seen in infiltrating tumors such as gliomas, where these lesions not only grow but also migrate along white matter tracts, the resection should be performed according to functional boundaries both at cortical and subcortical levels. With this in mind, extraoperative mapping by strips/grids is often not sufficient in tumoral surgery, since in essence, it allows study of the cortex but cannot map subcortical pathways. Therefore, intraoperative electrostimulation mapping, especially in awake patients, is more appropriate in tumor surgery, because this technique allows real-time detection of areas crucial for cerebral functions--eloquent cortex and fibers--throughout the resection. In summary, rather than choosing one or the other of different mapping techniques, methodology should be adapted to each pathology, that is, extraoperative mapping in nontumoral epilepsy surgery and intraoperative mapping in tumoral surgery. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.

  14. Best practices to optimize intraoperative photography.

    Science.gov (United States)

    Gaujoux, Sébastien; Ceribelli, Cecilia; Goudard, Geoffrey; Khayat, Antoine; Leconte, Mahaut; Massault, Pierre-Philippe; Balagué, Julie; Dousset, Bertrand

    2016-04-01

    Intraoperative photography is used extensively for communication, research, or teaching. The objective of the present work was to define, using a standardized methodology and literature review, the best technical conditions for intraoperative photography. Using either a smartphone camera, a bridge camera, or a single-lens reflex (SLR) camera, photographs were taken under various standard conditions by a professional photographer. All images were independently assessed blinded to technical conditions to define the best shooting conditions and methods. For better photographs, an SLR camera with manual settings should be used. Photographs should be centered and taken vertically and orthogonal to the surgical field with a linear scale to avoid error in perspective. The shooting distance should be about 75 cm using an 80-100-mm focal lens. Flash should be avoided and scialytic low-powered light should be used without focus. The operative field should be clean, wet surfaces should be avoided, and metal instruments should be hidden to avoid reflections. For SLR camera, International Organization for Standardization speed should be as low as possible, autofocus area selection mode should be on single point AF, shutter speed should be above 1/100 second, and aperture should be as narrow as possible, above f/8. For smartphone, use high dynamic range setting if available, use of flash, digital filter, effect apps, and digital zoom is not recommended. If a few basic technical rules are known and applied, high-quality photographs can be taken by amateur photographers and fit the standards accepted in clinical practice, academic communication, and publications. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Intraoperative radiotherapy in primary rectal cancer; Intraoperative Radiotherapie des primaeren Rektumkarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Mund, Christian

    2013-06-17

    According to the results of several studies intraoperative radiotherapy seems to influence local control for primary rectal cancer in UICC-Stage II / III positively, though recommendations in therapy cannot be given as studies of high evidence level do not exist. As IORT is rarely available and makes patient recruitment difficult, prospective randomised trials have not been carried out yet. This emphasizes the importance of non-randomised trials for an evaluation of IORT. A comparison of 21 patients with locally advanced rectal cancer who had been treated with intraoperative radiation therapy and 21 similar cases without an application of IORT could not show any significant improvements in prognosis (recurrences, metastases and disease-specific survival). Nevertheless the employment of intraoperative radiation showed a trend in improvement of local control. This hast been shown by several other studies before. Thus the application of IORT in patients with locally advanced rectal cancer is considered a useful part in multimodal treatment and should further be evaluated in specialized centres. In case-control studies 1:1-matching leads to a good comparability of groups and renders conclusions of high internal validity possible. To gain a sufficient power, this type of trials should however primarily be carried out by centres with a high number of cases.

  16. Green Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Patten, John

    2013-12-31

    Green Manufacturing Initiative (GMI): The initiative provides a conduit between the university and industry to facilitate cooperative research programs of mutual interest to support green (sustainable) goals and efforts. In addition to the operational savings that greener practices can bring, emerging market demands and governmental regulations are making the move to sustainable manufacturing a necessity for success. The funding supports collaborative activities among universities such as the University of Michigan, Michigan State University and Purdue University and among 40 companies to enhance economic and workforce development and provide the potential of technology transfer. WMU participants in the GMI activities included 20 faculty, over 25 students and many staff from across the College of Engineering and Applied Sciences; the College of Arts and Sciences' departments of Chemistry, Physics, Biology and Geology; the College of Business; the Environmental Research Institute; and the Environmental Studies Program. Many outside organizations also contribute to the GMI's success, including Southwest Michigan First; The Right Place of Grand Rapids, MI; Michigan Department of Environmental Quality; the Michigan Department of Energy, Labor and Economic Growth; and the Michigan Manufacturers Technical Center.

  17. Green chemistry

    International Nuclear Information System (INIS)

    Warner, John C.; Cannon, Amy S.; Dye, Kevin M.

    2004-01-01

    A grand challenge facing government, industry, and academia in the relationship of our technological society to the environment is reinventing the use of materials. To address this challenge, collaboration from an interdisciplinary group of stakeholders will be necessary. Traditionally, the approach to risk management of materials and chemicals has been through inerventions intended to reduce exposure to materials that are hazardous to health and the environment. In 1990, the Pollution Prevention Act encouraged a new tact-elimination of hazards at the source. An emerging approach to this grand challenge seeks to embed the diverse set of environmental perspectives and interests in the everyday practice of the people most responsible for using and creating new materials--chemists. The approach, which has come to be known as Green Chemistry, intends to eliminate intrinsic hazard itself, rather than focusing on reducing risk by minimizing exposure. This chapter addresses the representation of downstream environmental stakeholder interests in the upstream everyday practice that is reinventing chemistry and its material inputs, products, and waste as described in the '12 Principles of Green Chemistry'

  18. Green urbanity

    Directory of Open Access Journals (Sweden)

    Alenka Fikfak

    2012-01-01

    Full Text Available Tourism and other culture-based types of small business, which are the leitmotif in the planning of the Europark Ruardi, are becoming the guiding motif in the spatial development of urban centres that are influenced by dynamic transformation processes. The system should build upon the exploitation of both local and regional environmental features. This would encourage the quest for special environmental features, with an emphasis on their conservation, i.e. sustainable development, and connections in a wider context.The Europark is seen as a new strategic point of the Zasavje Region (the region of the central Sava Valley, which is linked to other important points in a region relevant for tourism. Due to the "smallness" of the region and/or the proximity of such points, development can be fast and effective. The interaction of different activities in space yields endless opportunities for users, who choose their own goals and priorities in the use of space. Four theme areas of the Europark area planning are envisaged. The organisation of activities is based on the composition of the mosaic field patterns, where green fields intertwine with areas of different, existing and new, urban functions. The fields of urban and recreation programmes are connected with a network of green areas and walking trails, along which theme park settings are arranged.

  19. Green shipping management

    CERN Document Server

    Lun, Y H Venus; Wong, Christina W Y; Cheng, T C E

    2016-01-01

    This book presents theory-driven discussion on the link between implementing green shipping practices (GSP) and shipping firm performance. It examines the shipping industry’s challenge of supporting economic growth while enhancing environmental performance. Consisting of nine chapters, the book covers topics such as the conceptualization of green shipping practices (GSPs), measurement scales for evaluating GSP implementation, greening capability, greening and performance relativity (GPR), green management practice, green shipping network, greening capacity, and greening propensity. In view of the increasing quest for environment protection in the shipping sector, this book provides a good reference for firms to understand and evaluate their capability in carrying out green operations on their shipping activities.

  20. From green architecture to architectural green

    DEFF Research Database (Denmark)

    Earon, Ofri

    2011-01-01

    that describes the architectural exclusivity of this particular architecture genre. The adjective green expresses architectural qualities differentiating green architecture from none-green architecture. Currently, adding trees and vegetation to the building’s facade is the main architectural characteristics...... they have overshadowed the architectural potential of green architecture. The paper questions how a green space should perform, look like and function. Two examples are chosen to demonstrate thorough integrations between green and space. The examples are public buildings categorized as pavilions. One......The paper investigates the topic of green architecture from an architectural point of view and not an energy point of view. The purpose of the paper is to establish a debate about the architectural language and spatial characteristics of green architecture. In this light, green becomes an adjective...

  1. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Green business will remain green

    International Nuclear Information System (INIS)

    Marcan, P.

    2008-01-01

    It all started with two words. Climate change. The carbon dioxide trading scheme, which was the politicians' idea on solving the number one global problem, followed. Four years ago, when the project was begun, there was no data for project initiation. Quotas for polluters mainly from energy production and other energy demanding industries were distributed based on spreadsheets, maximum output and expected future development of economies. Slovak companies have had a chance to profit from these arrangements since 2005. Many of them took advantage of the situation and turned the excessive quotas into an extraordinary profit which often reached hundreds of million Sk. The fact that the price of free quotas offered for sale dropped basically to 0 in 2006 only proved that the initial distribution was too generous. And the market reacted to the first official measurements of emissions. Slovak companies also contributed to this development. However, when planning the maximum emission volumes for 2008-2012 period, in spite of the fact that actual data were available, their expectations were not realistic. A glance at the figures in the proposal of the Ministry of Environment is sufficient to realize that there will be no major change in the future. And so for many Slovak companies business with a green future will remain green for the next five years. The state decided to give to selected companies even more free space as far as emissions are concerned. The most privileged companies can expect quotas increased by tens of percent. (author)

  3. [Cost analysis of intraoperative neurophysiological monitoring (IOM)].

    Science.gov (United States)

    Kombos, T; Suess, O; Brock, M

    2002-01-01

    A number of studies demonstrate that a significant reduction of postoperative neurological deficits can be achieved by applying intraoperative neurophysiological monitoring (IOM) methods. A cost analysis of IOM is imperative considering the strained financial situation in the public health services. The calculation model presented here comprises two cost components: material and personnel. The material costs comprise consumer goods and depreciation of capital goods. The computation base was 200 IOM cases per year. Consumer goods were calculated for each IOM procedure respectively. The following constellation served as a basis for calculating personnel costs: (a) a medical technician (salary level BAT Vc) for one hour per case; (b) a resident (BAT IIa) for the entire duration of the measurement, and (c) a senior resident (BAT Ia) only for supervision. An IOM device consisting of an 8-channel preamplifier, an electrical and acoustic stimulator and special software costs 66,467 euros on the average. With an annual depreciation of 20%, the costs are 13,293 euros per year. This amounts to 66.46 euros per case for the capital goods. For reusable materials a sum of 0.75 euro; per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euro; per case were,s a sum of 0.75 euros per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euros per case were, calculated for surgery on the peripheral nervous system. They amount to 196.40 euros per case for spinal interventions and to 347.63 euros per case for more complex spinal operations. Operations in the cerebellopontine angle and brain stem cost 376.63 euros and 397.33 euros per case respectively. IOM costs amount to 328.03 euros per case for surgical management of an intracranial aneurysm and to 537.15 euros per case for functional interventions. Expenses run up to 833.63 euros per case for operations near the

  4. Green Power Partner Resources

    Science.gov (United States)

    EPA Green Power Partners can access tools and resources to help promote their green power commitments. Partners use these tools to communicate the benefits of their green power use to their customers, stakeholders, and the general public.

  5. Green Vehicle Guide

    Science.gov (United States)

    ... label Buy green. Save green. Learn about MPG math Discover fuel-saving tips Promote green ... U.S. consumers who have already purchased new vehicles under the fuel economy & greenhouse gas standard! More about the standards » Check ...

  6. Green Transformational Leadership and Green Performance: The Mediation Effects of Green Mindfulness and Green Self-Efficacy

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2014-09-01

    Full Text Available No prior literature explores the influence of green transformational leadership on green performance, thus, this study develops a novel research framework to fill the research gap. This study investigates the influence of green transformational leadership on green performance and discusses the mediation effects of green mindfulness and green self-efficacy by means of structural equation modeling (SEM. The results indicate that green transformational leadership positively influences green mindfulness, green self-efficacy, and green performance. Moreover, this study demonstrates that the positive relationship between green transformational leadership and green performance is partially mediated by the two mediators: green mindfulness and green self-efficacy. It means that green transformational leadership can not only directly affect green performance positively but also indirectly affect it positively through green mindfulness and green self-efficacy. Therefore, firms need to raise their green transformational leadership, green mindfulness, and green self-efficacy to increase their green performance.

  7. Dry Eye Following Phacoemulsification Surgery and its Relation to Associated Intraoperative Risk Factors.

    Science.gov (United States)

    Sahu, P K; Das, G K; Malik, Aman; Biakthangi, Laura

    2015-01-01

    The purpose was to study dry eye following phacoemulsification surgery and analyze its relation to associated intra-operative risk factors. A prospective observational study was carried out on 100 eyes of 100 patients without preoperative dry eye. Schirmer's Test I, tear meniscus height, tear break-up time, and lissamine green staining of cornea and conjunctiva were performed preoperatively and at 5 days, 10 days, 1-month, and 2 months after phacoemulsification surgery, along with the assessment of subjective symptoms, using the dry eye questionnaire. The correlations between these values and the operating microscope light exposure time along with the cumulative dissipated energy (CDE) were investigated. There was a significant deterioration of all dry eye test values following phacoemulsification surgery along with an increase in subjective symptoms. These values started improving after 1-month postoperatively, but preoperative levels were not achieved till 2 months after surgery. Correlations of dry eye test values were noted with the operating microscope light exposure time and CDE, but they were not significant. Phacoemulsification surgery is capable of inducing dry eye, and patients should be informed accordingly prior to surgery. The clinician should also be cognizant that increased CDE can induce dry eyes even in eyes that were healthy preoperatively. In addition, intraoperative exposure to the microscopic light should be minimized.

  8. A non-docking intraoperative electron beam applicator system

    International Nuclear Information System (INIS)

    Palta, J.R.; Suntharalingam, N.

    1989-01-01

    A non-docking intraoperative radiation therapy electron beam applicator system for a linear accelerator has been designed to minimize the mechanical, electrical, and tumor visualization problems associated with a docking system. A number of technical innovations have been used in the design of this system. These include: (a) a new intraoperative radiation therapy cone design that gives a better dose uniformity in the treatment volume at all depths; (b) a collimation system which reduces the leakage radiation dose to tissues outside the intraoperative radiation therapy cone; (c) a non-docking system with a translational accuracy of 2 mm and a rotational accuracy of 0.5 degrees; and (d) a rigid clamping system for the cones. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented

  9. Disparities between resident and attending surgeon perceptions of intraoperative teaching.

    Science.gov (United States)

    Butvidas, Lynn D; Anderson, Cheryl I; Balogh, Daniel; Basson, Marc D

    2011-03-01

    This study aimed to assess attending surgeon and resident recall of good and poor intraoperative teaching experiences and how often these experiences occur at present. By web-based survey, we asked US surgeons and residents to describe their best and worst intraoperative teaching experiences during training and how often 26 common intraoperative teaching behaviors occur in their current environment. A total of 346 residents and 196 surgeons responded (51 programs; 26 states). Surgeons and residents consistently identified trainee autonomy, teacher confidence, and communication as positive, while recalling negatively contemptuous, arrogant, accusatory, or uncommunicative teachers. Residents described intraoperative teaching behaviors by faculty as substantially less frequent than faculty self-reports. Neither sex nor seniority explained these results, although women reported communicative behaviors more frequently than men. Although veteran surgeons and current trainees agree on what constitutes effective and ineffective teaching in the operating room, they disagree on how often these behaviors occur, leaving substantial room for improvement. Published by Elsevier Inc.

  10. Value of intraoperative radiotherapy in locally advanced rectal cancer

    NARCIS (Netherlands)

    Ferenschild, Floris T. J.; Vermaas, Maarten; Nuyttens, Joost J. M. E.; Graveland, Wilfried J.; Marinelli, Andreas W. K. S.; van der Sijp, Joost R.; Wiggers, Theo; Verhoef, Cornelis; Eggermont, Alexander M. M.; de Wilt, Johannes H. W.

    PURPOSE: This study was designed to analyze the results of a multimodality treatment using preoperative radiotherapy, followed by surgery and intraoperative radiotherapy in patients with primary locally advanced rectal cancer. METHODS: Between 1987 and 2002, 123 patients with initial unresectable

  11. Presurgical mapping with magnetic source imaging. Comparisons with intraoperative findings

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Ferrari, P.; Perry, D.; Rowley, H.A.; Berger, M.S.

    2000-01-01

    We compare noninvasive preoperative mapping with magnetic source imaging to intraoperative cortical stimulation mapping. These techniques were directly compared in 17 patients who underwent preoperative and postoperative somatosensory mapping of a total of 22 comparable anatomic sites (digits, face). Our findings are presented in the context of previous studies that used magnetic source imaging and functional magnetic resonance imaging as noninvasive surrogates of intraoperative mapping for the identification of sensorimotor and language-specific brain functional centers in patients with brain tumors. We found that magnetic source imaging results were reasonably concordant with intraoperative mapping findings in over 90% of cases, and that concordance could be defined as 'good' in 77% of cases. Magnetic source imaging therefore provides a viable, if coarse, identification of somatosensory areas and, consequently, can guide and reduce the time taken for intraoperative mapping procedures. (author)

  12. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  13. Intraoperative management of ETT and LMA cufi pressures: a survey ...

    African Journals Online (AJOL)

    2008-07-16

    Jul 16, 2008 ... A study done by Stein et al. highlighted the inability of advanced life support ... Conclusion. There is increasing importance placed on quality assurance ... pressures – the worrying reality: a comparative audit of intra-operative.

  14. Association between intraoperative hypotension and myocardial injury after vascular surgery

    NARCIS (Netherlands)

    van Waes, JAR; Van Klei, Wilton A.; Wijeysundera, Duminda N.; Van Wolfswinkel, Leo; Lindsay, Thomas F.; Beattie, W. Scott

    2016-01-01

    Background: Postoperative myocardial injury occurs frequently after noncardiac surgery and is strongly associated with mortality. Intraoperative hypotension (IOH) is hypothesized to be a possible cause. The aim of this study was to determine the association between IOH and postoperative myocardial

  15. Intraoperative contamination influences wound discharge and periprosthetic infection

    NARCIS (Netherlands)

    Knobben, Bas A. S.; Engelsma, Yde; Neut, Danielle

    2006-01-01

    Intraoperative bacterial contamination increases risk for postoperative wound-healing problems and periprosthetic infection, but to what extent remains unclear. We asked whether bacterial contamination of the instruments and bone during primary prosthesis insertion was associated with prolonged

  16. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  17. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  18. Results of intraoperative radiotherapy for pancreatic cancers

    International Nuclear Information System (INIS)

    Okazaki, Atsushi; Shinozaki, Jun; Noda, Masanobu

    1991-01-01

    Reported are the results and observations of the authors who, from July 1986 through December 1989, have used electron beam intraoperative radiotherapy (IORT) on 20 patients with locally advanced pancreatic cancers, said number including 3 patients given a resection. In 14 of the 17 unresected patients, a chief symptom was pain, and 8 patients were given a celiac plexus block at the same time. The results and observations are given below. Life-threatening complications occurred in two patients, i.e., an insufficient pancreatojejunostomy, and a perforative peritonitis. In 12 of 13 evaluable patients, pain control was achieved for a mean period of 5 months, indicating that an IORT with celiac plexus block may be useful for palliation. In the resected patients, the mean survival time was 6 months, whereas in the unresected patients, the mean survival time was 7 months. The common cause of death in the unresected patients was a metastatic dissemination. Finally, in 3 of the 5 unresected patients, marked effects such as massive fibrosis were seen in the pancreatic tumor on autopsy. (author)

  19. Intraoperative radiation therapy for malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Noboru; Yamada, Hiromu; Andoh, Takashi; Hirata, Toshifumi; Nishimura, Yasuaki; Miwa, Yoshiaki; Shimizu, Kotoyuki; Yanagawa, Shigeo [Gifu Univ. (Japan). Faculty of Medicine

    1991-11-01

    Intraoperative radiation therapy (IORT) was used as part of the initial therapy for malignant glioma in 32 of 73 patients with histologically verified anaplastic astrocytoma (grade III astrocytoma) and glioblastoma multiforme. The initial treatment for all cases was subtotal or total tumor resection combined with external irradiation and chemotherapy. IORT was performed 1 week after tumor resection, with doses of 10-50 Gy (mean 26.7 Gy) in one session. Fourteen of 32 cases had IORT two times because of tumor recurrence. The IORT patients had survival rates at 24 and 36 months after initial treatment of 57.1 and 33.5% (median survival 26.2 months). The other 41 patients had 23.6 and 13.1% survivals (median survival 20.7 months), which were significantly lower (p<0.01). Tumor recurrence within the original lesion site was suspected because of clinical condition, computed tomography, and magnetic resonance imaging studies in 65.6% of the IORT group (21 cases) 12 months after initial treatment. Twenty cases of death in the IORT group, including five autopsy cases, demonstrated regional tumor recurrence with a high incidence of intraventricular tumor invasion. The authors consider IORT is beneficial for selected malignant glioma patients, including tumor recurrence, because of prolonged survival. (author).

  20. Perspectives in Intraoperative Diagnostics of Human Gliomas

    Directory of Open Access Journals (Sweden)

    O. Tyurikova

    2015-01-01

    Full Text Available Amongst large a variety of oncological diseases, malignant gliomas represent one of the most severe types of tumors. They are also the most common type of the brain tumors and account for over half of the astrocytic tumors. According to different sources, the average life expectancy of patients with various glioblastomas varies between 10 and 12 months and that of patients with anaplastic astrocytic tumors between 20 and 24 months. Therefore, studies of the physiology of transformed glial cells are critical for the development of treatment methods. Modern medical approaches offer complex procedures, including the microsurgical tumor removal, radiotherapy, and chemotherapy, supplemented with photodynamic therapy and immunotherapy. The most radical of them is surgical resection, which allows removing the largest part of the tumor, reduces the intracranial hypertension, and minimizes the degree of neurological deficit. However, complete removal of the tumor remains impossible. The main limitations are insufficient visualization of glioma boundaries, due to its infiltrative growth, and the necessity to preserve healthy tissue. This review is devoted to the description of advantages and disadvantages of modern intraoperative diagnostics of human gliomas and highlights potential perspectives for development of their treatment.

  1. Central Region Green Infrastructure

    Data.gov (United States)

    Minnesota Department of Natural Resources — This Green Infrastructure data is comprised of 3 similar ecological corridor data layers ? Metro Conservation Corridors, green infrastructure analysis in counties...

  2. The green building envelope : Vertical greening

    NARCIS (Netherlands)

    Ottelé, M.

    2011-01-01

    Planting on roofs and façades is one of the most innovative and fastest developing fields of green technologies with respect to the built environment and horticulture. This thesis is focused on vertical greening of structures and to the multi-scale benefits of vegetation. Vertical green can improve

  3. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    Science.gov (United States)

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  4. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    OpenAIRE

    Lee, Su-Keon; Lee, Seung-Hwan; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondyloli...

  5. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  6. How Green is 'Green' Energy?

    Science.gov (United States)

    Gibson, Luke; Wilman, Elspeth N; Laurance, William F

    2017-12-01

    Renewable energy is an important piece of the puzzle in meeting growing energy demands and mitigating climate change, but the potentially adverse effects of such technologies are often overlooked. Given that climate and ecology are inextricably linked, assessing the effects of energy technologies requires one to consider their full suite of global environmental concerns. We review here the ecological impacts of three major types of renewable energy - hydro, solar, and wind energy - and highlight some strategies for mitigating their negative effects. All three types can have significant environmental consequences in certain contexts. Wind power has the fewest and most easily mitigated impacts; solar energy is comparably benign if designed and managed carefully. Hydropower clearly has the greatest risks, particularly in certain ecological and geographical settings. More research is needed to assess the environmental impacts of these 'green' energy technologies, given that all are rapidly expanding globally. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  8. Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.

    Science.gov (United States)

    Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak

    2017-07-01

    Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score Secondary insults examined were: systemic hypotension (systolic blood pressurehypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure40 mm Hg), hypocarbia (end-tidal CO2hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (Psecondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.

  9. Intraoperative complications in pediatric neurosurgery: review of 1807 cases.

    Science.gov (United States)

    van Lindert, Erik J; Arts, Sebastian; Blok, Laura M; Hendriks, Mark P; Tielens, Luc; van Bilsen, Martine; Delye, Hans

    2016-09-01

    OBJECTIVE Minimal literature exists on the intraoperative complication rate of pediatric neurosurgical procedures with respect to both surgical and anesthesiological complications. The aim of this study, therefore, was to establish intraoperative complication rates to provide patients and parents with information on which to base their informed consent and to establish a baseline for further targeted improvement of pediatric neurosurgical care. METHODS A clinical complication registration database comprising a consecutive cohort of all pediatric neurosurgical procedures carried out in a general neurosurgical department from January 1, 2004, until July 1, 2012, was analyzed. During the study period, 1807 procedures were performed on patients below the age of 17 years. RESULTS Sixty-four intraoperative complications occurred in 62 patients (3.5% of procedures). Intraoperative mortality was 0.17% (n = 3). Seventy-eight percent of the complications (n = 50) were related to the neurosurgical procedures, whereas 22% (n = 14) were due to anesthesiology. The highest intraoperative complication rates were for cerebrovascular surgery (7.7%) and tumor surgery (7.4%). The most frequently occurring complications were cerebrovascular complications (33%). CONCLUSIONS Intraoperative complications are not exceptional during pediatric neurosurgical procedures. Awareness of these complications is the first step in preventing them.

  10. Intraoperative MRI to control the extent of brain tumor surgery

    International Nuclear Information System (INIS)

    Knauth, M.; Sartor, K.; Wirtz, C.R.; Tronnier, V.M.; Staubert, A.; Kunze, S.

    1998-01-01

    Intraoperative MRI definitely showed residual tumor in 6 of the 18 patients and resulted in ambiguous findings in 3 patients. In 7 patients surgery was continued. Early postoperative MRI showed residual tumor in 3 patients and resulted in uncertain findings in 2 patients. The rate of patients in whom complete removal of enhancing tumor could be achieved was 50% at the time of the intraoperative MR examination and 72% at the time of the early postoperative MR control. The difference in proportion of patients with 'complete tumor removal' between the groups who had been operated on using neuronavigation (NN) and intraoperative MRI (ioMRI) and those who had been operated on using only modern neurosurgical techniques except NN and ioMRI was statistically highly significant (Fisher exact test; P=0.008). Four different types of surgically induced contrast enhancement were observed. These phenomena carry different confounding potentials with residual tumor. Conclusion: Our preliminary experience with intraoperative MRI in patients with enhancing intraaxial tumors is encouraging. Combined use of neuronavigation and intraoperative MRI was able to increase the proportion of patients in whom complete removal of the enhancing parts of the tumor was achieved. Surgically induced enhancement requires careful analysis of the intraoperative MRI in order not to confuse it with residual tumor. (orig.) [de

  11. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    Science.gov (United States)

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  12. Intraoperative HDR brachytherapy for rectal cancer using a flexible intraoperative template: standard plans versus individual planning

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Nuyttens, Joost J.; Hanssens, Patrick E.J.; Levendag, Peter C.

    2004-01-01

    HDR intraoperative brachytherapy (IOBT) is applied to locally advanced rectal tumors using a 5 mm thick flexible intraoperative template (FIT). To reduce the procedure time, treatment planning is performed using standard plans that neglect the curvature of the FIT. We have calculated the individual treatment plan, based on the real geometry of the FIT, and the dose at clips placed during surgery. A mean treatment dose of 9.55±0.21 Gy was found for the individual plan, compared to the prescribed 10 Gy (P<0.0001). The mean central dose was 10.03±0.10 Gy in the standard plan and 9.20±0.32 Gy in the individual plan (P<0.0001). The mean dose at the corners of the FIT was 10.3 Gy in the standard plan and ranged between 10.3 and 10.5 Gy in the individual plan. In 63% of the clips, the dose was larger than 15.0 Gy, which is equivalent to a gap between the FIT and the target smaller than 5 mm. In 18% of the clips, the dose was smaller than 13.0 Gy indicating that locally the gap was larger than 5 mm. Clinical practice will have to prove if these small dose deviations influence the clinical outcome

  13. Intraoperative radiation therapy for malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Noboru; Yamada, Hiromu; Andoh, Takashi; Takada, Mitsuaki; Hirata, Toshifumi; Funakoshi, Takashi; Doi, Hidetaka; Yanagawa, Shigeo [Gifu Univ. (Japan). Faculty of Medicine

    1989-04-01

    Intraoperative radiation therapy (IOR) is an ideal means of exterminating residual tumor after surgical resection. In this study, the clinical results of IOR using a Scanditronix Microtron MM-22 were evaluated in 14 patients with malignant glioma, five of whom had recurrent tumors. Between July, 1985 and October, 1986, 11 patients with glioblastoma multiforme (GB) were irradiated 18 times (mean, 1.6 times/case), and three with astrocytoma (Kernohan grade III) underwent IOR once each. The target-absorbed dose at 1 to 2 cm deeper than the tumor resection surface was 15 to 50 Gy. During irradiation, a cotton bolus was placed in the dead space after over 91% of the tumor had been resected. As a rule, external irradiation therapy was also given postoperatively at a dose of 30 to 52 Gy. One patient died of pneumonia and disseminated intravascular coagulation syndrome 1 month postoperatively. The 1- and 2-year survival rates of the ramaining 13 patients were 84.6% and 61.5%, respectively; among the 10 with GB, they were 80% and 50%. Generally, the smaller the tumor size, the better the results. There were no adverse effects, despite the dose 15 to 50 Gy applied temporally to the tumor bed. IOR was especially effective against small, localized tumors, but was not always beneficial in cases of large tumors, particularly those with a contralateral focus. The improved survival rate in this series demonstrates that IOR is significantly effective in the 'induction of remission' following surgical excision of malignant gliomas. (author).

  14. How do pediatric anesthesiologists define intraoperative hypotension?

    Science.gov (United States)

    Nafiu, Olubukola O; Voepel-Lewis, Terri; Morris, Michelle; Chimbira, Wilson T; Malviya, Shobha; Reynolds, Paul I; Tremper, Kevin K

    2009-11-01

    Although blood pressure (BP) monitoring is a recommended standard of care by the ASA, and pediatric anesthesiologists routinely monitor the BP of their patients and when appropriate treat deviations from 'normal', there is no robust definition of hypotension in any of the pediatric anesthesia texts or journals. Consequently, what constitutes hypotension in pediatric anesthesia is currently unknown. We designed a questionnaire-based survey of pediatric anesthesiologists to determine the BP ranges and thresholds used to define intraoperative hypotension (IOH). Members of the Society of Pediatric Anesthesia (SPA) and the Association of Paediatric Anaesthetists (APA) of Great Britain and Ireland were contacted through e-mail to participate in this survey. We asked a few demographic questions and five questions about specific definitions of hypotension for different age groups of patients undergoing inguinal herniorraphy, a common pediatric surgical procedure. The overall response rate was 56% (483/860), of which 76% were SPA members. Majority of the respondents (72%) work in academic institutions, while 8.9% work in institutions with fewer than 1000 annual pediatric surgical caseload. About 76% of respondents indicated that a 20-30% reduction in baseline systolic blood pressure (SBP) indicates significant hypotension in children under anesthesia. Most responders (86.7%) indicated that they use mean arterial pressure or SBP (72%) to define IOH. The mean SBP values for hypotension quoted by SPA members was about 5-7% lower across all pediatric age groups compared to values quoted by APA members (P = 0.001 for all age groups). There is great variability in the BP parameters used and the threshold used for defining and treating IOH among pediatric anesthesiologists. The majority of respondents considered a 20-30% reduction from baseline in SBP as indicative of significant hypotension. Lack of a consensus definition for a common clinical condition like IOH could have

  15. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  16. Neurophysiologic intraoperative monitoring of the vestibulocochlear nerve.

    Science.gov (United States)

    Simon, Mirela V

    2011-12-01

    Neurosurgical procedures involving the skull base and structures within can pose a significant risk of damage to the brain stem and cranial nerves. This can have life-threatening consequences and/or result in devastating neurologic deficits. Over the past decade, intraoperative neurophysiology has significantly evolved and currently offers a great tool for live monitoring of the integrity of nervous structures. Thus, dysfunction can be identified early and prompt modification of the surgical management or operating conditions, leads to avoidance of permanent structural damage.Along these lines, the vestibulocochlear nerve (CN VIII) and, to a greater extent, the auditory pathways as they pass through the brain stem are especially at risk during cerebelopontine angle (CPA), posterior/middle fossa, or brain stem surgery. CN VIII can be damaged by several mechanisms, from vascular compromise to mechanical injury by stretch, compression, dissection, and heat injury. Additionally, cochlea itself can be significantly damaged during temporal bone drilling, by noise, mechanical destruction, or infarction, and because of rupture, occlusion, or vasospasm of the internal auditory artery.CN VIII monitoring can be successfully achieved by live recording of the function of one of its parts, the cochlear or auditory nerve (AN), using the brain stem auditory evoked potentials (BAEPs), electrocochleography (ECochG), and compound nerve action potentials (CNAPs) of the cochlear nerve.This is a review of these techniques, their principle, applications, methodology, interpretation of the evoked responses, and their change from baseline, within the context of surgical and anesthesia environments, and finally the appropriate management of these changes.

  17. Unfolding Green Defense

    DEFF Research Database (Denmark)

    Larsen, Kristian Knus

    2015-01-01

    In recent years, many states have developed and implemented green solutions for defense. Building on these initiatives NATO formulated the NATO Green Defence Framework in 2014. The framework provides a broad basis for cooperation within the Alliance on green solutions for defense. This report aims...... to inform and support the further development of green solutions by unfolding how green technologies and green strategies have been developed and used to handle current security challenges. The report, initially, focuses on the security challenges that are being linked to green defense, namely fuel...... consumption in military operations, defense expenditure, energy security, and global climate change. The report then proceeds to introduce the NATO Green Defence Framework before exploring specific current uses of green technologies and green strategies for defense. The report concludes that a number...

  18. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  19. Green industrial policy

    OpenAIRE

    Dani Rodrik

    2014-01-01

    Green growth requires green technologies: production techniques that economize on exhaustible resources and emit fewer greenhouse gases. The availability of green technologies both lowers social costs in the transition to a green growth path and helps achieve a satisfactory rate of material progress under that path. The theoretical case in favour of using industrial policy to facilitate green growth is quite strong. Economists’ traditional scepticism on industrial policy is grounded instead o...

  20. The use of intraoperative computed tomography navigation in pituitary surgery promises a better intraoperative orientation in special cases

    Directory of Open Access Journals (Sweden)

    Stefan Linsler

    2016-01-01

    Full Text Available Objective: The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT and magnetic resonance imaging (MRI. Here, we report our initial experience of real-time intraoperative CT-guided navigation surgery for pituitary tumors in childhood. Materials and Methods: We report the case of a 15-year-old girl with a huge growth hormone-secreting pituitary adenoma with supra- and perisellar extension. Furthermore, the skull base was infiltrated. In this case, we performed an endonasal transsphenoidal approach for debulking the adenoma and for chiasma decompression. We used an MRI neuronavigation (Medtronic Stealth Air System which was registered via intraoperative CT scan (Siemens CT Somatom. Preexisting MRI studies (navigation protocol were fused with the intraoperative CT scans to enable three-dimensional navigation based on MR and CT imaging data. Intraoperatively, we did a further CT scan for resection control. Results: The intraoperative accuracy of the neuronavigation was excellent. There was an adjustment of <1 mm. The navigation was very helpful for orientation on the destroyed skull base in the sphenoid sinus. After opening the sellar region and tumor debulking, we did a CT scan for resection control because the extent of resection was not credible evaluable in this huge infiltrating adenoma. Thereby, we were able to demonstrate a sufficient decompression of the chiasma and complete resection of the medial part of the adenoma in the intraoperative CT images. Conclusions: The use of intraoperative CT/MRI-guided neuronavigation for transsphenoidal surgery is a time-effective, safe, and technically beneficial technique for special cases.

  1. Intraoperative use of ultrasonography by small subcortical lesions

    International Nuclear Information System (INIS)

    Kondoff, Sl.; Gabrovski, St.; Krustev, E.; Poptodorov, G.; Gabrovski, N.; Uzunov, K.

    2004-01-01

    The aim of this study is to present the possibilities for use of intraoperative ultrasound (US) diagnostics as a method of image guided surgical navigation in neurosurgery. During an US scan of normal and pathologically changed tissues as well as volume taking lesion images are received in real time intraoperative display allowing dynamic control of the surgical radicalism and at the same time minimal invasiveness to the neural structures. Intraoperative ultrasound with real-time display characteristics finds a very wide application: subcortical and deeply localized tumour lesions, haematomas, large and giant aneurysms, arteriovenous (AV) malformations, spinal tumours and cysts. The real time dynamic scan is based on the B-mod. This method is founded on the US characteristic of reflecting in a different manner at the borderline of two mediums with different density as well as tissues with various physical and chemical characteristics. The reflection is partially absorbed depending on the acoustic impedance of the biologic field. We use a LOGIC200PRO unit with two probes I-type and T-type having a 'wedge of space' - 35 mm and working frequencies of 6 MHz and 7 MHz appropriate for visualizing lesions at a depth of 25 to 60 mm.The advantages of the Intraoperative US diagnostics are: non-invasiveness; real time display - i.e. presents the imminent intraoperative changes; it is a good alternative to other image-guided technologies; accessible price of the US unit

  2. Selected versus routine use of intraoperative cholangiography during laparoscopic cholecystectomy.

    Science.gov (United States)

    Pickuth, D

    1995-12-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments, however, this is discussed controversially. We have developed a new diagnostic strategy to detect bile duct stones. The concept is based on an ultrasound examination and on a screening for the presence of six risk indicators of choledocholithiasis. 120 consecutive patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of six risk indicators of choledocholithiasis: history of jaundice; history of pancreatitis; hyperbilirubinemia; hyperamylasemia; dilated bile duct; unclear ultrasound findings. The sensitivity of ultrasound and of intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. 20% of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (p concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that the routine use of intraoperative cholangiography in patients undergoing laparoscopic cholecystectomy is not necessary.

  3. Role of scrape cytology in the intraoperative diagnosis of tumor

    Directory of Open Access Journals (Sweden)

    Kolte Sachin

    2010-01-01

    Full Text Available Background : Rapid diagnosis of surgically removed specimens has created many controversies and a single completely reliable method has not yet been developed. Histopathology of a paraffin section remains the ultimate gold standard in tissue diagnosis. Frozen section is routinely used by the surgical pathology laboratories for intraoperative diagnosis. The use of either frozen section or cytological examination alone has an acceptable rate (93-97% of correct diagnosis, with regard to interpretation of benign versus malignant. Aim : To evaluate the utility of scrape cytology for the rapid diagnosis of surgically removed tumors and its utilisation for learning cytopathology. Materials and Methods : 75 surgically removed specimens from various organs and systems were studied. Scrapings were taken from each specimen before formalin fixation and stained by modified rapid Papanicolaou staining. Results : Of the 75 cases studied, 73 could be correctly differentiated into benign and malignant tumors, with an accuracy rate of 97.3%. Conclusions : Intraoperative scrape cytology is useful for intraoperative diagnosis of tumor, where facilities for frozen section are not available. The skill and expertise developed by routinely practicing intraoperative cytology can be applied to the interpretation of fine needle aspirate smears. Thus, apart from its diagnostic role, intraoperative cytology can become a very useful learning tool in the field of cytopathology.

  4. [Factors related to intraoperative retinal breaks in macular hole surgery].

    Science.gov (United States)

    Kumagai, K; Ogino, N; Demizu, S; Atsumi, K; Kurihara, H; Iwaki, M; Ishigooka, H; Tachi, N

    2001-02-01

    To evaluate the factors of intraoperative retinal breaks in macular hole surgery. This study included 558 eyes of 506 patients who underwent idiopathic macular hole surgery by one surgeon. Multiple regression was performed using the variables of gender, age, affected eye, lens status, stage, duration of symptoms, hole size, axial length, and lattice degeneration. The rate of retinal breaks was higher in stage 3 (16.0%) than in stage 4 (8.2%) (p = 0.014). In eyes with lattice degeneration intraoperative retinal breaks occurred in about 40% of the cases. Major factors were as follows: lattice degeneration (r = 0.24, p lattice degeneration, and gender (r = -0.18, p = 0.035) in eyes of stage 4 without lattice degeneration. The factors of intraoperative retinal breaks in macular hole surgery were lattice degeneration in all eyes and stage 3 in eyes without lattice degeneration. The high incidence of intraoperative retinal breaks in stage 3 was mainly due to the occurrence of posterior vitreous detachment. Male gender was a significant factor associated with intraoperative retinal breaks.

  5. Intraoperative parathyroid hormone assay-cutting the Gordian knot

    Directory of Open Access Journals (Sweden)

    Chandralekha Tampi

    2014-01-01

    Full Text Available Background: Hyperparathyroidism is treated by surgical excision of the hyperfunctioning parathyroid gland. In case of adenoma the single abnormal gland is removed, while in hyperplasias, a subtotal excision, that is, three-and-a-half of the four glands are removed. This therapeutic decision is made intraoperatively through frozen section evaluation and is sometimes problematic, due to a histological overlap between hyperplasia and the adenoma. The intraoperative parathyroid hormone (IOPTH assay, propogated in recent years, offers an elegant solution, with a high success rate, due to its ability to identify the removal of all hyperfunctioning parathyroid tissue. Aim: To study the feasibility of using IOPTH in our setting. Materials and Methods: Seven patients undergoing surgery for primary hyperparathyroidism had their IOPTH levels evaluated, along with the routine frozen and paraffin sections. Results: All seven patients showed more than a 50% intraoperative fall in serum PTH after excision of the abnormal gland. This was indicative of an adenoma and was confirmed by histopathological examination and normalization of serum calcium postoperatively. Conclusion: The intraoperative parathyroid hormone is a sensitive and specific guide to a complete removal of the abnormal parathyroid tissue. It can be incorporated without difficulty as an intraoperative guide and is superior to frozen section diagnosis in parathyroid surgery.

  6. Intraoperative adverse events associated with extremely preterm cesarean deliveries.

    Science.gov (United States)

    Bertholdt, Charline; Menard, Sophie; Delorme, Pierre; Lamau, Marie-Charlotte; Goffinet, François; Le Ray, Camille

    2018-05-01

    At the same time as survival is increasing among premature babies born before 26 weeks of gestation, the rates of cesarean deliveries before 26 weeks is also rising. Our purpose was to compare the frequency of intraoperative adverse events during cesarean deliveries in two gestational age groups: 24-25 weeks and 26-27 weeks. This single-center retrospective cohort study included all women with cesarean deliveries performed before 28 +0 weeks from 2007 through 2015. It compared the frequency of intraoperative adverse events between two groups: those at 24-25 weeks of gestation and at 26-27 weeks. Intraoperative adverse events were a classical incision, transplacental incision, difficulty in fetal extraction (explicitly mentioned in the surgical report), postpartum hemorrhage (≥500 mL of blood loss), and injury to internal organs. A composite outcome including at least one of these events enabled us to analyze the risk factors for intraoperative adverse events with univariate and multivariable analysis. Stratified analyses by the indication for the cesarean were performed. We compared 74 cesarean deliveries at 24-25 weeks of gestation and 214 at 26-27 weeks. Intraoperative adverse events occurred at higher rates in the 24-25-week group (63.5 vs. 30.8%, p cesarean. These results should help obstetricians and women making decisions about cesarean deliveries at these extremely low gestational ages. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  7. Intraoperative and early postoperative complications of manual sutureless cataract extraction.

    Science.gov (United States)

    Iqbal, Yasir; Zia, Sohail; Baig Mirza, Aneeq Ullah

    2014-04-01

    To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Case series. Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema.

  8. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (United States)

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  9. Intraoperative ultrasonography for presumed brain metastases: a case series study

    Directory of Open Access Journals (Sweden)

    Helder Picarelli

    2012-10-01

    Full Text Available Brain metastases (BM are one of the most common intracranial tumors and surgical treatment can improve both the functional outcomes and patient survival, particularly when systemic disease is controlled. Image-guided BM resection using intraoperative exams, such as intraoperative ultrasound (IOUS, can lead to better surgical results. METHODS: To evaluate the use of IOUS for BM resection, 20 consecutives patients were operated using IOUS to locate tumors, identify their anatomical relationships and surgical cavity after resection. Technical difficulties, complications, recurrence and survival rates were noted. RESULTS: IOUS proved effective for locating, determining borders and defining the anatomical relationships of BM, as well as to identify incomplete tumor resection. No complications related to IOUS were seen. CONCLUSION: IOUS is a practical supporting method for the resection of BM, but further studies comparing this method with other intraoperative exams are needed to evaluate its actual contribution and reliability.

  10. Intraoperative magnetic resonance imaging for neurosurgery – An anaesthesiologist's challenge

    Directory of Open Access Journals (Sweden)

    Rajashree U Gandhe

    2018-01-01

    Full Text Available Intraoperative magnetic resonance imaging (MRI-guided neurosurgery has gained popularity over the years globally. These surgeries require a dedicated operating room and MRI-compatible anaesthesia equipment. The anaesthesiologist providing care in this setup needs to be experienced and vigilant to ensure patient safety. Strict adherence to MRI safety checklists and regular personnel training would avoid potential accidents and life-threatening emergencies. Teamwork, good communication, preprocedure planning, and familiarity with the surroundings are very important for safe care and good outcomes. We performed a literature search in Google Scholar, PubMed and Cochrane databases for original and reviewed articles for the origins, development and applications of intraoperative MRI in neurosurgical procedures. Much of the research has emphasised on the surgical indications than the anaesthetic challenges faced during intraoperative MRI guided surgery. The purpose of this review is to discuss the anaesthetic concerns specific to this unique environment.

  11. Green corridors basics

    DEFF Research Database (Denmark)

    Panagakos, George

    2016-01-01

    SuperGreen project, which aimed at advancing the green corridor concept through a benchmarking exercise involving Key Performance Indicators (KPIs). The chapter discusses the available definitions of green corridors and identifies the characteristics that distinguish a green corridor from any other...... efficient surface transportation corridor. After providing examples of green corridor projects in Europe, it focuses on the KPIs that have been proposed by various projects for monitoring the performance of a freight corridor. Emphasis is given to the SuperGreen KPIs, covering the economic, technical...

  12. Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK.

    Science.gov (United States)

    Narváez, Julio; Brucks, Matthew; Zimmerman, Grenith; Bekendam, Peter; Bacon, Gregory; Schmid, Kristin

    2012-05-01

    To determine the degree of cyclorotation and centroid shift in the x and y axis that occurs intraoperatively during LASIK and photorefractive keratectomy (PRK). Intraoperative cyclorotation and centroid shift were measured in 63 eyes from 34 patients with a mean age of 34 years (range: 20 to 56 years) undergoing either LASIK or PRK. Preoperatively, an iris image of each eye was obtained with the VISX WaveScan Wavefront System (Abbott Medical Optics Inc) with iris registration. A VISX Star S4 (Abbott Medical Optics Inc) laser was later used to measure cyclotorsion and pupil centroid shift at the beginning of the refractive procedure and after flap creation or epithelial removal. The mean change in intraoperative cyclorotation was 1.48±1.11° in LASIK eyes and 2.02±2.63° in PRK eyes. Cyclorotation direction changed by >2° in 21% of eyes after flap creation in LASIK and in 32% of eyes after epithelial removal in PRK. The respective mean intraoperative shift in the x axis and y axis was 0.13±0.15 mm and 0.17±0.14 mm, respectively, in LASIK eyes, and 0.09±0.07 mm and 0.10±0.13 mm, respectively, in PRK eyes. Intraoperative centroid shifts >100 μm in either the x axis or y axis occurred in 71% of LASIK eyes and 55% of PRK eyes. Significant changes in cyclotorsion and centroid shifts were noted prior to surgery as well as intraoperatively with both LASIK and PRK. It may be advantageous to engage iris registration immediately prior to ablation to provide a reference point representative of eye position at the initiation of laser delivery. Copyright 2012, SLACK Incorporated.

  13. Glioma surgery using intraoperative tractography and MEP monitoring

    International Nuclear Information System (INIS)

    Maesawa, Satoshi; Nakahara, Norimoto; Watanabe, Tadashi; Fujii, Masazumi; Yoshida, Jun

    2009-01-01

    In surgery of gliomas in motor-eloquent locations, it is essential to maximize resection while minimizing motor deficits. We attempted to identify the cortico-spinal tract (CST) by intraoperative-diffusion tensor imaging (DTI) tractography, combined with electrophysiological mapping using direct subcortical stimulation during tumor resection. Our techniques and preliminary results are reported. Tumors were removed from twelve patients with gliomas in and around the CST using high-field intraoperative MRI and neuronavigation system (BrainSUITE). DTI-based tractography was implemented for navigation of CST pre-and intraoperatively. When the CST was close to the manipulating area, direct subcortical stimulation was performed, and motor evoked potential (MEP)-responses were examined. Locations of CST indicated by pre- and intraoperative tractography (pre- or intra-CST-tractography), and locations identified by subcortical stimulation were recorded, and those correlations were examined. Imaging and functional outcomes were reviewed. Total resections were achieved in 10 patients (83.4%). Two patients developed transient deterioration of motor function (16.6%), and permanent paresis was seen in one (8.3%). The distance from intra-CST-tractography to corresponding sites by subcortical stimulation was 4.5 mm in average (standard deviation (SD)=4.2), and significantly shorter than from pre-CST-tractography. That distance correlated significantly with the intensity of subcortical stimulation. We observed that intraoperative DTI-tractography demonstrated the location of the pyramidal tract more accurately than preoperative one. The combination of intraoperative tractgraphy and MEP monitoring enhanced the quality of surgery for gliomas in motor-eloquent area. (author)

  14. Pygopagus Conjoined Twins: A Neurophysiologic Intraoperative Monitoring Schema.

    Science.gov (United States)

    Cromeens, Barrett P; McKinney, Jennifer L; Leonard, Jeffrey R; Governale, Lance S; Brown, Judy L; Henry, Christina M; Levitt, Marc A; Wood, Richard J; Besner, Gail E; Islam, Monica P

    2017-03-01

    Conjoined twins occur in up to 1 in 50,000 live births with approximately 18% joined in a pygopagus configuration at the buttocks. Twins with this configuration display symptoms and carry surgical risks during separation related to the extent of their connection which can include anorectal, genitourinary, vertebral, and neural structures. Neurophysiologic intraoperative monitoring for these cases has been discussed in the literature with variable utility. The authors present a case of pygopagus twins with fused spinal cords and imperforate anus where the use of neurophysiologic intraoperative monitoring significantly impacted surgical decision-making in division of these critical structures.

  15. Intraoperative ultrasound to facilitate removal of a submucosal foreign body.

    Science.gov (United States)

    Smith, Matthew E; Riffat, Faruque; Berman, Laurence H; Jani, Piyush

    2014-01-01

    A 61-year-old man with a history of fish bone ingestion and poorly localized symptoms was seen. His clinical examination was unremarkable, but CT demonstrated a foreign body deeply embedded within his tongue. Intraoperative ultrasound (US) guidance facilitated identification of a bone, allowing a needle to be placed as a guide to dissection. Repeat US scanning through the incision permitted precisely targeted surgery. CT and US are the most effective imaging techniques for localizing fish bones. Intraoperative US can be used to accurately locate a submucosal fish bone in mobile tissue such as the tongue, and focused, image-guided dissection can reduce surgical tissue trauma. © 2014 Wiley Periodicals, Inc.

  16. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    Directory of Open Access Journals (Sweden)

    Terrence T. Kim

    2016-01-01

    Full Text Available We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy.

  17. Green Power Partnership 100 Green Power Users

    Science.gov (United States)

    EPA's Green Power Partnership is a voluntary program designed to reduce the environmental impact of electricity generation by promoting renewable energy. Partners on this list use green power to meet 100 of their U.S. organization-wide electricity use.

  18. Intravenous dexmedetomidine infusion in adult patients undergoing open nephrolithotomy: Effects on intraoperative hemodynamics and blood loss; a random

    Directory of Open Access Journals (Sweden)

    Doaa A. Rashwan

    2015-10-01

    Conclusion: Dexmedetomidine infusion in patients undergoing open nephrolithotomy under general anesthesia was associated with intraoperative hemodynamic stability, which decreases intraoperative blood loss and the need for intraoperative blood transfusion.

  19. Urban Greening Bay Area

    Science.gov (United States)

    Information about the San Francisco Bay Water Quality Project (SFBWQP) Urban Greening Bay Area, a large-scale effort to re-envision urban landscapes to include green infrastructure (GI) making communities more livable and reducing stormwater runoff.

  20. Tribal Green Building Toolkit

    Science.gov (United States)

    This Tribal Green Building Toolkit (Toolkit) is designed to help tribal officials, community members, planners, developers, and architects develop and adopt building codes to support green building practices. Anyone can use this toolkit!

  1. Green Power Partner List

    Science.gov (United States)

    The U.S. EPA's Green Power Partnership is a voluntary program designed to reduce the environmental impact of electricity generation by promoting renewable energy. There are thousands of Green Power Partners, all listed on this page.

  2. Green Power Communities

    Science.gov (United States)

    GPCs are towns, villages, cities, counties, or tribal governments in which the local government, businesses, and residents collectively use green power in amounts that meet or exceed EPA's Green Power Community purchase requirements.

  3. Blue-Green Algae

    Science.gov (United States)

    ... that taking a specific blue-green algae product (Super Blue-Green Algae, Cell Tech, Klamath Falls, OR) ... system. Premenstrual syndrome (PMS). Depression. Digestion. Heart disease. Memory. Wound healing. Other conditions. More evidence is needed ...

  4. Green Bank Observatory (GBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The largest fully steerable telescope in the world - the Robert C. Byrd Green Bank Telescope (GBT), began observations in Green Bank, West Virginia in 2000and is a...

  5. Green Infrastructure Modeling Toolkit

    Science.gov (United States)

    Green infrastructure, such as rain gardens, green roofs, porous pavement, cisterns, and constructed wetlands, is becoming an increasingly attractive way to recharge aquifers and reduce the amount of stormwater runoff that flows into wastewater treatment plants or into waterbodies...

  6. Effects of intraoperative irradiation and intraoperative hyperthermia on canine sciatic nerve: neurologic and electrophysiologic study

    International Nuclear Information System (INIS)

    Vujaskovic, Zeljko; Gillette, Sharon M.; Powers, Barbara E.; Stukel, Therese A.; LaRue, Susan M.; Gillette, Edward L.; Borak, Thomas B.; Scott, Robert J.; Weiss, Julia; Colacchio, Thomas A.

    1996-01-01

    Purpose: Late radiation injury to peripheral nerve may be the limiting factor in the clinical application of intraoperative radiation therapy (IORT). The combination of IORT with intraoperative hyperthermia (IOHT) raises specific concerns regarding the effects on certain normal tissues such as peripheral nerve, which might be included in the treatment field. The objective of this study was to compare the effect of IORT alone to the effect of IORT combined with IOHT on peripheral nerve in normal beagle dogs. Methods and Materials: Young adult beagle dogs were randomized into five groups of three to five dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy to 5 cm of surgically exposed right sciatic nerve using 6 MeV electrons and six groups of four to five dogs each received IORT doses of 0, 12, 16, 20, 24, or 28 Gy simultaneously with 44 deg. C of IOHT for 60 min. IOHT was performed using a water circulating hyperthermia device with a multichannel thermometry system on the surgically exposed sciatic nerve. Neurologic and electrophysiologic examinations were done before and monthly after treatment for 24 months. Electrophysiologic studies included electromyographic (EMG) examinations of motor function, as well as motor nerve conduction velocities studies. Results: Two years after treatment, the effective dose for 50% complication (ED 50 ) for limb paresis in dogs exposed to IORT only was 22 Gy. The ED 50 for paresis in dogs exposed to IORT combined with IOHT was 15 Gy. The thermal enhancement ratio (TER) was 1.5. Electrophysiologic studies showed more prominent changes such as EMG abnormalities, decrease in conduction velocity and amplitude of the action potential, and complete conduction block in dogs that received the combination of IORT and IOHT. The latency to development of peripheral neuropathies was shorter for dogs exposed to the combined treatment. Conclusion: The probability of developing peripheral neuropathies in a large animal model was higher

  7. The effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Yeliz Yilmaz

    2016-08-01

    Conclusion: Preoperative Lugol solution treatment was found to be a significant independent determinant of intraoperative blood loss. Moreover, preoperative Lugol solution treatment decreased the rate of blood flow, and intraoperative blood loss during thyroidectomy.

  8. Show Me the Green

    Science.gov (United States)

    Norbury, Keith

    2013-01-01

    Gone are the days when green campus initiatives were a balm to the soul and a drain on the wallet. Today's environmental initiatives are all about saving lots of green--in every sense of the word. The environmental benefits of green campus projects--whether wind turbines or better insulation--are pretty clear. Unfortunately, in today's…

  9. Green roof Malta

    OpenAIRE

    Gatt, Antoine

    2015-01-01

    In Malta, buildings cover one third of the Island, leaving greenery in the dirt track. Green roofs are one way to bring plants back to urban areas with loads of benefits. Antoine Gatt, who manages the LifeMedGreenRoof project at the University of Malta, tells us more. http://www.um.edu.mt/think/green-roof-malta/

  10. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  11. In the Green

    Science.gov (United States)

    Kennedy, Mike

    2011-01-01

    Education officials used to debate whether they could afford to pursue green design and construction. Now the green movement has gained a foothold not just in education, but in society at large, and the prevailing attitude seems to have shifted. Can schools afford "not" to go green? As budgets are slashed repeatedly, education administrators must…

  12. The green agenda

    CERN Document Server

    Calder, Alan

    2009-01-01

    This business guide to Green IT was written to introduce, to a business audience, the opposing groups and the key climate change concepts, to provide an overview of a Green IT strategy and to set out a straightforward, bottom line-orientated Green IT action plan.

  13. The Green Man

    Science.gov (United States)

    Watson-Newlin, Karen

    2010-01-01

    The Jolly Green Giant. Robin Hood. The Bamberg Cathedral. Tales of King Arthur. Ecology. What do they have in common? What legends and ancient myths are shrouded in the tales of the Green Man? Most often perceived as an ancient Celtic symbol as the god of spring and summer, the Green Man disappears and returns year after year, century after…

  14. INTRAOPERATIVE IRRADIATION OF THE CANINE PANCREAS - SHORT-TERM EFFECTS

    NARCIS (Netherlands)

    HEIJMANS, HJ; MEHTA, DM; KLEIBEUKER, JH; SLUITER, WJ; OLDHOFF, J; HOEKSTRA, HJ

    1993-01-01

    Intraoperative electron beam radiotherapy (IORT) is clinically used as a potential adjunctive treatment to surgery of locally advanced pancreatic and gastric cancer. The tolerance of the pancreas to IORT was studied in 15 adult beagles, divided in 3 groups of 5 beagles in which 25, 30 or 35 Gy IORT

  15. Intraoperative cell salvage in South Africa: Feasible, beneficial and ...

    African Journals Online (AJOL)

    More than one CS blood unit was available for transfusion in 66% of cases. No additional staff were required to operate the Cell Saver, which was successfully used by medical officers. Conclusions. This study showed that intraoperative CS use is feasible, has potential patient benefit by reducing blood bank blood ...

  16. Intraoperative Death During Cervical Spinal Surgery: A Retrospective Multicenter Study.

    Science.gov (United States)

    Wang, Jeffrey C; Buser, Zorica; Fish, David E; Lord, Elizabeth L; Roe, Allison K; Chatterjee, Dhananjay; Gee, Erica L; Mayer, Erik N; Yanez, Marisa Y; McBride, Owen J; Cha, Peter I; Arnold, Paul M; Fehlings, Michael G; Mroz, Thomas E; Riew, K Daniel

    2017-04-01

    A retrospective multicenter study. Routine cervical spine surgeries are typically associated with low complication rates, but serious complications can occur. Intraoperative death is a very rare complication and there is no literature on its incidence. The purpose of this study was to determine the intraoperative mortality rates and associated risk factors in patients undergoing cervical spine surgery. Twenty-one surgical centers from the AOSpine North America Clinical Research Network participated in the study. Medical records of patients who received cervical spine surgery from January 1, 2005, to December 31, 2011, were reviewed to identify occurrence of intraoperative death. A total of 258 patients across 21 centers met the inclusion criteria. Most of the surgeries were done using the anterior approach (53.9%), followed by posterior (39.1%) and circumferential (7%). Average patient age was 57.1 ± 13.2 years, and there were more male patients (54.7% male and 45.3% female). There was no case of intraoperative death. Death during cervical spine surgery is a very rare complication. In our multicenter study, there was a 0% mortality rate. Using an adequate surgical approach for patient diagnosis and comorbidities may be the reason how the occurrence of this catastrophic adverse event was prevented in our patient population.

  17. Intraoperative colonic irrigation in the management of left sided ...

    African Journals Online (AJOL)

    Objectives: To evaluate the safety and benefits of antegrade intraoperative colonic irrigation (lavage) and primary anastomosis, after colonic resection, in the treatment of left sided large bowel emergencies. Design: A prospective descriptive study. Setting: Jos University Teaching Hospital, Jos, Nigeria. Participants: Thirty ...

  18. Fusion of intraoperative force sensoring, surface reconstruction and biomechanical modeling

    Science.gov (United States)

    Röhl, S.; Bodenstedt, S.; Küderle, C.; Suwelack, S.; Kenngott, H.; Müller-Stich, B. P.; Dillmann, R.; Speidel, S.

    2012-02-01

    Minimally invasive surgery is medically complex and can heavily benefit from computer assistance. One way to help the surgeon is to integrate preoperative planning data into the surgical workflow. This information can be represented as a customized preoperative model of the surgical site. To use it intraoperatively, it has to be updated during the intervention due to the constantly changing environment. Hence, intraoperative sensor data has to be acquired and registered with the preoperative model. Haptic information which could complement the visual sensor data is still not established. In addition, biomechanical modeling of the surgical site can help in reflecting the changes which cannot be captured by intraoperative sensors. We present a setting where a force sensor is integrated into a laparoscopic instrument. In a test scenario using a silicone liver phantom, we register the measured forces with a reconstructed surface model from stereo endoscopic images and a finite element model. The endoscope, the instrument and the liver phantom are tracked with a Polaris optical tracking system. By fusing this information, we can transfer the deformation onto the finite element model. The purpose of this setting is to demonstrate the principles needed and the methods developed for intraoperative sensor data fusion. One emphasis lies on the calibration of the force sensor with the instrument and first experiments with soft tissue. We also present our solution and first results concerning the integration of the force sensor as well as accuracy to the fusion of force measurements, surface reconstruction and biomechanical modeling.

  19. Pre- and intraoperative volume determination of craniopharyngioma cysts

    Energy Technology Data Exchange (ETDEWEB)

    Georgi, P.; Strauss, L.; Sturm, V.; Ostertag, H.; Sinn, H.; Rommel, T.

    1980-08-01

    Exact cystic volume measurement is a prerequisite to proper /sup 90/Y dosage in the therapy of intracavitary monocystic craniopharyngiomas. The method of intraoperative volume measurement by a radionuclide dilution technique is compared to results abtained by preoperative using computer tomography. Both methods gave congruous results. It is pointed out that gamma camera scintigrams are essential for the early detection of complications.

  20. Appropriateness of Intra-Operative Blood Transfusion In Children at ...

    African Journals Online (AJOL)

    Background: The decision to transfuse intra-operatively is based on preoperative haemoglobin (Hb), estimated blood loss and physiological variables. The visual estimate of blood loss is notoriously unreliable especially with small volumes of blood losses in children. Objectives :We sought therefore to determine the ...

  1. The diagnostic dilemma of intraoperative hyperpyrexia in a malaria ...

    African Journals Online (AJOL)

    Keywords: Intraoperative fever, Malaria, Malignant hyperthermia. ... paludisme devront être examiné et soigné de paludisme s'il est indiqué d'une manière préopératoire même s'il est ... West African Journal of Medicine Vol.22(1) 2003: 98-100 ...

  2. Video-rate optical flow corrected intraoperative functional fluorescence imaging

    NARCIS (Netherlands)

    Koch, Maximilian; Glatz, Juergen; Ermolayev, Vladimir; de Vries, Elisabeth G. E.; van Dam, Gooitzen M.; Englmeier, Karl-Hans; Ntziachristos, Vasilis

    Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and

  3. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  4. Intraoperative glucose management in children < 1 year or < 10 kg ...

    African Journals Online (AJOL)

    The intraoperative management of intravenous dextrose administration and blood glucose monitoring was at the discretion of the attending anaesthetists. Data collected included patient demographics, period of starvation, dose of dextrose administered and blood glucose measurements taken. Results: Nine infants had at ...

  5. Intraoperative Deaths at Ahmadu Bello University Teaching Hospital ...

    African Journals Online (AJOL)

    Nine cases of intraoperative deaths were recorded. Most of the deaths occurred among the gravely ill, inadequately prepared patients and patients whose operations were done in the late hours of the night. Conclusion: This tragedy is preventable by paying meticulous attention to details and careful patient selection and ...

  6. Comparative Study Of Intra-Operative Pelvimetry With Calipers And ...

    African Journals Online (AJOL)

    The pelvic measurement of patients who have had a caesarean section was done using Pelvic Calipers (intra-operative) and x-ray methods. In the former method, during Caesarean sections and after closure of the lower uterine segment incision, a pair of pelvic calipers was used to measure the true conjugate of the pelvis.

  7. Medical Error Avoidance in Intraoperative Neurophysiological Monitoring: The Communication Imperative.

    Science.gov (United States)

    Skinner, Stan; Holdefer, Robert; McAuliffe, John J; Sala, Francesco

    2017-11-01

    Error avoidance in medicine follows similar rules that apply within the design and operation of other complex systems. The error-reduction concepts that best fit the conduct of testing during intraoperative neuromonitoring are forgiving design (reversibility of signal loss to avoid/prevent injury) and system redundancy (reduction of false reports by the multiplication of the error rate of tests independently assessing the same structure). However, error reduction in intraoperative neuromonitoring is complicated by the dichotomous roles (and biases) of the neurophysiologist (test recording and interpretation) and surgeon (intervention). This "interventional cascade" can be given as follows: test → interpretation → communication → intervention → outcome. Observational and controlled trials within operating rooms demonstrate that optimized communication, collaboration, and situational awareness result in fewer errors. Well-functioning operating room collaboration depends on familiarity and trust among colleagues. Checklists represent one method to initially enhance communication and avoid obvious errors. All intraoperative neuromonitoring supervisors should strive to use sufficient means to secure situational awareness and trusted communication/collaboration. Face-to-face audiovisual teleconnections may help repair deficiencies when a particular practice model disallows personal operating room availability. All supervising intraoperative neurophysiologists need to reject an insular or deferential or distant mindset.

  8. Intra-operative parathyroid hormone measurements – experience of ...

    African Journals Online (AJOL)

    Background. Surgery is the treatment of choice for symptomatic primary hyperparathyroidism. The majority of research concerning intra-operative parathyroid hormone (ioPTH) measurements is conducted in university hospitals. Whether ioPTH measurements are feasible and useful in predicting the presence of remaining ...

  9. Green Transformational Leadership and Green Performance: The Mediation Effects of Green Mindfulness and Green Self-Efficacy

    OpenAIRE

    Yu-Shan Chen; Ching-Hsun Chang; Yu-Hsien Lin

    2014-01-01

    No prior literature explores the influence of green transformational leadership on green performance, thus, this study develops a novel research framework to fill the research gap. This study investigates the influence of green transformational leadership on green performance and discusses the mediation effects of green mindfulness and green self-efficacy by means of structural equation modeling (SEM). The results indicate that green transformational leadership positively influences green min...

  10. Physics-based shape matching for intraoperative image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Suwelack, Stefan, E-mail: suwelack@kit.edu; Röhl, Sebastian; Bodenstedt, Sebastian; Reichard, Daniel; Dillmann, Rüdiger; Speidel, Stefanie [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology, Adenauerring 2, Karlsruhe 76131 (Germany); Santos, Thiago dos; Maier-Hein, Lena [Computer-assisted Interventions, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany); Wagner, Martin; Wünscher, Josephine; Kenngott, Hannes; Müller, Beat P. [General, Visceral and Transplantation Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 110, Heidelberg 69120 (Germany)

    2014-11-01

    Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intraoperative surface has to be matched to the preoperative model. The shape matching is especially challenging in the intraoperative setting due to noisy sensor data, only partially visible surfaces, ambiguous shape descriptors, and real-time requirements. Methods: A novel physics-based shape matching (PBSM) approach to register intraoperatively acquired surface meshes to preoperative planning data is proposed. The key idea of the method is to describe the nonrigid registration process as an electrostatic–elastic problem, where an elastic body (preoperative model) that is electrically charged slides into an oppositely charged rigid shape (intraoperative surface). It is shown that the corresponding energy functional can be efficiently solved using the finite element (FE) method. It is also demonstrated how PBSM can be combined with rigid registration schemes for robust nonrigid registration of arbitrarily aligned surfaces. Furthermore, it is shown how the approach can be combined with landmark based methods and outline its application to image guidance in laparoscopic interventions. Results: A profound analysis of the PBSM scheme based on in silico and phantom data is presented. Simulation studies on several liver models show that the approach is robust to the initial rigid registration and to parameter variations. The studies also reveal that the method achieves submillimeter registration accuracy (mean error between 0.32 and 0.46 mm). An unoptimized, single core implementation of the approach achieves near real-time performance (2 TPS, 7–19 s total registration time). It outperforms established methods in terms of speed and accuracy. Furthermore, it is shown that the

  11. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    Science.gov (United States)

    Lee, Su-Keon; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondylolisthesis on lumbar lordosis after an intraoperative prone position. Methods Sixty-seven patients, who underwent spinal fusion at the Department of Orthopaedic Surgery of Gwangmyeong Sungae Hospital between May 2007 and February 2012, were included in this study. The study compared lumbar lordosis on preoperative upright, intraoperative prone and postoperative upright lateral X-rays between the simple stenosis (SS) group and spondylolisthesis group. The average age of patients was 67.86 years old. The average preoperative lordosis was 43.5° (± 14.9°), average intraoperative lordosis was 48.8° (± 13.2°), average postoperative lordosis was 46.5° (± 16.1°) and the average change on the frame was 5.3° (± 10.6°). Results Among all patients, 24 patients were diagnosed with simple spinal stenosis, 43 patients with spondylolisthesis (29 degenerative spondylolisthesis and 14 isthmic spondylolisthesis). Between the SS group and spondylolisthesis group, preoperative lordosis, intraoperative lordosis and postoperative lordosis were significantly larger in the spondylolisthesis group. The ratio of patients with increased lordosis on the OSI frame compared to preoperative lordosis was significantly higher in the spondylolisthesis group. The risk of increased lordosis on frame was significantly higher in the spondylolisthesis group (odds ratio, 3.325; 95% confidence interval, 1.101 to 10.039; p = 0.033). Conclusions Intraoperative lumbar lordosis on the OSI frame with a prone

  12. Categorization of intraoperative ureteroscopy complications using modified Satava classification system.

    Science.gov (United States)

    Tepeler, Abdulkadir; Resorlu, Berkan; Sahin, Tolga; Sarikaya, Selcuk; Bayindir, Mirze; Oguz, Ural; Armagan, Abdullah; Unsal, Ali

    2014-02-01

    To review our experience with ureteroscopy (URS) in the treatment of ureteral calculi and stratify intraoperative complications of URS according to the modified Satava classification system. We performed a retrospective analysis of 1,208 patients (672 males and 536 females), with a mean age of 43.1 years (range 1-78), who underwent ureteroscopic procedures for removal of ureteral stones. Intraoperative complications were recorded according to modified Satava classification system. Grade 1 complications included incidents without consequences for the patient; grade 2 complications, which are treated intraoperatively with endoscopic surgery (grade 2a) or required endoscopic re-treatment (grade 2b); and grade 3 complications included incidents requiring open or laparoscopic surgery. The stones were completely removed in 1,067 (88.3%) patients after primary procedure by either simple extraction or after fragmentation. The overall incidence of intraoperative complications was 12.6%. The most common complications were proximal stone migration (3.9%), mucosal injury (2.8%), bleeding (1.9%), inability to reach stone (1.8%), malfunctioning or breakage of instruments (0.8%), ureteral perforation (0.8%) and ureteral avulsion (0.16%). According to modified Satava classification system, there were 4.5% grade 1; 4.4% grade 2a; 3.2% grade 2b; and 0.57% grade 3 complications. We think that modified Satava classification is a quick and simple system for describing the severity of intraoperative URS complications and this grading system will facilitate a better comparison for the surgical outcomes obtained from different centers.

  13. Intraoperative and Early Postoperative Complications of Manual Sutureless Cataract Extraction

    International Nuclear Information System (INIS)

    Iqbal, Y.; Zia, S.; Mirza, A. B.

    2014-01-01

    Objective: To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Study Design: Case series. Place and Duration of Study: Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Methodology: Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Results: Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Conclusion: Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema. (author)

  14. Green Thunderstorms Observed.

    Science.gov (United States)

    Gallagher, Frank W., III; Beasley, William H.; Bohren, Craig F.

    1996-12-01

    Green thunderstorms have been observed from time to time in association with deep convection or severe weather events. Often the green coloration has been attributed to hail or to reflections of light from green foliage on the ground. Some skeptics who have not personally observed a green thunderstorm do not believe that green thunderstorms exist. They suggest that the green storms may be fabrications by excited observers. The authors have demonstrated the existence of green thunderstorms objectively using a spectrophotometer. During the spring and summer of 1995 the authors observed numerous storms and recorded hundreds of spectra of the light emanating corn these storms. It was found that the subjective judgment of colors can vary somewhat between observers, but the variation is usually in the shade of green. The authors recorded spectra of green and nongreen thunderstorms and recorded spectral measurements as a storm changed its appearance from dark blue to a bluish green. The change in color is gradual when observed from a stationary position. Also, as the light from a storm becomes greener, the luminance decreases. The authors also observed and recorded the spectrum of a thunderstorm during a period of several hours as they flew in an aircraft close to a supercell that appeared somewhat green. The authors' observations refute the ground reflection hypothesis and raise questions about explanations that require the presence of hail.

  15. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve : Histopathological and morphometric studies

    NARCIS (Netherlands)

    Vujaskovic, Z; Powers, BE; Paardekoper, G; Gillette, SM; Gillette, EL; Colacchio, TA

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate

  16. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis

    DEFF Research Database (Denmark)

    Pind, Marie-Louise Lindberg; Bendtsen, Flemming; Kallemose, Thomas

    2016-01-01

    BACKGROUND AND AIMS: Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands...... as a noninvasive predictor of portal hypertension. METHODS: A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. RESULTS: Assessment of the diagnostic performance of ICG clearance and ICG-r15...... significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. CONCLUSION: ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15...

  17. GREEN MANAGEMENT: THE REALITY OF BEING GREEN IN BUSINESS

    OpenAIRE

    Tran, Ben

    2009-01-01

    Green management and going green are not as clear cut and easy as hyped by the general media. While going ecologically green is indeed beneficial and appropriate, the process and procedure of becoming green is anything but easy. Firstly, turning green is largely not a legal requirement, but a voluntary process. Thus, even though LEED (which is by far the more publicly known green certification standard) governs the certification of the green management effort, it is not a compulsory condition...

  18. Intraoperative and external beam radiotherapy for pancreatic carcinoma; Intraoperative und perkutane Radiotherapie des Pankreaskarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Eble, M.J. [Abt. Klinische Radiologie, Radiologische Universitaetsklinik Heidelberg (Germany); Maurer, U. [Klinikum der Stadt Mannheim (Germany). Inst. fuer Radiologie

    1996-05-01

    Therapeutic strategies in the treatment of pancreatic carcinoma are based on the high number of non-resectable cancers, the high relative radioresistance and the high distant metastases rate. Even in curatively resected carcinomas, a locally effective treatment modality is needed because of the risk of microscopical residual disease in the peripancreatic tissue. The efficacy of radiotherapy is dose dependent. Based on an analysis of published data a dose of more than 50 Gy is recommended, resulting in a high morbidity rate with external beam radiotherapy alone. The use of intraoperative radiotherapy allows locally restricted dose escalation without increased perioperative morbidity. In adjuvant and in primary treatment, local tumor control was improved (70-90%). With palliative intent, pain relief was obtained rapidly in over 60% of patients and led to improved patient performance. As a result of the high distant metastases rate, even in curatively resected carcinomas, the overall prognosis could not be significantly improved. Further dose escalation is limited by the increasing incidence of upper gastrointestinal bleeding (20-30%). (orig.) [Deutsch] Therapiestrategien beim Pankreaskarzinom werden bestimmt durch den hohen Anteil primaer nicht resektabler Karzinome, der hohen relativen Strahlenresistenz und der hohen Fernmetastasierungsrate. Selbst kurativ resezierte Karzinome erfordern durch ihre hohe lokale Tumorzellpersistenz eine lokal effektive adjuvante Behandlungsmassnahme. Die Effektivitaet einer Radiotherapie ist dosisabhaengig. Aus der Analyse publizierter Daten wird eine Dosis von >50 Gy, welche bei der alleinigen perkutanen Bestrahlung mit einer hohen Morbiditaet verbunden ist, empfohlen. Mit der intraoperativen Radiotherapie ist eine lokal begrenzte Dosiseskalation ohne erhoehte perioperative Morbiditaet moeglich. Sowohl in der adjuvanten als auch in der primaeren Behandlung kann die lokale Tumorkontrolle deutlich verbessert werden (70-90%). Unter

  19. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    International Nuclear Information System (INIS)

    Sty, J.; Simons, G.

    1982-01-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success

  20. Intraoperative language localization in multilingual patients with gliomas.

    Science.gov (United States)

    Bello, Lorenzo; Acerbi, Francesco; Giussani, Carlo; Baratta, Pietro; Taccone, Paolo; Songa, Valeria; Fava, Marica; Stocchetti, Nino; Papagno, Costanza; Gaini, Sergio M

    2006-07-01

    Intraoperative localization of speech is problematic in patients who are fluent in different languages. Previous studies have generated various results depending on the series of patients studied, the type of language, and the sensitivity of the tasks applied. It is not clear whether languages are mediated by multiple and separate cortical areas or shared by common areas. Globally considered, previous studies recommended performing a multiple intraoperative mapping for all the languages in which the patient is fluent. The aim of this work was to study the feasibility of performing an intraoperative multiple language mapping in a group of multilingual patients with a glioma undergoing awake craniotomy for tumor removal and to describe the intraoperative cortical and subcortical findings in the area of craniotomy, with the final goal to maximally preserve patients' functional language. Seven late, highly proficient multilingual patients with a left frontal glioma were submitted preoperatively to a battery of tests to evaluate oral language production, comprehension, and repetition. Each language was tested serially starting from the first acquired language. Items that were correctly named during these tests were used to build personalized blocks to be used intraoperatively. Language mapping was undertaken during awake craniotomies by the use of an Ojemann cortical stimulator during counting and oral naming tasks. Subcortical stimulation by using the same current threshold was applied during tumor resection, in a back and forth fashion, and the same tests. Cortical sites essential for oral naming were found in 87.5% of patients, those for the first acquired language in one to four sites, those for the other languages in one to three sites. Sites for each language were distinct and separate. Number and location of sites were not predictable, being randomly and widely distributed in the cortex around or less frequently over the tumor area. Subcortical stimulations found

  1. Green energy in Europe: selling green energy with green certificates

    International Nuclear Information System (INIS)

    Ouillet, L.

    2002-01-01

    Sales of green power products are booming in Europe: 50,000 customers in the United Kingdom, 775,000 in the Netherlands and 300,000 in Germany. Laws of physics are however formal: the way in which electricity flows within the grid does not allow suppliers to assure customers that they are directly receiving electricity produced exclusively from renewable energy sources. What are marketers selling their customers then? Laetitia Ouillet, Greenprices, takes a closer look and focuses on the potential of selling green energy in the forms of renewable energy certificates. (Author)

  2. Green growth in fisheries

    DEFF Research Database (Denmark)

    Nielsen, Max; Ravensbeck, Lars; Nielsen, Rasmus

    2014-01-01

    harming the environment. Fishery is an environment-dependent sector and it has been argued that there is no potential for green growth in the sector owing to global overexploitation, leaving no scope for production growth. The purpose of this paper is to explain what green growth is and to develop......Climate change and economic growth have gained a substantial amount of attention over the last decade. Hence, in order to unite the two fields of interest, the concept of green growth has evolved. The concept of green growth focuses on how to achieve growth in environment-dependent sectors, without...... a conceptual framework. Furthermore, the aim is to show that a large green growth potential actually exists in fisheries and to show how this potential can be achieved. The potential green growth appears as value-added instead of production growth. The potential can be achieved by reducing overcapacity...

  3. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  4. Principles for Management of Intraoperative Acute Type A Aortic Dissection.

    Science.gov (United States)

    Gukop, Philemon; Chandrasekaran, Vankatachalam

    2015-12-01

    Intraoperative Type A aortic dissection is a rare pathology with incidence of 0.06-0.32%. It is associated with a high mortality between 30-50%. Some associated risk factors, including hypertension, enlarged aorta, peripheral vascular disease, advanced age, atheroma, and high arterial pressure on cardiopulmonary bypass, have been identified. Modification of these risk factors could reduce the incidence of this event. Prompt diagnosis and management, with the aid of intraoperative trans-esophageal echocardiography and/or epi-aortic ultrasound has been shown to reduce the mortality to 17%. We illustrate the principles of management of this pathology with the case of a 62-year-old female who developed acute Type A aortic dissection while undergoing minimally invasive mitral valve repair.

  5. Transsphenoidal pituitary resection with intraoperative MR guidance: preliminary results

    Science.gov (United States)

    Pergolizzi, Richard S., Jr.; Schwartz, Richard B.; Hsu, Liangge; Wong, Terence Z.; Black, Peter M.; Martin, Claudia; Jolesz, Ferenc A.

    1999-05-01

    The use of intraoperative MR image guidance has the potential to improve the precision, extent and safety of transsphenoidal pituitary resections. At Brigham and Women's Hospital, an open-bore configuration 0.5T MR system (SIGNA SP, GE Medical Systems, Milwaukee, WI) has been used to provide image guidance for nine transsphenoidal pituitary adenoma resections. The intraoperative MR system allowed the radiologist to direct the surgeon toward the sella turcica successfully while avoiding the cavernous sinus, optic chiasm and other sensitive structures. Imaging performed during the surgery monitored the extent of resection and allowed for removal of tumor beyond the surgeon's view in five cases. Dynamic MR imaging was used to distinguish residual tumor from normal gland and postoperative changes permitting more precise tumor localization. A heme-sensitive long TE gradient echo sequence was used to evaluate for the presence of hemorrhagic debris. All patients tolerated the procedure well without significant complications.

  6. Intraoperative Functional Mapping and Monitoring during Glioma Surgery

    Science.gov (United States)

    SAITO, Taiichi; MURAGAKI, Yoshihiro; MARUYAMA, Takashi; TAMURA, Manabu; NITTA, Masayuki; OKADA, Yoshikazu

    2015-01-01

    Glioma surgery represents a significant advance with respect to improving resection rates using new surgical techniques, including intraoperative functional mapping, monitoring, and imaging. Functional mapping under awake craniotomy can be used to detect individual eloquent tissues of speech and/or motor functions in order to prevent unexpected deficits and promote extensive resection. In addition, monitoring the patient’s neurological findings during resection is also very useful for maximizing the removal rate and minimizing deficits by alarming that the touched area is close to eloquent regions and fibers. Assessing several types of evoked potentials, including motor evoked potentials (MEPs), sensory evoked potentials (SEPs) and visual evoked potentials (VEPs), is also helpful for performing surgical monitoring in patients under general anesthesia (GA). We herein review the utility of intraoperative mapping and monitoring the assessment of neurological findings, with a particular focus on speech and the motor function, in patients undergoing glioma surgery. PMID:25744346

  7. A meta-analysis of intraoperative factors associated with ...

    African Journals Online (AJOL)

    ... 95% 1.9-26), new onset atrial fibrillation (OR 6.6, 95% CI 2.5-20), hypothermia (OR 2.2, 95% CI 1.1-5) and remote ischaemic preconditioning (OR 0.22, 95% CI 0.07-0.67). None of these studies controlled for blood transfusion. Conclusion: Both surgical and haemodynamic intraoperative events significantly increased the ...

  8. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    OpenAIRE

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intra...

  9. Recurrent intraoperative silent ST depression responding to phenylephrine

    Directory of Open Access Journals (Sweden)

    P M Singh

    2012-01-01

    Full Text Available Intraoperative myocardial ischemia is attributed to decreased myocardial oxygen supply. We present an unusual case of recurrent, symptomless inferior wall ischemia in an apparently healthy male with no history of coronary artery disease after a spinal block. The recurring episodes were linked to tachycardia and presented with significant ST depression in Lead II with reciprocal elevation in lead aVL. The episodes responded to phenylephrine and subsided without residual sequelae.

  10. Premedication with oral Dextromethorphan reduces intra-operative Morphine requirement

    Directory of Open Access Journals (Sweden)

    R Talakoub

    2005-09-01

    Full Text Available Background: Intra-operative pain has adverse effects on hemodynamic parameters. Due to complications of opioids for pain relief, using non-opioids medication is preferred. The purpose of this study was to investigate the effect of oral dextrometorphan premedication on intra-operative Morphine requirement. Methods: After approval of the Ethics committee and informed consent, 40 adult patients who stand in American Society of Anesthesiologists Physical Status I and II, under general anesthesia for elective laparatomy were selected and classified in two equal groups randomly. In group A, oral dextromethorphan (60mg was administered at 10 PM and 6 AM preoperatively. In group B, placebo (dextrose was administered. After induction of general anesthesia and before skin incision, intravenous morphine (0.01 mg/kg was administered. During surgery, when systolic blood pressure or heart rate was increased more than 20% of the preoperative baseline, 0.01 mg/kg morphine was administered. At the end of surgery, the totally prescribed morphine (mg/kg and maximal increase in systolic, diastolic, mean arterial blood pressure and heart rate relative to the baseline values were calculated and statistically compared with student’s t-test. Results: The mean dose of administered morphine during surgery was significantly less in group A than group B (P<0.0001. Also, Maximal increase in systolic, diastolic and mean arterial blood pressure was significantly less in group A (p<0.003, p<0.004, p<0.0001, respectively. There was no significant difference in maximal heart rate increase between two groups (p<0.114. Conclusion: Oral dextromethorphan premedication may decrease intra-operative morphine requirement and reduce maximal increase in systolic and mean arterial blood pressure during surgery. Key words: Dextromethorphan, Morphine, Intra-operative, Premedication Hemodynamic

  11. Intraoperative tractography and neuronavigation of the pyramidal tract

    International Nuclear Information System (INIS)

    Nimsky, C.; Ganslandt, O.; Weigel, D.; Keller, B. von; Stadlbauer, A.; Akutsu, H.; Hammen, T.; Buchfelder, M.

    2008-01-01

    Diffusion tensor imaging (DTI) based fiber tracking was applied to visualize the course of the pyramidal tract in the surgical field by microscope-based navigation. In 70 patients with lesions adjacent to the pyramidal tract, DTI data were integrated in a navigational setup. Diffusion data (b=0) were rigidly registered with standard T1-weighted 3-D images. Fiber tracking was performed applying a tensor-deflection algorithm using a multiple volume of interest approach as seed regions for tracking. fMRI data identifying the motor gyrus were applied as selection criteria to define the fibers of interest. After tracking, a 3-D object was generated representing the pyramidal tract. In selected cases, the intraoperative image data (1.5 T intraoperative MRI) were used to update the navigation system. In all patients the pyramidal tract could be visualized in the operative field applying the heads-up display of the operating microscope. In 8 patients (11%) a new or aggravated postoperative paresis could be observed, which was transient in 5 of them; thus, only in 3 patients (4.2%) was there a new permanent neurological deficit. Intraoperative imaging depicted a shifting of the pyramidal tract which amounted up to 15 mm; even the direction of shifting was variable and could not be predicted before surgery, so that mathematical models trying to predict brain shift behaviour are of restricted value only. DTI fiber tracking data can be reliably integrated into navigational systems providing intraoperative visualization of the pyramidal tract. This technique allowed the resection of lesions adjacent to the pyramidal tract with low morbidity. (author)

  12. Dapsone Induced Methaemoglobinemia: Early Intraoperative Detection by Pulse Oximeter Desaturation

    Directory of Open Access Journals (Sweden)

    Mahmood Rafiq

    2008-01-01

    Case signifies the importance of knowledge of any preoperative drug intake and its anaesthetic implications. Also patients on dapsone therapy especially children should be monitored for methaemoglobin levels. Since children with immune thrombocy-topenic purpura are being treated with dapsone these days and many of these patients would be planned for splenectomy, monitoring of preoperative methaemoglobin levels and methaemoglobinemia as a cause of intraoperative pulse oximeter desaturation should be kept in mind.

  13. Intraoperative radionuclide study and colonoscopy in gastrointestinal hemorrhage

    International Nuclear Information System (INIS)

    Navab, F.; Westbrook, K.C.; Slaton, G.; Boyd, C.M.

    1985-01-01

    Tc-99m labeled red cell imaging is used in the diagnosis and localization of gastrointestinal hemorrhage. A patient in whom a preoperative scan was positive in the right paraumbilical region is discussed. Intraoperative Tc-99m labeled red cell imaging was used in conjunction with colonoscopy, and the site of active bleeding was found in the proximal transverse colon, which had been displaced downward because of adhesions

  14. Green electricity buyer's guide

    International Nuclear Information System (INIS)

    Kelly, B.; Klein, S.; Olivastri, B.

    2002-06-01

    The electricity produced in whole or in large part from renewable energy sources like wind, small hydro electricity and solar energy, is generally referred to as green electricity. The authors designed this buyer's guide to assist customers in their understanding of green electricity, as the customers can now choose their electricity supplier. The considerations and steps involved in the purchasse of green electricity are identified, and advice is provided on ways to maximize the benefits from the purchase of green electricity. In Alberta and Ontario, customers have access to a competitive electricity market. The emphasis when developing this guide was placed firmly on the large buyers, as they can have enormous positive influence on the new market for green electricity. The first chapter of the document provides general information on green electricity. In chapter two, the authors explore the opportunity for environmental leadership. Chapter three reviews the basics of green electricity, which provides the link to chapter four dealing with the creation of a policy. Purchasing green electricity is dealt with in Chapter five, and maximizing the benefits of green electricity are examined in Chapter Six. 24 refs., 3 tabs

  15. GREEN PACKAGING, GREEN PRODUCT, GREEN ADVERTISING, PERSEPSI, DAN MINAT BELI KONSUMEN

    OpenAIRE

    Imam Santoso; Rengganis Fitriani

    2016-01-01

    Environmental problems become one of the strategic issues in achieving global competitiveness. One of the issues is products that are made from environmental friendly materials or known as green product. Furthermore, in green products marketing, the company also uses green packaging and green advertising concept. This study aimed to analyze the effect of green packaging, green products, and green advertising on consumer perception and purchasing intention. The study was conducted in Ketawangg...

  16. Intraoperative perception and sensation in laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Srivannaboon, Sabong; Chansue, Ekktet

    2004-04-01

    To investigate intraoperative perception and sensation during Laser in situ Keratomileusis (LASIK). Sixty patients with uneventful LASIK were included. All procedures were performed by one surgeon with one technique. Any patient with intra-operative complications was excluded. The patients were asked to fill in the subjective evaluation form regarding their perception and sensation during the operation. Twenty-nine patients (48%) reported no pain and twenty-six patients (43%) reported no burning sensation during the surgery. Nineteen patients (32%) reported no light perception during the suction period of microkeratome. There was no correlation between duration of the suction and no light perception (R2 0.01). Thirty-four patients (56%) reported no trouble in maintaining visual fixation at the red light during the laser treatment. Ten patients (16%) reported they could clearly see the movement during the surgery and 5 out of 10 patients (50% of 16%) reported visual frightening. Fifty cases (84%) reported no visual frightening during the surgery after reassurance of the visual experience by the surgeon before the surgery. Patients undergoing LASIK may experience different visual perceptions. Reassurance of the intraoperative perception and sensation before the surgery can reduce the visual frightening.

  17. Intraoperative Cerebral Glioma Characterization with Contrast Enhanced Ultrasound

    Directory of Open Access Journals (Sweden)

    Francesco Prada

    2014-01-01

    Full Text Available Background. Contrast enhanced ultrasound (CEUS is a dynamic and continuous modality providing real-time view of vascularization and flow distribution patterns of different organs and tumors. Nevertheless its intraoperative use for brain tumors visualization has been performed few times, and a thorough characterization of cerebral glioma had never been performed before. Aim. To perform the first characterization of cerebral glioma using CEUS and to possibly achieve an intraoperative differentiation of different gliomas. Methods. We performed CEUS in an off-label setting in 69 patients undergoing surgery for cerebral glioma. An intraoperative qualitative analysis was performed comparing iCEUS with B-mode imaging. A postprocedural semiquantitative analysis was then performed for each case, according to EFSUMB criteria. Results were related to histopathology. Results. We observed different CE patterns: LGG show a mild, dotted CE with diffuse appearance and slower, delayed arterial and venous phase. HGG have a high CE with a more nodular, nonhomogeneous appearance and fast perfusion patterns. Conclusion. Our study characterizes for the first time human brain glioma with CEUS, providing further insight regarding these tumors’ biology. CEUS is a fast, safe, dynamic, real-time, and economic tool that might be helpful during surgery in differentiating malignant and benign gliomas and refining surgical strategy.

  18. SEP Montage Variability Comparison during Intraoperative Neurophysiologic Monitoring.

    Science.gov (United States)

    Hanson, Christine; Lolis, Athena Maria; Beric, Aleksandar

    2016-01-01

    Intraoperative monitoring is performed to provide real-time assessment of the neural structures that can be at risk during spinal surgery. Somatosensory evoked potentials (SEPs) are the most commonly used modality for intraoperative monitoring. SEP stability can be affected by many factors during the surgery. This study is a prospective review of SEP recordings obtained during intraoperative monitoring of instrumented spinal surgeries that were performed for chronic underlying neurologic and neuromuscular conditions, such as scoliosis, myelopathy, and spinal stenosis. We analyzed multiple montages at the baseline, and then followed their development throughout the procedure. Our intention was to examine the stability of the SEP recordings throughout the surgical procedure on multiple montages of cortical SEP recordings, with the goal of identifying the appropriate combination of the least number of montages that gives the highest yield of monitorable surgeries. Our study shows that it is necessary to have multiple montages for SEP recordings, as it reduces the number of non-monitorable cases, improves IOM reliability, and therefore could reduce false positives warnings to the surgeons. Out of all the typical montages available for use, our study has shown that the recording montage Cz-C4/Cz-C3 (Cz-Cc) is the most reliable and stable throughout the procedure and should be the preferred montage followed throughout the surgery.

  19. Intraoperative Hypoglossal Nerve Mapping During Carotid Endarterectomy: Technical Note.

    Science.gov (United States)

    Kojima, Atsuhiro; Saga, Isako; Ishikawa, Mami

    2018-05-01

    Hypoglossal nerve deficit is a possible complication caused by carotid endarterectomy (CEA). The accidental injury of the hypoglossal nerve during surgery is one of the major reasons for permanent hypoglossal nerve palsy. In this study, we investigated the usefulness of intraoperative mapping of the hypoglossal nerve to identify this nerve during CEA. Five consecutive patients who underwent CEA for the treatment of symptomatic or asymptomatic carotid artery stenosis were studied. A hand-held probe was used to detect the hypoglossal nerve in the operative field, and the tongue motor evoked potentials (MEPs) were recorded. The tongue MEPs were obtained in all the patients. The invisible hypoglossal nerve was successfully identified without any difficulty when the internal carotid artery was exposed. Intraoperative mapping was particularly useful for identifying the hypoglossal nerve when the hypoglossal nerve passed beneath the posterior belly of the digastric muscle. In 1 of 2 cases, MEP was also elicited when the ansa cervicalis was stimulated, although the resulting amplitude was much smaller than that obtained by direct stimulation of the hypoglossal nerve. Postoperatively, none of the patients presented with hypoglossal nerve palsy. Intraoperative hypoglossal nerve mapping enabled us to locate the invisible hypoglossal nerve during the exposure of the internal carotid artery accurately without retracting the posterior belly of the digastric muscle and other tissues in the vicinity of the internal carotid artery. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  1. Intraoperative radiotherapy in combined treatment of sinonasal malignant tumors

    Science.gov (United States)

    Novikov, V. A.; Gribova, O. V.; Vasiljev, R. V.; Choynzonov, E. L.; Shtin, V. I.; Shiianova, A. A.; Surkova, P. V.; Starceva, Zh. A.; Shilova, O. G.

    2017-09-01

    Obvious advantage of IORT (intraoperative radiotherapy) is that the radiation source is delivered directly to the bed of the tumor during surgery, thus avoiding the negative impact on the skin, subcutaneous tissue and reducing the risk of fibrosis. Sinonasal tumors—a convenient object for intraoperative radiotherapy application (surface location, relatively small size tumors, good operational access). The surface location and comparatively small size of neoplasms, good operational access provide an efficient and accurate transfer of the electron beam to the postoperative cavity to increase the irradiation dose in the areas of the most probable recurrence, which makes the tumors of this localization a convenient object for the use of the intraoperative radiation therapy. The treatment was conducted using a mobile compact betatron (MIB-6E), 10-12 Gy single dose. IORT session extends surgery period by 30 min. There were no pathological clinical and laboratory reactions on IORT in the early postoperative period. Carrying out the procedure is possible in various standard operating rooms. It does not require special security measures for the patients and the staff. IORT with the help of electron beam allows avoiding post-radiation reactions and achieving a 5-year—disease-free survival of 66% of the patients. IORT session is possible through a minimal incision during organ preservation surgeries. Evident economic feasibility provides the prospects of applying IORT in the clinical practice.

  2. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  3. Dacryocystorhinostomy without intubation with intraoperative mitomycin-c

    International Nuclear Information System (INIS)

    Rahman, A.; Channa, S.; Memon, M.S.; Niazi, J.H.

    2006-01-01

    To evaluate the success rate and complications of intraoperative Mitomycin-C in dacryocystorhinostomy surgery. This study included total 90 eyes of 90 patients fulfilling the inclusion criteria.The surgical procedure of external DCR done with intraoperative Mitomycin-C with a neurosurgical cottonoid soaked with 0.2mg/ml. Mitomycin C was applied to the anastomosed flaps and osteotomy site for 10 minutes, without Silicon tube intubation. Surgery was done under local as well as general anesthesia. Patients were followed for 6 months. Out of 90 patients included in this study, only 2 patients complained of persistent epiphora after 6 months follow-up and were labeled as failed DCR. Remaining 88 had either no tearing or significant improvement of tearing after 6 months follow up and patent lacrimal system by syringing without pressure. Success rate in this procedure was 97.77% (p-value< 0.001). This study showed very high rate of success. Only complication noted was excessive nasal bleeding which was easily controlled. Intraoperative Mitomycin-C application in external DCR is safe, effective, cheap adjunct that helps to achieve good results of DCR surgery. (author)

  4. Intraoperative panoramic image using alignment grid, is it accurate?

    Science.gov (United States)

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  5. Incidence of intraoperative hypothermia: adopting protocol for its prevention

    International Nuclear Information System (INIS)

    Al-Qahtani, Ali S.; Messahel, Farouk M.

    2003-01-01

    To determine the incidence of hypothermia during surgical procedures when adequate methods of preserving normothermia are applied .For this was a study in which patients ASA I-IV presented for surgery at the Armed Forces Hospital, Wadi Al- Dawasir, kingdom of Saudi Arabia ,during the period from July 2000 to February 2003 in whom body core temprature was between 35-37C ,were included. Ambient temperature of the operating room was thermostatically adjusted to record 26C and 24C if patents were < 10 year-old or above .Depending on type of surgery ;the patients were provided with space blankents and were lying on warm mattresses. Fluid or blood warmers and forced-air surface were used when needed for this. = Aggressive measures must be adopted to preserve normothermia as prevention of intraoperative hypothermia improves patients outcome .All patients shoud have their body temprature monitored during surgery .However application of available methods of keeping normothermia reduces the the incidence of intraoperative hypothermia but does not abolish it completely . Hypothermia patients should be closely moniterd during gradual rewarming preferably in the intensive care setting. A protocol for prevention of intraoperative hypothermia must be adopted by all operating theatres. (author)

  6. Intraoperative radiotherapy for the treatment of gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Satomura, Kisaku; Inamoto, Shun; Honda, Kazuo; Takahashi, Masaji [Kyoto Univ. (Japan). Faculty of Medicine

    1982-12-01

    Clinical results of intraoperative radiotherapy for gastric cancer were reported. One hundred and five cases of gastric cancer were treated by intraoperative radiotherapy. Whatever the stage of the patient was, 3-year survival rate was found to be better in the radiotherapy group than that of the control group (treated surgical resection only). Five year survival rate of the stages III and IV in the radiotherapy group was better than the control group. Unfavorable side effects were observed in 4 cases out of 105 cases. In one case, penetration of postoperative peptic ulcer into the irradiated aortic wall was found by autopsy. Two cases of bile duct stenosis and one case of ileus due to acutely developed peritonitis carcinomatosa were experienced. In conclusion, intraoperative radiotherapy immediately after surgical resection for the treatment of gastric cancer was found to be an effective method. The most effective application of the method appears to be to cases of stage II and III without liver metastasis and peritoneal disseminations (H/sub 0/P/sub 0/, M, A).

  7. Intraoperative CT with integrated navigation system in spinal neurosurgery

    International Nuclear Information System (INIS)

    Zausinger, S.; Heigl, T.; Scheder, B.; Schnell, O.; Tonn, J.C.; Uhl, E.; Morhard, D.

    2007-01-01

    For spinal surgery navigational system images are usually acquired before surgery with patients positioned supine. The aim of this study was to evaluate prospectively navigated procedures in spinal surgery with data acquisition by intraoperative computed tomography (iCT). CT data of 38 patients [thoracolumbar instability (n = 24), C1/2 instability (n = 6), cervicothoracic stabilization (n = 7), disk herniation (n = 1)] were acquired after positioning the patient in prone position. A sliding gantry 24 detector row CT was used for image acquisition. Data were imported to the frameless infrared-based neuronavigation station. A postprocedural CT was obtained to assess the extent of decompression and the accuracy of instrumentation. Intraoperative registration revealed computed accuracy 2 mm in 9/158 screws (5.6%), allowing immediate correction in five screws without any damage to vessels or nerves. There were three transient complications with clinical improvement in all patients. Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization. The procedure is rapid and easy to perform and - by replacing pre- and postoperative imaging-is not associated with additional exposure to radiation. (orig.)

  8. Can we trust intraoperative culture results in nonunions?

    Science.gov (United States)

    Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W

    2014-07-01

    To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

  9. An audit of intraoperative frozen section in Johor.

    Science.gov (United States)

    Khoo, J J

    2004-03-01

    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.

  10. Customers’ Intention to Use Green Products: the Impact of Green Brand Dimensions and Green Perceived Value

    Directory of Open Access Journals (Sweden)

    Doszhanov Aibek

    2015-01-01

    Full Text Available This study aimed to identify the relationships between green brand dimension (green brand awareness, green brand image, and green brand trust, green perceived value and customer’s intention to use green products. Data was collected through structured survey questionnaire from 384 customers of three hypermarkets in Kuala-Lumpur. Data was analyzed based on multiple regression analysis. The results indicate that there are significant relationships between green brand awareness, green brand trust, green perceived value, and customer’s intention to use green products. However, green brand image was not found to have significant relationship with customer’s intention to use green products. The discussion presented suggestions for marketers and researchers interested in green branding.

  11. Intraoperative definition of bottom-of-sulcus dysplasia using intraoperative ultrasound and single depth electrode recording - A technical note.

    Science.gov (United States)

    Miller, Dorothea; Carney, Patrick; Archer, John S; Fitt, Gregory J; Jackson, Graeme D; Bulluss, Kristian J

    2018-02-01

    Bottom of sulcus dysplasias (BOSDs) are localized focal cortical dysplasias (FCDs) centred on the bottom of a sulcus that can be highly epileptogenic, but difficult to delineate intraoperatively. We report on a patient with refractory epilepsy due to a BOSD, successfully resected with the aid of a multimodal surgical approach using neuronavigation based on MRI and PET, intraoperative ultrasound (iUS) and electrocorticography (ECoG) using depth electrodes. The lesion could be visualized on iUS showing an increase in echogenicity at the grey-white matter junction. IUS demonstrated the position of the depth electrode in relation to the lesion. Depth electrode recording showed almost continuous spiking. Thus, intraoperative imaging and electrophysiology helped confirm the exact location of the lesion. Post-resection ultrasound demonstrated the extent of the resection and depth electrode recording did not show any epileptiform activity. Thus, both techniques helped assess completeness of resection. The patient has been seizure free since surgery. Using a multimodal approach including iUS and ECoG is a helpful adjunct in surgery for BOSD and may improve seizure outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Greening the Future

    Science.gov (United States)

    Williamson, Norma Velia

    2011-01-01

    Because educators vicariously touch the future through their students, the author believes that they sometimes have the uncanny ability to see the future. One common future forecast is the phenomenal growth of green jobs in the emerging green economy, leading to the creation of the "Reach of the Sun" Solar Energy Academy at La Mirada…

  13. Green Buildings and Health.

    Science.gov (United States)

    Allen, Joseph G; MacNaughton, Piers; Laurent, Jose Guillermo Cedeno; Flanigan, Skye S; Eitland, Erika Sita; Spengler, John D

    2015-09-01

    Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading "Health Performance Indicators" for use in future studies of buildings and health.

  14. Green product innovation strategy

    NARCIS (Netherlands)

    Driessen, P.H.

    2005-01-01

    Over the last decades, companies have started to incorporate green issues in product innovation strategies. This dissertation studies green product innovation strategy, its antecedents and its outcomes. A three-stage approach is followed. In the first stage, the topic is explored and a preliminary

  15. Green for rarity

    International Nuclear Information System (INIS)

    Raal, F.A.; Robinson, D.N.

    1980-01-01

    Green diamonds once recovered from Witwatersrand gold/uranium deposits, are now a thing of the past with the modernisation of extraction metallurgy methods. The green colouration has been shown to be due to radiation from uranium present in the ore

  16. Green Building Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sailor, David Jean [Portland State Univ., Portland, OR (United States)

    2013-12-29

    This project provided support to the Green Building Research Laboratory at Portland State University (PSU) so it could work with researchers and industry to solve technical problems for the benefit of the green building industry. It also helped to facilitate the development of PSU’s undergraduate and graduate-level training in building science across the curriculum.

  17. Green Cleaning Label Power

    Science.gov (United States)

    Balek, Bill

    2012-01-01

    Green cleaning plays a significant and supportive role in helping education institutions meet their sustainability goals. However, identifying cleaning products, supplies and equipment that truly are environmentally preferable can be daunting. The marketplace is inundated with products and services purporting to be "green" or environmentally…

  18. Introduction: Experimental Green Strategies

    DEFF Research Database (Denmark)

    Peters, Terri

    2011-01-01

    Defining new ways in which archietcts are responding to the challenge of creating sustainable architecture , Experimental Green Strategies present a state of the art in applied ecological architectural research.......Defining new ways in which archietcts are responding to the challenge of creating sustainable architecture , Experimental Green Strategies present a state of the art in applied ecological architectural research....

  19. Green heterogeneous wireless networks

    CERN Document Server

    Ismail, Muhammad; Nee, Hans-Peter; Qaraqe, Khalid A; Serpedin, Erchin

    2016-01-01

    This book focuses on the emerging research topic "green (energy efficient) wireless networks" which has drawn huge attention recently from both academia and industry. This topic is highly motivated due to important environmental, financial, and quality-of-experience (QoE) considerations. Specifically, the high energy consumption of the wireless networks manifests in approximately 2% of all CO2 emissions worldwide. This book presents the authors’ visions and solutions for deployment of energy efficient (green) heterogeneous wireless communication networks. The book consists of three major parts. The first part provides an introduction to the "green networks" concept, the second part targets the green multi-homing resource allocation problem, and the third chapter presents a novel deployment of device-to-device (D2D) communications and its successful integration in Heterogeneous Networks (HetNets). The book is novel in that it specifically targets green networking in a heterogeneous wireless medium, which re...

  20. Building the green way.

    Science.gov (United States)

    Lockwood, Charles

    2006-06-01

    Just five or six years ago, the term "green building" evoked visions of barefoot, tie-dyed, granola-munching denizens. There's been a large shift in perception. Of course, green buildings are still known for conserving natural resources by, for example, minimizing on-site grading, using alternative materials, and recycling construction waste. But people now see the financial advantages as well. Well-designed green buildings yield lower utility costs, greater employee productivity, less absenteeism, and stronger attraction and retention of workers than standard buildings do. Green materials, mechanical systems, and furnishings have become more widely available and considerably less expensive than they used to be-often cheaper than their standard counterparts. So building green is no longer a pricey experiment; just about any company can do it on a standard budget by following the ten rules outlined by the author. Reliable building-rating systems like the U.S. Green Building Council's rigorous Leadership in Energy and Environmental Design (LEED) program have done much to underscore the benefits of green construction. LEED evaluates buildings and awards points in several areas, such as water efficiency and indoor environmental quality. Other rating programs include the UK's BREEAM (Building Research Establishment's Environmental Assessment Method) and Australia's Green Star. Green construction is not simply getting more respect; it is rapidly becoming a necessity as corporations push it fully into the mainstream over the next five to ten years. In fact, the author says, the owners of standard buildings face massive obsolescence. To avoid this problem, they should carry out green renovations. Corporations no longer have an excuse for eschewing environmental and economic sustainability. They have at their disposal tools proven to lower overhead costs, improve productivity, and strengthen the bottom line.

  1. Clarkesville Green Infrastructure Implementation Strategy

    Science.gov (United States)

    The report outlines the 2012 technical assistance for Clarkesville, GA to develop a Green Infrastructure Implementation Strategy, which provides the basic building blocks for a green infrastructure plan:

  2. Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy

    Directory of Open Access Journals (Sweden)

    Bub-Se Na

    2017-10-01

    Full Text Available Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for completion pneumonectomy. This case serves as an example of intraoperative recurrent laryngeal nerve monitoring during thoracic surgery and supports this indication for its use.

  3. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  4. Intraoperative HDR implant boost for breast cancer (preliminary results)

    International Nuclear Information System (INIS)

    Rodriguez, I.; Torre, M. de la; Gonzalez, E.; Bourel, V.

    1996-01-01

    Introduction: In spite of the fact that it is been discussed whether or not a boost is necessary for all conservative treated breast cancer patients, it is a generalized radiotherapy practice. Since september 1993 we developed a breast conservative protocol for early stage breast cancer (T1-T2) with intraoperative HDR implant boost. Side effects, cosmetic results and recurrence rates are reviewed. Method and Material: From September 1993 we treated 55 patients with intraoperative HDR implant boost to the lumpectomy site for clinical T1 or T2 invasive breast cancer, followed by external megavoltage radiotherapy to the entire breast. We used the Nucletron microselectron HDR remote afterloading system with flexible implant tubes. The geometric distribution of the tubes was performed according to the 'Paris' configuration. Each implant was evaluated by calculating the dose-volume natural histograms. The HDR fractionation schedule consists of three fractions of 4.5Gy each given at least 48 hs apart, and starting between 48-72hs from surgical procedure. The external radiotherapy to the entire breast started one week after the completion of brachytherapy, using conventional fractionation of 5 fractions per week, 1,8Gy per fraction up to 45-50Gy. Results: So far there is not any local recurrence, but medium follow up is only 18 months. We did not observe any acute damage and the cosmetic outcome was 60% excellent, 30% good and 10% acceptable. Two patients developed localized fibrosis, in both the implant involved the submamary fold. Conclusion: The intraoperative implant is the most accurate way to localize the lumpectomy site, to define the target volume, decrease the total treatment time and avoid a second anesthetic procedure without delaying the inpatient time or the initial wound healing process

  5. [Intraoperative choledochoscopy usefulness in the treatment of difficult biliary stones].

    Science.gov (United States)

    Cuendis-Velázquez, A; Rojano-Rodríguez, M E; Morales-Chávez, C E; González Angulo-Rocha, A; Fernández-Castro, E; Aguirre-Olmedo, I; Torres-Ruiz, M F; Orellana-Parra, J C; Cárdenas-Lailson, L E

    2014-01-01

    Choledocholithiasis presents in 5-10% of the patients with biliary lithiasis. Numerous treatment algorithms have been considered for this disease, however, up to 10% of these therapeutic procedures may fail. Intraoperative choledochoscopy has become a useful tool in the treatment of patients with difficult-to-manage choledocholithiasis. To determine the usefulness of intraoperative choledochoscopy in the laparoendoscopic treatment of difficult stones that was carried out in our service. A cross-sectional study was conducted. The case records were reviewed of the patients that underwent intraoperative choledochoscopy during biliary tree exploration plus laparoscopic choledochoduodenal anastomosis within the time frame of March 1, 2011 and May 31, 2012, at the Hospital General Dr. Manuel Gea González. Transabdominal choledochoscopies were performed with active stone extraction when necessary, followed by peroral choledochoscopies through the recently formed bilioenteric anastomosis. The data were analyzed with descriptive statistics and measures of central tendency. The mean age was 71 years, 57% of the patients were women, and the ASA III score predominated. Active extraction of stones with 7 to 35mm diameters was carried out in 4 of the cases and the absence of stones in the biliary tract was corroborated in all the patients. The mean surgery duration was 18 minutes (range: 4 to 45min). Choledochoscopy is a safe and effective minimally invasive procedure for the definitive treatment of difficult stones. Copyright © 2013 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  6. Pediatric awake craniotomy and intra-operative stimulation mapping.

    Science.gov (United States)

    Balogun, James A; Khan, Osaama H; Taylor, Michael; Dirks, Peter; Der, Tara; Carter Snead Iii, O; Weiss, Shelly; Ochi, Ayako; Drake, James; Rutka, James T

    2014-11-01

    The indications for operating on lesions in or near areas of cortical eloquence balance the benefit of resection with the risk of permanent neurological deficit. In adults, awake craniotomy has become a versatile tool in tumor, epilepsy and functional neurosurgery, permitting intra-operative stimulation mapping particularly for language, sensory and motor cortical pathways. This allows for maximal tumor resection with considerable reduction in the risk of post-operative speech and motor deficits. We report our experience of awake craniotomy and cortical stimulation for epilepsy and supratentorial tumors located in and around eloquent areas in a pediatric population (n=10, five females). The presenting symptom was mainly seizures and all children had normal neurological examinations. Neuroimaging showed lesions in the left opercular (n=4) and precentral or peri-sylvian regions (n=6). Three right-sided and seven left-sided awake craniotomies were performed. Two patients had a history of prior craniotomy. All patients had intra-operative mapping for either speech or motor or both using cortical stimulation. The surgical goal for tumor patients was gross total resection, while for all epilepsy procedures, focal cortical resections were completed without any difficulty. None of the patients had permanent post-operative neurologic deficits. The patient with an epileptic focus over the speech area in the left frontal lobe had a mild word finding difficulty post-operatively but this improved progressively. Follow-up ranged from 6 to 27 months. Pediatric awake craniotomy with intra-operative mapping is a precise, safe and reliable method allowing for resection of lesions in eloquent areas. Further validations on larger number of patients will be needed to verify the utility of this technique in the pediatric population. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Alpha antagonists and intraoperative floppy iris syndrome: A spectrum

    Directory of Open Access Journals (Sweden)

    Sharif A Issa

    2008-07-01

    Full Text Available Sharif A Issa, Omar H Hadid, Oliver Baylis, Margaret DayanDepartment of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UKBackground: To determine occurrence of features of intraoperative floppy iris syndrome (IFIS during cataract surgery in patients taking systemic alpha-antagonists (AA.Methods: We prospectively studied patients on AA and who underwent phacoemulsification. The following were recorded: pupil diameter preoperatively, iris flaccidity, iris prolapse and peroperative miosis.Results: We studied 40 eyes of 31 subjects. Mean age was 78 years. Overall, 14 eyes (13 patients showed signs of IFIS: 9/13 (69% eyes of patients on tamsulosin, 1/18 (6% eyes in the doxazosin group, 2/2 prazosin patients, 1/4 eyes in the indoramin group, and 1/2 eyes in two patients on a combination of doxazosin and tamsulosin. Most cases (92% had only one or two signs of IFIS. Bilateral cataract surgery was undertaken in 9 patients but only one patient (on tamsulosin had features of IFIS in both eyes, while 4 patients (2 on tamsulosin and 2 on other AA showed signs of IFIS in one eye only, and 4 patients did not show IFIS in either eye.Conclusion: Most AA were associated with IFIS, but it tends to present as a spectrum of signs rather than full triad originally described. Tamsulosin was most likely to be associated with IFIS; however, its intake does not necessarily mean that IFIS will occur. For patients on AA, the behavior of the iris intraoperatively in one eye is a poor predictor of the other eye. Surgeons should anticipate the occurrence of IFIS in any patient on AA.Keywords: alpha blocker, alpha antagonist, cataract surgery, intraoperative floppy iris syndrome, tamsulosin.

  8. Microdebrider tonsillectomy associated with more intraoperative blood loss than electrocautery.

    Science.gov (United States)

    Stansifer, Kyle J; Szramowski, Molly G; Barazsu, Lindsay; Buchinsky, Farrel J

    2012-10-01

    To describe and compare the intraoperative blood loss in children who underwent tonsillectomy and/or adenoidectomy during a transition from using electrocautery to a microdebrider. Retrospective case series of a single pediatric otolaryngologist at an urban general hospital. Patients aged 2-20 years who had tonsillectomy, adenoidectomy, or adenotonsillectomy over a 12 month period were included. Tonsillectomy was performed by microdebrider or electrocautery and adenoidectomy was performed by microdebrider, curette, or suction electrocautery. Total intraoperative blood loss was measured and compared between surgical techniques. Of the 148 patients, 109 had tonsillectomy with or without adenoidectomy and 39 had adenoidectomy alone. The mean blood loss was 47 ml or 1.8 ± 1.6 ml/kg and the maximum blood loss was 11 ml/kg. Adenoid curette and adenoid microdebrider yielded similar blood loss but were associated with more bleeding than suction electrocautery (Pelectrocautery tonsillectomy (mean of 2.6 ± 2.2 ml/kg versus 1.2 ± 1.2 ml/kg, P=0.0002). Eighteen percent of adenotonsillectomy patients lost greater than 5% of calculated circulating blood volume (95% CI, 9.8-26). Linear regression models did not show an association between the amount of blood loss and patient age, clinical indication, or the surgeon's experience with the microdebrider (P>0.05). Microdebrider tonsillectomy is associated with more intraoperative bleeding than electrocautery tonsillectomy. Approximately twice as much blood was lost with the microdebrider, but the absolute increase was insignificant from a hemodynamic perspective. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Intraoperative neurophysiology of the conus medullaris and cauda equina.

    Science.gov (United States)

    Kothbauer, Karl F; Deletis, Vedran

    2010-02-01

    Intraoperative neurophysiological techniques are becoming routine tools for neurosurgical practice. Procedures affecting the lumbosacral nervous system are frequent in adult and pediatric neurosurgery. This review provides an overview of the techniques utilized in cauda and conus operations. Two basic methodologies of intraoperative neurophysiological testing are utilized during surgery in the lumbosacral spinal canal. Mapping techniques help identify functional neural structures, namely, nerve roots and their respective spinal levels. Monitoring is referred to as the technology to continuously assess the functional integrity of pathways and reflex circuits. For mapping direct electrical stimulation of a structure within the surgical field and recording at a distant site, usually a muscle is the most commonly used setup. Sensory nerve roots or spinal cord areas can be mapped by stimulation of a distant sensory nerve or skin area and recording from a structure within the surgical field. Continuous monitoring of the motor system is done with motor evoked potentials. These are evoked by transcranial electrical stimulation and recorded from lower extremity and sphincter muscles. Presence or absence of muscle responses are the monitored parameters. To monitor the sensory pathways, sensory potentials evoked by tibial, peroneal, or pudendal nerve stimulation and recorded from the dorsal columns with a spinal electrode or as cortical responses from scalp electrodes are used. Amplitudes and latencies of these responses are measured for interpretation. The bulbocavernosus reflex, with stimulation of the pudendal nerve and recording from the external anal sphincter, is used for continuous monitoring of the reflex circuitry. The presence of absence of this response is the pertinent parameter monitored. Stimulation of individual dorsal nerve roots is used to identify those segments that generate spastic activity and which may be cut during selective dorsal rhizotomy

  10. Selling the green dream

    International Nuclear Information System (INIS)

    Wood, E.

    2005-01-01

    The article discusses the marketing and sales of energy generated from renewable energy sources. To purchase environmental energy in the USA, the consumer need do no more than tick a box on a sheet of paper. But, it is not just households that opt for green energy: businesses are also willing customers. A factor in the success in selling green energy to big business is that the retail price of wind power can be held constant over periods of several years, whereas fossil fuel prices can fluctuate wildly. Details of sources and sales of the top ten companies selling green energy are given

  11. Manufacturing Green Consensus

    DEFF Research Database (Denmark)

    Gulsrud, Natalie Marie; Ooi, Can Seng

    2014-01-01

    In an increasingly global economy, being green, or having an environmentally sustainbale place brand, provides a competitive advantage. Singapore, long known as the ``garden city´´ has been a leader in green city imaging since the founding of the equatorial city-state, contributing, in large part...... to the city’s profile as the economic giant of Southeast Asia. Using a political ecology lens, the paper aims to uncover the contested socio-economic narratives of green city imaging by examining the evolution of the garden city branding scheme since Singapore’s independence in 1959. Results show...

  12. About green political parties

    Directory of Open Access Journals (Sweden)

    Orlović Slobodan P.

    2015-01-01

    Full Text Available In this work the author refers to some legal and political questions in connection with green political parties. Those questions cover: the ideology of green political parties, their number and influence, both in general and in Serbia. The first part of work is generally speaking about political parties - their definition, ideology, role and action. Main thesis in this work is that green political parties, by their appearance, were something new on the political scene. But quickly, because of objective and subjective reasons, they were changing original ideas and were beginning to resemble to all other political parties. In this way, they lost their vanguard and political alternativeness.

  13. Prevention of intraoperative cerebrospinal fluid leaks by lumbar cerebrospinal fluid drainage during surgery for pituitary macroadenomas.

    Science.gov (United States)

    Mehta, Gautam U; Oldfield, Edward H

    2012-06-01

    Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p drainage reduced the need for operative repair (from 32% to 5%, p drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.

  14. Intraoperative computed tomography with integrated navigation system in spinal stabilizations.

    Science.gov (United States)

    Zausinger, Stefan; Scheder, Ben; Uhl, Eberhard; Heigl, Thomas; Morhard, Dominik; Tonn, Joerg-Christian

    2009-12-15

    STUDY DESIGN.: A prospective interventional case-series study plus a retrospective analysis of historical patients for comparison of data. OBJECTIVE.: To evaluate workflow, feasibility, and clinical outcome of navigated stabilization procedures with data acquisition by intraoperative computed tomography. SUMMARY OF BACKGROUND DATA.: Routine fluoroscopy to assess pedicle screw placement is not consistently reliable. Our hypothesis was that image-guided spinal navigation using an intraoperative CT-scanner can improve the safety and precision of spinal stabilization surgery. METHODS.: CT data of 94 patients (thoracolumbar [n = 66], C1/2 [n = 12], cervicothoracic instability [n = 16]) were acquired after positioning the patient in the final surgical position. A sliding gantry 40-slice CT was used for image acquisition. Data were imported to a frameless infrared-based neuronavigation workstation. Intraoperative CT was obtained to assess the accuracy of instrumentation and, if necessary, the extent of decompression. All patients were clinically evaluated by Odom-criteria after surgery and after 3 months. RESULTS.: Computed accuracy of the navigation system reached /=2 mm without persistent neurologic or vascular damage in 20/414 screws (4.8%) leading to immediate correction of 10 screws (2.4%). Control-iCT changed the course of surgery in 8 cases (8.5% of all patients). The overall revision rate was 8.5% (4 wound revisions, 2 CSF fistulas, and 2 epidural hematomas). There was no reoperation due to implant malposition. According to Odom-criteria all patients experienced a clinical improvement. A retrospective analysis of 182 patients with navigated thoracolumbar transpedicular stabilizations in the preiCT era revealed an overall revision rate of 10.4% with 4.4% of patients requiring screw revision. CONCLUSION.: Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization

  15. Visualization strategies for major white matter tracts for intraoperative use

    Energy Technology Data Exchange (ETDEWEB)

    Nimsky, C.; Ganslandt, O.; Buchfelder, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Neurosurgery; Erlangen-Nuernberg Univ., Erlangen (Germany). Neurocenter; Enders, F.; Merhof, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Neurocenter; Hammen, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Neurocenter; Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Neurology

    2006-03-15

    Streamline representation of major fiber tract systems along with high-resolution anatomical data provides a reliable orientation for the neurosurgeon. For intraoperative visualization of these data either on navigation screens near the surgical field or directly in the surgical field applying heads-up displays of operating microscopes, wrapping of all streamlines of interest to render an individual object representing the whole fiber bundle is the most suitable representation. Integration of fiber tract data into a neuronavigation setup allows removal of tumors adjacent to eloquent brain areas with low morbidity. (orig.)

  16. Visualization strategies for major white matter tracts for intraoperative use

    International Nuclear Information System (INIS)

    Nimsky, C.; Ganslandt, O.; Buchfelder, M.; Erlangen-Nuernberg Univ., Erlangen; Enders, F.; Merhof, D.; Hammen, T.; Erlangen-Nuernberg Univ., Erlangen

    2006-01-01

    Streamline representation of major fiber tract systems along with high-resolution anatomical data provides a reliable orientation for the neurosurgeon. For intraoperative visualization of these data either on navigation screens near the surgical field or directly in the surgical field applying heads-up displays of operating microscopes, wrapping of all streamlines of interest to render an individual object representing the whole fiber bundle is the most suitable representation. Integration of fiber tract data into a neuronavigation setup allows removal of tumors adjacent to eloquent brain areas with low morbidity. (orig.)

  17. Non-radiographic intraoperative fluorescent cholangiography is feasible

    DEFF Research Database (Denmark)

    Larsen, Søren Schytt; Schulze, Svend; Bisgaard, Thue

    2014-01-01

    INTRODUCTION: Intraoperative fluorescent cholangiography (IFC) with concomitant fluorescent angiography was recently developed for non-invasive identification of the anatomy during laparoscopic cholecystectomy. The objective of this study was to assess the time required for routine-use of IFC...... hepatic duct was identified by IFC in all patients. In 29 of the 35 patients (83%; 95% confidence interval: 71-96%), the cystic artery was visualised by fluorescent angiography. No adverse effects or complications were recorded. CONCLUSION: Routine-use of IFC with fluorescent angiography during...

  18. A CASE OF GRANISETRON ASSOCIATED INTRAOPERATIVE CARDIAC ARREST.

    Science.gov (United States)

    Al Harbi, Mohammed; Al Rifai, Derar; Al Habeeb, Hassan; Wambi, Freddie; Geldhof, Georges; Dimitriou, Vassilios

    2016-02-01

    We report a case of intraoperative severe bradycardia that resulted in asystole and cardiac arrest shortly after (granisetron 1mg for postoperative nausea and vomiting prophylaxis, that occurred in a female patient who underwent an elective total thyroidectomy. After two cycles of cardiopulmonary resuscitation and defibrillation, spontaneous circulation and sinus rhythm returned successfully. Postoperatively, the patient was diagnosed with a drug-induced long QT syndrome. At the time of the event, granisetron was the only medication administered. Furthermore, there was no reason to suspect electrolyte abnormalities. We explore the association of the onset of severe sinus bradycardia with the intravenous administration of granisetron.

  19. Intraoperative radiotherapy of malignant pancreatic tumors - first results

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, S.; Glaser, K.; Url, M.; Frommhold, H.; Bodner, E.

    1987-02-01

    Thirteen patients suffering from adenocarcinomas of the pancreas were submitted to an intraoperative fast electron 'boost' therapy with or without percutaneous photon irradiation. A duodeno-cephalo-pancreatectomy with subsequent irradiation of the tumor bed could be performed in three patients. Ten patients were inoperable because of advanced tumors and formation of metastases. The average survival is 6.5 months, at present six patients are alive without major troubles. An analgetic effect was obtained in ten patients. The first results are encouraging with respect to local control, the little acute and chronic morbidity, and palliation achieved in advances stages.

  20. Intraoperative radiotherapy of malignant pancreatic tumors - first results

    International Nuclear Information System (INIS)

    Thurnher, S.; Glaser, K.; Url, M.; Frommhold, H.; Bodner, E.; Innsbruck Univ.

    1987-01-01

    Thirteen patients suffering from adenocarcinomas of the pancreas were submitted to an intraoperative fast electron 'boost' therapy with or without percutaneous photon irradiation. A duodeno-cephalo-pancreatectomy with subsequent irradiation of the tumor bed could be performed in three patients. Ten patients were inoperable because of advanced tumors and formation of metastases. The average survival is 6.5 months, at present six patients are alive without major troubles. An analgetic effect was obtained in ten patients. The first results are encouraging with respect to local control, the little acute and chronic morbidity, and palliation achieved in advances stages. (orig.) [de

  1. Intraoperative neuropathology of glioma recurrence: cell detection and classification

    Science.gov (United States)

    Abas, Fazly S.; Gokozan, Hamza N.; Goksel, Behiye; Otero, Jose J.; Gurcan, Metin N.

    2016-03-01

    Intraoperative neuropathology of glioma recurrence represents significant visual challenges to pathologists as they carry significant clinical implications. For example, rendering a diagnosis of recurrent glioma can help the surgeon decide to perform more aggressive resection if surgically appropriate. In addition, the success of recent clinical trials for intraoperative administration of therapies, such as inoculation with oncolytic viruses, may suggest that refinement of the intraoperative diagnosis during neurosurgery is an emerging need for pathologists. Typically, these diagnoses require rapid/STAT processing lasting only 20-30 minutes after receipt from neurosurgery. In this relatively short time frame, only dyes, such as hematoxylin and eosin (H and E), can be implemented. The visual challenge lies in the fact that these patients have undergone chemotherapy and radiation, both of which induce cytological atypia in astrocytes, and pathologists are unable to implement helpful biomarkers in their diagnoses. Therefore, there is a need to help pathologists differentiate between astrocytes that are cytologically atypical due to treatment versus infiltrating, recurrent, neoplastic astrocytes. This study focuses on classification of neoplastic versus non-neoplastic astrocytes with the long term goal of providing a better neuropathological computer-aided consultation via classification of cells into reactive gliosis versus recurrent glioma. We present a method to detect cells in H and E stained digitized slides of intraoperative cytologic preparations. The method uses a combination of the `value' component of the HSV color space and `b*' component of the CIE L*a*b* color space to create an enhanced image that suppresses the background while revealing cells on an image. A composite image is formed based on the morphological closing of the hue-luminance combined image. Geometrical and textural features extracted from Discrete Wavelet Frames and combined to classify

  2. Clinical experience with intraoperative radiotherapy for locally advanced colorectal cancer

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Takahashi, Masaharu; Abe, Mitsuyuki

    1988-01-01

    Intraoperative radiotherapy (IORT) was performed on 20 patients with colorectal cancer. IORT with a single dose of 20 to 40 Gy was delivered to the residual tumor, tumor bed, and/or lymphnode regions. Although most of the patients had advanced lesions, local control was achieved in 67 % of the patients when IORT was combined with tumor resection, and 4 patients survived more than 5 years. There were no serious complications, except for contracture or atrophy of the psoas muscle seen in 2 patients. IORT combined with external beam radiotherapy should be a useful adjuvant therapy to surgery for locally advanced colorectal cancer. (author)

  3. Intraoperative Anaphylaxis to Inj Ceftriaxone: Here We Go Again

    Directory of Open Access Journals (Sweden)

    Amit G Bhagwat

    2008-01-01

    Full Text Available Anaphylactic reactions to intraoperative antibiotics are rare events and reactions after a negative intradermal skin testing are even rarer. We are reporting a case of grade V anaphylactic reaction to ceftriaxone, which occurred inspite of a negative skin testing preoperatively. Despite of the treatment along the established guidelines, patient suffered hypoxic brain damage ultimately having a fatal outcome 7 days later. This case highlights the limits of the screening test done preoperatively for antibiotic sensitivity and also the difficulty in resuscitating anaphylactic reac-tions when patient is on B blocker and under spinal anaesthesia.

  4. Sustainable green urban planning: the Green Credit Tool

    NARCIS (Netherlands)

    Cilliers, E.J.; Diemont, E.; Stobbelaar, D.J.; Timmermans, W.

    2010-01-01

    Purpose – The Green Credit Tool is evaluated as a method to quantify the value of green-spaces and to determine how these green-space-values can be replaced or compensated for within urban spatial planning projects. Design/methodology/approach – Amersfoort Local Municipality created the Green Credit

  5. Green Supplier Selection Criteria

    DEFF Research Database (Denmark)

    Nielsen, Izabela Ewa; Banaeian, Narges; Golinska, Paulina

    2014-01-01

    Green supplier selection (GSS) criteria arise from an organization inclination to respond to any existing trends in environmental issues related to business management and processes, so GSS is integrating environmental thinking into conventional supplier selection. This research is designed...... to determine prevalent general and environmental supplier selection criteria and develop a framework which can help decision makers to determine and prioritize suitable green supplier selection criteria (general and environmental). In this research we considered several parameters (evaluation objectives......) to establish suitable criteria for GSS such as their production type, requirements, policy and objectives instead of applying common criteria. At first a comprehensive and deep review on prevalent and green supplier selection literatures performed. Then several evaluation objectives defined to assess the green...

  6. Green Building Standards

    Science.gov (United States)

    Many organizations have developed model codes or rating systems that communities may use to develop green building programs or revise building ordinances. Some of the major options are listed on this page.

  7. Introduction: Green Building Handbook

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-08-01

    Full Text Available By recognising the specific environmental challenges facing South Africa, mindful of the government‘s commitment to reducing South Africa‘s Greenhouse gas emissions, and acknowledging the need to build social cohesion, the Green Building Handbook...

  8. Green certificates causing inconvenience?

    International Nuclear Information System (INIS)

    Torgersen, Lasse

    2002-01-01

    From early 2002, producers of green energy in selected countries have been able to benefit from generous financial support in the Netherlands. Thus, there has been increased sale of green certificates from Norway and Sweden. But the condition that physical energy delivery should accompany the certificates has caused a marked rise in the price of energy in transit through Germany to the Netherlands. This article discusses the green certificate concept and the experience gained from the Netherlands. One conclusion is that if large-scale trade with green certificates is introduced in Europe without the condition of accompanying energy delivery, then producers of hydro-electric power in Norway and Sweden may be the losers

  9. Green space as classroom

    DEFF Research Database (Denmark)

    Bentsen, Peter; Schipperijn, Jasper; Jensen, Frank Søndergaard

    2013-01-01

    More and more Danish teachers have started introducing curriculum-based outdoor learning as a weekly or biweekly ‘outdoor school’ day for school children. This move towards schooling in non-classroom spaces presents a challenge for green space managers. Basic managerial knowledge related to what......, who, when and where has thus far only been supported by anecdotal evidence, but seems fundamental to the decision-making of a range of green space providers. The present study aims to describe, characterise and discuss outdoor teachers’ use, preferences and ecostrategies in relation to green space....... A nationwide survey was conducted among Danish teachers practising outdoor teaching (107 respondents), and it showed that a majority used and preferred forest areas. The outdoor teachers used mainly school grounds and local green space for their outdoor teaching with a majority using the same place or mostly...

  10. Green by Default

    DEFF Research Database (Denmark)

    Sunstein, Cass R.; Reisch, Lucia

    2013-01-01

    The article offers information on the two sources of energy including green energy and gray energy. It discusses several facts which includes lower levels of greenhouse gases and conventional pollutants, relationship between economic incentives and underlying preferences and potential effects...

  11. Green Sturgeon Acoustic Monitoring

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database is used to hold tracking data for green sturgeon tagged in Central California. The data collection began in late 2002 and is ongoing.

  12. Green Turtle Critical Habitat

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data represent the critical habitat for green turtle as designated by Federal Register Vol. 63, No. 46701, September 2, 1998, Rules and Regulations.

  13. Green Turtle Trophic Ecology

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — SWFSC is currently conducting a study of green sea turtle (Chelonia mydas) trophic ecology in the eastern Pacific. Tissue samples and stable carbon and stable...

  14. Decon Green (trademark)

    National Research Council Canada - National Science Library

    Wagner, George W; Procell, Lawrence R; Henderson, Vikki D; Sorrick, David C; Hess, Zoe A; Gehring, David G; Brickhouse, Mark D

    2004-01-01

    ...; it affords the broad-spectrum decontamination of chemical and biological warfare agents. Composed entirely of ingredients commonly found in cosmetics, detergents, laundry boosters, and vitamins, Decon Green (trademark...

  15. Superfund Green Remediation

    Science.gov (United States)

    Green remediation is the practice of considering all environmental effects of site cleanup and incorporating options – like the use of renewable energy resources – to maximize the environmental benefits of cleanups.

  16. ADVANTAGES OF GREEN TECHNOLOGY

    OpenAIRE

    Ghanshyam Das Soni

    2017-01-01

    Technology is application of knowledge to practical requirements. Green technologies encompass various aspects of technology which help us reduce the human impact on the environment and create ways of sustainable development. Social equitability, economic feasibility and sustainability are the key parameters for green technologies. Today the environment is racing towards the tipping point at which we would have done permanent irreversible damage to the planet earth. Our current actions are pu...

  17. What is a green building?

    NARCIS (Netherlands)

    Vreenegoor, R.C.P.; Krikke, T.; Mierlo, van B.P.; Pluijm, van der W.M.P.; Poortvliet, R.; Hensen, J.L.M.; Loomans, M.G.L.C.

    2009-01-01

    What is a green building? A large amount of definitions and green rating tools prove that an exact definition is still a point of discussion. To research the differences between green rating tools, four different buildings are assessed with: EPN, BREEAM, LEED, GreenCalc+ and EcoQuantum. These tools

  18. Improvement of limb salvage procedure using intraoperative radiotherapy for osteosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Toru; Iwasaki, Katsuo; Kamishiro,; Toshiyuki,; Hayashi, Yasuyuki [Nagasaki Univ. (Japan). School of Medicine

    1992-10-01

    Clinical outcome of limb salvage procedure combined with intraoperative irradiation was investigated in 6 patients with osteosarcoma in the distal part of femur (n=4) and proximal part of tibia (n=2). They ranged in age from 12 to 54 years, with a mean of 22.5. First, a lesion was separated from the surrounding soft tissue with curatively wide margin. Osteotomy was performed at the portion of diaphysis. After irradiation field was setted up by lifting the lesion, and was exposed to doses ranging from 60 Gy to 85 Gy of intraoperative irradiation, soft tissue and fragile tumor tissue, excluding joint capsule and ligament, were removed as soon as possible. Finally, bone was jointed by means of inner fixation or bone grafting. They had a median follow-up of one year and four months after surgery. Although superficial wound infection and delayed wound adhesion were encountered as postoperative complications in one and two patients, respectively, these were all healed. None of the patients had local recurrence. The ability of salvaged limb was excellent in one, good in 3, and fair in 2 patients. Because both of the two patients with sarcoma in the proximal part of tibia had excellent and good limb ability, this procedure was considered useful especially for sarcoma in the proximal part of tibia. (N.K.).

  19. Integrating multimodal information for intraoperative assistance in neurosurgery

    Directory of Open Access Journals (Sweden)

    Eisenmann U.

    2015-09-01

    Full Text Available Computer-assisted planning of complex neurosurgical interventions benefits from a variety of specific functions and tools. However, commercial planning- and neuronavigation systems are rather restrictive concerning the availability of innovative methods such as novel imaging modalities, fiber tracking algorithms or electrical dipole mapping. In this respect there is a demand for modular neurosurgical planning systems offering flexible interfaces for easy enhancement. Furthermore all relevant planning information should be available within neuron-avigation. In this work we present a planning system providing these capabilities and its suitability and application in a clinical setting. Our Multimodal Planning System (MOPS 3D offers a variety of tools such as definition of trajectories for minimally invasive surgery, segmentation of ROIs, integration of functional information from atlas maps or magnetoencephalography. It also supplies plugin interfaces for future extensions. For intraoperative application MOPS is coupled with the neuronavigation system Brainlab Vector Vision Cranial/ENT (VVC. We evaluated MOPS in the Department of Neurosurgery at the University Hospital Heidelberg. Surgical planning and navigation was performed in 5 frequently occurring clinical cases. The time necessary for planning was between 5 and 15 minutes including data import, segmentation and planning tasks. The additional information intraoperatively provided by MOPS 3D was highly appreciated by the neurosurgeons and the performance was satisfactory.

  20. A case of lumbar pain after intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Wakako; Ogino, Takashi; Murakami, Koji; Nawano, Shigeru; Moriyama, Noriyuki; Ryu, Munemasa; Kawano, Nariaki

    1996-01-01

    We report a case of abnormal magnetic resonance imaging (MRI) findings after intraoperative radiotherapy. A 53-year-old woman with cancer of the papilla of Vater was treated with pancreatoduodenectomy and 20 Gy of intraoperative radiotherapy by electron beam to the tumor bed. Three months later the patient complained of lumbar pain. A change of signal intensity on MRI was detected in the anterior half of the vertebral body within the irradiated field. The signal was of high intensity but was not enhanced by Gd-DTPA on T1-weighted images, was isointense on T2-weighted images and of low intensity with the fat-suppression method. The radiation dose to the lumbar spine and the surrounding soft tissue was calculated to be 16 Gy. Histologic changes in bone after irradiation may include depletion of bone marrow cells and fat degeneration. The MRI findings were compatible with these changes. The radiation dose that can be tolerated by soft tissue is lower than that tolerated by bone. Therefore, late radiation injury of the soft tissue might have been the cause of the patient's lumbar pain. (author)

  1. Improvement of limb salvage procedure using intraoperative radiotherapy for osteosarcoma

    International Nuclear Information System (INIS)

    Hirano, Toru; Iwasaki, Katsuo; Kamishiro; Toshiyuki; Hayashi, Yasuyuki

    1992-01-01

    Clinical outcome of limb salvage procedure combined with intraoperative irradiation was investigated in 6 patients with osteosarcoma in the distal part of femur (n=4) and proximal part of tibia (n=2). They ranged in age from 12 to 54 years, with a mean of 22.5. First, a lesion was separated from the surrounding soft tissue with curatively wide margin. Osteotomy was performed at the portion of diaphysis. After irradiation field was setted up by lifting the lesion, and was exposed to doses ranging from 60 Gy to 85 Gy of intraoperative irradiation, soft tissue and fragile tumor tissue, excluding joint capsule and ligament, were removed as soon as possible. Finally, bone was jointed by means of inner fixation or bone grafting. They had a median follow-up of one year and four months after surgery. Although superficial wound infection and delayed wound adhesion were encountered as postoperative complications in one and two patients, respectively, these were all healed. None of the patients had local recurrence. The ability of salvaged limb was excellent in one, good in 3, and fair in 2 patients. Because both of the two patients with sarcoma in the proximal part of tibia had excellent and good limb ability, this procedure was considered useful especially for sarcoma in the proximal part of tibia. (N.K.)

  2. Tumors in dogs exposed to experimental intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Johnstone, Peter A.S.; Laskin, William B.; De Luca, Anne Marie; Barnes, Margaret; Kinsella, Timothy J.; Sindelar, William F.

    1996-01-01

    Purpose: The frequency of radiation-induced neoplasms was determined in dogs enrolled in the National Cancer Institute canine trials of intraoperative radiotherapy (IORT). Methods and Materials: Twelve protocols assessing normal tissue response to IORT involved 238 dogs in a 15-year trial. Eighty-one dogs were followed for > 24 months postoperatively and were assessed for tumor development; 59 of these animals received IORT. Results: Twelve tumors occurred in the 59 dogs receiving IORT. Nine were in the IORT portals and were considered to be radiation induced. No tumors occurred in 13 sham animals or in 9 animals treated with external beam radiotherapy alone. The frequency of radiation-induced malignancies in dogs receiving IORT was 15%, and was 25% in animals receiving ≥ 25 Gy IORT. Frequency of all tumors, including spontaneous lesions, was 20%. Conclusions: Intraoperative radiotherapy contributed to a high frequency of sarcoma induction in these dogs. Unknown to date in humans involved in clinical trials of IORT, this potential complication should be looked for as long-term survivors are followed

  3. Neurophysiological intraoperative monitoring during an optic nerve schwannoma removal.

    Science.gov (United States)

    San-Juan, Daniel; Escanio Cortés, Manuel; Tena-Suck, Martha; Orozco Garduño, Adolfo Josué; López Pizano, Jesús Alejandro; Villanueva Domínguez, Jonathan; Fernández Gónzalez-Aragón, Maricarmen; Gómez-Amador, Juan Luis

    2017-10-01

    This paper reports the case of a patient with optic nerve schwannoma and the first use of neurophysiological intraoperative monitoring of visual evoked potentials during the removal of such tumor with no postoperative visual damage. Schwannomas are benign neoplasms of the peripheral nervous system arising from the neural crest-derived Schwann cells, these tumors are rarely located in the optic nerve and the treatment consists on surgical removal leading to high risk of damage to the visual pathway. Case report of a thirty-year-old woman with an optic nerve schwannoma. The patient underwent surgery for tumor removal on the left optic nerve through a left orbitozygomatic approach with intraoperative monitoring of left II and III cranial nerves. We used Nicolet Endeavour CR IOM (Carefusion, Middleton WI, USA) to performed visual evoked potentials stimulating binocularly with LED flash goggles with the patient´s eyes closed and direct epidural optic nerve stimulation delivering rostral to the tumor a rectangular current pulse. At follow up examinations 7 months later, the left eye visual acuity was 20/60; Ishihara score was 8/8 in both eyes; the right eye photomotor reflex was normal and left eye was mydriatic and arreflectic; optokinetic reflex and ocular conjugate movements were normal. In this case, the epidural direct electrical stimulation of optic nerve provided stable waveforms during optic nerve schwannoma resection without visual loss.

  4. Compact Intraoperative MRI: Stereotactic Accuracy and Future Directions.

    Science.gov (United States)

    Markowitz, Daniel; Lin, Dishen; Salas, Sussan; Kohn, Nina; Schulder, Michael

    2017-01-01

    Intraoperative imaging must supply data that can be used for accurate stereotactic navigation. This information should be at least as accurate as that acquired from diagnostic imagers. The aim of this study was to compare the stereotactic accuracy of an updated compact intraoperative MRI (iMRI) device based on a 0.15-T magnet to standard surgical navigation on a 1.5-T diagnostic scan MRI and to navigation with an earlier model of the same system. The accuracy of each system was assessed using a water-filled phantom model of the brain. Data collected with the new system were compared to those obtained in a previous study assessing the older system. The accuracy of the new iMRI was measured against standard surgical navigation on a 1.5-T MRI using T1-weighted (W) images. The mean error with the iMRI using T1W images was lower than that based on images from the 1.5-T scan (1.24 vs. 2.43 mm). T2W images from the newer iMRI yielded a lower navigation error than those acquired with the prior model (1.28 vs. 3.15 mm). Improvements in magnet design can yield progressive increases in accuracy, validating the concept of compact, low-field iMRI. Avoiding the need for registration between image and surgical space increases navigation accuracy. © 2017 S. Karger AG, Basel.

  5. The use of near-infrared fluorescence imaging in endocrine surgical procedures.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-06-01

    Near-infrared fluorescence imaging in endocrine surgery is a new, yet highly investigated area. It involves indocyanine green use as well as parathyroid autofluorescence. Several groups have described their technique and reported on the observed utility. However, there is no consensus on technical details. Furthermore, the correlation between intraoperative findings and postoperative outcomes is unclear. With this study, we aim to review the current literature on fluorescence imaging and share our insights on technical details. © 2017 Wiley Periodicals, Inc.

  6. The Influence of Proactive Green Innovation and Reactive Green Innovation on Green Product Development Performance: The Mediation Role of Green Creativity

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2016-09-01

    Full Text Available This study fills the research gap in the exploration of the relationships between both proactive and reactive green innovations and green product development performance, and examines the mediating effect of green creativity. Structural equation modeling (SEM is utilized to test the hypotheses. From the sample of 146 valid respondents, the results show that proactive green innovation positively affects green creativity and green product development performance, and green creativity positively affects green product development performance. In addition, our findings also indicate that the relationship between proactive green innovation and green product development performance is partially mediated by green creativity. Accordingly, green creativity plays a critical role for companies to achieve a great green product development performance. However, reactive green innovation does not significantly influence green creativity and green product development performance. Companies should develop proactive green innovation rather than reactive green innovation in order to enhance their green creativity and increase their product development performance.

  7. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  8. The Influence of Environmental Friendliness on Green Trust: The Mediation Effects of Green Satisfaction and Green Perceived Quality

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2015-07-01

    Full Text Available As global green trends became more prevalent, green marketing also developed into an important issue. Although prior literature explored the main factors affecting green trust, it was inconclusive as to how environmental friendliness could affect the green trust in green marketing. This study aims to focus on the positive influence of environmental friendliness on green trust, and explore the mediation effects of green satisfaction and green perceived quality. This study undertakes an empirical study by means of questionnaire survey. The respondents are consumers who have experience purchasing green products. This study applies structural equation modeling (SEM to test the hypotheses. The findings of this study indicate that (1 environmental friendliness has a significant positive impact on green satisfaction, green perceived quality, and green trust; (2 both green satisfaction and green perceived quality positively affect green trust; and (3 green satisfaction and green perceived quality partially mediate the positive relationship between environmental friendliness and green trust.

  9. Intra-operative blood transfusion among adult surgical patients in a ...

    African Journals Online (AJOL)

    This retrospective study was designed to audit the pattern of intra-operative whole blood transfusion among adult surgical patients over a two-year period. Data were collected on the rate of intra-operative transfusion, estimated blood loss, units of donor blood transfused, pattern of use of autologous blood and circumstances ...

  10. Is Intraoperative Diffusion tensor Imaging at 3.0T Comparable to Subcortical Corticospinal tract Mapping?

    Czech Academy of Sciences Publication Activity Database

    Ostrý, S.; Belšan, T.; Otáhal, Jakub; Beneš, V.; Netuka, D.

    2013-01-01

    Roč. 73, č. 5 (2013), s. 797-807 ISSN 0148-396X Institutional support: RVO:67985823 Keywords : corticospinal tract * intraoperative tractography * intraoperative image distortion * motor -evoked potentials * subcortical mapping Subject RIV: FH - Neurology Impact factor: 3.031, year: 2013

  11. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  12. Study on intraoperative radiotherapy applying hyperthermia together with radiation sensitizers for progressive local carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Abe, M; Takahashi, M; Ono, K; Hiraoka, M [Kyoto Univ. (Japan). Faculty of Medicine

    1980-08-01

    Intraoperative radiotherapy for gastric cancer, colonic cancer, pancreatic cancer, cancer of the biliary tract, prostatic carcinoma, cerebral tumor, tumor of soft tissues, and osteosarcoma and its clinical results were described. Basic and clinical studies on effects of both hyperthermia and radiation sensitizers to elevate radiation sensitivity were also described, because effects of intraoperative radiotherapy were raised by applying hyperthermia and hypoxic cell sensitizers.

  13. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint

    OpenAIRE

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct...

  14. Intraoperative hypothermia and its clinical outcomes in patients undergoing general anesthesia: National study in China.

    Directory of Open Access Journals (Sweden)

    Jie Yi

    Full Text Available Inadvertent intraoperative hypothermia (core temperature 2 h (OR = 2.60, 95% CI 2.09-3.24.The incidence of intraoperative hypothermia in China is high, and the rate of active warming of patients during operation is low. Hypothermia is associated with more postoperative shivering, increased ICU admissions, and longer postoperative hospital days.

  15. INTRAOPERATIVE MOTIVE FOR PERFORMING A LAPAROSCOPIC APPENDECTOMY ON A POSTOPERATIVE HISTOLOGICAL PROVEN NORMAL APPENDIX

    NARCIS (Netherlands)

    Slotboom, T.; Hamminga, J. T. H.; Hofker, H. S.; Heineman, E.; Haveman, J. W.

    2014-01-01

    Background: Diagnostic laparoscopy is the ultimate tool to evaluate the appendix. However, the intraoperative evaluation of the appendix is difficult, as the negative appendectomy rate remains 12%-18%. The aim of this study is to analyze the intraoperative motive for performing a laparoscopic

  16. Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification. Observational study.

    Science.gov (United States)

    Vasavada, Viraj; Vasavada, Vaishali; Raj, Shetal M; Vasavada, Abhay R

    2007-06-01

    To evaluate the intraoperative performance and postoperative outcomes after microcoaxial phacoemulsification. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. A prospective observational case series comprised 84 eyes with age-related uncomplicated cataract having microcoaxial phacoemulsification through a 2.2 mm clear corneal incision by a standard surgical technique. Phacoemulsification parameters (Infiniti Vision System, Alcon) were microburst width, 30 ms; preset power, 50%; vacuum, 650 mm Hg; aspiration flow rate, 25 cc/minute. A single-piece Alcon AcrySof intraocular lens was implanted with the C cartridge (Alcon) cartridge. The incision was measured at the end of surgery. Observations included surgical time (from commencement of sculpting to end of epinucleus removal), cumulative dissipated energy (CDE), wound burns, intraoperative complications, postoperative increase in mean central corneal thickness (CCT) at 1 day and 1 month, mean % decrease in endothelial cell density (ECD), absolute mean change in coefficient of variation (cv) 3 months, and uncorrected visual acuity (UCVA) at 1 day. Data were analyzed using a 1-sample t test with 95% confidence intervals (CIs). The mean follow up was 3 months +/- 0.3 (SD). The mean incision size at the end of surgery was 2.3 +/- .09 mm; mean surgical time, 4.5 +/- 1.5 minutes; and mean CDE, 2.3 +/- 2.2 seconds. No wound burns or other intraoperative complications occurred. The postoperative CCT increased by a mean of 16 microm at 1 day (95% CI, 8-25; P = .66;) and by a mean of 3.14 microm at 1 month (95% CI, 2.26-4.05; P = .92). The ECD decreased by a mean of 5.8% (95% CI, 6.8-3.5; P = .82) and the mean coefficient of variation, by 3.3 (95% CI, 4.5-2.0; P = .65). At 1 day, the UCVA was 20/20 in 29% of cases, 20/20 to 20/40 in 58%, and 20/40 to 20/50 in 12%. Microcoaxial phacoemulsification was safely and effectively performed, achieving consistent and satisfactory postoperative outcomes.

  17. Intraoperative electron beam radiation therapy (IOEBRT) for carcinoma of the exocrine pancreas

    International Nuclear Information System (INIS)

    Dobelbower, R.R. Jr.; Konski, A.A.; Merrick, H.W. III; Bronn, D.G.; Schifeling, D.; Kamen, C.

    1991-01-01

    The abdominal cavities of 50 patients were explored in a specially constructed intraoperative radiotherapy operating amphitheater at the Medical College of Ohio. Twenty-six patients were treated with intraoperative and postoperative precision high dose external beam therapy, 12 with intraoperative irradiation but no external beam therapy, and 12 with palliative surgery alone. All but two patients completed the postoperative external beam radiation therapy as initially prescribed. The median survival time for patients treated with palliative surgery alone was 4 months, and that for patients treated with intraoperative radiotherapy without external beam therapy was 3.5 months. Patients undergoing intraoperative irradiation and external beam radiation therapy had a median survival time of 10.5 months. Four patients died within 30 days of surgery and two patients died of gastrointestinal hemorrhage 5 months posttreatment

  18. Intra-operative radiotherapy of malignant tumors: Past, present and perspectives

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Le Bourgeois, J.P.; Ganem, G.

    1986-01-01

    Intra-operative radiotherapy consists of electron or photon radiation which is used during the operative procedure. The treatment field is arranged very precisely after critical organs have been previously arranged out of the field. The target volume includes the remaining tumor which could not be removed surgically, and the surrounding tumor bed which is also felt to be high risk for recurrence. It is preferable to have as little tumor remaining as possible before the intra-operative treatment radiation is given. Intra-operative radiotherapy was developed less than a quarter century ago in Japon, and it was later used in U.S.A. The accumulated experience in Japan and U.S.A. is rewieved here. Intra-operative radiotherapy has only recently been introduced to France. The biology, physics and medical and technical problems of intra-operative therapy are discussed [fr

  19. Green technology meets ecotoxicology

    Directory of Open Access Journals (Sweden)

    Kristina Radošević

    2016-01-01

    Full Text Available By applying concept and principles of green chemistry into different technological processes, green technologies are developed. The environmental and economic benefits of “green” approach is achieved through several directions, such as the use of renewable raw materials, creation of economic efficiency, the use of alternative reaction conditions, as well as the application of non-conventional solvents. From the point view of green chemistry, alternative solvents, in order to be a “green“ substitution to hazardous organic solvents, should be: non-volatile, non-flammable, stabile, synthesized by an environmentally friendly procedure, nontoxic and biodegradable. The toxic impact of all newly synthesized chemicals, such as alternative solvents, could be determined by methods and techniques of ecotoxicology. Ecotoxicology, an interdisciplinary scientific field, can serve as a way of monitoring the greenness of the processes. In vivo and in vitro experiments are used to study the effects of chemicals on different levels of organizations, from molecules to communities and ecosystem. The usage of in vitro methods is encouraged by a scientific community and regulatory agencies as an alternative to in vivo studies in order to reduce the number of laboratory animals used in the toxicological studies. Therefore, in this paper we gave a brief overview on the usage of animal cell cultures within the field of green chemistry and technology.

  20. Labelling it green

    Energy Technology Data Exchange (ETDEWEB)

    Evans, S.; Brocklehurst, F. [ETSU, Didcot (United Kingdom)

    1998-12-31

    The first two rounds of contracts awarded through the NFFO will expire in December 1998. These generators will then be looking for new contracts to supply renewable electricity. Since these projects were initiated the renewable energy market has grown steadily, but it is still mainly restricted to the protected market within NFFO. Consumer interest has grown steadily too, fuelled by the emergence of green energy supply companies. Market research has indicated that consumers would like the choice of green electricity, what remains unclear is if they would exercise this choice and to what extent they might pay a premium price for the privilege. From September 1998 the phased introduction of domestic sector franchise de-regulation commences. In principle, consumers can purchase their electricity from any supplier. This provides a golden opportunity for green generation. To make the most of this opportunity generators and suppliers will need to clearly explain to the public what their product is, how it is different and how everyone benefits from its use. A major marketing issue will be to provide assurance to the general public, that for example, they can indeed purchase energy from a windfarm in Wales, despite living in areas other than Wales. The DTI is assisting the expansion of the green market into the domestic sector via funding a project which plans to deliver an accreditation scheme in September 1998. This will provide a means of verifying the green claims of generators/supply companies. (Author)

  1. Intraoperative Assessment of Esophagogastric Junction Distensibility During Laparoscopic Heller Myotomy.

    Science.gov (United States)

    DeHaan, Reece K; Frelich, Matthew J; Gould, Jon C

    2016-04-01

    We sought to characterize the changes in esophagogastric junction (EGJ) distensibility during Heller Myotomy with Dor fundoplication using the EndoFLIP device. Intraoperative distensibility measurements on 14 patients undergoing Heller myotomy with Dor fundoplication were conducted over an 18-month period. Minimum esophageal diameter, cross-sectional areas, and distensibility index were measured at 30 and 40 mL catheter volumes before myotomy, postmyotomy, and following Dor fundoplication. Distensibility index is defined as the narrowest cross-sectional area divided by the corresponding pressure expressed in mm/mm Hg. Heller myotomy was found to lead to significant changes in the distensibility characteristics of the EGJ. Minimum esophageal diameter and EGJ distensibility increased significantly with Heller myotomy.

  2. Videoscopic Heller Myotomy with Intraoperative Endoscopy Promotes Optimal Outcomes

    Science.gov (United States)

    Bloomston, Mark; Brady, Patrick

    2002-01-01

    Background and Objectives: Minimally invasive surgical techniques are applicable to achalasia, but the optimum approach to intraoperative assessment of adequacy of myotomy remains unestablished. We set out to show that videoscopic Heller myotomy with concurrent endoscopy ensures adequacy of myotomy while limiting postoperative clinically apparent reflux. Methods: Seventy-eight consecutive patients with achalasia underwent videoscopic Heller myotomy with concomitant endoscopy between 1992 and 1998. Fundoplication was not routinely undertaken. Results: Preoperative symptoms consisted of dysphagia (100%), emesis/regurgitation (68%), heartburn (58%), and postprandial chest pain (49%). Following myotomy, significant improvement (P Heller myotomy guides the extent and adequacy of myotomy. By utilizing a focused dissection with preservation of the natural antireflux mechanisms around the gastroesophageal junction and limiting the extent of myotomy along the cardia, postoperative reflux symptoms are minimized. We advocate concomitant endoscopy during Heller myotomy to guide myotomy and submit that routine fundoplication is clinically unnecessary. PMID:12113416

  3. Is current clinical practice modified about intraoperative breast irradiation?

    Science.gov (United States)

    Massa, Michela; Franchelli, Simonetta; Panizza, Renzo; Massa, Tiberio

    2016-04-01

    After the results obtained in the two randomized clinical trial, the ELIOT trial and the TARGIT-A trial, a heated debate is going on concerning the question of applying intraoperative radiotherapy (IORT) instead of postoperative whole breast irradiation (WBI) after breast conservative treatment. Currently, many centers are applying the IORT following the strict selection criteria dictated by the working groups American Society for Radiation Oncology (ASTRO) and Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) and monitoring the oncological outcome together with radiation toxicity on breast tissue. The clinical experience of the Geneva University Hospital regarding the use of the Intrabeam system is evaluated and compared with current evidences.

  4. Non-radiographic intraoperative fluorescent cholangiography is feasible

    DEFF Research Database (Denmark)

    Larsen, Søren S; Schulze, Svend; Bisgaard, Thue

    2014-01-01

    INTRODUCTION: Intraoperative fluorescent cholangiography (IFC) with concomitant fluorescent angiography was recently developed for non-invasive identification of the anatomy during laparoscopic cholecystectomy. The objective of this study was to assess the time required for routine-use of IFC...... and to evaluate the success rate of the procedures. MATERIAL AND METHODS: A total of 35 patients scheduled for laparoscopic cholecystectomy and operated by the same surgeon were consecutively enrolled. A standardised protocol with IFC including angiography was performed during laparoscopic cholecystectomy...... hepatic duct was identified by IFC in all patients. In 29 of the 35 patients (83%; 95% confidence interval: 71-96%), the cystic artery was visualised by fluorescent angiography. No adverse effects or complications were recorded. CONCLUSION: Routine-use of IFC with fluorescent angiography during...

  5. Intra-operative hearing monitoring methods in middle ear surgeries

    Directory of Open Access Journals (Sweden)

    Wei Ren

    2016-12-01

    Full Text Available Hearing loss is a condition affecting millions of people worldwide. Conductive hearing loss (CHL is mainly caused by middle ear diseases. The low frequency area is the pivotal part of speech frequencies and most frequently impaired in patients with CHL. Among various treatments of CHL, middle ear surgery is efficient to improve hearing. However, variable success rates and possible needs for prolonged revision surgery still frustrate both surgeons and patients. Nowadays, increasing numbers of researchers explore various methods to monitor the efficacy of ossicular reconstruction intraoperatively, including electrocochleography (ECochG, auditory brainstem response (ABR, auditory steady state response (ASSR, distortion product otoacoustic emissions (DPOAE, subjective whisper test, and optical coherence tomography (OCT. Here, we illustrate several methods used clinically by reviewing the literature.

  6. Upper gastrointestinal tract injuries by intraoperative radiotherapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, I; Isawa, T; Satomi, T; Tazima, T [Tokyo Metropolitan Komagome Hospital (Japan)

    1981-08-01

    Twenty-one patients with unresectable carcinoma of the pancreas were treated by intraoperative irradiation with a large electron dose of 1500 - 3000 rads and upper gastrointestinal complications were encountered in five cases. All of those five cases were for carcinoma of the pancreatic head, and were seen for gastrointestinal tract injuries of the duodenum as follows, gastric ulcer in 2 cases, ulcer of the 1st duodenal portion in one case and ulcer with severe stenosis of the 2nd or 3rd duodenal portion in one case, respectively. Endoscopic features of these postirradiation gastrointestinal ulcers were characterized by deep, punched-out ulcers with grayish bases and sharp margins. Clinically these ulcers and stenosis were very difficult to treat, so by-pass operations were performed in two cases, resulting in prolonged survival.

  7. Intraoperative radiation in the canine para-aortic abdomen

    International Nuclear Information System (INIS)

    Hoopes, P.J.; Gillette, E.L.

    1984-01-01

    Twenty adult beagle dogs received intraoperatively delivered 6 MeV electrons to the para-aortic abdomen and bladder. The dogs were equally divided into 4 dose groups receiving 22 Gy, 30 Gy, 38.5 Gy and 47 Gy. The 5 cm x 8 cm radiation field included a variable portion of the left kidney, the left ureter, the abdominal aorta and vena cava, the base of the bladder and the left sciatic and femoral nerves. The lesions observed were fibroelastic proliferation of the aortic intima, severe renal atrophy and fibrosis, ureteral stenosis, bladder fibrosis and demyelinating peripheral neuropathies. Histologic, morphometric and dose response analyses are compared with responses of dogs receiving more conventional fractionated doses to a total of 60 Gy, 70 Gy or 80 Gy x-ray in 6 weeks

  8. Postprocessing algorithm for automated analysis of pelvic intraoperative neuromonitoring signals

    Directory of Open Access Journals (Sweden)

    Wegner Celine

    2016-09-01

    Full Text Available Two dimensional pelvic intraoperative neuromonitoring (pIONM® is based on electric stimulation of autonomic nerves under observation of electromyography of internal anal sphincter (IAS and manometry of urinary bladder. The method provides nerve identification and verification of its’ functional integrity. Currently pIONM® is gaining increased attention in times where preservation of function is becoming more and more important. Ongoing technical and methodological developments in experimental and clinical settings require further analysis of the obtained signals. This work describes a postprocessing algorithm for pIONM® signals, developed for automated analysis of huge amount of recorded data. The analysis routine includes a graphical representation of the recorded signals in the time and frequency domain, as well as a quantitative evaluation by means of features calculated from the time and frequency domain. The produced plots are summarized automatically in a PowerPoint presentation. The calculated features are filled into a standardized Excel-sheet, ready for statistical analysis.

  9. Trading green electricity

    International Nuclear Information System (INIS)

    Davies, M.

    1997-01-01

    A study has been carried out into the feasibility of developing an electricity trading mechanism which would allow consumers to purchase electricity which has been derived from renewable energy resources. This study was part funded by the European Commission (ALTENER), the Department of Trade and Industry and a number of private sector companies. The trading mechanism is known as the Green Pool. As a result of the findings of this study discussions are being held with potential generators and suppliers to establish a Green Pool plc. The aim is to encourage the development of new renewable energy projects outside the NFFO and SRO schemes. The Green Pool plc will be owned by the generators and its main objective will be to market the electricity produced by its members. (Author)

  10. Certified: green power

    International Nuclear Information System (INIS)

    Rhodes, S.; Brown, L.

    1999-01-01

    Deregulation of the energy industry in the USA may be a force favouring the environment but for the consumer it is something of a nightmare since there are so many options with respect to both price, service and environmental awareness. However, there is now a marked tendency for companies wishing to be seen as 'green' to favour environmentally aware suppliers. Indeed, some suppliers holding formal qualifications in 'greenness' believe they are justified in charging a premium for their energy. The question is asked 'what is green?' and the authors discuss the answers at some length: the hydro industry fares well in such a discussion. The authors (from Scientific Certification Systems) believe that certification provides a rational explanation of prices and why charging a premium may be justifiable.(UK)

  11. GREEN BANKING IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Dumitrascu Mihaela

    2014-07-01

    Full Text Available The paper investigates the green banking in Romania, a new approach of conducting the banking business through considering the corporate social responsibility and environmental aspects. Nowadays, it is difficult to face the globalization and competition in order to asssure the implementation of the green banking practices. The aim of the present study is to identify corporations that have sustainability concerns. To achieve this objective, we set some hypothesis and after this we showed that the corporations are more likely to be included in the list of top banks in the world. Our study is relevant for future research in this area, because of the importance of such aspects in corporations nowadays.The conclusions of our study is that green banking practices in Romania is in an incipient stage

  12. Green Logistics Management

    Science.gov (United States)

    Chang, Yoon S.; Oh, Chang H.

    Nowadays, environmental management becomes a critical business consideration for companies to survive from many regulations and tough business requirements. Most of world-leading companies are now aware that environment friendly technology and management are critical to the sustainable growth of the company. The environment market has seen continuous growth marking 532B in 2000, and 590B in 2004. This growth rate is expected to grow to 700B in 2010. It is not hard to see the environment-friendly efforts in almost all aspects of business operations. Such trends can be easily found in logistics area. Green logistics aims to make environmental friendly decisions throughout a product lifecycle. Therefore for the success of green logistics, it is critical to have real time tracking capability on the product throughout the product lifecycle and smart solution service architecture. In this chapter, we introduce an RFID based green logistics solution and service.

  13. Why Green Taxation

    DEFF Research Database (Denmark)

    Hjøllund, Lene; Svendsen, Gert Tinggaard

    2001-01-01

    According to economists solving environmental problems is simple. Politicians should simply impose a uniform tax on harmful emissions. However, the actual design of such green taxation shows that politicians do not follow their advice. CO2 taxation in OECD, for example, is highly differentiated...... and much in favour of industry. In fact, CO2 tax rates for industry are, on average, six times lower than those for households. We argue that the reason for this tax differentiation is that industry, in contrast to households, has a strong capability to lobby. Therefore, green taxation is effectively...... blocked and the desired environmental results are not being achieved. Why then is green taxation persistently applied in relation to industry? We argue that strong fiscal incentives drive this policy choice at the expense of environmental concerns because it allows environmental bureaucracies to budget-maximize....

  14. Tolerance of canine anastomoses to intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Tepper, J.E.; Sindelar, W.; Travis, E.L.; Terrill, R.; Padikal, T.

    1983-01-01

    Radiation has been given intraoperatively to various abdominal structures in dogs, using a fixed horizontal 11 MeV electron beam at the Armed Forces Radiobiologic Research Institute. Animals were irradiated with single doses of 2000, 3000 and 4500 rad to a field which extended from the bifurcation of the aorta to the rib cage. All animals were irradiated during laparotomy under general anesthesia. Because the clinical use of intraoperative radiotherapy in cancer treatment will occasionally require irradiation of anastomosed large vessels and blind loops of bowel, the tolerance of aortic anastomoses and the suture lines of blind loops of jejunum to irradiation were studied. Responses in these experiments were scored at times up to one year after irradiation. In separate experiments both aortic and intestinal anastomoses were performed on each animal for evaluation of short term response. The dogs with aortic anastomoses showed adequate healing at all doses with no evidence of suture line weakening. On long-term follow-up one animal (2000 rad) had stenosis at the anastomosis and one animal (4500 rad) developed an arteriovenous fistula. Three of the animals that had an intestinal blind loop irradiated subsequently developed intussusception, with the irradiated loop acting as the lead point. One week after irradiation, bursting pressure of an intestinal blind loop was normal at 3000 rad, but markedly decreased at 4500 rad. No late complications were noted after the irradiation of the intestinal anastomosis. No late complicatons were observed after irradiation of intestinal anastomoses, but one needs to be cautious with regards to possible late stenosis at the site of an irradiated vascular anastomosis

  15. VATS intraoperative tattooing to facilitate solitary pulmonary nodule resection

    Directory of Open Access Journals (Sweden)

    Boutros Cherif

    2008-03-01

    Full Text Available Abstract Introduction Video-assisted thoracic surgery (VATS has become routine and widely accepted for the removal of solitary pulmonary nodules of unknown etiology. Thoracosopic techniques continue to evolve with better instruments, robotic applications, and increased patient acceptance and awareness. Several techniques have been described to localize peripheral pulmonary nodules, including pre-operative CT-guided tattooing with methylene blue, CT scan guided spiral/hook wire placement, and transthoracic ultrasound. As pulmonary surgeons well know, the lung and visceral pleura may appear featureless on top of a pulmonary nodule. Case description This paper presents a rapid, direct and inexpensive approach to peripheral lung lesion resection by marking the lung parenchyma on top of the nodule using direct methylene blue injection. Methods In two patients with peripherally located lung nodules (n = 3 scheduled for VATS, we used direct methylene blue injection for intraoperative localization of the pulmonary nodule. Our technique was the following: After finger palpation of the lung, a spinal 25 gauge needle was inserted through an existing port and 0.1 ml of methylene blue was used to tattoo the pleura perpendicular to the localized nodule. The methylene blue tattoo immediately marks the lung surface over the nodule. The surgeon avoids repeated finger palpation, while lining up stapler, graspers and camera, because of the visible tattoo. Our technique eliminates regrasping and repalpating the lung once again to identify a non marked lesion. Results Three lung nodules were resected in two patients. Once each lesion was palpated it was marked, and the area was resected with security of accurate localization. All lung nodules were resected in totality with normal lung parenchymal margins. Our technique added about one minute to the operative time. The two patients were discharged home on the second postoperative day, with no morbidity. Conclusion

  16. Green Chemistry Pedagogy

    Science.gov (United States)

    Kolopajlo, Larry

    2017-02-01

    This chapter attempts to show how the practice of chemistry teaching and learning is enriched by the incorporation of green chemistry (GC) into lectures and labs. To support this viewpoint, evidence from a wide range of published papers serve as a cogent argument that GC attracts and engages both science and nonscience students, enhances chemistry content knowledge, and improves the image of the field, while preparing the world for a sustainable future. Published pedagogy associated with green and sustainable chemistry is critically reviewed and discussed.

  17. GREEN CORE HOUSE

    Directory of Open Access Journals (Sweden)

    NECULAI Oana

    2017-05-01

    Full Text Available The Green Core House is a construction concept with low environmental impact, having as main central element a greenhouse. The greenhouse has the innovative role to use the biomass energy provided by plants to save energy. Although it is the central piece, the greenhouse is not the most innovative part of the Green Core House, but the whole building ensemble because it integrates many other sustainable systems as "waste purification systems", "transparent photovoltaic panels" or "double skin façades".

  18. Green in software engineering

    CERN Document Server

    Calero Munoz, Coral

    2015-01-01

    This is the first book that presents a comprehensive overview of sustainability aspects in software engineering. Its format follows the structure of the SWEBOK and covers the key areas involved in the incorporation of green aspects in software engineering, encompassing topics from requirement elicitation to quality assurance and maintenance, while also considering professional practices and economic aspects. The book consists of thirteen chapters, which are structured in five parts. First the "Introduction" gives an overview of the primary general concepts related to Green IT, discussing wha

  19. Green Chemistry Metrics with Special Reference to Green Analytical Chemistry

    OpenAIRE

    Marek Tobiszewski; Mariusz Marć; Agnieszka Gałuszka; Jacek Namieśnik

    2015-01-01

    The concept of green chemistry is widely recognized in chemical laboratories. To properly measure an environmental impact of chemical processes, dedicated assessment tools are required. This paper summarizes the current state of knowledge in the field of development of green chemistry and green analytical chemistry metrics. The diverse methods used for evaluation of the greenness of organic synthesis, such as eco-footprint, E-Factor, EATOS, and Eco-Scale are described. Both the well-establis...

  20. Sustainable house construction and green financing. Explanation for 'green mortgages'

    International Nuclear Information System (INIS)

    1997-05-01

    The Dutch government finances the sustainable construction of new houses by means of so-called 'green loans'. Extra costs for the construction of a sustainable house are compensated by a lower interest rate for a green loan. In this brochure it is explained when green financing of house construction is possible and how to apply for such loans

  1. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve: histopathological and morphometric studies

    International Nuclear Information System (INIS)

    Vujaskovic, Zeljko; Powers, Barbara E.; Paardekoper, Gabriel; Gillette, Sharon M.; Gillette, Edward L.; Colacchio, Thomas A.

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate histopathological and histomorphometric changes in the sciatic nerve of dogs, after IORT with or without hyperthermia treatment. Methods and Materials: Young adult beagle dogs were randomized into five groups of 3-5 dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy. Six groups of 4-5 dogs each received IORT doses of 12, 16, 20, 24, or 28 Gy simultaneously with 44 deg. C of intraoperative hyperthermia (IOHT) for 60 min. One group of dogs acted as hyperthermia-alone controls. Two years after the treatment, dogs were euthanized, and histopathological and morphometric analyses were performed. Results: Qualitative histological analysis showed prominant changes such as focal necrosis, mineralization, fibrosis, and severe fiber loss in dogs which received combined treatment. Histomorphometric results showed a significantly higher decrease in axon and myelin and small blood vessels, with a corresponding increase in connective tissue in dogs receiving IORT plus hyperthermia treatment. The effective dose for 50% of nerve fiber loss (ED 50 ) in dogs exposed to IORT only was 25.3 Gy. The ED 50 for nerve fiber loss in dogs exposed to IORT combined with IOHT was 14.8 Gy. The thermal enhancement ratio (TER) was 1.7. Conclusion: The probability of developing peripheral neuropathies in a large animal model is higher when IORT is combined with IOHT, when compared to IORT application alone. To minimize the risk of peripheral neuropathy, clinical treatment protocols for the combination of IORT and hyperthermia should not assume a thermal enhancement ratio (TER) to be lower than 1.5

  2. Plants as green phones

    NARCIS (Netherlands)

    Soler, R.; Harvey, J.A.; Bezemer, T.M.; Stuefer, J.F.

    2008-01-01

    Plants can act as vertical communication channels or `green phones¿ linking soil-dwelling insects and insects in the aboveground ecosystem. When root-feeding insects attack a plant, the direct defense system of the shoot is activated, leading to an accumulation of phytotoxins in the leaves. The

  3. Putting on the green

    Science.gov (United States)

    The green chemistry movement is scrutinized for marks of tangible success in this short perspective. Beginning with the easily identified harm of the Union Carbide Bhopal, India disaster and the concerns of Love Canal site in Niagara Falls, NY the public can begin to more easily ...

  4. Green, Brown, and probability

    CERN Document Server

    Chung, Kai Lai

    1995-01-01

    This volume shows modern probabilistic methods in action: Brownian Motion Process as applied to the electrical phenomena investigated by Green et al., beginning with the Newton-Coulomb potential and ending with solutions by first and last exits of Brownian paths from conductors.

  5. Why Green Taxation

    DEFF Research Database (Denmark)

    Hjøllund, Lene; Svendsen, Gert Tinggaard

    2001-01-01

    According to economists solving environmental problems is simple. Politicians should simply impose a uniform tax on harmful emissions. However, the actual design of such green taxation shows that politicians do not follow their advice. CO2 taxation in OECD, for example, is highly differentiated...

  6. News: Green Chemistry & Technology

    Science.gov (United States)

    A series of 21 articles focused on different features of green chemistry in a recent issue of Chemical Reviews. Topics extended over a wide range to include the design of sustainable synthetic processes to biocatalysis. A selection of perspectives follows as part of this colu

  7. The Green Obligation

    Science.gov (United States)

    Adams, Cameron

    2007-01-01

    As the green movement grows, studies provide conclusive evidence about the benefits of environmentally conscious practices indoors and outdoors. Schools are no exception. Many of these studies demonstrate how poor indoor air quality (IAQ) in schools adversely affects many of the nation's 55 million students with health problems such as asthma and…

  8. A green chemistry approach

    Indian Academy of Sciences (India)

    Administrator

    One-pot synthesis of quinaldine derivatives by using microwave irradiation without any solvent – A green chemistry approach. JAVAD SAFARI*, SAYED HOSSEIN BANITABA and SEPEHR SADEGH SAMIEI. Department of Chemistry, The Faculty of sciences, University of Kashan, Kashan,. P.O. Box 87317-51167, I.R. Iran.

  9. Between green and grey

    NARCIS (Netherlands)

    Jeanet Kullberg

    2016-01-01

    Original title: Tussen groen en grijs Taking cuttings is cool. Growing vegetables is all the rage. Green oases can now be found scattered throughout Dutch towns and cities: community gardens and roof gardens where residents can go to relax and enjoy themselves, improve the appearance of their

  10. Developing Green Line Products

    DEFF Research Database (Denmark)

    Muñoz-Marin, Ana Maria; Lassen, Astrid Heidemann; Poulsen, Søren Bolvig

    2011-01-01

    This publication is based on the Master thesis “User-driven ecoinnovation process: Towards the implementation of the Green product line at JELD-WEN” written by Ana Maria Muñoz-Marin as her Graduation Project for the MSc. Global Innovation Management degree. The company-based experiment was carried...

  11. Being 'green' helps profitability?

    International Nuclear Information System (INIS)

    Austin, D.

    1999-01-01

    Pollution reduction beyond regulatory compliance is gaining momentum among firms, but managers ask if being 'green' helps profitability. Evidence suggests it doesn't hurt, but when we see environmentally attractive firms with sound financial performance, it cannot yet say which is cause and which is effect [it

  12. Lean Green Machines

    Science.gov (United States)

    Villano, Matt

    2011-01-01

    Colleges and universities have been among the leaders nationwide in adopting green initiatives, partly due to their demographics, but also because they are facing their own budget pressures. Virtualization has become the poster child of many schools' efforts, because it provides significant bang for the buck. However, more and more higher…

  13. Greening China Naturally

    Science.gov (United States)

    Shixiong Cao; Ge Sun; Zhiqiang Zhang; Liding Che; Qi Feng; et. al.

    2011-01-01

    China leads the world in afforestation, and is one of the few countries whose forested area is increasing. However, this massive “greening” effort has been less effective than expected; afforestation has sometimes produced unintended environmental, ecological, and socioeconomic consequences, and has failed to achieve the desired ecological benefits. Where afforestation...

  14. Nanoreactors for green catalysis

    NARCIS (Netherlands)

    de Martino, M.T.; Abdelmohsen, L.K.E.A.; Rutjes, Floris P.J.T.; van Hest, J.C.M.; Hessel, V.

    2018-01-01

    Sustainable and environmentally benign production are key drivers for developments in the chemical industrial sector, as protecting our planet has become a significant element that should be considered for every industrial breakthrough or technological advancement. As a result, the concept of green

  15. Green Maritime Logistics

    DEFF Research Database (Denmark)

    Psaraftis, Harilaos N.

    2016-01-01

    By green maritime logistics we mean achieving an acceptable environmental performance of the maritime transport logistical supply chain while at the same time respecting traditional economic criteria. In this paper the environmental focus is on maritime emissions. Achieving such goal may involve ...

  16. Green Software Products

    NARCIS (Netherlands)

    Jagroep, E.A.

    2017-01-01

    The rising energy consumption of the ICT industry has triggered a quest for more green, energy efficient ICT solutions. The role of software as the true consumer of power and its potential contribution to reach sustainability goals has increasingly been acknowledged. At the same time, it is shown to

  17. Frobenius Green functors

    OpenAIRE

    Baker, Andrew

    2012-01-01

    These notes provide an informal introduction to a type of Mackey functor that arises naturally in algebraic topology in connection with Morava $K$-theory of classifying spaces of finite groups. The main aim is to identify key algebraic aspects of the Green functor structure obtained by applying a Morava $K$-theory to such classifying spaces.

  18. Global Green Growth Institute

    DEFF Research Database (Denmark)

    Müller, Anders Riel

    2017-01-01

    Har man fulgt historien om Venstres gruppeformand Lars Løkkes rejser på 1. klasse i forbindelse med formandsposten for Global Green Growth Institute (GGGI) er der sikkert nogle der undrer sig over, hvad GGGI er for en størrelse. Medierne præsenterer GGGI som en international klimaorganisation, der...

  19. Green Building Tools for Tribes

    Science.gov (United States)

    Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.

  20. Green Manufacturing Fundamentals and Applications

    CERN Document Server

    2013-01-01

    Green Manufacturing: Fundamentals and Applications introduces the basic definitions and issues surrounding green manufacturing at the process, machine and system (including supply chain) levels. It also shows, by way of several examples from different industry sectors, the potential for substantial improvement and the paths to achieve the improvement. Additionally, this book discusses regulatory and government motivations for green manufacturing and outlines the path for making manufacturing more green as well as making production more sustainable. This book also: • Discusses new engineering approaches for manufacturing and provides a path from traditional manufacturing to green manufacturing • Addresses regulatory and economic issues surrounding green manufacturing • Details new supply chains that need to be in place before going green • Includes state-of-the-art case studies in the areas of automotive, semiconductor and medical areas as well as in the supply chain and packaging areas Green Manufactu...

  1. Benefits of Green Power Partnership

    Science.gov (United States)

    The U.S. EPA's Green Power Partnership is a voluntary partnership program designed to reduce the environmental impact of electricity generation by promoting renewable energy. Learn about the benefits of becoming a Green Power Partner.

  2. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  3. The green highway forum

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    In late 2004, as part of American Coal Ash Association's (ACAA) strategic planning process, a plan was approved by its Board of Directors implementing a 'green highways' concept which emphasized use of coal combustion products (CCPs) in highways in a variety of ways including being used alone, in combination with other forms of CCPs, and combined with non ash materials. The incentives behind the developed concept were the derived advantages from beneficial technical economic and environmental impacts. Although the primary use of fly ash is concrete, other forms of CCPs could be considered for more non-traditional highway applications. For example, these might include soils stabilization, binders for in-place pavement recycling, use in flowable fills, aggregates, source materials for structural fills and embankments, components in manufactured soils, and for granular base courses beneath pavements. At this same time, unknown to ACCA, EPA Region 3 in Philadelphia was working with the Wetlands and Watershed Work Group, a non-profit organization involved in wetlands policy and management along with the Federal Highway Administration (FHWA) on their own Green Highways initiative. These groups were planning a conference, the 'Green Highway Forum'. This was held in College Park, Maryland at the University of Maryland, Nov 8-10 2005. At the conference a draft 'roadmap' was presented as a guide to executive level participants bringing the diverse viewpoints of many agencies and interest groups together. Ten guiding principals were considered. The 'Green Highways' is a new effort to recognize the 'greenness' of many projects already completed and those to be initiated. 2 photos.

  4. Green function on product networks

    OpenAIRE

    Arauz Lombardía, Cristina; Carmona Mejías, Ángeles; Encinas Bachiller, Andrés Marcos

    2012-01-01

    Our objective is to determine the Green function of product networks in terms of the Green function of one of the factor networks and the eigenvalues and eigenfunctions of the Schr odinger operator of the other factor network, which we consider that are known. Moreover, we use these results to obtain the Green function of spider networks in terms of Green functions over cicles and paths. Peer Reviewed

  5. GREEN PACKAGING, GREEN PRODUCT, GREEN ADVERTISING, PERSEPSI, DAN MINAT BELI KONSUMEN

    Directory of Open Access Journals (Sweden)

    Imam Santoso

    2016-12-01

    Full Text Available Environmental problems become one of the strategic issues in achieving global competitiveness. One of the issues is products that are made from environmental friendly materials or known as green product. Furthermore, in green products marketing, the company also uses green packaging and green advertising concept. This study aimed to analyze the effect of green packaging, green products, and green advertising on consumer perception and purchasing intention. The study was conducted in Ketawanggede Village, Lowokwaru Sub-district, Malang City. The sampling method used nonprobability accidential sampling techniques. The numbers of respondents were 113 consumers in study site. Data were collected by interview using questionnaires. The method of analysis used Generalized Structured Component Analysis (GSCA. The analysis showed that the green packaging, green products, and green advertising had positive significant influence on consumer perceptions. Meanwhile, green product and consumer perception had positive significant influence on purchasing interest, but the green packaging and green advertising has not found sufficient evidence in influencing purchasing intention.

  6. It's Not Easy Building Green.

    Science.gov (United States)

    Higgins, Joseph

    2003-01-01

    Discusses green buildings, facilities designed, constructed, and operated in an environmentally friendly and resource-efficient way. Discusses reasons for campuses to "go green," the "shades of green" or variations in environmental-friendliness, certification through the Leadership in Energy and Environmental Design (LEED) rating system, financial…

  7. Green mortgages in the Netherlands

    International Nuclear Information System (INIS)

    Bosch, N.

    1997-01-01

    Since November 1996 sustainable building of houses is also part of the fiscal Regulation for Green Projects (i.e. the stimulation of environment-friendly investments). The extension of that financial regulation resulted in a new product: Green Mortgages. The conditions that have to be met to be qualified for a Green Mortgage are briefly outlined

  8. Green economy and related concepts

    NARCIS (Netherlands)

    Loiseau, Eleonore; Saikku, Laura; Antikainen, Riina; Droste, Nils; Hansjürgens, Bernd; Pitkänen, Kati; Leskinen, Pekka; Kuikman, Peter; Thomsen, Marianne

    2016-01-01

    For the last ten years, the notion of a green economy has become increasingly attractive to policy makers. However, green economy covers a lot of diverse concepts and its links with sustainability are not always clear. In this article, we focus on definitions of green economy and related concepts

  9. Guide to Purchasing Green Power

    Science.gov (United States)

    The Guide for Purchasing Green Power is a comprehensive guide for current and potential buyers of green power with information about green power purchasing. The Guide is created cooperatively between the EPA, the U.S. Department of Energy, the World Resou

  10. Investing in a green future

    Science.gov (United States)

    Clapp, Christa

    2018-01-01

    The growing green bond market reflects the financial sector's awakening to climate risk. New research examining the US municipal bond market suggests a positive green bond premium in recent years, driven by differences in credit quality. As climate-risk disclosure becomes more widespread, investors may show willingness to pay green premiums.

  11. Green Roofs for Stormwater Management

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Results indicate that the green roofs are capable of removing 40% of the annual rainfall volume from a roof through retention and evapotranspiration. Rainfall not retained by green roofs is detained, effectively...

  12. Quantitative analysis of intraoperative communication in open and laparoscopic surgery.

    Science.gov (United States)

    Sevdalis, Nick; Wong, Helen W L; Arora, Sonal; Nagpal, Kamal; Healey, Andrew; Hanna, George B; Vincent, Charles A

    2012-10-01

    -risk procedure (average, 2 communications/min). In the observed cases, surgeons actively directed and led OR teams in the intraoperative phase. The lack of communication between surgeons and anesthesiologists ought to be evaluated further. Simple, inexpensive interventions shown to streamline intraoperative communication and teamworking (preoperative briefing, surgeons' mental practice) should be considered further.

  13. Green Consumerism : an Eco-Friendly Behaviour Form Through The Green Product Consumption and Green Marketing

    OpenAIRE

    Handayani, Wiwik

    2017-01-01

    This research is referred to analyse the influence of consumer attitude of green product towards purchase intention. The consumer attitude of green product is a psychological tendencies that is expressed by evaluating a certain entity with some advantage or disadvantage considerations. The problem of this research is the low of cunsumer awareness to consume green product, because the lack to comprehend the importance of green product usage for health and eco-friendly. The purpose of this rese...

  14. Green roofs; Les toitures vegetalisees

    Energy Technology Data Exchange (ETDEWEB)

    Seghier, C.

    2006-03-15

    Impervious surface coverage keeps spreading in cities. Streets, sidewalks, parking lots and roofs are waterproof, meaning greater amounts of water to channel and treat and higher flood risks during heavy rainfalls. Green roofing can play a key part in addressing this alarming issue. There are three types of green roofs: extensive, semi-intensive and intensive. The extensive green roof technique uses a thin soil covering with a variety of species providing year-round plant coverage. The plants are not necessarily horticultural in which case routine maintenance is minimal. No watering is needed. Usually extensive green roofs create an ecosystem. The semi-intensive green roof technique uses a soil covering of average thickness and serves to create decorative roofing. Although maintenance is moderate, watering is essential. The intensive green roof technique produces a terrace roof garden. Another advantage of green roofs is they increase the life cycle of the sealing. Roof sealing protection may see the span of its life cycle, now at about fifteen years, doubled if the building has a green roof. planning professionals still know very little about green roofing solutions. Yet, green roofing provides unquestionable ecological qualities and thermal and acoustic performance that have proven to be environmentally friendly. Yet France lags behind northern European countries in green roofing. The Germans, Swiss, Austrians, Scandinavians and Dutch have been using the technique for more than twenty years. (A.L.B.)

  15. Green buildings pay

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Edwards, Brian

    The new edition of ‘Green Buildings Pay’ authored by Brian Edwards and Emanuele Naboni explores the business and professional benefits which derive from architectural design driven by sustainability. With a new sub-title ‘Green Buildings Pay: design, productivity and ecology’ the book argues...... that environmental design has altered how we design, construct and manage buildings. The book has relevance to those who not only design and engineer buildings but to those who commission architecture and those who occupy the products of this process. Hence, the user is a key consideration. The book examines via...... a number of LEED and BREEAM cases the buildings which flow from corporate environmental responsibility. A number of office and university buildings are examined from three main perspectives- the architect, client and user. One key finding is that architectural innovation has been driven by ecological...

  16. The green protest

    International Nuclear Information System (INIS)

    Brun, R.

    1978-01-01

    The increasing public interest in the 'green' and the 'coloured' made the politicians alert. The ecological movement and the public initiatives show their effects. What 'utopists', 'crazy people' think about large technical development gains public importance. The uneasiness about a social development which was directed only by increasing spending power and permanent expansion, begins to articulate itself. Values such as solidarity and community, considerateness for fellow men and environment which had been eliminated in the past, are regaining their meaning. From the point of view of this steadily increasing movement, the phenomenon of the 'green parties' is investigated. In this context, the persons involved give their opinions, as well as representatives of the established parties, thus giving this volume the character of a documentation on an important trend in today's events. (orig.) [de

  17. Green and lean management

    CERN Document Server

    Davim, J

    2017-01-01

    This book focusses on the challenges and changes organizational management faces in an era when the need to develop environmentally aware processes meets high levels of competition. It covers the synergetic effects, how re-use, recycling, waste reduction, and other sustainable production strategies can add value, low costs and time of production. Sustainable business behavior is not only an environmental perspective on management, but more and more contains an organizational perspective. Taking into account these issues, green and lean management appears as the way managers can drive their employees to continuously improve the management processes that add value to the organization and costumers. This book provides information on principles, strategies, models, and applications of green and lean management, and at the same time communicates the latest research activity relating to this scientific field world-wide.

  18. Towards green construction

    International Nuclear Information System (INIS)

    Bajracharya, Bijaya B.; Shrestha, Prasanna M.

    2000-01-01

    Sustainability is the key to any development works. In the operation phase, hydro power is the most sustainable form of energy. However construction activities for the same power station are usually far from being green. The popular myth is that construction activity converts green into grey. Despite this popular myth, construction of a hydro power project in Nepal has made the project area greener than earlier during the construction phase itself. Choice of construction technology, appropriate level of environmental impact assessment, monitoring of environmental parameters along side the construction progress followed by mitigation at the right time; launching community development programmes side by side, having environmental specification in contractual documents and self-reliance to fulfill environmental obligations by contractors itself are the key factors in the environmental management within the construction activities. The main conclusions in the paper is the need to change the way to think about the project constraints

  19. Intraoperative Tumor Perforation is Associated with Decreased 5-Year Survival in Colon Cancer

    DEFF Research Database (Denmark)

    Bundgaard, N S; Bendtsen, V O; Ingeholm, P

    2017-01-01

    BACKGROUND: It is a widely held belief that intraoperative tumor perforation in colon cancer impairs survival and causes local recurrence, although the prognostic importance remains unclear. AIM: The aim of this study was to assess the effect of unintended intraoperative tumor perforation...... on postoperative mortality and long-term survival. MATERIAL AND METHODS: This national cohort study was based on data from a prospectively maintained nationwide colorectal cancer database. We included 16,517 colon cancer patients who were resected with curative intent from 2001 to 2012. RESULTS: Intraoperative...... tumor perforation produced a significantly impaired 5-year survival of 40% compared to 64% in non-perforated colon cancer. Intraoperative tumor perforation was an independent risk factor for death, hazard ratio 1.63 (95% confidence interval: 1.4-1.94), with a significantly increased 90-day postoperative...

  20. Single high dose intraoperative electrons for advanced stage pancreatic cancer: Phase I pilot study

    International Nuclear Information System (INIS)

    Goldson, A.L.; Ashaveri, E.; Espinoza, M.C.

    1981-01-01

    Phase I toxicity studies with intraoperative radiotherapy proved to be a feasible adjunct to surgery for unresectable malignancies of the pancreas at Howard University Hospital. There have been minimal side effects or complications related to the combination of limited surgical decompression and intraoperative radiotherapy alone. The toxic effects of intraoperative radiotherapy on normal tissues is being assessed on a dose volume basis. Doses of 2000 to 2500 rad in a single exposure to include the pancreas, regional nodes and duodenum are acceptable if the total treatment volume is less than or equal to 100 cm. The tumoricidal effects on the cancer are demonstratable when one reviews the pathological specimens that illustrate massive tumor necrosis and fibros replacement, but in all cases reviewed, viable cancer was noted. Intraoperative radiotherapy, therefore, represents a significant boost dose for resectable, partially resectable or non-resectable tumors when added to conventional external beam irradiation and/or chemotherapy. Preliminary clinical data and minimal toxicity justifies further investigation