WorldWideScience

Sample records for intrachromosomal insertion determined

  1. Male and female meiotic behaviour of an intrachromosomal insertion determined by preimplantation genetic diagnosis

    Directory of Open Access Journals (Sweden)

    Doshi Alpesh

    2010-02-01

    Full Text Available Abstract Background Two related family members, a female and a male balanced carrier of an intrachromosomal insertion on chromosome 7 were referred to our centre for preimplantation genetic diagnosis. This presented a rare opportunity to investigate the behaviour of the insertion chromosome during meiosis in two related carriers. The aim of this study was to carry out a detailed genetic analysis of the preimplantation embryos that were generated from the three treatment cycles for the male and two for the female carrier. Patients underwent in vitro fertilization and on day 3, 22 embryos from the female carrier and 19 embryos from the male carrier were biopsied and cells analysed by fluorescent in situ hybridization. Follow up analysis of 29 untransferred embryos was also performed for confirmation of the diagnosis and to obtain information on meiotic and mitotic outcome. Results In this study, the female carrier produced more than twice as many chromosomally balanced embryos as the male (76.5% vs. 36%, and two pregnancies were achieved for her. Follow up analysis showed that the male carrier had produced more highly abnormal embryos than the female (25% and 15% respectively and no pregnancies occurred for the male carrier and his partner. Conclusion This study compares how an intrachromosomal insertion has behaved in the meiotic and preimplantation stages of development in sibling male and female carriers. It confirms that PGD is an appropriate treatment in such cases. Reasons for the differing outcome for the two carriers are discussed.

  2. Human MLH1 suppresses the insertion of telomeric sequences at intra-chromosomal sites in telomerase-expressing cells

    Science.gov (United States)

    Jia, Pingping; Chastain, Megan; Zou, Ying; Her, Chengtao

    2017-01-01

    Abstract Aberrant formation of interstitial telomeric sequences (ITSs) promotes genome instabilities. However, it is unclear how aberrant ITS formation is suppressed in human cells. Here, we report that MLH1, a key protein involved in mismatch repair (MMR), suppresses telomeric sequence insertion (TSI) at intra-chromosomal regions. The frequency of TSI can be elevated by double-strand break (DSB) inducer and abolished by ATM/ATR inhibition. Suppression of TSI requires MLH1 recruitment to DSBs, indicating that MLH1's role in DSB response/repair is important for suppressing TSI. Moreover, TSI requires telomerase activity but is independent of the functional status of p53 and Rb. Lastly, we show that TSI is associated with chromosome instabilities including chromosome loss, micronuclei formation and chromosome breakage that are further elevated by replication stress. Our studies uncover a novel link between MLH1, telomerase, telomere and genome stability. PMID:28180301

  3. Chromatin Structure and Radiation-Induced Intrachromosome Exchange

    Science.gov (United States)

    Mangala; Zhang, Ye; Hada, Megumi; Cucinotta, Francis A.; Wu, Honglu

    2011-01-01

    We have recently investigated the location of breaks involved in intrachromosomal type exchange events, using the multicolor banding in situ hybridization (mBAND) technique for human chromosome 3. In human epithelial cells exposed to both low- and high-LET radiations in vitro, intrachromosome exchanges were found to occur preferentially between a break in the 3p21 and one in the 3q11. Exchanges were also observed between a break in 3p21 and one in 3q26, but few exchanges were observed between breaks in 3q11 and 3q26, even though the two regions were on the same arm of the chromosome. To explore the relationships between intrachromosome exchanges and chromatin structure, we used probes that hybridize the three regions of 3p21, 3q11 and 3q26, and measured the distance between two of the three regions in interphase cells. We further analyzed fragile sites on the chromosome that have been identified in various types of cancers. Our results demonstrated that the distribution of breaks involved in radiation-induced intrachromosome aberrations depends upon both the location of fragile sites and the folding of chromatins

  4. Intra-chromosomal aberrations observed after high-LET radiation exposure in vivo using a state-of-the-art cytogenetic technique

    International Nuclear Information System (INIS)

    Mitchell, C.R.; Geard, C.R.; Brenner, D.J.; Hande, P.; Azizova, T.V.; Burak, L.E.; Khokhryakov, V.F.; Vasienko, E.K.

    2003-01-01

    Multicolor banding fluorescence in situ hybridization (mBAND) was used to investigate the presence of stable intra-chromosomal aberrations in chromosomes 1, 2 and 5 in a population of individuals exposed previously to low and/or high-LET radiation. Peripheral blood lymphocytes were taken from healthy Russian nuclear workers occupationally exposed to plutonium α -particles, γ -rays or both at the Mayak complex from 1949 onwards. Metaphase spreads were produced and chromosomes hybridized with mBAND probes and scored for intra-chromosomal aberrations including inversions and deletions. A large difference between the intra-chromosomal aberration frequencies for the high-plutonium (∼1.1 Gy) and the high- γ exposed (∼1.5 Gy) individuals was observed in all three chromosomes studied (chromosome 1: 1.9 ± 0.5 % (n=7) vs. 0.1 ± 0.1% (n=5); chromosome 2: 1.7 ± 0.4% (n=7) vs. 0 [0 -0.3]% (n=6); chromosome 5: 3.7 ± 0.5 % (n=11) vs. 0.1 ± 0.1 % (n=11) (high-plutonium vs. high-γ exposure)). Controls (n=5) showed very few or no intra-chromosomal aberrations. Significantly fewer aberrations were observed in chromosomes 1 and 2 compared with chromosome 5, studied previously in this cohort, suggesting that intra-chromosomal changes involving chromosomes 1 and 2 may be more lethal to the cell than those involving chromosome 5. The dramatic differences in yields of intra-chromosomal aberrations in high-plutonium exposure relative to low may provide a means of discrimination to estimate both the dose and type of previous radiation exposure in populations

  5. Frequency of intrachromosomal homologous recombination induced by UV radiation in normally repairing and excision repair-deficient human cells

    International Nuclear Information System (INIS)

    Tsujimura, T.; Maher, V.M.; McCormick, J.J.; Godwin, A.R.; Liskay, R.M.

    1990-01-01

    To investigate the role of DNA damage and nucleotide excision repair in intrachromosomal homologous recombination, a plasmid containing duplicated copies of the gene coding for hygromycin resistance was introduced into the genome of a repair-proficient human cell line, KMST-6, and two repair-deficient lines, XP2OS(SV) from xeroderma pigmentosum complementation group A and XP2YO(SV) from complementation group F. Neither hygromycin-resistance gene codes for a functional enzyme because each contains an insertion/deletion mutation at a unique site, but recombination between the two defective genes can yield hygromycin-resistant cells. The rates of spontaneous recombination in normal and xeroderma pigmentosum cell strains containing the recombination substrate were found to be similar. The frequency of UV-induced recombination was determined for three of these cell strains. At low doses, the group A cell strain and the group F cell strain showed a significant increase in frequency of recombinants. The repair-proficient cell strain required 10-to 20-fold higher doses of UV to exhibit comparable increases in frequency of recombinants. These results suggest that unexcised DNA damage, rather than the excision repair process per se, stimulates such recombination

  6. Intrachromosomal amplification, locus deletion and point mutation in the aquaglyceroporin AQP1 gene in antimony resistant Leishmania (Viannia guyanensis.

    Directory of Open Access Journals (Sweden)

    Rubens Monte-Neto

    2015-02-01

    Full Text Available Antimony resistance complicates the treatment of infections caused by the parasite Leishmania.Using next generation sequencing, we sequenced the genome of four independent Leishmania guyanensis antimony-resistant (SbR mutants and found different chromosomal alterations including aneuploidy, intrachromosomal gene amplification and gene deletion. A segment covering 30 genes on chromosome 19 was amplified intrachromosomally in three of the four mutants. The gene coding for the multidrug resistance associated protein A involved in antimony resistance was also amplified in the four mutants, most likely through chromosomal translocation. All mutants also displayed a reduced accumulation of antimony mainly due to genomic alterations at the level of the subtelomeric region of chromosome 31 harboring the gene coding for the aquaglyceroporin 1 (LgAQP1. Resistance involved the loss of LgAQP1 through subtelomeric deletions in three mutants. Interestingly, the fourth mutant harbored a single G133D point mutation in LgAQP1 whose role in resistance was functionality confirmed through drug sensitivity and antimony accumulation assays. In contrast to the Leishmania subspecies that resort to extrachromosomal amplification, the Viannia strains studied here used intrachromosomal amplification and locus deletion.This is the first report of a naturally occurred point mutation in AQP1 in antimony resistant parasites.

  7. Distributions of Low- and High-LET Radiation-Induced Breaks in Chromosomes are Associated with Inter- and Intrachromosome Exchanges

    Science.gov (United States)

    Hada, Megumi; Zhang, Ye; Feiveson, Alan; Cucinotta, Francis A.; Wu, Honglu

    2010-01-01

    To study the breakpoint along the length of the chromosome induced by low- and high-LET radiations, we exposed human epithelial cells in vitro to Cs-137 rays at both low and high dose rates, secondary neutrons at a low dose rate, and 600 MeV/u Fe ions at a high dose rate. The location of the breaks was identified using the multicolor banding in situ hybridization (mBAND) that paints Chromosome 3 in 23 different colored bands. The breakpoint distributions were found to be similar between rays of low and high dose rates and between the two high-LET radiation types. Detailed analysis of the chromosome break ends involved in inter- and intrachromosome exchanges revealed that only the break ends participating in interchromosome exchanges contributed to the hot spots found for low-LET. For break ends participating in intrachromosome exchanges, the distributions for all four radiation scenarios were similar with clusters of breaks found in three regions. Analysis of the locations of the two break ends in Chromosome 3 that joined to form an intrachromosome exchange demonstrated that two breaks with a greater genomic separation may be more likely to rejoin than two closer breaks, indicating that chromatin folding can play an important role in the rejoining of chromosome breaks. Our study demonstrated that the gene-rich regions do not necessarily contain more breaks. The breakpoint distribution depends more on the likelihood that a break will join with another break in the same chromosome or in a different chromosome.

  8. Induction of intrachromosomal homologous recombination in whole plants

    International Nuclear Information System (INIS)

    Puchta, H.; Swoboda, P.; Hohn, B.

    1995-01-01

    The influence of different factors on frequencies of intrachromosomal homologous recombination in whole Arabidopsis thaliana and tobacco plants was analyzed using a disrupted β-glucuronidase marker gene. Recombination frequencies were enhanced several fold by DNA damaging agents like UV-light or MMS (methyl methanesulfonate). Applying 3-methoxybenzamide (3-MB), an inhibitor of poly(ADP)ribose polymerase (PARP), an enzyme that is postulated to be involved in DNA repair, enhanced homologous recombination frequencies strongly. These findings indicate that homologous recombination is involved in DNA repair and can (at least partially) compensate for other DNA repair pathways. Indications that recombination in plants can be induced by environmental stress factors that are not likely to be involved in DNA metabolism were also found; Arabidopsis plants growing in a medium containing 0.1 M NaCl exhibited elevated recombination frequencies. The possible general effects of ‘environmental’ challenges on genome flexibility are discussed. (author)

  9. The Correlation of Interphase Chromatin Structure with the Radiation-Induced Inter- and Intrachromosome Exchange Hotspots

    Science.gov (United States)

    Zhang, Ye; Mangala, Lingegowda S.; Purgason, Ashley M.; Hada, Megumi; Cucinotta, Francis A.; Wu, Honglu

    2011-01-01

    To investigate the relationship between chromosome aberrations induced by radiation and chromatin folding, we reconstructed three dimensional structure of chromosome 3 and measured the physical distances between different regions of the chromosome. Previously, we have investigated the location of breaks involved in inter- and intrachromosomal type exchange events in human chromosome 3, using the multicolor banding in situ hybridization (mBAND) technique. In human epithelial cells exposed to both low- and high-LET radiations in vitro, we reported that intra-chromosome exchanges occurred preferentially between a break in the 3p21 and one in the 3q11 regions, and the breaks involving in inter-chromosome exchanges occurred in two regions towards the telomeres of the chromosome. Exchanges were also observed between a break in 3p21 and one in 3q26, but few exchanges were observed between breaks in 3q11 and 3q26, even though the two regions are located on the same arm of the chromosome. In this study, human epithelial cells were fixed at G1 phase and the interphase cells were hybridized using the XCyte3 mBAND kit from MetaSystems. The z-section images of chromosome 3 were captured with a Leica and an LSM 510 Meta laser scanning confocal microscopes. A total of 100 chromosomes were analyzed. The reconstruction of three dimensional structure of interphase chromosome 3 with six different colored regions was achieved using the Imaris software. The relative distance between different regions was measured as well. We further analyzed fragile sites on the chromosome that have been identified in various types of cancers. The data showed that, in majority of the cells, the regions containing 3p21 and 3q11 are colocalized in the center of the chromosome, whereas, the regions towards the telomeres of the chromosome are either physically wrapping outside the chromosome center or with arms sticking out. Our results demonstrated that the distribution of breaks involved in radiation

  10. Mini-Mu insertions in the tetracycline resistance determinant from Proteus mirabilis

    Directory of Open Access Journals (Sweden)

    Magalhães V.D.

    1997-01-01

    Full Text Available The inducible tetracycline resistance determinant isolated from Proteus mirabilis cloned into the plasmid pACYC177 was mutagenized by insertion of a mini-Mu-lac phage in order to define the regions in the cloned sequences encoding the structural and regulatory proteins. Three different types of mutants were obtained: one lost the resistance phenotype and became Lac+; another expressed the resistance at lower levels and constitutively; the third was still dependent on induction but showed a lower minimal inhibitory concentration. The mutant phenotypes and the locations of the insertions indicate that the determinant is composed of a repressor gene and a structural gene which are not transcribed divergently as are other known tetracycline determinants isolated from Gram-negative bacteria

  11. Effects of DNA double-strand and single-strand breaks on intrachromosomal recombination events in cell-cycle-arrested yeast cells

    International Nuclear Information System (INIS)

    Galli, A.; Schiestl, R.H.

    1998-01-01

    Intrachromosomal recombination between repeated elements can result in deletion (DEL recombination) events. We investigated the inducibility of such intrachromosomal recombination events at different stages of the cell cycle and the nature of the primary DNA lesions capable of initiating these events. Two genetic systems were constructed in Saccharomyces cerevisiae that select for DEL recombination events between duplicated alleles of CDC28 and TUB2. We determined effects of double-strand breaks (DSBs) and single-strand breaks (SSBs) between the duplicated alleles on DEL recombination when induced in dividing cells or cells arrested in G1 or G2. Site-specific DSBs and SSBs were produced by overexpression of the I-Sce I endonuclease and the gene II protein (gIIp), respectively. I-Sce I-induced DSBs caused an increase in DEL recombination frequencies in both dividing and cell-cycle-arrested cells, indicating that G1- and G2-arrested cells are capable of completing DSB repair. In contrast, gIIp-induced SSBs caused an increase in DEL recombination frequency only in dividing cells. To further examine these phenomena we used both γ-irradiation, inducing DSBs as its most relevant lesion, and UV, inducing other forms of DNA damage. UV irradiation did not increase DEL recombination frequencies in G1 or G2, whereas γ-rays increased DEL recombination frequencies in both phases. Both forms of radiation, however, induced DEL recombination in dividing cells. The results suggest that DSBsbut not SSBs induce DEL recombination, probably via the single-strand annealing pathway. Further, DSBs in dividing cells may result from the replication of a UV or SSB-damaged template. Alternatively, UV induced events may occur by replication slippage after DNA polymerase pausing in front of the damage. (author)

  12. Intrachromosomal exchange aberrations predicted on the basis of globular interphase chromosome model

    International Nuclear Information System (INIS)

    Andreev, S.G.; Eidelman, Yu.A.

    2002-01-01

    One of the key questions in understanding mechanisms of chromosome aberration production is how does interphase chromosome structure affect aberration formation. To explore this a modelling approach is presented which combines Monte Carlo simulation of both a particle track and interphase chromosome structure. The structural state of interphase chromosome influences a dose-effect relationship for intrachromosomal exchange aberrations (intrachanges). It is shown that intrachanges are induced frequently by both X rays and a particles if the chromosome is in the condensed globular but not in the decondensed coiled state. Truly simple intra-arm intrachanges induced by X rays are dose squared in coiled chromosomes, but exhibit linear dose dependence in globular chromosomes. Experimental data on interarm intrachanges obtained by dual arm chromosome painting are analysed by means of the technique presented. Results of analysis support the conclusion about the arms proximity of chromosome 1 in human lymphocytes. (author)

  13. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  14. Mutational scanning reveals the determinants of protein insertion and association energetics in the plasma membrane.

    Science.gov (United States)

    Elazar, Assaf; Weinstein, Jonathan; Biran, Ido; Fridman, Yearit; Bibi, Eitan; Fleishman, Sarel Jacob

    2016-01-29

    Insertion of helix-forming segments into the membrane and their association determines the structure, function, and expression levels of all plasma membrane proteins. However, systematic and reliable quantification of membrane-protein energetics has been challenging. We developed a deep mutational scanning method to monitor the effects of hundreds of point mutations on helix insertion and self-association within the bacterial inner membrane. The assay quantifies insertion energetics for all natural amino acids at 27 positions across the membrane, revealing that the hydrophobicity of biological membranes is significantly higher than appreciated. We further quantitate the contributions to membrane-protein insertion from positively charged residues at the cytoplasm-membrane interface and reveal large and unanticipated differences among these residues. Finally, we derive comprehensive mutational landscapes in the membrane domains of Glycophorin A and the ErbB2 oncogene, and find that insertion and self-association are strongly coupled in receptor homodimers.

  15. Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy

    International Nuclear Information System (INIS)

    Verma, S.P.; Sonwalkar, N.

    1993-01-01

    The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22 o C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm -1 (amide I), 1200-1300 cm -1 (amide III) and 550-1030 cm -1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm -1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and III bands. Quantitative estimation using the curve fitting method shows that ban 3 contains 44% total helix, 48% beta strand and 8% undefined plus turns (error + or - 4%). The secondary structure changes to 35% total helix, 42% total beta-strand and 23% turned and undefined upon irradiating band 3 containing liposomes. (Author)

  16. Determination of rod insertion limits of the AP600'S M-shim bank at low power operating mode

    International Nuclear Information System (INIS)

    Sutondo, Tegas

    2002-01-01

    A series of calculation works had been conducted to determine the AP00's M-shim bank insertion limits during low-power operating mode. This activity was a part of the preliminary studies toward the plan on implementation a Rapid Power Reduction System (RPRS) in AP00's control / operating system, that enable it to operate under low power level (below 50% RTP). The calculations were performed for cycle 1 and equilibrium cycle as function of power levels and the fraction of AO-bank insertion. The results show that the M-shim insertion limits for both cycle 1 and equilibrium cycle were determined based on the limiting conditions at low-burn-up level (BOL), and high burn-up level (EOL) respectively

  17. Effect of low dose radiation on somatic intrachromosomal recombination in vivo and in vitro

    International Nuclear Information System (INIS)

    Hooker, A.M.; Cormack, J.; Morley, A.A.; Sykes, P.J.; Bhat, M.

    2003-01-01

    Full text: High doses of ionising radiation are mutagenic in a wide range of mutation assays. The majority of radiation exposure studies in in vivo mouse mutation assays have been performed at high doses, eg greater than 1 Gy. However, these doses are not relevant to the low doses of ionising radiation that the majority of the population might likely come into contact with. Radiation protection levels tend to be based on a simple linear no-threshold model which suggests that any radiation above zero is potentially harmful. The pKZ1 recombination mutagenesis mouse model has proven to be a sensitive assay for the detection of mutations caused by low doses of chemical agents. In pKZ1 mice, somatic intrachromosomal recombination (SICR) inversion events can be detected in cells using histochemistry for the E. coli LacZ transgene. We exposed pKZ1 mice to a single radiation dose ranging from 0.001 to 2 Gy. A significant increase in SICR was observed in spleen at the two highest doses of 0.1 and 2 Gy and a significant reduction in SICR below the endogenous frequency was observed at the two lowest doses of 0.01 and 0.001 Gy. After exposing a pKZ1 cell line to the same dose range, a similar J curve response was observed with significant increases in SICR observed at the 3 highest doses and a significant decrease below the endogenous frequency at the lowest dose (0.001 Gy). The next experiments will be to determine the dose where the SICR frequency returns to the endogenous level. The important question posed by these results is 'Is a reduction below the endogenous SICR level caused by low doses of ionising radiation anti-mutagenic?' Studies now need to be performed to investigate the effect of low doses of radiation on other mutation end-points, and the mechanism for the reduction in SICR

  18. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  19. Randomised Controlled Trial to determine the appropriate time to initiate peritoneal dialysis after insertion of catheter to minimise complications (Timely PD study

    Directory of Open Access Journals (Sweden)

    Fassett Robert G

    2010-06-01

    Full Text Available Abstract Background The most appropriate time to initiate dialysis after surgical insertion of Tenckhoff catheters is not clear in the literature. There is the possibility of peritoneal dialysis (PD complications such as leakage and infection if dialysis is started too soon after insertion. However, much morbidity and expense could be saved by reducing dependency on haemodialysis (HD by earlier initiation of PD post catheter insertion. Previous studies are observational and mostly compare immediate with delayed use. The primary objective is to determine the safest and shortest time interval between surgical placement of a Tenckhoff catheter and starting PD. Methods/Design This is a randomised controlled trial of patients who will start PD after insertion of Tenckhoff catheter at Royal Brisbane and Women's Hospital (RBWH or Rockhampton Base Hospital (RBH who meet the inclusion criteria. Patients will be stratified by site and diabetic status. The patients will be randomised to one of three treatment groups. Group 1 will start PD one week after Tenckhoff catheter insertion, group 2 at two weeks and group 3 at four weeks. Nurses and physicians will be blinded to the randomised allocation. The primary end point is the complication rate (leaks and infection after initiation of PD. Discussion The study will determine the most appropriate time to initiate PD after placement of a Tenckhoff catheter. Trial Registration ACTRN12610000076077

  20. Agitation within Mk-42 insert caused by air sparge

    International Nuclear Information System (INIS)

    Ramsey, C.J.

    1991-01-01

    Dissolution of Rocky Flats Pu alloys and Pu metal using a ''nested insert'' configuration (One Well Insert (S-3352) inside the Mk-42 Insert) will require a Nuclear Safety Study, a major assumption of which will be that the annular dissolver is well-mixed. The ''well-mixed'' assumption was theoretically and experimentally supported for alloy dissolution using the Three Well Insert, but the present situation differs significantly. In the former case, the insert was directly exposed to the agitation induced by air sparging; in the case under consideration, the One Well Insert would be shielded by the Mk-42 Insert. In an effort to determine if the ''nested insert'' approach should be pursued, the past studies and technical literature have been surveyed and an attempt made to predict the extent of mixing and bulk circulation for a ''nested insert'' configuration in the presence of air sparging

  1. Z-2 Threaded Insert Design and Testing

    Science.gov (United States)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  2. An international study of intrachromosomal amplification of chromosome 21 (iAMP21): cytogenetic characterization and outcome

    Science.gov (United States)

    Harrison, CJ; Moorman, AV; Schwab, C; Carroll, AJ; Raetz, EA; Devidas, M; Strehl, S; Nebral, K; Harbott, J; Teigler-Schlegel, A; Zimmerman, M; Dastuge, N; Baruchel, A; Soulier, J; Auclerc, M-F; Attarbaschi, A; Mann, G; Stark, B; Cazzaniga, G; Chilton, L; Vandenberghe, P; Forestier, E; Haltrich, I; Raimondi, SC; Parihar, M; Bourquin, J-P; Tchinda, J; Haferlach, C; Vora, A; Hunger, SP; Heerema, NA; Haas, OA

    2014-01-01

    Intrachromosomal amplification of chromosome 21 (iAMP21) defines a distinct cytogenetic subgroup of childhood B-cell precursor acute lymphoblastic leukaemia (BCP-ALL). To date, fluorescence in situ hybridisation (FISH), with probes specific for the RUNX1 gene, provides the only reliable detection method (five or more RUNX1 signals per cell). Patients with iAMP21 are older (median age 9 years) with a low white cell count. Previously, we demonstrated a high relapse risk when these patients were treated as standard risk. Recent studies have shown improved outcome on intensive therapy. In view of these treatment implications, accurate identification is essential. Here we have studied the cytogenetics and outcome of 530 iAMP21 patients that highlighted the association of specific secondary chromosomal and genetic changes with iAMP21 to assist in diagnosis, including the gain of chromosome X, loss or deletion of chromosome 7, ETV6 and RB1 deletions. These iAMP21 patients when treated as high risk showed the same improved outcome as those in trial-based studies regardless of the backbone chemotherapy regimen given. This study reinforces the importance of intensified treatment to reduce the risk of relapse in iAMP21 patients. This now well-defined patient subgroup should be recognised by World Health Organisation (WHO) as a distinct entity of BCP-ALL. PMID:24166298

  3. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  4. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  5. Neutron absorber inserts for 55-gal drums

    International Nuclear Information System (INIS)

    Wilson, R.E.; Kim, Y.S.; Toffer, H.

    2000-01-01

    Transport and temporary storage of more than 200 g of fissile material in 55-gal drums at the Rocky Flats Environmental Technology Site (RFETS) have received significant attention during the cleanup mission. This paper discusses successful applications and results of extensive computer studies. Interim storage and movement of fissile material in excess of standard drum limits (200 g) in a safe configuration have been accomplished using special drum inserts. Such inserts have constrained the contents of a drum to two 4-ell bottles. The content of the bottles was limited to 600 g Pu or U in solution or a total of 1200 g for the entire drum. The inserts were a simple design constructed of stainless steel, forming a vertical cylindrical pipe into which two bottles, one on top of the other, could be centered in the drum. The remaining drum volume was configured to preclude any additional bottle placement external to the vertical cylinder. Such inserts in drums were successfully used in moving high-concentration solution from one building to another for chemical processing. Concern about the knowledge of fissile material concentration in bottles prompted another study for drum inserts. The past practice had been to load up to fourteen 4-ell bottles into 55-gal drums, provided the fissile material concentration was < 6 g fissile/ell, and the total drum contents of 200 g fissile was not exceeded. Only one determination of the solution concentration was needed. An extensive safety analysis concluded that a single measurement of bottle content could not ensure compliance with double-contingency-criterion requirements. A second determination of the bottle contents was required before bottles could be placed in a 55-gal drum. Al alternative to a dual-measurement protocol, which is for bolstering administrative control, was to develop an engineered safety feature that would eliminate expensive tests and administrative decisions. A drum insert design was evaluated that would

  6. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  7. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  8. Myeloid Malignancies with Chromosome 5q Deletions Acquire a Dependency on an Intrachromosomal NF-κB Gene Network

    Directory of Open Access Journals (Sweden)

    Jing Fang

    2014-09-01

    Full Text Available Chromosome 5q deletions (del[5q] are common in high-risk (HR myelodysplastic syndrome (MDS and acute myeloid leukemia (AML; however, the gene regulatory networks that sustain these aggressive diseases are unknown. Reduced miR-146a expression in del(5q HR MDS/AML and miR-146a−/− hematopoietic stem/progenitor cells (HSPCs results in TRAF6/NF-κB activation. Increased survival and proliferation of HSPCs from miR-146alow HR MDS/AML is sustained by a neighboring haploid gene, SQSTM1 (p62, expressed from the intact 5q allele. Overexpression of p62 from the intact allele occurs through NF-κB-dependent feedforward signaling mediated by miR-146a deficiency. p62 is necessary for TRAF6-mediated NF-κB signaling, as disrupting the p62-TRAF6 signaling complex results in cell-cycle arrest and apoptosis of MDS/AML cells. Thus, del(5q HR MDS/AML employs an intrachromosomal gene network involving loss of miR-146a and haploid overexpression of p62 via NF-κB to sustain TRAF6/NF-κB signaling for cell survival and proliferation. Interfering with the p62-TRAF6 signaling complex represents a therapeutic option in miR-146a-deficient and aggressive del(5q MDS/AML.

  9. Identifying transposon insertions and their effects from RNA-sequencing data.

    Science.gov (United States)

    de Ruiter, Julian R; Kas, Sjors M; Schut, Eva; Adams, David J; Koudijs, Marco J; Wessels, Lodewyk F A; Jonkers, Jos

    2017-07-07

    Insertional mutagenesis using engineered transposons is a potent forward genetic screening technique used to identify cancer genes in mouse model systems. In the analysis of these screens, transposon insertion sites are typically identified by targeted DNA-sequencing and subsequently assigned to predicted target genes using heuristics. As such, these approaches provide no direct evidence that insertions actually affect their predicted targets or how transcripts of these genes are affected. To address this, we developed IM-Fusion, an approach that identifies insertion sites from gene-transposon fusions in standard single- and paired-end RNA-sequencing data. We demonstrate IM-Fusion on two separate transposon screens of 123 mammary tumors and 20 B-cell acute lymphoblastic leukemias, respectively. We show that IM-Fusion accurately identifies transposon insertions and their true target genes. Furthermore, by combining the identified insertion sites with expression quantification, we show that we can determine the effect of a transposon insertion on its target gene(s) and prioritize insertions that have a significant effect on expression. We expect that IM-Fusion will significantly enhance the accuracy of cancer gene discovery in forward genetic screens and provide initial insight into the biological effects of insertions on candidate cancer genes. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  10. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  11. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  12. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  13. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  14. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  15. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  16. Research on the Influence of Orthopaedic Inserts on Pressure Distribution in the Foot

    Directory of Open Access Journals (Sweden)

    Ignas Rutulys

    2011-02-01

    Full Text Available The article examines the influence of individual orthopaedic inserts on pressure distribution in the foot. Feet deformations, types of orthopaedic inserts, materials and pressure in the foot testing methods are discussed. Experimental computer measurements of pressure in the foot before and after the use of inserts have been done. During research, the inserts made of different kinds of materials selected according to human weight, pathology, skin sensitivity and many other reasons has been used. It has been determinated that orthopaedic inserts have a more noticeable impact on children whose feet is adjusted easier if compared with those of adults.Article in Lithuanian

  17. The insertion/deletion polymorphism of angiotensin-converting ...

    African Journals Online (AJOL)

    The association between type 2 diabetes mellitus (T2DM) and essential hypertension (EH) is not well understood. Both conditions result from an interaction of multiple genetic (ethnic) and environmental (geographical) factors. One possible genetic determinant is the angiotensin-converting enzyme (ACE) insertion/deletion ...

  18. Vacuum guidelines for ISA insertions

    International Nuclear Information System (INIS)

    Edwards, D. Jr.

    1976-01-01

    Vacuum requirements place design restrictions on the ISA insertions. The vacuum tube diameter, given a distance L between pumps, is determined by the desorption of molecules from the wall under the impact of ions created by the beam, whereas the thickness of the tube must be sufficient to prevent collapse. In addition, the entire vacuum chamber must be able to be baked out at approximately 200 0 C

  19. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  20. Determination and elimination of the reasons for increased control rod insertion time of the Kozloduy NPP WWER-1000

    International Nuclear Information System (INIS)

    Nikolov, K.

    1996-01-01

    The emergency insertion speed of the control rod upon reactor shutdown is of crucial importance for reactor safety. The designed insertion time for WWER-1000 reactors should be in the limits 1,5 to 4 s. Having in mind some data about increased insertion times of WWER-1000 type reactors in Russia and Ukraine, a practice of measuring this parameters during each planned outage of the Kozloduy NPP Unit 6 is introduced. Some technical improvements of the fuel assembly are made in order to reach the nominal parameters of the unit

  1. Hydration number of alkali metal ions determined by insertion in a conducting polymer

    DEFF Research Database (Denmark)

    Skaarup, Steen

    2008-01-01

    of all other water molecules whose properties are still influenced significantly by the cation. Knowing the hydration number is important when considering, for instance, the transport of Na+ and K+ in biological cell membranes, since their different behavior may depend on the details of ion hydration....... The solvation of alkali metal ions has been discussed for many years without a clear consensus. This work presents a systematic study of the hydration numbers of the 5 alkali metal ions, using the electrochemical insertion of the ions in a conducting polymer (polypyrrole containing the large immobile anion DBS...... direct calculation of the number of M+ ions entering the film, and therefore the inserted M+ mass. The mass of the water molecules is calculated as a difference. The results yield the following primary hydration numbers: Li+: 5.5-5.6; Na+: 4.0-4.1; K+: 2.0-2.5; Rb+: 0.6-1.2; Cs+: ~0. The most important...

  2. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  3. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  4. Pain from copper intrauterine device insertion: randomized trial of prophylactic ibuprofen.

    Science.gov (United States)

    Hubacher, David; Reyes, Veronica; Lillo, Sonia; Zepeda, Ana; Chen, Pai-Lien; Croxatto, Horacio

    2006-11-01

    This study was undertaken to determine whether 400 mg of prophylactic ibuprofen can alleviate pain from insertion of an intrauterine device (IUD) and to measure level of pain with improved techniques. We conducted a randomized, double-blind, placebo-controlled trial of 2019 first-time IUD users: 1008 women received placebo and 1011 women received 400 mg of ibuprofen. Participants took the single tablet at least 45 minutes before IUD insertion. Immediately after insertion, participants recorded level of pain by using a 10-cm visual analog scale, with the value of 10 meaning "worst imaginable pain." Median level of pain was 1.0 for both ibuprofen and placebo participants; rank test statistics confirmed no difference. Some subgroups of women experienced higher pain (eg, nulliparous women), but ibuprofen still had no important impact on level of pain. Even among first-time users, pain from IUD insertion is generally low. Prophylactic ibuprofen as used in this protocol does not reduce IUD insertion pain.

  5. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  6. Characterization of novel non-clonal intrachromosomal rearrangements between the H4 and PTEN genes (H4/PTEN) in human thyroid cell lines and papillary thyroid cancer specimens

    International Nuclear Information System (INIS)

    Puxeddu, Efisio; Zhao Guisheng; Stringer, James R.; Medvedovic, Mario; Moretti, Sonia; Fagin, James A.

    2005-01-01

    The two main forms of RET rearrangement in papillary thyroid carcinomas (PTC) arise from intrachromosomal inversions fusing the tyrosine kinase domain of RET with either the H4 (RET/PTC1) or the ELE1/RFG genes (RET/PTC3). PTEN codes for a dual-specificity phosphatase and maps to chromosome 10q22-23. Germline mutations confer susceptibility to Cowden syndrome whereas somatic mutations or deletions are common in several sporadic human tumors. Decreased PTEN expression has been implicated in thyroid cancer development. We report the characterization of a new chromosome 10 rearrangement involving H4 and PTEN. The initial H4/PTEN rearrangement was discovered as a non-specific product of RT-PCR for RET/PTC1 in irradiated thyroid cell lines. Sequencing revealed a transcript consisting of exon 1 and 2 of H4 fused with exons 3-6 of PTEN. Nested RT-PCR with specific primers bracketing the breakpoints confirmed the H4/PTEN rearrangements in irradiated KAT-1 and KAT-50 cells. Additional H4/PTEN variants, generated by recombination of either exon 1 or exon 2 of H4 with exon 6 of PTEN, were found in non-irradiated KAK-1, KAT-50, ARO and NPA cells. Their origin through chromosomal recombination was confirmed by detection of the reciprocal PTEN/H4 product. H4/PTEN recombination was not a clonal event in any of the cell lines, as Southern blots with appropriate probes failed to demonstrate aberrant bands, and multicolor FISH of KAK1 cells with BAC probes for H4 and PTEN did not show a signal overlap in all cells. Based on PCR of serially diluted samples, the minimal frequency of spontaneous recombination between these loci was estimated to be approximately 1/10 6 cells. H4/PTEN products were found by nested RT-PCR in 4/14 normal thyroid tissues (28%) and 14/18 PTC (78%) (P < 0.01). H4/PTEN is another example of recombination involving the H4 locus, and points to the high susceptibility of thyroid cells to intrachromosomal gene rearrangements. As this also represents a plausible

  7. Characterization of novel non-clonal intrachromosomal rearrangements between the H4 and PTEN genes (H4/PTEN) in human thyroid cell lines and papillary thyroid cancer specimens

    Energy Technology Data Exchange (ETDEWEB)

    Puxeddu, Efisio [Division of Endocrinology and Metabolism, University of Cincinnati College of Medicine, PO Box 670547, Cincinnati, OH 45267-0547 (United States); Zhao Guisheng [Division of Endocrinology and Metabolism, University of Cincinnati College of Medicine, PO Box 670547, Cincinnati, OH 45267-0547 (United States); Stringer, James R. [Department of Molecular Genetics, University of Cincinnati College of Medicine, PO Box 670547, Cincinnati, OH 45267-0547 (United States); Medvedovic, Mario [Center for Biostatistic Service, University of Cincinnati College of Medicine, PO Box 670547, Cincinnati, OH 45267-0547 (United States); Moretti, Sonia [Dipartimento di Medicina Interna, Universita degli Studi di Perugia, Via E. dal Pozzo, Perugia 06126, (Italy); Fagin, James A. [Division of Endocrinology and Metabolism, University of Cincinnati College of Medicine, PO Box 670547, Cincinnati, OH 45267-0547 (United States)]. E-mail: james.fagin@uc.edu

    2005-02-15

    The two main forms of RET rearrangement in papillary thyroid carcinomas (PTC) arise from intrachromosomal inversions fusing the tyrosine kinase domain of RET with either the H4 (RET/PTC1) or the ELE1/RFG genes (RET/PTC3). PTEN codes for a dual-specificity phosphatase and maps to chromosome 10q22-23. Germline mutations confer susceptibility to Cowden syndrome whereas somatic mutations or deletions are common in several sporadic human tumors. Decreased PTEN expression has been implicated in thyroid cancer development. We report the characterization of a new chromosome 10 rearrangement involving H4 and PTEN. The initial H4/PTEN rearrangement was discovered as a non-specific product of RT-PCR for RET/PTC1 in irradiated thyroid cell lines. Sequencing revealed a transcript consisting of exon 1 and 2 of H4 fused with exons 3-6 of PTEN. Nested RT-PCR with specific primers bracketing the breakpoints confirmed the H4/PTEN rearrangements in irradiated KAT-1 and KAT-50 cells. Additional H4/PTEN variants, generated by recombination of either exon 1 or exon 2 of H4 with exon 6 of PTEN, were found in non-irradiated KAK-1, KAT-50, ARO and NPA cells. Their origin through chromosomal recombination was confirmed by detection of the reciprocal PTEN/H4 product. H4/PTEN recombination was not a clonal event in any of the cell lines, as Southern blots with appropriate probes failed to demonstrate aberrant bands, and multicolor FISH of KAK1 cells with BAC probes for H4 and PTEN did not show a signal overlap in all cells. Based on PCR of serially diluted samples, the minimal frequency of spontaneous recombination between these loci was estimated to be approximately 1/10{sup 6} cells. H4/PTEN products were found by nested RT-PCR in 4/14 normal thyroid tissues (28%) and 14/18 PTC (78%) (P < 0.01). H4/PTEN is another example of recombination involving the H4 locus, and points to the high susceptibility of thyroid cells to intrachromosomal gene rearrangements. As this also represents a

  8. Root cause of incomplete control rod insertions at Westinghouse reactors

    International Nuclear Information System (INIS)

    Ray, S.

    1997-01-01

    Within the past year, incomplete RCCA insertions have been observed on high burnup fuel assemblies at two Westinghouse PWRs. Initial tests at the Wolf Creek site indicated that the direct cause of the incomplete insertions observed at Wolf Creek was excessive fuel assembly thimble tube distortion. Westinghouse committed to the NRC to perform a root cause analysis by the end of August, 1996. The root cause analysis process used by Westinghouse included testing at ten sites to obtain drag, growth and other characteristics of high burnup fuel assemblies. It also included testing at the Westinghouse hot cell of two of the Wolf Creek incomplete insertion assemblies. A mechanical model was developed to calculate the response of fuel assemblies when subjected to compressive loads. Detailed manufacturing reviews were conducted to determine if this was a manufacturing related issue. In addition, a review of available worldwide experience was performed. Based on the above, it was concluded that the thimble tube distortion observed on the Wolf Creek incomplete insertion assemblies was caused by unusual fuel assembly growth over and above what would typically be expected as a result of irradiation exposure. It was determined that the unusual growth component is a combination of growth due to oxide accumulation and accelerated growth, and would only be expected in high temperature plants on fuel assemblies that see long residence times and high power duties

  9. Chromaticity correction in the TRISTAN phase I main ring with two types of insertion

    International Nuclear Information System (INIS)

    Wu, Yingzhi; Egawa, Kazumi.

    1984-07-01

    The TRISTAN main ring now under construction has four insertions. Besides the normal modes in which the four insertions have the same optics, the TRISTAN main ring will be operated in somewhat more complicated configurations with insertions having different optics. This report will consider chromaticity corrections using six families of sextupoles for the TRISTAN main ring with two different insertion types; opposite insertions have the same optics. The strength of correcting sextupoles is determined mainly using the W-correction method. The program PATRICIA is used to track the trajectories of test particles over 800 turns. The results show that the correction scheme adopted allows adequately large amplitudes of betatron and synchrotron oscillations. (author)

  10. A study of the suitability of ferrite for use in low-field insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.; Hassenzahl, W.V.

    1995-02-01

    Most insertion devices built to date use rare-earth permanent-magnet materials, which have a high remanent field and are more expensive than many other permanent-magnet materials. Low-field insertion devices could use less-expensive, lower performance magnetic materials if they had suitable magnetic characteristics. These materials must be resistant to demagnetization during construction and operation of the insertion device, have uniform magnetization, possess low minor-axis magnetic moments, and have small minor field components on the surfaces. This paper describes an investigation to determine if ferrite possesses magnetic qualities suitable for insertion device applications. The type of ferrite investigated, MMPA Ceramic 8 from Stackpole Inc., was found to be acceptable for insertion device applications.

  11. Alu Insertions and Genetic Diversity: A Preliminary Investigation by an Undergraduate Bioinformatics Class

    Science.gov (United States)

    Elwess, Nancy L.; Duprey, Stephen L.; Harney, Lindesay A.; Langman, Jessie E.; Marino, Tara C.; Martinez, Carolina; McKeon, Lauren L.; Moss, Chantel I. E.; Myrie, Sasha S.; Taylor, Luke Ryan

    2008-01-01

    "Alu"-insertion polymorphisms were used by an undergraduate Bioinformatics class to study how these insertion sites could be the basis for an investigation in human population genetics. Based on the students' investigation, both allele and genotype "Alu" frequencies were determined for African-American and Japanese populations as well as a…

  12. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  13. Chromosome intra- and inter-changes determined by G-banding in radiation workers with in vivo exposure to plutonium

    International Nuclear Information System (INIS)

    Tawn, E Janet; Whitehouse, Caroline A

    2005-01-01

    Suggestions that exposure to intakes of alpha-emitting radionuclides such as plutonium could result in a specific profile of chromosome damage distinguishable from that of low LET irradiation have led to the re-analysis of the different types of chromosome aberrations in peripheral blood lymphocytes determined by G-banding in a group of 20 plutonium workers from the British Nuclear Fuels plc facility at Sellafield, UK. Comparisons were made with a group of workers with negligible plutonium intakes but similar external gamma doses and with an unexposed control group. Examination of simple translocation frequencies in the three groups indicated a significant difference (P = 0.033), with the higher frequency in the plutonium workers indicating that exposure from plutonium was contributing to the aberration yield. Slightly raised frequencies of both intra-chromosomal and complex aberrations were observed in the plutonium workers in comparison with the comparable external exposure group and the control group but the difference did not reach significance at the P = 0.05 level and there was no variation in the relative frequencies of the different aberration types between the three groups. There was, therefore, no firm indication from this study that either intra-chromosomal or complex aberrations could be used as a specific marker of high LET exposure in workers with historical intakes of plutonium

  14. Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction.

    Science.gov (United States)

    Chang, Gang; Xia, Feng-Fei; Li, Hong-Fu; Niu, Su; Xu, Yuan-Shun

    2017-11-01

    To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.

  15. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  16. A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre

    OpenAIRE

    Roopal, Dr.; Bisht, Vandana

    2018-01-01

    Background: A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre.Methods: This prospective study was conducted among 100 women at tertiary care centre, Haldwani, Nainital. Patients were divided in to two groups. Group A (n=50)-post placental insertion within 10 minutes of delivery of placenta. Group B (n=50)-Interval insertion after 6 weeks of delivery. Both groups were compared in terms of pain abdomen, bleeding, missing thread, expulsion,...

  17. Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion.

    Science.gov (United States)

    Greinwald, Markus; Varady, Patrick A; Augat, Peter

    2017-12-14

    External fixation is associated with the risk of pin loosening and pin infection potentially associated to thermal bone necrosis during pin insertion. This study aims to investigate if the use of external fixator systems with unicortical pins reduces the heat production during pin insertion compared to fixators with bicortical pins. Porcine bone specimens were employed to determine bone temperatures during insertion of fixator pins. Two thermographic cameras were used for a simultaneous temperature measurement on the bone surface (top view) and a bone cross-section (front view). Self-drilling unicortical and bicortical pins were inserted at different rotational speeds: (30-600) rpm. Maximum and mean temperatures of the emerging bone debris, bone surface and bone cross-section were analyzed. Maximum temperatures of up to 77 ± 26 °C were measured during pin insertion in the emerging debris and up to 42 ± 2 °C on the bone surface. Temperatures of the emerging debris increased with increasing rotational speeds. Bicortical pin insertion generated significantly higher temperatures at low insertion speed (30 rpm) CONCLUSION: The insertion of external fixator pins can generate a considerable amount of heat around the pins, primarily emerging from bone debris and at higher insertion speeds. Our findings suggest that unicortical, self-drilling fixator pins have a decreased risk for thermal damage, both to the surrounding tissue and to the bone itself.

  18. Functional PMS2 hybrid alleles containing a pseudogene-specific missense variant trace back to a single ancient intrachromosomal recombination event.

    Science.gov (United States)

    Ganster, Christina; Wernstedt, Annekatrin; Kehrer-Sawatzki, Hildegard; Messiaen, Ludwine; Schmidt, Konrad; Rahner, Nils; Heinimann, Karl; Fonatsch, Christa; Zschocke, Johannes; Wimmer, Katharina

    2010-05-01

    Sequence exchange between PMS2 and its pseudogene PMS2CL, embedded in an inverted duplication on chromosome 7p22, has been reported to be an ongoing process that leads to functional PMS2 hybrid alleles containing PMS2- and PMS2CL-specific sequence variants at the 5'-and the 3'-end, respectively. The frequency of PMS2 hybrid alleles, their biological significance, and the mechanisms underlying their formation are largely unknown. Here we show that overall hybrid alleles account for one-third of 384 PMS2 alleles analyzed in individuals of different ethnic backgrounds. Depending on the population, 14-60% of hybrid alleles carry PMS2CL-specific sequences in exons 13-15, the remainder only in exon 15. We show that exons 13-15 hybrid alleles, named H1 hybrid alleles, constitute different haplotypes but trace back to a single ancient intrachromosomal recombination event with crossover. Taking advantage of an ancestral sequence variant specific for all H1 alleles we developed a simple gDNA-based polymerase chain reaction (PCR) assay that can be used to identify H1-allele carriers with high sensitivity and specificity (100 and 99%, respectively). Because H1 hybrid alleles harbor missense variant p.N775S of so far unknown functional significance, we assessed the H1-carrier frequency in 164 colorectal cancer patients. So far, we found no indication that the variant plays a major role with regard to cancer susceptibility. (c) 2010 Wiley-Liss, Inc.

  19. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  20. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  1. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  2. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  3. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    Science.gov (United States)

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Design and testing of microfabricated surgical tools for large animal probe insertion

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, Shelly [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-08-05

    Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion for a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (Pcr) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the Pcr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same Pcr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful

  5. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-27

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  6. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  7. Effects of lithium insertion on thermal conductivity of silicon nanowires

    International Nuclear Information System (INIS)

    Xu, Wen; Zhang, Gang; Li, Baowen

    2015-01-01

    Recently, silicon nanowires (SiNWs) have been applied as high-performance Li battery anodes, since they can overcome the pulverization and mechanical fracture during lithiation. Although thermal stability is one of the most important parameters that determine safety of Li batteries, thermal conductivity of SiNWs with Li insertion remains unclear. In this letter, using molecular dynamics simulations, we study room temperature thermal conductivity of SiNWs with Li insertion. It is found that compared with the pristine SiNW, there is as much as 60% reduction in thermal conductivity with 10% concentration of inserted Li atoms, while under the same impurity concentration the reduction in thermal conductivity of the mass-disordered SiNW is only 30%. With lattice dynamics calculations and normal mode decomposition, it is revealed that the phonon lifetimes in SiNWs decrease greatly due to strong scattering of phonons by vibrational modes of Li atoms, especially for those high frequency phonons. The observed strong phonon scattering phenomenon in Li-inserted SiNWs is similar to the phonon rattling effect. Our study serves as an exploration of thermal properties of SiNWs as Li battery anodes or weakly coupled with impurity atoms

  8. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  9. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  10. Impact of Fixed-Bearing and Mobile-Bearing Tibial Insert in Unicondylar Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mehmet Faruk Çatma

    2016-06-01

    Full Text Available INTRODUCTION: The aim of the study is to investigate the impact of fixed or mobile-bearing tibial inserts on patellofemoral arthrosis and evaluate which one to be preferred for patients with patellofemoral arthrosis. METHODS: Operated in our clinic between January 2009 and February 2013, 33 with patellofemoral arthritis together with anteromedial compartment arthritis were included in the study. Patellofemoral joints of patients were evaluated according to the scoring system defined by Fulkerson-Shea. RESULTS: Unicondylar knee arthroplasty with fixed-bearing tibial insertsand 22 (66,6% (male: 3, female: 19 and unicondylar knee arthroplasty with mobile-bearing tibial inserts 11 (33,9 % (male: 2, female: 9 were implanted.Average knee flexion was found to be 116,5 (100-135 degrees in 22 patients with mobile-bearing tibial inserts, and 114,5 (95-135 in 11 patients with fixed-bearing tibial inserts. DISCUSSION AND CONCLUSION: Patellofemoral arthrosis is an important factor for unicondylar knee arthroplasty prognosis and one of the determinants of patient satisfaction. Significantly less patellofemoral complaints were seen with UKA with fixed-bearing tibial insert compared to mobile-bearing tibial insert.

  11. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  12. A study on the resistance at bone-implant interface during implant insertion in a cadaver goat jaw model

    Directory of Open Access Journals (Sweden)

    Goutam Das

    2016-01-01

    Full Text Available Background: The aim of the study is to determine the resistance at bone-implant interface during insertion of dental implant. Materials and Methods: Freshly procured cadaver goat mandibles were collected from slaughterhouses. Four dental implants of two different diameters were inserted into osteotomized sites of the goat mandibles. The gradual changes in resonance frequency (RF were recorded in RF analyzer for the five consecutive turns of implant insertion. Results and Observations: RF was found to be positively correlated with diameter of dental implants. Conclusion: RF analysis can be used to determine the type of resistance the implant faces during insertion and the kind of bone density through which it passes. It gives a forecast of expected initial stability.

  13. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  14. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  15. Technical note: Computer-manufactured inserts for prosthetic sockets.

    Science.gov (United States)

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  17. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  18. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  19. Method Of Wire Insertion For Electric Machine Stators

    Science.gov (United States)

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  20. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  1. Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation. Short-term observation

    International Nuclear Information System (INIS)

    Mizuno, Koichi; Shinomiya, Kenichi; Otani, Kazuyuki

    2005-01-01

    The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined. (author)

  2. Field errors in hybrid insertion devices

    International Nuclear Information System (INIS)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed

  3. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  4. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  5. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    Science.gov (United States)

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (preadability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  6. Relationship of the Van Herick Grading System with Peripheral Iris Configuration and Level of Iris Insertion.

    Science.gov (United States)

    Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman

    2017-09-01

    To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.

  7. Human Kinematics of Cochlear Implant Surgery: An Investigation of Insertion Micro-Motions and Speed Limitations.

    Science.gov (United States)

    Kesler, Kyle; Dillon, Neal P; Fichera, Loris; Labadie, Robert F

    2017-09-01

    Objectives Document human motions associated with cochlear implant electrode insertion at different speeds and determine the lower limit of continuous insertion speed by a human. Study Design Observational. Setting Academic medical center. Subjects and Methods Cochlear implant forceps were coupled to a frame containing reflective fiducials, which enabled optical tracking of the forceps' tip position in real time. Otolaryngologists (n = 14) performed mock electrode insertions at different speeds based on recommendations from the literature: "fast" (96 mm/min), "stable" (as slow as possible without stopping), and "slow" (15 mm/min). For each insertion, the following metrics were calculated from the tracked position data: percentage of time at prescribed speed, percentage of time the surgeon stopped moving forward, and number of direction reversals (ie, going from forward to backward motion). Results Fast insertion trials resulted in better adherence to the prescribed speed (45.4% of the overall time), no motion interruptions, and no reversals, as compared with slow insertions (18.6% of time at prescribed speed, 15.7% stopped time, and an average of 18.6 reversals per trial). These differences were statistically significant for all metrics ( P implant electrode at 15 mm/min is not feasible for human operators. The lower limit of continuous forward insertion is 52 mm/min on average. Guidelines on manual insertion kinematics should consider this practical limit of human motion.

  8. Peripherally inserted central catheters and upper extremity deep vein thrombosis

    International Nuclear Information System (INIS)

    Ong, B.; Gibbs, H.; Catchpole, I.; Hetherington, R.; Harper, J.

    2006-01-01

    The purpose of the study was to determine the incidence and risk factors for venous thrombosis in patients with a peripherally inserted central catheter (PICC). A retrospective study of all upper extremity venous duplex scans was carried out in the Vascular Medicine department from year 2000 to 2002 inclusive. A chart review of positive scans was undertaken to identify possible thrombotic risk factors. Of 317 upper extremity venous duplex scans carried out, 115, or 32%, were positive for upper extremity deep vein thrombosis. Three main risk factors were identified - presence of a central line, malignancy and administration of chemotherapy. PICC were the most common central line present. Symptomatic thrombosis occurred in 7% of PICC inserted for chemotherapy compared with 1% of PICC inserted for other reasons. Ten per cent of the patients receiving chemotherapy through a PICC developed a thrombosis. The post-thrombotic syndrome was infrequent following upper extremity deep vein thrombosis. Patients receiving chemotherapy through a PICC are at increased risk of thrombosis. There may be a role for prophylactic low-dose anticoagulation in these high-risk patients

  9. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  10. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  11. Immunological evaluation of polystyrene and poly(ether imide) cell culture inserts with different roughness.

    Science.gov (United States)

    Roch, Toralf; Krüger, Anne; Kratz, Karl; Ma, Nan; Jung, Friedrich; Lendlein, Andreas

    2012-01-01

    For the successful clinical and biological application of polymers, their interaction with cells, tissues, and body fluids has to be well characterized. In order to investigate how the physical, chemical, and mechanical properties of candidate biomaterials influence cell behaviours, the testing sample is usually placed in commercially available cell culture plates. Thus, not only the testing sample itself but also the culture dish material might influence the cell behaviour. Therefore, an insert system was created to exclude this influence and allow investigations of the testing material solely. In this study micropatterned inserts prepared from polystyrene (PS) as well as from poly(ether imide) (PEI) with three different roughness levels of i) Rq = 0.29 μm (PS) and 0.23 μm (PEI); ii) Rq = 3.47 μm (PS) and 3.92 μm (PEI); and iii) Rq = 22.16 μm [corrected] (PS) and 22.65 μm (PEI) were explored with regard of their immuno-compatibility including the determination of potential contaminations with endotoxins or other microbial products. The endotoxin levels of the inserts were determined to be less than 0.07 EU/mL, which is well below the U.S. Food and Drug Administration limit of 0.5 EU/mL and the survival of murine macrophages cultured in the inserts was not impaired. Activation of early immune mechanisms such as complement activation and the generation of reactive oxygen species could not be observed. All tested materials had no influence on the cytokine secretion from cells of whole human blood. The investigated inserts were immuno-compatible and apparently free of contaminations with microbial products. The roughness of the inserts had no stimulatory or inhibitory effect on early immune mechanisms. Conclusively, the 24-well plate insert systems introduced in this study allow investigating the interactions of tailored surface properties such as roughness with many other cell types, without the disadvantage of the standard commercially available culture

  12. Effect of a flow-corrective insert on the flow pattern in a pebble bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yu; Gui, Nan; Yang, Xingtuan [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing 100084 (China); Tu, Jiyuan [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing 100084 (China); School of Aerospace, Mechanical & Manufacturing Engineering, RMIT University, Melbourne 3083, VIC (Australia); Jiang, Shengyao, E-mail: shengyaojiang@sina.com [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing 100084 (China)

    2016-04-15

    Highlights: • Effect of an insert on improving flow uniformity and eliminating stagnant zone is studied. • Three values concerned with the stagnant zone, radial uniformity and flow sequence are used. • Outlet diameter is a critical parameter that determines balancing mechanism of the insert. • Height/location is varied to let the insert work in unbalanced region and avoid adverse effect. - Abstract: A flow-corrective insert is adopted in the pebble-bed high temperature gas-cooled reactor (HTGR) to improve flow performance of the pebble flow for the first time. 3D discrete element method (DEM) modeling is employed to study this slow and dense granular flow. It is verified that locating a properly designed insert in the bed can help transform unsatisfactory flow field to the preferred flow pattern for pebble bed reactors. Three characteristic values on the stagnant zone, radial uniformity and flow sequence of pebble flow are defined to evaluate uniformity of the overall flow field quantitatively. The results demonstrate that the pebble bed equipped with an insert performs better than normal beds from all these three aspects. Moreover, based on numerical experiments, several universal tips for insert design on height, location and outlet diameter are suggested.

  13. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  14. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  15. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  16. Effect of heavy-metal insertions at Fe/MgO interfaces on electric-field-induced modification of magnetocrystalline anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K.; Nomura, T. [Department of Physics Engineering, Mie University, Tsu, Mie 514-8507 (Japan); Pradipto, A.-M. [Department of Physics Engineering, Mie University, Tsu, Mie 514-8507 (Japan); Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Nawa, K.; Akiyama, T.; Ito, T. [Department of Physics Engineering, Mie University, Tsu, Mie 514-8507 (Japan)

    2017-05-01

    Magnetocrystalline anisotropy (MCA) at Fe/MgO interfaces with insertions of 3d (Co, Ni), 4d (Ru, Rh, Pd), and 5d (Os, Ir, Pt) elements in external electric fields was investigated from first-principles calculations. The MCA energy and the electric-field-induced MCA modification dramatically depend on the inserted elements. Large MCA modification may be achieved by heavy-metal insertions, in which the strength of spin-orbit coupling of inserted elements and the position of the Fermi level relative to d band level play key roles. - Highlights: • MCA at Fe/MgO interface dramatically depends on insertions of 3d, 4d, and 5d elements. • Large electric-field-induced MCA modification is achieved by heavy-metal insertions. • Position of Fermi level relative to d band level plays key role in determining MCA.

  17. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    Science.gov (United States)

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Target-matched insertion gain derived from three different hearing aid selection procedures.

    Science.gov (United States)

    Punch, J L; Shovels, A H; Dickinson, W W; Calder, J H; Snead, C

    1995-11-01

    Three hearing aid selection procedures were compared to determine if any one was superior in producing prescribed real-ear insertion gain. For each of three subject groups, 12 in-the-ear style hearing aids with Class D circuitry and similar dispenser controls were ordered from one of three manufacturers. Subject groups were classified based on the type of information included on the hearing aid order form: (1) the subject's audiogram, (2) a three-part matrix specifying the desired maximum output, full-on gain, and frequency response slope of the hearing aid, or (3) the desired 2-cc coupler full-in grain of the hearing aid, based on real-ear coupler difference (RECD) measurements. Following electroacoustic adjustments aimed at approximating a commonly used target insertion gain formula, results revealed no significant differences among any of the three selection procedures with respect to obtaining acceptable insertion gain values.

  19. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    Science.gov (United States)

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  20. Generation and analysis of a barcode-tagged insertion mutant library in the fission yeast Schizosaccharomyces pombe

    Science.gov (United States)

    2012-01-01

    Background Barcodes are unique DNA sequence tags that can be used to specifically label individual mutants. The barcode-tagged open reading frame (ORF) haploid deletion mutant collections in the budding yeast Saccharomyces cerevisiae and the fission yeast Schizosaccharomyces pombe allow for high-throughput mutant phenotyping because the relative growth of mutants in a population can be determined by monitoring the proportions of their associated barcodes. While these mutant collections have greatly facilitated genome-wide studies, mutations in essential genes are not present, and the roles of these genes are not as easily studied. To further support genome-scale research in S. pombe, we generated a barcode-tagged fission yeast insertion mutant library that has the potential of generating viable mutations in both essential and non-essential genes and can be easily analyzed using standard molecular biological techniques. Results An insertion vector containing a selectable ura4+ marker and a random barcode was used to generate a collection of 10,000 fission yeast insertion mutants stored individually in 384-well plates and as six pools of mixed mutants. Individual barcodes are flanked by Sfi I recognition sites and can be oligomerized in a unique orientation to facilitate barcode sequencing. Independent genetic screens on a subset of mutants suggest that this library contains a diverse collection of single insertion mutations. We present several approaches to determine insertion sites. Conclusions This collection of S. pombe barcode-tagged insertion mutants is well-suited for genome-wide studies. Because insertion mutations may eliminate, reduce or alter the function of essential and non-essential genes, this library will contain strains with a wide range of phenotypes that can be assayed by their associated barcodes. The design of the barcodes in this library allows for barcode sequencing using next generation or standard benchtop cloning approaches. PMID:22554201

  1. Generation and analysis of a barcode-tagged insertion mutant library in the fission yeast Schizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Chen Bo-Ruei

    2012-05-01

    Full Text Available Abstract Background Barcodes are unique DNA sequence tags that can be used to specifically label individual mutants. The barcode-tagged open reading frame (ORF haploid deletion mutant collections in the budding yeast Saccharomyces cerevisiae and the fission yeast Schizosaccharomyces pombe allow for high-throughput mutant phenotyping because the relative growth of mutants in a population can be determined by monitoring the proportions of their associated barcodes. While these mutant collections have greatly facilitated genome-wide studies, mutations in essential genes are not present, and the roles of these genes are not as easily studied. To further support genome-scale research in S. pombe, we generated a barcode-tagged fission yeast insertion mutant library that has the potential of generating viable mutations in both essential and non-essential genes and can be easily analyzed using standard molecular biological techniques. Results An insertion vector containing a selectable ura4+ marker and a random barcode was used to generate a collection of 10,000 fission yeast insertion mutants stored individually in 384-well plates and as six pools of mixed mutants. Individual barcodes are flanked by Sfi I recognition sites and can be oligomerized in a unique orientation to facilitate barcode sequencing. Independent genetic screens on a subset of mutants suggest that this library contains a diverse collection of single insertion mutations. We present several approaches to determine insertion sites. Conclusions This collection of S. pombe barcode-tagged insertion mutants is well-suited for genome-wide studies. Because insertion mutations may eliminate, reduce or alter the function of essential and non-essential genes, this library will contain strains with a wide range of phenotypes that can be assayed by their associated barcodes. The design of the barcodes in this library allows for barcode sequencing using next generation or standard benchtop cloning

  2. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  3. Report on converging insert moulding with µ-IM

    DEFF Research Database (Denmark)

    Islam, Aminul

    moulding with µ-IM  Task 5.2.1 and COTECH demonstrator: guide line for 5PRC production based on the concept of Task 5.2.1 Information and results provided by this deliverable will be directly used for one of the COTECH demonstrators production which will call for convergent insert moulding with µ......Task 5.2.1 deals with the technical feasibility of converging the state-of-the-art µ IM process with insert moulding to offer a wide range of multi-material µ components. The main objective of this deliverable is to summarize state-of-the-art information and to make the guideline needed...... for the convergence. In particular the following aspects are summed up in the deliverable:  Need for converging insert moulding with µ-IM  Objectives and expected outcome from task 5.2.1  State-of-the-art micro insert moulding and different scenario of micro insert moulding  Challenges ahead of converging insert...

  4. Reversible alkyne insertion in the benzannulation reaction of Fischer carbene complexes with alkynes

    Energy Technology Data Exchange (ETDEWEB)

    Waters, M.L.; Bos, M.E.; Wulff, W.D. [Univ. of Chicago, IL (United States)

    1995-12-31

    The benzannulation reaction of Fischer carbene complexes with alkynes to give phenols is highly regioselective with terminal alkynes, and reasonably regioselective with internal alkynes. This has been attributed to steric factors in intermediates, where one form is favored due to close contact between the R substituent and a cis-CO ligand. Whether alkyne insertion is kinetically or thermodynamically controlled has not been determined. The authors now have evidence from regioselectivity studies that alkyne insertion into the metal-carbon bond is reversible. Implications of these results and further mechanistic considerations will be presented.

  5. Machinability and scratch wear resistance of carbon-coated WC inserts

    Energy Technology Data Exchange (ETDEWEB)

    Pazhanivel, B., E-mail: palcecri@yahoo.co.in; Kumar, T. Prem; Sozhan, G.

    2015-03-15

    Highlights: • Cemented WC inserts were coated with carbon by CVD. • The deposits were either loosely held MWCNTs or adherent carbides. • Co-efficient of friction (ramp load; 1–13 N); 0.2 and 0.1 μ, respectively, for the uncoated and carbide-coated inserts. • The carbide-coated insert exhibited better machinability and surface finish than a commercial TiCN-coated insert. - Abstract: In this work, cemented tungsten carbide (WC) inserts were coated with nanocarbons/carbides by chemical vapor deposition (CVD) and their machinability and scratch wear resistance were investigated. The hardness and surface conditions of the WC substrate were studied before and after coating. The CVD-generated nanocarbons on the insert surfaces were examined by SEM, FE-SEM and TEM. The electron microscopic images revealed that the carbons generated were multi-walled carbon nanotubes (MWCNTs) or carbides depending on the experimental conditions. In both the cases, the cutting edges of the inserts had dense deposits. Scratch wear test with the coated inserts showed that the co-efficient of friction was 0.1 μ as against 0.2 μ for the uncoated inserts under a ramp load of 1–13 N. The machinability characteristics of commercially available TiCN-coated inserts and the carbon-coated WC inserts were compared by using a CNC machine and a Rapid I vision inspection system. It was found that the carbide-coated inserts exhibited machinability with better surface finish comparable to that of the TiCN-coated inserts while the MWCNT-coated inserts showed inferior adhesion properties.

  6. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  7. Pericentric intrachromosomal insertion responsible for recurrence of del(11)(p13p14) in a family

    NARCIS (Netherlands)

    Henry, I.; Hoovers, J.; Barichard, F.; Berthéas, M. F.; Puech, A.; Prieur, F.; Gessler, M.; Bruns, G.; Mannens, M.; Junien, C.

    1993-01-01

    The combined use of qualitative and quantitative analysis of 11p13 polymorphic markers together with chromosomal in situ suppression hybridization (CISS) with biotin labeled probes mapping to 11p allowed us to characterize a complex rearrangement segregating in a family. We detected a pericentric

  8. Recurrence, submicroscopic complexity, and potential clinical relevance of copy gains detected by array CGH that are shown to be unbalanced insertions by FISH.

    Science.gov (United States)

    Neill, Nicholas J; Ballif, Blake C; Lamb, Allen N; Parikh, Sumit; Ravnan, J Britt; Schultz, Roger A; Torchia, Beth S; Rosenfeld, Jill A; Shaffer, Lisa G

    2011-04-01

    Insertions occur when a segment of one chromosome is translocated and inserted into a new region of the same chromosome or a non-homologous chromosome. We report 71 cases with unbalanced insertions identified using array CGH and FISH in 4909 cases referred to our laboratory for array CGH and found to have copy-number abnormalities. Although the majority of insertions were non-recurrent, several recurrent unbalanced insertions were detected, including three der(Y)ins(Y;18)(q?11.2;p11.32p11.32)pat inherited from parents carrying an unbalanced insertion. The clinical significance of these recurrent rearrangements is unclear, although the small size, limited gene content, and inheritance pattern of each suggests that the phenotypic consequences may be benign. Cryptic, submicroscopic duplications were observed at or near the insertion sites in two patients, further confounding the clinical interpretation of these insertions. Using FISH, linear amplification, and array CGH, we identified a 126-kb duplicated region from 19p13.3 inserted into MECP2 at Xq28 in a patient with symptoms of Rett syndrome. Our results demonstrate that although the interpretation of most non-recurrent insertions is unclear without high-resolution insertion site characterization, the potential for an otherwise benign duplication to result in a clinically relevant outcome through the disruption of a gene necessitates the use of FISH to determine whether copy-number gains detected by array CGH represent tandem duplications or unbalanced insertions. Further follow-up testing using techniques such as linear amplification or sequencing should be used to determine gene involvement at the insertion site after FISH has identified the presence of an insertion.

  9. Test manufacture of the canister insert 135

    International Nuclear Information System (INIS)

    Raiko, H.

    2005-10-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Foundries Jyvaeskylae Oy, in June 2004 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the second trial manufacture of this type of insert in Finland and, in total, the third test manufacture of insert by Metso Foundries Jyvaeskylae Oy. The result fulfilled all the requirements but the material mechanical properties of the cast material. The measured ultimate strength and elongation at rupture were lower than specified in the upper part of the cast. The reason for this was revealed in the metallurgical investigation of the cast material. The cast contained slag (dross). Avoiding the dross formation will be the most demanding challenge of the forthcoming development of the cast procedure. (orig.)

  10. A macaque's-eye view of human insertions and deletions: differences in mechanisms.

    Directory of Open Access Journals (Sweden)

    Erika M Kvikstad

    2007-09-01

    Full Text Available Insertions and deletions (indels cause numerous genetic diseases and lead to pronounced evolutionary differences among genomes. The macaque sequences provide an opportunity to gain insights into the mechanisms generating these mutations on a genome-wide scale by establishing the polarity of indels occurring in the human lineage since its divergence from the chimpanzee. Here we apply novel regression techniques and multiscale analyses to demonstrate an extensive regional indel rate variation stemming from local fluctuations in divergence, GC content, male and female recombination rates, proximity to telomeres, and other genomic factors. We find that both replication and, surprisingly, recombination are significantly associated with the occurrence of small indels. Intriguingly, the relative inputs of replication versus recombination differ between insertions and deletions, thus the two types of mutations are likely guided in part by distinct mechanisms. Namely, insertions are more strongly associated with factors linked to recombination, while deletions are mostly associated with replication-related features. Indel as a term misleadingly groups the two types of mutations together by their effect on a sequence alignment. However, here we establish that the correct identification of a small gap as an insertion or a deletion (by use of an outgroup is crucial to determining its mechanism of origin. In addition to providing novel insights into insertion and deletion mutagenesis, these results will assist in gap penalty modeling and eventually lead to more reliable genomic alignments.

  11. Progesterone inserts may help to improve breeding readiness in beef heifers

    OpenAIRE

    Favetto, Pedro H; Hoar, Bruce R; Myers, Dan M; Tindall, Justin

    2010-01-01

    The accurate determination of pubertal status in yearling beef heifers, possibly combined with the use of exogenous progesterone, allows females to produce the maximum number of calves over their lifetimes. This study aimed to determine the reliability of a reproductive tract scoring (RTS) system that combines manual palpation with ultrasound as a measure of pubertal status, and whether the treatment of heifers with progesterone-containing vaginal inserts — followed by breeding on the second ...

  12. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  13. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  14. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  15. Reorientation simplified: A device for recording and reproducing the path of insertion for removable partial dentures

    Directory of Open Access Journals (Sweden)

    Vaibhav D Kamble

    2014-01-01

    Full Text Available Aim: The record of path of insertion on the dental cast is part of the dentist′s work authorization to the dental laboratory technician. The path of insertion record enables the dental technician to replace the cast on a surveyor in the same position that the dentist selected. Analysis of factors that influence the path of insertion should determine a path of insertion that will reduce the potential for dislodgement and promote stability of removable partial denture (RPD. Materials and Methods: The recording of the relation of a cast to a dental surveyor and the transfer of this relationship to the dental laboratory may be done by tripodization, by scoring the base of the cast, or by cementing a reference pin on the cast. Conclusion: Recording the established path of insertion can be difficult when the procedure uses a cemented pin and the casts are mounted in an articulator. This article describes a procedure for innovative dowel pin and sleeve device to record the path of insertion of RPDs, which serves the same purpose as the cemented pin but can be easily removed and replaced.

  16. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  17. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  18. Laparoscopic insertion of the Moss feeding tube.

    Science.gov (United States)

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  19. Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.

    Science.gov (United States)

    Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H

    2018-03-14

    The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.

  20. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb$_{3}$Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb$_{3}$Sn m...

  1. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  2. Lithium insertion mechanism in SnS2

    International Nuclear Information System (INIS)

    Lefebvre-Devos, I.; Olivier-Fourcade, J.; Jumas, J.C.; Lavela, P.

    2000-01-01

    We study lithium insertion in SnS 2 by means of 119 Sn Moessbauer spectroscopy, x-ray absorption spectroscopy at Sn L I,III , and S K edges, and theoretical electronic structures (calculated in the density-functional theory framework). An insertion mechanism is derived according to the Li amount. It shows the influence of the SnS 2 -layered structure on the Sn reduction, particularly the possibility of an intermediate oxidation state between Sn IV and Sn II , which is not observed during Li insertion in three-dimensional sulfides

  3. Machine-vision-based identification of broken inserts in edge profile milling heads

    NARCIS (Netherlands)

    Fernandez Robles, Laura; Azzopardi, George; Alegre, Enrique; Petkov, Nicolai

    This paper presents a reliable machine vision system to automatically detect inserts and determine if they are broken. Unlike the machining operations studied in the literature, we are dealing with edge milling head tools for aggressive machining of thick plates (up to 12 centimetres) in a single

  4. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  5. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  6. The effect of increased CRA trip insertion times for TMI

    International Nuclear Information System (INIS)

    Irani, A.; Link, J.; Trikouos, N.

    1996-01-01

    In recent years, testing of control rod assembly (CRA) drop times at TMI has resulted in a few rods that have failed to meet the Technical Specification (TS) acceptance criteria of 1.66 seconds to 3/4 inserted. Crud deposition was determined to be the cause of the slow rod insertion times. Corrective actions included increasing lithium concentration and increasing the frequency and extent of exercising the control rod drive mechanisms. However, after one cycle of operation, it was determined that these measures were not fully successful in retarding the crud buildup. Consequently, the safety significance of rods potentially having a longer drop time than the TS limit was evaluated. The analyses in Chapter 14 of the TMI FSAR demonstrate the ability of the plant to mitigate the consequences of postulated accidents without undue hazard to the health and safety of the public. To determine the safety consequences of the longer rod drop times, a reanalysis of some limiting accidents had to be done using the RETRAN, RELAP5 and TRAC computer codes. The safety evaluation concluded that a 3.0 second rod drop time would be acceptable because all of the event acceptance criteria were met. A permanent resolution of the problem is the replacement of the existing thermal barriers with new open flow path thermal barriers. Thermal barriers on half the CRAs at TMI have been replaced to date

  7. Chronic insertional Achilles tendinopathy: surgical outcomes

    OpenAIRE

    Oshri, Yael; Palmanovich, Ezequiel; Brin, Yaron Shagra; Karpf, Ronen; Massarwe, Sabri; Kish, Benny; Nyska, Meir

    2012-01-01

    Background and objective: insertional Achilles tendinopathy is a common condition among athletes and joggers. One fifth of the injuries involves the insertion of the tendon. The etiology is either due to mechanical overuse related to sports activity, or a systemic inflammatory disease. The clinical appearance includes pain and movement restriction. The primary treatment is conservative. The surgery referred to in this study (Calcaneal Osteotomy) is performed by decompression of the posterior ...

  8. Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients.

    Science.gov (United States)

    Gnannt, Ralph; Connolly, Bairbre L; Parra, Dimitri A; Amaral, Joao; Moineddin, Rahim; Thakor, Avnesh S

    2016-10-01

    The position of the tip of a peripherally inserted central catheter (PICC) is crucial; malposition can lead to malfunction of the line or life-threatening events (e.g., arrhythmias, perforation). To determine what factors other than arm position and accessed vein might influence the tip position of a PICC. Inclusion criteria were upper limb PICC placement, body weight central tip movement in rib units. We included 112 children who received a PICC (42 girls/70 boys, mean age 31±13 months, mean weight 6.5±4.9 kg). The overall range of central tip movement was -1 to +4 rib units (mean +0.8±0.7 rib units). Silicone PICCs moved significantly less than polyurethane PICCs (Pcentral tip movement of a PICC (P>0.05). Silicone PICCs and PICCs inserted into the cephalic vein move less than PICCs made of polyurethane and PICCs inserted into the brachial and basilic veins. These findings might assist operators in deciding which PICC to place in children in a given clinical context.

  9. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  10. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  11. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  12. Effect of fiber inserts on gingival margin microleakage of Class II bulk-fill composite resin restorations.

    Science.gov (United States)

    Shafiei, Fereshteh; Doozandeh, Maryam; Karimi, Vahid

    2018-01-01

    This study evaluated the effect of fiber inserts combined with composite resins on enamel and dentin margin microleakage. The fiber inserts were used with high- (x-tra fil) and low-viscosity (x-tra base) bulk-fill composite resins and as well as conventional composite resins (Grandio and Grandio Flow). In 96 sound, recently extracted molars, 2 standardized Class II cavities were prepared. The teeth were randomly divided into 8 groups of 12 teeth each, based on composite resin type and presence or absence of fiber inserts: groups 1 and 2, x-tra fil with and without fiber inserts, respectively; groups 3 and 4, x-tra base with and without fiber inserts; groups 5 and 6, Grandio with and without fiber inserts; and groups 7 and 8, Grandio Flow liner (gingival floor)/Grandio (remainder of cavity) with and without fiber inserts. In all the groups, a 2-step etch-and-rinse adhesive was used. The specimens were processed in a dye penetration technique to determine microleakage percentages. Data were analyzed with analysis of variance, Tukey, and t tests. There was significantly less leakage at the enamel margins than the dentin margins. Fiber reinforcement significantly decreased enamel microleakage in all the groups, with no significant differences among the groups. Concerning dentin microleakage, there were no significant differences among the 4 groups without fiber inserts, while a significant difference was detected in groups 2 (x-tra fil plus fiber) and 8 (Grandio Flow plus fiber/Grandio). Fibers significantly improved dentin sealing in groups 2 and 8. These findings suggest that a fiber insert reinforcing bulk-fill and conventional composite resins might improve enamel sealing in shallow Class II cavi-ties. The effect of fiber reinforcement on the dentin margins of deep cavities depended on the viscosity of the composite resins; fiber reinforcement was effective for flowable bulk-fill and conventional composite resin restorations.

  13. Insertion compounds of transition-metal and uranium oxides

    International Nuclear Information System (INIS)

    Chippindale, A.M.; Dickens, P.G.; Powell, A.V.

    1991-01-01

    Several transition-metal and actinide oxides, in which the metal occurs in a high oxidation state, have open covalent structures and are capable of incorporating alkali and other electropositive metals under mild conditions to form insertion compounds A x MO n . These are solids which have several features in common: Over a range of compositions, A x MO n exists as one or more stable or metastable phases in which the structure of the parent oxide MO n is largely retained and the insertion element A is accommodated interstitially. Insertion is accompanied by a redox process A=A i . + e - M in which M is reduced and the electronic properties of the parent oxide change to those typical of a mixed-valence compound. The insertion process xA + MO n = A x MO n can be reversed, at least to some extent, by chemical or electrochemical reaction, with retention of structure (topotactic reaction). This review concentrates on methods of synthesis, characterisation, crystal structure and thermochemistry of these insertion compounds. It updates and extends previous work. (author)

  14. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  15. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  16. Prediction of dynamic cutting force and regenerative chatter stability in inserted cutters milling

    Science.gov (United States)

    Li, Zhongqun; Liu, Qiang; Yuan, Songmei; Huang, Kaisheng

    2013-05-01

    Currently, the modeling of cutting process mainly focuses on two aspects: one is the setup of the universal cutting force model that can be adapted to a broader cutting condition; the other is the setup of the exact cutting force model that can accurately reflect a true cutting process. However, there is little research on the prediction of chatter stablity in milling. Based on the generalized mathematical model of inserted cutters introduced by ENGIN, an improved geometrical, mechanical and dynamic model for the vast variety of inserted cutters widely used in engineering applications is presented, in which the average directional cutting force coefficients are obtained by means of a numerical approach, thus leading to an analytical determination of stability lobes diagram (SLD) on the axial depth of cut. A new kind of SLD on the radial depth of cut is also created to satisfy the special requirement of inserted cutter milling. The corresponding algorithms used for predicting cutting forces, vibrations, dimensional surface finish and stability lobes in inserted cutter milling under different cutting conditions are put forward. Thereafter, a dynamic simulation module of inserted cutter milling is implemented by using hybrid program of Matlab with Visual Basic. Verification tests are conducted on a vertical machine center for Aluminum alloy LC4 by using two different types of inserted cutters, and the effectiveness of the model and the algorithm is verified by the good agreement of simulation result with that of cutting tests under different cutting conditions. The proposed model can predict the cutting process accurately under a variety of cutting conditions, and a high efficient and chatter-free milling operation can be achieved by a cutting condition optimization in industry applications.

  17. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  18. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  19. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  20. Clinical Impact of Prophylactic Antibiotic Treatment for Self-Expandable Metallic Stent Insertion in Patients with Malignant Colorectal Obstruction

    Directory of Open Access Journals (Sweden)

    Jong-Sun Kim

    2015-01-01

    Full Text Available Purpose. The aim of this study was to determine the efficacy of prophylactic antibiotics (PA for reducing the infectious complications and the potential risk factors responsible for the infectious complications after stent insertion for malignant colorectal obstruction. Methods. We performed a retrospective review of 224 patients who underwent self-expandable metallic stent (SEMS insertion for malignant colorectal obstruction from May 2004 to December 2012. Results. There were 145 patients in the PA group and 79 in non-PA group. The CRP level in PA group was significantly higher than that in non-PA. Abdominal tenderness and mechanical ileus were significantly more frequent in PA group than those in non-PA. The frequency of post-SEMS insertion fever, systemic inflammatory response syndrome (SIRS, and bacteremia was not significantly different between PA and non-PA groups. In multivariate analysis, the CRP level was risk factor related to post-SEMS insertion SIRS. However, in propensity score matching analysis, there was no independent risk factor related to post-SEMS insertion fever, SIRS, and bacteremia. Conclusion. The use of PA in patients with malignant colorectal obstruction may be not effective to prevent the development of infectious complications after SEMS insertion.

  1. Insertional inactivation of a chromosomal locus that modulates expression of potential virulence determinants in Staphylococcus aureus.

    Science.gov (United States)

    Cheung, A L; Wolz, C; Yeaman, M R; Bayer, A S

    1995-06-01

    A single insertion of transposon Tn551 into a unique chromosomal locus of Staphylococcus aureus ISP479C has resulted in a pleiotropic effect on the expression of both extracellular and cell wall proteins. In particular, the expression of cell wall protein A and clumping activity with fibrinogen were rendered undetectable in the mutant 1E3 compared with the parent. The secretion of alpha-hemolysin in mutant 1E3 was modestly increased. Southern blot and phenotypic analyses indicated that this locus is distinct from agr, xpr, and sar, three previously described global regulatory loci. Transduction experiments demonstrated that the genotype associated with mutant 1E3 could be transferred back into the parental strain ISP479C. The transductant 1E3-2 displayed a phenotypic profile similar to that of the original mutant. Northern (RNA) blot studies showed that this locus may be involved in modulating target genes at the mRNA level. In the rabbit endocarditis model, there was a significant decrease in both the infectivity rate and intravegetation bacterial density with mutant 1E3 compared with the parent at an inoculum of 10(3) CFU. Since protein A and the fibrinogen-binding protein(s) are major surface proteins that may mediate bacterial adhesion to host tissues, this locus may be an important genetic element involved in the expression of virulence determinants in S. aureus.

  2. Insert Design and Manufacturing for Foam-Core Composite Sandwich Structures

    Science.gov (United States)

    Lares, Alan

    Sandwich structures have been used in the aerospace industry for many years. The high strength to weight ratios that are possible with sandwich constructions makes them desirable for airframe applications. While sandwich structures are effective at handling distributed loads such as aerodynamic forces, they are prone to damage from concentrated loads at joints or due to impact. This is due to the relatively thin face-sheets and soft core materials typically found in sandwich structures. Carleton University's Uninhabited Aerial Vehicle (UAV) Project Team has designed and manufactured a UAV (GeoSury II Prototype) which features an all composite sandwich structure fuselage structure. The purpose of the aircraft is to conduct geomagnetic surveys. The GeoSury II Prototype serves as the test bed for many areas of research in advancing UAV technologies. Those areas of research include: low cost composite materials manufacturing, geomagnetic data acquisition, obstacle detection, autonomous operations and magnetic signature control. In this thesis work a methodology for designing and manufacturing inserts for foam-core sandwich structures was developed. The results of this research work enables a designer wishing to design a foam-core sandwich airframe structure, a means of quickly manufacturing optimized inserts for the safe introduction of discrete loads into the airframe. The previous GeoSury II Prototype insert designs (v.1 & v.2) were performance tested to establish a benchmark with which to compare future insert designs. Several designs and materials were considered for the new v.3 inserts. A plug and sleeve design was selected, due to its ability to effectively transfer the required loads to the sandwich structure. The insert material was chosen to be epoxy, reinforced with chopped carbon fibre. This material was chosen for its combination of strength, low mass and also compatibility with the face-sheet material. The v.3 insert assembly is 60% lighter than the

  3. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  4. Wavelength influence on nitrogen insertion into titanium by nanosecond pulsed laser irradiation in air

    Energy Technology Data Exchange (ETDEWEB)

    Torrent, F.; Lavisse, L. [Laboratoire Interdisciplinaire Carnot de Bourgogne (ICB), UMR 6303 CNRS-Université de Bourgogne, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France); Berger, P. [CEA/DSM/IRAMIS/SIS2M, CEA-Saclay, F-91191 Gif sur Yvette (France); SIS2M, UMR CEA-CNRS 3299, CEA-Saclay, F-91191 Gif sur Yvette (France); Jouvard, J.-M.; Andrzejewski, H.; Pillon, G.; Bourgeois, S.; Marco de Lucas, M.C. [Laboratoire Interdisciplinaire Carnot de Bourgogne (ICB), UMR 6303 CNRS-Université de Bourgogne, 9 Av. A. Savary, BP 47 870, F-21078 Dijon Cedex (France)

    2013-08-01

    We studied in this work the influence of the wavelength (532 vs. 1064 nm) on the insertion of nitrogen in titanium targets by surface laser treatments in air. The laser pulses were of 5 ns and the irradiance was lower than 25 × 10{sup 12} W/m{sup 2}. Results obtained using a frequency-doubled Nd:YAG laser at 532 nm were compared with those previously reported for laser treatments at 1064 nm. Nuclear reaction analysis and micro-Raman spectroscopy were used for determining the composition and the structure of the surface layers, respectively. Results showed the lower efficiency of irradiation at 532 nm for nitrogen insertion, which is possible only above threshold conditions depending on both the laser irradiance and the number of cumulated impacts per point. This was explained as being due to a higher ablative effect in the visible range. The insertion of oxygen giving rise to the growth of titanium oxynitrides was also discussed.

  5. E2LEMI:Energy-Efficient Logic Encryption Using Multiplexer Insertion

    Directory of Open Access Journals (Sweden)

    Qutaiba Alasad

    2017-02-01

    Full Text Available Due to the outsourcing of chip manufacturing, countermeasures against Integrated Circuit (IC piracy, reverse engineering, IC overbuilding and hardware Trojans (HTs become a hot research topic. To protect an IC from these attacks, logic encryption techniques have been considered as a low-cost defense mechanism. In this paper, our proposal is to insert the multiplexer (MUX with two cases: (i we randomly insert MUXs equal to half of the output bit number (half MUX insertions; and (ii we insert MUXs equal to the number of output bits (full MUX insertions. Hamming distance is adopted as a security evaluation. We also measure the delay, power and area overheads with the proposed technique.

  6. Modeling insertional mutagenesis using gene length and expression in murine embryonic stem cells.

    Directory of Open Access Journals (Sweden)

    Alex S Nord

    2007-07-01

    Full Text Available High-throughput mutagenesis of the mammalian genome is a powerful means to facilitate analysis of gene function. Gene trapping in embryonic stem cells (ESCs is the most widely used form of insertional mutagenesis in mammals. However, the rules governing its efficiency are not fully understood, and the effects of vector design on the likelihood of gene-trapping events have not been tested on a genome-wide scale.In this study, we used public gene-trap data to model gene-trap likelihood. Using the association of gene length and gene expression with gene-trap likelihood, we constructed spline-based regression models that characterize which genes are susceptible and which genes are resistant to gene-trapping techniques. We report results for three classes of gene-trap vectors, showing that both length and expression are significant determinants of trap likelihood for all vectors. Using our models, we also quantitatively identified hotspots of gene-trap activity, which represent loci where the high likelihood of vector insertion is controlled by factors other than length and expression. These formalized statistical models describe a high proportion of the variance in the likelihood of a gene being trapped by expression-dependent vectors and a lower, but still significant, proportion of the variance for vectors that are predicted to be independent of endogenous gene expression.The findings of significant expression and length effects reported here further the understanding of the determinants of vector insertion. Results from this analysis can be applied to help identify other important determinants of this important biological phenomenon and could assist planning of large-scale mutagenesis efforts.

  7. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  8. Infectious Complications of Radiologically Inserted Hickman Catheters in Patients with Hematologic Disorders

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Overhagen, Hans van; Wielenga, Jenne; Marie, Siem de; Nouwen, Jan; Ridder, Marie A.J. de; Lameris, Johan S.

    1998-01-01

    Purpose: To assess the incidence of infections and its influence on the survival of radiologically inserted Hickman catheters (HCs) in patients with hematologic disorders and to determine factors associated with premature HC removal. Methods: Survival and complications of 175 HCs in 115 patients were studied retrospectively. To describe the data the Kaplan-Meier method and the log-rank test were used, using the date of HC removal due to HC-related infection as endpoint. A stratified Cox regression model was used to determine explanatory factors. Results: Seventy (40%) HCs were removed prematurely because of proven or probable HC-related infections. The incidence of infection leading to HC removal was 4.78 per 1000 catheter-days for proven HC infections. Univariate analysis revealed that acute myeloid leukemia, acute lymphocytic leukemia, or treatment for these diseases, gender, each subsequent catheter in the same patient and insertion site increased the risk of premature removal of the catheter due to infection. Conclusion: Infection is a major problem in patients with HCs. Unfortunately, the factors associated with increased infection rates that were found in this study cannot be influenced. Further studies are necessary to determine the role of environmental conditions in a radiology suite in relation to the risk of developing a catheter-related infection

  9. Transcriptional Enhancers Induce Insertional Gene Deregulation Independently From the Vector Type and Design

    Science.gov (United States)

    Maruggi, Giulietta; Porcellini, Simona; Facchini, Giulia; Perna, Serena K; Cattoglio, Claudia; Sartori, Daniela; Ambrosi, Alessandro; Schambach, Axel; Baum, Christopher; Bonini, Chiara; Bovolenta, Chiara; Mavilio, Fulvio; Recchia, Alessandra

    2009-01-01

    The integration characteristics of retroviral (RV) vectors increase the probability of interfering with the regulation of cellular genes, and account for a tangible risk of insertional mutagenesis in treated patients. To assess the potential genotoxic risk of conventional or self-inactivating (SIN) γ-RV and lentiviral (LV) vectors independently from the biological consequences of the insertion event, we developed a quantitative assay based on real-time reverse transcriptase—PCR on low-density arrays to evaluate alterations of gene expression in individual primary T-cell clones. We show that the Moloney leukemia virus long terminal repeat (LTR) enhancer has the strongest activity in both a γ-RV and a LV vector context, while an internal cellular promoter induces deregulation of gene expression less frequently, at a shorter range and to a lower extent in both vector types. Downregulation of gene expression was observed only in the context of LV vectors. This study indicates that insertional gene activation is determined by the characteristics of the transcriptional regulatory elements carried by the vector, and is largely independent from the vector type or design. PMID:19293778

  10. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  11. Additive Manufacturing for Highly Efficient Window Inserts CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [ORNL; Chesser, Phillip C. [ORNL; Love, Lonnie J. [ORNL

    2018-04-01

    ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were explored as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.

  12. Insertional inactivation of a chromosomal locus that modulates expression of potential virulence determinants in Staphylococcus aureus.

    OpenAIRE

    Cheung, A L; Wolz, C; Yeaman, M R; Bayer, A S

    1995-01-01

    A single insertion of transposon Tn551 into a unique chromosomal locus of Staphylococcus aureus ISP479C has resulted in a pleiotropic effect on the expression of both extracellular and cell wall proteins. In particular, the expression of cell wall protein A and clumping activity with fibrinogen were rendered undetectable in the mutant 1E3 compared with the parent. The secretion of alpha-hemolysin in mutant 1E3 was modestly increased. Southern blot and phenotypic analyses indicated that this l...

  13. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  14. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    International Nuclear Information System (INIS)

    Woodley-Cook, Joel; Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E.

    2016-01-01

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  15. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    Energy Technology Data Exchange (ETDEWEB)

    Woodley-Cook, Joel, E-mail: jwoodleycook@gmail.com [The Scarborough Hospital, Vascular and Interventional Radiology, Department of Diagnostic Imaging (Canada); Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E. [University of Toronto, Vascular and Interventional Radiology, Department of Medical Imaging, University Health Network (Canada)

    2016-11-15

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  16. The Effect of Suture Anchor Insertion Angle on Calcaneus Pullout Strength: Challenging the Deadman's Angle.

    Science.gov (United States)

    Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K

    2017-10-01

    Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.

  17. Fluoroscopy-guided insertion of nasojejunal tubes in children - setting local diagnostic reference levels

    International Nuclear Information System (INIS)

    Vitta, Lavanya; Raghavan, Ashok; Sprigg, Alan; Morrell, Rachel

    2009-01-01

    Little is known about the radiation burden from fluoroscopy-guided insertions of nasojejunal tubes (NJTs) in children. There are no recommended or published standards of diagnostic reference levels (DRLs) available. To establish reference dose area product (DAP) levels for the fluoroscopy-guided insertion of nasojejunal tubes as a basis for setting DRLs for children. In addition, we wanted to assess our local practice and determine the success and complication rates associated with this procedure. Children who had NJT insertion procedures were identified retrospectively from the fluoroscopy database. The age of the child at the time of the procedure, DAP, screening time, outcome of the procedure, and any complications were recorded for each procedure. As the radiation dose depends on the size of the child, the children were assigned to three different age groups. The sample size, mean, median and third-quartile DAPs were calculated for each group. The third-quartile values were used to establish the DRLs. Of 186 procedures performed, 172 were successful on the first attempt. These were performed in a total of 43 children with 60% having multiple insertions over time. The third-quartile DAPs were as follows for each age group: 0-12 months, 2.6 cGy cm 2 ; 1-7 years, 2.45 cGy cm 2 ; >8 years, 14.6 cGy cm 2 . High DAP readings were obtained in the 0-12 months (n = 4) and >8 years (n = 2) age groups. No immediate complications were recorded. Fluoroscopy-guided insertion of NJTs is a highly successful procedure in a selected population of children and is associated with a low complication rate. The radiation dose per procedure is relatively low. (orig.)

  18. Typing Method for the QUB11a Locus of Mycobacterium tuberculosis: IS6110 Insertions and Tandem Repeat Analysis

    Directory of Open Access Journals (Sweden)

    Eriko Maeda-Mitani

    2016-01-01

    Full Text Available QUB11a is used as a locus for variable number of tandem repeats (VNTR analysis of Mycobacterium tuberculosis Beijing lineage. However, amplification of QUB11a occasionally produces large fragments (>1,400 bp that are not easily measured by capillary electrophoresis because of a lack of the typical stutter peak patterns that are used for counting repeat numbers. IS6110 insertion may complicate VNTR analysis of large QUB11a fragments in M. tuberculosis. We established a method for determining both tandem repeat numbers and IS6110 insertion in the QUB11a locus of M. tuberculosis using capillary electrophoresis analysis and BsmBI digestion. All 29 large QUB11a fragments (>1,200 bp investigated contained IS6110 insertions and varied in the number of repeats (18 patterns and location of IS6110 insertions. This method allows VNTR analysis with high discrimination.

  19. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  20. Lithium Insertion in LixMn2O4, 0

    DEFF Research Database (Denmark)

    West, Keld; Zachau-Christiansen, Birgit; Skaarup, Steen

    1996-01-01

    The electrochemical lithium insertion properties of highly crystalline LixMn2O4 are investigated in the approximate lithium insertion range 0 ... of the lithium insertion/extraction reactions is better at the higher voltages (versus Li/Li+), and particularly at the 4 V plateau. The lithium insertion/extraction reaction at the 1 V plateau although essentially reversible is associated with a significant voltage hysteresis....

  1. Short-term changes in chewing efficiency and subjective evaluation in normal dentate subjects after insertion of oral appliances with an occlusal flat table.

    Science.gov (United States)

    Satokawa, Y; Minami, I; Wakabayashi, N

    2018-02-01

    Oral appliances with an occlusal flat table are used as treatment dentures. However, the short-term effect of insertion of such oral appliances on chewing has not been reported. This study aimed to determine whether experimental and continuous insertion of oral appliances with an occlusal flat table has an effect on chewing efficiency and Oral Health Impact Profile (OHIP) in healthy participants. Ten participants each in the oral-appliance and control (no oral-appliance insertion) groups attended six data collection sessions for 5 consecutive days. Participants answered the OHIP questionnaire and underwent the chewing efficiency test. For each parameter, intergroup differences were investigated in terms of change from baseline to immediately after oral-appliance insertion (0 hour; P appliance insertion (P appliance insertion (P = .477 and .275, respectively). Differences between the two groups in the degree of change in other parameters were not significant. Insertion of oral appliances caused a decrease in chewing efficiency and an increase in OHIP scores. Continuous insertion improved functional limitation and physical pain within 96 hours. © 2017 John Wiley & Sons Ltd.

  2. The study on diamond-coated insert by DC plasma jet CVD

    International Nuclear Information System (INIS)

    Zhou Kesong; Dai Mingjiang; Song Jinbing; Kuang Tongchun; Liu Zhengyi

    2001-01-01

    Diamond coating were deposited on cemented carbide inserts by DC plasma jet CVD. The cemented carbide inserts were pretreated by methods including chemical etching of Co, Ar/H 2 plasma etching. The characteristics of diamond film, interface structure, adhesion strength and film stress were analysized by different methods such as SEM, XRD, Raman spectrum etc. A comparing experiment of cutting Al - 22 % Si alloy was carried out with diamond-coated cemented carbide inserts and uncoated cemented carbide inserts. The results show that the diamond-coated cemented carbide insert has a great advantage for cutting abrasive high content Al - Si alloy. (author)

  3. Timing of Etonogestrel Implant Insertion After Dilation and Evacuation: A Randomized Controlled Trial.

    Science.gov (United States)

    Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam

    2018-05-01

    To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.

  4. Analysis of generic insertions made of two symmetric triplets

    CERN Document Server

    D'Amico, T E

    1998-01-01

    This paper reports on the study undertaken to explore the capabilities of a symmetric triplet to achieve the optics constraints required by the inner triplet of an insertion and more generally of a co mplete insertion made of two symmetric triplets to match a double focus to a FODO lattice. It is based on analytical treatment formulating a number of constraints equal to the parameters available. Th is thorough and systematic analysis made it possible to establish for an inner triplet as well as for a complete insertion the existence of solutions and to explicitly find out all the solutions, with out resorting to unguided numerical searches. As a by-product, a lattice transformer, made of a single triplet, that matches two different FODO cells has been singled out and studied in details. The r esults should be profitable in a number of cases. Here, the method is applied to an insertion of the type of an experimental LHC insertion in order to investigate its domain of validity and tunability .

  5. Sorting genomes by reciprocal translocations, insertions, and deletions.

    Science.gov (United States)

    Qi, Xingqin; Li, Guojun; Li, Shuguang; Xu, Ying

    2010-01-01

    The problem of sorting by reciprocal translocations (abbreviated as SBT) arises from the field of comparative genomics, which is to find a shortest sequence of reciprocal translocations that transforms one genome Pi into another genome Gamma, with the restriction that Pi and Gamma contain the same genes. SBT has been proved to be polynomial-time solvable, and several polynomial algorithms have been developed. In this paper, we show how to extend Bergeron's SBT algorithm to include insertions and deletions, allowing to compare genomes containing different genes. In particular, if the gene set of Pi is a subset (or superset, respectively) of the gene set of Gamma, we present an approximation algorithm for transforming Pi into Gamma by reciprocal translocations and deletions (insertions, respectively), providing a sorting sequence with length at most OPT + 2, where OPT is the minimum number of translocations and deletions (insertions, respectively) needed to transform Pi into Gamma; if Pi and Gamma have different genes but not containing each other, we give a heuristic to transform Pi into Gamma by a shortest sequence of reciprocal translocations, insertions, and deletions, with bounds for the length of the sorting sequence it outputs. At a conceptual level, there is some similarity between our algorithm and the algorithm developed by El Mabrouk which is used to sort two chromosomes with different gene contents by reversals, insertions, and deletions.

  6. Installation of the LHC experimental insertions

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the low-beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  7. INSTALLATION OF THE LHC EXPERIMENTAL INSERTIONS

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the Low-Beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  8. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  9. Effects of porous insert on flame dynamics in a lean premixed swirl-stabilized combustor

    Science.gov (United States)

    Brown, Marcus; Agrawal, Ajay; Allen, James; Kornegay, John

    2016-11-01

    In this study, we investigated different methods of determining the effect a porous insert has on flame dynamics during lean premixed combustion. A metallic porous insert is used to mitigate instabilities in a swirl-stabilized combustor. Thermoacoustic instabilities are seen as negative consequences of lean premixed combustion and eliminating them is the motivation for our research. Three different diagnostics techniques with high-speed Photron SA5 cameras were used to monitor flame characteristics. Particle image velocimetry (PIV) was used to observe vortical structures and recirculation zones within the combustor. Using planar laser induced fluorescence (PLIF), we were able to observe changes in the reaction zones during instabilities. Finally, utilizing a color high-speed camera, visual images depicting a flame's oscillations during the instability were captured. Using these monitoring techniques, we are able to support the claims made in previous studies stating that the porous insert in the combustor significantly reduces the thermoacoustic instability. Funding for this research was provided by the NSF REU site Grant EEC 1358991 and NASA Grant NNX13AN14A.

  10. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  11. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  12. Test manufacturing of copper canisters with cast inserts. Assessment report

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, C.G

    1998-08-01

    The current design of canisters for the deep repository for spent nuclear fuel consists of an outer corrosion-protective copper casing in the form of a tubular section with lid and bottom and an inner pressure-resistant insert. The insert is designed to be manufactured by casting and inside are channels in which the fuel assemblies are to be placed. Over the last years, a number of full-scale manufacturing tests of all canister components have been carried out. The purpose has been to determine and develop the best manufacturing technique and to establish long-term contacts with the best suppliers of material and technology. Part of the work has involved the developing and implementing of a quality assurance system in accordance with ISO 9001, covering the whole chain from suppliers of material up to and including the delivery of assembled canisters. This report consists of a description of the design of the canister together with current drawings and complementary technical specifications stipulating, among other things, requirements placed on different materials. The different manufacturing methods that have been used are also described and commented on in both text and illustrations. For the manufacturing of copper tubes, the roll-forming of rolled plate to tube halves and longitudinal welding is a method that has been tested on a relatively large number of tubes by now, and that probably can be developed into a functioning production method. However, the very promising outcome of performed tests on seamless tube manufacturing, has resulted in a change in direction in tube manufacturing, focusing on continued testing of extrusion as well as pierce and draw processing in the immediate future. In connection with ongoing operations, new manufacturing tests of tubes with less material thickness will be carried out. Test manufacturing of cast inserts has resulted in the choice of nodular iron as material in the continued work. This improvement in design has resulted

  13. Test manufacturing of copper canisters with cast inserts. Assessment report

    International Nuclear Information System (INIS)

    Andersson, C.G.

    1998-08-01

    The current design of canisters for the deep repository for spent nuclear fuel consists of an outer corrosion-protective copper casing in the form of a tubular section with lid and bottom and an inner pressure-resistant insert. The insert is designed to be manufactured by casting and inside are channels in which the fuel assemblies are to be placed. Over the last years, a number of full-scale manufacturing tests of all canister components have been carried out. The purpose has been to determine and develop the best manufacturing technique and to establish long-term contacts with the best suppliers of material and technology. Part of the work has involved the developing and implementing of a quality assurance system in accordance with ISO 9001, covering the whole chain from suppliers of material up to and including the delivery of assembled canisters. This report consists of a description of the design of the canister together with current drawings and complementary technical specifications stipulating, among other things, requirements placed on different materials. The different manufacturing methods that have been used are also described and commented on in both text and illustrations. For the manufacturing of copper tubes, the roll-forming of rolled plate to tube halves and longitudinal welding is a method that has been tested on a relatively large number of tubes by now, and that probably can be developed into a functioning production method. However, the very promising outcome of performed tests on seamless tube manufacturing, has resulted in a change in direction in tube manufacturing, focusing on continued testing of extrusion as well as pierce and draw processing in the immediate future. In connection with ongoing operations, new manufacturing tests of tubes with less material thickness will be carried out. Test manufacturing of cast inserts has resulted in the choice of nodular iron as material in the continued work. This improvement in design has resulted

  14. Heads or tails: L1 insertion-associated 5' homopolymeric sequences

    Directory of Open Access Journals (Sweden)

    Meyer Thomas J

    2010-02-01

    Full Text Available Abstract Background L1s are one of the most successful autonomous mobile elements in primate genomes. These elements comprise as much as 17% of primate genomes with the majority of insertions occurring via target primed reverse transcription (TPRT. Twin priming, a variant of TPRT, can result in unusual DNA sequence architecture. These insertions appear to be inverted, truncated L1s flanked by target site duplications. Results We report on loci with sequence architecture consistent with variants of the twin priming mechanism and introduce dual priming, a mechanism that could generate similar sequence characteristics. These insertions take the form of truncated L1s with hallmarks of classical TPRT insertions but having a poly(T simple repeat at the 5' end of the insertion. We identified loci using computational analyses of the human, chimpanzee, orangutan, rhesus macaque and marmoset genomes. Insertion site characteristics for all putative loci were experimentally verified. Conclusions The 39 loci that passed our computational and experimental screens probably represent inversion-deletion events which resulted in a 5' inverted poly(A tail. Based on our observations of these loci and their local sequence properties, we conclude that they most probably represent twin priming events with unusually short non-inverted portions. We postulate that dual priming could, theoretically, produce the same patterns. The resulting homopolymeric stretches associated with these insertion events may promote genomic instability and create potential target sites for future retrotransposition events.

  15. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  16. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  17. Determining the effects of thermal conductivity on epoxy molds using profiled cooling channels with metal inserts

    International Nuclear Information System (INIS)

    Altaf, Khurram; Rani, Abdul Ahmad Majdi; Ahmad, Faiz; Baharom, Masri; Raghavan, Vijay R.

    2016-01-01

    Polymer injection molds are generally manufactured with metallic materials, such as tool steel, which provide reliable working of molds and extended service life. The manufacture of injection molds with steel is a prolonged process because of the strength of steel. For a short prototype production run, one of the suitable choices could be the use of aluminum-filled epoxy material, which can produce a functional mold in a short time as compared with a conventionally machined tool. Aluminum-filled epoxy tooling is a good choice for short production runs for engineering applications, yet works best for relatively simple shapes. The advantages in relation to the fabrication of injection molds with epoxy-based materials include time saving in producing the mold, epoxy curing at ambient temperature, and ease of machining and post processing. Nevertheless, one major drawback of epoxy material is its poor thermal conductivity, which results in a relatively longer cooling time for epoxy injection molds. This study investigates some of the innovative ideas for enhancing the thermal conductivity for epoxy molds. The basic concept behind these ideas was to embed a highly thermally conductive metal insert within the mold between cavities with an innovative design of cooling channels called profiled cooling channels. This technique will increase the effective thermal conductivity of the epoxy mold, leading to the reduction in cooling time for the injection molded polymer part. Experimental analysis conducted in the current study also verified that the mold with profiled cooling channels and embedded metal insert has significantly reduced the cooling time

  18. Determining the effects of thermal conductivity on epoxy molds using profiled cooling channels with metal inserts

    Energy Technology Data Exchange (ETDEWEB)

    Altaf, Khurram; Rani, Abdul Ahmad Majdi; Ahmad, Faiz; Baharom, Masri [Mechanical Engineering Dept., Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak (Malaysia); Raghavan, Vijay R. [OYL Manufacturing, Sungai Buloh (Malaysia)

    2016-11-15

    Polymer injection molds are generally manufactured with metallic materials, such as tool steel, which provide reliable working of molds and extended service life. The manufacture of injection molds with steel is a prolonged process because of the strength of steel. For a short prototype production run, one of the suitable choices could be the use of aluminum-filled epoxy material, which can produce a functional mold in a short time as compared with a conventionally machined tool. Aluminum-filled epoxy tooling is a good choice for short production runs for engineering applications, yet works best for relatively simple shapes. The advantages in relation to the fabrication of injection molds with epoxy-based materials include time saving in producing the mold, epoxy curing at ambient temperature, and ease of machining and post processing. Nevertheless, one major drawback of epoxy material is its poor thermal conductivity, which results in a relatively longer cooling time for epoxy injection molds. This study investigates some of the innovative ideas for enhancing the thermal conductivity for epoxy molds. The basic concept behind these ideas was to embed a highly thermally conductive metal insert within the mold between cavities with an innovative design of cooling channels called profiled cooling channels. This technique will increase the effective thermal conductivity of the epoxy mold, leading to the reduction in cooling time for the injection molded polymer part. Experimental analysis conducted in the current study also verified that the mold with profiled cooling channels and embedded metal insert has significantly reduced the cooling time.

  19. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  20. [Visual functions' detailed evaluating in patients with Sjögren's syndrome before and after intracanalicular implants' (Smart Plug) insertion--(first results)].

    Science.gov (United States)

    Hejcmanová, D; Nemcová, I; Slezák, R

    2006-05-01

    The aim of the study was to determine exact visual functions (log MAR [minimal angle of resolution] and CS [contrast sensitivity]) and to evaluate corneal topographic maps in patients with established (by means of laboratory and biopsy examinations) Sjogren's Syndrome, and to determine the difference in subjective symptoms before and after insertion of the intracanalicular implants as well. Twelve eyes (1 man, 6 women) with established Sjogren's syndrome were examined before and during two months after the insertion of the plugs. The best-corrected visual acuity (BCVA) was assessed on Landolt C rings optotypes. CS was measured on computer-controlled device (Neuroscientific Corp., U.S.A.) in 6 space-frequencies (0.74-29.55 c/deg). The corneal topographic changes (Keraton Opticon) were established by means of comparing total aberrations values before and after the intracanalicular implants' (Smart Plugs type) insertion. The control group for visual functions assessment consisted of 10 woman (20 eyes) of similar middle age. The BCVA on log MAR optotypes was 0.84 (0.69-0.95) before and 0.88 (0.52-1.23) after the insertion, on both occasions, it was lower than in the control group. The CS was before the insertion in all of the spatial frequencies lower, the largest differences were in the frequencies range 1.97-7.29 c/deg (p test, in 100% positive before the treatment, was after the insertion in 75% negative; the height of the tear-meniscus was positive in 100% before the procedure, and after that, its measurement improved to 1 mm in 91%; in 9% it was 1.5 mm. We also noticed changes of the ocular surface by means of lissamine green staining; this test was before the procedure positive in 100%, the improvement after that was in 63%. The regularity of the corneal surface is the determining factor of visual functions in "dry eyes". The measurement of the corneal topography is useful in differential diagnosis and helps to distinguish mild and more serious conditions of dry

  1. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  2. Remifentanil dose for laryngeal mask airway insertion with a single standard dose of propofol during emergency airway management in elderly patients.

    Science.gov (United States)

    Ryu, Junghee; Oh, Ah Young; Baek, Ji-Seok; Kim, Jin-Hee; Park, Sang-Heon; Noh, Jae-Mun

    2014-04-01

    This study determined the dose of remifentanil to use during insertion of a Classic™ laryngeal mask airway (LMA, The Laryngeal Mask Co., Nicosia, Cyprus) in elderly patients during emergency airway management when combined with a single dose of propofol. Patients aged 65-80 years were enrolled. Anesthesia was induced with propofol 1 mg/kg, and then a blinded dose of remifentanil was infused over 30 s after confirming the patient's loss of consciousness. The dose of remifentanil was determined using Dixon's up-and-down method, starting at 0.5 µg/kg (a step size of 0.1 µg/kg). Insertion of the LMA was attempted 60 s after loss of consciousness. In total, 23 patients were recruited and the mean age ± standard deviation was 72 ± 3 years. The effective dose for successful LMA insertion in 50% of the patients (ED50) was 0.20 ± 0.05 µg/kg. No patient needed more than 0.3 µg/kg. Remifentanil 0.20 ± 0.05 µg/kg with propofol 1 mg/kg resulted in excellent LMA insertion in 50% of elderly patients without significant hemodynamic changes during emergency airway management.

  3. Mammographic and Ultrasonographic Findings of the Chemoport Insertion Site

    International Nuclear Information System (INIS)

    Kim, Seun Jung; Kang, Bong Joo; Cha, Eun Suk; Park, Hye Jung; Kim, Sung Hun; Choi, Jae Jeong; Lee, Ji Hye

    2010-01-01

    To describe mammographic and ultrasonographic findings of previous chemoport insertion sites. We included patients who had abnormal findings at chemoport insertion sites on mammography and ultrasonography from 224 patients who underwent chemoport insertion and breast imaging at our institution between January, 2005, and December, 2007. Abnormal findings were identified in 16 mammographies and 14 ultrasonographies in 10 patients. The mean age was 50.9 years and the age range was from 44 to 67 years. Abnormal findings on mammography and ultrasonography were retrospectively analyzed according to ACR/BI-RADS. All cases were followed up with imaging studies for 2 years to confirm changes after chemoport insertion. Of the abnormal findings identified on mammography, focal asymmetry (7/16) was the most common. Other abnormal findings included mass (6/16), skin retraction (2/16), residual chemoport tip (1/16), and trabecular thickening (1/16). Of the abnormal findings seen on ultrasonography, skin thickening (12/14) was the most common. Other abnormal findings included mass (5/14), diffuse increased echogenicity of subcutaneous tissue (1/14), and a localized skin nodule (1/14). Abnormal findings on mammography and ultrasonography were located in the upper outer quadrant in 5 patients, upper inner quadrant in 3 patients, and mid upper portion in 1 patient. In 1 patient, the abnormal finding was only identified in the mediolateral oblique view of her mammography. Radiologists should be aware of potential abnormal findings on mammography and ultrasonography following chemoport insertion. In particular, ultrasonography is a very useful modality for detecting skin complications after chemoport insertion

  4. Acute changes associated with electrode insertion measured with optical coherence microscopy

    Science.gov (United States)

    Hammer, Daniel X.; Lozzi, Andrea; Boretsky, Adam; Agrawal, Anant; Welle, Cristin G.

    2016-03-01

    Despite advances in functional neural imaging, penetrating microelectrodes provide the most direct interface for the extraction of neural signals from the nervous system and are a critical component of many high degree-of-freedom braincomputer interface devices. Electrode insertion is a traumatic event that elicits a complex neuroinflammatory response. In this investigation we applied optical coherence microscopy (OCM), particularly optical coherence angiography (OCA), to characterize the immediate tissue response during microelectrode insertion. Microelectrodes of varying dimension and footprint (one-, two-, and four-shank) were inserted into mouse motor cortex beneath a window after craniotomy surgery. The microelectrodes were inserted in 3-4 steps at 15-20°, with approximately 250 μm linear insertion distance for each step. Before insertion and between each step, OCM datasets were collected, including for quantitative capillary velocimetry. A cohort of control animals without microelectrode insertion was also imaged over a similar time period (2-3 hours). Mechanical tissue deformation was observed in all the experimental animals. The quantitative angiography results varied across animals, and were not correlated with device dimensions. In some cases, localized flow drop-out was observed in a small region surrounding the electrode, while in other instances a global disruption in flow occurred, perhaps as a result of large vessel compression caused by mechanical pressure. OCM is a tool that can be used in various neurophotonics applications, including quantification of the neuroinflammatory response to penetrating electrode insertion.

  5. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

    Science.gov (United States)

    Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao

    2017-12-01

    The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.

  6. Controlled acrylate insertion regioselectivity in diazaphospholidine- sulfonato palladium(II) complexes

    KAUST Repository

    Wucher, Philipp

    2012-12-24

    Diazaphospholidine-sulfonato Pd(II) complexes [{κ2-P,O-(N- Ar2C2H4N2P)C6H 4SO3}PdMe(L)] 1-L (L = dmso, pyridine, lutidine, or μ-LiCl(solvent); 1a: Ar = Ph, 1b: Ar = 2-MeC6H4, 1c: Ar = 2-MeOC6H4, 1d: Ar = 2,4,6-Me3C 6H2, 1e: Ar = 2,6-iPr2C6H 3, 1f: Ar = 2,6-(p-tolyl)2C6H3) were prepared and structurally characterized. The regioselectivity of methyl acrylate (MA) insertion into the Pd-Me bond is entirely inverted from >93% 1,2-insertion for bulky substituents (1d-f, yielding the insertion products [(P̂O)Pd{κ2-C,O-CH2CHMeC(O)OMe], 12) to the usual electronically controlled 2,1-insertion (>95%) for the less bulky Ar = Ph (1a, yielding the insertion product [(P̂O)Pd{κ2-C,O- CHEtC(O)OMe], 11, and β-H elimination product methyl crotonate). DFT studies underline that this is due to a more favorable insertion transition state (2,1- favored by 12 kJ mol-1 over 1,2- for 1a) vs destabilization of the 2,1-insertion transition state in 1d,e. By contrast, MA insertion into the novel isolated and structurally characterized hydride and deuteride complexes [{κ2-P,O-(N-Ar2C 2H4N2P)C6H4SO 3}PdR(lutidine)] (Ar = 2,6-iPr2C6H3; 9e: R = H, 10e: R = D) occurs 2,1-selectively. This is due to the insertion occurring from the isomer with the P-donor and the olefin in trans arrangement, rather than the insertion into the alkyl from the cis isomer in which the olefin is in proximity to the bulky diazaphospholidine. 1a-f are precursors to active catalysts for ethylene polymerization to highly linear polyethylene with M n up to 35 000 g mol-1. In copolymerization experiments, norbornene was incorporated in up to 6.1 mol % into the polyethylene backbone. © 2012 American Chemical Society.

  7. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    Science.gov (United States)

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. In situ57Fe Moessbauer Investigation of Solid-State Redox Reactions of Lithium Insertion Electrodes for Advanced Batteries

    International Nuclear Information System (INIS)

    Sakai, Yoichi; Ariyoshi, Kingo; Ohzuku, Tsutomu

    2002-01-01

    A novel in situ electrochemical cell for 57 Fe Moessbauer measurements was developed in order to clarify the mechanisms of solid-state redox reactions in lithium insertion materials containing iron. Our in situ Moessbauer technique was successfully applied to the determination as to which transition metal ion was a redox center in the insertion electrodes, such as LiFe 0.5 Mn 1.5 O 4 , LiFeTiO 4 , or LiFe 0.25 Ni 0.75 O 2 , for the lithium-ion batteries.

  9. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  10. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  11. Compact insert design for cryogenic pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  12. Regulatory perspective on incomplete control rod insertions

    International Nuclear Information System (INIS)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff's understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required

  13. Extra-anatomical complications of antegrade double-J insertion

    Directory of Open Access Journals (Sweden)

    A R Rao

    2011-01-01

    Full Text Available Introduction: Insertion of a double-J (JJ stent is a common procedure often carried out in the retrograde route by the urologists and the antegrade route by the radiologists. Reported complications include stent migration, encrustation, and fracture. Extra-anatomic placement of an antegrade JJ stent is a rare but infrequently recognized complication. Materials and Methods: We performed a retrospective audit of 165 antegrade JJ stent insertions performed over three consecutive years by a single interventional radiologist. All renal units were hydronephrotic at the time of nephrostomy. All procedures were performed under local anaesthetic with antibiotic prophylaxis. Results: Antegrade stent insertion was carried out simultaneously at the time of nephrostomy in 55 of the 165 cases (33%. The remainder were inserted at a mean of 2 weeks following decompression. In five (3% patients, who had delayed antegrade stenting following nephrostomy, the procedure was complicated by silent ureteric perforation and an extra-anatomic placement of the stent. These complications had delayed manifestations, which included two retroperitoneal abscesses, a pelvic urinoma, a case each of ureterorectal fistula, and ureterovaginal fistula. Risk factors for ureteric perforation include previous pelvic malignancy, pelvic surgery, pelvic radiation, and a history of ureteric manipulation. Conclusion: Antegrade ureteric JJ stenting is a procedure not without complications. Extra-anatomic placement of the antegrade stent is a hitherto the infrequently reported complication but needs a high index of suspicion to be diagnosed. Risk factors for ureteric perforation at the time of stent insertion have to be considered to prevent this potential complication.

  14. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  15. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  16. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  17. Facile construction of a random protein domain insertion library using an engineered transposon.

    Science.gov (United States)

    Shah, Vandan; Pierre, Brennal; Kim, Jin Ryoun

    2013-01-15

    Insertional fusion between multiple protein domains represents a novel means of creating integrated functionalities. Currently, there is no robust guideline for selection of insertion sites ensuring the desired functional outcome of insertional fusion. Therefore, construction and testing of random domain insertion libraries, in which a host protein domain is randomly inserted into a guest protein domain, significantly benefit extensive exploration of sequence spaces for insertion sites. Short peptide residues are usually introduced between protein domains to alleviate structural conflicts, and the interdomain linker residues may affect the functional outcome of protein insertion complexes. Unfortunately, optimal control of interdomain linker residues is not always available in conventional methods used to construct random domain insertion libraries. Moreover, most conventional methods employ blunt-end rather than sticky-end ligation between host and guest DNA fragments, thus lowering library construction efficiency. Here, we report the facile construction of random domain insertion libraries using an engineered transposon. We show that random domain insertion with optimal control of interdomain linker residues was possible with our engineered transposon-based method. In addition, our method employs sticky-end rather than blunt-end ligation between host and guest DNA fragments, thus allowing for facile construction of relatively large sized libraries. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Verification of the numerical model of insert-type joint of scaffolding in relation to experimental research

    Science.gov (United States)

    Pieńko, Michał; Błazik-Borowa, Ewa

    2018-01-01

    This paper presents the problem of comparing the results of computer simulations with the results of laboratory tests. The subject of the study was the insert-type joint of scaffolding loaded with a bending moment. The research was carried out on the real elements of the scaffolding. Due to the complexity of the connection different friction coefficients and depths of wedge insertion were taken into account in the analysis. The aim of conducting the series of analyses was to determine the sensitivity of the model to the mentioned characteristics. Since laboratory tests were carried out on the real samples, there were no preparations of surface involved in the load transfer. This approach caused many problems with the clear definition of the nature of work of individual node elements during the load. The analysis consist of two stages: the stage in which the connection is defined (the wedge is inserted into the rosette), and the loading stage (the node is loaded by the bending moment).

  19. SV40 host-substituted variants: a new look at the monkey DNA inserts and recombinant junctions.

    Science.gov (United States)

    Singer, Maxine; Winocour, Ernest

    2011-04-10

    The available monkey genomic data banks were examined in order to determine the chromosomal locations of the host DNA inserts in 8 host-substituted SV40 variant DNAs. Five of the 8 variants contained more than one linked monkey DNA insert per tandem repeat unit and in all cases but one, the 19 monkey DNA inserts in the 8 variants mapped to different locations in the monkey genome. The 50 parental DNAs (32 monkey and 18 SV40 DNA segments) which spanned the crossover and flanking regions that participated in monkey/monkey and monkey/SV40 recombinations were characterized by substantial levels of microhomology of up to 8 nucleotides in length; the parental DNAs also exhibited direct and inverted repeats at or adjacent to the crossover sequences. We discuss how the host-substituted SV40 variants arose and the nature of the recombination mechanisms involved. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Symplectic models for general insertion devices

    International Nuclear Information System (INIS)

    Wu, Y.; Forest, E.; Robin, D. S.; Nishimura, H.; Wolski, A.; Litvinenko, V. N.

    2001-01-01

    A variety of insertion devices (IDs), wigglers and undulators, linearly or elliptically polarized,are widely used as high brightness radiation sources at the modern light source rings. Long and high-field wigglers have also been proposed as the main source of radiation damping at next generation damping rings. As a result, it becomes increasingly important to understand the impact of IDs on the charged particle dynamics in the storage ring. In this paper, we report our recent development of a general explicit symplectic model for IDs with the paraxial ray approximation. High-order explicit symplectic integrators are developed to study real-world insertion devices with a number of wiggler harmonics and arbitrary polarizations

  1. RERTR-12 Insertion 1 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Lillo, M.A.; Chang, G.S.; Woolstenhulme, N.E.; Roth, G.A.; Wachs, D.M.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications. RERTR-12 insertion 1 includes the capsules irradiated during the first two irradiation cycles. These capsules include Z, X1, X2 and X3 capsules. The following report summarizes the life of the RERTR-12 insertion 1 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  2. RERTR-12 Insertion 2 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Chang, G.S.; Wachs, D.M.; Roth, G.A.; Woolstenhulme, N.E.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  3. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    An ISABELLE workshop of the summer 1976 series, which was held at Brookhaven August 16--20, focused on the design and utilization of the experimental insertions. The goals of the workshop are outlined, and a few general remarks about the results are presented

  4. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  5. Spontaneous insertion of GPI anchors into cholesterol-rich membrane domains

    Directory of Open Access Journals (Sweden)

    Jing Li

    2018-05-01

    Full Text Available GPI-Anchored proteins (GPI-APs can be exogenously transferred onto bilayer membranes both in vivo and in vitro, while the mechanism by which this transfer process occurs is unknown. In this work, we used atomistic molecular dynamics simulations and free energy calculations to characterize the essential influence of cholesterol on insertion of the GPI anchors into plasma membranes. We demonstrate, both dynamically and energetically, that in the presence of cholesterol, the tails of GPI anchors are able to penetrate inside the core of the lipid membrane spontaneously with a three-step mechanism, while in the absence of cholesterol no spontaneous insertion was observed. We ascribe the failure of insertion to the strong thermal fluctuation of lipid molecules in cholesterol-free bilayer, which generates a repulsive force in entropic origin. In the presence of cholesterol, however, the fluctuation of lipids is strongly reduced, thus decreasing the barrier for the anchor insertion. Based on this observation, we propose a hypothesis that addition of cholesterol creates vertical creases in membranes for the insertion of acyl chains. Moreover, we find that the GPI anchor could also spontaneously inserted into the boundary between cholesterol-rich and cholesterol-depleted domains. Our results shed light on the mechanism of cholesterol-mediated interaction between membrane proteins with acyl chain and plasma membranes in living cells.

  6. Spontaneous insertion of GPI anchors into cholesterol-rich membrane domains

    Science.gov (United States)

    Li, Jing; Liu, Xiuhua; Tian, Falin; Yue, Tongtao; Zhang, Xianren; Cao, Dapeng

    2018-05-01

    GPI-Anchored proteins (GPI-APs) can be exogenously transferred onto bilayer membranes both in vivo and in vitro, while the mechanism by which this transfer process occurs is unknown. In this work, we used atomistic molecular dynamics simulations and free energy calculations to characterize the essential influence of cholesterol on insertion of the GPI anchors into plasma membranes. We demonstrate, both dynamically and energetically, that in the presence of cholesterol, the tails of GPI anchors are able to penetrate inside the core of the lipid membrane spontaneously with a three-step mechanism, while in the absence of cholesterol no spontaneous insertion was observed. We ascribe the failure of insertion to the strong thermal fluctuation of lipid molecules in cholesterol-free bilayer, which generates a repulsive force in entropic origin. In the presence of cholesterol, however, the fluctuation of lipids is strongly reduced, thus decreasing the barrier for the anchor insertion. Based on this observation, we propose a hypothesis that addition of cholesterol creates vertical creases in membranes for the insertion of acyl chains. Moreover, we find that the GPI anchor could also spontaneously inserted into the boundary between cholesterol-rich and cholesterol-depleted domains. Our results shed light on the mechanism of cholesterol-mediated interaction between membrane proteins with acyl chain and plasma membranes in living cells.

  7. Ex vivo rabbit cornea diffusion studies with a soluble insert of moxifloxacin.

    Science.gov (United States)

    Sebastián-Morelló, María; Calatayud-Pascual, María Aracely; Rodilla, Vicent; Balaguer-Fernández, Cristina; López-Castellano, Alicia

    2018-02-01

    The objective of this research was to develop and evaluate an ocular insert for the controlled drug delivery of moxifloxacin which could perhaps be used in the treatment of corneal keratitis or even bacterial endophthalmitis. We have evaluated the ex vivo ocular diffusion of moxifloxacin through rabbit cornea, both fresh and preserved under different conditions. Histological studies were also carried out. Subsequently, drug matrix inserts were prepared using bioadhesive polymers. The inserts were evaluated for their physicochemical parameters. Ophthalmic ex vivo permeation of moxifloxacin was carried out with the most promising insert. The formulate insert was thin and provided higher ocular diffusion than commercial formulations. Ocular diffusion studies revealed significant differences between fresh and frozen corneas. Histological examinations also showed differences in the thickness of stroma between fresh and frozen corneas. The ophthalmic insert we have developed allows a larger quantity of moxifloxacin to permeate through the cornea than existing commercial formulations of the drug. Ocular delivery of moxifloxacin with this insert could be a new approach for the treatment of eye diseases.

  8. Metallographic study of reconstitution welding in inserts of 1 cm3

    International Nuclear Information System (INIS)

    Romero C, J.; Garcia R, R.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.

    2007-01-01

    In this article, the welding metallographic study carried out in Charpy test tubes reconstituted with notch in 'V', used in the surveillance programs of the vessel in nucleo electric plants is described. Inserts of 1 cm 3 are used, where the inserts are usually rectangular of minimum 18 millimeters of length. The importance of using inserts of 1 cm 3 is that the mechanical properties can be measured in another direction of the vessel steel, when changing the direction or sense of the notch in 'V' or the face where this notch is made in the insert. (Author)

  9. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  10. Second harmonic sound field after insertion of a biological tissue sample

    Science.gov (United States)

    Zhang, Dong; Gong, Xiu-Fen; Zhang, Bo

    2002-01-01

    Second harmonic sound field after inserting a biological tissue sample is investigated by theory and experiment. The sample is inserted perpendicular to the sound axis, whose acoustical properties are different from those of surrounding medium (distilled water). By using the superposition of Gaussian beams and the KZK equation in quasilinear and parabolic approximations, the second harmonic field after insertion of the sample can be derived analytically and expressed as a linear combination of self- and cross-interaction of the Gaussian beams. Egg white, egg yolk, porcine liver, and porcine fat are used as the samples and inserted in the sound field radiated from a 2 MHz uniformly excited focusing source. Axial normalized sound pressure curves of the second harmonic wave before and after inserting the sample are measured and compared with the theoretical results calculated with 10 items of Gaussian beam functions.

  11. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    International Nuclear Information System (INIS)

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  12. Effect of insertion torque on titanium implant osseointegration: an animal experimental study.

    Science.gov (United States)

    Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen

    2015-02-01

    To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P torque led to an increased BA/TA after 4 week of healing (P torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  14. Live insertion method used for main renewal

    International Nuclear Information System (INIS)

    Solkowitz, M.

    1992-01-01

    Baltimore Gas and Electric's pilot project using the live insertion method to replace a cast iron main provided excellent results. Its use on Eastern Avenue, a major state highway, was cost effective, provided gas service to customers during the work, required relatively short construction time and resulted in only minor traffic disruptions. Gas service transfers to the new main were done at customer convenience and resulted in outages of only a few hours per customer. This paper reports that the project involved inserting a 6-in. plastic line inside an existing 10-in. cast iron main. Miller Pipeline Corp., Indianapolis, supplier of the Insertec left-angle R right-angle live insertion method was contracted for the job. Miller technicians assisted BG and E forces by providing a load analysis of the main, a pushing machine and related supplies, foaming equipment and pipe cutting tools. Company forces were responsible for all preparatory work, including opening all excavations, installing bypasses, and fusing and testing the plastic pipe. Service transfers and renewals were also completed by company employees

  15. Efficient DNA fingerprinting based on the targeted sequencing of active retrotransposon insertion sites using a bench-top high-throughput sequencing platform.

    Science.gov (United States)

    Monden, Yuki; Yamamoto, Ayaka; Shindo, Akiko; Tahara, Makoto

    2014-10-01

    In many crop species, DNA fingerprinting is required for the precise identification of cultivars to protect the rights of breeders. Many families of retrotransposons have multiple copies throughout the eukaryotic genome and their integrated copies are inherited genetically. Thus, their insertion polymorphisms among cultivars are useful for DNA fingerprinting. In this study, we conducted a DNA fingerprinting based on the insertion polymorphisms of active retrotransposon families (Rtsp-1 and LIb) in sweet potato. Using 38 cultivars, we identified 2,024 insertion sites in the two families with an Illumina MiSeq sequencing platform. Of these insertion sites, 91.4% appeared to be polymorphic among the cultivars and 376 cultivar-specific insertion sites were identified, which were converted directly into cultivar-specific sequence-characterized amplified region (SCAR) markers. A phylogenetic tree was constructed using these insertion sites, which corresponded well with known pedigree information, thereby indicating their suitability for genetic diversity studies. Thus, the genome-wide comparative analysis of active retrotransposon insertion sites using the bench-top MiSeq sequencing platform is highly effective for DNA fingerprinting without any requirement for whole genome sequence information. This approach may facilitate the development of practical polymerase chain reaction-based cultivar diagnostic system and could also be applied to the determination of genetic relationships. © The Author 2014. Published by Oxford University Press on behalf of Kazusa DNA Research Institute.

  16. Dynamic insertion analysis of control rods of BWR under seismic excitation

    International Nuclear Information System (INIS)

    Nakagawa, Masaki; Koide, Yuichi; Fukushi, Naoki; Ishigaki, Hirokuni; Okumura, Kazue

    2007-01-01

    The dynamic insertion characteristics of the control rods for the boiling water reactors under the seismic excitation are investigated using non-linear analytical models. The control rod insertion capability is one of the most important items for the safety of nuclear power plants under the seismic events. Predicting the control rod insertion behavior during the earthquake is important in the course of the control rod seismic design. We developed the analytical models using the finite element method (FEM). The effect of the interaction force between the control rod and the fuel assemblies is considered in the non-linear analysis. This interaction force courses the resistance force to the control rod during its insertion behavior. The validity of analytical methods was confirmed by comparing the analytical results with the experimental ones. Using the analytical models, the effects of input seismic motion and structural parameters of the control rods and the fuel assemblies, such as the thickness of the channel box, on the insertion time are investigated. These analytical methods can predict insertion time of the control rod, and are useful for the seismic design of the control rod assemblies. (author)

  17. Evolution-based Virtual Content Insertion with Visually Virtual Interactions in Videos

    Science.gov (United States)

    Chang, Chia-Hu; Wu, Ja-Ling

    With the development of content-based multimedia analysis, virtual content insertion has been widely used and studied for video enrichment and multimedia advertising. However, how to automatically insert a user-selected virtual content into personal videos in a less-intrusive manner, with an attractive representation, is a challenging problem. In this chapter, we present an evolution-based virtual content insertion system which can insert virtual contents into videos with evolved animations according to predefined behaviors emulating the characteristics of evolutionary biology. The videos are considered not only as carriers of message conveyed by the virtual content but also as the environment in which the lifelike virtual contents live. Thus, the inserted virtual content will be affected by the videos to trigger a series of artificial evolutions and evolve its appearances and behaviors while interacting with video contents. By inserting virtual contents into videos through the system, users can easily create entertaining storylines and turn their personal videos into visually appealing ones. In addition, it would bring a new opportunity to increase the advertising revenue for video assets of the media industry and online video-sharing websites.

  18. Development and comparison of projection and image space 3D nodule insertion techniques

    Science.gov (United States)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan

    2016-04-01

    This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.

  19. Characterisation of protein stability in rod-insert vaginal rings.

    Science.gov (United States)

    Pattani, Aditya; Lowry, Deborah; Curran, Rhonda M; McGrath, Stephanie; Kett, Vicky L; Andrews, Gavin P; Malcolm, R Karl

    2012-07-01

    A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4 °C, but not when stored at 40 °C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40 °C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40 °C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general. Copyright

  20. Characterization of GM events by insert knowledge adapted re-sequencing approaches

    OpenAIRE

    Yang, Litao; Wang, Congmao; Holst-Jensen, Arne; Morisset, Dany; Lin, Yongjun; Zhang, Dabing

    2013-01-01

    Detection methods and data from molecular characterization of genetically modified (GM) events are needed by stakeholders of public risk assessors and regulators. Generally, the molecular characteristics of GM events are incomprehensively revealed by current approaches and biased towards detecting transformation vector derived sequences. GM events are classified based on available knowledge of the sequences of vectors and inserts (insert knowledge). Herein we present three insert knowledge-ad...

  1. Insertion and crossing region design

    International Nuclear Information System (INIS)

    Wienands, U.; Beloshitsky, P.

    2001-01-01

    This article is the summary of the 5-afternoon tutorial on insertions for circular machines. Roughly half the course (Part 1) was spent discussing interaction regions, We start by recapitulating basic beam optics including building blocks. This provides the tools to analyze the basic structure of interaction regions and explore the parameter space. This simple example is then successively refined and made more realistic. Examples of realized interaction regions for both hadron and electron machines are shown and their salient features and differences explained. A brief discussion of solenoid-decoupling brings Part 1 to a close. In Part 2 we discussed various utility sections. Dispersion suppressors are presented in detail discussing the principles as well as the practical implementation of flexible suppressors using LEP as an example. Injection schemes, both single-turn and multi-turn stacking, are presented in depth. The matching of wiggler and undulator insertions and a discussion of the impact of these devices on beam parameters closes out Part 2

  2. Sequence and structural analysis of the chitinase insertion domain reveals two conserved motifs involved in chitin-binding.

    Directory of Open Access Journals (Sweden)

    Hai Li

    2010-01-01

    Full Text Available Chitinases are prevalent in life and are found in species including archaea, bacteria, fungi, plants, and animals. They break down chitin, which is the second most abundant carbohydrate in nature after cellulose. Hence, they are important for maintaining a balance between carbon and nitrogen trapped as insoluble chitin in biomass. Chitinases are classified into two families, 18 and 19 glycoside hydrolases. In addition to a catalytic domain, which is a triosephosphate isomerase barrel, many family 18 chitinases contain another module, i.e., chitinase insertion domain. While numerous studies focus on the biological role of the catalytic domain in chitinase activity, the function of the chitinase insertion domain is not completely understood. Bioinformatics offers an important avenue in which to facilitate understanding the role of residues within the chitinase insertion domain in chitinase function.Twenty-seven chitinase insertion domain sequences, which include four experimentally determined structures and span five kingdoms, were aligned and analyzed using a modified sequence entropy parameter. Thirty-two positions with conserved residues were identified. The role of these conserved residues was explored by conducting a structural analysis of a number of holo-enzymes. Hydrogen bonding and van der Waals calculations revealed a distinct subset of four conserved residues constituting two sequence motifs that interact with oligosaccharides. The other conserved residues may be key to the structure, folding, and stability of this domain.Sequence and structural studies of the chitinase insertion domains conducted within the framework of evolution identified four conserved residues which clearly interact with the substrates. Furthermore, evolutionary studies propose a link between the appearance of the chitinase insertion domain and the function of family 18 chitinases in the subfamily A.

  3. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  4. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  5. A methodology for spacecraft technology insertion analysis balancing benefit, cost, and risk

    Science.gov (United States)

    Bearden, David Allen

    , cost, and schedule; assessment of system level impacts of technology insertion; procedures for estimating uncertainties (risks) associated with advanced technology; and application of heuristics to facilitate informed system-level technology utilization decisions earlier in the conceptual design phase. MERIT extends the state of the art in technology insertion assessment selection practice and, if adopted, may aid designers in determining the configuration of complex systems that meet essential requirements in a timely, cost-effective manner.

  6. Impact of endoscopic stent insertion on detection of viable circulating tumor cells from obstructive colorectal cancer.

    Science.gov (United States)

    Yamashita, Shinya; Tanemura, Masahiro; Sawada, Genta; Moon, Jeongho; Shimizu, Yosuke; Yamaguchi, Toshiki; Kuwai, Toshio; Urata, Yasuo; Kuraoka, Kazuya; Hatanaka, Nobutaka; Yamashita, Yoshinori; Taniyama, Kiyomi

    2018-01-01

    The placement of a self-expanding metallic stent (SEMS) in obstructive colorectal cancer (OCRC) is acknowledged to be a safe and effective procedure for the relief of obstruction. However, there is concern that shear forces acting on the tumor during stent expansion may release cancer cells into the circulation, resulting in a poor prognosis. The aim of the present study was to determine whether colonic stent insertion increases viable circulating tumor cells (v-CTCs). A telomerase-specific replication-selective adenovirus-expressing GFP (TelomeScanF35) detection system was used to detect v-CTCs in 8 OCRC patients with a SEMS before and after stent insertion and after surgical resection. In 7 patients, a SEMS was inserted as a bridge to surgery (BTS), and in one patient, a SEMS was inserted for palliation. Surgical resection (R0) was performed in 7 patients. Four patients had no v-CTCs before SEMS placement, two of four measurable patients had an increased number of v-CTCs after SEMS placement (1-3 v-CTCs), and one of two patients with increased v-CTCs developed distant lymphatic metastasis despite curative resection. Four patients had v-CTCs (1-19 cells) before SEMS placement, and two of these four patients had an increase in the number of v-CTCs (20-21 cells) after SEMS placement, while one of the four patients died early with distant metastasis. The present study demonstrated that endoscopic stent insertion for OCRC may result in tumor cell dissemination into the peripheral circulation and may induce distant metastases.

  7. Improved efficiency of nanoneedle insertion by modification with a cell-puncturing protein

    Science.gov (United States)

    Ryu, Seunghwan; Matsumoto, Yuta; Matsumoto, Takahiro; Ueno, Takafumi; Silberberg, Yaron R.; Nakamura, Chikashi

    2018-03-01

    An atomic force microscope (AFM) probe etched into an ultra-sharp cylindrical shape (a nanoneedle) can be inserted into a living cell and mechanical responses of the insertion process are represented as force-distance curves using AFM. A probe-molecule-functionalized nanoneedle can be used to detect intracellular molecules of interest in situ. The insertion efficiencies of nanoneedles vary among cell types due to the cortex structures of cells, and some cell types, such as mouse fibroblast Balb/3T3 cells, show extremely low efficacy of insertion. We addressed this issue by using a cell membrane puncturing protein from bacteriophage T4 (gp5), a needle-like protein that spontaneously penetrates through the cell membrane. Gp5 was immobilized onto a nanoneedle surface. The insertion efficiency of the functionalized nanoneedle increased by over 15% compared to the non-functionalized control. Gp5-modification is a versatile approach in cell manipulation techniques for the insertion of other types of nanostructures into cells.

  8. Breaking the regioselectivity rule for acrylate insertion in the Mizoroki-Heck reaction.

    Science.gov (United States)

    Wucher, Philipp; Caporaso, Lucia; Roesle, Philipp; Ragone, Francesco; Cavallo, Luigi; Mecking, Stefan; Göttker-Schnetmann, Inigo

    2011-05-31

    In modern methods for the preparation of small molecules and polymers, the insertion of substrate carbon-carbon double bonds into metal-carbon bonds is a fundamental step of paramount importance. This issue is illustrated by Mizoroki-Heck coupling as the most prominent example in organic synthesis and also by catalytic insertion polymerization. For unsymmetric substrates H(2)C = CHX the regioselectivity of insertion is decisive for the nature of the product formed. Electron-deficient olefins insert selectively in a 2,1-fashion for electronic reasons. A means for controlling this regioselectivity is lacking to date. In a combined experimental and theoretical study, we now report that, by destabilizing the transition state of 2,1-insertion via steric interactions, the regioselectivity of methyl acrylate insertion into palladium-methyl and phenyl bonds can be inverted entirely to yield the opposite "regioirregular" products in stoichiometric reactions. Insights from these experiments will aid the rational design of complexes which enable a catalytic and regioirregular Mizoroki-Heck reaction of electron-deficient olefins.

  9. Probabilistic analysis and material characterisation of canister insert for spent nuclear fuel. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Claes-Goeran [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Andersson, Mats; Erixon, Bo [AaF Industriteknik, Stockholm (Sweden); Bjoerkegren, Lars-Erik [Swedish Foundry Association, Stockholm (Sweden); Dillstroem, Peter [DNV Technology, Stockholm (Sweden); Minnebo, Philip

    2005-11-15

    The KBS-3 canister for geological disposal of spent nuclear fuel in Sweden consists of a ductile cast iron insert and a copper shielding. The canister should inhibit release of radionuclides for at least 100,000 years. The copper protects the canister from corrosion whereas the ductile cast iron insert provides the mechanical strength. In the repository the hydrostatic pressure from the groundwater and the swelling pressure from the surrounding bentonite, which in total results in a maximum pressure of 14 MPa, will load the canisters in compression. During the extreme time scales, ice ages are expected with a maximum ice thickness of 3,000 m resulting in an additional pressure of 30 MPa. The maximum design pressure for the KBS-3 canisters has therefore been set to be 44 MPa. A relatively large number of canisters have been manufactured as part of SKB's development programme. To verify the strength of the canisters at this stage of development SKB initiated a project in cooperation with the European commissions Joint Research Centre (JRC), Institute of Energy in Petten in the Netherlands, together with a number of other partners. Three inserts manufactured by different Swedish foundries were used in the project. A large statistical test programme was developed to determine statistical distributions of various material parameters and defect distributions. These data together with the results from stress and strain finite element analysis were subsequently used in probabilistic analysis to determine the probability for plastic collapse caused by high pressure or fracture by crack growth in regions with tensile stresses. The main conclusions from the probabilistic analysis are: 1. At the design pressure of 44 MPa, the probability of failure is insignificant ({approx}2x10{sup -9}). This is the case even though several conservative assumptions have been made. 2. The stresses in the insert caused by the outer pressure are mainly compressive. The regions with tensile

  10. Evaluation of rod insertion issue for NPP Krsko

    International Nuclear Information System (INIS)

    Gunstek, A.; Kurincic, B.

    1998-01-01

    The last couple of years incident with control rods sticking in lower part of the fuel assemblies have been reported of several reactor operators and fuel vendors throughout of the world. Several activities were initiated immediately to determine the root cause of incomplete rod insertion. The purpose of this activities were to collect plants trip history data and testing results, review of available worldwide experience, review of plant operation and fuel management, detailed review of manufacturing and material property and to maintain detailed mechanical model. In this paper, we will present activities in Nuclear Power Plant Krsko which have been performed after NRC initiated the Root Cause Process (NRC Bulletin 96-01). NPP Krsko has not experienced rod insertion anomaly yet but anyway the additional tests were carried out. Rod drop time measurements that were performed normally at beginning of cycle at nominal temperature and pressure (HSB mode) have been extended also to end of cycle. Rod drop time, velocity of dropped rods and magnitudes of the initial recoil bounces vs. burnup were also analyzed. Also RCCA drag test with upper internals in place and drive shafts attached to RCCAs has been performed since then. At last two outages (1997 and 1998) drag test were carried out with digital scale meter to gather additional information. In addition to that, the reload core design has been performed with new constrains on rodded fuel assembly burnup as proposed by the industry.(author)

  11. Random insertion and gene disruption via transposon mutagenesis of Ureaplasma parvum using a mini-transposon plasmid.

    Science.gov (United States)

    Aboklaish, Ali F; Dordet-Frisoni, Emilie; Citti, Christine; Toleman, Mark A; Glass, John I; Spiller, O Brad

    2014-11-01

    While transposon mutagenesis has been successfully used for Mycoplasma spp. to disrupt and determine non-essential genes, previous attempts with Ureaplasma spp. have been unsuccessful. Using a polyethylene glycol-transformation enhancing protocol, we were able to transform three separate serovars of Ureaplasma parvum with a Tn4001-based mini-transposon plasmid containing a gentamicin resistance selection marker. Despite the large degree of homology between Ureaplasma parvum and Ureaplasma urealyticum, all attempts to transform the latter in parallel failed, with the exception of a single clinical U. urealyticum isolate. PCR probing and sequencing were used to confirm transposon insertion into the bacterial genome and identify disrupted genes. Transformation of prototype serovar 3 consistently resulted in transfer only of sequence between the mini-transposon inverted repeats, but some strains showed additional sequence transfer. Transposon insertion occurred randomly in the genome resulting in unique disruption of genes UU047, UU390, UU440, UU450, UU520, UU526, UU582 for single clones from a panel of screened clones. An intergenic insertion between genes UU187 and UU188 was also characterised. Two phenotypic alterations were observed in the mutated strains: Disruption of a DEAD-box RNA helicase (UU582) altered growth kinetics, while the U. urealyticum strain lost resistance to serum attack coincident with disruption of gene UUR10_137 and loss of expression of a 41 kDa protein. Transposon mutagenesis was used successfully to insert single copies of a mini-transposon into the genome and disrupt genes leading to phenotypic changes in Ureaplasma parvum strains. This method can now be used to deliver exogenous genes for expression and determine essential genes for Ureaplasma parvum replication in culture and experimental models. Copyright © 2014 Elsevier GmbH. All rights reserved.

  12. Semi-empirical master curve concept describing the rate capability of lithium insertion electrodes

    Science.gov (United States)

    Heubner, C.; Seeba, J.; Liebmann, T.; Nickol, A.; Börner, S.; Fritsch, M.; Nikolowski, K.; Wolter, M.; Schneider, M.; Michaelis, A.

    2018-03-01

    A simple semi-empirical master curve concept, describing the rate capability of porous insertion electrodes for lithium-ion batteries, is proposed. The model is based on the evaluation of the time constants of lithium diffusion in the liquid electrolyte and the solid active material. This theoretical approach is successfully verified by comprehensive experimental investigations of the rate capability of a large number of porous insertion electrodes with various active materials and design parameters. It turns out, that the rate capability of all investigated electrodes follows a simple master curve governed by the time constant of the rate limiting process. We demonstrate that the master curve concept can be used to determine optimum design criteria meeting specific requirements in terms of maximum gravimetric capacity for a desired rate capability. The model further reveals practical limits of the electrode design, attesting the empirically well-known and inevitable tradeoff between energy and power density.

  13. Characterization of GM events by insert knowledge adapted re-sequencing approaches.

    Science.gov (United States)

    Yang, Litao; Wang, Congmao; Holst-Jensen, Arne; Morisset, Dany; Lin, Yongjun; Zhang, Dabing

    2013-10-03

    Detection methods and data from molecular characterization of genetically modified (GM) events are needed by stakeholders of public risk assessors and regulators. Generally, the molecular characteristics of GM events are incomprehensively revealed by current approaches and biased towards detecting transformation vector derived sequences. GM events are classified based on available knowledge of the sequences of vectors and inserts (insert knowledge). Herein we present three insert knowledge-adapted approaches for characterization GM events (TT51-1 and T1c-19 rice as examples) based on paired-end re-sequencing with the advantages of comprehensiveness, accuracy, and automation. The comprehensive molecular characteristics of two rice events were revealed with additional unintended insertions comparing with the results from PCR and Southern blotting. Comprehensive transgene characterization of TT51-1 and T1c-19 is shown to be independent of a priori knowledge of the insert and vector sequences employing the developed approaches. This provides an opportunity to identify and characterize also unknown GM events.

  14. Internal Fiber Structure of a High-Performing, Additively Manufactured Injection Molding Insert

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Baier, Sina; Trinderup, Camilla H.

    A standard mold is equipped with additively manufactured inserts in a rectangular shape produced with vat photo polymerization. While the lifetime compared to conventional materials such as brass, steel, and aluminum is reduced, the prototyping and design phase can be shortened significantly...... by using flexible and cost-effective additive manufacturing technologies. Higher production volumes still exceed the capability of additively manufactured inserts, which are overruled by the stronger performance of less-flexible but mechanically advanced materials. In this contribution, the internal...... structure of a high-performing, fiber-reinforced injection molding insert has been analyzed. The insert reached a statistically proven and reproducible lifetime of 4,500 shots, which significantly outperforms any other previously published additively manufactured inserts. Computer tomography, tensile tests...

  15. Verification of Triple Modular Redundancy Insertion for Reliable and Trusted Systems

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth

    2016-01-01

    If a system is required to be protected using triple modular redundancy (TMR), improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process and the complexity of digital designs, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems.

  16. The Nucleoid Binding Protein H-NS Biases Genome-Wide Transposon Insertion Landscapes

    Directory of Open Access Journals (Sweden)

    Satoshi Kimura

    2016-08-01

    Full Text Available Transposon insertion sequencing (TIS; also known as TnSeq is a potent approach commonly used to comprehensively define the genetic loci that contribute to bacterial fitness in diverse environments. A key presumption underlying analyses of TIS datasets is that loci with a low frequency of transposon insertions contribute to fitness. However, it is not known whether factors such as nucleoid binding proteins can alter the frequency of transposon insertion and thus whether TIS output may systematically reflect factors that are independent of the role of the loci in fitness. Here, we investigated whether the histone-like nucleoid structuring (H-NS protein, which preferentially associates with AT-rich sequences, modulates the frequency of Mariner transposon insertion in the Vibrio cholerae genome, using comparative analysis of TIS results from wild-type (wt and Δhns V. cholerae strains. These analyses were overlaid on gene classification based on GC content as well as on extant genome-wide identification of H-NS binding loci. Our analyses revealed a significant dearth of insertions within AT-rich loci in wt V. cholerae that was not apparent in the Δhns insertion library. Additionally, we observed a striking correlation between genetic loci that are overrepresented in the Δhns insertion library relative to their insertion frequency in wt V. cholerae and loci previously found to physically interact with H-NS. Collectively, our findings reveal that factors other than genetic fitness can systematically modulate the frequency of transposon insertions in TIS studies and add a cautionary note to interpretation of TIS data, particularly for AT-rich sequences.

  17. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  18. Prevalence, risk factors and outcomes of velamentous and marginal cord insertions: a population-based study of 634,741 pregnancies.

    Directory of Open Access Journals (Sweden)

    Cathrine Ebbing

    Full Text Available OBJECTIVES: To determine the prevalence of, and risk factors for anomalous insertions of the umbilical cord, and the risk for adverse outcomes of these pregnancies. DESIGN: Population-based registry study. SETTING: Medical Birth Registry of Norway 1999-2009. POPULATION: All births (gestational age >16 weeks to <45 weeks in Norway (623,478 singletons and 11,263 pairs of twins. METHODS: Descriptive statistics and odds ratios (ORs for risk factors and adverse outcomes based on logistic regressions adjusted for confounders. MAIN OUTCOME MEASURES: Velamentous or marginal cord insertion. Abruption of the placenta, placenta praevia, pre-eclampsia, preterm birth, operative delivery, low Apgar score, transferral to neonatal intensive care unit (NICU, malformations, birthweight, and perinatal death. RESULTS: The prevalence of abnormal cord insertion was 7.8% (1.5% velamentous, 6.3% marginal in singleton pregnancies and 16.9% (6% velamentous, 10.9% marginal in twins. The two conditions shared risk factors; twin gestation and pregnancies conceived with the aid of assisted reproductive technology were the most important, while bleeding in pregnancy, advanced maternal age, maternal chronic disease, female foetus and previous pregnancy with anomalous cord insertion were other risk factors. Velamentous and marginal insertion was associated with an increased risk of adverse outcomes such as placenta praevia (OR = 3.7, (95% CI = 3.1-4.6, and placental abruption (OR = 2.6, (95% CI = 2.1-3.2. The risk of pre-eclampsia, preterm birth and delivery by acute caesarean was doubled, as was the risk of low Apgar score, transferral to NICU, low birthweight and malformations. For velamentous insertion the risk of perinatal death at term was tripled, OR = 3.3 (95% CI = 2.5-4.3. CONCLUSION: The prevalence of velamentous and marginal insertions of the umbilical cord was 7.8% in singletons and 16.9% in twin gestations, with marginal insertion being more

  19. ATLAS insertable B-layer

    Czech Academy of Sciences Publication Activity Database

    Marčišovský, Michal

    2011-01-01

    Roč. 633, č. 1 (2011), "S224"-"S225" ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA MŠk LA08015; GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * pixel detector * insertable B-layer Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011

  20. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    Science.gov (United States)

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  1. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  2. Inserts thermal coupling analysis in hexagonal honeycomb plates used for satellite structural design

    International Nuclear Information System (INIS)

    Boudjemai, A.; Mankour, A.; Salem, H.; Amri, R.; Hocine, R.; Chouchaoui, B.

    2014-01-01

    Mechanical joints and fasteners are essential elements in joining structural components in mechanical systems. The thermal coupling effect between the adjacent inserts depends to a great extent on the thermal properties of the inserts and the clearance. In this paper the Finite-Element Method (FEM) has been employed to study the insert thermal coupling behaviour of the hexagonal honeycomb panel. Fully coupled thermal analysis was conducted in order to predict thermal coupling phenomena caused by the adjacent inserts under extreme thermal loading conditions. Detailed finite elements models for a honeycomb panel are developed in this study including the insert joints. New approach of the adhesive joint is modelled. Thermal simulations showed that the adjacent inserts cause thermal interference and the adjacent inserts are highly sensitive to the effect of high temperatures. The clearance and thermal interference between the adjacent inserts have an important influence on the satellite equipments (such as the electronics box), which can cause the satellite equipments failures. The results of the model presented in this analysis are significant in the preliminary satellites structural dimensioning which present an effective approach of development by reducing the cost and the time of analysis. - Highlights: •In this work we perform thermal analysis of honeycomb plates using finite element method. •Detailed finite elements models for honeycomb panel are developed in this study including the insert joints. •New approach of the adhesive joint is modelled. •The adjacent inserts cause the thermal interference. •We conclude that this work will help in the analysis and the design of complex satellite structures

  3. Oral dextrose for analgesia in neonates during nasogastric tube insertion: a randomised controlled trial.

    Science.gov (United States)

    Ravishankar, Arjun; Thawani, Rajat; Dewan, Pooja; Das, Saurabhi; Kashyap, Archana; Batra, Prerna; Faridi, Moonis Mohammed Akbar

    2014-02-01

    This study aims to determine if oral dextrose solution can mitigate the pain response to nasogastric tube (NGT) insertion in neonates. The study was a double-blinded, placebo-controlled, randomised controlled trial. One hundred and fifty consecutive neonates were randomised into three groups to receive 25% dextrose (D25), or 10% dextrose (D10) or placebo (distilled water). An NGT was inserted after giving 2 mL of one of the solutions orally. Pain response was assessed using the Premature Infant Pain Profile (PIPP), and the duration of cry was noted within 60 s of the intervention. Total PIPP score, duration of cry, change in heart rate and oxygen saturation (SpO2 ) were compared among the three groups. Neonates who received D25 had significantly lesser pain response to NGT insertion in terms of lower PIPP score (P < 0.05) and duration of cry (P = 0.001) compared to D10. There was a significantly smaller increase in heart rate and decrease in SpO2 (P < 0.05). In comparison with placebo, D10 significantly decreased duration of cry (P < 0.05) but not PIPP score. Oral D25 was effective in reducing the pain response during NGT insertion in neonates when compared with oral D10 and placebo. Oral D10 was not found to have a potent analgesic effect for the same. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  4. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  5. Measurement of the radiation incident on ALS NdFeB permanent magnet insertion device structures and a determination of their lifetime

    International Nuclear Information System (INIS)

    Krebs, G.F.; Holmes, M.

    1997-05-01

    Measurements of the radiation incident on ALS insertion device NdFeB permanent magnet structures were carried out using thermoluminescence dosimeters. A plastic scintillator gamma telescope was utilized to unravel the various contributions to the integrated dose. Magnet lifetimes were calculated for various operational conditions

  6. Determination of membrane hydration numbers of alkali metal ions by insertion in a conducting polymer

    DEFF Research Database (Denmark)

    Skaarup, Steen; Junaid Mohamed Jafeen, Mohamed; Careem, M.A.

    2010-01-01

    , and a secondary (or outer) solvation shell, consisting of all other water molecules whose properties are still influenced significantly by the cation. Knowing the hydration number is important when considering, for instance, the transport of Na+ and K+ in biological cell membranes, since their different behavior...... may depend on the details of ion hydration. Although the solvation of alkali metal ions in aqueous solution has been discussed for many years, there is still no clear consensus. Part of the discrepancy is simply that different methods measure over different time scales, and therefore do...... not necessarily define the same hydration shell. This work presents a systematic study of one special variant of the hydration numbers of the 5 alkali metal ions, using the electrochemical insertion of the ions in a conducting polymer (polypyrrole containing the large immobile anion DBS-). The technique...

  7. Swirl flow analysis in a helical wire inserted tube using CFD code

    International Nuclear Information System (INIS)

    Park, Yusun; Chang, Soon Heung

    2010-01-01

    An analysis on the two-phase flow in a helical wire inserted tube using commercial CFD code, CFX11.0, was performed in bubbly flow and annular flow regions. The analysis method was validated with the experimental results of Takeshima. Bubbly and annular flows in a 10 mm inner diameter tube with varying pitch lengths and inserted wire diameters were simulated using the same analysis methods after validation. The geometry range of p/D was 1-4 and e/D was 0.08-0.12. The results show that the inserted wire with a larger diameter increased swirl flow generation. An increasing swirl flow was seen as the pitch length increased. Regarding pressure loss, smaller pitch lengths and inserted wires with larger diameters resulted in larger pressure loss. The average liquid film thickness increased as the pitch length and the diameter of the inserted wire increased in the annular flow region. Both in the bubbly flow and annular flow regions, the effect of pitch length on swirl flow generation and pressure loss was more significant than that of the inserted wire diameters. Pitch length is a more dominant factor than inserted wire diameter for the design of the swirl flow generator in small diameter tubes.

  8. Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.

    Science.gov (United States)

    Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde

    2016-11-01

    To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.

  9. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  10. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  11. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  12. Guide tube insert assembly for use in a nuclear reactor

    International Nuclear Information System (INIS)

    Hopkins, R.J.; Land, J.T.

    1992-01-01

    This patent describes an internals assembly for a nuclear reactor of the type including an upper support plate and an upper core plate, each having apertures for conducting control rod assemblies into an out of fuel assemblies with the apertures of the upper support plate being aligned with the apertures of the upper core plate, a guide tube insert assembly comprising: an elongated tubular body extending between at least one of the aligned apertures formed in the upper support plate and the upper core plate; guide plates within the elongated tubular body, each of the guide plates having a planar surface extending substantially perpendicular to an axial direction of the tubular body; at least one interconnecting means for interconnecting the guide plates into a guide tube insert assembly such that the guide plates are simultaneously mountable within and removable from the elongated body, and the periphery of each of the guide plates is spaced apart from the inner walls of the elongated tubular body at every point when the insert assembly is mounted within the tubular body, and a stabilizing means for securing the lowermost guide plate of the guide tube insert assembly within the elongated tubular body to prevent rotational and lateral movement between the guide tube insert assembly and the tubular body

  13. Insertion of liquid crystal molecules into hydrocarbon monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Piotr, E-mail: ppopov@kent.edu; Mann, Elizabeth K. [Department of Physics, Kent State University, Kent, Ohio 44242 (United States); Lacks, Daniel J. [Department of Chemical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Jákli, Antal [Liquid Crystal Institute, Kent State University, Kent, Ohio 44242-0001 (United States)

    2014-08-07

    Atomistic molecular dynamics simulations were carried out to investigate the molecular mechanisms of vertical surface alignment of liquid crystals. We study the insertion of nCB (4-Cyano-4{sup ′}-n-biphenyl) molecules with n = 0,…,6 into a bent-core liquid crystal monolayer that was recently found to provide good vertical alignment for liquid crystals. The results suggest a complex-free energy landscape for the liquid crystal within the layer. The preferred insertion direction of the nCB molecules (core or tail first) varies with n, which can be explained by entropic considerations. The role of the dipole moments was found to be negligible. As vertical alignment is the leading form of present day liquid crystal displays (LCD), these results will help guide improvement of the LCD technology, as well as lend insight into the more general problem of insertion of biological and other molecules into lipid and surfactant layers.

  14. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  15. High aspect ratio catalytic reactor and catalyst inserts therefor

    Science.gov (United States)

    Lin, Jiefeng; Kelly, Sean M.

    2018-04-10

    The present invention relates to high efficient tubular catalytic steam reforming reactor configured from about 0.2 inch to about 2 inch inside diameter high temperature metal alloy tube or pipe and loaded with a plurality of rolled catalyst inserts comprising metallic monoliths. The catalyst insert substrate is formed from a single metal foil without a central supporting structure in the form of a spiral monolith. The single metal foil is treated to have 3-dimensional surface features that provide mechanical support and establish open gas channels between each of the rolled layers. This unique geometry accelerates gas mixing and heat transfer and provides a high catalytic active surface area. The small diameter, high aspect ratio tubular catalytic steam reforming reactors loaded with rolled catalyst inserts can be arranged in a multi-pass non-vertical parallel configuration thermally coupled with a heat source to carry out steam reforming of hydrocarbon-containing feeds. The rolled catalyst inserts are self-supported on the reactor wall and enable efficient heat transfer from the reactor wall to the reactor interior, and lower pressure drop than known particulate catalysts. The heat source can be oxygen transport membrane reactors.

  16. Family of pH-Low-Insertion-Peptides (pHLIPs)

    Science.gov (United States)

    Weerakkody, Dhammika; Moshnikova, Anna; Moshnikova, Valentina; Thakur, Mak; Rossi, Bethany; Engelman, Donald; Andreev, Oleg; Reshetnyak, Yana

    2012-02-01

    pHLIP (pH (Low) Insertion Peptide) is a novel delivery system for targeting of acidic diseased tissue such as solid tumors, sites of inflammation, arthritis and other pathological states. The molecular mechanism of pHLIP action is based on pH-dependent insertion and folding of pHLIP in membrane. We performed sequence variation and investigated 16 pHLIP variants with main goals of understanding the main principles of peptide-lipid interactions and tune delivery capability of pHLIP. The biophysical studies including thermodynamics and kinetics of the peptides interaction with a lipid bilayer of liposomes and cellular membranes were carried out. We found that peptides association to membrane at neutral and low pH could be modulated by 3-4 times. The apparent pK of transition from surface bound to membrane-inserted state could be tuned from 6.5 to 4.5. The rate of peptide's insertion across a bilayer could be enhanced 100 times compared to parent pHLIP. As a result, blood clearance and tumor targeting were modulated in a significant degree. The work is supported by NIH grants CA133890 to OAA, DME, YRK.

  17. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next-generat...

  18. Customizable engineered blood vessels using 3D printed inserts.

    Science.gov (United States)

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Mismatch analysis of humeral nailing. Antegrade versus retrograde insertion

    International Nuclear Information System (INIS)

    Mahaisavariya, B.; Jiamwatthanachai, P.; Aroonjarattham, P.; Aroonjarattham, K.; Wongcumchang, M.; Sitthiseripratip, K.

    2011-01-01

    Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. The results showed: the diameter of the medullary canal averaged 7.9-13.8 mm; the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. (author)

  20. Manganese oxide octahedral molecular sieves as insertion electrodes for rechargeable Mg batteries

    KAUST Repository

    Rasul, Shahid

    2013-11-01

    Magnesium has been inserted electrochemically into manganese oxide octahedral molecular sieves (OMS-5 MnO2) at room temperature. Discharge/charge profiles show that a large amount of Mg, i.e., 0.37 Mg/Mn can be inserted electrochemically using 1 M Mg(ClO4)2/AN electrolyte when OMS-5 is prepared in presence of acetylene black. X-ray diffraction analysis and discharge/charge profiles verify that a solid state solution reaction takes place upon Mg insertion into the host lattice with concurrent reduction of Mn4+ to Mn2+. However, upon each reduction of Mn by Mg insertion and resultant dissolution into electrolyte, decrease in the active compound occurs consequently. A low intrinsic electronic conductivity of OMS-5 was suggested to play a vital role in Mg insertion into the host. © 2013 Elsevier Ltd.

  1. Manganese oxide octahedral molecular sieves as insertion electrodes for rechargeable Mg batteries

    KAUST Repository

    Rasul, Shahid; Suzuki, Shinya; Yamaguchi, Shu; Miyayama, Masaru

    2013-01-01

    Magnesium has been inserted electrochemically into manganese oxide octahedral molecular sieves (OMS-5 MnO2) at room temperature. Discharge/charge profiles show that a large amount of Mg, i.e., 0.37 Mg/Mn can be inserted electrochemically using 1 M Mg(ClO4)2/AN electrolyte when OMS-5 is prepared in presence of acetylene black. X-ray diffraction analysis and discharge/charge profiles verify that a solid state solution reaction takes place upon Mg insertion into the host lattice with concurrent reduction of Mn4+ to Mn2+. However, upon each reduction of Mn by Mg insertion and resultant dissolution into electrolyte, decrease in the active compound occurs consequently. A low intrinsic electronic conductivity of OMS-5 was suggested to play a vital role in Mg insertion into the host. © 2013 Elsevier Ltd.

  2. Does insertion of intramuscular electromyographic electrodes alter motor behavior during locomotion?

    Science.gov (United States)

    Armour Smith, Jo; Kulig, Kornelia

    2015-06-01

    Intramuscular electromyography (EMG) is commonly used to quantify activity in the trunk musculature. However, it is unclear if the discomfort or fear of pain associated with insertion of intramuscular EMG electrodes results in altered motor behavior. This study examined whether intramuscular EMG affects locomotor speed and trunk motion, and examined the anticipated and actual pain associated with electrode insertion in healthy individuals and individuals with a history of low back pain (LBP). Before and after insertion of intramuscular electrodes into the lumbar and thoracic paraspinals, participants performed multiple repetitions of a walking turn at self-selected and controlled average speed. Low levels of anticipated and actual pain were reported in both groups. Self-selected locomotor speed was significantly increased following insertion of the electrodes. At the controlled speed, the amplitude of sagittal plane lumbo-pelvic motion decreased significantly post-insertion, but the extent of this change was the same in both groups. Lumbo-pelvic motion in the frontal and axial planes and thoraco-lumbar motion in all planes were not affected by the insertions. This study demonstrates that intramuscular EMG is an appropriate methodology to selectively quantify the activation patterns of the individual muscles in the paraspinal group, both in healthy individuals and individuals with a history of LBP. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Behavior of the monophosphate tungsten bronzes (PO2)4(WO3)2m (m = 7 and 8) in the course of electrochemical lithium insertion

    International Nuclear Information System (INIS)

    Martinez-de la Cruz, A.; Longoria Rodriguez, F.E.; Gonzalez, Lucy T.; Torres-Martinez, Leticia M.

    2007-01-01

    The electrochemical lithium insertion process has been studied in the family of monophosphate tungsten bronzes (PO 2 ) 4 (WO 3 ) 2m , where m = 7 and 8. Structural changes in the pristine oxides were followed as lithium insertion proceeded. Through potentiostatic intermittent technique the different processes which take place in the cathode during the discharge of the cell were analyzed. The nature of the bronzes Li x (PO 2 ) 4 (WO 3 ) 2m formed was determined by in situ X-ray diffraction experiments. These results have allowed establishing a correlation with the reversible/irreversible processes detected during the electrochemical lithium insertion

  4. Composition and structure of porcine digital flexor tendon-bone insertion tissues.

    Science.gov (United States)

    Chandrasekaran, Sandhya; Pankow, Mark; Peters, Kara; Huang, Hsiao-Ying Shadow

    2017-11-01

    Tendon-bone insertion is a functionally graded tissue, transitioning from 200 MPa tensile modulus at the tendon end to 20 GPa tensile modulus at the bone, across just a few hundred micrometers. In this study, we examine the porcine digital flexor tendon insertion tissue to provide a quantitative description of its collagen orientation and mineral concentration by using Fast Fourier Transform (FFT) based image analysis and mass spectrometry, respectively. Histological results revealed uniformity in global collagen orientation at all depths, indicative of mechanical anisotropy, although at mid-depth, the highest fiber density, least amount of dispersion, and least cellular circularity were evident. Collagen orientation distribution obtained through 2D FFT of histological imaging data from fluorescent microscopy agreed with past measurements based on polarized light microscopy. Results revealed global fiber orientation across the tendon-bone insertion to be preserved along direction of physiologic tension. Gradation in the fiber distribution orientation index across the insertion was reflective of a decrease in anisotropy from the tendon to the bone. We provided elemental maps across the fibrocartilage for its organic and inorganic constituents through time-of-flight secondary ion mass spectrometry (TOF-SIMS). The apatite intensity distribution from the tendon to bone was shown to follow a linear trend, supporting past results based on Raman microprobe analysis. The merit of this study lies in the image-based simplified approach to fiber distribution quantification and in the high spatial resolution of the compositional analysis. In conjunction with the mechanical properties of the insertion tissue, fiber, and mineral distribution results for the insertion from this may potentially be incorporated into the development of a structural constitutive approach toward computational modeling. Characterizing the properties of the native insertion tissue would provide the

  5. Life Cycle Assessment of Fiber-Reinforced Additive Manufacturing for Injection Molding Insert Production

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Stotz, Philippe Maurice; Bey, Niki

    2017-01-01

    Additively manufactured (AM) injection molding (IM) inserts have proved to be capable to substitute conventionally manufactured metal inserts with polymer-based insert enforced with short, virgin, unseized carbon fibers (CFs). It has been shown that the implementation of AM technology resulted......, this contribution provides a comparison of environmental performance of conventionally vs. additively manufactured inserts in a full life cycle perspective indicated in Figure 1, including materials, production, use and end-of-life (EoL) stages....

  6. The influence of solid particles density on parameters of multijet insert

    Directory of Open Access Journals (Sweden)

    Z. Niedźwiedzki

    2008-10-01

    Full Text Available Some dependences between solid particles density, chosen geometry and exploitation parameters of multijet inserts and developmentof laminar motion in continuous multijet sedimentation process, are presented in this paper. Results are obtained from the analysis of the multijet sedimentation model considering development of laminar motion of the suspension in the multijet insert conduit of the settling tank. The range of the researches covered, in particular, quantities necessary for designing inserts of multijet settling tanks finding application in purifying suspended solids in casting processes. Discussed problem has practical and cognitive meanings and is a base for more efficient designing multijet settling tanks inserts applied in iron and steel industry. Application of most efficient construction and exploitation parameters allows designing devices of lower dimensions what is especially advantageous in casting works.

  7. Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

    Science.gov (United States)

    Gazibegovic, Dzemal; Bero, Eva M

    2017-02-01

    The HiFocus Mid-Scala electrode is intended to improve hearing for individuals with severe-to-profound hearing loss by providing extended electrical coverage of the cochlea while minimizing trauma related to insertion. The electrode is appropriate for use with a wide range of surgical techniques, including either a cochleostomy or round window insertion, and the use of either a free-hand or tool-assisted approach. The objective of this survey was to evaluate how the HiFocus Mid-Scala electrode and insertion tools was used across a population of cochlear implant recipients of differing ages, audiologic profiles, and anatomical characteristics. The intent was to understand the type and frequency of surgical techniques applicable with the electrode, and to provide guidelines for clinical practice. Two questionnaires were completed by surgeons at implant centres located in the United States, Europe, and Asia. Before any surgeries were conducted, surgeons completed a questionnaire that assessed their overall cochlear implant surgical practice and preferences. Following each HiFocus Mid-Scala electrode insertion, surgeons completed a questionnaire that summarized their experience during that surgical procedure. Questionnaires were completed by 32 surgeons from 16 centres for a total of 143 surgeries (112 adults, 31 children). Most surgeons (62 %) preferred to insert the electrode via the round window or an extended round window compared with a cochleostomy (16 %), whereas the remaining 22 % indicated that they made an insertion choice based on presenting anatomy. Sixty-nine percent preferred a free-hand approach over using insertion tools. In 32 procedures, surgeons elected to deviate from an intended round window insertion to either an extended round window or cochleostomy approach.

  8. Archive-cup insert for liquid-metal sampling

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Filewicz, E.C.; Holmes, J.T.

    1975-01-01

    An insert for collecting liquid-metal samples within a vertical casing including an elongated housing with an upper and a lower overflow seal of annular shape is described. The lower seal includes a centrally located pedestal on which a sample cup is disposed. Liquid metal enters the annulus of the upper seal and overflows into the cup which fills and overflows into the lower seal. Liquid-metal overflow from the lower seal is discharged from the insert. On cooling, the liquid metal trapped within the seals solidifies to hermetically isolate the metal sample within the cup. The device is particularly applicable for use with sampling systems on liquid metal-cooled reactors. (U.S.)

  9. A New Formula to Estimate the Length of Right Upper Extremity Vein from Elbow Crease to Carina Calculated by Peripherally Inserted Central Catheter Insertion through Right Basilic Vein Puncture

    International Nuclear Information System (INIS)

    Cho, Hyun Hwan; Jeon, Eui Yong; Lee, Hyun Jung; Lee, Hyun; Koh, Sung Hye; Choi, Sun Young; Lee, Kwan Seop; Yoon, Dae Young; Im, Hyoung June

    2012-01-01

    To measure the length of the upper extremity vein between the elbow crease and the carina (elbow crease to carina length, ECL), to facilitate the appropriate positioning of the tip of the peripherally inserted central catheter (PICC). A total of 124 patients (64 men and 60 women; mean age 65.2 ± 15.4 years; range, 21-90 years) inserted with PICC through the right basilic vein under fluoroscopy were included in this retrospective study. The ECL was determined as follows: ECL = (distance from elbow crease to puncture site) + (the catheter length of PICC) - (distance from carina to catheter tip on post-procedural chest radiograph). We analyzed the relationship between ECL and patient height. The mean ECL through right basilic vein was 42.07 ±4.03 cm (27.5 to 52.2 cm). ECL was found to be significantly correlated with patient height: ECL (cm) = 0.24 X patient height (cm) + 3.75. The formula developed in our study would be helpful for predicting the optimal catheter length during a blind bedside procedure of PICC via the right basilic vein.

  10. Lesion insertion in the projection domain: Methods and initial results

    International Nuclear Information System (INIS)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-01-01

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  11. Lesion insertion in the projection domain: Methods and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  12. Lesion insertion in the projection domain: Methods and initial results.

    Science.gov (United States)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-12-01

    To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR

  13. Improving patient safety during insertion of peripheral venous catheters: an observational intervention study

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2013-11-01

    Full Text Available [english] Background: Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps.Methods: The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology. A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback, followed by a second observation period. During the last observation week, participants evaluated the intervention.Results: In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test. Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after. Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68

  14. Oxidation promotes insertion of the CLIC1 chloride intracellular channel into the membrane.

    Science.gov (United States)

    Goodchild, Sophia C; Howell, Michael W; Cordina, Nicole M; Littler, Dene R; Breit, Samuel N; Curmi, Paul M G; Brown, Louise Jennifer

    2009-12-01

    Members of the chloride intracellular channel (CLIC) family exist primarily as soluble proteins but can also auto-insert into cellular membranes to form ion channels. While little is known about the process of CLIC membrane insertion, a unique feature of mammalian CLIC1 is its ability to undergo a dramatic structural metamorphosis between a monomeric glutathione-S-transferase homolog and an all-helical dimer upon oxidation in solution. Whether this oxidation-induced metamorphosis facilitates CLIC1 membrane insertion is unclear. In this work, we have sought to characterise the role of oxidation in the process of CLIC1 membrane insertion. We examined how redox conditions modify the ability of CLIC1 to associate with and insert into the membrane using fluorescence quenching studies and a sucrose-loaded vesicle sedimentation assay to measure membrane binding. Our results suggest that oxidation of monomeric CLIC1, in the presence of membranes, promotes insertion into the bilayer more effectively than the oxidised CLIC1 dimer.

  15. An experimental investigation on heat transfer enhancement in the laminar flow of water/TiO2 nanofluid through a tube heat exchanger fitted with modified butterfly inserts

    Science.gov (United States)

    Venkitaraj, K. P.; Suresh, S.; Alwin Mathew, T.; Bibin, B. S.; Abraham, Jisa

    2018-03-01

    Nanofluids are advanced heat transfer fluids that exhibit thermal properties superior than that of the conventional fluids such as water, oil etc. This paper reports the experimental study on convective heat transfer characteristics of water based titanium dioxide nanofluids in fully developed flow through a uniformly heated pipe heat exchanger fitted with modified butterfly inserts. Nanofluids are prepared by dispersing TiO2 nanoparticles of average particle size 29 nm in deionized water. The heat transfer experiments are performed in laminar regime using nanofluids prepared with 0.1% and 0.3% volume fractions of TiO2 nanoparticles. The thermal performance characteristics of conventional butterfly inserts and modified butterfly inserts are also compared using TiO2 nanofluid. The inserts with different pitches 6 cm, 9 cm and 12 cm are tested to determine the effect of pitch distance of inserts in the heat transfer and friction. The experimental results showed that the modification made in the butterfly inserts were able to produce higher heat transfer than conventional butterfly inserts.

  16. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  17. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  18. Automatic insertion of simulated microcalcification clusters in a software breast phantom

    Science.gov (United States)

    Shankla, Varsha; Pokrajac, David D.; Weinstein, Susan P.; DeLeo, Michael; Tuite, Catherine; Roth, Robyn; Conant, Emily F.; Maidment, Andrew D.; Bakic, Predrag R.

    2014-03-01

    An automated method has been developed to insert realistic clusters of simulated microcalcifications (MCs) into computer models of breast anatomy. This algorithm has been developed as part of a virtual clinical trial (VCT) software pipeline, which includes the simulation of breast anatomy, mechanical compression, image acquisition, image processing, display and interpretation. An automated insertion method has value in VCTs involving large numbers of images. The insertion method was designed to support various insertion placement strategies, governed by probability distribution functions (pdf). The pdf can be predicated on histological or biological models of tumor growth, or estimated from the locations of actual calcification clusters. To validate the automated insertion method, a 2-AFC observer study was designed to compare two placement strategies, undirected and directed. The undirected strategy could place a MC cluster anywhere within the phantom volume. The directed strategy placed MC clusters within fibroglandular tissue on the assumption that calcifications originate from epithelial breast tissue. Three radiologists were asked to select between two simulated phantom images, one from each placement strategy. Furthermore, questions were posed to probe the rationale behind the observer's selection. The radiologists found the resulting cluster placement to be realistic in 92% of cases, validating the automated insertion method. There was a significant preference for the cluster to be positioned on a background of adipose or mixed adipose/fibroglandular tissues. Based upon these results, this automated lesion placement method will be included in our VCT simulation pipeline.

  19. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  20. Angiotensin-converting enzyme insertion/deletion gene ...

    Indian Academy of Sciences (India)

    Angiotensin-converting enzyme insertion/deletion gene polymorphism in cystic fibrosis patients. Sabrine Oueslati Sondess Hadj Fredj Hajer Siala Amina Bibi Hajer Aloulou Lamia Boughamoura Khadija Boussetta Sihem Barsaoui Taieb Messaoud. Research Note Volume 95 Issue 1 March 2016 pp 193-196 ...

  1. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Angiotensin Converting Enzyme Insertion/Deletion Gene Polymorphism: An Observational Study among Diabetic Hypertensive Subjects in Malaysia. ... Methods: The pharmacological effect of ACE inhibition on mean arterial pressure (MAP) and glomerular filtration rate (GFR) were observed among a total of 62 subjects for ...

  2. Hardening device, by inserts, of electronic component against radiation

    International Nuclear Information System (INIS)

    Val, C.

    1987-01-01

    The hardening device includes at least two materials, one with high atomic number with respect to the other. One of these materials is set as inserts in a layer of the other material. The hardening device is then made by stacking of such layers, the insert density varying from one layer to the other, making thus vary the atomic number resulting from the hardening device along its thickness, following a predefined law [fr

  3. Otological Findings Ten Years after Myringotomy with Tympanostomy Tube Insertion

    Directory of Open Access Journals (Sweden)

    Ali Goljanian Tabrizi

    2011-01-01

    Full Text Available Introduction: To study the long-term complications of tympanostomy tube insertion in young children 10 years after surgery.   Materials and Methods: In September 2011, the medical records of all patients who had undergone myringotomy with tympanostomy tube insertion between February 2000 and March 2001 at the two general hospitals of Isfahan University of Medical Sciences were studied. Of the 98 patients who fulfilled the inclusion criteria, 82 patients agreed to participate and were enrolled in the study. The complications of the operation were evaluated in these patients.   Results: Of the 164 ears that were operated on, myringosclerosis was found in 17.1%, atrophy of the tympanic membrane in 1.2%, permanent perforation of the tympanic membrane in 0.6% and tympanic membrane atelectasis in 0.6%. None of the patients developed cholesteatoma as a complication of tympanostomy tube insertion.   Conclusion:  Considering the low risk of serious complications after 10 years, tympanostomy tube insertion is a safe and effective treatment option in the treatment of otitis media with effusion.

  4. A comparison of buffered lidocaine versus ELA-Max before peripheral intravenous catheter insertions in children.

    Science.gov (United States)

    Luhmann, Janet; Hurt, Sarah; Shootman, Mario; Kennedy, Robert

    2004-03-01

    Peripheral intravenous catheter (PIV) insertion is a common, painful experience for many children in the pediatric emergency department. Although local anesthetics such as injected buffered lidocaine have been shown to be effective at reducing pain and anxiety associated with PIV insertion, they are not routinely used. ELA-Max, a topical local anesthetic, has the advantage of needle-free administration but has not been compared with buffered lidocaine for PIV insertion. To compare the reduction of pain and anxiety during PIV insertion provided by subcutaneous buffered 1% lidocaine or topical ELA-Max in children. A randomized trial in children 4 to 17 years old undergoing PIV insertion with 22-gauge catheters was conducted. Children received either buffered lidocaine or ELA-Max. Buffered lidocaine was administered by using 30-gauge needles to inject 0.1 to 0.2 mL subcutaneously just before PIV insertion. ELA-Max was applied to the skin and occluded with Tegaderm 30 minutes before PIV insertion. Self-reported Visual Analog Scale (VAS) questionnaires (rating on a scale of 1-10; 1 = no pain, anxiety) were completed by patients and their parents before PIV insertion to assess baseline perceptions about pain and anxiety associated with PIV insertion and immediately after PIV insertion to assess pain and anxiety associated with the experience. After PIV insertion, the nurse who inserted the PIV also completed a VAS questionnaire assessing technical difficulty and satisfaction with the local anesthesia. A blinded observer also completed a VAS questionnaire to assess pain and anxiety associated with the PIV insertion. Data were analyzed by using chi2 and t tests. Sixty-nine subjects were enrolled, and questionnaires were competed by all (mean age: 12.1 +/- 4.5 years; 61% female). There were no differences for buffered lidocaine and ELA-Max groups in age, gender, race, prior IV experience, or baseline pain and anxiety. There were no significant differences between buffered

  5. Low insertion loss SOI microring resonator integrated with nano-taper couplers

    DEFF Research Database (Denmark)

    Pu, Minhao; Frandsen, Lars Hagedorn; Ou, Haiyan

    2009-01-01

    We demonstrate a microring resonator working at TM mode integrated with nano-taper couplers with 3.6dB total insertion loss. The measured insertion loss of the nano-taper coupler was only 1.3dB for TM mode....

  6. Verification of Triple Modular Redundancy (TMR) Insertion for Reliable and Trusted Systems

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2016-01-01

    We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems. If a system is expected to be protected using TMR, improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. This manuscript addresses the challenge of confirming that TMR has been inserted without corruption of functionality and with correct application of the expected TMR topology. The proposed verification method combines the usage of existing formal analysis tools with a novel search-detect-and-verify tool. Field programmable gate array (FPGA),Triple Modular Redundancy (TMR),Verification, Trust, Reliability,

  7. Complete nucleotide sequence of CTX-M-15-plasmids from clinical Escherichia coli isolates: insertional events of transposons and insertion sequences.

    Directory of Open Access Journals (Sweden)

    Annemieke Smet

    Full Text Available BACKGROUND: CTX-M-producing Escherichia coli strains are regarded as major global pathogens. METHODOLOGY/PRINCIPAL FINDINGS: The nucleotide sequence of three plasmids (pEC_B24: 73801-bp; pEC_L8: 118525-bp and pEC_L46: 144871-bp from Escherichia coli isolates obtained from patients with urinary tract infections and one plasmid (pEC_Bactec: 92970-bp from an Escherichia coli strain isolated from the joint of a horse with arthritis were determined. Plasmid pEC_Bactec belongs to the IncI1 group and carries two resistance genes: bla(TEM-1 and bla(CTX-M-15. It shares more than 90% homology with a previously published bla(CTX-M-plasmid from E. coli of human origin. Plasmid pEC_B24 belongs to the IncFII group whereas plasmids pEC_L8 and pEC_L46 represent a fusion of two replicons of type FII and FIA. On the pEC_B24 backbone, two resistance genes, bla(TEM-1 and bla(CTX-M-15, were found. Six resistance genes, bla(TEM-1, bla(CTX-M-15, bla(OXA-1, aac6'-lb-cr, tetA and catB4, were detected on the pEC_L8 backbone. The same antimicrobial drug resistance genes, with the exception of tetA, were also identified on the pEC_L46 backbone. Genome analysis of all 4 plasmids studied provides evidence of a seemingly frequent transposition event of the bla(CTX-M-15-ISEcp1 element. This element seems to have a preferred insertion site at the tnpA gene of a bla(TEM-carrying Tn3-like transposon, the latter itself being inserted by a transposition event. The IS26-composite transposon, which contains the bla(OXA-1, aac6'-lb-cr and catB4 genes, was inserted into plasmids pEC_L8 and pEC_L46 by homologous recombination rather than a transposition event. Results obtained for pEC_L46 indicated that IS26 also plays an important role in structural rearrangements of the plasmid backbone and seems to facilitate the mobilisation of fragments from other plasmids. CONCLUSIONS: Collectively, these data suggests that IS26 together with ISEcp1 could play a critical role in the evolution of

  8. Mastery learning improves students skills in inserting intravenous access: a pre-post-study.

    Science.gov (United States)

    Friederichs, Hendrik; Brouwer, Britta; Marschall, Bernhard; Weissenstein, Anne

    2016-01-01

    Inserting peripheral venous catheters (PVCs) has been identified as a core competency for medical students. Because the performance - even of hygienic standards - of both students and novice physicians is frequently inadequate, medical faculties must focus on competence-based learning objectives and deliberate practice, features that are combined in mastery learning. Our aim was to determine the competency of students in inserting PVCs before and after an educational intervention. This study comprised a skills assessment with pre- and post-tests of a group of third-year students who received a simulation-based intervention. A newly established curriculum involved one hour of practice at inserting PVCs on simulators. Students were required to pass a test (total 21 points, pass mark 20 points) developed on the concept of mastery learning. An unannounced follow-up test was performed one week (8 days) after the intervention. The simulation center of the medical faculty in Muenster. Third-year students who received the intervention. One hundred and nine complete data sets were obtained from 133 students (82.5%). Most students (97.2%) passed the test after the intervention (mean score increase from 15.56 to 20.50, Pstudents' performance after one week (8 days): only 74.5% of participants passed this retest (mean score reduction from 20.50 to 20.06, Plearning is an effective form of teaching practical skills to medical students, allowing a thorough preparation for the challenges of daily clinical practice.

  9. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  10. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.

    Science.gov (United States)

    Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C

    2000-01-01

    Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel

  11. Effect of Needle Aspiration of Pneumothorax on Subsequent Chest Drain Insertion in Newborns

    DEFF Research Database (Denmark)

    Murphy, Madeleine C; Heiring, Christian; Doglioni, Nicoletta

    2018-01-01

    Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating pneumotho......Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating...... was 5 tertiary European neonatal intensive care units. Infants receiving respiratory support (endotracheal ventilation, continuous positive airway pressure, or supplemental oxygen >40%) who had a pneumothorax on CR that clinicians deemed needed treatment were eligible for inclusion. Interventions...... was inserted if clinicians deemed that the response was inadequate. For CD insertion, a drain was inserted between the ribs and was left in situ. Main Outcomes and Measures: The primary outcome was whether a CD was inserted on the side of the pneumothorax within 6 hours of diagnosis. Results: A total of 76...

  12. Effect of insertion depth on helical antenna performance in a muscle-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Reeves, J W; Meeson, S; Birch, M J [Department of Clinical Physics, Royal London Hospital, 56-76 Ashfield Street, London, E1 1BB (United Kingdom)

    2005-06-21

    Barrett's oesophagus is considered to increase the risk of cancer 30 fold. A set of helical microwave antennas was designed to investigate their potential use in the thermal therapy of Barrett's oesophagus. For treatment, a balloon filled with muscle-equivalent material encapsulates the antenna. The effects of insertion depth and coil-spacing on the thermal distribution produced by the antennas (20-35 mm) were characterized. The 35 mm helical antenna, with a coil-spacing of 3.6 mm resulted in uniform heating for an insertion depth of 40 mm. It was observed that the resultant temperature distribution produced, by the antennas, was dependent on the insertion depth within the phantom. For all antennas studied, deeper insertion resulted in two high intensity regions, approximately 1/4 and 3/4 along the antenna length. In contrast, shallow insertion resulted in predominant tip heating with undesirable heating at the phantom entry point. However, by manipulating the coil-spacing of the helix, uniform temperature profiles were achieved for a range of insertion depths.

  13. Percutaneous Endoscopic Gastrostomy Tube Insertion in Neurodegenerative Disease: A Retrospective Study and Literature Review

    Directory of Open Access Journals (Sweden)

    Pamela Sarkar

    2017-05-01

    Full Text Available Background/Aims With the notable exceptions of dementia, stroke, and motor neuron disease, relatively little is known about the safety and utility of percutaneous endoscopic gastrostomy (PEG tube insertion in patients with neurodegenerative disease. We aimed to determine the safety and utility of PEG feeding in the context of neurodegenerative disease and to complete a literature review in order to identify whether particular factors need to be considered to improve safety and outcome. Methods A retrospective case note review of patients referred for PEG insertion by neurologists in a single neuroscience center was conducted according to a pre-determined set of standards. For the literature review, we identified references from searches of PubMed, mainly with the search items “percutaneous endoscopic gastrostomy” and “neurology” or “neurodegenerative disease.” Results Short-term mortality and morbidity associated with PEG in patients with neurological disease were significant. Age greater than 75 years was associated with poor outcome, and a trend toward adverse outcome was observed in patients with low serum albumin. Conclusions This study highlights the relatively high risk of PEG in patients with neurodegenerative disease. We present points for consideration to improve outcome in this particularly vulnerable group of patients.

  14. Radiation dose measurements of the insertion devices using radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Alderman, J.; Semones, E.; Job, P. K.

    2004-01-01

    The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research [1,2]. Earlier investigations have exhibited varying degrees of demagnetization of these magnets [3] due to irradiation from electron beams [4,5,6], 60 Co γ-rays [5], and high-energy neutrons [7,8]. Radiation-induced demagnetization has been observed in the APS insertion devices [9] and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF) [4,6], where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL [10,11], resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10 6 rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs

  15. Additive manufacturing for the production of inserts for micro injection moulding

    DEFF Research Database (Denmark)

    Mischkot, Michael; Hansen, Hans Nørgaard; Pedersen, David Bue

    2015-01-01

    The production of inserts for micro injection moulding using additive manufacturing technology has the potential to greatly improve the efficiency of pilot production and reduce overall time to market. In this work, Digital Light Processing (DLP) was used to produce micro injection moulding inserts...

  16. Evolution of Additively Manufactured Injection Molding Inserts Investigated by Thermal Simulations

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Pedersen, David B.; Tosello, Guido

    Injection molding using inserts from vat polymerization, an additive manufacturing technology, has been investigated for pilot production and rapid prototyping purposes throughout the past years. A standard mold is equipped with additively manufactured inserts in a rectangular shape of (20 x 20 x 2...

  17. Utilization of next generation sequencing for analyzing transgenic insertions in plum

    Science.gov (United States)

    When utilizing transgenic plants, it is useful to know how many copies of the genes were inserted and the locations of these insertions in the genome. This information can provide important insights for the interpretation of transgene expression and the resulting phenotype. Traditionally, these qu...

  18. Determinism and randomness in the evolution of introns and sine inserts in mouse and human mitochondrial solute carrier and cytokine receptor genes.

    Science.gov (United States)

    Cianciulli, Antonia; Calvello, Rosa; Panaro, Maria A

    2015-04-01

    In the homologous genes studied, the exons and introns alternated in the same order in mouse and human. We studied, in both species: corresponding short segments of introns, whole corresponding introns and complete homologous genes. We considered the total number of nucleotides and the number and orientation of the SINE inserts. Comparisons of mouse and human data series showed that at the level of individual relatively short segments of intronic sequences the stochastic variability prevails in the local structuring, but at higher levels of organization a deterministic component emerges, conserved in mouse and human during the divergent evolution, despite the ample re-editing of the intronic sequences and the fact that processes such as SINE spread had taken place in an independent way in the two species. Intron conservation is negatively correlated with the SINE occupancy, suggesting that virus inserts interfere with the conservation of the sequences inherited from the common ancestor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Inertial confinement fusion target insertion concepts for the National Ignition Facility

    International Nuclear Information System (INIS)

    Laughon, G.J.; Schultz, K.R.

    1996-01-01

    The National Ignition Facility (NIF) will be used to demonstrate fusion ignition in a laboratory environment in order to support development of inertial fusion as a potential fusion energy source for civilian use. However, target insertion must first be addressed before inertial fusion can become a practical energy source. Since target insertion systems currently utilized are not suitable for multiple shots in quick succession, insertion concepts involving free-falling and artificially accelerated targets are developed and evaluated against a set of predetermined guidelines. It is shown that a system involving a fast retraction positioner would be suitable. 5 refs., 4 figs

  20. Folding and insertion thermodynamics of the transmembrane WALP peptide

    International Nuclear Information System (INIS)

    Bereau, Tristan; Bennett, W. F. Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-01-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA) n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence

  1. Folding and insertion thermodynamics of the transmembrane WALP peptide

    Energy Technology Data Exchange (ETDEWEB)

    Bereau, Tristan, E-mail: bereau@mpip-mainz.mpg.de [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany); Bennett, W. F. Drew [Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Pfaendtner, Jim [Department of Chemical Engineering, University of Washington, Seattle, Washington 98195 (United States); Deserno, Markus [Department of Physics, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Karttunen, Mikko [Department of Mathematics and Computer Science & Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, MetaForum, 5600 MB Eindhoven (Netherlands)

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA){sub n} (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  2. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  3. Inserts for nuclear fuel elements

    International Nuclear Information System (INIS)

    Cragg, P.J.

    1982-01-01

    An insert for a nuclear fuel pin which comprises a strip. The strip carries notches, which enable a coding arrangement to be carried on the strip. The notches may be of differing sizes and the coding on the strip includes identification and identification checking data. Each notch on the strip may give rise to a signal pulse which is counted by a detector to avoid errors. (author)

  4. Electrochemical zinc insertion into W18O49: Synthesis and characterization of new bronzes

    International Nuclear Information System (INIS)

    Martinez-de la Cruz, A.; Amador, U.; Rodriguez-Carvajal, J.; Garcia-Alvarado, F.

    2005-01-01

    Divalent zinc ions have been electrochemically inserted into W 18 O 49 , producing zinc bronzes. Under our experimental conditions, W 18 O 49 accepts zinc reversibly as a guest up to 0.9 ions per formula. The reaction seems to proceed through the formation of a solid solution in which the W-O framework of the parent oxide is maintained. The location of the Zn 2+ ions in the framework of W 18 O 49 has been determined by neutron diffraction on a chemically prepared sample having the composition Zn 0.34 W 18 O 49 . As a main result, we found that Zn prefers to insert in one of the four types of quadrangular tunnels. More precisely, it is displaced from the center to occupy a low coordination site. This result indicates that a significant covalent character exists in the Zn-O bond. - Graphical Abstract: The structure of Zn 0.36 W 18 O 49 projected along the b-axis

  5. Are insertion torque and early osseointegration proportional? A histologic evaluation.

    Science.gov (United States)

    Campos, Felipe E B; Jimbo, Ryo; Bonfante, Estevam A; Barbosa, Darceny Z; Oliveira, Maiolino T F; Janal, Malvin N; Coelho, Paulo G

    2015-11-01

    The objective of this histologic study was to determine the effect of three drilling protocols (oversized, intermediate, and undersized) on biologic responses to a single implant type at early healing periods (2 weeks in vivo) in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, each dog received three Unitite implants, 4 mm in diameter by 10 mm in length, in bone sites drilled to 3.5, 3.75, and 4.0 mm in final diameter. The insertion torque was recorded during surgery, and bone-to-implant contact (BIC), and bone area fraction occupied (BAFO) measured from the histology. Each outcome measure was compared between treatment conditions with the Wilcoxon signed-rank test. Bonferroni-corrected statistical significance was set to 95%. Insertion torque increased as an inverse function of drilling diameter, as indicated by significant differences in torque levels between each pair of conditions (P = 0.005). BIC and BAFO levels were highest and statistically similar in the recommended and undersized conditions and significantly reduced in the oversized condition (P torque (primary stability). While BIC and BAFO were maximized when drilling the recommended diameter hole, only the oversized hole resulted in evidence of statistically reduced integration. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Human-specific HERV-K insertion causes genomic variations in the human genome.

    Directory of Open Access Journals (Sweden)

    Wonseok Shin

    Full Text Available Human endogenous retroviruses (HERV sequences account for about 8% of the human genome. Through comparative genomics and literature mining, we identified a total of 29 human-specific HERV-K insertions. We characterized them focusing on their structure and flanking sequence. The results showed that four of the human-specific HERV-K insertions deleted human genomic sequences via non-classical insertion mechanisms. Interestingly, two of the human-specific HERV-K insertion loci contained two HERV-K internals and three LTR elements, a pattern which could be explained by LTR-LTR ectopic recombination or template switching. In addition, we conducted a polymorphic test and observed that twelve out of the 29 elements are polymorphic in the human population. In conclusion, human-specific HERV-K elements have inserted into human genome since the divergence of human and chimpanzee, causing human genomic changes. Thus, we believe that human-specific HERV-K activity has contributed to the genomic divergence between humans and chimpanzees, as well as within the human population.

  7. Estimating Rates of Fault Insertion and Test Effectiveness in Software Systems

    Science.gov (United States)

    Nikora, A.; Munson, J.

    1998-01-01

    In developing a software system, we would like to estimate the total number of faults inserted into a software system, the residual fault content of that system at any given time, and the efficacy of the testing activity in executing the code containing the newly inserted faults.

  8. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  9. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research December 2015; 14 (12): ... Available online at http://www.tjpr.org ... patients/consumers about PPI. ... the perception of outpatients of Karachi about ... Do you store the medication at the temperature specified in the package insert ... drugs available in local market of Pakistan was.

  10. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    Science.gov (United States)

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  11. A proposal for a drug information database and text templates for generating package inserts

    Directory of Open Access Journals (Sweden)

    Okuya R

    2013-07-01

    Full Text Available Ryo Okuya,1 Masaomi Kimura,2 Michiko Ohkura,2 Fumito Tsuchiya3 1Graduate School of Engineering and Science, 2Faculty of Engineering, Shibaura Institute of Technology, Tokyo, 3School of Pharmacy, International University of Health and Welfare, Tokyo, Japan Abstract: To prevent prescription errors caused by information systems, a database to store complete and accurate drug information in a user-friendly format is needed. In previous studies, the primary method for obtaining data stored in a database is to extract drug information from package inserts by employing pattern matching or more sophisticated methods such as text mining. However, it is difficult to obtain a complete database because there is no strict rule concerning expressions used to describe drug information in package inserts. The authors' strategy was to first build a database and then automatically generate package inserts by embedding data in the database using templates. To create this database, the support of pharmaceutical companies to input accurate data is required. It is expected that this system will work, because these companies can earn merit for newly developed drugs to decrease the effort to create package inserts from scratch. This study designed the table schemata for the database and text templates to generate the package inserts. To handle the variety of drug-specific information in the package inserts, this information in drug composition descriptions was replaced with labels and the replacement descriptions utilizing cluster analysis were analyzed. To improve the method by which frequently repeated ingredient information and/or supplementary information are stored, the method was modified by introducing repeat tags in the templates to indicate repetition and improving the insertion of data into the database. The validity of this method was confirmed by inputting the drug information described in existing package inserts and checking that the method could

  12. Rescuing Alu: recovery of new inserts shows LINE-1 preserves Alu activity through A-tail expansion.

    Directory of Open Access Journals (Sweden)

    Bradley J Wagstaff

    Full Text Available Alu elements are trans-mobilized by the autonomous non-LTR retroelement, LINE-1 (L1. Alu-induced insertion mutagenesis contributes to about 0.1% human genetic disease and is responsible for the majority of the documented instances of human retroelement insertion-induced disease. Here we introduce a SINE recovery method that provides a complementary approach for comprehensive analysis of the impact and biological mechanisms of Alu retrotransposition. Using this approach, we recovered 226 de novo tagged Alu inserts in HeLa cells. Our analysis reveals that in human cells marked Alu inserts driven by either exogenously supplied full length L1 or ORF2 protein are indistinguishable. Four percent of de novo Alu inserts were associated with genomic deletions and rearrangements and lacked the hallmarks of retrotransposition. In contrast to L1 inserts, 5' truncations of Alu inserts are rare, as most of the recovered inserts (96.5% are full length. De novo Alus show a random pattern of insertion across chromosomes, but further characterization revealed an Alu insertion bias exists favoring insertion near other SINEs, highly conserved elements, with almost 60% landing within genes. De novo Alu inserts show no evidence of RNA editing. Priming for reverse transcription rarely occurred within the first 20 bp (most 5' of the A-tail. The A-tails of recovered inserts show significant expansion, with many at least doubling in length. Sequence manipulation of the construct led to the demonstration that the A-tail expansion likely occurs during insertion due to slippage by the L1 ORF2 protein. We postulate that the A-tail expansion directly impacts Alu evolution by reintroducing new active source elements to counteract the natural loss of active Alus and minimizing Alu extinction.

  13. The Effectiveness of Self-Expandable Metallic Stent Insertion in Treating Right-Sided Colonic Obstruction: A Comparison between SEMS and Decompression Tube Placement and an Investigation of the Safety and Difficulties of SEMS Insertion in Right Colons

    Directory of Open Access Journals (Sweden)

    Rintaro Moroi

    2014-01-01

    Full Text Available Objectives. Self-expandable metallic stent (SEMS is widely used to treat malignant colonic obstruction. However, most reports about SEMS insertion have concentrated on the left colon. This study aimed to (1 investigate the effectiveness of SEMS insertion compared with conventional decompression tube for right-sided colonic obstruction and (2 compare the safety and technical success of SEMS insertion between left- and right-sided colonic obstructions. Methods. The data from thirty-seven patients who underwent SEMS or conventional decompression tube placement for malignant colonic obstruction in our hospital were analyzed retrospectively. Technical and clinical success, complications, and technical difficulties were analyzed. We compared the results between SEMS insertion and decompression tube placement in right colons and the outcomes of SEMS insertion between right- and left-sided colonic obstructions. Results. For right colons, the clinical success rate of SEMS insertion (100% was significantly higher than that of decompression tube placement (55.9%. Concerning SEMS insertion, the technical difficulty and safety of SEMS insertion were similar between right- and left-sided colonic obstructions. Conclusion. SEMS insertion for right-sided colon is significantly more effective than conventional decompression tube placement, and this procedure was safer and less technically challenging than expected. SEMS insertion should be considered for treating right-sided malignant colonic obstruction.

  14. Perforation of the Esophagus Secondary to Insertion of Covered Wallstent Endoprostheses

    International Nuclear Information System (INIS)

    Farrugia, Mark; Morgan, Robert A.; Latham, Jennifer A.; Glynos, Michael; Mason, Robert C.; Adam, Andreas

    1997-01-01

    Perforation of the esophagus is a very rare complication of metallic esophageal stent insertion. Two cases are presented in which esophageal perforations were caused by the sharp ends of metallic stents impinging on the esophageal wall. In retrospect, both perforations might have been prevented by additional stent insertion

  15. Insert Modifications Improve Access to Artificial Red-Cockaded Woodpecker Next Cavities

    Science.gov (United States)

    John W. Edwards; Ernest E. Stevens; Charles A. Dachelet

    1997-01-01

    A designfor a modified, artificial Red-cockaded Woodpecker(Picoides borealis) cavity insert is presented. This modification allowed eggs and young to be inspected easily, removed, and replaced throughout the nesting period. Modifications to cavity inserts are best done before installation, but can be easily retrofitted in existing artificial cavities...

  16. A note on the insertion of rumen cannulae in pregnant ewes

    African Journals Online (AJOL)

    Modifications to a simple and rapid technique for the insertion of rumen cannulae in sheep are described. The modified technique, executed in three phases, was developed to facilitate the fistula- tion and insertion of rumen cannulae in pregnant ewes, especially during late pregnancy. Wysigings van 'n eenvoudige en ...

  17. the clinical anatomy of the insertion of the rotator cuff tendons

    African Journals Online (AJOL)

    2016-09-07

    Sep 7, 2016 ... The rotator cuff (RC) insertions according to most anatomical texts are described as being separate. However, clear fusion of the RC tendon fibres exist with prior studies showing an interdigitation forming a common, continuous insertion onto and around the lesser- and greater tubercles (LT & GT).

  18. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  19. Validation of a Low Cost, Disposable, and Ultrasound-guided Suprapubic Catheter Insertion Trainer.

    Science.gov (United States)

    Nonde, James; Adam, Ahmed; Laher, Abdullah Ebrahim

    2018-02-27

    To validate the newly designed ultrasound-guided suprapubic catheter insertion trainer (US-SCIT) model against the real life experience by enrolling participants with prior confidence in the technique of US-guided suprapubic catheter (SPC) insertion. The US-SCIT was self-constructed from common disposables and equipment found in the emergency department. A validation questionnaire was completed by all participants after SPC insertion on the US-SCIT model. Fifty participants enrolled in the study. Each participant had reported confidence in the SPC insertion technique, prior to participation in this study. There were 13 "super-users" (>65 previous successful real life SPC insertions) in the study. The total material cost per US-SCIT unit was 1.71 USD. The US-SCIT's value in understanding the principals of US-guided SPC insertion had a mean score of 8.86 (standard deviation [SD] 1.03), whereas its value in simulating contextual anatomy had a mean score of 8.26 (SD 1.48). The mean score of the model's ability to provide realistic sensory feedback was 8.12 (SD 1.78), whereas that of realism of initial urine outflow was 9.06 (SD 1.20). Simulation with the model compared well with real life SPC insertion, with a mean score of 8.30 (SD1.48). The US-SCIT model performed well in various spheres developed to assess its ability to simulate real life SPC insertion. We are confident that this low-cost, validated, US compatible SPC trainer, constructed from common material present in the ED, will be a valuable learning asset to trainees across the globe. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Assessment of Insert Sizes and Adapter Content in Fastq Data from NexteraXT Libraries

    Directory of Open Access Journals (Sweden)

    Frances Susan Turner

    2014-01-01

    Full Text Available The Illumina NexteraXT transposon protocol is a cost effective way to generate paired end libraries. However the resulting insert size is highly sensitive to the concentration of DNA used, and the variation of insert sizes is often large. One consequence of this is some fragments may have an insert shorter than the length of a single read, particularly where the library is designed to produce overlapping paired end reads in order to produce longer continuous sequences. Such small insert sizes mean fewer longer reads, and also result in the presence of adapter at the end of the read. Here is presented a protocol to use publicly available tools to identify read pairs with small insert sizes and so likely to contain adapter, to check the sequence of the adapter, and remove adapter sequence from the reads. This protocol does not require a reference genome or prior knowledge of the sequence to be trimmed. Whilst the presence of fragments with small insert sizes may be a particular problem for NexteraXT libraries, the principle can be applied to any Illumina dataset in which the presence of such small inserts is suspected.

  1. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  2. Titanium Insertion into CO Bonds in Anionic Ti-CO2 Complexes.

    Science.gov (United States)

    Dodson, Leah G; Thompson, Michael C; Weber, J Mathias

    2018-03-22

    We explore the structures of [Ti(CO 2 ) y ] - cluster anions using infrared photodissociation spectroscopy and quantum chemistry calculations. The existence of spectral signatures of metal carbonyl CO stretching modes shows that insertion of titanium atoms into C-O bonds represents an important reaction during the formation of these clusters. In addition to carbonyl groups, the infrared spectra show that the titanium center is coordinated to oxalato, carbonato, and oxo ligands, which form along with the metal carbonyls. The presence of a metal oxalato ligand promotes C-O bond insertion in these systems. These results highlight the affinity of titanium for C-O bond insertion processes.

  3. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  4. Histopathologic Consideration of Fiducial Gold Markers Inserted for Real-Time Tumor-Tracking Radiotherapy Against Lung Cancer

    International Nuclear Information System (INIS)

    Imura, Mikado; Yamazaki, Koichi; Kubota, Kanako C.; Itoh, Tomoo; Onimaru, Rikiya; Cho, Yasushi; Hida, Yasuhiro; Kaga, Kichizo; Onodera, Yuya; Ogura, Shigeaki; Dosaka-Akita, Hirotoshi; Shirato, Hiroki; Nishimura, Masaharu

    2008-01-01

    Purpose: Internal fiducial gold markers, safely inserted with bronchoscopy, have been used in real-time tumor-tracking radiotherapy for lung cancer. We investigated the histopathologic findings at several points after the insertion of the gold markers. Methods and Materials: Sixteen gold markers were inserted for preoperative marking in 7 patients who subsequently underwent partial resection of tumors by video-assisted thoracoscopic surgery within 7 days. Results: Fibrotic changes and hyperplasia of type 2 pneumocytes around the markers were seen 5 or 7 days after insertion, and fibrin exudation without fibrosis was detected 1 or 2 days after insertion. Conclusions: Because fibroblastic changes start approximately 5 days after gold marker insertion, real-time tumor-tracking radiotherapy should be started >5 days after gold marker insertion

  5. Characterization of the relationship between APOBEC3B deletion and ACE Alu insertion.

    Directory of Open Access Journals (Sweden)

    Kang Wang

    Full Text Available The insertion/deletion (I/D polymorphism of the angiotensin converting enzyme (ACE, commonly associated with many diseases, is believed to have affected human adaptation to environmental changes during the out-of-Africa expansion. APOBEC3B (A3B, a member of the cytidine deaminase family APOBEC3s, also exhibits a variable gene insertion/deletion polymorphism across world populations. Using data available from published reports, we examined the global geographic distribution of ACE and A3B genotypes. In tracking the modern human dispersal routes of these two genes, we found that the variation trends of the two I/D polymorphisms were directly correlated. We observed that the frequencies of ACE insertion and A3B deletion rose in parallel along the expansion route. To investigate the presence of a correlation between the two polymorphisms and the effect of their interaction on human health, we analyzed 1199 unrelated Chinese adults to determine their genotypes and other important clinical characteristics. We discovered a significant difference between the ACE genotype/allele distribution in the A3B DD and A3B II/ID groups (P = 0.045 and 0.015, respectively, indicating that the ACE Alu I allele frequency in the former group was higher than in the latter group. No specific clinical phenotype could be associated with the interaction between the ACE and A3B I/D polymorphisms. A3B has been identified as a powerful inhibitor of Alu retrotransposition, and primate A3 genes have undergone strong positive selection (and expansion for restricting the mobility of endogenous retrotransposons during evolution. Based on these findings, we suggest that the ACE Alu insertion was enabled (facilitated by the A3B deletion and that functional loss of A3B provided an opportunity for enhanced human adaptability and survival in response to the environmental and climate challenges arising during the migration from Africa.

  6. Analysis of plastic deformation in cortical bone after insertion of coated and non-coated self-tapping orthopaedic screws.

    Science.gov (United States)

    Koistinen, A P; Korhonen, H; Kiviranta, I; Kröger, H; Lappalainen, R

    2011-07-01

    Insertion of internal fracture fixation devices, such as screws, mechanically weakens the bone. Diamond-like carbon has outstanding tribology properties which may decrease the amount of damage in tissue. The purpose of this study was to investigate methods for quantification of cortical bone damage after orthopaedic bone screw insertion and to evaluate the effect of surface modification on tissue damage. In total, 48 stainless steel screws were inserted into cadaver bones. Half of the screws were coated with a smooth amorphous diamond coating. Geometrical data of the bones was determined by peripheral quantitative computed tomography. Thin sections of the bone samples were prepared after screw insertion, and histomorphometric evaluation of damage was performed on images obtained using light microscopy. Micro-computed tomography and scanning electron microscopy were also used to examine tissue damage. A positive correlation was found between tissue damage and the geometric properties of the bone. The age of the cadaver significantly affected the bone mineral density, as well as the damage perimeter and diameter of the screw hole. However, the expected positive effect of surface modification was probably obscured by large variations in the results and, thus, statistically significant differences were not found in this study. This can be explained by natural variability in bone tissue, which also made automated image analysis difficult.

  7. Comparing insertion libraries in two Pseudomonas aeruginosa strains to assess gene essentiality.

    Science.gov (United States)

    Liberati, Nicole T; Urbach, Jonathan M; Thurber, Tara K; Wu, Gang; Ausubel, Frederick M

    2008-01-01

    Putative essential genes can be identified by comparing orthologs not disrupted in multiple near-saturated transposon insertion mutation libraries in related strains of the same bacterial species. Methods for identifying all orthologs between two bacterial strains and putative essential orthologs are described. In addition, protocols detailing near-saturation transposon insertion mutagenesis of bacteria are presented, including (1) conjugation-mediated mutagenesis, (2) automated colony picking and liquid handling of mutant cultures, and (3) arbitrary polymerase chain reaction amplification and sequencing of genomic DNA adjacent to transposon insertion sites.

  8. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  9. Deep round window insertion versus standard approach in cochlear implant surgery.

    Science.gov (United States)

    Nordfalk, Karl Fredrik; Rasmussen, Kjell; Bunne, Marie; Jablonski, Greg Eigner

    2016-01-01

    The aim of this study was to compare the outcomes of vestibular tests and the residual hearing of patients who have undergone full insertion cochlear implant surgery using the round window approach with a hearing preservation protocol (RW-HP) or the standard cochleostomy approach (SCA) without hearing preservation. A prospective study of 34 adults who underwent unilateral cochlear implantation was carried out. One group was operated using the RW-HP (n = 17) approach with Med-El +Flex(SOFT) electrode array with full insertion, while the control group underwent a more conventional SCA surgery (n = 17) with shorter perimodiolar electrodes. Assessments of residual hearing, cervical vestibular-evoked myogenic potentials (cVEMP), videonystagmography, subjective visual vertical/horizontal (SVH/SVV) were performed before and after surgery. There was a significantly (p < 0.05) greater number of subjects who exhibited complete or partial hearing preservation in the deep insertion RW-HP group (9/17) compared to the SCA group (2/15). A higher degree of vestibular loss but a lower degree of vertigo symptoms could be seen in the RW-HP group, but the differences were not statistically significant. It is possible to preserve residual hearing to a certain extent also with deep insertion. Full insertion with hearing preservation was less harmful to residual hearing particularly at 125 Hz (p < 0.05), than was the standard cochleostomy approach.

  10. The effect of implant design and bone quality on insertion torque, resonance frequency analysis, and insertion energy during implant placement in low or low- to medium-density bone.

    Science.gov (United States)

    Wang, Tong-Mei; Lee, Ming-Shu; Wang, Juo-Song; Lin, Li-Deh

    2015-01-01

    This study investigated the effect of implant design and bone quality on insertion torque (IT), implant stability quotient (ISQ), and insertion energy (IE) by monitoring the continuous change in IT and ISQ while implants were inserted in artificial bone blocks that simulate bone of poor or poor-to-medium quality. Polyurethane foam blocks (Sawbones) of 0.16 g/cm³ and 0.32 g/cm³ were respectively used to simulate low density and low- to medium-density cancellous bone. In addition, some test blocks were laminated with a 1-mm 0.80 g/cm³ polyurethane layer to simulate cancellous bone with a thin cortical layer. Four different implants (Nobel Biocare Mk III-3.75, Mk III-4.0, Mk IV-4.0, and NobelActive-4.3) were placed into the different test blocks in accordance with the manufacturer's instructions. The IT and ISQ were recorded at every 0.5-mm of inserted length during implant insertion, and IE was calculated from the torque curve. The peak IT (PIT), final IT (FIT), IE, and final ISQ values were statistically analyzed. All implants showed increasing ISQ values when the implant was inserted more deeply. In contrast to the ISQ, implants with different designs showed dissimilar IT curve patterns during the insertion. All implants showed a significant increase in the PIT, FIT, IE, and ISQ when the test-block density increased or when the 1-mm laminated layer was present. Tapered implants showed FIT or PIT values of more than 40 Ncm for all of the laminated test blocks and for the nonlaminated test blocks of low to medium density. Parallel-wall implants did not exhibit PIT or FIT values of more than 40 Ncm for all of the test blocks. NobelActive-4.3 showed a significantly higher FIT, but a significantly lower IE, than Mk IV-4.0. While the existence of cortical bone or implant designs significantly affects the dynamic IT profiles during implant insertion, it does not affect the ISQ to a similar extent. Certain implant designs are more suitable than others if high IT is

  11. Thermohydraulic performance comparision of compound inserts for a turbulent flow through a circular tube

    Directory of Open Access Journals (Sweden)

    Kapse Arvind A.

    2017-01-01

    Full Text Available Heat transfer and pressure drop characteristics of three different passive inserts are experimentally investigated for individual and compound insertion. Insert cross-section is altered along the length of test section for compound insertion. Test runs were conducted in a concentric circular tube in tube heat exchanger in the Reynolds number range of 8000 to 32000 with water as a working fluid. Enhancements in Nusselt number and friction factors are reported to be in the range of 38-234% and 55-524%, respectively, over plain tube. The average performance ratios based on equal pumping power are also reported and found in the range of 0.63-1.53. Based on experimental results, optimum combination for compound insertion is proposed.

  12. Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography.

    Science.gov (United States)

    Dietz, Aarno; Gazibegovic, Dzemal; Tervaniemi, Jyrki; Vartiainen, Veli-Matti; Löppönen, Heikki

    2016-12-01

    The aim of this study was to evaluate the insertion results and placement of the new Advanced Bionics HiFocus Mid-Scala (HFms) electrode array, inserted through the round window membrane, in eight fresh human temporal bones using cone beam computed tomography (CBCT). Pre- and post-insertion CBCT scans were registered to create a 3D reconstruction of the cochlea with the array inserted. With an image fusion technique both the bony edges of the cochlea and the electrode array in situ could accurately be determined, thus enabling to identify the exact position of the electrode array within the scala tympani. Vertical and horizontal scalar location was measured at four points along the cochlea base at an angular insertion depth of 90°, 180° and 270° and at electrode 16, the most basal electrode. Smooth insertion through the round window membrane was possible in all temporal bones. The imaging results showed that there were no dislocations from the scala tympani into the scala vestibule. The HFms electrode was positioned in the middle of the scala along the whole electrode array in three out of the eight bones and in 62 % of the individual locations measured along the base of the cochlea. In only one cochlea a close proximity of the electrode with the basilar membrane was observed, indicating possible contact with the basilar membrane. The results and assessments presented in this study appear to be highly accurate. Although a further validation including histopathology is needed, the image fusion technique described in this study represents currently the most accurate method for intracochlear electrode assessment obtainable with CBCT.

  13. Experimental determination of the electron effective masses and mobilities in each dimensionally-quantized subband in an InxGa1−xAs quantum well with InAs inserts

    International Nuclear Information System (INIS)

    Kulbachinskii, V. A.; Oveshnikov, L. N.; Lunin, R. A.; Yuzeeva, N. A.; Galiev, G. B.; Klimov, E. A.; Maltsev, P. P.

    2015-01-01

    HEMT structures with In 0.53 Ga 0.47 As quantum well are synthesized using molecular-beam epitaxy on InP substrates. The structures are double-side Si δ-doped so that two dimensionally-quantized subbands are occupied. The effect of the central InAs nanoinsert in the quantum well on the electron effective masses m* and mobilities in each subband is studied. For experimental determination of m*, the quantum μ q and transport μ t mobilities of the two-dimensional electron gas in each dimensionally-quantized subband, the Shubnikov-de Haas effect is measured at two temperatures of 4.2 and 8.4 K. The electron effective masses are determined by the temperature dependence of the oscillation amplitudes, separating the oscillations of each dimensionally-quantized subband. The Fourier spectra of oscillations are used to determine the electron mobilities μ q and μ t in each dimensionally-quantized subband. It is shown that m* decreases as the InAs-nanoinsert thickness d in the In 0.53 Ga 0.47 As quantum well and electron mobilities increase. The maximum electron mobility is observed at the insert thickness d = 3.4 nm

  14. Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?

    International Nuclear Information System (INIS)

    Kibriya, N.; Wilbraham, L.; Mullan, D.; Puro, P.; Vasileuskaya, S.; Edwards, D.W.; Laasch, H.-U.

    2013-01-01

    Aim: To assess the insertion procedure and performance of disc-retained gastrostomy tubes, recording complications and accidental displacements by prospective audit, and to determine whether primary placement of the tube off-licence was feasible. Materials and methods: Disc-retained 12 F single-lumen Monarch gastrostomy tubes (Enteral UK, Selby, UK) were inserted by three gastrointestinal interventional radiologists in a supra-regional cancer centre. The 12 F tubes required a 20 F peel-away sheath with four-point gastropexy fixation and were placed under conscious sedation, using electrocardiogram (EEG) bispectral index monitoring. Follow-up was performed in an in-house gastrostomy drop-in clinic at 1 week and 1 month, supplemented with weekly telephone follow-up. Patients also had open access to the gastrostomy drop-in clinic for immediate advice and complication management. Results: Eighteen patients underwent primary insertion of a Monarch gastrostomy tube over 5 months. A total of 6/18 (33%) tubes displaced; 4/18 (22%) completely, 2/18 (11%) occult into the peritoneum. Four of 18 (22%) patients developed infection at the stoma site. Due to the unexpectedly poor performance of the tube, the study was terminated early. Conclusion: Initial experience with the Monarch disc-retained gastrostomy tube demonstrates it unsuitable for primary placement with current protocols. In view of the potentially serious complications, the Medicines and Healthcare Products Regulatory Agency (MHRA) has been informed. A request has been made to the distributer to reassess the tube design and/or review the procedure promoted for primary placement

  15. Mastery learning improves students skills in inserting intravenous access: a pre-post-study

    Directory of Open Access Journals (Sweden)

    Friederichs, Hendrik

    2016-08-01

    Full Text Available Objective: Inserting peripheral venous catheters (PVCs has been identified as a core competency for medical students. Because the performance – even of hygienic standards – of both students and novice physicians is frequently inadequate, medical faculties must focus on competence-based learning objectives and deliberate practice, features that are combined in mastery learning. Our aim was to determine the competency of students in inserting PVCs before and after an educational intervention. Design: This study comprised a skills assessment with pre- and post-tests of a group of third-year students who received a simulation-based intervention. A newly established curriculum involved one hour of practice at inserting PVCs on simulators. Students were required to pass a test (total 21 points, pass mark 20 points developed on the concept of mastery learning. An unannounced follow-up test was performed one week (8 days after the intervention.Setting: The simulation center of the medical faculty in Muenster.Participants: Third-year students who received the intervention.Results: One hundred and nine complete data sets were obtained from 133 students (82.5%. Most students (97.2% passed the test after the intervention (mean score increase from 15.56 to 20.50, <0.001. There was a significant decrease in students’ performance after one week (8 days: only 74.5% of participants passed this retest (mean score reduction from 20.50 to 20.06, <0.001. Conclusion: Mastery learning is an effective form of teaching practical skills to medical students, allowing a thorough preparation for the challenges of daily clinical practice.

  16. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  17. Role of the import motor in insertion of transmembrane segments by the mitochondrial TIM23 complex.

    Science.gov (United States)

    Popov-Čeleketić, Dušan; Waegemann, Karin; Mapa, Koyeli; Neupert, Walter; Mokranjac, Dejana

    2011-06-01

    The TIM23 complex mediates translocation of proteins across, and their lateral insertion into, the mitochondrial inner membrane. Translocation of proteins requires both the membrane-embedded core of the complex and its ATP-dependent import motor. Insertion of some proteins, however, occurs in the absence of ATP, questioning the need for the import motor during lateral insertion. We show here that the import motor associates with laterally inserted proteins even when its ATPase activity is not required. Furthermore, our results suggest a role for the import motor in lateral insertion. Thus, the import motor is involved in ATP-dependent translocation and ATP-independent lateral insertion.

  18. Impact of hydrogen insertion on vehicular natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Strangueto, Karina Maretti; Silva, Ennio Peres da [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. of Mechanical Engineering. Energy Dept.], Email: karinakms@fem.unicamp.br

    2010-07-01

    This article aims to analyze the possibility of insertion of hydrogen in the vehicular natural gas or even the insertion of the hydrogen in the compressed natural gas used in Brazil. For the production of this hydrogen, the spilled turbinable energy from Itaipu would be harnessed. The calculation of production can be extended to other power plants which are close to the natural gas pipelines, where the hydrogen would be introduced. Then, it was analyzed the consumption of natural gas in vehicles in Brazil, the regulation of transportation, the sales of compressed natural gas to fuelling station, the specifications that the piped gas should follow to be sold, and how much hydrogen could be accepted in the mix. (author)

  19. Control and initial operation of the Fermilab BO low β insertion

    International Nuclear Information System (INIS)

    Finley, D.A.; Johnson, R.P.; Willeke, F.

    1985-06-01

    The operation of the Fermilab BO low β insertion involves the coordinated control of the 4 strings of quadrupoles of the insertion itself along with several magnetic correction elements (20 dipoles for the closed orbit, 2 quad circuits for betatron tunes, 1 skew quad circuit for coupling, and 2 sextupole circuits for chromaticity). When the beam is stored at high energy, these elements must correct the errors induced by the strong superconducting quadrupoles of the insertion as the optics are smoothly changed from the fixed target configuration to the low β state. The techniques and control programs for these manipulations and initial tests using a single coasting beam are described. 6 refs., 4 figs

  20. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  1. Targeted gene insertion for molecular medicine.

    Science.gov (United States)

    Voigt, Katrin; Izsvák, Zsuzsanna; Ivics, Zoltán

    2008-11-01

    Genomic insertion of a functional gene together with suitable transcriptional regulatory elements is often required for long-term therapeutical benefit in gene therapy for several genetic diseases. A variety of integrating vectors for gene delivery exist. Some of them exhibit random genomic integration, whereas others have integration preferences based on attributes of the targeted site, such as primary DNA sequence and physical structure of the DNA, or through tethering to certain DNA sequences by host-encoded cellular factors. Uncontrolled genomic insertion bears the risk of the transgene being silenced due to chromosomal position effects, and can lead to genotoxic effects due to mutagenesis of cellular genes. None of the vector systems currently used in either preclinical experiments or clinical trials displays sufficient preferences for target DNA sequences that would ensure appropriate and reliable expression of the transgene and simultaneously prevent hazardous side effects. We review in this paper the advantages and disadvantages of both viral and non-viral gene delivery technologies, discuss mechanisms of target site selection of integrating genetic elements (viruses and transposons), and suggest distinct molecular strategies for targeted gene delivery.

  2. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  3. Cowpea mosaic virus-based chimaeras Effects of inserted peptides on the phenotype, host range, and transmissibility of the modified viruses

    International Nuclear Information System (INIS)

    Porta, Claudine; Spall, Valerie E.; Findlay, Kim C.; Gergerich, Rose C.; Farrance, Christine E.; Lomonossoff, George P.

    2003-01-01

    Expression of foreign peptides on the surface of cowpea mosaic virus particles leads to the creation of chimaeras with a variety of phenotypes and yields. Two factors were shown to be particularly significant in determining the properties of a given chimaera: the length of the inserted sequence and its isoelectric point. The deleterious effect of high isoelectric point on the ability of chimeras to produce a systemic infection occurs irrespective of the site of insertion of the peptide. Ultrastructural analysis of tissue infected with chimaeras with different phenotypes showed that all produced particles with a tendency to aggregate, irrespective of the size or isoelectric point of the insert. Host range and transmission studies revealed that the expression of a foreign peptide did not (1) alter the virus host range, (2) increase the rate of transmission by beetles or through seed, or (3) change the insect vector specificity. These findings have implications for both the utility and the biosafety of Cowpea mosaic virus-based chimaeras

  4. Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

    International Nuclear Information System (INIS)

    Berthon, B.; Marshall, C.; Evans, M.; Spezi, E.

    2014-01-01

    Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible

  5. The Effect of Insertion Technique on Temperatures for Standard and Self-Drilling External Fixation Pins.

    Science.gov (United States)

    Manoogian, Sarah; Lee, Adam K; Widmaier, James C

    2017-08-01

    No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P drilling pin temperature increase was not significant. The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.

  6. Distal insertions of the semimembranosus tendon: MR imaging with anatomic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, Michel de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium); Shahabpour, Maryam; Milants, Annemieke; Ridder, Filip de; Mey, Johan de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Lenchik, Leon [Wake Forest University, Department of Radiology, Winston-Salem, NC (United States); Cattrysse, Erik [Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium)

    2014-06-15

    The purpose of this study is to investigate the distal insertions of the semimembranosus tendon with MR imaging, correlated with findings in cadavers. Four fresh cadaveric specimens were studied with 3-T MR imaging. Sequences included proton density (PD) sequences (TE, 13; TR, 4957; FOV, 170 x 170; matrix, 424 x 413; NA, 2; slice thickness, 2.5 mm) in the axial, coronal, and sagittal planes and 3D fast field echo (FFE) sequences (TR 9.4; TE 6.9; FOV, 159 x 105; matrix, 200 x 211; NA, 2; slice thickness, 0.57 mm). One specimen was dissected and three specimens were sectioned with a bandsaw in the axial, coronal, and sagittal plane. The sections were photographed and correlated with MR images. To standardize the analysis, the semimembranosus muscle and tendon were assessed at seven levels for the axial sections, and at three levels for the coronal and sagittal sections. Anatomic dissection revealed six insertions of the distal semimembranosus tendon: direct arm, anterior arm, posterior oblique ligament extension, oblique popliteal ligament extension, distal tibial expansion (popliteus aponeurosis), and meniscal arm. Axial MR images showed five of six insertions: direct arm, anterior arm, oblique popliteal ligament extension, posterior oblique ligament extension, and distal tibial expansion. Sagittal MR images showed four of six insertions: direct arm, anterior arm, oblique popliteal ligament arm, and distal tibial expansion. Sagittal MR images were ideal for showing the direct arm insertion, but were less optimal than the axial images for showing the other insertions. The anterior arm was seen but volume averaging was present with the gracilis tendon. Coronal MR images optimally revealed the anterior arm, although magic angle artifact was present at its posterior aspect. The common semimembranosus tendon and meniscal arm were also well depicted. The division in anterior arm, direct arm, and oblique popliteal ligament arm was poorly seen on coronal images due to

  7. Genome-wide LORE1 retrotransposon mutagenesis and high-throughput insertion detection in Lotus japonicus

    DEFF Research Database (Denmark)

    Urbanski, Dorian Fabian; Malolepszy, Anna; Stougaard, Jens

    2012-01-01

    Insertion mutants facilitate functional analysis of genes, but for most plant species it has been difficult to identify a suitable mutagen and to establish large populations for reverse genetics. The main challenge is developing efficient high-throughput procedures for both mutagenesis and insert......Insertion mutants facilitate functional analysis of genes, but for most plant species it has been difficult to identify a suitable mutagen and to establish large populations for reverse genetics. The main challenge is developing efficient high-throughput procedures for both mutagenesis...... plants. The identified insertions showed that the endogenous LORE1 retrotransposon is well suited for insertion mutagenesis due to its homogenous gene targeting and exonic insertion preference. Since LORE1 transposition occurs in the germline, harvesting seeds from a single founder line and cultivating...... progeny generates a complete mutant population. This ease of LORE1 mutagenesis combined with the efficient FSTpoolit protocol, which exploits 2D pooling, Illumina sequencing, and automated data analysis, allows highly cost-efficient development of a comprehensive reverse genetic resource....

  8. A non-canonical transferred DNA insertion at the BRI1 locus in Arabidopsis thaliana.

    Science.gov (United States)

    Zhao, Zhong; Zhu, Yan; Erhardt, Mathieu; Ruan, Ying; Shen, Wen-Hui

    2009-04-01

    Agrobacterium-mediated transformation is widely used in transgenic plant engineering and has been proven to be a powerful tool for insertional mutagenesis of the plant genome. The transferred DNA (T-DNA) from Agrobacterium is integrated into the plant genome through illegitimate recombination between the T-DNA and the plant DNA. Contrasting to the canonical insertion, here we report on a locus showing a complex mutation associated with T-DNA insertion at the BRI1 gene in Arabidopsis thaliana. We obtained a mutant line, named salade for its phenotype of dwarf stature and proliferating rosette. Molecular characterization of this mutant revealed that in addition to T-DNA a non-T-DNA-localized transposon from bacteria was inserted in the Arabidopsis genome and that a region of more than 11.5 kb of the Arabidopsis genome was deleted at the insertion site. The deleted region contains the brassinosteroid receptor gene BRI1 and the transcription factor gene WRKY13. Our finding reveals non-canonical T-DNA insertion, implicating horizontal gene transfer and cautioning the use of T-DNA as mutagen in transgenic research.

  9. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Calzos pentagonales cementados: influencia de la velocidad de corte en la productividad y los costos//Cemented pentagonal inserts: influence of cutting speed on productivity and costs

    Directory of Open Access Journals (Sweden)

    David Machín-Valle

    2013-09-01

    Full Text Available Las herramientas de corte con sujeción mecánica (calzos o insertos son utilizadas en procesos de mecanizado de alta productividad. El objetivo del trabajo consiste en determinar la influencia de la velocidad de corte del proceso de torneado en la productividad y los costos. En el estudio se emplearon calzos pentagonales de carburo cementado de producción nacional. Como material a elaborar fueutilizado el acero Cr12Mo, utilizándose varias velocidades de corte, manteniéndose constante el avance y la profundidad, hasta alcanzar el desgaste límite del flanco del calzo (0,5 mm para obtener la ecuación que relaciona la velocidad de corte y el tiempo de vida útil del calzo. También fue establecida la influencia de la velocidad de corte sobre los tiempos de maquinado y los costos productivos respectivamente. Por último, la velocidad de corte obtenida para máxima productividad es 255.45 m/min y para el menor costo 120,03 m/min.Palabras claves: torneado, calzos pentagonales, productividad, velocidad de corte.______________________________________________________________________________AbstractCutting tools with mechanical clamping (inserts are used in high productivity machining processes. The objective of the study was to determine the influence of turning process cutting speed on productivity and costs. Cuban pentagonal cemented carbide inserts were used. The turning of Cr12Mo was performed atvarious cutting speeds and remained constant feed and depth. The insert´s flank wear behavior and the equation that relates the cutting speed and the insert life were determined. The influence of the cutting speed on machining time and production costs respectively was established too. It was determined thatthe cutting speed for maximum productivity is 255.45 m / min and for the lowest cost is 120.03 m / min.Key words: turning, pentagonal inserts, productivity, cutting speed.

  11. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  12. Low voltage aluminium anodes. Optimization of the insert-anode bond

    Energy Technology Data Exchange (ETDEWEB)

    Le Guyader, Herve; Debout, Valerie; Grolleau, Anne-Marie [DCN Cherbourg, Departement 2EI, Place Bruat, BP 440, 50104 Cherbourg-Octeville (France); Pautasso, Jean-Pierre [DGA/CTA 16 bis, avenue Prieur de la Cote D' Or, 94 114 Arcueil Cedex (France)

    2004-07-01

    Zinc or Al/Zn/In sacrificial anodes are widely used to protect submerged marine structures from corrosion. Their Open Circuit Potential range from - 1 V vs. Ag/AgCl for Zn anodes to -1.1 V vs. Ag/AgCl for Al/Zn/In. These potentials are sufficiently electronegative as to reduce the threshold for stress corrosion cracking and/or hydrogen embrittlement, KISCC, especially in the presence of high strength alloys. In the 90's, an extensive research programme was initiated by DGA/DCN to implement a new low voltage material. Laboratory and full scale marine tests performed on industrial castings, as previously reported, led to the development of a new patented Al- 0.1%Ga alloy having a working potential of - 0.80 to - 0.83 V vs. Ag/AgCl. This alloy was also evaluated at full scale at the Naval Research Laboratory anode qualification site in Key West, Fl, and gave satisfactory results. Around 500 cylindrical AlGa anodes were then installed on a submerged marine structure replacing the classical zinc anode. A first inspection, carried out after a few months of service, showed that some of the anodes had not operated as expected, which led to further investigations. The examinations performed indicated that the problem was due to a bad metallurgical compatibility between the insert and the sacrificial materials inducing a poor bond between the anode and the plain rod insert. Progressive loss of contact between the anode and the structure to be protected was then induced by penetration of sea water and corrosion at the anode-insert interface. This phenomenon was aggravated by seawater pressure. Additional studies were therefore launched with two aims: (1) find temporary remedies for the anodes already installed on the structure; (2) correct the anode original design and/or manufacturing process to achieve the maximum performance on new anodes lots. This paper describes the various solutions investigated to improve the insert-anode bond: design of the anode, rugosity and

  13. Direct random insertion mutagenesis of Helicobacter pylori

    NARCIS (Netherlands)

    de Jonge, Ramon; Bakker, Dennis; van Vliet, Arnoud H. M.; Kuipers, Ernst J.; Vandenbroucke-Grauls, Christina M. J. E.; Kusters, Johannes G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  14. Direct random insertion mutagenesis of Helicobacter pylori.

    NARCIS (Netherlands)

    Jonge, de R.; Bakker, D.; Vliet, van AH; Kuipers, E.J.; Vandenbroucke-Grauls, C.M.J.E.; Kusters, J.G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  15. Transmission of chromosomal and instability via a chromosome irradiated with ionizing radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji; Tanabe, Masateru; Shiraishi, Kazunori; Oshimura, Mitsuo

    2010-01-01

    We examined the stability of the transferred chromosome in 5 and 12 microcell hybrids including unirradiated human chromosomes 6 and 8, respectively, and 6 and 19 microcell hybrids including 4 Gy-irradiated human chromosomes 6 and 8, respectively. The transferred chromosome was structurally stable in most microcell hybrids transferred with the unirradiated chromosomes 6 and 8. In contrast, the 4 Gy-irradiated human chromosomes were unstable in 3 out of 6 hybrids (50%) with chromosome 6 and 3 out of 19 hybrids (16%) with chromosome 8, showing multiple aberrations in high frequencies (35∼98%). To know the cause of delayed chromosomal instability, intrachromosomal rearrangements of the human chromosome is investigated by subtelomere FISH in 17 microcell hybrids transferred with chromosomes 6 and 8. We found frequent intrachromosomal in 7 microcell hybrids (41%). However, no clear correlation was observed between the intrachromosomal rearrangements and the induction of delayed chromosomal instability by ionizing radiation

  16. Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening.

    Directory of Open Access Journals (Sweden)

    Mercy Nyamewaa Asiedu

    Full Text Available Cervical cancer screening usually requires use of a speculum to provide a clear view of the cervix. The speculum is one potential barrier to screening due to fear of pain, discomfort and embarrassment. The aim of this paper is to present and demonstrate the feasibility of a tampon-sized inserter and the POCkeT Colposcope, a miniature pen sized-colposcope, for comfortable, speculum-free and potentially self-colposcopy.We explored different designs using 3D computer-aided design (CAD software and performed mechanical testing simulations on each. Designs were rapid prototyped and tested using a custom vaginal phantom across a range of vaginal pressures and uterine tilts to select an optimal design. Two final designs were tested with fifteen volunteers to assess cervix visualization, comfort and usability compared to the speculum and the optimal design, the curved-tip inserter, was selected for testing in volunteers.We present a vaginal inserter as an alternative to the standard speculum for use with the POCkeT Colposcope. The device has a slim tubular body with a funnel-like curved tip measuring approximately 2.5 cm in diameter. The inserter has a channel through which a 2 megapixel (MP mini camera with LED illumination fits to enable image capture. Mechanical finite element testing simulations with an applied pressure of 15 cm H2O indicated a high factor of safety (90.9 for the inserter. Testing of the device with a custom vaginal phantom, across a range of supine vaginal pressures and uterine tilts (retroverted, anteverted and sideverted, demonstrated image capture with a visual area comparable to the speculum for a normal/axial positioned uteri and significantly better than the speculum for anteverted and sideverted uteri (p<0.00001. Volunteer studies with self-insertion and physician-assisted cervix image capture showed adequate cervix visualization for 83% of patients. In addition, questionnaire responses from volunteers indicated a 92

  17. A multiple objective magnet sorting algorithm for the ALS insertion devices

    International Nuclear Information System (INIS)

    Humphries, D.; Goetz, F.; Kownacki, P.; Marks, S.; Schlueter, R.

    1994-07-01

    Insertion devices for the Advanced Light Source (ALS) incorporate large numbers of permanent magnets which have a variety of magnetization orientation errors. These orientation errors can produce field errors which affect both the spectral brightness of the insertion devices and the storage ring electron beam dynamics. A perturbation study was carried out to quantify the effects of orientation errors acting in a hybrid magnetic structure. The results of this study were used to develop a multiple stage sorting algorithm which minimizes undesirable integrated field errors and essentially eliminates pole excitation errors. When applied to a measured magnet population for an existing insertion device, an order of magnitude reduction in integrated field errors was achieved while maintaining near zero pole excitation errors

  18. The characteristics of laser welded magnesium alloy using silver nanoparticles as insert material

    International Nuclear Information System (INIS)

    Ishak, M.; Maekawa, K.; Yamasaki, K.

    2012-01-01

    Highlights: ► Ag nanoparticles are used as insert material for welding Mg alloy with laser. ► We examine the microstructure and mechanical properties of welded Mg alloys. ► Nananoparticle promote grain refinement to the weld structure. ► Finer nanoparticle produces high weld efficiency and mechanical properties. - Abstract: This paper describes the characteristics of the laser welding of thin-sheet magnesium alloys using silver (Ag) nanoparticles as an insert material. The experiment was conducted using nanoparticles with 5 nm and 100 nm diameters that were welded with a Nd:YAG laser. The microstructure and mechanical properties of the specimens welded using inserts with different sizes of nanoparticles and without an insert material, were examined. Electron probe micro-analyzer (EPMA) analysis was conducted to confirm the existence of Ag in the welded area. The introduction of the Ag nanoparticle insert promoted large area of fine grain and broadened the acceptable range of scanning speed parameters compared to welds without an insert. Welds with 5 nm nanoparticles yielded the highest fracture load of up to 818 N while the lowest fracture load was found for weld specimens with 100 nm nanoparticles. This lower fracture load was due to larger voids and a smaller throat length, which contributed to a lower fracture load when using larger nanoparticles.

  19. A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

    Directory of Open Access Journals (Sweden)

    Tae Joon Choi

    2016-01-01

    Full Text Available Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

  20. Surprisingly facile CO2 insertion into cobalt alkoxide bonds: A theoretical investigation

    Directory of Open Access Journals (Sweden)

    Willem K. Offermans

    2015-07-01

    Full Text Available Exploiting carbon dioxide as co-monomer with epoxides in the production of polycarbonates is economically highly attractive. More effective catalysts for this reaction are intensively being sought. To promote better understanding of the catalytic pathways, this study uses density functional theory calculations to elucidate the reaction step of CO2 insertion into cobalt(III–alkoxide bonds, which is also the central step of metal catalysed carboxylation reactions. It was found that CO2 insertion into the cobalt(III–alkoxide bond of [(2-hydroxyethoxyCoIII(salen(L] complexes (salen = N,N”-bis(salicyliden-1,6-diaminophenyl is exothermic, whereby the exothermicity depends on the trans-ligand L. The more electron-donating this ligand is, the more exothermic the insertion step is. Interestingly, we found that the activation barrier decreases with increasing exothermicity of the CO2 insertion. Hereby, a linear Brønsted–Evans–Polanyi relationship was found between the activation energy and the reaction energy.

  1. Lysenin Toxin Membrane Insertion Is pH-Dependent but Independent of Neighboring Lysenins.

    Science.gov (United States)

    Munguira, Ignacio L B; Takahashi, Hirohide; Casuso, Ignacio; Scheuring, Simon

    2017-11-07

    Pore-forming toxins form a family of proteins that act as virulence factors of pathogenic bacteria, but similar proteins are found in all kingdoms of life, including the vertebrate immune system. They are secreted as soluble monomers that oligomerize on target membranes in the so-called prepore state; after activation, they insert into the membrane and adopt the pore state. Lysenin is a pore-forming toxin from the earthworm Eisenida foetida, of which both the soluble and membrane-inserted structures are solved. However, the activation and membrane-insertion mechanisms have remained elusive. Here, we used high-speed atomic force microscopy to directly visualize the membrane-insertion mechanism. Changing the environmental pH from pH 7.5 to below pH 6.0 favored membrane insertion. We detected a short α-helix in the soluble structure that comprised three glutamic acids (Glu92, Glu94, and Glu97) that we hypothesized may represent a pH-sensor (as in similar toxins, e.g., Listeriolysin). Mutant lysenin still can form pores, but mutating these glutamic acids to glutamines rendered the toxin pH-insensitive. On the other hand, toxins in the pore state did not favor insertion of neighboring prepores; indeed, pore insertion breaks the hexagonal ordered domains of prepores and separates from neighboring molecules in the membrane. pH-dependent activation of toxins may represent a common feature of pore-forming toxins. High-speed atomic force microscopy with single-molecule resolution at high temporal resolution and the possibility of exchanging buffers during the experiments presents itself as a unique tool for the study of toxin-state conversion. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M.

    2011-11-01

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm 3 in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  3. Outcomes of single- vs double-cuff artificial urinary sphincter insertion in low- and high-risk profile male patients with severe stress urinary incontinence.

    Science.gov (United States)

    Ahyai, Sascha A; Ludwig, Tim A; Dahlem, Roland; Soave, Armin; Rosenbaum, Clemens; Chun, Felix K-H; Fisch, Margit; Schmid, Marianne; Kluth, Luis A

    2016-10-01

    To evaluate continence and complication rates of bulbar single-cuff (SC) and distal bulbar double-cuff (DC) insertion in male patients with severe stress urinary incontinence (SUI) according to whether the men were considered low or high risk for unfavourable artificial urinary sphincter (AUS) outcomes. In all, 180 male patients who underwent AUS implantation between 2009 and 2013 were followed according to institutional standards. Patients with previous pelvic radiation therapy, open bulbar urethral or UI surgery ('high risk') underwent distal bulbar DC (123 patients) insertion, all others ('low risk') had proximal bulbar SC (57) insertion. Primary and secondary endpoints consisted of continence and complication rates. Kaplan-Meier analysis determined explantation-free survival, and Cox regression models assessed risk factors for persistent UI and explantation. The median follow-up was 24 months. Whereas there was no significant difference in pad usage/objective continence after SC vs DC insertion, superior rates of subjective/social continence and less persistent UI were reported by the patients with DC devices (all P ≤ 0.02). Overall, device explantation (erosion, infection or mechanical failure) occurred in 12.8% of patients. While early ( 0.05), DC patients had a 5.7-fold higher risk of device explantation during late follow-up (P = 0.02) and significantly shorter explantation-free survival (log-rank, P = 0.003). Distal bulbar DC insertion in patients with a 'high-risk' profile (previous pelvic radiation, urethral surgery) leads to similar objective continence, but higher explantation rates when compared with patients considered 'low risk' with proximal bulbar SCs. Randomised controlled trials comparing both devices will be needed to determine whether the higher explanations rates are attributable to the DC device or to underlying risk factors. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  4. Development of acceptance criteria and damage tolerance analyzes of the ductile iron insert

    International Nuclear Information System (INIS)

    Dillstroem, Peter; Alverlind, Lars; Andersson, Magnus

    2010-01-01

    SKB intends to qualify a test system for detection and sizing of defects deemed to be relevant to the ductile iron insert. In support of this qualification, a damage tolerance analysis indicating the current qualification targets, given assumed damage and failure modes. This report describes the damage tolerance analyzes of different types of defects that are considered relevant of the ductile iron insert. The results are reported separately for each test area (zone) and type of insert (BWRs and PWRs)

  5. SEQUENCING OF FLAX LIS-1 INSERTION SITE IN THE ALBIDUM GENOTYPE

    Directory of Open Access Journals (Sweden)

    Jana Žiarovská

    2012-12-01

    Full Text Available The paper presents a methodology of identifying the insertion site of LIS-1-1 (Linum Insertion Sequence 1 element in flax Albidum variety when growing under the in vitro combined with environmental stress conditions. Abiotic stress was induced by a reduced nutrient content in a growth medium. The LIS-1 insertion site amplification was reaLIS-1ed using the forward LIS-L: 5'-GGG CAG TTT AAC TGT AAC GAA - 3 'and revers LIS-R: 5'-GCT TGG ATT TAG ACT TGG CAA C - 3' primers by PCR. PCR product was sequenced by direct sequencing method to proove the nucleotide sequence for matching with database LIS-1 sequence. A comparison has been matched with the sequence of the amplified segment in the database for all nucleotides except the 11-position in the 5'-3 ' direction, where instead of the three adenine pair is a couple in the Albidum variety. Changes caused by mobile elements or insertion sequences result in common flax in variability that can be used for the purposes of development of effective marker identification or environment based markers development.

  6. Evaluation of the friction coefficient, the radial stress, and the damage work during needle insertions into agarose gels.

    Science.gov (United States)

    Urrea, Fabián A; Casanova, Fernando; Orozco, Gustavo A; García, José J

    2016-03-01

    Agarose hydrogels have been extensively used as a phantom material to mimic the mechanical behavior of soft biological tissues, e.g. in studies aimed to analyze needle insertions into the organs producing tissue damage. To better predict the radial stress and damage during needle insertions, this study was aimed to determine the friction coefficient between the material of commercial catheters and hydrogels. The friction coefficient, the tissue damage and the radial stress were evaluated at 0.2, 1.8, and 10mm/s velocities for 28, 30, and 32 gauge needles of outer diameters equal to 0.36, 0.31, and 0.23mm, respectively. Force measurements during needle insertions and retractions on agarose gel samples were used to analyze damage and radial stress. The static friction coefficient (0.295±0.056) was significantly higher than the dynamic (0.255±0.086). The static and dynamic friction coefficients were significantly smaller for the 0.2mm/s velocity compared to those for the other two velocities, and there was no significant difference between the friction coefficients for 1.8 and 10mm/s. Radial stress averages were 131.2±54.1, 248.3±64.2, and 804.9±164.3Pa for the insertion velocity of 0.2, 1.8, and 10mm/s, respectively. The radial stress presented a tendency to increase at higher insertion velocities and needle size, which is consistent with other studies. However, the damage work did not show to be a good predictor of tissue damage, which appears to be due to simplifications in the analytical model. Differently to other approaches, the method proposed here based on radial stress may be extended in future studies to quantity tissue damage in vivo along the entire needle track. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Theoretical study of helium insertion and diffusion in 3C-SiC

    International Nuclear Information System (INIS)

    Van Ginhoven, Renee M.; Chartier, Alain; Meis, Constantin; Weber, William J.; Rene Corrales, L.

    2006-01-01

    Insertion and diffusion of helium in cubic silicon carbide have been investigated by means of density functional theory. The method was assessed by calculating relevant properties for the perfect crystal along with point defect formation energies. Results are consistent with available theoretical and experimental data. Helium insertion energies were calculated to be lower for divacancy and silicon vacancy defects compared to the other mono-vacancies and interstitial sites considered. Migration barriers for helium were determined by using the nudged elastic band method. Calculated activation energies for migration in and around vacancies (silicon vacancy, carbon vacancy or divacancy) range from 0.6 to 1.0 eV. Activation energy for interstitial migration is calculated to be 2.5 eV. Those values are discussed and related to recent experimental activation energies for migration that range from 1.1 [P. Jung, J. Nucl. Mater. 191-194 (1992) 377] to 3.2 eV [E. Oliviero, A. van Veen, A.V. Fedorov, M.F. Beaufort, J.F. Bardot, Nucl. Instrum. Methods Phys. Res. B 186 (2002) 223; E. Oliviero, M.F. Beaufort, J.F. Bardot, A. van Veen, A.V. Fedorov, J. Appl. Phys. 93 (2003) 231], depending on the SiC samples used and on helium implantation conditions

  8. Mapping of a Leishmania major gene/locus that confers pentamidine resistance by deletion and insertion of transposable element

    Directory of Open Access Journals (Sweden)

    Coelho Adriano C.

    2004-01-01

    Full Text Available Pentamidine (PEN is an alternative compound to treat antimony-resistant leishmaniasis patients, which cellular target remains unclear. One approach to the identification of prospective targets is to identify genes able to mediate PEN resistance following overexpression. Starting from a genomic library of transfected parasites bearing a multicopy episomal cosmid vector containing wild-type Leishmania major DNA, we isolated one locus capable to render PEN resistance to wild type cells after DNA transfection. In order to map this Leishmania locus, cosmid insert was deleted by two successive sets of partial digestion with restriction enzymes, followed by transfection into wild type cells, overexpression, induction and functional tests in the presence of PEN. To determine the Leishmania gene related to PEN resistance, nucleotide sequencing experiments were done through insertion of the transposon Mariner element of Drosophila melanogaster (mosK into the deleted insert to work as primer island. Using general molecular techniques, we described here this method that permits a quickly identification of a functional gene facilitating nucleotide sequence experiments from large DNA fragments. Followed experiments revealed the presence of a P-Glycoprotein gene in this locus which role in Leishmania metabolism has now been analyzed.

  9. Conservative use of chest-tube insertion in children with pleural effusion.

    Science.gov (United States)

    Epaud, R; Aubertin, G; Larroquet, M; Pointe, H Ducou-le; Helardot, P; Clement, A; Fauroux, B

    2006-04-01

    The aim of this work was to evaluate the effect of a more conservative use of chest-tube insertion on the short-term and long-term outcome of pleural infection. Sixty-five patients with pleural infection, aged 1 month to 16 years were each treated according to one of the two protocols: classical management with chest-tube insertion (classical group, n = 33), or conservative use of chest-tube insertion (conservative group, n = 32), with drainage indicated only in the case of voluminous pleural effusion defined by a mediastinal shift and respiratory distress and/or an uncontrolled septic situation. The two groups were comparable with regard to age, baseline C-reactive protein (CRP) value and white blood cell counts, pleural thickness, identified bacteria, and antibiotic treatment. Chest-tube insertion was performed in 17 patients (52%) of the classical group compared to eight patients (25%) of the conservative group (P = 0.03). Duration of temperature above 39 degrees C was shorter in the conservative group (10 +/- 1 vs. 14 +/- 1 days, P = 0.01), as was the normalization of CRP (13 +/- 1 vs. 17 +/- 1 days, P = 0.03). Duration of hospitalization and intravenous (IV) antibiotherapy as well as the delay of chest-radiograph normalization was not significantly different between the two groups. A more conservative use of chest-tube insertion did not change short- and long-term outcome of the pleural infection in children. Drainage could be restricted to the most severely affected patients with pleural empyema causing a mediastinal shift and respiratory distress and/or presenting with an uncontrolled septic situation.

  10. Criticality safety of the ten-well insert for the pot dissolver

    International Nuclear Information System (INIS)

    Forstner, J.L.

    1982-05-01

    Nuclear safety for most fuels dissolved at SRP is ensured by some form of insert with a favorable geometry in a pot dissolver. A ten-well insert was designed which would permit an adequate charge of highly enriched U-Al alloy fuels of the MTR type. It can handle cylindrical fuel bundles up to 5 in. dia. Dependence on administrative control is reduced. 10 figures

  11. Modeling the Insertion Mechanics of Flexible Neural Probes Coated with Sacrificial Polymers for Optimizing Probe Design

    Directory of Open Access Journals (Sweden)

    Sagar Singh

    2016-03-01

    Full Text Available Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (<10% error. The ratio of the predicted buckling force-to-predicted insertion force, where a value greater than one would ideally be expected to result in successful insertion, was plotted against the actual success rate from experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the “safety factor”, as it indicated the degree to which the coating

  12. Impact of ultrasonography on central venous catheter insertion in intensive care

    International Nuclear Information System (INIS)

    Palepu, Gopal B; Deven, Juneja; Subrahmanyam, M; Mohan, S

    2009-01-01

    The insertion of central venous catheters (CVCs) is an integral part of the management of critically ill patients. We aimed to study the impact of ultrasonography (USG) on CVC insertion in intensive care. A prospective study of 450 patients requiring CVC in the intensive care unit (ICU) of a tertiary care hospital. The patients were randomized into two groups: to have CVC insertion with USG-guidance or with the anatomic landmark technique (ALT). Data were collected on patient demographics; operator experience; and method, site and side of insertion. Outcome measures included successful insertion of CVC, number of attempts needed and complications. Internal jugular vein (IJV) cannulation was successful in 177/194 patients (91.2%) using ALT and in 200/205 patients (97.6%) using USG guidance, a significant difference of 6.4% (P = 0.006). Using ALT, 72.7% of cannulations could be accomplished in the first attempt as compared with 84.4% with USG guidance (P = 0.004). The overall complication rate was 28/399 (7%), with 19 (9.8%) complications in the ALT group and 9 (4.4%) in the USG group (age-, sex-, and operator-adjusted OR = 0.35, 95% CI: 0.13–0.96; P = 0.03). For subclavian vein catheterization, the success rate was 26/28 (92.9%) in the ALT group and 17/17 (100%) in the USG group (P = 0.52). Using ALT, 71.4% cannulation could be accomplished in the first attempt as compared with 82.4% under USG guidance (P = 0.49). The overall complication rate was 6/45 (13.3%), with 4 (14.3%) complications in the ALT group and 2 (11.8%) in the USG group (P > 0.99). Real-time USG guidance improves success rates, reduces the number of attempts and decreases the complications associated with CVC insertion, especially for the IJV, and should become the standard of care in intensive care

  13. TF insert experiment log book. 2nd Experiment of CS model coil

    International Nuclear Information System (INIS)

    Sugimoto, Makoto; Isono, Takaaki; Matsui, Kunihiro

    2001-12-01

    The cool down of CS model coil and TF insert was started on August 20, 2001. It took almost one month and immediately started coil charge since September 17, 2001. The charge test of TF insert and CS model coil was completed on October 19, 2001. In this campaign, total shot numbers were 88 and the size of the data file in the DAS (Data Acquisition System) was about 4 GB. This report is a database that consists of the log list and the log sheets of every shot. This is an experiment logbook for 2nd experiment of CS model coil and TF insert for charge test. (author)

  14. Ocular lens availability of glutathione from collagen inserts for protection of eye from radiation

    International Nuclear Information System (INIS)

    Omer, S.A.

    2003-01-01

    Full text: Ocular inserts of glutathione ( G ) were prepared using 1 % collagen solution containing free G ,liposomal G and liposomal G with Concanavalin A ,a specific targeting agent of G to ocular lens. These inserts have to be sterilized for in-vivo ophthalmic application by exposure to U V radiation for 2 hr. using dry ice and acetone for protection of G from thermal degradation. In vitro release characteristics of G (17.0 μ mole) from the prepared inserts were investigated at 37deg C in phosphate buffer pH 7.4 . The results of release data showed that the release of G from inserts were arranged in the following order, free G, liposomal G with or without Concanavalin A. The extent of uptake of G from the collagen inserts by rabbit cornea was also tested. The results of ocular lens availability of G from collagen inserts revealed that a highly significant increase in the uptake of G by ocular lenses,where the percentages drug uptake from the applied doses at T max were 1.12% (p(0.05), 2.12% (p(0.01) and 3.4% (p(0.001) in case of using collagen inserts containing free G, liposomal G and liposomal G with Concanavalin A respectively. That is to say,lipid nature of liposomes together with Concanavlin A improved the penetration of the entrapped hydrophilic G through corneal barrier to the ocular lenses

  15. Insertion of pedagogical activities mediated by ICT in literacy

    Directory of Open Access Journals (Sweden)

    Lúcia Margarete Santos da Costa

    2016-12-01

    Full Text Available This article is cut out of a research dissertation entitled "Educational activities insertion mediated by ICT literacy. This study aimed to implement such activities promoting the integration of ICT as an aid in the literacy process in a primary education school (EF of Santa Maria and had as participants the students of the 3rd year. In this survey we present results of the activities of insertion mediated by E-book technology. Therefore we sought theoretical foundation in authors like Ferreira and Teberoscky (1999, Freire (1989, 1996, Mendonça and Mendonça (2008 and other authors who contribute to the theme. The methodology used was action research that enables the construction of knowledge through practice, reflection-action and intervention in school reality. This study is linked to the line of research "Educational Technologies in Management Network", Federal University of Santa Maria. The results showed that the ICT e-book inserted in literacy contributed significantly to the advancement of learning reading, writing and the development of various skills as well as to build the autonomy of collaboration and cooperation among students considering the teacher as an important articulator and mediator interactions.

  16. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao

    2016-10-14

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively in-chain anhydride groups are formed by terpolymerization with carbic anhydride. Combined experimental and theoretical DFT studies reveal the key for this direct approach to telechelics to be a match of the comonomers’ different electronics and bulk. Identified essential features of the comonomer are that it is an electron-rich olefin that forms an insertion product stabilized by an additional interaction, namely a π–η3 interaction for the case of VF.

  17. A statistical approach designed for finding mathematically defined repeats in shotgun data and determining the length distribution of clone-inserts

    DEFF Research Database (Denmark)

    Zhong, Lan; Zhang, Kunlin; Huang, Xiangang

    2003-01-01

    that repeats of different copy number have different probabilities of appearance in shotgun data, so based on this principle, we constructed a statistical model and inferred criteria for mathematically defined repeats (MDRs) at different shotgun coverages. According to these criteria, we developed software...... MDRmasker to identify and mask MDRs in shotgun data. With repeats masked prior to assembly, the speed of assembly was increased with lower error probability. In addition, clone-insert size affect the accuracy of repeat assembly and scaffold construction, we also designed length distribution of clone...

  18. Cochlear Dummy Electrodes for Insertion Training and Research Purposes: Fabrication, Mechanical Characterization, and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Jan-Philipp Kobler

    2015-01-01

    Full Text Available To develop skills sufficient for hearing preservation cochlear implant surgery, surgeons need to perform several electrode insertion trials in ex vivo temporal bones, thereby consuming relatively expensive electrode carriers. The objectives of this study were to evaluate the insertion characteristics of cochlear electrodes in a plastic scala tympani model and to fabricate radio opaque polymer filament dummy electrodes of equivalent mechanical properties. In addition, this study should aid the design and development of new cochlear electrodes. Automated insertion force measurement is a new technique to reproducibly analyze and evaluate the insertion dynamics and mechanical characteristics of an electrode. Mechanical properties of MED-EL’s FLEX28, FLEX24, and FLEX20 electrodes were assessed with the help of an automated insertion tool. Statistical analysis of the overall mechanical behavior of the electrodes and factors influencing the insertion force are discussed. Radio opaque dummy electrodes of comparable characteristics were fabricated based on insertion force measurements. The platinum-iridium wires were replaced by polymer filament to provide sufficient stiffness to the electrodes and to eradicate the metallic artifacts in X-ray and computed tomography (CT images. These low-cost dummy electrodes are cheap alternatives for surgical training and for in vitro, ex vivo, and in vivo research purposes.

  19. Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol.

    Science.gov (United States)

    Carr, Peter J; Rippey, James C R; Cooke, Marie L; Bharat, Chrianna; Murray, Kevin; Higgins, Niall S; Foale, Aileen; Rickard, Claire M

    2016-02-11

    Peripheral intravenous cannula (PIVC) insertion is one of the most common clinical interventions performed in emergency care worldwide. However, factors associated with successful PIVC placement and maintenance are not well understood. This study seeks to determine the predictors of first time PIVC insertion success in emergency department (ED) and identify the rationale for removal of the ED inserted PIVC in patients admitted to the hospital ward. Reducing failed insertion attempts and improving peripheral intravenous cannulation practice could lead to better staff and patient experiences, as well as improving hospital efficiency. We propose an observational cohort study of PIVC insertions in a patient population presenting to ED, with follow-up observation of the PIVC in subsequent admissions to the hospital ward. We will collect specific PIVC observational data such as; clinician factors, patient factors, device information and clinical practice variables. Trained researchers will gather ED PIVC insertion data to identify predictors of insertion success. In those admitted from the ED, we will determine the dwell time of the ED-inserted PIVC. Multivariate regression analyses will be used to identify factors associated with insertions success and PIVC failure and standard statistical validation techniques will be used to create and assess the effectiveness of a clinical predication rule. The findings of our study will provide new evidence to improve insertion success rates in the ED setting and identify strategies to reduce premature device failure for patients admitted to hospital wards. Results will unravel a complexity of factors that contribute to unsuccessful PIVC attempts such as patient and clinician factors along with the products, technologies and infusates used. ACTRN12615000588594; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Metal stents insertion in the treatment of the patients with benign oesophageal strictures

    International Nuclear Information System (INIS)

    Valek, V.; Benda, K.; Hrobar, P.; Mrazova, J.; Prasek, J.; Vomela, J.; Muenzova, H.; Hep, A.; Stefl, M.

    1996-01-01

    Between October 1993 and June 1995 the authors inserted in the Department of Radiology in University Hospital Bohunice in 16 of their patients with benign stenosis of the oesophagus an expandable metals stent. the aetiology of the stenosis was long-term reflux oesophagitis (6x), postoperative benign stenosis in anastomosis (3x), corrosive structure (2x), epidermolysis bulosa oesophagi (2x) and post-radiation structure (1x). In two patients the aetiology of the stenosis was unknown. All the patients suffered at the the of the stent insertion from marked dysphagia (stage 3 and/or 4). The indication for oesophageal stent implantation was always carefully considered by an interdisciplinary indication committee. Before the stent insertion all the stenoses have been repeatedly unsuccessfully dilated with balloon dilatation catheter. In total, 25 stents were used. In seven patients were inserted more as one stent. The intervention itself was preceded by a double contrast X-ray examination of oesophagus, oesophagoscopy with biopsy to verify the stricture aetiology, computed tomography and endosonography. No complications associated with the intervention have been encountered and stent insertions have always been well tolerated. (authors). 1 tab., 3 figs., 9 refs

  1. Evaluation of feasibility of tungsten/oxide dispersion strengthened steel bonding with vanadium insert

    International Nuclear Information System (INIS)

    Noto, Hiroyuki; Kimura, Akihiko; Kurishita, Hiroaki; Matsuo, Satoru; Nogami, Shuhei

    2013-01-01

    A diffusion bonding (DB) technique to reduce thermal expansion coefficient mismatch between tungsten (W) and oxide dispersion strengthened ferritic steel (ODS-FS) was developed by applying a vanadium (V) alloy as an insert material. In order to suppress σ phase precipitation at the interface, DB of ODS-FS and V-4Cr-4Ti was carried out by introducing a Ti insert as a diffusion barrier between V-4Cr-4Ti and ODS-FS, and examined feasibility of W/V/Ti/ODS-FS joint for application to fusion reactor components by comparing the three-point bending strength and microstructure between the joints with and without a Ti diffusion barrier layer. It is shown that the fracture strength of the joint without a Ti insert was decreased by 25% after aging at 700°C for 100 h, but that with a Ti insert shows no change after the aging treatment up to 1000 h. The result indicates that the introduction of a Ti insert leads to the prevention of the formation of σ phase during aging and resultant control of the degradation of the bonding strength. (author)

  2. Genome-Wide Estimates of Transposable Element Insertion and Deletion Rates in Drosophila Melanogaster

    Science.gov (United States)

    Adrion, Jeffrey R.; Song, Michael J.; Schrider, Daniel R.; Hahn, Matthew W.

    2017-01-01

    Abstract Knowing the rate at which transposable elements (TEs) insert and delete is critical for understanding their role in genome evolution. We estimated spontaneous rates of insertion and deletion for all known, active TE superfamilies present in a set of Drosophila melanogaster mutation-accumulation (MA) lines using whole genome sequence data. Our results demonstrate that TE insertions far outpace TE deletions in D. melanogaster. We found a significant effect of background genotype on TE activity, with higher rates of insertions in one MA line. We also found significant rate heterogeneity between the chromosomes, with both insertion and deletion rates elevated on the X relative to the autosomes. Further, we identified significant associations between TE activity and chromatin state, and tested for associations between TE activity and other features of the local genomic environment such as TE content, exon content, GC content, and recombination rate. Our results provide the most detailed assessment of TE mobility in any organism to date, and provide a useful benchmark for both addressing theoretical predictions of TE dynamics and for exploring large-scale patterns of TE movement in D. melanogaster and other species. PMID:28338986

  3. Effect of Tension and Curvature of Skin on Insertion Characteristics of Microneedle Array

    Science.gov (United States)

    Tachikawa, Hiroto; Takano, Naoki; Nishiyabu, Kazuaki; Miki, Norihisa; Ami, Yoshimichi

    Recent MEMS (micro electro mechanical system) fabrication techniques have made it possible to produce painless microneedles precisely enough to be inserted into epidermis layer penetrating the stratum corneum of human skin. This paper presents a testing procedure to evaluate the insertion characteristics of microneedle array using cultured human skin considering the tension and the curvature. First, the biaxial strain applied to the cultured human skin was measured by optical technique with image processing. It was found that almost constant strain could be successfully given within a certain area and that error factors in the experiment except the thickness variation of the cultured skin were negligible. Next, using a microneedle square array for brain machine interface (BMI) application, the effects of biaxial tension and the curvature on insertion characteristics were discussed. Within the above mentioned area with high strain, the needles were successfully inserted.

  4. Electromagnetic analysis, structural integrity and progress on mechanical design of the ITER ferromagnetic insert

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, M. [Mitsubishi Heavy Industries, Ltd., 1-1 Wadasaki-cho 1-chome, Hyogo-ku, Kobe 652-8585 (Japan)], E-mail: masaaki_morimoto@maia.eonet.ne.jp; Ioki, K.; Terasawa, A.; Utin, Yu.; Barabash, V.; Gribov, Y. [ITER Organization, 13108 St. Paul lez Durance (France)

    2009-12-15

    Ferromagnetic material is used to reduce the toroidal field ripple in JFT-2M and JT-60U . In ITER, since the ferromagnetic material is inserted in the space between the double walls of ITER Vacuum Vessel (VV), it is called 'ferromagnetic inserts'. Suitable material is selected to satisfy the design requirements of ITER. The proper location and amount of the ferromagnetic inserts are optimized with the goal of reduction of the toroidal field ripple. The ferromagnetic inserts are designed to minimize electromagnetic forces acting on them. The electromagnetic forces have been calculated with the latest disruption scenarios. Magnetization forces due to magnetic fields have also been calculated. Structural integrity has been validated by a structural analysis.

  5. Determination of the dose and dose distribution in radiation-linked polyolefins

    International Nuclear Information System (INIS)

    Andress, B.; Fischer, P.; Repp, H.H.; Roehl, P.

    1984-01-01

    The method serves the determination of the radiation dose and dose distribution in polyolefins cross-linked by electron beams; the cross-linking takes place in the presence of an additive which is inserted in the polyolefin by radiation. After the cross-linking the fraction of the additive which is not inserted will be extracted from the polyolefin and afterwards the total extinction of the polyolefin will be determined by photometry. This process allows in particular the determination of the quality of the irradiation conditions for the electron-beam cross-linking of medium-voltage cables insulated by polyolefins. (orig.) [de

  6. Single phase and two-phase flow pressure losses through restrictions, expansions and inserts

    International Nuclear Information System (INIS)

    Glenat, P.; Solignac, P.

    1984-11-01

    We give a selection of methods to predict pressure losses through retrictions, expansions and inserts. In single phase flow, we give the classical method based on the one-dimensional momentum and mass balances. In two-phase flow, we propose the method given by Harshe et al. and an empirical approach suggested by Chisholm. We notice the distinction between long and short inserts depends upon wether or not the vena contracta lies within insert. Finally, we propose three correlations to calculate void fraction through the singularities which have been considered [fr

  7. Net-bottom Cage Inserts for Water Bird Casualties

    Directory of Open Access Journals (Sweden)

    Jackie Belle

    2017-10-01

    Full Text Available My Bright Idea is a net-bottomed cage insert, which is used to support pelagic avian casualties. The idea was designed and modified by the International Bird Rescue in California (Bird Rescue.

  8. Angiotensin converting enzyme insertion/deletion polymorphism: association with ethnic origin.

    Science.gov (United States)

    Barley, J; Blackwood, A; Carter, N D; Crews, D E; Cruickshank, J K; Jeffery, S; Ogunlesi, A O; Sagnella, G A

    1994-08-01

    To determine the distribution of the insertion/deletion (I/D) polymorphism of the angiotensin converting enzyme (ACE) gene in several ethnic groups: Caucasian Europeans, Black Nigerians, Samoan Polynesians and Yanomami Indians. The ratio of the frequencies of the II, ID and DD genotypes were 1:2:1 in the Europeans, but there was a tendency towards a higher frequency of the D allele in the Nigerians. In contrast, the Samoans and the Yanomami Indians displayed a much higher frequency of the I allele than of the D allele. The relationship between ACE genotype and disease in these latter groups is still not known, but the present results clearly suggest that ethnic origin should be carefully considered in the increasing number of studies on the association between I/D ACE genotype and disease aetiology.

  9. Nasal inserts containing ondansetron hydrochloride based on Chitosan–gellan gum polyelectrolyte complex: In vitro–in vivo studies

    Energy Technology Data Exchange (ETDEWEB)

    Sonje, Ashish G.; Mahajan, Hitendra S., E-mail: hsmahajan@rediffmail.com

    2016-07-01

    The aim of this study was the production of ondansetron hydrochloride loaded lyophilized insert for nasal delivery. The nasal insert was prepared by the lyophilisation technique using Chitosan–gellan gum polyelectrolyte complex as the polymer matrix. The ondansetron loaded inserts were evaluated with respect to water uptake, bioadhesion, drug release kinetic study, ex vivo permeation study, and in vivo study. Lyophilised nasal inserts were characterized by differential scanning calorimetry, scanning electron microscopy and X-ray diffraction study. Scanning electron microscopy confirmed the porous sponge like structure of inserts whereas release kinetic model revealed that drug release followed non-fickian case II diffusion. The nasal delivery showed improved bioavailability as compared to oral delivery. In conclusion, the ondansetron containing nasal inserts based on Chitosan–gellan gum complex with potential muco-adhesive potential is suitable for nasal delivery. - Highlights: • Chitosan–gellan gum polyelectrolyte complex based inserts have been prepared. • The synthesized polymer complex demonstrated important insert properties. • No toxicity was observed toward nasal mucosa. • In vivo study demonstrates the enhancement of bioavailability.

  10. Evolution of Surface Texture and Cracks During Injection Molding of Fiber-Reinforced, Additively-Manufactured, Injection Molding Inserts

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Mischkot, Michael; Pedersen, David Bue

    2016-01-01

    This paper investigates the lifetime and surfacedeterioration of additively-manufactured, injection-moulding inserts. The inserts were produced using digital light processing and were reinforcedwith oriented short carbon fibers. Theinserts were used during injection molding oflow-density polyethy......This paper investigates the lifetime and surfacedeterioration of additively-manufactured, injection-moulding inserts. The inserts were produced using digital light processing and were reinforcedwith oriented short carbon fibers. Theinserts were used during injection molding oflow......-density polyethylene until their failure. The molded products were used to analyse the development of the surface roughness and wear. By enhancing the lifetime of injection-molding inserts,this work contributes to the establishment of additively manufactured inserts in pilot production....

  11. Amino Acid Insertion Frequencies Arising from Photoproducts Generated Using Aliphatic Diazirines

    Science.gov (United States)

    Ziemianowicz, Daniel S.; Bomgarden, Ryan; Etienne, Chris; Schriemer, David C.

    2017-10-01

    Mapping proteins with chemical reagents and mass spectrometry can generate a measure of accessible surface area, which in turn can be used to support the modeling and refinement of protein structures. Photolytically generated carbenes are a promising class of reagent for this purpose. Substituent effects appear to influence surface mapping properties, allowing for a useful measure of design control. However, to use carbene labeling data in a quantitative manner for modeling activities, we require a better understanding of their inherent amino acid reactivity, so that incorporation data can be normalized. The current study presents an analysis of the amino acid insertion frequency of aliphatic carbenes generated by the photolysis of three different diazirines: 3,3'-azibutyl-1-ammonium, 3,3'-azibutan-1-ol, and 4,4'-azipentan-1-oate. Leveraging an improved photolysis system for single-shot labeling of sub-microliter frozen samples, we used EThCD to localize insertion products in a large population of labeled peptides. Counting statistics were drawn from data-dependent LC-MS2 experiments and used to estimate the frequencies of insertion as a function of amino acid. We observed labeling of all 20 amino acids over a remarkably narrow range of insertion frequencies. However, the nature of the substituent could influence relative insertion frequencies, within a general preference for larger polar amino acids. We confirm a large (6-fold) increase in labeling yield when carbenes were photogenerated in the solid phase (77 K) relative to the liquid phase (293 K), and we suggest that carbene labeling should always be conducted in the frozen state to avoid information loss in surface mapping experiments. [Figure not available: see fulltext.

  12. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report.

    Science.gov (United States)

    Mulier, Michiel; Pastrav, Cesar; Van der Perre, Georges

    2008-01-01

    Defining the stem insertion end point during total hip replacement still relies on the surgeon's feeling. When a custom-made stem prosthesis with an optimal fit into the femoral canal is used, the risk of per-operative fractures is even greater than with standard prostheses. Vibration analysis is used in other clinical settings and has been tested as a means to detect optimal stem insertion in the laboratory. The first per-operative use of vibration analysis during non-cemented custom-made stem insertion in 30 patients is reported here. Thirty patients eligible for total hip replacement with uncemented stem prosthesis were included. The neck of the stem was connected with a shaker that emitted white noise as excitation signal and an impedance head that measured the frequency response. The response signal was sent to a computer that analyzed the frequency response function after each insertion phase. A technician present in the operating theatre but outside the laminated airflow provided feed-back to the surgeon. The correlation index between the frequency response function measured during the last two insertion hammering sessions was >0.99 in 86.7% of the cases. In four cases the surgeon stopped the insertion procedure because of a perceived risk of fracture. Two special cases illustrating the potential benefit of per-operative vibration analysis are described. The results of intra-operative vibration analysis indicate that this technique may be a useful tool assisting the orthopaedic surgeon in defining the insertion endpoint of the stem. The development of a more user-friendly device is therefore warranted.

  13. Copy number determination of genetically-modified hematopoietic stem cells.

    Science.gov (United States)

    Schuesler, Todd; Reeves, Lilith; Kalle, Christof von; Grassman, Elke

    2009-01-01

    Human gene transfer with gammaretroviral, murine leukemia virus (MLV) based vectors has been shown to effectively insert and express transgene sequences at a level of therapeutic benefit. However, there are numerous reports of disruption of the normal cellular processes caused by the viral insertion, even of replication deficient gammaretroviral vectors. Current gammaretroviral and lentiviral vectors do not control the site of insertion into the genome, hence, the possibility of disruption of the target cell genome. Risk related to viral insertions is linked to the number of insertions of the transgene into the cellular DNA, as has been demonstrated for replication competent and replication deficient retroviruses in experiments. At high number of insertions per cell, cell transformation due to vector induced activation of proto-oncogenes is more likely to occur, in particular since more than one transforming event is needed for oncogenesis. Thus, determination of the vector copy number in bulk transduced populations, individual colony forming units, and tissue from the recipient of the transduced cells is an increasingly important safety assay and has become a standard, though not straightforward assay, since the inception of quantitative PCR.

  14. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    Directory of Open Access Journals (Sweden)

    Narjis AL Saif

    2015-01-01

    Full Text Available Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  15. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  16. A model for electrochemical insertion limited by a phase transition process - eilpt

    Directory of Open Access Journals (Sweden)

    Adhoum N.

    2003-01-01

    Full Text Available This paper deals with electrochemical insertion into a cathodic material. New results on modeling of the influence of a solid phase transformation on the shape of voltamograms are presented. The original experiments concern the insertion of sodium into carbon during the cathodic reduction of molten NaF at 1020 °C, but in the present manuscript emphasis on the theoretical aspects of the work is put. Phase transformations during electrochemical insertion are taken into account, with various values for parameters such as the thermodynamic biphase equilibrium potential, the compared diffusion and phase transformation kinetics, and the electrode thickness. The voltamograms calculated present very specific features; some of them have already been observed experimentally in literature.

  17. Genotyping of the 19-bp insertion/deletion polymorphism in the 5' flank of beta-hydroxylase gene by dissociation analysis of allele-specific PCR products

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Berg; Werge, Thomas

    2005-01-01

    The 19-bp insertion/deletion polymorphism in the 5' flank of the dopamine beta-hydroxylase (DBH) gene has been associated with psychiatric disorders. We have developed a simple, reliable and inexpensive closed-tube assay for genotyping of this polymorphism based upon T(m) determination of amplified...... and a conventional approach based upon agarose gel electrophoresis of amplified fragments revealed complete concordance between the two procedures. The insights obtained in this study may be utilized to develop assays based upon dissociation analysis of PCR products for genotyping of other insertion...

  18. Apparatus for housing radiation measuring material housed in a plastic insert

    International Nuclear Information System (INIS)

    Collica, C.; Epifano, L.; Farella, R.

    1977-01-01

    An apparatus for housing radiation measuring material is described. First and second members having generally flat and opposing surfaces are provided, the members being joined with their surfaces in spaced relationship. The first surface has a plurality of circular recessed areas. The second surface has a plurality of recessed areas positionally aligned with the plurality of recessed areas in the first surface. A generally flat insert member is provided, the insert member proportioned to removably fit between the surfaces. The insert member has a plurality of circular apertures positionally aligned with the recessed areas, the apertures being adapted to removably receive and retain dosimetry discs. The recessed areas in the first and second surfaces are adapted to removably receive filter elements. The apparatus can be used for housing many of the various types of commercially available radiation measuring material

  19. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    International Nuclear Information System (INIS)

    Harris, S.P.

    1997-01-01

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock-up Facility using 3 ml inserts and 15 ml peanut vials. A number of the insert samples were analyzed by Cold Chem and compared with full peanut vial samples analyzed by the current methods. The remaining inserts were analyzed by

  20. EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.

    Science.gov (United States)

    Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido

    2010-01-01

    To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.

  1. Short communication: Evaluation of vaginal discharge following treatment with a progesterone insert.

    Science.gov (United States)

    Fischer-Tenhagen, C; von Krueger, X; Heuwieser, W

    2012-08-01

    Yellowish discharge after application of intravaginal progesterone releasing inserts is frequently observed in cows. The objective of this study was to compare the bacteriological contamination of the vagina and uterus before and after a treatment with a progesterone insert in heifers. Forty-two Holstein heifers received a progesterone releasing insert [Eazi-Breed controlled internal drug release (CIDR) insert; Pfizer Animal Health, Berlin, Germany] for 7d. The protruding tail had been removed from half of the inserts (no tail group: n=21; tail group: n=21). Nine heifers from the tail group lost the insert within the 7-d treatment interval and were excluded. Heifers identified in estrus were artificially inseminated on d 9 or 10. Vaginal discharge was scored on a 4-point scale [vaginal discharge score (VDS) 0 to 3] and vaginal swabs were taken for bacteriological examination on d 0 and 7 and the day of artificial insemination (AI). Furthermore, cytological and bacteriological samples were obtained from the uterus on d 7 and the day of AI. On d 0, coliforms and Streptococcus spp. were found in vaginal swabs of 21 heifers (64%). On d 7, all heifers showed purulent vaginal discharge (VDS 2 to 3). The VDS was higher in the tail group compared with the no tail group. Arcanobacterium pyogenes, coliforms, and Streptococcus spp. were isolated from the vaginal swabs in 32 of 33 (96%) heifers on d 7. On the day of AI, VDS had improved to 0 or 1 in 96% of the heifers. However, A. pyogenes, coliforms, and Streptococcus spp. were still isolated in 17 of 33 (53%) heifers from the vagina and in 32 of 33 (96%) heifers from the endometrium. Endometrial cytology revealed polymorphonuclear neutrophils (PMN) in 11 heifers (6 to 32% PMN). Five samples exceeded the threshold of 5% PMN, and 2 samples exceeded the 10% PMN threshold, indicative of subclinical endometritis. In conclusion, pyogenic bacteria were found in the vagina and uterus on d 7 and the day of AI after intravaginal

  2. Comparison of four techniques of nasogastric tube insertion in anaesthetised, intubated patients: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Mohan Chandra Mandal

    2014-01-01

    Full Text Available Background and Aims: Insertion of nasogastric tubes (NGTs in anaesthetised, intubated patients with a conventional method is sometimes difficult. Different techniques of NGT insertion have been tried with varying degree of success. The aim of this prospective, randomised, open-label study was to evaluate three modified techniques of NGT insertion comparing with the conventional method in respect of success rate, time taken for insertion and the adverse events. Methods: In the operation theatre of general surgery, the patients were randomly allocated into four groups: Group C (control group, n = 54, Group W (ureteral guide wire group, n = 54, Group F (neck flexion with lateral pressure, n = 54 and Group R (reverse Sellick′s manoeuvre, n = 54. The number of attempts for successful NGT insertion, time taken for insertion and adverse events were noted. Results: All the three modified techniques were found more successful than the conventional method on the first attempt. The least time taken for insertion was noted in the reverse Sellick′s method. However, on intergroup analysis, neck flexion and reverse Sellick′s methods were comparable but significantly faster than the other two methods with respect to time taken for insertion. Conclusion: Reverse Sellick′s manoeuver, neck flexion with lateral neck pressure and guide wire-assisted techniques are all better alternatives to the conventional method for successful, quick and reliable NGT insertion with permissible adverse events in anaesthetised, intubated adult patients. Further studies after eliminating major limitations of the present study are warranted to establish the superiority of any one of these modified techniques.

  3. Human Retrotransposon Insertion Polymorphisms Are Associated with Health and Disease via Gene Regulatory Phenotypes

    Directory of Open Access Journals (Sweden)

    Lu Wang

    2017-08-01

    Full Text Available The human genome hosts several active families of transposable elements (TEs, including the Alu, LINE-1, and SVA retrotransposons that are mobilized via reverse transcription of RNA intermediates. We evaluated how insertion polymorphisms generated by human retrotransposon activity may be related to common health and disease phenotypes that have been previously interrogated through genome-wide association studies (GWAS. To address this question, we performed a genome-wide screen for retrotransposon polymorphism disease associations that are linked to TE induced gene regulatory changes. Our screen first identified polymorphic retrotransposon insertions found in linkage disequilibrium (LD with single nucleotide polymorphisms that were previously associated with common complex diseases by GWAS. We further narrowed this set of candidate disease associated retrotransposon polymorphisms by identifying insertions that are located within tissue-specific enhancer elements. We then performed expression quantitative trait loci analysis on the remaining set of candidates in order to identify polymorphic retrotransposon insertions that are associated with gene expression changes in B-cells of the human immune system. This progressive and stringent screen yielded a list of six retrotransposon insertions as the strongest candidates for TE polymorphisms that lead to disease via enhancer-mediated changes in gene regulation. For example, we found an SVA insertion within a cell-type specific enhancer located in the second intron of the B4GALT1 gene. B4GALT1 encodes a glycosyltransferase that functions in the glycosylation of the Immunoglobulin G (IgG antibody in such a way as to convert its activity from pro- to anti-inflammatory. The disruption of the B4GALT1 enhancer by the SVA insertion is associated with down-regulation of the gene in B-cells, which would serve to keep the IgG molecule in a pro-inflammatory state. Consistent with this idea, the B4GALT1 enhancer

  4. Formulation and Evaluation of Chitosan-Chondroitin Sulphate Based Nasal Inserts for Zolmitriptan

    Directory of Open Access Journals (Sweden)

    Kirandeep Kaur

    2013-01-01

    Full Text Available Bioadhesive nasal dosage forms are an attractive method for overcoming rapid mucociliary clearance transport in the nose and for delivering the drug directly to brain. The present study was designed to formulate chondroitin sulphate (CS and chitosan (CH nasal inserts employing zolmitriptan, an antimigraine drug. The interpolymer complexes (IPC formed between –COO− and – groups of CS and group of CH were characterized by infrared spectroscopy (IR, differential scanning analysis (DSC, and zeta potential studies. The unloaded and loaded nasal inserts were evaluated for water uptake studies, and bioadhesive strength studies, scanning electron microscopic studies (SEM. The in vitro drug release and in situ permeation studies were carried out on loaded nasal inserts. The DSC and IR studies confirmed the formation of a complex between the two polymers. The results indicated that the formulation F1 (CH : CS; 30 : 70 was demonstrating the highest bioadhesive strength and zeta potential. The presence of porous structure in the nasal inserts was confirmed by the SEM analysis. Further, in vitro and in situ release studies demonstrated that formulations F9 and F11 (drug : polymer; 1 : 10 were releasing 90% and 98% zolmitriptan over a period of 8 h. It can be concluded that nasal inserts formulated from chitosan-chondroitin sulphate (CH-CS interpolymer complex (IPC can be used for delivery of antimigraine drug to brain.

  5. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    The last ISABELLE workshop of the summer 1976 series, which was held at Brookhaven, August 16-20, focused on the design and utilization of the experimental insertions. The goals of the workshop, which were somewhat more general than might be suggested by the title, are: (1) review the ISABELLE proposal from the point of view of experimental use; (2) contribute useful information on the ''open questions'' in the ISABELLE design; (3) develop data for experimental equipment and operating cost estimates; and (4) project a first approximation to ISABELLE operating modes

  6. Extension of knee immobilization delays recovery of histological damages in the anterior cruciate ligament insertion and articular cartilage in rabbits.

    Science.gov (United States)

    Mutsuzaki, Hirotaka; Nakajima, Hiromi; Sakane, Masataka

    2018-01-01

    [Purpose] To investigate the influence of knee immobilization period on recovery of histological damages in the anterior cruciate ligament (ACL) insertion and articular cartilage in rabbits. This knowledge is important for determining the appropriate rehabilitation approach for patients with ligament injuries, fracture, disuse atrophy, and degenerative joint disease. [Materials and Methods] Forty-eight male Japanese white rabbits were divided equally into the remobilization and control groups. The remobilization group had the right knee surgically immobilized, and was divided equally into four subgroups according to the duration of immobilization (1, 2, 4 and 8 weeks). After the immobilization was removed, the rabbits moved freely for 8 weeks. The control group underwent sham operation and followed the same time course as the remobilization group. The chondrocyte apoptosis rate and chondrocyte proliferation rate in the ACL insertion and articular cartilage were analyzed after remobilization. [Results] In the ACL insertion, the remobilization group had a higher chondrocyte apoptosis rate than the control group after 8 weeks of immobilization, and a lower chondrocyte proliferation rate than the control group after 4 and 8 weeks of immobilization. In the articular cartilage, the remobilization group had a lower chondrocyte proliferation rate than the control group after 8 weeks of immobilization. After 8 weeks of remobilization, the ACL insertion and articular cartilage are not completely recovered after 4 and 8 weeks of immobilization, respectively. [Conclusion] Our results suggest that 8 weeks of remobilization will result in recovery of the ACL insertion after 2 weeks of knee immobilization, and recovery of the articular cartilage after 4 weeks of knee immobilization. If 8 weeks of immobilization occurs, a remobilization duration of more than 8 weeks may be necessary.

  7. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Via Golgi 40, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman [Mediso Medical Imaging Systems, Alsotorokvesz 14, H-1022 Budapest (Hungary); Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto [Fondazione Bruno Kessler (FBK), Via Sommarive, 18, 38123 Trento (Italy); Rieger, Jan [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Niendorf, Thoralf [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Berlin Ultrahigh Field Facility (B.UniversityF.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin (Germany)

    2014-07-29

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  8. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    International Nuclear Information System (INIS)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo; Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman; Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto; Rieger, Jan; Niendorf, Thoralf

    2014-01-01

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  9. Genome-scale metabolic network validation of Shewanella oneidensis using transposon insertion frequency analysis.

    Directory of Open Access Journals (Sweden)

    Hong Yang

    2014-09-01

    Full Text Available Transposon mutagenesis, in combination with parallel sequencing, is becoming a powerful tool for en-masse mutant analysis. A probability generating function was used to explain observed miniHimar transposon insertion patterns, and gene essentiality calls were made by transposon insertion frequency analysis (TIFA. TIFA incorporated the observed genome and sequence motif bias of the miniHimar transposon. The gene essentiality calls were compared to: 1 previous genome-wide direct gene-essentiality assignments; and, 2 flux balance analysis (FBA predictions from an existing genome-scale metabolic model of Shewanella oneidensis MR-1. A three-way comparison between FBA, TIFA, and the direct essentiality calls was made to validate the TIFA approach. The refinement in the interpretation of observed transposon insertions demonstrated that genes without insertions are not necessarily essential, and that genes that contain insertions are not always nonessential. The TIFA calls were in reasonable agreement with direct essentiality calls for S. oneidensis, but agreed more closely with E. coli essentiality calls for orthologs. The TIFA gene essentiality calls were in good agreement with the MR-1 FBA essentiality predictions, and the agreement between TIFA and FBA predictions was substantially better than between the FBA and the direct gene essentiality predictions.

  10. Interface Promoted Reversible Mg Insertion in Nanostructured Tin-Antimony Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yingwen; Shao, Yuyan; Parent, Lucas R.; Sushko, Maria L.; Li, Guosheng; Sushko, Petr; Browning, Nigel D.; Wang, Chong M.; Liu, Jun

    2015-11-11

    This paper demonstrates intermetallic compounds SnSb are highly active materials for reversibly hosting Mg ions. Compared with monometallic Sn and Sb, SnSb alloy exhibited exceptionally high reversible capacity (420 mAh/g), excellent rate capability and good cyclic stability. Mg insertion into pristine SnSb involves an activation process to complete, which induces particle breakdown and results in phase segregation to Sn-rich and Sb-rich phases. Both experimental analysis and DFT simulation suggest that the Sn-rich phase is particularly active and provides most of the capacity whereas the Sb-rich phase is not as active, and the interface between these two phases play a key role in promoting the formation and stabilization of the cubic Sn phase that is more favorable for fast and reversible Mg insertion. We further show that activated SnSb alloy has good compatibility with simple Mg electrolytes. Overall, this work could provide new approaches for designing materials capable of reversible Mg ion insertion and new opportunities for understanding Mg electrochemistry.

  11. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.P. [Westinghouse Savannah River Company, AIKEN, SC (United States)

    1997-09-18

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Either new DWPF analytical method could result in a two to three fold improvement in sample analysis time.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples.The insert sample is named after the initial trials which placed the container inside the sample (peanut) vials. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock

  12. Placental cord insertion and birthweight discordance in twin pregnancies: results of the national prospective ESPRiT Study.

    Science.gov (United States)

    Kent, Etaoin M; Breathnach, Fionnuala M; Gillan, John E; McAuliffe, Fionnuala M; Geary, Michael P; Daly, Sean; Higgins, John R; Dornan, James; Morrison, John J; Burke, Gerard; Higgins, Shane; Carroll, Stephen; Dicker, Patrick; Manning, Fiona; Malone, Fergal D

    2011-10-01

    The purpose of this study was to evaluate the impact of noncentral placental cord insertion on birthweight discordance in twins. We performed a multicenter, prospective trial of twin pregnancies. Placental cord insertion was documented as central, marginal, or velamentous according to a defined protocol. Association of the placental cord insertion site with chorionicity, birthweight discordance, and growth restriction were assessed. Eight hundred sixteen twin pairs were evaluated; 165 pairs were monochorionic, and 651 pairs were dichorionic. Monochorionic twins had higher rates of marginal (P = .0068) and velamentous (P < .0001) placental cord insertion. Noncentral placental cord insertion was more frequent in smaller twins of discordant pairs than control pairs (29.8% vs 19.1%; P = .004). Velamentous placental cord insertion in monochorionic twins was associated significantly with birthweight discordance (odds ratio, 3.5; 95% confidence interval, 1.3-9.4) and growth restriction (odds ratio, 4; 95% confidence interval, 1.1-14.3). Noncentral placental cord insertion contributes to birthweight discordance in monochorionic twin pregnancies. Sonographic delineation of placental cord insertion may be of value in antenatal assessment of twin pregnancies. Copyright © 2011 Mosby, Inc. All rights reserved.

  13. Performance of Silicon carbide whisker reinforced ceramic inserts on Inconel 718 in end milling process

    International Nuclear Information System (INIS)

    Reddy, M M; Joshua, C X H

    2016-01-01

    An experimental investigation is planned in order to study the machinability of Inconel 718 with silicon carbide whisker reinforced ceramic inserts in end milling process. The relationship between the cutting speed, feed rate, and depth of cut against the response factors are studied to show the level of significance of each parameter. The cutting parameters are optimized by using Taguchi method. Implementing analysis of variance, the parameter which influences the surface roughness the most is determined to be the cutting speed, followed by the feed rate and depth of cut. Meanwhile, the optimal cutting condition is determined to have high cutting speed, low feed rate, and high depth of cut in the range of selected parameters. (paper)

  14. Equivalent threshold sound pressure levels for Sennheiser HDA 200 earphone and Etymotic Research ER-2 insert earphone in the frequency range 125 Hz to 16 kHz

    DEFF Research Database (Denmark)

    Han, Loc A; Poulsen, Torben

    1998-01-01

    Equivalent Threshold Sound Pressure Levels (ETSPLs) have been determined for the Sennheiser HDA 200 earphone and the Etymotic Research ER-2insert earphone. Thirty-one young normal-hearing test subjects participated and the thresholds were determined for all recommended frequencies in thefrequency...

  15. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  16. Two stents insertion via single tract for treatment of hepatic hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Xie Zonggui; Jin Peng; Xie Zhiyong; Yi Yuhai; Zhang Xuping

    2003-01-01

    Objective: To evaluate the feasibility and clinical application of two stents insertion via single tract for treatment of hepatic hilar cholangiocarcinoma. Methods: Eighteen patients with hepatic hilar cholangiocarcinoma who had left and right bile duct obstruction were treated with stents insertion via right bile duct puncturing routeway. These two stents were implanted between right and left bile duct, and between right bile duct and common bile duct. Results: Eighteen patients obtained successful two stents placement by right bile duct puncturing tract and succeeded with internal drainage for all biliary tree jaundice subsided distinctly. Conclusions: The technique of two stents insertion via single tract could predigest interventional drainage procedure of high bile duct obstruction, reduce operation trauma, shorten handling time and possess promising application value

  17. Insertion devices and beamlines for the proposed Australian synchrotron light source

    International Nuclear Information System (INIS)

    Garrett, R.F.; Boldeman, J.W.

    1999-01-01

    Full text: The proposed Australian synchrotron light source, Boomerang, is a third generation 3 GeV storage ring which is designed to provide for the great majority of Australian requirements for synchrotron radiation well into the next century. The storage ring could accommodate up to 60 experimental stations, including beamlines from 9 insertion devices, which far exceeds the projected Australian requirements over the life of the facility. Undulator radiation will be available up to 20 keV. The first phase construction of Boomerang includes funding for 9 beamlines, comprising 5 bending magnet and 4 insertion device beamlines. The beamline complement has been chosen to cater for approximately 95% of the current and projected Australian demand for synchrotron radiation over the first 5 years operation of the facility. Details will be shown of the performance of the proposed insertion devices, and the initial beamline complement will be presented

  18. MiMIC: a highly versatile transposon insertion resource for engineering Drosophila melanogaster genes

    Science.gov (United States)

    Venken, Koen J. T.; Schulze, Karen L.; Haelterman, Nele A.; Pan, Hongling; He, Yuchun; Evans-Holm, Martha; Carlson, Joseph W.; Levis, Robert W.; Spradling, Allan C.; Hoskins, Roger A.; Bellen, Hugo J.

    2011-01-01

    We demonstrate the versatility of a collection of insertions of the transposon Minos mediated integration cassette (MiMIC), in Drosophila melanogaster. MiMIC contains a gene-trap cassette and the yellow+ marker flanked by two inverted bacteriophage ΦC31 attP sites. MiMIC integrates almost at random in the genome to create sites for DNA manipulation. The attP sites allow the replacement of the intervening sequence of the transposon with any other sequence through recombinase mediated cassette exchange (RMCE). We can revert insertions that function as gene traps and cause mutant phenotypes to wild type by RMCE and modify insertions to control GAL4 or QF overexpression systems or perform lineage analysis using the Flp system. Insertions within coding introns can be exchanged with protein-tag cassettes to create fusion proteins to follow protein expression and perform biochemical experiments. The applications of MiMIC vastly extend the Drosophila melanogaster toolkit. PMID:21985007

  19. Insertion of lithium in Nb2O5

    International Nuclear Information System (INIS)

    Alves, M.C.M.; Bulhoes, L.O.S.; Castro, S.C.

    1990-01-01

    The electrode process during the reduction and oxidation of Nb sub(2) O sub(5) by cyclic voltametry was characterized. The surface analysis by X-ray photo electronic spectroscopy allowed characterize the surface processes, that happening during the insertion reaction. (author)

  20. The ATLAS Insertable B-Layer Detector (IBL)

    CERN Document Server

    Huegging, F; The ATLAS collaboration

    2010-01-01

    The upgrade for the ATLAS detector will undergo different phases towards SLHC. The first upgrade for the Pixel Detector will consist in the construction of a new pixel layer which will be installed during a longer shutdown of the LHC machine, the so-called Phase I Upgrade. The new detector, called Insertable B-Layer (IBL), will be inserted between the existing pixel detector and a new (smaller radius) beam-pipe at a radius of about 3.2 cm. The IBL requires the development of several new technologies to cope with the increase of radiation and pixel occupancy as well as to improve the physics performance of the existing pixel detector. In order to achieve these goals the pixel size is reduced and the material budget is minimized by using new lightweight mechanical support materials and a CO2 based cooling system. Main component of the module development for the IBL is the new ATLAS pixel readout chip, FE-I4, designed in 130 nm technology which features an array of 80 by 336 pixels with a pixel size of 50x250 µ...

  1. Comparison of bougie-guided insertion of Proseal tm laryngeal mask airway with digital technique in adults

    Directory of Open Access Journals (Sweden)

    Anand Kuppusamy

    2010-01-01

    Full Text Available The Proseal TM laryngeal mask airway (PLMA TM , Laryngeal Mask Company, UK was designed to improve ventilatory characteristics and offer protection against regurgitation and gastric insufflation. The PLMA is a modified laryngeal mask airway with large ventral cuff, dorsal cuff and a drain tube. These modifications improve seal around glottis and enable better ventilatory characteristics. The drain tube prevents gastric distension and offers protection against aspiration. There were occasional problems, like failed insertion and inadequate ventilation, in placing PLMA TM using the classical digital technique. To overcome these problems, newer placement techniques like thumb insertion technique, introducer tool placement and gum elastic bougie (GEB-aided placement were devised. We compared classical digital placement of PLMA TM with gum elastic bougie-aided technique in 60 anaesthetised adult patients (with 30 patients in each group with respect to number of attempts to successful placement, effective airway time, airway trauma during insertion, postoperative airway morbidity and haemodynamic response to insertion. The number of attempts to successful placement, airway trauma during insertion and haemodynamic response to insertion were comparable among the two groups, while effective airway time and oropharyngeal leak pressure were significantly higher in bougie- guided insertion of PLMA. Postoperatively, sore throat was more frequent with digital technique while dysphagia was more frequent with bougie-guided technique. Hence gum elastic bougie guided, laryngoscope aided insertion of PLMA is an excellent alternate to classical digital technique.

  2. The FADE mass-stat: A technique for inserting or deleting particles in molecular dynamics simulations

    Energy Technology Data Exchange (ETDEWEB)

    Borg, Matthew K., E-mail: matthew.borg@strath.ac.uk [Department of Mechanical and Aerospace Engineering, University of Strathclyde, Glasgow G1 1XJ (United Kingdom); Lockerby, Duncan A., E-mail: duncan.lockerby@warwick.ac.uk [School of Engineering, University of Warwick, Coventry CV4 7AL (United Kingdom); Reese, Jason M., E-mail: jason.reese@ed.ac.uk [School of Engineering, University of Edinburgh, Edinburgh EH9 3JL (United Kingdom)

    2014-02-21

    The emergence of new applications of molecular dynamics (MD) simulation calls for the development of mass-statting procedures that insert or delete particles on-the-fly. In this paper we present a new mass-stat which we term FADE, because it gradually “fades-in” (inserts) or “fades-out” (deletes) molecules over a short relaxation period within a MD simulation. FADE applies a time-weighted relaxation to the intermolecular pair forces between the inserting/deleting molecule and any neighbouring molecules. The weighting function we propose in this paper is a piece-wise polynomial that can be described entirely by two parameters: the relaxation time scale and the order of the polynomial. FADE inherently conserves overall system momentum independent of the form of the weighting function. We demonstrate various simulations of insertions of atomic argon, polyatomic TIP4P water, polymer strands, and C{sub 60} Buckminsterfullerene molecules. We propose FADE parameters and a maximum density variation per insertion-instance that restricts spurious potential energy changes entering the system within desired tolerances. We also demonstrate in this paper that FADE compares very well to an existing insertion algorithm called USHER, in terms of accuracy, insertion rate (in dense fluids), and computational efficiency. The USHER algorithm is applicable to monatomic and water molecules only, but we demonstrate that FADE can be generally applied to various forms and sizes of molecules, such as polymeric molecules of long aspect ratio, and spherical carbon fullerenes with hollow interiors.

  3. The FADE mass-stat: A technique for inserting or deleting particles in molecular dynamics simulations

    International Nuclear Information System (INIS)

    Borg, Matthew K.; Lockerby, Duncan A.; Reese, Jason M.

    2014-01-01

    The emergence of new applications of molecular dynamics (MD) simulation calls for the development of mass-statting procedures that insert or delete particles on-the-fly. In this paper we present a new mass-stat which we term FADE, because it gradually “fades-in” (inserts) or “fades-out” (deletes) molecules over a short relaxation period within a MD simulation. FADE applies a time-weighted relaxation to the intermolecular pair forces between the inserting/deleting molecule and any neighbouring molecules. The weighting function we propose in this paper is a piece-wise polynomial that can be described entirely by two parameters: the relaxation time scale and the order of the polynomial. FADE inherently conserves overall system momentum independent of the form of the weighting function. We demonstrate various simulations of insertions of atomic argon, polyatomic TIP4P water, polymer strands, and C 60 Buckminsterfullerene molecules. We propose FADE parameters and a maximum density variation per insertion-instance that restricts spurious potential energy changes entering the system within desired tolerances. We also demonstrate in this paper that FADE compares very well to an existing insertion algorithm called USHER, in terms of accuracy, insertion rate (in dense fluids), and computational efficiency. The USHER algorithm is applicable to monatomic and water molecules only, but we demonstrate that FADE can be generally applied to various forms and sizes of molecules, such as polymeric molecules of long aspect ratio, and spherical carbon fullerenes with hollow interiors

  4. Recent advances in C(sp3–H bond functionalization via metal–carbene insertions

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2016-04-01

    Full Text Available The recent development of intermolecular C–H insertion in the application of C(sp3–H bond functionalizations, especially for light alkanes, is reviewed. The challenging problem of regioselectivity in C–H bond insertions has been tackled by the use of sterically bulky metal catalysts, such as metal porphyrins and silver(I complexes. In some cases, high regioselectivity and enantioselectivity have been achieved in the C–H bond insertion of small alkanes. This review highlights the most recent accomplishments in this field.

  5. A regenerative electrochemical biosensor for mercury(II) by using the insertion approach and dual-hairpin-based amplification

    International Nuclear Information System (INIS)

    Jia, Jing; Ling, Yu; Gao, Zhong Feng; Lei, Jing Lei; Luo, Hong Qun; Li, Nian Bing

    2015-01-01

    Highlights: • The dual-hairpin structure as a signal amplifier is label-free and handy. • The strategy uses the insertion approach to improve the hybridization efficiency. • This biosensor has a low detection limit (28 pM) for detection of Hg 2+ . • This biosensor can be easily regenerated by using L-cysteine. - Abstract: A simple and effective biosensor for Hg 2+ determination was investigated. The novel biosensor was prepared by the insertion approach that the moiety-labeled DNA inserted into a loosely packed cyclic-dithiothreitol (DTT) monolayer, improving the hybridization efficiency. Electrochemical impedance spectroscopy studies of two biosensors (single-hairpin and dual-hairpin structure DNA modified electrodes) used for Hg 2+ detection indicated that the dual-hairpin modified electrode had a larger electron transfer resistance change (ΔR ct ). Consequently, the dual-hairpin structure was used as a signal amplifier for the preparation of a selective Hg 2+ biosensor. This biosensor exhibited an excellent selectivity toward Hg 2+ over Cd 2+ , Pd 2+ , Co 2+ etc. Also, a linear relation was observed between the ΔR ct and Hg 2+ concentrations in a range from 0.1 nM to 5 μM with a detection limit of 28 pM under optimum conditions. Moreover, the biosensor can be reused by using L-cysteine and successfully applied for detecting Hg 2+ in real samples

  6. Direction of catheter insertion and the incidence of paresthesia during continuous epidural anesthesia in the elderly patients

    Science.gov (United States)

    Kim, Jong-Hak; Lee, Jun Seop

    2013-01-01

    Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568

  7. Characterization of full-length sequenced cDNA inserts (FLIcs) from Atlantic salmon (Salmo salar)

    Science.gov (United States)

    Andreassen, Rune; Lunner, Sigbjørn; Høyheim, Bjørn

    2009-01-01

    Background Sequencing of the Atlantic salmon genome is now being planned by an international research consortium. Full-length sequenced inserts from cDNAs (FLIcs) are an important tool for correct annotation and clustering of the genomic sequence in any species. The large amount of highly similar duplicate sequences caused by the relatively recent genome duplication in the salmonid ancestor represents a particular challenge for the genome project. FLIcs will therefore be an extremely useful resource for the Atlantic salmon sequencing project. In addition to be helpful in order to distinguish between duplicate genome regions and in determining correct gene structures, FLIcs are an important resource for functional genomic studies and for investigation of regulatory elements controlling gene expression. In contrast to the large number of ESTs available, including the ESTs from 23 developmental and tissue specific cDNA libraries contributed by the Salmon Genome Project (SGP), the number of sequences where the full-length of the cDNA insert has been determined has been small. Results High quality full-length insert sequences from 560 pre-smolt white muscle tissue specific cDNAs were generated, accession numbers [GenBank: BT043497 - BT044056]. Five hundred and ten (91%) of the transcripts were annotated using Gene Ontology (GO) terms and 440 of the FLIcs are likely to contain a complete coding sequence (cCDS). The sequence information was used to identify putative paralogs, characterize salmon Kozak motifs, polyadenylation signal variation and to identify motifs likely to be involved in the regulation of particular genes. Finally, conserved 7-mers in the 3'UTRs were identified, of which some were identical to miRNA target sequences. Conclusion This paper describes the first Atlantic salmon FLIcs from a tissue and developmental stage specific cDNA library. We have demonstrated that many FLIcs contained a complete coding sequence (cCDS). This suggests that the remaining c

  8. Characterization of full-length sequenced cDNA inserts (FLIcs from Atlantic salmon (Salmo salar

    Directory of Open Access Journals (Sweden)

    Lunner Sigbjørn

    2009-10-01

    Full Text Available Abstract Background Sequencing of the Atlantic salmon genome is now being planned by an international research consortium. Full-length sequenced inserts from cDNAs (FLIcs are an important tool for correct annotation and clustering of the genomic sequence in any species. The large amount of highly similar duplicate sequences caused by the relatively recent genome duplication in the salmonid ancestor represents a particular challenge for the genome project. FLIcs will therefore be an extremely useful resource for the Atlantic salmon sequencing project. In addition to be helpful in order to distinguish between duplicate genome regions and in determining correct gene structures, FLIcs are an important resource for functional genomic studies and for investigation of regulatory elements controlling gene expression. In contrast to the large number of ESTs available, including the ESTs from 23 developmental and tissue specific cDNA libraries contributed by the Salmon Genome Project (SGP, the number of sequences where the full-length of the cDNA insert has been determined has been small. Results High quality full-length insert sequences from 560 pre-smolt white muscle tissue specific cDNAs were generated, accession numbers [GenBank: BT043497 - BT044056]. Five hundred and ten (91% of the transcripts were annotated using Gene Ontology (GO terms and 440 of the FLIcs are likely to contain a complete coding sequence (cCDS. The sequence information was used to identify putative paralogs, characterize salmon Kozak motifs, polyadenylation signal variation and to identify motifs likely to be involved in the regulation of particular genes. Finally, conserved 7-mers in the 3'UTRs were identified, of which some were identical to miRNA target sequences. Conclusion This paper describes the first Atlantic salmon FLIcs from a tissue and developmental stage specific cDNA library. We have demonstrated that many FLIcs contained a complete coding sequence (cCDS. This

  9. Exponential Megapriming PCR (EMP) Cloning—Seamless DNA Insertion into Any Target Plasmid without Sequence Constraints

    Science.gov (United States)

    Ulrich, Alexander; Andersen, Kasper R.; Schwartz, Thomas U.

    2012-01-01

    We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts. PMID:23300917

  10. Band gap evaluations of metal-inserted titania nanomaterials

    International Nuclear Information System (INIS)

    Bashir, Sajid; Liu, Jingbo; Zhang Hui; Sun Xuhui; Guo Jinghua

    2013-01-01

    The electronic and crystalline properties of iron-inserted titania (Fe x Ti 1−x O 2 ) nanoparticles were measured using synchrotron-based soft X-ray spectroscopy and high-temperature X-ray powder diffraction (HT-XRD). The data from X-ray absorption and emission spectroscopy were used to examine occupied and unoccupied densities of states for O 2p and Ti/Fe 3d hybrid orbital characteristics. It was found that Fe 3+ insertion resulted in an up-shift of the band gap from 3.20 to 3.46 eV. This observation reflected site occupancy in the TiO 2 lattice by Fe dopant ions. From HT-XRD Rietveld analysis, Ti occupancy was found to be 0.92 and oxygen 1.00. In addition, the crystal structure remained anatase within a temperature range of 25–800 °C, while the lattice distortion increased due to thermal expansion.

  11. Planning of Hiatus-Breaking Inserted /?/ in the Speech of Australian English-Speaking Children

    Science.gov (United States)

    Yuen, Ivan; Cox, Felicity; Demuth, Katherine

    2017-01-01

    Purpose: Non-rhotic varieties of English often use /?/ insertion as a connected speech process to separate heterosyllabic V1.V2 hiatus contexts. However, there has been little research on children's development of this strategy. This study investigated whether children use /?/ insertion and, if so, whether hiatus-breaking /?/ can be considered…

  12. Li Insertion Into Li-Ti-O Spinels: Voltammetric and Electrochemical Impedance Spectroscopy Study

    Czech Academy of Sciences Publication Activity Database

    Krtil, Petr; Fattakhova, Dina

    2001-01-01

    Roč. 148, č. 9 (2001), s. A1045-A1050 ISSN 0013-4651 R&D Projects: GA ČR GA203/99/0879 Institutional research plan: CEZ:AV0Z4040901 Keywords : Li insertion * impedance spectroscopy * Frumkin insertion isotherm Subject RIV: CG - Electrochemistry Impact factor: 2.033, year: 2001

  13. Challenges for Insertion of Structural Nanomaterials in Aerospace Applications

    Science.gov (United States)

    Sochi, Emilie J.

    2012-01-01

    In the two decades since Iijima's report on carbon nanotubes (CNT), there has been great interest in realizing the benefits of mechanical properties observed at the nanoscale in large-scale structures. The weight savings possible due to dramatic improvements in mechanical properties relative to state-of-the-art material systems can be game changing for applications like aerospace vehicles. While there has been significant progress in commercial production of CNTs, major aerospace applications that take advantage of properties offered by this material have yet to be realized. This paper provides a perspective on the technical challenges and barriers for insertion of CNTs as an emerging material technology in aerospace applications and proposes approaches that may reduce the typical timeframe for technology maturation and insertion into aerospace structures.

  14. Calculation of magnetic error fields in hybrid insertion devices

    International Nuclear Information System (INIS)

    Savoy, R.; Halbach, K.; Hassenzahl, W.; Hoyer, E.; Humphries, D.; Kincaid, B.

    1989-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory requires insertion devices with fields sufficiently accurate to take advantage of the small emittance of the ALS electron beam. To maintain the spectral performance of the synchrotron radiation and to limit steering effects on the electron beam these errors must be smaller than 0.25%. This paper develops a procedure for calculating the steering error due to misalignment of the easy axis of the permanent magnet material. The procedure is based on a three dimensional theory of the design of hybrid insertion devices developed by one of us. The acceptable tolerance for easy axis misalignment is found for a 5 cm period undulator proposed for the ALS. 11 refs., 5 figs

  15. Supercritical Water Mixture (SCWM) Experiment in the High Temperature Insert-Reflight (HTI-R)

    Science.gov (United States)

    Hicks, Michael C.; Hegde, Uday G.; Garrabos, Yves; Lecoutre, Carole; Zappoli, Bernard

    2013-01-01

    Current research on supercritical water processes on board the International Space Station (ISS) focuses on salt precipitation and transport in a test cell designed for supercritical water. This study, known as the Supercritical Water Mixture Experiment (SCWM) serves as a precursor experiment for developing a better understanding of inorganic salt precipitation and transport during supercritical water oxidation (SCWO) processes for the eventual application of this technology for waste management and resource reclamation in microgravity conditions. During typical SCWO reactions any inorganic salts present in the reactant stream will precipitate and begin to coat reactor surfaces and control mechanisms (e.g., valves) often severely impacting the systems performance. The SCWM experiment employs a Sample Cell Unit (SCU) filled with an aqueous solution of Na2SO4 0.5-w at the critical density and uses a refurbished High Temperature Insert, which was used in an earlier ISS experiment designed to study pure water at near-critical conditions. The insert, designated as the HTI-Reflight (HTI-R) will be deployed in the DECLIC (Device for the Study of Critical Liquids and Crystallization) Facility on the International Space Station (ISS). Objectives of the study include measurement of the shift in critical temperature due to the presence of the inorganic salt, assessment of the predominant mode of precipitation (i.e., heterogeneously on SCU surfaces or homogeneously in the bulk fluid), determination of the salt morphology including size and shapes of particulate clusters, and the determination of the dominant mode of transport of salt particles in the presence of an imposed temperature gradient. Initial results from the ISS experiments will be presented and compared to findings from laboratory experiments on the ground.

  16. Increasing of the cutting power at inserts for application in the area of power industry

    Energy Technology Data Exchange (ETDEWEB)

    Fulemova, Jaroslava; Janda, Zdenek [University of West Bohemia in Pilsen, Faculty of mechanical engineering, Department of Machining technology, Plzen (Czech Republic)

    2013-07-01

    This article deals with the influence of cutting edge preparation on tool life, cutting forces and the roughness of machined surface. The cutting edge preparation was done on the inserts with wiper geometry which are used during machining of dividing plane at a steam turbine casing. This cutting inserts were prepared by the technology of drag finishing on the edge radius 5, 10 and 15 µ m. The work piece material was ferritic – martensitic steel with the content of 9%Mo and 1%Cr and the material of cutting inserts was submicron sintered carbide. There was used only one cutting insert in the milling cutter. Key words: edge radius, milling, tool life, roughness, forces.

  17. Design and Characterization of Bioadhesive In-Situ Gelling Ocular Inserts of Gatifloxacin Sesquihydrate

    Directory of Open Access Journals (Sweden)

    Mishra D.N.

    2008-03-01

    Full Text Available Background and purpose of the study: Several polymeric systems have been used to fabricate ocular inserts for better ocular bioavailability and retention to drug of which gelling systems have shown advantages of convenient administration and increased contact time. The purpose of the present study was to develop a bioadhesive in-situe gelling ocular insert of Gatifloxacin using polymeric system of sodium alginate as gelling and chitosan as bioadhesive agent.Materials and methods: Polymeric ocular inserts of Gatifloxacin sesquehydrate (GS were composed using sodium alginate and chitosan with glycerin as plasticizer by solvent casting method. The ocular inserts were investigated for physicochemical properties (thickness, weight variation, folding endurance and surface pH, mechanical strength (tensile strength, elongation at break, swelling index, and bioadhesion parameters. In vitro release studies were carried using a fabricated donor-receptor compartment model. Results: Cumulative drug released from the formulation ranged from 95-99% within 8-12h. The formulation D (2% sodium alginate and 1% chitosan sustained the drug release for the longest period of time (12h. Zero-order release of the drug was from optimized formulation D. A high correlation coefficient (r=0.9845 was recorded between in vitro and in vivo drug release.Conclusion: Gatifloxacin sesquehydrate inserts have appreciable film forming properties and were found to posses good antimicrobial efficacy.

  18. Velamentous Cord Insertion: Significance of Prenatal Detection to Predict Perinatal Complications

    Directory of Open Access Journals (Sweden)

    Junichi Hasegawa

    2006-03-01

    Full Text Available In the maternal and child health statistics of Japan for 2003, perinatal deaths were most frequent in pregnant women with abnormalities of the placenta, umbilical cord, and fetal membrane. Despite advances in perinatal medicine, approximately 2% of low-risk pregnant women still require an emergency cesarean section after the onset of labor. Because it is likely that half of these cases are associated with placental and umbilical cord abnormalities, it is thought that prenatal detection of such abnormalities would reduce the number of emergency cesarean sections in low-risk women. In our previous studies, some abnormalities of the placenta and umbilical cord were associated with abnormalities of cord insertion. Furthermore, we reported that prenatal detection of velamentous cord insertion (VCI reduced the number of emergency cesarean sections in low-risk women. In this review, we describe the prenatal detection of abnormalities of umbilical cord insertion and the management of VCI based on our current clinical data.

  19. Development of a nasogastric tube insertion simulator: a collaborative interdisciplinary effort.

    Science.gov (United States)

    Summer, Lindsay; Gonzalez, Laura; Jimeno, Miguel; Christensen, Ken

    2009-01-01

    The nursing faculty shortage has created the need for more innovative and effective ways to better stimulate nursing students. Simulation technology is one way to increase the effectiveness of teaching faculty. In this article, a collaborative project between the College of Nursing and College of Engineering at the University of South Florida to develop and evaluate a PC-based software simulator based on videogame technologies for nursing skill acquisition is discussed. A software simulator for teaching and assessing mastery of the procedure for nasogastric tube insertion is described. The purpose of the simulator is to complement the standard training of nasogastric tube insertion that uses static mannequins and instruction/assessment by nursing instructors. The simulator was used in a fundamentals of nursing class at the University of South Florida, with 75 students enrolled. Evaluation showed that the simulator significantly increased the confidence of the students in their ability to perform nasogastric tube insertion.

  20. Perbandingan Bubble Sort dengan Insertion Sort pada Bahasa Pemrograman C dan Fortran

    Directory of Open Access Journals (Sweden)

    Reina Reina

    2013-12-01

    Full Text Available Sorting is a basic algorithm studied by students of computer science major. Sorting algorithm is the basis of other algorithms such as searching algorithm, pattern matching algorithm. Bubble sort is a popular basic sorting algorithm due to its easiness to be implemented. Besides bubble sort, there is insertion sort. It is lesspopular than bubble sort because it has more difficult algorithm. This paper discusses about process time between insertion sort and bubble sort with two kinds of data. First is randomized data, and the second is data of descending list. Comparison of process time has been done in two kinds of programming language that is C programming language and FORTRAN programming language. The result shows that bubble sort needs more time than insertion sort does.

  1. Chimeric polyomavirus-derived virus-like particles: the immunogenicity of an inserted peptide applied without adjuvant to mice depends on its insertion site and its flanking linker sequence

    OpenAIRE

    Lawatscheck, R.; Aleksaite, E.; Schenk, J.A.; Micheel, B.; Jandrig, B.; Holland, G.; Sasnauskas, K.; Gedvilaite, A.; Ulrich, R.G.

    2007-01-01

    We inserted the sequence of the carcinoembryonic antigen-derived T cell epitope CAP-1-6D (CEA) into different positions of the hamster polyomavirus major capsid protein VP1. Independently from additional flanking linkers, yeast-expressed VP1 proteins harboring the CEA insertion between VP1 amino acid residues 80 and 89 (site 1) or 288 and 295 (site 4) or simultaneously at both positions assembled to chimeric virus-like particles (VLPs). BALB/c mice immunized with adjuvant-free VLPs developed ...

  2. An order insertion scheduling model of logistics service supply chain considering capacity and time factors.

    Science.gov (United States)

    Liu, Weihua; Yang, Yi; Wang, Shuqing; Liu, Yang

    2014-01-01

    Order insertion often occurs in the scheduling process of logistics service supply chain (LSSC), which disturbs normal time scheduling especially in the environment of mass customization logistics service. This study analyses order similarity coefficient and order insertion operation process and then establishes an order insertion scheduling model of LSSC with service capacity and time factors considered. This model aims to minimize the average unit volume operation cost of logistics service integrator and maximize the average satisfaction degree of functional logistics service providers. In order to verify the viability and effectiveness of our model, a specific example is numerically analyzed. Some interesting conclusions are obtained. First, along with the increase of completion time delay coefficient permitted by customers, the possible inserting order volume first increases and then trends to be stable. Second, supply chain performance reaches the best when the volume of inserting order is equal to the surplus volume of the normal operation capacity in mass service process. Third, the larger the normal operation capacity in mass service process is, the bigger the possible inserting order's volume will be. Moreover, compared to increasing the completion time delay coefficient, improving the normal operation capacity of mass service process is more useful.

  3. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  4. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    Science.gov (United States)

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and

  5. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Intracesarean insertion of the Copper T380A versus 6 weeks postcesarean: a randomized clinical trial.

    Science.gov (United States)

    Lester, Felicia; Kakaire, Othman; Byamugisha, Josaphat; Averbach, Sarah; Fortin, Jennifer; Maurer, Rie; Goldberg, Alisa

    2015-03-01

    To compare rates of Copper T380A intrauterine device (IUD) utilization and satisfaction with immediate versus delayed IUD insertion after cesarean delivery in Kampala, Uganda. This study was a randomized clinical trial of women undergoing cesarean section who desired an IUD in Kampala, Uganda. Participants were randomly assigned to IUD insertion at the time of cesarean delivery or 6weeks afterward. The primary outcome was IUD utilization at 6months after delivery. Among 68 women who underwent randomization, an IUD was inserted in 100% (34/34) of the women in the immediate insertion group and in 53% (18/34) in the delayed group. IUD use at 6 months was higher in the immediate insertion group (93% vs. 50% after delayed insertion; pcontraceptive method compared to 44% (11/25) of nonusers (pWomen who chose not to be in the study or had the IUD removed often did so because of perceived husband or community disapproval. The 6-month utilization of an IUD after immediate insertion was significantly higher than after delayed insertion without increased complications. Contraceptive satisfaction was significantly higher among IUD users than nonusers. Community and husband attitudes influence IUD utilization and continuation in Kampala, Uganda. This work is important because it shows the safety and efficacy of providing IUDs during cesarean section in a setting where access to any healthcare, including contraception, can be extremely limited outside of childbearing and the consequences of an unintended, closely spaced pregnancy after a cesarean section can be life threatening. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Zero insertion force socket for photoactivation patient treatment system

    International Nuclear Information System (INIS)

    Troutner, V.H.

    1988-01-01

    Automatic operating zero insertion force socket for use in a photoactivatable reagent treatment system wherein photoactivatable agents, in contact with patient blood cells, are irradiated extracorporeally and then returned to the patient

  8. Effect of embedded dexamethasone in cochlear implant array on insertion forces in an artificial model of scala tympani.

    Science.gov (United States)

    Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier

    2015-02-01

    Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.

  9. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  10. Exponential megapriming PCR (EMP cloning--seamless DNA insertion into any target plasmid without sequence constraints.

    Directory of Open Access Journals (Sweden)

    Alexander Ulrich

    Full Text Available We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.

  11. Bone suture anchor fixation in the lower extremity: a review of insertion principles and a comparative biomechanical evaluation.

    Science.gov (United States)

    Scranton, Pierce E; Lawhon, S Michael; McDermott, John E

    2005-07-01

    Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

  12. Predictors for cecal insertion time: the impact of abdominal visceral fat measured by computed tomography.

    Science.gov (United States)

    Nagata, Naoyoshi; Sakamoto, Kayo; Arai, Tomohiro; Niikura, Ryota; Shimbo, Takuro; Shinozaki, Masafumi; Noda, Mitsuhiko; Uemura, Naomi

    2014-10-01

    Several factors affect the risk for longer cecal insertion time. The aim of this study was to identify the predictors of longer insertion time and to evaluate the effect of visceral fat measured by CT. This is a retrospective observational study. Outpatients for colorectal cancer screening who underwent colonoscopies and CT were enrolled. Computed tomography was performed in individuals who requested cancer screening and in those with GI bleeding. Information on obesity indices (BMI, visceral adipose tissue, and subcutaneous adipose tissue area), constipation score, history of abdominal surgery, poor preparation, fellow involvement, diverticulosis, patient discomfort, and the amount of sedation used was collected. The cecal insertion rate was 95.2% (899/944), and 899 patients were analyzed. Multiple regression analysis showed that female sex, lower BMI, lower visceral adipose tissue area, lower subcutaneous adipose tissue area, higher constipation score, history of surgery, poor bowel preparation, and fellow involvement were independently associated with longer insertion time. When obesity indices were considered simultaneously, smaller subcutaneous adipose tissue area (p = 0.038), but not lower BMI (p = 0.802) or smaller visceral adipose tissue area (p = 0.856), was associated with longer insertion time; the other aforementioned factors remained associated with longer insertion time. In the subanalysis of normal-weight patients (BMI abdominal fat, female sex, constipation, history of abdominal surgery, poor preparation, and fellow involvement were predictors of longer cecal insertion time. Among the obesity indices, high subcutaneous fat accumulation was the best predictive factor for easier passage of the colonoscope, even when body weight was normal.

  13. The clinical practice of inserting two stents in esophagus and trachea

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Gao Xuemei; Ma Nan; Wang Yanli; Li Yongdong

    2005-01-01

    Objective: To study the value of clinical practice of inserting two stents in esophagus and trachea. Methods: Four esophagorespiratory fistulas with severe tracheal stenosis and 7 esophageal stenosises with severe tracheal stenosis, were taken stent placement under fluoroscopic guidance. Results: All cases had their stents placed successfully, with normal diet intake without difficulty together with immediate disappearance of dysprea. Conclusions: It is safe, effective for patients with esophageal cancerous stenosis (or fistula) and tracheal stenosis to be treated by two stents insertion method. (authors)

  14. Rhodium (II) carbene C-H insertion in water and catalyst reuse

    International Nuclear Information System (INIS)

    Candeias, Nuno R.; Gois, Pedro M.P.; Afonso, Carlos A.M.

    2007-01-01

    A five-session laboratory experiment is described for the synthesis of a beta-lactam via Rh(II) catalysed intramolecular C-H insertion of a alpha-diazo-alpha-ethoxycarbonyl acetamide. The metallo-carbene, responsible for the C-H bond activation, was generated from the diazo substrate and the catalyst Rh 2 (OAc) 4 . The high stability and solubility of the catalyst and the exclusive C-H insertion of the Rh-carbene allows the synthesis of this important heterocycle in water and the catalyst reutilization. (author)

  15. Biomimetic hydrogels gate transport of calcium ions across cell culture inserts.

    Science.gov (United States)

    Kotanen, Christian N; Wilson, A Nolan; Wilson, Ann M; Ishihara, Kazuhiko; Guiseppi-Elie, Anthony

    2012-06-01

    Control of the in vitro spatiotemporal availability of calcium ions is one means by which the microenvironments of hematopoietic stem cells grown in culture may be reproduced. The effects of cross-linking density on the diffusivity of calcium ions through cell culture compatible poly(2-hydroxyethyl methacrylate) [poly(HEMA)]-based bioactive hydrogels possessing 1.0 mol% 2-methacryloyloxyethyl phosphorylcholine (MPC), 5 mol% N,N-(dimethylamino)ethylmethacrylate (DMAEMA) and ca. 17 mol% n-butyl acrylate (n-BA) have been investigated to determine if varying cross-link density is a viable approach to controlling transport of calcium across hydrogel membranes. Cross-linking density was varied by changing the composition of cross-linker, tetraethyleneglycol diacrylate (TEGDA). The hydrogel membranes were formed by sandwich casting onto the external surface of track-etched polycarbonate membranes (T = 10 μm, φ = 0.4 μm pores) of cell culture inserts, polymerized in place by UV light irradiation and immersed in buffered (0.025 HEPES, pH 7.4) 0.10 M calcium chloride solution. The transport of calcium ions across the hydrogel membrane was monitored using a calcium ion selective electrode set within the insert. Degree of hydration (21.6 ± 1.0%) and void fraction were found to be constant across all cross-linking densities. Diffusion coefficients, determined using time-lag analysis, were shown to be strongly dependent on and to exponentially decrease with increasing cross-linking density. Compared to that found in buffer (2.0-2.5 × 10⁻⁶ cm²/s), diffusion coefficients ranged from 1.40 × 10⁻⁶ cm²/s to 1.80 × 10⁻⁷ cm²/s and tortuosity values ranged from 1.7 to 10.0 for the 1 and 12 mol% TEGDA cross-linked hydrogels respectively. Changes in tortuosity arising from variations in cross-link density were found to be the primary modality for controlling diffusivity through novel n-BA containing poly(HEMA)-based bioactive hydrogels.

  16. Experimental Investigation on Tool Wear Behavior and Cutting Temperature during Dry Machining of Carbon Steel SAE 1030 Using KC810 and KC910 Coated Inserts

    Directory of Open Access Journals (Sweden)

    Y. Tamerabet

    2018-03-01

    Full Text Available The removal of cutting fluids and lubrication in dry machining operations requires a good knowledge and full control of all the mechanisms that lead to tool damage. In order to optimize dry machining operations, it is necessary to clearly identify the wear patterns, determine the contact conditions and define the relationship between the contact parameters and the operating conditions. The idea is to choose optimal cutting conditions which lead to the best contact conditions limiting the triggering or aggravation of wear phenomena. The purpose of this paper is to determine the impact multilayer coatings and cutting parameters on tool wear and temperature at the tool-chip interface for two types of coated carbides (KC810 and KC910 Commercialized inserts during dry turning operation of carbon steel SAE 1030, in order to determine the ideal parameters and guarantee the best performances of the cutting tools. Cutting temperature, Crater and Flank wear have been systematically recorded in order to determine their influence on tool life time. To ensure the optimum choice of machining conditions; the TAGUCHI method associated to multi-factorial method were applied to plan the experiments. It has been noted that cutting speed was the most influential factor on temperature and wear evolution. We noted also that the KC810 insert was more suitable for machining of SAE 1030 Carbon Steel; where The best life time was registered (T=228 min. The KC810 inserts offer 30 min of additional machining time for the same work conditions.

  17. FRET-based localization of fluorescent protein insertions within the ryanodine receptor type 1.

    Directory of Open Access Journals (Sweden)

    Shweta A Raina

    Full Text Available Fluorescent protein (FP insertions have often been used to localize primary structure elements in mid-resolution 3D cryo electron microscopic (EM maps of large protein complexes. However, little is known as to the precise spatial relationship between the location of the fused FP and its insertion site within a larger protein. To gain insights into these structural considerations, Förster resonance energy transfer (FRET measurements were used to localize green fluorescent protein (GFP insertions within the ryanodine receptor type 1 (RyR1, a large intracellular Ca(2+ release channel that plays a key role in skeletal muscle excitation contraction coupling. A series of full-length His-tagged GFP-RyR1 fusion constructs were created, expressed in human embryonic kidney (HEK-293T cells and then complexed with Cy3NTA, a His-tag specific FRET acceptor. FRET efficiency values measured from each GFP donor to Cy3NTA bound to each His tag acceptor site were converted into intermolecular distances and the positions of each inserted GFP were then triangulated relative to a previously published X-ray crystal structure of a 559 amino acid RyR1 fragment. We observed that the chromophoric centers of fluorescent proteins inserted into RyR1 can be located as far as 45 Å from their insertion sites and that the fused proteins can also be located in internal cavities within RyR1. These findings should prove useful in interpreting structural results obtained in cryo EM maps using fusions of small fluorescent proteins. More accurate point-to-point distance information may be obtained using complementary orthogonal labeling systems that rely on fluorescent probes that bind directly to amino acid side chains.

  18. College Degree, Insertion in the Job Market and Social Background: Limitations and Possibilities

    Directory of Open Access Journals (Sweden)

    Ana Heloísa da Costa Lemos

    2014-04-01

    Full Text Available The goal of this study was to investigate the impact of college education on the professional insertion of undergraduates from the Business Administration Course. In order to help achieve its objectives, a study was launched in 2007, 2008 and 2009 with business administration students that studied at a famous private university in RJ, which intended to understand the possible relation in obtaining a diploma, the social status of those who get a diploma and its insertion in the job market. The students chosen to participate at this survey were attending the last semester and different variables were taken into consideration such as socioeconomic status, parents educational level and current occupation. The study intended to identify possible differences between the opportunities to find a job among the participants with higher or lower income. The research results did not indicate that there is any difference between the two groups as possibilities of insertion in the market place, reinforcing the idea that the decisive factor in regard to social and professional insertion is related to education.

  19. Reference hearing threshold levels for chirp signals delivered by an ER-3A insert earphone

    DEFF Research Database (Denmark)

    Gøtsche-Rasmussen, Kristian; Poulsen, Torben; Elberling, Claus

    2012-01-01

    back from a Tucker Davies Technologies System II, and a Matlab program controlled the test setup. The results are specified in dB peak-to-peak equivalent threshold sound pressure levels (dB peETSPL). Study sample: The test group consisted of 25 otologically-normal young adults (age 18–25 years......Objective: To establish reference hearing threshold levels for chirps and frequency-specific chirps. Design: Hearing thresholds were determined monaurally for broad-band chirps and octave-band chirps using the Etymotic Research, ER-3A insert earphone. The chirps were presented using two repetition...

  20. Insertional mutagenesis using Tnt1 retrotransposon in potato

    Science.gov (United States)

    Potato is the third most important food crop in the world. However, genetics and genomics research of potato has lagged behind many major crop species due to its autotetraploidy and a highly heterogeneous genome. Insertional mutagenesis using T-DNA or transposable elements, which is available in sev...

  1. Training of nurses on Foley catheter insertion in intensive care unit patients: limits and possibilities

    Directory of Open Access Journals (Sweden)

    Magno Conceição Merces

    2013-04-01

    Full Text Available Backgound and Objectives: Nursing has an important role in urinary tract infection prevention and control. Urinary catheters insertion represents the local topography with the highest rate of hospital infection. Foley catheter placement is performed solely by the nurse and requires aseptic techniques during its performance, thus preventing risks to the patients. The study aimed to evaluate the training of nurses on Foley catheter insertion and point out limits and possibilities of this practice in patients at the Intensive Care Unit (ICU of Hospital Geral do Interior da Bahia (HGIB. Methods: This was a qualitative, exploratory and descriptive study. Data collection was carried out through semi-structured interviews. After data analysis, two categories were evaluated, namely: the training of nurses on Foley catheter insertion in ICU patients and the limits and possibilities of Foley catheter insertion practice by nurses in ICU patients. Bardin analysis was used for data analysis. Results: The study shows that the nurse’s practice on Foley catheter insertion in ICU patients is based on the use of aseptic techniques for urinary tract infection prevention, theoretical and practical knowledge on Foley catheter insertion in ICU patients, knowledge on urinary tract infections and associations with catheter insertion, whereas the limits and possibilities of Foley catheter insertion practice by nurses are understood through measures to minimize the risk of hospital infection caused by long-term catheter use in the ICU. Nurses point out that the risks of hospital infection are inherent to long-term catheter use. This is an important fact, as the knowledge or its absence may constitute a limit or possibility for Foley catheter insertion practice by the nurse in ICU patients. Conclusion: Nurses must seek the systematization of knowledge, which warrants support for the team, as well as information, safety and prompt care, allowing the reduction of urinary

  2. Correlation between extension-block K-wire insertion angle and postoperative extension loss in mallet finger fracture.

    Science.gov (United States)

    Lee, S K; Kim, Y H; Moon, K H; Choy, W S

    2018-02-01

    Extension-block pinning represents a simple and reliable surgical technique. Although this procedure is commonly performed successfully, some patients develop postoperative extension loss. To date, the relationship between extension-block Kirschner wire (K-wire) insertion angle and postoperative extension loss in mallet finger fracture remains unclear. We aimed to clarify this relationship and further evaluate how various operative and non-operative factors affect postoperative extension loss after extension-block pinning for mallet finger fracture. A retrospective study was conducted to investigate a relationship between extension block K-wire insertion angle and postoperative extension loss. The inclusion criteria were: (1) a dorsal intra-articular fracture fragment involving 30% of the base of the distal phalanx with or without volar subluxation of the distal phalanx; and (2) block K-wire insertion angle and fixation angle of the distal interphalangeal (DIP) joint were assessed using lateral radiograph at immediate postoperative time. Postoperative extension loss was assessed by using lateral radiograph at latest follow-up. Extension-block K-wire insertion angle was defined as the acute angle between extension block K-wire and longitudinal axis of middle phalangeal head. DIP joint fixation angle was defined as the acute angle between the distal phalanx and middle phalanx longitudinal axes. Seventy-five patients were included. The correlation analysis revealed that extension-block K-wire insertion angle had a negative correlation with postoperative extension loss, whereas fracture size and time to operation had a positive correlation (correlation coefficient for extension block K-wire angle: -0.66, facture size: +0.67, time to operation: +0.60). When stratifying patients in terms of negative and positive fixation angle of the DIP joint, the independent t-test showed that mean postoperative extension loss is -3.67° and +4.54° (DIP joint fixation angles of block

  3. Ant System-Corner Insertion Sequence: An Efficient VLSI Hard Module Placer

    Directory of Open Access Journals (Sweden)

    HOO, C.-S.

    2013-02-01

    Full Text Available Placement is important in VLSI physical design as it determines the time-to-market and chip's reliability. In this paper, a new floorplan representation which couples with Ant System, namely Corner Insertion Sequence (CIS is proposed. Though CIS's search complexity is smaller than the state-of-the-art representation Corner Sequence (CS, CIS adopts a preset boundary on the placement and hence, leading to search bound similar to CS. This enables the previous unutilized corner edges to become viable. Also, the redundancy of CS representation is eliminated in CIS leads to a lower search complexity of CIS. Experimental results on Microelectronics Center of North Carolina (MCNC hard block benchmark circuits show that the proposed algorithm performs comparably in terms of area yet at least two times faster than CS.

  4. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao; Falivene, Laura; Boffa, Giusi; Sá nchez, Sheila Ortega; Caporaso, Lucia; Grassi, Alfonso; Mecking, Stefan

    2016-01-01

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively

  5. Validation of an improved abnormality insertion method for medical image perception investigations

    Science.gov (United States)

    Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.

    2009-02-01

    The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.

  6. The effects of lavender aromatherapy on pain following needle insertion into a fistula in hemodialysis patients.

    Science.gov (United States)

    Bagheri-Nesami, Masoumeh; Espahbodi, Fatemeh; Nikkhah, Attieh; Shorofi, Seyed Afshin; Charati, Jamshid Yazdani

    2014-02-01

    This study sought to determine the effects of lavender aromatherapy on pain following needle insertion into a fistula in patients undergoing hemodialysis. This is a randomized controlled clinical trial in which 92 patients undergoing hemodialysis with arteriovenous fistulas were randomly divided into two groups. The experimental-group patients inhaled lavender essence with a concentration of 10% for 5 min during 3 hemodialysis sessions, while the control-group patients received aromatherapy free of lavender essence. The mean VAS pain intensity score in the experimental and control groups before the intervention was 3.78 ± 0.24 and 4.16 ± 0.32, respectively (p = 0.35). The mean VAS pain intensity score in the experimental and control groups after three aromatherapy sessions was 2.36 ± 0.25 and 3.43 ± 0.31, respectively (p = 0.009). Lavender aromatherapy may be an effective technique to reduce pain following needle insertion into a fistula in hemodialysis patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Filter and window assemblies for high power insertion device synchrotron radiation sources

    International Nuclear Information System (INIS)

    Khounsary, A.M.; Viccaro, P.J.; Kuzay, T.M.

    1992-01-01

    The powerful beams of x-ray radiation generated by insertion devices at high power synchrotron facilities deposit substantial amounts of localized heat in the front end and optical components that they intercept. X-ray beams from undulator sources, in particular, are confined to very narrow solid angles and therefore impose very high absorbed heat fluxes. This paper is devoted to a detailed study of the design of windows for the Advanced Photon Source undulators and wigglers, emphasizing alternative design concepts, material considerations, and cooling techniques necessary for handling the high heat load of the insertion devices. Various designs are thermally and structurally analyzed by numerically simulating full-power operating conditions. This analysis also has relevance to the design and development of other beam line components which are subjected to the high heat loads of insertion devices

  8. Oral analgesia vs intravenous conscious sedation during Essure Micro-Insert sterilization procedure: randomized, double-blind, controlled trial.

    Science.gov (United States)

    Thiel, John A; Lukwinski, Angelina; Kamencic, Huse; Lim, Hyung

    2011-01-01

    To compare the pain reported by patients during the Essure Micro-Insert sterilization procedure using either intravenous conscious sedation or oral analgesia. Randomized, double-blind, placebo-controlled trial (Canadian Task Force classification I). Tertiary care ambulatory women's clinic. Eighty women of reproductive age women requesting permanent sterilization. Hysteroscopic placement of the Essure Micro-Insert permanent birth control system. Patients undergoing placement of the Essure Micro-Insert system for permanent contraception were randomized to receive either intravenous conscious sedation, oral analgesia, or placebo. During the procedure, pain scores were recorded using a visual analog scale. Patients in the oral analgesia group reported slightly more pain during insertion of the hysteroscope and placement of the second micro-insert; the groups were otherwise equivalent. They were also equivalent when all visual analog scale scores were combined. Oral analgesia is an effective method of pain control during placement of the Essure Micro-Insert permanent birth control system. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  10. Suction catheter guided insertion of ProSeal laryngeal mask airway: Experience by untrained physicians

    Directory of Open Access Journals (Sweden)

    Valter Perilli

    2014-01-01

    Full Text Available Background: The use of suction catheter (SC has been shown to improve success rate during ProSeal laryngeal mask airway (PLMA insertion in expert users. Aims: The aim of this study was to compare insertion of PLMA performed by untrained physicians using a SC or the digital technique (DT in anaesthetised non-paralysed patients. Methods: In this prospective randomised double-blind study, conducted in the operating setting, 254 patients (American Society of Anaesthesiologists I-II, aged 18-65 years, undergoing minor surgery were enrolled. Exclusion criteria were body mass index >35 kg/m 2 , laryngeal or oesophageal varices, risk of aspiration or difficult face mask ventilation either referred or suspected (Langeron′s criteria ≥2 and modified Mallampati classification score >2. Participants were randomly allocated to one of the two groups in which PLMA was inserted using DT (DT-group or SC (SC-group. Statistical Analysis: Chi-square test with Yates′ correction, Mann-Whitney U-test or Student′s t-test were carried-out as appropriate. Results: The final insertion success rate was greater in SC-groupcompared with DT-group 90.1% (n = 109 versus 74.4% (n = 99 respectively (P = 0.002. Mean airway leak pressure was higher in SC-group compared to DT-group (23.7 ± 3.9 vs. 21.4 ± 3.2 respectively; (P = 0.001. There were no differences in insertion time, post-operative airway morbidity and complications. Conclusion: The findings of this study suggest that SC-technique improves the success rate of PLMA insertion by untrained physicians.

  11. CUDA accelerated simulation of needle insertions in deformable tissue

    International Nuclear Information System (INIS)

    Patriciu, Alexandru

    2012-01-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  12. First two barrel ECAL supermodules inserted in CMS HCAL

    CERN Multimedia

    K.Bell

    2006-01-01

    The first two barrel "supermodules" for the CMS Electromagnetic Calorimeter (ECAL) have been inserted into the barrel hadron calorimeter (HCAL) in the experimental hall (called SX5) in Cessy in preparation for the forthcoming magnet test and cosmic challenge (MTCC). Each of the two supermodules contains 1700 lead tungstate crystals in glass-fibre alveolar support structures, with associated avalanche photodiodes (APDs, for scintillation light detection), electronics and cooling system. The barrel ECAL will consist of 36 supermodules, many of which have already been produced (see CERN Bulletin 17-18, 2006). Team from CMS ECAL, CMS Integration and CEA-DAPNIA were involved in the insertion, with the production/integration of the supermodules themselves involving many technicians, engineers and physicists from many institutes. From left to right: Olivier Teller, Maf Alidra and Lucien Veillet.

  13. Tune shift and betatron modulations due to insertion devices in SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.

    1989-12-01

    SPEAR will soon operate as a dedicated synchrotron radiation source with up to 5 beamlines fed from insertion devices. These magnets introduce additional focusing forces into the storage ring lattice which increase the vertical betatron tune and modulate the beam envelope in the vertical plane. The lattice simulation code 'GEMINI' is used to evaluate the tune shifts and estimate the degree of betatron modulation as each magnetic insertion device is brought up to full power. A program is recommended to correct the tunes with the FODO cell quadrupoles. 4 refs., 8 figs., 1 tab

  14. Three-year follow-up of children with postmeningitic deafness and partial cochlear implant insertion.

    NARCIS (Netherlands)

    Rotteveel, L.J.C.; Snik, A.F.M.; Vermeulen, A.M.J.; Mylanus, E.A.M.

    2005-01-01

    OBJECTIVES: To evaluate the long-term outcome of children with postmeningitic deafness and partial insertion of the Nucleus electrode array, and to compare their speech perception performance with that of children with full insertion of the electrode array. DESIGN: A battery of seven speech

  15. Safety analysis for reactivity insertion on ADS

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia S.; Velasquez, Carlos E.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Costa, Antonella L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Barros, Graiciany de P. [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, an accelerator driven system (ADS) has been studied to fuel regeneration, partitioning and transmutation using fuel removed from LWR-spent fuel. This spent fuel was reprocessed by GANEX and then spiked with thorium. Monteburns 2.0 (MCNP5/ORIGEN 2.1) code was used to simulate burnup and neutronic parameters of the systems. However, these systems might be interrupted for some technical problems during few days or long periods to perform maintenance of accelerator systems without shutdown the fission system. Therefore, in this work, the aim was to investigate the nuclear fuel evolution in three different cases with reactivity insertions and variations in the functionality of the ADS. The evaluation has been performed for a burnup of 3 years, which are the most dangerous years in case of reactivity insertions. Therefore, in the first case the ADS during its burnup the external source (spallation source) is cutting off from the system several times during the first year of burnup. In the second case, it is simulated the reactor at different power from 0 (shutdown) to 1.5 times the 515MWt. The results shows the safety limits of the ADS for different situation. (author)

  16. Folding and membrane insertion of the pore-forming peptide gramicidin occur as a concerted process.

    Science.gov (United States)

    Hicks, Matthew R; Damianoglou, Angeliki; Rodger, Alison; Dafforn, Timothy R

    2008-11-07

    Many antibiotic peptides function by binding and inserting into membranes. Understanding this process provides an insight into the fundamentals of both membrane protein folding and antibiotic peptide function. For the first time, in this work, flow-aligned linear dichroism (LD) is used to study the folding of the antibiotic peptide gramicidin. LD provides insight into the combined processes of peptide folding and insertion and has the advantage over other similar techniques of being insensitive to off-membrane aggregation events. By combining LD data with conventional measurements of protein fluorescence and circular dichroism, the mechanism of gramicidin insertion is elucidated. The mechanism consists of five separately assignable steps that include formation of a water-insoluble gramicidin aggregate, dissociation from the aggregate, partitioning of peptide to the membrane surface, oligomerisation on the surface and concerted insertion and folding of the peptide to the double-helical form of gramicidin. Measurement of the rates of each step shows that although changes in the fluorescence signal cease 10 s after the initiation of the process, the insertion of the peptide into the membrane is actually not complete for a further 60 min. This last membrane insertion phase is only apparent by measurement of LD and circular dichroism signal changes. In summary, this study demonstrates the importance of multi-technique approaches, including LD, in studies of membrane protein folding.

  17. Cost and Morbidity Analysis of Chest Port Insertion: Interventional Radiology Suite Versus Operating Room.

    Science.gov (United States)

    LaRoy, Jennifer R; White, Sarah B; Jayakrishnan, Thejus; Dybul, Stephanie; Ungerer, Dirk; Turaga, Kiran; Patel, Parag J

    2015-06-01

    To compare complications and cost, from a hospital perspective, of chest port insertions performed in an interventional radiology (IR) suite versus in surgery in an operating room (OR). This study was approved by an institutional review board and is HIPAA compliant. Medical records were retrospectively searched on consecutive chest port placement procedures, in the IR suite and the OR, between October 22, 2010 and February 26, 2013, to determine patients' demographic information and chest port-related complications and/or infections. A total of 478 charts were reviewed (age range: 21-85 years; 309 women, 169 men). Univariate and bivariate analyses were performed to identify risk factors associated with an increased complication rate. Cost data on 149 consecutive Medicare outpatients (100 treated in the IR suite; 49 treated in the OR) who had isolated chest port insertions between March 2012 and February 2013 were obtained for both the operative services and pharmacy. Nonparametric tests for heterogeneity were performed using the Kruskal-Wallis method. Early complications occurred in 9.2% (22 of 239) of the IR patients versus 13.4% (32 of 239) of the OR patients. Of the 478 implanted chest ports, 9 placed in IR and 18 placed in surgery required early removal. Infections from the ports placed in IR versus the OR were 0.25 versus 0.18 infections per 1000 catheters, respectively. Overall mean costs for chest port insertion were significantly higher in the OR, for both room and pharmacy costs (P chest ports in an OR setting was almost twice that of placement in the IR suite. Hospital costs to place a chest port were significantly lower in the IR suite than in the OR, whereas radiology and surgery patients did not show a significantly different rate of complications and/or infections. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Use of a National Continuing Medical Education Meeting to Provide Simulation-Based Training in Temporary Hemodialysis Catheter Insertion Skills: A Pre-Test Post-Test Study

    Directory of Open Access Journals (Sweden)

    Edward G Clark

    2014-10-01

    Full Text Available Background: Simulation-based-mastery-learning (SBML is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs. Previous studies of SBML for NTHC-insertion have been conducted at a local level. Objectives: Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Design: Pre-test – post-test study. Setting: 2014 Canadian Society of Nephrology annual meeting. Participants: Nephrology fellows, internal medicine residents and medical students. Measurements: Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Methods: Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Results: Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21. Seventeen of 22 participants (77% completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001. All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics

  19. Use of a national continuing medical education meeting to provide simulation-based training in temporary hemodialysis catheter insertion skills: a pre-test post-test study.

    Science.gov (United States)

    Clark, Edward G; Paparello, James J; Wayne, Diane B; Edwards, Cedric; Hoar, Stephanie; McQuillan, Rory; Schachter, Michael E; Barsuk, Jeffrey H

    2014-01-01

    Simulation-based-mastery-learning (SBML) is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs). Previous studies of SBML for NTHC-insertion have been conducted at a local level. Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME) meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Pre-test - post-test study. 2014 Canadian Society of Nephrology annual meeting. Nephrology fellows, internal medicine residents and medical students. Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS) previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21). Seventeen of 22 participants (77%) completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001). All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics, prior experience or procedural self-confidence with pre-test performance. Small sample-size and

  20. Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws

    Directory of Open Access Journals (Sweden)

    Henrique Alves Cruz

    2013-08-01

    Full Text Available OBJECTIVE: Posterior pelvic lesions, especially of the sacral-iliac joint, have high mortality and morbidity risks. Definitive fixation is necessary for the joint stabilization, and one option is the sacral percutaneous pinning with screws. Proximity to important structures to this region brings risks to the fixation procedure; therefore, it is important to know the tridimensional anatomy of the pelvis posterior region. Deviations of the surgeon's hand of four degrees may target the screws to those structures; dimorphisms of the upper sacrum and a poor lesion reduction may redound in a screw malpositioning. This study is aimed to evaluate the dimensions of a safe surgical corridor for safe sacroiliac screw insertion and relations with age and sex of the patients. METHOD: One hundred randomly selected pelvis CTs of patients with no pelvic diseases, seen at a tertiary care teaching Hospital. Measurements were made by computer and the safest area for screw insertion was calculated by two methods. The results were expressed in mm (not in degrees, in order to be a further surgical reference. RESULTS: There was a significant size difference in the analyzed sacral vertebra, differing on a wider size in men than in women. There was no significant statistical difference between vertebral size and age. By both methods, a safe area for screw insertion could be defined. CONCLUSION: Age does not influence the width of the surgical corridor. The surgeon has a safe corridor considered narrower when inserting screws in a female pelvis than when in a male one. However, as the smallest vertebra found (feminine was considered for statics, it was concluded that this corridor is 20 mm wide in any direction, taking as a reference the centrum of the vertebra.

  1. Active role of a human genomic insert in replication of a yeast artificial chromosome.

    Science.gov (United States)

    van Brabant, A J; Fangman, W L; Brewer, B J

    1999-06-01

    Yeast artificial chromosomes (YACs) are a common tool for cloning eukaryotic DNA. The manner by which large pieces of foreign DNA are assimilated by yeast cells into a functional chromosome is poorly understood, as is the reason why some of them are stably maintained and some are not. We examined the replication of a stable YAC containing a 240-kb insert of DNA from the human T-cell receptor beta locus. The human insert contains multiple sites that serve as origins of replication. The activity of these origins appears to require the yeast ARS consensus sequence and, as with yeast origins, additional flanking sequences. In addition, the origins in the human insert exhibit a spacing, a range of activation efficiencies, and a variation in times of activation during S phase similar to those found for normal yeast chromosomes. We propose that an appropriate combination of replication origin density, activation times, and initiation efficiencies is necessary for the successful maintenance of YAC inserts.

  2. Ty1-copia elements reveal diverse insertion sites linked to polymorphisms among flax (Linum usitatissimum L.) accessions.

    Science.gov (United States)

    Galindo-González, Leonardo; Mhiri, Corinne; Grandbastien, Marie-Angèle; Deyholos, Michael K

    2016-12-07

    Initial characterization of the flax genome showed that Ty1-copia retrotransposons are abundant, with several members being recently inserted, and in close association with genes. Recent insertions indicate a potential for ongoing transpositional activity that can create genomic diversity among accessions, cultivars or varieties. The polymorphisms generated constitute a good source of molecular markers that may be associated with phenotype if the insertions alter gene activity. Flax, where accessions are bred mainly for seed nutritional properties or for fibers, constitutes a good model for studying the relationship of transpositional activity with diversification and breeding. In this study, we estimated copy number and used a type of transposon display known as Sequence-Specific Amplification Polymorphisms (SSAPs), to characterize six families of Ty1-copia elements across 14 flax accessions. Polymorphic insertion sites were sequenced to find insertions that could potentially alter gene expression, and a preliminary test was performed with selected genes bearing transposable element (TE) insertions. Quantification of six families of Ty1-copia elements indicated different abundances among TE families and between flax accessions, which suggested diverse transpositional histories. SSAPs showed a high level of polymorphism in most of the evaluated retrotransposon families, with a trend towards higher levels of polymorphism in low-copy number families. Ty1-copia insertion polymorphisms among cultivars allowed a general distinction between oil and fiber types, and between spring and winter types, demonstrating their utility in diversity studies. Characterization of polymorphic insertions revealed an overwhelming association with genes, with insertions disrupting exons, introns or within 1 kb of coding regions. A preliminary test on the potential transcriptional disruption by TEs of four selected genes evaluated in three different tissues, showed one case of significant

  3. Thought insertion as a self-disturbance: An integration of predictive coding and phenomenological approaches

    Directory of Open Access Journals (Sweden)

    Philipp Sterzer

    2016-10-01

    Full Text Available Current theories in the framework of hierarchical predictive coding propose that positive symptoms of schizophrenia, such as delusions and hallucinations, arise from an alteration in Bayesian inference, the term inference referring to a process by which learned predictions are used to infer probable causes of sensory data. However, for one particularly striking and frequent symptom of schizophrenia, thought insertion, no plausible account has been proposed in terms of the predictive-coding framework. Here we propose that thought insertion is due to an altered experience of thoughts as coming from nowhere, as is already indicated by the early 20th century phenomenological accounts by the early Heidelberg School of psychiatry. These accounts identified thought insertion as one of the self-disturbances (from German: Ichstörungen of schizophrenia and used mescaline as a model-psychosis in healthy individuals to explore the possible mechanisms. The early Heidelberg School (Gruhle, Mayer-Gross, Beringer first named and defined the self-disturbances, and proposed that thought insertion involves a disruption of the inner connectedness of thoughts and experiences, and a becoming sensory of those thoughts experienced as inserted. This account offers a novel way to integrate the phenomenology of thought insertion with the predictive coding framework. We argue that the altered experience of thoughts may be caused by a reduced precision of context-dependent predictions, relative to sensory precision. According to the principles of Bayesian inference, this reduced precision leads to increased prediction-error signals evoked by the neural activity that encodes thoughts. Thus, in analogy with the prediction-error related aberrant salience of external events that has been proposed previously, internal events such as thoughts (including volitions, emotions and memories can also be associated with increased prediction-error signaling and are thus imbued with

  4. Regional insertion: an emergent approach

    International Nuclear Information System (INIS)

    Serra, M.T.F.; Nascimento Teixeira, P. do

    1989-01-01

    The Brazilian Electrical Sector incorporates new variables that expressing the extensive spectrum of environmental impacts in the take of decisions, referring to the viability of realizing a electrical undertaking, attends the several restrictions that are important by the sector and by the society in the environment area and promotes the adequate generation of liquid benefits, consequential of the electrical undertaking. Due to these factors, the Electrical Sector is improving the concept of regional insertion, with the sectorial expansion in long-dated and the created demand in the environmental and social area, focalizing the solution for these questions. (C.G.C.). 1 fig, 2 tabs

  5. Recent advances in insertion devices

    International Nuclear Information System (INIS)

    Gluskin, E.; Moog, E.R.

    1995-01-01

    Demand for more and better insertion devices (IDs) at new third-generation synchrotron radiation facilities has led to significant advances in ID technology at different laboratories around the world. In this overview of this progress, focus is on those results that apply to IDs in general rather than one specific ID or laboratory. The advances fall into two general categories: those that reduce the net effect that the ID has on the particle beam, and those that enhance the quality of the emitted light spectrum. The need for these advances, factors that are most important inaachieving them, and the current state of the art are discussed

  6. A multiple objective magnet sorting algorithm for the Advanced Light Source insertion devices

    International Nuclear Information System (INIS)

    Humphries, D.; Goetz, F.; Kownacki, P.; Marks, S.; Schlueter, R.

    1995-01-01

    Insertion devices for the Advanced Light Source (ALS) incorporate large numbers of permanent magnets which have a variety of magnetization orientation errors. These orientation errors can produce field errors which affect both the spectral brightness of the insertion devices and the storage ring electron beam dynamics. A perturbation study was carried out to quantify the effects of orientation errors acting in a hybrid magnetic structure. The results of this study were used to develop a multiple stage sorting algorithm which minimizes undesirable integrated field errors and essentially eliminates pole excitation errors. When applied to a measured magnet population for an existing insertion device, an order of magnitude reduction in integrated field errors was achieved while maintaining near zero pole excitation errors

  7. Experience with UIDC insertion outside of menses in Kenya ...

    African Journals Online (AJOL)

    %) or insertion outside of menses (6.9%), than the within menses (4.3%) groups. However, the differences were not statistically significant. Adjusted odds ratios for IUCD outside of menses and oligomenorrhoea/amenorrhea groups were 1.65 ...

  8. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  9. Posology of insulins: A review of standard textbooks and product inserts.

    Science.gov (United States)

    Bhutani, Garima; Kalra, Sanjay

    2015-01-01

    The study is aimed to assess whether the information contained in standard pharmacology, endocrinology, and diabetology textbooks regarding timings of administration, frequency and dose of various insulins is adequate and also to see whether the information contained in these texts is concordant with product inserts. Four standard textbooks of pharmacology, two of diabetology and three of endocrinology were assessed for the published information regarding dose, timing, and frequency of insulin administration. The product inserts of commonly available insulins in India were also studied for the same. Various omissions and disparities could be seen in the coverage of insulins in standard textbooks. Posology information about premixed insulins and basal insulins have been omitted by the majority of the textbooks. Details about dose, frequency and timings of ultra-short acting insulins have also not been covered by all textbooks. Some discrepancies regarding prescribing information was also noted in product inserts, especially in case of newer insulins. Thus, this article stresses upon the need of a uniform source of information for providing adequate and standardized knowledge regarding timing, frequency, and dose of insulins.

  10. The effects of oral sucrose on pain due to nasogastric tube insertion in premature infants: A crossover clinical trial

    Directory of Open Access Journals (Sweden)

    Jebreili M

    2014-11-01

    Full Text Available Background and Objective: Pain in neonates may have adverse impacts. Therefore, relieving pain through harmless, simple, and applicable methods, in order to prevent its dangerous consequences, is of great importance. The aim of the present study is to determine the impact of oral sucrose on relieving nasogastric tube insertion pain in premature neonates. Materials and Method: The present study is a crossover clinical trial on 38 preterm infants (gestational age between 28-34 weeks hospitalized in Bistonoh-e-Bahman Hospital, Tabriz, Iran, in 2013. The subjects were selected by convenience sampling and divided into two groups using randomized block design. In the first group, nasogastric tube insertion was carried out in the routine way for the first time, and for the second time, by administration of oral sucrose. In the second group, the procedure was performed in the reverse order of that in the first group. In both groups the emerging pain was measured by the Premature Infant Pain Profile (PIPP tool 2 minutes before, during, and 5 minutes after the procedure. Data were analyzed using, chi-square t-test, Students' independent test, paired t-test, and repeated measures ANOVA in SPSS version 18 to examine the trend of change in pain in time. P values of less than 0.05 were considered statistically significant. Results: The results showed that oral sucrose reduces the pain response of infants. The mean pain score during the insertion of nasogastric tube and administration of oral sucrose was 5.95 ± 2.35 and during routine procedures was 9.93 ± 2.89 (P < 0.001. The mean pain score 5 minutes after insertion of nasogastric tube with administration of oral sucrose was 3.66 ± 0.57 and routine procedure was 6.38 ± 0.83 (P = 0.017. Conclusion: It was revealed that oral sucrose can relieve pain caused by nasogastric tube insertion. Therefore, its implementation as a harmless and simple method can reduce pain in preterm infants.

  11. Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

    Science.gov (United States)

    McNeely, Heidi L; Ream, Theresa L; Thrasher, Jodi M; Dziadkowiec, Oliwier; Callahan, Tiffany J

    2018-04-01

    Vascular access in pediatric patients can be challenging even with the currently available technological resources. This nurse-driven research study explored time, cost, and resources for intravenous access to determine if a biomedical device, VeinViewer ® Vision, would facilitate improvements in pediatric access. In addition, this study looked at nurse perceptions of skills and confidence around intravenous insertion and if the use of the VeinViewer ® impacted these perceptions. Literature examining pediatric intravenous access success rates compared with nurse perceived skills and confidence is lacking. Nonblinded randomized control trial of pediatric nurses working in an acute care hospital setting. A preliminary needs assessment solicited feedback from nurses regarding their practice, perceived skills, and confidence with placing peripheral intravenous catheters (PIVs). Due to the results of the preliminary needs assessment, a research study was designed and 40 nurses were recruited to participate. The nurses were randomized into either a VeinViewer ® or standard practice group. Nurse participants placed intravenous catheters on hospitalized pediatric patients using established procedures while tracking data for the study. Needs assessment showed a majority of nurses felt a biomedical device would be helpful in building their intravenous insertion skills and their confidence. The study results did not demonstrate any clinically significant differences between VeinViewer ® use and standard practice for intravenous catheter insertion in pediatric patients for success of placement, number of attempts, or overall cost. In addition, no difference was noted between nurses in either group on perceived skills or confidence with insertion of PIVs. The ongoing need for resources focused on building nurse skills and confidence for PIV insertion was highlighted and organizations should continue to direct efforts toward developing skills and competency for staff that

  12. A morphophonological analysis of the velar insert in Italian verbs

    Directory of Open Access Journals (Sweden)

    Nicola Lampitelli

    2017-05-01

    Full Text Available This paper analyzes a particular group of Italian irregular verbs that are characterized by the insertion of [g] between the root and the inflectional markers. Despite the apparent unetymological status of such a velar insert (Rohlfs 1968, it is shown that the allomorphy of the root depends on the internal organization of the segmental material with respect to a fixed template made of a strict alternation of onsets (C and nuclei (V. The analyses are couched within the CVCV framework (Lowenstamm 1996; Scheer 2004 and are consistent with a syntactic approach to word- formation such as Distributed Morphology (Halle & Marantz 1993; Embick 2010. This article is part of the special collection: Motivating Form in Morpho-Syntax

  13. Effects of high density dispersion fuel loading on the uncontrolled reactivity insertion transients of a low enriched uranium fueled material test research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Muhammad, Farhan [Department of Nuclear Engineering, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan)], E-mail: farhan73@hotmail.com; Majid, Asad [Department of Nuclear Engineering, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan)

    2009-08-15

    The effects of using high density low enriched uranium on the uncontrolled reactivity insertion transients of a material test research reactor were studied. For this purpose, the low density LEU fuel of an MTR was replaced with high density U-Mo (9w/o) LEU fuels currently being developed under the RERTR program having uranium densities of 6.57 gU/cm{sup 3}, 7.74 gU/cm{sup 3} and 8.57 gU/cm{sup 3}. Simulations were carried out to determine the reactor performance under reactivity insertion transients with totally failed control rods. Ramp reactivities of 0.25$/0.5 s and 1.35$/0.5 s were inserted with reactor operating at full power level of 10 MW. Nuclear reactor analysis code PARET was employed to carry out these calculations. It was observed that when reactivity insertion was 0.25$/0.5 s, the new power level attained increased by 5.8% as uranium density increases from 6.57 gU/cm{sup 3} to 8.90 gU/cm{sup 3}. This results in increased maximum temperatures of fuel, clad and coolant outlet, achieved at the new power level, by 4.7 K, 4.4 K and 2.4 K, respectively. When reactivity insertion was 1.35$/0.5 s, the feedback reactivities were unable to control the reactor which resulted in the bulk boiling of the coolant; the one with the highest fuel density was the first to reach the boiling point.

  14. YOUNGSTERS INSERTION ON THE LABOUR MARKET. A COMPARATIVE ANALYSIS ROMANIA - EUROPEAN UNION

    Directory of Open Access Journals (Sweden)

    Dobre Mihaela Hrisanta

    2008-05-01

    Full Text Available The insertion of young people into the labor market represents an important issue amongst all the countries within the European Union and this process is studied differently from one country to another. At present the European Union counts about 75 million young people with the age between 15 and 24 years old. This article main objective is to study insertion rate of young people the labour market as well as it deals with their problems.

  15. Perbandingan Bubble Sort dengan Insertion Sort pada Bahasa Pemrograman C dan Fortran

    OpenAIRE

    Reina, Reina; Gautama, Josef Bernadi

    2013-01-01

    Sorting is a basic algorithm studied by students of computer science major. Sorting algorithm is the basis of other algorithms such as searching algorithm, pattern matching algorithm. Bubble sort is a popular basic sorting algorithm due to its easiness to be implemented. Besides bubble sort, there is insertion sort. It is lesspopular than bubble sort because it has more difficult algorithm. This paper discusses about process time between insertion sort and bubble sort with two kinds of data. ...

  16. A regenerative electrochemical biosensor for mercury(II) by using the insertion approach and dual-hairpin-based amplification

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Jing; Ling, Yu; Gao, Zhong Feng [Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Lei, Jing Lei [College of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044 (China); Luo, Hong Qun, E-mail: luohq@swu.edu.cn [Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Li, Nian Bing, E-mail: linb@swu.edu.cn [Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2015-09-15

    Highlights: • The dual-hairpin structure as a signal amplifier is label-free and handy. • The strategy uses the insertion approach to improve the hybridization efficiency. • This biosensor has a low detection limit (28 pM) for detection of Hg{sup 2+}. • This biosensor can be easily regenerated by using L-cysteine. - Abstract: A simple and effective biosensor for Hg{sup 2+} determination was investigated. The novel biosensor was prepared by the insertion approach that the moiety-labeled DNA inserted into a loosely packed cyclic-dithiothreitol (DTT) monolayer, improving the hybridization efficiency. Electrochemical impedance spectroscopy studies of two biosensors (single-hairpin and dual-hairpin structure DNA modified electrodes) used for Hg{sup 2+} detection indicated that the dual-hairpin modified electrode had a larger electron transfer resistance change (ΔR{sub ct}). Consequently, the dual-hairpin structure was used as a signal amplifier for the preparation of a selective Hg{sup 2+} biosensor. This biosensor exhibited an excellent selectivity toward Hg{sup 2+} over Cd{sup 2+}, Pd{sup 2+}, Co{sup 2+} etc. Also, a linear relation was observed between the ΔR{sub ct} and Hg{sup 2+} concentrations in a range from 0.1 nM to 5 μM with a detection limit of 28 pM under optimum conditions. Moreover, the biosensor can be reused by using L-cysteine and successfully applied for detecting Hg{sup 2+} in real samples.

  17. Stability and Reactivity of Cyclometallated Naphthylamine Complexes in Pd-C Bond Insertion Reactions with Coordinated Alkynylphosphanes

    KAUST Repository

    Chen, Shuli

    2013-09-17

    Phenylbis(phenylethynyl)phosphane PhP(C≡CPh)2 coordinates regiospecifically to the α-methyl-chiral ortho-platinated and -palladated naphthylamine units at the positions trans to the nitrogen donors. The P→Pt coordination bond is kinetically inert, whereas the P→Pd bond is labile. Upon heating of these phosphane complexes at 70 °C, one of the C≡C bonds in the coordinated PhP(C≡CPh)2 was activated towards an intermolecular Pd-C bond insertion reaction with an external ortho-palladated naphthylamine ring. No intramolecular insertion reaction occurred. In contrast to its palladium analogue, the ortho-platinated ring is not reactive towards coordinated PhP(C≡CPh)2, although it can promote the Pd-C bond insertion reaction. However, despite the high kinetic stability of the P→Pt coordination, the organoplatinum unit is a noticeably weaker activator than its organopalladium counterpart. The chirality of the reacting ortho-metallated naphthylamine ligand exhibited high stereochemical influence on the formation of the new stereogenic phosphorus center during the course of these C-C bond-formation reactions. The coordination chemistry and the absolute stereochemistry of the dimetallic products were determined by single-crystal X-ray crystallographic analysis. The asymmetric monoinsertion of PhP(C≡CPh)2 coordinated to a cyclometallated N,N-dimethyl naphthyl/benzylamine template into the Pd-C bonds of N,N-dimethylnaphthylamine palladacycles has been demonstrated for the synthesis of a variety of new P-stereogenic homo- or heterodimetallic complexes. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Remanent dose rates around the collimators of the LHC beam cleaning insertions

    International Nuclear Information System (INIS)

    Brugger, M.; Roesler, S.

    2005-01-01

    The LHC will require an extremely powerful and unprecedented collimation system. As ∼30% of the LHC beam is lost in the cleaning insertions, these will become some of the most radioactive locations around the entire LHC ring. Thus, remanent dose rates to be expected during later repair or maintenance interventions must be considered in the design phase itself. As a consequence, the beam cleaning insertions form a unique test bed for a recently developed approach to calculate remanent dose rates. A set of simulations, different in complexity, is used in order to evaluate methods for the estimation of remanent dose rates. The scope, as well as the restrictions, of the omega-factor method are shown and compared with the explicit simulation approach. The latter is then used to calculate remanent dose rates in the beam cleaning insertions. Furthermore, a detailed example for maintenance dose planning is given. (authors)

  19. Remanent dose rates around the collimators of the LHC beam cleaning insertions.

    Science.gov (United States)

    Brugger, M; Roesler, S

    2005-01-01

    The LHC will require an extremely powerful and unprecedented collimation system. As approximately 30% of the LHC beam is lost in the cleaning insertions, these will become some of the most radioactive locations around the entire LHC ring. Thus, remanent dose rates to be expected during later repair or maintenance interventions must be considered in the design phase itself. As a consequence, the beam cleaning insertions form a unique test bed for a recently developed approach to calculate remanent dose rates. A set of simulations, different in complexity, is used in order to evaluate methods for the estimation of remanent dose rates. The scope, as well as the restrictions, of the omega-factor method are shown and compared with the explicit simulation approach. The latter is then used to calculate remanent dose rates in the beam cleaning insertions. Furthermore, a detailed example for maintenance dose planning is given.

  20. Development and validation of a viscoelastic and nonlinear liver model for needle insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yo [Waseda University, Consolidated Research Institute for Advanced Science and Medical Care, Shinjuku, Tokyo (Japan); Onishi, Akinori; Hoshi, Takeharu; Kawamura, Kazuya [Waseda University, Graduate School of Science and Engineering, Shinjuku (Japan); Hashizume, Makoto [Kyushu University Hospital, Center for the Integration of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Fujie, Masakatsu G. [Waseda University, Graduate School of Science and Engineering, Faculty of Science and Engineering, Shinjuku (Japan)

    2009-01-15

    The objective of our work is to develop and validate a viscoelastic and nonlinear physical liver model for organ model-based needle insertion, in which the deformation of an organ is estimated and predicted, and the needle path is determined with organ deformation taken into consideration. First, an overview is given of the development of the physical liver model. The material properties of the liver considering viscoelasticity and nonlinearity are modeled based on the measured data collected from a pig's liver. The method to develop the liver model using FEM is also shown. Second, the experimental method to validate the model is explained. Both in vitro and in vivo experiments that made use of a pig's liver were conducted for comparison with the simulation using the model. Results of the in vitro experiment showed that the model reproduces nonlinear and viscoelastic response of displacement at an internally located point with high accuracy. For a force up to 0.45 N, the maximum error is below 1 mm. Results of the in vivo experiment showed that the model reproduces the nonlinear increase of load upon the needle during insertion. Based on these results, the liver model developed and validated in this work reproduces the physical response of a liver in both in vitro and in vivo situations. (orig.)