WorldWideScience

Sample records for intrafractional tumour position

  1. Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung

    International Nuclear Information System (INIS)

    Worm, Esben S.; Hansen, Anders T.; Petersen, Joergen B.; Muren, Ludvig P.; Praestegaard, Lars H.; Hoeyer, Morten

    2010-01-01

    Background. Localisation errors in cone-beam CT (CBCT) guided stereotactic body radiation therapy (SBRT) were evaluated and compared to positioning using the external coordinates of a stereotactic body frame (SBF) alone. Possible correlations to patient- or treatment-specific factors such as body mass index (BMI), planning time, treatment delivery time, and distance between tumour and spinal cord were explored to determine whether they influenced on the benefit of image-guidance. Material and methods. A total of 34 patients received SBRT (3 fractions) for tumours in the liver (15 patients) or the lung (19 patients). Immobilisation and positioning was obtained with a SBF. Pre- and post-treatment CBCT scans were registered with the bony anatomy of the planning CT to find inter- and intrafractional patient positioning errors (PPE). For lung tumour patients, matching was also performed on the tumours to find the tumour positioning errors (TPE) and baseline shifts relative to bony anatomy. Results. The mean inter- and intrafractional 3D vector PPE was 4.5 ± 2.7 mm (average ± SD) and 1.5 ± 0.6 mm, respectively, for the combined group of patients. For lung tumours, the interfractional misalignment was 5.6 ± 1.8 mm. The baseline shift was 3.9 ± 2.0 mm. Intrafractional TPE and baseline shifts were 2.1 ± 0.7 mm and 1.9 ± 0.6 mm, respectively. The magnitude of interfractional baseline shift was closely correlated with the distance between the tumour and the spinal cord. Intrafractional errors were independent of patient BMI, age or gender. Conclusion. Image-guidance reduced setup errors considerably. The study demonstrated the benefit of CBCT-guidance regardless of patient specific factors such as BMI, age or gender. Protection of the spinal cord was facilitated by the correlation between the tumour position relative to the spinal cord and the magnitude of baseline shift.

  2. Prediction of lung tumour position based on spirometry and on abdominal displacement: Accuracy and reproducibility

    International Nuclear Information System (INIS)

    Hoisak, Jeremy D.P.; Sixel, Katharina E.; Tirona, Romeo; Cheung, Patrick C.F.; Pignol, Jean-Philippe

    2006-01-01

    Background and purpose: A simulation investigating the accuracy and reproducibility of a tumour motion prediction model over clinical time frames is presented. The model is formed from surrogate and tumour motion measurements, and used to predict the future position of the tumour from surrogate measurements alone. Patients and methods: Data were acquired from five non-small cell lung cancer patients, on 3 days. Measurements of respiratory volume by spirometry and abdominal displacement by a real-time position tracking system were acquired simultaneously with X-ray fluoroscopy measurements of superior-inferior tumour displacement. A model of tumour motion was established and used to predict future tumour position, based on surrogate input data. The calculated position was compared against true tumour motion as seen on fluoroscopy. Three different imaging strategies, pre-treatment, pre-fraction and intrafractional imaging, were employed in establishing the fitting parameters of the prediction model. The impact of each imaging strategy upon accuracy and reproducibility was quantified. Results: When establishing the predictive model using pre-treatment imaging, four of five patients exhibited poor interfractional reproducibility for either surrogate in subsequent sessions. Simulating the formulation of the predictive model prior to each fraction resulted in improved interfractional reproducibility. The accuracy of the prediction model was only improved in one of five patients when intrafractional imaging was used. Conclusions: Employing a prediction model established from measurements acquired at planning resulted in localization errors. Pre-fractional imaging improved the accuracy and reproducibility of the prediction model. Intrafractional imaging was of less value, suggesting that the accuracy limit of a surrogate-based prediction model is reached with once-daily imaging

  3. Intrafractional tracking accuracy in infrared marker-based hybrid dynamic tumour-tracking irradiation with a gimballed linac

    International Nuclear Information System (INIS)

    Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Yamada, Masahiro; Takahashi, Kunio; Tanabe, Hiroaki; Yano, Shinsuke; Miyabe, Yuki; Ueki, Nami; Kaneko, Shuji; Matsuo, Yukinori; Mizowaki, Takashi; Sawada, Akira; Kokubo, Masaki; Hiraoka, Masahiro

    2014-01-01

    Purpose: To verify the intrafractional tracking accuracy in infrared (IR) marker-based hybrid dynamic tumour tracking irradiation (“IR Tracking”) with the Vero4DRT. Materials and methods: The gimballed X-ray head tracks a moving target by predicting its future position from displacements of IR markers in real-time. Ten lung cancer patients who underwent IR Tracking were enrolled. The 95th percentiles of intrafractional mechanical (iE M 95 ), prediction (iE P 95 ), and overall targeting errors (iE T 95 ) were calculated from orthogonal fluoroscopy images acquired during tracking irradiation and from the synchronously acquired log files. Results: Averaged intrafractional errors were (left–right, cranio-caudal [CC], anterior–posterior [AP]) = (0.1 mm, 0.4 mm, 0.1 mm) for iE M 95 , (1.2 mm, 2.7 mm, 2.1 mm) for iE P 95 , and (1.3 mm, 2.4 mm, 1.4 mm) for iE T 95 . By correcting systematic prediction errors in the previous field, the iE P 95 was reduced significantly, by an average of 0.4 mm in the CC (p < 0.05) and by 0.3 mm in the AP (p < 0.01) directions. Conclusions: Prediction errors were the primary cause of overall targeting errors, whereas mechanical errors were negligible. Furthermore, improvement of the prediction accuracy could be achieved by correcting systematic prediction errors in the previous field

  4. Vacuum immobilisation reduces tumour excursion and minimises intrafraction error in a cohort study of stereotactic ablative body radiotherapy for pulmonary metastases

    International Nuclear Information System (INIS)

    Siva, Shankar; Devereux, Tomas; Kron, Tomas

    2014-01-01

    The purpose of this study is to assess the impact of a vacuum immobilisation system on reproducibility of patient set-up, interfraction stability and tumour motion amplitude. From February 2010 to February 2012 as part of a prospective clinical trial 12 patients with solitary pulmonary metastases had consecutive four-dimensional computed tomography (4DCT) scans performed with and without vacuum immobilisation. The displacement of the tumour centroid position was recorded in each of the 10 phases of the 4DCT reconstruction. A further six patients with seven metastases underwent single fraction stereotactic ablative body radiotherapy (SABR) during this period (a total of 19 targets) and were included in an analysis of positional reproducibility and intrafraction immobilisation. Couch shifts recorded in the medio-lateral (X), cranio-caudal (Y) and ventero-dorsal (Z) planes. For the 19 treatments delivered, the median (0–90% range) shift required immediately pretreatment was 1mm (0–3) in the X-plane, 2mm (0–6) in the Y-plane and 4mm (0–8) in the Z-plane, respectively. The mean (+/− standard deviation) of mid-treatment shifts were 0.3mm (+/− 0.7), 1.1mm (+/− 2) and 0.8mm (+/− 1.5) in the X, Y and Z planes, respectively. Mid-treatment shifts were <2mm in all directions (P=<0.001). The length of treatment time correlated to the required shifts in the Z plane (r2=0.377, P=0.005), but not in the X or Y planes (P=0.198 and P=0.653, respectively). In the subset of 12 patients who had two 4DCTs, the median (range) amplitude of tumour displacements in the X, Y and Z planes when immobilised were 0.9mm (0.3–2.9), 2.6mm (0.2–10.6) and 1.6mm (0.5–5.5), respectively. Immobilisation reduced the volume of tumour displacement during respiration by a median of 52.6% (P=0.021). Vacuum immobilisation reduces total tumour excursion, facilitates reproducible positioning and provides robust intrafractional immobilisation during SABR treatments for pulmonary metastases.

  5. Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position

    International Nuclear Information System (INIS)

    Hugo, Geoffrey D; Di Yan; Jian Liang

    2007-01-01

    In this work, five 4D image-guidance strategies (two population, an offline adaptive and two online strategies) were evaluated that compensated for both inter- and intra-fraction variability such as changes to the baseline tumour position and respiratory pattern. None of the strategies required active motion compensation such as gating or tracking; all strategies simulated a free-breathing-based treatment technique. Online kilovoltage fluoroscopy was acquired for eight patients with lung tumours, and used to construct inter- and intra-fraction tumour position variability models. Planning was performed on a mid-ventilation image acquired from a respiration-correlated CT scan. The blurring effect of tumour position variability was included in the dose calculation by convolution. CTV to PTV margins were calculated for variability in the cranio-caudal direction. A population margin of 9.0 ± 0.7 mm was required to account for setup error and respiration in the study population without the use of image-guidance. The greatest mean margin reduction was introduced by the offline adaptive strategy. A daily online correction strategy produced a small reduction (1.6 mm) in the mean margin from the offline strategy. Adaptively correcting for an inter-fraction change in the respiratory pattern had little effect on margin size due to most patients having only small daily changes in the respiratory pattern. A daily online correction strategy would be useful for patients who exhibit large variations in the daily mean tumour position, while an offline adaptive strategy is more applicable to patients with less variation

  6. Inter- and Intrafraction Variability in Liver Position in Non-Breath-Hold Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Case, Robert B.; Sonke, Jan-Jakob; Moseley, Douglas J.; Kim, John; Brock, Kristy K.; Dawson, Laura A.

    2009-01-01

    Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for unresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility (σ, n = 29 fractions) was 1.3 mm in the ML, 1.4 mm in the CC, and 1.6 mm in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction

  7. A Prospective Study of Intrafraction Prostate Motion in the Prone vs. Supine Position

    International Nuclear Information System (INIS)

    Wilder, Richard B.; Chittenden, Lucy; Mesa, Albert V.; Bunyapanasarn, Jane; Agustin, Jeff; Lizarde, Jessica; Ravera, John; Tokita, Kenneth M.

    2010-01-01

    Purpose: To prospectively analyze prostate intrafraction motion in the prone vs. supine position and to assess patient satisfaction with these two positions. Methods and Materials: Fifteen prostate cancer patients underwent implantation of five fiducial gold seeds in their prostate for localization. Patients were treated with high-dose-rate brachytherapy to 2,200 cGy followed by intensity-modulated radiation therapy (IMRT) to 5,040 cGy. Patients underwent computed tomography simulation and IMRT in the prone position. For the first five IMRT treatments, an electronic portal imaging system was used to acquire anteroposterior (AP) and lateral images pretreatment and posttreatment. We then repositioned each patient supine and repeated the process, resulting in 600 images. Results: Mean ± standard deviation intrafraction prostate motion was 2.1 ± 1.2 mm and 1.7 ± 1.4 mm (AP, p = 0.47), 2.2 ± 2.0 mm and 1.6 ± 1.8 mm (superoinferior, p = 0.16), and 1.0 ± 1.2 mm and 0.6 ± 0.9 mm (left-right, p = 0.03) in the prone and supine positions, respectively. Eighty percent of patients stated that they were more comfortable in the supine position (p = 0.02). Conclusions: Prone and supine positions resulted in a similar magnitude of AP and superoinferior intrafraction prostate motion (2 mm). Because there was no significant difference in the magnitude of AP and superoinferior prostate motion prone vs. supine and patients were more comfortable in the supine position, patients now undergo IMRT to the prostate and seminal vesicles at our center in the supine position.

  8. Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy.

    Science.gov (United States)

    Hirata, Kimiko; Yoshimura, Michio; Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Inoue, Minoru; Sasaki, Makoto; Fujimoto, Takahiro; Yano, Shinsuke; Nakata, Manabu; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-07-01

    We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5mm in all directions. A systematic baseline drift of 1.5mm towards the posterior direction and a random baseline drift of 0.3mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5mm in patients with greater fat thickness due to the baseline drift. The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Josipovic, Mirjana; Fredberg Persson, Gitte; Logadottir, Aashildur; Smulders, Bob; Westmann, Gunnar; Bangsgaard, Jens Peter

    2012-01-01

    Background. Implementation of cone beam computed tomography (CBCT) in frameless stereotactic body radiotherapy (SBRT) of lung tumours enables setup correction based on tumour position. The aim of this study was to compare setup accuracy with daily soft tissue matching to bony anatomy matching and evaluate intra- and inter-fractional translational and rotational errors in patient and target positions. Material and methods. Fifteen consecutive SBRT patients were included in the study. Vacuum cushions were used for immobilisation. SBRT plans were based on midventilation phase of four-dimensional (4D)-CT or three-dimensional (3D)-CT from PET/CT. Margins of 5 mm in the transversal plane and 10 mm in the cranio-caudal (CC) direction were applied. SBRT was delivered in three fractions within a week. At each fraction, CBCT was performed before and after the treatment. Setup accuracy comparison between soft tissue matching and bony anatomy matching was evaluated on pretreatment CBCTs. From differences in pre- and post-treatment CBCTs, we evaluated the extent of translational and rotational intra-fractional changes in patient position, tumour position and tumour baseline shift. All image registration was rigid with six degrees of freedom. Results. The median 3D difference between patient position based on bony anatomy matching and soft tissue matching was 3.0 mm (0-8.3 mm). The median 3D intra-fractional change in patient position was 1.4 mm (0-12.2 mm) and 2.2 mm (0-13.2 mm) in tumour position. The median 3D intra-fractional baseline shift was 2.2 mm (0-4.7 mm). With correction of translational errors, the remaining systematic and random errors were approximately 1deg. Conclusion. Soft tissue tumour matching improved precision of treatment delivery in frameless SBRT of lung tumours compared to image guidance using bone matching. The intra-fractional displacement of the target position was affected by both translational and rotational changes in tumour baseline position

  10. Poster - 46: Intra-fraction tumor position assessment for lung SBRT in patients treated without customized immobilization devices

    International Nuclear Information System (INIS)

    Alamri, Iqbal; Faria, Sergio; Gluszko, Jessica; Patrocinio, Horacio

    2016-01-01

    Purpose: To assess intra-fraction positional stability of lung cancer tumours in patients treated by kilo-voltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) without the use of customized immobilization devices. Material and Methods: Twenty-two patients underwent 4D-CT in the supine position with the arms in a wing board but without customized immobilization. The PTV was the internal target volume based on maximum intensity projections and a 5mm symmetric setup margin. Treatments were planned using 7–9 static fields or two volumetric modulated arcs. At treatment, the patient position was adjusted using pre-treatment CBCT. A post-treatment CBCT was taken immediately after the treatment ended. The 41 CBCT pairs were automatically matched and the transitional shifts between the two CBCTs recorded. The mean values and standard deviations were calculated for these displacements. Results and conclusions: The mean time between CBCTs (treatment time) was 16.5 ± 6 minutes (range: 10 to 34 minutes). In all cases the tumour remained inside the PTV in the post-treatment CBCT. The mean shifts between pre and post-treatment CBCTs were −0.7 ± 1.6 mm (range −5.0 to 3.0 mm) vertically, −0.3 ± 1.7 mm (range −4.8 to 3.0 mm) longitudinally, and −0.4 ± 1.5 mm (range −4.0 to 2.0 mm) laterally. Our results suggest little systematic shifting during treatment, and standard deviations that are consistent with another published report for treatments where customized immobilization was used. This result is encouraging for SBRT programs in clinics with limited resources.

  11. Poster - 46: Intra-fraction tumor position assessment for lung SBRT in patients treated without customized immobilization devices

    Energy Technology Data Exchange (ETDEWEB)

    Alamri, Iqbal; Faria, Sergio; Gluszko, Jessica; Patrocinio, Horacio [McGill University Health Centre (Canada)

    2016-08-15

    Purpose: To assess intra-fraction positional stability of lung cancer tumours in patients treated by kilo-voltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) without the use of customized immobilization devices. Material and Methods: Twenty-two patients underwent 4D-CT in the supine position with the arms in a wing board but without customized immobilization. The PTV was the internal target volume based on maximum intensity projections and a 5mm symmetric setup margin. Treatments were planned using 7–9 static fields or two volumetric modulated arcs. At treatment, the patient position was adjusted using pre-treatment CBCT. A post-treatment CBCT was taken immediately after the treatment ended. The 41 CBCT pairs were automatically matched and the transitional shifts between the two CBCTs recorded. The mean values and standard deviations were calculated for these displacements. Results and conclusions: The mean time between CBCTs (treatment time) was 16.5 ± 6 minutes (range: 10 to 34 minutes). In all cases the tumour remained inside the PTV in the post-treatment CBCT. The mean shifts between pre and post-treatment CBCTs were −0.7 ± 1.6 mm (range −5.0 to 3.0 mm) vertically, −0.3 ± 1.7 mm (range −4.8 to 3.0 mm) longitudinally, and −0.4 ± 1.5 mm (range −4.0 to 2.0 mm) laterally. Our results suggest little systematic shifting during treatment, and standard deviations that are consistent with another published report for treatments where customized immobilization was used. This result is encouraging for SBRT programs in clinics with limited resources.

  12. Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

    International Nuclear Information System (INIS)

    Mutanga, Theodore F.; Boer, Hans C. J. de; Rajan, Vinayakrishnan; Dirkx, Maarten L. P.; Os, Marjolein J. H. van; Incrocci, Luca; Heijmen, Ben J. M.

    2012-01-01

    Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic (Σ) and random (σ) displacements relative to the planning CT measured directly after initial SGT setup correction were eff eff eff eff eff eff < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

  13. Intra-fractional bladder motion and margins in adaptive radiotherapy for urinary bladder cancer

    DEFF Research Database (Denmark)

    Grønborg, Caroline; Vestergaard, Anne; Høyer, Morten

    2015-01-01

    and to estimate population-based and patient-specific intra-fractional margins, also relevant for a future re-optimisation strategy. MATERIAL AND METHODS: Nine patients treated in a clinical phase II ART trial of daily plan selection for bladder cancer were included. In the library plans, 5 mm isotropic margins......BACKGROUND: The bladder is a tumour site well suited for adaptive radiotherapy (ART) due to large inter-fractional changes, but it also displays considerable intra-fractional motion. The aim of this study was to assess target coverage with a clinically applied method for plan selection ART...... were added to account for intra-fractional changes. Pre-treatment and weekly repeat magnetic resonance imaging (MRI) series were acquired in which a full three-dimensional (3D) volume was scanned every second min for 10 min (a total of 366 scans in 61 series). Initially, the bladder clinical target...

  14. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    International Nuclear Information System (INIS)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias

    2008-01-01

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R 2 = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R 2 = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  15. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology

    2008-12-15

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R{sup 2} = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R{sup 2} = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  16. Electromagnetic Tracking of Intrafraction Prostate Displacement in Patients Externally Immobilized in the Prone Position

    International Nuclear Information System (INIS)

    Bittner, Nathan; Butler, Wayne M.; Reed, Joshua L.; Murray, Brian C.; Kurko, Brian S.; Wallner, Kent E.; Merrick, Gregory S.

    2010-01-01

    Purpose: To evaluate intrafraction prostate displacement among patients immobilized in the prone position using real-time monitoring of implanted radiofrequency transponders. Methods and Materials: The Calypso localization system was used to track prostate motion in patients receiving external beam radiation therapy (XRT) for prostate cancer. All patients were treated in the prone position and immobilized with a thermoplastic immobilization device. Real-time measurement of prostate displacement was recorded for each treatment fraction. These measurements were used to determine the duration and magnitude of displacement along the three directional axes. Results: The calculated centroid of the implanted transponders was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 38.0%, 13.9%, and 4.5% of the time. In the lateral dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 2.7%, 0.4%, and 0.06% of the time. In the superior-inferior dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 16.1%, 4.7%, and 1.5% of the time, respectively. In the anterior-posterior dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 13.4%, 3.0%, and 0.5% of the time. Conclusions: Intrafraction prostate displacement in the prone position is comparable to that in the supine position. For patients with large girth, in whom the supine position may preclude accurate detection of implanted radiofrequency transponders, treatment in the prone position is a suitable alternative.

  17. Intra-fraction motion of the prostate is a random walk

    Science.gov (United States)

    Ballhausen, H.; Li, M.; Hegemann, N.-S.; Ganswindt, U.; Belka, C.

    2015-01-01

    A random walk model for intra-fraction motion has been proposed, where at each step the prostate moves a small amount from its current position in a random direction. Online tracking data from perineal ultrasound is used to validate or reject this model against alternatives. Intra-fraction motion of a prostate was recorded by 4D ultrasound (Elekta Clarity system) during 84 fractions of external beam radiotherapy of six patients. In total, the center of the prostate was tracked for 8 h in intervals of 4 s. Maximum likelihood model parameters were fitted to the data. The null hypothesis of a random walk was tested with the Dickey-Fuller test. The null hypothesis of stationarity was tested by the Kwiatkowski-Phillips-Schmidt-Shin test. The increase of variance in prostate position over time and the variability in motility between fractions were analyzed. Intra-fraction motion of the prostate was best described as a stochastic process with an auto-correlation coefficient of ρ = 0.92  ±  0.13. The random walk hypothesis (ρ = 1) could not be rejected (p = 0.27). The static noise hypothesis (ρ = 0) was rejected (p test rejected the null hypothesis ρ = 1 in 25% to 32% of cases. On average, the Kwiatkowski-Phillips-Schmidt-Shin test rejected the null hypothesis ρ = 0 with a probability of 93% to 96%. The variance in prostate position increased linearly over time (r2 = 0.9  ±  0.1). Variance kept increasing and did not settle at a maximum as would be expected from a stationary process. There was substantial variability in motility between fractions and patients with maximum aberrations from isocenter ranging from 0.5 mm to over 10 mm in one patient alone. In conclusion, evidence strongly suggests that intra-fraction motion of the prostate is a random walk and neither static (like inter-fraction setup errors) nor stationary (like a cyclic motion such as breathing, for example). The prostate tends to drift away from the isocenter during a fraction, and

  18. Intra-fraction motion of the prostate is a random walk

    International Nuclear Information System (INIS)

    Ballhausen, H; Li, M; Hegemann, N-S; Ganswindt, U; Belka, C

    2015-01-01

    A random walk model for intra-fraction motion has been proposed, where at each step the prostate moves a small amount from its current position in a random direction. Online tracking data from perineal ultrasound is used to validate or reject this model against alternatives. Intra-fraction motion of a prostate was recorded by 4D ultrasound (Elekta Clarity system) during 84 fractions of external beam radiotherapy of six patients. In total, the center of the prostate was tracked for 8 h in intervals of 4 s. Maximum likelihood model parameters were fitted to the data. The null hypothesis of a random walk was tested with the Dickey–Fuller test. The null hypothesis of stationarity was tested by the Kwiatkowski–Phillips–Schmidt–Shin test. The increase of variance in prostate position over time and the variability in motility between fractions were analyzed. Intra-fraction motion of the prostate was best described as a stochastic process with an auto-correlation coefficient of ρ = 0.92  ±  0.13. The random walk hypothesis (ρ = 1) could not be rejected (p = 0.27). The static noise hypothesis (ρ = 0) was rejected (p < 0.001). The Dickey–Fuller test rejected the null hypothesis ρ = 1 in 25% to 32% of cases. On average, the Kwiatkowski–Phillips–Schmidt–Shin test rejected the null hypothesis ρ = 0 with a probability of 93% to 96%. The variance in prostate position increased linearly over time (r 2 = 0.9  ±  0.1). Variance kept increasing and did not settle at a maximum as would be expected from a stationary process. There was substantial variability in motility between fractions and patients with maximum aberrations from isocenter ranging from 0.5 mm to over 10 mm in one patient alone. In conclusion, evidence strongly suggests that intra-fraction motion of the prostate is a random walk and neither static (like inter-fraction setup errors) nor stationary (like a cyclic motion such as breathing, for example). The prostate tends to

  19. Gene transfer preferentially selects MHC class I positive tumour cells and enhances tumour immunogenicity.

    Science.gov (United States)

    Hacker, Ulrich T; Schildhauer, Ines; Barroso, Margarita Céspedes; Kofler, David M; Gerner, Franz M; Mysliwietz, Josef; Buening, Hildegard; Hallek, Michael; King, Susan B S

    2006-05-01

    The modulated expression of MHC class I on tumour tissue is well documented. Although the effect of MHC class I expression on the tumorigenicity and immunogenicity of MHC class I negative tumour cell lines has been rigorously studied, less is known about the validity of gene transfer and selection in cell lines with a mixed MHC class I phenotype. To address this issue we identified a C26 cell subline that consists of distinct populations of MHC class I (H-2D/K) positive and negative cells. Transient transfection experiments using liposome-based transfer showed a lower transgene expression in MHC class I negative cells. In addition, MHC class I negative cells were more sensitive to antibiotic selection. This led to the generation of fully MHC class I positive cell lines. In contrast to C26 cells, all transfectants were rejected in vivo and induced protection against the parental tumour cells in rechallenge experiments. Tumour cell specificity of the immune response was demonstrated in in vitro cytokine secretion and cytotoxicity assays. Transfectants expressing CD40 ligand and hygromycin phosphotransferase were not more immunogenic than cells expressing hygromycin resistance alone. We suggest that the MHC class I positive phenotype of the C26 transfectants had a bearing on their immunogenicity, because selected MHC class I positive cells were more immunogenic than parental C26 cells and could induce specific anti-tumour immune responses. These data demonstrate that the generation of tumour cell transfectants can lead to the selection of subpopulations that show an altered phenotype compared to the parental cell line and display altered immunogenicity independent of selection marker genes or other immune modulatory genes. Our results show the importance of monitoring gene transfer in the whole tumour cell population, especially for the evaluation of in vivo therapies targeted to heterogeneous tumour cell populations.

  20. Stereotactic radiotherapy using tomotherapy for early-stage non-small cell lung carcinoma: analysis of intrafaction tumour motion

    International Nuclear Information System (INIS)

    Boggs, Drexell Hunter; Feigenberg, Steven; Walter, Robert; Wissing, Dennis; Patel, Bijal; Wu, Terry; Rosen, Lane

    2014-01-01

    Intrafraction tumour motion in helical tomotherapy was investigated by comparing pre- and mid-fraction CT scans in patients with early non-small cell lung carcinoma (NSCLC) to assess the efficacy of a 7-mm margin around gross tumour volumes (GTVs) in stereotactic body radiation therapy (SBRT). Thirty patients with early-stage NSCLC received SBRT in four or five fractions for a total of 141 treatments. A slow positron emission tomography/CT scan was fused with the simulation CT to determine the GTV. A planning target volume was created by placing an isotropic margin of 7mm around the GTV. Data were retrospectively analyzed to assess translational tumour positional changes along the x, y and z axes and vector changes in millimeters from the pretreatment megavoltage (MV)-CT to the mid-fraction MV-CT. Average movements for all 141 treatment days along the x, y and z axes were 0.5±2.3, −0.3±3.0 and 0.9±3.0mm, respectively. Average movements for each patient along the x, y and z axes were 0.5±1.5, −0.2±2.0 and 0.9±1.9mm, respectively. Average vector displacement was 4.3±2.4mm for all treatment days and 4.2±1.7mm for each patient. Of 141 treatments, 137 (97.2%) fell within 7.0mm in all axes. The addition of a 7-mm margin to the GTV for patients receiving SBRT for NSCLC using tomotherapy is adequate to account for tumour movement. Mid-fraction CT scans proved to be valuable in assessing intrafraction tumour motion.

  1. Influence of Antiflatulent Dietary Advice on Intrafraction Motion for Prostate Cancer Radiotherapy

    International Nuclear Information System (INIS)

    Lips, Irene M.; Kotte, Alexis N.T.J.; Gils, Carla H. van; Leerdam, Monique E. van; Heide, Uulke A. van der; Vulpen, Marco van

    2011-01-01

    Purpose: To evaluate the effect of an antiflatulent dietary advice on the intrafraction prostate motion in patients treated with intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Between February 2002 and December 2009, 977 patients received five-beam IMRT for prostate cancer to a dose of 76 Gy in 35 fractions combined with fiducial markers for position verification. In July 2008, the diet, consisting of dietary guidelines to obtain regular bowel movements and to reduce intestinal gas by avoiding certain foods and air swallowing, was introduced to reduce the prostate motion. The intrafraction prostate movement was determined from the portal images of the first segment of all five beams. Clinically relevant intrafraction motion was defined as ≥50% of the fractions with an intrafraction motion outside a range of 3 mm. Results: A total of 739 patients were treated without the diet and 105 patients were treated with radiotherapy after introduction of the diet. The median and interquartile range of the average intrafraction motion per patient was 2.53 mm (interquartile range, 2.2–3.0) without the diet and 3.00 mm (interquartile range, 2.4–3.5) with the diet (p < .0001). The percentage of patients with clinically relevant intrafraction motion increased statistically significant from 19.1% without diet to 42.9% with a diet (odds ratio, 3.18; 95% confidence interval, 2.07–4.88; p < .0001). Conclusions: The results of the present study suggest that antiflatulent dietary advice for patients undergoing IMRT for prostate cancer does not reduce the intrafraction movement of the prostate. Therefore, antiflatulent dietary advice is not recommended in clinical practice for this purpose.

  2. Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

    International Nuclear Information System (INIS)

    Tryggestad, Erik; Christian, Matthew; Ford, Eric; Kut, Carmen; Le Yi; Sanguineti, Giuseppe; Song, Danny Y.; Kleinberg, Lawrence

    2011-01-01

    Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts (± SD) were 2.3 (± 1.4), 2.2 (± 1.1), 2.7 (± 1.5), and 2.1 (± 1.0) mm whereas intrafraction motion was 1.1 (± 1.2), 1.1 (± 1.1), 0.7 (± 0.9), and 0.7 (± 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

  3. Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT.

    Science.gov (United States)

    Tryggestad, Erik; Christian, Matthew; Ford, Eric; Kut, Carmen; Le, Yi; Sanguineti, Giuseppe; Song, Danny Y; Kleinberg, Lawrence

    2011-05-01

    To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts (± SD) were 2.3 (± 1.4), 2.2 (± 1.1), 2.7 (± 1.5), and 2.1 (± 1.0) mm whereas intrafraction motion was 1.1 (± 1.2), 1.1 (± 1.1), 0.7 (± 0.9), and 0.7 (± 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic Imaging

    International Nuclear Information System (INIS)

    Hoogeman, Mischa S.; Nuyttens, Joost J.; Levendag, Peter C.; Heijmen, Ben J.M.

    2008-01-01

    Purpose: To quantify intrafraction patient motion and its time dependence in immobilized intracranial and extracranial patients. The data can be used to optimize the intrafraction imaging frequency and consequent patient setup correction with an image guidance and tracking system, and to establish the required safety margins in the absence of such a system. Method and Materials: The intrafraction motion of 32 intracranial patients, immobilized with a thermoplastic mask, and 11 supine- and 14 prone-treated extracranial spine patients, immobilized with a vacuum bag, were analyzed. The motion was recorded by an X-ray, stereoscopic, image-guidance system. For each group, we calculated separately the systematic (overall mean and SD) and the random displacement as a function of elapsed intrafraction time. Results: The SD of the systematic intrafraction displacements increased linearly over time for all three patient groups. For intracranial-, supine-, and prone-treated patients, the SD increased to 0.8, 1.2, and 2.2 mm, respectively, in a period of 15 min. The random displacements for the prone-treated patients were significantly higher than for the other groups, namely 1.6 mm (1 SD), probably caused by respiratory motion. Conclusions: Despite the applied immobilization devices, patients drift away from their initial position during a treatment fraction. These drifts are in general small if compared with conventional treatment margins, but will significantly contribute to the margin for high-precision radiation treatments with treatment times of 15 min or longer

  5. Effect of immobilization and performance status on intrafraction motion for stereotactic lung radiotherapy: analysis of 133 patients.

    Science.gov (United States)

    Li, Winnie; Purdie, Thomas G; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B C John; Hope, Andrew; Sun, Alexander; Jaffray, David A; Bezjak, Andrea; Bissonnette, Jean-Pierre

    2011-12-01

    To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n=75], evacuated cushion plus abdominal compression [n=33], or chest board [n=25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n=31), 1 (n=70), or 2 (n=32). Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (pPositional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p=0.04). Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as

  6. Effect of Immobilization and Performance Status on Intrafraction Motion for Stereotactic Lung Radiotherapy: Analysis of 133 Patients

    International Nuclear Information System (INIS)

    Li, Winnie; Purdie, Thomas G.; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B.C. John; Hope, Andrew; Sun, Alexander; Jaffray, David A.; Bezjak, Andrea; Bissonnette, Jean-Pierre

    2011-01-01

    Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board–approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients’ Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial–caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization

  7. Intrafractional prostate motion during online image guided intensity-modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Budiharto, Tom; Slagmolen, Pieter; Haustermans, Karin; Maes, Frederik; Junius, Sara; Verstraete, Jan; Oyen, Raymond; Hermans, Jeroen; Van den Heuvel, Frank

    2011-01-01

    Introduction: Intrafractional motion consists of two components: (1) the movement between the on-line repositioning procedure and the treatment start and (2) the movement during the treatment delivery. The goal of this study is to estimate this intrafractional movement of the prostate during prostate cancer radiotherapy. Material and methods: Twenty-seven patients with prostate cancer and implanted fiducials underwent a marker match procedure before a five-field IMRT treatment. For all fields, in-treatment images were obtained and then processed to enable automatic marker detection. Combining the subsequent projection images, five positions of each marker were determined using the shortest path approach. The residual set-up error (RSE) after kV-MV based prostate localization, the prostate position as a function of time during a radiotherapy session and the required margins to account for intrafractional motion were determined. Results: The mean RSE and standard deviation in the antero-posterior, cranio-caudal and left-right direction were 2.3 ± 1.5 mm, 0.2 ± 1.1 mm and -0.1 ± 1.1 mm, respectively. Almost all motions occurred in the posterior direction before the first treatment beam as the percentage of excursions >5 mm was reduced significantly when the RSE was not accounted for. The required margins for intrafractional motion increased with prolongation of the treatment. Application of a repositioning protocol after every beam could decrease the 1 cm margin from CTV to PTV by 2 mm. Conclusions: The RSE is the main contributor to intrafractional motion. This RSE after on-line prostate localization and patient repositioning in the posterior direction emphasizes the need to speed up the marker match procedure. Also, a prostate IMRT treatment should be administered as fast as possible, to ensure that the pre-treatment repositioning efforts are not erased by intrafractional prostate motion. This warrants an optimized workflow with the use of faster treatment

  8. Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy : Comparison of gold marker-based registrations with native MVCT.

    Science.gov (United States)

    Wust, Peter; Joswig, Marc; Graf, Reinhold; Böhmer, Dirk; Beck, Marcus; Barelkowski, Thomasz; Budach, Volker; Ghadjar, Pirus

    2017-09-01

    For high-dose radiation therapy (RT) of prostate cancer, image-guided (IGRT) and intensity-modulated RT (IMRT) approaches are standard. Less is known regarding comparisons of different IGRT techniques and the resulting residual errors, as well as regarding their influences on dose distributions. A total of 58 patients who received tomotherapy-based RT up to 84 Gy for high-risk prostate cancer underwent IGRT based either on daily megavoltage CT (MVCT) alone (n = 43) or the additional use of gold markers (n = 15) under routine conditions. Planned Adaptive (Accuray Inc., Madison, WI, USA) software was used for elaborated offline analysis to quantify residual interfractional prostate positioning errors, along with systematic and random errors and the resulting safety margins after both IGRT approaches. Dosimetric parameters for clinical target volume (CTV) coverage and exposition of organs at risk (OAR) were also analyzed and compared. Interfractional as well as intrafractional displacements were determined. Particularly in the vertical direction, residual interfractional positioning errors were reduced using the gold marker-based approach, but dosimetric differences were moderate and the clinical relevance relatively small. Intrafractional prostate motion proved to be quite high, with displacements of 1-3 mm; however, these did not result in additional dosimetric impairments. Residual interfractional positioning errors were reduced using gold marker-based IGRT; however, this resulted in only slightly different final dose distributions. Therefore, daily MVCT-based IGRT without markers might be a valid alternative.

  9. SU-E-J-133: Evaluation of Inter- and Intra-Fractional Pancreas Tumor Residual Motions with Abdominal Compression

    International Nuclear Information System (INIS)

    Li, Y; Shi, F; Tian, Z; Jia, X; Meyer, J; Jiang, S; Mao, W

    2014-01-01

    Purpose: Abdominal compression (AC) has been widely used to reduce pancreas motion due to respiration for pancreatic cancer patients undergoing stereotactic body radiotherapy (SBRT). However, the inter-fractional and intra-fractional patient motions may degrade the treatment. The purpose of this work is to study daily CBCT projections and 4DCT to evaluate the inter-fractional and intra-fractional pancreatic motions. Methods: As a standard of care at our institution, 4D CT scan was performed for treatment planning. At least two CBCT scans were performed for daily treatment. Retrospective studies were performed on patients with implanted internal fiducial markers or surgical clips. The initial motion pattern was obtained by extracting marker positions on every phase of 4D CT images. Daily motions were presented by marker positions on CBCT scan projection images. An adaptive threshold segmentation algorithm was used to extract maker positions. Both marker average positions and motion ranges were compared among three sets of scans, 4D CT, positioning CBCT, and conformal CBCT, for inter-fractional and intra-fractional motion variations. Results: Data from four pancreatic cancer patients were analyzed. These patients had three fiducial markers implanted. All patients were treated by an Elekta Synergy with single fraction SBRT. CBCT projections were acquired by XVI. Markers were successfully detected on most of the projection images. The inter-fractional changes were determined by 4D CT and the first CBCT while the intra-fractional changes were determined by multiple CBCT scans. It is found that the average motion range variations are within 2 mm, however, the average marker positions may drift by 6.5 mm. Conclusion: The patients respiratory motion variation for pancreas SBRT with AC was evaluated by detecting markers from CBCT projections and 4DCT, both the inter-fraction and intra-fraction motion range change is small but the drift of marker positions may be comparable

  10. Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruijiang; Han, Bin; Meng, Bowen [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G.; Xing, Lei; Koong, Albert C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2013-12-01

    Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide

  11. Reduction of prostate intrafraction motion using gas-release rectal balloons

    International Nuclear Information System (INIS)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy

    2012-01-01

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5Σ+ 0.7σ to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior–inferior (SI) and anterior–posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left–right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  12. Reduction of prostate intrafraction motion using gas-release rectal balloons

    Energy Technology Data Exchange (ETDEWEB)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy [Department of Radiation Oncology, University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States)

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  13. Measurement of intrafractional prostate motion using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mah, Dennis; Freedman, Gary; Milestone, Bart; Hanlon, Alexandra; Palacio, Elizabeth; Richardson, Theresa; Movsas, Benjamin; Mitra, Raj; Horwitz, Eric; Hanks, Gerald E.

    2002-01-01

    Purpose: To quantify the three-dimensional intrafractional prostate motion over typical treatment time intervals with cine-magnetic resonance imaging (cine MRI) studies. Methods and Materials: Forty-two patients with prostate cancer were scanned supine in an alpha cradle cast using cine MRI. Twenty sequential slices were acquired in the sagittal and axial planes through the center of the prostate. Each scan took ∼9 min. The posterior, lateral, and superior edges of the prostate were tracked on each frame relative to the initial prostate position, and the size and duration of each displacement was recorded. Results: The prostate displacements were (mean ± SD): 0.2 ± 2.9 mm, 0.0 ± 3.4 mm, and 0.0 ± 1.5 mm in the anterior-posterior, superior-inferior, and medial-lateral dimensions respectively. The prostate motion appeared to have been driven by peristalsis in the rectum. Large displacements of the prostate (up to 1.2 cm) moved the prostate both anteriorly and superiorly and in some cases compressed the organ. For such motions, the prostate did not stay displaced, but moved back to its original position. To account for the dosimetric consequences of the motion, we also calculated the time-averaged displacement to be ∼1 mm. Conclusions: Cine MRI can be used to measure intrafractional prostate motion. Although intrafractional prostate motions occur, their effects are negligible compared to interfractional motion and setup error. No adjustment in margin is necessary for three-dimensional conformal or intensity-modulated radiation therapy

  14. Radiopaque marker motion during pre-treatment CBCT as a predictor of intra-fractional prostate movement

    International Nuclear Information System (INIS)

    Bernchou, Uffe; Brink, Carsten; Agergaard, Soeren N.

    2013-01-01

    The intra-fractional movement of the prostate constitutes a hindrance for the reduction of the planning target volume margin for prostate cancer patients. Monitoring the movement of the prostate during treatment is a promising but in most centres not feasible solution. However, the projection images of the pre-treatment cone-beam computed tomography (CBCT) provide information about the motion of the target immediately preceding the treatment. This motion information can be extracted from any standard CBCT scan which is available in many institutions. In this study we measure the motion of the prostate during the pre-treatment CBCT and investigate whether this motion is correlated with the intra-fractional movement of the prostate. Material and methods: Pre- and post-treatment CBCT scans were made during a number of the fractions (average 11 range 8-12) for 13 prostate cancer patients during the radiation treatment course. The displacement of the post-treatment CBCT scans relative to the pre-treatment position was used to assess the intra-fractional motion. Automated image analysis was used to track the 2D position of radiopaque markers in the projection images of the scans. The most probable 3D trajectory of the markers during the CBCT scan was estimated based on a probability density function which was established for each individual scan. Results: The accuracy of the tracking algorithm was found satisfactory and the motion of the markers during the CBCT scans was successfully extracted from the projection images. This motion was generally small and uncorrelated with the subsequent intra-fractional movement of the prostate. The correlation coefficients were - 0.05, 0.07, and - 0.05 in the LR, AP, and CC direction, respectively. Conclusion: It is tempting to exploit the pre-treatment CBCT to predict the intra-fractional movement of the prostate but, unfortunately, we have found no correlation between the intra-fractional movement and the motion of the prostate

  15. Interfraction and intrafraction performance of the Gamma Knife Extend system for patient positioning and immobilization.

    Science.gov (United States)

    Schlesinger, David; Xu, Zhiyuan; Taylor, Frances; Yen, Chun-Po; Sheehan, Jason

    2012-12-01

    The Extend system for the Gamma Knife Perfexion makes possible multifractional Gamma Knife treatments. The Extend system consists of a vacuum-monitored immobilization frame and a positioning measurement system used to determine the location of the patient's head within the frame at the time of simulation imaging and before each treatment fraction. The measurement system consists of a repositioning check tool (RCT), which attaches to the Extend frame, and associated digital measuring gauges. The purpose of this study is to evaluate the performance of the Extend system for patient repositioning before each treatment session (fraction) and patient immobilization between (interfraction) and during (intrafraction) each session in the first 10 patients (36 fractional treatments) treated at the University of Virginia. The RCT was used to acquire a set of reference measurements for each patient position at the time of CT simulation. Repositioning measurements were acquired before each fraction, and the patient position was adjusted until the residual radial difference from the reference position measurements was less than 1 mm. After treatment, patient position measurements were acquired, and the difference between those measurements and the ones obtained for patient position before the fraction was calculated as a measure of immobilization capability. Analysis of patient setup and immobilization performance included calculation of the group mean, standard deviation (SD), and distribution of systematic (components affecting all fractions) and random (per fraction) uncertainty components. Across all patients and fractions, the mean radial setup difference from the reference measurements was 0.64 mm, with an SD of 0.24 mm. The distribution of systematic uncertainty (Σ) was 0.17 mm, and the distribution of random uncertainty (σ) was 0.16 mm. The root mean square (RMS) differences for each plate of the RCT were as follows: right = 0.35 mm; left = 0.41 mm; superior = 0.28 mm

  16. SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Cao, D; Jermoumi, M; Mehta, V; Shepard, D [Swedish Cancer Institute, Seattle, WA (United States)

    2016-06-15

    Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

  17. Intrafraction Bladder Motion in Radiation Therapy Estimated From Pretreatment and Posttreatment Volumetric Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Foroudi, Farshad, E-mail: farshad.foroudi@petermac.org [Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Pham, Daniel [Radiation Therapy Services, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Bressel, Mathias [Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Gill, Suki [Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Kron, Tomas [Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia)

    2013-05-01

    Purpose: The use of image guidance protocols using soft tissue anatomy identification before treatment can reduce interfractional variation. This makes intrafraction clinical target volume (CTV) to planning target volume (PTV) changes more important, including those resulting from intrafraction bladder filling and motion. The purpose of this study was to investigate the required intrafraction margins for soft tissue image guidance from pretreatment and posttreatment volumetric imaging. Methods and Materials: Fifty patients with muscle-invasive bladder cancer (T2-T4) underwent an adaptive radiation therapy protocol using daily pretreatment cone beam computed tomography (CBCT) with weekly posttreatment CBCT. A total of 235 pairs of pretreatment and posttreatment CBCT images were retrospectively contoured by a single radiation oncologist (CBCT-CTV). The maximum bladder displacement was measured according to the patient's bony pelvis movement during treatment, intrafraction bladder filling, and bladder centroid motion. Results: The mean time between pretreatment and posttreatment CBCT was 13 minutes, 52 seconds (range, 7 min 52 sec to 30 min 56 sec). Taking into account patient motion, bladder centroid motion, and bladder filling, the required margins to cover intrafraction changes from pretreatment to posttreatment in the superior, inferior, right, left, anterior, and posterior were 1.25 cm (range, 1.19-1.50 cm), 0.67 cm (range, 0.58-1.12 cm), 0.74 cm (range, 0.59-0.94 cm), 0.73 cm (range, 0.51-1.00 cm), 1.20 cm (range, 0.85-1.32 cm), and 0.86 cm (range, 0.73-0.99), respectively. Small bladders on pretreatment imaging had relatively the largest increase in pretreatment to posttreatment volume. Conclusion: Intrafraction motion of the bladder based on pretreatment and posttreatment bladder imaging can be significant particularly in the anterior and superior directions. Patient motion, bladder centroid motion, and bladder filling all contribute to changes between

  18. SU-E-J-57: First Development of Adapting to Intrafraction Relative Motion Between Prostate and Pelvic Lymph Nodes Targets

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Y; Colvill, E; O’Brien, R; Keall, P [Radiation Physics Laboratory, University of Sydney, NSW (Australia); Booth, J [Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW (Australia)

    2015-06-15

    Purpose Large intrafraction relative motion of multiple targets is common in advanced head and neck, lung, abdominal, gynaecological and urological cancer, jeopardizing the treatment outcomes. The objective of this study is to develop a real-time adaptation strategy, for the first time, to accurately correct for the relative motion of multiple targets by reshaping the treatment field using the multi-leaf collimator (MLC). Methods The principle of tracking the simultaneously treated but differentially moving tumor targets is to determine the new aperture shape that conforms to the shifted targets. Three dimensional volumes representing the individual targets are projected to the beam’s eye view. The leaf openings falling inside each 2D projection will be shifted according to the measured motion of each target to form the new aperture shape. Based on the updated beam shape, new leaf positions will be determined with optimized trade-off between the target underdose and healthy tissue overdose, and considerations of the physical constraints of the MLC. Taking a prostate cancer patient with pelvic lymph node involvement as an example, a preliminary dosimetric study was conducted to demonstrate the potential treatment improvement compared to the state-of- art adaptation technique which shifts the whole beam to track only one target. Results The world-first intrafraction adaptation system capable of reshaping the beam to correct for the relative motion of multiple targets has been developed. The dose in the static nodes and small bowel are closer to the planned distribution and the V45 of small bowel is decreased from 110cc to 75cc, corresponding to a 30% reduction by this technique compared to the state-of-art adaptation technique. Conclusion The developed adaptation system to correct for intrafraction relative motion of multiple targets will guarantee the tumour coverage and thus enable PTV margin reduction to minimize the high target dose to the adjacent organs

  19. Intra-fraction motion of larynx radiotherapy

    Science.gov (United States)

    Durmus, Ismail Faruk; Tas, Bora

    2018-02-01

    In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.

  20. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  1. Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC

    DEFF Research Database (Denmark)

    Jensen, Henrik R; Hansen, Olfred; Hjelm-Hansen, Mogens

    2008-01-01

    where given a stereotactic treatment. The patients were scanned with normal and uncoached respiration without use of abdominal compression. Each patient had CT-scans performed at four occasions throughout the treatment: As part of the CT-simulation and before the three radiotherapy treatments. At every...... frame were LR: 1.5 mm, AP: 1.1 mm and CC: 1.7 mm (1 SD). DISCUSSION AND CONCLUSIONS: Consecutive CT scans can be used to evaluate the respiration induced tumour movement. For patients immobilized in a stereotactic body frame, large movements of the tumour are rarely seen within the lung...

  2. Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Yue, Ning J.; Goyal, Sharad; Zhou Jinghao; Khan, Atif J.; Haffty, Bruce G.

    2011-01-01

    Purpose: This study investigated the magnitude of intrafractional motion and level of accuracy of various setup strategies in accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy. Methods and Materials: At lumpectomy, gold fiducial markers were strategically sutured to the surrounding walls of the cavity. Weekly fluoroscopy imaging was conducted at treatment to investigate the respiration-induced target motions. Daily pre- and post-RT kV imaging was performed, and images were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion magnitudes over the course of treatment. The positioning differences of the laser tattoo- and the bony anatomy-based setups compared with those of the marker-based setup (benchmark) were also determined. The study included 21 patients. Results: Although lung exhibited significant motion, the average marker motion amplitude on the fluoroscopic image was about 1 mm. Over a typical treatment time period, average intrafractional motion magnitude was 4.2 mm and 2.6 mm based on the marker and bony anatomy matching, respectively. The bony anatomy- and laser tattoo-based interfractional setup errors, with respect to the fiducial marker-based setup, were 7.1 and 9.0 mm, respectively. Conclusions: Respiration has limited effects on the target motion during APBI. Bony anatomy-based treatment setup improves the accuracy relative to that of the laser tattoo-based setup approach. Since fiducial markers are sutured directly to the surgical cavity, the marker-based approach can further improve the interfractional setup accuracy. On average, a seroma cavity exhibits intrafractional motion of more than 4 mm, a magnitude that is larger than that which is otherwise derived based on bony anatomy matching. A seroma-specific marker-based approach has the potential to improve treatment accuracy by taking the true inter

  3. Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer

    International Nuclear Information System (INIS)

    Cheung, Patrick; Sixel, Katharina; Morton, Gerard; Loblaw, D. Andrew; Tirona, Romeo; Pang, Geordi; Choo, Richard; Szumacher, Ewa; DeBoer, Gerrit; Pignol, Jean-Philippe

    2005-01-01

    Purpose: The objective of the study was to access toxicities of delivering a hypofractionated intensity-modulated radiotherapy (IMRT) boost with individualized intrafraction planning target volume (PTV) margins and daily online correction for prostate position. Methods and materials: Phase I involved delivering 42 Gy in 21 fractions using three-dimensional conformal radiotherapy, followed by a Phase II IMRT boost of 30 Gy in 10 fractions. Digital fluoroscopy was used to measure respiratory-induced motion of implanted fiducial markers within the prostate. Electronic portal images were taken of fiducial marker positions before and after each fraction of radiotherapy during the first 9 days of treatment to calculate intrafraction motion. A uniform 10-mm PTV margin was used for the first phase of treatment. PTV margins for Phase II were patient-specific and were calculated from the respiratory and intrafraction motion data obtained from Phase I. The IMRT boost was delivered with daily online correction of fiducial marker position. Acute toxicity was measured using National Cancer Institute Common Toxicity Criteria, version 2.0. Results: In 33 patients who had completed treatment, the average PTV margin used during the hypofractionated IMRT boost was 3 mm in the lateral direction, 3 mm in the superior-inferior direction, and 4 mm in the anteroposterior direction. No patients developed acute Grade 3 rectal toxicity. Three patients developed acute Grade 3 urinary frequency and urgency. Conclusions: PTV margins can be reduced significantly with daily online correction of prostate position. Delivering a hypofractionated boost with this high-precision IMRT technique resulted in acceptable acute toxicity

  4. Adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion

    International Nuclear Information System (INIS)

    Webb, S

    2008-01-01

    This paper presents a technique for coping with variable intrafraction organ motion when delivering intensity-modulated radiation therapy (IMRT). The strategy is an adaptive delivery in which the fluence delivered up to a particular fraction is subtracted from the required total-course planned fluence to create an adapted residual fluence for the next fraction. This requires that the fluence already delivered can be computed, knowing the intrafraction motion during each fraction. If the adaptation is unconstrained, as would be required for perfect delivery of the planned fluence, then the individual fractional fluences would become unphysical, with both negative components and spikes. Hence it is argued that constraints must be applied; first, positivity constraints and second, constraints to limit fluence spikes. Additionally, it is shown to be helpful to constrain other quantities which are explained. The power of the strategy is that it adapts to the (potentially variable) moving geometry during each fraction. It is not a perfect delivery but it is always better than making no adaptation. The fractionated nature of radiation therapy is thus exploited to advantage. The fluence adaptation method does not require re-planning at each fraction but this imposes limitations which are stated. The fuller theory of dose adaptation is also developed for intrafraction motion. The method is complementary to other adaptive strategies recently discussed with respect to interfraction motion

  5. Targeting Chromosomal Instability and Tumour Heterogeneity in HER2-Positive Breast Cancer

    DEFF Research Database (Denmark)

    Burrell, Rebecca A.; Birkbak, Nicolai Juul; Johnston, Stephen R.

    2010-01-01

    Chromosomal instability (CIN) is a common cause of tumour heterogeneity and poor prognosis in solid tumours and describes cell-cell variation in chromosome structure or number across a tumour population. In this article we consider evidence suggesting that CIN may be targeted and may influence...... response to distinct chemotherapy regimens, using HER2-positive breast cancer as an example. Pre-clinical models have indicated a role for HER2 signalling in initiating CIN and defective cell-cycle control, and evidence suggests that HER2-targeting may attenuate this process. Anthracyclines and platinum...... agents may target tumours with distinct patterns of karyotypic complexity, whereas taxanes may have preferential activity in tumours with relative chromosomal stability. A greater understanding of karyotypic complexity and identification of methods to directly examine and target CIN may support novel...

  6. Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yorke, Ellen, E-mail: yorke@mskcc.org [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Xiong, Ying [Department of Radiation Oncology, China-Japan Friendship Hospital, Beijing (China); Han, Qian [Department of Radiotherapy, Henan Provincial People' s Hospital, Zhengzhou (China); Zhang, Pengpeng; Mageras, Gikas; Lovelock, Michael; Pham, Hai; Xiong, Jian-Ping [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Goodman, Karyn A. [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2016-07-01

    Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). Methods and Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Results: Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of −1.2% (range, −11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Conclusions: Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable.

  7. Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors

    International Nuclear Information System (INIS)

    Yorke, Ellen; Xiong, Ying; Han, Qian; Zhang, Pengpeng; Mageras, Gikas; Lovelock, Michael; Pham, Hai; Xiong, Jian-Ping; Goodman, Karyn A.

    2016-01-01

    Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). Methods and Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Results: Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of −1.2% (range, −11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Conclusions: Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable.

  8. Tumour 18 F-FDG Uptake on preoperative PET/CT may predict axillary lymph node metastasis in ER-positive/HER2-negative and HER2-positive breast cancer subtypes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin You; Lee, Suck Hong; Kim, Suk [Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Department of Radiology, Seo-gu, Busan (Korea, Republic of); Kang, Taewoo [Pusan National University Hospital, Busan Cancer Center, Busan (Korea, Republic of); Bae, Young Tae [Pusan National University Hospital, Department of Surgery, Busan (Korea, Republic of)

    2015-04-01

    To evaluate the association between tumour FDG uptake on preoperative PET/CT and axillary lymph node metastasis (ALNM) according to breast cancer subtype. The records of 671 patients with invasive breast cancer who underwent {sup 18} F-FDG PET/CT and surgery were reviewed. Using immunohistochemistry, tumours were divided into three subtypes: oestrogen receptor (ER)-positive/human epidermal growth factor receptor 2 (HER2)-negative, HER2-positive, and triple-negative. Tumour FDG uptake, expressed as maximum standardized uptake value (SUV{sub max}), and clinicopathological variables were analysed. ALNM was present in 187 of 461 ER-positive/HER2-negative, 54 of 97 HER2-positive, and 38 of 113 triple-negative tumours. On multivariate analysis, high tumour SUV{sub max} (≥4.25) (P < 0.001), large tumour size (>2 cm) (P = 0.003) and presence of lymphovascular invasion (P < 0.001) were independent variables associated with ALNM. On subset analyses, tumour SUV{sub max} maintained independent significance for predicting ALNM in ER-positive/HER2-negative (adjusted odds ratio: 3.277, P < 0.001) and HER2-positive tumours (adjusted odds ratio: 14.637, P = 0.004). No association was found for triple-negative tumours (P = 0.161). Tumour SUV{sub max} may be an independent prognostic factor for ALNM in patients with invasive breast cancer, especially in ER-positive/HER2-negative and HER2-positive subtypes, but not in those with triple-negative subtype. (orig.)

  9. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy.

    Science.gov (United States)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Joo; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-04-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08-7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT. © 2014 The Royal Australian and New Zealand College of Radiologists.

  10. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Jooh; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-01-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08–7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P < 0.05). The CTV-to-PTV margin necessary to allow for movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT.

  11. Intra-fraction motion of the prostate during treatment with helical tomotherapy

    International Nuclear Information System (INIS)

    Thomas, Simon J.; Ashburner, Mark; Tudor, George Samuel J.; Treeby, Jo; Dean, June; Routsis, Donna; Rimmer, Yvonne L.; Russell, Simon G.; Burnet, Neil G.

    2013-01-01

    Background and purpose: To measure the geometric uncertainty resulting from intra-fraction motion and intra-observer image matching, for patients having image-guided prostate radiotherapy on TomoTherapy. Material and methods: All patients had already been selected for prostate radiotherapy on TomoTherapy, with daily MV-CT imaging. The study involved performing an additional MV-CT image at the end of treatment, on 5 occasions during the course of 37 treatments. 54 patients were recruited to the study. A new formula was derived to calculate the PTV margin for intra-fraction motion. Results: The mean values of the intra-fraction differences were 0.0 mm, 0.5 mm, 0.5 mm and 0.0° for LR, SI, AP and roll, respectively. The corresponding standard deviations were 1.1 mm, 0.8 mm, 0.8 mm and 0.6° for systematic uncertainties (Σ), 1.3 mm, 2.0 mm, 2.2 mm and 0.3° for random uncertainties (σ). This intra-fraction motion requires margins of 2.2 mm in LR, 2.1 mm in SI and 2.1 mm in AP directions. Inclusion of estimates of the effect of rotations and matching errors increases these margins to approximately 4 mm in LR and 5 mm in SI and AP directions. Conclusions: A new margin recipe has been developed to calculate margins for intra-fraction motion. This recipe is applicable to any measurement technique that is based on the difference between images taken before and after treatment

  12. A Double-Blind Placebo-Controlled Randomized Clinical Trial With Magnesium Oxide to Reduce Intrafraction Prostate Motion for Prostate Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lips, Irene M., E-mail: i.m.lips@umcutrecht.nl [Department of Radiation Oncology, University Medical Center Utrecht, Utrecht (Netherlands); Gils, Carla H. van [Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht (Netherlands); Kotte, Alexis N.T.J. [Department of Radiation Oncology, University Medical Center Utrecht, Utrecht (Netherlands); Leerdam, Monique E. van [Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam (Netherlands); Franken, Stefan P.G.; Heide, Uulke A. van der; Vulpen, Marco van [Department of Radiation Oncology, University Medical Center Utrecht, Utrecht (Netherlands)

    2012-06-01

    Purpose: To investigate whether magnesium oxide during external-beam radiotherapy for prostate cancer reduces intrafraction prostate motion in a double-blind, placebo-controlled randomized trial. Methods and Materials: At the Department of Radiotherapy, prostate cancer patients scheduled for intensity-modulated radiotherapy (77 Gy in 35 fractions) using fiducial marker-based position verification were randomly assigned to receive magnesium oxide (500 mg twice a day) or placebo during radiotherapy. The primary outcome was the proportion of patients with clinically relevant intrafraction prostate motion, defined as the proportion of patients who demonstrated in {>=}50% of the fractions an intrafraction motion outside a range of 2 mm. Secondary outcome measures included quality of life and acute toxicity. Results: In total, 46 patients per treatment arm were enrolled. The primary endpoint did not show a statistically significant difference between the treatment arms with a percentage of patients with clinically relevant intrafraction motion of 83% in the magnesium oxide arm as compared with 80% in the placebo arm (p = 1.00). Concerning the secondary endpoints, exploratory analyses demonstrated a trend towards worsened quality of life and slightly more toxicity in the magnesium oxide arm than in the placebo arm; however, these differences were not statistically significant. Conclusions: Magnesium oxide is not effective in reducing the intrafraction prostate motion during external-beam radiotherapy, and therefore there is no indication to use it in clinical practice for this purpose.

  13. Six dimensional analysis with daily stereoscopic x-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks

    International Nuclear Information System (INIS)

    Linthout, Nadine; Verellen, Dirk; Tournel, Koen; Storme, Guy

    2006-01-01

    The safety margins used to define the Planning Target Volume (PTV) should reflect the accuracy of the target localization during treatment that comprises both the reproducibility of the patient positioning and the positional uncertainty of the target, so both the inter- and intrafraction motion of the target. Our first aim in this study was to determine the intrafraction motion of patients immobilized with a five-point thermoplastic mask for head and neck treatments. The five-point masks have the advantage that the patient's shoulders as well as the cranial part of the patient's head is covered with the thermoplastic material that improves the overall immobilization of the head and neck region of the patient. Thirteen patients were consecutively assigned to use a five-point thermoplastic mask. The patients were positioned by tracking of infrared markers (IR) fixed to the immobilization device and stereoscopic x-ray images were used for daily on-line setup verification. Repositioning was carried out prior to treatment as needed; rotations were not corrected. Movements during treatment were monitored by real-time IR tracking. Intrafraction motion and rotation was supplementary assessed by a six-degree-of-freedom (6-D) fusion of x-ray images, taken before and after all 385 treatments, with DRR images generated from the planning CT data. The latter evaluates the movement of the patient within the thermoplastic mask independent from the mask movement, where IR tracking evaluates the movement of the mask caused by patient movement in the mask. These two movements are not necessarily equal to each other. The maximum intrafraction movement detected by IR tracking showed a shift [mean (SD; range)] of -0.1(0.7; 6.0), 0.1(0.6; 3.6), -0.2(0.8;5.5) mm in the vertical, longitudinal, and lateral direction, respectively, and rotations of 0.0(0.2; 1.6), 0.0(0.2; 1.7) and 0.2(0.2; 2.4) degrees about the vertical, longitudinal, and lateral axis, respectively. The standard deviations

  14. Measuring interfraction and intrafraction lung function changes during radiation therapy using four-dimensional cone beam CT ventilation imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney NSW 2006 (Australia); Hugo, Geoffrey; Weiss, Elisabeth; Williamson, Jeffrey [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2015-03-15

    }=0.52±0.25, which was significantly lower than for intrafraction pairs (r{sup -}{sub Intra}=0.67±0.20, p = 0.0002). Conversely, mean absolute ventilation differences were larger for interfraction pairs than for intrafraction pairs, with |ΔV{sup -}{sub Inter}|=0.42±0.65 and |ΔV{sup -}{sub Intra}|=0.32±0.53, respectively (p < 10{sup −15}). Applying a gamma analysis with ventilation/distance tolerance of 25%/10 mm, we observed mean pass rate of (69% ± 20%) for interfraction VIs, which was significantly lower compared to intrafraction pairs (80% ± 15%, with p ∼ 0.0003). Compared to the first day scans, all patients experienced at least one subsequent change in median ipsilateral ventilation ≥10%. Patients experienced both positive and negative ventilation changes throughout treatment, with the maximum change occurring at different weeks for different patients. Conclusions: The authors’ data support the hypothesis that interfraction ventilation changes are larger than intrafraction ventilation changes for LA-NSCLC patients over a course of conventional lung cancer radiation therapy. Longitudinal ventilation changes are observed to be highly patient-dependent, supporting a possible role for adaptive ventilation guidance based on repeat 4D-CBCT VIs. We anticipate that future improvement of 4D-CBCT image reconstruction algorithms will improve the capability of 4D-CBCT VI to resolve interfraction ventilation changes.

  15. Measuring interfraction and intrafraction lung function changes during radiation therapy using four-dimensional cone beam CT ventilation imaging

    International Nuclear Information System (INIS)

    Kipritidis, John; Keall, Paul J.; Hugo, Geoffrey; Weiss, Elisabeth; Williamson, Jeffrey

    2015-01-01

    .25, which was significantly lower than for intrafraction pairs (r - Intra =0.67±0.20, p = 0.0002). Conversely, mean absolute ventilation differences were larger for interfraction pairs than for intrafraction pairs, with |ΔV - Inter |=0.42±0.65 and |ΔV - Intra |=0.32±0.53, respectively (p < 10 −15 ). Applying a gamma analysis with ventilation/distance tolerance of 25%/10 mm, we observed mean pass rate of (69% ± 20%) for interfraction VIs, which was significantly lower compared to intrafraction pairs (80% ± 15%, with p ∼ 0.0003). Compared to the first day scans, all patients experienced at least one subsequent change in median ipsilateral ventilation ≥10%. Patients experienced both positive and negative ventilation changes throughout treatment, with the maximum change occurring at different weeks for different patients. Conclusions: The authors’ data support the hypothesis that interfraction ventilation changes are larger than intrafraction ventilation changes for LA-NSCLC patients over a course of conventional lung cancer radiation therapy. Longitudinal ventilation changes are observed to be highly patient-dependent, supporting a possible role for adaptive ventilation guidance based on repeat 4D-CBCT VIs. We anticipate that future improvement of 4D-CBCT image reconstruction algorithms will improve the capability of 4D-CBCT VI to resolve interfraction ventilation changes

  16. Interfractional changes in tumour volume and position during entire radiotherapy courses for lung cancer with respiratory gating and image guidance

    DEFF Research Database (Denmark)

    Juhler-Nøttrup, Trine; Korreman, Stine Sofia; Pedersen, Anders N

    2008-01-01

    were contoured on each CT scan to evaluate the variations in volumes and position. The lung tumours and the mediastinal tumours were contoured separately. The positional variations were measured as 3D mobility vectors and correlated to matching of the scans using the two different strategies. RESULTS......-87% when matched using bony landmarks and 70-76% when matched using skin tattoos. The overlap of the mediastinal tumours were 60-65% and 41-47%, respectively. CONCLUSIONS: Despite the use of gating the tumours varied considerably, regarding both position and volume. The variations in position were...

  17. Patterns of intrafractional motion and uncertainties of treatment setup reference systems in accelerated partial breast irradiation for right- and left-sided breast cancer.

    Science.gov (United States)

    Yue, Ning J; Goyal, Sharad; Kim, Leonard H; Khan, Atif; Haffty, Bruce G

    2014-01-01

    This study investigated the patterns of intrafractional motion and accuracy of treatment setup strategies in 3-dimensional conformal radiation therapy of accelerated partial breast irradiation (APBI) for right- and left-sided breast cancers. Sixteen right-sided and 17 left-sided breast cancer patients were enrolled in an institutional APBI trial in which gold fiducial markers were strategically sutured to the surgical cavity walls. Daily pre- and postradiation therapy kV imaging were performed and were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion. The positioning differences of the laser-tattoo and the bony anatomy-based setups with respect to the marker-based setup (benchmark) were determined to evaluate their accuracy. Statistical differences were found between the right- and left-sided APBI treatments in vector directions of intrafractional motion and treatment setup errors in the reference systems, but less in their overall magnitudes. The directional difference was more pronounced in the lateral direction. It was found that the intrafractional motion and setup reference systems tended to deviate in the right direction for the right-sided breast treatments and in the left direction for the left-sided breast treatments. It appears that the fiducial markers placed in the seroma cavity exhibit side dependent directional intrafractional motion, although additional data may be needed to further validate the conclusion. The bony anatomy-based treatment setup improves the accuracy over laser-tattoo. But it is inadequate to rely on bony anatomy to assess intrafractional target motion in both magnitude and direction. Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  18. Six-dimensional correction of intra-fractional prostate motion with CyberKnife stereotactic body radiation therapy

    Directory of Open Access Journals (Sweden)

    Sean eCollins

    2011-12-01

    Full Text Available AbstractLarge fraction radiation therapy offers a shorter course of treatment and radiobiological advantages for prostate cancer treatment. The CyberKnife is an attractive technology for delivering large fraction doses based on the ability to deliver highly conformal radiation therapy to moving targets. In addition to intra-fractional translational motion (left-right, superior-inferior and anterior-posterior, prostate rotation (pitch, roll and yaw can increase geographical miss risk. We describe our experience with six-dimensional (6D intrafraction prostate motion correction using CyberKnife stereotactic body radiation therapy (SBRT. Eighty-eight patients were treated by SBRT alone or with supplemental external radiation therapy. Trans-perineal placement of four gold fiducials within the prostate accommodated X-ray guided prostate localization and beam adjustment. Fiducial separation and non-overlapping positioning permitted the orthogonal imaging required for 6D tracking. Fiducial placement accuracy was assessed using the CyberKnife fiducial extraction algorithm. Acute toxicities were assessed using Common Toxicity Criteria (CTC v3. There were no Grade 3, or higher, complications and acute morbidity was minimal. Ninety-eight percent of patients completed treatment employing 6D prostate motion tracking with intrafractional beam correction. Suboptimal fiducial placement limited treatment to 3D tracking in 2 patients. Our experience may guide others in performing 6D correction of prostate motion with CyberKnife SBRT.

  19. Spine Stereotactic Body Radiotherapy Utilizing Cone-Beam CT Image-Guidance With a Robotic Couch: Intrafraction Motion Analysis Accounting for all Six Degrees of Freedom

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, Derek [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Ontario (Canada); British Columbia Cancer Agency, The Sindi Hawkins Cancer Centre for the Southern Interior, Kelowna (Canada); Lochray, Fiona; Korol, Renee; Davidson, Melanie; Wong, C. Shun [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Ontario (Canada); Ma, Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA (United States); Sahgal, Arjun, E-mail: Arjun.sahgal@rmp.uhn.on.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto (Canada)

    2012-03-01

    Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom. Methods and Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image. For 13 single-fraction SBRT patients, two midtreatment CBCT images were obtained. Initially, a 1.5-mm and 1 Degree-Sign tolerance was used to reposition the patient following couch shifts which was subsequently reduced to 1 mm and 1 Degree-Sign degree after the first 10 patients. Results: Small positioning errors after the initial CBCT setup were observed, with 90% occurring within 1 mm and 97% within 1 Degree-Sign . In analyzing the impact of the time interval for verification imaging (10 {+-} 3 min) and subsequent image acquisitions (17 {+-} 4 min), the residual setup error was not significantly different (p > 0.05). A significant difference (p = 0.04) in the average three-dimensional intrafraction positional deviations favoring a more strict tolerance in translation (1 mm vs. 1.5 mm) was observed. The absolute intrafraction motion averaged over all patients and all directions along x, y, and z axis ({+-} SD) were 0.7 {+-} 0.5 mm and 0.5 {+-} 0.4 mm for the 1.5 mm and 1 mm tolerance, respectively. Based on a 1-mm and 1 Degree-Sign correction threshold, the target was localized to within 1.2 mm and 0.9 Degree-Sign with 95% confidence. Conclusion: Near-rigid body immobilization, intrafraction CBCT imaging approximately every 15-20 min, and strict repositioning thresholds in six degrees of freedom yields minimal intrafraction motion

  20. Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Maddalena M.G.; Peulen, Heike M.U.; Belderbos, Josè S.A.; Sonke, Jan-Jakob, E-mail: j.sonke@nki.nl

    2016-06-01

    Purpose: Stereotactic body radiation therapy (SBRT) for early-stage inoperable non-small cell lung cancer (NSCLC) patients delivers high doses that require high-precision treatment. Typically, image guidance is used to minimize day-to-day target displacement, but intrafraction position variability is often not corrected. Currently, volumetric modulated arc therapy (VMAT) is replacing intensity modulated radiation therapy (IMRT) in many departments because of its shorter delivery time. This study aimed to evaluate whether intrafraction variation in VMAT patients is reduced in comparison with patients treated with IMRT. Methods and Materials: NSCLC patients (197 IMRT and 112 VMAT) treated with a frameless SBRT technique to a prescribed dose of 3 × 18 Gy were evaluated. Image guidance for both techniques was identical: pretreatment cone beam computed tomography (CBCT) (CBCT{sub precorr}) for setup correction followed immediately before treatment by postcorrection CBCT (CBCT{sub postcorr}) for verification. Then, after either a noncoplanar IMRT technique or a VMAT technique, a posttreatment (CBCT{sub postRT}) scan was acquired. The CBCT{sub postRT} and CBCT{sub postcorr} scans were then used to evaluate intrafraction motion. Treatment delivery times, systematic (Σ) and random (σ) intrafraction variations, and associated planning target volume (PTV) margins were calculated. Results: The median treatment delivery time was significantly reduced by 20 minutes (range, 32-12 minutes) using VMAT compared with noncoplanar IMRT. Intrafraction tumor motion was significantly larger for IMRT in all directions up to 0.5 mm systematic (Σ) and 0.7 mm random (σ). The required PTV margins for IMRT and VMAT differed by less than 0.3 mm. Conclusion: VMAT-based SBRT for NSCLC was associated with significantly shorter delivery times and correspondingly smaller intrafraction motion compared with noncoplanar IMRT. However, the impact on the required PTV margin was small.

  1. Artificial neural network based gynaecological image-guided adaptive brachytherapy treatment planning correction of intra-fractional organs at risk dose variation.

    Science.gov (United States)

    Jaberi, Ramin; Siavashpour, Zahra; Aghamiri, Mahmoud Reza; Kirisits, Christian; Ghaderi, Reza

    2017-12-01

    Intra-fractional organs at risk (OARs) deformations can lead to dose variation during image-guided adaptive brachytherapy (IGABT). The aim of this study was to modify the final accepted brachytherapy treatment plan to dosimetrically compensate for these intra-fractional organs-applicators position variations and, at the same time, fulfilling the dosimetric criteria. Thirty patients with locally advanced cervical cancer, after external beam radiotherapy (EBRT) of 45-50 Gy over five to six weeks with concomitant weekly chemotherapy, and qualified for intracavitary high-dose-rate (HDR) brachytherapy with tandem-ovoid applicators were selected for this study. Second computed tomography scan was done for each patient after finishing brachytherapy treatment with applicators in situ. Artificial neural networks (ANNs) based models were used to predict intra-fractional OARs dose-volume histogram parameters variations and propose a new final plan. A model was developed to estimate the intra-fractional organs dose variations during gynaecological intracavitary brachytherapy. Also, ANNs were used to modify the final brachytherapy treatment plan to compensate dosimetrically for changes in 'organs-applicators', while maintaining target dose at the original level. There are semi-automatic and fast responding models that can be used in the routine clinical workflow to reduce individually IGABT uncertainties. These models can be more validated by more patients' plans to be able to serve as a clinical tool.

  2. Artificial neural network based gynaecological image-guided adaptive brachytherapy treatment planning correction of intra-fractional organs at risk dose variation

    Directory of Open Access Journals (Sweden)

    Ramin Jaberi

    2017-12-01

    Full Text Available Purpose : Intra-fractional organs at risk (OARs deformations can lead to dose variation during image-guided adaptive brachytherapy (IGABT. The aim of this study was to modify the final accepted brachytherapy treatment plan to dosimetrically compensate for these intra-fractional organs-applicators position variations and, at the same time, fulfilling the dosimetric criteria. Material and methods : Thirty patients with locally advanced cervical cancer, after external beam radiotherapy (EBRT of 45-50 Gy over five to six weeks with concomitant weekly chemotherapy, and qualified for intracavitary high-dose-rate (HDR brachytherapy with tandem-ovoid applicators were selected for this study. Second computed tomography scan was done for each patient after finishing brachytherapy treatment with applicators in situ. Artificial neural networks (ANNs based models were used to predict intra-fractional OARs dose-volume histogram parameters variations and propose a new final plan. Results : A model was developed to estimate the intra-fractional organs dose variations during gynaecological intracavitary brachytherapy. Also, ANNs were used to modify the final brachytherapy treatment plan to compensate dosimetrically for changes in ‘organs-applicators’, while maintaining target dose at the original level. Conclusions : There are semi-automatic and fast responding models that can be used in the routine clinical workflow to reduce individually IGABT uncertainties. These models can be more validated by more patients’ plans to be able to serve as a clinical tool.

  3. Real-Time Dynamic MLC Tracking for Intensity Modulated Arc Therapy

    DEFF Research Database (Denmark)

    Falk, Marianne

    Motion management of intra-fraction tumour motion during radiotherapy treatment can be a challenging task in order to achieve tumour control as well as minimizing the dose to the surrounding healthy tissue. Real-time dynamic multileaf collimator (MLC) tracking is a novel method for intra-fraction...

  4. Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

    International Nuclear Information System (INIS)

    Tang, Shikui; Deville, Curtiland; Tochner, Zelig; Wang, Ken Kang-Hsin; McDonough, James; Vapiwala, Neha; Both, Stefan

    2014-01-01

    Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D 99 (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D 99 was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically

  5. Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Shikui, E-mail: shktang@gmail.com [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); ProCure Proton Therapy Center, Somerset, New Jersey (United States); Deville, Curtiland; Tochner, Zelig [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Wang, Ken Kang-Hsin [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); McDonough, James; Vapiwala, Neha; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2014-12-01

    Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a

  6. Relationship of Imaging Frequency and Planning Margin to Account for Intrafraction Prostate Motion: Analysis Based on Real-Time Monitoring Data

    International Nuclear Information System (INIS)

    Curtis, William; Khan, Mohammad; Magnelli, Anthony; Stephans, Kevin; Tendulkar, Rahul; Xia, Ping

    2013-01-01

    Purpose: Correction for intrafraction prostate motion becomes important for hypofraction treatment of prostate cancer. The purpose of this study was to estimate an ideal planning margin to account for intrafraction prostate motion as a function of imaging and repositioning frequency in the absence of continuous prostate motion monitoring. Methods and Materials: For 31 patients receiving intensity modulated radiation therapy treatment, prostate positions sampled at 10 Hz during treatment using the Calypso system were analyzed. Using these data, we simulated multiple, less frequent imaging protocols, including intervals of every 10, 15, 20, 30, 45, 60, 90, 120, 180, and 240 seconds. For each imaging protocol, the prostate displacement at the imaging time was corrected by subtracting prostate shifts from the subsequent displacements in that fraction. Furthermore, we conducted a principal component analysis to quantify the direction of prostate motion. Results: Averaging histograms of every 240 and 60 seconds for all patients, vector displacements of the prostate were, respectively, within 3 and 2 mm for 95% of the treatment time. A vector margin of 1 mm achieved 91.2% coverage of the prostate with 30 second imaging. The principal component analysis for all fractions showed the largest variance in prostate position in the midsagittal plane at 54° from the anterior direction, indicating that anterosuperior to inferoposterior is the direction of greatest motion. The smallest prostate motion is in the left-right direction. Conclusions: The magnitudes of intrafraction prostate motion along the superior-inferior and anterior-posterior directions are comparable, and the smallest motion is in the left-right direction. In the absence of continuous prostate motion monitoring, and under ideal circumstances, 1-, 2-, and 3-mm vector planning margins require a respective imaging frequency of every 15, 60, and 240 to account for intrafraction prostate motion while achieving

  7. Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy. Comparison of gold marker-based registrations with native MVCT

    Energy Technology Data Exchange (ETDEWEB)

    Wust, Peter; Joswig, Marc; Graf, Reinhold; Boehmer, Dirk; Beck, Marcus; Barelkowski, Thomasz; Budach, Volker; Ghadjar, Pirus [Charite Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany)

    2017-09-15

    For high-dose radiation therapy (RT) of prostate cancer, image-guided (IGRT) and intensity-modulated RT (IMRT) approaches are standard. Less is known regarding comparisons of different IGRT techniques and the resulting residual errors, as well as regarding their influences on dose distributions. A total of 58 patients who received tomotherapy-based RT up to 84 Gy for high-risk prostate cancer underwent IGRT based either on daily megavoltage CT (MVCT) alone (n = 43) or the additional use of gold markers (n = 15) under routine conditions. Planned Adaptive (Accuray Inc., Madison, WI, USA) software was used for elaborated offline analysis to quantify residual interfractional prostate positioning errors, along with systematic and random errors and the resulting safety margins after both IGRT approaches. Dosimetric parameters for clinical target volume (CTV) coverage and exposition of organs at risk (OAR) were also analyzed and compared. Interfractional as well as intrafractional displacements were determined. Particularly in the vertical direction, residual interfractional positioning errors were reduced using the gold marker-based approach, but dosimetric differences were moderate and the clinical relevance relatively small. Intrafractional prostate motion proved to be quite high, with displacements of 1-3 mm; however, these did not result in additional dosimetric impairments. Residual interfractional positioning errors were reduced using gold marker-based IGRT; however, this resulted in only slightly different final dose distributions. Therefore, daily MVCT-based IGRT without markers might be a valid alternative. (orig.) [German] Bei der hochdosierten Bestrahlung des Prostatakarzinoms sind die bildgesteuerte (IGRT) und die intensitaetsmodulierte Bestrahlung (IMRT) Standard. Offene Fragen gibt es beim Vergleich von IGRT-Techniken im Hinblick auf residuelle Fehler und Beeinflussungen der Dosisverteilung. Bei 58 Patienten, deren Hochrisiko-Prostatakarzinom am

  8. Interfractional changes in tumour volume and position during entire radiotherapy courses for lung cancer with respiratory gating and image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Juhler-Noettrup, Trine; Korreman, Stine S.; Pedersen, Anders N.; Persson, Gitte F.; Aarup, Lasse R.; Nystroem, Haakan; Olsen, Mikael; Tarnavski, Nikolai; Specht, Lena (Dept. of Radiation Oncology, The Finsen Centre, Copenhagen (Denmark))

    2008-08-15

    Introduction. With the purpose of implementing gated radiotherapy for lung cancer patients, this study investigated the interfraction variations in tumour size and internal displacement over entire treatment courses. To explore the potential of image guided radiotherapy (IGRT) the variations were measured using a set-up strategy based on imaging of bony landmarks and compared to a strategy using in room lasers, skin tattoos and cupper landmarks. Materials and methods. During their six week treatment course of 60Gy in 2Gy fractions, ten patients underwent 3 respiratory gated CT scans. The tumours were contoured on each CT scan to evaluate the variations in volumes and position. The lung tumours and the mediastinal tumours were contoured separately. The positional variations were measured as 3D mobility vectors and correlated to matching of the scans using the two different strategies. Results. The tumour size was significantly reduced from the first to the last CT scan. For the lung tumours the reduction was 19%, p=0.03, and for the mediastinal tumours the reduction was 34%, p=0.0007. The mean 3D mobility vector and the SD for the lung tumours was 0.51cm (+-0.21) for matching using bony landmarks and 0.85cm (+-0.54) for matching using skin tattoos. For the mediastinal tumours the corresponding vectors and SD's were 0.55cm (+-0.19) and 0.72cm (+-0.43). The differences between the vectors were significant for the lung tumours p=0.004. The interfractional overlap of lung tumours was 80-87% when matched using bony landmarks and 70-76% when matched using skin tattoos. The overlap of the mediastinal tumours were 60-65% and 41-47%, respectively. Conclusions. Despite the use of gating the tumours varied considerably, regarding both position and volume. The variations in position were dependent on the set-up strategy. Set-up using IGRT was superior to set-up using skin tattoos.

  9. Interfractional changes in tumour volume and position during entire radiotherapy courses for lung cancer with respiratory gating and image guidance

    International Nuclear Information System (INIS)

    Juhler-Noettrup, Trine; Korreman, Stine S.; Pedersen, Anders N.; Persson, Gi tte F.; Aarup, Lasse R.; Nystroem, Haakan; Olsen, Mikael; Tarnavski, Nikolai; Sp echt, Lena

    2008-01-01

    Introduction. With the purpose of implementing gated radiotherapy for lung cancer patients, this study investigated the interfraction variations in tumour size and internal displacement over entire treatment courses. To explore the potential of image guided radiotherapy (IGRT) the variations were measured using a set-up strategy based on imaging of bony landmarks and compared to a strategy using in room lasers, skin tattoos and cupper landmarks. Materials and methods. During their six week treatment course of 60Gy in 2Gy fractions, ten patients underwent 3 respiratory gated CT scans. The tumours were contoured on each CT scan to evaluate the variations in volumes and position. The lung tumours and the mediastinal tumours were contoured separately. The positional variations were measured as 3D mobility vectors and correlated to matching of the scans using the two different strategies. Results. The tumour size was significantly reduced from the first to the last CT scan. For the lung tumours the reduction was 19%, p=0.03, and for the mediastinal tumours the reduction was 34%, p=0.0007. The mean 3D mobility vector and the SD for the lung tumours was 0.51cm (±0.21) for matching using bony landmarks and 0.85cm (±0.54) for matching using skin tattoos. For the mediastinal tumours the corresponding vectors and SD's were 0.55cm (±0.19) and 0.72cm (±0.43). The differences between the vectors were significant for the lung tumours p=0.004. The interfractional overlap of lung tumours was 80-87% when matched using bony landmarks and 70-76% when matched using skin tattoos. The overlap of the mediastinal tumours were 60-65% and 41-47%, respectively. Conclusions. Despite the use of gating the tumours varied considerably, regarding both position and volume. The variations in position were dependent on the set-up strategy. Set-up using IGRT was superior to set-up using skin tattoos

  10. Management of three-dimensional intrafraction motion through real-time DMLC tracking

    International Nuclear Information System (INIS)

    Sawant, Amit; Venkat, Raghu; Srivastava, Vikram; Carlson, David; Povzner, Sergey; Cattell, Herb; Keall, Paul

    2008-01-01

    Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation delivery to targets moving in three dimensions. The algorithm obtains real-time information of target location from an independent position monitoring system and dynamically calculates MLC leaf positions to account for changes in target position. Initial studies were performed to evaluate the geometric accuracy of DMLC tracking of 3D target motion. In addition, dosimetric studies were performed on a clinical linac to evaluate the impact of real-time DMLC tracking for conformal, step-and-shoot (S-IMRT), dynamic (D-IMRT), and VMAT deliveries to a moving target. The efficiency of conformal and IMRT delivery in the presence of tracking was determined. Results show that submillimeter geometric accuracy in all three dimensions is achievable with DMLC tracking. Significant dosimetric improvements were observed in the presence of tracking for conformal and IMRT deliveries to moving targets. A gamma index evaluation with a 3%-3 mm criterion showed that deliveries without DMLC tracking exhibit between 1.7 (S-IMRT) and 4.8 (D-IMRT) times more dose points that fail the evaluation compared to corresponding deliveries with tracking. The efficiency of IMRT delivery, as measured in the lab, was observed to be significantly lower in case of tracking target motion perpendicular to MLC leaf travel compared to motion parallel to leaf travel. Nevertheless, these early results indicate that accurate, real-time DMLC tracking of 3D tumor motion is feasible and can potentially result in significant geometric and dosimetric advantages leading to more effective management of intrafraction motion

  11. INTER- AND INTRAFRACTION MOTION FOR STEREOTACTIC RADIOSURGERY IN DOGS AND CATS USING A MODIFIED BRAINLAB FRAMELESS STEREOTACTIC MASK SYSTEM.

    Science.gov (United States)

    Dieterich, Sonja; Zwingenberger, Allison; Hansen, Katherine; Pfeiffer, Isabella; Théon, Alain; Kent, Michael S

    2015-01-01

    Precise and accurate patient positioning is necessary when doing stereotactic radiosurgery (SRS) to ensure adequate dosing to the tumor and sparing of normal tissues. This prospective cross-sectional study aimed to assess feasibility of a commercially available modified frameless SRS positioning system for use in veterinary radiotherapy patients with brain tumors. Fifty-one dogs and 12 cats were enrolled. Baseline and verification CT images were acquired. The verification CT images from 32 dogs and five cats had sufficient images for fusion to baseline CT images. A rigid box-based fusion was performed to determine interfraction motion. Forty-eight dogs and 11 cats were assessed for intrafraction motion by cine CT. Seventy percent of dogs and 60% of cats had interfraction 3D vector translational shifts >1 mm, with mean values of 1.9 mm in dogs, and 1.8 mm in cats. In dogs muscle wasting was weakly correlated with translational shifts. The maximum angular interfraction motion observed was 6.3° (roll), 3.5° (pitch), and 3.3° (yaw). There was no correlation between angular interfraction motion and weight, brachycephaly, or muscle wasting. Fifty-seven percent of dogs and 50% of cats had respiration-related intrafraction motion. Of these, 4.5% of dogs and 10% of cats had intrafraction motion >1 mm. This study demonstrates the modified Brainlab system is feasible for SRS in dogs and cats. The smaller cranial size and difference in anatomy increases setup uncertainty in some animals beyond limits usually accepted in SRS. Image-guided positioning is recommended to achieve clinically acceptable setup accuracy (<1 mm) for SRS. © 2015 American College of Veterinary Radiology.

  12. Neurohypophysis granular cell tumours. Upon neurohypophysis rare tumours

    International Nuclear Information System (INIS)

    Barrande, G.; Kujas, M.; Gancel, A.; Turpin, G.; Bruckert, E.; Kuhn, J.M.; Luton, J.P.

    1995-01-01

    Granular cell tumours of neurohypophysis are rare. These tumours are more often encountered as incidental autopsy findings seen in up to 17 % of unselected adult autopsy cases. There are few reports of para-sellar granular cell tumours large enough to cause symptoms. We present three cases of neurohypophysis granular cell tumour and a review of the literature. In one patient, the asymptomatic granular cell tumour was incidentally discovered at surgical removal of a corticotrophic micro-adenoma. The remaining 2 patients had a symptomatic tumour which caused neurological symptoms such as visual disturbance and headaches and endocrine disorders such as hypopituitarism or hyper-prolactinaemia. In these 2 cases, computerized tomography showed a well-circumscribed, contrast-enhanced, intra-sellar and supra-sellar mass. Magnetic resonance imaging demonstrated an isointense gadolinium-enhanced mass in T1-weighted-images. Trans-sphenoidal partial resection was performed and histology was interpreted as a granular cell tumour. The immunohistochemical study was positive for glial fibrillary acidic protein (GEAP) and neuron specific enolase (NSE) in 1 of the 2 tumours and positive for S100 protein and vimentin in both tumours but negative for CD68. The histogenesis of neurohypophysis granular cell tumours is still controversial but ultrastructural and immunohistochemical studies support the theory that may arise from pituicytes, the glial cells of neurohypophysis. Management of these benign, slow growing, tumours is based mainly on neurosurgical resection. Data from the literature do not support a beneficial effect of post operative radiation therapy on postoperative recurrences. (authors). 23 refs., 4 figs., 1 tab

  13. In vivo imaging of chromogranin A-positive endocrine tumours by three-step monoclonal antibody targeting

    International Nuclear Information System (INIS)

    Siccardi, A.G.; Paganelli, G.; Pontiroli, A.E.; Pelagi, M.; Magnani, P.; Viale, G.; Faglia, G.; Fazio, F.

    1996-01-01

    The detection of chromogranins (Cg) by immunohistochemistry and serology represents a new in vitro diagnostic tool for endocrine tumours. We have recently reported on the feasibility of targeting chromogranin A (CgA) for in vivo detection of pituitary adenomas by immunoscintigraphy (ISG). The scintigraphic procedure, based on an anti-CgA monoclonal antibody and on the avidin-biotin three-step method (Cg-3S-ISG), was evaluated on a group of 29 consecutive patients with known or suspected endocrine tumours other than pituitary adenomas, i.e. medullary thyroid carcinoma, carcinoid, insulinoma and parathormone- or ACTH-producing tumours. Primary tumours (10) and recurrences (16) were visualised in 26 patients, whereas conventional imaging techniques (planar radiography, computerised tomography, magnetic resonance imaging and ultrasonography) failed to detect the tumour sites in ten of the same (Cg-3S-ISG-positive) patients. Therefore, these preliminary results indicate that Cg-3S-ISG, the first immunological method able to detect endocrine tumours in vivo, has a higher diagnostic accuracy than conventional imaging techniques (93.1% compared with 65.5%). (orig.). With 3 figs., 1 tab

  14. Motion monitoring during a course of lung radiotherapy with anchored electromagnetic transponders. Quantification of inter- and intrafraction motion and variability of relative transponder positions

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Daniela [German Cancer Research Center (DKFZ), Division of Medical Physics in Radiation Oncology, Heidelberg (Germany); National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg (Germany); Heidelberg University Hospital, Department of Radiation Oncology, Heidelberg (Germany); Nill, Simeon; Oelfke, Uwe [German Cancer Research Center (DKFZ), Division of Medical Physics in Radiation Oncology, Heidelberg (Germany); National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg (Germany); The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Joint Department of Physics, London (United Kingdom); Roeder, Falk [German Cancer Research Center (DKFZ), Clinical Cooperation Unit Molecular Radiooncology, Heidelberg (Germany); University of Munich (LMU), Department of Radiation Oncology, Munich (Germany); Gompelmann, Daniela; Herth, Felix [University of Heidelberg, Pneumology and Critical Care Medicine, Thoraxklinik, Heidelberg (Germany); German Center for Lung Research, Translational Lung Research Center Heidelberg (TLRC), Heidelberg (Germany)

    2017-10-15

    Anchored electromagnetic transponders for tumor motion monitoring during lung radiotherapy were clinically evaluated. First, intrafractional motion patterns were analyzed as well as their interfractional variations. Second, intra- and interfractional changes of the geometric transponder positions were investigated. Intrafractional motion data from 7 patients with an upper or middle lobe tumor and three implanted transponders each was used to calculate breathing amplitudes, overall motion amount and motion midlines in three mutual perpendicular directions and three-dimensionally (3D) for 162 fractions. For 6 patients intra- and interfractional variations in transponder distances and in the size of the triangle defined by the transponder locations over the treatment course were determined. Mean 3D values of all fractions were up to 4.0, 4.6 and 3.4 mm per patient for amplitude, overall motion amount and midline deviation, respectively. Intrafractional transponder distances varied with standard deviations up to 3.2 mm, while a maximal triangle shrinkage of 36.5% over 39 days was observed. Electromagnetic real-time motion monitoring was feasible for all patients. Detected respiratory motion was on average modest in this small cohort without lower lobe tumors, but changes in motion midline were of the same size as the amplitudes and greater midline motion can be observed in some fractions. Intra- and interfractional variations of the geometric transponder positions can be large, so for reliable motion management correlation between transponder and tumor motion needs to be evaluated per patient. (orig.) [German] Verankerte, elektromagnetische Transponder fuer die Bewegungserkennung des Tumors waehrend der Strahlentherapie der Lunge wurden klinisch evaluiert. Dafuer wurden intrafraktionelle Bewegungsmuster und ihre interfraktionellen Variationen analysiert und intra- und interfraktionelle Veraenderungen der geometrischen Transponderpositionen untersucht. Intrafraktionelle

  15. A stable neurotensin-based radiopharmaceutical for targeted imaging and therapy of neurotensin receptor-positive tumours

    International Nuclear Information System (INIS)

    Garcia-Garayoa, Elisa; Blaeuenstein, Peter; Blanc, Alain; Maes, Veronique; Tourwe, Dirk; Schubiger, P.A.

    2009-01-01

    Neurotensin (NT) and its high affinity receptor (NTR1) are involved in several neoplastic processes. Thus, NT-based radiopharmaceuticals are potential tracers for targeted diagnosis and therapy of NTR-positive tumours. A new analogue based on NT(8-13), NT-XIX, with the three enzymatic cleavage sites stabilised, was synthesised and tested. The synthesis was performed by Boc strategy. Labelling with 99m Tc/ 188 Re was performed using the tricarbonyl technique. Metabolic stability was tested in vitro and in vivo. NT-XIX was further characterised in vitro in HT-29 cells and in vivo in nude mice with HT-29 xenografts. NT-XIX showed much longer half-lives than non-stabilised analogues. Binding to NTR1 was highly specific, although the affinity was lower than that of natural NT. Bound activity rapidly internalised into HT-29 cells and 50% remained trapped after 24 h. In the time-course biodistribution, the highest uptake was found in the tumour at all p.i. times. In vivo uptake was specific, and accumulation of activity in the kidneys was low. Radioactivity clearance from healthy organs was faster than that from the tumour, resulting in improved tumour-to-tissue ratios and good SPECT/CT imaging. Treatment with 188 Re-NT-XIX (30 MBq, in three or four fractions) decreased tumour growth by 50% after 3 weeks. The high in vivo stability and the favourable in vivo behaviour makes NT-XIX an excellent candidate for the imaging and therapy of NTR1-positive tumours. (orig.)

  16. Evaluation of intrafraction patient movement for CNS and head and neck IMRT

    International Nuclear Information System (INIS)

    Kim, Siyong; Akpati, Hilary C.; Kielbasa, Jerrold E.; Li, Jonathan G.; Liu, Chihray; Amdur, Robert J.; Palta, Jatinder R.

    2004-01-01

    Intrafraction patient motion is much more likely in intensity-modulated radiation therapy (IMRT) than in conventional radiotherapy primarily due to longer beam delivery times in IMRT treatment. In this study, we evaluated the uncertainty of intrafraction patient displacement in CNS and head and neck IMRT patients. Immobilization is performed in three steps: (1) the patient is immobilized with thermoplastic facemask, (2) the patient displacement is monitored using a commercial stereotactic infrared IR camera (ExacTrac, BrainLab) during treatment, and (3) repositioning is carried out as needed. The displacement data were recorded during beam-on time for the entire treatment duration for 5 patients using the camera system. We used the concept of cumulative time versus patient position uncertainty, referred to as an uncertainty time histogram (UTH), to analyze the data. UTH is a plot of the accumulated time during which a patient stays within the corresponding movement uncertainty. The University of Florida immobilization procedure showed an effective immobilization capability for CNS and head and neck IMRT patients by keeping the patient displacement less than 1.5 mm for 95% of treatment time (1.43 mm for 1, and 1.02 mm for 1, and less than 1.0 mm for 3 patients). The maximum displacement was 2.0 mm

  17. Combined Inter- and Intrafractional Plan Adaptation Using Fraction Partitioning in Magnetic Resonance-guided Radiotherapy Delivery.

    Science.gov (United States)

    Lagerwaard, Frank; Bohoudi, Omar; Tetar, Shyama; Admiraal, Marjan A; Rosario, Tezontl S; Bruynzeel, Anna

    2018-04-05

    Magnetic resonance-guided radiation therapy (MRgRT) not only allows for superior soft-tissue setup and online MR-guidance during delivery but also for inter-fractional plan re-optimization or adaptation. This plan adaptation involves repeat MR imaging, organs at risk (OARs) re-contouring, plan prediction (i.e., recalculating the baseline plan on the anatomy of that moment), plan re-optimization, and plan quality assurance. In contrast, intrafractional plan adaptation cannot be simply performed by pausing delivery at any given moment, adjusting contours, and re-optimization because of the complex and composite nature of deformable dose accumulation. To overcome this limitation, we applied a practical workaround by partitioning treatment fractions, each with half the original fraction dose. In between successive deliveries, the patient remained in the treatment position and all steps of the initial plan adaptation were repeated. Thus, this second re-optimization served as an intrafractional plan adaptation at 50% of the total delivery. The practical feasibility of this partitioning approach was evaluated in a patient treated with MRgRT for locally advanced pancreatic cancer (LAPC). MRgRT was delivered in 40Gy in 10 fractions, with two fractions scheduled successively on each treatment day. The contoured gross tumor volume (GTV) was expanded by 3 mm, excluding parts of the OARs within this expansion to derive the planning target volume for daily re-optimization (PTV OPT ). The baseline GTVV 95%  achieved in this patient was 80.0% to adhere to the high-dose constraints for the duodenum, stomach, and bowel (V 33 Gy ViewRay Inc, Mountain View, USA) using video-assisted breath-hold in shallow inspiration. The dual plan adaptation resulted, for each partitioned fraction, in the generation of Plan PREDICTED1 , Plan RE-OPTIMIZED1  (inter-fractional adaptation), Plan PREDICTED2 , and Plan RE-OPTIMIZED2  (intrafractional adaptation). An offline analysis was

  18. Multifocal small bowel stromal tumours presenting with peritonitis in an HIV positive patient.

    Science.gov (United States)

    Mansoor, Ebrahim

    2014-01-01

    The most common mesenchymal tumour of the gastrointestinal tract is stromal tumours (GISTs). Symptomatic GISTs can present with complications such as haemorrhage, obstruction and perforation. Complete surgical resection with negative margins is the mainstay of treatment but may be imprudent on emergent occasion. Tyrosine-kinase inhibitors (TKIs) have been revolutionary in the treatment of GISTs and have resulted in improved outcomes. A 41 year old HIV positive male presented with an acute history of abdominal pain and obstructive symptoms. Clinical examination revealed sepsis and peritonitis. One of the several small bowel tumours discovered at exploratory laparotomy was necrotic and perforated. The perforated tumour alone was resected and a small bowel internal hernia reduced. The patient made an uneventful recovery and will be considered for TKI therapy with a view to later re-operation. GISTs very rarely perforate. The pathophysiology of stromal tumour necrosis is poorly understood. Multifocality and small bowel location are poor prognosticators and may occur in the setting of familial GISTs, specific syndromes and sporadic cases. There is no established association between HIV and GISTs. Perforation occurs infrequently in ≤8% of symptomatic cases and poses increased risk of local recurrence. The surgical management of perforation takes precedence in an emergency. The surgeon must however take cognisance of the adherence to ideal oncologic principles where feasible. TKI therapy is invaluable if a re-exploration is to be later considered. Copyright © 2014 The Author. Published by Elsevier Ltd.. All rights reserved.

  19. Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Winnie; Sahgal, Arjun [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Foote, Matthew [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Millar, Barbara-Ann; Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Letourneau, Daniel, E-mail: Daniel.letourneau@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada)

    2012-10-01

    Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image

  20. Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Li, Winnie; Sahgal, Arjun; Foote, Matthew; Millar, Barbara-Ann; Jaffray, David A.; Letourneau, Daniel

    2012-01-01

    Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1–T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins ± 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9° to 1.6°, respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup

  1. Determining intrafractional prostate motion using four dimensional ultrasound system

    DEFF Research Database (Denmark)

    Baker, Mariwan; Behrens, Claus F.

    2016-01-01

    , LR, and AP directions, respectively. The mean of the maximal intrafractional Euclidean distance (3D vector) was 0.9 +/- 0.6 mm. For 12 % of the fractions the maximal 3D vector displacements were larger than 2.0 mm. At only two fractions (4 %) displacements larger than 3. 0 mm were observed...

  2. Validation of a computational method for assessing the impact of intra-fraction motion on helical tomotherapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Meeks, Sanford L; Kupelian, Patrick A; Langen, Katja M [Department of Radiation Oncology, M D Anderson Cancer Center Orlando, 1400 South Orange Avenue, Orlando, FL 32806 (United States); Schnarr, Eric [TomoTherapy, Inc., 1240 Deming Way, Madison, WI 53717 (United States)], E-mail: wilfred.ngwa@orlandohealth.com

    2009-11-07

    In this work, a method for direct incorporation of patient motion into tomotherapy dose calculations is developed and validated. This computational method accounts for all treatment dynamics and can incorporate random as well as cyclical motion data. Hence, interplay effects between treatment dynamics and patient motion are taken into account during dose calculation. This allows for a realistic assessment of intra-fraction motion on the dose distribution. The specific approach entails modifying the position and velocity events in the tomotherapy delivery plan to accommodate any known motion. The computational method is verified through phantom and film measurements. Here, measured prostate motion and simulated respiratory motion tracks were incorporated in the dose calculation. The calculated motion-encoded dose profiles showed excellent agreement with the measurements. Gamma analysis using 3 mm and 3% tolerance criteria showed over 97% and 96% average of points passing for the prostate and breathing motion tracks, respectively. The profile and gamma analysis results validate the accuracy of this method for incorporating intra-fraction motion into the dose calculation engine for assessment of dosimetric effects on helical tomotherapy dose deliveries.

  3. Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy

    International Nuclear Information System (INIS)

    Eccles, Cynthia; Brock, Kristy K.; Bissonnette, Jean-Pierre; Hawkins, Maria; Dawson, Laura A.

    2006-01-01

    Purpose: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT). Methods: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment. Results: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0

  4. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  5. Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

    International Nuclear Information System (INIS)

    Shah, Chirag; Grills, Inga S.; Kestin, Larry L.; McGrath, Samuel; Ye Hong; Martin, Shannon K.; Yan Di

    2012-01-01

    Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 ± 1.8 mm, 0.1 ± 1.9 mm, and 0.01 ± 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 ± 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

  6. Differences in abdominal organ movement between supine and prone positions measured using four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Kim, Young Seok; Park, Sung Ho; Ahn, Seung Do; Lee, Jeong Eun; Choi, Eun Kyung; Lee, Sang-wook; Shin, Seong Soo; Yoon, Sang Min; Kim, Jong Hoon

    2007-01-01

    Background and purpose: To analyze the differences in intrafractional organ movement throughout the breathing cycles between the supine and prone positions using four-dimensional computed tomography (4D CT). Materials and methods: We performed 4D CT on nine volunteers in the supine and prone positions, with each examinee asked to breathe normally during scanning. The movement of abdominal organs in the cranio-caudal (CC), anterior-posterior (AP) and right-left (RL) directions was quantified by contouring on each phase between inspiration and expiration. Results: The mean intrafractional motions of the hepatic dome, lower tip, pancreatic head and tail, both kidneys, spleen, and celiac axis in the supine/prone position were 17.3/13.0, 14.4/11.0, 12.8/8.9, 13.0/10.0, 14.3/12.1, 12.3/12.6, 11.7/12.6 and 2.2/1.8 mm, respectively. Intrafractional movements of the liver dome and pancreatic head were reduced significantly in the prone position. The CC directional excursions were major determinants of the 3D displacements of the abdominal organs. Alteration from the supine to the prone position did not change the amount of intrafractional movements of kidneys, spleen, and celiac axis. Conclusion: There was a significant reduction in the movements of the liver and pancreas during the prone position, especially in the CC direction, suggesting possible advantage of radiotherapy to these organs in this position

  7. Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Eric T., E-mail: eric.t.shinohara@vanderbilt.edu [Department of Radiation Oncology, The Vanderbilt Clinic, Nashville, TN (United States); Kassaee, Alireza [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Mitra, Nandita [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Vapiwala, Neha; Plastaras, John P. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Drebin, Jeff [Department of Surgery, University of Pennsylvania, Philadelphia, PA (United States); Wan, Fei [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Metz, James M. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States)

    2012-06-01

    Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

  8. Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

    International Nuclear Information System (INIS)

    Shinohara, Eric T.; Kassaee, Alireza; Mitra, Nandita; Vapiwala, Neha; Plastaras, John P.; Drebin, Jeff; Wan, Fei; Metz, James M.

    2012-01-01

    Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System’s localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

  9. Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Shikui, E-mail: TangS@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Deville, Curtiland; McDonough, James; Tochner, Zelig [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Wang, Ken Kang-Hsin [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University, Baltimore, Maryland (United States); Vapiwala, Neha; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2013-10-01

    Purpose: To assess the dosimetric impact caused by the interplay between intrafraction prostate motion and the intermittent delivery of proton pencil beam scanning (PBS). Methods and Materials: A cohort of 10 prostate patients was treated with PBS using a bilateral single-field uniform dose (SFUD) modality. Bilateral intensity-modulated proton therapy (IMPT) plans were generated for comparison. Because beam-on time in PBS was intermittent, the actual beam-on time was determined from treatment logs. Prostate motion was generalized according to real-time Calypso tracking data from our previously reported prospective photon trial. We investigated potential dose deviations by considering the interplay effect resulting from the worst-case scenario motion and the PBS delivery sequence. Results: For both bilateral-field SFUD and IMPT plans, clinical target volume (CTV) D{sub 99}% coverage was degraded <2% owing to prostate intrafraction motion when averaged over the course of treatment, but was >10% for the worst fraction. The standard deviation of CTV D{sub 99}% distribution was approximately 1.2%. The CTV coverage of individual fields in SFUD plans degraded as time elapsed after the initial alignment, owing to prostate drift. Intensity-modulated proton therapy and SFUD demonstrated comparable results when bilateral opposed fields were used. Single-field SFUD plans that were repainted twice, which could reduce half of the treatment time, resulted in similar CTV coverage as bilateral-field plans. Conclusions: Intrafraction prostate motion affects the actual delivered dose to CTV; however, when averaged over the course of treatment, CTV D{sub 99}% coverage degraded only approximately 2% even for the worst-case scenario. The IMPT plan results are comparable to those of the SFUD plan, and similar coverage can be achieved if treated by SFUD 1 lateral field per day when rescanning the field twice to shorten the treatment time and mitigate intrafraction motion.

  10. A positive 111in-pentetreotide scan in a patient with a pancreatic polypeptide secreting tumour

    International Nuclear Information System (INIS)

    Stanton, K.; Cehic, G.

    2003-01-01

    Full text: A 55-year-old male presented to our department with a known polypeptide secreting pancreatic tumour. An 111 In-pentetreotide scan (OctreoScan) was performed to determine whether the tumour expressed somatostatin receptors (SR) and thereby aid in therapy planning. 120 MBq 111 In-pentetreotide was administered intravenously. Images were acquired at 4 and 30 hours. Whole body images were acquired with spot views and tomography of the liver at 30 hours. Images showed intense uptake of the tracer in the lobular midline pancreatic mass. There was also uptake in multiple liver metastases. 111 In-pentetreotide is a synthetic somatostatin analogue and its uptake demonstrates the presence of SR on tumour cells, especially those of a neuro-endocrine nature. A 123 I Metaiodobenzylguanidine (MIBG) scan was also performed to determine whether the more widely available MIBG therapy would be appropriate for this patient. This scan was negative. The patient has received 3 cycles of chemotherapy with Streptozotocin and 5-fluorouracil. He has had a good partial response to therapy as demonstrated on CT scan. The patient is currently clinically well, his symptoms have resolved and weight stabilised. Good biochemical response to chemotherapy is indicated by halved pancreatic peptide levels. To date chemotherapy has been the mainstay of therapy for neuroendocrine tumours. Radioimmunotherapy (targeted to SR positive tumours) is currently being investigated as a therapy alternative and may be a future treatment option. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. SU-E-J-258: Inter- and Intra-Fraction Setup Stability and Couch Change Tolerance for Image Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Teboh, Forbang R; Agee, M; Rowe, L; Creasy, T; Schultz, J; Bell, R; Wong, J; Armour, E

    2014-01-01

    Purpose: Immobilization devices combine rigid patient fixation as well as comfort and play a key role providing the stability required for accurate radiation delivery. In the setup step, couch re-positioning needed to align the patient is derived via registration of acquired versus reference image. For subsequent fractions, replicating the initial setup should yield identical alignment errors when compared to the reference. This is not always the case and further couch re-positioning can be needed. An important quality assurance measure is to set couch tolerances beyond which additional investigations are needed. The purpose of this work was to study the inter-fraction couch changes needed to re-align the patient and the intra-fraction stability of the alignment as a guide to establish the couch tolerances. Methods: Data from twelve patients treated on the Accuray CyberKnife (CK) system for fractionated intracranial radiotherapy and immobilized with Aquaplast RT, U-frame, F-Head-Support (Qfix, PA, USA) was used. Each fraction involved image acquisitions and registration with the reference to re-align the patient. The absolute couch position corresponding to the approved setup alignment was recorded per fraction. Intra-fraction set-up corrections were recorded throughout the treatment. Results: The average approved setup alignment was 0.03±0.28mm, 0.15±0.22mm, 0.06±0.31mm in the L/R, A/P, S/I directions respectively and 0.00±0.35degrees, 0.03±0.32degrees, 0.08±0.45degrees for roll, pitch and yaw respectively. The inter-fraction reproducibility of the couch position was 6.65mm, 10.55mm, and 4.77mm in the L/R, A/P and S/I directions respectively and 0.82degrees, 0.71degrees for roll and pitch respectively. Intra-fraction monitoring showed small average errors of 0.21±0.21mm, 0.00±0.08mm, 0.23±0.22mm in the L/R, A/P, S/I directions respectively and 0.03±0.12degrees, 0.04±0.25degrees, and 0.13±0.15degrees in the roll, pitch and yaw respectively. Conclusion

  12. SU-E-J-258: Inter- and Intra-Fraction Setup Stability and Couch Change Tolerance for Image Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Teboh, Forbang R; Agee, M; Rowe, L; Creasy, T; Schultz, J; Bell, R; Wong, J; Armour, E [Johns Hopkins University, Baltimore, MD (United States)

    2014-06-01

    Purpose: Immobilization devices combine rigid patient fixation as well as comfort and play a key role providing the stability required for accurate radiation delivery. In the setup step, couch re-positioning needed to align the patient is derived via registration of acquired versus reference image. For subsequent fractions, replicating the initial setup should yield identical alignment errors when compared to the reference. This is not always the case and further couch re-positioning can be needed. An important quality assurance measure is to set couch tolerances beyond which additional investigations are needed. The purpose of this work was to study the inter-fraction couch changes needed to re-align the patient and the intra-fraction stability of the alignment as a guide to establish the couch tolerances. Methods: Data from twelve patients treated on the Accuray CyberKnife (CK) system for fractionated intracranial radiotherapy and immobilized with Aquaplast RT, U-frame, F-Head-Support (Qfix, PA, USA) was used. Each fraction involved image acquisitions and registration with the reference to re-align the patient. The absolute couch position corresponding to the approved setup alignment was recorded per fraction. Intra-fraction set-up corrections were recorded throughout the treatment. Results: The average approved setup alignment was 0.03±0.28mm, 0.15±0.22mm, 0.06±0.31mm in the L/R, A/P, S/I directions respectively and 0.00±0.35degrees, 0.03±0.32degrees, 0.08±0.45degrees for roll, pitch and yaw respectively. The inter-fraction reproducibility of the couch position was 6.65mm, 10.55mm, and 4.77mm in the L/R, A/P and S/I directions respectively and 0.82degrees, 0.71degrees for roll and pitch respectively. Intra-fraction monitoring showed small average errors of 0.21±0.21mm, 0.00±0.08mm, 0.23±0.22mm in the L/R, A/P, S/I directions respectively and 0.03±0.12degrees, 0.04±0.25degrees, and 0.13±0.15degrees in the roll, pitch and yaw respectively. Conclusion

  13. Mid-ventilation position planning: Optimal model for dose distribution in lung tumour

    International Nuclear Information System (INIS)

    Benchalal, M.; Leseur, J.; Chajon, E.; Cazoulat, G.; Haigron, P.; Simon, A.; Bellec, J.; Lena, H.; Crevoisier, R. de

    2012-01-01

    Purpose. - The dose distribution for lung tumour is estimated using a 3D-CT scan, and since a person breathes while the images are captured, the dose distribution doesn't reflect the reality. A 4D-CT scan integrates the motion of the tumour during breathing and, therefore, provides us with important information regarding tumour's motion in all directions, the motion volume (ITV) and the time-weighted average position (MVP). Patient and methods. - Based on these two concepts, we have estimated, for a lung carcinoma case a 3D dose distribution from a 3D-CT scan, and a 4D dose distribution from a 4-D CT scan. To this, we have applied a non-rigid registration to estimate the cumulative dose. Results. - Our study shows that the 4D dose estimation of the GTV is almost the same when made using MVP and ITV concepts, but sparring of the healthy lung is better done using the MPV model (MVP), as compared to the ITV model. This improvement of the therapeutic index allows, from a projection on the theoretical maximal dose to PTV (strictly restricted to doses for the lungs and the spinal cord), for an increase of about 11% on the total dose (maximal dose of 86 Gy for the ITV and 96 Gy for the MVP). Conclusion. - Further studies with more patients are needed to confirm our data. (authors)

  14. Nuclear expression of Snail1 in borderline and malignant epithelial ovarian tumours is associated with tumour progression

    International Nuclear Information System (INIS)

    Tuhkanen, Hanna; Soini, Ylermi; Kosma, Veli-Matti; Anttila, Maarit; Sironen, Reijo; Hämäläinen, Kirsi; Kukkonen, Laura; Virtanen, Ismo; Mannermaa, Arto

    2009-01-01

    Transcription factor Snail1 has a central role in induction of epithelial-mesenchymal transition (EMT). The aim of the present study was to elucidate the expression of Snail1 protein during epithelial ovarian tumourigenesis and to study the association of Snail1 expression with clinicopathological factors and prognosis. Epithelial and stromal fibroblast-like fusiform cells of 14 normal ovarian samples, 21 benign, 24 borderline and 74 malignant epithelial ovarian tumours were studied for Snail1 protein using immunohistochemistry. Nuclei of surface peritoneal cells of normal ovaries (n = 14) were regarded as negative for Snail1. Nuclear expression of Snail1 protein in epithelial ovarian tumours was increased during tumour progression from precursor lesions into carcinomas both in epithelial (p = 0.006) and stromal cells (p = 0.007). Nuclei of benign tumours (n = 21) were negative for Snail1. In borderline tumours (n = 24) occasional positive epithelial cells were found in 2 (8%) samples and in 3 (13%) samples stromal cells were focally positive for Snail1. In carcinomas (n = 74) focal Snail1 staining in epithelial cells was present in 17 (23%) tumours, and in stromal cells in 18 (24%) tumours. Nuclear expression of Snail1 in epithelial or stromal cells was not associated with clinicopathological factors or prognosis. Nuclear Snail1 expression seems to be related to tumour progression, and expression in borderline tumours indicates a role for Snail1 in early epithelial ovarian tumour development. Snail1 also appears to function more generally in tissue remodelling as positive staining was demonstrated in stromal cells

  15. SU-G-JeP4-07: Evaluation of Intrafraction Motion Using 3D Surface Guided Radiation Therapy in Lung SBRT

    International Nuclear Information System (INIS)

    Jermoumi, M; Cao, D; Mehta, V; Shepard, D

    2016-01-01

    Purpose: Surface guided radiation therapy (SGRT) uses stereoscopic video images in combination with patterns projected onto the patient’s surface to dynamically capture and reconstruct a 3D surface map. In this work, we used a C-RAD Catalyst HD system (C-RAD) to evaluate intrafraction motion in the delivery of lung SBRT. Methods: The surface acquired from the 4DCT images from our preliminary cohort of eight lung cancer patients treated with SBRT were matched to the surface images acquired prior to each treatment. Additionally, a CBCT image set was acquired. A linear regression model was established between the external and internal motion of tumor during pretreatment and used to predict the CBCT deviation during treatment. The shifts determined from CBCT and the shifts from surface map imaging were compared and assessed using Bland-Altman method. For intrafraction motion, we assessed the percentage of mean errors that fell outside of the threshold of 2 mm, 3 mm, and 5 mm along the translational directions. The required PTV margin was quantified over the course of treatment. The correlation between intrafraction treatment time and mean error of 3D displacement was evaluated using the Pearson coefficient, r Results: A total of 7971 data points were analyzed. Deviations of 2mm, 3mm, and 5mm were observed less than 7%, 2 %, and 0 % of the time along the translational direction. CBCT and Catalyst showed close agreement during patient positioning. Furthermore, the calculated PTV margins were less than our clinical tolerance of 5 mm. Using the Pearson coefficient r,the mean error of 3D displacement showed significant correlation with treatment time (r=0.69, p= 0.000002). Conclusion: SGRT can be used to ensure accurate patient positioning during treatment without an additional delivery of dose to the patient. This study shows that importance of treatment time as a consideration during the treatment planning process.

  16. SU-G-JeP4-07: Evaluation of Intrafraction Motion Using 3D Surface Guided Radiation Therapy in Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Jermoumi, M; Cao, D; Mehta, V; Shepard, D [Department of Radiation Oncology, Swedish Cancer Institute, Seattle, WA (United States)

    2016-06-15

    Purpose: Surface guided radiation therapy (SGRT) uses stereoscopic video images in combination with patterns projected onto the patient’s surface to dynamically capture and reconstruct a 3D surface map. In this work, we used a C-RAD Catalyst HD system (C-RAD) to evaluate intrafraction motion in the delivery of lung SBRT. Methods: The surface acquired from the 4DCT images from our preliminary cohort of eight lung cancer patients treated with SBRT were matched to the surface images acquired prior to each treatment. Additionally, a CBCT image set was acquired. A linear regression model was established between the external and internal motion of tumor during pretreatment and used to predict the CBCT deviation during treatment. The shifts determined from CBCT and the shifts from surface map imaging were compared and assessed using Bland-Altman method. For intrafraction motion, we assessed the percentage of mean errors that fell outside of the threshold of 2 mm, 3 mm, and 5 mm along the translational directions. The required PTV margin was quantified over the course of treatment. The correlation between intrafraction treatment time and mean error of 3D displacement was evaluated using the Pearson coefficient, r Results: A total of 7971 data points were analyzed. Deviations of 2mm, 3mm, and 5mm were observed less than 7%, 2 %, and 0 % of the time along the translational direction. CBCT and Catalyst showed close agreement during patient positioning. Furthermore, the calculated PTV margins were less than our clinical tolerance of 5 mm. Using the Pearson coefficient r,the mean error of 3D displacement showed significant correlation with treatment time (r=0.69, p= 0.000002). Conclusion: SGRT can be used to ensure accurate patient positioning during treatment without an additional delivery of dose to the patient. This study shows that importance of treatment time as a consideration during the treatment planning process.

  17. Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

    International Nuclear Information System (INIS)

    Beltran, Chris; Trussell, John; Merchant, Thomas E.

    2010-01-01

    The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 ± 1.5 treatment fractions; motion data were acquired for a mean of 26 ± 6.2 fractions. The mean age was 15.6 ± 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

  18. PET imaging for the quantification of biologically heterogeneous tumours: measuring the effect of relative position on image-based quantification of dose-painting targets

    International Nuclear Information System (INIS)

    McCall, Keisha C; Barbee, David L; Kissick, Michael W; Jeraj, Robert

    2010-01-01

    Quantitative imaging of tumours represents the foundation of customized therapies and adaptive patient care. As such, we have investigated the effect of patient positioning errors on the reproducibility of images of biologically heterogeneous tumours generated by a clinical PET/CT system. A commercial multi-slice PET/CT system was used to acquire 2D and 3D PET images of a phantom containing multiple spheres of known volumes and known radioactivity concentrations and suspended in an aqueous medium. The spheres served as surrogates for sub-tumour regions of biological heterogeneities with dimensions of 5-15 mm. Between image acquisitions, a motorized-arm was used to reposition the spheres in 1 mm intervals along either the radial or the axial direction. Images of the phantom were reconstructed using typical diagnostic reconstruction techniques, and these images were analysed to characterize and model the position-dependent changes in contrast recovery. A simulation study was also conducted to investigate the effect of patient position on the reproducibility of PET imaging of biologically heterogeneous head and neck (HN) tumours. For this simulation study, we calculated the changes in image intensity values that would occur with changes in the relative position of the patients at the time of imaging. PET images of two HN patients were used to simulate an imaging study that incorporated set-up errors that are typical for HN patients. One thousand randomized positioning errors were investigated for each patient. As a result of the phantom study, a position-dependent trend was identified for measurements of contrast recovery of small objects. The peak contrast recovery occurred at radial and axial positions that coincide with the centre of the image voxel. Conversely, the minimum contrast recovery occurred when the object was positioned at the edges of the image voxel. Changing the position of high contrast spheres by one-half the voxel dimension lead to errors in the

  19. A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

    International Nuclear Information System (INIS)

    Liu Wu; Luxton, Gary; Xing Lei

    2010-01-01

    Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

  20. Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Morris, Mallory N.; Merrick, Gregory S.; Kurko, Brian S.; Murray, Brian C.

    2012-01-01

    Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a “beam on” tag were used in the analysis. There were 21 obese patients, with BMI ≥30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 ± 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 ± 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI ≥30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

  1. WE-G-BRF-01: Adaptation to Intrafraction Tumor Deformation During Intensity-Modulated Radiotherapy: First Proof-Of-Principle Demonstration

    International Nuclear Information System (INIS)

    Ge, Y; OBrien, R; Shieh, C; Booth, J; Keall, P

    2014-01-01

    Purpose: Intrafraction tumor deformation limits targeting accuracy in radiotherapy and cannot be adapted to by current motion management techniques. This study simulated intrafractional treatment adaptation to tumor deformations using a dynamic Multi-Leaf Collimator (DMLC) tracking system during Intensity-modulated radiation therapy (IMRT) treatment for the first time. Methods: The DMLC tracking system was developed to adapt to the intrafraction tumor deformation by warping the planned beam aperture guided by the calculated deformation vector field (DVF) obtained from deformable image registration (DIR) at the time of treatment delivery. Seven single phantom deformation images up to 10.4 mm deformation and eight tumor system phantom deformation images up to 21.5 mm deformation were acquired and used in tracking simulation. The intrafraction adaptation was simulated at the DMLC tracking software platform, which was able to communicate with the image registration software, reshape the instantaneous IMRT field aperture and log the delivered MLC fields.The deformation adaptation accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the reference aperture. The incremental deformations were arbitrarily determined to take place equally over the delivery interval. The geometric target coverage of delivery with deformation adaptation was compared against the delivery without adaptation. Results: Intrafraction deformation adaptation during dynamic IMRT plan delivery was simulated for single and system deformable phantoms. For the two particular delivery situations, over the treatment course, deformation adaptation improved the target coverage by 89% for single target deformation and 79% for tumor system deformation compared with no-tracking delivery. Conclusion: This work demonstrated the principle of real-time tumor deformation tracking using a DMLC. This is the first step towards the development of an

  2. TU-F-CAMPUS-J-01: Inference of Prostate PTV Margins in VMAT Delivery From Intra-Fraction Prostate Motion During SBRT Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Thind, K; Wong, R; Gerdes, C; Chow, T [Juravinski Cancer Centre, Hamilton, Ontario (Canada); Wong, D [McMaster University, Hamilton, Ontario (Canada)

    2015-06-15

    Purpose: To retrospectively quantify the intra-fraction prostate motion during stereotactic body radiation therapy (SBRT) treatment using CyberKnife’s target tracking system, which may provide insight into expansion margins from GTV to PTV used in gantry-based treatments. CyberKnife is equipped with an active tracking system (InTempo) that tracks the four fiducials placed in the prostate gland. The system acquires intra-fraction orthogonal kV images at 45° and 315° in a sequential fashion. Methods: A total of 38 patients treated with SBRT using CyberKnife between 2011 and 2013 were studied. Dose-regime was 36.25 Gy in 5 fractions (7.25 Gy/fraction, twice per week) as per RTOG 0938 guidelines. The CyberKnife image tracking logs for all SBRT treatments using InTempo were examined. A total of 13663 images were examined for the superior/inferior (SI), anterior/posterior (AP) and left/right (LR) translation as well as roll, pitch and yaw rotations for the target position relative to the last known model position. Results: The mean ± 2 SD of intra-fraction motion was contained within 3 mm for SI and LR and 4.5 mm for AP directions at 5 minutes into the treatment delivery. It was contained within 4 mm for SI and LR and 5 mm for AP at 10 minutes. At 15 minutes into delivery, all translations were contained within 5 mm. The mean ± 2 SD of prostate roll, pitch and yaw increased with time but were contained within 5 degree at 5, 10 and 15 minutes into treatment. Additionally, target translations and rotations were within ± 1 mm and ± 1 degree for 90% and 78% of the time. Conclusion: The organ motion component of PTV margin for 10 minute VMAT delivery is contained within 4 mm in SI and LR direction and within 5 mm in the AP direction.

  3. [99mTc]Demotate 2 in the detection of sst2-positive tumours: a preclinical comparison with [111In]DOTA-tate

    International Nuclear Information System (INIS)

    Maina, Theodosia; Nock, Berthold A.; Cordopatis, Paul; Bernard, Bert F.; Breeman, Wout A.P.; Gameren, Arthur van; Berg, Ria van den; Krenning, Eric P.; Jong, Marion de; Reubi, Jean-Claude

    2006-01-01

    The aim of this study was to evaluate [ 99m Tc]Demotate 2 ([ 99m Tc-N 4 0-1 ,Asp 0 ,Tyr 3 ]octreotate) as a candidate for in vivo imaging of sst 2 -positive tumours and to compare it with [ 111 In]DOTA-tate ([ 111 In-DOTA 0 ,Tyr 3 ]octreotate). Labelling of Demotate 2 with 99m Tc was performed at room temperature using SnCl 2 as reductant in the presence of citrate at alkaline pH. Radiochemical analysis involved ITLC and HPLC methods. Peptide conjugate affinities for sst 2 were determined by receptor autoradiography on rat brain cortex sections using [DOTA 0 , 125 I-Tyr 3 ]octreotate as the radioligand. The affinity profile of Demotate 2 for human sst 1 -sst 5 was studied by receptor autoradiography in cell preparations using the universal somatostatin radioligand [ 125 I][Leu 8 ,(D)Trp 22 ,Tyr 25 ]somatostatin-28. The internalisation rates of [ 99m Tc]Demotate 2 and [ 111 In]DOTA-tate were compared in sst 2 -positive and -negative control cell lines. Biodistribution of radiopeptides was studied in male Lewis rats bearing CA20948 tumours. Peptide conjugates showed selectivity and a high affinity binding for sst 2 (Demotate 2 IC 50 =3.2 nM and DOTA-tate IC 50 =5.4 nM). [ 99m Tc]Demotate 2, like [ 111 In]DOTA-tate, internalised rapidly in all sst 2 -positive cells tested, but not in sst 2 -negative control cells. After injection in CA20948 tumour-bearing rats both radiopeptides showed high and specific uptake in the sst 2 -positive organs and in the implanted tumour and rapid excretion from non-target tissues via the kidneys. [ 99m Tc]Demotate 2, similarly to the known sst 2 -targeting agent [ 111 In]DOTA-tate, showed promising biological qualities for application in the scintigraphy of sst 2 -positive tumours. (orig.)

  4. 99mTc-HYNIC-somatostatin analogues for imaging SST receptor positive tumours, preclinical evaluation and comparison with 111In-Octreotide

    International Nuclear Information System (INIS)

    Decristoforo, C.; Melendez-Alafort, L.; Sosabowski, J.K.; Mather, S.J.

    2001-01-01

    HYNIC-TOC and HYNIC-RC-160 were prepared and radiolabelled at high specific activities using tricine, EDDA and tricine/nicotinic acid as co-ligand systems. Radioligand binding assays were performed on membranes prepared from receptor-positive cell lines. Biodistribution and tumour uptake were determined in AR42J tumour bearing nude mice and compared to 99m Tc-MAG-3-RC-160 and 111 In-DTPA-Octreotide. Specific tumour uptake between 2.4 and 9.6%ID/g was found for the 99m Tc labelled HYNIC-conjugates compared to 0.2% for the 99m Tc-MAG-3-RC-160 and 4.3% ID/g for 111 In-DTPA-Octreotide. RC-160 conjugates showed lower tumour uptake and greater hepatobiliary excretion than TOC. Tricine as co-ligand showed higher levels of radioactivity in muscle, blood and liver, while tricine/NA produced significant levels of activity in the GI-tract. EDDA showed the most promising overall biodistribution profile with similar tumour: liver and GI-tract ratios to those obtained with 111 In-DTPA-Octreotide, lower ratios in blood and muscle but considerably higher tumour/kidney ratios. (author)

  5. An assessment of the magnitude of intra-fraction movement of head-and-neck IMRT cases and its implication on the action-level of the imaging protocol

    International Nuclear Information System (INIS)

    Pang, Pei Ping Eric; Hendry, Julie; Cheah, Shie Lee; Soong, Yoke Lim; Fong, Kam Weng; Wee, Tien Seng Joseph; Tan, Wee Kiat Terence; Nei, Wen Long; Wang, Fuqiang; Wong, Ru Xin; Ng, Wee Loon; Chen, John

    2014-01-01

    Background and purpose: A planning margin ⩽3 mm is employed in some head-and-neck IMRT cases due to the proximity of critical structures. This study aims to explore the need to redefine the action-level in the head-and-neck imaging protocol in consideration of the intra-fraction movement. Material and methods: This is a local study of 18 patients treated using the same immobilisation system and setup protocol. Post-treatment orthogonal pair of kilovoltage X-ray images was acquired on the first three days of treatment. 106 sets of pre- and post-treatment kV X-ray images acquired over 53 fractions were analysed against the treatment planning DRR for calculation of intra-fraction movement. Results: Individual mean intra-fraction movement in all directions ranged from −1.8 to 1.1 mm. Population mean (median) intra-fraction movement in the x-, y-, and z-planes were −0.1 mm (0 mm), −0.3 mm (−0.3 mm) and −0.2 mm (−0.2 mm) respectively. Intra-fraction movement in all three dimensions, x-, y- and z-planes were considered statistically significant (p < 0.05). 7 out of 53 fractions (13.2%) were highlighted as the combined magnitude of the intra-fraction motion with the uncorrected pre-treatment setup errors had exceeded the boundaries of given margins. Conclusions: 3 mm-AL was not adequate to account for intra-fraction movement when the CTV–PTV margin was ⩽3 mm and should be excluded from the routine imaging protocol and daily image-guided radiotherapy should be employed. Adjusting the action-level to 2 mm would allow a more confident approach in delivery of the prescribed dose in head-and-neck IMRT cases

  6. Planning Target Margin Calculations for Prostate Radiotherapy Based on Intrafraction and Interfraction Motion Using Four Localization Methods

    International Nuclear Information System (INIS)

    Beltran, Chris; Herman, Michael G.; Davis, Brian J.

    2008-01-01

    Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the four daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction

  7. The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy

    International Nuclear Information System (INIS)

    Dawson, Laura A.; Brock, Kristy K.; Kazanjian, Sahira; Fitch, Dwight; McGinn, Cornelius J.; Lawrence, Theodore S.; Haken, Randall K. ten; Balter, James

    2001-01-01

    Purpose: To evaluate the intrafraction and interfraction reproducibility of liver immobilization using active breathing control (ABC). Methods and Materials: Patients with unresectable intrahepatic tumors who could comfortably hold their breath for at least 20 s were treated with focal liver radiation using ABC for liver immobilization. Fluoroscopy was used to measure any potential motion during ABC breath holds. Preceding each radiotherapy fraction, with the patient setup in the nominal treatment position using ABC, orthogonal radiographs were taken using room-mounted diagnostic X-ray tubes and a digital imager. The radiographs were compared to reference images using a 2D alignment tool. The treatment table was moved to produce acceptable setup, and repeat orthogonal verification images were obtained. The positions of the diaphragm and the liver (assessed by localization of implanted radiopaque intra-arterial microcoils) relative to the skeleton were subsequently analyzed. The intrafraction reproducibility (from repeat radiographs obtained within the time period of one fraction before treatment) and interfraction reproducibility (from comparisons of the first radiograph for each treatment with a reference radiograph) of the diaphragm and the hepatic microcoil positions relative to the skeleton with repeat breath holds using ABC were then measured. Caudal-cranial (CC), anterior-posterior (AP), and medial-lateral (ML) reproducibility of the hepatic microcoils relative to the skeleton were also determined from three-dimensional alignment of repeat CT scans obtained in the treatment position. Results: A total of 262 fractions of radiation were delivered using ABC breath holds in 8 patients. No motion of the diaphragm or hepatic microcoils was observed on fluoroscopy during ABC breath holds. From analyses of 158 sets of positioning radiographs, the average intrafraction CC reproducibility (σ) of the diaphragm and hepatic microcoil position relative to the skeleton

  8. Preparation and evaluation of 99mTc-EDDA/HYNIC-[Lys 3]-bombesin for imaging gastrin-releasing peptide receptor-positive tumours.

    Science.gov (United States)

    Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Rodriguez-Cortés, Jeanette; Pedraza-López, Martha; Ramírez-Iglesias, María Teresa

    2006-04-01

    Bombesin is a peptide that was initially isolated from frog skin and which belongs to a large group of neuropeptides with many biological functions. The human equivalent is gastrin-releasing peptide (GRP), whose receptors are over-expressed in a variety of malignant tumours. To prepare a HYNIC-[Lys 3]-bombesin analogue that could be easily labelled with 99mTc from lyophilized kit formulations and to evaluate its potential as an imaging agent for GRP receptor-positive tumours. HYNIC was conjugated to the epsilon-amino group of Lys 3 residue at the N-terminal region of bombesin via succinimidyl-N-Boc-HYNIC at pH 9.0. 99mTc labelling was performed by addition of sodium pertechnetate solution and 0.2 M phosphate buffer pH 7.0 to a lyophilized formulation. Stability studies were carried out by reversed phase HPLC and ITLC-SG analyses in serum and cysteine solutions. In-vitro internalization was tested using human prostate cancer PC-3 cells with blocked and non-blocked receptors. Biodistribution and tumour uptake were determined in PC-3 tumour-bearing nude mice. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin was obtained with radiochemical purities >93% and high specific activity ( approximately 0.1 GBq.nmol). Results of in-vitro studies demonstrated a high stability in serum and cysteine solutions, specific cell receptor binding and rapid internalization. Biodistribution data showed a rapid blood clearance, with predominantly renal excretion and specific binding towards GRP receptor-positive tissues such as pancreas and PC-3 tumours. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin obtained from lyophilized kit formulations has promising characteristics for the diagnosis of malignant tumours that over-express the GRP receptor.

  9. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 04: Assessment of intra-fraction motion during lung SABR VMAT using a custom abdominal compression device

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, Derek; Robinson, Mark; Araujo, Cynthia; Teke, Tony; Halperin, Ross; Petrik, David; Mou, Benjamin; Mohamed, Islam [BCCA - Centre for the Southern Interior (Canada)

    2016-08-15

    Purpose: Lung SABR patients are treated using Volumetrically Modulated Arc Therapy (VMAT), utilizing 2 arcs with Conebeam CT (CBCT) image-guidance prior to each arc. Intra-fraction imaging can prolong treatment time (up to 20%), and the aim of this study is to determine if it is necessary. Methods: We utilize an in-house abdominal compression device to minimize respiratory motion, 4DCT to define the ITV, a 5 mm PTV margin and a 2–3 mm PRV margin. We treated 23 patients with VMAT, fifteen were treated to 48 Gy in 4 fractions, while eight were treated with up to 60 Gy in 8 fractions. Intrafraction motion was assessed by the translational errors recorded for the second CBCT. Results: There was no significant difference (t-test, p=0.93) in the intra-fraction motion between the patients treated with 4 and 8 fractions, or between the absolute translations in each direction (ANOVA, p=0.17). All 124 intra-fraction CBCT images were analysed and 95% remained localized within the 5 mm PTV margin The mean magnitude of the vector displacement was 1.8 mm. Conclusions: For patients localized with an abdominal compression device, the intrafraction CBCT image may not be necessary, if it is only the tumor coverage that is of concern, as the patients are typically well within the 5 mm PTV margin. On the other hand, if there is a structure with a smaller PRV margin, an intrafraction CBCT is recommended to ensure that the dose limit for the organ at risk is not exceeded.

  10. Platelet-activating factor receptor (PAF-R)-dependent pathways control tumour growth and tumour response to chemotherapy

    International Nuclear Information System (INIS)

    Oliveira, Soraya I de; Andrade, Luciana NS; Onuchic, Ana C; Nonogaki, Sueli; Fernandes, Patrícia D; Pinheiro, Mônica C; Rohde, Ciro BS; Chammas, Roger; Jancar, Sonia

    2010-01-01

    Phagocytosis of apoptotic cells by macrophages induces a suppressor phenotype. Previous data from our group suggested that this occurs via Platelet-activating factor receptor (PAF-R)-mediated pathways. In the present study, we investigated the impact of apoptotic cell inoculation or induction by a chemotherapeutic agent (dacarbazine, DTIC) on tumour growth, microenvironmental parameters and survival, and the effect of treatment with a PAF-R antagonist (WEB2170). These studies were performed in murine tumours: Ehrlich Ascitis Tumour (EAT) and B16F10 melanoma. Tumour growth was assessed by direct counting of EAT cells in the ascitis or by measuring the volume of the solid tumour. Parameters of the tumour microenvironment, such as the frequency of cells expressing cyclo-oxygenase-2 (COX-2), caspase-3 and galectin-3, and microvascular density, were determined by immunohistochemistry. Levels of vascular endothelium growth factor (VEGF) and prostaglandin E2 (PGE2) were determined by ELISA, and levels of nitric oxide (NO) by Griess reaction. PAF-R expression was analysed by immunohistochemistry and flow cytometry. Inoculation of apoptotic cells before EAT implantation stimulated tumour growth. This effect was reversed by in vivo pre-treatment with WEB2170. This treatment also reduced tumour growth and modified the microenvironment by reducing PGE2, VEGF and NO production. In B16F10 melanoma, WEB2170 alone or in association with DTIC significantly reduced tumour volume. Survival of the tumour-bearing mice was not affected by WEB2170 treatment but was significantly improved by the combination of DTIC with WEB2170. Tumour microenvironment elements were among the targets of the combination therapy since the relative frequency of COX-2 and galectin-3 positive cells and the microvascular density within the tumour mass were significantly reduced by treatment with WEB2170 or DTIC alone or in combination. Antibodies to PAF-R stained the cells from inside the tumour, but not the

  11. Impact of sampling interval in training data acquisition on intrafractional predictive accuracy of indirect dynamic tumor-tracking radiotherapy.

    Science.gov (United States)

    Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Akimoto, Mami; Miyabe, Yuki; Yokota, Kenji; Matsuo, Yukinori; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-08-01

    To explore the effect of sampling interval of training data acquisition on the intrafractional prediction error of surrogate signal-based dynamic tumor-tracking using a gimbal-mounted linac. Twenty pairs of respiratory motions were acquired from 20 patients (ten lung, five liver, and five pancreatic cancer patients) who underwent dynamic tumor-tracking with the Vero4DRT. First, respiratory motions were acquired as training data for an initial construction of the prediction model before the irradiation. Next, additional respiratory motions were acquired for an update of the prediction model due to the change of the respiratory pattern during the irradiation. The time elapsed prior to the second acquisition of the respiratory motion was 12.6 ± 3.1 min. A four-axis moving phantom reproduced patients' three dimensional (3D) target motions and one dimensional surrogate motions. To predict the future internal target motion from the external surrogate motion, prediction models were constructed by minimizing residual prediction errors for training data acquired at 80 and 320 ms sampling intervals for 20 s, and at 500, 1,000, and 2,000 ms sampling intervals for 60 s using orthogonal kV x-ray imaging systems. The accuracies of prediction models trained with various sampling intervals were estimated based on training data with each sampling interval during the training process. The intrafractional prediction errors for various prediction models were then calculated on intrafractional monitoring images taken for 30 s at the constant sampling interval of a 500 ms fairly to evaluate the prediction accuracy for the same motion pattern. In addition, the first respiratory motion was used for the training and the second respiratory motion was used for the evaluation of the intrafractional prediction errors for the changed respiratory motion to evaluate the robustness of the prediction models. The training error of the prediction model was 1.7 ± 0.7 mm in 3D for all sampling

  12. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J [University of North Carolina, Chapel Hill, NC (United States); Chao, E [Accuray Incorporated, Madison, WI (United States)

    2016-06-15

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  13. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    International Nuclear Information System (INIS)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J; Chao, E

    2016-01-01

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  14. Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Yang, E-mail: Yang.Sheng@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Li, Taoran [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Lee, W. Robert [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Yin, Fang-Fang; Wu, Q. Jackie [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States)

    2017-06-01

    Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold

  15. Neurohypophysis granular cell tumours. Upon neurohypophysis rare tumours; Les tumeurs a cellules granuleuses. Des tumeurs rares de la neurohypophyse

    Energy Technology Data Exchange (ETDEWEB)

    Barrande, G.; Kujas, M.; Gancel, A.; Turpin, G.; Bruckert, E.; Kuhn, J.M.; Luton, J.P. [Hopital Cochin, 75 - Paris (France)

    1995-10-01

    Granular cell tumours of neurohypophysis are rare. These tumours are more often encountered as incidental autopsy findings seen in up to 17 % of unselected adult autopsy cases. There are few reports of para-sellar granular cell tumours large enough to cause symptoms. We present three cases of neurohypophysis granular cell tumour and a review of the literature. In one patient, the asymptomatic granular cell tumour was incidentally discovered at surgical removal of a corticotrophic micro-adenoma. The remaining 2 patients had a symptomatic tumour which caused neurological symptoms such as visual disturbance and headaches and endocrine disorders such as hypopituitarism or hyper-prolactinaemia. In these 2 cases, computerized tomography showed a well-circumscribed, contrast-enhanced, intra-sellar and supra-sellar mass. Magnetic resonance imaging demonstrated an isointense gadolinium-enhanced mass in T1-weighted-images. Trans-sphenoidal partial resection was performed and histology was interpreted as a granular cell tumour. The immunohistochemical study was positive for glial fibrillary acidic protein (GEAP) and neuron specific enolase (NSE) in 1 of the 2 tumours and positive for S100 protein and vimentin in both tumours but negative for CD68. The histogenesis of neurohypophysis granular cell tumours is still controversial but ultrastructural and immunohistochemical studies support the theory that may arise from pituicytes, the glial cells of neurohypophysis. Management of these benign, slow growing, tumours is based mainly on neurosurgical resection. Data from the literature do not support a beneficial effect of post operative radiation therapy on postoperative recurrences. (authors). 23 refs., 4 figs., 1 tab.

  16. Nuclear translocation of β-catenin and decreased expression of epithelial cadherin in human papillomavirus-positive tonsillar cancer: an early event in human papillomavirus-related tumour progression?

    Science.gov (United States)

    Stenner, Markus; Yosef, Basima; Huebbers, Christian U; Preuss, Simon F; Dienes, Hans-Peter; Speel, Ernst-Jan M; Odenthal, Margarete; Klussmann, Jens P

    2011-06-01

    High-risk human papillomaviruses (HPVs) constitute an important risk factor for tonsillar cancer. This study describes changes in cell adhesion molecules during metastasis of HPV-related and HPV-unrelated tonsillar carcinomas. We examined 48 primary tonsillar carcinoma samples (25 HPV-16 DNA-positive, 23 HPV-16 DNA-negative) and their respective lymph node metastases for their HPV status and for the expression of p16, epithelial cadherin (E-cadherin), β-catenin, and vimentin. A positive HPV-specific polymerase chain reaction finding correlated significantly with p16 overexpression in both primary tumours and their metastases (P<0.0001 for both). In HPV-unrelated carcinomas, the expression of E-cadherin was significantly lower in metastases than in primary tumours (P<0.001). In contrast, the expression of nuclear β-catenin was significantly higher in metastases than in primary tumours (P=0.016). In HPV-related carcinomas, nuclear localization of β-catenin expression was already apparent in primary tumours (P=0.030). The expression of vimentin significantly correlated with the grading of the primary tumour (P=0.021). Our data indicate that the down-regulation of E-cadherin and the up-regulation of nuclear β-catenin expression might be crucial steps during tumour progression of tonsillar carcinomas, being already present in primary tumours in HPV-driven carcinomas, but becoming apparent in HPV-unrelated tumours later in the process of metastasis. © 2011 Blackwell Publishing Limited.

  17. Positional uncertainties on sterotactic radiosurgery for spinal metastases using volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seung Hyuck; Park, So Yeon; Kim, Jin Ho; Kim, Jung In; Park, Jong Min [Dept. of Nuclear Engineering, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-04-15

    For spinal metastatic cancers, stereotactic radiosurgery (SRS) plays a key role in tumor control and pain relief by delivering high doses to the lesions. Dose limiting factor to this treatment is spinal cord tolerance. Radiation-induced spinal cord injury, although uncommon, can result in paralysis, sensory deficits, or Brown-Sequard syndrome. Hence, various efforts are necessary to eliminate the risk of radiation myelitis, while keeping adequate dose delivery to target volumes. The Body-FIX system is employed to immobilize the patients. Despite these efforts, residual setup errors and intrafraction motions can cause dosimetric uncertainties. In this context, this study aimed to investigate residual setup errors and intrafraction motions in SRS of spinal metastasis. With appropriate immobilization and 4 DoF corrections, an 1-mm PTV margin is adequate for CTV coverage, accounting for both residual errors. Even with an perfect 6 DoF correction, at least 1-mm PTV margin is still necessary to address intrafraction motions. Given the fixed relative position between the spinal cord and vertebrae, it is assumed that the spinal cord is subject to a same degree of positional uncertainty.

  18. Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks

    International Nuclear Information System (INIS)

    Velec, Michael; Waldron, John N.; O'Sullivan, Brian; Bayley, Andrew; Cummings, Bernard; Kim, John J.; Ringash, Jolie; Breen, Stephen L.; Lockwood, Gina A.; Dawson, Laura A.

    2010-01-01

    Purpose: To prospectively compare setup error in standard thermoplastic masks and skin-sparing masks (SSMs) modified with low neck cutouts for head-and-neck intensity-modulated radiation therapy (IMRT) patients. Methods and Materials: Twenty head-and-neck IMRT patients were randomized to be treated in a standard mask (SM) or SSM. Cone-beam computed tomography (CBCT) scans, acquired daily after both initial setup and any repositioning, were used for initial and residual interfraction evaluation, respectively. Weekly, post-IMRT CBCT scans were acquired for intrafraction setup evaluation. The population random (σ) and systematic (Σ) errors were compared for SMs and SSMs. Skin toxicity was recorded weekly by use of Radiation Therapy Oncology Group criteria. Results: We evaluated 762 CBCT scans in 11 patients randomized to the SM and 9 to the SSM. Initial interfraction σ was 1.6 mm or less or 1.1 deg. or less for SM and 2.0 mm or less and 0.8 deg. for SSM. Initial interfraction Σ was 1.0 mm or less or 1.4 deg. or less for SM and 1.1 mm or less or 0.9 deg. or less for SSM. These errors were reduced before IMRT with CBCT image guidance with no significant differences in residual interfraction or intrafraction uncertainties between SMs and SSMs. Intrafraction σ and Σ were less than 1 mm and less than 1 deg. for both masks. Less severe skin reactions were observed in the cutout regions of the SSM compared with non-cutout regions. Conclusions: Interfraction and intrafraction setup error is not significantly different for SSMs and conventional masks in head-and-neck radiation therapy. Mask cutouts should be considered for these patients in an effort to reduce skin toxicity.

  19. Nonrandom Intrafraction Target Motions and General Strategy for Correction of Spine Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Ma Lijun; Sahgal, Arjun; Hossain, Sabbir; Chuang, Cynthia; Descovich, Martina; Huang, Kim; Gottschalk, Alex; Larson, David A.

    2009-01-01

    Purpose: To characterize nonrandom intrafraction target motions for spine stereotactic body radiotherapy and to develop a method of correction via image guidance. The dependence of target motions, as well as the effectiveness of the correction strategy for lesions of different locations within the spine, was analyzed. Methods and Materials: Intrafraction target motions for 64 targets in 64 patients treated with a total of 233 fractions were analyzed. Based on the target location, the cases were divided into three groups, i.e., cervical (n = 20 patients), thoracic (n = 20 patients), or lumbar-sacrum (n = 24 patients) lesions. For each case, time-lag autocorrelation analysis was performed for each degree of freedom of motion that included both translations (x, y, and z shifts) and rotations (roll, yaw, and pitch). A general correction strategy based on periodic interventions was derived to determine the time interval required between two adjacent interventions, to overcome the patient-specific target motions. Results: Nonrandom target motions were detected for 100% of cases regardless of target locations. Cervical spine targets were found to possess the highest incidence of nonrandom target motion compared with thoracic and lumbar-sacral lesions (p < 0.001). The average time needed to maintain the target motion to within 1 mm of translation or 1 deg. of rotational deviation was 5.5 min, 5.9 min, and 7.1 min for cervical, thoracic, and lumbar-sacrum locations, respectively (at 95% confidence level). Conclusions: A high incidence of nonrandom intrafraction target motions was found for spine stereotactic body radiotherapy treatments. Periodic interventions at approximately every 5 minutes or less were needed to overcome such motions.

  20. Radiological diagnosis of liver tumours

    International Nuclear Information System (INIS)

    Lundstedt, C.

    1987-01-01

    Sixty patients treated with an intra-arterial cytostatic drug for metastases from colo-rectal carcinoma were evaluated with angiography to determine prognostic parameters. The extent of tumour in the liver and an unchanged or diminished tumour volume following treatment, as demonstrated with angiography, were associated with significant prolongation of survival. Patients who developed occlusion of the hepatic artery or of branches of the portal vein, also survived longer. 189 patients examined with angiography, 161 with computed tomography (CT), 95 with computed tomographic arteriography (CTA) and 71 with ultrasound (US) were subjected to liver evaluation at laparotomy consisting of inspection and palpation. The result of this surgical liver evaluation was for the purpose of the study regarded as completely accurate and was used to assess the accuracy of the different radiological methods. The location of tumour in the liver lobes or segments was analysed, with a separate evaluation of the right and left liver lobes. The rate of detection of individual tumour nodules was also determined. Angiography detected 55% of liver areas affected by tumour and 47% of individual tumour nodules. CT detected 83% of liver lobes or segments containing tumour, and 70% of the tumour nodules. US detected 69% of the portions of liver holding tumour, and also 69% of the tumour nodules. CTA detected 85% of tumours areas and 74% of separate tumour nodules. Some lesions detected with CT were not seen with CTA and vice versa. More false-positive results were recorded with CTA than with CT using intravenous contrast enhancement. (orig.)

  1. Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion

    International Nuclear Information System (INIS)

    Kissick, Michael W.; Boswell, Sarah A.; Jeraj, Robert; Mackie, T. Rockwell

    2005-01-01

    The interplay between a constant scan speed and intrafraction oscillatory motion produces interesting fluence intensity modulations along the axis of motion that are sensitive to the motion function, as originally shown in a classic paper by Yu et al. [Phys. Med. Biol. 43, 91-104 (1998)]. The fluence intensity profiles are explored in this note for an intuitive understanding, then compared with Yu et al., and finally further explored for the effects of low scan speed and random components of both intrafraction and interfraction motion. At slow scan speeds typical of helical tomotherapy, these fluence intensity modulations are only a few percent. With the addition of only a small amount of cycle-to-cycle randomness in frequency and amplitude, the fluence intensity profiles change dramatically. It is further shown that after a typical 30-fraction treatment, the sensitivities displayed in the single fraction fluence intensity profiles greatly diminish

  2. [Gastric mesenchymal tumours (GIST)].

    Science.gov (United States)

    Spivach, Arrigo; Fezzi, Margherita; Sartori, Alberto; Belgrano, Manuel; Rimondini, Alessandra; Cuttin-Zernich, Roberto; Covab, Maria Assunta; Bonifacio, Daniela; Buri, Luigi; Pagani, Carlo; Zanconati, Fabrizio

    2008-01-01

    The incidence of gastrointestinal stromal tumours (GIST) has increased in recent years. A number of authors have attempted to define the actual nature of these tumours. Immunohistochemistry highlighting the positivity of tyrosine-kinase (CD117/c-Kit) has revealed the difference between gastrointestinal stromal tumours and other mesenchymal tumours and, therefore, the possibility of medical rather than surgical therapy. We retrospectively reviewed 19 patients affected by primary gastric GIST, who underwent surgery in recent years with subsequent follow-up. Gastroscopy and gastrointestinal tract radiography were used not only to obtain the diagnosis but also to establish the size, density, contours, ulceration, regional lymphadenopathy, mesenteric infiltration and the presence of metastases. The aim of this study was to evaluate the roles of endoscopy and radiology in this pathology and the advantages and limitations of each individual technique.

  3. 99mTc-labelled HYNIC-minigastrin with reduced kidney uptake for targeting of CCK-2 receptor-positive tumours

    International Nuclear Information System (INIS)

    Guggenberg, E. von; Gabriel, M.; Virgolini, I.J.; Decristoforo, C.; Dietrich, H.; Skvortsova, I.

    2007-01-01

    Different attempts have been made to develop a suitable radioligand for targeting CCK-2 receptors in vivo, for staging of medullary thyroid carcinoma (MTC) and other receptor-expressing tumours. After initial successful clinical studies with [DTPA 0 ,DGlu 1 ]minigastrin (DTPA-MG0) radiolabelled with 111 In and 90 Y, our group developed a 99m Tc-labelled radioligand, based on HYNIC-MG0. A major drawback observed with these derivatives is their high uptake by the kidneys. In this study we describe the preclinical evaluation of the optimised shortened peptide analogue, [HYNIC 0 ,DGlu 1 ,desGlu 2-6 ]minigastrin (HYNIC-MG11). 99m Tc labelling of HYNIC-MG11 was performed using tricine and EDDA as coligands. Stability experiments were carried out by reversed phase HPLC analysis in PBS, PBS/cysteine and plasma as well as rat liver and kidney homogenates. Receptor binding and cell uptake experiments were performed using AR4-2J rat pancreatic tumour cells. Animal biodistribution was studied in AR4-2J tumour-bearing nude mice. Radiolabelling was performed at high specific activities and radiochemical purity was >90%. 99m Tc-EDDA-HYNIC-MG11 showed high affinity for the CCK-2 receptor and cell internalisation comparable to that of 99m Tc-EDDA-HYNIC-MG0. Despite high stability in solution, a low metabolic stability in rat tissue homogenates was found. In a nude mouse tumour model, very low unspecific retention in most organs, rapid renal excretion with reduced renal retention and high tumour uptake were observed. 99m Tc-EDDA-HYNIC-MG11 shows advantages over 99m Tc-EDDA-HYNIC-MG0 in terms of lower kidney retention with unchanged uptake in tumours and CCK-2 receptor-positive tissue. However, the lower metabolic stability and impurities formed in the labelling process still leave room for further improvement. (orig.)

  4. Daily Prostate Volume and Position Monitoring Using Implanted Gold Markers and On-Board Imaging during Radiotherapy

    Directory of Open Access Journals (Sweden)

    Linda Kašaová

    2011-01-01

    Full Text Available Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy. Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

  5. Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

    Energy Technology Data Exchange (ETDEWEB)

    Both, Stefan, E-mail: Stefan.Both@uphs.upenn.edu [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States); Wang, Ken Kang-Hsin; Plastaras, John P.; Deville, Curtiland; Bar Ad, Voika; Tochner, Zelig; Vapiwala, Neha [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)

    2011-12-01

    Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

  6. Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy

    International Nuclear Information System (INIS)

    Stuetzer, Kristin

    2014-01-01

    Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumor conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumor volume to reach higher tumor control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumor entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumor sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion-compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two β + -activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the

  7. SU-E-T-41: Analysis of GI Dose Variability Due to Intrafraction Setup Variance

    International Nuclear Information System (INIS)

    Phillips, J; Wolfgang, J

    2014-01-01

    Purpose: Proton SBRT (stereotactic body radiation therapy) can be an effective modality for treatment of gastrointestinal tumors, but limited in practice due to sensitivity with respect to variation in the RPL (radiological path length). Small, intrafractional shifts in patient anatomy can lead to significant changes in the dose distribution. This study describes a tool designed to visualize uncertainties in radiological depth in patient CT's and aid in treatment plan design. Methods: This project utilizes the Shadie toolkit, a GPU-based framework that allows for real-time interactive calculations for volume visualization. Current SBRT simulation practice consists of a serial CT acquisition for the assessment of inter- and intra-fractional motion utilizing patient specific immobilization systems. Shadie was used to visualize potential uncertainties, including RPL variance and changes in gastric content. Input for this procedure consisted of two patient CT sets, contours of the desired organ, and a pre-calculated dose. In this study, we performed rigid registrations between sets of 4DCT's obtained from a patient with varying setup conditions. Custom visualizations are written by the user in Shadie, permitting one to create color-coded displays derived from a calculation along each ray. Results: Serial CT data acquired on subsequent days was analyzed for variation in RPB and gastric content. Specific shaders were created to visualize clinically relevant features, including RPL (radiological path length) integrated up to organs of interest. Using pre-calculated dose distributions and utilizing segmentation masks as additional input allowed us to further refine the display output from Shadie and create tools suitable for clinical usage. Conclusion: We have demonstrated a method to visualize potential uncertainty for intrafractional proton radiotherapy. We believe this software could prove a useful tool to guide those looking to design treatment plans least

  8. Analysis of intra-fraction prostate motion and derivation of duration-dependent margins for radiotherapy using real-time 4D ultrasound

    Directory of Open Access Journals (Sweden)

    Eric Pei Ping Pang

    2018-01-01

    Full Text Available Background and purpose: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. Material and methods: A four-dimension (4D transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT treatment (an additional seven minutes. A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. Results: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm and posterior (−0.2 versus −0.4 mm directions respectively (p ≪ 0.01. An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior; 0.8 mm (left/right, 1.7 mm/2.9 mm (anterior/posterior for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior, 1.5 mm (left/right, 2.8 mm/4.8 mm (anterior/posterior for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1–1.9 mm anteriorly/posteriorly. Conclusions: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should

  9. TU-AB-303-06: Does Online Adaptive Radiation Therapy Mean Zero Margin for Intermediate-Risk Prostate Cancer? An Intra-Fractional Seminal Vesicles Motion Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Y; Li, T; Lee, W; Yin, F; Wu, Q [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To provide benchmark for seminal vesicles (SVs) margin selection to account for intra-fractional motion; and to investigate the effectiveness of two motion surrogates in predicting intra-fractional SV underdosage. Methods: 9 prostate SBRT patients were studied; each has five pairs of pre-treatment and post-treatment cone-beam CTs (CBCTs). Each pair of CBCTs was registered based on fiducial markers in the prostate. To provide “ground truth” for coverage evaluation, all pre-treatment SVs were expanded with isotropic margin of 1,2,3,5 and 8mm, and their overlap with post-treatment SVs were used to quantify intra-fractional coverage. Two commonly used motion surrogates, the center-of-mass (COM) and the border of contour (the most distal points in SI/AP/LR directions) were evaluated using Receiver-Operating Characteristic (ROC) analyses for predicting SV underdosage due to intra-fractional motion. Action threshold of determining underdosage for each surrogate was calculated by selecting the optimal balancing between sensitivity and specificity. For comparison, margin for each surrogate was also calculated based on traditional margin recipe. Results: 90% post-treatment SV coverage can be achieved in 47%, 82%, 91%, 98% and 98% fractions for 1,2,3,5 and 8mm margins. 3mm margin ensured the 90% intra-fractional SV coverage in 90% fractions when prostate was aligned. The ROC analysis indicated the AUC for COM and border were 0.88 and 0.72. The underdosage threshold was 2.9mm for COM and 4.1mm for border. The Van Herk’s margin recipe recommended 0.5, 0 and 1.8mm margin in LR, AP and SI direction based on COM and for border, the corresponding margin was 2.1, 4.5 and 3mm. Conclusion: 3mm isotropic margin is the minimum required to mitigate the intra-fractional SV motion when prostate is aligned. ROC analysis reveals that both COM and border are acceptable predictors for SV underdosage with 2.9mm and 4.1mm action threshold. Traditional margin calculation is less

  10. TU-AB-303-06: Does Online Adaptive Radiation Therapy Mean Zero Margin for Intermediate-Risk Prostate Cancer? An Intra-Fractional Seminal Vesicles Motion Analysis

    International Nuclear Information System (INIS)

    Sheng, Y; Li, T; Lee, W; Yin, F; Wu, Q

    2015-01-01

    Purpose: To provide benchmark for seminal vesicles (SVs) margin selection to account for intra-fractional motion; and to investigate the effectiveness of two motion surrogates in predicting intra-fractional SV underdosage. Methods: 9 prostate SBRT patients were studied; each has five pairs of pre-treatment and post-treatment cone-beam CTs (CBCTs). Each pair of CBCTs was registered based on fiducial markers in the prostate. To provide “ground truth” for coverage evaluation, all pre-treatment SVs were expanded with isotropic margin of 1,2,3,5 and 8mm, and their overlap with post-treatment SVs were used to quantify intra-fractional coverage. Two commonly used motion surrogates, the center-of-mass (COM) and the border of contour (the most distal points in SI/AP/LR directions) were evaluated using Receiver-Operating Characteristic (ROC) analyses for predicting SV underdosage due to intra-fractional motion. Action threshold of determining underdosage for each surrogate was calculated by selecting the optimal balancing between sensitivity and specificity. For comparison, margin for each surrogate was also calculated based on traditional margin recipe. Results: 90% post-treatment SV coverage can be achieved in 47%, 82%, 91%, 98% and 98% fractions for 1,2,3,5 and 8mm margins. 3mm margin ensured the 90% intra-fractional SV coverage in 90% fractions when prostate was aligned. The ROC analysis indicated the AUC for COM and border were 0.88 and 0.72. The underdosage threshold was 2.9mm for COM and 4.1mm for border. The Van Herk’s margin recipe recommended 0.5, 0 and 1.8mm margin in LR, AP and SI direction based on COM and for border, the corresponding margin was 2.1, 4.5 and 3mm. Conclusion: 3mm isotropic margin is the minimum required to mitigate the intra-fractional SV motion when prostate is aligned. ROC analysis reveals that both COM and border are acceptable predictors for SV underdosage with 2.9mm and 4.1mm action threshold. Traditional margin calculation is less

  11. Intra-fraction prostate displacement in radiotherapy estimated from pre- and post-treatment imaging of patients with implanted fiducial markers

    International Nuclear Information System (INIS)

    Kron, Tomas; Thomas, Jessica; Fox, Chris; Thompson, Ann; Owen, Rebecca; Herschtal, Alan; Haworth, Annette; Tai, Keen-Hun; Foroudi, Farshad

    2010-01-01

    Purpose: To determine intra-fraction displacement of the prostate gland from imaging pre- and post-radiotherapy delivery of prostate cancer patients with three implanted fiducial markers. Methods and materials: Data were collected from 184 patients who had two orthogonal X-rays pre- and post-delivery on at least 20 occasions using a Varian On Board kV Imaging system. A total of 5778 image pairs covering time intervals between 3 and 30 min between pre- and post-imaging were evaluated for intra-fraction prostate displacement. Results: The mean three dimensional vector shift between images was 1.7 mm ranging from 0 to 25 mm. No preferential direction of displacement was found; however, there was an increase of prostate displacement with time between images. There was a large variation in typical shifts between patients (range 1 ± 1 to 6 ± 2 mm) with no apparent trends throughout the treatment course. Images acquired in the first five fractions of treatment could be used to predict displacement patterns for individual patients. Conclusion: Intra-fraction motion of the prostate gland appears to be a limiting factor when considering margins for radiotherapy. Given the variation between patients, a uniform set of margins for all patients may not be satisfactory when high target doses are to be delivered.

  12. Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images

    International Nuclear Information System (INIS)

    Li Ruijiang; Mok, Edward; Han, Bin; Koong, Albert; Xing Lei

    2012-01-01

    Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend

  13. Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Yuanyuan; O’Brien, Ricky T.; Shieh, Chun-Chien; Keall, Paul J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, University of Sydney, NSW 2006 (Australia); Booth, Jeremy T. [Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065 (Australia)

    2014-06-15

    Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first

  14. Life history, immunity, Peto's paradox and tumours in birds.

    Science.gov (United States)

    Møller, A P; Erritzøe, J; Soler, J J

    2017-05-01

    Cancer and tumours may evolve in response to life-history trade-offs between growth and duration of development on one hand, and between growth and maintenance of immune function on the other. Here, we tested whether (i) bird species with slow developmental rates for their body size experience low incidence of tumours because slow development allows for detection of rapid proliferation of cell lineages. We also test whether (ii) species with stronger immune response during development are more efficient at detecting tumour cells and hence suffer lower incidence of tumours. Finally, we tested Peto's paradox, that there is a positive relationship between tumour incidence and body mass. We used information on developmental rates and body mass from the literature and of tumour incidence (8468 birds) and size of the bursa of Fabricius for 7659 birds brought to a taxidermist in Denmark. We found evidence of the expected negative relationship between incidence of tumours and developmental rates and immunity after controlling for the positive association between tumour incidence and body size. These results suggest that evolution has modified the incidence of tumours in response to life history and that Peto's paradox may be explained by covariation between body mass, developmental rates and immunity. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.

  15. The random walk model of intrafraction movement

    International Nuclear Information System (INIS)

    Ballhausen, H; Reiner, M; Kantz, S; Belka, C; Söhn, M

    2013-01-01

    The purpose of this paper is to understand intrafraction movement as a stochastic process driven by random external forces. The hypothetically proposed three-dimensional random walk model has significant impact on optimal PTV margins and offers a quantitatively correct explanation of experimental findings. Properties of the random walk are calculated from first principles, in particular fraction-average population density distributions for displacements along the principal axes. When substituted into the established optimal margin recipes these fraction-average distributions yield safety margins about 30% smaller as compared to the suggested values from end-of-fraction Gaussian fits. Stylized facts of a random walk are identified in clinical data, such as the increase of the standard deviation of displacements with the square root of time. Least squares errors in the comparison to experimental results are reduced by about 50% when accounting for non-Gaussian corrections from the random walk model. (paper)

  16. The random walk model of intrafraction movement.

    Science.gov (United States)

    Ballhausen, H; Reiner, M; Kantz, S; Belka, C; Söhn, M

    2013-04-07

    The purpose of this paper is to understand intrafraction movement as a stochastic process driven by random external forces. The hypothetically proposed three-dimensional random walk model has significant impact on optimal PTV margins and offers a quantitatively correct explanation of experimental findings. Properties of the random walk are calculated from first principles, in particular fraction-average population density distributions for displacements along the principal axes. When substituted into the established optimal margin recipes these fraction-average distributions yield safety margins about 30% smaller as compared to the suggested values from end-of-fraction gaussian fits. Stylized facts of a random walk are identified in clinical data, such as the increase of the standard deviation of displacements with the square root of time. Least squares errors in the comparison to experimental results are reduced by about 50% when accounting for non-gaussian corrections from the random walk model.

  17. Intrafractional setup errors in patients undergoing non-invasive fixation using an immobilization system during hypofractionated stereotactic radiotherapy for lung tumors

    International Nuclear Information System (INIS)

    Watanabe, Meguru; Onishi, Hiroshi; Kuriyama, Kengo

    2013-01-01

    Intrafractional setup errors during hypofractionated stereotactic radiotherapy (SRT) were investigated on the patient under voluntary breath-holding conditions with non-invasive immobilization on the CT-linac treatment table. A total of 30 patients with primary and metastatic lung tumors were treated with the hypofractionated SRT with a total dose of 48-60 Gy with four treatment fractions. The patient was placed supine and stabilized on the table with non-invasive patient fixation. Intrafractional setup errors in Right/Left (R.L.), Posterior/Anterior (P.A.), and Inferior/Superior (I.S.) dimensions were analyzed with pre- and post-irradiation CT images. The means and one standard deviation of the intrafractional errors were 0.9±0.7 mm (R.L.), 0.9±0.7 mm (P.A.) and 0.5±1.0 mm (I.S.). Setup errors in each session of the treatment demonstrated no statistically significant difference in the mean value between any two sessions. The frequency within 3 mm displacement was 98% in R.L., 98% in P.A. and 97% in I.S. directions. SRT under the non-invasive patient fixation immobilization system with a comparatively loose vacuum pillow demonstrated satisfactory reproducibility of minimal setup errors with voluntary breath-holding conditions that required a small internal margin. (author)

  18. {sup 99m}Tc-HYNIC-spermine for imaging polyamine transport system-positive tumours: preclinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pesnel, Sabrina [Institut de Recherche Pierre Fabre, Centre de Recherche en Oncologie Experimentale, Toulouse (France); UPS TAAM - CIPA, CNRS, Orleans (France); Guminski, Yves; Imbert, Thierry [Institut de Recherche Pierre Fabre, Division de Chimie Medicinale III, Castres (France); Pillon, Arnaud; Guilbaud, Nicolas; Kruczynski, Anna; Bailly, Christian [Institut de Recherche Pierre Fabre, Centre de Recherche en Oncologie Experimentale, Toulouse (France); Lerondel, Stephanie [UPS TAAM - CIPA, CNRS, Orleans (France); Le Pape, Alain [UPS TAAM - CIPA, CNRS, Orleans (France); Universite Francois Rabelais, INSERM U618, Tours (France)

    2011-10-15

    F14512 exploiting the polyamine transport system (PTS) for tumour cell delivery has been described as a potent antitumour agent. The optimal use of this compound will require a probe to identify tumour cells expressing a highly active PTS that might be more sensitive to the treatment. The aim of this study was to design and characterize a scintigraphic probe to evaluate its uptake in cancer cells expressing the PTS. Three polyamines coupled to a hydrazinonicotinamide (HYNIC) moiety were synthesized and labelled with {sup 99m}Tc. Their radiochemical purity was determined by HPLC. The plasma stability of the {sup 99m}Tc-HYNIC-spermine probe and its capacity to accumulate into PTS-active cells were also evaluated. In vitro internalization was tested using murine melanoma B16/F10 cells and human lung carcinoma A549 cells. Biodistribution was determined in healthy mice and tumour uptake was studied in B16/F10 tumour-bearing mice. A HL-60-Luc human leukaemia model was used to confront single photon emission computed tomography (SPECT) images obtained with the {sup 99m}Tc-labelled probe with those obtained by bioluminescence. The {sup 99m}Tc-HYNIC-spermine probe was selected for its capacity to accumulate into PTS-active cells and its stability in plasma. In vitro studies demonstrated that the probe was internalized in the cells via the PTS. In vivo measurements indicated a tumour to muscle scintigraphic ratio of 7.9{+-}2.8. The combined bioluminescence and scintigraphic analyses with the leukaemia model demonstrated that the spermine conjugate accumulates into the tumour cells. The {sup 99m}Tc-HYNIC-spermine scintigraphic probe is potentially useful to characterize the PTS activity of tumours. Additional work is needed to determine if this novel conjugate may be useful to analyse the PTS status of patients with solid tumours. (orig.)

  19. Carcinoid tumour of the middle ear

    LENUS (Irish Health Repository)

    Baig, Salman

    2012-09-01

    A case of middle ear mass in a young female from Ireland is described, who presented with left ear hearing loss and intermittent bloody discharge from the same ear. Examination under microscope revealed occlusive polyp in the left ear and a biopsy had been taken under general anaesthesia. Histopathology report described an adenoma \\/ carcinoid tumour of the middle ear confirmed by positive immunohistochemical staining. CT temporal bones revealed the extension of the disease. The patient underwent left tympanotomy and excision of the tumour. In general, these tumours are regarded as benign but may be mistaken for adenocarcinomas because of their histological heterogenecity.

  20. Histomorphological and immunohistochemical characterization of 172 cutaneous round cell tumours in dogs

    Directory of Open Access Journals (Sweden)

    Marina Rios Araújo

    2012-08-01

    Full Text Available This paper describes the use of a panel of antibodies (CD117, CD3, CD79a, CD45, cytokeratin, vimentin and E-cadherin on formalin-fixed, paraffin-embedded sections of canine cutaneous round cell tumours. Neoplastic tumours were diagnosed by histology and histochemical stains and included 107 mast cell tumours, 31 cutaneous histiocytomas, two localized histiocytic sarcomas, 21 cutaneous lymphomas, three plasma cell tumours, one transmissible venereal tumour and seven unclassified round cell tumours. The histologic diagnosis was modified in 39.5% of the total 172 neoplasms. The staining for CD45 and Ecadherin were variable, and therefore, the final diagnoses of cutaneous histiocytoma and localized histiocytic sarcoma were made based on histology in association with negative results for CD3, CD79a, CD117 and cytokeratin. The cellular origin of unclassified round cell tumours was defined in all cases. Cutaneous B-cell lymphoma and plasma cell tumours were CD79a-positive and could be distinguished from each other by the morphological characteristics. Mast cell tumours and T cell lymphoma were CD117 and CD3 positive, respectively. The positive staining for vimentin and the negative staining for CD3, CD79a, CD117 and cytokeratin favoured the diagnosis of transmissible venereal tumours. Thus, the final diagnosis of cutaneous round cell tumours should be based on the interpretation of immunohistochemical results together with the cellular morphology observed by histology. Therefore, more studies to optimize the specific markers in formalin-fixed, paraffinembedded tissues (especially for histiocytes are required for definitive diagnosis of round cell tumours in dogs.

  1. Effect of intra-fraction motion on the accumulated dose for free-breathing MR-guided stereotactic body radiation therapy of renal-cell carcinoma

    Science.gov (United States)

    Stemkens, Bjorn; Glitzner, Markus; Kontaxis, Charis; de Senneville, Baudouin Denis; Prins, Fieke M.; Crijns, Sjoerd P. M.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.; Tijssen, Rob H. N.

    2017-09-01

    Stereotactic body radiation therapy (SBRT) has shown great promise in increasing local control rates for renal-cell carcinoma (RCC). Characterized by steep dose gradients and high fraction doses, these hypo-fractionated treatments are, however, prone to dosimetric errors as a result of variations in intra-fraction respiratory-induced motion, such as drifts and amplitude alterations. This may lead to significant variations in the deposited dose. This study aims to develop a method for calculating the accumulated dose for MRI-guided SBRT of RCC in the presence of intra-fraction respiratory variations and determine the effect of such variations on the deposited dose. For this, RCC SBRT treatments were simulated while the underlying anatomy was moving, based on motion information from three motion models with increasing complexity: (1) STATIC, in which static anatomy was assumed, (2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, and (3) PCA, a method that generates 3D volumes with sufficient spatio-temporal resolution to capture respiration and intra-fraction variations. Five RCC patients and two volunteers were included and treatments delivery was simulated, using motion derived from subject-specific MR imaging. Motion was most accurately estimated using the PCA method with root-mean-squared errors of 2.7, 2.4, 1.0 mm for STATIC, AVG-RESP and PCA, respectively. The heterogeneous patient group demonstrated relatively large dosimetric differences between the STATIC and AVG-RESP, and the PCA reconstructed dose maps, with hotspots up to 40% of the D99 and an underdosed GTV in three out of the five patients. This shows the potential importance of including intra-fraction motion variations in dose calculations.

  2. Gene expression of circulating tumour cells and its correlation with tumour stage in breast cancer patients

    Directory of Open Access Journals (Sweden)

    Bölke E

    2009-09-01

    Full Text Available Abstract Background Breast cancer (BC represents one of the leading causes of cancer related deaths worldwide. New tools for diagnostic staging and therapeutic monitoring are needed to improve individualized therapies and improve clinical outcome. The analyses of circulating tumour cells may provide important prognostic information in the clinical setting. Materials and methods Circulating tumour cells (CTC of 63 BC patients were isolated from peripheral blood (PB through immunomagnetic separation. Subsequently, RT-PCR or mPCR for the genes ga733.2, muc-1, c-erbB2, mgb-1, spdef and c-erbB2 were performed. Subsequently, expression data were correlated with the tumour stages. Fourteen healthy individuals served as controls. Results Significant correlations with tumour stages were found in single gene analyses of ga733.2, muc-1 and in multi-gene analyses of ga733.2/muc-1/mgb1/spdef. Furthermore, a significant correlation of Ca 15-3 and all studied genes was also observed. Conclusion Herein, we demonstrated a positive correlation of a gene signature consisting of ga733.2, muc-1, mgb1 and spdef and advanced stages of BC. Moreover, all studied genes and gene patterns revealed a significant correlation with Ca 15-3 positive cases.

  3. Assessment of the response of tumours to radiation: clinical and experimental studies

    International Nuclear Information System (INIS)

    Suit, H.D.; Walker, A.M.

    1980-01-01

    There is an important and active research programme at the laboratory and clinical level to develop indicators of the ultimate local response of tumours to radiation. In order to be of great value clinically indicators should yield a high true positivity and a low false positivity so that revisions of therapeutic strategy will be made only when there is a real need for such a change. The available data in the literature from the clinical studies, when analysed in terms of the true and false positive rates, indicate that the extent of regression at the completion of external beam therapy is not a useful prognostic indicator. This pertains to populations of tumour of a specific histopathological type, tumour size and anatomic site. Studies of laboratory animal tumour models have shown that regression patterns may be useful prognostic indicators for a tumour which is characterized by moderate immunogenicity and where there is close correlation between complete regression and permanent control. In contrast for tumours which are weakly or nonimmunogenic and which regress completely even at low tumour control probabilities, the pattern of regression has not been demonstrated to be of prognostic value. (author)

  4. Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

    International Nuclear Information System (INIS)

    Ng, Jin Aun; Booth, Jeremy T.; Poulsen, Per R.; Fledelius, Walther; Worm, Esben Schjødt; Eade, Thomas; Hegi, Fiona; Kneebone, Andrew; Kuncic, Zdenka; Keall, Paul J.

    2012-01-01

    Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced ≥3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of ≥3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

  5. A Study to Quantify the Effectiveness of Daily Endorectal Balloon for Prostate Intrafraction Motion Management

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ken Kang-Hsin, E-mail: wangken@uphs.upenn.edu [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States); Vapiwala, Neha; Deville, Curtiland; Plastaras, John P.; Scheuermann, Ryan; Lin Haibo; Bar Ad, Voika; Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)

    2012-07-01

    Purpose: To quantify intrafraction prostate motion between patient groups treated with and without daily endorectal balloon (ERB) employed during prostate radiotherapy and establish the effectiveness of the ERB. Methods: Real-time intrafraction prostate motion from 29 non-ERB (1,061 sessions) and 30 ERB (1,008 sessions) patients was evaluated based on three-dimensional (3D), left, right, cranial, caudal, anterior, and posterior displacements. The average percentage of time with 3D and unidirectional prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1-min intervals was calculated for up to 6 min of treatment time. The Kolmogorov-Smirnov method was used to evaluate the intrafraction prostate motion pattern between both groups. Results: Large 3D motion (up to 1 cm or more) was only observed in the non-ERB group. The motion increased as a function of elapsed time for displacements >2-8 mm for the non-ERB group and >2-4 mm for the ERB group (p < 0.05). The percentage time distributions between the two groups were significantly different for motion >5 mm (p < 0.05). The 3D symmetrical internal margin (IM) can be reduced from 5 to 3 mm (40% reduction), whereas the asymmetrical IM can be reduced from 3 to 2 mm (33% reduction) in cranial, caudal, anterior, and posterior for 6 min of treatment, when ERB is used. Beyond 6 min, the symmetrical 3D and asymmetrical cranial, caudal, anterior, and posterior IMs can be reduced from 9, 4, 7, 7, and 8 to 5, 2, 5, 3, and 4 mm, respectively (up to 57% reduction). Conclusion: The percentage of time that the prostate was displaced in any direction was less in the ERB group for almost all magnitudes of motion considered. The directional analysis shows that the ERB reduced IMs in almost all directions, especially the anterior-posterior direction.

  6. Tirapazamine causes vascular dysfunction in HCT-116 tumour xenografts

    International Nuclear Information System (INIS)

    Huxham, Lynsey A.; Kyle, Alastair H.; Baker, Jennifer H.E.; McNicol, Krista L.; Minchinton, Andrew I.

    2006-01-01

    Background and purpose: Tirapazamine is a hypoxic cytotoxin currently undergoing Phase II/III clinical evaluation in combination with radiation and chemotherapeutics for the treatment of non-hematological cancers. Tissue penetration studies using multicellular models have suggested that tirapazamine exposure may be limited to cells close to blood vessels. However, animal studies show tirapazamine enhances the anti-tumour activity of radiation and chemotherapy and clinical studies with tirapazamine, so far, are promising. To investigate this apparent paradox we examined the microregional effects of tirapazamine in vivo by mapping drug effects with respect to the position of blood vessels in tumour cryosections. Patients and methods: Tirapazamine was administered i.p. to mice bearing HCT-116 tumours, which were excised at various times after treatment. Images of multiple-stained cryosections were overlaid to provide microregional information on the relative position of proliferating cells, hypoxia, perfusion and vasculature. Results: We observed extensive and permanent vascular dysfunction in a large proportion of tumours from mice treated with tirapazamine. In the affected tumours, blood flow ceased in the centrally located tumour vessels, leaving a rim of functional vessels around the periphery of the tumour. This vascular dysfunction commenced within 24 h after tirapazamine administration and the areas affected appeared to be replaced by necrosis over the following 24-48 h. Conclusions: Because the majority of hypoxic cells are located in the center of tumours we propose that the activity of tirapazamine in vivo may be related to its effects on tumour vasculature and that its activity against hypoxic cells located distal to functional blood vessels may not be as important as previously believed

  7. SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

    International Nuclear Information System (INIS)

    Shimohigashi, Y; Araki, F; Toya, R; Maruyama, M; Nakaguchi, Y

    2016-01-01

    Purpose: The purpose of this study was to evaluate the interfractional and intrafractional motion of liver tumors in stereotactic body radiation therapy (SBRT), based on four-dimensional cone-beam computed tomography using fiducial markers. (4D-CBCT). Methods: Seven patients with liver tumors were treated by SBRT with abdominal compression (AC) in five fractions with image guidance based on 4D-CBCT. The 4D-CBCT studies were performed to determine the individualized internal margin for the planning simulation. The interfractional and intrafractional changes of liver tumor motion for all patients was measured, based on the planning simulation 4D-CBCT, pre-SBRT 4D-CBCT, and post-SBRT 4D-CBCT. The interfractional motion change was calculated from the difference in liver tumor amplitude on pre-SBRT 4D-CBCT relative to that of the planning simulation 4D-CBCT for each fraction. The intrafractional motion change was calculated from the difference between the liver tumor amplitudes of the pre- and post-SBRT 4D-CBCT for each fraction. Significant interfractional and intrafractional changes in liver tumor motion were defined as a change ≥3 mm. Statistical analysis was performed using the Pearson correlation. Results: The values of the mean amplitude of liver tumor, as indicated by planning simulation 4D-CBCT, were 1.6 ± 0.8 mm, 1.6 ± 0.9 mm, and 4.9 ± 2.2 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Pearson correlation coefficients between the liver tumor amplitudes, based on planning simulation 4D-CBCT, and pre-SBRT 4D-CBCT during fraction treatment in the LR, AP, and SI directions were 0.6, 0.7, and 0.8, respectively. Interfractional and intrafractional motion changes of ≥3 mm occurred in 23% and 3% of treatment fractions, respectively. Conclusion: The interfractional and intrafractional changes of liver tumor motion were small in most patients who received liver SBRT with AC. In addition, planning

  8. SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

    Energy Technology Data Exchange (ETDEWEB)

    Shimohigashi, Y [Department of Radiological Technology, Kumamoto University Hospital, Department of Graduate School of Health Sciences, Kumamoto University (Japan); Araki, F [Department of Health Sciences, Kumamoto University (Japan); Toya, R [Department of Radiation Oncology, Kumamoto University Hospital (Japan); Department of Human Oncology, University of Wisconsin School of Medicine and Public Health (United States); Maruyama, M; Nakaguchi, Y [Department of Radiological Technology, Kumamoto University Hospital (Japan)

    2016-06-15

    Purpose: The purpose of this study was to evaluate the interfractional and intrafractional motion of liver tumors in stereotactic body radiation therapy (SBRT), based on four-dimensional cone-beam computed tomography using fiducial markers. (4D-CBCT). Methods: Seven patients with liver tumors were treated by SBRT with abdominal compression (AC) in five fractions with image guidance based on 4D-CBCT. The 4D-CBCT studies were performed to determine the individualized internal margin for the planning simulation. The interfractional and intrafractional changes of liver tumor motion for all patients was measured, based on the planning simulation 4D-CBCT, pre-SBRT 4D-CBCT, and post-SBRT 4D-CBCT. The interfractional motion change was calculated from the difference in liver tumor amplitude on pre-SBRT 4D-CBCT relative to that of the planning simulation 4D-CBCT for each fraction. The intrafractional motion change was calculated from the difference between the liver tumor amplitudes of the pre- and post-SBRT 4D-CBCT for each fraction. Significant interfractional and intrafractional changes in liver tumor motion were defined as a change ≥3 mm. Statistical analysis was performed using the Pearson correlation. Results: The values of the mean amplitude of liver tumor, as indicated by planning simulation 4D-CBCT, were 1.6 ± 0.8 mm, 1.6 ± 0.9 mm, and 4.9 ± 2.2 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Pearson correlation coefficients between the liver tumor amplitudes, based on planning simulation 4D-CBCT, and pre-SBRT 4D-CBCT during fraction treatment in the LR, AP, and SI directions were 0.6, 0.7, and 0.8, respectively. Interfractional and intrafractional motion changes of ≥3 mm occurred in 23% and 3% of treatment fractions, respectively. Conclusion: The interfractional and intrafractional changes of liver tumor motion were small in most patients who received liver SBRT with AC. In addition, planning

  9. Imaging of gastrointestinal stromal tumour (GIST)

    International Nuclear Information System (INIS)

    Lau, S.; Tam, K.F.; Kam, C.K.; Lui, C.Y.; Siu, C.W.; Lam, H.S.; Mak, K.L.

    2004-01-01

    Gastrointestinal stromal tumour (GIST) represents the most common kind of mesenchymal tumour that arises from the alimentary tract. GIST is currently defined as a gastrointestinal tract mesenchymal tumour containing spindle cells (or less commonly epithelioid cells or rarely both) and showing CD117 (c-kit protein) positivity. Targeted molecular therapy of non-resectable GIST using imatinib, a specific tyrosine kinase receptor inhibitor, represents a real milestone in the management of solid malignancy. Imaging studies, both anatomical and functional, are playing an increasingly important role in management of patients with GIST. This review illustrates the radiological appearance of GISTs and the site-specific roles of each imaging tool. Clinical features and radiological differential diagnosis of GIST are also discussed

  10. Oral Squamomelanocytic Tumour in a Dog: a Unique Biphasic Cancer.

    Science.gov (United States)

    Muscatello, L V; Avallone, G; Benazzi, C; Sarli, G; Porcellato, I; Brachelente, C; Brunetti, B

    2016-01-01

    In human medicine, squamomelanocytic tumour is a malignant cutaneous neoplasm composed of closely intermingled neoplastic squamous cells and melanocytes. A multinodular gingival tumour in a 16-year-old, mixed breed neutered female dog was examined microscopically. Two populations of neoplastic cells, melanocytic and squamous epithelial cells were intermingled. The melanocytic cells were melan-A positive and cytokeratin AE1-AE3 negative and the squamous component was cytokeratin AE1-AE3 positive and melan-A negative. Bovine papillomavirus was not identified by immunohistochemistry or polymerase chain reaction. A diagnosis of squamomelanocytic tumour was made. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Some aspects of the endocrine tumours of the digestive tract

    International Nuclear Information System (INIS)

    Sassolas, G.

    1996-01-01

    Endocrine tumours of digestive tract (GEP) synthesize many hormonal products which are responsible for clinical expression in relation with their nature, amount and biological activity, some of these tumours being non-functioning or silent. Moreover these tumours have some characteristics related to neuroendocrine differentiation, which provide tumour markers in addition to hormonal markers, such as chromogranin. A which is of special interest in non-functioning tumours. Pancreatic tumours are the most frequently recognized tumours in systematic screening procedures performed in MEN 1 patients. They are multi-secreting and multifocal, and they exhibit a loss of heterozygosity in the 11q13 locus. Growth factors such as IGF-1 and PDGF and their specific receptors are expressed in GEP tumours but their role in tumour growth remains to be determined. Somatostatin receptors are present on most endocrine digestive tumours, conditioning the therapeutic effects of somatostatin analogues that reduce hormonal tumoral production and alleviate the related symptoms. In addition, in vivo visualization of somatostatin receptor positive tumours by scintigraphy using radiolabelled somatostatin analogues is of clinical interest. (author)

  12. Elevated tumour marker: an indication for imaging?

    LENUS (Irish Health Repository)

    McMahon, Colm J

    2012-02-01

    INTRODUCTION: The purpose of this study was to evaluate the utility of imaging examinations in patients with elevated tumour markers when (a) the tumour marker is not validated for as a primary diagnostic test; (b) the patient had no personal history of cancer and (c) the patient had no other imaging indication. MATERIALS AND METHODS: Patients without known cancer who had abnormal carcinoembryonic antigen, CA19-9, CA125 and\\/or CA15-3 serology over a one-year period were included. A retrospective medical record review was performed to assess the number of these cases who underwent imaging because of \\'elevated tumour marker\\' in the absence of a clinical indication for imaging. The number and result of these imaging studies were evaluated. RESULTS: Eight hundred and nineteen patients were included. Of those, 25 patients (mean age: 67.8 [range 41-91] y), were imaged to evaluate: \\'elevated tumour marker\\'. They underwent 29 imaging studies (mean [+\\/-standard deviation (SD)] per patient = 1.2 [+\\/-0.4]), and had 42 elevated tumour marker serology tests (mean [+\\/-SD] per patient = 1.7 [+\\/-0.7]). Four patients had >1 imaging test. No patient had an imaging study which diagnosed a malignancy or explained the elevated tumour marker. CONCLUSION: The non-judicious use of tumour markers can prompt further unnecessary investigations including imaging. In this study, there was no positive diagnostic yield for imaging performed for investigation of \\'elevated tumour marker\\'. \\'Elevated tumour marker\\

  13. Double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours.

    Science.gov (United States)

    Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R

    2013-06-10

    Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.

  14. Adenomyoepithelial tumours and myoepithelial carcinomas of the breast – a spectrum of monophasic and biphasic tumours dominated by immature myoepithelial cells

    Directory of Open Access Journals (Sweden)

    Herbst Hermann

    2005-07-01

    Full Text Available Abstract Background Adenomyoepithelial tumours and myoepithelial carcinomas of the breast are primarily defined by the presence of neoplastic cells with a myoepithelial immunophenotype. Current classification schemes are based on purely descriptive features and an assessment of individual prognosis is still problematic. Methods A series of 27 adenomyoepithelial tumours of the breast was analysed immunohistochemically with antibodies directed against various cytokeratins, p63, smooth muscle alpha-actin (SMA and vimentin. Additionally, double immunofluorescence and comparative genomic hybridisation (CGH was performed. Results Immunohistochemically, all the tumours showed a constant expression of high molecular weight cytokeratins (Ck Ck5 and Ck14, p63, SMA and vimentin. With exception of one case diagnosed as myoepithelial carcinoma, all tested tumours expressed low molecular weight cytokeratin Ck18 in variable proportions of cells. Even in monophasic tumours lacking obvious glandular differentiation in conventional staining, a number of neoplastic cells still expressed those cytokeratins. Double immunofluorescence revealed tumour cells exclusively staining for Ck5/Ck14 in the presence of other cell populations that co-expressed high molecular weight Ck5/Ck14 as well as either low molecular weight Ck8/18 or SMA. Based on morphology, we assigned the series to three categories, benign, borderline and malignant. This classification was supported by a stepwise increase in cytogenetic alterations on CGH. Conclusion Adenomyoepithelial tumours comprise a spectrum of neoplasms consisting of an admixture of glandular and myoepithelial differentiation patterns. As a key component SMA-positive cells co-expressing cytokeratins could be identified. Although categorisation of adenomyoepithelial tumours in benign, borderline and malignant was supported by results of CGH, any assessment of prognosis requires to be firmly based on morphological grounds. At present

  15. Correlation between tumour characteristics, SUV measurements, metabolic tumour volume, TLG and textural features assessed with 18F-FDG PET in a large cohort of oestrogen receptor-positive breast cancer patients.

    Science.gov (United States)

    Lemarignier, Charles; Martineau, Antoine; Teixeira, Luis; Vercellino, Laetitia; Espié, Marc; Merlet, Pascal; Groheux, David

    2017-07-01

    The study was designed to evaluate 1) the relationship between PET image textural features (TFs) and SUVs, metabolic tumour volume (MTV), total lesion glycolysis (TLG) and tumour characteristics in a large prospective and homogenous cohort of oestrogen receptor-positive (ER+) breast cancer (BC) patients, and 2) the capability of those parameters to predict response to neoadjuvant chemotherapy (NAC). 171 consecutive patients with large or locally advanced ER+ BC without distant metastases underwent an 18 F-FDG PET examination before NAC. The primary tumour was delineated with an adaptive threshold segmentation method. Parameters of volume, intensity and texture (entropy, homogeneity, contrast and energy) were measured and compared with tumour characteristics determined on pre-treatment breast biopsy (Wilcoxon rank-sum test). The correlation between PET-derived parameters was determined using Spearman's coefficient. The relationship between PET features and pathological findings was determined using the Wilcoxon rank-sum test. Spearman's coefficients between SUV max and TFs were 0.43, 0.24, -0.43 and -0.15 respectively for entropy, homogeneity, energy and contrast; they were higher between MTV and TFs: 0.99, 0.86, -0.99 and -0.87. All TFs showed a significant association with the histological type (IDC vs. ILC; 0.02 < P < 0.03) but didn't with immunohistochemical characteristics. SUV max and TLG predicted the pathological response (P = 0.0021 and P = 0.02 respectively); TFs didn't (P: 0.27, 0.19, 0.94, 0.19 respectively for entropy, homogeneity, energy and contrast). The correlation of TFs was poor with SUV parameters and high with MTV. TFs showed a significant association with the histological type. Finally, while SUV max and TLG were able to predict response to NAC, TFs failed.

  16. Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Omari, Eenas A.; Erickson, Beth; Noid, George; Li, X. Allen, E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Ehlers, Christopher; Quiroz, Francisco [Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Cooper, David T.; Lachaine, Martin [Elekta Ltd., Montreal, Québec H3A 2J5 (Canada)

    2016-09-15

    Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an

  17. Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

    International Nuclear Information System (INIS)

    Omari, Eenas A.; Erickson, Beth; Noid, George; Li, X. Allen; Ehlers, Christopher; Quiroz, Francisco; Cooper, David T.; Lachaine, Martin

    2016-01-01

    Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an

  18. Radiofrequency ablation of renal tumours: diagnostic accuracy of contrast-enhanced ultrasound for early detection of residual tumour

    International Nuclear Information System (INIS)

    Hoeffel, Christine; Pousset, Maud; Elie, Caroline; Timsit, Marc-Olivier; Mejean, Arnaud; Merran, Samuel; Tranquart, Francois; Khairoune, Ahmed; Helenon, Olivier; Correas, Jean-Michel; Joly, Dominique; Richard, Stephane

    2010-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in the early detection of residual tumour after radiofrequency ablation (RFA) of renal tumours. Patients referred to our institution for RFA of renal tumours prospectively underwent CEUS and computed tomography (CT) or magnetic resonance imaging (MRI) before, within 1 day and 6 weeks after treatment. Identification of residual tumour was assessed by three blinded radiologists. Reference standard was CT/MRI performed at least 1 year after RFA. A total of 66 renal tumours in 43 patients (median age 62 years; range 44-71.5) were studied. Inter-reader agreement (κ value) was 0.84 for CEUS. Prevalence of residual disease was 19%. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), respectively, were as follows: 64% [confidence interval (CI) 39-84], 98% [CI 91-100], 82% [CI 52-95] and 92% [CI 83-97] on 24-h CEUS; 79% [CI 52-92], 100% [CI 94-100], 100% [CI 74-100] and 95% [CI 87-100] on 6-week CEUS; 79% [CI 52-92], 95% [CI 86-98], 79% [CI 52-92] and 95% [CI 86-98] on 24-h CT/MRI; and 100% [CI 72-100], 98% [CI 90-100], 91% [CI 62-98] and 100% [CI 93-100] on 6-week CT/MRI. CEUS has high specificity for the early diagnosis of residual tumour after renal RFA. (orig.)

  19. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  20. Ten years summary: FDG-PET on irradiated brain tumour

    International Nuclear Information System (INIS)

    Wang Shuxia; Boethius, J.

    2004-01-01

    Purpose: To retrospectively evaluate FDG-PET in differentiation of post-radiotherapy status: recurrence, radiation necrosis, malignant regression of low grade primary brain tumour, and to evaluate PET in terms of survival prediction. Material and methods: 117 irradiated patients (156 PET) were consecutively included. PET results were judged by a set of rigid follow-up standards. Brain metastases from lung carcinoma were further studied. Survival time was analysed with Kaplan-Meier method. Results: There were 61 true-positive, 2 false-positive, 15 false-negative, 51 true-negative PET; leaving 5 positive and 22 negative PET results indeterminate. PET positive predictive value was 96% in all and 100% in brain metastasis from lung carcinoma. PET negative predictive value was 55.6% among surgically selected cases. Survival time was significantly longer in patient's with negative PET, both brain metastasis and primary brain tumour. Conclusions: FDG-PET was a good method to pick up tumour recurrence from radiation necrosis, especially metastasis from lung carcinoma. FDG uptake could be used as a non-invasive parameter to predict patient's prognosis. (authors)

  1. Narrative skills of children treated for brain tumours: The impact of tumour and treatment related variables on microstructure and macrostructure.

    Science.gov (United States)

    Docking, Kimberley; Munro, Natalie; Marshall, Tara; Togher, Leanne

    2016-01-01

    The narrative skills of children with brain tumours were examined. Influence of tumour location, radiotherapy, time post-treatment and presence of hydrocephalus was also investigated, as well as associations between narrative and language abilities. Seventeen children (aged 5;6-14;11) treated for brain tumour and their matched controls completed a narrative assessment and comprehensive language testing. Audio recorded narratives were analysed for microstructure and macrostructure elements. Between-group comparisons were conducted. Narrative elements were explored in association with tumour and treatment-related variables. Correlation analysis examined relationships between narrative scores and language test performance. While significant differences were not found between two groups of children across narrative elements, sub-group comparisons revealed marginal differences in macrostructure related to tumour location and hydrocephalus. Children treated with methods other than radiotherapy showed a significant increase in number of mazes in their narratives compared to children who received radiotherapy. Strong positive correlations also existed between narrative elements and language performance. Preliminary findings highlight the importance of investigating narrative abilities as part of a comprehensive language assessment. Macrostructure should be routinely examined where children are diagnosed with either posterior fossa tumour or hydrocephalus or have undergone surgery and/or chemotherapy for brain tumour.

  2. Contribution of gammagraphy to the diagnosis of bone tumours. Study of 270 patients

    International Nuclear Information System (INIS)

    Caballero Carpena, O.; Esteban Velasco, J.

    1982-01-01

    In this study, two hundred seventy patients with bone tumours were evaluated by whole-body radionuclide studies: bone and vascular scan, using 99mTc MDP. In the group of primary bone tumour: 50 cases, the gammagraphy was positive in all cases except one myeloma. The morphology of the abnormal scan area of a primary bone tumour depend more of the site of the bone lesion than on its histopathology, and the size is significant by larger in sarcoma than others. The positivity of gammagraphy in the group of secondary bone tumours: 220 cases, was 93%, and the gammagraphic diagnosis being earlier than the radiologic one in 27%. Finally, we have studied the location of metastases, and the correlation between the positive scan and the request of exploration

  3. Tumour location within the breast: Does tumour site have prognostic ability?

    Science.gov (United States)

    Rummel, Seth; Hueman, Matthew T; Costantino, Nick; Shriver, Craig D; Ellsworth, Rachel E

    2015-01-01

    Tumour location within the breast varies with the highest frequency in the upper outer quadrant (UOQ) and lowest frequency in the lower inner quadrant (LIQ). Whether tumour location is prognostic is unclear. To determine whether tumour location is prognostic, associations between tumour site and clinicopathological characteristics were evaluated. All patients enrolled in the Clinical Breast Care Project whose tumour site-UOQ, upper inner quadrant (UIQ), central, LIQ, lower outer quadrant (LOQ)-was determined by a single, dedicated breast pathologist were included in this study. Patients with multicentric disease (n = 122) or tumours spanning multiple quadrants (n = 381) were excluded from further analysis. Clinicopathological characteristics were analysed using chi-square tests for univariate analysis with multivariate analysis performed using principal components analysis (PCA) and multiple logistic regression. Significance was defined as P location, 30 had bilateral disease. Tumour location in the UOQ (51.5%) was significantly higher than in the UIQ (15.6%), LOQ (14.2%), central (10.6%), or LIQ (8.1%). Tumours in the central quadrant were significantly more likely to have higher tumour stage (P = 0.003) and size (P location as a prognostic factor revealed that although tumours in the central region are associated with less favourable outcome, these associations are not independent of location but rather driven by larger tumour size. Tumours in the central region are more difficult to detect mammographically, resulting in larger tumour size at diagnosis and thus less favourable prognosis. Together, these data demonstrate that tumour location is not an independent prognostic factor.

  4. Double-labelling immunohistochemistry for MGMT and a “cocktail” of non-tumourous elements is a reliable, quick and easy technique for inferring methylation status in glioblastomas and other primary brain tumours

    Science.gov (United States)

    2013-01-01

    Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243

  5. SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H [Interdisciplinary Program in Radiation Applied Life Science, College of Medicine, Seoul National University, Seoul (Korea, Republic of); Kim, I [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Ye, S [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

  6. SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

    International Nuclear Information System (INIS)

    Kim, H; Kim, I; Ye, S

    2016-01-01

    Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

  7. Development of a potent DOTA-conjugated bombesin antagonist for targeting GRPr-positive tumours

    Energy Technology Data Exchange (ETDEWEB)

    Mansi, Rosalba; Maecke, Helmut R. [University Hospital Basel, Division of Radiological Chemistry, Basel (Switzerland); University of Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Wang, Xuejuan [University Hospital Basel, Division of Radiological Chemistry, Basel (Switzerland); Forrer, Flavio [University Hospital Basel, Institute of Nuclear Medicine, Basel (Switzerland); Erasmus Medical Centre, Nuclear Medicine, Rotterdam (Netherlands); Waser, Beatrice; Cescato, Renzo; Reubi, Jean Claude [University of Berne, Division of Cell Biology and Experimental Cancer Research, Institute of Pathology, Berne (Switzerland); Graham, Keith; Borkowski, Sandra [Bayer Schering Pharma AG, Global Drug Discovery, Berlin (Germany)

    2011-01-15

    Radiolabelled somatostatin-based antagonists show a higher uptake in tumour-bearing mouse models than agonists of similar or even distinctly higher receptor affinity. Very similar results were obtained with another family of G protein-coupled receptor ligands, the bombesin family. We describe a new conjugate, RM2, with the chelator DOTA coupled to D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH{sub 2} via the cationic spacer 4-amino-1-carboxymethyl-piperidine for labelling with radiometals such as {sup 111}In and {sup 68}Ga. RM2 was synthesized on a solid support and evaluated in vitro in PC-3 cells. IC{sub 50} and K{sub d} values were determined. The antagonist potency was evaluated by immunofluorescence-based internalization and Ca{sup 2+} mobilization assays. Biodistribution studies were performed in PC-3 and LNCaP tumour-bearing mice with {sup 111}In-RM2 and {sup 68}Ga-RM2, respectively. PET/CT studies were performed on PC-3 and LNCaP tumour-bearing nude mice with {sup 68}Ga-RM2. RM2 and {sup 111}In-RM2 are high-affinity and selective ligands for the GRP receptor (7.7{+-}3.3 nmol/l for RM2; 9.3{+-}3.3 nmol/l for {sup nat}In-RM2). The potent antagonistic properties were confirmed by an immunofluorescence-based internalization and Ca{sup 2+} mobilization assays. {sup 68}Ga- and {sup 111}In-RM2 showed high and specific uptake in both the tumour and the pancreas. Uptake in the tumour remained high (15.2{+-}4.8%IA/g at 1 h; 11.7{+-}2.4%IA/g at 4 h), whereas a relatively fast washout from the pancreas and the other abdominal organs was observed. Uptake in the pancreas decreased rapidly from 22.6{+-}4.7%IA/g at 1 h to 1.5{+-}0.5%IA/g at 4 h. RM2 was shown to be a potent GRPr antagonist. Pharmacokinetics and imaging studies indicate that {sup 111}In-RM2 and {sup 68}Ga-RM2 are ideal candidates for clinical SPECT and PET studies. (orig.)

  8. Development of a potent DOTA-conjugated bombesin antagonist for targeting GRPr-positive tumours

    International Nuclear Information System (INIS)

    Mansi, Rosalba; Maecke, Helmut R.; Wang, Xuejuan; Forrer, Flavio; Waser, Beatrice; Cescato, Renzo; Reubi, Jean Claude; Graham, Keith; Borkowski, Sandra

    2011-01-01

    Radiolabelled somatostatin-based antagonists show a higher uptake in tumour-bearing mouse models than agonists of similar or even distinctly higher receptor affinity. Very similar results were obtained with another family of G protein-coupled receptor ligands, the bombesin family. We describe a new conjugate, RM2, with the chelator DOTA coupled to D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH 2 via the cationic spacer 4-amino-1-carboxymethyl-piperidine for labelling with radiometals such as 111 In and 68 Ga. RM2 was synthesized on a solid support and evaluated in vitro in PC-3 cells. IC 50 and K d values were determined. The antagonist potency was evaluated by immunofluorescence-based internalization and Ca 2+ mobilization assays. Biodistribution studies were performed in PC-3 and LNCaP tumour-bearing mice with 111 In-RM2 and 68 Ga-RM2, respectively. PET/CT studies were performed on PC-3 and LNCaP tumour-bearing nude mice with 68 Ga-RM2. RM2 and 111 In-RM2 are high-affinity and selective ligands for the GRP receptor (7.7±3.3 nmol/l for RM2; 9.3±3.3 nmol/l for nat In-RM2). The potent antagonistic properties were confirmed by an immunofluorescence-based internalization and Ca 2+ mobilization assays. 68 Ga- and 111 In-RM2 showed high and specific uptake in both the tumour and the pancreas. Uptake in the tumour remained high (15.2±4.8%IA/g at 1 h; 11.7±2.4%IA/g at 4 h), whereas a relatively fast washout from the pancreas and the other abdominal organs was observed. Uptake in the pancreas decreased rapidly from 22.6±4.7%IA/g at 1 h to 1.5±0.5%IA/g at 4 h. RM2 was shown to be a potent GRPr antagonist. Pharmacokinetics and imaging studies indicate that 111 In-RM2 and 68 Ga-RM2 are ideal candidates for clinical SPECT and PET studies. (orig.)

  9. Correlation between tumour characteristics, SUV measurements, metabolic tumour volume, TLG and textural features assessed with {sup 18}F-FDG PET in a large cohort of oestrogen receptor-positive breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Lemarignier, Charles; Groheux, David [Saint-Louis Hospital, Assistance Publique - Hopitaux de Paris, Department of Nuclear Medicine, Paris (France); University Sorbonne Paris Cite, INSERM/CNRS UMR944/7212, Paris (France); Martineau, Antoine; Vercellino, Laetitia; Merlet, Pascal [Saint-Louis Hospital, Assistance Publique - Hopitaux de Paris, Department of Nuclear Medicine, Paris (France); Teixeira, Luis; Espie, Marc [Saint-Louis Hospital, Breast Diseases Unit, Paris (France); University Sorbonne Paris Cite, INSERM/CNRS UMR944/7212, Paris (France)

    2017-07-15

    The study was designed to evaluate 1) the relationship between PET image textural features (TFs) and SUVs, metabolic tumour volume (MTV), total lesion glycolysis (TLG) and tumour characteristics in a large prospective and homogenous cohort of oestrogen receptor-positive (ER+) breast cancer (BC) patients, and 2) the capability of those parameters to predict response to neoadjuvant chemotherapy (NAC). 171 consecutive patients with large or locally advanced ER+ BC without distant metastases underwent an {sup 18}F-FDG PET examination before NAC. The primary tumour was delineated with an adaptive threshold segmentation method. Parameters of volume, intensity and texture (entropy, homogeneity, contrast and energy) were measured and compared with tumour characteristics determined on pre-treatment breast biopsy (Wilcoxon rank-sum test). The correlation between PET-derived parameters was determined using Spearman's coefficient. The relationship between PET features and pathological findings was determined using the Wilcoxon rank-sum test. Spearman's coefficients between SUV{sub max} and TFs were 0.43, 0.24, -0.43 and -0.15 respectively for entropy, homogeneity, energy and contrast; they were higher between MTV and TFs: 0.99, 0.86, -0.99 and -0.87. All TFs showed a significant association with the histological type (IDC vs. ILC; 0.02 < P < 0.03) but didn't with immunohistochemical characteristics. SUV{sub max} and TLG predicted the pathological response (P = 0.0021 and P = 0.02 respectively); TFs didn't (P: 0.27, 0.19, 0.94, 0.19 respectively for entropy, homogeneity, energy and contrast). The correlation of TFs was poor with SUV parameters and high with MTV. TFs showed a significant association with the histological type. Finally, while SUV{sub max} and TLG were able to predict response to NAC, TFs failed. (orig.)

  10. Utility of Phox2b immunohistochemical stain in neural crest tumours and non-neural crest tumours in paediatric patients.

    Science.gov (United States)

    Warren, Mikako; Matsuno, Ryosuke; Tran, Henry; Shimada, Hiroyuki

    2018-03-01

    This study evaluated the utility of Phox2b in paediatric tumours. Previously, tyrosine hydroxylase (TH) was the most widely utilised sympathoadrenal marker specific for neural crest tumours with neuronal/neuroendocrine differentiation. However, its sensitivity is insufficient. Recently Phox2b has emerged as another specific marker for this entity. Phox2b immunohistochemistry (IHC) was performed on 159 paediatric tumours, including (group 1) 65 neural crest tumours with neuronal differentiation [peripheral neuroblastic tumours (pNT)]: 15 neuroblastoma undifferentiated (NB-UD), 10 NB poorly differentiated (NB-PD), 10 NB differentiating (NB-D), 10 ganglioneuroblastoma intermixed (GNBi), 10 GNB nodular (GNBn) and 10 ganglioneuroma (GN); (group 2) 23 neural crest tumours with neuroendocrine differentiation [pheochromocytoma/paraganglioma (PCC/PG)]; (group 3) 27 other neural crest tumours including one composite rhabdomyosarcoma/neuroblastoma; and (group 4) 44 non-neural crest tumours. TH IHC was performed on groups 1, 2 and 3. Phox2b was expressed diffusely in pNT (n = 65 of 65), strongly in NB-UD and NB-PD and with less intensity in NB-D, GNB and GN. Diffuse TH was seen in all NB-PD, NB-D, GNB and GN, but nine of 15 NB-UD and a nodule in GNBn did not express TH (n = 55 of 65). PCC/PG expressed diffuse Phox2b (n = 23 of 23) and diffuse TH, except for one tumour (n = 22 of 23). In composite rhabdomyosarcoma, TH was expressed only in neuroblastic cells and Phox2b was diffusely positive in neuroblastic cells and focally in rhabdomyosarcoma. All other tumours were negative for Phox2b (n = none of 44). Phox2b was a specific and sensitive marker for pNT and PCC/PG, especially useful for identifying NB-UD often lacking TH. Our study also presented a composite rhabdomyosarcoma/neuroblastoma of neural crest origin. © 2017 John Wiley & Sons Ltd.

  11. A cinematic magnetic resonance imaging study of milk of magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion.

    Science.gov (United States)

    Nichol, Alan M; Warde, Padraig R; Lockwood, Gina A; Kirilova, Anna K; Bayley, Andrew; Bristow, Robert; Crook, Juanita; Gospodarowicz, Mary; McLean, Michael; Milosevic, Michael; Rosewall, Tara; Jaffray, David A; Catton, Charles N

    2010-07-15

    To determine the reduction of prostate motion during a typical radiotherapy (RT) fraction from a bowel regimen comprising an antiflatulent diet and daily milk of magnesia. Forty-two patients with T1c-T2c prostate cancer voided the bladder and rectum before three cinematic magnetic resonance imaging scans obtained every 9 s for 9 min in a vacuum immobilization device. The MRIs were at baseline without bowel regimen (MRI-BL), before CT planning with bowel regimen (MRI-CT), and before a randomly assigned RT fraction (1-42) with bowel regimen (MRI-RT). A single observer tracked displacement of the posterior midpoint (PM) of the prostate. The primary endpoints were comparisons of the proportion of time that the PM was displaced >3 mm (PTPM3) from its initial position, and the secondary endpoints were comparisons of the reduction of initial rectal area, with and without the bowel regimen. The mean rectal area was: 13.5 cm(2) at MRI-BL, 12.7 cm(2) at MRI-CT, and 12.3 cm(2) at MRI-RT (MRI-BL vs. MRI-CT, p = 0.11; MRI-BL vs. MRI-CT, p = 0.07). Moving rectal gas alone (56%) and moving gas and stool (18%) caused 74% of intrafraction prostate motion. The PTPM3 was 11.3% at MRI-BL, 4.8% at MRI-CT, and 12.0% at MRI-RT (MRI-BL vs. MRI-CT, p = 0.12; MRI-BL vs. MRI-RT, p = 0.89). For subjects voiding their rectum before imaging, an antiflatulent diet and milk of magnesia laxative did not significantly reduce initial rectal area or intrafraction prostate motion. Copyright 2010 Elsevier Inc. All rights reserved.

  12. A Cinematic Magnetic Resonance Imaging Study of Milk of Magnesia Laxative and an Antiflatulent Diet to Reduce Intrafraction Prostate Motion

    International Nuclear Information System (INIS)

    Nichol, Alan M.; Warde, Padraig R.; Lockwood, Gina A.

    2010-01-01

    Purpose: To determine the reduction of prostate motion during a typical radiotherapy (RT) fraction from a bowel regimen comprising an antiflatulent diet and daily milk of magnesia. Methods and Materials: Forty-two patients with T1c-T2c prostate cancer voided the bladder and rectum before three cinematic magnetic resonance imaging scans obtained every 9 s for 9 min in a vacuum immobilization device. The MRIs were at baseline without bowel regimen (MRI-BL), before CT planning with bowel regimen (MRI-CT), and before a randomly assigned RT fraction (1-42) with bowel regimen (MRI-RT). A single observer tracked displacement of the posterior midpoint (PM) of the prostate. The primary endpoints were comparisons of the proportion of time that the PM was displaced >3 mm (PTPM3) from its initial position, and the secondary endpoints were comparisons of the reduction of initial rectal area, with and without the bowel regimen. Results: The mean rectal area was: 13.5 cm 2 at MRI-BL, 12.7 cm 2 at MRI-CT, and 12.3 cm 2 at MRI-RT (MRI-BL vs. MRI-CT, p = 0.11; MRI-BL vs. MRI-CT, p = 0.07). Moving rectal gas alone (56%) and moving gas and stool (18%) caused 74% of intrafraction prostate motion. The PTPM3 was 11.3% at MRI-BL, 4.8% at MRI-CT, and 12.0% at MRI-RT (MRI-BL vs. MRI-CT, p = 0.12; MRI-BL vs. MRI-RT, p = 0.89). Conclusion: For subjects voiding their rectum before imaging, an antiflatulent diet and milk of magnesia laxative did not significantly reduce initial rectal area or intrafraction prostate motion.

  13. Automated Image-Based Procedures for Adaptive Radiotherapy

    DEFF Research Database (Denmark)

    Bjerre, Troels

    be employed for contour propagation in adaptive radiotherapy. - MRI-radiotherapy devices have the potential to offer near real-time intrafraction imaging without any additional ionising radiation. It is detailed how the use of multiple, orthogonal slices can form the basis for reliable 3D soft tissue tracking.......-based treatment replanning and real-time intrafraction guidance techniques. The selected contributions detail a number of findings and techniques, in particular: - For ten head & neck cancer patients, changes in tumour density were well described by linear functions with patient-specific slope and intercept...

  14. Recent advances and opportunities in proteomic analyses of tumour heterogeneity.

    Science.gov (United States)

    Bateman, Nicholas W; Conrads, Thomas P

    2018-04-01

    Solid tumour malignancies comprise a highly variable admixture of tumour and non-tumour cellular populations, forming a complex cellular ecosystem and tumour microenvironment. This tumour heterogeneity is not incidental, and is known to correlate with poor patient prognosis for many cancer types. Indeed, non-malignant cell populations, such as vascular endothelial and immune cells, are known to play key roles supporting and, in some cases, driving aggressive tumour biology, and represent targets of emerging therapeutics, such as antiangiogenesis and immune checkpoint inhibitors. The biochemical interplay between these cellular populations and how they contribute to molecular tumour heterogeneity remains enigmatic, particularly from the perspective of the tumour proteome. This review focuses on recent advances in proteomic methods, namely imaging mass spectrometry, single-cell proteomic techniques, and preanalytical sample processing, that are uniquely positioned to enable detailed analysis of discrete cellular populations within tumours to improve our understanding of tumour proteomic heterogeneity. This review further emphasizes the opportunity afforded by the application of these techniques to the analysis of tumour heterogeneity in formalin-fixed paraffin-embedded archival tumour tissues, as these represent an invaluable resource for retrospective analyses that is now routinely accessible, owing to recent technological and methodological advances in tumour tissue proteomics. Copyright © 2018 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2018 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  15. Total {sup 18}F-dopa PET tumour uptake reflects metabolic endocrine tumour activity in patients with a carcinoid tumour

    Energy Technology Data Exchange (ETDEWEB)

    Fiebrich, Helle-Brit; Walenkamp, Annemiek M.; Vries, Elisabeth G.E. de [University Medical Centre Groningen, Department of Medical Oncology, Groningen (Netherlands); Jong, Johan R. de; Koopmans, Klaas Pieter; Dierckx, Rudi A.J.O.; Brouwers, Adrienne H. [University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Kema, Ido P. [University Medical Centre Groningen, Department of Laboratory Medicine, Groningen (Netherlands); Sluiter, Wim; Links, Thera P. [University Medical Centre Groningen, Department of Endocrinology, Groningen (Netherlands)

    2011-10-15

    Positron emission tomography (PET) using 6-[{sup 18}F]fluoro-L-dihydroxyphenylalanine ({sup 18}F-dopa) has an excellent sensitivity to detect carcinoid tumour lesions. {sup 18}F-dopa tumour uptake and the levels of biochemical tumour markers are mediated by tumour endocrine metabolic activity. We evaluated whether total {sup 18}F-dopa tumour uptake on PET, defined as whole-body metabolic tumour burden (WBMTB), reflects tumour load per patient, as measured with tumour markers. Seventy-seven consecutive carcinoid patients who underwent an {sup 18}F-dopa PET scan in two previously published studies were analysed. For all tumour lesions mean standardised uptake values (SUVs) at 40% of the maximal SUV and tumour volume on {sup 18}F-dopa PET were determined and multiplied to calculate a metabolic burden per lesion. WBMTB was the sum of the metabolic burden of all individual lesions per patient. The 24-h urinary serotonin, urine and plasma 5-hydroxindoleacetic acid (5-HIAA), catecholamines (nor)epinephrine, dopamine and their metabolites, measured in urine and plasma, and serum chromogranin A served as tumour markers. All but 1 were evaluable for WBMTB; 74 patients had metastatic disease. {sup 18}F-dopa PET detected 979 lesions. SUV{sub max} on {sup 18}F-dopa PET varied up to 29-fold between individual lesions within the same patients. WBMTB correlated with urinary serotonin (r = 0.51) and urinary and plasma 5-HIAA (r = 0.78 and 0.66). WBMTB also correlated with urinary norepinephrine, epinephrine, dopamine and plasma dopamine, but not with serum chromogranin A. Tumour load per patient measured with {sup 18}F-dopa PET correlates with tumour markers of the serotonin and catecholamine pathway in urine and plasma in carcinoid patients, reflecting metabolic tumour activity. (orig.)

  16. A new methodology for inter- and intrafraction plan adaptation for the MR-linac

    International Nuclear Information System (INIS)

    Kontaxis, C; Bol, G H; Lagendijk, J J W; Raaymakers, B W

    2015-01-01

    The new era of hybrid MRI and linear accelerator machines, including the MR-linac currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to provide the actual anatomy and real-time anatomy changes of the patient’s target(s) and organ(s) at risk (OARs) during radiation delivery. In order to be able to take advantage of this input, a new generation of treatment planning systems is needed, that will allow plan adaptation to the latest anatomy state in an online regime. In this paper, we present a treatment planning algorithm for intensity-modulated radiotherapy (IMRT), which is able to compensate for patient anatomy changes. The system consists of an iterative sequencing loop open to anatomy updates and an inter- and intrafraction adaptation scheme that enables convergence to the ideal dose distribution without the need of a final segment weight optimization (SWO). The ability of the system to take into account organ motion and adapt the plan to the latest anatomy state is illustrated using artificial baseline shifts created for three different kidney cases. Firstly, for two kidney cases of different target volumes, we show that the system can account for intrafraction motion, delivering the intended dose to the target with minimal dose deposition to the surroundings compared to conventional plans. Secondly, for a third kidney case we show that our algorithm combined with the interfraction scheme can be used to deliver the prescribed dose while adapting to the changing anatomy during multi-fraction treatments without performing a final SWO. (paper)

  17. A new methodology for inter- and intrafraction plan adaptation for the MR-linac

    Science.gov (United States)

    Kontaxis, C.; Bol, G. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2015-10-01

    The new era of hybrid MRI and linear accelerator machines, including the MR-linac currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to provide the actual anatomy and real-time anatomy changes of the patient’s target(s) and organ(s) at risk (OARs) during radiation delivery. In order to be able to take advantage of this input, a new generation of treatment planning systems is needed, that will allow plan adaptation to the latest anatomy state in an online regime. In this paper, we present a treatment planning algorithm for intensity-modulated radiotherapy (IMRT), which is able to compensate for patient anatomy changes. The system consists of an iterative sequencing loop open to anatomy updates and an inter- and intrafraction adaptation scheme that enables convergence to the ideal dose distribution without the need of a final segment weight optimization (SWO). The ability of the system to take into account organ motion and adapt the plan to the latest anatomy state is illustrated using artificial baseline shifts created for three different kidney cases. Firstly, for two kidney cases of different target volumes, we show that the system can account for intrafraction motion, delivering the intended dose to the target with minimal dose deposition to the surroundings compared to conventional plans. Secondly, for a third kidney case we show that our algorithm combined with the interfraction scheme can be used to deliver the prescribed dose while adapting to the changing anatomy during multi-fraction treatments without performing a final SWO.

  18. Oxidative stress specifically downregulates survivin to promote breast tumour formation.

    Science.gov (United States)

    Pervin, S; Tran, L; Urman, R; Braga, M; Parveen, M; Li, S A; Chaudhuri, G; Singh, R

    2013-03-05

    Breast cancer, a heterogeneous disease has been broadly classified into oestrogen receptor positive (ER+) or oestrogen receptor negative (ER-) tumour types. Each of these tumours is dependent on specific signalling pathways for their progression. While high levels of survivin, an anti-apoptotic protein, increases aggressive behaviour in ER- breast tumours, oxidative stress (OS) promotes the progression of ER+ breast tumours. Mechanisms and molecular targets by which OS promotes tumourigenesis remain poorly understood. DETA-NONOate, a nitric oxide (NO)-donor induces OS in breast cancer cell lines by early re-localisation and downregulation of cellular survivin. Using in vivo models of HMLE(HRAS) xenografts and E2-induced breast tumours in ACI rats, we demonstrate that high OS downregulates survivin during initiation of tumourigenesis. Overexpression of survivin in HMLE(HRAS) cells led to a significant delay in tumour initiation and tumour volume in nude mice. This inverse relationship between survivin and OS was also observed in ER+ human breast tumours. We also demonstrate an upregulation of NADPH oxidase-1 (NOX1) and its activating protein p67, which are novel markers of OS in E2-induced tumours in ACI rats and as well as in ER+ human breast tumours. Our data, therefore, suggest that downregulation of survivin could be an important early event by which OS initiates breast tumour formation.

  19. Volumetric modulated arc therapy for spine SBRT patients to reduce treatment time and intrafractional motion

    Directory of Open Access Journals (Sweden)

    Ahmad Amoush

    2015-01-01

    Full Text Available Volumetric modulated arc therapy (VMAT is an efficient technique to reduce the treatment time and intrafractional motion to treat spine patients presented with severe back pain. Five patients treated with spine stereotactic body radiation therapy (SBRT using 9 beams intensity modulated radiation therapy (IMRT were retrospectively selected for this study. The patients were replanned using two arcs VMAT technique. The average mean dose was 104% ± 1.2% and 104.1% ± 1.0% in IMRT and VMAT, respectively (p = 0.9. Accordingly, the average conformal index (CI was 1.3 ± 0.1 and 1.5 ± 0.3, respectively (p = 0.5. The average dose gradient (DG distance was 1.5 ± 0.1 cm and 1.4 ± 0.1 cm, respectively (p = 0.3. The average spinal cord maximum dose was 11.6 ± 1.0 Gy and 11.8 ± 1.1 Gy (p = 0.8 and V10Gy was 7.4 ± 1.4 cc and 8.6 ± 1.7 cc (p = 0.4 for IMRT and VMAT, respectively. Accordingly, the average number of monitor units (MUs was 6771.7 ± 1323.3 MU and 3978 ± 576.7 MU respectively (p = 0.02. The use of VMAT for spine SBRT patients with severe back pain can reduce the treatment time and intrafractional motion.

  20. MRI of pineal region tumours: relationship between tumours and adjacent structures

    International Nuclear Information System (INIS)

    Satoh, H.; Kurisu, K.

    1995-01-01

    A variety of tumours may arise in the pineal region; accurate diagnosis is important in the selection of treatment and prognosis. A retrospective analysis of the MRI studies of 25 patients with pathologically proven pineal region tumours was performed, focused on the relationship between the tumour and neighbouring structures. Compression of the tectal plate was classified as expansive or invasive, and compression of the corpus callosum as inferior, anterior or posterior. In 10 of the 14 patients (71 %) with germ cell tumours tectal compression was of the invasive type; 8 patients (57 %) had multiple tumours and in 13 (93 %) the tumour margins were irregular. Teratomas were readily diagnosed because of characteristic heterogeneous signal intensity. Pineal cell tumours were differentiated from germ cell tumours by their rounded shape, solid nature, sharp margins, and expansive type of tectal compression. Meningiomas were characterised by their falcotentorial attachments, posterior callosal compression, and a low-intensity rim on T2-weighted images. Gd-DTPA injection enabled clear demonstration of the site and extent of tumour spread and was useful in differentiating cystic and solid components. The appearances described, while not pathognomonic, are helpful in the differential diagnosis of pineal region tumours, and valuable in planning appropriate treatment. (orig.). With 4 figs., 6 tabs

  1. First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

    International Nuclear Information System (INIS)

    Deutschmann, Heinz; Kametriser, Gerhard; Steininger, Philipp; Scherer, Philipp; Schöller, Helmut; Gaisberger, Christoph; Mooslechner, Michaela; Mitterlechner, Bernhard; Weichenberger, Harald; Fastner, Gert; Wurstbauer, Karl; Jeschke, Stephan; Forstner, Rosemarie; Sedlmayer, Felix

    2012-01-01

    Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume–planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3° (mean of means), standard deviation of means ±4.9°, maximum at 30.7°. Three-dimensional vector translations relative to skin markings were 9.3 ± 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 ± 1.5 min (maximum, 15.1 min) between kV imaging and last beam’s electronic portal images showed further L-R rotations of 2.5° ± 2.3° (maximum, 26.9°), and three-dimensional vector translations of 3.0 ±3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard

  2. First clinical release of an online, adaptive, aperture-based image-guided radiotherapy strategy in intensity-modulated radiotherapy to correct for inter- and intrafractional rotations of the prostate.

    Science.gov (United States)

    Deutschmann, Heinz; Kametriser, Gerhard; Steininger, Philipp; Scherer, Philipp; Schöller, Helmut; Gaisberger, Christoph; Mooslechner, Michaela; Mitterlechner, Bernhard; Weichenberger, Harald; Fastner, Gert; Wurstbauer, Karl; Jeschke, Stephan; Forstner, Rosemarie; Sedlmayer, Felix

    2012-08-01

    We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3° (mean of means), standard deviation of means ±4.9°, maximum at 30.7°. Three-dimensional vector translations relative to skin markings were 9.3 ± 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 ± 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5° ± 2.3° (maximum, 26.9°), and three-dimensional vector translations of 3.0 ±3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of

  3. Study of Inter- and Intra-fraction Motion in Brain Tumor Patients Undergoing VMAT Treatment

    International Nuclear Information System (INIS)

    Ascencion Ybarra, Y.; Alfonso Laguardia, R.; Yartsev, S.

    2015-01-01

    Conforming dose to the tumor and sparing normal tissue can be challenging for brain tumors with complex shapes in close proximity to critical structures. The goal of this study was to evaluate the inter- and intra-fraction motion in brain tumor patients undergoing volumetric modulated arc therapy (VMAT). The image matching software was found to be very sensitive to the choice of the region of matching. It is recommended to use the same region of interest for comparing the image sets and perform the automatic matching based on bony landmarks in brain tumor cases. (Author)

  4. TUMOUR VACCINE

    NARCIS (Netherlands)

    Wagner, Ernst; Kircheis, Ralf; Crommelin, D.; Van Slooten, Maaike; Storm, Gert

    1999-01-01

    The invention relates to a tumour vaccine with a tumour antigen base. In addition to a source of tumour antigens, the vaccine contains a release system for the delayed release of the active agent IFN- gamma , the active dose of IFN- gamma being 50 ng to 5 mu g. The IFN- gamma is released over a

  5. Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.

    Science.gov (United States)

    Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P

    2007-06-01

    To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.

  6. X-ray-assisted positioning of patients treated by conformal arc radiotherapy for prostate cancer: Comparison of setup accuracy using implanted markers versus bony structures

    International Nuclear Information System (INIS)

    Soete, Guy; Cock, Mieke de; Verellen, Dirk; Michielsen, Dirk; Keuppens, Frans; Storme, Guy

    2007-01-01

    Purpose: The aim of this study was to compare setup accuracy of NovalisBody stereoscopic X-ray positioning using implanted markers in the prostate vs. bony structures in patients treated with dynamic conformal arc radiotherapy for prostate cancer. Methods and Materials: Random and systematic setup errors (RE and SE) of the isocenter with regard to the center of gravity of three fiducial markers were measured by means of orthogonal verification films in 120 treatment sessions in 12 patients. Positioning was performed using NovalisBody semiautomated marker fusion. The results were compared with a control group of 261 measurements in 15 patients who were positioned with NovalisBody automated bone fusion. In addition, interfraction and intrafraction prostate motion was registered in the patients with implanted markers. Results: Marker-based X-ray positioning resulted in a reduction of RE as well as SE in the anteroposterior, craniocaudal, and left-right directions compared with those in the control group. The interfraction prostate displacements with regard to the bony pelvis that could be avoided by marker positioning ranged between 1.6 and 2.8 mm for RE and between 1.3 and 4.3 mm for SE. Intrafraction random and systematic prostate movements ranged between 1.4 and 2.4 mm and between 0.8 and 1.3 mm, respectively. Conclusion: The problem of interfraction prostate motion can be solved by using implanted markers. In addition, the NovalisBody X-ray system performs more accurately with markers compared with bone fusion. Intrafraction organ motion has become the limiting factor for margin reduction around the clinical target volume

  7. Lymphatic vessels assessment in feline mammary tumours

    International Nuclear Information System (INIS)

    Sarli, Giuseppe; Sassi, Francesco; Brunetti, Barbara; Rizzo, Antonio; Diracca, Laura; Benazzi, Cinzia

    2007-01-01

    The lymphatic vessels play a crucial role in a variety of human cancers since tumour cell lymphatic invasion significantly influences prognosis. It is not known if pre-existing lymphatics are enough for tumour dissemination or de novo development is necessary. VEGFR-3 is an angiogenetic mediator for both lymphatic and blood vessels during embryonic development, and only for lymphatics after birth. VEGF is a mediator of both vasculogenesis and angiogenesis, regulates the growth of lymphatics in various experimental models, and is produced in many solid tumours. CD44 mediates hyaluronic acid (HA)-dependent cell adhesion: besides promoting invasion, this interaction also supports neoangiogenesis that indirectly stimulates tumour cell proliferation. The expression of VEGF-C (Vascular Endothelial Growth Factor – C), its receptor VEGFR-3 and CD44, were studied on feline mammary samples to assess the importance of lymphangiogenesis and lymphangiotrophism in neoplasia. Samples were taken from six normal mammary glands (NMG), ten benign (BT) and 32 malignant (MT) tumours. Immunohistochemical laminin/VEGFR-3 double stain, VEGF-C and CD44 stains were applied to 4 μm-thick sections, and their expression evaluated in intratumoral/extratumoral and intramammary/extramammary fields. All groups revealed a higher number of lymphatics in the extratumoral/extramammary areas. VEGF-C expression in the epithelium paralleled the number of positive vessels in the NMG, BT and MT, whereas VEGF-C higher expression was noted in the intratumoral fields only in infiltrating MT. CD44 score was lower in extratumoral than intratumoral fields in tumours and showed a significant increase in extramammary/extratumoral fields from NMG to MT. Pearson test showed a significant and inversely proportional correlation between CD44 expression and the number of lymphatic vessels with VEGFR-3 in malignant infiltrating tumours. The number of both VEGFR-3 positive and negative lymphatics in the extratumoral

  8. Clinical value of imaging using antibody to alpha fetoprotein in germ cell tumours

    International Nuclear Information System (INIS)

    Hitchins, R.N.; Begent, R.H.J.; Green, A.J.; Searle, F.; Bagshawe, K.D.; Charing Cross Group of Hospitals, London; Van Heyningen, V.

    1989-01-01

    Germ cell tumours (GCT) producing alpha fetoprotein (aFP) can be imaged by external scintigraphy after intraveneous administration of radiolabelled antibody directed against aFP. Antibody imaging (AI) by this method was used in an attempt to guide surgical resection of deposits of drug-resistant or recurrent GCT. 30 patients with GCT and raised aFP in whom site of tumour was not known were investigated by AI and conventional imaging methods. All but one were heavily pretreated. Where tumour appeared localised, resection was attempted. Tumour was found in all sites positive by both AI and conventional imaging. AI produced false-positive results in one of 30 patients and false-negative results in 9 patients. Computerised tomography was false-positive in one case and false-negative in three. In these patients, AI gave true-negative and true-positive results, respectively. Of 11 patients with positive AI in whom resection was attempted, 6 achieved sustained complete response with up to 5 years follow-up. We conclude AI and conventional imaging methods to be complementary in selection for surgery of patients with drug-resistant or recurrent GCT. (orig.) [de

  9. Low tumour cell content in a lung tumour bank: implications for molecular characterisation.

    Science.gov (United States)

    Goh, Felicia; Duhig, Edwina E; Clarke, Belinda E; McCaul, Elizabeth; Passmore, Linda; Courtney, Deborah; Windsor, Morgan; Naidoo, Rishendren; Franz, Louise; Parsonson, Kylie; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2017-10-01

    Lung cancer encompasses multiple malignant epithelial tumour types, each with specific targetable, potentially actionable mutations, such that precision management mandates accurate tumour typing. Molecular characterisation studies require high tumour cell content and low necrosis content, yet lung cancers are frequently a heterogeneous mixture of tumour and stromal cells. We hypothesised that there may be systematic differences in tumour cell content according to histological subtype, and that this may have implications for tumour banks as a resource for comprehensive molecular characterisation studies in lung cancer. To investigate this, we estimated tumour cell and necrosis content of 4267 samples resected from 752 primary lung tumour specimens contributed to a lung tissue bank. We found that banked lung cancer samples had low tumour cell content (33%) generally, although it was higher in carcinoids (77.5%) than other lung cancer subtypes. Tumour cells comprise a variable and often small component of banked resected tumour samples, and are accompanied by stromal reaction, inflammation, fibrosis, and normal structures. This has implications for the adequacy of unselected tumour bank samples for diagnostic and molecular investigations, and further research is needed to determine whether tumour cell content has a significant impact on analytical results in studies using tissue from tumour bank resources. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  10. Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy.

    Science.gov (United States)

    Zhang, Yawei; Deng, Xinchen; Yin, Fang-Fang; Ren, Lei

    2018-01-01

    Limited-angle intrafraction verification (LIVE) has been previously developed for four-dimensional (4D) intrafraction target verification either during arc delivery or between three-dimensional (3D)/IMRT beams. Preliminary studies showed that LIVE can accurately estimate the target volume using kV/MV projections acquired over orthogonal view 30° scan angles. Currently, the LIVE imaging acquisition requires slow gantry rotation and is not clinically optimized. The goal of this study is to optimize the image acquisition parameters of LIVE for different patient respiratory periods and gantry rotation speeds for the effective clinical implementation of the system. Limited-angle intrafraction verification imaging acquisition was optimized using a digital anthropomorphic phantom (XCAT) with simulated respiratory periods varying from 3 s to 6 s and gantry rotation speeds varying from 1°/s to 6°/s. LIVE scanning time was optimized by minimizing the number of respiratory cycles needed for the four-dimensional scan, and imaging dose was optimized by minimizing the number of kV and MV projections needed for four-dimensional estimation. The estimation accuracy was evaluated by calculating both the center-of-mass-shift (COMS) and three-dimensional volume-percentage-difference (VPD) between the tumor in estimated images and the ground truth images. The robustness of LIVE was evaluated with varied respiratory patterns, tumor sizes, and tumor locations in XCAT simulation. A dynamic thoracic phantom (CIRS) was used to further validate the optimized imaging schemes from XCAT study with changes of respiratory patterns, tumor sizes, and imaging scanning directions. Respiratory periods, gantry rotation speeds, number of respiratory cycles scanned and number of kV/MV projections acquired were all positively correlated with the estimation accuracy of LIVE. Faster gantry rotation speed or longer respiratory period allowed less respiratory cycles to be scanned and less kV/MV projections

  11. An imbalance in progenitor cell populations reflects tumour progression in breast cancer primary culture models

    LENUS (Irish Health Repository)

    Donatello, Simona

    2011-04-26

    Abstract Background Many factors influence breast cancer progression, including the ability of progenitor cells to sustain or increase net tumour cell numbers. Our aim was to define whether alterations in putative progenitor populations could predict clinicopathological factors of prognostic importance for cancer progression. Methods Primary cultures were established from human breast tumour and adjacent non-tumour tissue. Putative progenitor cell populations were isolated based on co-expression or concomitant absence of the epithelial and myoepithelial markers EPCAM and CALLA respectively. Results Significant reductions in cellular senescence were observed in tumour versus non-tumour cultures, accompanied by a stepwise increase in proliferation:senescence ratios. A novel correlation between tumour aggressiveness and an imbalance of putative progenitor subpopulations was also observed. Specifically, an increased double-negative (DN) to double-positive (DP) ratio distinguished aggressive tumours of high grade, estrogen receptor-negativity or HER2-positivity. The DN:DP ratio was also higher in malignant MDA-MB-231 cells relative to non-tumourogenic MCF-10A cells. Ultrastructural analysis of the DN subpopulation in an invasive tumour culture revealed enrichment in lipofuscin bodies, markers of ageing or senescent cells. Conclusions Our results suggest that an imbalance in tumour progenitor subpopulations imbalances the functional relationship between proliferation and senescence, creating a microenvironment favouring tumour progression.

  12. Automatic tumour volume delineation in respiratory-gated PET images

    International Nuclear Information System (INIS)

    Gubbi, Jayavardhana; Palaniswami, Marimuthu; Kanakatte, Aparna; Mani, Nallasamy; Kron, Tomas; Binns, David; Srinivasan, Bala

    2011-01-01

    Positron emission tomography (PET) is a state-of-the-art functional imaging technique used in the accurate detection of cancer. The main problem with the tumours present in the lungs is that they are non-stationary during each respiratory cycle. Tumours in the lungs can get displaced up to 2.5 cm during respiration. Accurate detection of the tumour enables avoiding the addition of extra margin around the tumour that is usually used during radiotherapy treatment planning. This paper presents a novel method to detect and track tumour in respiratory-gated PET images. The approach followed to achieve this task is to automatically delineate the tumour from the first frame using support vector machines. The resulting volume and position information from the first frame is used in tracking its motion in the subsequent frames with the help of level set (LS) deformable model. An excellent accuracy of 97% is obtained using wavelets and support vector machines. The volume calculated as a result of the machine learning (ML) stage is used as a constraint for deformable models and the tumour is tracked in the remaining seven phases of the respiratory cycle. As a result, the complete information about tumour movement during each respiratory cycle is available in relatively short time. The combination of the LS and ML approach accurately delineated the tumour volume from all frames, thereby providing a scope of using PET images towards planning an accurate and effective radiotherapy treatment for lung cancer.

  13. TH-A-BRF-04: Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI

    International Nuclear Information System (INIS)

    Kleijnen, J; Asselen, B; Burbach, M; Intven, M; Reerink, O; Philippens, M; Lagendijk, J; Raaymakers, B

    2014-01-01

    Purpose: To investigate the intra-fraction motion in patients with early stage rectal cancer using cine-MRI. Methods: Sixteen patient diagnosed with early stage rectal cancer underwent 1.5 T MR imaging prior to each treatment fraction of their short course radiotherapy (n=76). During each scan session, three 2D sagittal cine-MRIs were performed: at the beginning (Start), after 9:30 minutes (Mid), and after 18 minutes (End). Each cine-MRI has a duration of one minute at 2Hz temporal resolution, resulting in a total of 3:48 hours of cine-MRI. Additionally, standard T2-weighted (T2w) imaging was performed. Clinical target volume (CTV) an tumor (GTV) were delineated on the T2w scan and transferred to the first time-point of each cine-MRI scan. Within each cine-MRI, the first frame was registered to the remaining frames of the scan, using a non-rigid B-spline registration. To investigate potential drifts, a similar registration was performed between the first frame of the Start and End scans.To evaluate the motion, the distances by which the edge pixels of the delineations move in anterior-posterior (AP) and cranial-caudal (CC) direction, were determined using the deformation field of the registrations. The distance which incorporated 95% of these edge pixels (dist95%) was determined within each cine-MRI, and between Start- End scans, respectively. Results: Within a cine-MRI, we observed an average dist95% for the CTV of 1.3mm/1.5mm (SD=0.7mm/0.6mm) and for the GTV of 1.2mm/1.5mm (SD=0.8mm/0.9mm), in respectively AP/CC. For the CTV motion between the Start and End scan, an average dist95% of 5.5mm/5.3mm (SD=3.1mm/2.5mm) was found, in respectively AP/CC. For the GTV motion, an average dist95% of 3.6mm/3.9mm (SD=2.2mm/2.5mm) was found in AP/CC, respectively. Conclusion: Although intra-fraction motion within a one minute cine-MRI is limited, substantial intra-fraction motion was observed within the 18 minute time period between the Start and End cine-MRI

  14. Immunity to tumour antigens.

    Science.gov (United States)

    Li, Geng; Ali, Selman A; McArdle, Stephanie E B; Mian, Shahid; Ahmad, Murrium; Miles, Amanda; Rees, Robert C

    2005-01-01

    During the last decade, a large number of human tumour antigens have been identified. These antigens are classified as tumour-specific shared antigens, tissue-specific differentiation antigens, overexpressed antigens, tumour antigens resulting from mutations, viral antigens and fusion proteins. Antigens recognised by effectors of immune system are potential targets for antigen-specific cancer immunotherapy. However, most tumour antigens are self-proteins and are generally of low immunogenicity and the immune response elicited towards these tumour antigens is not always effective. Strategies to induce and enhance the tumour antigen-specific response are needed. This review will summarise the approaches to discovery of tumour antigens, the current status of tumour antigens, and their potential application to cancer treatment.

  15. The development of tumours under a ketogenic diet in association with the novel tumour marker TKTL1: A case series in general practice.

    Science.gov (United States)

    Jansen, Natalie; Walach, Harald

    2016-01-01

    Since the initial observations by Warburg in 1924, it has become clear in recent years that tumour cells require a high level of glucose to proliferate. Therefore, a ketogenic diet that provides the body with energy mainly through fat and proteins, but contains a reduced amount of carbohydrates, has become a dietary option for supporting tumour treatment and has exhibited promising results. In the present study, the first case series of such a treatment in general practice is presented, in which 78 patients with tumours were treated within a time window of 10 months. The patients were monitored regarding their levels of transketolase-like-1 (TKTL1), a novel tumour marker associated with aerobic glycolysis of tumour cells, and the patients' degree of adherence to a ketogenic diet. Tumour progression was documented according to oncologists' reports. Tumour status was correlated with TKTL1 expression (Kruskal-Wallis test, Pketogenic diet, with one patient experiencing a stagnation in tumour progression and others an improvement in their condition. The adoption of a ketogenic diet was also observed to affect the levels of TKTL1 in those patients. In conclusion, the results from the present case series in general practice suggest that it may be beneficial to advise tumour patients to adopt a ketogenic diet, and that those who adhere to it may have positive results from this type of diet. Thus, the use of a ketogenic diet as a complementary treatment to tumour therapy must be further studied in rigorously controlled trials.

  16. Awake craniotomy and electrophysiological mapping for eloquent area tumours.

    Science.gov (United States)

    Chacko, Ari George; Thomas, Santhosh George; Babu, K Srinivasa; Daniel, Roy Thomas; Chacko, Geeta; Prabhu, Krishna; Cherian, Varghese; Korula, Grace

    2013-03-01

    An awake craniotomy facilitates radical excision of eloquent area gliomas and ensures neural integrity during the excision. The study describes our experience with 67 consecutive awake craniotomies for the excision of such tumours. Sixty-seven patients with gliomas in or adjacent to eloquent areas were included in this study. The patient was awake during the procedure and intraoperative cortical and white matter stimulation was performed to safely maximize the extent of surgical resection. Of the 883 patients who underwent craniotomies for supratentorial intraaxial tumours during the study period, 84 were chosen for an awake craniotomy. Sixty-seven with a histological diagnosis of glioma were included in this study. There were 55 men and 12 women with a median age of 34.6 years. Forty-two (62.6%) patients had positive localization on cortical stimulation. In 6 (8.9%) patients white matter stimulation was positive, five of whom had responses at the end of a radical excision. In 3 patients who developed a neurological deficit during tumour removal, white matter stimulation was negative and cessation of the surgery did not result in neurological improvement. Sixteen patients (24.6%) had intraoperative neurological deficits at the time of wound closure, 9 (13.4%) of whom had persistent mild neurological deficits at discharge, while the remaining 7 improved to normal. At a mean follow-up of 40.8 months, only 4 (5.9%) of these 9 patients had persistent neurological deficits. Awake craniotomy for excision of eloquent area gliomas enable accurate mapping of motor and language areas as well as continuous neurological monitoring during tumour removal. Furthermore, positive responses on white matter stimulation indicate close proximity of eloquent cortex and projection fibres. This should alert the surgeon to the possibility of postoperative deficits to change the surgical strategy. Thus the surgeon can resect tumour safely, with the knowledge that he has not damaged

  17. Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation

    International Nuclear Information System (INIS)

    Adamson, Justus; Wu Qiuwen

    2009-01-01

    Monoscopic kV imaging during radiotherapy has been recently implemented for prostate intrafraction motion evaluation. However, the accuracy of 3D localization techniques from monoscopic imaging of prostate and the effect of acquisition parameters on the 3D accuracy have not been studied in detail, with imaging dose remaining a concern. In this paper, we investigate methods to optimize the kV acquisition parameters and imaging protocol to achieve improved 3D localization and 2D image registration accuracy for minimal imaging dose. Prostate motion during radiotherapy was simulated using existing cine-MRI measurements, and was used to investigate the accuracy of various 3D localization techniques and the effect of the kV acquisition protocol. We also investigated the relationship between mAs and the accuracy of the 2D image registration for localization of fiducial markers and we measured imaging dose for a 30 cm diameter phantom to evaluate the necessary dose to achieve acceptable image registration accuracy. Simulations showed that the error in assuming the shortest path to localize the prostate in 3D using monoscopic imaging during a typical IMRT fraction will be less than ∼1.5 mm for 95% of localizations, and will also depend on prostate motion distribution, treatment duration and image acquisition and treatment protocol. Most uncertainty cannot be reduced from higher imaging frequency or acquiring during gantry rotation between beams. Measured maximum surface dose to the cylindrical phantom from monoscopic kV intrafraction acquisitions varied between 0.4 and 5.5 mGy, depending on the acquisition protocol, and was lower than the required dose for CBCT (21.1 mGy). Imaging dose can be lowered by ∼15-40% when mAs is optimized with acquisition angle. Images acquired during MV beam delivery require increased mAs to obtain the same level of registration accuracy, with mAs/registration increasing roughly linearly with field size and dose rate.

  18. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Igel, Todd C.; Gale, Ashley A.; Serago, Nicole E.; Earle, John D.

    2006-01-01

    Purpose: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. Methods and Materials: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. Results: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 ± 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 ± 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 ± 3.1 mm, and the average intrafraction movement during treatment is 3.4 ± 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 ± 1.5 mm, and the average intrafraction movement during treatment is 2.1 ± 1.5 mm. Conclusions: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization

  19. Tumour TIF1 mutations and loss of heterozygosity related to cancer-associated myositis.

    Science.gov (United States)

    Pinal-Fernandez, Iago; Ferrer-Fabregas, Berta; Trallero-Araguas, Ernesto; Balada, Eva; Martínez, Maria Angeles; Milisenda, Jose César; Aparicio-Español, Gloria; Labrador-Horrillo, Moises; Garcia-Patos, Vicente; Grau-Junyent, Josep M; Selva-O'Callaghan, Albert

    2018-02-01

    To analyse the influence of genetic alterations and differential expression of transcription intermediary factor 1 (TIF1) genes in the pathophysiology of cancer-associated myositis (CAM). Paired blood and tumour DNA samples from patients with anti-TIF1γ-positive CAM and from controls were analysed by whole-exome sequencing for the presence of somatic mutations and loss of heterozygosity (LOH) in their TIF1 genes. The genesis and maintenance of the autoimmune process were investigated immunohistochemically by studying TIF1γ expression in the different tissues involved in CAM (skin, muscle and tumour) based on the immunohistochemical H-score. From seven patients with anti-TIF1γ-positive CAM, we detected one somatic mutation and five cases of LOH in one or more of the four TIF1 genes compared with just one case of LOH in tumours from TIF1γ-negative myositis patients (86% vs 17%; P = 0.03). Compared with type-matched control tumours from non-myositis patients, TIF1γ staining was more intense in tumours from anti-TIF1γ-positive patients (H-score 255 vs 196; P = 0.01). Also, TIF1γ staining in muscle was slightly more intense in anti-TIF1γ-positive than in anti-TIF1γ-negative myositis (H-score 22 vs 5; P = 0.03). In contrast, intense TIF1γ staining was detected in the skin of both myositis and control patients. Tumours from paraneoplastic anti-TIF1γ-positive patients showed an increased number of genetic alterations, such as mutations and LOH, in TIF1 genes. These genetic alterations, in the context of a high expression of TIF1γ in the tumour, muscle and skin of these patients may be key to understanding the genesis of paraneoplastic myositis. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  20. PHOX2B reliably distinguishes neuroblastoma among small round blue cell tumours.

    Science.gov (United States)

    Hung, Yin P; Lee, John P; Bellizzi, Andrew M; Hornick, Jason L

    2017-11-01

    Neuroblastoma shows considerable histological overlap with other small round blue cell tumours. PHOX2B, a transcription factor that is essential for autonomic nervous system development, has been reported as an immunohistochemical marker for neuroblastoma. The aim of this study was to validate the specificity and diagnostic utility of PHOX2B for peripheral neuroblastic tumours. We evaluated 240 cases (133 in whole-tissue sections; 107 in tissue microarrays), including 76 peripheral neuroblastic tumours (median age 2 years; including four adults) and 164 other tumours: 44 Wilms tumours; 20 Ewing sarcomas; 10 each of CIC-rearranged round cell sarcomas, poorly differentiated synovial sarcomas, lymphoblastic lymphomas, alveolar rhabdomyosarcomas, embryonal rhabdomyosarcomas, mesenchymal chondrosarcomas, Merkel cell carcinomas, olfactory neuroblastomas, and melanomas; and five each of NUT midline carcinomas and desmoplastic small round cell tumours. Immunohistochemistry for PHOX2B was performed with a rabbit monoclonal antibody. PHOX2B positivity was defined as the presence of nuclear immunoreactivity in ≥5% of cells. PHOX2B was positive in 70 (92%) peripheral neuroblastic tumours, including 68 of 72 (94%) paediatric and two of four (50%) adult cases. Furthermore, PHOX2B was consistently negative in all non-peripheral neuroblastic tumours, with staining being absent in 160 cases and limited in four cases. PHOX2B is a highly sensitive and specific immunohistochemical marker for peripheral neuroblastic tumours, including neuroblastoma. PHOX2B reliably distinguishes neuroblastoma from histological mimics such as Wilms tumour, Ewing sarcoma, and CIC-rearranged round cell sarcoma. PHOX2B negativity in two of four adult neuroblastoma cases raises the possibility that some adult neuroblastomas are of a different lineage than paediatric cases. © 2017 John Wiley & Sons Ltd.

  1. Electrochemotherapy of tumours

    International Nuclear Information System (INIS)

    Sersa, G.; Cemazar, M.; Rudolf, Z.; Miklavcic, D.

    2006-01-01

    Electrochemotherapy consists of chemotherapy followed by local application of electric pulses to the tumour to increase drug delivery into cells. Drug uptake can be increased by electroporation for only those drugs whose transport through the plasma membrane is impeded. Among many drugs that have been tested so far, only bleomycin and cisplatin found their way from preclinical testing to clinical trials. In vitro studies demonstrated several fold increase of their cytotoxicity after electroporation of cells. In vivo, electroporation of tumours after local or systemic administration of either of the drugs, i.e. electrochemotherapy, proved to be an effective antitumour treatment. In preclinical studies on several tumour models, electrochemotherapy either with bleomycin or cisplatin was elaborated and parameters for effective local tumour control were determined. In veterinary medicine, electrochemotherapy also proved to be effective in the treatment of primary tumours in cats, dogs and horses. In human clinical studies, electrochemotherapy was performed on the patients with progressive disease and accessible tumour nodules of different malignancies. All clinical studies demonstrated that electrochemotherapy is an effective treatment for local tumour control in cancer patients. (author)

  2. Expression of p16(INK4A) gene in human pituitary tumours.

    Science.gov (United States)

    Machiavelli, Gloria; Cotignola, Javier; Danilowicz, Karina; Carbonara, Carolina; Paes de Lima, Andrea; Basso, Armando; Bruno, Oscar Domingo; Szijan, Irene

    2008-01-01

    Pituitary adenomas comprise 10-15% of primary intracranial tumours but the mechanisms leading to tumour development are yet to be clearly established. The retinoblastoma pathway, which regulates the progression through the cell cycle, is often deregulated in different types of tumours. We studied the cyclin-dependent kinase inhibitor p16(INK4A) gene expression at mRNA level in human pituitary adenomas. Forty-six tumour specimens of different subtypes, 21 clinically non-functioning, 12 growth hormone-secreting, 6 prolactin-secreting, 6 adrenocorticotropin-secreting, and 1 thyrotropin-secreting tumours were studied. All clinically non-functioning and most of the hormone-secreting tumours were macroadenomas (38/46). The RT-PCR assay and electrophoresis of the PCR-products showed that p16(INK4A) mRNA was undetectable in: 62% of non-functioning, 8% of growth hormone-secreting, 17% of prolactin-secreting and 17% of adrenocorticotropin-secreting adenomas. Forty percent of all macroadenomas and 25% of microadenomas had negative p16(INK4A) mRNA, the latter results suggest that the absence of p16(INK4A) product might be an early event in tumours with no expression of this suppressor gene. Within the non-functioning adenomas 63% were "null cell" and 37% were positive for some hormone, both subgroups showed similar percentage of cases with absence of p16(INK4A) mRNA. Our results show that clinically non-functioning macroadenomas have impaired p16(INK4A) expression in a clearly higher proportion than any other pituitary tumour subtype investigated. Other regulatory pathways may be implicated in the development of tumours with positive p16(INK4A) expression.

  3. Gastric Calcifying Fibrous Tumour

    Directory of Open Access Journals (Sweden)

    Tan Attila

    2006-01-01

    Full Text Available Intramucosal gastric tumours are most commonly found to be gastrointestinal stromal tumours or leiomyomas (smooth muscle tumours; however, a variety of other uncommon mesenchymal tumours can occur in the stomach wall. A rare benign calcifying fibrous tumour is reported and the endoscopic appearance, ultrasound findings and morphology are documented. A review of the literature found only two similar cases.

  4. 99mTc-GHA: A promising agent for assessing tumour viability

    International Nuclear Information System (INIS)

    Choudhury, P.S.; Gupta, A.; Sharma, P.K.; Bhatia, S.; Nambiar, U.; Jena, A.

    2004-01-01

    Full text: Biochemical investigations have a major role to play in the management of primary malignancies. Major biochemical changes occur during cancerous transformation including changes in the energy metabolism of the cell. Changes can take place in terms of utilization of glucose and other substrates, protein synthesis and expression of antigens and receptors. Changes also take place in disruption of transport mechanism across cell membranes and other physiological boundaries like blood brain barrier. Anatomical imaging is aimed at the diagnosis of tumours whereas biochemical imaging is better suited for tissue characterization. We report here the utility of 99mTc GHA as a radiopharmaceutical for assessing tumour viability. Evaluation was done for 44 patients who had undergone 72 studies based on objective parameters like histopathological correlation and serial clinical and other radiological evaluation in long-term follow-up. All the evaluated patients had undergone magnetic resonance imaging (MRI) of the local site within one week of 99m GHA study and had some sort of morphological abnormality and suspicious contrast behaviour. 41 patients had cerebral lesions (37 primary brain tumours during initial diagnosis, evaluation of residual or recurrent disease and 4 patients of brain metastasis) and 3 patients had Ewing's Sarcoma evaluated during the course of treatment. 29 patients of suspected brain tumour (21 primary and 8 residual / recurrence) had surgical decompression along with 2/4 in metastatic brain lesions. Out of the 29 patients who underwent surgery, 28 patients had histopathology positive for malignancy. 27 patients showed abnormal GHA concentration corresponding to the morphological abnormality (1 false negative). One patient of pseudo-tumour also showed avid tracer concentration (false positive). 2/4 patients of solitary metastatic foci in brain, with positive GHA scan, underwent surgery and showed positive histopathology. 2/4 patients treated by

  5. Over-all accuracy of sup(99m)Tc-pertechnetate brain scanning for brain tumours

    International Nuclear Information System (INIS)

    Bjoernsson, O.G.; Petursson, E.; Sigurbjoernsson, B.; Davidsson, D.

    1978-01-01

    A 3-year follow-up and re-evaluation of all scans on all patients referred for brain scanning in Iceland during 1 year was performed in order to assess the diagnostic reliability of radioisotope scanning for brain tumours. The study included 471 patients. Of these 25 had primary brain tumours and 7 brain metastases. Scans were positive and correctly interpreted in 68% of the patients with primary brain tumours and in 3 of the 7 patients with metastases. The over-all accuracy of brain scanning for brain tumours defined as the total number of correct positive scans and correct negative scans versus total number of scans examined was 96%, this figure being mainly influenced by the high number of true negative scans. (orig.) [de

  6. Tumour-induced osteomalacia.

    Science.gov (United States)

    Minisola, Salvatore; Peacock, Munro; Fukumoto, Seijii; Cipriani, Cristiana; Pepe, Jessica; Tella, Sri Harsha; Collins, Michael T

    2017-07-13

    Tumour-induced osteomalacia (TIO), also known as oncogenic osteomalacia, is a rare paraneoplastic disorder caused by tumours that secrete fibroblast growth factor 23 (FGF23). Owing to the role of FGF23 in renal phosphate handling and vitamin D synthesis, TIO is characterized by decreased renal tubular reabsorption of phosphate, by hypophosphataemia and by low levels of active vitamin D. Chronic hypophosphataemia ultimately results in osteomalacia (that is, inadequate bone mineralization). The diagnosis of TIO is usually suspected when serum phosphate levels are chronically low in the setting of bone pain, fragility fractures and muscle weakness. Locating the offending tumour can be very difficult, as the tumour is often very small and can be anywhere in the body. Surgical removal of the tumour is the only definitive treatment. When the tumour cannot be located or when complete resection is not possible, medical treatment with phosphate salts or active vitamin D is necessary. One of the most promising emerging treatments for unresectable tumours that cause TIO is the anti-FGF23 monoclonal antibody KRN23. The recent identification of a fusion of fibronectin and fibroblast growth factor receptor 1 (FGFR1) as a molecular driver in some tumours not only sheds light on the pathophysiology of TIO but also opens the door to a better understanding of the transcription, translocation, post-translational modification and secretion of FGF23, as well as suggesting approaches to targeted therapy. Further study will reveal if the FGFR1 pathway is also involved in tumours that do not harbour the translocation.

  7. Adnexal Tumours Of Skin

    Directory of Open Access Journals (Sweden)

    Parate Sanjay N

    1998-01-01

    Full Text Available A total 120 cases of epidermal appendage tumours of skin were analysed and classified according to the classification provided by WHO’. Epidermal appendage tumours accounted for 12.87% of all skin tumours, of which 29.17% were benign and 70.83% were malignant. Most of the tumours (75.83% were in the head and face region. The most common tumour was basal cell epithelioma (55%.

  8. Inhibitory effects of CP on the growth of human gastric adenocarcinoma BGC-823 tumours in nude mice.

    Science.gov (United States)

    Wang, Hai-Jun; Liu, Yu; Zhou, Bao-Jun; Zhang, Zhan-Xue; Li, Ai-Ying; An, Ran; Yue, Bin; Fan, Li-Qiao; Li, Yong

    2018-05-01

    Objective To investigate the potential antitumour effects of [2-(6-amino-purine-9-yl)-1-hydroxy-phosphine acyl ethyl] phosphonic acid (CP) against gastric adenocarcinoma. Methods Human BGC-823 xenotransplants were established in nude mice. Animals were randomly divided into control and CP groups, which were administered NaHCO 3 vehicle alone or CP dissolved in NaHCO 3 (200 µg/kg body weight) daily, respectively. Tumour volume was measured weekly for 6 weeks. Resected tumours were assayed for proliferative activity with anti-Ki-67 or anti-proliferating cell nuclear antigen (PCNA) antibodies. Cell apoptosis was examined using terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling (TUNEL) assays and with caspase-3 immunostaining. Proteins were measured by Western blotting. Results There was a significant reduction in tumour volume and a reduced percentage of Ki-67-positive or PCNA-positive cells in the CP group compared with the control group. The percentage of TUNEL-positive or caspase 3-positive cells significantly increased following CP treatment compared with the control group. Tumours from the CP group had higher levels of phosphorylated-extracellular signal-regulated kinase (p-ERK) and phosphorylated-AKT (p-AKT) compared with control tumours. Conclusion CP treatment inhibited tumour growth and induced tumour cell apoptosis in a nude mouse model of BGC-823 gastric adenocarcinoma. Activation of the AKT and ERK signalling pathways may mediate this antitumour activity.

  9. MRT in differentiation between tumour and implant material in the postoperative sella

    International Nuclear Information System (INIS)

    Kaiser, W.A.; Steckelbroeck, V.; Siewert, B.; Layer, G.; Hochstetter, A.; Reiser, M.

    1993-01-01

    MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T 1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for hypophyseal tumours to evaluate the success of surgery and where there is clinical doubt concerning residual or recurrent tumour. (orig.) [de

  10. Heat shock protein expression in canine malignant mammary tumours

    International Nuclear Information System (INIS)

    Romanucci, Mariarita; Marinelli, Alessia; Sarli, Giuseppe; Salda, Leonardo Della

    2006-01-01

    Abnormal levels of Heat Shock Proteins (HSPs) have been observed in many human neoplasms including breast cancer and it has been demonstrated that they have both prognostic and therapeutic implications. In this study, we evaluated immunohistochemical expression of HSPs in normal and neoplastic canine mammary glands and confronted these results with overall survival (OS), in order to understand the role of HSPs in carcinogenesis and to establish their potential prognostic and/or therapeutic value. Immunohistochemical expression of Hsp27, Hsp72, Hsp73 and Hsp90 was evaluated in 3 normal canine mammary glands and 30 malignant mammary tumours (10 in situ carcinomas, 10 invasive carcinomas limited to local structures without identifiable invasion of blood or lymphatic vessels, 10 carcinomas with invasion of blood or lymphatic vessels and/or metastases to regional lymph nodes). A semi-quantitative method was used for the analysis of the results. Widespread constitutive expression of Hsp73 and Hsp90 was detected in normal tissue, Hsp72 appeared to be focally distributed and Hsp27 showed a negative to rare weak immunostaining. In mammary tumours, a significant increase in Hsp27 (P < 0.01), Hsp72 (P < 0.05) and Hsp90 (P < 0.01) expression was observed as well as a significant reduction in Hsp73 (P < 0.01) immunoreactivity compared to normal mammary gland tissue. Hsp27 demonstrated a strong positivity in infiltrating tumour cells and metaplastic squamous elements of invasive groups. High Hsp27 expression also appeared to be significantly correlated to a shorter OS (P = 0.00087). Intense immunolabelling of Hsp72 and Hsp73 was frequently detected in infiltrative or inflammatory tumour areas. Hsp90 expression was high in all tumours and, like Hsp73, it also showed an intense positivity in lymphatic emboli. These results suggest that Hsp27, Hsp72 and Hsp90 are involved in canine mammary gland carcinogenesis. In addition, Hsp27 appears to be implicated in tumour invasiveness and

  11. Interleukin 21 controls tumour growth and tumour immunosurveillance in colitis-associated tumorigenesis in mice.

    Science.gov (United States)

    Jauch, Dominik; Martin, Maria; Schiechl, Gabriela; Kesselring, Rebecca; Schlitt, Hans Jürgen; Geissler, Edward K; Fichtner-Feigl, Stefan

    2011-12-01

    Colitis-associated tumorigenesis is a balance between proliferation of tumour cells and tumour immunosurveillance. The role of T-helper-cell-derived cytokines in tumour growth is not fully understood. In this study the authors investigated the influence of interleukin (IL) 21 on intestinal tumorigenesis. Chronic colitis was induced in IL-21(-/-) and littermate control wild-type mice with three cycles of 1.5% dextran sulphate sodium (DSS) over 7 days followed by 7 days of drinking water. Mice received an azoxymethane injection on day 0 of DSS-colitis to induce tumorigenesis. Immunohistochemistry was performed on inflamed and tumour-bearing areas of colons. Cytokine expression of isolated colonic CD4 T cells was determined by ELISA. Cytotoxic capacity of isolated colonic CD8 T cells targeting tumour cells was evaluated by flow cytometry and quantitative cytotoxicity assay. Apoptosis of tumour cells was determined by TUNEL assay of colonic sections. Increasing expression of IL-21 was observed in chronic colitis, which showed functional importance, since IL-21 deficiency prevented chronic DSS-colitis development. Further, in the absence of IL-21, significantly fewer tumour nodules were detected, despite a similar extent of intestinal inflammation. In wild-type mice, 8.6±1.9 tumour nodules were found compared with 1.0±1.2 in IL-21-deficient mice. In tumour-bearing IL-21-deficient mice, intestinal inflammation was restored and partly dependent on interferon (IFN)-γ, whereas the inflammation in wild-type mice showed high IL-17A concentrations. In these rare tumours in IL-21-deficient mice, tumour cell proliferation (Ki-67) was decreased, while cell apoptosis was increased, compared with wild-type mice. Increased IFNγ expression in tumour-bearing IL-21-deficient mice led to increased tumour immunosurveillance mediated by cytotoxic CD8CD103 T cells targeting E-cadherin(+) colonic tumour cells and therefore limited tumour growth. These results indicate that IL-21

  12. Tumour nuclear oestrogen receptor beta 1 correlates inversely with parathyroid tumour weight.

    Science.gov (United States)

    Haglund, Felix; Rosin, Gustaf; Nilsson, Inga-Lena; Juhlin, C Christofer; Pernow, Ylva; Norenstedt, Sophie; Dinets, Andrii; Larsson, Catharina; Hartman, Johan; Höög, Anders

    2015-03-01

    Primary hyperparathyroidism (PHPT) is a common endocrinopathy, frequently caused by a parathyroid adenoma, rarely by a parathyroid carcinoma that lacks effective oncological treatment. As the majority of cases are present in postmenopausal women, oestrogen signalling has been implicated in the tumourigenesis. Oestrogen receptor beta 1 (ERB1) and ERB2 have been recently identified in parathyroid adenomas, the former inducing genes coupled to tumour apoptosis. We applied immunohistochemistry and slide digitalisation to quantify nuclear ERB1 and ERB2 in 172 parathyroid adenomas, atypical adenomas and carcinomas, and ten normal parathyroid glands. All the normal parathyroid glands expressed ERB1 and ERB2. The majority of tumours expressed ERB1 (70.6%) at varying intensities, and ERB2 (96.5%) at strong intensities. Parathyroid carcinomas expressed ERB1 in three out of six cases and ERB2 in five out of six cases. The intensity of tumour nuclear ERB1 staining significantly correlated inversely with tumour weight (P=0.011), and patients whose tumours were classified as ERB1-negative had significantly greater tumour weight as well as higher serum calcium (P=0.002) and parathyroid hormone levels (P=0.003). Additionally, tumour nuclear ERB1 was not expressed differentially with respect to sex or age of the patient. Levels of tumour nuclear ERB2 did not correlate with clinical characteristics. In conclusion, decreased ERB1 immunoreactivity is associated with increased tumour weight in parathyroid adenomas. Given the previously reported correlation with tumour-suppressive signalling, selective oestrogen receptor modulation (SERMs) may play a role in the treatment of parathyroid carcinomas. Future studies of SERMs and oestrogen treatment in PHPT should consider tumour weight as a potential factor in pharmacological responsiveness. © 2015 The authors.

  13. TGF-beta receptor 2 downregulation in tumour-associated stroma worsens prognosis and high-grade tumours show more tumour-associated macrophages and lower TGF-beta1 expression in colon carcinoma: a retrospective study

    International Nuclear Information System (INIS)

    Bacman, David; Merkel, Susanne; Croner, Roland; Papadopoulos, Thomas; Brueckl, Wolfgang; Dimmler, Arno

    2007-01-01

    Histological phenotype and clinical behaviour of malignant tumours are not only dependent on alterations in the epithelial cell compartment, but are affected by their interaction with inflammatory cells and tumour-associated stroma. Studies in animal models have shown influence of tumour-associated macrophages (TAM) on histological grade of differentiation in colon carcinoma. Disruption of transforming growth factor beta (TGF-beta) signalling in tumour cells is related to more aggressive clinical behaviour. Expression data of components of this pathway in tumour-associated stroma is limited. Tissue micro arrays of 310 colon carcinomas from curatively resected patients in UICC stage II and III were established. In a first step we quantified amount of CD68 positive TAMs and expression of components of TGF-beta signalling (TGF-beta1, TGF-beta receptors type 1 and 2, Smad 3 and 4) in tumour and associated stroma. Further we analyzed correlation to histological and clinical parameters (histological grade of differentiation (low-grade (i.e. grade 1 and 2) vs. high-grade (i.e. grade 3 and 4)), lymph node metastasis, distant metastasis, 5 year cancer related survival) using Chi-square or Fisher's exact test, when appropriate, to compare frequencies, Kaplan-Meier method to calculate 5-year rates of distant metastases and cancer-related survival and log rank test to compare the rates of distant metastases and survival. To identify independent prognostic factors Cox regression analysis including lymph node status and grading was performed. High-grade tumours and those with lymph node metastases showed higher rates of TAMs and lower expression of TGF-beta1. Loss of nuclear Smad4 expression in tumor was associated with presence of lymph node metastasis, but no influence on prognosis could be demonstrated. Decrease of both TGF-beta receptors in tumour-associated stroma was associated with increased lymph node metastasis and shorter survival. Stromal TGF-beta receptor 2

  14. Can breast cancer patients with HER2 dual-equivocal tumours be managed as HER2-negative disease?

    Science.gov (United States)

    Tong, Yiwei; Chen, Xiaosong; Fei, Xiaochun; Lin, Lin; Wu, Jiayi; Huang, Ou; He, Jianrong; Zhu, Li; Chen, Weiguo; Li, Yafen; Shen, Kunwei

    2018-01-01

    Increasing human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC)/fluorescence in situ hybridisation (FISH) dual-equivocal breast tumours are reported after the 2013 American Society of Clinical Oncology/College of American Pathologists (ASCO/CAP) guideline update. The aim of this study is to investigate the clinico-pathologic characteristics, treatment patterns and disease outcome of these patients with HER2 dual-equivocal tumours. Patients with HER2 IHC 2+ and available FISH results were retrospectively analysed from the Comprehensive Breast Health Center, Shanghai Ruijin Hospital. The 2013 ASCO/CAP guideline was applied to define HER2-positive, dual-equivocal and -negative groups. Patient characteristics, systemic treatment patterns and survival were compared among these groups. Reverse transcriptase-polymerase chain reaction-based assays were applied to test HER2 mRNA expression level. Among 691 patients included, 133 (19.25%) were HER2 positive, 25 (3.62%) were HER2 dual-equivocal and 533 (77.13%) were HER2 negative. Univariate and multivariate analyses stated that HER2 dual-equivocal tumours shared more similarity with HER2-negative tumours, whereas HER2-positive tumours had rather different clinico-pathologic features. HER2 dual-equivocal tumours had similar HER2 mRNA levels compared with HER2-negative tumours (P = 0.26), which were much less compared with HER2-positive breast cancer. Besides, adjuvant systemic treatment patterns were comparable between HER2-negative and dual-equivocal tumours, and none of HER2 dual-equivocal patients received anti-HER2 treatment. There was no survival difference among these three groups (P = 0.43). HER2 dual-equivocal tumours share more similarity with HER2-negative disease in terms of clinico-pathologic features, HER2 mRNA levels, adjuvant systemic treatment patterns and disease outcome, which deserves further clinical evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. MR molecular imaging of tumours using ferritin heavy chain reporter gene expression mediated by the hTERT promoter

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yan [Third Military Medical University, Department of Radiology, XinQiao Hospital, ChongQing (China); The First Affiliated Hospital of ChengDu Medical College, Department of Radiology, ChengDu (China); Gong, Ming-fu; Yang, Hua; Zhang, Song; Wang, Guang-xian; Su, Tong-sheng; Wen, Li; Zhang, Dong [Third Military Medical University, Department of Radiology, XinQiao Hospital, ChongQing (China)

    2016-11-15

    Using the human telomerase reverse transcriptase (hTERT) promoter and the modified ferritin heavy chain (Fth) reporter gene, reporter gene expression for MRI was examined in telomerase positive and negative tumour cells and xenografts. Activity of the reporter gene expression vector Lenti-hTERT-Fth1-3FLAG-Puro was compared to constitutive CMV-driven expression and to the untransfected parental control in five tumour cell lines: A549, SKOV3, 293T, U2OS and HPDLF. In vitro, transfected cells were evaluated for FLAG-tagged protein expression, iron accumulation and transverse relaxation. In vivo, tumours transduced by lentiviral vector injection were imaged using T2*WI. Changes in tumour signal intensity were validated by histology. Only telomerase positive tumour cells expressed FLAG-tagged Fth and displayed an increase in R2* above the parental control, with a corresponding change in T2*WI. In addition, only telomerase positive tumours, transduced by injection of the reporter gene expression construct, exhibited a change in signal intensity on T2*WI. Tumour histology verified the expression of FLAG-tagged Fth and iron accumulation in telomerase positive tissue. Reporter gene expression for MRI, using the Fth reporter and the hTERT promoter, may be a useful strategy for the non-invasive diagnosis of many types of cancer. (orig.)

  16. Thymidilate synthase and p53 primary tumour expression as predictive factors for advanced colorectal cancer patients.

    Science.gov (United States)

    Paradiso, A; Simone, G; Petroni, S; Leone, B; Vallejo, C; Lacava, J; Romero, A; Machiavelli, M; De Lena, M; Allegra, C J; Johnston, P G

    2000-02-01

    The purpose of this work was to analyse the ability of p53 and thymidilate synthase (TS) primary tumour expression to retrospectively predict clinical response to chemotherapy and long-term prognosis in patients with advanced colorectal cancers homogeneously treated by methotrexate (MTX)-modulated-5-fluorouracil (5-FU-FA). A total of 108 advanced colorectal cancer patients entered the present retrospective study. Immunohistochemical p53 (pAb 1801 mAb) and TS (TS106 mAb) expression on formalin-fixed paraffin-embedded primary tumour specimens was related to probability of clinical response to chemotherapy, time to progression and overall survival. p53 was expressed in 53/108 (49%) tumours, while 54/108 (50%) showed TS immunostaining. No relationship was demonstrated between p53 positivity and clinical response to chemotherapy (objective response (OR): 20% vs 23%, in p53+ and p53- cases respectively) or overall survival. Percent of OR was significantly higher in TS-negative with respect to TS-positive tumours (30% vs 15% respectively; P < 0.04); simultaneous analysis of TS and p53 indicated 7% OR for p53-positive/TS-positive tumours vs 46% for p53-positive/TS-negative tumours (P < 0.03). Logistic regression analysis confirmed a significant association between TS tumour status and clinical response to chemotherapy (hazard ratio (HR): 2.91; 95% confidence interval (CI) 8.34-1.01; two-sided P < 0.05). A multivariate analysis of overall survival showed that only a small number of metastatic sites was statistically relevant (HR 1.89; 95% CI 2.85-1.26; two-sided P < 0.03). Our study suggests that immunohistochemical expression of p53 and TS could assist the clinician in predicting response of colorectal cancer patients to modulated MTX-5-FU therapy.

  17. Patient positioning in radiotherapy based on surface imaging using time of flight cameras

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, M., E-mail: marlene.gilles@univ-brest.fr; Fayad, H.; Clement, J. F.; Bert, J.; Visvikis, D. [INSERM, UMR 1101, LaTIM, Brest 29609 (France); Miglierini, P. [Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France); Scheib, S. [Varian Medical Systems Imaging Laboratory GmbH, Baden-Daettwil 5405 (Switzerland); Cozzi, L. [Radiotherapy and Radiosurgery Department, Instituto Clinico Humanitas, Rozzano 20089 (Italy); Boussion, N.; Schick, U.; Pradier, O. [INSERM, UMR 1101, LaTIM, Brest 29609, France and Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France)

    2016-08-15

    Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

  18. Imaging of sacral tumours

    International Nuclear Information System (INIS)

    Gerber, S.; Ollivier, L.; Brisse, H.; Neuenschwander, S.; Leclere, J.; Vanel, D.; Missenard, G.; Pinieux, G. de

    2008-01-01

    All components of the sacrum (bone, cartilage, bone marrow, meninges, nerves, notochord remnants, etc.) can give rise to benign or malignant tumours. Bone metastases and intraosseous sites of haematological malignancies, lymphoma and multiple myeloma are the most frequent aetiologies, while primary bone tumours and meningeal or nerve tumours are less common. Some histological types have a predilection for the sacrum, especially chordoma and giant cell tumour. Clinical signs are usually minor, and sacral tumours are often discovered in the context of nerve root or pelvic organ compression. The roles of conventional radiology, CT and MRI are described and compared with the histological features of the main tumours. The impact of imaging on treatment decisions and follow-up is also reviewed. (orig.)

  19. Imaging of sacral tumours

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, S.; Ollivier, L.; Brisse, H.; Neuenschwander, S. [Institut Curie, Department of Radiology, Paris (France); Leclere, J. [Institut Gustave Roussy, Department of Radiology, Villejuif (France); Vanel, D. [The Rizzoli Institute, Department of Radiology, Bologna (Italy); Missenard, G. [Institut Gustave Roussy, Comite de pathologie tumorale de l' appareil locomoteur, Villejuif (France); Pinieux, G. de [CHRU de Tours, Department of Pathology, Hopital Trousseau, Tours (France)

    2008-04-15

    All components of the sacrum (bone, cartilage, bone marrow, meninges, nerves, notochord remnants, etc.) can give rise to benign or malignant tumours. Bone metastases and intraosseous sites of haematological malignancies, lymphoma and multiple myeloma are the most frequent aetiologies, while primary bone tumours and meningeal or nerve tumours are less common. Some histological types have a predilection for the sacrum, especially chordoma and giant cell tumour. Clinical signs are usually minor, and sacral tumours are often discovered in the context of nerve root or pelvic organ compression. The roles of conventional radiology, CT and MRI are described and compared with the histological features of the main tumours. The impact of imaging on treatment decisions and follow-up is also reviewed. (orig.)

  20. Localisation of malignant germ-cell tumours by external scanning after injection of radiolabelled anti-alpha-fetoprotein

    International Nuclear Information System (INIS)

    Halsall, A.K.; Fairweather, D.S.; Bradwell, A.R.; Blackburn, J.C.; Howell, A.; Dykes, P.W.; Reeder, A.; Hine, K.R.

    1981-01-01

    Sheep IgG antibody to alpha-fetoprotein was labelled with 131 I and used to identify human germ-cell tumours by emission scanning. Eleven patients were studied after resection of their primary tumours. Ten had malignant teratoma and one an endodermal sinus tumour. All eight patients with raised serum alpha-fetoprotein concentrations had metastases apparent in the antibody scans. Of the remaining three patients with normal serum alpha-fetoprotein concentrations, two had positive scans. Three of the patients with positive results were scanned twice; the second scans were negative after treatment, when the alpha-fetoprotein concentrations had returned to normal. These results suggest that antibody scans are useful in the clinical management of patients with germ-cell tumours. (author)

  1. Antitumour effects of combined radio- and parvovirotherapy in N-Ras-positive tumour cells

    International Nuclear Information System (INIS)

    Angelova, A.; Galabov, A.; Rommelaere, J.; Raykov, Z.

    2007-01-01

    Many innovative approaches have attempted to challenge the dominant position of surgery, chemotherapy and radiotherapy as the major therapeutic modalities to treat cancer. However, only recently some new agents have appeared that achieve effects comparable to the ones of these established treatments. A novel class of such therapeutics consists of oncolytic viruses with several main representatives, namely adeno-, herpes, reo- and parvovirus. The latter class of anticancer agents has proven to be quite effective in many preclinical models and is now considered for a phase I clinical trial in patients with glioma and pancreatic cancer. An important question to be answered is whether virotherapy can be combined with standard treatments to achieve an enhanced antitumor effect still at a low level of toxicity. Here we present data concerning the application of irradiation together with H-1PV parvovirus infection comparing their toxic effects on normal and Ras -transformed fibroblasts. This proved to be a potent combination achieving high level of synergistic toxicity on transformed cells at doses, which did not affect the viability of normal human fibroblasts. This strategy holds promise to become a part of the clinical treatment of radioresistant tumours. (authors)

  2. Automatic online and real-time tumour motion monitoring during stereotactic liver treatments on a conventional linac by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK)

    Science.gov (United States)

    Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.

    2018-03-01

    The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion

  3. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment

    International Nuclear Information System (INIS)

    Kuenzler, Thomas; Grezdo, Jozef; Bogner, Joachim; Birkfellner, Wolfgang; Georg, Dietmar

    2007-01-01

    Image guidance has become a pre-requisite for hypofractionated radiotherapy where the applied dose per fraction is increased. Particularly in stereotactic body radiotherapy (SBRT) for lung tumours, one has to account for set-up errors and intrafraction tumour motion. In our feasibility study, we compared digitally reconstructed radiographs (DRRs) of lung lesions with MV portal images (PIs) to obtain the displacement of the tumour before irradiation. The verification of the tumour position was performed by rigid intensity based registration and three different merit functions such as the sum of squared pixel intensity differences, normalized cross correlation and normalized mutual information. The registration process then provided a translation vector that defines the displacement of the target in order to align the tumour with the isocentre. To evaluate the registration algorithms, 163 test images were created and subsequently, a lung phantom containing an 8 cm 3 tumour was built. In a further step, the registration process was applied on patient data, containing 38 tumours in 113 fractions. To potentially improve registration outcome, two filter types (histogram equalization and display equalization) were applied and their impact on the registration process was evaluated. Generated test images showed an increase in successful registrations when applying a histogram equalization filter whereas the lung phantom study proved the accuracy of the selected algorithms, i.e. deviations of the calculated translation vector for all test algorithms were below 1 mm. For clinical patient data, successful registrations occurred in about 59% of anterior-posterior (AP) and 46% of lateral projections, respectively. When patients with a clinical target volume smaller than 10 cm 3 were excluded, successful registrations go up to 90% in AP and 50% in lateral projection. In addition, a reliable identification of the tumour position was found to be difficult for clinical target

  4. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kuenzler, Thomas [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria); Grezdo, Jozef [Department of Radiotherapy, St Elisabeth Institute of Oncology, Bratislava (Slovakia); Bogner, Joachim [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria); Birkfellner, Wolfgang [Center for Biomedical Engineering and Physics, Medical University Vienna, Vienna (Austria); Georg, Dietmar [Department of Radiotherapy and Radiobiology, Medical University Vienna, Vienna (Austria)

    2007-04-21

    Image guidance has become a pre-requisite for hypofractionated radiotherapy where the applied dose per fraction is increased. Particularly in stereotactic body radiotherapy (SBRT) for lung tumours, one has to account for set-up errors and intrafraction tumour motion. In our feasibility study, we compared digitally reconstructed radiographs (DRRs) of lung lesions with MV portal images (PIs) to obtain the displacement of the tumour before irradiation. The verification of the tumour position was performed by rigid intensity based registration and three different merit functions such as the sum of squared pixel intensity differences, normalized cross correlation and normalized mutual information. The registration process then provided a translation vector that defines the displacement of the target in order to align the tumour with the isocentre. To evaluate the registration algorithms, 163 test images were created and subsequently, a lung phantom containing an 8 cm{sup 3} tumour was built. In a further step, the registration process was applied on patient data, containing 38 tumours in 113 fractions. To potentially improve registration outcome, two filter types (histogram equalization and display equalization) were applied and their impact on the registration process was evaluated. Generated test images showed an increase in successful registrations when applying a histogram equalization filter whereas the lung phantom study proved the accuracy of the selected algorithms, i.e. deviations of the calculated translation vector for all test algorithms were below 1 mm. For clinical patient data, successful registrations occurred in about 59% of anterior-posterior (AP) and 46% of lateral projections, respectively. When patients with a clinical target volume smaller than 10 cm{sup 3} were excluded, successful registrations go up to 90% in AP and 50% in lateral projection. In addition, a reliable identification of the tumour position was found to be difficult for clinical

  5. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours; first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives.

    Science.gov (United States)

    Decristoforo, C; Mather, S J; Cholewinski, W; Donnemiller, E; Riccabona, G; Moncayo, R

    2000-09-01

    [111In-diethylene triamine penta-acetic acid-D-Phe1]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99mTc-EDDA/HYNIC-TOC were compared with those of 111In-DTPA-octreotide in six cases, and with those of 111In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111In-DTPA-octreotide but faster than that of 111In-DOTA-TOC, while urinary excretion was lower compared with the 111In derivatives. Semi-quantitative region of interest analysis showed that 99mTc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99mTc images. We conclude that 99mTcEDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111In-labelled octreotide derivatives.

  6. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours: first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives

    International Nuclear Information System (INIS)

    Decristoforo, C.; Cholewinski, W.; Donnemiller, E.; Riccabona, G.; Moncayo, R.

    2000-01-01

    [ 111 In-diethylene triamine penta-acetic acid-d-Phe 1 ]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99m Tc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99m Tc-EDDA/HYNIC-TOC were compared with those of 111 In-DTPA-octreotide in six cases, and with those of 111 In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111 In-DTPA-octreotide but faster than that of 111 In-DOTA-TOC, while urinary excretion was lower compared with the 111 In derivatives. Semi-quantitative region of interest analysis showed that 99m Tc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111 In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99m Tc images. We conclude that 99m Tc-EDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111 In-labelled octreotide derivatives. (orig.)

  7. Radiolabelled peptides for tumour therapy: current status and future directions. Plenary lecture at the EANM 2002

    International Nuclear Information System (INIS)

    Jong, Marion de; Kwekkeboom, Dik; Valkema, Roelf; Krenning, Eric P.

    2003-01-01

    On their plasma membranes, cells express receptor proteins with high affinity for regulatory peptides, such as somatostatin. Changes in the density of these receptors during disease, e.g. overexpression in many tumours, provide the basis for new imaging methods. The first peptide analogues successfully applied for visualisation of receptor-positive tumours were radiolabelled somatostatin analogues. The next step was to label these analogues with therapeutic radionuclides for peptide receptor radionuclide therapy (PRRT). Results from preclinical and clinical multicentre studies have already shown an effective therapeutic response when using radiolabelled somatostatin analogues to treat receptor-positive tumours. Infusion of positively charged amino acids reduces kidney uptake, enlarging the therapeutic window. For PRRT of CCK-B receptor-positive tumours, such as medullary thyroid carcinoma, radiolabelled minigastrin analogues are currently being successfully applied. The combination of different therapy modalities holds interest as a means of improving the clinical therapeutic effects of radiolabelled peptides. The combination of different radionuclides, such as 177 Lu- and 90 Y-labelled somatostatin analogues, to reach a wider tumour region of high curability, has been described. A variety of other peptide-based radioligands, such as bombesin and NPY(Y 1 ) analogues, receptors for which are expressed on common cancers such as prostate and breast cancer, are currently under development and in different phases of (pre)clinical investigation. Multi-receptor tumour targeting using the combination of bombesin and NPY(Y 1 ) analogues is promising for scintigraphy and PRRT of breast carcinomas and their lymph node metastases. (orig.)

  8. Quality assurance device for four-dimensional IMRT or SBRT and respiratory gating using patient-specific intrafraction motion kernels.

    Science.gov (United States)

    Nelms, Benjamin E; Ehler, Eric; Bragg, Henry; Tomé, Wolfgang A

    2007-09-17

    Emerging technologies such as four-dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity-modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must consider the interplay between the temporal nature of the modulation and the target motion within the ITV. A need exists for a 4D IMRT/SBRT quality assurance (QA) device that can incorporate and analyze customized intrafraction motion as it relates to dose delivery and respiratory gating. We built a 4D IMRT/SBRT prototype device and entered (X, Y, Z)(T) coordinates representing a motion kernel into a software application that 1. transformed the kernel into beam-specific two-dimensional (2D) motion "projections," 2. previewed the motion in real time, and 3. drove a recision X-Y motorized device that had, atop it, a mounted planar IMRT QA measurement device. The detectors that intersected the target in the beam's-eye-view of any single phase of the breathing cycle (a small subset of all the detectors) were defined as "target detectors" to be analyzed for dose uniformity between multiple fractions. Data regarding the use of this device to quantify dose variation fraction-to-fraction resulting from target motion (for several delivery modalities and with and without gating) have been recently published. A combined software and hardware solution for patient-customized 4D IMRT/SBRT QA is an effective tool for assessing IMRT delivery under conditions of intrafraction motion. The 4D IMRT QA device accurately reproduced the projected motion kernels for all beam's-eye-view motion kernels. This device has been proved to, effectively quantify the degradation in dose uniformity resulting from a moving target within a static planning target volume, and, integrate with a commercial

  9. Quality assurance device for four‐dimensional IMRT or SBRT and respiratory gating using patient‐specific intrafraction motion kernels

    Science.gov (United States)

    Ehler, Eric; Bragg, Henry; Tomé, Wolfgang A.

    2007-01-01

    Emerging technologies such as four‐dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity‐modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must consider the interplay between the temporal nature of the modulation and the target motion within the ITV. A need exists for a 4D IMRT/SBRT quality assurance (QA) device that can incorporate and analyze customized intrafraction motion as it relates to dose delivery and respiratory gating. We built a 4D IMRT/SBRT prototype device and entered (X, Y, Z)(T) coordinates representing a motion kernel into a software application that transformed the kernel into beam‐specific two‐dimensional (2D) motion “projections,”previewed the motion in real time, anddrove a precision X–Y motorized device that had, atop it, a mounted planar IMRT QA measurement device. The detectors that intersected the target in the beam's‐eye‐view of any single phase of the breathing cycle (a small subset of all the detectors) were defined as “target detectors” to be analyzed for dose uniformity between multiple fractions. Data regarding the use of this device to quantify dose variation fraction‐to‐fraction resulting from target motion (for several delivery modalities and with and without gating) have been recently published. A combined software and hardware solution for patient‐customized 4D IMRT/ SBRT QA is an effective tool for assessing IMRT delivery under conditions of intrafraction motion. The 4D IMRT QA device accurately reproduced the projected motion kernels for all beam's‐eye‐view motion kernels. This device has been proved to • effectively quantify the degradation in dose uniformity resulting from a moving target within a static planning target volume, and • integrate

  10. The Askin tumour. Neuroactodermic tumour of the thoracic wall

    International Nuclear Information System (INIS)

    Velazquez, P.; Nicolas, A. I.; Vivas, I.; Damaso Aquerreta, J.; Martinez-Cuesta, A.

    1999-01-01

    The Askin tumours is an extremely rare and malignant process in the thoracic pulmonary region during infancy and youth. The differential diagnosis has to be considered with other thoracic wall tumours that are more common in pediatrics like the undifferentiated neuroblastoma, the embionic rabdomiosarcoma, the Ewing sarcoma and the linfoma. A retrospective examination was carried out on 473 thoracic wall tumours from 1994 to 1997 at our centre, resulting in 4 patients with an anatomopathologically tested Askin tumour (ages from 13-21). All the cases were studied using simple radiography and CT. In two cases MRI was also used. The most common clinical manifestation was a palpable painful mass in the thoracic wall. In the simple radiograph the main finding was a large mass of extrapleural soft material, with costal destruction ( n=3) and a pleural effusion (n=2). In the CT study the mass was heterogeneous, with internal calcifications in one case. CT and MRI showed invasion in the mediastinum (n=1), medular channel (n=1) and phrenic and sulphrenic extension (n=1). The Askin tumour should be included in the differential diagnosis of thoracic wall masses in infant-youth ages. There are no specific morphological characteristics. Both CT and MRI are useful for the diagnosis, staging and follow up. (Author) 11 refs

  11. Contribution of radioisotopes in the diagnosis of lung tumours

    International Nuclear Information System (INIS)

    Raynaud, C.; Crouzel, M.

    1976-01-01

    197 Hg, a radioisotope of half life 65 h, injected as acetate builds up in malignant tumours and evolutive inflammatory lesions. In spite of a high proportion of false positives it can lead to a lung cancer diagnosis under well-defined circumstances such as: round lung images, X-ray tuberculosis images persisting after prolonged therapy, treated cancers where it can detect relapses before X-rays and in the difficult case of benign tumours. In man the uptake kinetics of carrier-free 67 Cu (half-life 58 h), injected as citrate, are apparently not the same in cancers as in evolutive inflammatory lesions. The false positive yield, through much lower than that observed with 197 Hg, is still too high in this preliminary study [fr

  12. Contribution of radioisotopes in the diagnosis of lung tumours

    Energy Technology Data Exchange (ETDEWEB)

    Raynaud, C; Crouzel, M [CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot

    1976-12-01

    Mercury-197, a radioisotope of half life 65 h, injected as acetate builds up in malignant tumours and evolutive inflammatory lesions. In spite of a high proportion of false positives it can lead to a lung cancer diagnosis under well-defined circumstances such as: round lung images, x-ray tuberculosis images persisting after prolonged therapy, treated cancers where it can detect relapses before X-rays and in the difficult case of benign tumours. In man the uptake kinetics of carrier-free /sup 67/Cu (half-life 58 h), injected as citrate, are apparently not the same in cancers as in evolutive inflammatory lesions. The false positive yield, through much lower than that observed with /sup 197/Hg, is still too high in this preliminary study.

  13. TGF-beta receptor 2 downregulation in tumour-associated stroma worsens prognosis and high-grade tumours show more tumour-associated macrophages and lower TGF-beta1 expression in colon carcinoma: a retrospective study

    Directory of Open Access Journals (Sweden)

    Papadopoulos Thomas

    2007-08-01

    Full Text Available Abstract Background Histological phenotype and clinical behaviour of malignant tumours are not only dependent on alterations in the epithelial cell compartment, but are affected by their interaction with inflammatory cells and tumour-associated stroma. Studies in animal models have shown influence of tumour-associated macrophages (TAM on histological grade of differentiation in colon carcinoma. Disruption of transforming growth factor beta (TGF-beta signalling in tumour cells is related to more aggressive clinical behaviour. Expression data of components of this pathway in tumour-associated stroma is limited. Methods Tissue micro arrays of 310 colon carcinomas from curatively resected patients in UICC stage II and III were established. In a first step we quantified amount of CD68 positive TAMs and expression of components of TGF-beta signalling (TGF-beta1, TGF-beta receptors type 1 and 2, Smad 3 and 4 in tumour and associated stroma. Further we analyzed correlation to histological and clinical parameters (histological grade of differentiation (low-grade (i.e. grade 1 and 2 vs. high-grade (i.e. grade 3 and 4, lymph node metastasis, distant metastasis, 5 year cancer related survival using Chi-square or Fisher's exact test, when appropriate, to compare frequencies, Kaplan-Meier method to calculate 5-year rates of distant metastases and cancer-related survival and log rank test to compare the rates of distant metastases and survival. To identify independent prognostic factors Cox regression analysis including lymph node status and grading was performed. Results High-grade tumours and those with lymph node metastases showed higher rates of TAMs and lower expression of TGF-beta1. Loss of nuclear Smad4 expression in tumor was associated with presence of lymph node metastasis, but no influence on prognosis could be demonstrated. Decrease of both TGF-beta receptors in tumour-associated stroma was associated with increased lymph node metastasis and

  14. lmmunohistochemical study of effect of ionizing radiation on human malignant tumours

    International Nuclear Information System (INIS)

    Adomaitiene, D. I.; Aleknavicius, E.; Valuckas, K. and others

    2000-01-01

    Cell proliferation-associated tumour markers are considered to have a valuable clinical significance. The current study was designed to investigate changes in immunohistochemical (IH) expression of proliferating cell nuclear antigen PCNA in human malignant tumour tissue samples obtained before and after preoperative radiotherapy. Tumour tissue samples were obtained from 26 patients with rectal carcinoma, from 22 patients with carcinoma corporis uteri and from 82 patients with breast cancer. Tumour samples were processed for IH examination by using monoclonal antibodies (MoAbs) PC10 against PCNA. IH analysis of histological specimens of carcinoma corporis uteri and rectal carcinoma obtained before and after preoperative radiotherapy has revealed heterogeneity of biological response to irradiation. The great majority of tumour specimens after irradiation showed a high PCNA expression level in cell population. Only minority of tumour specimens (15-20%) exhibited reduced immunoreactivity with MoAbs PC10. PCNA positivity rate in breast cancer specimens obtained during surgery from 55 patients after preoperative radiotherapy in comparison to biomarker expression pattern in tumour specimens from 27 unirradiated patients (control group) was found to be tended to decrease. These in vivo findings are discussed in terms of radiation-induced cell death, followed after proliferation, and PCNA role in DNA repair. (author)

  15. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  16. The relationship between tumour size, nodal status and distant metastases: on the origins of breast cancer.

    Science.gov (United States)

    Sopik, Victoria; Narod, Steven A

    2018-04-24

    In patients with breast cancer, increasing tumour size at diagnosis is associated with an increased likelihood of axillary lymph node involvement and increased breast cancer-specific mortality. However, this relation is based on studies which combine all tumours smaller than 1.0 cm in a single category and all tumours larger than 5.0 cm in another category. This coarse classification may obscure a nuanced description of the effects of tumour size across the full range of possible sizes. We examined the relationship between primary tumour size, lymph node status and distant metastases in a cohort of 819,647 women diagnosed with first primary invasive breast cancer from 1990 to 2014 in the Surveillance, Epidemiology and End Results (SEER) registries database. All patients in the cohort had a known primary tumour size between 1 and 150 mm in greatest dimension. Primary tumour size was examined as a continuous (1-150 mm) and categorical variable (15 size groups; 10-mm intervals). For each 1- or 10-mm size group, we determined the proportion of patients with positive lymph nodes at diagnosis, the proportion of patients with distant metastases at diagnosis and the actuarial cumulative risk of breast cancer-specific mortality at 15 years from diagnosis. Among 819,647 patients with invasive breast tumours between 1 and 150 mm in size, there was a non-linear correlation between increasing tumour size and the prevalence of lymph node metastases at diagnosis (% node-positive), the prevalence of distant metastases at diagnosis (% stage IV) and the 15-year rate of breast cancer-specific mortality across the entire size spectrum. For very small tumours (under 10 mm) and for very large tumours (larger than 60-90 mm) there was little correlation between tumour size and metastasis risk. The relationship between tumour size, lymph node status and distant metastases in patients with invasive breast cancer is not linear. This calls into question the conventional model that the

  17. Three-Dimensional Intrafractional Motion of Breast During Tangential Breast Irradiation Monitored With High-Sampling Frequency Using a Real-Time Tumor-Tracking Radiotherapy System

    International Nuclear Information System (INIS)

    Kinoshita, Rumiko; Shimizu, Shinichi; Taguchi, Hiroshi; Katoh, Norio; Fujino, Masaharu; Onimaru, Rikiya; Aoyama, Hidefumi; Katoh, Fumi; Omatsu, Tokuhiko; Ishikawa, Masayori; Shirato, Hiroki

    2008-01-01

    Purpose: To evaluate the three-dimensional intrafraction motion of the breast during tangential breast irradiation using a real-time tracking radiotherapy (RT) system with a high-sampling frequency. Methods and Materials: A total of 17 patients with breast cancer who had received breast conservation RT were included in this study. A 2.0-mm gold marker was placed on the skin near the nipple of the breast for RT. A fluoroscopic real-time tumor-tracking RT system was used to monitor the marker. The range of motion of each patient was calculated in three directions. Results: The mean ± standard deviation of the range of respiratory motion was 1.0 ± 0.6 mm (median, 0.9; 95% confidence interval [CI] of the marker position, 0.4-2.6), 1.3 ± 0.5 mm (median, 1.1; 95% CI, 0.5-2.5), and 2.6 ± 1.4 (median, 2.3; 95% CI, 1.0-6.9) for the right-left, craniocaudal, and anteroposterior direction, respectively. No correlation was found between the range of motion and the body mass index or respiratory function. The mean ± standard deviation of the absolute value of the baseline shift in the right-left, craniocaudal, and anteroposterior direction was 0.2 ± 0.2 mm (range, 0.0-0.8 mm), 0.3 ± 0.2 mm (range, 0.0-0.7 mm), and 0.8 ± 0.7 mm (range, 0.1-1.8 mm), respectively. Conclusion: Both the range of motion and the baseline shift were within a few millimeters in each direction. As long as the conventional wedge-pair technique and the proper immobilization are used, the intrafraction three-dimensional change in the breast surface did not much influence the dose distribution

  18. Radiation-induced brain tumours: potential late complications of radiation therapy for brain tumours

    International Nuclear Information System (INIS)

    Nishio, S.; Morioka, T.; Inamura, T.; Takeshita, I.; Fukui, M.; Sasaki, M.; Nakamura, K.; Wakisaka, S.

    1998-01-01

    The development of neoplasms subsequent to therapeutic cranial irradiation is a rare but serious and potentially fatal complication. In this study, we retrospectively reviewed the clinical and pathological aspects of 11 patients who underwent cranial irradiation (range, 24-110 cGy) to treat their primary disease and thereafter developed secondary tumours within a span of 13 years. All tumours arose within the previous radiation fields, and satisfied the widely used criteria for the definition of radiation-induced neoplasms. There was no sex predominance (M: 5, F: 6) and the patients tended to be young at irradiation (1.3 - 42 years; median age: 22 years). The median latency period before the detection of the secondary tumour was 14.5 years (range: 6.5 - 24 years). Meningiomas developed in 5 patients, sarcomas in 4, and malignant gliomas in 2. A pre-operative diagnosis of a secondary tumour was correctly obtained in 10 patients based on the neuro-imaging as well as nuclear medicine findings. All patients underwent a surgical removal of the secondary tumour, 3 underwent additional chemotherapy, and one received stereotactic secondary irradiation therapy. During a median of 2 years of follow-up review after the diagnosis of a secondary tumour, 3 patients died related to the secondary tumours (2 sarcomas, 1 glioblastoma), one died of a recurrent primary glioma, while the remaining 7 have been alive for from 10 months to 12 years after being treated for the secondary tumours (median: 3 years). Based on these data, the clinicopathological characteristics and possible role of treatment for secondary tumours are briefly discussed. (author)

  19. FOXP3 positive regulatory T-cells in cutaneous and systemic CD30 positive T-cell lymphoproliferations

    DEFF Research Database (Denmark)

    Gjerdrum, Lise Mette; Woetmann, Anders; Ødum, Niels

    2008-01-01

    for FOXP3 expression in tumour cells and tumour infiltrating Tregs. Labelling of a majority of the neoplastic cells was seen in one case of C-ALCL. Another three cases (one LyP and two C-ALCL) displayed weak labelling of very occasional atypical T-cells. In the remaining 38 cases the atypical lymphoid...... infiltrate was FOXP3 negative. By contrast, all biopsies contained tumour infiltrating FOXP3-positive Tregs. Significant higher numbers were recorded in ALK negative S-ALCL and LyP than in C-ALCL and S-ALCL positive for ALK. In conclusion, it is shown that FOXP3 expression in cutaneous and systemic CD30...

  20. Experimental tumour treatment

    International Nuclear Information System (INIS)

    1985-08-01

    This report of 1984 is the seventh in a series and presents that year's results of continuous studies in the domain of experimental tumour radiotherapy. In the year under review, more personnel has been available for the studies, and the scientific programmes for the assessment of acute and chronic side effects of radiotherapies have been extended. New models have been developed, among them a first system based on animal experiments, for quantifying the mucositis of the oral and pharyngeal mucosa, a limiting condition in the radiotherapy of head and throat tumours. Another significant advancement is a model for quantification of chronical damage to the ureter, which still is a serious problem in the radiotherapy of gynaecological tumours. The 1984 experimental tumour studies have been mainly devoted to the repopulation and split-dose recovery in various tumours, concentrating on dose fractionation as one of the major problems studies. Particular interest has been attached to the processes involved in treatments over several weeks with a daily effective dose of 2 Gy. (orig./MG) [de

  1. BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T

    International Nuclear Information System (INIS)

    Landuyt, W.; Bogaert, W. van den; Lambin, P.; Hermans, R.; Bosmans, H.; Sunaert, S.; Beatse, E.; Farina, D.; Meijerink, M.; Zhang, H.; Marchal, G.

    2001-01-01

    The aim of this study was to evaluate the feasibility of functional MR imaging (fMRI) at 1.5 T, exploiting blood oxygenation level-dependent (BOLD) contrast, for detecting changes in whole-tumour oxygenation induced by carbogen (5% CO 2 +95% O 2 ) inhalation of the host. Adult WAG/Rij rats with rhabdomyosarcomas growing subcutaneously in the lower flank were imaged when tumours reached sizes between 1 and 11 cm 3 (n=12). Air and carbogen were alternatively supplied at 2 l/min using a snout mask. Imaging was done on a 1.5-T MR scanner using a T2*-weighted gradient-echo, echo-planar imaging (GE-EPI) sequence. Analysis of the whole-tumour EPI images was based on statistical parametric maps. Voxels with and without signal intensity changes (SIC) were recorded. Significance thresholds were set at p<0.05, corrected for multiple comparisons. In continuous air breathing condition, 3 of 12 tumours showed significant negative SIC and 1 tumour had a clear-cut positive SIC. The remaining tumours showed very little or no change. When switching to carbogen breathing, the SIC were significantly positive in 10 of 12 tumours. Negative SIC were present in 4 tumours, of which three were simultaneously characterised by positive SIC. The overall analysis indicated that 6 of the 12 tumours could be considered as strong positive responders to carbogen. Our research demonstrates the applicability of fMRI GE-EPI at 1.5 T to study whole-tumour oxygenation non-invasively. The observed negative SIC during air condition may reflect the presence of transient hypoxia during these measurements. Selection of tumours on the basis of their individual response to carbogen is possible, indicating a role of such non-invasive measurements for using tailor-made treatments. (orig.)

  2. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Mazur, Thomas R.; Curcuru, Austen; Sona, Karl; Kashani, Rojano; Green, Olga; Ochoa, Laura; Mutic, Sasa; Zoberi, Imran; Li, H. Harold; Thomas, Maria A., E-mail: mthomas@radonc.wustl.edu

    2016-11-15

    Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

  3. SU-F-J-105: Towards a Novel Treatment Planning Pipeline Delivering Pareto- Optimal Plans While Enabling Inter- and Intrafraction Plan Adaptation

    Energy Technology Data Exchange (ETDEWEB)

    Kontaxis, C; Bol, G; Lagendijk, J; Raaymakers, B [University Medical Center Utrecht, Utrecht (Netherlands); Breedveld, S; Sharfo, A; Heijmen, B [Erasmus University Medical Center Rotterdam, Rotterdam (Netherlands)

    2016-06-15

    Purpose: To develop a new IMRT treatment planning methodology suitable for the new generation of MR-linear accelerator machines. The pipeline is able to deliver Pareto-optimal plans and can be utilized for conventional treatments as well as for inter- and intrafraction plan adaptation based on real-time MR-data. Methods: A Pareto-optimal plan is generated using the automated multicriterial optimization approach Erasmus-iCycle. The resulting dose distribution is used as input to the second part of the pipeline, an iterative process which generates deliverable segments that target the latest anatomical state and gradually converges to the prescribed dose. This process continues until a certain percentage of the dose has been delivered. Under a conventional treatment, a Segment Weight Optimization (SWO) is then performed to ensure convergence to the prescribed dose. In the case of inter- and intrafraction adaptation, post-processing steps like SWO cannot be employed due to the changing anatomy. This is instead addressed by transferring the missing/excess dose to the input of the subsequent fraction. In this work, the resulting plans were delivered on a Delta4 phantom as a final Quality Assurance test. Results: A conventional static SWO IMRT plan was generated for two prostate cases. The sequencer faithfully reproduced the input dose for all volumes of interest. For the two cases the mean relative dose difference of the PTV between the ideal input and sequenced dose was 0.1% and −0.02% respectively. Both plans were delivered on a Delta4 phantom and passed the clinical Quality Assurance procedures by achieving 100% pass rate at a 3%/3mm gamma analysis. Conclusion: We have developed a new sequencing methodology capable of online plan adaptation. In this work, we extended the pipeline to support Pareto-optimal input and clinically validated that it can accurately achieve these ideal distributions, while its flexible design enables inter- and intrafraction plan

  4. SU-F-J-105: Towards a Novel Treatment Planning Pipeline Delivering Pareto- Optimal Plans While Enabling Inter- and Intrafraction Plan Adaptation

    International Nuclear Information System (INIS)

    Kontaxis, C; Bol, G; Lagendijk, J; Raaymakers, B; Breedveld, S; Sharfo, A; Heijmen, B

    2016-01-01

    Purpose: To develop a new IMRT treatment planning methodology suitable for the new generation of MR-linear accelerator machines. The pipeline is able to deliver Pareto-optimal plans and can be utilized for conventional treatments as well as for inter- and intrafraction plan adaptation based on real-time MR-data. Methods: A Pareto-optimal plan is generated using the automated multicriterial optimization approach Erasmus-iCycle. The resulting dose distribution is used as input to the second part of the pipeline, an iterative process which generates deliverable segments that target the latest anatomical state and gradually converges to the prescribed dose. This process continues until a certain percentage of the dose has been delivered. Under a conventional treatment, a Segment Weight Optimization (SWO) is then performed to ensure convergence to the prescribed dose. In the case of inter- and intrafraction adaptation, post-processing steps like SWO cannot be employed due to the changing anatomy. This is instead addressed by transferring the missing/excess dose to the input of the subsequent fraction. In this work, the resulting plans were delivered on a Delta4 phantom as a final Quality Assurance test. Results: A conventional static SWO IMRT plan was generated for two prostate cases. The sequencer faithfully reproduced the input dose for all volumes of interest. For the two cases the mean relative dose difference of the PTV between the ideal input and sequenced dose was 0.1% and −0.02% respectively. Both plans were delivered on a Delta4 phantom and passed the clinical Quality Assurance procedures by achieving 100% pass rate at a 3%/3mm gamma analysis. Conclusion: We have developed a new sequencing methodology capable of online plan adaptation. In this work, we extended the pipeline to support Pareto-optimal input and clinically validated that it can accurately achieve these ideal distributions, while its flexible design enables inter- and intrafraction plan

  5. Postoperative weight gain after standard Whipple's procedure versus pylorus-preserving pancreatoduodenectomy: the influence of tumour status

    NARCIS (Netherlands)

    van Berge Henegouwen, M. I.; Moojen, T. M.; van Gulik, T. M.; Rauws, E. A.; Obertop, H.; Gouma, D. J.

    1998-01-01

    BACKGROUND: Recent reports suggest a better postoperative weight gain after pylorus-preserving pancreatoduodenectomy (PPPD) compared with standard pancreatoduodenectomy (PD). Factors that could also influence postoperative weight gain, such as tumour-positive resection margins and tumour recurrence,

  6. Adapting radiotherapy to hypoxic tumours

    International Nuclear Information System (INIS)

    Malinen, Eirik; Soevik, Aste; Hristov, Dimitre; Bruland, Oeyvind S; Olsen, Dag Rune

    2006-01-01

    In the current work, the concepts of biologically adapted radiotherapy of hypoxic tumours in a framework encompassing functional tumour imaging, tumour control predictions, inverse treatment planning and intensity modulated radiotherapy (IMRT) were presented. Dynamic contrast enhanced magnetic resonance imaging (DCEMRI) of a spontaneous sarcoma in the nasal region of a dog was employed. The tracer concentration in the tumour was assumed related to the oxygen tension and compared to Eppendorf histograph measurements. Based on the pO 2 -related images derived from the MR analysis, the tumour was divided into four compartments by a segmentation procedure. DICOM structure sets for IMRT planning could be derived thereof. In order to display the possible advantages of non-uniform tumour doses, dose redistribution among the four tumour compartments was introduced. The dose redistribution was constrained by keeping the average dose to the tumour equal to a conventional target dose. The compartmental doses yielding optimum tumour control probability (TCP) were used as input in an inverse planning system, where the planning basis was the pO 2 -related tumour images from the MR analysis. Uniform (conventional) and non-uniform IMRT plans were scored both physically and biologically. The consequences of random and systematic errors in the compartmental images were evaluated. The normalized frequency distributions of the tracer concentration and the pO 2 Eppendorf measurements were not significantly different. 28% of the tumour had, according to the MR analysis, pO 2 values of less than 5 mm Hg. The optimum TCP following a non-uniform dose prescription was about four times higher than that following a uniform dose prescription. The non-uniform IMRT dose distribution resulting from the inverse planning gave a three times higher TCP than that of the uniform distribution. The TCP and the dose-based plan quality depended on IMRT parameters defined in the inverse planning procedure

  7. Adapting radiotherapy to hypoxic tumours

    Science.gov (United States)

    Malinen, Eirik; Søvik, Åste; Hristov, Dimitre; Bruland, Øyvind S.; Rune Olsen, Dag

    2006-10-01

    In the current work, the concepts of biologically adapted radiotherapy of hypoxic tumours in a framework encompassing functional tumour imaging, tumour control predictions, inverse treatment planning and intensity modulated radiotherapy (IMRT) were presented. Dynamic contrast enhanced magnetic resonance imaging (DCEMRI) of a spontaneous sarcoma in the nasal region of a dog was employed. The tracer concentration in the tumour was assumed related to the oxygen tension and compared to Eppendorf histograph measurements. Based on the pO2-related images derived from the MR analysis, the tumour was divided into four compartments by a segmentation procedure. DICOM structure sets for IMRT planning could be derived thereof. In order to display the possible advantages of non-uniform tumour doses, dose redistribution among the four tumour compartments was introduced. The dose redistribution was constrained by keeping the average dose to the tumour equal to a conventional target dose. The compartmental doses yielding optimum tumour control probability (TCP) were used as input in an inverse planning system, where the planning basis was the pO2-related tumour images from the MR analysis. Uniform (conventional) and non-uniform IMRT plans were scored both physically and biologically. The consequences of random and systematic errors in the compartmental images were evaluated. The normalized frequency distributions of the tracer concentration and the pO2 Eppendorf measurements were not significantly different. 28% of the tumour had, according to the MR analysis, pO2 values of less than 5 mm Hg. The optimum TCP following a non-uniform dose prescription was about four times higher than that following a uniform dose prescription. The non-uniform IMRT dose distribution resulting from the inverse planning gave a three times higher TCP than that of the uniform distribution. The TCP and the dose-based plan quality depended on IMRT parameters defined in the inverse planning procedure (fields

  8. AMP-guided tumour-specific nanoparticle delivery via adenosine A1 receptor.

    Science.gov (United States)

    Dai, Tongcheng; Li, Na; Han, Fajun; Zhang, Hua; Zhang, Yuanxing; Liu, Qin

    2016-03-01

    Active targeting-ligands have been increasingly used to functionalize nanoparticles for tumour-specific clinical applications. Here we utilize nucleotide adenosine 5'-monophosphate (AMP) as a novel ligand to functionalize polymer-based fluorescent nanoparticles (NPs) for tumour-targeted imaging. We demonstrate that AMP-conjugated NPs (NPs-AMP) efficiently bind to and are following internalized into colon cancer cell CW-2 and breast cancer cell MDA-MB-468 in vitro. RNA interference and inhibitor assays reveal that the targeting effects mainly rely on the specific binding of AMP to adenosine A1 receptor (A1R), which is greatly up-regulated in cancer cells than in matched normal cells. More importantly, NPs-AMP specifically accumulate in the tumour site of colon and breast tumour xenografts and are further internalized into the tumour cells in vivo via tail vein injection, confirming that the high in vitro specificity of AMP can be successfully translated into the in vivo efficacy. Furthermore, NPs-AMP exhibit an active tumour-targeting behaviour in various colon and breast cancer cells, which is positively related to the up-regulation level of A1R in cancer cells, suggesting that AMP potentially suits for more extensive A1R-overexpressing cancer models. This work establishes AMP to be a novel tumour-targeting ligand and provides a promising strategy for future diagnostic or therapeutic applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Negative argininosuccinate synthetase expression in melanoma tumours may predict clinical benefit from arginine-depleting therapy with pegylated arginine deiminase

    Science.gov (United States)

    Feun, L G; Marini, A; Walker, G; Elgart, G; Moffat, F; Rodgers, S E; Wu, C J; You, M; Wangpaichitr, M; Kuo, M T; Sisson, W; Jungbluth, A A; Bomalaski, J; Savaraj, N

    2012-01-01

    Background: Arginine-depleting therapy with pegylated arginine deiminase (ADI-PEG20) was reported to have activity in advanced melanoma in early phase I–II trial, and clinical trials are currently underway in other cancers. However, the optimal patient population who benefit from this treatment is unknown. Methods: Advanced melanoma patients with accessible tumours had biopsy performed before the start of treatment with ADI-PEG20 and at the time of progression or relapse when amenable to determine whether argininosuccinate synthetase (ASS) expression in tumour was predictive of response to ADI-PEG20. Results: Twenty-seven of thirty-eight patients treated had melanoma tumours assessable for ASS staining before treatment. Clinical benefit rate (CBR) and longer time to progression were associated with negative expression of tumour ASS. Only 1 of 10 patients with ASS-positive tumours (ASS+) had stable disease, whereas 4 of 17 (24%) had partial response and 5 had stable disease, when ASS expression was negative (ASS−), giving CBR rates of 52.9 vs 10%, P=0.041. Two responding patients with negative ASS expression before therapy had rebiopsy after tumour progression and the ASS expression became positive. The survival of ASS− patients receiving at least four doses at 320 IU m−2 was significantly better than the ASS+ group at 26.5 vs 8.5 months, P=0.024. Conclusion: ADI-PEG20 is safe and the drug is only efficacious in melanoma patients whose tumour has negative ASS expression. Argininosuccinate synthetase tumour positivity is associated with drug resistance and tumour progression. PMID:22472884

  10. Tumour targeting with systemically administered bacteria.

    LENUS (Irish Health Repository)

    Morrissey, David

    2012-01-31

    Challenges for oncology practitioners and researchers include specific treatment and detection of tumours. The ideal anti-cancer therapy would selectively eradicate tumour cells, whilst minimising side effects to normal tissue. Bacteria have emerged as biological gene vectors with natural tumour specificity, capable of homing to tumours and replicating locally to high levels when systemically administered. This property enables targeting of both the primary tumour and secondary metastases. In the case of invasive pathogenic species, this targeting strategy can be used to deliver genes intracellularly for tumour cell expression, while non-invasive species transformed with plasmids suitable for bacterial expression of heterologous genes can secrete therapeutic proteins locally within the tumour environment (cell therapy approach). Many bacterial genera have been demonstrated to localise to and replicate to high levels within tumour tissue when intravenously (IV) administered in rodent models and reporter gene tagging of bacteria has permitted real-time visualisation of this phenomenon. Live imaging of tumour colonising bacteria also presents diagnostic potential for this approach. The nature of tumour selective bacterial colonisation appears to be tumour origin- and bacterial species- independent. While originally a correlation was drawn between anaerobic bacterial colonisation and the hypoxic nature of solid tumours, it is recently becoming apparent that other elements of the unique microenvironment within solid tumours, including aberrant neovasculature and local immune suppression, may be responsible. Here, we consider the pre-clinical data supporting the use of bacteria as a tumour-targeting tool, recent advances in the area, and future work required to develop it into a beneficial clinical tool.

  11. Molecular-based tumour subtypes of canine mammary carcinomas assessed by immunohistochemistry

    Directory of Open Access Journals (Sweden)

    Sarli Giuseppe

    2010-01-01

    Full Text Available Abstract Background Human breast cancer is classified by gene expression profile into subtypes consisting of two hormone (oestrogen and/or progesterone receptor-positive types (luminal-like A and luminal-like B and three hormone receptor-negative types [human epidermal growth factor receptor 2-expressing, basal-like, and unclassified ("normal-like"]. Immunohistochemical surrogate panels are also proposed to potentially identify the molecular-based groups. The present study aimed to apply an immunohistochemical panel (anti-ER, -PR, -ERB-B2, -CK 5/6 and -CK14 in a series of canine malignant mammary tumours to verify the molecular-based classification, its correlation with invasion and grade, and its use as a prognostic aid in veterinary practice. Results Thirty-five tumours with luminal pattern (ER+ and PR+ were subgrouped into 13 A type and 22 B type, if ERB-B2 positive or negative. Most luminal-like A and basal-like tumours were grade 1 carcinomas, while the percentage of luminal B tumours was higher in grades 2 and 3 (Pearson Chi-square P = 0.009. No difference in the percentage of molecular subtypes was found between simple and complex/mixed carcinomas (Pearson Chi-square P = 0.47. No significant results were obtained by survival analysis, even if basal-like tumours had a more favourable prognosis than luminal-like lesions. Conclusion The panel of antibodies identified only three tumour groups (luminal-like A and B, and basal-like in the dog. Even though canine mammary tumours may be a model of human breast cancer, the existence of the same carcinoma molecular subtypes in women awaits confirmation. Canine mammary carcinomas show high molecular heterogeneity, which would benefit from a classification based on molecular differences. Stage and grade showed independent associations with survival in the multivariate regression, while molecular subtype grouping and histological type did not show associations. This suggests that caution should be

  12. Tumour and tumour-like lesions of the patella - a multicentre experience

    International Nuclear Information System (INIS)

    Singh, J.; James, S.L.; Davies, A.M.; Kroon, H.M.; Woertler, K.; Anderson, S.E.

    2009-01-01

    Fifty-nine cases of lesions presenting in the patella were identified after review of the databases of four European bone tumour registries. Of the 59 cases, 46% were non neoplastic, 39% were benign and 15% were malignant. The commonest benign neoplasm was giant cell tumour (GCT) (11 cases). Younger patients were more likely to have a benign neoplasm. Lesions in patients less than 40 years of age included giant cell tumour, chondroblastoma, aneurysmal bone cyst (ABC), osteomyelitis, osteoid osteoma and solitary bone cyst. In patients older than 40 years, the following were common lesions: intra-osseous gout, metastasis and intra-osseous ganglion. Expansion of the patella with thinning of cortex was seen more commonly in GCT and brown tumour in hyperparathyroidism. There was associated soft tissue extension in gout and malignant lesions. (orig.)

  13. Tumour and tumour-like lesions of the patella - a multicentre experience

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J.; James, S.L.; Davies, A.M. [The Royal Orthopaedic Hospital, Department of Radiology, Birmingham (United Kingdom); Kroon, H.M. [Leiden University Medical Centre, Department of Radiology, C-2-S, P. O Box 9600, Leiden (Netherlands); Woertler, K. [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Anderson, S.E. [Knochentumor- Referenzzentrum der Schweizerischen Gesellschaft fuer Pathologie, Basel (Switzerland)

    2009-03-15

    Fifty-nine cases of lesions presenting in the patella were identified after review of the databases of four European bone tumour registries. Of the 59 cases, 46% were non neoplastic, 39% were benign and 15% were malignant. The commonest benign neoplasm was giant cell tumour (GCT) (11 cases). Younger patients were more likely to have a benign neoplasm. Lesions in patients less than 40 years of age included giant cell tumour, chondroblastoma, aneurysmal bone cyst (ABC), osteomyelitis, osteoid osteoma and solitary bone cyst. In patients older than 40 years, the following were common lesions: intra-osseous gout, metastasis and intra-osseous ganglion. Expansion of the patella with thinning of cortex was seen more commonly in GCT and brown tumour in hyperparathyroidism. There was associated soft tissue extension in gout and malignant lesions. (orig.)

  14. [Surgical Management of Peritoneal Surface Malignancy with Respect to Tumour Type, Tumour Stage and Individual Tumour Biology].

    Science.gov (United States)

    Beckert, S; Struller, F; Grischke, E-M; Glatzle, J; Zieker, D; Königsrainer, A; Königsrainer, I

    2016-08-01

    Peritoneal tumour dissemination is still considered as a terminal disease. For the last two decades, cytoreductive surgery (CRS) combined with intraoperative hyperthermic chemotherapy (HIPEC) has been popularised by Paul Sugarbaker almost doubling survival in selected patients compared with systemic chemotherapy alone. Nowadays, this particular treatment protocol is available in comprehensive cancer centres with reasonable mortality and morbidity. However, patient selection is still challenging. In general, CRS and HIPEC is indicated in primary peritoneal tumours such as mesothelioma and pseudomyxoma peritonei as well as in peritoneal metastases derived from gastrointestinal malignancies and ovarian cancers. Since systemic tumour spread is uncommon in patients with peritoneal metastases, peritoneal tumour dissemination was defined as localised disease within the "compartment abdomen". However, CRS and HIPEC are only beneficial as long as complete cytoreduction is achieved (CC-0 or CC-1). Histopathological parameters, the Sugarbaker peritoneal carcinomatosis index (PCI) and general condition of the patient have been established as patient selection criteria. In primary peritoneal cancers, individual tumour biology is the predominant criterium for patient selection as opposed to intraabdominal tumour load in peritoneal metastases derived from gastrointestinal cancers. In gastric cancer, CRS and HIPEC should be restricted to synchronous limited disease because of its biological aggressiveness. In patients with free floating cancer cells without macroscopic signs of peritoneal spread, however, CRS and HIPEC following preoperative "neoadjuvant" chemotherapy preserves chances for cure. So far, there is no general recommendation for CRS and HIPEC by clinical practice guidelines. In the recent S3 guideline for treatment of colorectal cancer, however, CRS and HIPEC have been included as possible treatment options. Georg Thieme Verlag KG Stuttgart · New York.

  15. Diagnostic value of somatostatin receptor scintigraphy in patients with intracranial tumours

    International Nuclear Information System (INIS)

    Luyken, C.; Hildebrandt, G.; Scheidhauer, K.; Kirsch, B.

    1993-01-01

    The aim of the study was to detect the SR binding sites in intracranial tumours and to evaluate the benefit of SRS in pre- and postoperative diagnostics. 86 patients with 94 intracranial tumours (39 meningiomas, 18 pituitary adenomas, 11 gliomas grade 3 or 4, 8 gliomas grade 2, 5 neurinomas, 5 intracranial metastases, 4 tumours of the orbit, 2 neurofibromas, 1 brain abscess and 1 cystic lesion) were examined. 111 In-octreotide was injected i.v. as 10 μg or 20 μg bolus, corresponding to 110 or 220 MBq (3 or 6 mCi). Gamma-camera images and SPECT were obtained 3-6 h and 24 h post injection. The scintigraphic evaluation was performed without knowledge of CT and MRI results. The histological classification corresponded to the WHO grading system. Somatostatin binding sites were detected in vito using somatostatin-gold conjugates. All patients with meningiomas showed a high focal tracer uptake corresponding to SR binding sites in vitro, whereas only in 50% of the pituitary adenomas SRS was positive. Neurinomas did not show any tracer uptake. In patients with gliomas with disturbed blood-brain-barrier positive tracer uptake was detected, while none of the gliomas with intact blood-brain-barrier could be visualized by SRS but showed somatostatin binding sites in vitro. In intracranial metastases a local tracer uptake was detected in vivo. In vitro 3 of 4 cases showed somatostatin binding sites. In 2 cases extracranial tracer uptake showed the primary tumour and metastases of the lymphnodes. Somatostatin receptor scintigraphy can help to detect or to exclude meningiomas especially in the cerebellopontine angle or in the orbit. In intracranial metastases SRS may point to the primary tumour or other metastases. In all other intracranial tumours receptor scintigraphy provides no clinical relevant information. (orig./MG) [de

  16. Recurrence and mortality according to Estrogen Receptor status for breast cancer patients undergoing conservative surgery. Ipsilateral breast tumour recurrence dynamics provides clues for tumour biology within the residual breast

    International Nuclear Information System (INIS)

    Demicheli, Romano; Ardoino, Ilaria; Boracchi, Patrizia; Coradini, Danila; Agresti, Roberto; Ferraris, Cristina; Gennaro, Massimiliano; Hrushesky, William JM; Biganzoli, Elia

    2010-01-01

    the study was designed to determine how tumour hormone receptor status affects the subsequent pattern over time (dynamics) of breast cancer recurrence and death following conservative primary breast cancer resection. Time span from primary resection until both first recurrence and death were considered among 2825 patients undergoing conservative surgery with or without breast radiotherapy. The hazard rates for ipsilateral breast tumour recurrence (IBTR), distant metastasis (DM) and mortality throughout 10 years of follow-up were assessed. DM dynamics displays the same bimodal pattern (first early peak at about 24 months, second late peak at the sixth-seventh year) for both estrogen receptor (ER) positive (P) and negative (N) tumours and for all local treatments and metastatic sites. The hazard rates for IBTR maintain the bimodal pattern for ERP and ERN tumours; however, each IBTR recurrence peak for ERP tumours is delayed in comparison to the corresponding timing of recurrence peaks for ERN tumours. Mortality dynamics is markedly different for ERP and ERN tumours with more early deaths among patients with ERN than among patients with ERP primary tumours. DM dynamics is not influenced by the extent of conservative primary tumour resection and is similar for both ER phenotypes across different metastatic sites, suggesting similar mechanisms for tumour development at distant sites despite apparently different microenvironments. The IBTR risk peak delay observed in ERP tumours is an exception to the common recurrence risk rhythm. This suggests that the microenvironment within the residual breast tissue may enforce more stringent constraints upon ERP breast tumour cell growth than other tissues, prolonging the latency of IBTR. This local environment is, however, apparently less constraining to ERN cells, as IBTR dynamics is similar to the corresponding recurrence dynamics among other distant tissues

  17. Vaginal haemangioendothelioma: an unusual tumour.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Vaginal tumours are uncommon and this is a particularly rare case of a vaginal haemangioendothelioma in a 38-year-old woman. Initial presentation consisted of symptoms similar to uterovaginal prolapse with "something coming down". Examination under anaesthesia demonstrated a necrotic anterior vaginal wall tumour. Histology of the lesion revealed a haemangioendothelioma which had some features of haemangiopericytoma. While the natural history of vaginal haemangioendothelioma is uncertain, as a group, they have a propensity for local recurrence. To our knowledge this is the third reported case of a vaginal haemangioendothelioma. Management of this tumour is challenging given the paucity of literature on this tumour. There is a need to add rare tumours to our "knowledge bank" to guide management of these unusual tumours.

  18. of brain tumours

    African Journals Online (AJOL)

    outline of the important clinical issues related to brain tumours and psychiatry. ... Left-sided, frontal tumours also seem to be associated with higher rates of depression, while those in the frontal lobe of the right .... Oxford: Blackwell Science,.

  19. Value of skeletal scintiscanning in cases of primary bone tumours and tumourous alterations

    International Nuclear Information System (INIS)

    Sokolowski, U.

    1982-01-01

    In the course of an investigation on the storage behaviour of primary bone tumours and tumourous bone alterations the skeletal scintigrams of a total of 26 patients were evaluated. Bone scintiscanning was done according to current practice after injection of an average amount of 10mCi sup(99m)Tc-MDP, followed by a semiquantitative evaluation. In all cases of malignant bone tumours there was fond to be increased storage of radionuclide; with benign bone alterations this was so in 70 per cent of cases. To differentiate between benign and malignant tumours respectively inflammatory bone diseases was not as a rule possible; however, the investigation yielded additional information completing the X-ray findings essentially. Thus very high storage of radioactivity was established for all osteosarcomas, whereas benign bone growths exhibited more circumscribed accumulations of activity. Skeletal scintiscanning for diagnostical purposes is particularly informative as to the early detection of bone foci evading X-ray diagnosis, more accurate delimitation of tumourous processes, and course control of tumours tending to degenerate. (orig./MG) [de

  20. Management of parapharyngeal space tumours

    International Nuclear Information System (INIS)

    Ahmad, F.; Waqar-Uddin; Khan, M.S.; Khawar, A.; Bangush, W.; Aslam, J.

    2006-01-01

    Objective: To determine the role of clinical features, fine needle aspiration cytology (FNAC) and computed tomography (CT) scan in diagnosing Para pharyngeal space (PPS) tumours and treatment options. Design: A descriptive study. Place and Duration of Study: From July 2000 to July 2002 at Pakistan Institute of Medical Sciences, Islamabad. Patients and Methods: Patients diagnosed as having PPS tumours were studied. The medical record of patients was reviewed for their age, gender, clinical features, investigations (FNAC and CT scan) and treatment. The mean age, percentage of different clinical features and the sensitivity and specificity of FNAC was determined. Results: The mean age of patients presenting with PPS tumours was 33.6 years. The most common clinical features were neck mass (93%) and bulge in lateral pharyngeal wall (80%). The CT scan showed exact location and extent of tumour in 11 out of 15 cases. The sensitivity and specificity of FNAC was 70% and 85% respectively. The most common tumours were neurogenic tumours and salivary gland tumours. Surgery was performed in all except 2 patients with lymphoma in whom radiation and chemotherapy was recommended. Conclusion: This study indicates that PPS tumours are usually benign neurosurgeon and salivary gland tumours presenting with neck mass and bulge in or oropharynx. FNAC and CT scan are important in diagnostic work up and treatment planning. Surgery has the best results in most cases. (author)

  1. Sperm protein 17 is expressed in human nervous system tumours

    International Nuclear Information System (INIS)

    Grizzi, Fabio; Baena, Riccardo Rodriguez y; Dioguardi, Nicola; Chiriva-Internati, Maurizio; Gaetani, Paolo; Franceschini, Barbara; Di Ieva, Antonio; Colombo, Piergiuseppe; Ceva-Grimaldi, Giorgia; Bollati, Angelo; Frezza, Eldo E; Cobos, E

    2006-01-01

    Human sperm protein 17 (Sp17) is a highly conserved protein that was originally isolated from a rabbit epididymal sperm membrane and testis membrane pellet. It has recently been included in the cancer/testis (CT) antigen family, and shown to be expressed in multiple myeloma and ovarian cancer. We investigated its immunolocalisation in specimens of nervous system (NS) malignancies, in order to establish its usefulness as a target for tumour-vaccine strategies. The expression of Sp17 was assessed by means of a standardised immunohistochemical procedure [(mAb/antigen) MF1/Sp17] in formalin-fixed and paraffin embedded surgical specimens of NS malignancies, including 28 neuroectodermal primary tumours (6 astrocytomas, 16 glioblastoma multiforme, 5 oligodendrogliomas, and 1 ependymoma), 25 meningeal tumours, and five peripheral nerve sheath tumours (4 schwannomas, and 1 neurofibroma),. A number of neuroectodermal (21%) and meningeal tumours (4%) were found heterogeneously immunopositive for Sp17. None of the peripheral nerve sheath tumours was immunopositive for Sp17. The expression pattern was heterogeneous in all of the positive samples, and did not correlate with the degree of malignancy. The frequency of expression and non-uniform cell distribution of Sp17 suggest that it cannot be used as a unique immunotherapeutic target in NS cancer. However, our results do show the immunolocalisation of Sp17 in a proportion of NS tumour cells, but not in their non-pathological counterparts. The emerging complex function of Sp17 makes further studies necessary to clarify the link between it and immunopositive cells

  2. [Neonatal tumours and congenital malformations].

    Science.gov (United States)

    Berbel Tornero, O; Ortega García, J A; Ferrís i Tortajada, J; García Castell, J; Donat i Colomer, J; Soldin, O P; Fuster Soler, J L

    2008-06-01

    The association between pediatric cancer and congenital abnormalities is well known but, there is no exclusive data on the neonatal period and the underlying etiopathogenic mechanisms are unknown. First, to analyze the frequency of neonatal tumours associated with congenital abnormalities; and second, to comment on the likely etiopathogenic hypotheses of a relationship between neonatal tumours and congenital abnormalities. Historical series of neonatal tumours from La Fe University Children's Hospital in Valencia (Spain), from January 1990 to December 1999. Histological varieties of neonatal tumours and associated congenital abnormalities were described. A systematic review of the last 25 years was carried out using Medline, Cancerlit, Index Citation Science and Embase. The search profile used was the combination of "neonatal/congenital-tumors/cancer/neoplasms" and "congenital malformations/birth defects". 72 neonatal tumours were identified (2.8% of all pediatric cancers diagnosed in our hospital) and in 15 cases (20.8%) there was some associated malformation, disease or syndrome. The association between congenital abnormalities and neonatal tumours were: a) angiomas in three patients: two patients with congenital heart disease with a choanal stenosis, laryngomalacia; b) neuroblastomas in two patients: horseshoe kidney with vertebral anomalies and other with congenital heart disease; c) teratomas in two patients: one with cleft palate with vertebral anomalies and other with metatarsal varus; d) one tumour of the central nervous system with Bochdaleck hernia; e) heart tumours in four patients with tuberous sclerosis; f) acute leukaemia in one patient with Down syndrome and congenital heart disease; g) kidney tumour in one case with triventricular hydrocephaly, and h) adrenocortical tumour: hemihypertrophy. The publications included the tumours diagnosed in different pediatric periods and without unified criteria to classify the congenital abnormalities. Little data

  3. Comparison of metastatic disease after local tumour treatment with radiotherapy or surgery in various tumour models

    International Nuclear Information System (INIS)

    Ruiter, J. de; Cramer, S.J.; Lelieveld, P.; Putten, L.M. van

    1982-01-01

    Spontaneous metastases in lymph nodes and/or the lung were obtained after tumour cell inoculation of four mouse tumours and one rat tumour into the foot-pads of syngeneic animals or their F 1 hybrids. Following local radiotherapy with doses of 45-80 Gy, significantly more mice died with metastases than following local amputation of the tumour-bearing foot when the 2661 carcinoma was involved. No significant difference was observed after these treatments for the other tumours. The enhancement of metastatic growth after local radiotherapy in the 2661 carcinoma seems not to be due to incomplete killing of tumour cells in the foot. The presence of irradiated normal structures and tumour tissue after radiotherapy promoted the outgrowth of 2661 carcinoma cells which were outside the radiation field at the time of treatment. Evidently, even under similar experimental conditions, radiotherapy may enhance the growth of metastases from some tumours and not from others. (author)

  4. Id1 suppresses anti-tumour immune responses and promotes tumour progression by impairing myeloid cell maturation.

    Science.gov (United States)

    Papaspyridonos, Marianna; Matei, Irina; Huang, Yujie; do Rosario Andre, Maria; Brazier-Mitouart, Helene; Waite, Janelle C; Chan, April S; Kalter, Julie; Ramos, Ilyssa; Wu, Qi; Williams, Caitlin; Wolchok, Jedd D; Chapman, Paul B; Peinado, Hector; Anandasabapathy, Niroshana; Ocean, Allyson J; Kaplan, Rosandra N; Greenfield, Jeffrey P; Bromberg, Jacqueline; Skokos, Dimitris; Lyden, David

    2015-04-29

    A central mechanism of tumour progression and metastasis involves the generation of an immunosuppressive 'macroenvironment' mediated in part through tumour-secreted factors. Here we demonstrate that upregulation of the Inhibitor of Differentiation 1 (Id1), in response to tumour-derived factors, such as TGFβ, is responsible for the switch from dendritic cell (DC) differentiation to myeloid-derived suppressor cell expansion during tumour progression. Genetic inactivation of Id1 largely corrects the myeloid imbalance, whereas Id1 overexpression in the absence of tumour-derived factors re-creates it. Id1 overexpression leads to systemic immunosuppression by downregulation of key molecules involved in DC differentiation and suppression of CD8 T-cell proliferation, thus promoting primary tumour growth and metastatic progression. Furthermore, advanced melanoma patients have increased plasma TGFβ levels and express higher levels of ID1 in myeloid peripheral blood cells. This study reveals a critical role for Id1 in suppressing the anti-tumour immune response during tumour progression and metastasis.

  5. Diagnostic utility of Wilms′ tumour-1 protein (WT-1 immunostaining in paediatric renal tumours

    Directory of Open Access Journals (Sweden)

    Surbhi Goyal

    2016-01-01

    Interpretation & conclusions: WT1 helps to differentiate Wilms′ tumour from other paediatric renal tumours. It may help in differentiating the two subgroups of Wilms′ tumour which have distinct molecular pathogenesis and biological behaviour, however, further prospective studies are required for validation of this hypothesis.

  6. Immunization with MHC class I-negative but not -positive HPV16-associated tumour cells inhibits growth of MHC class I-negative tumours

    Czech Academy of Sciences Publication Activity Database

    Reiniš, Milan; Šímová, Jana; Indrová, Marie; Bieblová, Jana; Přibylová, Hana; Moravcová, Simona; Jandlová, Táňa; Bubeník, Jan

    2007-01-01

    Roč. 30, č. 4 (2007), s. 1011-1017 ISSN 1019-6439 R&D Projects: GA MZd NR7807 EU Projects: European Commission(XE) 18933 - CLINIGENE Grant - others:Liga proti rakovině, Praha(CZ) XX Institutional research plan: CEZ:AV0Z50520514 Keywords : HPV16 * MHC class I-deficient tumours * immunologic crossreaction Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.295, year: 2007

  7. Targeting of breast metastases using a viral gene vector with tumour-selective transcription.

    LENUS (Irish Health Repository)

    Rajendran, Simon

    2012-01-31

    BACKGROUND: Adeno-associated virus (AAV) vectors have significant potential as gene delivery vectors for cancer gene therapy. However, broad AAV2 tissue tropism results in nonspecific gene expression. MATERIALS AND METHODS: We investigated use of the C-X-C chemokine receptor type 4 (CXCR4) promoter to restrict AAV expression to tumour cells, in subcutaneous MCF-7 xenograft mouse models of breast cancer and in patient samples, using bioluminescent imaging and flow cytometric analysis. RESULTS: Higher transgene expression levels were observed in subcutaneous MCF-7 tumours relative to normal tissue (muscle) using the CXCR4 promoter, unlike a ubiquitously expressing Cytomegalovirus promoter construct, with preferential AAVCXCR4 expression in epithelial tumour and CXCR4-positive cells. Transgene expression following intravenously administered AAVCXCR4 in a model of liver metastasis was detected specifically in livers of tumour bearing mice. Ex vivo analysis using patient samples also demonstrated higher AAVCXCR4 expression in tumour compared with normal liver tissue. CONCLUSION: This study demonstrates for the first time, the potential for systemic administration of AAV2 vector for tumour-selective gene therapy.

  8. Assessment of quantitative FDG PET data in primary colorectal tumours: which parameters are important with respect to tumour detection?

    International Nuclear Information System (INIS)

    Strauss, Ludwig G.; Pan, Leyun; Dimitrakopoulou-Strauss, Antonia; Klippel, Sven; Schoenleben, Klaus; Haberkorn, Uwe

    2007-01-01

    The impact of quantitative parameters on the differentiation of primary colorectal tumours from normal colon tissue was assessed. Dynamic PET data (DPET) were acquired, and compartment and non-compartment modelling applied. The discriminant power of single parameters and the combination of PET parameters was assessed. All lesions were confirmed by histology. FDG DPET studies were acquired in 22 patients with colorectal tumours prior to surgery. Five of these patients also had liver metastases at the time of the PET study. The SUV 56-60 min p.i. was included in the evaluation. A two-tissue compartment model was applied and the parameters k 1 -k 4 as well as the fractional blood volume (V B ) were obtained. The FDG influx was calculated from the compartment data. Non-compartment modelling was used to calculate the fractal dimension (FD) of the time-activity data. FD, SUV, influx and k 3 were the most important single parameters for lesion differentiation. The highest accuracy was achieved for FD (88.78%). The overall tracer uptake was mainly dependent on k 3 and not on k 1 or V B . The support vector machines (SVM) algorithm was used to predict the classification based on the combination of individual PET parameters. The overall accuracy was 97.3%, with only one false positive case and no false negative results. The analysis of the subgroup of five patients with primary tumours and synchronous metastases revealed no significant differences for the individual PET parameters. However, V B tended to be lower while k 1 and k 2 were higher in patients with synchronous metastases. The SVM classification analysis predicted the presence of metastases based on the PET data of the primary tumour in three of five patients. Quantitative FDG PET studies provide very accurate data for the differentiation of primary colorectal tumours from normal tissue. The use of quantitative data has the advantage that the detection of a colorectal tumour is not primarily dependent on the

  9. Radiodiagnosis of tumours of gastrointestinal tract

    International Nuclear Information System (INIS)

    Sokolov, Yu.N.; Antonovich, V.B.

    1981-01-01

    Systematic description of X-ray picture of tumours of gastrointestinal tract organs is given. The possibilities of contemporary methods of X-ray examination in their revealing are shown. Clinical and X-ray trend of tumour diagnosis is underlined. The basic and accessory symptoms are analyzed from which X-ray semiotics of tumours is turned out. The expressiveness of X-ray symptoms is shown in relation to morphological forms and localization of the tumours. Much attention is given to radiodiagnosis of early tumours of stomach. Differential diagnosis of tumours with non-tumoural diseases is given. X-ray semiotics of lesions of gastrointestinal tract organs in malignant diseases of blood system is presented [ru

  10. Malignant thyroid tumours

    International Nuclear Information System (INIS)

    Boerner, W.; Reiners, C.

    1987-01-01

    The subjects dealt with at the symposium cover all topical aspects of pathology, epidemiology, diagnosis, therapy, and aftercare of the malignant thyroid tumours. A survey of the histological classification of the thyroid tumours and a review of the latest findings concerning the radiocarcinogenesis are followed by a detailed discussion of the most significant tumours. There are also papers dealing with controversial aspects of the histological classification, the value of diagnostic methods, radicality of the therapy, or after care. For five conference papers, separate records are available in the database. (orig./ECB) With 59 figs.; 57 tabs [de

  11. CRIO-INFLUENCE IN SURGICAL TREATMENT OF BENIGN TUMOURS OF FOOT BONES

    Directory of Open Access Journals (Sweden)

    S. V. Dianov

    2010-01-01

    Full Text Available The material of investigation was the results of treatment of 131 patients with foot bones tumours. The largest number of patients referred, to age interval from 11 to 30 years (69,6%. More than half of cases were osteochondromas (54%, then solitary bone cyst (14,5% and chondromas (13%. Other nosologic forms were met significantly seldom. Two groups of patients were examined: the main group (with crio-influence - 44 patients and group of comparison (without crio-influence - 87 patients. The plot of operation was in flat, border-line, intrafocusal or segmental resection of damaged section, crio-instillation or contact curio-processing of bone and auto- or allopathic of respected defect. The results of treatment were estimated in a year after operation. After usage of curio-surgical method there were observed positive results in 41 patients, satisfactory - in 2 and unsatisfactory - in 1. The results of treatment with traditional method were positive in 79 cases, satisfactory - in 2, unsatisfactory - in 6. The worked-out method of curio-surgical treatment of foot bone tumours includes resection of pathological focus, itraoperative crio-influence on bone tissue and bone plastic transplantation of resected, defect. The analysis of criosurgical operations of foot gave the foundation to consider such interventions significant and perspective in treatment of patients with tumours and tumour similar damages of foot bone.

  12. SU-E-J-171: Surface Imaging Based Intrafraction Motion Assessments for Whole Brain Radiotherapy

    International Nuclear Information System (INIS)

    Wiant, D; Vanderstraeten, C; Maurer, J; Pursley, J; Terrell, J; Sintay, B

    2014-01-01

    Purpose: To quantify and characterize intrafraction motion for whole brain radiotherapy treatments in open face masks using 3D surface imaging. Methods: Fifteen whole brain patients were monitored with 3D surface imaging over a total of 202 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 1.45 mm +/− 1.52 mm. The patients spent an average of 18%, 10%, 6%, and 3% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 1.31 mm +/− 0.98 mm, 1.52 +/- 1.04, and 1.30 mm +/− 0.71 mm over the 1th, 5th, and 10th minutes of monitoring, respectively. Neither, the RMS values (p = 0.15) or the standard deviations of the RMS values (p = 0.16) showed significant correlations with time. Conclusion: The patients were positioned within 2 mm of isocenter, which was the initial set-up tolerance, for the majority of their treatments. The average position changed by < 0.3 mm over 10 minutes of monitoring. Short term movements, reflected by the standard deviations, where on the order of 1 mm. This immobilization system provides adequate immobilization over a course of treatment for whole brain radiotherapy. This system may also be suitable for head and neck or stereotactic radiosurgery treatments as well

  13. Teratoid Wilms tumour with chemotherapy resistance

    Directory of Open Access Journals (Sweden)

    Renuka Gahine

    2015-01-01

    Full Text Available We present a case of Teratoid Wilms tumour (a rare histologic variant in a 4 year old male who presented with an abdominal lump. Wilms Tumour with paracaval lymphadenopathy and tumour thrombi in right renal vein and inferior vena cava was made radiologically. FNAC report was suggestive of Wilms tumour and patient was subjected to 6 cycles of chemotherapy with not much reduction in size. Post nephrectomy histological diagnosis of Teratoid Wilms tumour was established. Resistance to chemotherapy and radiotherapy is thought to be due to presence of well differentiated histologic appearance. Teratoid Wilms tumour is usually not an aggressive neoplasm and prognosis is comparatively neoplasm and prognosis is comparatively good if the tumour is excised completely thus surgery being the best treatment.

  14. Impact of tumour volume on prediction of progression-free survival in sinonasal cancer

    International Nuclear Information System (INIS)

    Hennersdorf, Florian; Mauz, Paul-Stefan; Adam, Patrick; Welz, Stefan; Sievert, Anne; Ernemann, Ulrike; Bisdas, Sotirios

    2015-01-01

    The present study aimed to analyse potential prognostic factors, with emphasis on tumour volume, in determining progression free survival (PFS) for malignancies of the nasal cavity and the paranasal sinuses. Retrospective analysis of 106 patients with primary sinonasal malignancies treated and followed-up between March 2006 and October 2012. Possible predictive parameters for PFS were entered into univariate and multivariate Cox regression analysis. Kaplan-Meier curve analysis included age, sex, baseline tumour volume (based on MR imaging), histology type, TNM stage and prognostic groups according to the American Joint Committee on Cancer (AJCC) classification. Receiver operating characteristic (ROC) curve analysis concerning the predictive value of tumour volume for recurrence was also conducted. The main histological subgroup consisted of epithelial tumours (77%). The majority of the patients (68%) showed advanced tumour burden (AJCC stage III–IV). Lymph node involvement was present in 18 cases. The mean tumour volume was 26.6 ± 21.2 cm 3 . The median PFS for all patients was 24.9 months (range: 2.5–84.5 months). The ROC curve analysis for the tumour volume showed 58.1% sensitivity and 75.4% specificity for predicting recurrence. Tumour volume, AJCC staging, T- and N- stage were significant predictors in the univariate analysis. Positive lymph node status and tumour volume remained significant and independent predictors in the multivariate analysis. Radiological tumour volume proofed to be a statistically reliable predictor of PFS. In the multivariate analysis, T-, N- and overall AJCC staging did not show significant prognostic value

  15. Pentavalent 99Tcm - DMSA SPECT in primary brain tumours of glial cell origin

    International Nuclear Information System (INIS)

    Chung, D.K.; Evans, S.G.; Larcos, G.; Gruenewald, S.; Kumar, V.; Barton, M.

    1999-01-01

    Full text: 99 Tc m (V)-DMSA [DMSA(V)] has shown promise in brain tumour imaging. This study aimed to assess the role of DMSA(V) brain SPET in glioma for: (1) predicting the histopathological grade of malignancy, (2) monitoring response to therapy and (3) discriminating recurrent tumour from post-radiotherapy necrosis. Twenty-three patients (pts) (14 men, 9 women) of mean age 57 years (range 20-79) were referred with a lesion on CT/MRI (14 new presentations, 5 known and 4 suspected tumour recurrence). Up to 555 MBq of 99 Tc m (V)DMSA were administered and SPET was acquired at 3 h. Tumour uptake ratio (UR) was calculated by the ratio of activity in the tumour to a region in the contralateral brain. All 19 pts with known tumour showed DMSA(V) uptake. The 14 pts with new tumours (10 grade IV, I grade III, 2 grade II and 1 necrotic tumour) had a pre-therapy mean UR of 7.7 (range 2.8-13.6). The 3 lower-grade tumours were scattered widely within this range. Four pts completed radiotherapy and returned for a post-therapy scan, where the UR was less than the pre-therapy UR in 2, unchanged in 1 and greater in 1. The 5 known recurrent tumours had a mean UR of 13.5 (range 7.3-24.9). In the 4 pts with suspected recurrence, the DMSA(V) scan result agreed with clinical course or PET in 3 but was falsely positive in 1. In summary, 99 Tc m (V)-DMSA: (1) showed uptake in all known glial cell tumours in this series, however the UR did not correlate with the histopathological grade; (2) may be useful for discriminating tumour recurrence from post-radiotherapy necrosis; and (3) may have a role in predicting post-therapy prognosis

  16. Extrarenal rhabdoid tumours outside the central nervous system in infancy

    Energy Technology Data Exchange (ETDEWEB)

    Garces-Inigo, Enrique F. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Complejo Hospitalario Universitario de Albacete, Radiology Department, Hermanos Falco, Albacete (Spain); Leung, Rebecca; McHugh, Kieran [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Sebire, Neil J. [Great Ormond Street Hospital for Children, Department of Histopathology, London (United Kingdom)

    2009-08-15

    Malignant rhabdoid tumours (RT) are increasingly recognized in young children, probably as a consequence of advances in accurate histological diagnosis rather than a true increase in frequency. Although typically presenting as renal tumours in infancy, extrarenal tumours outside the central nervous system (CNS) in children less than 12 months of age are now well recognized, but previous literature on their imaging features is very limited. To demonstrate the imaging features of extrarenal RTs outside the CNS. A retrospective database review was made from 1989 to 2007 of patients diagnosed with extrarenal RT in infancy, i.e. below 12 months of age. There were nine patients (six boys and three girls). The age at presentation varied from 1 to 11 months (average 6 months). Tumours were located in the thorax/mediastinum (n=3), liver (n=3), neck (n=1), shoulder (n=1) and axilla (n=1). The imaging modalities used included US (n=8), CT (n=7) and MRI (n=6). Bone scan was positive in one patient, while metastases at the time of diagnosis occurred in four patients. On MRI the tumours tended to show nonspecific hypointensity on T1-W images and heterogeneous hyperintensity on T2-W images, with heterogeneous enhancement. This is the largest radiological series of extrarenal RTs outside the CNS in infancy. In our series no imaging features were found specific to the diagnosis. A tendency towards large size and mediastinal/paravertebral location were noted. A hypodense solid component on CT and a heterogeneous hyperintensity on T2-W MR images suggest that this tumour should be considered in the routine differential diagnosis of soft-tissue tumours in infancy, in addition to rhabdomyosarcoma. (orig.)

  17. FNAC AS A DIAGNOSTIC TOOL IN SALIVARY GLAND TUMOURS

    Directory of Open Access Journals (Sweden)

    Kalivarapu

    2016-03-01

    Full Text Available BACKGROUND FNAC of salivary gland tumours is an accurate, simple, rapid, inexpensive, well tolerated and harmless procedure. The success of FNAC depends on the adequacy of sample and high-quality preparation. FNAC of salivary gland neoplasms provides essential information in decision making and management. AIM OF THE STUDY Know the role of fine needle aspiration cytology in the diagnosis of benign and malignant lesions of salivary gland. MATERIAL AND METHODS This was a prospective study done at the tertiary care centre for a period of three years. A total number of 67 cases of clinically suspected salivary gland tumours were subjected to fine needle aspiration cytology and correlated with histopathology. RESULTS A total number of 67 cases, clinically suspected as salivary gland tumours were subjected to FNAC and compared with histopathology. The observations of the study were as follows: Most of the tumours were observed between the age group of 31-40 years. The commonest gland involved was the parotid gland, 56 cases of benign, 10 cases of malignant and one case of inconclusive diagnosis was made on FNAC. In the present study, FNAC showed Sensitivity of 66.6%, Specificity of 98%, Positive predictive value; 90.9%, Negative predictive value; 91%, Percentage of false negative cases 33.3%, Percentage of false positive cases 1.9% and Overall Diagnostic Accuracy of 91%. CONCLUSION FNAC is a very useful, simple, cheap, accurate and repeatable technique in the preoperative diagnosis of various salivary gland neoplasms. Overall, diagnostic accuracy was 91%, in cystic lesions of salivary glands, combined FNAC and histopathology is essential for diagnosis.

  18. DOTA-PESIN, a DOTA-conjugated bombesin derivative designed for the imaging and targeted radionuclide treatment of bombesin receptor-positive tumours

    International Nuclear Information System (INIS)

    Zhang, Hanwen; Maecke, Helmut R.; Schuhmacher, Jochen; Eisenhut, Michael; Waser, Beatrice; Reubi, Jean Claude; Wild, Damian

    2007-01-01

    We aimed at designing and developing a novel bombesin analogue, DOTA-PEG 4 -BN(7-14) (DOTA-PESIN), with the goal of labelling it with 67/68 Ga and 177 Lu for diagnosis and radionuclide therapy of prostate and other human cancers overexpressing bombesin receptors. The 8-amino acid peptide bombesin (7-14) was coupled to the macrocyclic chelator DOTA via the spacer 15-amino-4,7,10,13-tetraoxapentadecanoic acid (PEG 4 ). The conjugate was complexed with Ga(III) and Lu(III) salts. The GRP receptor affinity and the bombesin receptor subtype profile were determined in human tumour specimens expressing the three bombesin receptor subtypes. Internalisation and efflux studies were performed with the human GRP receptor cell line PC-3. Xenografted nude mice were used for biodistribution. [Ga III /Lu III ]-DOTA-PESIN showed good affinity to GRP and neuromedin B receptors but no affinity to BB3. [ 67 Ga/ 177 Lu]-DOTA-PESIN internalised rapidly into PC-3 cells whereas the efflux from PC-3 cells was relatively slow. In vivo experiments showed a high and specific tumour uptake and good retention of [ 67 Ga/ 177 Lu]-DOTA-PESIN. [ 67 Ga/ 177 Lu]-DOTA-PESIN highly accumulated in GRP receptor-expressing mouse pancreas. The uptake specificity was demonstrated by blocking tumour uptake and pancreas uptake. Fast clearance was found from blood and all non-target organs except the kidneys. High tumour-to-normal tissue ratios were achieved, which increased with time. PET imaging with [ 68 Ga]-DOTA-PESIN was successful in visualising the tumour at 1 h post injection. Planar scintigraphic imaging showed that the 177 Lu-labelled peptide remained in the tumour even 3 days post injection. The newly designed ligands have high potential with regard to PET and SPECT imaging with 68/67 Ga and targeted radionuclide therapy with 177 Lu. (orig.)

  19. Field-In-Field Technique With Intrafractionally Modulated Junction Shifts for Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Yom, Sue S.; Frija, Erik K. C.; Mahajan, Anita; Chang, Eric; Klein, Kelli C.; Shiu, Almon; Ohrt, Jared; Woo, Shiao

    2007-01-01

    Purpose: To plan craniospinal irradiation with 'field-in-field' (FIF) homogenization in combination with daily, intrafractional modulation of the field junctions, to minimize the possibility of spinal cord overdose. Methods and Materials: Lateral cranial fields and posterior spinal fields were planned using a forward-planned, step-and-shoot FIF technique. Field junctions were automatically modulated and custom-weighted for maximal homogeneity within each treatment fraction. Dose-volume histogram analyses and film dosimetry were used to assess results. Results: Plan inhomogeneity improved with FIF. Planning with daily modulated junction shifts provided consistent dose delivery during each fraction of treatment across the junctions. Modulation minimized the impact of a 5-mm setup error at the junction. Film dosimetry confirmed that no point in the junction exceeded the anticipated dose. Conclusions: Field-in-field planning and modulated junction shifts improve the homogeneity and consistency of daily dose delivery, simplify treatment, and reduce the impact of setup errors

  20. Wilms' tumour (nephroblastoma)

    African Journals Online (AJOL)

    Wilms' tumour or nephroblastoma is a cancer of the kidney that ... It may be noticed by parents or it may be an incidental finding ... patients. It may lead to iron deficiency anaemia. Rarely Wilms' tumour may present with acquired von Willebrand's ... the best treatment approach. ... with multimodality therapy in paediatric.

  1. Facultative or obligate anaerobic bacteria have the potential for multimodality therapy of solid tumours.

    Science.gov (United States)

    Wei, Ming Q; Ellem, Kay A O; Dunn, Paul; West, Malcolm J; Bai, Chun Xue; Vogelstein, Bert

    2007-02-01

    Recent understanding of the unique pathology of solid tumours has shed light on the difficult and disappointing nature of their clinical treatment. All solid tumours undergo angiogenesis that results in biological changes and adaptive metabolisms, i.e. formation of defective vessels, appearance of hypoxic areas, and emergence of an heterogeneous tumour cell population. This micro-milieu provides a haven for anaerobic bacteria. The strictly anaerobic clostridia have several advantages over other facultative anaerobes such as salmonella or lactic acid-producing, Gram-positive, obligate, anaerobic bifidobacteria. Both pathogenic and non-pathogenic clostridia have been demonstrated to specifically colonise and destroy solid tumours. Early trials of non-pathogenic strains in humans had shown plausible safety. Genetic modifications and adaptation of pathogenic and non-pathogenic strains have further created improved features. However, these manipulations rarely generate strains that resulted in complete tumour control alone. Combined modalities of therapies with chemo and radiation therapies, on the other hand, often perform better, including 'cure' of solid tumours in a high percentage of animals. Considering that clostridia have unlimited capacities for genetic improvement, we predict that designer clostridia forecast a promising future for the development of potent strains for tumour destruction, incorporating mechanisms such as immunotherapy to overcome immune suppression and to elicit strong anti-tumour responses.

  2. Tumours and tumour-like conditions of the jaw seen in Zaria, Nigeria ...

    African Journals Online (AJOL)

    %) ameloblastomas; 33 (23.4%) fibrous dysplasia; 31 (22.0%) cemento-osseous dysplasia; 9 (6.4%) myxomas; 8 (5.7%) ameloblastic fibroma; and 3 (2.1%) adenomatoid odontogenic tumours; and 9 (6.4%) unclassified tumours. The benign ...

  3. Primary bone tumours of the hand

    International Nuclear Information System (INIS)

    Kozlowski, K.; Azouz, E.M.; Campbell, J.; Marton, D.; Morris, L.; Padovani, J.; Sprague, P.; Beluffi, G.; Berzero, G.F.; Cherubino, P.; Adelaide Children's Hospital; Hospital for Children, Perth; Montreal Children's Hospital, Quebec; Saint Justine Hospital, Montreal, Quebec; Children's Hospital, Denver, CO; Hopital des Enfants, 13 - Marseille; Pavia Univ.; Pavia Univ.

    1988-01-01

    Twenty-one primary bone tumours of the hand in children from 8 paediatric hospitals are reported. Osteochondromas and enchondromas were not included. Our material consisted of 16 patients with common tumours (3 Ewing's sarcoma, 5 aneurysmal bone cyst, 6 osteoid osteoma and 2 epithelioma) and 5 patients with uncommon tumours (osteoma, simple bone cyst, haemangiopericytoma, capillary angiomatous tumour and benign ossifying fibroma or osteoblastoma). The X-ray diagnosis of the common tumours should have high concordance with histology, whereas that of uncommon tumours in much more difficult and uncertain. The characteristic features of Ewing's sarcoma are stressed as all our children with this tumour had a delayed diagnosis and a fatal outcome. Differential diagnosis with other short tubular bone lesions of the hand - specifically osteomyelitis - is discussed and the posibilities of microscopic diagnosis are stressed. (orig.)

  4. Infiltration of peritumoural but tumour-free parenchyma with IgG4-positive plasma cells in hilar cholangiocarcinoma and pancreatic adenocarcinoma.

    Science.gov (United States)

    Resheq, Yazid J; Quaas, Alexander; von Renteln, Daniel; Schramm, Christoph; Lohse, Ansgar W; Lüth, Stefan

    2013-10-01

    Recently, new guidelines for diagnosing IgG4-associated cholangitis have been published devaluing the diagnostic significance of IgG4-positive plasma cells and steroid trials. We sought to evaluate the utility of IgG4-positive plasma cells in discriminating IgG4-associated cholangitis from hilar cholangiocarcinoma and autoimmune pancreatitis from pancreatic adenocarcinoma under conditions when malignancy is likely to be missed. Resection specimens obtained from patients with hilar cholangiocarcinoma, pancreatic adenocarcinoma or hepatocellular carcinoma were re-evaluated for IgG4-positivity. Histological analysis focussed on peritumoural but tumour-free sections. Perioperative biochemical and clinical data were reviewed. Nineteen patients with hilar cholangiocarcinoma and 29 patients with pancreatic adenocarcinoma were eligible for histological re-evaluation. Six of 19 (32%) patients with hilar cholangiocarcinoma and 5 of 29 (17%) patients with pancreatic adenocarcinoma were IgG4-positive (≥20 IgG4-positive plasma cells per high power field). Patients with IgG4-positive hilar cholangiocarcinoma showed significantly higher levels of serum total bilirubin (3.6mg/dl vs. 1.8mg/dl; Philar cholangiocarcinoma. IgG4-positive plasma cells are of limited utility especially in distinguishing hilar cholangiocarcinoma from IgG4-associated cholangitis even when combined with clinical parameters and may be misleading under conditions when malignancy is missed. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Prefraction displacement and intrafraction drift of the prostate due to perineal ultrasound probe pressure

    Energy Technology Data Exchange (ETDEWEB)

    Li, Minglun; Hegemann, Nina-Sophie; Manapov, Farkhad; Kolberg, Anne; Thum, Patrick Dominik; Ganswindt, Ute; Belka, Claus [LMU Munich, Department of Radiation Oncology, Munich (Germany); Ballhausen, Hendrik [LMU Munich, Department of Radiation Oncology, Munich (Germany); University Hospital of LMU Munich, Munich (Germany)

    2017-06-15

    In image-guided EBRT of the prostate, transperineal ultrasound (US) probes exert pressure on the perineum both during planning and treatment. Through tissue deformation and relaxation, this causes target and risk organ displacement and drift. In this study, prefraction shift and intrafraction drift of the prostate are quantified during robotic transperineal 4DUS. The position of the prostate was recorded for different positions of the probe before treatment in 10 patients (16 series of measurements). During treatment (15 patients, 273 fractions), intrafraction motion of the prostate was tracked (total of 27 h and 24 min) with the transperineal probe in place. Per 1 mm shift of the US probe in the cranial direction, a displacement of the prostate by 0.42 ± 0.09 mm in the cranial direction was detected. The relationship was found to be linear (R{sup 2} = 0.97) and highly significant (p < 0.0001). After initial contact of the probe and the perineum (no pressure), a shift of the probe of about 5-10 mm was typically necessary to achieve good image quality, corresponding to a shift of the prostate of about 2-4 mm in the cranial direction. Tissue compression and prostate displacement were well visible. During treatment, the prostate drifted at an average rate of 0.075 mm/min in the cranial direction (p = 0.0014). The pressure applied by a perineal US probe has a quantitatively similar impact on prostate displacement as transabdominal pressure. Shifts are predominantly in the cranial direction (typically 2-4 mm) with some component in the anterior direction (typically <1 mm). Slight probe pressure can improve image quality, but excessive probe pressure can distort the surrounding anatomy and potentially move risk organs closer to the high-dose area. (orig.) [German] In der bildgefuehrten Strahlentherapie der Prostata ueben perineale Ultraschallkoepfe waehrend Planung und Behandlung Druck auf das Perineum aus. Durch Gewebedeformation verursacht dies Verschiebungen von

  6. Establishing tumour tracking accuracy in free-breathing respiratory gated SBRT of lung cancer

    International Nuclear Information System (INIS)

    Wen, Chuan-Dong; Wong, C; Ackerly, T; Ruben, J; Millar, J

    2014-01-01

    Free-breathing respiratory gated SBRT of surgically inoperable lung cancer has been clinically commissioned. This study was to establish the tumour tracking accuracy under clinical conditions based on an implanted fiducial marker. A Visicoil TM marker embedded in tissue-equivalent material mounted in a phantom (ET Gating Phantom TM Brainlab) driven by a patient's breathing data was treated with the ExacTrac TM system. This one-dimensional moving marker represented a tumour motion in superior-inferior (S-I) direction measured through 4DCT study of the same patient. Both Gafchromic TM films and the stereoscopic kV images were used for tracking the position of the marker. For tumour motion at magnitudes of 10, 20 and 29 mm and treated with corresponding gate widths of 50%, 33% and 20% of free breathing amplitude, the implanted marker was able to be tracked with a deviation ≤1.53 mm to its planned position.

  7. Whole-tumour diffusion kurtosis MR imaging histogram analysis of rectal adenocarcinoma: Correlation with clinical pathologic prognostic factors.

    Science.gov (United States)

    Cui, Yanfen; Yang, Xiaotang; Du, Xiaosong; Zhuo, Zhizheng; Xin, Lei; Cheng, Xintao

    2018-04-01

    To investigate potential relationships between diffusion kurtosis imaging (DKI)-derived parameters using whole-tumour volume histogram analysis and clinicopathological prognostic factors in patients with rectal adenocarcinoma. 79 consecutive patients who underwent MRI examination with rectal adenocarcinoma were retrospectively evaluated. Parameters D, K and conventional ADC were measured using whole-tumour volume histogram analysis. Student's t-test or Mann-Whitney U-test, receiver operating characteristic curves and Spearman's correlation were used for statistical analysis. Almost all the percentile metrics of K were correlated positively with nodal involvement, higher histological grades, the presence of lymphangiovascular invasion (LVI) and circumferential margin (CRM) (phistogram analysis, especially K parameters, were associated with important prognostic factors of rectal cancer. • K correlated positively with some important prognostic factors of rectal cancer. • K mean showed higher AUC and specificity for differentiation of nodal involvement. • DKI metrics with whole-tumour volume histogram analysis depicted tumour heterogeneity.

  8. Comparison of tumour age response to radiation for cells derived from tissue culture or solid tumours

    International Nuclear Information System (INIS)

    Keng, P.C.; Siemann, D.W.; Rochester Univ., NY; Rochester Univ., NY; Wheeler, K.T.

    1984-01-01

    Direct comparison of the cell age response of 9L and KHT tumour cells derived either from tissue culture or solid tumours was achieved. Cells from dissociated KHT and 9L tumours (the latter implanted either subcutaneously or intracerebrally) and cells from tissue culture were separated into homogenous sized populations by centrifugal elutriation. In both tumour models these homogeneous sized populations correspond to populations enriched at different stages of the cell cycle. The survival of these elutriated cell populations was measured after a single dose of Cs-137 gamma rays. For cells isolated from 9L solid tumours, there was little variation in radiosensitivity throughout the cell cycle; however, a very small but significant increase in resistance was found in late G 1 cells. This lack of a large variation in radiosensitivity through the cell cycle for 9L cells from solid tumours also was seen in 9L cells growing in monolayer tissue culture. When similar experiments were performed using the KHT sarcoma tumour model, the results showed that KHT cells in vitro exhibited a fairly conventional increase in radioresistance in both mid G 1 and late S. However, the cell age response of KHT cells from solid tumours was different; particularly in the late S and G 2 + M phases. (author)

  9. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes

    DEFF Research Database (Denmark)

    Bjerre, Troels; Crijns, Sjoerd; Rosenschöld, Per Munck af

    2013-01-01

    The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking...... of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path....... For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm...

  10. MRI characteristics of midbrain tumours

    International Nuclear Information System (INIS)

    Sun, B.; Wang, C.C.; Wang, J.

    1999-01-01

    We diagnosed 60 cases of midbrain tumours by MRI between 1993 to 1997. There were 39 males and 21 females, aged 2-64 years, mean 25.6 years. We found 38 patients with true intramedullary midbrain tumours, 11 predominantly in the tectum, 20 in the tegmentum and 7 with a downward extension to the pons; there were 7 within the cerebral aqueduct. There were 22 patients with infiltrating midbrain tumours extending from adjacent structures, 11 cases each from the thalamus and pineal region. All patients received surgical treatment. Gross total resection was achieved in 42 cases, subtotal (> 75 %) resection in 18. Pathological diagnoses included 16 low-grade and 15 high-grade astrocytomas; 5 oligodendroastrocytomas; 2 ependymomas; 11 glioblastomas; and 11 pineal parenchymal or germ-cell tumours. Midbrain tumours are a heterogeneous group of neoplasms, with wide variation in clinical and MRI features, related to the site and type of tumour. MRI not only allows precise analysis of their growth pattern, but also can lead to a correct preoperative diagnosis in the majority of cases. (orig.) (orig.)

  11. Parameter estimation of breast tumour using dynamic neural network from thermal pattern

    Directory of Open Access Journals (Sweden)

    Elham Saniei

    2016-11-01

    Full Text Available This article presents a new approach for estimating the depth, size, and metabolic heat generation rate of a tumour. For this purpose, the surface temperature distribution of a breast thermal image and the dynamic neural network was used. The research consisted of two steps: forward and inverse. For the forward section, a finite element model was created. The Pennes bio-heat equation was solved to find surface and depth temperature distributions. Data from the analysis, then, were used to train the dynamic neural network model (DNN. Results from the DNN training/testing confirmed those of the finite element model. For the inverse section, the trained neural network was applied to estimate the depth temperature distribution (tumour position from the surface temperature profile, extracted from the thermal image. Finally, tumour parameters were obtained from the depth temperature distribution. Experimental findings (20 patients were promising in terms of the model’s potential for retrieving tumour parameters.

  12. Neurofibromatosis type 1: brain stem tumours

    International Nuclear Information System (INIS)

    Bilaniuk, L.T.; Molloy, P.T.; Zimmerman, R.A.; Phillips, P.C.; Vaughan, S.N.; Liu, G.T.; Sutton, L.N.; Needle, M.

    1997-01-01

    We describe the clinical and imaging findings of brain stem tumours in patients with neurofibromatosis type 1 (NF1). The NF1 patients imaged between January 1984 and January 1996 were reviewed and 25 patients were identified with a brain stem tumour. Clinical, radiographical and pathological results were obtained by review of records and images. Brain stem tumour identification occurred much later than the clinical diagnosis of NF1. Medullary enlargement was most frequent (68 %), followed by pontine (52 %) and midbrain enlargement (44 %). Patients were further subdivided into those with diffuse (12 patients) and those with focal (13 patients) tumours. Treatment for hydrocephalus was required in 67 % of the first group and only 15 % of the second group. Surgery was performed in four patients and revealed fibrillary astrocytomas, one of which progressed to an anaplastic astrocytoma. In 40 % of patients both brain stem and optic pathway tumours were present. The biological behaviour of brain stem tumours in NF1 is unknown. Diffuse tumours in the patients with NF1 appear to have a much more favourable prognosis than patients with similar tumours without neurofibromatosis type 1. (orig.). With 7 figs., 3 tabs

  13. Uncommon presentation of a rare tumour - incidental finding in an asymptomatic patient: case report and comprehensive review of the literature on intrapericardial solitary fibrous tumours.

    Science.gov (United States)

    Czimbalmos, Csilla; Csecs, Ibolya; Polos, Miklos; Bartha, Elektra; Szucs, Nikolette; Toth, Attila; Maurovich-Horvat, Pal; Becker, David; Sapi, Zoltan; Szabolcs, Zoltan; Merkely, Bela; Vago, Hajnalka

    2017-09-02

    A solitary fibrous tumour is a rare, mainly benign spindle cell mesenchymal tumour most commonly originating from the pleura. An intrapericardial location of a solitary fibrous tumour is extremely unusual. We present a case of an asymptomatic patient with a slow-growing massive benign cardiac solitary fibrous tumour. A 37-year-old asymptomatic female patient was referred to our hospital with an enlarged cardiac silhouette found on her screening chest X-ray. The echocardiographic examination revealed pericardial effusion and an inhomogeneous mobile mass located in the pericardial sac around the left ventricle. Cardiac magnetic resonance (MRI) examination showed an intrapericardial, semilunar-shaped mass attached to the pulmonary trunk with an intermediate signal intensity on proton density-weighted images and high signal intensity on T2-weighted spectral fat saturation inversion recovery images. First-pass perfusion and early and late gadolinium-enhanced images showed a vascularized mass with septated, patchy, inhomogeneous late enhancement. Coronary computed tomography angiography revealed no invasion of the coronaries. Based on the retrospectively analysed screening chest X-rays, the mass had started to form at least 7 years earlier. Complete resection of the tumour with partial resection of the pulmonary trunk was performed. Histological evaluation of the septated, cystic mass revealed tumour cells forming an irregular patternless pattern; immunohistochemically, the cells tested positive for vimentin, CD34, CD99 and STAT6 but negative for keratin (AE1-AE3), CD31 and S100. Thus, the diagnosis of an intrapericardial solitary fibrous tumour was established. There has been no recurrence for 3 years based on the regular MRI follow-up. Intrapericardial SFTs, showing slow growth dynamics, can present with massive extent even in completely asymptomatic patients. MRI is exceedingly useful for characterizing intrapericardial masses, allowing precise surgical planning, and

  14. Surgical management of epithelial parotid tumours

    International Nuclear Information System (INIS)

    Obaid, M.A.; Yusuf, A.

    2004-01-01

    Objective: To describe the clinicopathological presentation and treatment options in epithelial parotid tumours with emphasis on surgery. Subjects and Methods: Epithelial parotid tumours diagnosed and operated by an ENT surgeon and a general surgeon in 10 years during their posting in different teaching hospitals were included in the study. Clinical presentation, preoperative investigations, operative procedure, histopathology report, postoperative complications and further management were recorded. The data was collected and reviewed from the records of all the patients maintained by the authors. Results: Fifty-two patients presented with parotid tumour. Average age was 38 years. Commonest presentation was painless lump over the parotid region (85%), pain (15%), facial palsy, and enlarged neck nodes. Majority of tumours were benign, only two were recurrent. Parotid pleomorphic Adenoma (PPA) was the commonest benign tumour, others being Warthin's tumour and monomorphic adenoma. Adenoid cystic carcinoma was the commonest malignant tumour 29% followed by mucoepidermoid carcinoma. Others were carcinoma in PPA squamous cell carcinoma, malignant mixed tumour, malignant Iymphoepithelioma and undifferentiated carcinoma. Superficial parotidectomy (SP) was the commonest operation performed in 69%. Other procedures were total conservative parotidectomy in 11%, total radical surgery in 9% and enucleation in only one patient earliest in the series. Neck node dissection was done in 2 patients. Except for one child, rest of the 13 patients received postoperative radiotherapy and one patient of Iymphoepithelioma received chemotherapy in addition. Commonest postoperative complication was temporary facial weakness in 35% (18/52). Permanent facial palsy occurred in 08 patients. Of these 07 had a malignant process and only one patient had excision biopsy. Conclusion: Benign and malignant epithelial parotid tumours can be diagnosed by there clinical presentation . supplemented with

  15. Cancer and Exercise: Warburg Hypothesis, Tumour Metabolism and High-Intensity Anaerobic Exercise.

    Science.gov (United States)

    Hofmann, Peter

    2018-01-31

    There is ample evidence that regular moderate to vigorous aerobic physical activity is related to a reduced risk for various forms of cancer to suggest a causal relationship. Exercise is associated with positive changes in fitness, body composition, and physical functioning as well as in patient-reported outcomes such as fatigue, sleep quality, or health-related quality of life. Emerging evidence indicates that exercise may also be directly linked to the control of tumour biology through direct effects on tumour-intrinsic factors. Beside a multitude of effects of exercise on the human body, one underscored effect of exercise training is to target the specific metabolism of tumour cells, namely the Warburg-type highly glycolytic metabolism. Tumour metabolism as well as the tumour⁻host interaction may be selectively influenced by single bouts as well as regularly applied exercise, dependent on exercise intensity, duration, frequency and mode. High-intensity anaerobic exercise was shown to inhibit glycolysis and some studies in animals showed that effects on tumour growth might be stronger compared with moderate-intensity aerobic exercise. High-intensity exercise was shown to be safe in patients; however, it has to be applied carefully with an individualized prescription of exercise.

  16. A forgotten facial nerve tumour: granular cell tumour of the parotid and its implications for treatment.

    Science.gov (United States)

    Lerut, B; Vosbeck, J; Linder, T E

    2011-04-01

    We present a rare case of a facial nerve granular cell tumour in the right parotid gland, in a 10-year-old boy. A parotid or neurogenic tumour was suspected, based on magnetic resonance imaging. Intra-operatively, strong adhesions to surrounding structures were found, and a midfacial nerve branch had to be sacrificed for complete tumour removal. Recent reports verify that granular cell tumours arise from Schwann cells of peripheral nerve branches. The rarity of this tumour within the parotid gland, its origin from peripheral nerves, its sometimes misleading imaging characteristics, and its rare presentation with facial weakness and pain all have considerable implications on the surgical strategy and pre-operative counselling. Fine needle aspiration cytology may confirm the neurogenic origin of this lesion. When resecting the tumour, the surgeon must anticipate strong adherence to the facial nerve and be prepared to graft, or sacrifice, certain branches of this nerve.

  17. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  18. VIP secreting tumours in infancy

    International Nuclear Information System (INIS)

    Davies, R.P.; Slavotinek, J.P.; Dorney, S.F.A.

    1990-01-01

    Vasoactive intestinal polypeptide (VIP) secreting neural crest tumours are an uncommon but important treatable cause of intractable childhood diarrhoea. The radiological appearances of two cases are presented with a review of radiological findings in childhood VIP secreting neural crest tumours. Twenty eight cases of childhood VIP secreting neural crest tumours were reviewed. Nineteen (68%) were ganglioneuroblastomas and nine (32%) were ganglioneuromas. The majority of tumours (66%) were in a paravertebral location in the abdomen indicating that a search for such a tumour should be initiated at this site. Eighteen of the twenty eight cases reviewed discussed relevant radiological investigations. Calcification was detected in 50% of abdominal radiographs. Gut dilatation was often a prominent feature. A mass was detected in 5 of 5 cases where ultrasound findings were reported, and seven of seven cases with CT findings reported. Prior to the availability of CT and ultrasound the most useful investigation was IVU which demonstrated evidence of a mass in 5 of 9 cases. The presence of paravertebral calcification and gut dilatation on the plain radiograph of a child with intractable diarrhoea suggests the presence of a VIP secreting neural crest tumour. If an abdominal tumour is not found in the appropriate clinical setting and VIP levels are elevated, a widespread search of the paravertebral region is indicated. (orig.)

  19. A rare benign renal tumour presenting as polycythaemia in a teenage girl.

    LENUS (Irish Health Repository)

    Geoghegan, S

    2010-04-01

    We present the case of a 15-year-old girl who presented with polycythemia. CT abdomen revealed an enhancing mass in the upper pole of her left kidney with features suggestive of renal cell carcinoma. She underwent a laparoscopic radical nephrectomy. Histology demonstrated a well circumscribed, focally encapsulated, round blue cell tumour showing areas of microcalcifications and numerous psammoma bodies. Imunostaining showed diffuse positive staining for CD 57. This was consistent with a diagnosis of metanephric adenoma a rare benign epithelial renal tumour.

  20. DOTA-PESIN, a DOTA-conjugated bombesin derivative designed for the imaging and targeted radionuclide treatment of bombesin receptor-positive tumours

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hanwen; Maecke, Helmut R. [University Hospital Basel, Division of Radiological Chemistry, Department of Radiology, Basel (Switzerland); Schuhmacher, Jochen; Eisenhut, Michael [German Cancer Research Centre, Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Waser, Beatrice; Reubi, Jean Claude [University of Berne, Division of Cell Biology and Experimental Cancer Research, Institute of Pathology, P.O. Box 62, Berne (Switzerland); Wild, Damian [University Hospital, Clinic and Institute of Nuclear Medicine, Department of Radiology, Basel (Switzerland)

    2007-08-15

    We aimed at designing and developing a novel bombesin analogue, DOTA-PEG{sub 4}-BN(7-14) (DOTA-PESIN), with the goal of labelling it with {sup 67/68}Ga and {sup 177}Lu for diagnosis and radionuclide therapy of prostate and other human cancers overexpressing bombesin receptors. The 8-amino acid peptide bombesin (7-14) was coupled to the macrocyclic chelator DOTA via the spacer 15-amino-4,7,10,13-tetraoxapentadecanoic acid (PEG{sub 4}). The conjugate was complexed with Ga(III) and Lu(III) salts. The GRP receptor affinity and the bombesin receptor subtype profile were determined in human tumour specimens expressing the three bombesin receptor subtypes. Internalisation and efflux studies were performed with the human GRP receptor cell line PC-3. Xenografted nude mice were used for biodistribution. [Ga{sup III}/Lu{sup III}]-DOTA-PESIN showed good affinity to GRP and neuromedin B receptors but no affinity to BB3. [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN internalised rapidly into PC-3 cells whereas the efflux from PC-3 cells was relatively slow. In vivo experiments showed a high and specific tumour uptake and good retention of [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN. [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN highly accumulated in GRP receptor-expressing mouse pancreas. The uptake specificity was demonstrated by blocking tumour uptake and pancreas uptake. Fast clearance was found from blood and all non-target organs except the kidneys. High tumour-to-normal tissue ratios were achieved, which increased with time. PET imaging with [{sup 68}Ga]-DOTA-PESIN was successful in visualising the tumour at 1 h post injection. Planar scintigraphic imaging showed that the {sup 177}Lu-labelled peptide remained in the tumour even 3 days post injection. The newly designed ligands have high potential with regard to PET and SPECT imaging with {sup 68/67}Ga and targeted radionuclide therapy with {sup 177}Lu. (orig.)

  1. Targeting radiation to tumours

    International Nuclear Information System (INIS)

    Wheldon, T.E.; Greater Glasgow Health Board, Glasgow

    1994-01-01

    Biologically targeted radiotherapy entails the preferential delivery of radiation to solid tumours or individual tumour cells by means of tumour-seeking delivery vehicles to which radionuclides can be conjugated. Monoclonal antibodies have attracted attention for some years as potentially selective targeting agents, but advances in tumour and molecular biology are now providing a much wider choice of molecular species. General radiobiological principles may be derived which are applicable to most forms of targeted radiotherapy. These principles provide guidelines for the appropriate choice of radionuclide in specific treatment situations and its optimal combination with other treatment modalities. In future, the availability of gene targeting agents will focus attention on the use of Auger electron emitters whose high potency and short range selectivity makes them attractive choices for specific killing of cancer cells whose genetic peculiarities are known. (author)

  2. SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

    Energy Technology Data Exchange (ETDEWEB)

    Menten, MJ; Fast, MF; Nill, S; Oelfke, U [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2016-06-15

    Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin: 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical

  3. Neutrophil-induced transmigration of tumour cells treated with tumour-conditioned medium is facilitated by granulocyte-macrophage colony-stimulating factor.

    LENUS (Irish Health Repository)

    Wu, Q D

    2012-02-03

    OBJECTIVE: To investigate the effect of different cytokines that are present in tumour-conditioned medium on human neutrophil (PMN)-induced tumour cell transmigration. DESIGN: Laboratory study. SETTING: University hospital, Ireland. MATERIAL: Isolated human PMN and cultured human breast tumour cell line, MDA-MB-231. Interventions: Human PMN treated with either tumour-conditioned medium or different media neutralised with monoclonal antibodies (MoAb), and MDA-MB-231 cells were plated on macrovascular and microvascular endothelial monolayers in collagen-coated transwells to assess migration of tumour cells. MAIN OUTCOME MEASURES: Cytokines present in tumour-conditioned medium, PMN cytocidal function and receptor expression, and tumour cell transmigration. RESULTS: tumour-conditioned medium contained high concentrations of granulocyte-macrophage colony-stimulating factor (GM-CSF), vascular endothelial growth factor (VEGF), and interleukin 8 (IL-8), but not granulocyte colony-stimulating factor (G-CSF) and interleukin 3 (IL-3). Anti-GM-CSF MoAb significantly reduced PMN-induced transmigration of tumour cells treated with tumour-conditioned medium (p < 0.05), whereas anti-VEGF and anti-IL-8 MoAbs did not affect their migration. In addition, anti-GM-CSF MoAb, but not anti-VEGF or anti-IL-8 MoAb, reduced PMN CD11b and CD18 overexpression induced by tumour-conditioned medium (p < 0.05). CONCLUSION: These results indicate that the GM-CSF that is present in tumour-conditioned medium may be involved, at least in part, in alterations in PMN function mediated by the medium and subsequently PMN-induced transmigration of tumour cells.

  4. The retinoblastoma gene is frequently altered leading to loss of expression in primary breast tumours.

    Science.gov (United States)

    Varley, J M; Armour, J; Swallow, J E; Jeffreys, A J; Ponder, B A; T'Ang, A; Fung, Y K; Brammar, W J; Walker, R A

    1989-06-01

    We have analysed the organisation of the retinoblastoma (RB1) gene in 77 primary breast carcinomas, in metastatic tissue derived from 16 of those primary tumours, and in a variety of benign breast lesions. Expression of RB1 was also assessed in most samples by immunohistochemical detection of the RB1 protein in tissue sections. Structural abnormalities to RB1 were detected in DNA from 15/77 (19%) of primary breast carcinomas examined. Where DNA was available from metastatic tissue derived from such primary tumours, the same aberration could be detected. No alterations were seen in benign breast lesions. 16/56 (29%) of tumours examined for expression by immunohistochemical methods showed a proportion of tumour cells to be completely negative for the RB1 protein. All tumours in which a structural alteration to RB1 was detected had a proportion of negative cells, except for one case where all cells were positive. Several primary tumour samples were identified where there was no detectable structural change to the gene, but there was loss of expression in some tumour cells. The data presented here demonstrate that changes to the RB1 gene leading to loss of expression of both alleles are frequent in primary human breast tumours.

  5. Anti-tumour immune effect of oral administration of Lactobacillus plantarum to CT26 tumour-bearing mice.

    Science.gov (United States)

    Hu, Jingtao; Wang, Chunfeng; Ye, Liping; Yang, Wentao; Huang, Haibin; Meng, Fei; Shi, Shaohua; Ding, Zhuang

    2015-06-01

    Colorectal cancer (CRC) is one of the most prevalent forms of cancer that shows a high mortality and increasing incidence. There are numerous successful treatment options for CRC, including surgery, chemotherapy, radiotherapy and immunotherapy; however, their side effects and limitations are considerable. Probiotics may be an effective strategy for preventing and inhibiting tumour growth through stimulation of host innate and adaptive immunity. We investigated and compared potential anti-tumour immune responses induced by two isolated Lactobacillus strains, Lactobacillus plantarum A and Lactobacillus rhamnosus b, by pre-inoculating mice with lactobacilli for 14 days. Subsequently, subcutaneous and orthotopic intestinal tumours were generated in the pre-inoculated mice using CT26 murine adenocarcinoma cells and were assessed for response against the tumour. Our results indicated that oral administration with L. plantarum inhibited CT26 cell growth in BALB/c mice and prolonged the survival time of tumour-bearing mice compared with mice administered L. rhamnosus. L. plantarum produced protective immunity against the challenge with CT26 cells by increasing the effector functions of CD8+ and natural killer (NK) cell infiltration into tumour tissue, up-regulation of IFN-gamma (but not IL-4 or IL-17) production, and promotion of Th1-type CD4+ T differentiation. Consequently, our results suggest that L. plantarum can enhance the anti-tumour immune response and delay tumour formation.

  6. EpCAM as multi-tumour target for near-infrared fluorescence guided surgery

    International Nuclear Information System (INIS)

    Driel, P. B. A. A. van; Boonstra, M. C.; Prevoo, H. A. J. M.; Giessen, M. van de; Snoeks, T. J. A.; Tummers, Q. R. J. G.; Keereweer, S.; Cordfunke, R. A.; Fish, A.; Eendenburg, J. D. H. van; Lelieveldt, B. P. F.; Dijkstra, J.; Velde, C. J. H. van de; Kuppen, P. J. K.; Vahrmeijer, A. L.; Löwik, C. W. G. M.; Sier, C. F. M.

    2016-01-01

    Evaluation of resection margins during cancer surgery can be challenging, often resulting in incomplete tumour removal. Fluorescence-guided surgery (FGS) aims to aid the surgeon to visualize tumours and resection margins during surgery. FGS relies on a clinically applicable imaging system in combination with a specific tumour-targeting contrast agent. In this study EpCAM (epithelial cell adhesion molecule) is evaluated as target for FGS in combination with the novel Artemis imaging system. The NIR fluorophore IRDye800CW was conjugated to the well-established EpCAM specific monoclonal antibody 323/A3 and an isotype IgG1 as control. The anti-EpCAM/800CW conjugate was stable in serum and showed preserved binding capacity as evaluated on EpCAM positive and negative cell lines, using flow cytometry and cell-based plate assays. Four clinically relevant orthotopic tumour models, i.e. colorectal cancer, breast cancer, head and neck cancer, and peritonitis carcinomatosa, were used to evaluate the performance of the anti-EpCAM agent with the clinically validated Artemis imaging system. The Pearl Impulse small animal imaging system was used as reference. The specificity of the NIRF signal was confirmed using bioluminescence imaging and green-fluorescent protein. All tumour types could clearly be delineated and resected 72 h after injection of the imaging agent. Using NIRF imaging millimetre sized tumour nodules were detected that were invisible for the naked eye. Fluorescence microscopy demonstrated the distribution and tumour specificity of the anti-EpCAM agent. This study shows the potential of an EpCAM specific NIR-fluorescent agent in combination with a clinically validated intraoperative imaging system to visualize various tumours during surgery

  7. Systematic errors in respiratory gating due to intrafraction deformations of the liver

    International Nuclear Information System (INIS)

    Siebenthal, Martin von; Szekely, Gabor; Lomax, Antony J.; Cattin, Philippe C.

    2007-01-01

    This article shows the limitations of respiratory gating due to intrafraction deformations of the right liver lobe. The variability of organ shape and motion over tens of minutes was taken into account for this evaluation, which closes the gap between short-term analysis of a few regular cycles, as it is possible with 4DCT, and long-term analysis of interfraction motion. Time resolved MR volumes (4D MR sequences) were reconstructed for 12 volunteers and subsequent non-rigid registration provided estimates of the 3D trajectories of points within the liver over time. The full motion during free breathing and its distribution over the liver were quantified and respiratory gating was simulated to determine the gating accuracy for different gating signals, duty cycles, and different intervals between patient setup and treatment. Gating effectively compensated for the respiratory motion within short sequences (3 min), but deformations, mainly in the anterior inferior part (Couinaud segments IVb and V), led to systematic deviations from the setup position of more than 5 mm in 7 of 12 subjects after 20 min. We conclude that measurements over a few breathing cycles should not be used as a proof of accurate reproducibility of motion, not even within the same fraction, if it is longer than a few minutes. Although the diaphragm shows the largest magnitude of motion, it should not be used to assess the gating accuracy over the entire liver because the reproducibility is typically much more limited in inferior parts. Simple gating signals, such as the trajectory of skin motion, can detect the exhalation phase, but do not allow for an absolute localization of the complete liver over longer periods because the drift of these signals does not necessarily correlate with the internal drift

  8. 131I-MIBG and neuroendocrine tumours

    International Nuclear Information System (INIS)

    Oliva Gonzalez, Juan Perfecto; Gonzalez Gonzalez, Joaquin Jorge; Calderon Marin, Carlos Fabian

    2012-01-01

    Neuroendocrine tumours are neoplasms that arise from various tissues closely linked to the neural crest by their common embryological origin. These tumours have the ability to synthesize neurotransmitter peptides and hormones, as well as to store catecholamines. Some of these tumours express somatostatin receptors at their membranes, what have allowed nuclear medicine to be involved in their diagnosis, treatment and monitoring. Since they arise from different and varied types of tissues, these tumours have a wide range of signs and symptoms different for every one of them. These signs and symptoms mainly depend on their biochemical characteristics, given by the substances they secrete, as well as by their location, and consequently, they also depend on the place where the tumour appears, its local infiltration, and potential long-distance metastasis resulting from the tumour). Neuroendocrine tumours are diagnosed by means of nuclear medicine images, which are obtained by using different techniques and radiopharmaceuticals such as 99 mTc dimercaptosuccinic acid (DMSA(V)), 99 mTc-methoxy-isobutyl-isonitrile (MIBI), metaiodobenzylguanidine (MIBG) labelled with 131 I or 123 I ( 131 I-MIBG or 123 I -MIBG), 111 In-labelled octreotide, positron emission tomography, using 68 Ga-labelled somatostatin analogues and carcinoembryonic antigen monoclonal antibodies. Nuclear medicine uses mainly somatostatin analogues labelled with 90 Y or 177 Lu for the treatment of these tumours. This paper is aimed at showing our experience in the use of 131 I-MIBG for the diagnosis and treatment of neuroendocrine tumours.(author)

  9. The influence of elevated levels of platelet-derived endothelial cell growth factor/thymidine phosphorylase on tumourigenicity, tumour growth, and oxygenation

    International Nuclear Information System (INIS)

    Griffiths, L.; Stratford, I.J.

    1998-01-01

    Purpose: Investigation of the effect of platelet-derived endothelial cell growth factor/thymidine phosphorylase (PD-ECGF/TP) on various aspects of tumour growth in a xenograft model, including growth rate, tumourigenicity and oxygenation levels. Methods and Materials: MDA 231 breast cancer cells overexpressing PD-ECGF/TP protein were made by retroviral transduction. These cells were grown in vitro and in vivo as xenografts. Direct measurement of tumours was used to record growth parameters, while the comet assay with the bioreductive drug RSU 1069 was used to assess tumour cell oxygenation. Results: We report that MDA 231 breast tumour cell lines expressing an increased range of levels of PD-ECGF/TP have increased tumourigenicity positively related to the level of PD-ECGF/TP when implanted in nude mice. As previously reported, tumours grown from these overexpressing cell lines grew faster than the parental line. These tumours expressed higher levels of TP activity and showed increased immunocytochemical staining for PD-ECGF. In addition, the rate of growth was found to be positively related to the level of PD-ECGF/TP expressed by the tumour cells. When the comet assay was used to compare the oxygenation status of cells between the parental and PD-ECGF/TP overexpressing tumours, the latter were found to have a larger proportion of well oxygenated cells. This is consistent with these tumours having an increased and functionally competent vascular supply in response to the expression of PD-ECGF/TP. Conclusion: PD-ECGF/TP appears to be capable of influencing tumourigenicity, angiogenesis and tumour growth in a proportional manner and can directly influence tumour oxygenation levels via its role in formation of functional vasculature

  10. Tissue feature-based intra-fractional motion tracking for stereoscopic x-ray image guided radiotherapy

    Science.gov (United States)

    Xie, Yaoqin; Xing, Lei; Gu, Jia; Liu, Wu

    2013-06-01

    Real-time knowledge of tumor position during radiation therapy is essential to overcome the adverse effect of intra-fractional organ motion. The goal of this work is to develop a tumor tracking strategy by effectively utilizing the inherent image features of stereoscopic x-ray images acquired during dose delivery. In stereoscopic x-ray image guided radiation delivery, two orthogonal x-ray images are acquired either simultaneously or sequentially. The essence of markerless tumor tracking is the reliable identification of inherent points with distinct tissue features on each projection image and their association between two images. The identification of the feature points on a planar x-ray image is realized by searching for points with high intensity gradient. The feature points are associated by using the scale invariance features transform descriptor. The performance of the proposed technique is evaluated by using images of a motion phantom and four archived clinical cases acquired using either a CyberKnife equipped with a stereoscopic x-ray imaging system, or a LINAC equipped with an onboard kV imager and an electronic portal imaging device. In the phantom study, the results obtained using the proposed method agree with the measurements to within 2 mm in all three directions. In the clinical study, the mean error is 0.48 ± 0.46 mm for four patient data with 144 sequential images. In this work, a tissue feature-based tracking method for stereoscopic x-ray image guided radiation therapy is developed. The technique avoids the invasive procedure of fiducial implantation and may greatly facilitate the clinical workflow.

  11. Tissue feature-based intra-fractional motion tracking for stereoscopic x-ray image guided radiotherapy

    International Nuclear Information System (INIS)

    Xie Yaoqin; Gu Jia; Xing Lei; Liu Wu

    2013-01-01

    Real-time knowledge of tumor position during radiation therapy is essential to overcome the adverse effect of intra-fractional organ motion. The goal of this work is to develop a tumor tracking strategy by effectively utilizing the inherent image features of stereoscopic x-ray images acquired during dose delivery. In stereoscopic x-ray image guided radiation delivery, two orthogonal x-ray images are acquired either simultaneously or sequentially. The essence of markerless tumor tracking is the reliable identification of inherent points with distinct tissue features on each projection image and their association between two images. The identification of the feature points on a planar x-ray image is realized by searching for points with high intensity gradient. The feature points are associated by using the scale invariance features transform descriptor. The performance of the proposed technique is evaluated by using images of a motion phantom and four archived clinical cases acquired using either a CyberKnife equipped with a stereoscopic x-ray imaging system, or a LINAC equipped with an onboard kV imager and an electronic portal imaging device. In the phantom study, the results obtained using the proposed method agree with the measurements to within 2 mm in all three directions. In the clinical study, the mean error is 0.48 ± 0.46 mm for four patient data with 144 sequential images. In this work, a tissue feature-based tracking method for stereoscopic x-ray image guided radiation therapy is developed. The technique avoids the invasive procedure of fiducial implantation and may greatly facilitate the clinical workflow. (paper)

  12. Tocopherol in irradiation of temporary hypoxic tumours

    International Nuclear Information System (INIS)

    Kaagerud, A.; Lund, N.; Peterson, H.I.

    1981-01-01

    The influence of tocopherol on the effect of local irradiation under induced ischaemia by temporary tourniquet of two rat tumours transplanted intramuscularly into one hindleg was evaluated. An impaired retardation of growth rate occurred in tumours irradiated under ischaemia. This effect was eliminated by pretreatment of animals with tocopherol. In separate experiments the method of inducing ischaemia was investigated by MDO-electrode measurements of tumour tissue oxygen pressure. A significant tumour hypoxia was found under tourniquet of the tumour-bearing leg of the animals. Pretreatment with tocopherol did not influence the tumour pO 2 . (Auth.)

  13. IDH1-associated primary glioblastoma in young adults displays differential patterns of tumour and vascular morphology.

    Directory of Open Access Journals (Sweden)

    Sergey Popov

    Full Text Available Glioblastoma is a highly aggressive tumour with marked heterogeneity at the morphological level in both the tumour cells and the associated highly prominent vasculature. As we begin to develop an increased biological insight into the underlying processes driving the disease, fewer attempts have thus far been made to understand these phenotypic differences. We sought to address this by carefully assessing the morphological characteristics of both the tumour cells and the associated vasculature, relating these observations to the IDH1/MGMT status, with a particular focus on the early onset population of young adults who develop primary glioblastoma. 276 primary glioblastoma specimens were classified into their predominant cell morphological type (fibrillary, gemistocytic, giant cell, small cell, oligodendroglial, sarcomatous, and assessed for specific tumour (cellularity, necrosis, palisades and vascular features (glomeruloid structures, arcades, pericyte proliferation. IDH1 positive glioblastomas were associated with a younger age at diagnosis, better clinical outcome, prominent oligodendroglial and small cell tumour cell morphology, pallisading necrosis and glomeruloid vascular proliferation in the absence of arcade-like structures. These features widen the phenotype of IDH1 mutation-positive primary glioblastoma in young adults and provide correlative evidence for a functional role of mutant IDH1 in the differential nature of neo-angiogenesis in different subtypes of glioblastoma.

  14. Subdural enhancement on postoperative spinal MRI after resection of posterior cranial fossa tumours

    Energy Technology Data Exchange (ETDEWEB)

    Warmuth-Metz, M.; Solymosi, L. [Abteilung fuer Neuroradiologie, Klinikum der Bayerischen Julius Maximilians Universitaet, Josef-Schneider-Strasse 11, 97080, Wuerzburg (Germany); Kuehl, J. [Paediatric Oncology, Klinikum der Bayerischen Julius Maximilians Universitaet, Josef-Schneider-Strasse 11, 97080, Wuerzburg (Germany); Krauss, J. [Paediatric Neurosurgery, Klinikum der Bayerischen Julius Maximilians Universitaet, Josef-Schneider-Strasse 11, 97080, Wuerzburg (Germany)

    2004-03-01

    In malignant brain tumours which may disseminate staging, usually by cranial and spinal MRI is necessary. If MRI is performed in the postoperative period pitfalls should be considered. Nonspecific subdural contrast enhancement on spinal staging MRI is rarely reported after resection of posterior fossa tumours, which may be mistaken for dissemination of malignancy. We investigated the frequency of spinal subdural enhancement after posterior cranial fossa neurosurgery in children. We reviewed 53 postoperative spinal MRI studies performed for staging of paediatric malignant brain tumours, mainly infratentorial primitive neuroectodermal tumours 2-40 days after surgery. There was contrast enhancement in the spinal subdural space in seven cases. This was not seen in any of eight patients who had been operated upon for a supratentorial tumour. After resection of 45 posterior cranial fossa tumours the frequency of subdural enhancement was 15.5%. MRI showing subdural enhancement was obtained up to 25 days postoperatively. No patient with subdural enhancement had cerebrospinal fluid (CSF) examinations positive for tumour cells or developed dissemination of disease in the CSF. Because the characteristic appearances of subdural contrast enhancement, appropriate interpretation is possible; diagnosis of neoplastic meningitis should rarely be impeded. Because of the striking similarity to that in patients with a low CSF-pressure syndrome and in view of the fact that only resection of tumours of the posterior cranial fossa, usually associated with obstructive hydrocephalus, was followed by this type of enhancement one might suggest that rapid changes in CSF pressure are implicated, rather the effects of blood introduced into the spinal canal at surgery. (orig.)

  15. Subdural enhancement on postoperative spinal MRI after resection of posterior cranial fossa tumours

    International Nuclear Information System (INIS)

    Warmuth-Metz, M.; Solymosi, L.; Kuehl, J.; Krauss, J.

    2004-01-01

    In malignant brain tumours which may disseminate staging, usually by cranial and spinal MRI is necessary. If MRI is performed in the postoperative period pitfalls should be considered. Nonspecific subdural contrast enhancement on spinal staging MRI is rarely reported after resection of posterior fossa tumours, which may be mistaken for dissemination of malignancy. We investigated the frequency of spinal subdural enhancement after posterior cranial fossa neurosurgery in children. We reviewed 53 postoperative spinal MRI studies performed for staging of paediatric malignant brain tumours, mainly infratentorial primitive neuroectodermal tumours 2-40 days after surgery. There was contrast enhancement in the spinal subdural space in seven cases. This was not seen in any of eight patients who had been operated upon for a supratentorial tumour. After resection of 45 posterior cranial fossa tumours the frequency of subdural enhancement was 15.5%. MRI showing subdural enhancement was obtained up to 25 days postoperatively. No patient with subdural enhancement had cerebrospinal fluid (CSF) examinations positive for tumour cells or developed dissemination of disease in the CSF. Because the characteristic appearances of subdural contrast enhancement, appropriate interpretation is possible; diagnosis of neoplastic meningitis should rarely be impeded. Because of the striking similarity to that in patients with a low CSF-pressure syndrome and in view of the fact that only resection of tumours of the posterior cranial fossa, usually associated with obstructive hydrocephalus, was followed by this type of enhancement one might suggest that rapid changes in CSF pressure are implicated, rather the effects of blood introduced into the spinal canal at surgery. (orig.)

  16. Primary pleuro-pulmonary malignant germ cell tumours.

    Directory of Open Access Journals (Sweden)

    Vaideeswar P

    2002-01-01

    Full Text Available Lungs and pleura are rare sites for malignant germ-cell tumours. Two cases, pure yolk-sac tumour and yolk sac-sac tumour/embryonal carcinoma are described in young males who presented with rapid progression of respiratory symptoms. The malignant mixed germ cell tumour occurred in the right lung, while the yolk-sac tumour had a pseudomesotheliomatous growth pattern suggesting a pleural origin. Alpha-foetoprotein was immunohistochemically demonstrated in both.

  17. Chemokine receptor expression in tumour islets and stroma in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ohri, Chandra M; Shikotra, Aarti; Green, Ruth H; Waller, David A; Bradding, Peter

    2010-01-01

    We have previously demonstrated that tumour islet infiltration by macrophages is associated with extended survival (ES) in NSCLC. We therefore hypothesised that patients with improved survival would have high tumour islet expression of chemokine receptors known to be associated with favourable prognosis in cancer. This study investigated chemokine receptor expression in the tumour islets and stroma in NSCLC. We used immunohistochemistry to identify cells expressing CXCR1, CXCR2, CXCR3, CXCR4, CXCR5 and CCR1 in the tumour islets and stroma in 20 patients with surgically resected NSCLC. Correlations were made with macrophage and mast cell expression. There was increased expression of CXCR2, CXCR3, and CCR1 in the tumour islets of ES compared with poor survival (PS) patients (p = 0.007, 0.01, and 0.002, respectively). There was an association between 5 year survival and tumour islet CXCR2, CXCR3 and CCR1 density (p = 0.02, 0.003 and <0.001, respectively) as well as stromal CXCR3 density (p = 0.003). There was a positive correlation between macrophage density and CXCR3 expression (r s = 0.520, p = 0.02) and between mast cell density and CXCR3 expression (r s = 0.499, p = 0.03) in the tumour islets. Above median expression of CXCR2, CXCR3 and CCR1 in the tumour islets is associated with increased survival in NSCLC, and expression of CXCR3 correlates with increased macrophage and mast cell infiltration in the tumour islets

  18. MRI of primary meningeal tumours in children

    International Nuclear Information System (INIS)

    Yoon, H.K.; Na, D.G.; Byun, H.S.; Han, B.K.; Kim, S.S.; Kim, I.O.; Shin, H.J.

    1999-01-01

    Childhood meningeal tumours are uncommon and mostly meningiomas. We reviewed the histological and radiological findings in meningeal tumours in six children aged 12 years or less (four benign meningiomas, one malignant meningioma and one haemangiopericytoma). Compared to the adult counterpart, childhood meningiomas showed atypical features: cysts, haemorrhage, aggressiveness and unusual location. MRI features varied according to the site of the tumour, histology, haemorrhage, and presence of intra- or peritumoral cysts. Diagnosis of the extra-axial tumour was relatively easy in two patients with meningiomas, one malignant meningioma and one haemangiopericytoma. MRI findings strongly suggested an intra-axial tumour in two patients with benign meningiomas, because of severe adjacent edema. Awareness of the variable findings of childhood meningiomas and similar tumours may help in differentiation from brain tumours. (orig.)

  19. Acetyltransferases and tumour suppression

    International Nuclear Information System (INIS)

    Phillips, A C; Vousden, Karen H

    2000-01-01

    The acetyltransferase p300 was first identified associated with the adenoviral transforming protein E1A, suggesting a potential role for p300 in the regulation of cell proliferation. Direct evidence demonstrating a role for p300 in human tumours was lacking until the recentl publication by Gayther et al, which strongly supports a role for p300 as a tumour suppressor. The authors identify truncating mutations associated with the loss or mutation of the second allele in both tumour samples and cell lines, suggesting that loss of p300 may play a role in the development of a subset of human cancers

  20. Displacement of the normal pituitary gland by sellar and juxtasellar tumours: surgical-MRI correlation and use in differential diagnosis

    International Nuclear Information System (INIS)

    Sumida, M.; Uozumi, T.; Yamanaka, M.; Mukada, K.; Arita, K.; Kurisu, K.; Satoh, H.; Ikawa, F.

    1994-01-01

    We compared the position of the normal pituitary gland as estimated by gadolinium (Gd)-DTPA-enhanced MRI, with its position at surgery in 40 patients with intra- and juxtasellar tumours: 22 pituitary adenomas, 4 craniopharyngiomas, 7 meningiomas, 2 germinomas, and 5 Rathke cleft cysts. In 37 of these, the normal gland showed more intense contrast enhancement than the adjacent tumour, from which it could be differentiated by Gd-DTPA-enhanced MRI, especially in the sagittal plane. The direction of displacement of the normal pituitary gland correlated well with tumour type, so that its position proved helpful in the differential diagnosis. The normal gland was typically displaced superiorly by pituitary adenomas, inferiorly by craniopharyngiomas, and anteriorly by germinomas. It showed variable displacement by Rathke cleft cysts, and was not usually displaced by meningiomas. (orig.)

  1. Musculoskeletal desmoid tumours: Diagnostic imaging appearances

    International Nuclear Information System (INIS)

    Liu, Daniel; Perera, Warren; Schlicht, Stephen; Choong, Peter; Slavin, John; Pianta, Marcus

    2015-01-01

    This study aimed to discuss the role medical imaging has on diagnosis of musculoskeletal desmoid tumours and to describe their radiological appearances on various imaging modalities. Imaging of histologically proven cases of desmoid tumours at St. Vincent's Hospital Melbourne were obtained via picture archiving communication system (PACS) and then assessed by two musculoskeletal radiologists. Suitable imagings were obtained from PACS. All imaging chosen was de-identified. Desmoid tumours can occur in many areas of the body. Imaging plays an important role in the diagnosis of these tumours and magnetic resonance imaging has been the gold standard for imaging and is the most accurate in terms of assessing tumour margins and involvement of surrounding structure.

  2. Pitfalls in colour photography of choroidal tumours

    Science.gov (United States)

    Schalenbourg, A; Zografos, L

    2013-01-01

    Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown. PMID:23238442

  3. Pitfalls in colour photography of choroidal tumours.

    Science.gov (United States)

    Schalenbourg, A; Zografos, L

    2013-02-01

    Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown.

  4. Utility of Gallium-68 DOTANOC PET/CT in the localization of Tumour-induced osteomalacia.

    Science.gov (United States)

    Bhavani, Nisha; Reena Asirvatham, Adlyne; Kallur, Kumar; Menon, Arun S; Pavithran, Praveen V; Nair, Vasantha; Vasukutty, Jayakumar R; Menon, Usha; Kumar, Harish

    2016-01-01

    Tumour-induced osteomalacia (TIO) is a rare disorder characterized by hypophosphataemic osteomalacia caused by small mesenchymal tumours secreting fibroblast growth factor 23 (FGF 23). The most difficult part in the management of these patients is the localization of tumours causing TIO. We describe the utility of Gallium (Ga)-68 DOTANOC PET/CT in the localization of tumours causing TIO. The study was conducted in a single tertiary referral university teaching hospital in India. Ten patients with TIO who underwent Ga-68 DOTANOC PET/CT from the time period 2009 to 2014 were included in this study. Their detailed clinical history, biochemical parameters, imaging modalities, surgical interventions, histopathology and outcomes were reviewed. Ga-68 DOTANOC PET/CT could correctly localize the tumours in TIO in 9 of the 10 cases in which it was performed. Complete resection of the tumour led to full clinical recovery in six of the ten patients; two patients who had partial resection and one patient who underwent radiofrequency ablation showed partial remission. One patient in whom Ga-68 DOTANOC PET/CT was positive in vertebral body with a low standardized uptake value (SUV) did not show up the tumour on surgery. We conclude that Ga-68 DOTANOC PET/CT can be used as the first imaging modality in patients diagnosed with TIO. The extremely good outcome following the resection of these small otherwise undiagnosed tumours far outweighs its cost even in resource limited settings. © 2015 John Wiley & Sons Ltd.

  5. Imaging oxygenation of human tumours

    International Nuclear Information System (INIS)

    Padhani, Anwar R.; Krohn, Kenneth A.; Lewis, Jason S.; Alber, Markus

    2007-01-01

    Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and invasive techniques but the inter-relationships between these remains largely undefined. 18 F-MISO and Cu-ATSM-PET, and BOLD-MRI are the lead contenders for human application based on their non-invasive nature, ease of use and robustness, measurement of hypoxia status, validity, ability to demonstrate heterogeneity and general availability, these techniques are the primary focus of this review. We discuss where developments are required for hypoxia imaging to become clinically useful and explore potential new uses for hypoxia imaging techniques including biological conformal radiotherapy. (orig.)

  6. Granular cell tumour of the neurohypophysis: a rare sellar tumour with specific radiological and operative features.

    LENUS (Irish Health Repository)

    Aquilina, K

    2012-02-03

    Symptomatic granular cell tumours of the neurohypophysis are rare sellar lesions. Preoperative prediction of the diagnosis on the basis of radiological appearance is useful as these tumours carry specific surgical difficulties. This is possible when the tumour arises from the pituitary stalk, rostral to a normal pituitary gland. This has not been emphasized previously.

  7. A FIVE-YEAR HISTOPATHOLOGICAL REVIEW OF CNS TUMOURS IN A TERTIARY CENTRE WITH EMPHASIS ON DIAGNOSTIC ASPECTS OF UNCOMMON TUMOURS

    Directory of Open Access Journals (Sweden)

    Premalatha Pidakala

    2016-06-01

    Full Text Available BACKGROUND Tumours of central nervous system (CNS are of varied histogenesis and show divergent lines of differentiation and morphological features. These tumours show specific predilection for age and sex groups, more commonly than of tumours of other systems. Though tumours of glial tissue are more common, other tumours of neural, ependymal and meningeal origin are not uncommon. Metastatic disease is the common encounter in elderly. Tumour diagnosis is not always straight forward as many non-neoplastic lesions and reactive proliferations mimic tumours. Immunohistochemistry may help in problematic cases and thus can be used as an adjuvant tool in the diagnosis of such cases in addition to the routine histopathological staining methods. An accurate histological diagnosis is of extreme importance in these sites as exact diagnosis helps in proper management and favourable clinical outcome. MATERIAL & METHODS This study is on a retrospective and prospective basis in our institution from January 2011 to January, 2016. Our institute is a tertiary care center attached to a medical college catering to the needs of a rural based population. During this period, a total of 717 central nervous system tumour specimens were received and diagnosed based on examination of Haematoxylin and Eosin stained sections of formalin fixed and paraffin embedded specimens. Immunohistochemical markers (IHC were applied in selective cases for an accurate diagnosis and a number of rare cases were diagnosed based on morphology and IHC marker studies. RESULTS Age and sex incidence and anatomic distribution of various tumours were studied. In adults, meningiomas occurred most frequently in the present study followed by nerve sheath tumours, astrocytomas, metastatic deposits, glioblastomas and pituitary adenomas. Embryonal tumours occurred frequently in children. Other rare tumours identified are amyloidogenic pituitary adenoma, central neurocytoma, glioneuronal tumour with

  8. High frequency of albinism and tumours in free-living birds around Chernobyl.

    Science.gov (United States)

    Møller, A P; Bonisoli-Alquati, A; Mousseau, T A

    2013-09-18

    The effects of radioactive contamination on the phenotype of free-living organisms are poorly understood, mainly because of the difficulty of capturing the large numbers of individual specimens that are required to quantify rare events such as albinism and tumour formation. We hypothesized that the frequency of abnormalities like albinism and the frequency of radiation-induced diseases like cancer would increase with the level of background radiation, that the two markers of radiation would be positively correlated, and that the reduction in abundance of animals would be greater in species with a higher frequency of albinism and tumour formation, if these markers reliably reflected poor viability. Here we analyzed the frequency of albinistic feathers and tumours in a sample of 1669 birds captured during 2010-2012 at eight sites around Chernobyl that varied in level of background radiation from 0.02 to more than 200μSv/h. We recorded 111 cases of partial albinism and 25 cases of tumour formation. Nominal logistic models were used to partition the variance into components due to species and background radiation. Radiation was a strong predictor of the two markers in birds, with a small, but significant effect of species for albinism. The slope of the relationship between abundance and radiation in different bird species was significantly inversely correlated with the frequency of albinism and tumours, as was to be expected if a common underlying cause (i.e. radiation) affects both variables. These findings are consistent with the hypothesis that background radiation is a cause of albinism and tumours, that albinism and tumours are biomarkers of radiation exposure, and that high frequencies of albinism and tumours were present despite the low viability of birds with these conditions. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Anti-tumour action of 64Cu-bleomycin on Ehrlich ascites tumour cells in vivo

    International Nuclear Information System (INIS)

    Maki, Hirotoshi; Kawai, Kenichi; Akaboshi, Mitsuhiko

    1979-01-01

    The anti-tumor action of the complex of Bleomycin (BLM) with high specific-radioactivity 64 Cu on Ehrlich ascites tumour (EAT) was studied in vivo. The 64 Cu-BLM was administered into intraperitoneal cavity of mice from 1 to 4 days after inoculation of EAT cells. The effect of 64 Cu-BLM to suppress the tumour growth as demonstrated by prolonging life span was observed. The amounts of 64 Cu-BLM (800 μCi-8 mg/Kg) were administered at 4, 8 and 16 times separately. Then, the shorter the time interval and the less the amounts of drugs at a time, the higher the suppressing effect for the tumour growth was. It was confirmed that anti-tumour action of 64 Cu-BLM was in all the cases higher than that of BLM alone. (author)

  10. Synchronous and Metachronous Malignant Tumours expect the un-expected

    International Nuclear Information System (INIS)

    Mehdi, I.; Shah, A.H.; Moona, M.S.; Verma, K.; Abussa, A.; Elramih, R.; El-Hashmi, H.

    2010-01-01

    Objective: To evaluate occurrence of synchronous and metachronous malignant tumours, to find tumour types, age group, and relationship to treatment received. Methods: Previously diagnosed first primary tumour cases experiencing a synchronous or metachronous tumour, seen at AOI from February 2003 to August 2009 (78 months) were included. The cases were analyzed for morphology/histology of first primary tumour, age and gender of patient, treatment received for first tumour, time interval between the first and second primary tumour, morphology/histology of second tumour, and the treatment conferred for second tumour. Results: The second synchronous and metachronous tumours were 46/4025 (1.14%), in 18 males and 28 females (M:F 1:1.6). The age range was 16-75 years (median 43 years). The follow up time was 24-150 months. The time to second primary tumour was 2-132 months. The first primary tumours were breast, ovary, GIT and urinary bladder. The patients received surgery, radiotherapy, chemotherapy, and hormonal therapy alone or as multi-modality treatment for the first tumours. The frequent second tumours were breast, ovary and Gastro Intestinal tumours. Conclusion: It is imperative that patients with a primary malignant tumour should be thoroughly, closely, and regularly followed. Genetic counseling, risk estimation, cancer screening and hemo prevention must be emphasized. Every subsequent occurring tumour should be biopsied. The effect of first tumour on the second or vice versa are still not fully understood and need exploration. The second primary tumour is usually more aggressive, treatment resistant, and metastasizes early requiring a more aggressive treatment strategy. (author)

  11. MHC class II molecules and tumour immunotherapy

    International Nuclear Information System (INIS)

    Oven, I.

    2005-01-01

    Background. Tumour immunotherapy attempts to use the specificity and capability of the immune system to kill malignant cells with a minimum damage to normal tissue. Increasing knowledge of the identity of tumour antigens should help us design more effective therapeutic vaccines. Increasing evidence has demonstrated that MHC class II molecules and CD4+ T cells play important roles in generating and maintaining antitumour immune responses in animal models. These data suggest that it may be necessary to involve both CD4+ and CD8+ T cells for more effective antitumour therapy. Novel strategies have been developed for enhancing T cell responses against cancer by prolonging antigen presentation of dendritic cells to T cells, by the inclusion of MHC class II-restricted tumour antigens and by genetically modifying tumour cells to present antigen to T lymphocytes directly. Conclusions. Vaccines against cancers aim to induce tumour-specific effector T cells that can reduce tumour mass and induce development of tumour-specific T cell memory, that can control tumour relapse. (author)

  12. Oestrogen receptors in breast tumours: associations with age, menopausal status and epidemiological and clinical features in 735 patients.

    Science.gov (United States)

    Elwood, J M; Godolphin, W

    1980-11-01

    Comparisons between oestrogen-receptor (RE)-positive or negative patients were made on a continuous series of 735 patients with primary breast tumours seen at the major treatment centre in British Columbia between 1975 and 1978. RE positivity was commoner in older patients, and was not associated with menopausal status independently of age. The concentration of receptor protein also increased with increasing age, but was not affected by menopausal status. Neither RE status nor quantity was associated with any of the epidemiological risk factors studied, which included parity, age at first birth, weight, family history and exposure to oestrogenic drugs and oral contraceptives. Patients with RE- tumours were more likely to present with symptoms other than a breast lump, pain or nipple inversion, and had less-differentiated tumours; they did not differ from RE+ patients in terms of stage, size of tumour, or interval from first symptom. These findings are discussed in terms of the biological origin and determinants of oestrogen receptors.

  13. Imaging of solid kidney tumours in children

    International Nuclear Information System (INIS)

    Hugosson, C.; Nyman, R.; Jacobsson, B.; Jorulf, H.; Sackey, K.; McDonald, P.

    1995-01-01

    Eighteen children aged 6 months to 12 years with 20 solid renal tumours; 13 Wilms' tumours (WT), 2 clear cell sarcomas of the kidney, 1 malignant rhabdoid tumour of the kidney and 2 cases of bilateral nephroblastomatosis with Wilms' tumour underwent evaluation with US, CT and MR imaging. Contrast-enhanced CT and non-enhanced MR were equally accurate in determining the size and origin of the tumour but were unreliable in separation of stages I, II and III. US could only accurately assess the size of the tumours. MR characteristics varied somewhat between WTs and non-WTs but contrast-enhanced MR imaging might be useful for separation of WTs from nephroblastomatosis. (orig.)

  14. Treatment Of Brain Tumours In Childhood

    International Nuclear Information System (INIS)

    Stancokova, T.

    2007-01-01

    Children tumours are the second most common oncologic diseases in childhood (20 %) with highest incidence of mortality in children oncology. Brain tumours form a heterogenous group of tumours with their classification,diagnostic criteria and therapeutic modalities. General principles of treatment involve neurosurgery, which is a prognostic factor, its radicality depends on localization. Radiotherapy has limitations in children until 3 years for possible late effects. Chemotherapy is effective in tumours with high growing rate. These days challenge is to improve therapeutic outcomes and minimalize toxicity of therapy. (author)

  15. MRI appearances of borderline ovarian tumours

    Energy Technology Data Exchange (ETDEWEB)

    Bent, C.L. [Department of Diagnostic Imaging, St Bartholomew' s Hospital, West Smithfield, London (United Kingdom)], E-mail: clare.bent@bartsandthelondon.nhs.uk; Sahdev, A.; Rockall, A.G. [Department of Diagnostic Imaging, St Bartholomew' s Hospital, West Smithfield, London (United Kingdom); Singh, N. [Department of Pathology, St Bartholomew' s Hospital, West Smithfield, London (United Kingdom); Sohaib, S.A. [Department of Radiology, Royal Marsden Hospital, London (United Kingdom); Reznek, R.H. [Cancer Imaging, St Bartholomew' s Hospital, West Smithfield, London (United Kingdom)

    2009-04-15

    This review was performed to describe the range of magnetic resonance imaging (MRI) appearances of borderline ovarian tumours. The MRI findings in 26 patients with 31 borderline ovarian tumours (mean age: 40.1 years, range: 14-85 years) were retrospectively reviewed. For each tumour, site, size, MRI characteristics, and enhancement following gadolinium administration were recorded. There were 20 serous and 11 mucinous borderline ovarian subtypes. Nine of 26 patients demonstrated bilateral disease on MRI; synchronous contralateral ovarian disease included three benign, five serous borderline, and one serous invasive tumour. A history of a metachronous mucinous borderline tumour was identified in one patient. MRI appearances were classified into four morphological categories: group 1 (6/31, 19%), unilocular cysts; group 2 (6/31, 19%), minimally septate cysts with papillary projections; group 3 (14/31, 45%), markedly septate lesions with plaque-like excrescences; and group 4 (5/31, 16%), predominantly solid with exophytic papillary projections, all of serous subtype. There was a significant difference in mean volume between serous (841.5 cm{sup 3}) and mucinous (6358.2 cm{sup 3}) subtypes (p = 0.009). All tumours demonstrated at least one MRI feature suggestive of malignancy. The present review demonstrates the variable MRI appearances of borderline ovarian tumours along with imaging features suggestive of tumour subtype. In patients in whom the clinical features are suggestive of a borderline ovarian tumour (young age and normal or minimally elevated CA125), the ability to predict a borderline disease using morphological features observed on MRI would be extremely helpful in surgical planning, with the potential to offer fertility or ovary-preserving surgery. Future studies are required to further this aim.

  16. Determination of tumour hypoxia with the PET tracer [18F]EF3: improvement of the tumour-to-background ratio in a mouse tumour model

    International Nuclear Information System (INIS)

    Christian, Nicolas; Bol, Anne; Bast, Marc de; Labar, Daniel; Lee, John; Mahy, Pierre; Gregoire, Vincent

    2007-01-01

    The 2-(2-nitroimidazol-1-yl)-N-(3,3,3-trifluoropropyl)acetamide (EF3) is a 2-nitroimidazole derivative which undergoes bioreductive activation under hypoxic conditions. Using the PET tracer [ 18 F]EF3 in mice, tumour-to-muscle ratios ranging from 1.3 to 3.5 were observed. This study investigated the impact of various interventions aimed at increasing [ 18 F]EF3 elimination, thus potentially increasing the tumour-to-noise ratio in mice, by increasing the renal filtration rate (spironolactone, furosemide), decreasing tubular re-absorption (metronidazole, ornidazole, amino acid solution) or stimulating gastro-intestinal elimination (phenobarbital). C3H mice were injected i.v. with an average of 12.95 MBq of [ 18 F]EF3. Drugs were injected i.v. 15 min before the tracer or daily 4 days prior to the experiment (phenobarbital). Anaesthetised mice were imaged from 30 to 300 min with a dedicated animal PET (Mosaic, Philips). Regions of interest were delineated around the tumour, bladder, heart, liver and leg muscle. Radioactivity was expressed as a percentage of injected activity per gram of tissue. Ornidazole decreased the urinary excretion and increased the liver uptake of [ 18 F]EF3, but without causing any changes in the other organs. Phenobarbital significantly increased the liver concentration and decreased radioactivity in blood and muscle without affecting the tracer uptake in tumour. Consequently, a small but non-significant increase in tumour-to-noise ratio was observed. Although some effects were observed with other drugs, they did not modify the tumour-to-noise ratio. Only phenobarbital induced a trend toward an increased tumour-to-noise ratio that could possibly be tested in the clinical situation. (orig.)

  17. CNS embryonal tumours: WHO 2016 and beyond.

    Science.gov (United States)

    Pickles, J C; Hawkins, C; Pietsch, T; Jacques, T S

    2018-02-01

    Embryonal tumours of the central nervous system (CNS) present a significant clinical challenge. Many of these neoplasms affect young children, have a very high mortality and therapeutic strategies are often aggressive with poor long-term outcomes. There is a great need to accurately diagnose embryonal tumours, predict their outcome and adapt therapy to the individual patient's risk. For the first time in 2016, the WHO classification took into account molecular characteristics for the diagnosis of CNS tumours. This integration of histological features with genetic information has significantly changed the diagnostic work-up and reporting of tumours of the CNS. However, this remains challenging in embryonal tumours due to their previously unaccounted tumour heterogeneity. We describe the recent revisions made to the 4th edition of the WHO classification of CNS tumours and review the main changes, while highlighting some of the more common diagnostic testing strategies. © 2017 British Neuropathological Society.

  18. How to perform 3D reconstruction of skull base tumours.

    Science.gov (United States)

    Bonne, N-X; Dubrulle, F; Risoud, M; Vincent, C

    2017-04-01

    The surgical management of skull base lesions is difficult due to the complex anatomy of the region and the intimate relations between the lesion and adjacent nerves and vessels. Minimally invasive approaches are increasingly used in skull base surgery to ensure an optimal functional prognosis. Three-dimensional (3D) computed tomography (CT) reconstruction facilitates surgical planning by visualizing the anatomical relations of the lesions in all planes (arteries, veins, nerves, inner ear) and simulation of the surgical approach in the operating position. Helical CT angiography is performed with optimal timing of the injection in terms of tumour and vessel contrast enhancement. 3D definition of each structure is based on colour coding by automatic thresholding (bone, vessels) or manual segmentation on each slice (tumour, nerves, inner ear). Imaging is generally presented in 3 dimensions (superior, coronal, sagittal) with simulation of the surgical procedure (5 to 6 reconstructions in the operating position at different depths). Copyright © 2016. Published by Elsevier Masson SAS.

  19. Tumour-associated endothelial-FAK correlated with molecular sub-type and prognostic factors in invasive breast cancer

    International Nuclear Information System (INIS)

    Alexopoulou, Annika N; Ho-Yen, Colan M; Papalazarou, Vassilis; Elia, George; Jones, J Louise; Hodivala-Dilke, Kairbaan

    2014-01-01

    Breast cancer is a heterogeneous disease that can be classified into one of 4 main molecular sub-types: luminal A, luminal B, Her2 over-expressing and basal-like (BL). These tumour sub-types require different treatments and have different risks of disease progression. BL cancers can be considered a sub-group of Triple negative (TN) cancers since they lack estrogen (ER), progesterone (PR) and Her2 expression. No targeted treatment currently exists for TN/BL cancers. Thus it is important to identify potential therapeutic targets and describe their relationship with established prognostic factors. Focal adhesion kinase (FAK) is upregulated in several human cancers and also plays a functional role in tumour angiogenesis. However, the association between breast cancer sub-types and tumour endothelial-FAK expression is unknown. Using immunofluorescence, we quantified FAK expression in tumour endothelial and tumour cell compartments in 149 invasive breast carcinomas and correlated expression with clinical, pathological and molecular parameters. Low endothelial-FAK expression was independently associated with luminal A tumours at univariate (p < 0.001) and multivariate (p = 0.001) analysis. There was a positive correlation between FAK expression in the vascular and tumour cell compartments (Spearman’s correlation co-efficient = 0.394, p < 0.001). Additionally, endothelial and tumour cell FAK expression were significantly increased in TN tumours (p = 0.043 and p = 0.033 respectively), in tumours with negative ER and PR status, and in high grade tumours at univariate analysis. Our findings establish a relationship between endothelial-FAK expression levels and the molecular sub-type of invasive breast cancer, and suggest that endothelial-FAK expression is potentially more clinically relevant than tumour cell FAK expression in breast cancer

  20. Tumour and lymph node uptakes on dual-phased 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography correlate with prognostic parameters in breast cancer.

    Science.gov (United States)

    Chang, Chin-Chuan; Tu, Hung-Pin; Chen, Yu-Wen; Lin, Chia-Yang; Hou, Ming-Feng

    2014-12-01

    To examine correlations between the uptake of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) by primary tumours and axillary lymph nodes, and clinical and biological tumour prognostic parameters, in patients with newly diagnosed breast cancer. Newly diagnosed breast cancer patients who had received a dual-phased FDG positron emission tomography/computed tomography scan for pretreatment staging were enrolled retrospectively. Maximal standardized uptake values at 1 h (SUV1), 2 h (SUV2), and retention indices (RI) of the tumours and ipsilateral axillary lymph nodes were measured. SUV and RI were compared with clinical and biological prognostic parameters. A total of 32 patients participated in the study. Tumour FDG uptake correlated with histological grade and tumour size. FDG uptake in axillary lymph nodes correlated positively with lymph node status, metastasis status and clinical stage. RI values for the tumour and lymph nodes were significantly positively correlated with human epidermal growth factor receptor-2 positivity. FDG uptake in tumours and lymph nodes showed correlations with some clinical and biological parameters, and may serve as a predictive marker of tumour biological behaviour in breast cancer. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Menopausal status dependence of the timing of breast cancer recurrence after surgical removal of the primary tumour

    International Nuclear Information System (INIS)

    Demicheli, Romano; Bonadonna, Gianni; Hrushesky, William JM; Retsky, Michael W; Valagussa, Pinuccia

    2004-01-01

    Information on the metastasis process in breast cancer patients undergoing primary tumour removal may be extracted from an analysis of the timing of clinical recurrence. The hazard rate for local-regional and/or distant recurrence as the first event during the first 4 years after surgery was studied in 1173 patients undergoing mastectomy alone as primary treatment for operable breast cancer. Subset analyses were performed according to tumour size, axillary nodal status and menopausal status. A sharp two-peaked hazard function was observed for node-positive pre-menopausal patients, whereas results from node-positive post-menopausal women always displayed a single broad peak. The first narrow peak among pre-menopausal women showed a very steep rise to a maximum about 8–10 months after mastectomy. The second peak was considerably broader, reaching its maximum at 28–30 months. Post-menopausal patients displayed a wide, nearly symmetrical peak with maximum risk at about 18–20 months. Peaks displayed increasing height with increasing axillary lymph node involvement. No multi-peaked pattern was evident for either pre-menopausal or post-menopausal node-negative patients; however, this finding should be considered cautiously because of the limited number of events. Tumour size influenced recurrence risk but not its timing. Findings resulting from the different subsets of patients were remarkably coherent and each observed peak maintained the same position on the time axis in all analysed subsets. The risk of early recurrence for node positive patients is dependent on menopausal status. The amount of axillary nodal involvement and the tumour size modulate the risk value at any given time. For pre-menopausal node-positive patients, the abrupt increase of the first narrow peak of the recurrence risk suggests a triggering event that synchronises early risk. We suggest that this event is the surgical removal of the primary tumour. The later, broader, more symmetrical risk

  2. Primary bone tumours in infants

    Energy Technology Data Exchange (ETDEWEB)

    Kozlowski, K.; Beluffi, G.; Cohen, D.H.; Padovani, J.; Tamaela, L.; Azouz, M.; Bale, P.; Martin, H.C.; Nayanar, V.V.; Arico, M.

    1985-09-01

    Ten cases of primary bone tumours in infants (1 osteosarcoma, 3 Ewing's sarcoma, 1 chondroblastoma and 5 angiomastosis) are reported. All cases of angiomatosis showed characteristic radiographic findings. In all the other tumours the X-ray appearances were different from those usually seen in older children and adolescents. In the auhtors' opinion the precise diagnosis of malignant bone tumours in infancy is very difficult as no characteristic X-ray features are present in this age period.

  3. Long-term exposure to ambient air pollution and incidence of brain tumours: The Danish Nurse Cohort

    DEFF Research Database (Denmark)

    Jørgensen, Jeanette Therming; Johansen, Martin Søes; Ravnskjær, Line

    2016-01-01

    -reported information on lifestyle was collected. We obtained data on the incidence of brain tumours until 2013 from the Danish Cancer Register, and estimated annual mean concentrations of particulate matter with diameterPM2.5), particulate matter with diameter... positive association between total brain tumours and PM2.5 (1.06; 0.80-1.40 per 3.37μg/m(3)), NO2 (1.09; 0.91-1.29) per 7.5μg/m(3), and NOx (1.02; 0.93-1.12 per 10.22μg/m(3)), and none with PM10 (0.93; 0.70-1.23 per 3.31μg/m(3)). Associations with PM2.5 and NO2 were stronger for tumours located in meninges...... than in brain, and for benign than for malignant tumours. Finally, association of total brain tumours with PM2.5 was modified by BMI, and was statistically significantly enhanced in obese women (2.03; 1.35-3.05). CONCLUSION: We found weak evidence for association between risk of brain tumours and long...

  4. Preoperative estimation of the pathological breast tumour size by physical examination, mammography and ultrasound: a prospective study on 105 invasive tumours

    International Nuclear Information System (INIS)

    Bosch, Anne M.; Kessels, Alfons G.H.; Beets, Geerard L.; Rupa, Jan D.; Koster, Dick; Engelshoven, Jos M.A. van; Meyenfeldt, Maarten F. von

    2003-01-01

    Objective: The clinical breast tumour size can be assessed preoperatively by physical examination, mammography and ultrasound. At present it is not clear which modality correlates best with the histological invasive breast tumour size. This prospective study aims to determine the most accurate clinical method (physical examination, mammography or ultrasound) to predict the histological invasive tumour size preoperatively. Methods and patients: Between October 1999 and August 2000, 96 women with 105 invasive malignant breast tumours were included in this study. All patients underwent excision and the tumour size was measured on histology. Tumour size was measured by all three modalities in 73 cases. Results were evaluated by calculating correlation coefficients. The examination modalities presenting the best estimation of the pathological tumour size were used in a stepwise linear regression analysis to construct a formula predicting the pathological tumour size from the result of the various diagnostic modalities. Results: The correlation coefficient between ultrasound and pathological size (r=0.68) was significantly better than the correlations between physical examination and pathological size (r=0.42) and mammographic and pathological size (r=0.44). Physical examination overestimates and ultrasound underestimates breast tumour classification. The most accurate prediction formula was: Pathological tumour size (mm) equals sonographic tumour size (mm)+3 mm. Conclusion: When comparing physical examination, mammography and ultrasound for the prediction of the pathological size of a malignant breast tumour, ultrasound is the best predictor. The ensuing regression formula determines pathological size as tumour size by ultrasound+3 mm. However, with the wide 95% confidence interval of ±11 mm, it remains difficult to predict the exact pathological size for an individual invasive breast tumour. A small deviation in millimetres of the tumour size could lead to a change in

  5. Tumours of the fetal body: a review

    Energy Technology Data Exchange (ETDEWEB)

    Avni, Fred E.; Massez, Anne; Cassart, Marie [University Clinics of Brussels - Erasme Hospital, Department of Medical Imaging, Brussels (Belgium)

    2009-11-15

    Tumours of the fetal body are rare, but lesions have been reported in all spaces, especially in the mediastinum, the pericardial space, the adrenals, the kidney, and the liver. Lymphangioma and teratoma are the commonest histological types encountered, followed by cardiac rhabdomyoma. Adrenal neuroblastoma is the commonest malignant tumour. Imaging plays an essential role in the detection and work-up of these tumours. In addition to assisting clinicians it also helps in counselling parents. Most tumours are detected by antenatal US, but fetal MRI is increasingly used as it brings significant additional information in terms of tumour extent, composition and complications. (orig.)

  6. Impact of F DOPA-PET on therapeutic decision in endocrine tumours: digestive tumours, medullary thyroid cancer or pheochromocytoma

    International Nuclear Information System (INIS)

    Montravers, F.; Grahek, D.; Kerrou, K.; Gutman, F.; Beco, V. de; Nataf, V.; Balard, M.; Talbot, J.N.

    2006-01-01

    FDOPA-PET has been proposed for a decade in oncology, in particular in endocrine tumours. To the best of our knowledge, only one impact rate has been reported: 31% in 17 patients with digestive carcinoid tumours. We did a questionnaire survey to evaluate this impact reported by the referring clinician in 87 patients who had FDOPA PET due to digestive carcinoid tumour or another type of digestive endocrine tumour or a medullary thyroid cancer or a pheochromocytoma. The response rate to the survey was 87%. The overall impact of FDOPA PET on patient's management was 36%. Its value was greater for digestive carcinoid tumour and for medullary thyroid cancer; the number of patients with pheochromocytoma is still limited. In the other digestive endocrine tumours, a change in patient management was less frequent and FDOPA PET should be performed when the other examinations are inconclusive. (author)

  7. Pasteurization of bone for tumour eradication prior to reimplantation – An in vitro & pre-clinical efficacy study

    Science.gov (United States)

    Kode, Jyoti; Taur, Prasad; Gulia, Ashish; Jambhekar, Nirmala; Agarwal, Manish; Puri, Ajay

    2014-01-01

    Background & objectives: In current era of limb-salvage therapy, pasteurization of bone sarcomas is receiving growing attention as a potential extracorporeal treatment and cost-effective alternative to allografts and radiation before surgical reimplantation. Detailed in vitro and in vivo pre-clinical study to evaluate efficacy of pasteurization to eradicate malignant cells has not been reported yet. The present study was carried out to assess the efficacy of pasteurization to kill tumour cells both in vitro and in vivo. Methods: Surgically resected specimens of osteosarcomas (n=4) were cut into equal halves and one section was pasteurized by heating at 60°C to 65°C for 40 min. Paired samples before and after pasteurization were studied in vitro for DNA ploidy, evaluation of histological change and elimination of mitotic activity. These tissues were transplanted in immune-deficient NOD-SCID mice to evaluate effect on tumour-generating ability, presence of human nuclei, osteopontin and cytokine/chemokines released in tumour-transplanted mice. Results: Non-pasteurized tumour samples had viable tumour cells which exhibited significant growth in culture, increased proliferative ability and clonogenic potential while respective pasteurized tumour tissues did not grow in culture and did not exhibit clonogenicity. Flow cytometry revealed that propidium iodide positive dead cells increased significantly (Ppasteurization. Seven of 12 non-pasteurized tumour transplanted mice demonstrated tumour-forming ability as against 0 of 12 in pasteurized tumour transplanted mice. Solid tumour xenografts exhibited strong expression of anti-human nuclei and osteopontin by immunohistochemistry as well as secretary human interluekin-6 (IL-6) while pasteurized mice failed to express these markers. Interpretation & conclusions: This study has provided a basis to establish pasteurization as being efficacious in ensuring tumour eradication from resected bone tumour specimens. Pasteurized

  8. Metformin treatment modulates the tumour-induced wasting effects in muscle protein metabolism minimising the cachexia in tumour-bearing rats

    International Nuclear Information System (INIS)

    Oliveira, André G.; Gomes-Marcondes, Maria Cristina C.

    2016-01-01

    Cancer-cachexia state frequently induces both fat and protein wasting, leading to death. In this way, the knowledge of the mechanism of drugs and their side effects can be a new feature to treat and to have success, contributing to a better life quality for these patients. Metformin is an oral drug used in type 2 diabetes mellitus, showing inhibitory effect on proliferation in some neoplastic cells. For this reason, we evaluated its modulatory effect on Walker-256 tumour evolution and also on protein metabolism in gastrocnemius muscle and body composition. Wistar rats received or not tumour implant and metformin treatment and were distributed into four groups, as followed: control (C), Walker 256 tumour-bearing (W), metformin-treated (M) and tumour-bearing treated with metformin (WM). Animals were weighed three times a week, and after cachexia state has been detected, the rats were euthanised and muscle and tumour excised and analysed by biochemical and molecular assays. Tumour growth promoted some deleterious effects on chemical body composition, increasing water and decreasing fat percentage, and reducing lean body mass. In muscle tissue, tumour led to a decreased protein synthesis and an increased proteolysis, showing the higher activity of the ubiquitin-proteasome pathway. On the other hand, the metformin treatment likely minimised the tumour-induced wasting state; in this way, this treatment ameliorated chemical body composition, reduced the higher activities of proteolytic enzymes and decreased the protein waste. Metformin treatment not only decreases the tumour growth but also improves the protein metabolism in gastrocnemius muscle in tumour-bearing rats

  9. Tumours in white suckers from Lake Michigan tributaries: Pathology and prevalence

    Science.gov (United States)

    Blazer, Vicki S.; Walsh, H.L.; Braham, R.P.; Hahn, C. M.; Mazik, P.; McIntyre, P.B.

    2016-01-01

    The prevalence and histopathology of neoplastic lesions were assessed in white suckerCatostomus commersonii captured at two Lake Michigan Areas of Concern (AOCs), the Sheboygan River and Milwaukee Estuary. Findings were compared to those observed at two non-AOC sites, the Root and Kewaunee rivers. At each site, approximately 200 adult suckers were collected during their spawning migration. Raised skin lesions were observed at all sites and included discrete white spots, mucoid plaques on the body surface and fins and large papillomatous lesions on lips and body. Microscopically, hyperplasia, papilloma and squamous cell carcinoma were documented. Liver neoplasms were also observed at all sites and included both hepatocellular and biliary tumours. Based on land use, the Kewaunee River was the site least impacted by human activities previously associated with fish tumours and had significantly fewer liver neoplasms when compared to the other sites. The proportion of white suckers with liver tumours followed the same patterns as the proportion of urban land use in the watershed: the Milwaukee Estuary had the highest prevalence, followed by the Root, Sheboygan and Kewaunee rivers. The overall skin neoplasm (papilloma and carcinoma) prevalence did not follow the same pattern, although the percentage of white suckers with squamous cell carcinoma exhibited a similar relationship to land use. Testicular tumours (seminoma) were observed at both AOC sites but not at the non-AOC sites. Both skin and liver tumours were significantly and positively associated with age but not sex.

  10. Concomitant expression of several peptide receptors in neuroendocrine tumours: molecular basis for in vivo multireceptor tumour targeting

    International Nuclear Information System (INIS)

    Reubi, Jean Claude; Waser, Beatrice

    2003-01-01

    Peptide receptors have been found to represent excellent targets for in vivo cancer diagnosis and therapy. Recent in vitro studies have shown that many cancers can overexpress not only one but several peptide receptors concomitantly. One of the challenges for nuclear medicine in this field in the coming decade will be to take advantage of the co-expression of peptide receptors for multireceptor tumour targeting. In vitro receptor studies can reveal which peptide receptor is overexpressed in which tumour and which receptors are co-expressed in an individual tumour; such knowledge is a prerequisite for successful in vivo development. One group of tumours of particular interest in this respect is the neuroendocrine tumours, which have previously been shown often to express peptide receptors. This review summarises our investigations of the concomitant expression of 13 different peptide receptors, in more than 100 neuroendocrine tumours of the human intestine, pancreas and lung, using in vitro receptor autoradiography with subtype-selective ligands. The incidence and density of the somatostatin receptors sst 1 -sst 5 , the VIP receptors VPAC 1 and VPAC 2 , the CCK 1 and CCK 2 receptors, the three bombesin receptor subtypes BB 1 (NMB receptor), BB 2 (GRP receptor) and BB 3 , and GLP-1 receptors were evaluated. While the presence of VPAC 1 and sst 2 was detected in the majority of these neuroendocrine tumours, the other receptors, more differentially expressed, revealed a characteristic receptor pattern in several tumour types. Ileal carcinoids expressed sst 2 and VPAC 1 receptors in virtually all cases and had CCK 1 , CCK 2 , sst 1 or sst 5 in approximately half of the cases; they were the only tumours of this series to express NMB receptors. Insulinomas were characterised by a very high incidence of GLP-1, CCK 2 and VPAC 1 receptors, with the GLP-1 receptors expressed in a particularly high density; they expressed sst 2 in two-thirds and sst 1 in approximately half of

  11. Diagnostic value of quantitative scintiscanning in tumours and tumour-like lesions of the skeleton

    International Nuclear Information System (INIS)

    Schmitt-Orlewicz, C.

    1986-01-01

    Following administration of 99mTc phosphate compounds quantitative scintiscanning and, in particular, the 'region of interest' technique were used in 277 patients investigated for tumours and tumour-like lesions of the extremities. The following results were obtained: 1) In primary malignant bone tumours of the extremities tracer accumulation is increased by a factor of more than 2.5 as compared to that observed in normal bone tissue (the only exception here being plasmacytoma and histiocytoma). 2) In metastatic and benign bone tumours this tendency towards increased tracer accumulation generally is less pronounced so that the values calculated here remained below a factor of 2.5. 3) The accumulation behaviour of tumour-like bone changes of the extremities did not follow a uniform pattern. 4) As a general rule, the values measured in the region of the vertebral column were increased by a factor of less than 2.5. Quantitative scintiscanning, even though being a step towards a more sophisticated radiopharmaceutical method of examination, may occasionally not provide all the information required to establish a firm diagnosis or to evaluate the severity of a disease. One important domaine of this technique is the medical surveillance of patients, both before and after treatment. (TRV) [de

  12. [Mobile phones and head tumours: it is time to read and highlight data in a proper way].

    Science.gov (United States)

    Levis, Angelo G; Minicucci, Nadia; Ricci, Paolo; Gennaro, Valerio; Garbisa, Spiridione

    2011-01-01

    The uncertainty about the relationship between the use of mobile phones (MPs: analogue and digital cellulars, and cordless) and the increase of head tumour risk can be solved by a critical analysis of the methodological elements of both the positive and the negative studies. Results by Hardell indicate a cause/effect relationship: exposures for or latencies from ≥ 10 years to MPs increase by up to 100% the risk of tumour on the same side of the head preferred for phone use (ipsilateral tumours) - which is the only one significantly irradiated - with statistical significance for brain gliomas, meningiomas and acoustic neuromas. On the contrary, studies published under the Interphone project and others produced negative results and are characterised by the substantial underestimation of the risk of tumour. However, also in the Interphone studies a clear and statistically significant increase of ipsilateral head tumours (gliomas, neuromas and parotid gland tumours) is quite common in people having used MPs since or for ≥ 10 years. And also the metaanalyses by Hardell and other Authors, including only the literature data on ipsilateral tumours in people having used MPs since or for ≥ 10 years - and so also part of the Interphone data - still show statistically significant increases of head tumours.

  13. Childhood Adrenocortical Tumours: a Review

    Directory of Open Access Journals (Sweden)

    Marques-Pereira Rosana

    2006-05-01

    Full Text Available Abstract Childhood adrenocortical tumour (ACT is not a common disease, but in southern Brazil the prevalence is 15 times higher than in other parts of the world. One hundred and thirty-seven patients have been identified and followed by our group over the past four decades. Affected children are predominantly girls, with a female-to-male ratio of 3.5:1 in patients below 4 years of age. Virilization alone (51.6% or mixed with Cushing's syndrome (42.0% was the predominant clinical picture observed in these patients. Tumours are unilateral, affecting both glands equally. TP53 R337H germline mutations underlie most childhood ACTs in southern Brazil. Epidemiological data from our casuistic studies revealed that this mutation has ~10% penetrance for ACT. Surgery is the definitive treatment, and a complete resection should always be attempted. Although adjuvant chemotherapy has shown some encouraging results, its influence on overall outcome is small. The survival rate is directly correlated to tumour size; patients with small, completely excised tumours have survival rates close to 90%, whereas in those patients with inoperable tumours and/or metastatic disease it is less than 10%. In the group of patients with large, excisable tumours, half of them have an intermediate outcome. Recent molecular biology techniques and genomic approaches may help us to better understand the pathogenesis of ACT, the risk of developing a tumour when TP53 R337H is present, and to predict its outcome. An ongoing pilot study consisting of close monitoring of healthy carriers of the TP53 R337H mutation - siblings and first-degree relatives of known affected cases - aims at the early detection of ACTs and an improvement of the cure rate.

  14. Surgical approach to pineal tumours.

    Science.gov (United States)

    Pluchino, F; Broggi, G; Fornari, M; Franzini, A; Solero, C L; Allegranza, A

    1989-01-01

    During a period of 10 years (1977-1986) 40 cases of tumour of the pineal region have been treated at the Istituto Neurologico "C. Besta"-of Milan. Out of these 40 cases, 27 (67.5%) were in the paediatric (10-15 years) or juvenile (15-20 years) age at the time of operation. Since 1983 a specific diagnostic and therapeutic protocol has been adopted and thereafter direct surgical removal of the tumour was performed only when the neuroradiological investigations were highly suggestive of a benign extrinsic lesion. Sixteen cases in this series underwent direct surgical removal; in the remaining 24 cases stereotactic biopsy of the tumour was performed in the first instance. On the basis of the histological diagnosis obtained by this procedure surgical excision of the tumour (9 cases) or radiotherapy (15 cases) was then performed. 25 cases underwent surgical removal of the lesion. In all the cases the infratentorial supracerebellar approach as introduced by Krause and then modified by Stein was adopted. On analysis of the data of this series it was observed that in 25% of the cases completely benign resectable tumours were found; in 25% of the cases astrocytoma (grade I-II) which could be treated at least by partial removal were present; in 30% of the cases radiosensitive lesions were encountered. In the remaining 20% of the cases highly malignant tumours were found which should be treated only by radiotherapy and/or chemotherapy.

  15. Malignant tumours of the kidney: imaging strategy

    International Nuclear Information System (INIS)

    Smets, Anne M.; Kraker, Jan de

    2010-01-01

    Primitive malignant renal tumours comprise 6% of all childhood cancers. Wilms tumour (WT) or nephroblastoma is the most frequent type accounting for more than 90%. Imaging alone cannot differentiate between these tumours with certainty but it plays an important role in screening, diagnostic workup, assessment of therapy response, preoperative evaluation and follow-up. The outcome of WT after therapy is excellent with an overall survival around 90%. In tumours such as those where the outcome is extremely good, focus can be shifted to a risk-based stratification to maintain excellent outcome in children with low risk tumours while improving quality of life and decreasing toxicity and costs. This review will discuss the imaging issues for WT from the European perspective and briefly discuss the characteristics of other malignant renal tumours occurring in children and new imaging techniques with potential in this matter. (orig.)

  16. Cystic tumours of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Tsukuba Univ. (Japan); Ohtomo, K. [Univ. of Tokyo Hospital, Tokyo (Japan)

    1996-12-01

    In this pictorial essay we present the typical appearances of cystic pancreatic tumours, the wide spectrum of their features, and differential features among cystic pancreatic masses with an emphasis on CT. Pseudocysts are the most common cystic lesion in the pancreas and can be induced by pancreatitis, trauma or surgery. Pseudocysts appear as a round cystic mass with a definite wall. However, they can mimic cystic tumours associated with internal septation and/or necrotic mass of various shapes. Conversely, cystic tumours can appear as a simple cyst lacking any thickening of wall, septation or mural nodule. Pancreatic carcinoma not infrequently induces secondary cysts upstream of the obstructed pancreatic duct. The cysts are pseudocysts or retention cysts in nature. When cysts are formed in the pancreatic parenchyma or adjacent to pancreatic carcinoma they may mimic cystic tumour. (orig./VHE)

  17. Cystic tumours of the pancreas

    International Nuclear Information System (INIS)

    Itai, Y.; Ohtomo, K.

    1996-01-01

    In this pictorial essay we present the typical appearances of cystic pancreatic tumours, the wide spectrum of their features, and differential features among cystic pancreatic masses with an emphasis on CT. Pseudocysts are the most common cystic lesion in the pancreas and can be induced by pancreatitis, trauma or surgery. Pseudocysts appear as a round cystic mass with a definite wall. However, they can mimic cystic tumours associated with internal septation and/or necrotic mass of various shapes. Conversely, cystic tumours can appear as a simple cyst lacking any thickening of wall, septation or mural nodule. Pancreatic carcinoma not infrequently induces secondary cysts upstream of the obstructed pancreatic duct. The cysts are pseudocysts or retention cysts in nature. When cysts are formed in the pancreatic parenchyma or adjacent to pancreatic carcinoma they may mimic cystic tumour. (orig./VHE)

  18. SU-G-JeP1-02: A New Intra-Fractional Prostate Motion Tracking Method in Volumetric Modulated Arc Therapy (VMAT) Via 2D/3D Registration

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Y; Rezaeian, N Hassan; Hannan, R; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered images were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.

  19. Primary vertebral tumours in children

    Energy Technology Data Exchange (ETDEWEB)

    Kozlowski, K.; Beluffi, G.; Masel, J.; Diard, F.; Ferrari-Ciboldi, F.; Le Dosseur, P.; Labatut, J.

    1984-03-01

    20 cases of primary benign and malignant bone tumours in children were reported. The most common tumours were Ewing's sarcoma, aneurismal bone cyst, benign osteoblastoma and osteoid osteoma. Some rare primary bone tumours in children (osteochondroma, chondroblastoma 6F, primary lymphoma of bone and neurofibromatosis with unusual cervical spinal changes) were also reported. The authors believe that radiographic findings together with clinical history and clinical examination may yield a high percentage of accurate diagnoses. Although microscopy is essential in the final diagnosis, the microscopic report should be also accepted with caution.

  20. Testicular tumours in prepubertal children: About eight cases ...

    African Journals Online (AJOL)

    Conclusion: In prepubertal children, most testicular tumours are benign. If tumour markers were negative testis-preserving surgery can be proposed, complete excision of the tumour should be ascertained. In the case of testicular teratoma, the possibility of contralateral tumour should be considered in the follow-up.

  1. Intra-operative cerebrospinal fluid sampling versus post-operative lumbar puncture for detection of leptomeningeal disease in malignant paediatric brain tumours.

    Directory of Open Access Journals (Sweden)

    Sharon Y Y Low

    Full Text Available Leptomeningeal disease is a feared sequelae of malignant paediatric brain tumours. Current methods for its detection is the combined use of cranio-spinal MRI, and CSF cytology from a post-operative lumbar puncture. In this study, the authors hypothesize that CSF taken at the start of surgery, either from an external ventricular drain or neuroendoscope will have equal sensitivity for positive tumour cells, in comparison to lumbar puncture. Secondary hypotheses include positive correlation between CSF cytology and MRI findings of LMD. From a clinical perspective, the key aim of the study was for affected paediatric patients to avoid an additional procedure of a lumbar puncture, often performed under anaesthesia after neurosurgical intervention.This is single-institution, retrospective study of paediatric patients diagnosed with malignant brain tumours. Its main aim was to compare cytological data from CSF collected at the time of surgery versus data from an interval lumbar puncture. In addition, MRI imaging of the same cohort of patients was examined for leptomeningeal disease and corroborated against CSF tumour cytology findings.Thirty patients are recruited for this study. Data analysis demonstrates a statistically significant association between our intra-operative CSF and LP sampling. Furthermore, our results also show for significant correlation between evidence of leptomeningeal disease on MRI findings versus intra-operative CSF positivity for tumour cells.Although this is a retrospective study with a limited population, our data concurs with potential to avoid an additional procedure for the paediatric patient diagnosed with a malignant brain tumour.

  2. Mohs micrographic surgery of rare cutaneous tumours

    NARCIS (Netherlands)

    Flohil, S.C.; Lee, C.B. van; Beisenherz, J.; Mureau, M.A.M.; Overbeek, L.I.H.; Nijsten, T.; Bos, R.R.

    2017-01-01

    BACKGROUND: Recurrence rates after Mohs micrographic surgery (MMS) for rare cutaneous tumours are poorly defined. OBJECTIVE: To investigate the recurrence rate after MMS for rare cutaneous tumours at a university centre. METHODS & MATERIALS: Retrospective review of all rare cutaneous tumours treated

  3. Ultrasonography findings and tumour quantification in patients with pseudomyxoma peritonei

    International Nuclear Information System (INIS)

    Krause, J.; Bergman, A.; Graf, W.; Nilsson, A.; Mahteme, H.

    2012-01-01

    Pseudomyxoma peritonei (PMP) is a disease with various clinical presentations and the diagnostic value of ultrasonography (US) is under investigated. The purpose of this study was to identify the most common US finding in PMP and to investigate US sensitivity, specificity, positive and negative predictive value in quantifying tumour burden in different abdomino-pelvic regions in PMP patients. Between February 2006 and December 2008, 54 patients were treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) due to PMP. The results from preoperative US examination with and without intravenously administrated contrast (SonoVue) were compared to surgical findings. The mean US peritoneal cancer index (PCI) was 6 (range 0–25) and the surgical PCI was 18 (range 3–27) p < 0.0001. The histo-pathological subtypes did not influence the US findings. Ascites, bowel loops adhesions and omental cake were mostly visualised correctly by US. The sensitivity of US in quantification of tumour nodules was 91.5% (range 74–100%) and specificity was 33.8% (range 18–55%). The positive predictive value of US examination in PMP was 22% (range 11–44%) and the negative predictive value was 93% (range 77–100%). US can detect the most common PMP findings (ascites and omental cake). The sensitivity of US to quantify PMP tumour burden in different abdominio-pelvic region was relatively high, however, this imaging tool had low specificity.

  4. Cooperative tumour cell membrane targeted phototherapy

    Science.gov (United States)

    Kim, Heegon; Lee, Junsung; Oh, Chanhee; Park, Ji-Ho

    2017-06-01

    The targeted delivery of therapeutics using antibodies or nanomaterials has improved the precision and safety of cancer therapy. However, the paucity and heterogeneity of identified molecular targets within tumours have resulted in poor and uneven distribution of targeted agents, thus compromising treatment outcomes. Here, we construct a cooperative targeting system in which synthetic and biological nanocomponents participate together in the tumour cell membrane-selective localization of synthetic receptor-lipid conjugates (SR-lipids) to amplify the subsequent targeting of therapeutics. The SR-lipids are first delivered selectively to tumour cell membranes in the perivascular region using fusogenic liposomes. By hitchhiking with extracellular vesicles secreted by the cells, the SR-lipids are transferred to neighbouring cells and further spread throughout the tumour tissues where the molecular targets are limited. We show that this tumour cell membrane-targeted delivery of SR-lipids leads to uniform distribution and enhanced phototherapeutic efficacy of the targeted photosensitizer.

  5. Perinatal tumours: the contribution of radiology to management

    Energy Technology Data Exchange (ETDEWEB)

    Donoghue, Veronica; Ryan, Stephanie; Twomey, Eilish [Children' s University Hospital, Radiology Department, Dublin (Ireland)

    2008-06-15

    A formal classification does not exist and they are probably best classified by their location. Overall the most common neoplasms are - Extracranial teratoma - Neuroblastoma - Soft-tissue tumours - Brain tumours - Leukaemia - Renal tumours - Liver tumours - Retinoblastoma. The prognosis is generally poor, although there are some exceptions such as congenital neuroblastoma and hepatoblastoma. These tumours have a tendency to regress and have a benign clinical course despite a clear malignant histological picture. Other tumours, though histologically benign, may be fatal because of their size and location. Large benign masses may cause airway or cardiovascular compromise and death. Others may cause significant mass effect preventing normal organ development. As normal embryonic cells have a high mitotic rate it is not surprising that perinatal tumours may have a rapid growth rate and become enormous in size. (orig.)

  6. The impact of nodal tumour burden on lymphoscintigraphic imaging in patients with melanomas

    Energy Technology Data Exchange (ETDEWEB)

    Kretschmer, Lutz; Bertsch, Hans Peter; Hellriegel, Simin; Thoms, Kai-Martin; Schoen, Michael Peter [Georg August University of Goettingen, Department of Dermatology, Venereology and Allergology, Goettingen (Germany); Bardzik, Pawel; Meller, Johannes; Sahlmann, Carsten Oliver [Georg-August-University of Goettingen, Department of Nuclear Medicine, Goettingen (Germany)

    2014-10-15

    To retrospectively study the influence of nodal tumour burden on lymphoscintigraphic imaging in 509 consecutive patients with melanomas. Bidirectional lymphatic drainage, the clear depiction of an afferent lymphatic vessel, time to depiction of the first sentinel lymph node (SLN) and number of depicted and excised nodes were recorded. Nodal tumour load was classified as SLN-negative, SLN micrometastases or macrometastases. In the overall population, using multivariate regression analysis, a short SLN depiction time was significantly associated with the depiction of a greater number of radioactive nodes, a short distance between the primary tumour site and the nodal basin, younger age and lower nodal tumour burden. The proportion of patients with clear depiction of an afferent lymphatic vessel depended on the nodal tumour load (46 % in SLN-negative patients, 57 % in SLN positive patients, and 69 % in patients with macrometastases; P = 0.009). Macrometastasis was significantly associated with delayed depiction of the first radioactive node and a greater number of depicted hotspots. In patients with clinically nonsuspicious nodes, i.e. the classical target group for SLN biopsy, clear depiction of an afferent vessel was significantly associated with a higher number of SLNs during dynamic acquisition, SLN micrometastasis and a higher overall number of metastatic lymph nodes after SLN biopsy plus completion lymphadenectomy. The excision of more than two SLNs did not increase the metastasis detection rate. In patients with bidirectional or tridirectional lymphatic drainage, the SLN positivity rates for the first, second and third basin were 25.4 %, 11.7 % and 0.0 %, respectively (P = 0.002). In patients with clinically nonsuspicious lymph nodes, clear depiction of an afferent lymph vessel may be a sign of micrometastasis. Macrometastasis is associated with prominent afferent vessels, delayed depiction of the first radioactive node and a higher number of depicted hotspots

  7. Neonatal testicular tumour presenting as an acute scrotum ...

    African Journals Online (AJOL)

    Juvenile granulosa cell tumour (JGCT) is a rare benign stromal cell tumour of the testis accounting for approximately 1% of all paediatric testicular tumours. Presenting primarily as a painless testicular mass, the tumour may be associated with undescended testis, hydrocele or testicular torsion. Abnormal karyotype has also ...

  8. Neonatal testicular tumour presenting as an acute scrotum

    African Journals Online (AJOL)

    Neonatal testicular tumour presenting as an acute scrotum. Joyce M. Muhlschlegel, Alice L. Mears and Rowena J. Hitchcock. Juvenile granulosa cell tumour (JGCT) is a rare benign stromal cell tumour of the testis accounting for approximately 1% of all paediatric testicular tumours. Presenting primarily as a painless ...

  9. The effects of radiotherapy treatment uncertainties on the delivered dose distribution and tumour control probability

    International Nuclear Information System (INIS)

    Booth, J.T.; Zavgorodni, S.F.; Royal Adelaide Hospital, SA

    2001-01-01

    Uncertainty in the precise quantity of radiation dose delivered to tumours in external beam radiotherapy is present due to many factors, and can result in either spatially uniform (Gaussian) or spatially non-uniform dose errors. These dose errors are incorporated into the calculation of tumour control probability (TCP) and produce a distribution of possible TCP values over a population. We also study the effect of inter-patient cell sensitivity heterogeneity on the population distribution of patient TCPs. This study aims to investigate the relative importance of these three uncertainties (spatially uniform dose uncertainty, spatially non-uniform dose uncertainty, and inter-patient cell sensitivity heterogeneity) on the delivered dose and TCP distribution following a typical course of fractionated external beam radiotherapy. The dose distributions used for patient treatments are modelled in one dimension. Geometric positioning uncertainties during and before treatment are considered as shifts of a pre-calculated dose distribution. Following the simulation of a population of patients, distributions of dose across the patient population are used to calculate mean treatment dose, standard deviation in mean treatment dose, mean TCP, standard deviation in TCP, and TCP mode. These parameters are calculated with each of the three uncertainties included separately. The calculations show that the dose errors in the tumour volume are dominated by the spatially uniform component of dose uncertainty. This could be related to machine specific parameters, such as linear accelerator calibration. TCP calculation is affected dramatically by inter-patient variation in the cell sensitivity and to a lesser extent by the spatially uniform dose errors. The positioning errors with the 1.5 cm margins used cause dose uncertainty outside the tumour volume and have a small effect on mean treatment dose (in the tumour volume) and tumour control. Copyright (2001) Australasian College of

  10. Determination of tumour hypoxia with the PET tracer [{sup 18}F]EF3: improvement of the tumour-to-background ratio in a mouse tumour model

    Energy Technology Data Exchange (ETDEWEB)

    Christian, Nicolas; Bol, Anne; Bast, Marc de; Labar, Daniel; Lee, John; Mahy, Pierre; Gregoire, Vincent [Universite Catholique de Louvain, Center for Molecular Imaging and Experimental Radiotherapy, Brussels (Belgium)

    2007-09-15

    The 2-(2-nitroimidazol-1-yl)-N-(3,3,3-trifluoropropyl)acetamide (EF3) is a 2-nitroimidazole derivative which undergoes bioreductive activation under hypoxic conditions. Using the PET tracer [{sup 18}F]EF3 in mice, tumour-to-muscle ratios ranging from 1.3 to 3.5 were observed. This study investigated the impact of various interventions aimed at increasing [{sup 18}F]EF3 elimination, thus potentially increasing the tumour-to-noise ratio in mice, by increasing the renal filtration rate (spironolactone, furosemide), decreasing tubular re-absorption (metronidazole, ornidazole, amino acid solution) or stimulating gastro-intestinal elimination (phenobarbital). C3H mice were injected i.v. with an average of 12.95 MBq of [{sup 18}F]EF3. Drugs were injected i.v. 15 min before the tracer or daily 4 days prior to the experiment (phenobarbital). Anaesthetised mice were imaged from 30 to 300 min with a dedicated animal PET (Mosaic, Philips). Regions of interest were delineated around the tumour, bladder, heart, liver and leg muscle. Radioactivity was expressed as a percentage of injected activity per gram of tissue. Ornidazole decreased the urinary excretion and increased the liver uptake of [{sup 18}F]EF3, but without causing any changes in the other organs. Phenobarbital significantly increased the liver concentration and decreased radioactivity in blood and muscle without affecting the tracer uptake in tumour. Consequently, a small but non-significant increase in tumour-to-noise ratio was observed. Although some effects were observed with other drugs, they did not modify the tumour-to-noise ratio. Only phenobarbital induced a trend toward an increased tumour-to-noise ratio that could possibly be tested in the clinical situation. (orig.)

  11. Tumour regrowth after irradiation. An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Yamaura, H; Matsuzawa, T [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis, Leprosy and Cancer

    1979-03-01

    Structural changes in irradiated tumours and their regrowth were studied in a rat hepatoma, AH109A, using histological and transparent-chamber techniques. The development of the tumour was examined by means of vascular morphometry as observed in the chamber. Schematically, the tumour tissue was divided into four isocentric layers according to vascular morphology and measurements of vessel volume, surface area, and length per mm/sup 3/ of tissue. The vascularity was greatest in the outermost region, decreased towards the inner parts and reached an absence of vascularity at the central necrosis. The tumours were gamma- or X-irradiated with various doses. The inside hypoxic region was destroyed completely after 300 rad, and regrowths started exclusively from the outermost area of the tumour where enhancement of the effect of radiation by oxygen was thought to be greatest. Possible mechanisms of tumour regrowth are discussed.

  12. Tumour-induced osteomalacia: An emergent paraneoplastic syndrome.

    Science.gov (United States)

    Alonso, Guillermo; Varsavsky, Mariela

    2016-04-01

    Endocrine paraneoplastic syndromes are distant manifestations of some tumours. An uncommon but increasingly reported form is tumour-induced osteomalacia, a hypophosphatemic disorder associated to fibroblast growth factor 23 (FGF-23) secretion by tumours. The main biochemical manifestations of this disorder include hypophosphatemia, inappropriately low or normal tubular reabsorption of phosphate, low serum calcitriol levels, increased serum alkaline phosphatase levels, and elevated or normal serum FGF-23 levels. These tumours, usually small, benign, slow growing and difficult to discover, are mainly localized in soft tissues of the limbs. Histologically, phosphaturic mesenchymal tumours of the mixed connective tissue type are most common. Various imaging techniques have been suggested with variable results. Treatment of choice is total surgical resection of the tumour. Medical treatment includes oral phosphorus and calcitriol supplements, octreotide, cinacalcet, and monoclonal antibodies. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  13. Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy

    Science.gov (United States)

    Zhang, Yawei; Yin, Fang-Fang; Zhang, You; Ren, Lei

    2017-05-01

    The purpose of this study is to develop an adaptive prior knowledge guided image estimation technique to reduce the scan angle needed in the limited-angle intrafraction verification (LIVE) system for 4D-CBCT reconstruction. The LIVE system has been previously developed to reconstruct 4D volumetric images on-the-fly during arc treatment for intrafraction target verification and dose calculation. In this study, we developed an adaptive constrained free-form deformation reconstruction technique in LIVE to further reduce the scanning angle needed to reconstruct the 4D-CBCT images for faster intrafraction verification. This technique uses free form deformation with energy minimization to deform prior images to estimate 4D-CBCT based on kV-MV projections acquired in extremely limited angle (orthogonal 3°) during the treatment. Note that the prior images are adaptively updated using the latest CBCT images reconstructed by LIVE during treatment to utilize the continuity of the respiratory motion. The 4D digital extended-cardiac-torso (XCAT) phantom and a CIRS 008A dynamic thoracic phantom were used to evaluate the effectiveness of this technique. The reconstruction accuracy of the technique was evaluated by calculating both the center-of-mass-shift (COMS) and 3D volume-percentage-difference (VPD) of the tumor in reconstructed images and the true on-board images. The performance of the technique was also assessed with varied breathing signals against scanning angle, lesion size, lesion location, projection sampling interval, and scanning direction. In the XCAT study, using orthogonal-view of 3° kV and portal MV projections, this technique achieved an average tumor COMS/VPD of 0.4  ±  0.1 mm/5.5  ±  2.2%, 0.6  ±  0.3 mm/7.2  ±  2.8%, 0.5  ±  0.2 mm/7.1  ±  2.6%, 0.6  ±  0.2 mm/8.3  ±  2.4%, for baseline drift, amplitude variation, phase shift, and patient breathing signal variation

  14. Concomitant expression of several peptide receptors in neuroendocrine tumours: molecular basis for in vivo multireceptor tumour targeting

    Energy Technology Data Exchange (ETDEWEB)

    Reubi, Jean Claude; Waser, Beatrice [Division of Cell Biology and Experimental Cancer Research, Institute of Pathology, University of Berne, Murtenstrasse 31, PO Box 62, 3010, Berne (Switzerland)

    2003-05-01

    Peptide receptors have been found to represent excellent targets for in vivo cancer diagnosis and therapy. Recent in vitro studies have shown that many cancers can overexpress not only one but several peptide receptors concomitantly. One of the challenges for nuclear medicine in this field in the coming decade will be to take advantage of the co-expression of peptide receptors for multireceptor tumour targeting. In vitro receptor studies can reveal which peptide receptor is overexpressed in which tumour and which receptors are co-expressed in an individual tumour; such knowledge is a prerequisite for successful in vivo development. One group of tumours of particular interest in this respect is the neuroendocrine tumours, which have previously been shown often to express peptide receptors. This review summarises our investigations of the concomitant expression of 13 different peptide receptors, in more than 100 neuroendocrine tumours of the human intestine, pancreas and lung, using in vitro receptor autoradiography with subtype-selective ligands. The incidence and density of the somatostatin receptors sst{sub 1}-sst{sub 5}, the VIP receptors VPAC{sub 1} and VPAC{sub 2}, the CCK{sub 1} and CCK{sub 2} receptors, the three bombesin receptor subtypes BB{sub 1} (NMB receptor), BB{sub 2} (GRP receptor) and BB{sub 3}, and GLP-1 receptors were evaluated. While the presence of VPAC{sub 1} and sst{sub 2} was detected in the majority of these neuroendocrine tumours, the other receptors, more differentially expressed, revealed a characteristic receptor pattern in several tumour types. Ileal carcinoids expressed sst{sub 2} and VPAC{sub 1} receptors in virtually all cases and had CCK{sub 1}, CCK{sub 2}, sst{sub 1} or sst{sub 5} in approximately half of the cases; they were the only tumours of this series to express NMB receptors. Insulinomas were characterised by a very high incidence of GLP-1, CCK{sub 2} and VPAC{sub 1} receptors, with the GLP-1 receptors expressed in a

  15. CYP3A isoforms in Ewing's sarcoma tumours: an immunohistochemical study with clinical correlation.

    Science.gov (United States)

    Zia, Hamid; Murray, Graeme I; Vyhlidal, Carrie A; Leeder, J Steven; Anwar, Ahmed E; Bui, Marilyn M; Ahmed, Atif A

    2015-04-01

    Ewing's sarcoma is an aggressive malignancy of bone and soft tissue with high incidence of metastasis and resistance to chemotherapy. Cytochrome P450 (CYP) monooxygenases are a family of enzymes that are involved in the metabolism of exogenous and endogenous compounds, including anti-cancer drugs, and have been implicated in the aggressive behaviour of various malignancies. Tumour samples and clinical information including age, sex, tumour site, tumour size, clinical stage and survival were collected from 36 adult and paediatric patients with Ewing's sarcoma family tumours. Tissue microarrays slides were processed for immunohistochemical labelling for CYP3A4, CYP3A5 and CYP3A7 using liver sections as positive control. The intensity of staining was scored as negative, low or high expression and was analysed statistically for any association with patients' clinical information. Four cases were later excluded due to inadequate viable tissue. CYP3A4 staining was present in 26 (81%) cases with high expression noted in 13 (40%) of 32 cases. High expression was significantly associated with distant metastases (P Ewing's sarcoma tumours and high CYP3A4 expression may be associated with metastasis. Additional studies are needed to further investigate the role of CYP3A4 in the prognosis of these tumours. © 2015 The Authors. International Journal of Experimental Pathology © 2015 International Journal of Experimental Pathology.

  16. Tumour screening by means of tomography methods

    International Nuclear Information System (INIS)

    Diederich, S.

    2005-01-01

    Tomography methods such as computer tomography (CT), magnetic resonance tomography (MRT), and sonography/ultrasound examinations make it possible to detect small asymptomatic tumours, thus potentially preventing their manifestation at an advanced stage and improving survival prospects for the patients concerned. There are data available on various common tumours which show that modern tomography methods are capable of detecting not only small asymptomatic tumours but also their benign precursors (e.g. polyps of the large intestine). This has been demonstrated for lung cancer, colon cancer and breast cancer. However, it has not been possible to date to show for any tomography method or any type of tumour that the systematic use of such diagnostic procedures does anything to lower the mortality rate for that tumour. For other types of tumour (pancreatic cancer, kidney cancer, ovary cancer) the above named methods are either not sufficiently sensitive or the body of data that has accumulated on their respective use is too small to judge the benefit of tomography screenings. Current technical developments make it appear probable that for many types of cancer the reliability with which small tumours can be detected will improve in future. Studies aimed at clarifying the potential of screenings for reducing mortality rates are already underway for lung cancer and would be worthwhile performing for other tumour types

  17. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes.

    Science.gov (United States)

    Bjerre, Troels; Crijns, Sjoerd; af Rosenschöld, Per Munck; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul

    2013-07-21

    The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.

  18. Elevated EGF Levels in the Blood Serum of Dogs with Periodontal Diseases and Oral Tumours.

    Science.gov (United States)

    Sobczyńska-Rak, Aleksandra; Żylińska, Beata; Polkowska, Izabela; Szponder, Tomasz

    2018-01-01

    Paradontopathy and neoplasms of the oral cavity represent one of the greatest challenges in human and animal dentistry. EGF plays a key role in maintaining the integrity and proper rate of cell proliferation in normal oral epithelium. The aim of the present study was to study serum levels of EGF in dogs diagnosed with periodontal diseases and oral cavity tumours. The samples comprised of cancerous tissue sections and serum obtained from dogs of various breeds, aged between 5-13 years. Serum EGF concentrations were measured by an immunoenzymatic method. The median for EGF concentration in serum of dogs suffered from severe periodontal diseases was greater when compared to the control group. EGF concentration in dogs with malignant tumours was significantly higher than in those with non-malignant growths. A positive correlation between EGF concentration and tumour size was also observed. EGF level in dogs diagnosed with benign tumours was comparable to the control group. The blood serum level of EGF increases significantly in patients with malignant oral tumours and advanced periodontal disease. In malignant tumours, the high level of EGF correlates with the size and invasiveness of the neoplasm. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Histopathological features of breast tumours in BRCA1, BRCA2 and mutation-negative breast cancer families

    International Nuclear Information System (INIS)

    Eerola, Hannaleena; Heikkilä, Päivi; Tamminen, Anitta; Aittomäki, Kristiina; Blomqvist, Carl; Nevanlinna, Heli

    2005-01-01

    Histopathological features of BRCA1 and BRCA2 tumours have previously been characterised and compared with unselected breast tumours; however, familial non-BRCA1/2 tumours are less well known. The aim of this study was to characterise familial non-BRCA1/2 tumours and to evaluate routine immunohistochemical and pathological markers that could help us to further distinguish families carrying BRCA1/2 mutations from other breast cancer families. Breast cancer tissue specimens (n = 262) from 25 BRCA1, 20 BRCA2 and 74 non-BRCA1/2 families were studied on a tumour tissue microarray. Immunohistochemical staining of oestrogen receptor (ER), progesterone receptor (PgR) and p53 as well as the histology and grade of these three groups were compared with each other and with the respective information on 862 unselected control patients from the archives of the Pathology Department of Helsinki University Central Hospital. Immunohistochemical staining of erbB2 was also performed among familial cases. BRCA1-associated cancers were diagnosed younger and were more ER-negative and PgR-negative, p53-positive and of higher grade than the other tumours. However, in multivariate analysis the independent factors compared with non-BRCA1/2 tumours were age, grade and PgR negativity. BRCA2 cases did not have such distinctive features compared with non-BRCA1/2 tumours or with unselected control tumours. Familial cases without BRCA1/2 mutations had tumours of lower grade than the other groups. BRCA1 families differed from mutation-negative families by age, grade and PgR status, whereas ER status was not an independent marker

  20. Phase congruency map driven brain tumour segmentation

    Science.gov (United States)

    Szilágyi, Tünde; Brady, Michael; Berényi, Ervin

    2015-03-01

    Computer Aided Diagnostic (CAD) systems are already of proven value in healthcare, especially for surgical planning, nevertheless much remains to be done. Gliomas are the most common brain tumours (70%) in adults, with a survival time of just 2-3 months if detected at WHO grades III or higher. Such tumours are extremely variable, necessitating multi-modal Magnetic Resonance Images (MRI). The use of Gadolinium-based contrast agents is only relevant at later stages of the disease where it highlights the enhancing rim of the tumour. Currently, there is no single accepted method that can be used as a reference. There are three main challenges with such images: to decide whether there is tumour present and is so localize it; to construct a mask that separates healthy and diseased tissue; and to differentiate between the tumour core and the surrounding oedema. This paper presents two contributions. First, we develop tumour seed selection based on multiscale multi-modal texture feature vectors. Second, we develop a method based on a local phase congruency based feature map to drive level-set segmentation. The segmentations achieved with our method are more accurate than previously presented methods, particularly for challenging low grade tumours.

  1. Classification of breast tumour using electrical impedance and machine learning techniques.

    Science.gov (United States)

    Al Amin, Abdullah; Parvin, Shahnaj; Kadir, M A; Tahmid, Tasmia; Alam, S Kaisar; Siddique-e Rabbani, K

    2014-06-01

    When a breast lump is detected through palpation, mammography or ultrasonography, the final test for characterization of the tumour, whether it is malignant or benign, is biopsy. This is invasive and carries hazards associated with any surgical procedures. The present work was undertaken to study the feasibility for such characterization using non-invasive electrical impedance measurements and machine learning techniques. Because of changes in cell morphology of malignant and benign tumours, changes are expected in impedance at a fixed frequency, and versus frequency of measurement. Tetrapolar impedance measurement (TPIM) using four electrodes at the corners of a square region of sides 4 cm was used for zone localization. Data of impedance in two orthogonal directions, measured at 5 and 200 kHz from 19 subjects, and their respective slopes with frequency were subjected to machine learning procedures through the use of feature plots. These patients had single or multiple tumours of various types in one or both breasts, and four of them had malignant tumours, as diagnosed by core biopsy. Although size and depth of the tumours are expected to affect the measurements, this preliminary work ignored these effects. Selecting 12 features from the above measurements, feature plots were drawn for the 19 patients, which displayed considerable overlap between malignant and benign cases. However, based on observed qualitative trend of the measured values, when all the feature values were divided by respective ages, the two types of tumours separated out reasonably well. Using K-NN classification method the results obtained are, positive prediction value: 60%, negative prediction value: 93%, sensitivity: 75%, specificity: 87% and efficacy: 84%, which are very good for such a test on a small sample size. Study on a larger sample is expected to give confidence in this technique, and further improvement of the technique may have the ability to replace biopsy.

  2. Classification of breast tumour using electrical impedance and machine learning techniques

    International Nuclear Information System (INIS)

    Amin, Abdullah Al; Parvin, Shahnaj; Kadir, M A; Tahmid, Tasmia; Alam, S Kaisar; Siddique-e Rabbani, K

    2014-01-01

    When a breast lump is detected through palpation, mammography or ultrasonography, the final test for characterization of the tumour, whether it is malignant or benign, is biopsy. This is invasive and carries hazards associated with any surgical procedures. The present work was undertaken to study the feasibility for such characterization using non-invasive electrical impedance measurements and machine learning techniques. Because of changes in cell morphology of malignant and benign tumours, changes are expected in impedance at a fixed frequency, and versus frequency of measurement. Tetrapolar impedance measurement (TPIM) using four electrodes at the corners of a square region of sides 4 cm was used for zone localization. Data of impedance in two orthogonal directions, measured at 5 and 200 kHz from 19 subjects, and their respective slopes with frequency were subjected to machine learning procedures through the use of feature plots. These patients had single or multiple tumours of various types in one or both breasts, and four of them had malignant tumours, as diagnosed by core biopsy. Although size and depth of the tumours are expected to affect the measurements, this preliminary work ignored these effects. Selecting 12 features from the above measurements, feature plots were drawn for the 19 patients, which displayed considerable overlap between malignant and benign cases. However, based on observed qualitative trend of the measured values, when all the feature values were divided by respective ages, the two types of tumours separated out reasonably well. Using K-NN classification method the results obtained are, positive prediction value: 60%, negative prediction value: 93%, sensitivity: 75%, specificity: 87% and efficacy: 84%, which are very good for such a test on a small sample size. Study on a larger sample is expected to give confidence in this technique, and further improvement of the technique may have the ability to replace biopsy. (paper)

  3. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 11: Quantification of chest wall motion during deep inspiration breast hold treatments using cine EPID images and a physics based algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Alpuche Aviles, Jorge E.; VanBeek, Timothy [CancerCare Manitoba, Winnipeg (Canada); Sasaki, David; Rivest, Ryan; Akra, Mohamed [CancerCare Manitoba, Winnipeg (Canada); University of Manitoba, Winnipeg (Canada)

    2016-08-15

    Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portal images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.

  4. Breast tumours of adolescents in an African population

    Directory of Open Access Journals (Sweden)

    Umanah Ivy

    2010-01-01

    Full Text Available Background: Tumours of the breast are uncommon in childhood and adolescence. Patients in this age group often require a different approach to diagnosis and treatment. The purpose of this study is to highlight the clinicopathologic features of breast tumours in adolescents in a Nigerian city. Materials and Methods: Eighty-four breast tumour materials from patients aged 10-19 years were analyzed over a 10-year period at the Department of Pathology, University of Benin Teaching Hospital (UBTH, Benin City, Edo State, Benin City, Nigeria. Results: A majority of the breast tumours were benign. Fibroadenoma was the most common tumour with 46 cases (54.8%, followed by fibrocystic changes with 15 cases (17%. Malignancy was extremely rare in this group, with only one case (1.2% of an invasive ductal carcinoma. Histologically, most tumours were indistinguishable from the adult types. Conclusion: Fibroadenoma is the most common breast tumour in adolescents in Benin City, Nigeria. Breast cancer and male breast tumours are rare in this age group. Routine complete physical examination of children and adolescents should include breast examination.

  5. Imaging in unilateral Wilms tumour

    International Nuclear Information System (INIS)

    Brisse, Herve J.; Smets, Anne M.; Kaste, Sue C.; Owens, Catherine M.

    2008-01-01

    Wilms tumour is one of the most common malignancies in children, with an excellent prognosis after therapy. There is a very diverse approach to treatment according to geographical location. This variation in therapeutic attitude toward Wilms tumour, particularly between the United States and Europe, has consequences for the choice of imaging modality at diagnosis. In Europe, the International Society of Paediatric Oncology (SIOP) treatment protocol is based on chemotherapy followed by surgery. Imaging (US, CT and MRI), clinical history and examination will help predict whether the findings are consistent with Wilms tumour. Furthermore, in the UK preoperative image-guided biopsy is advised to help identify the small group of patients who, despite typical imaging features of Wilms tumour, have other types of neoplasia that require alternative management. In the United States, the National Wilms Tumor Study (NWTS) advises surgery prior to chemo- and radiotherapy. Hence imaging must provide detailed anatomical information for surgical planning. This article discusses the role of imaging at diagnosis and the relative strengths and weaknesses of the available radiological techniques. We also focus on imaging the lung for metastatic disease and the consequences (to the patient's ultimate outcome) of CT-diagnosed small pulmonary nodules and discuss the radiological diagnosis and consequences of tumour rupture present at diagnosis. (orig.)

  6. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [{sup 18}F]-fluoroethyltyrosine (FET) PET/MRI: feasibility, agreement and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Otto M.; Hansen, Adam E.; Law, Ian [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Clinical Physiology Nuclear Medicine and PET, Copenhagen (Denmark); Larsen, Vibeke A. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Radiology, Copenhagen (Denmark); Muhic, Aida; Poulsen, Hans S. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Oncology, Copenhagen (Denmark); Larsson, Henrik B.W. [Copenhagen University Hospital Rigshospitalet Glostrup, Functional Imaging Unit, Department of Clinical Physiology Nuclear Medicine and PET, Glostrup (Denmark)

    2016-01-15

    Both [{sup 18}F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens mMR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBR{sub max}) and BV (rBV{sub max}), and Dice coefficients were calculated to assess the quantitative and spatial congruence in the tumour volumes determined by FET PET, BV MRI and contrast-enhanced MRI. FET volume and TBR{sub max} were higher in BV-positive than in BV-negative scans, and both VOL{sub BV} and rBV{sub max} were higher in FET-positive than in FET-negative scans. TBR{sub max} and rBV{sub max} were positively correlated (R{sup 2} = 0.59, p < 0.001). FET and BV positivity were in agreement in only 26 of the 32 patients and in 42 of 63 lesions, and spatial congruence in the tumour volumes as assessed by the Dice coefficients was generally poor with median Dice coefficients exceeding 0.1 in less than half the patients positive on at least one modality for any pair of modalities. In 56 % of the patients susceptibility artefacts in DSC BV maps overlapped the tumour on MRI. The study demonstrated that although tumour volumes determined by BV MRI and FET PET were quantitatively correlated, their spatial congruence in a mixed population of treated glioma patients was generally poor, and the modalities did not provide the same information in this population of patients. Combined

  7. Development of a real-time monitoring system for intra-fractional motion in intracranial treatment using pressure sensors.

    Science.gov (United States)

    Inata, Hiroki; Araki, Fujio; Kuribayashi, Yuta; Hamamoto, Yasushi; Nakayama, Shigeki; Sodeoka, Noritaka; Kiriyama, Tetsukazu; Nishizaki, Osamu

    2015-09-21

    This study developed a dedicated real-time monitoring system to detect intra-fractional head motion in intracranial radiotherapy using pressure sensors. The dedicated real-time monitoring system consists of pressure sensors with a thickness of 0.6 mm and a radius of 9.1 mm, a thermoplastic mask, a vacuum pillow, and a baseplate. The four sensors were positioned at superior-inferior and right-left sides under the occipital area. The sampling rate of pressure sensors was set to 5 Hz. First, we confirmed that the relationship between the force and the displacement of the vacuum pillow follows Hook's law. Next, the spring constant for the vacuum pillow was determined from the relationship between the force given to the vacuum pillow and the displacement of the head, detected by Cyberknife target locating system (TLS) acquisitions in clinical application. Finally, the accuracy of our system was evaluated by using the 2  ×  2 confusion matrix. The regression lines between the force, y, and the displacement, x, of the vacuum pillow were given by y = 3.8x, y = 4.4x, and y = 5.0x when the degree of inner pressure was  -12 kPa,-20 kPa, and  -27 kPa, respectively. The spring constant of the vacuum pillow was 1.6 N mm(-1) from the 6D positioning data of a total of 2999 TLS acquisitions in 19 patients. Head motions of 1 mm, 1.5 mm, and 2 mm were detected in real-time with the accuracies of 67%, 84%, and 89%, respectively. Our system can detect displacement of the head continuously during every interval of TLS with a resolution of 1-2 mm without any radiation exposure.

  8. Modelling of tumour repopulation after chemotherapy

    International Nuclear Information System (INIS)

    Marcu, Loredana; Bezak, Eva

    2010-01-01

    Full text: While repopulation is a clinically observed phe nomenon after radiotherapy, repopulation of tumour cells between cycles of chemotherapy is usually a neglected factor in cancer treatment. As the effect of both radiotherapy and chemotherapy on tumour cells is the same (attack on cancer cells), the response of the tumour to injury and cell loss from the two treatment methods should be similar, including repopulation. Cell recruitment is known to be a possible mechanism responsible for tumour regrowth after radio therapy. The literature data regarding mechanisms of repopulation after chemotherapy is very limited. The current paper employs a Monte Carlo modelling approach to implement the pharmacokinetics of a widely used drug (cisplatin) into a previously developed vit1ual head and neck tumour and to study the effect of cisplatin on tumour regres sion and regrowth during treatment. The mechanism of cell recruitment was modelled by releasing various percentages (5-50%) of quiescent cells into the mitotic cycle after each chemotherapy cell kill. The onset of repopulation was also simulated, with both immediate onset and late onset of cell recruitment. Repopulation during chemotherapy, if occu ring, is a highly potent phenomenon, similar to drug resis tance, therefore it should not be neglected during treatment.

  9. EVALUATION OF BRAIN TUMOURS USING COMPUTED TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    B. Vinod Kumar

    2016-07-01

    Full Text Available BACKGROUND The brain is basically formed by the neurons and the supporting cells. Tumours arising of neurons are almost impossible because the neurons never divide. Tumours arising from the supporting cells are almost frequently seen. The tumour characteristics depend upon the cell of origin. The brain is covered by meninges and the vascular tissue supplies the essential nutrients to all these components of the brain. Unfortunately, the brain is placed in a rigid box called as neurocranium. According to Monro–Kellie principle, if any of the one component increases in a rigid box, the other components will be compensated. So in a limited space if any of the catastrophes occur i.e. space occupying lesions, then the other components will be compensated and as a result the effects will be seen in a very small amount of time. A sincere effort has been put in this study to understand and evaluate the Brain Tumours using a CT scan. This study is intended to be useful to the diagnosing radiologists, internal medicine practitioners and general practitioners and surgeons. METHODS The aim of the study is to evaluate the brain tumours using CT and to confirm the diagnosis by sending to the Histopathology Department. The study is a cross-sectional study and is done in the Department of Radiology, Fathima Medical College, Kadapa, Andhra Pradesh. The study was done from December 2014 to May 2016. The study was done using thirty cases who were believed to have brain tumour and were studied in the Department of Radiology after initial clinical evaluation. First, the plain CT was done and was checked for the location, size, characteristics of the lesion and the surrounding characteristics were observed. RESULT In the present study, the most common of all tumours were those of the neuroepithelial groups. Next in frequency were the tumours of meninges of all intracranial tumours. This was followed by tumours of cranial nerves, metastatic tumour, one lymphoma case

  10. Molecular pathology of bone tumours: diagnostic implications.

    Science.gov (United States)

    Puls, Florian; Niblett, Angela J; Mangham, D Chas

    2014-03-01

    Alongside histomorphology and immunohistochemistry, molecular pathology is now established as one of the cornerstones in the tissue diagnosis of bone tumours. We describe the principal molecular pathological techniques employed, and each of the bone tumour entities where their identified characteristic molecular pathological changes can be detected to support and confirm the suspected histological diagnosis. Tumours discussed include fibrous dysplasia, classical and subtype osteosarcomas, central and surface cartilaginous tumours, Ewing's sarcoma, vascular tumours, aneurysmal bone cyst, chordoma, myoepithelioma, and angiomatoid fibrous histiocytoma. This is a rapidly evolving field with discoveries occurring every few months, and some of the newer entities (the Ewing's-like sarcomas), which are principally identified by their molecular pathology characteristics, are discussed. © 2013 John Wiley & Sons Ltd.

  11. Diffusion-weighted imaging in the evaluation of odontogenic cysts and tumours.

    Science.gov (United States)

    Srinivasan, K; Seith Bhalla, A; Sharma, R; Kumar, A; Roychoudhury, A; Bhutia, O

    2012-10-01

    The differentiation between keratocystic odontogenic tumour (KCOT) and other cystic/predominantly cystic odontogenic tumours is difficult on conventional CT and MR sequences as there is overlap in the imaging characteristics of these lesions. The purpose of this study was to evaluate the role of diffusion-weighted imaging (DWI) and to assess the performance of apparent diffusion coefficients (ADCs) in the differential diagnosis of odontogenic cysts and tumours. 20 patients with odontogenic cysts and tumours of the maxillomandibular region were examined with DWI. Diffusion-weighted images were obtained with a single-shot echoplanar technique with b-values of 0, 500 and 1000 s mm(-2). An ADC map was obtained at each slice position. The cystic areas of ameloblastoma (n=10) showed free diffusion with a mean ADC value of 2.192±0.33×10(-3) mm(2) s(-1), whereas the solid areas showed restricted diffusion with a mean ADC value of 1.041±0.41×10(-3) mm(2) s(-1). KCOT (n=5) showed restricted diffusion with a mean ADC value of 1.019±0.07×10(-3) mm(2) s(-1). There was a significant difference between the ADC values of KCOT and cystic ameloblastoma (p<0.01, Mann-Whitney U-test). The cut-off with which KCOT and predominantly cystic ameloblastomas were optimally differentiated was 2.013×10(-3) mm(2) s(-1), which yielded 100% sensitivity and 100% specificity. DWI can be used to differentiate KCOT from cystic (or predominantly cystic) odontogenic tumours.

  12. [Glomus tumour of the lung: a case report and literature review].

    Science.gov (United States)

    Baena-Del Valle, Javier Alonso; Murillo-Echeverri, Victoria Eugenia; Gaviria-Velásquez, Alejandro; Celis-Mejía, Diego Miguel; Matute-Turizo, Gustavo

    2015-01-01

    Glomus tumours are neoplasms arising from cells of the neuromyoarterial glomus bodies, which almost always occur in a subungual location. A lung location is extremely rare, with few cases reported in the literature. The case is presented of a 33 year-old male, with non-productive cough, dyspnoea at rest, intermittent fever, and mild pain in rib cage. A chest radiograph showed a consolidation in the left lung, and computed tomography revealed a lesion in the hilum that extended to the bronchus of the lingula obstructing, and causing post-obstructive pneumonia. A biopsy was obtained by rigid bronchoscopy biopsy, which showed a well circumscribed tumour constituted by intermediate-sized cells, and abundant cytoplasm that are arranged in a pattern surrounding numerous thin-walled blood vessels, with no pleomorphism, significant mitotic activity or necrosis. Immunohistochemistry revealed diffuse positivity with smooth muscle actin, vimentin, caldesmon; focal reactivity with desmin and CD117, CD34 highlights the vascular pattern. Ki67 proliferation rate was 1%. Synaptophysin, EMA and cytokeratin cocktail were negative, making the diagnosis of glomus tumour. Glomus tumours are rare neoplasms that usually appear in the dermis and subcutaneous tissue, where it is common to find glomus bodies. Occasionally glomus tumours can occur in extra-cutaneous sites such as the gastrointestinal tract, bone and respiratory system, with this case being a new case of rare lung location. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  13. Anti-tumour therapeutic efficacy of OX40L in murine tumour model.

    Science.gov (United States)

    Ali, Selman A; Ahmad, Murrium; Lynam, June; McLean, Cornelia S; Entwisle, Claire; Loudon, Peter; Choolun, Esther; McArdle, Stephanie E B; Li, Geng; Mian, Shahid; Rees, Robert C

    2004-09-09

    OX40 ligand (OX40L), a member of TNF superfamily, is a co-stimulatory molecule involved in T cell activation. Systemic administration of mOX40L fusion protein significantly inhibited the growth of experimental lung metastasis and subcutaneous (s.c.) established colon (CT26) and breast (4T1) carcinomas. Vaccination with OX40L was significantly enhanced by combination treatment with intra-tumour injection of a disabled infectious single cycle-herpes simplex virus (DISC-HSV) vector encoding murine granulocyte macrophage-colony stimulating factor (mGM-CSF). Tumour rejection in response to OX40L therapy required functional CD4+ and CD8+ T cells and correlated with splenocyte cytotoxic T lymphocytes (CTLs) activity against the AH-1 gp70 peptide of the tumour associated antigen expressed by CT26 cells. These results demonstrate the potential role of the OX40L in cancer immunotherapy.

  14. Diagnosis of bladder tumours in patients with macroscopic haematuria

    DEFF Research Database (Denmark)

    Gandrup, Karen L; Løgager, Vibeke B; Bretlau, Thomas

    2015-01-01

    patients underwent CTU, MRU and flexible cystoscopy. Two uroradiologists individually reviewed the images without any clinical information, using a questionnaire. Patient records and pathology reports were also reviewed. RESULTS: At flexible cystoscopy, MRU and CTU, 32, 19 and 15 bladder lesions were...... identified, respectively. Histopathology showed that 13 of the 29 biopsied lesions were transitional cell carcinomas. Compared with the histopathology, the sensitivity and specificity for detection of tumours by CTU and MRU were 61.5% and 94.9%, and 79.9% and 93.4%, respectively. False-positive detection...... of bladder tumours, compared with histopathology, was reported in seven CTUs and nine MRUs, whereas the number of false-negative findings was five for CTUs and three for MRUs. CONCLUSIONS: Split-bolus CTU or MRU cannot replace cystoscopy in cases of macroscopic haematuria. MRU has a higher sensitivity than...

  15. Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

    International Nuclear Information System (INIS)

    Takao, Seishin; Miyamoto, Naoki; Matsuura, Taeko; Onimaru, Rikiya; Katoh, Norio; Inoue, Tetsuya; Sutherland, Kenneth Lee; Suzuki, Ryusuke; Shirato, Hiroki; Shimizu, Shinichi

    2016-01-01

    Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

  16. Lack of relationship between TIMP-1 tumour cell immunoreactivity, treatment efficacy and prognosis in patients with advanced epithelial ovarian cancer

    International Nuclear Information System (INIS)

    Steffensen, Karina Dahl; Waldstrøm, Marianne; Christensen, Rikke Kølby; Bartels, Annette; Brünner, Nils; Jakobsen, Anders

    2010-01-01

    Tissue inhibitor of metalloproteinase 1 (TIMP-1) is a natural inhibitor of the matrix metalloproteinases (MMPs) which are proteolytic enzymes involved in degradation of extracellular matrix thereby favoring tumour cell invasion and metastasis. TIMP-1 activity in tumour tissue may therefore play an essential role in the progression of a malignant tumour. The primary aim of the present study was to evaluate TIMP-1 protein immunoreactivity in tissue from primary ovarian cancer patients and associate these findings with the course of the disease including response to treatment in the individual patient. TIMP-1 was assessed by immunohistochemistry (in tissue micro arrays) in a total of 163 ovarian cancer specimens obtained from primary debulking surgery during 1991-1994 as part of a randomized clinical protocol. Positive TIMP-1 immunoreactivity was found in 12.3% of the tumours. The median survival time for the 143 patients with TIMP-1 negative tumours was 23.7 months [19.0-29.4] 95% CI, while the median survival time for the 20 patients with TIMP-1 positive tumours was 15.9 months [12.3-27.4] 95% CI. Although a difference of 7.8 months in median overall survival in favor of the TIMP-1 tumour negative patients was found, this difference did not reach statistical significance (p = 0.28, Kaplan-Meier, log-rank test). Moreover, TIMP-1 immunoreactivity was not associated with CA125 response (p = 0.53) or response at second look surgery (p = 0.72). TIMP-1 immunoreactivity in tumour tissue from patients with primary epithelial ovarian cancer did not correlate with patient survival or response to combination platinum/cyclophosphamide therapy

  17. Fatty degeneration in a Wilms' tumour after chemotherapy

    International Nuclear Information System (INIS)

    Jeanes, A.C.; Beese, R.C.; McHugh, K.; Ramsay, A.D.

    2002-01-01

    We report a case of extensive fatty change in a Wilms' tumour after chemotherapy demonstrated on CT associated with an increase in tumour volume, in a 10-month-old girl with Beckwith-Wiedemann syndrome. Changes in tumour characteristics after chemotherapy on imaging usually reflect necrosis, haemorrhage and calcification. Assessment of response to therapy is dependent on a documented reduction in tumour volume. In this case, CT showed an increase in tumour size with development of an extensive fatty component following treatment. Subsequent histological examination on the nephrectomy specimen confirmed an extensive fatty component with no evidence of residual blastema. The development of such an extensive fatty component is very unusual. In this case such fatty change was an indicator of tumour sensitivity and response to treatment. (orig.)

  18. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Valli, Lorella [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Aluwini, Shafak [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Lanconelli, Nico [Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Heijmen, Ben; Hoogeman, Mischa [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands)

    2014-04-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3

  19. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    International Nuclear Information System (INIS)

    Water, Steven van de; Valli, Lorella; Aluwini, Shafak; Lanconelli, Nico; Heijmen, Ben; Hoogeman, Mischa

    2014-01-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V 100% ) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm

  20. Carcinoid Tumour of the Ovary

    African Journals Online (AJOL)

    Abstract. A case of bilateral carcinoid tumour of the ovary, with benign cystic teratoma in one ovary, in a 38 year old woman is presented. She had total abdominal hysterectomy, bilateral salpingoophorectomy, infracolic omentectomy and appendectomy. There was no macroscopic tumour in the vermiform appendix and the ...

  1. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  2. Radiation Effect on Secondary Cancerization by Tumour Cell Grafts. Take of Irradiated Tumour Cells in Irradiated and Non-Irradiated Animals

    Energy Technology Data Exchange (ETDEWEB)

    Costachel, O.; Sandru, Gh.; Kitzulescu, I. [Oncological Institute, Bucharest (Romania)

    1969-11-15

    This study was designed to determine the ability of haemocytoblastoma, SME and Jensen tumours, which had been irradiated in vitro, to take in C{sub 57}BL/6 mice or Wistar rats that were whole-body irradiated at 0.4 kR and 0.6 kR respectively. It was found-that the take of tumour cell grafts irradiated in vitro increased in whole-body irradiated mice and rats but not in non-irradiated ones. When Wistar rats, that had been whole-body irradiated with 0.7 and 0.8 kR 1 - 7 months earlier and survived after treatment, were grafted with Jensen tumour cells irradiated in vitro with 3 kR they were found to develop tumours and lung metastases (in contrast to non-irradiated rats). A cross resistance against non-irradiated Jensen tumour cells was obtained in non- irradiated Wistar rats by grafting irradiated Jensen tumour cells. Chromosomal analysis showed two supplementary giant markers in the Jensen tumour cells that had been irradiated in vitro before grafting. (author)

  3. Analysis of clonogenic human brain tumour cells: preliminary results of tumour sensitivity testing with BCNU

    Energy Technology Data Exchange (ETDEWEB)

    Rosenblum, M L; Dougherty, D A; Deen, D F; Hoshino, T; Wilson, C B [California Univ., San Francisco (USA). Dept. of Neurology

    1980-04-01

    Biopsies from 6 patients with glioblastoma multiforme were disaggregated and single cells were treated in vitro with various concentrations of 1,3-bis(2-chloroethyl)-1-nitroso urea (BCNU) and plated for cell survival. One patient's cells were sensitive to BCNU in vitro; after a single dose of BCNU her brain scan reverted to normal and she was clinically well. Five tumours demonstrated resistance in vitro. Three of these tumours progressed during the first course of chemotherapy with a nitrosourea and the patients died at 21/2, 4 and 81/2 months after operation. Two patients who showed dramatic responses to radiation therapy were considered unchanged after the first course of nitrosourea therapy (although one demonstrated tumour enlargement on brain scan). The correlation of in vitro testing of tumour cell sensitivity with actual patient response is encouraging enough to warrant further work to determine whether such tests should weigh in decisions on patient therapy.

  4. [Diagnostic accuracy of malignancy risk index II in post-menopausal women with adnexal tumours].

    Science.gov (United States)

    Treviño-Báez, Joaquín Darío; Cantú-Cruz, Javier Alejandro; Medina-Mercado, Javier; Abundis, Alberto

    2016-01-01

    The purpose of the diagnostic evaluation of adnexal tumours is to exclude the possibility of malignancy. The malignancy risk index II identifies patients at high risk for ovarian cancer. The cut-off value is greater than 200. To evaluate the diagnostic accuracy of malignancy risk index II in post-menopausal women with adnexal tumours in relation to the histopathological results. A total of 138 women with an adnexal mass were studied. The malignancy risk index II was determined in all of them. They were divided into two groups according to the histopathology results; 69 patients with benign tumours and 69 patients with malignant tumours. A diagnostic test type analysis was performed with respect to the results of malignancy risk index II ≤ 200 or greater than this. The percentages and 95% confidence intervals were calculated. The accuracy was 81.8% (75.5-88.3), sensitivity 76.8% (66.9-86.7), specificity 87% (79.1-94.9), with a positive predictive value of 85.5% (76.7-94.3), and a negative predictive value of 78.9% (69.7-88.1). The positive likelihood ratio was 590, and the negative likelihood ratio was 0.266. The malignancy risk index II has good performance in the proper classification of post-menopausal women with adnexal masses, both benign and malignant, with an accuracy of 81.8%. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  5. Leucine-rich diet alters the 1H-NMR based metabolomic profile without changing the Walker-256 tumour mass in rats.

    Science.gov (United States)

    Viana, Laís Rosa; Canevarolo, Rafael; Luiz, Anna Caroline Perina; Soares, Raquel Frias; Lubaczeuski, Camila; Zeri, Ana Carolina de Mattos; Gomes-Marcondes, Maria Cristina Cintra

    2016-10-03

    Cachexia is one of the most important causes of cancer-related death. Supplementation with branched-chain amino acids, particularly leucine, has been used to minimise loss of muscle tissue, although few studies have examined the effect of this type of nutritional supplementation on the metabolism of the tumour-bearing host. Therefore, the present study evaluated whether a leucine-rich diet affects metabolomic derangements in serum and tumour tissues in tumour-bearing Walker-256 rats (providing an experimental model of cachexia). After 21 days feeding Wistar female rats a leucine-rich diet, distributed in L-leucine and LW-leucine Walker-256 tumour-bearing groups, we examined the metabolomic profile of serum and tumour tissue samples and compared them with samples from tumour-bearing rats fed a normal protein diet (C - control; W - tumour-bearing groups). We utilised 1 H-NMR as a means to study the serum and tumour metabolomic profile, tumour proliferation and tumour protein synthesis pathway. Among the 58 serum metabolites examined, we found that 12 were altered in the tumour-bearing group, reflecting an increase in activity of some metabolic pathways related to energy production, which diverted many nutrients toward tumour growth. Despite displaying increased tumour cell activity (i.e., higher Ki-67 and mTOR expression), there were no differences in tumour mass associated with changes in 23 metabolites (resulting from valine, leucine and isoleucine synthesis and degradation, and from the synthesis and degradation of ketone bodies) in the leucine-tumour group. This result suggests that the majority of nutrients were used for host maintenance. A leucine rich-diet, largely used to prevent skeletal muscle loss, did not affect Walker 256 tumour growth and led to metabolomic alterations that may partially explain the positive effects of leucine for the whole tumour-bearing host.

  6. Parotid gland tumours: a six years experience

    International Nuclear Information System (INIS)

    Malik, K.A.

    2006-01-01

    To find out the different types of Parotid tumours in out setup and their prevalence in different age groups. All patients admitted with Parotid swellings, irrespective of age and sex. The detailed data of the patients was collected and analyzed. A total of 27 patients, 15 males and 12 females, with ages ranging from 15 to 65 years were included in the study. Most of the patients were in the 31-50 years of age group. Pleomorphic adenoma was the commonest benign tumour with an incidence of 66.6%, while Mucoepidermoid Carcinoma with an incidence of 11.11% was the most common malignant tumour. Parotid gland is the principal site of salivary gland tumours. Males are affected more and Pleomorphic adenoma is the most common benign and Mucoepidermoid carcinoma the most common malignant tumour. (author)

  7. 99mTechnetium labelled vasoactive intestinal peptide analogue for rapid localization of tumours in humans

    International Nuclear Information System (INIS)

    Thakur, M.L.; Pallela, V.; Marcus, C.S.; Diggles, L.; Pham, H.L.; Ahdoot, R.; Kalinowski, E.A.; Saeed, S.; Minami, C.

    2001-01-01

    In recent years, imaging tumours with receptor specific biomolecules has been the focus of increasing interest. VIP has a high affinity for specific receptors that are expressed in high density on a large number of malignant tumours. VIP was modified (TP 3654) without compromising its biological activity, and labelled with 99m Tc. Pharmacokinetics and feasibility studies were performed in three normal volunteers and 11 patients with a history of cancer. Imaging was performed for up to two h post-injection. Within 24 h after injection of 99m Tc-TP 3654 (10-15 mCi/5 μg), approximately 70% of the tracer cleared through the kidneys, and 20% through the liver. Blood clearance was rapid. No adverse reaction was noted in any subjects. All known tumours were clearly delineated within 20 min. Findings were compared with the results of 99m Tc-MIBI, CT, MRI, or histology. There was concordance in nine patients. In the other two, only the VIP scan was positive for tumours known to express VIP receptors. The early results of imaging tumours with 99m Tc-VIP are promising and warrant further studies. (author)

  8. Interobserver delineation variation in lung tumour stereotacticbody radiotherapy

    DEFF Research Database (Denmark)

    Persson, G. F.; Nygaard, D. E.; Hollensen, Christian

    2012-01-01

    the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three......-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours....

  9. [Occurrence of associated tumours in chronic lymphocytic leukemia].

    Science.gov (United States)

    Szerafin, László; Jakó, János; Varju, Lóránt

    2016-10-01

    Chronic lymphocytic leukemia is one of the most common hematologic malignancy. The aim of the authors was to investigate the characteristics of malignancies associated with chronic lymphocytic leukemia in patients diagnozed between 2000 and 2015. Data of patients with chronic lymphocytic leukemia who had other associated tumours were analysed using the Leukemia/Lymphoma Registry of the Szabolcs-Szatmár-Bereg County, Hungary and patient records. Between January 1, 2000 and December 31, 2015, 526 patients with chronic lymphocytic leukemia were diagnosed. 95 patients of the 526 patients (18.06%) were diagnosed as having associated other tumours. In 48/95 patients (50.5%) the first diagnosed tumour was chronic lymphocytic leukemia, in 23/95 patients (24.2%) the first recognized malignancy was the associated tumour, whereas in 24/95 patients (25.3%) synchron tumours were diagnosed. The number of patients with more than one associated tumour was 10/95 (10.5%). The total number of tumours was 107. The incidence of chronic lymphoid leukemia increased in the period between 2000 and 2015 as compared to the period between 1983 and 1999 (3.19 vs 5.65/100 000 person/year). The occurrence of associated malignancies increased as well (8.06% vs 18.06%). In addition to the most common tumours (colorectal, breast, lung, prostate), skin squamous cell carcinoma (17/95 patients; 17.9%) and melanoma (6/95 patients; 6.3%) also frequently occurred. The second malignancies were most frequently discovered after the diagnosis of chronic lymphocytic leukemia and synchron tumours accounting for 78.5% (84/107) of all associated tumours. The incidence of second malignancies decreased 10 years after the diagnosis of chronic lymphocytic leukemia. The possible reasons for the high frequency of other tumours associated with chronic lymphocytic leukemia are elderly age of patients, immunsuppressed state and, presumably, chemotherapy of patients with chronic lymphocytic leukemia. During the follow up

  10. Aqp 9 and Brain Tumour Stem Cells

    Directory of Open Access Journals (Sweden)

    Guri Fossdal

    2012-01-01

    Full Text Available Several studies have implicated the aquaporins (aqp 1, 4, and 9 in the pathogenesis of malignant brain tumours, suggesting that they contribute to motility, invasiveness, and oedema formation and facilitate metabolism in tumour cells under hypoxic conditions. We have studied the expression of aqp1, 4, and 9 in biopsies from glioblastomas, isolated tumour stem cells grown in a tumoursphere assay and analyzed the progenitor and differentiated cells from these cultures. We have compared these to the situation in normal rat brain, its stem cells, and differentiated cells derived thereof. In short, qPCR in tumour tissue showed presence of aqp1, 4, and 9. In the tumour progenitor population, aqp9 was markedly more highly expressed, whilst in tumour-derived differentiated cells, aqp4 was downregulated. However, immunostaining did not reveal increased protein expression of aqp9 in the tumourspheres containing progenitor cells; in contrast, its expression (both mRNA and protein was high in differentiated cultures. We, therefore, propose that aquaporin 9 may have a central role in the tumorigenesis of glioblastoma.

  11. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D. [Institute for Cancer Research and Treatment (IRCC), Candiolo, Torino (Italy)

    2012-05-15

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  12. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    International Nuclear Information System (INIS)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D.

    2012-01-01

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  13. Multiparametric imaging of patient and tumour heterogeneity in non-small-cell lung cancer: quantification of tumour hypoxia, metabolism and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Elmpt, Wouter van; Zegers, Catharina M.L.; Reymen, Bart; Even, Aniek J.G.; Oellers, Michel; Troost, Esther G.C.; Lambin, Philippe [Maastricht University Medical Centre, Department of Radiation Oncology (MAASTRO), GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Dingemans, Anne-Marie C. [Maastricht University Medical Centre, Department of Pulmonology, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Wildberger, Joachim E.; Das, Marco [Maastricht University Medical Centre, Department of Radiology, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Mottaghy, Felix M. [Maastricht University Medical Centre, Department of Nuclear Medicine, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); University Hospital RWTH Aachen University, Department of Nuclear Medicine, Aachen (Germany)

    2016-02-15

    Multiple imaging techniques are nowadays available for clinical in-vivo visualization of tumour biology. FDG PET/CT identifies increased tumour metabolism, hypoxia PET visualizes tumour oxygenation and dynamic contrast-enhanced (DCE) CT characterizes vasculature and morphology. We explored the relationships among these biological features in patients with non-small-cell lung cancer (NSCLC) at both the patient level and the tumour subvolume level. A group of 14 NSCLC patients from two ongoing clinical trials (NCT01024829 and NCT01210378) were scanned using FDG PET/CT, HX4 PET/CT and DCE CT prior to chemoradiotherapy. Standardized uptake values (SUV) in the primary tumour were calculated for the FDG and hypoxia HX4 PET/CT scans. For hypoxia imaging, the hypoxic volume, fraction and tumour-to-blood ratio (TBR) were also defined. Blood flow and blood volume were obtained from DCE CT imaging. A tumour subvolume analysis was used to quantify the spatial overlap between subvolumes. At the patient level, negative correlations were observed between blood flow and the hypoxia parameters (TBR >1.2): hypoxic volume (-0.65, p = 0.014), hypoxic fraction (-0.60, p = 0.025) and TBR (-0.56, p = 0.042). At the tumour subvolume level, hypoxic and metabolically active subvolumes showed an overlap of 53 ± 36 %. Overlap between hypoxic sub-volumes and those with high blood flow and blood volume was smaller: 15 ± 17 % and 28 ± 28 %, respectively. Half of the patients showed a spatial mismatch (overlap <5 %) between increased blood flow and hypoxia. The biological imaging features defined in NSCLC tumours showed large interpatient and intratumour variability. There was overlap between hypoxic and metabolically active subvolumes in the majority of tumours, there was spatial mismatch between regions with high blood flow and those with increased hypoxia. (orig.)

  14. Tracking errors in a prototype real-time tumour tracking system

    International Nuclear Information System (INIS)

    Sharp, Gregory C; Jiang, Steve B; Shimizu, Shinichi; Shirato, Hiroki

    2004-01-01

    In motion-compensated radiation therapy, radio-opaque markers can be implanted in or near a tumour and tracked in real-time using fluoroscopic imaging. Tracking these implanted markers gives highly accurate position information, except when tracking fails due to poor or ambiguous imaging conditions. This study investigates methods for automatic detection of tracking errors, and assesses the frequency and impact of tracking errors on treatments using the prototype real-time tumour tracking system. We investigated four indicators for automatic detection of tracking errors, and found that the distance between corresponding rays was most effective. We also found that tracking errors cause a loss of gating efficiency of between 7.6 and 10.2%. The incidence of treatment beam delivery during tracking errors was estimated at between 0.8% and 1.25%

  15. Comparison of robotic and laparoscopic partial nephrectomy for small renal tumours

    Directory of Open Access Journals (Sweden)

    Abdulmuttalip Simsek

    2017-06-01

    Full Text Available Objective: To evaluate a single surgeon oncological and functional outcomes of laparoscopic partial nephrectomy (LPN compared to robotic partial nephrectomy (RPN for pT1a renal tumours. Materials and methods: Between 2006 and 2016, a retrospective review of 42 patients who underwent LPN (n = 20 or RPN (n = 22 by same surgeon was performed. Patients were matched for gender, age, body mass index (BMI, American Society of Anaesthesiologists (ASA score, tumour side, RENAL and PADUA scores, peri-operative and post-operative outcomes. Results: There was no significant differences between the two groups with respect to patient gender, age, BMI, ASA score, tumours side, RENAL and PADUA scores. Mean operative time for RPN was 176 vs. 227 minutes for LPN (p = 0.001. Warm ischemia time was similar in both groups (p = 0.58. Estimated blood loss (EBL was higher in the LPN. There was no significant difference with preoperative and postoperative creatinine and percent change in eGFR levels. Only one case in LPN had positive surgical margin. Conclusions: RPN is a developing procedure, and technically feasible and safe for small-size renal tumours. Moreover RPN is a comparable and alternative operation to LPN, providing equivalent oncological and functional outcomes, as well as saving more healthy marginal tissue and easier and faster suturing.

  16. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  17. Supratentorial tumours. Part II: tumors of neurolglial cells

    International Nuclear Information System (INIS)

    Sage, M.R.

    1991-01-01

    Tumors arising from neuroglial cells are the most common primary brain tumours, representing approximately 45% of all tumours. A simplified classification of these tumours is given, based on the degree of anaplasia. Both computed tomography and magnetic resonance imaging appearance of such lesions is presented and the relevance of these techniques in the detection and differential diagnosis of neuroglial cells tumours is discussed. 39 refs., 1 tab., 11 figs

  18. Intraindividual comparison of 68Ga-DOTA-TATE and 18F-DOPA PET in patients with well-differentiated metastatic neuroendocrine tumours

    International Nuclear Information System (INIS)

    Haug, Alexander; Auernhammer, Christoph J.; Goeke, Burkhard; Waengler, Bjoern; Tiling, Reinhold; Bartenstein, Peter; Poepperl, Gabriele; Schmidt, Gerwin

    2009-01-01

    To compare the diagnostic impact of 68 Ga-DOTA-TATE and 18 F-DOPA PET in the diagnosis of well-differentiated metastatic neuroendocrine tumours (NET). PET/CT using both 68 Ga-DOTA-TATE and 18 F-DOPA was performed in 25 patients with histologically proven metastatic NET (nine gut, five pancreas, six lung, one paranasal sinus, four with unknown primary). Analyses of PET examinations were patient-based (pathological uptake: yes/no), and based on tumour regions (primary tumour if present and metastases of liver, lung, bones and lymph nodes). The results were compared with the results of contrast enhanced CT, and with plasma serotonin levels, which were available in 24 of the 25 patients. Patient-based sensitivities were 96% for 68 Ga-DOTA-TATE PET and 56% for 18 F-DOPA PET. 68 Ga-DOTA-TATE PET delineated metastases in 54 of 55 positive metastatic tumour regions in contrast to 29 of 55 delineated by 18 F-DOPA PET. Overall, 68 Ga-DOTA-TATE was superior to 18 F-DOPA in 13 patients (two patients showed fewer positive tumour regions with 18 F-DOPA PET). The results were comparable in 12 patients. In 13 of 24 patients, plasma serotonin levels were elevated, and 11 of these 13 patients showed pathological uptake of 18 F-DOPA. Of the 11 patients with normal levels of serotonin, 3 also showed positive 18 F-DOPA uptake. In patients positive for 18 F-DOPA uptake the maximum tumour SUVs were correlated with the levels of serotonin (r=0.66, p=0.01). In this study 68 Ga-DOTA-TATE PET proved clearly superior to 18 F-DOPA PET for detection and staging of NET. 18 F-DOPA uptake tended to be increased in those patients with elevated plasma serotonin. We conclude that 18 F-DOPA PET should be employed in patients with NET with negative 68 Ga-DOTA-TATE PET and elevated plasma serotonin. (orig.)

  19. Primitive neuroectodermal tumour (PNET) of the kidney: a rare renal tumour in adolescents with seemingly characteristic radiological features

    International Nuclear Information System (INIS)

    Chu, Winnie C.; Reznikov, Boris; Lee, Edward Y.; Grant, Ronald M.; Cheng, Frankie W.T.; Babyn, Paul

    2008-01-01

    Primitive neuroectodermal tumours (PNETs) constitute a family of neoplasms of presumed neuroectodermal origin that predominantly present as bone or soft-tissue masses in adolescents and young adults. PNET arising in the kidney is rare. To describe the radiological features in three patients with primary renal PNET. The radiological features of primary renal PNET in three adolescent patients (age 10, 14 and 16 years) are described. Tumour thrombus extending into the renal vein and inferior vena cava was noted in all three patients. In addition, further tumour extension into the atrium was seen in two patients with extension into a pulmonary artery in one patient. Neural foraminal and intraspinal extension close to the origin of the tumour was identified in two patients. Liver, bone and lung metastases were identified. While rare, one should consider the diagnosis of PNET when encountering a renal mass with aggressive features such as inferior vena cava tumour thrombus, direct intraspinal invasion and distant metastasis. (orig.)

  20. Comparison of auxin activty in tumourous and normal callus cultures from sunflower and tobacco plants

    Directory of Open Access Journals (Sweden)

    Z. Chirek

    2015-01-01

    Full Text Available In normal and tumourous calluses of sunflower and tobacco the level of extractable auxins was determined by Avena coleoptile straight growth test. Auxin activity was detected practically in two zones: I - at position with Rf 0.2-0.4 and II - at position with Rf 0.6-0.9. The tumour tissues of sunflower and tobacco plants, representing different types of neoplastic growth exhibit a 3 times higher auxin activity as compared with that of the corresponding normal tissues. Tobacco tissues, on the other hand, had a higher auxin level than the corresponding sunflower tissues and they exhibited different proportions in the activity of zones I and II, which points to a dominance of genetic regulation of hormone metabolism in these plants.

  1. Response and recovery kinetics of a solid tumour after irradiation

    International Nuclear Information System (INIS)

    Rowley, R.; Hopkins, H.A.; Ritenour, E.R.; Looney, W.B.

    1980-01-01

    The effects of local tumour radiation over the dose range 7.5-30 Gy on the growth and cell kinetics of rat hepatoma H-4-II-E have been investigated. A plot of growth delays against log surviving fraction was linear below a fraction of 0.03, but failed to extrapolate to the origin. Following a single dose of 15 Gy to the tumour, DNA-precursor incorporation, labelling and mitotic indices were depressed for 7 days. Tumour cellularity, measured as DNA/g tumour was reduced and the rate of increase of total clonogenic cells slower than after complete tumour recovery. From Day 7 to Day 9 all indices of proliferation recovered to about control levels, clonogenic cell numbers increased more rapidly and tumour cellularity was restored. Repopulation of the tumour therefore appeared to take place mainly after Day 7. Incorporation of [ 3 H]-TdR into tumour DNA reached twice the control values on Day 9. The rate of tumour growth accelerated after the initial decrease, and maximum tumour growth rate was also twice the control values on Day 13. Accelerated growth rates in irradiated tumours, above those of control tumours, occurred 10-16 days after treatment. The effectiveness of sequential therapy may therefore be improved if given during this period of accelerated tumour growth. (author)

  2. Presentation of a salivary tumour si mil primitive lung with metastases of carcinoid tumour of the colon

    International Nuclear Information System (INIS)

    Cataldi, S.; Ximenez; Carzoglio, J.

    2010-01-01

    Introduction: Colon carcinoid tumors are primary tumors in the colon, a rare histology. The lung tumour Si mil - Amyloid is within primary lung tumours, infrequent histology and often behaves like a benign tumour. In this paper we present the case of a patient with a history of having undergone colon surgery for a malignant carcinoid. Two years after developing a lung salivary tumour simile initially presented as metastasis Colonic carcinoid lung tumour. Clinical case: It is about a female patient of 64 years, who in September 2008 he makes a right hemicolectomy extended by an occlusive syndrome sub. Anatomic Pathology (A P) accounted for Carcinoid Tumor Malignant one that committed the entire wall and 50 lymph nodes are resected, all free metastasis. The patient does not receive complementary treatments and an imaging over in December 2009 is evident in a tomographic study a bulky upper lobe pulmonary parenchymal process right. The fiberoptic bronchoscopy (Fob) showed complete obstruction of the right upper lobe bronchus by a vegetating process whose biopsy reported a malignant lung tumor commitment carcinoid support primitive colonic confirmed by immunohistochemistry (IHC). The March 23, 2010 takes place the right upper lobectomy with lymphadenectomy. The A P and IHC study confirmed adenosquamous carcinoma with stroma simile amiloide low degree of malignancy. This injury can be approved to a salivary tumour early lung simile. Bronchial compromised by tumor margin and 22 negative lymph nodes. The patient is referred for additional radiation treatment. Discussion: Tumours of salivary gland type of primitive lung is a very rare condition and diagnosis is a r arity . Usually they originate in the bronchial epithelium submucosal gland. Endo luminal lesions usually occur as infrequently and develop in outlying areas. The development of lung tumours unrelated bronchial structure has been explained by a possible origin from a primitive stem cell that can differentiate a

  3. Tumours associated with medical X-ray therapy exposure in childhood

    International Nuclear Information System (INIS)

    Colman, M.; Kirsch, M.; Creditor, M.

    1978-01-01

    A total of 5166 persons who were exposed to limited field (80-100 cm 2 ) X-ray irradiation to the head, neck and upper chest region during childhood and adolescence have provided an outstanding opportunity for the study of tumour incidence following medical X-ray therapy. More than 3254 subjects have been traced, 3108 have completed questionnaires eliciting information on tumour incidence, and 1539 of these were subjected to a thorough clinical screening procedure that included a thyroid scintigram. The prevalence of thyroid tumours in the 1539 clinically screened subjects and the prevalence of all other tumours in the 3254 subjects traced can therefore be assumed to reflect the risks in the group of irradiated subjects as a whole. Median age at irradiation was 3.5 years, and median radiation dose 790 rads (7.9 Gy). Thyroid tumour was diagnosed in 413 subjects. Of those undergoing surgery (273) 30.3% were found to have thyroid cancer. A total of 366 surgical pathology specimens of the thyroid, including 93 from subjects who were diagnosed at other hospitals, were examined revealing 73 papillary carcinomas, 12 follicular carcinomas and 26 microscopic papillary carcinomas. One hundred and eighty-seven other (non-thyroid) neoplasmas identified included 27 benign and 10 malignant salivary gland tumours, 16 benign and seven malignant tumours of neural origin (brain, spinal cord, cranial and peripheral nerves), 37 skin tumours, 9 lymphomas, 8 gonadal tumours, 45 breast tumours and 28 tumours of miscellaneous sites. The incidence of thyroid tumours, salivary gland tumours and primary brain tumours was considerably in excess of the expected incidence (p values<0.0001), and a radiation dose-effect correlation was observed for thyroid and brain tumours. Gonadal tumours and lymphomas did not occur in excess of the expected incidence

  4. SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Cui, G; Trakul, N; Chang, E; Shiu, A

    2016-01-01

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

  5. SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Cui, G; Trakul, N; Chang, E; Shiu, A [University Southern California, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

  6. Measurement of tumour size with mammography, sonography and magnetic resonance imaging as compared to histological tumour size in primary breast cancer

    International Nuclear Information System (INIS)

    Gruber, Ines V; Rueckert, Miriam; Kagan, Karl O; Staebler, Annette; Siegmann, Katja C; Hartkopf, Andreas; Wallwiener, Diethelm; Hahn, Markus

    2013-01-01

    Tumour size in breast cancer influences therapeutic decisions. The purpose of this study was to evaluate sizing of primary breast cancer using mammography, sonography and magnetic resonance imaging (MRI) and thereby establish which imaging method most accurately corresponds with the size of the histological result. Data from 121 patients with primary breast cancer were analysed in a retrospective study. The results were divided into the groups “ductal carcinoma in situ (DCIS)”, invasive ductal carcinoma (IDC) + ductal carcinoma in situ (DCIS)”, “invasive ductal carcinoma (IDC)”, “invasive lobular carcinoma (ILC)” and “other tumours” (tubular, medullary, mucinous and papillary breast cancer). The largest tumour diameter was chosen as the sizing reference in each case. Bland-Altman analysis was used to determine to what extent the imaging tumour size correlated with the histopathological tumour sizes. Tumour size was found to be significantly underestimated with sonography, especially for the tumour groups IDC + DCIS, IDC and ILC. The greatest difference between sonographic sizing and actual histological tumour size was found with invasive lobular breast cancer. There was no significant difference between mammographic and histological sizing. MRI overestimated non-significantly the tumour size and is superior to the other imaging techniques in sizing of IDC + DCIS and ILC. The histological subtype should be included in imaging interpretation for planning surgery in order to estimate the histological tumour size as accurately as possible

  7. Evaluating the agreement between tumour volumetry and the estimated volumes of tumour lesions using an algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Laubender, Ruediger P. [German Cancer Consortium (DKTK), Heidelberg (Germany); University Hospital Munich - Campus Grosshadern, Institute of Medical Informatics, Biometry, and Epidemiology (IBE), Munich (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); Lynghjem, Julia; D' Anastasi, Melvin; Graser, Anno [University Hospital Munich - Campus Grosshadern, Institute for Clinical Radiology, Munich (Germany); Heinemann, Volker; Modest, Dominik P. [University Hospital Munich - Campus Grosshadern, Department of Medical Oncology, Munich (Germany); Mansmann, Ulrich R. [University Hospital Munich - Campus Grosshadern, Institute of Medical Informatics, Biometry, and Epidemiology (IBE), Munich (Germany); Sartorius, Ute; Schlichting, Michael [Merck KGaA, Darmstadt (Germany)

    2014-07-15

    To evaluate the agreement between tumour volume derived from semiautomated volumetry (SaV) and tumor volume defined by spherical volume using longest lesion diameter (LD) according to Response Evaluation Criteria In Solid Tumors (RECIST) or ellipsoid volume using LD and longest orthogonal diameter (LOD) according to World Health Organization (WHO) criteria. Twenty patients with metastatic colorectal cancer from the CIOX trial were included. A total of 151 target lesions were defined by baseline computed tomography and followed until disease progression. All assessments were performed by a single reader. A variance component model was used to compare the three volume versions. There was a significant difference between the SaV and RECIST-based tumour volumes. The same model showed no significant difference between the SaV and WHO-based volumes. Scatter plots showed that the RECIST-based volumes overestimate lesion volume. The agreement between the SaV and WHO-based relative changes in tumour volume, evaluated by intraclass correlation, showed nearly perfect agreement. Estimating the volume of metastatic lesions using both the LD and LOD (WHO) is more accurate than those based on LD only (RECIST), which overestimates lesion volume. The good agreement between the SaV and WHO-based relative changes in tumour volume enables a reasonable approximation of three-dimensional tumour burden. (orig.)

  8. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    International Nuclear Information System (INIS)

    Wilbert, Jürgen; Guckenberger, Matthias; Polat, Bülent; Sauer, Otto; Vogele, Michael; Flentje, Michael; Sweeney, Reinhart A

    2010-01-01

    To introduce a novel method of patient positioning for high precision intracranial radiotherapy. An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort

  9. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results

    Directory of Open Access Journals (Sweden)

    Flentje Michael

    2010-05-01

    Full Text Available Abstract Background To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods An infrared(IR-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP and connected to the table via a 6 degree-of-freedom(DoF mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT is performed. A robotic 6 DoF treatment couch (HexaPOD™ then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102 was 1.6 ± 0.8 mm while intra-fraction movement (n = 110 was 0.6 ± 0.4 mm. Conclusions This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient

  10. Ovarian tumours in children : A review of 18 cases

    Directory of Open Access Journals (Sweden)

    Abdelouhab Ammor

    2012-01-01

    Full Text Available Background : To review the experience of Children′s Hospital of Rabat in managing ovarian tumours in children. Materials and Methods: There were 18 patients between 2 and 15 years of age who presented with an ovarian tumour at Children′s Hospital of Rabat between January 2000 and December 2008. Data collected from the hospital medical records included age at diagnosis, patient′s history, presenting complaints, radiological examination, tumour markers, management, operative procedure, histopathological examination and outcome of the patients. Results : The most common presenting complaint was abdominal pain in 10 (55% patient. 77% of ovarian tumours were germ cell tumours; 71% of these were teratomas which were benign in 66% of cases. Unilateral salpingo-oophorectomy was the most common surgical procedure performed in 15 patients (83% through laparotomy. Laparoscopic ovarian cystectomy was carried out in 2 (11% patients with benign cystic teratoma. Of the 7 (39% patients with malignant tumours, three received postoperative chemotherapy. Outcome was good in most cases. There were no cases of resistance to treatment, or death. Conclusion : Early diagnosis of ovarian tumours in children and adolescents is important. Since most of these tumours are benign, surgical treatment should be conservative to minimise the risk of subsequent infertility, while the treatment of malignant tumours should include complete staging, resection of the tumour, postoperative chemotherapy when indicated, to give the patient a chance for future childbearing.

  11. Tumours of the pineal region in childhood

    International Nuclear Information System (INIS)

    Herrmann, H.D.; Schulte, F.J.; Winkler, D.; Mueller, D.

    1988-01-01

    36 patients with tumours in the pineal region were treated between 1980 and 1986, 19 of whom were under 20 years of age. Diagnosis was based on cranial CT, supplemented to by MRI as from 1986. Preoperative angiography was peformed on all patients to demonstrate tumour vascularization and type of vascular supply. Stereotactic biopsies were complemented by intraoperative ventriculography. Stereotactic biopsy only was performed in 13 patients out of the total group to verify tumour histology. 23 patients were directly operated on primarily. 3 of these died postoperative. In cases of germ-cell tumours and pineal blastomas the total brain and the vertebral canal were irradiated. (orig./MG) [de

  12. Peptide receptor radionuclide therapy of neuroendocrine tumours

    International Nuclear Information System (INIS)

    Bodei, L.; Giammarile, F.

    2009-01-01

    Neuroendocrine tumours are considered relatively rare tumours that have the characteristic property of secreting bioactive substances, such as amines and hormones. They constitute a heterogeneous group, characterized by good prognosis, but important disparities of the evolutionary potential. In the aggressive forms, the therapeutic strategies are limited. The metabolic or internal radiotherapy, using radiolabelled peptides, which can act at the same time on the primary tumour and its metastases, constitutes a tempting therapeutic alternative, currently in evolution. The prospects are related to the development of new radiopharmaceuticals, with the use of other peptide analogues whose applications will overflow the framework of the neuro-endocrine tumours. (authors)

  13. Tumour localization and pharmacokinetics of iodine-125 human monoclonal IgM antibody (COU-1) and its monomeric and half-monomeric fragments analysed in nude mice grafted with human tumour

    International Nuclear Information System (INIS)

    Ditzel, H.; Erb, K.; Rasmussen, J.W.; Jensenius, J.C.

    1992-01-01

    Human monoclonal IgM antibodies reactive with cancer-associated antigens may not have the optimal imaging capability due to their large size. Fragmentation of human IgM is less than straight-forward due to the loss of immunoreactivity. From the human monoclonal IgM antibody COU-1 we have prepared monomeric and half-monomeric fragments, which retain the ability to bind to colon cancer cells in vitro. The pharmacokinetics and tumour localization were evaluated in nude mice bearing human colon adenocarcinoma and human melanoma grafts. Faster clearance from the circulation was seen for the smaller half-monomeric fragment with a half-life (rapid phase/slow phase) of 2 h/16 h compared with the intact antibody, 4 h/25 h, and the monomeric fragment, 3 h/27 h. Intact COU-1 as well as the fragments accumulated in the colon tumour graft. Higher amounts of radioactivity were found in the colon tumour as compared to normal organs for intact COU-1 at days 4 and 6, for the monomeric fragment at day 4, and for the half-monomeric fragment at day 2 after injection. This investigation demonstrates the favourable biodistribution of the half monomeric COU-1 fragment. The fast clearance of this fragment resulted in a tumour-to-muscle ratio as high as 22 on day 2 after injection. Also, only this fragment gave a positive tumour-to-blood ratio. Normal IgM and its fragments were used as controls. Radioimmunoscintigraphy demonstrated the colon tumour discriminatory properties of each of the three iodine-labelled antibody preparations. The results compare favourably with previously reported investigations of the localization of human monoclonal antibodies and suggest that fragments of human monoclonal IgM antibodies may be useful tools for the immunodetection of cancer in patients. (orig.)

  14. Malignant Peripheral Nerve Sheath Tumour of the Maxilla

    Directory of Open Access Journals (Sweden)

    Puja Sahai

    2014-01-01

    Full Text Available A 38-year-old man was diagnosed with malignant peripheral nerve sheath tumour of the maxilla. He was treated with total maxillectomy. Histopathological examination of the resected specimen revealed a close resection margin. The tumour was of high grade with an MIB-1 labelling index of almost 60%. At six weeks following the surgery, he developed local tumour relapse. The patient succumbed to the disease at five months from the time of diagnosis. The present report underlines the locally aggressive nature of malignant peripheral nerve sheath tumour of the maxilla which necessitates an early therapeutic intervention. A complete resection with clear margins is the most important prognostic factor for malignant peripheral nerve sheath tumour in the head and neck region. Adjuvant radiotherapy may be considered to improve the local control. Future research may demarcate the role of targeted therapy for patients with malignant peripheral nerve sheath tumour.

  15. An unusual presentation of a glomus tumour.

    LENUS (Irish Health Repository)

    Nugent, N

    2011-02-01

    Glomus tumours are benign, soft tissue tumours, usually of fingertips. Classically they present with severe pain, temperature sensitivity and localised tenderness. The diagnosis is often delayed due to sometimes non-specific symptoms and rarity of the disorder. While usually a clinical diagnosis, imaging may be necessary for diagnosis and localisation. We present a case of glomus tumour of the fingertip with an unusual history.

  16. Patient Survival Periods and Death Causes Following Surgical Treatment of Mammary Gland Tumours Depending on Histological Type of Tumour: Retrospective Study of 221 Cases

    Directory of Open Access Journals (Sweden)

    Jana Lorenzová

    2010-01-01

    Full Text Available This retrospective study evaluated a canine patient group operated on for mammary neoplasms (221 females. After surgical treatment, the animals were divided based on histological findings into groups and subgroups according to the WHO system. In the individual groups and subgroups the length of their survival following a mammary tumour surgery and death causes were followed. Of their total number, 164 tumours were malignant, 39 were benign and 18 were mammary hyperplasias. With regard to malignant tumours, invasive tubular carcinoma (20.81% was identified most frequently; fibroadenoma reached the highest occurrence (10.41% as regards benign tumours. The length of survival in females with malignant tumours ranged from 12 to 37.4 months, depending on histological subtypes. In females with benign mammary neoplasms the length of survival ranged from 39.1 to 59.3 months and in animals with hyperplasia it was 50.2 months. As a result of mammary tumour, 41 females (25% died in the malignant tumour group, none died in the benign tumour group and 2 females (11.1% died in the hyperplasia group. The survival periods in surgically treated patients with mammary tumours were shorter for solid and complex carcinomas, compared to patients affected with the remainder of the histological subtypes. The longest survival period following operation was recorded in the group suffering from adenoma. The least favourable illness prognosis for patients with mammary tumours in respect to linking the death cause to the mammary tumour was for those having invasive papillary carcinoma. The most favourable illness prognosis was for patients with benign tumours and non-invasive tubular carcinoma. A frequent death cause in females with mammary tumours was another illness unrelated to mammary tumours.

  17. Primary malignant bone tumour in a tropical African University ...

    African Journals Online (AJOL)

    Bone tumours are relatively rare tumours as compared with all other tumours. The relative frequency has not been well documented in this environment. The aim of the study was to define the frequency of primary malignant bone tumours in an African University teaching hospital in Ibadan. The medical records of 114 ...

  18. [Gender differences in the use of tumour markers].

    Science.gov (United States)

    Moreno-Campoy, E E; Mérida-De la Torre, F J; Martos-Crespo, F; Plebani, M

    2015-01-01

    Gender is one of the factors that can influence the use of health resources. The use of tumour markers is widespread, due to the importance of these in monitoring cancer development. The aim of this study is to analyse the influence of gender on the use of tumour markers, and to investigate whether there are differences in their use. A longitudinal, retrospective and descriptive study, with a 2-year follow-up, was conducted in the catchment area of the University Hospital of Padua. An analysis was performed on 23,059 analytical requests for tumour markers. A descriptive and frequency analysis was performed on all variables. The statistical analysis was performed using Chi squared, Student t and Mann-Whitney U to test for significance. The number of requests for women (1.5) was lower than men (1.6). In patients with tumour pathology, the number of requests was higher than in patients without tumour disease. In the analysis by disease and gender, the difference remained significant. As regards the number of tumour markers per request, the difference between genders was also significant: 2.13 in males versus 2.85 in women. Similar results were obtained when requests for tumour markers linked to gender-related diseases were eliminated. There are differences in the use of tumour markers by gender with the number of requests for male patients being higher than for females. However, the number of tumour markers per request is greater in women than in men. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  19. Nuclear medicine procedures to diagnose endocrine pancreatic tumours

    International Nuclear Information System (INIS)

    Bares, R.; Besenfelder, H.; Eschmann, S.M.; Pfannenberg, C.

    2003-01-01

    The typical clinical features of endocrine pancreatic tumours are either symptoms caused by excessive hormone production or progressive tumour growth. In several prospective studies it has been shown that somatostatin receptor scintigraphy is the most accurate imaging technique currently available to detect endocrine pancreatic tumours. Therefore it should be used whenever curative surgical treatment appears to be feasible. Furthermore it should be applied if a radionuclide treatment of inoperable tumours is considered. In this situation scintigraphy with 123 I-mIBG might be useful, too. Future developments include the use of PET with labelled somatostatin analogues or DOPA derivatives as well as image fusion techniques to optimize preoperative tumour localization. (orig.) [de

  20. WE-DE-BRA-01: SCIENCE COUNCIL JUNIOR INVESTIGATOR COMPETITION WINNER: Acceleration of a Limited-Angle Intrafraction Verification (LIVE) System Using Adaptive Prior Knowledge Based Image Estimation

    International Nuclear Information System (INIS)

    Zhang, Y; Yin, F; Ren, L; Zhang, Y

    2016-01-01

    Purpose: To develop an adaptive prior knowledge based image estimation method to reduce the scan angle needed in the LIVE system to reconstruct 4D-CBCT for intrafraction verification. Methods: The LIVE system has been previously proposed to reconstructs 4D volumetric images on-the-fly during arc treatment for intrafraction target verification and dose calculation. This system uses limited-angle beam’s eye view (BEV) MV cine images acquired from the treatment beam together with the orthogonally acquired limited-angle kV projections to reconstruct 4D-CBCT images for target verification during treatment. In this study, we developed an adaptive constrained free-form deformation reconstruction technique in LIVE to further reduce the scanning angle needed to reconstruct the CBCT images. This technique uses free form deformation with energy minimization to deform prior images to estimate 4D-CBCT based on projections acquired in limited angle (orthogonal 6°) during the treatment. Note that the prior images are adaptively updated using the latest CBCT images reconstructed by LIVE during treatment to utilize the continuity of patient motion.The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of this technique with LIVE system. A lung patient was simulated with different scenario, including baseline drifts, amplitude change and phase shift. Limited-angle orthogonal kV and beam’s eye view (BEV) MV projections were generated for each scenario. The CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate the reconstruction accuracy. Results: Using orthogonal-view of 6° kV and BEV- MV projections, the VPD/COMS values were 12.7±4.0%/0.7±0.5 mm, 13.0±5.1%/0.8±0.5 mm, and 11.4±5.4%/0.5±0.3 mm for the three scenarios, respectively. Conclusion: The

  1. WE-DE-BRA-01: SCIENCE COUNCIL JUNIOR INVESTIGATOR COMPETITION WINNER: Acceleration of a Limited-Angle Intrafraction Verification (LIVE) System Using Adaptive Prior Knowledge Based Image Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y; Yin, F; Ren, L [Duke University Medical Center, Durham, NC (United States); Zhang, Y [UT Southwestern Medical Ctr at Dallas, Dallas, TX (United States)

    2016-06-15

    Purpose: To develop an adaptive prior knowledge based image estimation method to reduce the scan angle needed in the LIVE system to reconstruct 4D-CBCT for intrafraction verification. Methods: The LIVE system has been previously proposed to reconstructs 4D volumetric images on-the-fly during arc treatment for intrafraction target verification and dose calculation. This system uses limited-angle beam’s eye view (BEV) MV cine images acquired from the treatment beam together with the orthogonally acquired limited-angle kV projections to reconstruct 4D-CBCT images for target verification during treatment. In this study, we developed an adaptive constrained free-form deformation reconstruction technique in LIVE to further reduce the scanning angle needed to reconstruct the CBCT images. This technique uses free form deformation with energy minimization to deform prior images to estimate 4D-CBCT based on projections acquired in limited angle (orthogonal 6°) during the treatment. Note that the prior images are adaptively updated using the latest CBCT images reconstructed by LIVE during treatment to utilize the continuity of patient motion.The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of this technique with LIVE system. A lung patient was simulated with different scenario, including baseline drifts, amplitude change and phase shift. Limited-angle orthogonal kV and beam’s eye view (BEV) MV projections were generated for each scenario. The CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate the reconstruction accuracy. Results: Using orthogonal-view of 6° kV and BEV- MV projections, the VPD/COMS values were 12.7±4.0%/0.7±0.5 mm, 13.0±5.1%/0.8±0.5 mm, and 11.4±5.4%/0.5±0.3 mm for the three scenarios, respectively. Conclusion: The

  2. Primary Malignant Bone Tumours at the University Teaching ...

    African Journals Online (AJOL)

    Introduction: Primary malignant bone tumours include malignancies arising primarily from bone tissue. This is opposed to secondary bone tumours in which case the neoplastic elements arise primarily from other sites within the body and secondarily spread to bone. Primary malignant bone tumours are generally ...

  3. Malignant insulinoma: The problems of tumour localization and ...

    African Journals Online (AJOL)

    Malignant insulinomas of the pancreas are rare tumours, accounting for 10% of ... Histological examination showed a R-cell malignant tumour of the pancreas with ... Associated vaso-. SA MEDICAL JOURNAL VOLUME 63 23 APRIL 1983 ... 52 cases of pancreatic endocrine malignant tumours, which have similar behaviour.

  4. Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images

    International Nuclear Information System (INIS)

    Ju, Sang Gyu; Hong, Chae Seon; Park, Hee Chul; Ahn, Jong Ho; Shin, Eun Hyuk; Shin, Jung Suk; Kim, Jin Sung; Han, Young Yih; Lim, Do Hoon; Choi, Doo Ho

    2010-01-01

    In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimensional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Medians of inter

  5. Association of primary tumour FDG uptake with clinical, histopathological and molecular characteristics in breast cancer patients scheduled for neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, B.B.; Aukema, T.S. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Surgical Oncology, Amsterdam (Netherlands); Vrancken Peeters, M.J.T.F.D.; Rutgers, E.J.T. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Surgical Oncology, Amsterdam (Netherlands); Wesseling, J.; Lips, E.H. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Pathology and Experimental Therapy, Amsterdam (Netherlands); Vogel, W.V.; Valdes Olmos, R.A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Werkhoven, E. van [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Biometrics, Amsterdam (Netherlands); Gilhuijs, K.G.A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Radiology, Amsterdam (Netherlands); University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands); Rodenhuis, S. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Medical Oncology, Amsterdam (Netherlands)

    2012-12-15

    The aim of this study was to evaluate the association of primary tumour {sup 18}F-fluorodeoxyglucose (FDG) uptake with clinical, histopathological and molecular characteristics of breast cancer patients scheduled for neoadjuvant chemotherapy. Second, we wished to establish for which patients pretreatment positron emission tomography (PET)/CT could safely be omitted because of low FDG uptake. PET/CT was performed in 214 primary stage II or III breast cancer patients in the prone position with hanging breasts. Tumour FDG uptake was qualitatively evaluated to determine the possibility of response monitoring with PET/CT and was quantitatively assessed using maximum standardized uptake values (SUV{sub max}). FDG uptake was compared with age, TNM stage, histology, hormone and human epidermal growth factor receptor 2 status, grade, Ki-67 and molecular subtype in univariable and multivariable analyses. In 203 tumours (95 %) FDG uptake was considered sufficient for response monitoring. No subgroup of patients with consistently low tumour FDG uptake could be identified. In a univariable analysis, SUV{sub max} was significantly higher in patients with distant metastases at staging examination, non-lobular carcinomas, tumours with negative hormone receptors, triple negative tumours, grade 3 tumours, and in tumours with a high proliferation index (Ki-67 expression). After multiple linear regression analysis, triple negative and grade 3 tumours were significantly associated with a higher SUV{sub max}. Primary tumour FDG uptake in breast cancer patients scheduled for neoadjuvant chemotherapy is significantly higher in tumours with prognostically unfavourable characteristics. Based on tumour characteristics associated with low tumour FDG uptake, this study was unable to identify a subgroup of patients unlikely to benefit from pretreatment PET/CT. (orig.)

  6. Surgical technique for en bloc transurethral resection of bladder tumour with a Hybrid Knife(®).

    Science.gov (United States)

    Islas-García, J J O; Campos-Salcedo, J G; López-Benjume, B I; Torres-Gómez, J J; Aguilar-Colmenero, J; Martínez-Alonso, I A; Gil-Villa, S A

    2016-05-01

    Bladder cancer is the second most common malignancy of the urinary tract and the 9th worldwide. Latin American has an incidence of 5.6 per 100,000 inhabitants per year. Seventy-five percent of newly diagnosed cases are nonmuscle invasive bladder cancer, and 25% of cases present as muscle invasive. The mainstay of treatment for nonmuscle invasive bladder cancer is loop transurethral resection. In 2013, the group led by Dr Mundhenk of the University Hospital of Tübingen, Germany, was the first to describe the Hybrid Knife(®) equipment for performing en bloc bladder tumour resection, with favourable functional and oncological results. To describe the surgical technique of en bloc bladder tumour resection with a Hybrid Knife(®) as an alternative treatment for nonmuscle invasive bladder tumours. A male patient was diagnosed by urotomography and urethrocystoscopy with a bladder tumour measuring 2×1cm on the floor. En bloc transurethral resection of the bladder tumour was performed with a Hybrid Knife(®). Surgery was performed for 35min, with 70 watts for cutting and 50 watts for coagulation, resecting and evacuating en bloc the bladder tumour, which macroscopically included the muscle layer of the bladder. There were no complications. The technique of en bloc bladder tumour resection with Hybrid Knife(®) is an effective alternative to bipolar loop transurethral resection. Resection with a Hybrid Knife(®) is a procedure with little bleeding and good surgical vision and minimises the risk of bladder perforation and tumour implants. The procedure facilitates determining the positivity of the neoplastic process, vascular infiltration and bladder muscle invasion in the histopathology study. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. The 2016 WHO Classification of Tumours of the Urinary System and Male Genital Organs-Part A: Renal, Penile, and Testicular Tumours.

    Science.gov (United States)

    Moch, Holger; Cubilla, Antonio L; Humphrey, Peter A; Reuter, Victor E; Ulbright, Thomas M

    2016-07-01

    The fourth edition of the World Health Organization (WHO) classification of urogenital tumours (WHO "blue book"), published in 2016, contains significant revisions. These revisions were performed after consideration by a large international group of pathologists with special expertise in this area. A subgroup of these persons met at the WHO Consensus Conference in Zurich, Switzerland, in 2015 to finalize the revisions. This review summarizes the most significant differences between the newly published classification and the prior version for renal, penile, and testicular tumours. Newly recognized epithelial renal tumours are hereditary leiomyomatosis and renal cell carcinoma (RCC) syndrome-associated RCC, succinate dehydrogenase-deficient RCC, tubulocystic RCC, acquired cystic disease-associated RCC, and clear cell papillary RCC. The WHO/International Society of Urological Pathology renal tumour grading system was recommended, and the definition of renal papillary adenoma was modified. The new WHO classification of penile squamous cell carcinomas is based on the presence of human papillomavirus and defines histologic subtypes accordingly. Germ cell neoplasia in situ (GCNIS) of the testis is the WHO-recommended term for precursor lesions of invasive germ cell tumours, and testicular germ cell tumours are now separated into two fundamentally different groups: those derived from GCNIS and those unrelated to GCNIS. Spermatocytic seminoma has been designated as a spermatocytic tumour and placed within the group of non-GCNIS-related tumours in the 2016 WHO classification. The 2016 World Health Organization (WHO) classification contains new renal tumour entities. The classification of penile squamous cell carcinomas is based on the presence of human papillomavirus. Germ cell neoplasia in situ of the testis is the WHO-recommended term for precursor lesions of invasive germ cell tumours. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All

  8. Tumour-associated microglia/macrophages predict poor prognosis in high-grade gliomas and correlate with an aggressive tumour subtype

    DEFF Research Database (Denmark)

    Sørensen, M D; Dahlrot, R H; Boldt, H B

    2018-01-01

    AIMS: Glioblastomas are highly aggressive and treatment resistant. Increasing evidence suggests that tumour-associated macrophages/microglia (TAMs) facilitate tumour progression by acquiring a M2-like phenotype. Our objective was to investigate the prognostic value of TAMs in gliomas using...... automated quantitative double immunofluorescence. METHODS: Samples from 240 patients with primary glioma were stained with antibodies against ionized calcium-binding adaptor molecule-1 (IBA-1) and cluster of differentiation 204 (CD204) to detect TAMs and M2-like TAMs. The expression levels were quantified...... by software-based classifiers. The associations between TAMs, gemistocytic cells and glioblastoma subtype were examined with immuno- and haematoxylin-eosin stainings. Three tissue arrays containing glioblastoma specimens were included to study IBA-1/CD204 levels in central tumour and tumour periphery...

  9. The differential impact of microsatellite instability as a marker of prognosis and tumour response between colon cancer and rectal cancer.

    Science.gov (United States)

    Hong, Sung Pil; Min, Byung So; Kim, Tae Il; Cheon, Jae Hee; Kim, Nam Kyu; Kim, Hoguen; Kim, Won Ho

    2012-05-01

    Microsatellite instability (MSI) is a distinct molecular phenotype of colorectal cancer related to prognosis and tumour response to 5-fluorouracil (5-FU)-based chemotherapy. We investigated the differential impact of MSI between colon and rectal cancers as a marker of prognosis and chemotherapeutic response. PCR-based MSI assay was performed on 1125 patients. Six hundred and sixty patients (58.7%) had colon cancer and 465 patients (41.3%) had rectal cancer. Among 1125 patients, 106 (9.4%) had high-frequency MSI (MSI-H) tumours. MSI-H colon cancers (13%) had distinct phenotypes including young age at diagnosis, family history of colorectal cancer, early Tumor, Node, Metastasis (TNM) stage, proximal location, poor differentiation, and high level of baseline carcinoembryonic antigen (CEA), while MSI-H rectal cancers (4.3%) showed similar clinicopathological characteristics to MSS/MSI-L tumours except for family history of colorectal cancer. MSI-H tumours were strongly correlated with longer disease free survival (DFS) (P=0.005) and overall survival (OS) (P=0.009) than MSS/MSI-L tumours in colon cancer, while these positive correlations were not observed in rectal cancers. The patients with MSS/MSI-L tumours receiving 5-FU-based chemotherapy showed good prognosis (P=0.013), but this positive association was not observed in MSI-H (P=0.104). These results support the use of MSI status as a marker of prognosis and response to 5-FU-based chemotherapy in patients with colon cancers. Further study is mandatory to evaluate the precise role of MSI in patients with rectal cancers and the effect of 5-FU-based chemotherapy in MSI-H tumours. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Determination of acquisition frequency for intrafractional motion of pancreas in CyberKnife radiotherapy.

    Science.gov (United States)

    Zhang, Huailing; Zhao, Guoru; Djajaputra, David; Xie, Yaoqin

    2014-01-01

    To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval) and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

  11. Haematogenous tumour growth in the inferior vena cava in a patient with a nonseminomatous testicular tumour

    NARCIS (Netherlands)

    Ham, S J; Koops, H Schraffordt; Sleijfer, D T; Freling, N M; Molenaar, W M

    1991-01-01

    The case history is reported of a patient with an invasion of the inferior vena cava by metastases of a non-seminomatous testicular tumour. He was treated with combination chemotherapy, followed by laparotomy and resection of residual tumour tissue. Fourteen months after this operation he is in good

  12. Primary Central Nervous System Tumours in Children and ...

    African Journals Online (AJOL)

    Primary CNS tumours are the commonest childhood solid tumours in most developed countries, accounting for 25-30% of cases. In our environment they occur less frequently. These tumours are nonetheless the cause of significant morbidity and mortality in the paediatric age group worldwide. However paediatric CNS ...

  13. Primitive neuroectodermal tumour of the kidney: radiologic-pathological correlations.

    Science.gov (United States)

    Chea, Y W; Agrawal, Rashi; Poh, Angeline C C

    2008-06-01

    A primitive neuroectodermal tumour of the kidney is a rare malignancy. We report the computed tomographic features and the histopathological correlation of such a tumour occurring in a middle-aged man. Although the radiological appearance has significant overlap with other renal tumours, this tumour should be included in the differential diagnosis of a large renal mass in younger patients.

  14. Ovarian yolk sac tumour in a girl - case report.

    Science.gov (United States)

    Sharma, Charu; Shah, Hemanshi; Sisodiya Shenoy, Neha; Makhija, Deepa; Waghmare, Mukta

    2017-01-01

    Yolk sac tumours are rare ovarian malignancies accounting for less than 1% of malignant ovarian germ cell tumours. They are mostly seen in adolescents and young women and are usually unilateral making fertility preservation imperative. Raised alpha-feto protein level is the hallmark of this tumour. We describe stage III yolk sac tumour in a girl child.

  15. Positron emission tomography (PET) and pancreatic tumours

    International Nuclear Information System (INIS)

    Montravers, F.; Kerrou, K.; Grahek, D.; Gutman, F.; Beco, V. de; Talbot, J.N.

    2005-01-01

    Neoplasms of the pancreas may originate front both exocrine and endocrine cells but in 90% of the cases, they correspond to ductal adenocarcinomas. For adenocarcinomas, the major indication of FDG-PET corresponds to the pre-operative staging because unexpected distant metastases can be detected by FDG-PET in about 20 to 40% of the cases, which results in avoidance of unnecessary surgical procedures. FDG PET is also useful in evaluation of the treatment effect, monitoring after the operation and detection of recurrent pancreatic cancers. For the characterisation of the pancreatic tumour, the performance of FDG-PET is sometimes limited due to poor cellularity, hyperglycemia or inflammatory processes. especially for large tumours and is indicated only in cases of doubtful results of CT or MRI. For endocrine pancreatic tumours, FDG-PET is useful only in case of poorly-differentiated and aggressive tumours. F-DOPA PET can he useful, complementary to pentetreotide scintigraphy, in well-differentiated endocrine tumours. (authors)

  16. Pathology of Neuroendocrine Tumours of the Female Genital Tract.

    Science.gov (United States)

    Howitt, Brooke E; Kelly, Paul; McCluggage, W Glenn

    2017-09-01

    Neuroendocrine tumours are uncommon or rare at all sites in the female genital tract. The 2014 World Health Organisation (WHO) Classification of neuroendocrine tumours of the endometrium, cervix, vagina and vulva has been updated with adoption of the terms low-grade neuroendocrine tumour and high-grade neuroendocrine carcinoma. In the endometrium and cervix, high-grade neoplasms are much more prevalent than low-grade and are more common in the cervix than the corpus. In the ovary, low-grade tumours are more common than high-grade carcinomas and the term carcinoid tumour is still used in WHO 2014. The term ovarian small-cell carcinoma of pulmonary type is included in WHO 2014 for a tumour which in other organs is termed high small-cell neuroendocrine carcinoma. Neuroendocrine tumours at various sites within the female genital tract often occur in association with other neoplasms and more uncommonly in pure form.

  17. FDG PET imaging of Ela1-myc mice reveals major biological differences between pancreatic acinar and ductal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Abasolo, Ibane [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Universitat Pompeu Fabra, Parc de Recerca Biomedica de Barcelona, Departament de Ciencies Experimentals i de la Salut, Barcelona (Spain); Institut d' Alta Tecnologia - CRC, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Pujal, Judit; Navarro, Pilar [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Rabanal, Rosa M.; Serafin, Anna [Universitat Autonoma de Barcelona, Departament de Medicina i Cirurgia Animals, Barcelona (Spain); Millan, Olga [Institut d' Alta Tecnologia - CRC, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Real, Francisco X. [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Universitat Pompeu Fabra, Parc de Recerca Biomedica de Barcelona, Departament de Ciencies Experimentals i de la Salut, Barcelona (Spain); Programa de Patologia Molecular, Centro Nacional de Investigaciones Oncologicas, Madrid (Spain)

    2009-07-15

    The aim was to evaluate FDG PET imaging in Ela1-myc mice, a pancreatic cancer model resulting in the development of tumours with either acinar or mixed acinar-ductal phenotype. Transversal and longitudinal FDG PET studies were conducted; selected tissue samples were subjected to autoradiography and ex vivo organ counting. Glucose transporter and hexokinase mRNA expression was analysed by quantitative reverse transcription polymerase chain reaction (RT-PCR); Glut2 expression was analysed by immunohistochemistry. Transversal studies showed that mixed acinar-ductal tumours could be identified by FDG PET several weeks before they could be detected by hand palpation. Longitudinal studies revealed that ductal - but not acinar - tumours could be detected by FDG PET. Autoradiographic analysis confirmed that tumour areas with ductal differentiation incorporated more FDG than areas displaying acinar differentiation. Ex vivo radioactivity measurements showed that tumours of solely acinar phenotype incorporated more FDG than pancreata of non-transgenic littermates despite the fact that they did not yield positive PET images. To gain insight into the biological basis of the differential FDG uptake, glucose transporter and hexokinase transcript expression was studied in microdissected tumour areas enriched for acinar or ductal cells and validated using cell-specific markers. Glut2 and hexokinase I and II mRNA levels were up to 20-fold higher in ductal than in acinar tumours. Besides, Glut2 protein overexpression was found in ductal neoplastic cells but not in the surrounding stroma. In Ela1-myc mice, ductal tumours incorporate significantly more FDG than acinar tumours. This difference likely results from differential expression of Glut2 and hexokinases. These findings reveal previously unreported biological differences between acinar and ductal pancreatic tumours. (orig.)

  18. FDG PET imaging of Ela1-myc mice reveals major biological differences between pancreatic acinar and ductal tumours

    International Nuclear Information System (INIS)

    Abasolo, Ibane; Pujal, Judit; Navarro, Pilar; Rabanal, Rosa M.; Serafin, Anna; Millan, Olga; Real, Francisco X.

    2009-01-01

    The aim was to evaluate FDG PET imaging in Ela1-myc mice, a pancreatic cancer model resulting in the development of tumours with either acinar or mixed acinar-ductal phenotype. Transversal and longitudinal FDG PET studies were conducted; selected tissue samples were subjected to autoradiography and ex vivo organ counting. Glucose transporter and hexokinase mRNA expression was analysed by quantitative reverse transcription polymerase chain reaction (RT-PCR); Glut2 expression was analysed by immunohistochemistry. Transversal studies showed that mixed acinar-ductal tumours could be identified by FDG PET several weeks before they could be detected by hand palpation. Longitudinal studies revealed that ductal - but not acinar - tumours could be detected by FDG PET. Autoradiographic analysis confirmed that tumour areas with ductal differentiation incorporated more FDG than areas displaying acinar differentiation. Ex vivo radioactivity measurements showed that tumours of solely acinar phenotype incorporated more FDG than pancreata of non-transgenic littermates despite the fact that they did not yield positive PET images. To gain insight into the biological basis of the differential FDG uptake, glucose transporter and hexokinase transcript expression was studied in microdissected tumour areas enriched for acinar or ductal cells and validated using cell-specific markers. Glut2 and hexokinase I and II mRNA levels were up to 20-fold higher in ductal than in acinar tumours. Besides, Glut2 protein overexpression was found in ductal neoplastic cells but not in the surrounding stroma. In Ela1-myc mice, ductal tumours incorporate significantly more FDG than acinar tumours. This difference likely results from differential expression of Glut2 and hexokinases. These findings reveal previously unreported biological differences between acinar and ductal pancreatic tumours. (orig.)

  19. Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation

    Directory of Open Access Journals (Sweden)

    Guo Xiao-Mao

    2010-10-01

    .1 mm and 12.7 mm in the AP direction, respectively. Conclusions Residual and intrafractional errors can significantly affect the accuracy of image-guided APBI with nonplanar 3DCRT techniques. If a 10-mm CTV-PTV margin is applied, a correction action level of 5 mm or less is necessary so as to maintain the RAIF errors within 10 mm for more than 95% of fractions. Pre-treatment CBCT guidance is not a guarantee for safe delivery of the treatment despite its known benefits of reducing the initial setup errors. A patient position verification and correction during the treatment may be a method for the safe delivery.

  20. Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Cai, Gang; Hu, Wei-Gang; Chen, Jia-Yi; Yu, Xiao-Li; Pan, Zi-Qiang; Yang, Zhao-Zhi; Guo, Xiao-Mao; Shao, Zhi-Min; Jiang, Guo-Liang

    2010-01-01

    , respectively. Residual and intrafractional errors can significantly affect the accuracy of image-guided APBI with nonplanar 3DCRT techniques. If a 10-mm CTV-PTV margin is applied, a correction action level of 5 mm or less is necessary so as to maintain the RAIF errors within 10 mm for more than 95% of fractions. Pre-treatment CBCT guidance is not a guarantee for safe delivery of the treatment despite its known benefits of reducing the initial setup errors. A patient position verification and correction during the treatment may be a method for the safe delivery

  1. Intra-tumour IgA1 is common in cancer and is correlated with poor prognosis in bladder cancer.

    Directory of Open Access Journals (Sweden)

    Charlotte Welinder

    2016-08-01

    Full Text Available A high frequency of IgA1-positive tumour cells was found in tissue micro-arrays of oesophagus, colon, testis, lung, breast, bladder and ovarian cancer. IgA1 was observed in the cytoplasm and the plasma membrane. A correlation was found between intra-tumour IgA1 and poor overall survival in a large cohort of bladder cancer patients (n = 99, p = 0.011, log-rank test. The number of IgA1-positive tumour cells was also found to be higher in female than male bladder cancer patients. The presence of IgA1 was confirmed in formalin-fixed paraffin-embedded ovarian carcinoma samples using LC-MS/MS analysis. Uptake of IgA1 was also observed in breast cancer and melanoma cell lines when cultivated in the presence of serum from healthy individuals, indicating a possible origin of the IgA1 antibodies in cancer cells.

  2. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  3. Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours

    International Nuclear Information System (INIS)

    Ertl, A.; Schoeggl, A.; Zehetmayer, M.; Kindl, P.; Hartl, R.

    1997-01-01

    Between March 1993 and January 1997, stereotactic radiation techniques were used to irradiate 66 intraocular tumour patients with the Gamma Knife (Leksell Gamma Knife, model B unit) at the University of Vienna, Austria. This study investigates the dosimetry for stereotactic irradiation of ocular structures. For the dosimetry program KULA 4.4, Gamma Knife stereotactic irradiation of the eye represents an extreme frontal skull position. In addition, irradiation of the eye may be performed in the usual supine position in exceptional cases only. With the patient in the prone position, the dose planning program has to calculate with a significantly large number of single-beam extrapolations. In our first experiment we measured the isocentre dose for eight different γ-angle positions, both in prone and supine positions, using TLD measurements in an Alderson head phantom. We found a maximum deviation of ±1.6% using these individually calibrated TLDs. In the second experiment we examined the dose cross profiles for the two most frequently used treatment positions (supine position, γ = 65 deg., and prone position, γ = 140 deg.). For this purpose we implanted a specially designed TLD array into the orbit of a human cadaver head. We found excellent agreement of the dose values measured for the isocentre as well as the posterior part of the eye with orbit with deviations of less than -2.7%. However, for the anterior part of the eye, deviations between computer-generated calculations and the TLD measurements were found to range up to -30%. These differences were noticed both for supine and prone positions. For the Gamma Knife stereotactic irradiation of ocular tumours or pathologies, precautions should be taken to avoid significant underdosage in the anterior part of the radiation field. (author)

  4. Irradiation-induced tumours of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Aanesen, J P; Olofsson, J [Linkoepings Hoegskola (Sweden)

    1979-09-01

    Though irradiation-induced tumours are uncommon, they represent a well defined entity. At this Hospital, 14 irradiation-induced head and neck tumours were encountered in 11 patients over a 10-year period. The irradiation had been given for tuberculous lymphadenitis in 6 of the patients, for lupus vulgaris in one, and thyrotoxicosis in another; the other 3 patients had received radiotherapy for malignant tumours. The interval between the treatment and the diagnosis of the tumour disease ranged from 9 to 48 years (mean 32). Three of the patients had multiple tumours. In view of the risk of cancer-albeit a small one-associated with radiological diagnosis and radiotherapy, these should be performed only on strict indications, expecially in young patients.

  5. Regression of sporadic intra-abdominal desmoid tumour following administration of non-steroidal anti-inflammatory drug

    Directory of Open Access Journals (Sweden)

    Fujiwara Yoshinori

    2008-02-01

    Full Text Available Abstract Background Desmoid tumours or fibromatoses are rare entities characterized by the benign proliferation of fibroblasts, which can be life-threatening due to their locally aggressive properties. Surgery is widely accepted as the first line of treatment for extra-abdominal desmoids; however, it is not recommended for intra-abdominal desmoids because of the high-risk of recurrence and difficulties with the operation. Here, we report on a patient with sporadic intra-abdominal desmoid tumours, who showed partial response following the intake of non-steroidal anti-inflammatory drugs. Case presentation A 73-year-old man presented with swelling and pain of the right leg. Computed tomography showed an abnormal multilocular soft-tissue mass (95 × 70 mm in the right pelvis, which was revealed by biopsy to be a desmoid tumour. Immunohistochemical analysis showed that the tumour cells expressed vimentin, but not smooth-muscle actin, CD34, or desmin. Very few Ki-67-positive cells were found. Non-cytotoxic treatment with etodolac (200 mg/day was chosen because of the patient's age, lack of bowel obstruction, and the likelihood of prostate cancer. Two years after the commencement of non-steroidal anti-inflammatory drug administration, computed tomography showed a decrease in tumour size (63 × 49 mm, and the disappearance of intratumoural septa. Conclusion Our case report suggests that non-steroidal anti-inflammatory drug treatment should be taken into consideration for use as first-line treatment in patients with sporadic intra-abdominal desmoid tumours.

  6. Regression of sporadic intra-abdominal desmoid tumour following administration of non-steroidal anti-inflammatory drug

    Science.gov (United States)

    Tanaka, Keita; Yoshikawa, Reigetsu; Yanagi, Hidenori; Gega, Makoto; Fujiwara, Yoshinori; Hashimoto-Tamaoki, Tomoko; Hirota, Syozo; Tsujimura, Tohru; Tomita, Naohiro

    2008-01-01

    Background Desmoid tumours or fibromatoses are rare entities characterized by the benign proliferation of fibroblasts, which can be life-threatening due to their locally aggressive properties. Surgery is widely accepted as the first line of treatment for extra-abdominal desmoids; however, it is not recommended for intra-abdominal desmoids because of the high-risk of recurrence and difficulties with the operation. Here, we report on a patient with sporadic intra-abdominal desmoid tumours, who showed partial response following the intake of non-steroidal anti-inflammatory drugs. Case presentation A 73-year-old man presented with swelling and pain of the right leg. Computed tomography showed an abnormal multilocular soft-tissue mass (95 × 70 mm) in the right pelvis, which was revealed by biopsy to be a desmoid tumour. Immunohistochemical analysis showed that the tumour cells expressed vimentin, but not smooth-muscle actin, CD34, or desmin. Very few Ki-67-positive cells were found. Non-cytotoxic treatment with etodolac (200 mg/day) was chosen because of the patient's age, lack of bowel obstruction, and the likelihood of prostate cancer. Two years after the commencement of non-steroidal anti-inflammatory drug administration, computed tomography showed a decrease in tumour size (63 × 49 mm), and the disappearance of intratumoural septa. Conclusion Our case report suggests that non-steroidal anti-inflammatory drug treatment should be taken into consideration for use as first-line treatment in patients with sporadic intra-abdominal desmoid tumours. PMID:18257933

  7. Skull base tumours

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Instituto Portugues de Oncologia Francisco Gentil, Servico de Radiologia, Rua Professor Lima Basto, 1093 Lisboa Codex (Portugal)], E-mail: borgesalexandra@clix.pt

    2008-06-15

    With the advances of cross-sectional imaging radiologists gained an increasing responsibility in the management of patients with skull base pathology. As this anatomic area is hidden to clinical exam, surgeons and radiation oncologists have to rely on imaging studies to plan the most adequate treatment. To fulfil these endeavour radiologists need to be knowledgeable about skull base anatomy, about the main treatment options available, their indications and contra-indications and needs to be aware of the wide gamut of pathologies seen in this anatomic region. This article will provide a radiologists' friendly approach to the central skull base and will review the most common central skull base tumours and tumours intrinsic to the bony skull base.

  8. Skull base tumours

    International Nuclear Information System (INIS)

    Borges, Alexandra

    2008-01-01

    With the advances of cross-sectional imaging radiologists gained an increasing responsibility in the management of patients with skull base pathology. As this anatomic area is hidden to clinical exam, surgeons and radiation oncologists have to rely on imaging studies to plan the most adequate treatment. To fulfil these endeavour radiologists need to be knowledgeable about skull base anatomy, about the main treatment options available, their indications and contra-indications and needs to be aware of the wide gamut of pathologies seen in this anatomic region. This article will provide a radiologists' friendly approach to the central skull base and will review the most common central skull base tumours and tumours intrinsic to the bony skull base

  9. Discrimination of paediatric brain tumours using apparent diffusion coefficient histograms

    International Nuclear Information System (INIS)

    Bull, Jonathan G.; Clark, Christopher A.; Saunders, Dawn E.

    2012-01-01

    To determine if histograms of apparent diffusion coefficients (ADC) can be used to differentiate paediatric brain tumours. Imaging of histologically confirmed tumours with pre-operative ADC maps were reviewed (54 cases, 32 male, mean age 6.1 years; range 0.1-15.8 years) comprising 6 groups. Whole tumour ADC histograms were calculated; normalised for volume. Stepwise logistic regression analysis was used to differentiate tumour types using histogram metrics, initially for all groups and then for specific subsets. All 6 groups (5 dysembryoplastic neuroectodermal tumours, 22 primitive neuroectodermal tumours (PNET), 5 ependymomas, 7 choroid plexus papillomas, 4 atypical teratoid rhabdoid tumours (ATRT) and 9 juvenile pilocytic astrocytomas (JPA)) were compared. 74% (40/54) were correctly classified using logistic regression of ADC histogram parameters. In the analysis of posterior fossa tumours, 80% of ependymomas, 100% of astrocytomas and 94% of PNET-medulloblastoma were classified correctly. All PNETs were discriminated from ATRTs (22 PNET and 4 supratentorial ATRTs) (100%). ADC histograms are useful in differentiating paediatric brain tumours, in particular, the common posterior fossa tumours of childhood. PNETs were differentiated from supratentorial ATRTs, in all cases, which has important implications in terms of clinical management. (orig.)

  10. Augmented reality in bone tumour resection

    Science.gov (United States)

    Park, Y. K.; Gupta, S.; Yoon, C.; Han, I.; Kim, H-S.; Choi, H.; Hong, J.

    2017-01-01

    Objectives We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. Methods We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. Results The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137–143. PMID:28258117

  11. Histopathological review of breast tumours in children and ...

    African Journals Online (AJOL)

    ... of all tumours followed by tubular adenoma (n = 11; 8.2%) and adenosis (n = 10; 7.4%). No case of malignancy was recorded in this study. Conclusion: Fibroadenoma is the most common breast tumour in children and adolescents in our environment. Key words: Adolescents, breast tumours, childhood, fi broadenoma ...

  12. Paediatric laryngeal granular cell tumour

    Directory of Open Access Journals (Sweden)

    Dauda Ayuba

    2009-01-01

    Full Text Available Granular cell tumour (GCT affecting the larynx is not common, especially in children. Most cases are apt to be confused with respiratory papilloma and may even be mistaken for a malignant neoplasia. We present a case of laryngeal GCT in a 12-year-old child to emphasize that the tumour should be regarded in the differential of growths affecting the larynx in children.

  13. Increased FOXP3 expression in tumour-associated tissues of horses affected with equine sarcoid disease.

    Science.gov (United States)

    Mählmann, K; Hamza, E; Marti, E; Dolf, G; Klukowska, J; Gerber, V; Koch, C

    2014-12-01

    Recent studies suggest that regulatory T cells (Tregs) are associated with disease severity and progression in papilloma virus induced neoplasia. Bovine papilloma virus (BPV) is recognised as the most important aetiological factor in equine sarcoid (ES) disease. The aim of this study was to compare expression levels of Treg markers and associated cytokines in tissue samples of ES-affected equids with skin samples of healthy control horses. Eleven ES-affected, and 12 healthy horses were included in the study. Expression levels of forkhead box protein 3 (FOXP3), interleukin 10 (IL10), interleukin 4 (IL4) and interferon gamma (IFNG) mRNA in lesional and tumour-distant samples from ES-affected horses, as well as in dermal samples of healthy control horses were measured using quantitative reverse transcription polymerase chain reaction (PCR). Expression levels were compared between lesional and tumour-distant as well as between tumour-distant and control samples. Furthermore, BPV-1 E5 DNA in samples of ES-affected horses was quantified using quantitative PCR, and possible associations of viral load, disease severity and gene expression levels were evaluated. Expression levels of FOXP3, IL10 and IFNG mRNA and BPV-1 E5 copy numbers were significantly increased in lesional compared to tumour-distant samples. There was no difference in FOXP3 and cytokine expression in tumour-distant samples from ES- compared with control horses. In tumour-distant samples viral load was positively correlated with IL10 expression and severity score. The increased expression of Treg markers in tumour-associated tissues of ES-affected equids indicates a local, Treg-induced immune suppression. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Prostate stereotactic body radiotherapy with simultaneous integrated boost: which is the best planning method?

    International Nuclear Information System (INIS)

    Tree, Alison; Jones, Caroline; Sohaib, Aslam; Khoo, Vincent; As, Nicholas van

    2013-01-01

    The delivery of a simultaneous integrated boost to the intra-prostatic tumour nodule may improve local control. The ability to deliver such treatments with hypofractionated SBRT was attempted using RapidArc (Varian Medical systems, Palo Alto, CA) and Multiplan (Accuray inc, Sunnyvale, CA). 15 patients with dominant prostate nodules had RapidArc and Multiplan plans created using a 5 mm isotropic margin, except 3 mm posteriorly, aiming to deliver 47.5 Gy in 5 fractions to the boost whilst treating the whole prostate to 36.25 Gy in 5 fractions. An additional RapidArc plan was created using an 8 mm isotropic margin, except 5 mm posteriorly, to account for lack of intrafraction tracking. Both RapidArc and Multiplan can produce clinically acceptable boost plans to a dose of 47.5 Gy in 5 fractions. The mean rectal doses were lower for RapidArc plans (D50 13.2 Gy vs 15.5 Gy) but the number of missed constraints was the same for both planning methods (11/75). When the margin was increased to 8 mm/5 mm for the RapidArc plans to account for intrafraction motion, 37/75 constraints were missed. RapidArc and Multiplan can produce clinically acceptable simultaneous integrated boost plans, but the mean rectal D50 and D20 with RapidArc are lower. If the margins are increased to account for intrafraction motion, the RapidArc plans exceed at least one dose constraint in 13/15 cases. Delivering a simultaneous boost with hypofractionation appears feasible, but requires small margins needing intrafraction motion tracking

  15. The potential role of cyclooxygenase-2 inhibitors in the treatment of experimentally-induced mammary tumour: does celecoxib enhance the anti-tumour activity of doxorubicin?

    Science.gov (United States)

    Awara, Wageh M; El-Sisi, Alaa E; El-Sayad, Magda E; Goda, Ahmed E

    2004-11-01

    The potential anti-tumour activity of non-steroidal anti-inflammatory drugs (NSAIDS) has been previously discussed. This study was undertaken to assess the possible anti-tumour activity of the cyclooxygenase-2 (COX-2) inhibitor; celecoxib in an animal model of mammary carcinoma; the solid Ehrlich carcinoma (SEC). The possibility that celecoxib may modulate the anti-tumour activity of doxorubicin on the SEC was also studied. Some of the possible mechanisms underlying such modulation were investigated. The anti-tumour activity of celecoxib (25 mg kg(-1)), diclofenac (12.5 mg kg(-1)) and doxorubicin (2 mg kg(-1)) either alone or in combination were investigated on SEC in vivo through the assessment of tumour growth delay (TGD) and tumour volume (TV), changes in tumour DNA content and nitric oxide (NO) levels, immunohistochemical staining of the tumour suppressor gene product; p53 histopathological examination and determination of apoptotic index of SEC. In addition, the influence of these drugs on the DNA fragmentation pattern of Ehrlich carcinoma cells (ECC) was studied. It was found that both celecoxib and diclofenac lack the anti-tumour activity on SEC. In addition there was a significant increase in doxorubicin anti-tumour activity when administered in combination with celecoxib. Moreover, it was found that both celecoxib and diclofenac have the potential to inhibit the function of P-glycoprotein (P-gp) in ECC using rhodamine uptake and efflux assays. Therefore, the current study suggested the chemosensitizing potential of celecoxib in the SEC animal model of mammary tumour, which could be explained in part on the basis of inhibition of P-gp function, with possible enhancement of doxorubicin anti-tumour activity.

  16. Tumour cell expansion in bladder epithelium

    NARCIS (Netherlands)

    J.M.J. Rebel (Annemarie)

    1995-01-01

    textabstractBladder cancer is common in western society. The major problem of patients with superficial bladder cancer is the high recurrence rate and multifocality of these tumours. In 70 % of the patients superficial bladder cancer recurs after local resection of the tumour within 15 years. The

  17. Accuracy and role of contrast-enhanced CT in diagnosis and surgical planning in 88 soft tissue tumours of extremities

    International Nuclear Information System (INIS)

    Verga, Lucia; Robiati, Sara; De Marchi, Armanda; Martorano, Domenico; Faletti, Carlo; Brach del Prever, Elena Maria; Linari, Alessandra; Boffano, Michele; Piana, Raimondo

    2016-01-01

    Soft tissue tumours (STT) require accurate diagnosis in order to identify potential malignancies. Preoperative planning is fundamental to avoid inadequate treatments. The role of contrast-enhanced computed tomography (CT) for local staging remains incompletely assessed. Aims of the study were to evaluate CT accuracy in discriminating active from aggressive tumours compared to histology and evaluate the role of CT angiography (CTA) in surgical planning. This retrospective cohort series of 88 cases from 1200 patients (7 %) was locally studied by contrast-enhanced CT and CTA in a referral centre: 74 malignant tumours, 14 benign lesions. Contrast-enhancement patterns and relationship of the mass with major vessels and bone were compared with histology on surgically excised samples. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were evaluated in discriminating active from aggressive tumours. Sensitivity in differentiating aggressive tumours from active lesions was 89 %, specificity 84 %, PPV 90 %, NPV 82 %. The relationship between mass and major vessels/bone was fundamental for surgical strategy respectively in 40 % and in 58 % of malignant tumours. Contrast-enhanced CT and CTA are effective in differentiating aggressive masses from active lesions in soft tissue and in depicting the relationship between tumour and adjacent bones and major vessels. (orig.)

  18. The mechanism of 67Ga uptake in animal and human tumours

    International Nuclear Information System (INIS)

    Hammersley, P.A.G.; Cronshaw, S.; Taylor, D.M.; Kernforschungszentrum Karlsruhe G.m.b.H.

    1980-01-01

    The subcellular distribution of 67 Ga has been studied by differential centrifugation in 3 transplantable mouse tumours, 3 transplantable rat tumours, 1 dog tumour, 3 human tumour xenografts and 2 human tumours in situ at various times after injection of the citrate complex. From 24 h post injection the nuclide was located predominantly in lysosomal structures in all the tumours studied. Studies in two murine tumours showed marked differences in the rate of lysosomal accumulation of 67 Ga. In the ADJ/PC6 plasmacytoma lysosomal uptake of 67 Ga had reached a plateau within 15 min while in the S180 tumour lysosomal accumulation of the nuclide occurred over the first 24 h. Normal mouse liver showed a similar pattern to this latter tumour. It is postulated that these variations in the rate of lysosomal accumulation of 67 Ga reflect differences in the permeability of the lysosomal membrane. While large amounts of 67 Ga were found in the crude nuclear fraction of some tumours this was attributed to unbroken cells as studies with purified nuclei from 7 different tumours indicated that between 2 and 14% of the total tumour 67 Ga was associated with the nuclei. (orig.)

  19. Tumour-associated microglia/macrophages predict poor prognosis in high-grade gliomas and correlate with an aggressive tumour subtype

    DEFF Research Database (Denmark)

    Sørensen, M D; Dahlrot, R H; Boldt, H B

    2018-01-01

    (+) TAMs co-expressed proteins related to tumour aggressiveness including matrix metallopeptidase-14 and hypoxia-inducible factor-1α. CONCLUSIONS: This is the first study to use automated quantitative immunofluorescence to determine the prognostic impact of TAMs. Our results suggest that M2-like TAMs hold......AIMS: Glioblastomas are highly aggressive and treatment resistant. Increasing evidence suggests that tumour-associated macrophages/microglia (TAMs) facilitate tumour progression by acquiring a M2-like phenotype. Our objective was to investigate the prognostic value of TAMs in gliomas using...

  20. The hypoxic tumour cell in radiation therapy

    International Nuclear Information System (INIS)

    Trott, K.R.; Gesellschaft fuer Strahlen- und Umweltforschung m.b.H., Neuherberg/Muenchen

    1976-01-01

    In most tumours there is a disproportion between the tumour cells and vascular connective tissue. A lack of oxygen depending on extent and duration, leads to changes of the metabolism and of the proliferative properties of the cells, to an increase of radiation resistance and to a reduction of the ability to recover from radiation injuries. Finally with longer duration, hypoxy leads to cell killing. As a result of irradiation, a reoxygenation of a part of the previous hypoxic tumour cell occurs more or less quickly. The time and topographic changes of these factors are involved in a complex manner in the radiotherapy of malignant tumours and essentially share the responsibility regarding the curative success of radiotherapy. (orig./LH) [de

  1. New tumour entities in the 4th edition of the World Health Organization Classification of Head and Neck tumours: odontogenic and maxillofacial bone tumours.

    Science.gov (United States)

    Speight, Paul M; Takata, Takashi

    2018-03-01

    The latest (4th) edition of the World Health Organization Classification of Head and Neck tumours has recently been published with a number of significant changes across all tumour sites. In particular, there has been a major attempt to simplify classifications and to use defining criteria which can be used globally in all situations, avoiding wherever possible the use of complex molecular techniques which may not be affordable or widely available. This review summarises the changes in Chapter 8: Odontogenic and maxillofacial bone lesions. The most significant change is the re-introduction of the classification of the odontogenic cysts, restoring this books status as the only text which classifies and defines the full range of lesions of the odontogenic tissues. The consensus group considered carefully the terminology of lesions and were concerned to ensure that the names used properly reflected the best evidence regarding the true nature of specific entities. For this reason, this new edition restores the odontogenic keratocyst and calcifying odontogenic cyst to the classification of odontogenic cysts and rejects the previous terminology (keratocystic odontogenic tumour and calcifying cystic odontogenic tumour) which were intended to suggest that they are true neoplasms. New entities which have been introduced include the sclerosing odontogenic carcinoma and primordial odontogenic tumour. In addition, some previously poorly defined lesions have been removed, including the ameloblastic fibrodentinoma, ameloblastic fibro-odontoma, which are probably developing odontomas, and the odontoameloblastoma, which is not regarded as an entity. Finally, the terminology "cemento" has been restored to cemento-ossifying fibroma and cemento-osseous dysplasias, to properly reflect that they are of odontogenic origin and are found in the tooth-bearing areas of the jaws.

  2. Delivery of chemotherapeutic drugs in tumour cell-derived microparticles.

    Science.gov (United States)

    Tang, Ke; Zhang, Yi; Zhang, Huafeng; Xu, Pingwei; Liu, Jing; Ma, Jingwei; Lv, Meng; Li, Dapeng; Katirai, Foad; Shen, Guan-Xin; Zhang, Guimei; Feng, Zuo-Hua; Ye, Duyun; Huang, Bo

    2012-01-01

    Cellular microparticles are vesicular plasma membrane fragments with a diameter of 100-1,000 nanometres that are shed by cells in response to various physiological and artificial stimuli. Here we demonstrate that tumour cell-derived microparticles can be used as vectors to deliver chemotherapeutic drugs. We show that tumour cells incubated with chemotherapeutic drugs package these drugs into microparticles, which can be collected and used to effectively kill tumour cells in murine tumour models without typical side effects. We describe several mechanisms involved in this process, including uptake of drug-containing microparticles by tumour cells, synthesis of additional drug-packaging microparticles by these cells that contribute to the cytotoxic effect and the inhibition of drug efflux from tumour cells. This study highlights a novel drug delivery strategy with potential clinical application.

  3. XIAP and Ki-67: A Correlation Between Antiapoptotic and Proliferative Marker Expression in Benign and Malignant Tumours of Salivary Gland: An Immunohistochemical Study.

    Science.gov (United States)

    Bagulkar, Bhupesh Bhayyaji; Gawande, Madhuri; Chaudhary, Minal; Gadbail, Amol Ramchandra; Patil, Swati; Bagulkar, Smita

    2015-02-01

    Impaired balance between cell proliferation and apoptosis is crucial to the development of malignant neoplasm. The purpose of this study was to evaluate and compare the expression of X-Linked inhibitor of apoptotic protein (XIAP) (antiapoptotic marker) and Ki-67 (proliferative marker) expression in benign and malignant salivary gland (SG) tumours. The study consisted of 40 cases of benign SG tumours and 50 cases of malignant SG tumours. The immunohistochemistry was carried out by using Ki-67 antibody (clone MIB-1) and XIAP antibody in all the groups. XIAP expression was significantly higher in malignant SG tumours than benign SG tumours (p = 0.016). Ki-67 LI was significantly higher in malignant SG tumours than benign SG tumours (p = 0.0002). Statistically significant positive correlation between Ki-67 count and XIAP expression was noted in benign and malignant SG tumours (p = 0.000). As the expression of an antiapoptotic marker (XIAP) increases, the expression of a proliferative marker (Ki-67) also increases from benign to malignant SG tumours. Thus, targeted therapy of XIAP may play a future role in the management of SG malignancy.

  4. Primitive neuroectodermal tumour of the kidney with vena caval and atrial tumour thrombus: a case report

    Directory of Open Access Journals (Sweden)

    Ong Poh

    2008-08-01

    Full Text Available Abstract Introduction Renal primitive neuroectodermal tumour is an extremely rare malignancy. Case presentation A 21-year-old woman presented with microscopic haematuria, a palpable right loin mass, dyspnoea, dizziness and fatigue. Initial ultrasound scan of the kidneys revealed an 11 cm right renal mass with venous extension into the inferior vena cava. Computed tomography of the thorax and abdomen revealed an extension of the large renal mass into the right renal vein, inferior vena cava and up to the right atrium. A small paracaval lymph node was noted and three small metastatic nodules were identified within the lung parenchyma. The patient underwent a radical nephrectomy and inferior vena caval tumour (level IV thrombectomy with cardiopulmonary bypass and deep hypothermic circulatory arrest. Immunohistochemical staining of the specimen showed a highly specific cluster of differentiation (CD 99, thus confirming the diagnosis of a primitive neuroectodermal tumour. Conclusion It is important that a renal primitive neuroectodermal tumour be considered, particularly in young patients with a renal mass and extensive thrombus.

  5. [{sup 177}Lu]pertuzumab: experimental studies on targeting of HER-2 positive tumour cells

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Mikael; Gedda, Lars [Uppsala University, Biomedical Radiation Sciences, Rudbeck Laboratory, Uppsala (Sweden); Uppsala University, Experimental Urology, Rudbeck Laboratory, Uppsala (Sweden); Tolmachev, Vladimir; Andersson, Karl; Carlsson, Joergen [Uppsala University, Biomedical Radiation Sciences, Rudbeck Laboratory, Uppsala (Sweden); Sandstroem, Mattias [Uppsala University, Medical Radiation Physics, Uppsala University Hospital, Uppsala (Sweden)

    2005-12-01

    The new antibody pertuzumab (Omnitarg) targets the dimerisation subdomain of HER-2. The purpose of this study was to analyse whether pertuzumab retains HER-2 targeting capacity after labelling with the therapeutically interesting beta emitter {sup 177}Lu and to make initial characterisations in vitro and in vivo. Pertuzumab was conjugated with isothiocyanate-benzyl-CHX-A{sup ''}-DTPA and chelated to {sup 177}Lu. Immunoreactivity, affinity, cellular retention and internalisation were analysed using SKOV-3 cells. The affinity of non-radioactive pertuzumab was measured using a surface plasmon resonance biosensor. In vivo targeting and specific binding were assessed in Balb/c (nu/nu) mice carrying SKOV-3 xenografts. The biodistribution of {sup 177}Lu was determined 1, 3 and 7 days after [{sup 177}Lu]pertuzumab administration. Gamma camera images were taken after 3 days. The immunoreactivity of [{sup 177}Lu]pertuzumab was 85.8{+-}1.3%. The affinity of non-radioactive pertuzumab was 1.8{+-}1.1 nM, and that of [{sup 177}Lu]pertuzumab, 4.1{+-}0.7 nM. The cellular retention after 5 h pre-incubation was 90{+-}2% at 20 h. The targeting was HER-2 specific both in vitro and in vivo, since excess amounts of non-labelled antibody inhibited the uptake of labelled antibody (p<0.0001 and p<0.01, respectively). The biodistribution and gamma camera images of {sup 177}Lu showed extensive tumour uptake. Normal tissues had a surprisingly low uptake. Pertuzumab was efficiently labelled with {sup 177}Lu and showed good intracellular retention and HER-2 specific binding both in vitro and in vivo. The gamma camera images and the biodistribution study gave excellent tumour targeting results. Thus, [{sup 177}Lu]pertuzumab is of interest for further studies aimed at radionuclide therapy. (orig.)

  6. Adenoviral gene transfer of angiostatic ATF-BPTI inhibits tumour growth

    International Nuclear Information System (INIS)

    Lefesvre, Pierre; Attema, Joline; Bekkum, Dirk van

    2002-01-01

    The outgrowth of new vessels – angiogenesis – in the tumour mass is considered to be a limiting factor of tumour growth. To inhibit the matrix lysis that is part of the tumour angiogenesis, we employed the chimeric protein mhATF-BPTI, composed of the receptor binding part of the urokinase (ATF) linked to an inhibitor of plasmin (BPTI). For delivery, recombinant adenovirus encoding the transgene of interest was injected intravenously or locally into the tumour. The anti tumour effect of this compound was compared to that of human endostatin and of mhATF alone in two different rat bronchial carcinomas growing either as subcutaneous implants or as metastases. Significant inhibition of the tumour growth and decrease of the number of lung metastasis was achieved when the concentration of mhATF-BPTI at the tumour site was above 400 of ng / g tissue. This concentration could be achieved via production by the liver, only if permissive to the recombinant adenovirus. When the tumour cells could be transduced, local delivery of the vector was enough to obtain a response. In the case of metastasis, the capacity of the lung tissue to concentrate the encoded protein was essential to reach the required therapeutic levels. Further, endostatin or mhATF could not reproduce the effects of mhATF-BPTI, at similar concentrations (mhATF) and even at 10-fold higher concentration (endostatin). The ATF-BPTI was shown to inhibit tumour growth of different rat lung tumours when critical concentration was reached. In these tumour models, endostatin or ATF induce almost no tumour response

  7. WE-G-BRD-04: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An Integrated Model-Based Intrafractional Organ Motion Tracking Approach with Dynamic MRI in Head and Neck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H; Dolly, S; Anastasio, M; Li, H; Wooten, H; Gay, H; Mutic, S; Thorstad, W; Li, H [Washington University School of Medicine, Saint Louis, MO (United States); Victoria, J; Dempsey, J [ViewRay incorporated, Oakwood Village, Ohio (United States); Ruan, S [University of Rouen, QuantIF - EA 4108 LITIS, Rouen (France); Low, D [Deparment of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (United States)

    2015-06-15

    Purpose: In-treatment dynamic cine images, provided by the first commercially available MRI-guided radiotherapy system, allow physicians to observe intrafractional motion of head and neck (H&N) internal structures. Nevertheless, high anatomical complexity and relatively poor cine image contrast/resolution have complicated automatic intrafractional motion evaluation. We proposed an integrated model-based approach to automatically delineate and analyze moving structures from on-board cine images. Methods: The H&N upper airway, a complex and highly deformable region wherein severe internal motion often occurs, was selected as the target-to-be-tracked. To reliably capture its motion, a hierarchical structure model containing three statistical shapes (face, face-jaw, and face-jaw-palate) was first built from a set of manually delineated shapes using principal component analysis. An integrated model-fitting algorithm was then employed to align the statistical shapes to the first to-be-detected cine frame, and multi-feature level-set contour propagation was performed to identify the airway shape change in the remaining frames. Ninety sagittal cine MR image sets, acquired from three H&N cancer patients, were utilized to demonstrate this approach. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 20 randomly selected images from each patient. The resulting dice similarity coefficient (93.28+/−1.46 %) and margin error (0.49+/−0.12 mm) showed good agreement with the manual results. Intrafractional displacements of anterior, posterior, inferior, and superior airway boundaries were observed, with values of 2.62+/−2.92, 1.78+/−1.43, 3.51+/−3.99, and 0.68+/−0.89 mm, respectively. The H&N airway motion was found to vary across directions, fractions, and patients, and highly correlated with patients’ respiratory frequency. Conclusion: We proposed the integrated computational approach, which for the first

  8. WE-G-BRD-04: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An Integrated Model-Based Intrafractional Organ Motion Tracking Approach with Dynamic MRI in Head and Neck Radiotherapy

    International Nuclear Information System (INIS)

    Chen, H; Dolly, S; Anastasio, M; Li, H; Wooten, H; Gay, H; Mutic, S; Thorstad, W; Li, H; Victoria, J; Dempsey, J; Ruan, S; Low, D

    2015-01-01

    Purpose: In-treatment dynamic cine images, provided by the first commercially available MRI-guided radiotherapy system, allow physicians to observe intrafractional motion of head and neck (H&N) internal structures. Nevertheless, high anatomical complexity and relatively poor cine image contrast/resolution have complicated automatic intrafractional motion evaluation. We proposed an integrated model-based approach to automatically delineate and analyze moving structures from on-board cine images. Methods: The H&N upper airway, a complex and highly deformable region wherein severe internal motion often occurs, was selected as the target-to-be-tracked. To reliably capture its motion, a hierarchical structure model containing three statistical shapes (face, face-jaw, and face-jaw-palate) was first built from a set of manually delineated shapes using principal component analysis. An integrated model-fitting algorithm was then employed to align the statistical shapes to the first to-be-detected cine frame, and multi-feature level-set contour propagation was performed to identify the airway shape change in the remaining frames. Ninety sagittal cine MR image sets, acquired from three H&N cancer patients, were utilized to demonstrate this approach. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 20 randomly selected images from each patient. The resulting dice similarity coefficient (93.28+/−1.46 %) and margin error (0.49+/−0.12 mm) showed good agreement with the manual results. Intrafractional displacements of anterior, posterior, inferior, and superior airway boundaries were observed, with values of 2.62+/−2.92, 1.78+/−1.43, 3.51+/−3.99, and 0.68+/−0.89 mm, respectively. The H&N airway motion was found to vary across directions, fractions, and patients, and highly correlated with patients’ respiratory frequency. Conclusion: We proposed the integrated computational approach, which for the first

  9. Prognostic impact of nomogram based on whole tumour size, tumour disappearance ratio on CT and SUVmax on PET in lung adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Song, So Hee; Lee, Ho Yun; Kim, Eun Young; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Gangnam-Gu, Seoul (Korea, Republic of); Ahn, Joong Hyun [Samsung Biomedical Research Institute, Biostatistics Team, Seoul (Korea, Republic of); Lee, Geewon [Pusan National University Hospital, Pusan National University School of Medicine, Department of Radiology and Medical Research Institute, Busan (Korea, Republic of); Choi, Joon Young [Sungkyunkwan University School of Medicine, Departments of Nuclear Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kang, Jun [Catholic University of Korea, Department of Pathology, Inchun St. Mary' s Hospital, College of Medicine, Inchun (Korea, Republic of); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of); Kwon, O.J. [Sungkyunkwan University School of Medicine, Division of Respiratory and Critical Medicine of the Department of Internal Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Hong Kwan; Choi, Yong Soo; Kim, Jhingook; Shim, Young Mog [Sungkyunkwan University School of Medicine, Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-06-15

    Lung adenocarcinoma frequently manifests as subsolid nodules, and the solid portion and ground-glass-opacity (GGO) portion on CT have different prognostic significance. Therefore, current T descriptor, defined as the whole tumour diameter without discrimination between solid and GGO, is insufficient. We aimed to determine the prognostic significance of solid tumour size and attempt to include prognostic factors such as tumour disappearance rate (TDR) on CT and SUVmax on PET/CT. Five hundred and ninety-five patients with completely resected lung adenocarcinoma were analyzed. We developed a nomogram using whole tumour size, TDR, and SUVmax. External validation was performed in another 102 patients. In patients with tumours measuring ≤2 cm and >2 to 3 cm, disease free survival (DFS) was significantly associated with solid tumour size (P < 0.001), but not with whole tumour size (P = 0.052). Developed nomogram was significantly superior to the conventional T stage (area under the curve of survival ROC; P = 0.013 by net reclassification improvement) in stratification of patient survival. In the external validation group, significant difference was noted in DFS according to proposed T stage (P = 0.009). Nomogram-based T descriptors provide better prediction of survival and assessment of individual risks than conventional T descriptors. (orig.)

  10. The epidemiology of neonatal tumours. Report of an international working group.

    Science.gov (United States)

    Moore, S W; Satgé, D; Sasco, A J; Zimmermann, A; Plaschkes, J

    2003-09-01

    Neonatal tumours occur every 12,500-27,500 live births and comprise 2% of childhood malignancies, but there is little clarity as to their real prevalence, sites of origin and pathological nature as reported series vary. As an entity, neonatal tumours provide a unique window of opportunity to study tumours in which minimal environmental interference has occurred. The majority of tumours present with a mass at birth (e.g., teratomas, neuroblastomas, mesoblastic nephroma, fibromatosis), which are not infrequently identified on antenatal ultrasound. Histologically, teratoma and neuroblastoma remain the two main tumour types encountered with soft tissue sarcoma, renal tumours, CNS tumours and leukaemia being the next most common tumour types identified. Malignant tumours are uncommon in the neonatal period per se and benign tumours may have malignant potential. A particular problem exists in clinical classification, as histological features of malignancy do not always correlate with clinical behaviour. Benign tumours may also be life threatening because of their size and location. Other tumours may demonstrate local invasiveness, but no metastatic potential, and tumours that are clearly malignant may demonstrate unpredictable or uncertain behaviour. Screening programmes have brought more tumours to light, but do not appear to affect the overall prognosis. They may provide clues to the stage at which tumours develop in foetu. The aetiology of cancer in children is multifactorial and includes both genetic and environmental factors. The association between congenital abnormalities and tumours is well established (15% of neonatal tumours). Genetic defects are highly likely in neonatal tumours and include those with a high risk of malignancy (e.g., retinoblastoma), but also genetically determined syndromes with an increased risk of malignancy and complex genetic rearrangements. Tumours are mostly genetically related at a cellular level and factors influencing cellular

  11. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  12. An enhanced heterologous virus-like particle for human papillomavirus type 16 tumour immunotherapy.

    Directory of Open Access Journals (Sweden)

    Khairunadwa Jemon

    Full Text Available Cervical cancer is caused by high-risk, cancer-causing human papillomaviruses (HPV and is the second highest cause of cancer deaths in women globally. The majority of cervical cancers express well-characterized HPV oncogenes, which are potential targets for immunotherapeutic vaccination. Here we develop a rabbit haemorrhagic disease virus (RHDV virus-like particle (VLP-based vaccine designed for immunotherapy against HPV16 positive tumours. An RHDV-VLP, modified to contain the universal helper T cell epitope PADRE and decorated with an MHC I-restricted peptide (aa 48-57 from the HPV16 E6, was tested for its immunotherapeutic efficacy against the TC-1 HPV16 E6 and E7-expressing tumour in mice. The E6-RHDV-VLP-PADRE was administered therapeutically for the treatment of a pre-existing TC-1 tumour and was delivered with antibodies either to deplete regulatory T cells (anti-CD25 or to block T cell suppression mediated through CTLA-4. As a result, the tumour burden was reduced by around 50% and the median survival time of mice to the humane endpoint was almost doubled the compared to controls. The incorporation of PADRE into the RHDV-VLP was necessary for an E6-specific enhancement of the anti-tumour response and the co-administration of the immune modifying antibodies contributed to the overall efficacy of the immunotherapy. The E6-RHDV-VLP-PADRE shows immunotherapeutic efficacy, prolonging survival for HPV tumour-bearing mice. This was enhanced by the systemic administration of immune-modifying antibodies that are commercially available for use in humans. There is potential to further modify these particles for even greater efficacy in the path to development of an immunotherapeutic treatment for HPV precancerous and cancer stages.

  13. A database survey of equine tumours in the United Kingdom.

    Science.gov (United States)

    Knowles, E J; Tremaine, W H; Pearson, G R; Mair, T S

    2016-05-01

    Survey data on equine tumours are sparse compared with other species and may have changed over time. To describe the most frequently diagnosed equine tumours recorded by a diagnostic pathology laboratory over 29 years, to identify background factors associated with tumour type, and to identify any changes in the tumours diagnosed or the background of cases submitted during the study period. Observational; cross-sectional analysis of records of a diagnostic pathology laboratory. The records of all neoplastic equine histology submissions to the University of Bristol (January 1982-December 2010) were accessed from a database, and a list of diagnoses compiled. The 6 most commonly diagnosed tumour types were analysed using logistic regression to identify background factors associated with tumour type. The overall population of equine tumour submissions and the relative frequency of diagnosis of the most common tumour types were compared between decades. There were 964 cases included. The most frequently diagnosed tumours were: sarcoid (24% cases), squamous cell carcinoma (SCC) (19%), lymphoma (14%), melanoma (6%), gonadal stromal tumour (6%) and mast cell tumour (MCT) (4%). With sarcoid, Thoroughbred/Thoroughbred cross and gelding as reference categories: increasing age was significantly associated with the odds of each of the other tumour types, mares were at reduced risk of SCC, Arab/Arab cross had a higher risk of MCT, Cob/Cob cross had an increased risk of SCC and MCT, and ponies had an increased risk of melanoma. The mean age of submissions increased in each successive decade and the breed composition became broader. Sarcoids and lymphoma formed a smaller proportion of diagnoses in later decades. The types of tumours submitted to this laboratory have changed over the last 3 decades. Current data inform clinicians and researchers and further studies are warranted to follow trends. © 2015 EVJ Ltd.

  14. An experimental study of tumour size and radiosensitivity

    International Nuclear Information System (INIS)

    Hill, S.A.; Denekamp, J.

    1989-01-01

    When designing experimental studies of tumours, it is considered important to control all variables that might alter the radiosensitivity and hence influence the variability of the data. One such variable is tumour size. We have studied the regrowth delay of a mammary carcinoma treated at 2-10 mm mean diameter (a 125-fold change of volume) with X-rays alone or X-rays plus misonidazole (MISO). The data were analysed to give dose-response curves, using four endpoints. Regrowth to a fixed size (4.5 mm larger than treatment size), or by a fixed increment (4 times the original volume) was expressed either as absolute delay, or as specific growth delay to allow for the changes in volume doubling time as the tumour grows. The method of analysis made no difference to the measured sensitizer enhancement ratio (SER) for MISO. The SER was dose-dependent, being higher doses, but was not different in tumours of 2 or 10 mm diameter. However, when comparing response to X-rays alone, the method of analysis made a very big difference to the conclusions. Regrowth to R + 4.5 mm showed no change in radiosensitivity with tumour size, but regrowth to 4 times the original volume (the most logical endpoint) indicated that large tumours were more sensitive than small. We conclude that regrowth delay may be an inappropriate method for comparing absolute sensitivities of tumours of different sizes. However, for studying the effectiveness of a radiomodifier the constraints of tumour size at irradiation seem to be less severe than previously believed. (author). 8 refs.; 8 figs

  15. STUDY OF PAEDIATRIC SOLID TUMOURS FOR A PERIOD OF 5 YEARS

    Directory of Open Access Journals (Sweden)

    Basumitra Das

    2017-12-01

    Full Text Available BACKGROUND Paediatric Solid Neoplasms (PSN are a global problem. There is significant variation of incidence of paediatric solid neoplasms in various regions of the world. Benign tumours are more common than cancer. In an effort to better understand the prevalence of paediatric solid tumours in our region, a retrospective review of the tumours diagnosed histopathologically was carried out. MATERIALS AND METHODS This is a retrospective study undertaken in a tertiary care hospital for a period of five years. All the benign and malignant paediatric solid tumours of children below 14 years from January 2012 to December 2016 were retrieved and analysed according to age, sex and histopathological diagnosis. Leukaemias were excluded from our study. All tumours were diagnosed on conventional haematoxylin and eosin-stained sections. RESULTS A total of 109 cases of solid paediatric tumours were received during this period. Of these, maximum of 30 tumours were of soft tissue tumours followed by Central Nervous System (CNS and bone tumours with 24 and 23 cases, respectively. 7 cases of blastomas were also observed. CONCLUSION This study showed benign and malignant tumours to be of near-equal prevalence. Soft tissue tumours were the most common. Ratio of benign tumours to malignant were almost equal below 4 years. Malignant tumours were higher in 5-9 years group.

  16. Childhood vascular Tumours in Benin City, Nigeria | Igbe | Annals of ...

    African Journals Online (AJOL)

    Background: Vasoformative tumours are one of the commonest tumours in childhood. The patterns of these tumours in Benin City, however, are not known. Objective: To determine the incidence and morphological patterns of childhood vascular tumours as seen in the Department of Pathology University of Benin Teaching ...

  17. Sensitivity and specificity of thallium-201 single-photon emission tomography in the functional detection and differential diagnosis of brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, R.A. (Dept. of Nuclear Medicine, Middelheim Hospital, Antwerp (Belgium)); Martin, J.J. (Dept. of Neurology, University Hospital, Antwerp (Belgium) Lab. of Neuropathology, Born-Bunge Foundation, Univ. of Antwerp (Belgium)); Dobbeleir, A. (Dept. of Nuclear Medicine, Middelheim Hospital, Antwerp (Belgium)); Crols, R. (Dept. of Neurology, Middelheim Hospital, Antwerp (Belgium)); Neetens, I. (Dept. of Pathology, Middelheim Hospital, Antwerp (Belgium)); Deyn, P.P. de (Lab. of Neuropathology, Born-Bunge Foundation, Univ. of Antwerp (Belgium) Lab. of Neurochemistry and Behaviour, Born-Bunge Foundation, Univ. of Antwerp (Belgium))

    1994-07-01

    Histologically tumours consisted of astrocytoma stage I or II, astrocytoma stage III, glioblastoma multiforme and oligodendroglioma, brain metastasis, lymphoma, meningioma, pituitary adenoma, pineal tumour, colloid cyst and craniopharyngioma. False-negative studies included pineal tumour, colloid cyst, craniopharyngioma, astrocytomas stage I or II and stage III, oligodendroglioma and metastasis in the brain stem. Additional metastases approximately < 1.5 cm were not detected in two patients and [sup 201]Tl SPET underestimated tumoral extent in one patient suffering from glioblastoma multiforme. A false-positive study was obtained in a patient with skull metastasis. All 15 patients who were finally shown to suffer from ischaemic infarction had a normal SPET study 9-28 days after the onset of symptomatology. Of five patients with haemorrhagic infarction, studied within 2 weeks, four were false-positive. Of six patients with intracranial haemorrhage, studied 9-39 days later, one showed focal [sup 201]Tl accumulation. Two further false-positive studies consisted of angioma and epidural haematoma. Finally, SPET studies were normal in six patients with definite diagnosis of (reactive) gliosis, Binswanger's encephalopathy, postinfectious encephalopathy and multiple sclerosis. In the patient population presented, sensitivity of [sup 201]Tl SPET for supratentorial brain tumours was 71.7% and specificity was 80.9%. Clinical information and control SPET studies in combination with early, 30-min and 3- to 4-h delayed imaging may be expected to improve on these figures. On the other hand it seems that, in addition to tumoral histology, the presence of tumours in the fossa posterior and small volumes contribute to the occurrence of false-negative [sup 201]Tl SPET studies. (orig.)

  18. Haemorrhagic pituitary tumours

    International Nuclear Information System (INIS)

    Lazaro, C.M.; Philippine General Hospital, Manila; Guo, W.Y.; Sami, M.; Hindmarsch, T.; Ericson, K.; Hulting, A.L.; Wersaell, J.

    1994-01-01

    In a group of 69 patients with pituitary tumours, 12 were found to have evidence of intratumoral haemorrhage on MRI, characterized by high signal intensity on short TR/TE sequences. This was verified in all but 1 patient. The majority of the bleedings occurred in macroadenomas. Five (42%) were prolactinomas and 4 (33%) were non-functioning adenomas. There were 2 GH- and 1 ACTH-secreting tumours. All 5 patients with prolactinomas were on bromocriptine medication. Two of the patients had a clinical picture of pituitary apoplexy. The haemorrhage was not large enough to prompt surgery in any of the patients. However, surgical verification of the diagnosis was obtained in 5 cases, while 6 patients were examined with follow-up MRI. (orig.)

  19. Gelatinase B/MMP-9 in Tumour Pathogenesis and Progression

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Antonietta Rosella; Mackay, Andrew Reay, E-mail: andrewreay.mackay@univaq.it [Department of Applied Clinical and Biotechnological Sciences, University of L’Aquila, Via Vetoio, Coppito 2, L’Aquila 67100 (Italy)

    2014-01-27

    Since its original identification as a leukocyte gelatinase/type V collagenase and tumour type IV collagenase, gelatinase B/matrix metalloproteinase (MMP)-9 is now recognised as playing a central role in many aspects of tumour progression. In this review, we relate current concepts concerning the many ways in which gelatinase B/MMP-9 influences tumour biology. Following a brief outline of the gelatinase B/MMP-9 gene and protein, we analyse the role(s) of gelatinase B/MMP-9 in different phases of the tumorigenic process, and compare the importance of gelatinase B/MMP-9 source in the carcinogenic process. What becomes apparent is the importance of inflammatory cell-derived gelatinase B/MMP-9 in tumour promotion, early progression and triggering of the “angiogenic switch”, the integral relationship between inflammatory, stromal and tumour components with respect to gelatinase B/MMP-9 production and activation, and the fundamental role for gelatinase B/MMP-9 in the formation and maintenance of tumour stem cell and metastatic niches. It is also apparent that gelatinase B/MMP-9 plays important tumour suppressing functions, producing endogenous angiogenesis inhibitors, promoting inflammatory anti-tumour activity, and inducing apoptosis. The fundamental roles of gelatinase B/MMP-9 in cancer biology underpins the need for specific therapeutic inhibitors of gelatinase B/MMP-9 function, the use of which must take into account and substitute for tumour-suppressing gelatinase B/MMP-9 activity and also limit inhibition of physiological gelatinase B/MMP-9 function.

  20. Anthropogenic selection enhances cancer evolution in Tasmanian devil tumours.

    Science.gov (United States)

    Ujvari, Beata; Pearse, Anne-Maree; Swift, Kate; Hodson, Pamela; Hua, Bobby; Pyecroft, Stephen; Taylor, Robyn; Hamede, Rodrigo; Jones, Menna; Belov, Katherine; Madsen, Thomas

    2014-02-01

    The Tasmanian Devil Facial Tumour Disease (DFTD) provides a unique opportunity to elucidate the long-term effects of natural and anthropogenic selection on cancer evolution. Since first observed in 1996, this transmissible cancer has caused local population declines by >90%. So far, four chromosomal DFTD variants (strains) have been described and karyotypic analyses of 253 tumours showed higher levels of tetraploidy in the oldest strain. We propose that increased ploidy in the oldest strain may have evolved in response to effects of genomic decay observed in asexually reproducing organisms. In this study, we focus on the evolutionary response of DFTD to a disease suppression trial. Tumours collected from devils subjected to the removal programme showed accelerated temporal evolution of tetraploidy compared with tumours from other populations where no increase in tetraploid tumours were observed. As ploidy significantly reduces tumour growth rate, we suggest that the disease suppression trial resulted in selection favouring slower growing tumours mediated by an increased level of tetraploidy. Our study reveals that DFTD has the capacity to rapidly respond to novel selective regimes and that disease eradication may result in novel tumour adaptations, which may further imperil the long-term survival of the world's largest carnivorous marsupial.