WorldWideScience

Sample records for intracardiac electrogram method

  1. Manual Intracardiac Electrogram Method Is Accurate Alternative to Echocardiography for Atrioventricular and Interventricular Optimization in Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka

    2017-12-01

    Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.

  2. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    Science.gov (United States)

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  3. Reliability Of A Novel Intracardiac Electrogram Method For AV And VV Delay Optimization And Comparability To Echocardiography Procedure For Determining Optimal Conduction Delays In CRT Patients

    Directory of Open Access Journals (Sweden)

    N Reinsch

    2009-03-01

    Full Text Available Background: Echocardiography is widely used to optimize CRT programming. A novel intracardiac electrogram method (IEGM was recently developed as an automated programmer-based method, designed to calculate optimal atrioventricular (AV and interventricular (VV delays and provide optimized delay values as an alternative to standard echocardiographic assessment.Objective: This study was aimed at determining the reliability of this new method. Furthermore the comparability of IEGM to existing echocardiographic parameters for determining optimal conduction delays was verified.Methods: Eleven patients (age 62.9± 8.7; 81% male; 73% ischemic, previously implanted with a cardiac resynchronisation therapy defibrillator (CRT-D underwent both echocardiographic and IEGM-based delay optimization.Results: Applying the IEGM method, concordance of three consecutively performed measurements was found in 3 (27% patients for AV delay and in 5 (45% patients for VV delay. Intra-individual variation between three measurements as assessed by the IEGM technique was up to 20 ms (AV: n=6; VV: n=4. E-wave, diastolic filling time and septal-to-lateral wall motion delay emerged as significantly different between the echo and IEGM optimization techniques (p < 0.05. The final AV delay setting was significantly different between both methods (echo: 126.4 ± 29.4 ms, IEGM: 183.6 ± 16.3 ms; p < 0.001; correlation: R = 0.573, p = 0.066. VV delay showed significant differences for optimized delays (echo: 46.4 ± 23.8 ms, IEGM: 10.9 ± 7.0 ms; p <0.01; correlation: R = -0.278, p = 0.407.Conclusion: The automated programmer-based IEGM-based method provides a simple and safe method to perform CRT optimization. However, the reliability of this method appears to be limited. Thus, it remains difficult for the examiner to determine the optimal hemodynamic settings. Additionally, as there was no correlation between the optimal AV- and VV-delays calculated by the IEGM method and the echo

  4. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF

  5. Electrograms (ECG, EEG, EMG, EOG).

    Science.gov (United States)

    Reilly, Richard B; Lee, T Clive

    2010-01-01

    There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.

  6. Machine learning methods for locating re-entrant drivers from electrograms in a model of atrial fibrillation

    Science.gov (United States)

    McGillivray, Max Falkenberg; Cheng, William; Peters, Nicholas S.; Christensen, Kim

    2018-04-01

    Mapping resolution has recently been identified as a key limitation in successfully locating the drivers of atrial fibrillation (AF). Using a simple cellular automata model of AF, we demonstrate a method by which re-entrant drivers can be located quickly and accurately using a collection of indirect electrogram measurements. The method proposed employs simple, out-of-the-box machine learning algorithms to correlate characteristic electrogram gradients with the displacement of an electrogram recording from a re-entrant driver. Such a method is less sensitive to local fluctuations in electrical activity. As a result, the method successfully locates 95.4% of drivers in tissues containing a single driver, and 95.1% (92.6%) for the first (second) driver in tissues containing two drivers of AF. Additionally, we demonstrate how the technique can be applied to tissues with an arbitrary number of drivers. In its current form, the techniques presented are not refined enough for a clinical setting. However, the methods proposed offer a promising path for future investigations aimed at improving targeted ablation for AF.

  7. II.3. Electrograms (ECG, EEG, EMG, EOG).

    Science.gov (United States)

    Reilly, Richard B; Lee, T Clive

    2010-01-01

    There is a constant need in medicine to obtain objective measurements of physical and cognitive function as the basis for diagnosis and monitoring of health. The body can be considered as a chemical and electrical system supported by a mechanical structure. Measuring and quantifying such electrical activity provides a means for objective examination of heath status. The term electrogram, from the Greek electro meaning electricity and gram meaning write or record, is the broad definition given to the recording of electrical signal from the body. In order that comparisons of electrical activity can be made against normative data, certain methods and procedures have been defined for different electrograms. This paper reviews these methods and procedures for the more typical electrograms associated with some of the major organs in the body, providing a first point of reference for the reader.

  8. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Directory of Open Access Journals (Sweden)

    G. Carrault

    2008-09-01

    Full Text Available Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA. The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  9. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Science.gov (United States)

    Kachenoura, A.; Porée, F.; Hernández, A. I.; Carrault, G.

    2008-12-01

    Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs) are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG) from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA). The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  10. Unipolar atrial electrogram morphology from an epicardial and endocardial perspective.

    Science.gov (United States)

    van der Does, Lisette J M E; Knops, Paul; Teuwen, Christophe P; Serban, Corina; Starreveld, Roeliene; Lanters, Eva A H; Mouws, Elisabeth M J P; Kik, Charles; Bogers, Ad J J C; de Groot, Natasja M S

    2018-02-22

    Endo-epicardial asynchrony (EEA) and the interplay between the endocardial and epicardial layers could be important in the pathophysiology of atrial arrhythmias. The morphologic differences between epicardial and endocardial atrial electrograms have not yet been described, and electrogram morphology may hold information about the presence of EEA. The purpose of this study was to directly compare epicardial to endocardial unipolar electrogram morphology during sinus rhythm (SR) and to evaluate whether EEA contributes to electrogram fractionation by correlating fractionation to spatial activation patterns. In 26 patients undergoing cardiac surgery, unipolar electrograms were simultaneously recorded from the epicardium and endocardium at the inferior, middle, and superior right atrial (RA) free wall during SR. Potentials were analyzed for epi-endocardial differences in local activation time, voltage, RS ratio, and fractionation. The surrounding and opposite electrograms of fractionated deflections were evaluated for corresponding local activation times in order to determine whether fractionation originated from EEA. The superior RA was predisposed to delayed activation, EEA, and fractionation. Both epicardial and endocardial electrograms demonstrated an S-predominance. Fractionation was mostly similar between the 2 sides; however, incidentally deflections up to 4 mV on 1 side could be absent on the other side. Remote activation was responsible for most fractionated deflections (95%) in SR, of which 4% could be attributed to EEA. Local epi-endocardial differences in electrogram fractionation occur occasionally during SR but will likely increase during arrhythmias due to increasing EEA and (functional) conduction disorders. Electrogram fractionation can originate from EEA, and this study demonstrated that unipolar electrogram fractionation can potentially identify EEA. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Validation of double-spike electrograms as markers of conduction delay or block in atrial flutter.

    Science.gov (United States)

    Cosio, F G; Arribas, F; Barbero, J M; Kallmeyer, C; Goicolea, A

    1988-04-01

    Recent mapping studies of atrial flutter have shown that fragmented electrograms can be found in most cases from the posterior, posteroseptal and posterolateral walls of the right atrium. The fragmentation pattern most often consists of a double spike. To further assess double-spike electrograms as a possible marker of conduction delay, bipolar electrograms were continuously recorded during atrial overdrive pacing of common flutter from the right atrium (7 patients) and from the proximal coronary sinus (5). Baseline double-spike separation of 50 to 130 ms was unchanged in 1 patient and slightly increased (5 to 25 ms) in 4 by coronary sinus pacing. The electrogram sequence was unchanged and the surface morphology was similar to that of basal flutter. Right atrial pacing decreased double-spike separation by 25 to 85 ms from basal values of 45 to 175 ms (23 to 83%), suggesting fusion in the area of fragmented electrograms. These findings suggest that double-spike electrograms represent activation on both sides of a conduction delay zone. The changes induced in these electrograms by pacing from the anterior right atrium and the coronary sinus are consistent with flutter circuits rotating counterclockwise (frontal plane) in the posterior right atrial wall in common atrial flutter.

  12. Study of intracardiac blood flow by MRI using gradient echo method

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato; Morita, Ruriko; Kusuoka, Hideo; Fujii, Kenshi; Kitabatake, Akira; Takizawa, Osamu.

    1988-06-01

    In order to investigate the possibility of MR imaging for the evaluation of intracardiac blood flow especially valvular regurgitant flow, we obtained MR images using a 1.5 tesla superconductive magnet system (Siemens Medical) in 3 healthy volunteers, 3 patients with hypertrophic cardiomyopathy and 8 patients with valvular heart disease. Rapid FLASH (Fast Low-Angle Shot) imaging technique was applied to collect 11 time frames per section throughout one cardiac cycle in axial, coronal, saggital and oblique sections. Then these sequential frames were displayed in a cine mode on CRT. (1) Intracardiac and intravascular blood flow were visualized with high signal intensity in each frame and cardiac structures such as atria, ventricles, and aorta were also identified in all subjects. (2) Ventricular ejection flow was easily visualized in coronal section as the signal loss in the ascending aorta. Ventricularfilling was visualized in axial and oblique sections as the high signal influx of atrial blood into the ventricle. (3) In 3 patients with aortic regurgitation, regurgitant flow was detected during diastole as the teardrop shaped signal loss originating from aortic valve cusps. (4) Both mitral and tricuspid regurgitant flow were detected during systole as the signal loss in atrium in axial and oblique sections in 2 patients with MR and 2 patients with TR. (5) Pulmonary regurgitant flow was observed in oblique section along the long axis of right ventricular outflow tract. These results indicate that intracardiac forward and regurgitant flow could be identified with rapid FLASH imaging in normal subjects and in patients with valvular heart diseases, and cine mode MR imaging is a useful tool for the evaluation of intracardiac blood flow.

  13. Spatial characterization of electrogram morphology from transmural recordings in the intact normal heart.

    Directory of Open Access Journals (Sweden)

    Jim Pouliopoulos

    Full Text Available PURPOSE: Unipolar (UE and bipolar electrograms (BE are utilized to identify arrhythmogenic substrate. We quantified the effect of increasing distance from the source of propagation on local electrogram amplitude; and determined if transmural electrophysiological gradients exist with respect to propagation and stimulation depth. METHODS: Mapping was performed on 5 sheep. Deployment of >50 quadripolar transmural needles in the LV were located in Cartesian space using Ensite. Contact electrograms from all needles were recorded during multisite bipolar pacing from epicardial then endocardial electrodes. Analysis was performed to determine stimulus distance to local activation time, peak negative amplitude (V-P, and peak-peak amplitude (VP-P for (1 unfiltered UE, and (2 unfiltered and 30 Hz high-pass filtered BEs. Each sheep was analysed using repeated ANOVA. RESULTS: Increasing distance from the pacing sites led to significant (p0.01 during endocardial stimulation, and 2.3±2.4 ms (UE and 1.8±3.7 ms (BE during epicardal stimulation (all pVP-P. Conduction propagates preferentially via the epicardium during stimulation and is believed to contribute to a transmural amplitude gradient.

  14. A study of intracardiac blood flow by MRI using gradient echo method

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato; Morita, Ruriko; Kusuoka, Hideo; Fujii, Kenshi; Kitabatake, Akira; Takizawa, Osamu.

    1988-01-01

    In order to investigate the possibility of MR imaging for the evaluation of intracardiac blood flow especially valvular regurgitant flow, we obtained MR images using a 1.5 tesla superconductive magnet system (Siemens Medical) in 3 healthy volunteers, 3 patients with hypertrophic cardiomyopathy and 8 patients with valvular heart disease. Rapid FLASH (Fast Low-Angle Shot) imaging technique was applied to collect 11 time frames per section throughout one cardiac cycle in axial, coronal, saggital and oblique sections. Then these sequential frames were displayed in a cine mode on CRT. (1) Intracardiac and intravascular blood flow were visualized with high signal intensity in each frame and cardiac structures such as atria, ventricles, and aorta were also identified in all subjects. (2) Ventricular ejection flow was easily visualized in coronal section as the signal loss in the ascending aorta. Ventricularfilling was visualized in axial and oblique sections as the high signal influx of atrial blood into the ventricle. (3) In 3 patients with aortic regurgitation, regurgitant flow was detected during diastole as the teardrop shaped signal loss originating from aortic valve cusps. (4) Both mitral and tricuspid regurgitant flow were detected during systole as the signal loss in atrium in axial and oblique sections in 2 patients with MR and 2 patients with TR. (5) Pulmonary regurgitant flow was observed in oblique section along the long axis of right ventricular outflow tract. These results indicate that intracardiac forward and regurgitant flow could be identified with rapid FLASH imaging in normal subjects and in patients with valvular heart diseases, and cine mode MR imaging is a useful tool for the evaluation of intracardiac blood flow. (author)

  15. Spectral analysis of epicardial 60-lead electrograms in dogs with 4-week-old myocardial infarction.

    Science.gov (United States)

    Hosoya, Y; Ikeda, K; Komatsu, T; Yamaki, M; Kubota, I

    2001-01-01

    There were few studies on the spectral analysis of multiple-lead epicardial electrograms in chronic myocardial infarction. Spectral analysis of multi-lead epicardial electrograms was performed in 6 sham-operated dogs (N group) and 8 dogs with 4-week-old myocardial infarction (MI group). Four weeks after the ligation of left anterior descending coronary artery, fast Fourier transform was performed on 60-lead epicardial electrograms, and then inverse transform was performed on 5 frequency ranges from 0 to 250 Hz. From the QRS onset to QRS offset, the time integration of unsigned value of reconstructed waveform was calculated and displayed as AQRS maps. On 0-25 Hz AQRS map, there was no significant difference between the 2 groups. In the frequency ranges of 25-250 Hz, MI group had significantly smaller AQRS values than N group solely in the infarct zone. It was shown that high frequency potentials (25-250 Hz) within QRS complex were reduced in the infarct zone.

  16. New approach to intracardiac hemodynamic measurements in small animals

    DEFF Research Database (Denmark)

    Eskesen, Kristian; Olsen, Niels T; Dimaano, Veronica L

    2012-01-01

    Invasive measurements of intracardiac hemodynamics in animal models have allowed important advances in the understanding of cardiac disease. Currently they are performed either through a carotid arteriotomy or via a thoracotomy and apical insertion. Both of these techniques have disadvantages...... and are not conducive to repeated measurements. Therefore, the purpose of this study was to develop a new technique for measuring intracardiac hemodynamics....

  17. Disseminated intravascular and intracardiac thrombosis after cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2017-01-01

    Full Text Available Massive intracardiac and intravascular thrombosis is a rare complication following cardiopulmonary bypass (CPB. Most of the cases of the disseminated thrombosis have been reported in patients undergoing complex cardiac surgeries and those receiving antifibrinolytic agents during CPB. We report the occurrence of disseminated intravascular and intracardiac thrombosis after CPB in a patient undergoing mitral valve replacement in which no antifibrinolytic agent was used. The possible pathophysiology and management of the patient is discussed.

  18. Ventricular activity cancellation in electrograms during atrial fibrillation with constraints on residuals' power.

    Science.gov (United States)

    Corino, Valentina D A; Rivolta, Massimo W; Sassi, Roberto; Lombardi, Federico; Mainardi, Luca T

    2013-12-01

    During atrial fibrillation (AF), cancellation of ventricular activity from atrial electrograms (AEG) is commonly performed by template matching and subtraction (TMS): a running template, built in correspondence of QRSs, is subtracted from the AEG to uncover atrial activity (AA). However, TMS can produce poor cancellation, leaving high-power residues. In this study, we propose to modulate the templates before subtraction, in order to make the residuals as similar as possible to the nearby atrial activity, avoiding high-power ones. The coefficients used to modulate the template are estimated by maximizing, via Multi-swarm Particle Swarm Optimization, a fitness function. The modulated TMS method (mTMS) was tested on synthetic and real AEGs. Cancellation performances were assessed using: normalized mean squared error (NMSE, computed on simulated data only), reduction of ventricular activity (VDR), and percentage of segments (PP) whose power was outside the standard range of the atrial power. All testings suggested that mTMS is an improvement over TMS alone, being, on simulated data, NMSE and PP significantly decreased while VDR significantly increased. Similar results were obtained on real electrograms (median values of CS1 recordings PP: 2.44 vs. 0.38 p < 0.001; VDR: 6.71 vs. 8.15 p < 0.001). Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  20. Clinical evaluation of the use of an intracardiac electrocardiogram to guide the tip positioning of peripherally inserted central catheters.

    Science.gov (United States)

    Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang

    2016-06-01

    The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.

  1. Clinical application of low energy intracardiac cardioversion of atrial fibrillation

    International Nuclear Information System (INIS)

    Wu Liqun; Gu Gang; Su Kan; Su Renying; Shen Yongchu; Shen Weifeng

    2002-01-01

    Objective: To evaluate the efficacy and safety of low energy intracardiac cardioversion in persistent atria fibrillation. Methods: Low energy intracardiac cardioversion was performed by delivering R wave-synchronized biphasic shocks in 7 patients (4 men, 3 women) with persistent atrial fibrillation. Prior to the procedure, all patients underwent transesophageal echocardiographic examinations to rule out the presence of intracardiac thrombus and received subcutaneous injection of low molecular weight heparin for 3-5 days. Two custom-made 6 Fr catheters (Rhythm Technologies of Getz, USA) were used for de-fibrillation shock delivery. One catheter was positioned in the lower right atrium so that the majority of the catheter electrodes had firm contact with the right atrial free wall. The second catheter was placed randomly either in coronary sinus through right internal jugular vein or in the left pulmonary artery through femoral vein. In addition, a standard diagnostic 6-F quadrupolar catheter was placed at the right ventricular apex for ventricular synchronization and postshock ventricular pacing. Shocks were delivered by Implant Support Device (Model 4510, Teleceronics). After conversion, all patients were treated with intravenous amiodarone in the first 24 hours followed by oral administration. Results: In all 7 patients cardioversion of atrial fibrillation to sinus rhythm was successfully obtained. A mean of 2 ± 1 shocks per patient has been delivered with a total amount of 13 shocks. The average delivered energy was 7.8 ± 2.2 Joules. No complication occurred. At a mean follow-up of 18 ± 9 months, 4 of the 7 patients treated successfully showed sinus rhythm there after. Atrial fibrillation recurred in 3 patients at the second, fifth day and eighth month after cardioversion. Conclusions: Low energy intracardiac cardioversion is effective and safe, and can be easily performed in patients without general anesthesia. It offers a new option for restoring sinus

  2. A long slanted transseptal accessory pathway

    Directory of Open Access Journals (Sweden)

    Hui-Min Wang

    2011-05-01

    Full Text Available A 63-year-old male with Wolff-Parkinson-White syndrome was admitted for ablation of accessory pathway. Intracardiac electrogram revealed a left-side accessory pathway during tachycardia, which was successfully ablated from the right posterior tricuspid annulus because of a long slanted transseptal accessory pathway (2.2 cm.

  3. Cryoablation of Anteroseptal Accessory Pathways with a His Bundle Electrogram on the Ablation Catheter

    Directory of Open Access Journals (Sweden)

    Leonardo Liberman, MD

    2014-11-01

    Conclusions: In a small number of pediatric patients with AS AP with a His bundle electrogram seen on the ablation catheter, the use of cryotherapy was safe and effective for elimination of AP conduction without impairment of AV nodal conduction.

  4. Clinical and histologic effects of intracardiac administration of propofol for induction of anesthesia in ball pythons (Python regius).

    Science.gov (United States)

    McFadden, Michael S; Bennett, R Avery; Reavill, Drury R; Ragetly, Guillaume R; Clark-Price, Stuart C

    2011-09-15

    To assess the clinical differences between induction of anesthesia in ball pythons with intracardiac administration of propofol and induction with isoflurane in oxygen and to assess the histologic findings over time in hearts following intracardiac administration of propofol. Prospective randomized study. 30 hatchling ball pythons (Python regius). Anesthesia was induced with intracardiac administration of propofol (10 mg/kg [4.5 mg/lb]) in 18 ball pythons and with 5% isoflurane in oxygen in 12 ball pythons. Induction time, time of anesthesia, and recovery time were recorded. Hearts from snakes receiving intracardiac administration of propofol were evaluated histologically 3, 7, 14, 30, and 60 days following propofol administration. Induction time with intracardiac administration of propofol was significantly shorter than induction time with 5% isoflurane in oxygen. No significant differences were found in total anesthesia time. Recovery following intracardiac administration of propofol was significantly longer than recovery following induction of anesthesia with isoflurane in oxygen. Heart tissue evaluated histologically at 3, 7, and 14 days following intracardiac administration of propofol had mild inflammatory changes, and no histopathologic lesions were seen 30 and 60 days following propofol administration. Intracardiac injection of propofol in snakes is safe and provides a rapid induction of anesthesia but leads to prolonged recovery, compared with that following induction with isoflurane. Histopathologic lesions in heart tissues following intracardiac injection of propofol were mild and resolved after 14 days.

  5. Distribution, structure and projections of the frog intracardiac neurons.

    Science.gov (United States)

    Batulevicius, Darius; Skripkiene, Gertruda; Batuleviciene, Vaida; Skripka, Valdas; Dabuzinskiene, Anita; Pauza, Dainius H

    2012-05-21

    Histochemistry for acetylcholinesterase was used to determine the distribution of intracardiac neurons in the frog Rana temporaria. Seventy-nine intracardiac neurons from 13 frogs were labelled iontophoretically by the intracellular markers Alexa Fluor 568 and Lucifer Yellow CH to determine their structure and projections. Total neuronal number per frog heart was (Mean ± SE) 1374 ± 56. Largest collections of neurons were found in the interatrial septum (46%), atrioventricular junction (25%) and venal sinus (12%). Among the intracellularly labelled neurons, we found the cells of unipolar (71%), multipolar (20%) and bipolar (9%) types. Multiple processes originated from the neuron soma, hillock and proximal axon. These processes projected onto adjacent neuron somata and cardiac muscle fibers within the interatrial septum. Average total length of the processes from proximal axon was 348 ± 50 μm. Average total length of processes from soma and hillock was less, 118 ± 27 μm and 109 ± 24 μm, respectively. The somata of 59% of neurons had bubble- or flake-shaped extensions. Most neurons from the major nerves in the interatrial septum sent their axons towards the ventricle. In contrast, most neurons from the ventral part of the interatrial septum sent their axons towards the atria. Our findings contradict to a view that the frog intracardiac ganglia contain only non-dendritic neurons of the unipolar type. We conclude that the frog intracardiac neurons are structurally complex and diverse. This diversity may account for the complicated integrative functions of the frog intrinsic cardiac ganglia. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    Science.gov (United States)

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  7. A new approach to automated assessment of fractionation of endocardial electrograms during atrial fibrillation

    International Nuclear Information System (INIS)

    Křemen, V; Lhotská, L; Macaš, M; Čihák, R; Vančura, V; Kautzner, J; Wichterle, D

    2008-01-01

    Complex fractionated atrial electrograms (CFAEs) may represent the electrophysiological substrate for atrial fibrillation (AF). Progress in signal processing algorithms to identify sites of CFAEs is crucial for the development of AF ablation strategies. A novel algorithm for automated description of fractionation of atrial electrograms (A-EGMs) based on the wavelet transform has been proposed. The algorithm was developed and validated using a representative set of 1.5 s A-EGM (n = 113) ranked by three experts into four categories: 1—organized atrial activity; 2—mild; 3—intermediate; 4—high degree of fractionation. A tight relationship between a fractionation index and expert classification of A-EGMs (Spearman correlation ρ = 0.87) was documented with a sensitivity of 82% and specificity of 90% for the identification of highly fractionated A-EGMs. This operator-independent description of A-EGM complexity may be easily incorporated into mapping systems to facilitate CFAE identification and to guide AF substrate ablation

  8. Segmenting high-frequency intracardiac ultrasound images of myocardium into infarcted, ischemic, and normal regions.

    Science.gov (United States)

    Hao, X; Bruce, C J; Pislaru, C; Greenleaf, J F

    2001-12-01

    Segmenting abnormal from normal myocardium using high-frequency intracardiac echocardiography (ICE) images presents new challenges for image processing. Gray-level intensity and texture features of ICE images of myocardium with the same structural/perfusion properties differ. This significant limitation conflicts with the fundamental assumption on which existing segmentation techniques are based. This paper describes a new seeded region growing method to overcome the limitations of the existing segmentation techniques. Three criteria are used for region growing control: 1) Each pixel is merged into the globally closest region in the multifeature space. 2) "Geographic similarity" is introduced to overcome the problem that myocardial tissue, despite having the same property (i.e., perfusion status), may be segmented into several different regions using existing segmentation methods. 3) "Equal opportunity competence" criterion is employed making results independent of processing order. This novel segmentation method is applied to in vivo intracardiac ultrasound images using pathology as the reference method for the ground truth. The corresponding results demonstrate that this method is reliable and effective.

  9. Detection of intra-cardiac and intra-arterial thrombi using labelled platelets

    International Nuclear Information System (INIS)

    Bernard, P.J.; Laforte, C. de

    1990-01-01

    Scintigraphy with 111 Indium labelled platelets is a powerful tool to detect platelet deposits in vessels. This quantitative and functional imaging method needs a labeling procedure which completely preserves the properties of the platelets and allows the concept of hematologically active clot. Three main groups of patients were examined. 1-91 hematologically active intra-cardiac thrombi were detected. The follow-up of 19 of them shows 5 deaths and 7 cerebral embolisms. 2-372 patients with lower limb ischemia, mainly in the case of blue toe syndrome were examined. 158 times a comparison with the surgical patterns was possible, there were 3 false positive and 9 false negative results. 3-In a group of 310 patients with transient cerebro-vascular accidents, 38 times the records were poorly significant. In 27 patients we were able to compare the morphological examinations (including platelet scintigraphy) to the anatomical findings. Sensitivity was only 64% and specificity 71%. As in the cases of intra-cardiac thrombi, the method allows the follow-up of pharmacological therapy. Platelets labelled with 111 Indium provide the means for sensitive and specific detection of hematologically active clots in cardiac and arterial pathology [fr

  10. Efficient computation of electrograms and ECGs in human whole heart simulations using a reaction-eikonal model.

    Science.gov (United States)

    Neic, Aurel; Campos, Fernando O; Prassl, Anton J; Niederer, Steven A; Bishop, Martin J; Vigmond, Edward J; Plank, Gernot

    2017-10-01

    Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.

  11. Detection of intracardiac shunts with contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Manning, W.J.; Atkinson, D.J.; Parker, J.A.; Edelman, R.R.

    1990-01-01

    This paper reports on ultrafast MR imaging with bolus administration of Gd-DTPA used to detect intracardiac shunts. Ten patients who had recently undergone cardiac catheterization or first-pass radionuclide evaluation were selected for study. These included five patients without intracardiac shunts and five patients with shunts (three with atrial septal defect, two with ventricular septal defect). Resting four-chamber cardiac images were obtained during intravenous injection of Gd-DTPA (0.02 mmol/kg) with an ultrafast, T1-weighted sequence. Images were acquired over 380 msec, with repetitive images obtained with each QRS for 50 beats. In addition, standard MR cine examinations were performed

  12. Intracardiac heterotopia--mesenchymal and endodermal.

    Science.gov (United States)

    Ariza, S; Rafel, E; Castillo, J A; Garcia-Canton, J A

    1978-01-01

    A case is reported of an intracardiac 'epithelial heterotopia' with a predominant mesenchymal component. This is thought to have resulted from the differentiation of aberrant primitive cell(s) displaced into the heart during its development. Though microscopically resembling a myxoma, this lesion is clearly distinguished by the presence of glandular structures. The myxoid component exhibited a startling invasiveness which resulted in occlusion of the superior vena cava, causing symptoms very early in life and death at the age of 6 months. Images PMID:637987

  13. Detection of intracardiac thrombi by scintiphotography with 111In-labeled autologous platelets

    International Nuclear Information System (INIS)

    Yui, Tokuo; Uchida, Tatsumi; Matsuda, Shin

    1982-01-01

    Detection of intracardiac thrombi by scintigraphy with In-111-oxine labeled autologous platelets was studied in 14 patients with various heart diseases. The results of platelet scintigraphy were compared with those of two dimensional echocardiography. In 4 of the 14 patients, the findings on platelet scintigraphy and echocardiography were both positive. Left atrial thrombi were detected in 3 patients with mitral valve disease (MVD), and left ventricular thrombus in a patient with myocardial infarction with left ventricular aneurysm (MI). The scintigraphy after antiplatelet therapy in the patient with MI did not show any radioactivity on the thrombus. In one of the 14 patients with MVD, the finding on platelet scintigraphy was positive, on the other hand echocardiography was negative. In one of the 14 patients with MVD, the finding on platelet scintigraphy was negative, on the other hand that on echocardiography was positive. The thrombus in this case may be hematologically nonactive thrombus. In-111 platelet scintigraphy is considered to be an excellent method for the diagnosis and in vivo assessment of antithrombotic therapy on intracardiac thrombosis. (J.P.N.)

  14. Discrete potentials guided radiofrequency ablation for idiopathic outflow tract ventricular arrhythmias.

    Science.gov (United States)

    Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping

    2015-03-01

    Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  15. Systemic and intracardiac hemodynamic disturbance in complicated forms of hepatocirrhosis

    International Nuclear Information System (INIS)

    Mjasnik, B.N.; Chodzibekov, M.C.; Achmedzanova, S.S.

    1990-01-01

    On the base of radionuclide investigation of systemic and intracardiac hemodynamics was shown that the rate of kinetic variants of hemocirculation does not depend on the stage of portal hypertension in complicated forms of hepatocirrhosis. Blood redistribution in these patients creates volumentrical overload of cardiac ventricles and pulmonary circulation, that is conditioned of additional tension of cardiac muscle and especially of right ventricle myocardium, which reserve rapidly ran out. Operations which increase blood shunt from portal system to superior vena cava raise preload of myocardium that makes the high risk in appearance of cardiac insufficiency, especially of right ventricle in early post operative period. The received data indicated on necessity to take into account the state of intracardiac hemodynamics in selection of surgical approach in patients with complicated forms of hepatocirrhosis. (orig.) [de

  16. Identification of intracardiac thrombi in stroke patients with indium-111 platelet scintigraphy

    International Nuclear Information System (INIS)

    Kessler, C.; Henningsen, H.; Reuther, R.; Kimmig, B.; Roesch, M.

    1987-01-01

    Platelet scintigraphy (PSC) with indium-111 labelled platelets has been confirmed as an adequate method for the detection of intracardiac thrombi in patients with heart disease. We performed PSC of the heart and the neck vessels in 27 stroke patients with suspected cardiac embolism and as control on 10 patients with atherosclerotic lesions of the carotid arteries without evidence of heart disease. The carotid PSC was positive in 6 of 10 patients with carotid disease, and twice in the 27 with suspected cardiac embolism. In these 27 the PSC of the heart indicated pathological conditions 13 times. Pathological platelet accumulations could be visualized in 3 cases in the atrial space, in 9 cases in the region of the left ventricle, and once at the aortic valve. Scintigraphy was negative in all 10 patients with atherosclerosis of the neck vessels. The two-dimensional echocardiography revealed pathological findings in 8 of the 13 patients with positive heart PSC (3 with intraventricular thrombi, 3 with valvular disease, 2 with decreased ventricular contractility) and was normal in the 10 control patients. Open-heart surgery was performed in 2 patients with pathological PSC and revealed an intracardiac thrombus. Three of 4 patients with positive atrial PSC showed mitral or aortic valve disease. These results suggest that PSC can provide a valuable method for detecting cardiac thrombi in stroke patients

  17. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake and others

    1988-12-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69+-0.48 to 0.11+-0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07+-1.03) were not significantly different from those at the first scintigraphy (1.13+-0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy.

  18. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    International Nuclear Information System (INIS)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake

    1988-01-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69±0.48 to 0.11±0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07±1.03) were not significantly different from those at the first scintigraphy (1.13±0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy. (author)

  19. Intracardiac thrombus in Behçet's disease: Two case reports

    Directory of Open Access Journals (Sweden)

    Brahem Radhia

    2005-07-01

    Full Text Available Abstract Intracardiac thrombus in Behçet's disease is an extremely rare manifestation. We report two such cases. A 20-year-old man presented with dyspnoea, cough and haemoptysis. Right heart thrombus associated with pulmonary artery aneurysm and thromboembolism was identified by helical CT and transoesophageal echocardiography. The second case was a 29-year-old male admitted for fever and chest pain. A diagnosis of right atrial thrombosis associated with pulmonary embolism and hyperhomocysteinemia was made. Due to the absence of haemodynamic compromise, medical management consisting of immunosupressive and anticoagulation therapy was adopted which resulted in complete dissolution of the thrombus with dramatic clinical improvement in both cases of clinical status. Conclusion intracardiac thrombus is a rare complication of Behçet's disease. As shown in our patients, medical treatment should be considered as the first line.

  20. Intracardiac impedance response during acute AF internal cardioversion using novel rectilinear and capacitor-discharge waveforms.

    Science.gov (United States)

    Rababah, A S; Walsh, S J; Manoharan, G; Walsh, P R; Escalona, O J

    2016-07-01

    Intracardiac impedance (ICI) is a major determinant of success during internal cardioversion of atrial fibrillation (AF). However, there have been few studies that have examined the dynamic behaviour of atrial impedance during internal cardioversion in relation to clinical outcome. In this study, voltage and current waveforms captured during internal cardioversion of acute AF in ovine models using novel radiofrequency (RF) generated low-tilt rectilinear and conventional capacitor-discharge based shock waveforms were retrospectively analysed using a digital signal processing algorithm to investigate the dynamic behaviour of atrial impedance during cardioversion. The algorithm was specifically designed to facilitate the simultaneous analysis of multiple impedance parameters, including: mean intracardiac impedance (Z M), intracardiac impedance variance (ICIV) and impedance amplitude spectrum area (IAMSA) for each cardioversion event. A significant reduction in ICI was observed when comparing two successive shocks of increasing energy where cardioversion outcome was successful. In addition, ICIV and IAMSA variables were found to inversely correlate to the magnitude of energy delivered; with a stronger correlation found to the former parameter. In conclusion, ICIV and IAMSA have been evidenced as two key dynamic intracardiac impedance variables that may prove useful in better understanding of the cardioversion process and that could potentially act as prognostic markers with respect to clinical outcome.

  1. Anatomical Evidence for Intracardiac Blood Shunting in Marine Turtles

    African Journals Online (AJOL)

    ... suggests that right to left intra-cardiac blood shunts may be a feature of diving in sea turtles; the sphincter providing a mechanism for the control of blood flow through the heart. The comparative anatomy of the pulmonary arteries of selected terrestrial reptiles suggests that a similar mechanism exists in non-diving species.

  2. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Atrial electrogram interpretation improves after an innovative education program.

    Science.gov (United States)

    Preston, Julie L; Currey, Judy; Considine, Julie

    2015-01-01

    To avoid adverse patient outcomes from inappropriate treatment, it is recommended that an atrial electrogram (AEG) be recorded whenever atrial arrhythmias develop in patients after cardiac surgery. However, AEGs are not commonly performed because nurses lack knowledge about differentiating atrial rhythms on AEGs. To investigate whether completing a novel online evidence-based education program on interpreting AEGs would improve critical care nurses' AEG interpretation. Specialized critical care nurses were taught about obtaining and interpreting atrial rhythms on AEGs using a 42-minute online mini-movie. AEG interpretation was assessed pre and two and eight weeks post-intervention. AEG interpretation increased two weeks post intervention and was retained at eight weeks. Some participants used this newly acquired knowledge to interpret arrhythmias that were not taught during the education program. Accurate interpretation of AEGs is an easy skill for specialized critical care nurses to learn via an online education program.

  4. Detecting phase singularities and rotor center trajectories based on the Hilbert transform of intraatrial electrograms in an atrial voxel model

    Directory of Open Access Journals (Sweden)

    Unger Laura Anna

    2015-09-01

    Full Text Available This work aimed at the detection of rotor centers within the atrial cavity during atrial fibrillation on the basis of phase singularities. A voxel based method was established which employs the Hilbert transform and the phase of unipolar electrograms. The method provides a 3D overview of phase singularities at the endocardial surface and within the blood volume. Mapping those phase singularities from the inside of the atria at the endocardium yielded rotor center trajectories. We discuss the results for an unstable and a more stable rotor. The side length of the areas covered by the trajectories varied from 1.5 mm to 10 mm. These results are important for cardiologists who target rotors with RF ablation in order to cure atrial fibrillation.

  5. Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein׳s anomaly

    Directory of Open Access Journals (Sweden)

    Akira Shimane, MD

    2014-12-01

    Full Text Available We report a case of Ebstein׳s anomaly in which radiofrequency catheter ablation of an accessory pathway was successfully performed under intra-cardiac echocardiography. A 50-year-old woman was referred to our hospital for radiofrequency catheter ablation of a paroxysmal supraventricular tachycardia. A 12-lead surface electrocardiogram revealed ventricular pre-excitation associated with type B Wolff–Parkinson–White syndrome. In the baseline electrophysiological study, an orthodromic atrioventricular reciprocating tachycardia with a right posterior accessory pathway was induced. A phased-array intra-cardiac echo probe was positioned in the right atrium to visualize the atrioventricular junction. The key structures for catheter ablation, such as the atrialized right ventricle, atrioventricular junction, and tricuspid valve, were clearly visualized on intra-cardiac echocardiography. Radiofrequency current was successfully delivered at the atrioventricular junction, where a Kent potential was recorded. During a 6-month follow-up period, the patient was free from arrhythmias. The findings in this case suggest that phased-array intra-cardiac echocardiography is useful for ablation of right-sided accessory pathways in patients with Ebstein׳s anomaly.

  6. Intracardiac Thrombosis during Adult Liver Transplantation

    Directory of Open Access Journals (Sweden)

    Marina Moguilevitch

    2013-01-01

    Full Text Available Intracardiac thrombosis (ICT and pulmonary embolism (PE during adult liver transplantation are rare but potentially lethal complications. They are often overlooked because of significant diagnostic challenges. The combination of hemodynamic compromise and transesophageal echocardiography (TEE findings allows for correct diagnosis. A large variety of putative risk factors for ICT and PE have been suggested, but these events are considered to be multifactorial. There are different proposed treatment modalities for these devastating complications. Unfortunately, in spite of growing knowledge in this area, intraoperative and postoperative mortalities remain very high. The retrospective nature of the study of these events makes the case reports extremely valuable.

  7. Automatic detection and classification of human epicardial atrial unipolar electrograms

    International Nuclear Information System (INIS)

    Dubé, B; Vinet, A; Xiong, F; Yin, Y; LeBlanc, A-R; Pagé, P

    2009-01-01

    This paper describes an unsupervised signal processing method applied to three-channel unipolar electrograms recorded from human atria. These were obtained by epicardial wires sutured on the right and left atria after coronary artery bypass surgery. Atrial (A) and ventricular (V) activations had to be detected and identified on each channel, and gathered across the channels when belonging to the same global event. The algorithm was developed and optimized on a training set of 19 recordings of 5 min. It was assessed on twenty-seven 2 h recordings taken just before the onset of a prolonged atrial fibrillation for a total of 1593697 activations that were validated and classified as normal atrial or ventricular activations (A, V) and premature atrial or ventricular activations (PAA, PVA). 99.93% of the activations were detected, and amongst these, 99.89% of the A and 99.75% of the V activations were correctly labelled. In the subset of the 39705 PAA, 99.83% were detected and 99.3% were correctly classified as A. The false positive rate was 0.37%. In conclusion, a reliable fully automatic detection and classification algorithm was developed that can detect and discriminate A and V activations from atrial recordings. It can provide the time series needed to develop a monitoring system aiming to identify dynamic predictors of forthcoming cardiac events such as postoperative atrial fibrillation

  8. Spiral wave classification using normalized compression distance: Towards atrial tissue spatiotemporal electrophysiological behavior characterization.

    Science.gov (United States)

    Alagoz, Celal; Guez, Allon; Cohen, Andrew; Bullinga, John R

    2015-08-01

    Analysis of electrical activation patterns such as re-entries during atrial fibrillation (Afib) is crucial in understanding arrhythmic mechanisms and assessment of diagnostic measures. Spiral waves are a phenomena that provide intuitive basis for re-entries occurring in cardiac tissue. Distinct spiral wave behaviors such as stable spiral waves, meandering spiral waves, and spiral wave break-up may have distinct electrogram manifestations on a mapping catheter. Hence, it is desirable to have an automated classification of spiral wave behavior based on catheter recordings for a qualitative characterization of spatiotemporal electrophysiological activity on atrial tissue. In this study, we propose a method for classification of spatiotemporal characteristics of simulated atrial activation patterns in terms of distinct spiral wave behaviors during Afib using two different techniques: normalized compressed distance (NCD) and normalized FFT (NFFTD). We use a phenomenological model for cardiac electrical propagation to produce various simulated spiral wave behaviors on a 2D grid and labeled them as stable, meandering, or breakup. By mimicking commonly used catheter types, a star shaped and a circular shaped both of which do the local readings from atrial wall, monopolar and bipolar intracardiac electrograms are simulated. Virtual catheters are positioned at different locations on the grid. The classification performance for different catheter locations, types and for monopolar or bipolar readings were also compared. We observed that the performance for each case differed slightly. However, we found that NCD performance is superior to NFFTD. Through the simulation study, we showed the theoretical validation of the proposed method. Our findings suggest that a qualitative wavefront activation pattern can be assessed during Afib without the need for highly invasive mapping techniques such as multisite simultaneous electrogram recordings.

  9. Assessment of ventricular excitation propagation velocity using intramyocardial electrograms and electron beam tomography images

    International Nuclear Information System (INIS)

    Kraft, A.; Schreier, G.; Hutten, H.; Kastner, P.; Rienmueller, R.; Grasser, B; Iberer, F.; Tscheliessnigg, K.H.

    1999-01-01

    The combination of intramyocardial electrogram (IEGM) recordings and 3D-reconstruction of the heart allows to relate electrophysiological with geometrical parameters of the heart. In 12 Heart transplants the distance of two epimyocardially implanted pacemaker leads d x and the propagation time f x have been correlated. Linear regression analysis revealed significant (p < 0,002) and strong (r = 0,82) correlation. The ventricular excitation propagation velocity (VEPV) within the examined patient group was found to be 0,53 m/s with an offset of 14.25 mm, which is caused by the extent of the electrodes and the region of early capture immediately after stimulation. (author)

  10. A Case of Myopathy, Encephalopathy, Lactic Acidosis and Stroke-Like Episodes (MELAS) Syndrome with Intracardiac Thrombus [corrected].

    Science.gov (United States)

    Joo, Jung-Chul; Seol, Myung Do; Yoon, Jin Won; Lee, Young Soo; Kim, Dong-Keun; Choi, Yong Hoon; Ahn, Hyo Seong; Cho, Wook Hyun

    2013-03-01

    Myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) is a multisystem clinical syndrome manifested by mitochondrial myopathy, encephalopathy, lactic acidosis and recurrent stroke-like episodes. A 27-year-old female with MELAS syndrome presented with cerebral infarction. Echocardiography revealed a thrombus attached to the apex of the hypertrophied left ventricle, with decreased systolic function. The embolism of the intracardiac thrombus might have been the cause of stroke. There should be more consideration given to the increased possibility of intracardiac thrombus formation when a MELAS patient with cardiac involvement is encountered.

  11. Detection of intracardiac thrombi by 111In-oxine platelet imaging

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hayashi, Makoto; Hayashida, Kohei; Uehara, Toshiisa; Naito, Hiroaki; Kozuka, Takahiro; Boku, Eidai; Sakakibara, Hiroshi

    1985-01-01

    111 In-oxine platelet imaging (RI) was undertaken in 55 patients with suspected intracardiac thrombi. The results were compared with those from echocardiography (US) and computed tomography (CT). Sensitivity and specificity of RI were 71 % and 92 %, respectively. Visualizing thrombi on RI was seen in 10 (56 %) of 18 patients receiving anticoagulant therapy such as Warfarin (Group A) and in 12 (92 %) of 13 patients without it (Group B). This implied that active platelet deposition is inhibited by giving Warfarin. Regarding the size of thrombi, three methods showed the same size in 11 (85 %) of Group B. RI showed smaller thrombi than US and CT in 7 (39 %) of Group A, and failed to reveal them in 8 (44 %). Unlike morphological diagnosis by US and CT, RI proved to be of value in the evaluation of the activity of platelets (platelet deposition on the surface of thrombus). This method can also be used in the evaluation of thrombogenity. (Namekawa, K.)

  12. An international multicenter study comparing arrhythmia prevalence between the intracardiac lateral tunnel and the extracardiac conduit type of Fontan operations.

    Science.gov (United States)

    Balaji, Seshadri; Daga, Ankana; Bradley, David J; Etheridge, Susan P; Law, Ian H; Batra, Anjan S; Sanatani, Shubayan; Singh, Anoop K; Gajewski, Kelly K; Tsao, Sabrina; Singh, Harinder R; Tisma-Dupanovic, Svjetlana; Tateno, Shigeru; Takamuro, Motoki; Nakajima, Hiromichi; Roos-Hesselink, Jolien W; Shah, Maully

    2014-08-01

    The study objective was to determine whether the extracardiac conduit Fontan confers an arrhythmia advantage over the intracardiac lateral tunnel Fontan. This multicenter study of 1271 patients compared bradyarrhythmia (defined as need for pacing) and tachyarrhythmia (defined as needing antiarrhythmic therapy) between 602 patients undergoing the intracardiac Fontan and 669 patients undergoing the extracardiac Fontan. The median age at the time of the Fontan procedure was 2.1 years (interquartile range, 1.6-3.2 years) for the intracardiac group and 3.0 years (interquartile range, 2.4-3.9) for the extracardiac group (P 30 days) bradyarrhythmia occurred in 105 patients (18%) in the intracardiac group and 63 patients (9%) in the extracardiac group (P 30 days) tachyarrhythmia occurred in 58 patients (10%) in the intracardiac group and 23 patients (3%) in the extracardiac group (P factoring time since surgery, more patients in the extracardiac group had early bradycardia (odds ratio, 2.9; 95% confidence interval, 1.8-4.6), with no difference in early tachycardia, late bradycardia, or late tachycardia. Overall arrhythmia burden is similar between the 2 groups, but the extracardiac Fontan group had a higher incidence of early bradyarrhythmias. There was no difference in the incidence of late tachyarrhythmias over time between the 2 operations. Therefore, the type of Fontan performed should be based on factors other than an anticipated reduction in arrhythmia burden from the extracardiac conduit. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. Intracardiac Echocardiography Evaluation in Secundum Atrial Septal Defect Transcatheter Closure

    International Nuclear Information System (INIS)

    Zanchetta, Mario; Pedon, Luigi; Rigatelli, Gianluca; Carrozza, Antonio; Zennaro, Marco; Di Martino, Roberta; Onorato, Eustaquio; Maiolino, Pietro

    2003-01-01

    Purpose: This study was designed to assess the balloon sizing maneuvers and deployment of an Amplatzer Septal Occluder (ASO). In addition, intraprocedural balloon sizing was compared with off-line intracardiac echocardiographic measurements. Methods: The intracardiac echocardiography (ICE) measurements were: maximum transverse and longitudinal atrial septal defect (ASD) diameters in the aortic valve and four-chamber planes;area of the ASD and its equivalent circle diameter. Thirteen consecutive patients underwent transcatheter implantation of an ASO device using ICE guidance under local anesthesia. The device matching the balloon sizing diameter of the defect was implanted. Qualitative ICE assessment of the ASO devices implanted was performed off line. Results: The mean equivalent circle diameter predicted by ICE was 24.40 ± 5.61 mm and was significantly higher(p 0.027) than the ASD measured by balloonsizing (21.38 ± 5.28 mm). Unlike previous studies we did not find any correlation between the two measurements (correlation coefficient = 0.47). Only four of the 13 patients had optimal device positioning as shown by the qualitative ICE evaluation, whereas the remaining nine patients had inadequate device placement. This resulted in a waist diameter that was an average 26.1% undersized in seven patients and 12.7% oversized in two patients. Five of the seven patients with an undersized device had ASO-atrial septum misalignment with leftward device deviation. Conclusion: The ICE images allowed careful measurement of the dimensions of the ASD and accurately displayed the spatial relations of the ASO astride the ASD.Moreover, use of the ICE measurement led to selection of a different size of device in comparison with those of balloon sizing. The clinical benefit of this new approach needs to be rigorously tested

  14. An unexpected complication of acute pancreatitis: Intra-cardiac thrombus.

    Science.gov (United States)

    Keskin, Muhammed; Gümüşdağ, Ayça; Börklü, Edibe Betül; Dayı, Şennur Ünal; Avcı, İlhan İlker; Güvenç, Tolga Sinan; Güngör, Barış; Karabay, Can Yücel; Kozan, Ömer

    2017-05-01

    Left atrial thrombus after acute pancreatitis (AP) is a rare clinical statement. Because of induction of systemic prothrombotic process by AP; some patients with underlying risk factors may develop an intra-cardiac thrombus. We present a 53years-old-woman with moderate mitral stenosis and atrial fibrillation. However the patient was under warfarin treatment, she developed a big left atrial big thrombus which was originated from left atrial appendage after she was suffered from AP. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Intracardiac thrombus in Behçet’s disease

    Directory of Open Access Journals (Sweden)

    I. Ben Ghorbel

    2016-12-01

    Full Text Available Behçet’s disease (BD is a multisystem inflammatory disorder. Intracardiac thrombus (ICT formation is an uncommon but important complication of BD. Of the cases of Behçet’s disease, we selected those with ICT. All patients fulfilled the diagnostic criteria of the International Study Group of Behçet’s disease. The ICT in each case was confirmed by ultrasonography, computed tomography and MRI. Clinical features and laboratory parameters were determined. Among our 518 patients with BD, 8 were diagnosed as having intracardiac thrombus (ICT. All were male; the mean age at the time of the ICT diagnosis was 30.8 years. The main presenting symptoms were hemoptysis, chest pain, and dyspnea. It was associated with pulmonary artery aneurysm and vena cava thrombosis in 3 cases each, pulmonary embolism, and lower limbs deep venous thrombosis in 1 case each. The coexistence of other cardiac complications was as follows: pericarditis in 2 cases, myocarditis, endomyocardial fibrosis, and coronary arteritis with consequent myocardial infarction in one case each. In all cases, echocardiography was sufficient to reach the diagnosis. Chest computed tomography performed in all cases led to the diagnosis of associated pulmonary vasculo-Behçet lesions in 4 cases. All patients received colchicine, anticoagulation, and corticosteroids. Seven patients were on immunosuppressant agents (2 patients received azathioprine and 5 cyclophosphamide. Clinical remission with ICT resolution was observed in 5 cases. Combined immunosuppressive therapy with prednisone and cyclophosphamide might be needed to treat ICT due to BD.

  16. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  17. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....

  18. Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: A pilot study.

    Science.gov (United States)

    Stopyra, Jason P; Winslow, James E; Fitzgerald, David M; Bozeman, William P

    2017-11-01

    Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead. Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed. A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices. In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette. Copyright © 2017. Published by Elsevier Ltd.

  19. Electromagnetic Interference from Swimming Pool Generator Current Causing Inappropriate ICD Discharges

    Directory of Open Access Journals (Sweden)

    Edward Samuel Roberto

    2017-01-01

    Full Text Available Electromagnetic interference (EMI includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation. This is a unique case of extracardiac EMI by alternating current leakage from a submerged motor used to recycle chlorinated water, resulting in false rhythm detection and inappropriate ICD discharge. A 31-year-old female with arrhythmogenic right ventricular cardiomyopathy and Medtronic dual-chamber ICD placement presented after several inappropriate ICD shocks at the public swimming pool. Patient had never received prior shocks and device was appropriate at all regular follow-ups. Intracardiac electrograms revealed unique, high-frequency signals at exactly 120 msec suggestive of EMI from a strong external source of alternating current. Electrical artifact was incorrectly sensed as a ventricular arrhythmia which resulted in discharge. ICD parameters including sensing, pacing thresholds, and impedance were all normal suggesting against device malfunction. With device failure and intracardiac sources excluded, EMI was therefore strongly suspected. Avoidance of EMI source brought complete resolution with no further inappropriate shocks. After exclusion of intracardiac interference, device malfunction, and abnormal settings, extracardiac etiologies such as EMI must be thoughtfully considered and excluded. Elimination of inappropriate shocks is to “first, do no harm.”

  20. A Bone Metastasis Nude Mouse Model Created by Ultrasound Guided Intracardiac Injection of Breast Cancer Cells: the Micro-CT, MRI and Bioluminescence Imaging Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Jin; Song, Eun Hye; Kim, Seol Hwa; Song, Ho Taek; Suh, Jin Suck [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Sang Hyun [Korean Minjok Leadership Academy, Heongsung (Korea, Republic of)

    2011-01-15

    The purpose of this study was to develop a nude mouse model of bone metastasis by performing intracardiac injection of breast cancer cells under ultrasonography guidance and we wanted to evaluate the development and the distribution of metastasis in vivo using micro-CT, MRI and bioluminescence imaging. Animal experiments were performed in 6-week-old female nude mice. The animals underwent left ventricular injection of 2x105 MDA-MB-231Bo-Luc cells. After injection of the tumor cells, serial bioluminescence imaging was performed for 7 weeks. The findings of micro-CT, MRI and the histology were correlated with the 'hot' lesions seen on the bioluminescence imaging. Metastasis was found in 62.3% of the animals. Two weeks after intracardiac injection, metastasis to the brain, spine and femur was detected with bioluminescence imaging with an increasing intensity by week 7. Micro-CT scan confirmed multiple osteolytic lesions at the femur, spine and skull. MRI and the histology were able to show metastasis in the brain and extraskeletal metastasis around the femur. The intracardiac injection of cancer cells under ultrasonography guidance is a safe and highly reproducible method to produce bone metastasis in nude mice. This bone metastasis nude mouse model will be useful to study the mechanism of bone metastasis and to validate new therapeutics

  1. The Role of Echocardiography and Intracardiac Exploration in the Evaluation of Candidacy for Biventricular Repair in Patients With Borderline Left Heart Structures.

    Science.gov (United States)

    Mery, Carlos M; Nieto, R Michael; De León, Luis E; Morris, Shaine A; Zhang, Wei; Colquitt, John L; Adachi, Iki; Kane, Lauren C; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2017-03-01

    Predictors for single ventricle palliation (SVP) or successful biventricular repair (BVR) in patients with borderline left-side heart structures are not well defined. The goal was to evaluate the role of echocardiography and intracardiac exploration in determining feasibility of BVR. All neonates surgically treated from 1995 to 2015 with mitral valve (MV), aortic valve, or left ventricle end-diastolic dimension z score of -2 or less for whom management was controversial were included. Data were analyzed using Fisher's exact test, Kruskal-Wallis test, and Kaplan-Meier analysis. The cohort consisted of 42 patients: 7 SVP (17%) and 35 BVR (83%). Median follow-up was 7 years (range, 6 months to 18 years). Intracardiac exploration was performed in 29 patients (69%). There was poor correlation between echocardiographic and intraoperative MV measurements (intraclass correlation coefficient 0.14). Preoperative echocardiography significantly underestimated MV size in 14 patients (54%). Two BVR patients were converted to SVP, and 4 (including 1 converted patient) had cardiac-related deaths. All patients with MV greater than 8 mm on preoperative echocardiography had successful BVR. An intraoperative MV less than 8 mm and an abnormal subvalvar apparatus was present in 5 of 6 SVP (83%) and 3 of 3 (100%) failed BVR patients who had intracardiac exploration, and in only 1 of 20 successful BVR patients (5%) who had an intracardiac exploration. The decision to proceed to BVR in patients with borderline left-side heart structures should not rely strictly on echocardiographic measurements. Intracardiac exploration of the MV and subvalvar apparatus is useful before committing a patient to SVP. Patients with low MV z scores, especially those with a normal subvalvar apparatus, may undergo BVR with good outcomes. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Intracardiac tumor: A risk factor for stroke in the young –A case report

    African Journals Online (AJOL)

    Intracardiac mass should be considered a possible risk factor for ischemic stroke in young adult, especially in the absence of other risk factors such as connective tissue disorders, HIV/AIDS, hemoglobinopathy or use of recreational drugs. High index of suspicion is required in order not to overlook such source of emboli.

  3. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    Science.gov (United States)

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  4. Intracardiac Low-grade Sarcoma Following Treatment for Ewing Sarcoma.

    Science.gov (United States)

    Ortiz, Michael V; Magnan, Heather; Slotkin, Emily K; Ambati, Srikanth R; Chou, Alexander J; Wexler, Leonard H; Meyers, Paul A; Walsh, Michael F; Heaton, Todd; Girardi, Leonard N; Wolden, Suzanne L; Price, Anita P; Kennedy, Jennifer A; Zehir, Ahmet; Hameed, Meera; Berger, Michael F; Kentsis, Alex; Shukla, Neerav

    2017-11-01

    A 16-year-old male was diagnosed with Ewing sarcoma of the ribcage with pulmonary metastases. Six months after completion of scheduled therapy, he was found to have a new intracardiac mass, presumed recurrent Ewing sarcoma. EWSR1 fusion was not detected by droplet digital polymerase chain reaction from blood plasma. After no improvement with salvage chemotherapy, he underwent surgical resection that identified a low-grade spindle cell sarcoma. Despite the near-synchronous presentation of 2 unrelated sarcomas, extensive genomic analyses did not reveal any unifying somatic or germline mutations nor any apparent cancer predisposition. This case also highlights the potential role of utilizing plasma cell-free DNA for diagnosing tumors in locations where biopsy confers high morbidity.

  5. Real-Time Rotational Activity Detection in Atrial Fibrillation

    Science.gov (United States)

    Ríos-Muñoz, Gonzalo R.; Arenal, Ángel; Artés-Rodríguez, Antonio

    2018-01-01

    Rotational activations, or spiral waves, are one of the proposed mechanisms for atrial fibrillation (AF) maintenance. We present a system for assessing the presence of rotational activity from intracardiac electrograms (EGMs). Our system is able to operate in real-time with multi-electrode catheters of different topologies in contact with the atrial wall, and it is based on new local activation time (LAT) estimation and rotational activity detection methods. The EGM LAT estimation method is based on the identification of the highest sustained negative slope of unipolar signals. The method is implemented as a linear filter whose output is interpolated on a regular grid to match any catheter topology. Its operation is illustrated on selected signals and compared to the classical Hilbert-Transform-based phase analysis. After the estimation of the LAT on the regular grid, the detection of rotational activity in the atrium is done by a novel method based on the optical flow of the wavefront dynamics, and a rotation pattern match. The methods have been validated using in silico and real AF signals. PMID:29593566

  6. Intracardiac Echocardiography Guided Transeptal Catheter Injection of Microspheres for Assessment of Cerebral Microcirculation in Experimental Models

    Directory of Open Access Journals (Sweden)

    Judith Bellapart

    2013-01-01

    Full Text Available The use of microspheres for the determination of regional microvascular blood flow (RMBF has previously used different approaches. This study presents for the first time the intracardiac injection of microspheres using transeptal puncture under intracardiac echocardiography guidance. Five Merino sheep were instrumented and cardiovascularly supported according to local guidelines. Two catheter sheaths into the internal jugular vein facilitated the introduction of an intracardiac probe and transeptal catheter, respectively. Five million colour coded microspheres were injected into the left atrium via this catheter. After euthanasia the brain was used as proof of principle and the endpoint for determination of microcirculation at different time points. Homogeneous allocation of microspheres to different regions of the brain was found over time. Alternate slices from both hemispheres showed the following flow ranges: for slice 02; 0.57–1.02 mL/min/g, slice 04; 0.45–1.42 mL/min/g, slice 06; 0.35–1.87 mL/min/g, slice 08; 0.46–1.77 mL/min/g, slice 10; 0.34–1.28 mL/min/g. A mixed effect regression model demonstrated that the confidence interval did include zero suggesting that the apparent variability intra- and intersubject was not statistically significant, supporting the stability and reproducibility of the injection technique. This study demonstrates the feasibility of the transeptal injection of microspheres, showing a homogeneous distribution of blood flow through the brain unchanged over time and has established a new interventional model for the measurement of RMBF in ovine models.

  7. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    Science.gov (United States)

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  8. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  9. Diagnostic dilemma: Intracardiac mass in a woman with Behçet's syndrome.

    Science.gov (United States)

    Núñez-Cabarcas, Edilberto; López-Ruiz, Nilson; Ramírez-Rincón, Alex

    2014-01-01

    Intracardiac thrombosis is a rare manifestation of cardiac involvement in Behçet's disease, and it may be mistaken for a heart tumor. In this letter we present the case of a patient diagnosed with Behçet's disease who was incidentally found to have a mass in the right atrium suspicious of a cardiac tumor. Nevertheless, cardiac magnetic resonance showed a cardiac thrombus. Immunosuppressive therapy and anticoagulation were effective for thrombus resolution. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. A diagnostic algorithm to optimize data collection and interpretation of Ripple Maps in atrial tachycardias.

    Science.gov (United States)

    Koa-Wing, Michael; Nakagawa, Hiroshi; Luther, Vishal; Jamil-Copley, Shahnaz; Linton, Nick; Sandler, Belinda; Qureshi, Norman; Peters, Nicholas S; Davies, D Wyn; Francis, Darrel P; Jackman, Warren; Kanagaratnam, Prapa

    2015-11-15

    Ripple Mapping (RM) is designed to overcome the limitations of existing isochronal 3D mapping systems by representing the intracardiac electrogram as a dynamic bar on a surface bipolar voltage map that changes in height according to the electrogram voltage-time relationship, relative to a fiduciary point. We tested the hypothesis that standard approaches to atrial tachycardia CARTO™ activation maps were inadequate for RM creation and interpretation. From the results, we aimed to develop an algorithm to optimize RMs for future prospective testing on a clinical RM platform. CARTO-XP™ activation maps from atrial tachycardia ablations were reviewed by two blinded assessors on an off-line RM workstation. Ripple Maps were graded according to a diagnostic confidence scale (Grade I - high confidence with clear pattern of activation through to Grade IV - non-diagnostic). The RM-based diagnoses were corroborated against the clinical diagnoses. 43 RMs from 14 patients were classified as Grade I (5 [11.5%]); Grade II (17 [39.5%]); Grade III (9 [21%]) and Grade IV (12 [28%]). Causes of low gradings/errors included the following: insufficient chamber point density; window-of-interestRipple Maps in atrial tachycardias. This algorithm requires prospective testing on a real-time clinical platform. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. The effectiveness of FDG PET/CT for evaluation of intracardiac mass and pericardiac lesions

    International Nuclear Information System (INIS)

    Hwang, H. S; Yun, M. J.; Lee, J. D

    2004-01-01

    Fluorodeoxyglucose positron emission tomography has been known to be useful in diagnosis and staging of malignancy. FDG PET has high sensitivity and easily detects malignant lesions that are missed and overlooked in anatomic imaging modality. We assessed the impact of FDG PET/CT compared to echocardiogram and enhanced CT scan. Five patients of intra- and pericardiac lesions were included in this study. All patients underwent PET/CT(GE Discovery ST), enhanced CT scan and echocardiogram. Two patients were non-small cell lung cancer, one of RV metastatic mass, the other of pericardial metastasis in RV region. One of melanoma with systemic metastases, had RA malignant masses. One of suspicious lung cancer and intracardiac mass, has proved to benign LA thrombosis. One of lymphoma showed suspicious cardiac mass, but revealed no abnormality in echocardiogram. FDG PET/CT is sensitive and useful method to detect intra- and pericardiac mass in patients with suspected malignancy. All patients except lymphoma were correctly diagnosed using FDG PET/ICT

  12. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  13. Indium-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Michio; Ojima, Kenji; Tsuda, Takashi [Niigata Univ. (Japan). School of Medicine

    1983-09-01

    This study was designed to evaluate the efficacy of scintigraphy by using /sup 111/In-oxine labeled platelets for the detection of either intracardiac or intravascular thrombi. Fourteen cases of thrombi diagnosed or suspected on the basis of either angiography or two-dimensional echography were examined. They included four cases of left ventricular thrombi, three of left atrial thrombi, four of vascular thrombi and three of inflammatory disease. Platelet samples from the patients were labeled by /sup 111/In-oxine according to the method originated by Yui et al. The labeling efficiency was 72.4+-9.8%. The platelets retained good function except for collagen aggregability. Hot areas of high quality in the scintigram were demonstrated in six cases including two with left ventricular thrombi, two with left atrial thrombi and two with vascular thrombi. These areas accorded well with the findings of angiography, echography or surgery. The removed thrombi had a layer of aggregated platelets on the surface. Platelet survival was shortened in a case of prosthetic valve endocarditis without a hot area, and was normal in four out of the five cases including two with a hot area. It is concluded that this method is potentially predictive in detecting thrombi.

  14. Endocarditis associated with intracardiac devices

    International Nuclear Information System (INIS)

    Tourn, J.; Rocha, A.; Jubany, L.; Figueroa, S.; Sasso, D.; Dalto, L.; Ferreiro, A.; Fernandez, P.; Kuster, F.

    2013-01-01

    Full text: Background: Infective endocarditis (I E) associated with intracardiac devices (DIC) (pacemakers and CDAI) is a serious condition associated with high mortality (10-20%). Its incidence is variable according different studies but round 1.9 / 1000 devices year. The Eco and blood cultures are the pillars diagnosis of this disease. Early treatment reduces morbidity and mortality and is the extraction of entire system accompanied prolonged antibiotic therapy. Objective: To analyze the epidemiological, clinical, pathological and disease progression in patients EI carriers with DIC. Method: 3,110 DIC placed in the institution between April 2000 and February 2012 were identified by analysis of medical records EI 26 patients with DIC carriers. For diagnosis they were included EI definite cases according to the criteria Duke. They were classified into early EI (<12 months) or late (> 12 months) from the date of the last implant. Descriptive statistical analysis was performed. Result: The incidence was 8.3 / 1,000 DIC (n = 26). The mean age was 70 ± 10 years, 19 men, 9 diabetic and 16 patients had implemented a Ddd device. In 17 patients underwent more than one replacement device; 10 patients required temporary pacemaker (MPT) prior to placement permanent pacemaker. The average time since the last implant DIC at diagnosis was 710 days. The DIC extraction was early in 8 patients and late in 18. Topography of vegetation: 10 cases over the cable, six tricuspid valve, valve and four over six patient cable and vegetation not found. 15 patients blood cultures were positive; the most frequently found germ was staphylococcus aureus (S A) in nine, being this methicillin-resistant in five of them. The fever accompanied impact elements General was present in 24 cases. The most frequent medical complications were anemia in eight patients and acute renal failure in four patients. Two patients died during hospitalization (7.6%; 95% CI: 0-17.5%). The extraction system was

  15. Science.gov (United States)

    Madeira, João; Parreira, Leonor; Amador, Pedro; Soares, Luís

    2013-10-14

    Riata and Riata ST silicone defibrillation leads are prone to externalization of conductors due to inside-out abrasion in the high-voltage system, causing structural damage which may be accompanied by electrical failure. These situations are easily detected by fluoroscopy or radiology and by inspection of intracardiac electrograms and/or measurement of impedance. However, older pulse generators do not automatically perform all the measurements needed to assess the integrity of the high-voltage electrical system, nor do they have patient notifier alerts in case of dysfunction. The authors describe the case of a patient in whom structural damage was detected on fluoroscopy during pulse generator replacement. They discuss the best strategy in these patients, considering current knowledge of this dysfunction. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  16. Functional pulmonary atresia in newborn with normal intracardiac anatomy: Successful treatment with inhaled nitric oxide and pulmonary vasodilators

    Directory of Open Access Journals (Sweden)

    Gürkan Altun

    2013-01-01

    Full Text Available Functional pulmonary atresia is characterized by a structurally normal pulmonary valve that does not open during right ventricular ejection. It is usually associated with Ebstein′s anomaly, Uhl′s anomaly, neonatal Marfan syndrome and tricuspid valve dysplasia. However, functional pulmonary atresia is rarely reported in newborn with anatomically normal heart. We report a newborn with functional pulmonary atresia who had normal intracardiac anatomy, who responded to treatment with nitric oxide and other vasodilator therapy successfully.

  17. In-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Hanano, Masaharu; Kimura, Michio; Ojima, Kenji [Niigata Univ. (Japan). School of Medicine

    1984-06-01

    /sup 111/In-labeled platelet scintigraphy was carried out in 20 patients suspected of thrombosis, to evaluate its efficacy for the detection of intracardiac and intravascular thrombi. Hemostatic studies including PT, aPTT, fibrinogen, FDP, platelet retention by Hellem II method, platelet aggregation induced by ADP (1 ..mu..M, 10 ..mu..M), collagen (2 ..mu..g/ml) and arachidonate (2 mM), and platelet survival were examined simultaneously. Two of these patients were also studied by fibrinogen scintigraphy labeled with sup(99m)Tc. The platelets obtained from the patients were labeled with /sup 111/In-oxine according to a method originated by Yui et al. In the platelet scintigram, positive findings were demonstrated in 9 cases : 2 left ventricular, 3 left atrial, and 4 vascular thrombi. These were in a good accordance to the findings obtained by at least one from angiography, echography and surgery. Platelet aggregation induced by 1 ..mu..M ADP was elevated in 4 of the 7 patients with positive findings and 3 of the 7 patients with negative findings. Shortened platelet survivals were observed in two of the 10 patients; dissecting aortic aneurysm and infective prosthetic valve endocarditis with hepatosplenomegaly. There was no significant difference in the platelet function and the platelet survival between the patients with positive and negative findings. It was difficult to detect thrombi by the fibrinogen scintigraphy labeled with sup(99m)Tc in the two patients studied. In conclusion, /sup 111/In-labeled platelet scintigraphy seems to be very useful to detect thrombi.

  18. Ventricular rhythm in atrial fibrillation under anaesthetic infusion with propofol

    International Nuclear Information System (INIS)

    Cervigón, R; Moreno, J; Pérez-Villacastín, J; Reilly, R B; Castells, F

    2009-01-01

    Changes in patients' autonomic tone and specific pharmacologic interventions may modify the ventricular response (actual heart rate) during atrial fibrillation (AF). Hypnotic agents such as propofol may modify autonomic balance as they promote a sedative state. It has been shown that propofol slightly slows atrial fibrillatory activity, but the net global effect on the ventricular response remains unknown. We aimed to evaluate in patients in AF the effect of a propofol bolus on the ventricular rate and regularity at ECG. We analysed the possible relation with local atrial fibrillatory activities, as ratios between atrial and ventricular rates (AVRs), analysing atrial activity from intracardiac electrograms at the free wall of the right and left atria and at the interatrial septum. We compared data at the baseline and after complete hypnosis. Propofol was associated with a more homogeneous ventricular response and lower AVR values at the interatrial septum

  19. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    Science.gov (United States)

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  20. Mast Cell Coupling to the Kallikrein–Kinin System Fuels Intracardiac Parasitism and Worsens Heart Pathology in Experimental Chagas Disease

    Directory of Open Access Journals (Sweden)

    Clarissa R. Nascimento

    2017-08-01

    Full Text Available During the course of Chagas disease, infectious forms of Trypanosoma cruzi are occasionally liberated from parasitized heart cells. Studies performed with tissue culture trypomastigotes (TCTs, Dm28c strain demonstrated that these parasites evoke neutrophil/CXCR2-dependent microvascular leakage by activating innate sentinel cells via toll-like receptor 2 (TLR2. Upon plasma extravasation, proteolytically derived kinins and C5a stimulate immunoprotective Th1 responses via cross-talk between bradykinin B2 receptors (B2Rs and C5aR. Awareness that TCTs invade cardiovascular cells in vitro via interdependent activation of B2R and endothelin receptors [endothelin A receptor (ETAR/endothelin B receptor (ETBR] led us to hypothesize that T. cruzi might reciprocally benefit from the formation of infection-associated edema via activation of kallikrein–kinin system (KKS. Using intravital microscopy, here we first examined the functional interplay between mast cells (MCs and the KKS by topically exposing the hamster cheek pouch (HCP tissues to dextran sulfate (DXS, a potent “contact” activator of the KKS. Surprisingly, although DXS was inert for at least 30 min, a subtle MC-driven leakage resulted in factor XII (FXII-dependent activation of the KKS, which then amplified inflammation via generation of bradykinin (BK. Guided by this mechanistic insight, we next exposed TCTs to “leaky” HCP—forged by low dose histamine application—and found that the proinflammatory phenotype of TCTs was boosted by BK generated via the MC/KKS pathway. Measurements of footpad edema in MC-deficient mice linked TCT-evoked inflammation to MC degranulation (upstream and FXII-mediated generation of BK (downstream. We then inoculated TCTs intracardiacally in mice and found a striking decrease of parasite DNA (quantitative polymerase chain reaction; 3 d.p.i. in the heart of MC-deficient mutant mice. Moreover, the intracardiac parasite load was significantly reduced in WT

  1. Intracardiac metastasis of squamous cell carcinoma of the penis

    Directory of Open Access Journals (Sweden)

    Sheila Aparecida Coelho Siqueira

    2013-12-01

    Full Text Available Penile cancer shows variable incidence in different countries with a higher prevalence in developing countries. Squamous cell carcinoma represents the most common histologic type. The seventh decade of life corresponds to the mean age at diagnosis, but it is not an unusual diagnosis among young adults. Most cases present as “in situ” neoplasia or loco regional disease; however, systemic disseminated disease occurs via lymphatic and/or hematogeneous routes. The lymph nodes, liver, and lungs are the most frequently involved sites whereas the heart constitutes an exceptional and atypical site for penile cancer metastases. We report a case of a 79-year-old patient who presented a metastatic squamous cell carcinoma of the penis with intracardiac dissemination. The patient had a past history of cardiomyopathy, which required an artificial cardiac pacemaker implantation. He had been treated 1 year before with a partial penectomy but was admitted for emasculation due to the cancer relapse. During the postoperative period, he experienced sudden respiratory distress and died. The autopsy findings showed metastatic disease into the cardiac right chambers, pulmonary tumoral thrombi, and pulmonary hilar involvement. The authors call attention to the possibility of the presence of pacing leads, cardiomyopathy and the altered low blood flow in the right chambers, as predisposing factors for the tumoral seeding in this case.

  2. Characteristics of complex fractionated atrial electrogram in the electroanatomically remodeled left atrium of patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Park, Jae-Hyung; Kim, Jong-Youn; Park, Sang-Weon

    2010-01-01

    Complex fractionated atrial electrogram (CFAE) guided ablation is effective in some patients with persistent atrial fibrillation (PeAF), but the pattern of CFAE may be different in the remodeled left atrium (LA). In 100 AF patients (83 males, 55.0±10.6 years old) with AF (51 paroxysmal AF (PAF), 49 PeAF) who underwent catheter ablation, CFAE cycle length (CL) and distribution (NavX 3D map) were compared according to the LA volume (3D-CT) and endocardial voltage (during high right atrial pacing 500-ms (Vol PACE ) and AF (Vol AF ; NavX). The mean CFAE-CL was longer (P=0.003) and the % area CFAE was smaller (P=0.006) in patients with LA ≥125 ml than those with PACE AF PACE <1.7 mV than those with ≥1.7 mV (P=0.006). The incidence of septal CFAE was consistently high, regardless of the degree of LA remodeling. In the AF patients with an electroanatomically remodeled LA, the % area of CFAE was smaller and mean CFAE-CL was longer than in those with a less remodeled LA. However, the majority of CFAE are consistently positioned on the septum in the remodeled LA. (author)

  3. A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.

    Science.gov (United States)

    Lee, Warren; Griffin, Weston; Wildes, Douglas; Buckley, Donald; Topka, Terry; Chodakauskas, Thaddeus; Langer, Mark; Calisti, Serge; Bergstøl, Svein; Malacrida, Jean-Pierre; Lanteri, Frédéric; Maffre, Jennifer; McDaniel, Ben; Shivkumar, Kalyanam; Cummings, Jennifer; Callans, David; Silvestry, Frank; Packer, Douglas

    2011-07-01

    We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.

  4. Cardiac resynchronisation therapy in the presence of left-to-right intracardiac shunting: more good than harm?

    Science.gov (United States)

    Kyu, Kyu; Seow, Swee Chong; Wong, Raymond; Kojodjojo, Pipin

    2016-03-17

    An elderly Chinese man with moderately impaired left ventricular function, left bundle branch block and ST-elevation myocardial infarction complicated by ventricular septal rupture had class IV heart failure symptoms refractory to medical and surgical interventions. As a treatment of last resort, a cardiac resynchronisation therapy (CRT) pacemaker was implanted apprehensively, as preoperative concerns were raised whether CRT could exacerbate left-to-right shunting, hence negating the potential benefits of CRT. Introduction of CRT significantly improved the patient's haemodynamic status and symptoms, allowing for successful discharge home. To the best of our knowledge, this is the first report of a patient with severely symptomatic acute heart failure, widened QRS and active left-to-right intracardiac shunting, treated successfully with CRT. 2016 BMJ Publishing Group Ltd.

  5. Intracardiac ultrasound scanner using a micromachine (MEMS) actuator.

    Science.gov (United States)

    Zara, J M; Bobbio, S M; Goodwin-Johansson, S; Smith, S W

    2000-01-01

    Catheter-based intracardiac ultrasound offers the potential for improved guidance of interventional cardiac procedures. The objective of this research is the development of catheter-based mechanical sector scanners incorporating high frequency ultrasound transducers operating at frequencies up to 20 MHz. The authors' current transducer assembly consists of a single 1.75 mm by 1.75 mm, 20 MHz, PZT element mounted on a 2 mm by 2 mm square, 75 mum thick polyimide table that pivots on 3-mum thick gold plated polyimide hinges. The hinges also serve as the electrical connections to the transducer. This table-mounted transducer is tilted using a miniature linear actuator to produce a sector scan. This linear actuator is an integrated force array (IFA), which is an example of a micromachine, i.e., a microelectromechanical system (MEMS). The IFA is a thin (2.2 mum) polyimide membrane, which consists of a network of hundreds of thousands of micron scale deformable capacitors made from pairs of metallized polyimide plates. IFAs contract with an applied voltage of 30-120 V and have been shown to produce strains as large as 20% and forces of up to 8 dynes. The prototype transducer and actuator assembly was fabricated and interfaced with a GagePCI analog to digital conversion board digitizing 12 bit samples at a rate of 100 MSamples/second housed in a personal computer to create a single channel ultrasound scanner. The deflection of the table transducer in a low viscosity insulating fluid (HFE 7100, 3M) is up to +/-10 degrees at scan rates of 10-60 Hz. Software has been developed to produce real-time sector scans on the PC monitor.

  6. Intracardiac foreign body resulting from a transmediastinal gunshot mimics an extracardiac foreign body: An image presentation

    Directory of Open Access Journals (Sweden)

    Hsun-Yi Fu

    2017-10-01

    Full Text Available A transmediastinal gunshot wound (TMGW is one of the most severe traumatic injuries, with a high mortality rate. Prompt diagnosis and emergency surgical intervention with or without cardiopulmonary bypass are usually required to save lives. We report a particular case of TMGW in which the computed tomography imaging findings indicated an extracardiac foreign body. However, intraoperative findings revealed an intracardiac foreign body, and urgent cardiopulmonary bypass was performed to remove the foreign body. We suggest that cardiopulmonary bypass should be on standby during an exploratory sternotomy for TMGW, when the trajectory of the bullet hints at a cardiac-penetrating injury according to imaging studies and the location of the bullet remains unaffected by the patient's postural changes.

  7. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    International Nuclear Information System (INIS)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan

    2016-01-01

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy

  8. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan [PET/CT Center, Gansu Provincial Hospital, Lanzhou (China)

    2016-04-15

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy.

  9. Risk Factors for Intracardiac Thrombosis in the Right Atrium and Superior Vena Cava in Critically Ill Neonates who Required the Installation of a Central Venous Catheter

    Directory of Open Access Journals (Sweden)

    Alfredo Ulloa-Ricardez

    2016-08-01

    Conclusion: This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study.

  10. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    Science.gov (United States)

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  11. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hirtler, Daniel [University Hospital Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology (Heart Center, University of Freiburg), Freiburg (Germany); Garcia, Julio; Barker, Alex J. [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Geiger, Julia [University Childrens' Hospital Zurich, Department of Radiology, Zurich (Switzerland)

    2016-10-15

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  12. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    International Nuclear Information System (INIS)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J.; Geiger, Julia

    2016-01-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  13. Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms

    International Nuclear Information System (INIS)

    Alcaraz, Raúl; Hornero, Fernando; Rieta, José J

    2011-01-01

    The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF

  14. Aspectos técnicos da cateterização do seio coronariano baseada no componente atrial do eletrograma intracavitário e anatomia radiológica durante o procedimento de implante de marcapasso biventricular Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary electrogram and radiological anatomy during the implantation procedure of a biventricular pacemaker

    Directory of Open Access Journals (Sweden)

    Fernando Sérgio Oliva de Souza

    2006-04-01

    Full Text Available OBJETIVO: Apresentar uma proposição técnica baseada na experiência de 130 implantes utilizando técnica simplificada para cateterização do seio coronariano, baseada no componente atrial do eletrograma intracavi-tário e anatomia radiológica. MÉTODOS: De outubro de 2001 a outubro de 2004 foram realiza-dos 130 implantes de marcapasso biventricular, utilizando-se anatomia radiológica e observação de eletrograma intracavitário, com prioridade ao componente atrial. RESULTADOS: O implante do sistema, utilizando-se a estimulação do ventrículo esquerdo via seio coronariano, não foi possível em 8 pacientes. Em 12 pacientes foram observadas dificuldades na canulação do óstio coronário e em 15 pacientes observaram-se dificuldades de progressão do eletrodo através do seio coronariano. O tempo médio de utilização de radioscopia foi de 18,69 min. CONCLUSÃO: A técnica de implante, utilizando a morfologia do componente atrial do eletrograma intracavitário e anatomia radiológica, demonstrou ser pouco trabalhosa, segura e eficaz para canulação do óstio do seio coronariano, necessitando de reduzido tempo de radioscopia.OBJECTIVE: To present a technical proposal based on the experience of 130 implantations using a simplified technique for coronary sinus catheterization, based on the atrial component of the intracavitary electrogram and radiological anatomy. METHODS: From October, 2001 to October, 2004, 130 biventricular pacemaker implantations were performed, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 8 patients. Difficulties on the cannulation of the coronary ostium were felt in 12 patients and difficulties of lead advancement through the coronary sinus were felt in 15 patients. The mean time of radioscopy utilization was 18.69 min. CONCLUSION: The

  15. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  16. Symmetrical compression distance for arrhythmia discrimination in cloud-based big-data services.

    Science.gov (United States)

    Lillo-Castellano, J M; Mora-Jiménez, I; Santiago-Mozos, R; Chavarría-Asso, F; Cano-González, A; García-Alberola, A; Rojo-Álvarez, J L

    2015-07-01

    The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.

  17. Low-Grade Endometrial Stromal Sarcoma with Intravenous and Intracardiac Extension: A Multidisciplinary Approach

    Directory of Open Access Journals (Sweden)

    Wataru Kudaka

    2016-01-01

    Full Text Available Background. A rare case of low-grade endometrial stromal sarcoma (LG-ESS extending to inferior vena cava (IVC and cardiac chambers. Case Report. A 40-year-old woman had IVC tumor, which was incidentally detected by abdominal ultrasonography during a routine medical checkup. CT scan revealed a tumor in IVC, right iliac and ovarian veins, which was derived from the uterus and extended into the right atrium and ventricle. The operation was performed, the heart and IVC were exposed, and cardiopulmonary bypass was initiated. A right atriotomy was performed, and the intracardiac mass was removed. Then the tumor in IVC and the right internal iliac vein were removed after longitudinal venotomies in the suprarenal and infrarenal vena cava, the right common iliac vein. Next the pelvis was explored. Tumors were found originating from the posterior wall of the uterus and continuing into both the right uterine and ovarian vein. The patient underwent total hysterectomy with bilateral salpingooophorectomy. Complete tumor resection was achieved. Histopathological analysis confirmed a diagnosis of LG-ESS. She showed no evidence of disease for 2 years and 3 months. Conclusions. Our case highlights the importance of a multidisciplinary approach in treating this rare cardiovascular pathological condition through preoperative assessment to final operation.

  18. Successful Management of Tubal Ectopic Pregnancy with Transvaginal Sonography Guided Intracardiac KCL Injection and Systemic Methotrexate - A Case Report

    Directory of Open Access Journals (Sweden)

    Sumesh Choudhary

    2014-01-01

    Full Text Available Background: Methotrexate (Mtx is an accepted modality for conservative treatment of ectopic pregnancy. However, there is no consensus regarding its use in live ectopic pregnancy and high serum beta-human chorionic gonadotrophin (β-hCG titres. Concurrent use of intra-sac hypertonic KCl, to produce cardiac asystole with systemic Mtx potentially improve outcome in live ectopic gestations with very high serum β-hCG titres. Here a successful management of live ectopic pregnancy in a 25-year-old nulliparous woman, with very high β-hCG titres (29502.04mIU/mL, using ultrasound-guided intra-cardiac potassium chloride (KCl injection and systemic Mtx is reported. No treatment related complications were encountered. However, individualized treatment with a stringent follow-up regime is mandatory in such cases.

  19. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2015-01-01

    Full Text Available Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforation, arrhythmias, sepsis, and pulmonary embolism. A 12-year-old female received chemotherapy for acute lymphocytic leukemia through a central venous port implanted into her right subclavian area. The patient completed chemotherapy without complications 6 months ago. Venous port was accidentally fractured during its removal. Chest radiographs of the patient revealed intracardiac catheter fragment extending from the right subclavian to the right atrium (RA and looping in the RA. The procedure was performed under ketamine and midazolam anesthesia and fluoroscopic guidance using a percutaneous femoral vein approach. A snare with triple loops (10 mm in diameter was used to successfully retrieve the catheter fragments without any complication. Percutaneous transcatheter retrieval of catheter fragments is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters and can be chosen before resorting to surgery, which has potential risks related to thoracotomy, cardiopulmonary bypass, and general anesthesia.

  20. Echogenic intracardiac focus on second trimester ultrasound: prevalence and significance in a Middle Eastern population.

    Science.gov (United States)

    Mirza, Fadi G; Ghulmiyyah, Labib; Tamim, Hani; Bou Hamdan, Farah; Breidy, Juliana; Geagea, Sandra; Usta, Ihab; Adra, Abdallah; Nassar, Anwar H

    2016-01-01

    The association between echogenic intracardiac focus (EIF) and trisomy 21 is well established, with a recognized ethnic variation. Our study aimed to determine the prevalence of EIF in a Middle Eastern population and to examine its association with trisomy 21 and other adverse pregnancy outcomes. Retrospective case-control study of second-trimester obstetric sonograms (16-28 weeks) performed at a tertiary care center over a 5-year period. Cases with EIF were retrieved, and a matched control group with no EIF was identified. The incidence of trisomy 21 and other adverse pregnancy outcomes was compared. A total of 9270 obstetric sonograms were examined, with an EIF prevalence of 2.5% (95% CI: 2.2-2.8%). Of patients with available outcome data, EIF was not associated with trisomy 21 (0/163 versus 1/163; p value = 1.00). Additionally, EIF was not associated with trisomy 18, trisomy 13, small for gestational age, preterm birth, fetal demise, cesarean delivery, operative vaginal delivery, or admission to the neonatal intensive care unit. In a contemporary Middle Eastern population, EIF is a rare occurrence. As an isolated finding, it is not associated with aneuploidy or other adverse pregnancy outcomes. EIF appears to be incidental with no impact on clinical practice.

  1. Evaluation of aspirin therapy on intracardiac thrombi using indium-111-oxine platelet scintigraphy, two-dimentional echocardiography and left ventriculography

    International Nuclear Information System (INIS)

    Shibuya, Masanori; Irino, Tadayoshi; Yoshioka, Toshiharu; Sugimoto, Tsuyoshi; Tsuji, Kazuo; Naka, Masashi; Arai, Hidekazu.

    1984-01-01

    Left ventriculography (LVG), two-dimensional echocardiography (2-DE) and indium-111-oxine platelet scintigraphy were performed in five patients with intracardiac thrombi. Thrombi were visible in 7 sites (5 in the ventricle and 2 in the atrium) by platelet scintigraphy, in 4 sites (3 in the ventricle and 1 in the atrium) by 2-DE, and in 4 sites (4 in the ventricle) by LVG. When aspirin was administered to the patients, platelet scintigraphy had become negative for thrombi in 5 sites and false-negative for them in 2 sites. However, thrombi were detected in 6 sites after the withdrawal of aspirin. On the other hand, thrombi were detected in 4 sites by 2-DE, irrespective of the administration of aspirin. Indium-111-oxine platelet scintigraphy has proved to not only have higher sensitivity for detecting thrombi but also to be capable of observing the coagulation status of platelets on the thrombi. It is therefore considered very helpful in assessing anticoagulation therapy. (Namekawa, K)

  2. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    Science.gov (United States)

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  3. Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.

    Science.gov (United States)

    Leite, Luiz R; Santos, Simone N; Maia, Henrique; Henz, Benhur D; Giuseppin, Fábio; Oliverira, Anderson; Zanatta, André R; Peres, Ayrton K; Novakoski, Clarissa; Barreto, Jose R; Vassalo, Fabrício; d'Avila, Andre; Singh, Sheldon M

    2011-04-01

    Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. Forty-five consecutive patients undergoing an atrial fibrillation ablation procedure followed by esophageal endoscopy were included in this prospective observational pilot study. LET monitoring was performed with a 7F deflectable ablation catheter that was positioned as close as possible to the site of left atrial ablation using the deflectable component of the catheter guided by visualization of its position on intracardiac echocardiography. Ablation in the posterior left atrial was limited to 25 W and terminated when the LET increased 2°C from baseline. Endoscopy was performed 1 to 2 days after the procedure. All patients had at least 1 LET elevation >2°C necessitating cessation of ablation. Deflection of the LET probe was needed to accurately measure LET in 5% of patients when ablating near the left pulmonary veins, whereas deflection of the LET probe was necessary in 88% of patients when ablating near the right pulmonary veins. The average maximum increase in LET was 2.5±1.5°C. No patients had esophageal thermal injury on follow-up endoscopy. A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.

  4. Left ventricular approach for recording His bundle potential in man.

    Science.gov (United States)

    Lee, Y S; Lien, W P

    1975-06-01

    The electrical potentials of the His bundle (HB) were recorded from the left ventricular endocardial surface in 28 patients ranging from 16 to 63 years of age. In 14 of the patients the left bundle branch (LB) potentials were also obtained. Placement of a bipolar electrode catheter tip toward the interventricular septum, right at and also 1 to 2 cm below the aortic valve, resulted in stable recordings of both potentials in successive cardiac cycles even at performing atrial or HB pacing from the right heart. The following intervals were measured in milliseconds (msec): P-A, A-H, H, H-V, LB, and LB-V. The average values in 12 patients (average age 26 plus or minus 7 years and average heart rate 90 plus or minus 16 beats per minute) with normal A-V conduction were as follows: P-A 28 plus or minus 7, A-H 76 plus or minus 16, H 19 plus or minus 3 and H-V 45 plus or minus 6 msec. The average values for LB and LB-V in 10 of these 12 patients were 15 plus or minus 3 and 25 plus or minus 3 msec respectively. Validation of the His bundle electrogram (HBE) from the left ventricular endocardial surface was based on simultaneous recordings of the intracardiac electrograms from both left and right sides of the heart in 18 patients. The individual average values for the intervals obtained from both sides of the heart in these patients were statistically not different, except that the H potential was slightly longer in duration fr m the left heart (P equals 0.05). Among these, 16 showed simultaneous onset of the H potentials, and the LB-V and RB-V conduction times from comparable points were almost the same. Indications for the left sided electro-physiologic studies include the following situations: (a) inability to record H from the right of the heart; (b) giant right atrium; and (c) possibly during atrial fibrillation.

  5. Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps With Manifold Harmonics.

    Science.gov (United States)

    Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L

    2018-04-01

    Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.

  6. Comparing Methods for Cardiac Output

    DEFF Research Database (Denmark)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F

    2018-01-01

    of the left ventricular outflow tract. METHODS: The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed...... tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation......, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias...

  7. Use of Intracardiac Echocardiography in Interventional Cardiology: Working With the Anatomy Rather Than Fighting It.

    Science.gov (United States)

    Enriquez, Andres; Saenz, Luis C; Rosso, Raphael; Silvestry, Frank E; Callans, David; Marchlinski, Francis E; Garcia, Fermin

    2018-05-22

    The indications for catheter-based structural and electrophysiological procedures have recently expanded to more complex scenarios, in which an accurate definition of the variable individual cardiac anatomy is key to obtain optimal results. Intracardiac echocardiography (ICE) is a unique imaging modality able to provide high-resolution real-time visualization of cardiac structures, continuous monitoring of catheter location within the heart, and early recognition of procedural complications, such as pericardial effusion or thrombus formation. Additional benefits are excellent patient tolerance, reduction of fluoroscopy time, and lack of need for general anesthesia or a second operator. For these reasons, ICE has largely replaced transesophageal echocardiography as ideal imaging modality for guiding certain procedures, such as atrial septal defect closure and catheter ablation of cardiac arrhythmias, and has an emerging role in others, including mitral valvuloplasty, transcatheter aortic valve replacement, and left atrial appendage closure. In electrophysiology procedures, ICE allows integration of real-time images with electroanatomic maps; it has a role in assessment of arrhythmogenic substrate, and it is particularly useful for mapping structures that are not visualized by fluoroscopy, such as the interatrial or interventricular septum, papillary muscles, and intracavitary muscular ridges. Most recently, a three-dimensional (3D) volumetric ICE system has also been developed, with potential for greater anatomic information and a promising role in structural interventions. In this state-of-the-art review, we provide guidance on how to conduct a comprehensive ICE survey and summarize the main applications of ICE in a variety of structural and electrophysiology procedures. © 2018 American Heart Association, Inc.

  8. Dynamic Approximate Entropy Electroanatomic Maps Detect Rotors in a Simulated Atrial Fibrillation Model

    Science.gov (United States)

    Ugarte, Juan P.; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John

    2014-01-01

    There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping. PMID:25489858

  9. Dynamic approximate entropy electroanatomic maps detect rotors in a simulated atrial fibrillation model.

    Science.gov (United States)

    Ugarte, Juan P; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John

    2014-01-01

    There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping.

  10. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    Science.gov (United States)

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and

  11. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    Science.gov (United States)

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential

  12. Investigation of atrial vulnerability by analysis of the sinus node EG from atrial fibrillation models using a phase synchronization method.

    Science.gov (United States)

    Chen, Ying; Wu, Zhong; Yang, Cuiwei; Shao, Jun; Wong, Kelvin Kian Loong; Abbott, Derek

    2012-09-01

    Atrial fibrillation (AF) can result in life-threatening arrhythmia, and a clinically convenient means for detecting vulnerability remains elusive. We investigated atrial vulnerability by analyzing the sinus electrogram (EG) from AF animal models using a phase synchronization method. Using acetylcholine (ACh)-induced acute canine AF models (n= 4), a total of 128 electrical leads were attached to the surface of the anterior and posterior atria, and the pulmonary veins to form an electrocardiological mapping system. ACh was injected at varying concentrations with ladder-type adjustments. Sinus EGs and induced AF EGs that pertain to specific ACh concentrations were recorded.We hypothesize that the atrial vulnerability may be correlated with the Shannon entropy (SE) of the phase difference matrix that is extracted from the sinus EG. Our research suggests that the combination of SE with the synchronization method enables the sinus node EG to be analyzed and used to estimate atrial vulnerability.

  13. Unipolar Endocardial Voltage Mapping in the Right Ventricle: Optimal Cutoff Values Correcting for Computed Tomography-Derived Epicardial Fat Thickness and Their Clinical Value for Substrate Delineation.

    Science.gov (United States)

    Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja

    2017-08-01

    Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance 1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV the remaining could be identified by corresponding low endocardial UV right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.

  14. Electrophysiologic and anatomical characteristics of the right atrial posterior wall in patients with and without atrial flutter. Analysis by intracardiac echocardiography

    International Nuclear Information System (INIS)

    Okumura, Yasuo; Watanabe, Ichiro; Ashino, Sonoko

    2007-01-01

    The posterior right atrial transverse conduction capability during typical atrial flutter (AFL) is well known, but its relationship to the anatomical characteristics remains controversial. Thirty-four AFL and 16 controls underwent intracardiac echocardiography after placement of a 20-polar catheter at the posterior block site during AFL or pacing. In 31 patients, the effective refractory period (ERP) at the block site was determined as the longest coupling interval that resulted in double potentials during extrastimuli from the mid-septal (SW) and free (FW) walls. The block site was located 3.0-29.0 mm posterior to the crista terminalis (CT) in each AFL and control patient. The CT area indexed to the body surface area was larger in AFL patients than in control patients (16.4±6.5 mm 2 /m 2 vs 11.3±6.4 mm 2 /m 2 , p=0.01), and was positively correlated to age (r=0.34, p=0.02). The ERP was longer in the AFL patients than in controls (SW: median value 600 [270-725] ms vs 220 [200-253] ms; FW: 280 [230-675] ms vs 215 [188-260] ms, p<0.05 for each). A functional block line was located on the septal side of the CT in all patients. A limited conduction capability and age-related CT enlargement might have important implications for the pathogenesis in AFL. (author)

  15. Waveform Integrity in Atrial Fibrillation: The Forgotten Issue of Cardiac Electrophysiology.

    Science.gov (United States)

    Martínez-Iniesta, Miguel; Ródenas, Juan; Alcaraz, Raúl; Rieta, José J

    2017-08-01

    Atrial fibrillation (AF) is the most common arrhythmia in clinical practice with an increasing prevalence of about 15% in the elderly. Despite other alternatives, catheter ablation is currently considered as the first-line therapy for the treatment of AF. This strategy relies on cardiac electrophysiology systems, which use intracardiac electrograms (EGM) as the basis to determine the cardiac structures contributing to sustain the arrhythmia. However, the noise-free acquisition of these recordings is impossible and they are often contaminated by different perturbations. Although suppression of nuisance signals without affecting the original EGM pattern is essential for any other later analysis, not much attention has been paid to this issue, being frequently considered as trivial. The present work introduces the first thorough study on the significant fallout that regular filtering, aimed at reducing acquisition noise, provokes on EGM pattern morphology. This approach has been compared with more refined denoising strategies. Performance has been assessed both in time and frequency by well established parameters for EGM characterization. The study comprised synthesized and real EGMs with unipolar and bipolar recordings. Results reported that regular filtering altered substantially atrial waveform morphology and was unable to remove moderate amounts of noise, thus turning time and spectral characterization of the EGM notably inaccurate. Methods based on Wavelet transform provided the highest ability to preserve EGM morphology with improvements between 20 and beyond 40%, to minimize dominant atrial frequency estimation error with up to 25% reduction, as well as to reduce huge levels of noise with up to 10 dB better reduction. Consequently, these algorithms are recommended as a replacement of regular filtering to avoid significant alterations in the EGMs. This could lead to more accurate and truthful analyses of atrial activity dynamics aimed at understanding and

  16. 4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography.

    Science.gov (United States)

    Wildes, Douglas; Lee, Warren; Haider, Bruno; Cogan, Scott; Sundaresan, Krishnakumar; Mills, David M; Yetter, Christopher; Hart, Patrick H; Haun, Christopher R; Concepcion, Mikael; Kirkhorn, Johan; Bitoun, Marc

    2016-12-01

    We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

  17. Reply to the commentary by Hillman et al. on: "Vascular distensibilities have minor effects on intracardiac shunt patterns in reptiles" by Filogonio et al. (2017).

    Science.gov (United States)

    Filogonio, Renato; Costa Leite, Cléo Alcantara; Wang, Tobias

    2017-06-01

    Our meta-analysis (Filogonio et al., 2017) on central vascular blood flows in a snake (Crotalus durissus) and a turtle (Trachemys scripta) was motivated by Hillman et al.'s (2014) analysis on amphibians to investigate whether cardiac shunt patterns depend on cardiac output and vascular distensibilities. In contrast to Hillman et al. (2014), we did not uncover a general trend that supports the notion that cardiac shunts in reptiles are dictated by vascular distensibilities. In addition to our response to the criticism raised by Hillman et al. (2017), we suggest that future experiments should consider (i) both compliance and distensibility of the major arteries; (ii) differences in volume of the systemic and pulmonary circuits to account for the accommodation of stroke volume; and (iii) an evaluation of the pulsatile pressures in both the ventricle and the major arteries to consider the timing of the ventricular ejection provided by opening of the ventricular valves. We hope these suggestions may help future clarification of the relative importance of passive arterial mechanical properties compared to autonomic regulation in determining intracardiac shunts in both amphibians and reptiles. Copyright © 2017 Elsevier GmbH. All rights reserved.

  18. Ventricular tachycardia in ischemic heart disease substrates

    Directory of Open Access Journals (Sweden)

    Olujimi A. Ajijola

    2014-01-01

    This review will discuss the central role of the ischemic heart disease substrate in the development MMVT. Electrophysiologic characterization of the post-infarct myocardium using bipolar electrogram amplitudes to delineate scar border zones will be reviewed. Functional electrogram determinants of reentrant circuits such as isolated late potentials will be discussed. Strategies for catheter ablation of reentrant ventricular tachycardia, including structural and functional targets will also be examined, as will the role of the epicardial mapping and ablation in the management of recurrent MMVT.

  19. A new LMS algorithm for analysis of atrial fibrillation signals

    OpenAIRE

    Ciaccio Edward J; Biviano Angelo B; Whang William; Garan Hasan

    2012-01-01

    Abstract Background A biomedical signal can be defined by its extrinsic features (x-axis and y-axis shift and scale) and intrinsic features (shape after normalization of extrinsic features). In this study, an LMS algorithm utilizing the method of differential steepest descent is developed, and is tested by normalization of extrinsic features in complex fractionated atrial electrograms (CFAE). Method Equations for normalization of x-axis and y-axis shift and scale are first derived. The algori...

  20. A system and method for online high-resolution mapping of gastric slow-wave activity.

    Science.gov (United States)

    Bull, Simon H; O'Grady, Gregory; Du, Peng; Cheng, Leo K

    2014-11-01

    High-resolution (HR) mapping employs multielectrode arrays to achieve spatially detailed analyses of propagating bioelectrical events. A major current limitation is that spatial analyses must currently be performed "off-line" (after experiments), compromising timely recording feedback and restricting experimental interventions. These problems motivated development of a system and method for "online" HR mapping. HR gastric recordings were acquired and streamed to a novel software client. Algorithms were devised to filter data, identify slow-wave events, eliminate corrupt channels, and cluster activation events. A graphical user interface animated data and plotted electrograms and maps. Results were compared against off-line methods. The online system analyzed 256-channel serosal recordings with no unexpected system terminations with a mean delay 18 s. Activation time marking sensitivity was 0.92; positive predictive value was 0.93. Abnormal slow-wave patterns including conduction blocks, ectopic pacemaking, and colliding wave fronts were reliably identified. Compared to traditional analysis methods, online mapping had comparable results with equivalent coverage of 90% of electrodes, average RMS errors of less than 1 s, and CC of activation maps of 0.99. Accurate slow-wave mapping was achieved in near real-time, enabling monitoring of recording quality and experimental interventions targeted to dysrhythmic onset. This work also advances the translation of HR mapping toward real-time clinical application.

  1. HEREDITARY INTRAVENTRICULAR CONDUCTION DISORDERS IN THE FAMILY FROM KRASNOYARSK

    Directory of Open Access Journals (Sweden)

    A. A. Chernova

    2011-01-01

    Full Text Available Pedigree of the family from Krasnoyarsk city with hereditary disorders of intracardiac conduction was studied. The diagnosis of each family member was verified by electrocardiography (ECG, echocardiography , bicycle ergometry , ECG Holter monitoring. The family 10-year follow-up showed familial aggregation of intracardiac conduction disorders in grandson, niece, son of the proband niece, ie, in the III-degree relatives. Family history of III-degree relatives with intracardiac conduction disorders and discordant pathology is identified.

  2. Spiral waves characterization: Implications for an automated cardiodynamic tissue characterization.

    Science.gov (United States)

    Alagoz, Celal; Cohen, Andrew R; Frisch, Daniel R; Tunç, Birkan; Phatharodom, Saran; Guez, Allon

    2018-07-01

    Spiral waves are phenomena observed in cardiac tissue especially during fibrillatory activities. Spiral waves are revealed through in-vivo and in-vitro studies using high density mapping that requires special experimental setup. Also, in-silico spiral wave analysis and classification is performed using membrane potentials from entire tissue. In this study, we report a characterization approach that identifies spiral wave behaviors using intracardiac electrogram (EGM) readings obtained with commonly used multipolar diagnostic catheters that perform localized but high-resolution readings. Specifically, the algorithm is designed to distinguish between stationary, meandering, and break-up rotors. The clustering and classification algorithms are tested on simulated data produced using a phenomenological 2D model of cardiac propagation. For EGM measurements, unipolar-bipolar EGM readings from various locations on tissue using two catheter types are modeled. The distance measure between spiral behaviors are assessed using normalized compression distance (NCD), an information theoretical distance. NCD is a universal metric in the sense it is solely based on compressibility of dataset and not requiring feature extraction. We also introduce normalized FFT distance (NFFTD) where compressibility is replaced with a FFT parameter. Overall, outstanding clustering performance was achieved across varying EGM reading configurations. We found that effectiveness in distinguishing was superior in case of NCD than NFFTD. We demonstrated that distinct spiral activity identification on a behaviorally heterogeneous tissue is also possible. This report demonstrates a theoretical validation of clustering and classification approaches that provide an automated mapping from EGM signals to assessment of spiral wave behaviors and hence offers a potential mapping and analysis framework for cardiac tissue wavefront propagation patterns. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Radionuclide determination of right and left ventricular stroke volumes

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wei Feng; Roubin, G S; Choong, C Y.P.; Harris, P J; Flether, P J; Kelly, D T; Uren, R F; Hutton, B F

    1985-03-01

    The relationship between radionuclide and thermodilution measurement of stroke volumes (SV) was investigated in 30 patients without valvular regurgitation or intracardiac shunt (group A) at rest and during exercise. Both attenuated radionuclide right ventricular (RV) and left ventricular (LV) SV measurements correlated well with the SV determined by the thermodilution method (r = 0.87 and r = 0.93, all P < 0.001). The reliability of the radionuclide method to estimate SV was evaluated prospectively in two additional groups of patients. In 11 patients without valvular regurgitation or intracardiac shunt (group B) the radionuclide RVSV and LVSV closely approximated to thermodilution SV at rest and during exercise. In 15 patients with aortic regurgitation (group C) the radionuclide stroke volume ratio correlated well with the angiographic regurgitant fraction. Thus, both RVSV and LVSV and the severity of aortic regurgitation can be reliably measured with gated radionuclide ventriculography.

  4. Current strategies for non-pharmacological therapy of long-standing persistent atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Teiichi Yamane, MD, PhD

    2012-06-01

    Full Text Available Non-pharmacological rhythm control of atrial fibrillation (AF is becoming increasingly important in our aging society. Advancement of catheter ablation techniques in the last decade has provided a cure for AF patients, with a nearly established efficiency for paroxysmal cases. However, since ablation of persistent/chronic AF cases is still challenging, early treatment of paroxysmal AF before transformation to the persistent/chronic form is mandatory. Although there is a consensus that pulmonary vein isolation is the first-line approach for ablation of long-standing persistent AF, similar to that for paroxysmal AF, there are still wide variations in the adjunctive approach to modify the atrial substrate of persistent AF (anatomical linear ablation, electrogram-based complex fractionated atrial electrogram ablation, ganglionated plexus ablation, etc.. Since data comparing the effectiveness of these adjunctive approaches are still lacking, large-scale controlled trials evaluating the effect of catheter ablation in diverse patient populations on a long-term basis are needed to establish the appropriate approach for long-standing persistent AF. Furthermore, the development of de novo ablation methods (new energies, new targets, etc. is expected to improve ablation outcome in patients with long-standing persistent AF.

  5. Zero-fluoroscopy cryothermal ablation of atrioventricular nodal re-entry tachycardia guided by endovascular and endocardial catheter visualization using intracardiac echocardiography (Ice&ICE Trial).

    Science.gov (United States)

    Luani, Blerim; Zrenner, Bernhard; Basho, Maksim; Genz, Conrad; Rauwolf, Thomas; Tanev, Ivan; Schmeisser, Alexander; Braun-Dullaeus, Rüdiger C

    2018-01-01

    Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions. © 2017 Wiley Periodicals, Inc.

  6. Cardiac dimensional analysis by use of biplane cineradiography: description and validation of method.

    Science.gov (United States)

    Lipscomb, K

    1980-01-01

    Biplane cineradiography is a potentially powerful tool for precise measurement of intracardiac dimensions. The most systematic approach to these measurements is the creation of a three-dimensional coordinate system within the x-ray field. Using this system, interpoint distances, such as between radiopaque clips or coronary artery bifurcations, can be calculated by use of the Pythagoras theorem. Alternatively, calibration factors can be calculated in order to determine the absolute dimensions of a structure, such as a ventricle or coronary artery. However, cineradiography has two problems that have precluded widespread use of the system. These problems are pincushion distortion and variable image magnification. In this paper, methodology to quantitate and compensate for these variables is presented. The method uses radiopaque beads permanently mounted in the x-ray field. The position of the bead images on the x-ray film determine the compensation factors. Using this system, measurements are made with a standard deviation of approximately 1% of the true value.

  7. Comparison of tissue processing methods for microvascular visualization in axolotls.

    Science.gov (United States)

    Montoro, Rodrigo; Dickie, Renee

    2017-01-01

    The vascular system, the pipeline for oxygen and nutrient delivery to tissues, is essential for vertebrate development, growth, injury repair, and regeneration. With their capacity to regenerate entire appendages throughout their lifespan, axolotls are an unparalleled model for vertebrate regeneration, but they lack many of the molecular tools that facilitate vascular imaging in other animal models. The determination of vascular metrics requires high quality image data for the discrimination of vessels from background tissue. Quantification of the vasculature using perfused, cleared specimens is well-established in mammalian systems, but has not been widely employed in amphibians. The objective of this study was to optimize tissue preparation methods for the visualization of the microvascular network in axolotls, providing a basis for the quantification of regenerative angiogenesis. To accomplish this aim, we performed intracardiac perfusion of pigment-based contrast agents and evaluated aqueous and non-aqueous clearing techniques. The methods were verified by comparing the quality of the vascular images and the observable vascular density across treatment groups. Simple and inexpensive, these tissue processing techniques will be of use in studies assessing vascular growth and remodeling within the context of regeneration. Advantages of this method include: •Higher contrast of the vasculature within the 3D context of the surrounding tissue •Enhanced detection of microvasculature facilitating vascular quantification •Compatibility with other labeling techniques.

  8. Intra-cardiac pacemaker infection: Surgical management and outcome

    Directory of Open Access Journals (Sweden)

    Sameh Elameen

    2016-05-01

    Conclusion: Explantation of the complete pacemaker system has proved a reliable method to eradicate infection. Complications were rare, except in patients who present lately in a critically ill condition and septic shock.

  9. Intracardiac Metastatic Rhabdomyosarcoma

    Directory of Open Access Journals (Sweden)

    Tae Ho Kim

    2015-12-01

    Full Text Available A 70-year-old man who visited Samsung Medical Center reported experiencing palpitation for 2 weeks. He had undergone excision of a mass in the right buttock due to rhabdomyosarcoma 7 years prior to this visit. Transesophageal echocardiography showed a pedunculated mass in the left ventricle, which was thought to be a vegetation of infective endocarditis, metastasis of the primary tumor, or thrombus. He underwent removal of the cardiac tumor, and the pathologic report was metastatic rhabdomyosarcoma. Thus, here, we report a rare case of metastatic rhabdomyosarcoma in the left ventricle.

  10. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    Science.gov (United States)

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  11. Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Active Curves

    International Nuclear Information System (INIS)

    Kim, Ok Hwa; Bahk, Yong Whee; Kim, Chi Kyung

    1987-01-01

    The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atriurn, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intracardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/ QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs

  12. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    Science.gov (United States)

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T wave oversensing, leading to ventricular oversensing with resultant detection in the ventricular fibrillation rate zone. This was followed by shock therapy, even though the ventricular tachycardia rate was below the programmed detection rate of the ICD. The subsequent emergency treatment of the hyperkalemia normalized the electrogram, corrected the ventricular oversensing and arrhythmia, and restored rate-adaptive single-chamber ventricular pacing. PMID:18340383

  13. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  14. Effects of unilateral stellate ganglion stimulation and ablation on electrophysiologic changes induced by acute myocardial ischemia in dogs

    NARCIS (Netherlands)

    Janse, M. J.; Schwartz, P. J.; Wilms-Schopman, F.; Peters, R. J.; Durrer, D.

    1985-01-01

    We recorded direct-current extracellular electrograms simultaneously from 60 left ventricular epicardial sites in 38 alpha-chloralose-anesthetized dogs during repeated, 5 min coronary arterial occlusions. In each dog recordings made during control occlusions were compared with those made in

  15. Electrocardiogram: his bundle potentials can be recorded noninvasively beat by beat on surface electrocardiogram.

    Science.gov (United States)

    Wang, Gaopin; Liu, Renguang; Chang, Qinghua; Xu, Zhaolong; Zhang, Yingjie; Pan, Dianzhu

    2017-03-15

    The micro waveform of His bundle potential can't be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram. We randomized 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia (exclude overt Wolff-Parkinson-White syndrome) to receive "conventional electrocardiogram" and "new electrocardiogram" before the procedure. His bundle electrogram was collected during the procedure. Comparative analysis of PA s (PA interval recorded on surface electrocardiogram), AH s (AH interval recorded on surface electrocardiogram) and HV s (HV interval recorded on surface electrocardiogram) interval recorded on surface "new electrocardiogram" and PA, AH, HV interval recorded on His bundle electrogram was investigated. There was no difference (P > 0.05) between groups in HV s interval (49.63 ± 6.19 ms) and HV interval (49.35 ± 6.49 ms). Results of correlational analysis found that HV S interval was significantly positively associated with HV interval (r = 0.929; P electrocardiogram. Noninvasive His bundle potential tracing might represent a new method for locating the site of atrioventricular block and identifying the origin of a wide QRS complex.

  16. Intracardiac electrophysiology study (EPS)

    Science.gov (United States)

    ... rhythm Determine whether you are at risk for future heart events, especially sudden cardiac death See if ... patient with suspected arrhythmia. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: ...

  17. Positive predictive value of device-detected atrial high-rate episodes at different rates and durations

    DEFF Research Database (Denmark)

    Kaufman, Elizabeth S; Israel, Carsten W; Nair, Girish M

    2012-01-01

    BACKGROUND: Pacemakers can automatically identify and catalog atrial high-rate episodes (AHREs). While most AHREs represent true atrial tachyarrhythmia/atrial fibrillation (AT/AF), a review of stored electrograms suggests that a substantial proportion do not. As AHREs may lead to the initiation o...

  18. The identification of conduction gaps after pulmonary vein isolation using a new electroanatomic mapping system.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2017-11-01

    The reconnection of left atrial-pulmonary vein (LA-PV) conduction after the initial procedure of pulmonary vein (PV) isolation is not rare, and is one of the main cause of atrial fibrillation (AF) recurrence after PV isolation. We investigated feasibility of a new ultrahigh-resolution mapping system using a 64-pole small basket catheter for the identification of LA-PV conduction gaps. This prospective study included 31 consecutive patients (20 with persistent AF) undergoing a second ablation after a PV isolation procedure with LA-PV reconnected conduction at any of the 4 PVs. An LA-PV map was created using the mapping system, and ablation was performed at the estimated gap location. The propagation map identified 54 gaps from 39 ipsilateral PV pairs, requiring manual electrogram reannotation for 23 gaps (43%). Gaps at the anterior and carinal regions of left and right ipsilateral PVs required manual electrogram reannotation more frequently than the other regions. The voltage map could identify the gap only in 19 instances (35%). Electrophysiological properties of the gaps (multiple gaps in the same ipsilateral PVs, conduction time, velocity, width, and length) did not differ between those needing and not needing manual electrogram reannotation. During the gap ablation, either the activation sequence alteration or elimination of PV potentials was observed using a circular catheter placed in the PV, suggesting that all the identified gaps were correct. This new electroanatomic mapping system visualized all the LA-PV gaps in patients undergoing a second AF ablation. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Insights into new-onset atrial fibrillation following open heart surgery and implications for type II atrial flutter.

    Science.gov (United States)

    Sadrpour, Shervin A; Srinivasan, Deepa; Bhimani, Ashish A; Lee, Seungyup; Ryu, Kyungmoo; Cakulev, Ivan; Khrestian, Celeen M; Markowitz, Alan H; Waldo, Albert L; Sahadevan, Jayakumar

    2015-12-01

    Postoperative atrial fibrillation (POAF), new-onset AF after open heart surgery (OHS), is thought to be related to pericarditis. Based on AF studies in the canine sterile pericarditis model, we hypothesized that POAF in patients after OHS may be associated with a rapid, regular rhythm in the left atrium (LA), suggestive of an LA driver maintaining AF. The aim of this study was to test the hypothesis that in patients with POAF, atrial electrograms (AEGs) recorded from at least one of the two carefully selected LA sites would manifest a rapid, regular rhythm with AEGs of short cycle length (CL) and constant morphology, but a selected right atrial (RA) site would manifest AEGs with irregular CLs and variable morphology. In 44 patients undergoing OHS, AEGs recorded from the epicardial surface of the RA, the LA portion of Bachmann's bundle, and the posterior LA during sustained AF were analysed for regularity of CL and morphology. Sustained AF occurred in 15 of 44 patients. Atrial electrograms were recorded in 11 of 15 patients; 8 of 11 had rapid, regular activation with constant morphology recorded from at least one LA site; no regular AEG sites were present in 3 of 11 patients. Atrial electrograms recorded during sustained POAF frequently demonstrated rapid, regular activation in at least one LA site, consistent with a driver maintaining AF. Published by Oxford University Press on behalf of the European Society of Cardiology 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. CT features of cardio-pericardial masses

    International Nuclear Information System (INIS)

    Vasile, N.; Nicoleau, F.; Mathieu, D.

    1986-01-01

    The results of dynamic computed tomography (CT) in 13 patients with intracardiac filling defects and one with a pericardial lipoma are presented. The intracardiac filling defects were due to thrombus in five cases, myxoma in three, hydatid cysts in three, haemangiopericytoma in one and sarcoma in one. These kinds of lesions are well identified by CT which seems to be superior to echocardiography in the characterisation of the components and in the evaluation of the malignant spreading masses. (orig.)

  1. Frequency analysis of the ECG before and during ventricular fibrillation

    NARCIS (Netherlands)

    Herbschleb, J.N.; Heethaar, R.M.; Tweel, I. van der; Meijler, F.L.

    1980-01-01

    Frequency analysis of cardiac electrograms of dogs with ventricular fibrillation (VF) during complete cardiopulmonary bypass and coronary perfusion showed a power spectrum with a peak around 12 Hz and its higher harmonics, suggesting more organization than generally assumed. As a next step to see

  2. Fibrosis and electrophysiological characteristics of the atrial appendage in patients with atrial fibrillation and structural heart disease

    NARCIS (Netherlands)

    Brakel, T.J. van; Krieken, T. van der; Westra, S.W.; Laak, J.A.W.M. van der; Smeets, J.L.R.M.; Swieten, H.A. van

    2013-01-01

    PURPOSE: This study was conducted to investigate the degree of fibrosis in atrial appendages of patients with and without atrial fibrillation (AF) undergoing cardiac surgery. In addition, we hypothesized that areas of atrial fibrosis can be identified by electrogram fractionation and low voltage for

  3. Gated magnetic resonance imaging of congenital cardiac malformations

    International Nuclear Information System (INIS)

    Fletcher, B.D.; Jocobstein, M.D.; Nelson, A.D.; Riemenschneider, T.A.; Alfidi, R.J.

    1984-01-01

    Magnetic resonance (MR) images of a variety of cardiac malformations in 19 patients aged 1 week to 33 years were obtained using pulse plethysmographic- or ECG-gated spin echo pulse sequences. Coronal, axial, and sagittal images displaying intracardiac structures with excellent spatial and contrast resolution were acquired during systole or diastole. It is concluded that MR will be a valuable noninvasive method of diagnosing congenital heart disease

  4. Intra-cardiac masses in adults: A review of echocardiogram records ...

    African Journals Online (AJOL)

    2012-12-04

    Dec 4, 2012 ... TTE is the clinical procedure of choice for identification of left ventricular thrombi. ... Materials and Methods: We did a retrospective review of our echocardiogram reports from May 2003 to July 2012 ... Although many new.

  5. Electrophysiological performance of a bipolar membrane-coated titanium nitride electrode: a randomized comparison of steroid and nonsteroid lead designs.

    Science.gov (United States)

    Wiegand, U K; Zhdanov, A; Stammwitz, E; Crozier, I; Claessens, R J; Meier, J; Bos, R J; Bode, F; Potratz, J

    1999-06-01

    The aim of this multicenter study was to investigate the performance of a new cardiac pacemaker lead with a titanium nitride cathode coated with a copolymer membrane. In particular, the electrophysiological effect of steroid dissolved in this ion-exchange membrane was evaluated by randomized comparison. Ninety-five patients were randomized either to the 1450 T (n = 51) or the 1451 T ventricular lead (n = 45) and received telemeteral VVI(R) pacemakers with identical diagnostic features. Both leads were bipolar, were passively affixed, and had a porous titanium nitride tip with a surface area of 3.5 mm2. The only difference between the two electrodes was 13 micrograms of dexamethasone added to the 1450 Ts membrane coating. Voltage thresholds (VTH) at pulse durations of 0.25, 0.37, and 0.5 ms, lead impedance, and sensing thresholds were measured at discharge, 2 weeks, 1 month, 3 months, and 6 months after implantation. Mean amplitude and the slew rate from three telemetered intracardiac electrograms, chronaxie-rheobase product, and minimum energy consumption were calculated. After a 6-month follow-up, mean voltage thresholds of 0.65 +/- 0.20 V and 0.63 +/- 0.34 were achieved for the 1450 T lead and 1451 T lead, respectively. As a result, a VTH < 1.0 V was obtained in all patients with 1450 T electrodes and in 97.7% of patients with 1451 T leads after 6 months follow-up. In both electrodes, stable VTH was reached 2 weeks after implantation, and no transient rise in threshold was observed. No differences were observed between the steroid and the nonsteroid group in respect to VTH, chronaxie-rheobase product, minimum energy consumption, and potential amplitude and slew rate. In conclusion, safe and efficient pacing at low pulse amplitudes were achieved with both leads. The tip design, independently of the steroid additive, prevented any energy-consuming increases in the voltage threshold.

  6. Nitric oxide improves the hemodynamic performance of the hypoxic goldfish (Carassius auratus) heart

    DEFF Research Database (Denmark)

    Imbrogno, Sandra; Capria, C.; Tota, Bruno

    2014-01-01

    Goldfish tolerate prolonged and severe hypoxia, thus representing a well-suited model to study the maintenance of cardiac function when O2 availability represents a limiting factor. Using a working heart preparation, we explored the role of the intracardiac nitric oxide synthase (NOS)- derived...... complemented by Western blotting analysis which revealed increased expressions of NOS and hypoxia inducible factor α(HIF-1α). In conclusion, we demonstrated that intracardiac NO/NOS enhances goldfish heart performance, remarkably expanding its hypoxic tolerance....

  7. Role of atrial fibrillation and atrioventricular conduction (including Wolff-Parkinson-White Syndrome) in sudden death

    NARCIS (Netherlands)

    Meijler, F.L.; Tweel, I. van der; Herbschleb, J.N.; Hauer, R.N.W.; Robles de Medina, E.O.

    A short refractory period of the accessory pathway is considered a major threat for sudden death in patients with Wolff-Parkinson-White syndrome and atrial fibrillation. RR interval and QRS signal analysis together with signal analysis of a bipolar high right atrial electrogram were obtained in six

  8. Interventricular dispersion in repolarization causes bifid T waves in dogs with dofetilide-induced long QT syndrome

    NARCIS (Netherlands)

    Meijborg, Veronique M. F.; Chauveau, Samuel; Janse, Michiel J.; Anyukhovsky, Evgeny P.; Danilo, Peter R.; Rosen, Michael R.; Opthof, Tobias; Coronel, Ruben

    2015-01-01

    Long QT2 (LQT2) syndrome is characterized by bifid (or notched) T waves, whose mechanism is not understood. The purpose of this study was to test whether increased interventricular dispersion of repolarization induces bifid T waves. We simultaneously recorded surface ECG and unipolar electrograms at

  9. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Andrew K. Roy

    2016-01-01

    Full Text Available Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS. Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74, which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure.

  10. Cardiovascular nuclear medicine in infancy and childhood

    International Nuclear Information System (INIS)

    Ogawa, Kyoichi; Ishii, Noboru; Miyata, Tooru; Nakamura, Takashi; Hasegawa, Mamoru

    1979-01-01

    Radionuclide angiocardiography and lung scanning in the diagnosis of congenital heart disease in infants and children are introduced and discussed. Recently developed radionuclide angiocardiography is a safe and useful method in the detection and quantification of intracardiac shunts, together with for the measurement of transit times, left ventricular ejection fraction and cardiac output. Lung scanning is useful in the evaluation of pulmonary blood flow distribution in the congenital heart disease such as ventricular septal defect (VSD), tetralogy of Fallot (TOF), etc. To decide the limitation of operative indication for VSD with severe pulmonary hypertension, the ratio of pulmonary blood flow distribution in upper to lower lung filed above 1.2, the right to left shunt ratio above 0.25, and deranged blood flow distribution on bilateral lungs are useful as the criteria. In the follow up study after intracardiac repair of TOF, lung scanning reflects the residua and sequalae such as pulmonary stenosis, pulmonary insufficiency, pulmonary hypertension, peripheral pulmonary stenosis and anomalous dilatation of the right ventricular outflow tract. (author)

  11. Effect of increased left ventricle mass on ischemia assessment in electrocardiographic signals: rabbit isolated heart study

    Czech Academy of Sciences Publication Activity Database

    Ronzhina, M.; Olejníčková, Veronika; Stračina, T.; Nováková, M.; Janoušek, O.; Hejč, J.; Kolářová, J.; Hlaváčová, M.; Paulová, H.

    2017-01-01

    Roč. 17, Aug 4 (2017), č. článku 216. ISSN 1471-2261 Institutional support: RVO:67985823 Keywords : myocardial ischemia detection * increased left ventricular mass * electrogram * ROC analysis * isolated heart * rabbit Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery OBOR OECD: Physiology (including cytology) Impact factor: 1.832, year: 2016

  12. Intracardiac metastasis originated from chondrosarcoma.

    Science.gov (United States)

    Maurea, Nicola; Ragone, Gianluca; Coppola, Carmela; Caronna, Antonietta; Tocchetti, Carlo G; Agozzino, Lucio; Apice, Gaetano; Iaffaioli, Rosario V

    2017-05-01

    Primary cardiac tumors are extremely rare. By comparison, metastatic involvement of the heart is over 20 times more common and has been reported in autopsy series in up to one in five patients dying of cancer. Cardiac metastasis of chondrosarcoma is absolutely not frequent. In the recent literature, a cardiac metastasis from chondrosarcoma has never been described. We report the case of an 18-year-old man with a diagnosis of cardiac metastasis that originated from a left scapular chondrosarcoma. Chondrosarcoma is a skeletal tumor with various grades of malignancy, rapidly evolving, and with a strong tendency to metastasize, with low responsiveness to chemotherapy. The onset of characteristic systemic symptoms in the late stage of the disease led to the diagnosis of a mass localized in the right atrium. Management and differential diagnosis of infective heart lesions were also very complex in a rapidly evolving life-threatening condition.

  13. Intracardiac tromboembolism during liver transplantation.

    Science.gov (United States)

    Longo, S; Palacios, M; Tinti, M E; Siri, J; de Brahi, J I; Cabrera Shulmeyer, M C

    2018-03-20

    We describe a case of intraoperative cardiac trombosis during orthotopic liver transplant surgery that resulted in intraoperative death. By using transesophageal echocardiography, the cause of the descompensation of the patient could be determined and the mechanism of trombus migration from thrombi from the venous circulation to the left heart was accurately observed. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. A novel intra-operative, high-resolution atrial mapping approach.

    Science.gov (United States)

    Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S

    2015-12-01

    A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.

  15. Cardiac hydatic cyst. Studied case by US, CT and MR. Quiste hidatidico cariaco. Presentacion de un caso estudiado por US, TC, y RM

    Energy Technology Data Exchange (ETDEWEB)

    Led, A.; Mazas-Artasona, L.; Cabello, A.; Arconada, J.A.; Balmaseda, C. (Complejo Hospitalario de la S.S. San Millan-San Pedro. Logrono (Spain))

    1993-01-01

    We present a cardiac hydatid cyst in a seventeen year-old male, who was operated on, five years ago, for hydatid disease in the lung and in the liver. In the follow-up a Computed Tomography was carried out in which an intracardiac rounded image was visible, showing to be non-enhancing after endovenous contrast injection. Due to this characteristic, the history of hydatid disease and the high incidence of this entity in our country, an intracardiac hydatid cyst was suspected. The diagnosis was reinforced by real-time echocardiography and Magnetic Nuclear Resonance, and confirmed in the surgical intervention. (Author)

  16. Voltage gradient mapping and electrophysiologically guided cryoablation in children with AVNRT.

    Science.gov (United States)

    Drago, Fabrizio; Battipaglia, Irma; Russo, Mario Salvatore; Remoli, Romolo; Pazzano, Vincenzo; Grifoni, Gino; Allegretti, Greta; Silvetti, Massimo Stefano

    2018-04-01

    Recently, voltage gradient mapping of Koch's triangle to find low-voltage connections, or 'voltage bridges', corresponding to the anatomic position of the slow pathway, has been introduced as a method to ablate atrioventricular nodal reentry tachycardia (AVNRT) in children. Thus, we aimed to assess the effectiveness of voltage mapping of Koch's triangle, combined with the search for the slow potential signal in 'low-voltage bridges', to guide cryoablation of AVNRT in children. From June 2015 to May 2016, 35 consecutive paediatric patients (mean age 12.1 ± 4.5 years) underwent 3D-guided cryoablation of AVNRT at our Institution. Fifteen children were enrolled as control group (mean age 14 ± 4 years). A voltage gradient mapping of Koch's triangle was obtained in all patients, showing low-voltage connections in all children with AVNRT but not in controls. Prior to performing cryoablation, we looked for the typical 'hump and spike' electrogram, generally considered to be representative of slow pathway potential within a low-voltage bridge. In all patients the 'hump and spike' electrogram was found inside bridges of low voltage. Focal or high-density linear lesions, extended or not, were delivered guided by low-voltage bridge visualization. Acute success rate was 100%, and no recurrence was reported at a mean follow-up of 8 ± 3 months. Voltage gradient mapping of Koch's triangle, combined with the search for the slow potential signal in low-voltage bridges, is effective in guiding cryoablation of AVNRT in paediatric patients, with a complete acute success rate and no AVNRT recurrences at mid-term follow-up.

  17. Correção intracardíaca da tetralogia de Fallot no primeiro ano de vida: resultados a curto e médio prazos Intracardiac correction of tetralogy of Fallot in the first year of life: short-term and midium-term results

    Directory of Open Access Journals (Sweden)

    Fernando Ribeiro de Moraes Neto

    2008-06-01

    Full Text Available OBJETIVO: Avaliar os resultados a curto e médio prazos da correção intracardíaca da tetralogia de Fallot no primeiro ano de vida. MÉTODOS: De janeiro de 1996 a outubro de 2004, 67 crianças com idade variando de 1 a 11 meses (média: 7,2 meses e pesando entre 4 a 10 quilos (média: 7,1 kg foram eletivamente submetidas a correção intracardíaca da tetralogia de Fallot. A cirurgia foi realizada com circulação extracorpórea convencional e hipotermia moderada. Ventriculotomia direita foi realizada em 60 (89,5% casos e em sete (10,5% utilizou-se a abordagem do defeito pela via atriopulmonar. RESULTADOS: O tempo de circulação extracorpórea variou de 35 a 147 minutos (média:78,8 ± 21 minutos, e o tempo de pinçamento da aorta variou de 25 a 86 minutos (média: 51,8 ± 15,6 minutos. Ampliação transanular da via de saída do ventrículo direito foi necessária em 50 (64,1% casos. O gradiente entre o ventrículo direito e a artéria pulmonar, após a correção, variou de 0 a 54 mmHg (média: 15,5 ± 10,8 mmHg. Ocorreram dois (2,98% óbitos no pós-operatório imediato. O seguimento tardio variou de 7 a 115 meses (média: 44,0 ± 35 meses. Houve uma morte tardia não-cardíaca. Todos os outros pacientes estão assintomáticos. A curva de sobrevida actuarial, incluindo a mortalidade operatória, revelou que a probabilidade de sobrevida, 12 anos após a operação, é de 97%. Dez pacientes foram avaliados por angiorresonânia magnética nuclear. CONCLUSÕES: A correção intracardíaca da tetralogia de Fallot no primeiro ano de vida pode ser feita com baixas morbidade e mortalidade e bons resultados tardios.OBJECTIVE: To evaluate short-term and medium-term results of intracardiac correction of Tetralogy of Fallot in the first year of life. METHODS: From January 1996 to October 2004, 67 consecutive infants ranging in age from 1 to 11 months (mean: 7.2 months and weighing from 4 to 10 kilograms (mean: 7.1 kilograms underwent elective total

  18. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  19. Periodontal Disease Is an Independent Predictor of Intracardiac Calcification

    Directory of Open Access Journals (Sweden)

    Gregg S. Pressman

    2013-01-01

    Full Text Available Background. Periodontitis is the most common chronic inflammatory condition worldwide and is associated with incident coronary disease. Hypothesis. We hypothesized that periodontal disease would also be associated with cardiac calcification, a condition which shares many risk factors with atherosclerosis and is considered a marker of subclinical atherosclerosis. Methods. Cross-sectional study at two sites (USA and Japan involving subjects with both clinical echocardiograms and detailed dental examinations. Semiquantitative scoring systems were used to assess severity of periodontal disease and echocardiographic calcification. Results. Fifty-six of 73 subjects (77% had cardiac calcifications, and 51% had moderate to severe periodontal disease (score > 2. In unadjusted analysis, a significant relationship between periodontal score and cardiac calcification (Spearman rho = 0.4, P=0.001 was noted, with increases in mean calcification score seen across increasing levels of periodontal disease. On multivariate logistic regression, adjusted for age, gender, race, glomerular filtration rate, and traditional risk factors, this association remained significant (P=0.024. There was no significant interaction by study site, race, or gender. Conclusions. In a multiracial population, we found a significant association between the degree of periodontal disease, a chronic inflammatory condition, and cardiac calcification. Further, higher periodontal scores were associated with greater degrees of calcification.

  20. Detection of thrombi by 111In-oxine platelet scintigraphy

    International Nuclear Information System (INIS)

    Makino, Katsutoshi; Yamamuro, Masashi; Ichikawa, Takehiko; Futagami, Yasuo; Konishi, Tokuji; Nakano, Takeshi; Takezawa, Hideo

    1985-01-01

    For 52 patients with cardiac disease and 11 patients with vascular disease, In-111-oxine platelet scintigraphy was performed to assess its clinical usefulness for detecting thrombi. Using Hayashida's method, platelets were separated in 43 ml peripheral blood, washed and labeled with 1 mCi In-111-oxine. In addition to planar images in the anterior, 45 deg left anterior oblique and left lateral views, single photon emission computed tomography (SPECT) was performed in some cases by rotating a dual gamma camera 24 and 72 hours after labeled platelet injection. The functions of platelet and coagulability were examined 36 hours after the injection of labeled platelets. Medical therapy was not changed during this study. Intracardiac thrombi were documented in 16 of 52 cases with cardiac disease and intravascular thrombi in 10 cases with vascular disease by angiography, CT and two-dimensional echocardiography. Positive images were obtained in 10 cases with cardiac disease and in eight cases with vascular disease by scintigraphy. Therefore, sensitivity, specificity, and overall accuracy were 63 %, 100 % and 88 % in intracardiac thrombi; 80 %, 100 % and 82 % in intravascular thrombi; and totally 69 %, 100 % and 87 %, respectively. In the detection of intracardiac thrombi by scintigraphy, the sensitivity seemed to be lower and the specificity higher than those by other graphic studies. In 52 cases with cardiac disease, five out of six cases with false negative images had received antiplatelet and/or anticoagulant drugs, and in these cases, platelet and coagulation functions tended to be decreased compared with those of true positive cases or true negative cases. We conclude that positive images in scintigraphy indicate the existence of growing thrombi, and that In-111-oxine platelet scintigraphy has clinical usefulness, not only for detecting thrombi, but for estimating platelet activity and effect of medical therapy. (author)

  1. Echocardiography-guided Radiofrequency Catheter Ablation of Atrioventricular Node and VVI Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    T Guo

    2014-05-01

    Full Text Available Objective: This study is to evaluate the feasibility and safety of intracardiac radiofrequency catheter ablation (RFCA of the atrioventricular node (AVN and pacemaker implantation using transthoracic echocardiography. Methods: Eleven patients – six males and five females (mean age 66 years – with persistent or permanent atrial fibrillation/atrial flutter received RFCA of AVN and VVI pacemaker implantation (paces and senses the ventricle and is inhibited if it senses ventricular activity. Under transthoracic echocardiography, the electrode catheters were positioned intracardiac, and target ablation was performed, with the permanent pacemaking catheter in the left subclavian vein and the ablation catheter in the right femoral vein. The multi-view imaging and dynamic observation applied during the stable AV dissociation were successful. Results: Atrioventricular node ablation and permanent pacemaker implantation in 11 patients were completed successfully without X-ray exposure. The operation success rate was 100%. All patients recovered well within the follow-up period. Conclusions: Radiofrequency catheter ablation of AVN and VVI pacemaker implantation under transthoracic echocardiography guidance is a safe, easy and feasible approach. This procedure could be an important supplemental measure to catheter ablation of arrhythmia under routine X-ray fluoroscopy.

  2. Cerebral injury after cardiac surgery: identification of a group at extraordinary risk. Multicenter Study of Perioperative Ischemia Research Group (McSPI) and the Ischemia Research Education Foundation (IREF) Investigators.

    Science.gov (United States)

    Wolman, R L; Nussmeier, N A; Aggarwal, A; Kanchuger, M S; Roach, G W; Newman, M F; Mangano, C M; Marschall, K E; Ley, C; Boisvert, D M; Ozanne, G M; Herskowitz, A; Graham, S H; Mangano, D T

    1999-03-01

    Cerebral injury after cardiac surgery is now recognized as a serious and costly healthcare problem mandating immediate attention. To effect solution, those subgroups of patients at greatest risk must be identified, thereby allowing efficient implementation of new clinical strategies. No such subgroup has been identified; however, patients undergoing intracardiac surgery are thought to be at high risk, but comprehensive data regarding specific risk, impact on cost, and discharge disposition are not available. We prospectively studied 273 patients enrolled from 24 diverse US medical centers, who were undergoing intracardiac and coronary artery surgery. Patient data were collected using standardized methods and included clinical, historical, specialized testing, neurological outcome and autopsy data, and measures of resource utilization. Adverse outcomes were defined a priori and determined after database closure by a blinded independent panel. Stepwise logistic regression models were developed to estimate the relative risks associated with clinical history and intraoperative and postoperative events. Adverse cerebral outcomes occurred in 16% of patients (43/273), being nearly equally divided between type I outcomes (8.4%; 5 cerebral deaths, 16 nonfatal strokes, and 2 new TIAs) and type II outcomes (7.3%; 17 new intellectual deterioration persisting at hospital discharge and 3 newly diagnosed seizures). Associated resource utilization was significantly increased--prolonging median intensive care unit stay from 3 days (no adverse cerebral outcome) to 8 days (type I; P<0.001) and from 3 to 6 days (type II; P<0.001), and increasing hospitalization by 50% (type II, P=0.04) to 100% (type I, P<0.001). Furthermore, specialized care after hospital discharge was frequently necessary in those with type I outcomes, in that only 31% returned home compared with 85% of patients without cerebral complications (P<0.001). Significant risk factors for type I outcomes related primarily

  3. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

    Energy Technology Data Exchange (ETDEWEB)

    Mory, Cyril, E-mail: cyril.mory@philips.com [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Auvray, Vincent; Zhang, Bo [Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Grass, Michael; Schäfer, Dirk [Philips Research, Röntgenstrasse 24–26, D-22335 Hamburg (Germany); Chen, S. James; Carroll, John D. [Department of Medicine, Division of Cardiology, University of Colorado Denver, 12605 East 16th Avenue, Aurora, Colorado 80045 (United States); Rit, Simon [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Centre Léon Bérard, 28 rue Laënnec, F-69373 Lyon (France); Peyrin, Françoise [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); X-ray Imaging Group, European Synchrotron, Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Douek, Philippe; Boussel, Loïc [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Hospices Civils de Lyon, 28 Avenue du Doyen Jean Lépine, 69500 Bron (France)

    2014-02-15

    Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.

  4. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

    International Nuclear Information System (INIS)

    Mory, Cyril; Auvray, Vincent; Zhang, Bo; Grass, Michael; Schäfer, Dirk; Chen, S. James; Carroll, John D.; Rit, Simon; Peyrin, Françoise; Douek, Philippe; Boussel, Loïc

    2014-01-01

    Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection

  5. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  6. Nephrotic syndrome: a rare cause of acute coronary syndrome in a child

    International Nuclear Information System (INIS)

    Khan, J.A.; Shamsi, F.

    2012-01-01

    Patients with nephrotic syndrome are at risk of developing thrombosis in both veins and arteries. Various manifestations in different organs have been reported. Thrombi in heart seen, associated with multi organ thrombosis have been reported on autopsy earlier, but only once in a living patient with nephrotic syndrome. Here, we report a 13 years old boy with steroid-resistant nephrotic syndrome, who developed an asymptomatic but potentially hazardous large intracardiac thrombus. The child developed nephrotic syndrome at the age of 9 years and had multiple recurrences. At the age of 13 years, he developed myocardial infarction (MI) due to embolism from a large intracardiac thrombus. Later on, he was treated with heparin and warfarin anticoagulation. (author)

  7. Motion Mode and Two Dimensional Echocardiographic Measurements of Cardiac Dimensions of Indonesian Mongrel Dogs

    Directory of Open Access Journals (Sweden)

    DENI NOVIANA

    2011-03-01

    Full Text Available Prevalence of heart disease in dogs was very high and required early diagnosis through physical examination, electrocardiogram, and echocardiography. Normal reference values of echocardiography are highly breedspecific and need for comparison and evaluation of dogs suspected with heart disease. Therefore the aim of this study was to establish normal reference echocardiographic values for Indonesian mongrel dogs, specifically to find out intracardiac dimensions, wall thickness, and fractional shortening. Motion-mode and two-dimensional echocardiography from right parasternal short axis and long axis view were performed on nine clinically healthy dogs consisting of five males and four males. The results showed that wall thickness and fractional shortening of Indonesia mongrel dogs were higher compared with those in the other breed that have the same average weight. As opposite, the intracardiac dimensions and lumen dimensions of aorta and left atrial diameter were smaller. These differences might occur due to factors other than the dog's habits and functions such as working and hunting, but can also be caused by the existence of breed differences. There was no significant difference between male and female dogs in terms of intracardiac dimension systole (P = 0.53, diastole (P = 0.38, fractional shortening (P = 0.053, and the ratio of aorta and left atrial diameter (P = 0.06.

  8. Normal Values for Heart Electrophysiology Parameters of Healthy Swine Determined on Electrophysiology Study.

    Science.gov (United States)

    Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef

    2016-01-01

    Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.

  9. Intracardiac and intracerebral thrombosis associated with ...

    African Journals Online (AJOL)

    Although thromboembolic events in nephrotic syndrome (NS) are seen less often in ... occurs, causing atherosclerosis and vascular thrombosis. Mutations .... Cranial diffusion magnetic resonance (MR) and MR angiography showed brain.

  10. REPERFUSION THERAPY IN ACUTE CORONARY SYNDROME WITH ST SEGMENT ELEVATION

    Directory of Open Access Journals (Sweden)

    A. L. Alyavi

    2016-01-01

    Full Text Available Aim. To compare effect of percutaneous balloon angioplasty (PCA and a systemic thrombolysis (STL on the central and intracardiac hemodynamics in patients with acute coronary syndrome (ACS with ST segment elevation.Material and methods. 80 patients with ACS with ST segment elevation were included in the study. Patients were split into 2 groups depending on reperfusion strategy. PCA was performed in 55 patients (first group. 25 patients of the second group had STL with Streptokinase, i/v, 1 500 000 units per hour. Echocardiography was performed in all patients at admission and after 3 and 7 days of treatment to evaluate intracardiac hemodynamics.Results. Both reperfusion methods significantly increase of ejection fraction (EF and maximal output speed of left ventricle (LV. Increase of LV EF in patients after PCA was higher than this in patients after STL. PCA improved LV diastolic function; STL did not change this characteristic. After PCA working diagnosis of ACS was transformed to the following final diagnosis: acute myocardial infarction (AMI with Q, AMI without Q and unstable angina in 37,5, 30,4 and 32,1% of patients, respectively. After STL diagnosis of AMI with Q was defined in all patients.Conclusion. PCA in patients with ACS with ST segment elevation results in fast improvement of global systolic and diastolic LV function. Besides, PCA prevents AMI with Q in a half of these patients.

  11. Early Heparin Administration Reduces Risk for Left Atrial Thrombus Formation during Atrial Fibrillation Ablation Procedures

    Directory of Open Access Journals (Sweden)

    Stefan Asbach

    2011-01-01

    Full Text Available Objective. Despite the use of anticoagulation during left atrial (LA ablation procedures, ischemic cerebrovascular accidents (CVAs are recognized as a serious complication. Heparin is usually given after safe transseptal access has been obtained, resulting in a short unprotected dwell time of catheters within the LA, which may account for CVAs. We investigated the frequency of CVAs and LA thrombus formation as detected by intracardiac ultrasound (ICE depending on the timing of heparin administration. Methods and Results. Sixty LA ablation procedures with the use of ICE were performed in 55 patients. Patients were grouped by heparin administration after (Group I, =13 and before (Group II, =47 transseptal access. Group I patients were younger (56.6±13.7 versus 65.9±9.9 years, =.01; other clinical and echocardiographic characteristics did not differ between groups. Early thrombus formation was observed in 2 (15.4% of group I patients as compared to 0% of group II patients (=.04. One CVA (2.1% occurred in one group II patient without prior thrombus detection, and none occurred in group I patients (=ns. Conclusion. Early administration of heparin reduces the risk of early intracardiac thrombus formation during LA ablation procedures. This did not result in reduced rate of CVAs.

  12. Radionuclide detection and differential diagnosis of left-to-right cardiac shunts by analysis of time-activity curves

    International Nuclear Information System (INIS)

    Kim, Ok-Hwa

    1986-01-01

    The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity histograms of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intracardiac or extracardiac shunts, and moreover, with this method the localization of the shunts level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was hight than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. (J.P.N.)

  13. Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans.

    Science.gov (United States)

    Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai

    2016-10-01

    The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.

  14. Recurrent left ventricular myxoma presenting as cerebrovascular accidents in a teenage girl.

    Science.gov (United States)

    Vermeulen, Tom; Conraads, Viviane M; Vrints, Christiaan; Rodrigus, Inez E

    2009-12-01

    Myxoma cordis is the most frequent primary cardiac tumour in adults. Paediatric primary cardiac tumours are rare, the most common type being rhabdomyoma. Atrial and ventricular myxomas occur infrequently in the paediatric age group. Intracardiac myxomas are seen with an estimated incidence of 0.5 per million population per year. Approximately 70% of the affected patients are of female gender. Recurrences are rare (1.3%). Asymptomatic recurrences are observed in young patients who have a familial history of tumour or multifocal myxomas. Although rare, cardiac aetiology (atrial fibrillation, intracardiac thrombi, patent foramen ovale, myxoma, endocarditis) should be considered. In children presenting with central neurological symptoms, a cardiac aetiology has to be considered. We describe a rare case of an 18-year-old girl presenting with a recurrent left ventricular myxoma, accompanied by neurological deficits.

  15. Bosentan therapy in patients with Eisenmenger syndrome : a multicenter, double-blind, randomized, placebo-controlled study

    NARCIS (Netherlands)

    Galiè, Nazzareno; Beghetti, Maurice; Gatzoulis, Michael A; Granton, John; Berger, Rolf M.F.; Lauer, Andrea; Chiossi, Eleonora; Landzberg, Michael

    2006-01-01

    BACKGROUND: Eisenmenger syndrome is characterized by the development of pulmonary arterial hypertension with consequent intracardiac right-to-left shunt and hypoxemia in patients with preexisting congenital heart disease. Because Eisenmenger syndrome is associated with increased endothelin

  16. Trafficking of Metastatic Breast Cancer Cells in Bone

    National Research Council Canada - National Science Library

    Mastro, Andrea M

    2004-01-01

    ... metaphyses. Human breast cancer cells that express green fluorescent protein (GFP-MDA-MB 231) will be inoculated into athymic mice by intracardiac injection and femurs harvested at various times from 1 hour to 6 weeks later...

  17. Comparative Study of Clonidine versus Lignocaine for Attenuation of ...

    African Journals Online (AJOL)

    rate, Systolic blood pressure, diastolic blood pressures were significantly more in group A. There was no difference in sedation score between ... blood volume, intracardiac filling pressures may be elevated ..... baroreceptor sensivity.[17‑19] So ...

  18. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    OpenAIRE

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T ...

  19. Platypnea and orthodeoxia associated with Pneumocystis jiroveci and Cytomegalovirus pneumonia: a case report

    Directory of Open Access Journals (Sweden)

    Bikas Christoforos

    2009-12-01

    Full Text Available Abstract Introduction Platypnea-orthodeoxia is an uncommon syndrome characterized by dyspnea and deoxygenation accompanying a change to a sitting or standing posture from a recumbent position. It is usually related to interatrial communications, although several other disorders associated with platypnea-orthodeoxia syndrome have been reported. However, the precise mechanisms are unknown. Case presentation We present the case of a 75-year-old Caucasian woman with chronic renal failure due to vasculitis who was admitted with fever and respiratory failure. She was found to have both Pneumocystis jiroveci and Cytomegalovirus pneumonia. She was HIV negative. Severe platypnea and orthodeoxia were major features of her illness with no history of respiratory, liver or cardiac disease. Further investigation with contrast echocardiography revealed no intracardiac or intrapulmonary shunts. Although one case involving Pneumocystis jiroveci pneumonia and platypnea has been previously reported, to the best of our knowledge, this is the first time that two opportunistic pathogens have been accompanied by platypnea and orthodeoxia. As both lung bases were predominantly affected and no obvious explanation was found, platypnea and orthodeoxia were attributed to significant areas of low or zero ventilation/perfusion (V/Q ratio. Conclusion Platypnea-orthodeoxia is a rare and usually underestimated syndrome. Intracardiac shunts and anatomic pulmonary vascular shunts are the most common etiologic associations. However, if a detailed examination reveals no obvious intracardiac or intrapulmonary shunting combined with extensive pulmonary lesions, then severe V/Q mismatching should be considered as the probable explanation.

  20. Diagnostic value of imaging in infective endocarditis : a systematic review

    NARCIS (Netherlands)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of

  1. An unusual case of multiple self-inflicted punctures to the precordium

    LENUS (Irish Health Repository)

    Borhan, F

    2017-06-01

    Sewing needles, albeit a rare case of penetrating cardiac injury, are potentially life-threatening. We report a case of successful intra-cardiac needle removal from a 32 year old who inserted multiple needles into the chest and abdomen.

  2. New Substrate-Guided Method of Predicting Slow Conducting Isthmuses of Ventricular Tachycardia: Preliminary Analysis to the Combined Use of Voltage Limit Adjustment and Fast-Fourier Transform Analysis.

    Science.gov (United States)

    Kuroki, Kenji; Nogami, Akihiko; Igarashi, Miyako; Masuda, Keita; Kowase, Shinya; Kurosaki, Kenji; Komatsu, Yuki; Naruse, Yoshihisa; Machino, Takeshi; Yamasaki, Hiro; Xu, Dongzhu; Murakoshi, Nobuyuki; Sekiguchi, Yukio; Aonuma, Kazutaka

    2018-04-01

    Several conducting channels of ventricular tachycardia (VT) can be identified using voltage limit adjustment (VLA) of substrate mapping. However, the sensitivity or specificity to predict a VT isthmus is not high by using VLA alone. This study aimed to evaluate the efficacy of the combined use of VLA and fast-Fourier transform analysis to predict VT isthmuses. VLA and fast-Fourier transform analyses of local ventricular bipolar electrograms during sinus rhythm were performed in 9 postinfarction patients who underwent catheter ablation for a total of 13 monomorphic VTs. Relatively higher voltage areas on an electroanatomical map were defined as high voltage channels (HVCs), and relatively higher fast-Fourier transform areas were defined as high-frequency channels (HFCs). HVCs were classified into full or partial HVCs (the entire or >30% of HVC can be detectable, respectively). Twelve full HVCs were identified in 7 of 9 patients. HFCs were located on 7 of 12 full HVCs. Five VT isthmuses (71%) were included in the 7 full HVC+/HFC+ sites, whereas no VT isthmus was found in the 5 full HVC+/HFC- sites. HFCs were identical to 9 of 16 partial HVCs. Eight VT isthmuses (89%) were included in the 9 partial HVC+/HFC+ sites, whereas no VT isthmus was found in the 7 partial HVC+/HFC- sites. All HVC+/HFC+ sites predicted VT isthmus with a sensitivity of 100% and a specificity of 80%. Combined use of VLA and fast-Fourier transform analysis may be a useful method to detect VT isthmuses. © 2018 American Heart Association, Inc.

  3. Intra-cardiac echocardiography in alcohol septal ablation

    DEFF Research Database (Denmark)

    Cooper, Robert M; Shahzad, Adeel; Newton, James

    2015-01-01

    Alcohol septal ablation (ASA) in hypertrophic obstructive cardiomyopathy reduces left ventricular outflow tract gradients. A third of patients do not respond; inaccurate localisation of the iatrogenic infarct can be responsible. Transthoracic echocardiography (TTE) using myocardial contrast can...

  4. Intercostal drainage tube or intracardiac drainage tube?

    Directory of Open Access Journals (Sweden)

    N Anitha

    2016-01-01

    Full Text Available Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  5. Intercostal drainage tube or intracardiac drainage tube?

    Science.gov (United States)

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  6. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

    NARCIS (Netherlands)

    Tjong, F. V. Y.; Brouwer, T. F.; Smeding, L.; Kooiman, K. M.; de Groot, J. R.; Ligon, D.; Sanghera, R.; Schalij, M. J.; Wilde, A. A. M.; Knops, R. E.

    2016-01-01

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and

  7. Cardiovascular fluid dynamics. Methods for flow and pressure field analysis from magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ebbers, T.

    2001-01-01

    Cardiovascular blood flow is highly complex and incompletely understood. Blood flow patterns are expected to influence the opening and closing of normal and prosthetic heart valves, the efficiency of cardiac filling and ejection, and the resistance to thrombus formation within the heart. Conventional diagnostic techniques are poorly suited to the study of the three-dimensional (3D) blood flow patterns in the heart chambers and large vessels. Noninvasive methods have also been inadequate in studying intracardiac pressure differences, which are the driving force of flow and are critical in the evaluation of many cardiovascular abnormalities. This thesis focuses on the development of non-invasive methods for analysis of 3D cardiovascular blood flow. Simultaneous study of cardiovascular fluid dynamics allowed knowledge exchange across the two disciplines, facilitating the development process and broadening the applicability of the methods. A time-resolved 3D phase-contrast Magnetic Resonance Imaging (MRI) technique was used to acquire the velocity vector field in a 3D volume encompassing the entire heart or a large vessel. Cardiovascular blood flow patterns were visualized by use of particle traces, which revealed, for instance, vortical flow patterns in the left atrium. By applying the Navier-Stokes equation along a user-defined line in the 3D velocity vector field, the relative pressure could be obtained as an excellent supplement to the flow pattern visualization. Using a delineation of the blood pool, the time-varying 3D relative pressure field in the human left ventricle was obtained from the velocity field by use of the pressure Poisson equation. A delineation of the heart muscle, a task that is almost impossible to perform on 3D MRI either automatically or manually, was also achieved by usage of particle traces. This segmentation allows automatic calculation of the 3D relative pressure field, as well as calculation of well-established parameters such as

  8. Cardiovascular fluid dynamics. Methods for flow and pressure field analysis from magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ebbers, T

    2001-05-01

    Cardiovascular blood flow is highly complex and incompletely understood. Blood flow patterns are expected to influence the opening and closing of normal and prosthetic heart valves, the efficiency of cardiac filling and ejection, and the resistance to thrombus formation within the heart. Conventional diagnostic techniques are poorly suited to the study of the three-dimensional (3D) blood flow patterns in the heart chambers and large vessels. Noninvasive methods have also been inadequate in studying intracardiac pressure differences, which are the driving force of flow and are critical in the evaluation of many cardiovascular abnormalities. This thesis focuses on the development of non-invasive methods for analysis of 3D cardiovascular blood flow. Simultaneous study of cardiovascular fluid dynamics allowed knowledge exchange across the two disciplines, facilitating the development process and broadening the applicability of the methods. A time-resolved 3D phase-contrast Magnetic Resonance Imaging (MRI) technique was used to acquire the velocity vector field in a 3D volume encompassing the entire heart or a large vessel. Cardiovascular blood flow patterns were visualized by use of particle traces, which revealed, for instance, vortical flow patterns in the left atrium. By applying the Navier-Stokes equation along a user-defined line in the 3D velocity vector field, the relative pressure could be obtained as an excellent supplement to the flow pattern visualization. Using a delineation of the blood pool, the time-varying 3D relative pressure field in the human left ventricle was obtained from the velocity field by use of the pressure Poisson equation. A delineation of the heart muscle, a task that is almost impossible to perform on 3D MRI either automatically or manually, was also achieved by usage of particle traces. This segmentation allows automatic calculation of the 3D relative pressure field, as well as calculation of well-established parameters such as

  9. 75 FR 6403 - National Center for Health Statistics (NCHS), Classifications and Public Health Data Standards...

    Science.gov (United States)

    2010-02-09

    ...-10-PCS updates Application of Collagen Based Tissue Sealant Patches Biopsy of Soft Tissue Mass Central Venous Catheter Placement Using Intra-Atrial Electrocardiographic Guidance Circulating Tumor Cell Enumeration, Magnetic Closed Chest Intra-cardiac Mitral Valve Repair Continuous Glucose Monitoring Fat Graft...

  10. Cardiopulmonary bypass and hemostasis

    NARCIS (Netherlands)

    Eijsman, Leon

    1992-01-01

    In chapter 1, we recalled that intracardiac defects can only be corrected when cardiopulmonary circulation is maintained by extracorporeal criculation and ventilation. To prevent clot formation in this artificial circuit, the socalled cardiopulmonary bypass (CPB), we completely depend on the

  11. Incidência de trombo intracardíaco e de tromboembolismo nos três primeiros meses após o implante de bioprótese valvar Incidence of intracardiac thrombus and thromboembolism in the first three months after bioprosthetic valve implantation

    Directory of Open Access Journals (Sweden)

    Auristela Isabel de Oliveira Ramos

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a incidência de trombo intracardíaco e de tromboembolismo nos três primeiros meses após a troca valvar por bioprótese e identificar fatores de risco para a formação de trombo. MÉTODO:Incluídos 184 pacientes, entre 15 e 75 anos de idade, submetidos a implante de bioprótese e realizados ecocardiogramas transtorácico e transesofágico (ETE na fase hospitalar, média 8,4±3 dias, e três meses após, média 97,4±21,7 dias. RESULTADOS: Incidência de trombo foi significativamente mais elevada nos pacientes com prótese em posição mitral ou mitroaórtica (21,0% do que em posição aórtica (2,8%, pOBJECTIVE: To assess the incidence of intracardiac thrombus and thromboembolism in the first 3 months after bioprosthetic valve replacement and to identify the risk factors for thrombus formation. METHODS: The study comprised 184 patients, aged between 15 and 75 years, who underwent bioprosthetic valve implantation. Transthoracic and transesophageal (TEE echocardiographies were performed in the in-hospital phase (mean, 8.4±3 days and after 3 months (mean, 97.4±21.7 days. RESULTS: The incidence of thrombus was significantly greater in patients with a prosthesis in the mitral or mitroaortic position (21.0% than in those with a prosthesis in the aortic position (2.8%, P<0.001. The multiple logistic regression identified the prosthesis in the mitral or mitroaortic position as the only independent variable for thrombus formation. On the 3-month follow-up, TEE showed a thrombus in 35 (20.7% of the 169 patients on echocardiographic assessment, 31.7% in mitral patients and 3.1% in aortic patients, P<0.001. In the third month, the multiple logistic regression also identified the prosthesis in the mitral or mitroaortic position as the only independent variable for thrombus formation. During the 3-month follow-up, 3 (1.6% patients died and 8 (4.3% experienced embolic phenomena, all in the cerebral territory. CONCLUSION: The incidence

  12. Atrial myxoma-related embolism resulting in acute limb ischaemia in ...

    African Journals Online (AJOL)

    Although atrial myxomas are uncommon, a thorough investigation of patients presenting with acute peripheral ischaemic .... reported.[9] Large left atrial tumours impairing intracardiac blood flow can ... In the case described here, obstruction of the mitral valve by the myxoma ... operation, preventing histological confirmation.

  13. Dissemineret B-celle-lymfom med kardiel involvering ved hiv-infektion

    DEFF Research Database (Denmark)

    Ullerup-Aagaard, Henriette; Müllertz, Katrine Mikala

    2012-01-01

    A 44 year-old Somali woman was admitted with chest pain, shortness of breath and weight loss. A transthoracic echocardiography showed extensive intracardiac tumour masses. A transvenous biopsy was performed yielding the diagnosis diffuse large B-cell lymphoma. Thoracic and abdominal computed...

  14. [Results of the use of pumpan preparation in the treatment of severe forms of angina pectoris].

    Science.gov (United States)

    Parshina, S S; Golovacheva, T V; Afanas'eva, T N; Panchenko, O V; Baldina, A A; Starostina, N V; Lial'chenko, I F; Egorova, L P

    2000-01-01

    To assess validity of adjuvant use of pumpan, a homeopathic compound, in patients with unstable angina pectoris and angina of effort (functional class III-IV) receiving conventional treatment. A direct open controlled trial for 15 months performed initially in hospital, then outpatiently, covered 49 patients with severe angina. Examination of the patients included evaluation of clinical condition and the disease course, lipid metabolism, hemostasis, blood plasma electrolytes, aminotransferases, echo-CG, bicycle exercise, rheoencephalography, ultrasonic dopplerography of head and neck vessels. Pumpan produced a positive effect total nonspecific systemic resistance improved, number of hospitalizations reduced, intracardiac hemodynamics improved in some cases with severe angina. Homeopathic compound pumpan can be recommended in the treatment of severe angina to reinforce antianginal effect, improve the disease clinical course, to obtain a hypocoagulative and hypocholesterolemic effect, to normalize intracardiac hemodynamics, to raise myocardial performance and intracoronary reserve as well as nonspecific resistance of the body.

  15. A Rare Case Report of Thoracic Ectopia Cordis: An Obstetrician’s Point of View in Multidisciplinary Approach

    Directory of Open Access Journals (Sweden)

    Diana Ramasauskaite

    2016-01-01

    Full Text Available Ectopia cordis is a rare congenital anomaly associated with the heart positioned outside of the thoracic cavity either partially or completely. It can be associated with other congenital abnormalities. Overall, the prognosis for infants with ectopia cordis is very poor but depends greatly on the type and severity of ectopia cordis and intracardiac and associated malformations. We present one case of a fetus with prenatally diagnosed thoracic ectopia cordis with intracardiac defects and omphalocele, all the abnormalities seen in pentalogy of Cantrell except a diaphragmatic defect. Considering poor prognosis for fetus, conservative management of prenatal care has been chosen. At the 42nd gestational week, during the active stage of labor, due to fetal distress, cesarean section was performed at a tertiary level hospital. The condition of the infant was impairing rapidly and the newborn succumbed within 24 hours. We discuss the perinatal care concerning this rare anomaly.

  16. Transesophageal echocardiography for cardiac thromboembolic risk assessment in patients with severe, symptomatic aortic valve stenosis referred for potential transcatheter aortic valve implantation.

    Science.gov (United States)

    Lenders, Guy D; Paelinck, Bernard P; Wouters, Kristien; Claeys, Marc J; Rodrigus, Inez E; Van Herck, Paul L; Vrints, Christiaan J; Bosmans, Johan M

    2013-05-15

    Stroke is a devastating complication after transcatheter aortic valve implantation (TAVI) and might partially be related to cardiac embolization. The aim of this single-center prospective study was to determine the incidence of intracardiac thrombi and left atrial spontaneous echo contrast (SEC), both known predictors of cardiac embolic stroke, in patients referred for potential TAVI. One hundred four consecutive patients with severe symptomatic aortic valve stenosis and at high or very high risk for surgery were included and underwent transesophageal echocardiography. In 11 patients (10.6%), intracardiac thrombi were detected, and 25 patients (24%) showed dense grade 2 SEC. Atrial fibrillation (p risk patients with severe aortic valve stenosis referred for potential TAVI is high and can accurately be detected using transesophageal echocardiography. Systematic thromboembolic evaluation using transesophageal echocardiography is thus recommended in patients referred for TAVI. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  18. Autotransplante cardíaco: um novo método no tratamento de problemas cardíacos complexos Heart autotransplantation: a new technique to complex intracardiac reppairs

    Directory of Open Access Journals (Sweden)

    Randas J. V Batista

    1995-06-01

    left atrium (4 cm (n=23; mitral stenosis (n=46; mitral insufficiency (n=28; mitral double lesion (n=16; aortic stenosis (n=12; aortic insufficiency (n=5; tricuspid insufficiency (n=75; atrial thrombosis (n=23; atrial calcification (n=12; pulmonnary hypertension (n=86; biventricular fibroelastose (n=3; atrioventricular rupture (n=1; aortic root aneurysm (n=1; partial ventriculectomy (n=8; 88 patients left the operating room and remained in sinus rhythm; 6 required inotropic drugs and 3 antiarrhythmic drugs. All patients with giant atria and atrial fibrillation had their atria reduced to normal sizes. There were no OR mortality and 6 patients died during hospitalization. Six months later the survivors were clinically well, in sinus rhythm. The technique of heart autotransplantation facilitates intracardiac reppairs, provides atrial reduction and returns patients with atrial fibrillation into sinus rhythm, and opens new frontiers.

  19. Assessment of the dynamics of atrial signals and local atrial period series during atrial fibrillation: effects of isoproterenol administration

    Directory of Open Access Journals (Sweden)

    Mantica Massimo

    2004-10-01

    Full Text Available Abstract Background The autonomic nervous system (ANS plays an important role in the genesis and maintenance of atrial fibrillation (AF, but quantification of its electrophysiologic effects is extremely complex and difficult. Aim of the study was to evaluate the capability of linear and non-linear indexes to capture the fine changing dynamics of atrial signals and local atrial period (LAP series during adrenergic activation induced by isoproterenol (a sympathomimetic drug infusion. Methods Nine patients with paroxysmal or persistent AF (aged 60 ± 6 underwent electrophysiological study in which isoproterenol was administered to patients. Atrial electrograms were acquired during i sinus rhythm (SR; ii sinus rhythm during isoproterenol (SRISO administration; iii atrial fibrillation (AF and iv atrial fibrillation during isoproterenol (AFISO administration. The level of organization between two electrograms was assessed by the synchronization index (S, whereas the degree of recurrence of a pattern in a signal was defined by the regularity index (R. In addition, the level of predictability (LP and regularity of LAP series were computed. Results LAP series analysis shows a reduction of both LP and R index during isoproterenol infusion in SR and AF (RSR = 0.75 ± 0.07 RSRISO = 0.69 ± 0.10, p AF = 0.31 ± 0.08 RAFISO = 0.26 ± 0.09, p SR = 99.99 ± 0.001 LPSRISO = 99.97 ± 0.03, p AF = 69.46 ± 21.55 LPAFISO = 55 ± 24.75; p SR = 0.49 ± 0.08 RSRISO = 0.46 ± 0.09 p AF = 0.29 ± 0.09 RAFISO = 0.28 ± 0.08 n.s.. Conclusions The proposed parameters succeeded in discriminating the subtle changes due to isoproterenol infusion during both the rhythms especially when considering LAP series analysis. The reduced value of analyzed parameters after isoproterenol administration could reflect an important pro-arrhythmic influence of adrenergic activation on favoring maintenance of AF.

  20. Case report

    African Journals Online (AJOL)

    Raoul

    2009-06-10

    Jun 10, 2009 ... Gokhan Yildirim et al [5] reported that EC is frequently associated with other congenital defects involving multiple organ systems. Ventricular septal defects and tetralogy of Fallot are the most common associated intracardiac defects, while omphalocele is the most common associated abdominal wall defect.

  1. Pentalogy of cantrell: A report of three cases | Sowande | Journal of ...

    African Journals Online (AJOL)

    Pentalogy of Cantrell is a rare upper midline syndrome that may present in association with anomalies outside the torso. The pentad - the supraumbilical body wall defect, sternal defect, deficiency of the anterior diaphragm, defect of the diaphragmatic pericardium, and the intracardiac anomalies - was first described by ...

  2. Applications of aerospace technology in biomedicine. A technology transfer profile: Patient monitoring

    Science.gov (United States)

    Murray, D. M.

    1971-01-01

    NASA contributions to cardiovascular monitoring are described along with innovations in intracardiac blood pressure monitoring. A brief overview of the process of NASA technology transfer in patient monitoring is presented and a list of bioinstrumentation tech briefs and the number of requests for technical support is included.

  3. Pericardiectomy as a diagnostic and therapeutic procedure.

    Science.gov (United States)

    Konik, Ewa; Geske, Jeffrey; Edwards, William; Gersh, Bernard

    2016-11-14

    A 70-year-old man presented with recent onset, predominantly right-sided heart failure. Echocardiogram demonstrated features of hypertensive heart disease and was suggestive of, but non-diagnostic for, constrictive pericarditis (CP). CT demonstrated mild pericardial thickening. Right heart catheterisation showed elevation and equalisation of diastolic pressures in all cardiac chambers with early rapid filling, minimal ventricular interdependence, and no dissociation of intrathoracic and intracardiac pressures. While several features pointed towards CP, the minimal ventricular interdependence and no dissociation of intrathoracic and intracardiac pressures suggested other pathology. Diagnostic pericardiectomy was performed, after which the central venous pressure decreased from 22 to 12 mm Hg. Pathology revealed pericardial fibrosis. The patient experienced sustained resolution of his heart failure. A potential explanation for lack of CP criteria was the presence of hypertensive heart disease. CP needs to be considered when approaching patients with heart failure as diagnostic evaluation can be multifaceted and treatment curative. 2016 BMJ Publishing Group Ltd.

  4. Cardiac magnetic resonance imaging in patients with congenital heart disease

    International Nuclear Information System (INIS)

    Kreitner, Karl-Friedrich; Sorantin, Erich

    2015-01-01

    The prevalence of congenital heart disease (CHD) is around 10 per 1000 live births in Germany. More than 90 % of these patients will survive into adulthood due to improvements in therapy. The classification of CHD may be based according to the anatomic structures involved, to the presence of an intracardiac shunt, the presence of a cyanosis and the intensity of therapy and complexity of the disease. Nearly half of all patients with CHD suffer from an intracardiac shunt, whereas complex cases such as patients with a tetralogy of Fallot or transposition of the great arteries are much more rare. Cardiac magnetic resonance imaging plays an important role in the work-up and follow-up of patients with CHD, especially after infancy and childhood. Depending on the abnormality in question, a multiparametric examination protocol is mandatory. Knowledge of operative procedures and findings of other imaging modalities help to optimize examination and time needed for it.

  5. Cardiac magnetic resonance imaging in patients with congenital heart disease; Kardiale MRT bei Patienten mit angeborenen Herzfehlern

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, Karl-Friedrich [Mainz Univ. Universitaetsmedizin Mainz (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kaufmann, Lilly [Mainz Univ. (Germany); Sorantin, Erich [Univ.-Klinik fuer Radiologie, Graz (Austria). Klinische Abt. fuer Kinderradiologie

    2015-06-15

    The prevalence of congenital heart disease (CHD) is around 10 per 1000 live births in Germany. More than 90 % of these patients will survive into adulthood due to improvements in therapy. The classification of CHD may be based according to the anatomic structures involved, to the presence of an intracardiac shunt, the presence of a cyanosis and the intensity of therapy and complexity of the disease. Nearly half of all patients with CHD suffer from an intracardiac shunt, whereas complex cases such as patients with a tetralogy of Fallot or transposition of the great arteries are much more rare. Cardiac magnetic resonance imaging plays an important role in the work-up and follow-up of patients with CHD, especially after infancy and childhood. Depending on the abnormality in question, a multiparametric examination protocol is mandatory. Knowledge of operative procedures and findings of other imaging modalities help to optimize examination and time needed for it.

  6. Patterns of anomalous pulmonary venous connection as seen at ...

    African Journals Online (AJOL)

    Supra-cardiac and intra-cardiac anomalous were the commonest type of TAPVC representing 43.6% and 35.9% respectively. Among all patients with TAPVC 51.35% were associated with ostium secundum atrial septal defect, 74.4% had moderate to severe pulmonary hypertension. Overall mortality was 9.25%. Mortality ...

  7. Uptake of dehydroascorbic acid and ascorbic acid to isolated nerve terminals and secretory granules from ox neurohypophyses

    DEFF Research Database (Denmark)

    Thorn, N A; Nielsen, F S; Jeppesen, C K

    1986-01-01

    When uptake of L-[14C]ascorbic acid ([14C]AA) to various organs in guinea-pigs was studied after intracardiac injection, the adenohypophysis, pars intermedia, and the neurohypophysis had an uptake per milligramme protein which was about half of the uptake to the adrenals. Adrenal uptake was 20...

  8. Evaluation Of A Haemostatic Agent In Rabbits | Turhan | African ...

    African Journals Online (AJOL)

    Animals were observed for 1 hr before euthanasia was performed by administering 40 mg of intracardiac suxamethonium chloride. In the event of death (cardiopulmonary arrest) before the end of the planned observation period of 60 minutes, time of death was recorded and histopathological examination of the liver and ...

  9. Author Details

    African Journals Online (AJOL)

    Sapsford, CW. Vol 13, No 1 (1978) - Articles Anatomical Evidence for Intracardiac Blood Shunting in Marine Turtles Abstract PDF · Vol 13, No 1 (1978) - Articles Body Temperature of the Loggerhead Sea Turtle Caretta Caretta and the Leatherback Sea Turtle Dermochelys Coriacea During Nesting Abstract PDF. ISSN: 2224- ...

  10. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  11. Value of postmortem computed tomography in comparison to autopsy

    International Nuclear Information System (INIS)

    Paperno, S.; Krug, B.; Lackner, L.; Riepert, T.; Rothschild, M.A.; Schultes, A.; Staak, M.

    2005-01-01

    Purpose: to assess the diagnostic value of postmortem computed tomography (CT) in comparison to autopsy. Materials and methods: twenty-seven cadavers were examined by sequential cranial CT and helical CT through the neck, thorax and abdomen and subsequently underwent an autopsy with histomorphologic examination of the pathologic specimens. The findings of CT, autopsy and histology were registered and compared by three radiologists and one specialist for forensic medicine, using a data entry form. Results: in 19 of 27 cases, the findings explaining the cause of death were concordant for CT and autopsy. Intracranial, intraspinal and intracardiac gas accumulations (n = 12) were registered by CT alone. The detection of skull fractures was equal for both methods (n = 3). CT showed diagnostic problems in the assessment of pneumonic infiltrations (n = 16) and pulmonary edema (n = 21). Conclusion: CT is a useful and complementary method to autopsy. (orig.)

  12. [Pressure sensors to prevent cardiac decompensation].

    Science.gov (United States)

    Klug, Didier

    2017-11-01

    Most cases of hospitalisation for heart failure are preceded by episodes of cardiac decompensation. Preventing these episodes would improve quality of life and reduce mortality and treatment costs. The monitoring of intracardiac pressures, using innovative sensors, coupled with telemedicine, offers interesting perspectives. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  14. ADRENAL HORMONES IN RATS BEFORE AND AFTER STRESS-EXPERIENCE - EFFECTS OF IPSAPIRONE

    NARCIS (Netherlands)

    KORTE, SM; BOUWS, GAH; BOHUS, B

    The present study was designed to investigate the effects of the anxiolytic 5-HT1A receptor agonist ipsapirone on the hormonal responses in rats under nonstress and stress conditions by means of repeated blood sampling through an intracardiac catheter. Ipsapirone was given in doses of 2.5, 5, 10.

  15. Medical First-Trimester Termination of Pregnancy with Massive Fibroid Uterus

    Directory of Open Access Journals (Sweden)

    Michael Saad-Naguib

    2017-01-01

    Full Text Available First-trimester termination of pregnancy by medical or surgical route is highly effective with a low complication rate. Uterine abnormalities can complicate a procedure due to distortion of normal anatomy. In this case presentation, medical termination of pregnancy is performed using fetal intracardiac potassium chloride injection and intramuscular methotrexate.

  16. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  17. Potential fields on the ventricular surface of the exposed dog heart during normal excitation.

    Science.gov (United States)

    Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S; Taccardi, B

    1983-06-01

    We studied the normal spread of excitation on the anterior and posterior ventricular surface of open-chest dogs by recording unipolar electrograms from an array of 1124 electrodes spaced 2 mm apart. The array had the shape of the ventricular surface of the heart. The electrograms were processed by a computer and displayed as epicardial equipotential maps at 1-msec intervals. Isochrone maps also were drawn. Several new features of epicardial potential fields were identified: (1) a high number of breakthrough points; (2) the topography, apparent widths, velocities of the wavefronts and the related potential drop; (3) the topography of positive potential peaks in relation to the wavefronts. Fifteen to 24 breakthrough points were located on the anterior, and 10 to 13 on the posterior ventricular surface. Some were in previously described locations and many others in new locations. Specifically, 3 to 5 breakthrough points appeared close to the atrioventricular groove on the anterior right ventricle and 2 to 4 on the posterior heart aspect; these basal breakthrough points appeared when a large portion of ventricular surface was still unexcited. Due to the presence of numerous breakthrough points on the anterior and posterior aspect of the heart which had not previously been described, the spread of excitation on the ventricular surface was "mosaic-like," with activation wavefronts spreading in all directions, rather than radially from the two breakthrough points, as traditionally described. The positive potential peaks which lay ahead of the expanding wavefronts moved along preferential directions which were probably related to the myocardial fiber direction.

  18. In situ cardiac perfusion reveals interspecific variation of intraventricular flow separation in reptiles.

    Science.gov (United States)

    Joyce, William; Axelsson, Michael; Altimiras, Jordi; Wang, Tobias

    2016-07-15

    The ventricles of non-crocodilian reptiles are incompletely divided and provide an opportunity for mixing of oxygen-poor blood and oxygen-rich blood (intracardiac shunting). However, both cardiac morphology and in vivo shunting patterns exhibit considerable interspecific variation within reptiles. In the present study, we develop an in situ double-perfused heart approach to characterise the propensity and capacity for shunting in five reptile species: the turtle Trachemys scripta, the rock python Python sebae, the yellow anaconda Eunectes notaeus, the varanid lizard Varanus exanthematicus and the bearded dragon Pogona vitticeps To simulate changes in vascular bed resistance, pulmonary and systemic afterloads were independently manipulated and changes in blood flow distribution amongst the central outflow tracts were monitored. As previously demonstrated in Burmese pythons, rock pythons and varanid lizards exhibited pronounced intraventricular flow separation. As pulmonary or systemic afterload was raised, flow in the respective circulation decreased. However, flow in the other circulation, where afterload was constant, remained stable. This correlates with the convergent evolution of intraventricular pressure separation and the large intraventricular muscular ridge, which compartmentalises the ventricle, in these species. Conversely, in the three other species, the pulmonary and systemic flows were strongly mutually dependent, such that the decrease in pulmonary flow in response to elevated pulmonary afterload resulted in redistribution of perfusate to the systemic circuit (and vice versa). Thus, in these species, the muscular ridge appeared labile and blood could readily transverse the intraventricular cava. We conclude that relatively minor structural differences between non-crocodilian reptiles result in the fundamental changes in cardiac function. Further, our study emphasises that functionally similar intracardiac flow separation evolved independently in

  19. A case of multiple cardiac calcified amorphous tumours

    Directory of Open Access Journals (Sweden)

    Amrit Chowdhary

    2017-05-01

    Full Text Available Cardiac calcified amorphous tumours of the heart are rare non-neoplastic cardiac masses that can present like a malignant mass or an intra-cardiac thrombus. We report an extremely unusual case of a 73 year old man who presented to hospital with dyspnoea and subsequent investigations revealed multiple cardiac CATs.

  20. Morphofunctional state of the heart in children and adolescents who suffered due to Chernobyl accident (findings of ultrasound studies)

    International Nuclear Information System (INIS)

    Kostenko, T.O.

    1998-01-01

    Great incidence of intracardiac hemodynamic disorders in children and adolescents evacuated from the contaminated zone (mainly in those who resided in Zhytomir region for a long period) testifies to the possible negative effect of ionizing radiation on cardiovascular system. A rehabilitation treatment scheme for such children and adolescents should include cardiotonic and vegetotropic remedies

  1. Thrombus Development on a Transseptal Sheath in the Right Atrium Before Electrical Pulmonary Vein Isolation

    Directory of Open Access Journals (Sweden)

    Nieves Romero-Rodriguez

    2008-02-01

    Full Text Available We describe the case of a patient who developed a thrombus on the transseptal sheath in the right atrium before transseptal puncture for circumferential pulmonary vein isolation for paroxysmal atrial fibrillation treatment. The use of intracardiac echocardiography allowed to its identification and probably prevented the patient from suffering a serious thromboembolic complication.

  2. Synergistic nonuniform shortening of atrial refractory period induced by autonomic stimulation.

    Science.gov (United States)

    Takei, M; Furukawa, Y; Narita, M; Ren, L M; Karasawa, Y; Murakami, M; Chiba, S

    1991-12-01

    We investigated the nonuniform effects of autonomic nerve stimulation of the effective refractory period (ERP) of the right atrium in the anesthetized dog. Stimulation of the discrete intracardiac sympathetic nerves to the sinoatrial (SA) nodal region uniformly shortened ERPs at three sites in the right atrium after administration of atropine. Right ansa subclavia (RS) stimulation similarly shortened ERPs in the absence of atropine. Stimulation of the discrete intracardiac parasympathetic nerves to the SA nodal region (SAP stimulation) shortened ERPs of the right atrium in a nonuniform manner. Simultaneous RS and SAP stimulation additively shortened ERPs at each site and decreased sinus rate much more than SAP stimulation alone. Shortening of ERP induced by SAP stimulation was greater than that induced by RS stimulation at similar absolute changes in heart rate. These results suggest that simultaneous activation of sympathetic and parasympathetic nerves nonuniformly shortens the ERP in the right atrium as the algebraic sum of the individual responses to each stimulation. However, parasympathetics exert the principal neural control over atrial ERP.

  3. The role of stents in the treatment of congenital heart disease: Current status and future perspectives

    International Nuclear Information System (INIS)

    Peters, Bjoern; Ewert, Peter; Berger, Felix

    2009-01-01

    Intravascular or intracardiac stenoses occur in many forms of congenital heart disease (CHD). Therefore, the implantation of stents has become an accepted interventional procedure for stenotic lesions in pediatric cardiology. Furthermore, stents are know to be used to exclude vessel aneurysm or to ensure patency of existing or newly created intracardiac communications. With the further refinement of the first generation of devices, a variety of “modern” stents with different design characteristics have evolved. Despite the tremendous technical improvement over the last 20 years, the “ideal stent” has not yet been developed. Therefore, the pediatric interventionalist has to decide which stent is suitable for each lesion. On this basis, currently available stents are discussed in regard to their advantages and disadvantages for common application in CHD. New concepts and designs developed to overcome some of the existing problems, like the failure of adaptation to somatic growth, are presented. Thus, in the future, biodegradable or growth stents might replace the currently used generation of stents. This might truly lead to widening indications for the use of stents in the treatment of CHD

  4. Electrocardiographic intricacies clarified by echocardiography--should the electrocardiogram be interpreted echocardiographically?

    Science.gov (United States)

    Ker, James

    2012-07-12

    During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Long-term survival of quiescent left atrial myxoma in an elderly patient.

    Science.gov (United States)

    Kay, Jay F L; Chow, Wing Hing

    2002-01-01

    Left atrial myxoma, if left untreated, is inexorably progressive and usually fatal. The classical management of this disease is prompt surgical removal. However, there may be exceptions to this traditional dogma. The authors report an 85-year-old man who presented with features of chronic obstructive airway disease and congestive heart failure 15 years previously. Auscultation of the heart showed a pansystolic murmur. Two-dimensional echocardiography revealed a nonobstructive, calcified, and well circumscribed mass in the left atrium, with a pedicle attached to the interatrial septum. Because the patient refused high-risk cardiac surgery related to his comorbidity, he was managed medically with a bronchodilator, diuretics, and digoxin. There have been no features of embolism or intracardiac obstruction, and serial echocardiography demonstrates no disease progression over this long period of time. This case illustrates that calcified left atrial myxoma may exhibit a quiescent phase. Tumor calcification, slow growth potential, and the absence of intracardiac obstruction may correlate with a better outcome in the elderly patient. (c)2002 CVRR, Inc.

  6. Robotic cardiac surgery: an anaesthetic challenge.

    Science.gov (United States)

    Wang, Gang; Gao, Changqing

    2014-08-01

    Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Successful Radiofrequency Catheter Ablation for Wolff-Parkinson-White Syndrome Within the Neck of a Coronary Sinus Diverticulum

    Science.gov (United States)

    Jang, Sung-Won; Kim, Dong-Bin; Kwon, Bum-Jun; Cho, Eun-Joo; Shin, Woo-Seung; Kim, Ji-Hoon; Jin, Seung-Won; Oh, Yong-Seog; Lee, Man-Young; Kim, Jae-Hyung

    2009-01-01

    Posteroseptal accessory pathways are often associated with coronary sinus diverticula. These diverticula contain myocardial coats which serve as a bypass tract. We report a 54-year-old woman who underwent radiofrequency (RF) catheter ablation for Wolff-Parkinson-White (WPW) syndrome. The surface electrocardiography (ECG) demonstrated pre-excitation, indicating a posteroseptal accessory pathway. A catheter ablation via a transaortic approach failed to ablate the accessory pathway. Coronary sinus venography revealed the presence of a diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the coronary sinus myocardial extension potential, which was successfully ablated by delivery of RF energy. PMID:19949625

  8. Inappropriate mode switching clarified by using a chest radiograph

    Directory of Open Access Journals (Sweden)

    Brian Marino, DO

    2015-08-01

    Full Text Available An 80-year-old woman with a history of paroxysmal atrial fibrillation and atrioventricular node disease status post-dual chamber pacemaker placement was noted to have abnormal pacing episodes during a percutaneous coronary intervention. Pacemaker interrogation revealed a high number of short duration mode switching episodes. Representative electrograms demonstrated high frequency nonphysiologic recordings predominantly in the atrial lead. Intrinsic pacemaker malfunction was excluded. A chest radiograph showed excess atrial and ventricular lead slack in the right ventricular inflow. It was suspected that lead–lead interaction resulted in artifacts and oversensing, causing frequent short episodes of inappropriate mode switching.

  9. Clinical evaluation of the platelet scintigraphy using indium-111 oxine

    International Nuclear Information System (INIS)

    Ishikawa, Nobuyoshi; Takeda, Tohoru; Nakajima, Kohtaroh; Satoh, Motohiro; Akisada, Masayoshi; Ijima, Hiroshi

    1988-01-01

    The clinical usefulness of autologous platelets labeled with Indium-111 oxine was evaluated by scintigraphy as a diagnostic procedure for the detection of various thrombotic disorders as well as in different aneurysms. The positivity was found to be satisfactory (80.0 %) in cases of aortic aneurysm while thoracic aneurysm showed comparatively poor accumulation. High positivity was also demonstrated in deep vein thrombosis. The complimentary role of this method for intracardiac thrombi to echocardiography was noted. The labeling procedure of indium-111 oxine was fairly easy to perform and the activity of labeled platelets was sustained enough to yield good results. In one case scintigraphy was performed successfully after 19 hours of angiography when a hot area of labeled platelets was seen at the puncture site. This method was therefore varified to be a sensitive and reliable method in the assessment of thrombus activity, and as it demonstrates the activity, its helpfulness in the conservative treatment of these disorders is warranted. (author)

  10. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  11. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  12. HYPOMAGNESAEMIA AND ROLE OF MAGNESIUM SUPPLEMENTATION DURING CARDIOPULMONARY BYPASS IN PEDIATRICS CARDIAC SURGERY

    Directory of Open Access Journals (Sweden)

    Vivek

    2016-01-01

    Full Text Available BACKGROUND Postoperative Junctional Ectopic Tachycardia (JET remains one of the most common arrhythmias (8%-20% after paediatric cardiac surgery. JET is associated with hemodynamic instability, longer mechanical ventilation time and longer stays in the Cardiac Intensive Care Unit (ICU. AIM The aim of this study is to evaluate the effect of prophylactic administration of magnesium on the occurrence of postoperative arrhythmias in patients undergoing intracardiac repair for Tetralogy of Fallot and to determine the incidence of hypomagnesaemia in paediatric patients undergoing cardiac surgery who require CPB. METHODS Forty five patients with Tetralogy of Fallot undergoing intracardiac repair were enrolled to receive saline, 25mg/kg and 50mg/kg of Magnesium as three groups intraoperatively. Postoperative ECG monitored for JET and magnesium levels measured. RESULTS Hypomagnesaemia was present in 28% of patients. None of the patients who were administered magnesium developed hypomagnesaemia. The incidence of JET was found to be increased (53.3% in the placebo group as compared to 13.3% and 6.7% in the groups receiving 25 and 50mg/kg of magnesium (p<0.001. Eleven patients having JET 7 (64% had hypomagnesaemia and rest of the 4(36% occurred in patients with normal magnesium levels (p<0.01. The mean mechanical ventilation time and the mean length of ICU stay were both prolonged those with hypomagnesaemia. The mean mechanical ventilation time and length of ICU stay were both prolonged in the patients with JET (p<.001 CONCLUSIONS Hypomagnesemia is one of the factors responsible for JET and in turn with prolonged ICU stay and prolonged mechanical ventilation.

  13. Intracardiac air- the "hospital killer' identified? | Smith | South African ...

    African Journals Online (AJOL)

    Venous access is an essential part of caring for the sick neonate. The primary problem with catheters, whether peripherally or centrally placed, is the difficulty in maintaining them, the development of phlebitis and systemic infection, and fluid extravasation. A lesser known complication is the development of venous air ...

  14. Periodontal disease is an independent predictor of intracardiac calcification.

    Science.gov (United States)

    Pressman, Gregg S; Qasim, Atif; Verma, Nitin; Miyamae, Masami; Arishiro, Kumiko; Notohara, Yasuhiro; Crudu, Vitalie; Figueredo, Vincent M

    2013-01-01

    Periodontitis is the most common chronic inflammatory condition worldwide and is associated with incident coronary disease. We hypothesized that periodontal disease would also be associated with cardiac calcification, a condition which shares many risk factors with atherosclerosis and is considered a marker of subclinical atherosclerosis. Cross-sectional study at two sites (USA and Japan) involving subjects with both clinical echocardiograms and detailed dental examinations. Semiquantitative scoring systems were used to assess severity of periodontal disease and echocardiographic calcification. Fifty-six of 73 subjects (77%) had cardiac calcifications, and 51% had moderate to severe periodontal disease (score > 2). In unadjusted analysis, a significant relationship between periodontal score and cardiac calcification (Spearman rho = 0.4, P = 0.001) was noted, with increases in mean calcification score seen across increasing levels of periodontal disease. On multivariate logistic regression, adjusted for age, gender, race, glomerular filtration rate, and traditional risk factors, this association remained significant (P = 0.024). There was no significant interaction by study site, race, or gender. In a multiracial population, we found a significant association between the degree of periodontal disease, a chronic inflammatory condition, and cardiac calcification. Further, higher periodontal scores were associated with greater degrees of calcification.

  15. In vivo detection of apoptosis in an intracardiac tumor

    NARCIS (Netherlands)

    Hofstra, L; Dumont, E A; Thimister, P W; Heidendal, G A; DeBruine, A P; Elenbaas, T W; Boersma, H H; van Heerde, W L; Reutelingsperger, C P

    2001-01-01

    We previously demonstrated in vivo imaging of cell death in the myocardia of patients with acute myocardial infarction using technetium Tc 99m–labeled annexin-V (99mTc-p-annexin-V [Apomate], Theseus Imaging, Cambridge, Mass) and nuclear imaging.1 Because high proliferation and apoptotic indices have

  16. Intracardiac flow patterns studied by cine MR flow imaging

    International Nuclear Information System (INIS)

    Underwood, S.R.; Firmin, D.N.; Klipstein, R.H.; Rees, R.S.O.; Longmore, D.B.

    1986-01-01

    Velocity mapping by means of cine-MR imaging allows accurate measurement of velocity and flow within the cardiovascular system. A cine display and color coding simplify interpretation. The author have used the technique in a variety of patients to illustrate its potential. Velocity mapping in coronary artery by pass grafts in six patients provided a measure of graft function. Coronary artery velocities were measured in three subjects. Flow was measured through defects in the atrial septum, the ventricular septum, and a Gerbode defect. Velocity was reduced distal to coarctation of the aorta and was increased at the level of a partial venous occlusion by thrombosis. In a patient with isomerism, velocity mapping in the central vessels aided interpretation. Cine-MR imaging velocity mapping combined with conventional imaging yields important functional information on the cardiovascular system

  17. Volumetric Real-Time Imaging Using a CMUT Ring Array

    OpenAIRE

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N.; O’Donnell, Matthew; Sahn, David J.; Khuri-Yakub, Butrus T.

    2012-01-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device.

  18. The role of local voltage potentials in outflow tract ectopy

    DEFF Research Database (Denmark)

    Thomsen, P.E.B.; Johannessen, A.; Jons, C.

    2010-01-01

    in the ventricular premature beats. In 10 patients, ventricular parasystole was suggested by varying coupling intervals > 100 ms, and fusion beats allowing for the estimation of the least common denominator of R-R intervals. In 23 of the 25 patients, the 12-lead electrocardiogram (ECG) and intracardiac contact...... of depressed conductivity known to be a prerequisite for experimental ventricular ectopy including parasystole....

  19. 4D ultrasound and 3D MRI registration of beating heart

    International Nuclear Information System (INIS)

    Herlambang, N.; Matsumiya, K.; Masamune, K.; Dohi, T.; Liao, H.; Tsukihara, H.; Takamoto, S.

    2007-01-01

    To realize intra-cardiac surgery without cardio-pulmonary bypass, a medical imaging technique with both high image quality and data acquisition rate that is fast enough to follow heart beat movements is required. In this research, we proposed a method that utilized the image quality of MRI and the speed of ultrasound. We developed a 4D image reconstruction method using image registration of 3D MRI and 4D ultrasound images. The registration method consists of rigid registration between 3D MRI and 3D ultrasound with the same heart beat phase, and non-rigid registration between 3D ultrasound images from different heart beat phases. Non-rigid registration was performed with B-spline based registration using variable spring model. In phantom experiment using balloon phantom, registration accuracy was less than 2 mm for total heart volume variation range of 10%. We applied our registration method on 3D MRI and 4D ultrasound images of a volunteer's beating heart data and confirmed through visual observation that heart beat pattern was well reproduced. (orig.)

  20. The effect of activation rate on left atrial bipolar voltage in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Williams, Steven E; Linton, Nick; O'Neill, Louisa; Harrison, James; Whitaker, John; Mukherjee, Rahul; Rinaldi, Christopher A; Gill, Jaswinder; Niederer, Steven; Wright, Matthew; O'Neill, Mark

    2017-09-01

    Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4-4-4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak-to-peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P voltage attenuation (P = 0.026). Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate. © 2017 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  1. A Prospective Study of Ripple Mapping the Post-Infarct Ventricular Scar to Guide Substrate Ablation for Ventricular Tachycardia.

    Science.gov (United States)

    Luther, Vishal; Linton, Nick W F; Jamil-Copley, Shahnaz; Koa-Wing, Michael; Lim, Phang Boon; Qureshi, Norman; Ng, Fu Siong; Hayat, Sajad; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa

    2016-06-01

    Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation. © 2016 American Heart Association, Inc.

  2. Characterization of respiratory and cardiac motion from electro-anatomical mapping data for improved fusion of MRI to left ventricular electrograms.

    Directory of Open Access Journals (Sweden)

    Sébastien Roujol

    Full Text Available Accurate fusion of late gadolinium enhancement magnetic resonance imaging (MRI and electro-anatomical voltage mapping (EAM is required to evaluate the potential of MRI to identify the substrate of ventricular tachycardia. However, both datasets are not acquired at the same cardiac phase and EAM data is corrupted with respiratory motion limiting the accuracy of current rigid fusion techniques. Knowledge of cardiac and respiratory motion during EAM is thus required to enhance the fusion process. In this study, we propose a novel approach to characterize both cardiac and respiratory motion from EAM data using the temporal evolution of the 3D catheter location recorded from clinical EAM systems. Cardiac and respiratory motion components are extracted from the recorded catheter location using multi-band filters. Filters are calibrated for each EAM point using estimates of heart rate and respiratory rate. The method was first evaluated in numerical simulations using 3D models of cardiac and respiratory motions of the heart generated from real time MRI data acquired in 5 healthy subjects. An accuracy of 0.6-0.7 mm was found for both cardiac and respiratory motion estimates in numerical simulations. Cardiac and respiratory motions were then characterized in 27 patients who underwent LV mapping for treatment of ventricular tachycardia. Mean maximum amplitude of cardiac and respiratory motion was 10.2±2.7 mm (min = 5.5, max = 16.9 and 8.8±2.3 mm (min = 4.3, max = 14.8, respectively. 3D Cardiac and respiratory motions could be estimated from the recorded catheter location and the method does not rely on additional imaging modality such as X-ray fluoroscopy and can be used in conventional electrophysiology laboratory setting.

  3. Radionuclide angiocardiography in the diagnosis of congenital heart disorders

    International Nuclear Information System (INIS)

    Jones, R.H.; Austin, E.H.; Peter, C.A.; Sabiston, D.C. Jr.

    1981-01-01

    Radionuclide angiocardiography provides a noninvasive assessment of cardiac function and blood flow through the heart and lungs. During the past three years, this procedure has been used at the Duke University Medical Center for evaluation of 343 patients with congenital heart disorders. A review of this experience shows tat the resulting data were frequently useful in the surgical management of these patients. In patients with abnormal blood flow patterns, noninvasive imaging of blood flow was useful before and after operative correction. Radionuclide measurements of left-to-right intracardiac shunts were sufficiently accurate for use in the initial evaluation of patients with murmurs and to document the absence of shunt after operative closure of intracardiac septal defects. Moreover, measurements of right-to-left cardiac shunts were of benefit in the management of children with cyanotic heart disease. Measurements of left ventricular function obtained during rest and exercise were most useful in patients with origin of the left coronary artery from the pulmonary artery and in patients with congenital valvular insufficiency. This experience demonstrates that radionuclide angiocardiography provides important measurements of central hemodynamics and cardiac function which are useful in the management of patients with congenital heart disorders

  4. Pentalogy of Cantrell: Complete expression with mediastinal teratoma

    Directory of Open Access Journals (Sweden)

    Michał Błaszczyński

    2015-08-01

    Full Text Available Pentalogy of Cantrell (POC is a rare, and often fatal congenital disorder that is characterized by a pentad consisting of ectopia cordis, omphalocele, sternal cleft, congenital diaphragmatic hernia, and various intra-cardiac defects. Although the hallmark of POC consists of these five anomalies, only a handful of cases have been reported with the full spectrum of this disorder. This case report presents a full term female with complete expression of POC and a mediastinal teratoma. Two days after birth, this infant underwent correction of the omphalocele and diaphragmatic defect, with repositioning of the cardiac apex within the thoracic cavity. Three months later surgical correction of the intra-cardiac defects took place. At initiation of cardiac by-pass a mediastinal mass at the superior cavopulmonary junction was identified and excised. This mass on histopathology was a teratoma, which makes this case unique as the occurrence of POC and mediastinal teratoma is unreported. This infant has survived the series of corrective surgeries, and is now functioning well. Conclusion: when POC is suspected further investigation for associated anomalies is required for a planned multidisciplinary surgical approach combined with neonatal intensive care to afford the opportunity for a successful outcome.

  5. Pentalogía de Cantrell (ectopia cordis: reporte de un caso Pentalogy of Cantrell (ectopia cordis: report of one case

    Directory of Open Access Journals (Sweden)

    Carlos E Riaño

    2010-12-01

    Full Text Available La pentalogía de Cantrell involucra defectos de la línea media abdominal supraumbilical, parte inferior del esternón, diafragma anterior, pericardio diafragmático y malformaciones congénitas intracardiacas (1, 2. Su pronóstico está supeditado al diagnóstico temprano, la severidad de la malformación cardiaca y las anomalías asociadas (3. Se reporta el caso de una gestante de 28 semanas con diagnóstico fetal de pentalogía de Cantrell: ectopia cordis verdadera toraco-abdominal (con anomalía intracardiaca y fisura esternal, y se resalta el diagnóstico prenatal que permitió definir su pronóstico y planear el manejo.Pentalogy of Cantrell involves defects of the midlline supraumbilical abdomen, lower sternum, anterior diaphragm, diaphragmatic pericardium and intracardiac congenital defects. Prognosis depends on early diagnosis, severity of cardiac malformation and associated anomalies. We report the case of a 28 weeks pregnant woman with fetal diagnosis of pentalogy of Cantrell: true thoraco-abdominal ectopia cordis (with intracardiac anomaly and sternal cleft, and highlight prenatal diagnosis that allowed to define prognosis and plan management.

  6. TROMBO GIGANTE DE AURÍCULA DERECHA COMO CAUSA DE ANGINA Y SÍNCOPE / Giant thrombus in right atrium as a cause of angina and syncope

    Directory of Open Access Journals (Sweden)

    José L. Aparicio Suárez

    2012-07-01

    Full Text Available ResumenLas tumoraciones intracardíacas son poco frecuentes, y pueden ser de tipo neoplásicas y no neoplásicas. De estas últimas, los trombos, constituyen las masas más frecuentes. Se presenta un paciente joven, operado en el Cardiocentro "Ernesto Che Guevara" de Villa Clara, Cuba, con antecedentes de trastornos hematológicos desde la infancia, que comienza con episodios de disnea progresiva, angina y síncope; con diagnóstico preoperatorio de tumoración gigante en aurícula derecha que resultó ser un trombo intracardíaco, y se demostró la presencia de un agujero oval permeable. / AbstractIntracardiac tumors are rare, and may be of neoplastic and non-neoplastic types. In the latter, the thrombi are the most frequent masses. This is the case of a young patient operated at the Cardiocentro "Ernesto Che Guevara" of Villa Clara, Cuba, with a history of blood disorders since childhood, starting with episodes of progressive dyspnea, angina and syncope, with pre-operative diagnosis of giant tumor in right atrium which turned out to be an intracardiac thrombus, and the presence of a patent foramen ovale was shown.

  7. Diagnostic value of imaging in infective endocarditis: a systematic review.

    Science.gov (United States)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    2017-01-01

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  9. Correlation of Ventricular Arrhythmogenesis with Neuronal Remodeling of Cardiac Postganglionic Parasympathetic Neurons in the Late Stage of Heart Failure after Myocardial Infarction.

    Science.gov (United States)

    Zhang, Dongze; Tu, Huiyin; Wang, Chaojun; Cao, Liang; Muelleman, Robert L; Wadman, Michael C; Li, Yu-Long

    2017-01-01

    Introduction: Ventricular arrhythmia is a major cause of sudden cardiac death in patients with chronic heart failure (CHF). Our recent study demonstrates that N-type Ca 2+ currents in intracardiac ganglionic neurons are reduced in the late stage of CHF rats. Rat intracardiac ganglia are divided into the atrioventricular ganglion (AVG) and sinoatrial ganglion. Only AVG nerve terminals innervate the ventricular myocardium. In this study, we tested the correlation of electrical remodeling in AVG neurons with ventricular arrhythmogenesis in CHF rats. Methods and Results: CHF was induced in male Sprague-Dawley rats by surgical ligation of the left coronary artery. The data from 24-h continuous radiotelemetry ECG recording in conscious rats showed that ventricular tachycardia/fibrillation (VT/VF) occurred in 3 and 14-week CHF rats but not 8-week CHF rats. Additionally, as an index for vagal control of ventricular function, changes of left ventricular systolic pressure (LVSP) and the maximum rate of left ventricular pressure rise (LV dP/dt max ) in response to vagal efferent nerve stimulation were blunted in 14-week CHF rats but not 3 or 8-week CHF rats. Results from whole-cell patch clamp recording demonstrated that N-type Ca 2+ currents in AVG neurons began to decrease in 8-week CHF rats, and that there was also a significant decrease in 14-week CHF rats. Correlation analysis revealed that N-type Ca 2+ currents in AVG neurons negatively correlated with the cumulative duration of VT/VF in 14-week CHF rats, whereas there was no correlation between N-type Ca 2+ currents in AVG neurons and the cumulative duration of VT/VF in 3-week CHF. Conclusion: Malignant ventricular arrhythmias mainly occur in the early and late stages of CHF. Electrical remodeling of AVG neurons highly correlates with the occurrence of ventricular arrhythmias in the late stage of CHF.

  10. Gated blood pool imaging in the diagnosis and management of arrhythmia

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Kawai, Naoki; Okada, Mitsuhiro; Matsushima, Hideo; Kato, Rinya; Sotobata, Iwao; Tanahashi, Yoshibumi.

    1985-01-01

    The usefulness of multigated cardiac blood pool imaging in evaluating left ventricular function and ventricular activation was studied in patients with cardiac arrhythmias. Subjects consisted of 12 patients with the Wolff-Parkinson-White (WPW) syndrome; 20 with ventricular premature contractions (VPC); 21 with various modes of artificial pacemakers; and two normal controls. 1. Phase analysis was useful in localizing the bypass tract in patients with the WPW syndrome. In four patients with the WPW syndrome and five with VVI pacing, the phase difference between the posterolateral wall of the left ventricle (LV) and the right ventricular apex correlated significantly with the activation time difference between these two regions as assessed by endocardial electrograms (r = 0.94, p < 0.001). 2. Images of VPC were obtained using the bad beat rejection program in an ADAC computer system. The origin of VPCs evaluated by phase image coincided with results of standard 12-lead electrograms. 3. The LV ejection fraction (LVEF) decreased significantly (p < 0.001) after the injection of lidocaine (-3.7 %) or disopyramide (-6.2 %). The percent reduction in LVEF was significantly greater with disopyramide than with lidocaine (-15.1 vs -11.2 %). There was a significant correlation between the percent reduction in LVEF and the disopyramide plasma concentrations (r = -0.62, p < 0.001). 4. The influence of the pacing mode and exercise on LV function was studied in 21 patients with artificial pacemakers. In the VDD and DDD modes, end-diastolic volume (EDV) and cardiac output (CO) decreased after converting to VVI mode. CO increased markedly to approximately 250 % of the control value in the VDD and DDD, and moderately in the VVI and AAI modes during ergometer exercise. (J.P.N.)

  11. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, J.M.; Nyo, H.; Vera, Z.; Seibert, J.A.; Vogelsang, P.J. (Division of Cardiovascular Medicine, University of California, School of Medicine, Davis (USA))

    1991-04-01

    Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm{sup 2}). In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 {plus minus} 3 (mean {plus minus} SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 {plus minus} 4 msec and -35 {plus minus} 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs.

  12. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack.

    Science.gov (United States)

    Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak; Moeinipour, Aliasghar

    2017-01-01

    Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.

  13. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi Teshnizi

    2017-01-01

    Full Text Available Cardiac calcified amorphous tumors (CATs are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.

  14. From 4D medical images (CT, MRI, and Ultrasound) to 4D structured mesh models of the left ventricular endocardium for patient-specific simulations

    OpenAIRE

    Canè, Federico; Verhegghe, Benedict; De Beule, Matthieu; Bertrand, Philippe B.; Van der Geest, Rob J.; Segers, Patrick; De Santis, Gianluca

    2018-01-01

    With cardiovascular disease (CVD) remaining the primary cause of death worldwide, early detection of CVDs becomes essential. The intracardiac flow is an important component of ventricular function, motion kinetics, wash-out of ventricular chambers, and ventricular energetics. Coupling between Computational Fluid Dynamics (CFD) simulations and medical images can play a fundamental role in terms of patient-specific diagnostic tools. From a technical perspective, CFD simulations with moving boun...

  15. MR-based real time path planning for cardiac operations with transapical access.

    Science.gov (United States)

    Yeniaras, Erol; Navkar, Nikhil V; Sonmez, Ahmet E; Shah, Dipan J; Deng, Zhigang; Tsekos, Nikolaos V

    2011-01-01

    Minimally invasive surgeries (MIS) have been perpetually evolving due to their potential high impact on improving patient management and overall cost effectiveness. Currently, MIS are further strengthened by the incorporation of magnetic resonance imaging (MRI) for amended visualization and high precision. Motivated by the fact that real-time MRI is emerging as a feasible modality especially for guiding interventions and surgeries in the beating heart; in this paper we introduce a real-time path planning algorithm for intracardiac procedures. Our approach creates a volumetric safety zone inside a beating heart and updates it on-the-fly using real-time MRI during the deployment of a robotic device. In order to prove the concept and assess the feasibility of the introduced method, a realistic operational scenario of transapical aortic valve replacement in a beating heart is chosen as the virtual case study.

  16. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  17. Age-related location of manifest accessory pathway and clinical consequences.

    Science.gov (United States)

    Brembilla-Perrot, Béatrice; Huttin, Olivier; Olivier, Arnaud; Sellal, Jean Marc; Villemin, Thibaut; Manenti, Vladimir; Moulin-Zinsch, Anne; Marçon, François; Simon, Gauthier; Andronache, Marius; Beurrier, Daniel; de Chillou, Christian; Girerd, Nicolas

    2015-01-01

    Accessory pathway (AP) ablation is not always easy. Our purpose was to assess the age-related prevalence of AP location, electrophysiological and prognostic data according to this location. Electrophysiologic study (EPS) was performed in 994 patients for a pre-excitation syndrome. AP location was determined on a 12 lead ECG during atrial pacing at maximal preexcitation and confirmed at intracardiac EPS in 494 patients. AP location was classified as anteroseptal (AS)(96), right lateral (RL)(54), posteroseptal (PS)(459), left lateral (LL)(363), nodoventricular (NV)(22). Patients with ASAP or RLAP were younger than patients with another AP location. Poorly-tolerated arrhythmias were more frequent in patients with LLAP than in other patients (0.009 for ASAP, 0.0037 for RLAP, location was confirmed at intracardiac EPS. Among untreated patients, poorly-tolerated arrhythmia occurred in patients with LLAP (3) or PSAP (6). Failures of ablation were more frequent for AS or RL AP than for LL or PS AP. AS and RLAP location in pre-excitation syndrome was more frequent in young patients. Maximal rate conducted over AP was lower than in other locations. Absence of poorly-tolerated arrhythmias during follow-up and higher risk of ablation failure should be taken into account for indications of AP ablation in children with few symptoms.

  18. Remote Left Ventricular Hemodynamic Monitoring Using a Novel Intracardiac Sensor.

    Science.gov (United States)

    Mondritzki, Thomas; Boehme, Philip; White, Jason; Park, Jin Woo; Hoffmann, Jessica; Vogel, Julia; Kolkhof, Peter; Walsh, Stuart; Sandner, Peter; Bischoff, Erwin; Dinh, Wilfried; Hüser, Jörg; Truebel, Hubert

    2018-05-01

    Heart failure (HF) remains the most common reason for hospital admission in patients aged >65 years. Despite modern drug therapy, mortality and readmission rates for patients hospitalized with HF remain high. This necessitates further research to identify early patients at risk for readmission to limit hospitalization by timely adjustment of medical therapy. Implantable devices can monitor left ventricular (LV) hemodynamics and remotely and continuously detect the early signs of decompensation to trigger interventions and reduce the risk of hospitalization for HF. Here, we report the first preclinical study validating a new batteryless and easy to implant LV-microelectromechanical system to assess LV performance. A miniaturized implantable wireless pressure sensor was adapted for implantation in the LV apex. The LV-microelectromechanical system sensor was tested in a canine model of HF. The wireless pressure sensor measurements were compared with invasive left heart catheter-derived measurements at several time points. During different pharmacological challenge studies with dobutamine or vasopressin, the device was equally sensitive compared with invasive standard procedures. No adverse events or any observable reaction related to the implantation and application of the device for a period of 35 days was observed. Our miniaturized wireless pressure sensor placed in the LV (LV-microelectromechanical system) has the potential to become a new telemetric tool to earlier identify patients at risk for HF decompensation and to guide the treatment of patients with HF. © 2018 American Heart Association, Inc.

  19. Intra-cardiac masses in adults: A review of echocardiogram records ...

    African Journals Online (AJOL)

    2012-12-04

    Dec 4, 2012 ... TTE is the clinical procedure of choice for identification of left ventricular thrombi. TTE has ... The first effort to use pulse‑reflected ultrasound to examine .... masses was in a patient with lymphoma [Figures 5 and 6]. Table 1: Demographic characteristics of the patients and location of masses. Case number.

  20. Effect of tropicamide on ocular blood flow in the rabbit

    International Nuclear Information System (INIS)

    Delgado, D.; Michel, P.; Jaanus, S.D.

    1982-01-01

    Intracardiac injection of 15 microspheres labeled with 85 Sr (strontium) and 141 Ce (cerium) were used to determine ocular blood flow in seven rabbits before and 25 min after bilateral application of tropicamide to the cornea. By using two different isotopes distinguishable under gammaspectrometry, each animal served as its own control. After administration of two drops of 1% tropicamide, no significant difference in blood flow between treated and untreated eyes was observed

  1. Isthmus sites identified by Ripple Mapping are usually anatomically stable: A novel method to guide atrial substrate ablation?

    Science.gov (United States)

    Luther, Vishal; Qureshi, Norman; Lim, Phang Boon; Koa-Wing, Michael; Jamil-Copley, Shahnaz; Ng, Fu Siong; Whinnett, Zachary; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa; Linton, Nick

    2018-03-01

    Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach. © 2018 Wiley Periodicals, Inc.

  2. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  3. Wavelet-sparsity based regularization over time in the inverse problem of electrocardiography.

    Science.gov (United States)

    Cluitmans, Matthijs J M; Karel, Joël M H; Bonizzi, Pietro; Volders, Paul G A; Westra, Ronald L; Peeters, Ralf L M

    2013-01-01

    Noninvasive, detailed assessment of electrical cardiac activity at the level of the heart surface has the potential to revolutionize diagnostics and therapy of cardiac pathologies. Due to the requirement of noninvasiveness, body-surface potentials are measured and have to be projected back to the heart surface, yielding an ill-posed inverse problem. Ill-posedness ensures that there are non-unique solutions to this problem, resulting in a problem of choice. In the current paper, it is proposed to restrict this choice by requiring that the time series of reconstructed heart-surface potentials is sparse in the wavelet domain. A local search technique is introduced that pursues a sparse solution, using an orthogonal wavelet transform. Epicardial potentials reconstructed from this method are compared to those from existing methods, and validated with actual intracardiac recordings. The new technique improves the reconstructions in terms of smoothness and recovers physiologically meaningful details. Additionally, reconstruction of activation timing seems to be improved when pursuing sparsity of the reconstructed signals in the wavelet domain.

  4. Indium-111 platelet scintigraphy in carotid disease

    International Nuclear Information System (INIS)

    Branchereau, A.; Bernard, P.J.; Ciosi, G.; Bazan, M.; de Laforte, C.; Elias, A.; Bouvier, J.L.

    1988-01-01

    Forty-five patients (35 men, 10 women) undergoing carotid surgery had Indium-111 platelet scintigraphy as part of their preoperative work-up. Imaging was performed within three hours after injection of the Indium-111. A second series of views was obtained 24 hours later and repeated at 24 hour intervals for two days. Of 54 scintigrams, 22 were positive and 32 negative. Positive results were defined as a twofold or more increase in local activity on a visualized carotid after 24 hours. The sensitivity of the method was 41%, intraoperatively, and the specificity, 100%. The low sensitivity places this method behind sonography and duplex-scanning for screening patients for surgery. We believe that indications for platelet scintigraphy are limited to: 1. Repeated transient ischemic attacks in the same territory with minimal lesions on arteriography and non-homogeneous plaque on duplex scan; 2. Symptomatic patients being treated medically as a possible argument for surgery; 3. Determining therapeutic policy for patients having experienced a transient ischemic attack with a coexisting intracardiac thrombus

  5. [Camera-cinematography of the heart (author's transl)].

    Science.gov (United States)

    Adam, W E; Meyer, G; Bitter, F; Kampmann, H; Bargon, G; Stauch, M

    1975-07-01

    By "camera-cinematography" of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCi 99mTc human serum albumen followed after ten minutes by a five to ten minute period of observation with a scintilation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation.

  6. Camera-cinematography of the heart

    International Nuclear Information System (INIS)

    Adam, W.E.; Meyer, G.; Bitter, F.; Kampmann, H.; Bargon, G.; Stauch, M.; Ulm Univ.

    1975-01-01

    By 'camera-cinematography' of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCisup(99m)Tc human serum albumin followed after ten minutes by a five to ten minute period of observation with a scintillation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation. (orig.) [de

  7. Myocardial function during transesophageal cardiac pacing in patients with coronary heart diseases when selected for surgical management: nuclear stethoscopic findings

    International Nuclear Information System (INIS)

    Fitilev, S.B.; Mironova, M.A.; Gordeev, V.F.; Satrapinskij, V.Yu.; Badalyan, E.A.; Akademiya Meditsinskikh Nauk SSSR, Moscow

    1991-01-01

    Studies of myocardial function during transesophageal cardiac pacing (TECP) were carried out in 70 patients with coronary heart diseases (CHD). All the patients were examined for central and intracardiac hemodynamics during TECP using nuclear stetoscope Bios (USA). The obtained data of central hemodynamics and myocardium contractibility make it possible to judge not only of pathological hemodynamics changes, as a CHD diagnostic factor, but of factors limiting reserve of cardiovascular system as well, depending on morphological heart changes

  8. Evaluation of Hydatid Disease of the Heart with Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Kotoulas, Grigoris K.; Magoufis, George L.; Gouliamos, Athanasios D.; Athanassopoulou, Alexandra K.; Roussakis, Arcadios C.; Koulocheri, Dimitra P.; Kalovidouris, Angelos; Vlahos, Labros

    1996-01-01

    Two patients with cardiac involvement of hydatid disease are presented: one with hydatid cyst of the interventricular septum and pulmonary arteries and the other with multiple pulmonary cysts associated with intracardiac and pericardial cysts. The ability of magnetic resonance imaging (MRI) to provide a global view of cardiac anatomy in any plane with high contrast between flowing blood and soft tissue ensures it an important role in the diagnosis and preoperative assessment of hydatid disease of the heart

  9. An unusual outcome of a right atrium wall abscess in an infant. A case report

    Directory of Open Access Journals (Sweden)

    F. Jebri

    2015-12-01

    Full Text Available Echocardiography is known as an accurate tool for the diagnosis of myocardial abscess (MA. Surgery resection is compulsory as therapy for this intracardiac mass. Though, we report the first case in an infant, of a right auricular MA without valvular involvement, diagnosed retrospectively in a occasion of a purulent pericarditis, leaving place spontaneously to a new cavity and displacing the tricuspid ring. Treatment is not codified and remains different depending on each case.

  10. Ablation of hypertrophic septum using radiofrequency energy: an alternative for gradient reduction in patient with hypertrophic obstructive cardiomyopathy?

    Science.gov (United States)

    Riedlbauchová, Lucie; Janoušek, Jan; Veselka, Josef

    2013-06-01

    Alcohol septal ablation and surgical myectomy represent accepted therapeutic options for treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy. Long-term experience with radiofrequency ablation of arrhythmogenic substrates raised a question if this technique might be effective for left ventricular outflow tract (LVOT) gradient reduction. We report on a 63-year-old patient with recurrence of symptoms 1 year after alcohol septal ablation (ASA) leading originally to a significant reduction of both symptoms and gradient. Due to a new increase of gradient in the LVOT up to 200 mm Hg with corresponding worsening of symptoms and due to refusal of surgical myectomy by the patient, endocardial radiofrequency ablation of the septal hypertrophy (ERASH) was indicated. Radiofrequency ablation was performed in the LVOT using irrigated-tip ablation catheter; the target site was identified using intracardiac echocardiography and electroanatomical CARTO mapping. ERASH caused an immediate gradient reduction due to hypokinesis of the ablated septum. At 2-month follow-up exam, significant clinical improvement was observed, together with persistent gradient reduction assessed with Doppler echocardiography. Echocardiography and magnetic resonance revealed persistent septal hypokinesis and slight thinning of the ablated region. Septal ablation using radiofrequency energy may be a promising alternative or adjunct to the treatment of hypertrophic obstructive cardiomyopathy. Intracardiac echocardiography and electroanatomical CARTO mapping enable exact lesion placement and preservation of atrioventricular conduction.

  11. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  12. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  13. Multidetector CT for congenital heart patients: what a paediatric radiologist should know

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jean-Francois; Rohnean, Adela; Sigal-Cinqualbre, Anne [Radiology Unit, Marie Lannelongue Hospital, Plessis-Robinson (France)

    2010-06-15

    Multidetector CT (MDCT) is increasingly used for imaging congenital heart disease (CHD) patients in addition to echocardiography, due to its ability to provide high quality three-dimensional images, giving a comprehensive evaluation of complex heart malformations. Using 4-slice or 16-slice CT, diagnostic information in CHD patients is limited to extra-cardiac anatomy, mainly the pulmonary arteries, aorta and venous connections. Due to high heart rates in babies however, coronary evaluation and intra-cardiac analysis were not reliable with the first generations of MDCT. Larger detector size with 64-slice CT and faster acquisition time, up to 75 ms for one slice, has progressively improved coronary and intra-cardiac visualization. Because radiation dose is the main concern, especially in children, every attempt to minimize dose whilst preserving image quality is important: the ALARA concept should always be applied in this population. The 80 kVp setting is now well accepted as a standard for more and more radiological teams involved in CT of children. Different acquisition strategies are now possible for childhood coronary imaging, using retrospective or even prospective gating. Using the latest technology, sub-mSv acquisitions are now attainable for scanning a whole thorax, providing a complete analysis of any 3-D cardiac malformation, including coronary artery course visualisation. This review will describe how technological developments have improved image quality with continuous reduction of radiation dose. (orig.)

  14. Morphological characteristic of surgically removed cardiac myxomas: 25-YEAR EXPERIENCE IN V.I. SHUMAKOV FEDERAL RESEARCH CENTER OF TRANSPLANTOLOGY AND ARTIFICIAL ORGANS

    Directory of Open Access Journals (Sweden)

    I. M. Iljinsky

    2017-01-01

    Full Text Available Analysis of intracardiac space-occupying lesions, surgically removed at V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs over 25 years (in the period from 1992 until 2016 was carried out. During that period 134 patients underwent surgery. Preoperative clinical diagnosis before surgery was heart myxoma. From 134 patients, only in 115 (85.8% patients the removed intracardiac lesions were myxomas: left atrium – 103 (89.7% patients, right atrium – 10 (8.7%, right ventricle – 2 (1.8% and mitral valve – 1 (0.8% patient. 9 patients had thrombi in the heart, 10 patients had not myxomas, but other benign and malignant heart tumors. This article presents macroscopic, histolological and ultrastructural characteristic of cardiac myxomas. Recurrence of the left atrium myxoma occurred in 2 patients. They were re-operated in four and six years after the first removal of myxoma. 2 patients died during hospital period. One patient with atherosclerosis of the coronary arteries as a concurrent disease died of embolization of the stent coronary artery with myxoma particles with the development of acute heart failure. Death of the 2nd patient was not directly related to the surgery, and was due to the acute heart failure as well in connection with the presence of concurrent disease, coronary heart disease.

  15. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  16. Zoledronic acid preserves bone structure and increases survival but does not limit tumour incidence in a prostate cancer bone metastasis model.

    Directory of Open Access Journals (Sweden)

    Tzong-Tyng Hung

    Full Text Available BACKGROUND: The bisphosphonate, zoledronic acid (ZOL, can inhibit osteoclasts leading to decreased osteoclastogenesis and osteoclast activity in bone. Here, we used a mixed osteolytic/osteoblastic murine model of bone-metastatic prostate cancer, RM1(BM, to determine how inhibiting osteolysis with ZOL affects the ability of these cells to establish metastases in bone, the integrity of the tumour-bearing bones and the survival of the tumour-bearing mice. METHODS: The model involves intracardiac injection for arterial dissemination of the RM1(BM cells in C57BL/6 mice. ZOL treatment was given via subcutaneous injections on days 0, 4, 8 and 12, at 20 and 100 µg/kg doses. Bone integrity was assessed by micro-computed tomography and histology with comparison to untreated mice. The osteoclast and osteoblast activity was determined by measuring serum tartrate-resistant acid phosphatase 5b (TRAP 5b and osteocalcin, respectively. Mice were euthanased according to predetermined criteria and survival was assessed using Kaplan Meier plots. FINDINGS: Micro-CT and histological analysis showed that treatment of mice with ZOL from the day of intracardiac injection of RM1(BM cells inhibited tumour-induced bone lysis, maintained bone volume and reduced the calcification of tumour-induced endochondral osteoid material. ZOL treatment also led to a decreased serum osteocalcin and TRAP 5b levels. Additionally, treated mice showed increased survival compared to vehicle treated controls. However, ZOL treatment did not inhibit the cells ability to metastasise to bone as the number of bone-metastases was similar in both treated and untreated mice. CONCLUSIONS: ZOL treatment provided significant benefits for maintaining the integrity of tumour-bearing bones and increased the survival of tumour bearing mice, though it did not prevent establishment of bone-metastases in this model. From the mechanistic view, these observations confirm that tumour-induced bone lysis is not a

  17. Infectious endocardial intracardiac defibrillator lead, infectious pericarditis, and delayed constrictive pericarditis

    Directory of Open Access Journals (Sweden)

    Mohsen Mir Mohammad Sadeghi

    2013-01-01

    Full Text Available The usage of Implantable Cardiac Defibrillator (ICD since 1980s is becoming more popular these days. The rate of both, endocarditis and constrictive pericarditis are low but it still needs attention. We are reporting a rare case of ICD endocarditis as a result of toe infection in a diabetic patient. This was followed by infectious pericarditis after device removal by open heart surgery and then delayed constrictive pericarditis.

  18. Heparin-Induced Thrombocytopenia Associated with Massive Intracardiac Thrombosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Atheer Ahmed

    2012-01-01

    Full Text Available A 60-years old patient was admitted to a community hospital with septic arthritis. He was treated with antibiotics and subcutaneous unfractionated heparin (UH was used for venous thromboprophylaxis. After three days, he developed leg deep venous thrombosis and was treated with IV heparin. One day later, the patient developed pulmonary emboli, which was found using ventilation/perfusion scan. He was transferred to the University Hospital for further management. Upon arrival, antibiotic and intravenous UH were continued. Trans-Esophageal Echocardiogram showed a thrombus in the right atrium, a small portion of which extended to the left atrium through a patent foramen ovale. Another large thrombus was noted in the right ventricle, which extended to the pulmonary artery. Review of the patient’s medical records revealed a halving of his platelet count three days following the heparin administration. Therefore, HIT seemed very likely. Intravenous UH was stopped and an emergency thrombectomy was performed. ELISA testing of HIT antibodies came negative. This made HIT diagnosis unlikely and the patient received dalteparin. A week later, as the platelet count declined again, HIT antibodies’ testing using ELISA and C-14 serotonin release was repeated, and both assays were positive. Argatroban was restarted and the platelet count normalized.

  19. Significance of spin-echo intracardiac signal during cine cardiac MR imaging

    International Nuclear Information System (INIS)

    Feiglin, D.H.I.; O'Donnell, J.K.

    1987-01-01

    Thirty patient studies were performed using several multisection spin multi-echo pulse sequences (SEPS) formattable into the cine mode, with repetition time (TR)≤RR interval and 18 msec ≤ echo time (TE) ≤ 64 msec. Thirteen studies were performed in patients with various cardiomyopathies, ten in patients with cardiac tumors, and seven in healthy volunteers. The SEPS in the multi-echo acquisition format differentiated between tumor and stasis in terms of signal behavior. Healthy subjects may exhibit stasis of flow adjacent to the endocardium during the cardiac cycle

  20. Quantifying the determinants of decremental response in critical ventricular tachycardia substrate.

    Science.gov (United States)

    Beheshti, Mohammadali; Nayyar, Sachin; Magtibay, Karl; Massé, Stéphane; Porta-Sanchez, Andreu; Haldar, Shouvik; Bhaskaran, Abhishek; Vigmond, Edward; Nanthakumar, Kumaraswamy

    2018-05-28

    Decremental response evoked with extrastimulation (DEEP) is a useful tool for determining diastolic return path of ventricular tachycardia (VT). Though a targeted VT ablation is feasible with this approach, determinants of DEEP response have not been studied OBJECTIVES: To elucidate the effects of clinically relevant factors, specifically, the proximity of the stimulation site to the arrhythmogenic scar, stimulation wave direction, number of channels open in the scar, size of the scar and number of extra stimuli on decrement and entropy of DEEP potentials. In a 3-dimensional bi-domain simulation of human ventricular tissue (TNNP cell model), an irregular subendocardial myopathic region was generated. An irregular channel of healthy tissue with five potential entry branches was shaped into the myopathic region. A bipolar electrogram was derived from two electrodes positioned in the centre of the myopathic region. Evoked delays between far-field and local Electrogram (EGM) following an extrastimulus (S1-S2, 500-350 ms) were measured as the stimulation site, channel branches, and inexcitable tissue size were altered. Stimulation adjacent to the inexcitable tissue from the side opposite to the point-of-entry produces longest DEEP delay. The DEEP delay shortens when the stimulation point is farther away from the scar, and it decreases maximally when stimulation is done from a site beside a conduction barrier. Entropy increases with S2 when stimulation site is from farther away. An unprotected channel structure with multiple side-branch openings had shorter DEEP delay compared to a protected channel structure with a paucity of additional side-branch openings and a point-of-entry on the side opposite to the pacing source. Addition of a second shorter extrastimulus did not universally lead to higher DEEP delay CONCLUSIONS: Location and direction of the wavefront in relation to scar entry and size of scar determine the degree of evoked response while the number of

  1. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  2. [Isolated mitral valve insufficiency in comparison with mitral-tricuspid insufficiency: various mechanisms of compensating for the defect and functional status of the myocardium].

    Science.gov (United States)

    Petrovskiĭ, P F; Torbina, A M; Klemborskiĭ, A A

    1988-09-01

    A combined analysis of ventricular contractility and intracardiac hemodynamic compensatory mechanisms was carried out, on the basis of angiocardiographic findings, in 37 patients with rheumatic mitral incompetence. Atrial fibrillation aggravates essentially the defect's hemodynamics, while added tricuspid incompetence is accompanied by a certain off-loading in the lesser circulation network. A grossly perversed phasic structure of intramyocardial stress was noted, apparently being a compensatory mechanism. Reduced specific coronary flow and diastolic perfusion gradient in intact coronary arteries are shown to be causes of clinical angina.

  3. Correção simultânea de defeito congênito intracardíaco e pectus excavatum Simultaneous repair of congenital heart defect and pectus excavatum

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-09-01

    Full Text Available Relatamos tratamento simultâneo de pectus excavatum e defeito congênito intracardíaco representado por comunicação interatrial ostium secundum. Paciente do sexo masculino, 8 anos de idade, com diagnóstico clínico e ecocardiográfico de comunicação interatrial, associada à deformidade da parede torácica tipo pectus excavatum. Foi encaminhado para operação com correção simultânea do defeito congênito intracardíaco associado ao reparo do pectus. O tratamento operatório simultâneo do pectus excavatum e defeitos congênitos intracardíacos torna difícil o acesso ao coração. Foi feita a correção simultânea dessas alterações, com satisfatório resultado, sobretudo estético, para o paciente.The author describes the simultaneous treatment of pectus excavatum and congenital intracardiac defect (atrial septal defect represented by the interatrial foramen secundum. An 8-year-old boy, with clinical and echocardiography diagnosis of atrial septal defect associated with pectus excavatum was referred to a simultaneous surgical treatment of both abnormalities. The simultaneous surgical treatment of both pectus excavatum and congenital intracardiac defects make it difficult to access the heart. In this case, the simultaneous surgical treatment of atrial septal defect and pectus excavatum was a valuable alternative to surgical repair of both abnormalities, mainly due to its cosmetic outcome.

  4. Zebrafish heart as a model to study the integrative autonomic control of pacemaker function

    Science.gov (United States)

    Stoyek, Matthew R.; Quinn, T. Alexander; Croll, Roger P.

    2016-01-01

    The cardiac pacemaker sets the heart's primary rate, with pacemaker discharge controlled by the autonomic nervous system through intracardiac ganglia. A fundamental issue in understanding the relationship between neural activity and cardiac chronotropy is the identification of neuronal populations that control pacemaker cells. To date, most studies of neurocardiac control have been done in mammalian species, where neurons are embedded in and distributed throughout the heart, so they are largely inaccessible for whole-organ, integrative studies. Here, we establish the isolated, innervated zebrafish heart as a novel alternative model for studies of autonomic control of heart rate. Stimulation of individual cardiac vagosympathetic nerve trunks evoked bradycardia (parasympathetic activation) and tachycardia (sympathetic activation). Simultaneous stimulation of both vagosympathetic nerve trunks evoked a summative effect. Effects of nerve stimulation were mimicked by direct application of cholinergic and adrenergic agents. Optical mapping of electrical activity confirmed the sinoatrial region as the site of origin of normal pacemaker activity and identified a secondary pacemaker in the atrioventricular region. Strong vagosympathetic nerve stimulation resulted in a shift in the origin of initial excitation from the sinoatrial pacemaker to the atrioventricular pacemaker. Putative pacemaker cells in the sinoatrial and atrioventricular regions expressed adrenergic β2 and cholinergic muscarinic type 2 receptors. Collectively, we have demonstrated that the zebrafish heart contains the accepted hallmarks of vertebrate cardiac control, establishing this preparation as a viable model for studies of integrative physiological control of cardiac function by intracardiac neurons. PMID:27342878

  5. Echocardiographic Diagnostics of Myocardial Infarction in Newborns

    Directory of Open Access Journals (Sweden)

    G. V. Revunenkov

    2015-01-01

    Full Text Available Early and correct diagnostics of myocardial infarction in newborns is impossible without modern instrumental methods, among which echocardiography is the leading one. Hypokinesia, akinesia or dyskinesia of local segments of the heart ventricular wall is determined with echocardiography. We examined a 3-days-old baby with circulatory failure requiring cardiotonic support. On auscultation there was a heart murmur. It was an intracardiac conduction disoder and infarction-like changes on ECG, however, a convincing evidence to interpret the patient’s condition as myocardial infarction has not been received. Therefore, it was decided to conduct echocardiography. According to the results of echocardiography the presence of hyperechogenic diskinetic locus in the apical segment of the right ventricle (post-infarction scar, a local pericardial effusion in the same projection, hyperechogenic movable mass (thrombus in the apical segment of the right ventricle were determined that together with the results of the ECG allowed us to set diagnosis myocardial infarction. Transthoracic echocardiography is one of highly informative methods; the data obtained allowed to correctly interpret the clinical picture of heart failure and to reveal the cause of the patien’st dependance on cardiotonic support.

  6. Raman spectroscopy technology to monitor the carotenoids in skin of thalassemia patients: a novel non-invasive tool relating oxidative stress with iron burden

    Directory of Open Access Journals (Sweden)

    Anna Perrone

    2014-09-01

    Full Text Available In this work we approach the relationship between redox state and iron overload by noninvasive instrumental techniques. Intracardiac, liver iron and liver fibrosis have been monitored in transfusion-dependent thalassemia patients by magnetic resonance imaging and hepatic transient elastography examinations. These measurements have been matched with a non-invasive, and yet unexplored in clinical practice, evaluation of body’s oxidative stress through measurement of antioxidant carotenoids in skin, by a spectroscopic method based on Raman technology (RRS. The global body’s antioxidant status results from a balance between the level of antioxidants in cells and body fluids, including blood, and pro-oxidant species endogenously produced or coming from external sources. On this basis, the level of skin carotenoids can be considered a biomarker of the entire antioxidant status. In our work the use of RRS method provided information on the redox state of thalassemia patients, which was correlated with the iron status of the patients. Due to the highly adverse effects of accumulated iron, the novel, simple, non-invasive RRS to monitor dermal carotenoids with high compliance of the patients may be a useful tool for the management of thalassemia patients.

  7. Caseous mitral annular calcification mimicking a lung tumor on chest X-ray

    Directory of Open Access Journals (Sweden)

    Philip Dingli

    2017-01-01

    Full Text Available Mitral annular calcification (MAC is a common condition of the mitral valve apparatus. A case involving caseous calcification, a rare variant of MAC is presented. This variant which has a benign course can present as an intracardiac mass and needs to be differentiated from more sinister causes of calcified cardiac masses such as tumor, abscess, and infective vegetation. Often, this requires multimodality imaging with echocardiography, computed tomography, and magnetic resonance imaging. Features of caseous calcification of the mitral valve on these imaging modalities are reviewed as the associations and clinical features.

  8. One-stage repair of tetralogy of Fallot with coarctation of the aorta.

    Science.gov (United States)

    Makhija, Zeena; Radhakrishnan, Sitaraman; Goel, Apporva; Sharma, Rajesh

    2014-09-01

    We describe the rare case of a 10-month-old girl who had coarctation of the aorta in association with tetralogy of Fallot. The surgical management and postoperative course is described. This case highlights the rare association of coarctation with tetralogy of Fallot, with a large intracardiac right-to-left shunt. Although an exception to the rule, it challenges the reduced fetal blood flow theory and the smooth muscle cell migration theory as embryological explanations for the development of coarctation. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Significance of computed tomography for diagnosis of heart diseases

    International Nuclear Information System (INIS)

    Senda, Kohei; Sakuma, Sadayuki

    1983-01-01

    Computed tomography (CT) with a 2 sec scanner was carried out on 105 cases with various heart disease in order to detect CT findings in each heart disease. Significance of CT as a imaging study was evaluated in comparison with scintigraphic, echographic and roentgenographic studies. CT with contrast enhancement in moderate inspiration was able to demonstrate accurately organic changes of intra-and extracardiac structure. Comparing with other imaging studies, CT was superior in detection of calcified or intracardiac mass lesion in spite of low value in evaluating cardiac function or dynamics. (author)

  10. Miniaturized Ultrasound Imaging Probes Enabled by CMUT Arrays with Integrated Frontend Electronic Circuits

    Science.gov (United States)

    Khuri-Yakub, B. (Pierre) T.; Oralkan, Ömer; Nikoozadeh, Amin; Wygant, Ira O.; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N.; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O’Donnell, Matthew; Truong, Uyen; Sahn, David J.

    2010-01-01

    Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics. PMID:21097106

  11. Nuclear magnetic resonance imaging in patients with hypertrophic and dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Boisvieux, A.

    1987-01-01

    Patients with hypertrophic and dilated cardiomyopathy and normal subjects were investigated with nuclear magnetic resonance imaging. To evaluate the NMR scanner possibilities, the results were compared with the echocardiographic investigation of the same patients. The capabilities of NMR imaging to provide information about intracardiac anatomy are emphasized. This study is preceded by a description of the physical principles underlying the phenomenon of nuclear magnetic resonance and of the techniques used to obtain NMR images and a review of the clinical use of NMR imaging for cardiac diagnosis [fr

  12. Effects of lodoxamide (LOD), disodium cromoglycate (DSCG) and N-acetyl-aspartyl-glutamate sodium salt (NAAGA) on ocular active anaphylaxis.

    Science.gov (United States)

    Goldschmidt, P; Luyckx, J

    1996-04-01

    LOD, DSCG and NAAGA eye-drops were evaluated on experimentally-induced ocular active anaphylaxis in guinea pigs. Twelve animals per group were sensitized with egg albumin i.p. and challenged on the surface of the eye 14 days later. Two days before challenge, animals were treated with LOD, DSCG or NAAGA 4 times a day. Permeability indexes were calculated after intracardiac injection of Evans Blue. No effect on ocular active anaphylaxis was found with LOD nor with DSCG. NAAGA was able to significantly reduce blood-eye permeability indexes.

  13. Self powered pacers and stimulators

    International Nuclear Information System (INIS)

    Rasor, N.S.; Spickler, J.W.

    1976-01-01

    A simulator device is described for insertion in a living body, having particular advantage for intracardiac use comprising a housing having a body formed for transvenous or transarterial insertion, electrode means at the outer surface of said body, means included in said housing defining a pulsing circuit electrically connected with said electrode means and means for activating said pulsing circuit embodied in said housing, said activating means being free of physical connection with an outside power source and dependent for its function on the living body in which it is inserted

  14. Central hemodynamics and left-ventricural contractility in patients with chronic obstructive pulmonary diseases and stable pulmonary hypertension: a radionuclide study

    International Nuclear Information System (INIS)

    Paleev, N.R.; Malov, G.A.; Cherejskaya, N.K.; Oblovatskaya, O.G.; Tsar'kova, L.N.; Zil'berman, E.Eh.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Serdechno-Sosudistoj Khirurgii)

    1987-01-01

    Systemic, central and intracardiac hemodynamics and left-ventricular contractility were studied radiocardiographically and radioventriculographically in 22 patients with stable pulmanory hypertension, developing in the presence of chronic obstructive pulmanory diseases. A tendency to increased circulating blood volume, significantly elevated end diastolic and end systolic indices, reduced total ejection fraction, and a tendency to decreased segmental ejection fractions were demonstrated. A significant reduction of the speed and percetage of left-ventricular myocardial circular fibre contraction is another evedence of incompetent left-ventricular contractility, in addition to the reduced ejection fraction

  15. Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force.

    Science.gov (United States)

    Arai, Marina; Fukamizu, Seiji; Kawamura, Iwanari; Miyazawa, Satoshi; Hojo, Rintaro; Sakurada, Harumizu; Hiraoka, Masayasu

    2018-04-01

    The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.

  16. Staphylococcus aureus endocarditis with fast development of aortic root abscess despite relevant antibiotics

    DEFF Research Database (Denmark)

    Dahl, Anders; Hansen, Thomas Fritz; Bruun, Niels Eske

    2013-01-01

    We present a case of Staphylococcus aureus endocarditis in which a large abscess was formed in only 4 days, despite specific intravenous antibiotics and only few vague signs of disease progression. Our case seems to be the first to show echocardiographic documentation of how quickly an intracardiac...... abscess can develop despite relevant antibiotics. Clinically, the patient is remarkably unaffected, and thus even small signs of progression should lead to considerations about repeating the diagnostic imaging workup. This case illustrates how aggressive an infection S. aureus endocarditis may be...

  17. Utility of unipolar recordings for complex Wolff–Parkinson–White ablation

    Directory of Open Access Journals (Sweden)

    Ponnusamy Shunmuga Sundaram

    2015-03-01

    Full Text Available Radiofrequency ablation has been shown to be a safe and effective treatment strategy for the management of symptomatic patients with Wolff–Parkinson–White syndrome. It is supported by a success rate of 95% and a recurrence rate of less than 5%. However, ablation of accessory pathways can be challenging at times. The causes for failure can be grouped into three categories – unusual location of the pathway, technical difficulties in delivering the ablation and localization error [1]. In this case report we are reporting a case of a young male who presented to us with symptomatic Wolff–Parkinson–White syndrome with two failed prior ablations at another institution. This case illustrates the importance of knowing accurate localization and course of the accessory pathway by utilizing the unipolar and bipolar electrograms simultaneously during radiofrequency ablation.

  18. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  19. Angiotensin II potentiates adrenergic and muscarinic modulation of guinea pig intracardiac neurons.

    Science.gov (United States)

    Girasole, Allison E; Palmer, Christopher P; Corrado, Samantha L; Marie Southerland, E; Ardell, Jeffrey L; Hardwick, Jean C

    2011-11-01

    The intrinsic cardiac plexus represents a major peripheral integration site for neuronal, hormonal, and locally produced neuromodulators controlling efferent neuronal output to the heart. This study examined the interdependence of norepinephrine, muscarinic agonists, and ANG II, to modulate intrinsic cardiac neuronal activity. Intracellular voltage recordings from whole-mount preparations of the guinea pig cardiac plexus were used to determine changes in active and passive electrical properties of individual intrinsic cardiac neurons. Application of either adrenergic or muscarinic agonists induced changes in neuronal resting membrane potentials, decreased afterhyperpolarization duration of single action potentials, and increased neuronal excitability. Adrenergic responses were inhibited by removal of extracellular calcium ions, while muscarinic responses were inhibited by application of TEA. The adrenergic responses were heterogeneous, responding to a variety of receptor-specific agonists (phenylephrine, clonidine, dobutamine, and terbutaline), although α-receptor agonists produced the most frequent responses. Application of ANG II alone produced a significant increase in excitability, while application of ANG II in combination with either adrenergic or muscarinic agonists produced a much larger potentiation of excitability. The ANG II-induced modulation of firing was blocked by the angiotensin type 2 (AT(2)) receptor inhibitor PD 123319 and was mimicked by the AT(2) receptor agonist CGP-42112A. AT(1) receptor blockade with telmasartin did not alter neuronal responses to ANG II. These data demonstrate that ANG II potentiates both muscarinically and adrenergically mediated activation of intrinsic cardiac neurons, doing so primarily via AT(2) receptor-dependent mechanisms. These neurohumoral interactions may be fundamental to regulation of neuronal excitability within the intrinsic cardiac nervous system.

  20. Intrinsic and extrinsic innervation of the heart in zebrafish (Danio rerio).

    Science.gov (United States)

    Stoyek, Matthew R; Croll, Roger P; Smith, Frank M

    2015-08-01

    In the vertebrate heart the intracardiac nervous system is the final common pathway for autonomic control of cardiac output, but the neuroanatomy of this system is not well understood. In this study we investigated the innervation of the heart in a model vertebrate, the zebrafish. We used antibodies against acetylated tubulin, human neuronal protein C/D, choline acetyltransferase, tyrosine hydroxylase, neuronal nitric oxide synthase, and vasoactive intestinal polypeptide to visualize neural elements and their neurotransmitter content. Most neurons were located at the venous pole in a plexus around the sinoatrial valve; mean total number of cells was 197 ± 23, and 92% were choline acetyltransferase positive, implying a cholinergic role. The plexus contained cholinergic, adrenergic, and nitrergic axons and vasoactive intestinal polypeptide-positive terminals, some innervating somata. Putative pacemaker cells near the plexus showed immunoreactivity for hyperpolarization-activated cyclic nucleotide-gated channel 4 (HCN4) and the transcription factor Islet-1 (Isl1). The neurotracer neurobiotin showed that extrinsic axons from the left and right vagosympathetic trunks innervated the sinoatrial plexus proximal to their entry into the heart; some extrinsic axons from each trunk also projected into the medial dorsal plexus region. Extrinsic axons also innervated the atrial and ventricular walls. An extracardiac nerve trunk innervated the bulbus arteriosus and entered the arterial pole of the heart to innervate the proximal ventricle. We have shown that the intracardiac nervous system in the zebrafish is anatomically and neurochemically complex, providing a substrate for autonomic control of cardiac effectors in all chambers. © 2015 Wiley Periodicals, Inc.

  1. Atrial myxoma presenting with orthostatic hypotension in an 84-year-old Hispanic man: a case report

    Directory of Open Access Journals (Sweden)

    Halstead Michael

    2009-12-01

    Full Text Available Abstract Introduction Left atrial myxomas remain the most common benign primary cardiac tumors, and these cardiac growths can masquerade as mitral stenosis, infective endocarditis and collagen vascular disease. Atrial myxomas are found in approximately 14-20% of the population and can lead to embolization, intercardiac obstructions, conduction disturbances and lethal valve obstructions. Case presentation An 84-year-old Hispanic man presented with complaints of dizziness upon standing, and with no prior history of heart murmurs, syncope, shortness of breath, or chest pain. Physical examination revealed evidence of orthostatic hypotension and a soft grade 1/6 systolic murmur at the left sternal border. A transthoracic echocardiogram revealed a large atrial myxoma occupying the majority of the left atrium, with the posterior border of the large atrial mass defined by eccentric mitral regurgitation identified during cardiac catheterization. Left atrial myxoma excision was performed, revealing a 7 × 6.5 × 4.5 cm atrial tumor attached to a 4 × 3 × 2 cm stalk of atrial septal tissue. Conclusion This patient didn't present with the common symptoms associated with an atrial myxoma, which may include chest pain, dyspnea, orthopnea, peripheral embolism or syncope. Two-dimensional echocardiography provides substantial advantages in detecting intracardiac tumors. We recommend a two-dimensional echocardiogram in the workup of orthostatic hypotension of unknown etiology after the common causes such as autonomic disorders, dehydration, and vasodilative dysfunctions have been ruled out. By illustrating this correlation between orthostasis and an atrial myxoma, we hope to facilitate earlier identification of these intracardiac growths.

  2. Incidence of ventricular tachyarrhythmias during permanent pacemaker therapy in low-risk patients results from the German multicentre EVENTS study.

    Science.gov (United States)

    Faber, Thomas S; Gradinger, Robert; Treusch, Sven; Morkel, Carsten; Brachmann, Johannes; Bode, Christoph; Zehender, Manfred

    2007-09-01

    Current studies found an incidence of 12-31% ventricular tachyarrhythmias and sudden cardiac death during cardiac pacing months or even years after pacemaker insertion. MADIT(12) and MUSTT(13) demonstrated that patients with poor LV function after Myocardial infarction (MI) showing non-sustained ventricular tachycardia (nsVT) and inducibility during electrophysiologic testing benefit from an ICD. The present study was dedicated to assess the global incidence of non-sustained ventricular arrhythmias in a general population of pacemaker patients. Special regard was on patients with a potential ICD indication, e.g. those matching the MADIT/MUSTT criteria. Two hundred and thirty-one patients (72 +/- 11 years; 134 men) with an indication for dual chamber pacing entered the study. In all patients pacemaker systems capable of automatic storing of intracardiac electrocardiograms were implanted (Pulsar, Discovery, Guidant). Follow-up time was 15 months after inclusion. In 54 (25.7%) of 210 patients with at least one follow-up, episodes of nsVT were documented by stored electrocardiograms (up to >30 beats, >200 b.p.m.). Multiple-up to nine-episodes of ventricular tachycardia were retrieved in 31 of these patients. Three out of 14 patients with an LVEF <40% after MI presented nsVT during the follow-up. One of these patients received an ICD. A significant number of pacemaker patients present with ventricular tachycardia. Intracardiac electrocardiograms and alert functions from pacemakers may enhance physicians' awareness of the patient's intrinsic arrhythmic profile and help uncover underlying mechanisms of arrhythmias by storing the initiation of the arrhythmia.

  3. Repair of Isolated Mitral Papillary Muscle Rupture Consequent to Blunt Trauma in a Small Child

    Science.gov (United States)

    Hazan, Eyup; Guzeloglu, Mehmet; Sariosmanoglu, Nejat; Ugurlu, Baran; Keskin, Vehip; Unal, Nurettin

    2009-01-01

    Blunt thoracoabdominal trauma is most often caused by high-velocity motor-vehicle accidents or by falls from a height. The clinical spectrum of cardiac injuries arising from this type of trauma varies from myocardial contusion to valvular rupture. Intracardiac valvular rupture is rarely observed, and few cases have been reported. The youngest of the patients in cases reported to date was 6 years of age. Here we report the case of a 2½year-old child, who sustained mitral valve insufficiency due to isolated rupture of the posterior mitral papillary muscle, which developed after a domestic accident. PMID:19568400

  4. [Campylobacter fetus subspecies fetus endoaortitis on a Bentall tube prosthesis. Apropos of a case].

    Science.gov (United States)

    Abassade, P; Crémieux, O; Korach, J M; Templier, F; Morette, C; Wolff, M; Baudouy, P Y; Farge, C

    1994-11-01

    Campylobacter fetus is a rare cause of endocarditis and endoaortitis: the authors believe this to be the second reported case of infection of an intracardiac prosthesis. The patient was a man who had already undergone replacement of the aortic valve and ascending aorta, and a gastrectomy, which were predisposing factors. The portal of entry was not found. The diagnosis was confirmed by positive blood cultures and transoesophageal echocardiography. The outcome was rapidly fatal despite antibiotic therapy and surgery, because of the seriousness of the lesions (pseudo-aneurysm of the aorta ruptured into the right atrium), the precarity of the terrain and surgical difficulties.

  5. Acquired ventricular septal defect due to infective endocarditis

    Directory of Open Access Journals (Sweden)

    Randi E Durden

    2018-01-01

    Full Text Available Acquired intracardiac left-to-right shunts are rare occurrences. Chest trauma and myocardial infection are well-known causes of acquired ventricular septal defect (VSD. There have been several case reports describing left ventricle to right atrium shunt after infective endocarditis (IE. We present here a patient found to have an acquired VSD secondary to IE of the aortic and tricuspid valves in the setting of a known bicuspid aortic valve. This is the first case reported of acquired VSD in a pediatric patient in the setting of IE along with literature review of acquired left-to-right shunts.

  6. Polymicrobial infective endocarditis caused by Neisseria sicca and Haemophilus parainfluenzae

    Directory of Open Access Journals (Sweden)

    Nikoloz Koshkelashvili

    2016-01-01

    Full Text Available Infective endocarditis is a common clinical problem in industrialized countries. Risk factors include abnormal cardiac valves, a history of endocarditis, intracardiac devices, prosthetic valves and intravenous drug use. We report a case of polymicrobial infective endocarditis in a 33 year-old female with a history chronic heroin use caused by Neisseria sicca and Haemophilus parainfluenzae. We believe the patient was exposed to these microbes by cleansing her skin with saliva prior to injection. Pairing a detailed history with the consideration of atypical agents is crucial in the proper diagnosis and management of endocarditis in patients with high-risk injection behaviors.

  7. Simultaneous transcatheter closure of intralobar pulmonary sequestration and patent ductus arteriosus in a patient with infantile Scimitar syndrome.

    Science.gov (United States)

    Aslan, Eyüp; Tanıdır, İbrahim Cansaran; Saygı, Murat; Onan, Sertaç Hanedan; Güzeltaş, Alper

    2015-03-01

    Scimitar syndrome is a rare disease associated with a right lung sequestration vascularised by arteries arising from the abdominal aorta and abnormal venous drainage into the inferior vena cava. The infantile form is generally presented with severe heart failure, pulmonary hypertension and respiratory distress. It may be associated with various intracardiac defects, including atrial septal defects, ventricular septal defects, patent ductus arteriosus or more complicated structural congenital heart defects. Here, we present a 2-month-old girl with Scimitar syndrome whose pulmonary arterial pressure decreased after transcatheter patent ductus arteriosus closure and embolization of the anomalous systemic arterial supply.

  8. Pulmonary damage following right ventricular outflow tachycardia ablation in a child: When electroanatomical mapping isn't good enough.

    Science.gov (United States)

    Bansal, Neha; Kobayashi, Daisuke; Karpawich, Peter P

    2017-11-11

    A 14-year-old female was referred for severe pulmonary valve insufficiency after undergoing radiofrequency ablation for a right ventricular outflow tract tachycardia that originated in the proximal pulmonary artery at 10 years of age. Clinical records indicated that ablation was guided solely by electrograms and electroanatomical mapping. Due to myocardial tissue extensions, mapping failed to identify the level of the pulmonary valve annulus, which resulted in delivery of energy on the valve proper and into the pulmonary artery. She developed severe pulmonary valve insufficiency and moderate proximal pulmonary artery stenosis necessitating intravascular stent placement 4 years later with an associated transcatheter valve. Although the nonfluoroscopic approach during ablation has gained wide acceptance for use in children, this report highlights the benefits of adjunctive imaging to identify the precise location of the pulmonary valve when ablation therapy is contemplated in the right ventricle outflow tract. © 2017 Wiley Periodicals, Inc.

  9. Volumetric real-time imaging using a CMUT ring array.

    Science.gov (United States)

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N; O'Donnell, Matthew; Sahn, David J; Khuri-Yakub, Butrus T

    2012-06-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device. This paper presents simulated and experimental imaging results for the described CMUT ring array. Three different imaging methods--flash, classic phased array (CPA), and synthetic phased array (SPA)--were used in the study. For SPA imaging, two techniques to improve the image quality--Hadamard coding and aperture weighting--were also applied. The results show that SPA with Hadamard coding and aperture weighting is a good option for ring-array imaging. Compared with CPA, it achieves better image resolution and comparable signal-to-noise ratio at a much faster image acquisition rate. Using this method, a fast frame rate of up to 463 volumes per second is achievable if limited only by the ultrasound time of flight; with the described system we reconstructed three cross-sectional images in real-time at 10 frames per second, which was limited by the computation time in synthetic beamforming.

  10. Association of A Dilated Coronary Sinus in the Fetus with Actual and Apparent Coarctation of the Aorta and Diminutive Left Heart Structures.

    Science.gov (United States)

    Ramaswamy, Prema; Rafii, Daniela; Osmolovsky, Marina; Agarwal, Arpit; Amirtharaj, Cynthia

    2016-12-01

    Evidence suggests an association between left heart obstructive lesions and dilated coronary sinus (DCS), but this has not been studied in fetuses. A retrospective review of fetal echocardiograms (FE) over an 8-year period was conducted, and patients with DCS were identified and confirmed postnatally. There were 5840 FE performed on 4920 women during this period. Of 49 patients with DCS, 22 had normal intracardiac anatomy and 27 patients had congenital heart disease (CHD) yielding an incidence of 4.6 % in the presence of CHD (27/584). Of 27 patients with DCS and CHD, approximately a third had either hypoplastic left ventricles and/or coarctations (10/27, 37 %). The incidence of left heart obstructive lesions was much higher in the presence of a DCS (37 % vs 45/557, 8 %, p < 0.0001). The odds ratio of left heart hypoplasia in fetuses with CHD and a DCS was 6.6 (95 % CI 2.8-15.3). Comparison of patients with postnatally confirmed coarctation with those with normal intracardiac anatomy with DCS, revealed that in the former, the right ventricle (p = 0.005), pulmonic valve annulus (p = 0.0001) and the tricuspid inflow were larger (p = 0.001) compared to corresponding left-sided structures. The size of the DCS was not significantly different between the two groups, but in the former, the DCS was more closely related to the posterior leaflet of the mitral valve and caused a significant diminution of the mitral inflow. Our study suggests a strong association, possibly causal, between left heart obstructive lesions and DCS in utero.

  11. A prospective study on the hemodynamic changes by intracardiac injection of contrast media

    International Nuclear Information System (INIS)

    Byun, Young Sook; Lee, Hyun; Seo, Heung Suk; Hahm, Chang Kok

    1983-01-01

    It has been known that alteration in blood pressure, heart rate and other systemic reactions can occur after introduction of contrast media into the vascular system. And the factory of these alterations are the sudden changes of the circulating blood volume, hypertonicity of the injected contrast media and adverse reactions to the contrast media. This prospective study included evaluations of the hemodynamic changes, adverse reactions and its relationship with sensitivity test and allergic history in 105 patients who had been performed angiocardiography during the period of 1 year from October, 1981 to September, 1982. The results were as follows: 1. 14 out of 105 patient showed minor reactions to contrast media such as nausea, vomiting , coughing, etc. There is no close relationship between adverse reaction and sensitivity test or previous allergic history. 2. In the group of right sided angiocardiography, 47.6% of patient showed elevation of blood pressure after injection of contrast media. 38.1% of patient, however, showed lowered blood pressure. The changes of the pulse rate were quite similar to those of blood pressure; increased in 47.7% and decreased in 40.9% of patient. 3. In the group of left sided angiocardiography, 61.6% of patient showed elevation of blood pressure immediately after injection of contrast media, and 17.5% of patient showed lowered blood pressure. 5 minutes after injection of contrast media, large group of patient showed normalized blood pressure. The pulse ratio was also increased in the 66.3% of patient

  12. Systemic Embolization from an Unusual Intracardiac Mass in the Left Ventricular Outflow Tract

    Directory of Open Access Journals (Sweden)

    Kelechukwu U. Okoro

    2017-01-01

    Full Text Available Endocarditis can affect any endocardial surface; in the vast majority of cases, the cardiac valves are involved. It is exceedingly rare to develop infective endocarditis on the endocardium of the left ventricular outflow tract due to the high velocity of blood that traverses this area. Herein, we present a rare case of left ventricular outflow tract endocarditis that likely occurred secondary to damage to the aortic valve leaflets (from healed prior aortic valve endocarditis causing a high velocity aortic valve regurgitant jet that impinged upon the interventricular septum which damaged the endocardium and resulted in a fibrotic “jet lesion.” This fibrous jet lesion served as a nidus for bacterial proliferation and vegetation formation. The high shear stress (due to high blood flow velocity through the left ventricular outflow tract likely promoted the multiple embolic events observed in this case. Our patient was successfully treated with aortic valve replacement, vegetation resection, and antibiotics.

  13. A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study

    International Nuclear Information System (INIS)

    Dharmakumar, Rohan; Plewes, Donald B; Wright, Graham A

    2005-01-01

    It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility difference with the blood of at least 34 ppm in SI units. In this work, we show through analytical approximations and numerical simulations that such a microbubble formulation can be achieved by coating typical lipid-shelled microbubbles with particles of high dipole moment. Through finite-element simulations we demonstrate that the effective volumetric magnetic susceptibility of a coated microbubble is dependent on the radius, the shell volume fraction and the magnetic susceptibility of the particulates on the shell. Our calculations suggest that a suitable microbubble formulation which will be MR-sensitive to small pressure changes at 1.5 T must be 2-3 μm in radius and be uniformly coated with single-domain magnetic nanoparticles, such as magnetite, at shell volume fractions below 5%

  14. Prenatal diagnosis of Cantrell's pentalogy with conventional and three-dimensional sonography.

    Science.gov (United States)

    León, G; Chedraui, P; San Miguel, G

    2002-09-01

    Omphaloceles and gastroschisis are the most common defects of the fetal anterior abdominal wall. The association of an omphalocele with an anterior thoracic wall defect could result from a variety of congenital syndromes of which Cantrell's pentalogy is the most common. For proper surgical scheduling of the neonate, early diagnosis of each of the components of this syndrome is important. The presence of a congenital intracardiac anomaly is the best predictor of neonatal mortality. We present a case of Cantrell's pentalogy diagnosed prenatally with conventional and three-dimensional sonographic imaging, and confirmed at birth. We discuss this case and the reports in the world literature.

  15. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  16. Canine distemper virus infection in a lesser grison (Galictis cuja: first report and virus phylogeny

    Directory of Open Access Journals (Sweden)

    Jane Megid

    2013-02-01

    Full Text Available Infectious diseases in wild animals have been increasing as a result of their habitat alterations and closer contact with domestic animals. Canine distemper virus (CDV has been reported in several species of wild carnivores, presenting a threat to wildlife conservation. We described the first case of canine distemper virus infection in lesser grison (Galictis cuja. A free-ranging individual, with no visible clinical sigs, presented sudden death after one day in captivity. Molecular diagnosis for CDV infection was performed using whole blood collected by postmortem intracardiac puncture, which resulted positive. The virus phylogeny indicated that domestic dogs were the probable source of infection.

  17. Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

    Science.gov (United States)

    Ramakrishnan, Sivasubramanian

    2015-01-01

    Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.

  18. Central nervous system systemic lupus erythematosus in children

    International Nuclear Information System (INIS)

    Osborn, A.G.; Boyer, R.S.

    1989-01-01

    Ischemic neurologic events and neuropsychiatric disorders occur in approximately 70% of patients with systematic lupus erythematosus (SLE). The CT and MR findings in adults with central nervous system (CNS) SLE have been described, but to the authors' knowledge no pediatric series has been reported. The MR and CT findings in four children with CNS SLE are compared with those reported in adults. Large infarcts are less frequent in children than in adults with CNS SLE, while multiple small infarctions and white matter lesions are more common. These findings in children who have no obvious source of emboli, intracardiac shunt, or history of trauma should raise the suspicion of SLE

  19. Implantable sensors for heart failure monitoring

    Directory of Open Access Journals (Sweden)

    P. Shasha Liu

    2013-12-01

    Implantable sensors in the CRT device offer a unique opportunity for continuous monitoring of a patient's clinical HF status by measuring cardiac rhythm, intracardiac pressures, cardiac events, and physical activity, as well as detecting any device malfunction. Detecting early signs of a deteriorating clinical condition allows prompt preemptive medical intervention to optimize HF management. As a result, not only healthcare professionals will benefit from a reduction in hospitalizations and routine in-office follow-ups, but also patients will benefit from efficient management of their HF. This review highlights the latest available device-based remote monitoring systems and the most up-to-date evidence for the use of remote monitoring in CRT.

  20. Cyanosis and Stroke due to Functional Cor Triatriatum Dexter in a Neonate.

    Science.gov (United States)

    León, Rachel L; Zaban, Nicholas B; Schamberger, Marcus S; Ho, Chang Y; Mietzsch, Ulrike

    2018-01-01

    Small remnants of the right valve of the sinus venosus are commonly found in adults, but the incidence and risk associated with these embryonic remnants in neonates are not well studied. The following report describes a cyanotic neonate with a large Eustachian valve remnant creating a functional cor triatriatum dexter who was initially diagnosed with persistent pulmonary hypertension of the newborn. The cyanosis in this infant improved over the first postnatal week with conservative management, but she suffered multifocal subcortical stroke, likely related to her intracardiac shunt. The clinical presentation and questions regarding long-term management of this rare diagnosis are explored. © 2018 S. Karger AG, Basel.

  1. Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.

    Science.gov (United States)

    Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S

    2018-04-01

    An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. One-and-a-half ventricular repair for isolated right ventricle metastatic tumor resection after lobectomy for lung cancer.

    Science.gov (United States)

    Shiose, Akira; Desai, Parag; Criner, Gerard J; Pai, Sheela; Steiner, Robert M; Kaiser, Larry R; Guy, T Sloane; Toyoda, Yoshiya

    2014-01-01

    A 77-year-old woman presented with shortness of breath 1 year after a right upper lobectomy for lung cancer. She showed a possible intracardiac metastasis on positron emission tomography scan. There was no other evidence of recurrence. The large right ventricular mass was associated with the right ventricle free wall, the apex, the papillary muscle, and the chordae to the tricuspid valve. After mass resection of the right ventricle, a one-and-a-half ventricular repair was performed with tricuspid valve replacement and defect closure. The patient was discharged on postoperative day 14 without complications and has been well for the first 3 months after the surgery.

  3. Accessory pathway location affects brain natriuretic peptide level in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Nakatani, Yosuke; Kumagai, Koji; Naito, Shigeto; Nakamura, Kohki; Minami, Kentaro; Nakano, Masahiro; Sasaki, Takehito; Kinugawa, Koichiro; Oshima, Shigeru

    2017-01-01

    The purpose of this study was to investigate the relationship between the accessory pathway location and brain natriuretic peptide (BNP) level in patients with Wolff-Parkinson-White (WPW) syndrome. We divided 102 WPW syndrome patients with normal left ventricular systolic function into four groups: those with manifest right (MR, n = 14), manifest septal (MS, n = 11), manifest left (ML, n = 30), and concealed (C, n = 47) accessory pathways. BNP level and electrophysiological properties, including difference in timing of the ventricular electrogram between the His bundle area and the distal coronary sinus area (His-CS delay), which indicate intraventricular dyssynchrony, were compared. BNP levels (pg/dl) were higher in the MR and MS groups than in the ML and C groups (MR, 64 ± 58; MS, 55 ± 45; ML, 17 ± 15; C, 25 ± 21; P syndrome patients with normal cardiac function.

  4. Dexmedetomidine Pharmacology in Neonates and Infants After Open Heart Surgery.

    Science.gov (United States)

    Su, Felice; Gastonguay, Marc R; Nicolson, Susan C; DiLiberto, MaryAnn; Ocampo-Pelland, Alanna; Zuppa, Athena F

    2016-05-01

    Dexmedetomidine is a highly selective α2-agonist with hypnotic, analgesic, and anxiolytic properties. Despite off-label administration, dexmedetomidine has found a niche in critically ill neonates and infants with congenital heart disease because of its minimal effects on respiratory function at sedative doses, facilitating early extubation and fast-track postoperative care. There are little pharmacokinetic data regarding newborns who have immature drug metabolizing capacity and who are at risk for reduced dexmedetomidine clearance and drug toxicity. The aim of this study was to determine the pharmacokinetics of dexmedetomidine in neonates and infants after open heart surgery. This study included 23 evaluable neonates (age, 1 day-1 month) and 36 evaluable infants (age, 1 month-24 months) after open heart surgery. Full-term neonates and infants requiring mechanical ventilation after open heart surgery received dexmedetomidine in a dose-escalation study. Dexmedetomidine was administered as a loading dose over 10 minutes followed by a continuous IV infusion up to 24 hours. Cohorts of 12 infants were enrolled sequentially to receive 0.35, 0.7, or 1 μg/kg dexmedetomidine followed by 0.25, 0.5, or 0.75 μg/kg/h dexmedetomidine, respectively. Cohorts of 9 neonates received 0.25, 0.35, or 0.5 μg/kg dexmedetomidine followed by 0.2, 0.3, or 0.4 μg/kg/h dexmedetomidine, respectively. Plasma dexmedetomidine concentrations were determined using a validated high-performance liquid chromatography-tandem mass spectrometry assay. A population nonlinear mixed effects modeling approach was used to characterize dexmedetomidine pharmacokinetics. Pharmacokinetic parameters of dexmedetomidine were estimated using a 2-compartment disposition model with weight allometrically scaled as a covariate on drug clearance, intercompartmental clearance, central and peripheral volume of distributions and age, total bypass time, and intracardiac shunting on clearance. Dexmedetomidine demonstrated

  5. Towards optical spectroscopic anatomical mapping (OSAM) for lesion validation in cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.

    2017-02-01

    Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.

  6. Characteristics and identification of sites of chagasic ventricular tachycardia by endocardial mapping

    Directory of Open Access Journals (Sweden)

    Távora Maria Zildany P.

    1999-01-01

    Full Text Available OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.

  7. Distribution and chronotropic effects of serotonin in the zebrafish heart.

    Science.gov (United States)

    Stoyek, Matthew R; Jonz, Michael G; Smith, Frank M; Croll, Roger P

    2017-09-01

    Several lines of evidence suggest that serotonin (5-HT) has a regulatory role in cardiovascular function from embryogenesis through adulthood. However, the reported actions of 5-HT are often contradictory and include bradycardia or tachycardia, hypotension or hypertension, and vasodilation or vasoconstriction. Clarifying such cardiac effects requires further research and may benefit from utilizing a model simpler than the mammalian hearts traditionally used in these studies. In the present study, we describe the cardiac distribution and chronotropic responses of 5-HT in the zebrafish heart. A combined anatomical, electrophysiological, and pharmacological approach was used to investigate the involvement of 5-HT pathways, and to compare neural and direct myocardial pathways of biological action. Immunohistochemical methods revealed 5-HT in endocardial cells, glial-like cells, and intracardiac neurons in the atrium. Electrocardiogram (ECG) recordings combined with the administration of pharmacological agents demonstrated that 5-HT acted predominantly through direct myocardial pathways resulting in a reduction of heart rate. Overall, the results of this study contribute significant advances in the establishment of the zebrafish as a new model for studies of the role of 5-HT in autonomic cardiac control. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Imaging in percutaneous ablation for atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica [Erasmus Medical Center, Department of Radiology, GD Rotterdam (Netherlands); Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia); Dill, Thorsten [Kerckhoff-Heart Center, Department of Cardiology, Bad Nauheim (Germany); Ristic, Arsen D.; Seferovic, Petar M. [Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia)

    2006-11-15

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  9. Imaging in percutaneous ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Dill, Thorsten; Ristic, Arsen D.; Seferovic, Petar M.

    2006-01-01

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  10. COMPORTAMIENTO ANTIARRÍTMICO DE LA HIPOXIA EN SIMULACIONES DE PARED TRANSMURAL CARDÍACA EN PRESENCIA DE ISQUEMIA SUB-EPICÁRDICA

    Directory of Open Access Journals (Sweden)

    Oscar Henao Gallo

    2011-01-01

    of simulations show hypoxic activation anti-arrhythmic behavior. Hiperkalemia is the main agent able to block heart conduction, TQ segment and ST segment alterations of calculated electrograms

     

    Keywords: Electrograms, heterogeneous transmural wall, hypoxia, ischemia, Luo-Rudy model, polymorphic ventricular tachycardia, spiral reentry


  11. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. A Rare Cause of Abdominal Pain in Childhood: Cardiac Angiosarcoma

    Directory of Open Access Journals (Sweden)

    Elvan Caglar Citak

    Full Text Available Abstract Cardiac angiosarcomas are extremely rare in childhood, they are rapidly progressive tumours that often present themselves as diagnostic dilemmas, resulting in delayed diagnosis. Also, extracardiac manifestations, including abdominal pain, are extremely rare in patients with intracardiac tumors. We herein present the case of a 15-year-old girl who presented with abdominal pain. Echocardiography and thoracic computed tomography showed right atrial mass. The patient underwent surgery, chemotherapy, and radiotherapy. Eight months after treatment, abdominal recurrence was detected. The abdominal mass was resected, and radiotherapy and new chemotherapy protocol were given. The present case illustrates a rare case of primary cardiac angiosarcoma posing a diagnostic dilemma in an adolescent girl.

  13. MR imaging of the heart: functional imaging

    International Nuclear Information System (INIS)

    Croisille, P.; Revel, D.

    2000-01-01

    To date, most applications of cardiovascular MRI relate to the evaluation of major vessels rather than the heart itself. However, MRI plays a major role in the evaluation of specific types of cardiovascular pathology, namely intracardiac and paracardiac masses, pericardial disease, and congenital heart disease. In addition, because the visualization of cardiovascular anatomy with MR is non-invasive and permits three-dimensional analysis but also allows functional assessment of the cardiac pump, it is clear that MRI will have a growing and significant impact over the next years. We review some of the technical aspect of cardiac MRI and describe the current and potential clinical and investigative applications of this new methodology. (orig.)

  14. In vitro and in vivo studies of pulmonary artery flow

    International Nuclear Information System (INIS)

    Sahn, D.J.; Yoganathan, A.P.

    1986-01-01

    A variety of interesting intracardiac flow patterns have been recorded by pulsed and continuous wave Doppler technologies in humans with heart disease. Some of these patterns have, in fact, been difficult to explain and are now more easily understood using color Doppler flow mapping systems which show the spatial location of flow. The authors performed a number of studies in patients, as well as studies in in vitro systems to model some of the phenomenon that the authors observed in the pulmonary artery. Their studies with Doppler flow mapping in the clinical situation, in the in vitro model, and in the animal models of congenital heart disorders lend insights into the complex hydrodynamics present in the pulmonary artery

  15. Dilemma in clinical diagnosis of right ventricular masses.

    Science.gov (United States)

    Sušić, Livija; Baraban, Vedrana; Vincelj, Josip; Maričić, Lana; Ćatić, Jasmina; Blažeković, Robert; Manojlović, Spomenka

    2017-07-08

    Detection of an intracardiac mass always represents a clinical challenge. We present a 61-year-old female patient with symptoms of New York Heart Association class III. Two-dimensional transthoracic echocardiography revealed a hypoechogenic mass in the cavity of the dilated right ventricle (RV). Cardiac MRI described a pathologic structure of the RV free wall with pedunculated tumor in its cavity. Three months later, on a repeated echocardiography, there were three individual masses. The patient underwent surgery and the pathohistologic report demonstrated thrombotic masses. During the postoperative period, after reviewing all medical records, the conclusion was arrhythmogenic RV cardiomyopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:362-369, 2017. © 2016 Wiley Periodicals, Inc.

  16. [Traumatic tricuspid insufficiency. Apropos of 2 cases].

    Science.gov (United States)

    Ventre, F; Bertinchant, J P; Noblet, D; Frapier, J M; Carabasse, D; Nigond, J; Ledermann, B; Cohen, S; Joubert, P; Grolleau-Raoux, R

    1995-06-01

    The authors report two cases of tricuspid regurgitation by a ruptured anterior papillary muscle secondary to non-penetrating thoracic trauma. In the presence of suggestive clinical and electrocardiographic abnormalities (systolic murmur, right heart failure, right bundle branch block), echocardiography confirmed the tricuspid regurgitation, showed its mechanism and excluded any other intracardiac lesions. Tricuspid annuloplasty was performed in both cases because of the persistence of failure or degradation of the patient's clinical condition. Peroperative echocardiography was used to judge the quality of the surgical repair in both cases. Traumatic tricuspid regurgitation is a rare condition and the diagnosis is often delayed. Echocardiography is the investigation of choice and guides treatment which is essentially valvular repair in symptomatic patients.

  17. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  18. Adult brain abscess associated with patent foramen ovale: a case report

    Directory of Open Access Journals (Sweden)

    Stathopoulos Georgios T

    2007-08-01

    Full Text Available Abstract Brain abscess results from local or metastatic septic spread to the brain. The primary infectious site is often undetected, more commonly so when it is distant. Unlike pediatric congenital heart disease, minor intracardiac right-to-left shunting due to patent foramen ovale has not been appreciated as a cause of brain abscess in adults. Here we present a case of brain abscess associated with a patent foramen ovale in a 53-year old man with dental-gingival sepsis treated in the intensive care unit. Based on this case and the relevant literature we suggest a link between a silent patent foramen ovale, paradoxic pathogen dissemination to the brain, and development of brain abscess.

  19. Inflammatory Pseudotumor Originating from the Right Ventricular Outflow Tract

    Directory of Open Access Journals (Sweden)

    Mohita Singh

    2016-01-01

    Full Text Available Introduction. Inflammatory pseudotumor is an uncommon entity, and its cardiac origin is exceedingly rare. Case History. A previously healthy 27-year-old man was found to have a systolic murmur during preemployment screening evaluation. A transthoracic echocardiogram revealed a 4 × 2.5 cm mass originating from the right ventricle (RV outflow tract extending into the aortic root. A computed tomography guided biopsy confirmed an IgG4-related inflammatory pseudotumor. Patient was started on oral prednisone with subsequent reduction in mass size. Conclusion. Cardiac inflammatory pseudotumors are markedly rare tumors that should be considered in the differential of intracardiac tumors which otherwise includes cardiac fibromas, myxomas, and sarcomas.

  20. The challenge of staphylococcal pacemaker endocarditis in a patient with transposition of the great arteries endocarditis in congenital heart disease

    International Nuclear Information System (INIS)

    Ch'ng, Julie; Chan, William; Lee, Paul; Joshi, Subodh; Grigg, Leanne E.; Ajani, Andrew E.

    2003-01-01

    Staphylococcus aureus is a leading cause of septicaemia and infective endocarditis. The overall incidence of staphylococcal bacteraemia is increasing, contributing to 16% of all hospital-acquired bacteraemias. The use of cardiac pacemakers has revolutionized the management of rhythm disturbances, yet this has also resulted in a group of patients at risk of pacemaker lead endocarditis and seeding in the range of 1% to 7%. We describe a 26-year-old man with transposition of the great arteries who had a pacemaker implanted and presented with S. aureus septicaemia 2 years postpacemaker implantation and went on to develop pacemaker lead endocarditis. This report illustrates the risk of endocarditis in the population with congenital heart disease and an intracardiac device

  1. Lyme carditis. Electrophysiologic and histopathologic study

    International Nuclear Information System (INIS)

    Reznick, J.W.; Braunstein, D.B.; Walsh, R.L.; Smith, C.R.; Wolfson, P.M.; Gierke, L.W.; Gorelkin, L.; Chandler, F.W.

    1986-01-01

    To further define the nature of Lyme carditis, electrophysiologic study and endomyocardial biopsy were performed in a patient with Lyme disease, whose principal cardiac manifestation was high-degree atrioventricular block. Intracardiac recording demonstrated supra-Hisian block and complete absence of an escape mechanism. Gallium 67 scanning demonstrated myocardial uptake, and right ventricular endomyocardial biopsy revealed active lymphocytic myocarditis. A structure compatible with a spirochetal organism was demonstrated in one biopsy specimen. It is concluded that Lyme disease can produce active myocarditis, as suggested by gallium 67 imaging and confirmed by endomyocardial biopsy. Furthermore, the presence of high-grade atrioventricular block in this disease requires aggressive management with temporary pacemaker and corticosteroid therapy

  2. Morphological evaluation of complex congenital heart disease by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takahashi, Osahiro

    1993-01-01

    Ninety infants and children with complex congenital heart disease were examined with magnetic resonance imaging and the accuracy of morphological diagnoses by MRI was tested by comparison to the final diagnoses primarily based on angiocardiography. The sensitivity and specificity of MRI diagnoses were generally excellent in evaluating vena caval and atrial morphology, type of AV connection, ventricular morphology, type of VA connection and great vessel morphology. Although some difficulty with evaluating the detailed anatomy of the AV valve and its suspension system and fine vascular structures, MRI could demonstrate the entire cardiac structures clearly and provide the 3-dimensional information regarding the intracardiac structures, and it was extremely valuable in morphological assessment of complex congenital heart disease. (author)

  3. Optimization of special heart disease diagnosis by combined computerized tomography, echocardiography and intracardiac scintiscanning

    International Nuclear Information System (INIS)

    Freitag, J.; Schmidt, H.; Otto, H.J.; Punrich, R.; Gunkel, H.; Mann, D.; Freitag, G.; Waigand, J.; Eger, H.; Zentralklinik fuer Herz- u. Lungenkrankheiten, Bad Berka; Akademie der Wissenschaften der DDR, Berlin-Buch. Zentralinstitut fuer Herz-Kreislaufforschung)

    1986-01-01

    Cardiac computer tomography, echocardiography and radionuclide heart diagnosis are growing more and more important in cardiologic diagnostics. The value of the procedures was tested in 74 patients by combined application. Concordant morphologic findings could be obtained with echocardiography and cardiac computer tomography in the cases of chronic ischemic heart disease, cardiomyopathy and valvular heart diseases. Localized kinetic disturbances could be registered echocardiographically and by scintiscanning. The passableness of an aortocoronary bypass can be controlled first of all non-invasively by cardiac computer tomography. (author)

  4. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    Science.gov (United States)

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged

  5. Effect of blood collection technique in mice on clinical pathology parameters.

    Science.gov (United States)

    Schnell, Michael A; Hardy, Christine; Hawley, Melanie; Propert, Kathleen Joy; Wilson, James M

    2002-01-01

    A study was conducted in normal healthy C57BL/6 mice to determine the effect of method of blood collection on clinical pathology parameters and to provide value ranges for these parameters. Males and females were used and were randomly assigned to treatment groups based upon phlebotomy method. The blood was collected using one of four methods: intracardiac (IC), a single attempt at collection from the caudal vena cava (VC), collection from the caudal vena cava with collection of any extravasated blood from the peritoneum (MC), or retroorbital phlebotomy (RO). Evaluation of blood and serum samples was conducted for a number of serum biochemistries including liver function tests and complete blood count with differentials and platelet counts. Female mice demonstrated higher values for red blood cell number, hemoglobin (p values for platelet counts, specific white blood cell numbers (total, neutrophil, lymphocyte, and eosinophil counts), globulin, amylase, and the BUN/creatinine ratio. Overall, the VC method was associated with the least variation in both sexes and appeared slightly better than the IC method for the parameters evaluated. The largest difference between groups was noted for the transaminase levels. While alanine aminotransferase (ALT) values were similar between the IC and VC groups, aspartate aminotransferase (AST) values were associated with less variation for the VC method. Transaminase levels for the MC and RO groups were associated with relatively large ranges and variation. ALT results from the RO method, the only method amenable to repetitive sample collection used in this evaluation, indicate that this is an acceptable method. The results demonstrate the substantial impact that phlebotomy method has on the assay results and that the VC or IC methods provide the most consistent results. The ranges by collection method and sex provided here can be used to select the preferred method of collection when designing a study and for comparison of data

  6. Changes in the spectral composition of animal-brain electrical activity under the influence of nonthermal millimeter-wave radiation on acupuncture points

    Energy Technology Data Exchange (ETDEWEB)

    Khramov, R.N.; Vorob`ev, V.V.

    1994-07-01

    The frequency spectra (0-26 Hz) of electrograms (EG) of the preoptic region of the hypothalamus were studied in chronic experiments on nine awake rabbits under the influence of nonthermal millimeter-bank (55-75 GHz) electromagnetic fields on various acupuncture points: (I) the auricular {open_quotes}heart{close_quotes} point (after F. G. Portnov); (II) the cranial acupoint (TR-20; the {open_quotes}hypothalamus{close_quotes} point after R. Voll); and (III) the {open_quotes}longevity{close_quotes} acupoint (E-36). Irradiation of point I was accompanied by significant suppression of hypothalamic electrical activity at 5 and 16 Hz and enhancement at 7-8, 12, and 26 Hz. Irradiation of point II, and III were, respectively, 31%, 21%, and 5% (p < 0.05, U-criterion). These results suggest that acupuncture points I and II are more sensitive to millimeter-band radiation than is point III. The presence of individual characteristics of the effects and their change after stress to sign inversion were shown in rat experiments in which the acupuncture points were irradiated.

  7. Development of MATLAB software to control data acquisition from a multichannel systems multi-electrode array.

    Science.gov (United States)

    Messier, Erik

    2016-08-01

    A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.

  8. Long-term biatrial recordings in post-operative atrial fibrillation.

    Science.gov (United States)

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  9. Evaluation of OCT on retinopathy induced by tunicamycin in rats

    Directory of Open Access Journals (Sweden)

    Bo-Yi Zhang

    2017-07-01

    Full Text Available AIM:To evaluate the morphological and functional changes of retinas induced by treatment of tunicamycin with optical coherence tomography(OCTin rats. METHODS:Totally 60 SD rats were randomly divided into 3 groups(20 in each group, 0.5mg/kg(in low dose group, 1.5mg/kg(in high dose grouptunicamycin were injected into vitreous cavity and saline(9g/L NaClwere injected in the same dose as a control group. Changes of retinas were observed by OCT on the 1,7 and 14d after treatment of tunicamycin. Then the rats were sacrificed, retinas were taken out and embedded by the paraffin, tissue sections and the HE staining were performed. RESULTS:OCT results suggested that tunicamycin played damage effects on retinal morphology and structure which appeared a time- and dose- dependent. Fundus photography results suggested that 2wk after tunicamycin treatments, with the gradually changing of tunicamycin concentration, peripheral retinal and macular region became pale color gradually, edema occurred in optic disk, retinal vessels appeared thinner in the high dose group, optic nerve came out atrophy. Fluorescein angiography confirmed that tunicamycin injection in vitreous cavity 2wk later, retinal vessels injury occurred, resulted in leaking of intravascular contrast agent from peripheral to the central part of the retinas. Electrophysiological data showed that retinal electrogram occurred disorder induced by tunicamycin, such as the amplitude of a wave, b wave decreased gradually, even closed to zero, which was very different from control significantly(PCONCLUSION: Clinical retinal diseases could be simulated by retinal damage animal model induced by tunicamycin treatment. OCT detection offered real-time images of the retinal cross-section, which provided a helpful non-invasive method for detecting and evaluating the retinal damages.

  10. Dysfunction of Right Heart in Attack Period of Bronchial Asthma in Children

    Directory of Open Access Journals (Sweden)

    V.А. Kondratiev

    2015-11-01

    Full Text Available There were performed Doppler echocardiography investigations of functional state of the right heart in 42 children aged 5–17 years old in attack period of bronchial asthma of moderate to severe degree. Changes of intra-cardiac hemodynamics of the right heart in children in attack period of bronchial asthma were characterized by disturbance of systolic and diastolic function of the right ventricle and right atrium. Combined systolic-diastolic variant of the right ventricle dysfunction was typical for attack period of bronchial asthma in children and developed in 95.5 % of cases. Elevation of pressure in pulmonary artery was typical and significantly more often occurred in severe asthma attack, herewith pulmonary hypertension of the second degree predominated.

  11. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  12. Higher levels of serum fibrin-monomer reflect hypercoagulable state and thrombus formation in the left atrial appendage in patients with acute ischemic stroke.

    Science.gov (United States)

    Okuyama, Hidenobu; Hirono, Osamu; Liu, Ling; Takeishi, Yasuchika; Kayama, Takamasa; Kubota, Isao

    2006-08-01

    It is sometimes difficult to make a diagnosis of cardioembolic stroke in the stroke care unit, because of the splashing and vanishing of the intracardiac source of the emboli on transesophageal echocardiography. Serum fibrin-monomer (FM) is a new marker for coagulation activity that is useful for identifying older individuals at increased risk of ischemic stroke. Two hundred and four patients with acute ischemic stroke were examined for serum coagulation and fibrinolytic activity on admission, and underwent transesophageal echocardiography within 7 days of onset. Serum levels of FM was significantly higher in patients with left atrial appendage (LAA) thrombus formation (n=24) than in those with no thrombus (88+/-52 vs 14+/-9 microg/ml, pvs 8+/-5 microg/ml, pstroke.

  13. Synthesis of results of randomized controlled trials of contrast media

    International Nuclear Information System (INIS)

    Kinnison, M.L.; Powe, N.R.; Steinberg, E.P.

    1988-01-01

    The authors review 100 randomized controlled trials (RCTs) that examine the safety or efficacy of new low-osmolality contrast media (LOM) and focus on the 43 RCTs judged to be of the highest quality. These RCTs showed no consistent differences in nephrotoxicity between high- and low-osmolality contrast media. Certain cardiovascular parameters were altered less with low-osmolality agents during intracardiac injection, but the clinical significance of these differences in unclear. Heat and pain sensations occurred less often with low-osmolality contrast media. No differences were noted in the incidence of nausea, vomiting, urticaria, or bronchospasm. Even with numerous RCTs comparing these media, physicians still must make economically significant choices about contrast media without sufficient data about their relative safety

  14. Late Thrombolytic Treatment In A Patient With Ischemic Stroke Caused By Biatrial Thrombus

    Directory of Open Access Journals (Sweden)

    Halit CINARKA

    2015-07-01

    Full Text Available Venous thromboembolism is a preventable disease when necessary precautions are taken and it occurs along with deep vein thrombosis and pulmonary embolism. Mortality related to venous thromboembolism may be high in the acute phase of the disease and it may become chronic. Intracardiac thrombus may be detected in some venous thromboemboli cases. Cardiac embolism is responsible for most of the ischemic strokes which can be very mortal or may cause serious morbidity when they are not treated in time. In this report, we aimed to present the results of late antithrombolytic treatment in a 77-year old patient who developed deep vein thrombosis, biatrial thrombosis and ischemic stroke following hydrocephalus shunt operation.   Key words: Venous thromboembolism; ischemic stroke; thrombolytic therapy

  15. Nerve endings in the heart of teleosts.

    Science.gov (United States)

    Kumar, S

    1979-01-01

    The nerve endings in the heart of fishes were studied using silver impregnation techniques. The heart chambers are profusely innervated by the sympathetic, parasympathetic (vagal) and postganglionic fibers of the intracardiac ganglia situated at the sinuatrial and the atrioventricular junctions. The plexuses are composed of medullated and nonmedullated fibers. The nerve fibers generally end freely and are slightly branched or unbranched terminations of myelinated and unmyelinated fibers. Moreover, a few nerve fibers end redundant in the form of end-rings, bulb-like, bush-like, club-shaped end end-coil like structures. The complex unencapsulated types of endings are also found in the myocardium of the atrium and the ventricle. The encapsulated endings (Vater-Pacinian; Krause end-bulb) could not be observed.

  16. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  17. COMPARATIVE EFFECTS OF MONOTHERAPY WITH MAGNESIUM AND COMBINED THERAPY WITH MAGNESIUM AND Β-BLOCKER ON PRIMARY MITRAL VALVE PROLAPSE WITH HEART RHYTHM DISORDERS

    Directory of Open Access Journals (Sweden)

    E. G. Nurtdinova

    2007-01-01

    Full Text Available Aim. To compare effects of monotherapy with magnesium and combined therapy with magnesium and β-blocker on primary mitral valve prolapse (MVP with heart rhythm disorders.Material and methods. 71 patients with primary MVP 1-2 degree and heart rhythm disorders were involved in the study. The patients were split into three groups. Group I (25 persons received monotherapy with magnesium orotate at a dose of 1-3 g per day; group II (28 persons received combined therapy with magnesium orotate and betaxolol. The control group (18 persons received no therapy. Initially and after 12 weeks of observation all the patients underwent electrocardiography (ECG, ECG-Holter monitoring, echocardiography and autonomic balance assessment by A.M. Vein’s questionnaire.Results. In 12 weeks of treatment groups I and II showed positive dynamics in the MVP manifestations, including significant reduction in severity of the autonomic dysfunction syndrome, ECG positive dynamics, antiarrhythmic effect, decrease in the degree of prolapse, diminution of mitral regurgitation and left auricle volumes. More substantial hemodynamic effects were found in the group of patients who received combination therapy.Conclusion. Combined therapy has proven advantages in comparison with magnesium monotherapy in terms of daily quantity of extrasystoles, reduction in heart rate, decrease in autonomic disfunction and normalization of intracardiac hemodynamics.

  18. COMPARATIVE EFFECTS OF MONOTHERAPY WITH MAGNESIUM AND COMBINED THERAPY WITH MAGNESIUM AND Β-BLOCKER ON PRIMARY MITRAL VALVE PROLAPSE WITH HEART RHYTHM DISORDERS

    Directory of Open Access Journals (Sweden)

    E. G. Nurtdinova

    2015-12-01

    Full Text Available Aim. To compare effects of monotherapy with magnesium and combined therapy with magnesium and β-blocker on primary mitral valve prolapse (MVP with heart rhythm disorders.Material and methods. 71 patients with primary MVP 1-2 degree and heart rhythm disorders were involved in the study. The patients were split into three groups. Group I (25 persons received monotherapy with magnesium orotate at a dose of 1-3 g per day; group II (28 persons received combined therapy with magnesium orotate and betaxolol. The control group (18 persons received no therapy. Initially and after 12 weeks of observation all the patients underwent electrocardiography (ECG, ECG-Holter monitoring, echocardiography and autonomic balance assessment by A.M. Vein’s questionnaire.Results. In 12 weeks of treatment groups I and II showed positive dynamics in the MVP manifestations, including significant reduction in severity of the autonomic dysfunction syndrome, ECG positive dynamics, antiarrhythmic effect, decrease in the degree of prolapse, diminution of mitral regurgitation and left auricle volumes. More substantial hemodynamic effects were found in the group of patients who received combination therapy.Conclusion. Combined therapy has proven advantages in comparison with magnesium monotherapy in terms of daily quantity of extrasystoles, reduction in heart rate, decrease in autonomic disfunction and normalization of intracardiac hemodynamics.

  19. Growth Status of Iranian Children with Hemodynamically Important Congenital Heart Disease

    Directory of Open Access Journals (Sweden)

    Mohammad Dalili

    2011-02-01

    Full Text Available The relationship between congenital heart disease (CHD and growth retardation is well documented. We investigated the growth condition of Iranian children with several types of congenital heart disease (CHD and compared it with worldwide researches. Growth condition was investigated in 469 patients with important CHD aged from 1 month to 18 years. The patients were divided into two groups; infants (aged 12 months or less, and children (1-18 yrs of age. Children with hemodynamically unimportant small VSDs or small ASDs were not studied. Other exclusion criteria were prematurity, known genetic disorders and neurologic disease affecting growthd. All patients' cardiac diagnoses were made on the basis of clinical and laboratory examinations; including electrocardiography, echocardiography, cardiac catheterization, and angiography. Body weight and height of all patients were measured using conventional methods and compared with standard growth charts. In all patients body weights and heights were significantly lower than normal population. This difference was greater in the weight of female children. Other risk factors for growth failure were large left-to-right intracardiac shunts, pulmonary hypertension and cyanosis. Iranian children with CHD have growth failure somewhat different from other countries. Lower body weights of cyanotic patients and female children indicated that these patients need more nutritional and psychosocial attention.

  20. Changes in the lipid composition of blood under the influence of a single submaximal exercise capacity (experimental research.

    Directory of Open Access Journals (Sweden)

    Ermolaeva E.N.

    2015-06-01

    Full Text Available In acute physical exercise, there is a change in oxygen delivery working tissues, blood gas transport function and efficiency of the use of oxygen by cells in the process of metabolism, which is the basis for compensation for physical activities. Lipid metabolism plays an important role in the energy supply of muscle activity. The aim of our research is to study the effect of a single submaximal exercise capacity by changing the lipid profile of peripheral blood. Materials and Methods. The study was performed on 18 white rats. Model of acute exercise: animals swam 4 minutes with a load weighing 20% of body weight. Blood sampling was performed by intracardiac way, right after exercise. The blood lipid profile was determined. Results. In the experiment reported an increase in triglycerides, total cholesterol, very low-density lipoproteins, but the atherogenic ratio is maintained at the control values, due to a significant increase in the level of high-density lipoprotein. Conclusion. Acute submaximal exercise capacity by untrained body has an atherogenic effect. Working muscles during physical activity is a major consumer of free fatty acids, which are the source of atherogenic lipoprotein form of the very low and low density.

  1. Patent foramen ovale and cryptogenic stroke. Echocardiography role and state of the art

    International Nuclear Information System (INIS)

    Jaramillo U, Mario H

    2008-01-01

    The causes of ischemic stroke in young patients are difficult to find, in spite of systematic investigations directed to rule out heart etiology, alterations in coagulation or any other type of vascular disease; hence the cryptogenic definition. There have been speculations regarding the potential role of right-to-left intracardiac shunts as a path for paradoxical embolisms that result in ischemic cerebral disease. Transesophagic echocardiography with peripheral venous injection of saline contrast has shown to be the preferred method for the diagnosis of patent foramen ovale and right-to-left shunt. Prospective studies using acetylsalicylic acid or warfarin have not shown significant reduction of recurrent strokes. Even though both surgical and percutaneous closure of the patent foramen ovale have shown to decrease the rate of subsequent embolic episodes, their indication remains under discussion, at least until the appearance of randomized clinical trials, now under development. However, the cases of recurrent paradoxical embolism and those in professional scuba divers, both with intra-atrial septum aneurysm and an associated patent foramen ovale, are the only unequivocal indications for percutaneous closure. Successful closure, defined by transesophagic echocardiography, seems to predict lack of recurrent embolic events. As the complication rate of device implantation may decrease and these devices become technologically simple, percutaneous closure will prevail over surgical closure

  2. From 4D Medical Images (CT, MRI, and Ultrasound to 4D Structured Mesh Models of the Left Ventricular Endocardium for Patient-Specific Simulations

    Directory of Open Access Journals (Sweden)

    Federico Canè

    2018-01-01

    Full Text Available With cardiovascular disease (CVD remaining the primary cause of death worldwide, early detection of CVDs becomes essential. The intracardiac flow is an important component of ventricular function, motion kinetics, wash-out of ventricular chambers, and ventricular energetics. Coupling between Computational Fluid Dynamics (CFD simulations and medical images can play a fundamental role in terms of patient-specific diagnostic tools. From a technical perspective, CFD simulations with moving boundaries could easily lead to negative volumes errors and the sudden failure of the simulation. The generation of high-quality 4D meshes (3D in space + time with 1-to-1 vertex becomes essential to perform a CFD simulation with moving boundaries. In this context, we developed a semiautomatic morphing tool able to create 4D high-quality structured meshes starting from a segmented 4D dataset. To prove the versatility and efficiency, the method was tested on three different 4D datasets (Ultrasound, MRI, and CT by evaluating the quality and accuracy of the resulting 4D meshes. Furthermore, an estimation of some physiological quantities is accomplished for the 4D CT reconstruction. Future research will aim at extending the region of interest, further automation of the meshing algorithm, and generating structured hexahedral mesh models both for the blood and myocardial volume.

  3. Surgical Treatment of Primary Intracardiac Myxoma: 20-Year Experience in “Shahid Modarres Hospital”—A Tertiary University Hospital—Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Zahra Ansari Aval

    2015-01-01

    Full Text Available Although cardiac tumors are not common they may vary in terms of race and surgical approach in different countries. Method. Patients data of 20 years was collected and evaluated in the “Shahid Modarres Hospital”—a tertiary university hospital—Tehran, Iran. Results. 42 patients with cardiac myxoma (all cases in 20 years were included in study, 17 males and 25 females, age difference: 13 to 76 years (mean 50.6. Most of patients were in functional classes I, II. 35 patients complained of dyspnea and 3 patients had embolic events. 97.6% of tumors were primary (41 patients and one tumor was recurrent (2.4%, 85.7% of tumors (36 cases were located in LA, and 88.1% of tumors (37 cases were pediculated. 40 patients (95% had one tumor. In 22 patients (52.3% after tumor resection septal defects were repaired primarily while in 18 patients (42.8% the defects were repaired with pericardial patch and In one patient, tumor resected without any septal defect. Mean tumor size was about 5.22 cm (range of 2.2 to 8.2 cm. Postoperatively, 33 patients discharged from hospital without any complication. Discussion. The research reveals that patients’ age and gender were similar to that of other studies in other countries while tumor’s incidence seems to be higher. 3 patients were diagnosed after remote embolic event and one patient was diagnosed after MI reflecting relatively high tumor complications and late diagnosis. Conclusion. In our study mean time from diagnosis to operation was too long. The patients had more preoperative embolic events and complication. However, size of myxoma and location of that was as same as its rate in the other literature. As recommendation we suggested that in all patients with vague chest pain or remote embolic events cardiac myxomas should be ruled out.

  4. A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF)

    DEFF Research Database (Denmark)

    Hasenfuß, Gerd; Hayward, Chris; Burkhoff, Dan

    2016-01-01

    BACKGROUND: Heart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, espec...

  5. Total Artificial Heart Bridge to Transplantation for a Patient With Occult Intracardiac Malignancy: Case Report.

    Science.gov (United States)

    Reich, H; Czer, L; Bannykh, S; De Robertis, M; Wolin, E; Amersi, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-09-01

    Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Percutaneous closure of patent foramen ovale and atrial septal defect in adults: the impact of clinical variables and hospital procedure volume on in-hospital adverse events.

    Science.gov (United States)

    Opotowsky, Alexander R; Landzberg, Michael J; Kimmel, Stephen E; Webb, Gary D

    2009-05-01

    Percutaneous closure of patent foramen ovale/atrial septal defect (PFO/ASD) is an increasingly common procedure perceived as having minimal risk. There are no population-based estimates of in-hospital adverse event rates of percutaneous PFO/ASD closure. We used nationally representative data from the 2001-2005 Nationwide Inpatient Sample to identify patients >or-=20 years old admitted to an acute care hospital with an International Classification of Diseases, Ninth Revision code designating percutaneous PFO/ASD closure on the first or second hospital day. Variables analyzed included age, sex, number of comorbidities, year, same-day use of intracardiac or other echocardiography, same-day left heart catheterization, hospital size and teaching status, PFO/ASD procedural volume, and coronary intervention volume. Outcomes of interest included length of stay, charges, and adverse events. The study included 2,555 (weighted to United States population: 12,544 +/- 1,987) PFO/ASD closure procedures. Mean age was 52.0 +/- 0.4 years, and 57.3% +/- 1.0% were women. Annual hospital volume averaged 40.8 +/- 7.7 procedures (range, 1-114). Overall, 8.2 +/- 0.8% of admissions involved an adverse event. Older patients and those with comorbidities were more likely to sustain adverse events. Use of intracardiac echocardiography was associated with fewer adverse events. The risk of adverse events was inversely proportional to annual hospital volume (odds ratio [OR] 0.91, 95% confidence interval [CI] 0.86-0.96, per 10 procedures), even after limiting the analysis to hospitals performing >or=10 procedures annually (OR 0.91, 95% CI 0.85-0.98). Adverse events were more frequent at hospitals in the lowest volume quintile as compared with the highest volume quintile (13.3% vs 5.4%, OR 2.42, 95% CI 1.55-3.78). The risk of adverse events of percutaneous PFO/ASD closure is inversely correlated with hospital volume. This relationship applies even to hospitals meeting the current guidelines

  7. Scintigraphic detection of thrombi using indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Ikeoka, Kiyomitsu; Todo, Yasuhiro; Konishiike, Atsushi; Fujisue, Ryu; Ohyanagi, Mitsumasa; Yasutomi, Nagao; Tanimoto, Masaho; Kawai, Yoshitaka; Iwasaki, Tadaaki

    1985-01-01

    Intracardiac and arterial thrombi were examined by scintigraphy using In-111-oxine labeled autologous platelets. 1. In 22 cases of myocardial infarction including six with ventricular aneurysms, four had positive findings of thrombi on imaging and detected also by echocardiography. All four had ventricular aneurysms. The so-called ''moya-moya'' echoes (fuzzy echoes) were demonstrated in two of these four cases. 2. We encountered two cases with positive findings on imaging in 13 with mitral valve disease. These two had systemic embolic episodes after scintigraphic examination. ''Moya-moya'' echoes were detected in the left atrial cavity in four with negative findings on imaging. 3. Positive images were obtained in two of three with acute arterial occlusive disease, and in both cases platelet deposition was observed in the proximal site of obstruction. Though thrombectomy was performed for one of these two cases, no thrombus was detected at the site of platelet deposition. After one month, re-examination revealed only negative findings in all sites in both these patients. 4. In the six cases of aortic aneurysm, three had platelet deposition within their aneurysms, and surgery was performed for these positive cases, but one of them had no thrombus. 5. Positive images were obtained in only one of seven patients with chronic arterial occlusive disease. 6. Coagulation tests and platelet studies were investigated for patients with positive or negative platelet scans. Only the data of the thrombo-test showed a significant difference (97 +- 9 % vs 23 +- 7 %, p < 0.001). Three cases of positive imaging became negative after anticoagulant therapy. 7. We tried ECT for eight cases 24 hours after injection of In-111-oxine labeled platelets. Three cases showed clear images of thrombi, while the planar images could not detect them at an early stage. Therefore, we propose that ECT can be a useful technique for diagnosing intracardiac thrombi in early stage. (author)

  8. Adrenergic stimulation promotes T-wave alternans and arrhythmia inducibility in a TNF-alpha genetic mouse model of congestive heart failure.

    Science.gov (United States)

    Shusterman, Vladimir; McTiernan, Charles F; Goldberg, Anna; Saba, Samir; Salama, Guy; London, Barry

    2010-02-01

    T-wave alternans (TWA) is a proarrhythmic repolarization instability that is common in congestive heart failure (CHF). Although transgenic mice are commonly used to study the mechanisms of arrhythmogenesis in CHF, little is known about the dynamics of TWA in these species. We hypothesized that TWA is present in a TNF-alpha model of CHF and can be further promoted by adrenergic stimulation. We studied 16 TNF-alpha mice and 12 FVB controls using 1) in vivo intracardiac electrophysiological testing and 2) ambulatory telemetry during 30 min before and after an intraperitoneal injection of isoproterenol. TWA was examined using both linear and nonlinear filtering applied in the time domain. In addition, changes in the mean amplitude of the T wave and area under the T wave were computed. During intracardiac electrophysiological testing, none of the animals had TWA or inducible arrhythmias before the injection of isoproterenol. After the injection, sustained TWA and inducible ventricular tachyarrhythmias were observed in TNF-alpha mice but not in FVB mice. In ambulatory telemetry, before the isoproterenol injection, the cardiac cycle length (CL) was longer in TNF-alpha mice than in FVB mice (98 +/- 9 and 88 +/- 3 ms, P = 0.04). After the injection of isoproterenol, the CL became 8% and 6% shorter in TNF-alpha and FVB mice (P mice, the magnitude of TWA was 1.5-2 times greater than in FVB mice both before and after the isoproterenol injection. The magnitude of TWA increased significantly after the isoproterenol injection compared with the baseline in TNF-alpha mice (P = 0.003) but not in FVB mice. The mean amplitude of the T wave and area under the T wave increased 60% and 80% in FVB mice (P = 0.006 and 0.009) but not in TNF-alpha mice. In conclusion, TWA is present in a TNF-alpha model of CHF and can be further promoted by adrenergic stimulation, along with the enhanced susceptibility for ventricular arrhythmias.

  9. Fatal air embolism during endoscopic retrograde cholangiopancreatography (ERCP): An 'impossible' diagnosis for the forensic pathologist.

    Science.gov (United States)

    Marchesi, Matteo; Battistini, Alessio; Pellegrinelli, Moira; Gentile, Guendalina; Zoja, Riccardo

    2016-01-01

    Fatal air embolism related to endoscopic retrograde cholangiopancreatography is a very rare phenomenon. The authors describe the case of a 51-year-old female patient who developed this mortal complication; a computed tomography (CT) examination was performed in articulo mortis by the physicians. Autopsy was unreliable because of bizarre post-mortem changes (reabsorption of intra-cardiac gas vs. conservation of intra-cranial gas) and a lack of strong diagnostic value of histological findings. The right diagnosis was possible thanks only to the CT examination that permitted the assumption of this possible cause of death before the autopsy and to prepare the necessary procedures to recognise and probe air embolism. This case exemplifies how early post-mortem imaging can be crucial to avoid a wrong diagnosis. © The Author(s) 2015.

  10. Papillary fibroelastoma arising from the coumadin ridge

    Directory of Open Access Journals (Sweden)

    Mahim Malik

    2017-06-01

    Full Text Available Cardiac papillary fibroelastomas (CPF are rare cardiac tumors, mostly found on the valvular surfaces in the heart. These tumors are frond like in nature and are benign, intracardiac masses, rarely causing any hemodynamic disturbances. However, excision of these masses is indicated due to their propensity to embolize. We present a case report of the tumor found on the coumadin ridge, causing transient ischemic attacks in a patient. We performed complete excision of the tumor via median sternotomy on cardiopulmonary bypass support with cardiac arrest. The diagnosis was confirmed by histological examination. The patient had an uneventful postoperative course and was discharghed on postoperative day 4. She has had complete resolution of her symptoms post excision. The diagnosis of the mass was confirmed on histological examination.

  11. A 'one in a million' case of pulsating thoracoabdominal mass.

    LENUS (Irish Health Repository)

    Tan, Lay Ong

    2012-11-01

    Ectopia cordis is a rare congenital malformation in which the heart is located partially or totally outside the thoracic cavity. It comprises 0.1% of congenital heart diseases. The authors present a case of a male baby born at term by emergency caesarean section due to prolonged fetal bradycardia, who was noted to have a large pulsating mass in the thoracoabdominal area. In view of lower thoracolumbar abdominal defect, ectopic placement of the umbilicus, deficiency of the diaphragmatic pericardium, deficiency of anterior diaphragm and intracardiac abnormalities, a diagnosis of ectopia cordis-Pentalogy of Cantrell was made. He was transferred to a tertiary centre and required oxygen supplement initially. He was sent home after 1 week, on propanolol, with weekly oxygen saturation checks. He is awaiting further surgical intervention pending the required weight gain.

  12. Limited access atrial septal defect closure and the evolution of minimally invasive surgery.

    Science.gov (United States)

    Izzat, M B; Yim, A P; El-Zufari, M H

    1998-04-01

    While minimizing the "invasiveness" in general surgery has been equated with minimizing "access", what constitutes minimally invasive intra-cardiac surgery remains controversial. Many surgeons doubt the benefits of minimizing access when the need for cardiopulmonary bypass cannot be waived. Recognizing that median sternotomy itself does entail significant morbidity, we investigated the value of alternative approaches to median sternotomy using atrial septal defect closure as our investigative model. We believe that some, but not all minimal access approaches are associated with reduced postoperative morbidity and enhanced recovery. Our current strategy is to use a mini-sternotomy approach in adult patients, whereas conventional median sternotomy remains our standard approach in the pediatric population. Considerable clinical experiences coupled with documented clinical benefits are fundamental before a certain approach is adopted in routine practice.

  13. A floating right heart thrombus in transit across tricuspid valve causing an endocardial friction rub

    Directory of Open Access Journals (Sweden)

    Babu Kanjirakadavath

    2013-07-01

    Full Text Available We report a 42-year-old lady on combined oral contraceptive pills with deep venous thrombosis and mild pulmonary embolism, who developed shock, while being treated with heparin. On auscultation, there was an unexpected loud, superficial, squeaky, triphasic friction rub over the left lower parasternal area. Simultaneous echocardiogram revealed a large serpiginous, freely floating mass in right atrium, prolapsing freely to right ventricular inlet across the tricuspid valve. The endocardial friction rub persisted for about 24 h as long as the thrombus was intracardiac and disappeared when the thrombus disappeared from right heart, occluding the proximal left pulmonary artery. She died due to shock awaiting surgery. We highlight that such a rub in a patient with deep venous thrombosis, though rare, may be an important clue to impending pulmonary embolism.

  14. Catheter Ablation of Atrial Fibrillation in Patients with Hardware in the Heart - Septal Closure Devices, Mechanical Valves and More.

    Science.gov (United States)

    Bartoletti, Stefano; Santangeli, Pasquale; DI Biase, Luigi; Natale, Andrea

    2013-01-01

    Patients with mechanical "hardware" in the heart, such as those with mechanical cardiac valves or atrial septal closure devices, represent a population at high risk of developing AF. Catheter ablation of AF in these subjects might represent a challenge, due to the perceived higher risk of complications associated with the presence of intracardiac mechanical devices. Accordingly, such patients were excluded or poorly represented in major trials proving the benefit of catheter ablation for the rhythm-control of AF. However, recent evidence supports the concept that catheter ablation procedures might be equally effective in these patients, without a significant increase in the risk of procedural complications. This review will summarize the current state-of-the-art on catheter ablation of AF in patients with mechanical "hardware" in the heart.

  15. Surface morphology of the endolymphatic duct in the rat. A scanning electron microscopy study

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, Jørgen; Bretlau, P

    1995-01-01

    microscopy was attained by coating of the specimens with osmium tetroxide and thiocarbohydrazide followed by a continuous dehydration procedure. This technique permitted, for the first time, an investigation of the surface morphology of the epithelial cells in the endolymphatic duct. Three types of cells......Following intracardiac vascular perfusion fixation of 8 rats with glutaraldehyde in a buffered and oxygenated blood substitute, the vestibular aqueduct and endolymphatic duct were opened by microsurgery of the resulting 16 temporal bones. Optimum preservation of the epithelium for scanning electron...... were identified with the scanning electron microscope. A polygonal and oblong epithelial cell was observed in the largest number throughout the duct, and in the juxtasaccular half of the duct, two additional types of epithelial cells were observed. The scanning electron microscopic observations...

  16. Multiple self-inserted pins and nails in pericardium in a patient of schizophrenia: Case report and review

    Directory of Open Access Journals (Sweden)

    S Soren

    2015-01-01

    Full Text Available This report is the case of multiple self-inserted pins and nails in chest and pericardial cavity in a young male suffering from schizophrenia. This act of self-mutilation was done to get relief from burning sensation in chest and palpitations. Review of the relevant literature revealed that self-inflicted intra-cardiac needle injuries occur mainly in young and middle-aged adults suffering from psychiatric disorders, commonly depression, schizophrenia, and substance use disorders. In one-fourth of the patients, it is due to deliberate self-harm. About 70% use a single needle but 30% may use multiple needles. Second attempts are rare. Majority of the patients (85% are managed by surgery and recover from the injury. The condition has a low mortality rate of 5%.

  17. Correção total da tétrade de Fallot no primeiro ano de vida

    Directory of Open Access Journals (Sweden)

    Fernando MORAES NETO

    1998-01-01

    Full Text Available De janeiro de 1996 a novembro de 1997, 15 crianças com idade variando de 3 a 11 meses (média: 6 meses e pesando entre 5 kg a 9 kg (média: 7,2 kg foram eletivamente submetidas à correção total de tétrade de Fallot. Treze tinham sintomas de hipoxemia, e 2 eram acianóticos. O diagnóstico definitivo foi obtido em todos os casos por ecocardiografia bidimensional. Utilizou-se circulação extracorpórea convencional e hipotermia moderada. Obteve-se proteção miocárdica com infusão na aorta de solução cardioplégica cristalóide gelada e hipotermia tópica do coração. O tempo de CEC variou de 50 min a 125 min (média: 56 min e o de pinçamento aórtico de 32 min a 86 min (média: 56 min. A correção foi realizada por via transventricular em 14 e por via transatrial em 1. Em 11 casos, utilizou-se enxerto de pericárdio bovino para ampliar a via de saída do ventrículo direito, sendo que em 4 a ampliação foi transanular. Após a correção, o gradiente entre o ventrículo direito e a artéria pulmonar variou de 2 a 25 mmHg (média: 12 mmHg. Não ocorreram óbitos ou complicações significativas nesta série. Conclui-se que a correção total da tétrade de Fallot no primeiro ano de vida pode ser realizada com baixa mortalidade, podendo essa conduta ter vantagens sobre a correção em dois tempos.From January 1996, to November 1997, 15 consecutive infants ranging in age from 3 to 11 months (mean: 6 months and weigh ing from 5 to 9 kilograms (mean: 7.2 kilograms underwent elective total repair of tetralogy of Fallot. Thirteen had symptoms of hypoxemia and two were acyanotic. Definitive diagnosis was established in all cases by two-dimensional echocardiography. Intracardiac correction was accomplished with conventional cardiopulmonary bypass and moderate hypothermia. Myocardial protection was obtained by cold cristaloide cardioplegia infused into the aorta and topical hypothermia of the heart. Bypass time ranged from 50 to 125 minutes

  18. The impact of the CartoSound® image directly acquired from the left atrium for integration in atrial fibrillation ablation.

    Science.gov (United States)

    Kaseno, Kenichi; Hisazaki, Kaori; Nakamura, Kohki; Ikeda, Etsuko; Hasegawa, Kanae; Aoyama, Daisetsu; Shiomi, Yuichiro; Ikeda, Hiroyuki; Morishita, Tetsuji; Ishida, Kentaro; Amaya, Naoki; Uzui, Hiroyasu; Tada, Hiroshi

    2018-04-14

    Intracardiac echocardiographic (ICE) imaging might be useful for integrating three-dimensional computed tomographic (CT) images for left atrial (LA) catheter navigation during atrial fibrillation (AF) ablation. However, the optimal CT image integration method using ICE has not been established. This study included 52 AF patients who underwent successful circumferential pulmonary vein isolation (CPVI). In all patients, CT image integration was performed after the CPVI with the following two methods: (1) using ICE images of the LA derived from the right atrium and right ventricular outflow tract (RA-merge) and (2) using ICE images of the LA directly derived from the LA added to the image for the RA-merge (LA-merge). The accuracy of these two methods was assessed by the distances between the integrated CT image and ICE image (ICE-to-CT distance), and between the CT image and actual ablated sites for the CPVI (CT-to-ABL distance). The mean ICE-to-CT distance was comparable between the two methods (RA-merge = 1.6 ± 0.5 mm, LA-merge = 1.7 ± 0.4 mm; p = 0.33). However, the mean CT-to-ABL distance was shorter for the LA-merge (2.1 ± 0.6 mm) than RA-merge (2.5 ± 0.8 mm; p imaging, and whereas the greatest CT-to-ABL distance was observed at the roof portion of the left superior PV (3.7 ± 2.8 mm) after the RA-merge, it improved to 2.6 ± 1.9 mm after the LA-merge (p images of the LA directly acquired from the LA might lead to a greater accuracy of the CT image integration for the CVPI.

  19. A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    Science.gov (United States)

    Kong, Wei; Huang, Jian; Rollins, Dennis L; Ideker, Raymond E; Smith, William M

    2007-03-01

    We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and coronary artery blood flow and arterial blood pressure that are suitable for use with the system. The telemetry system consists of a front end, a backpack and a host PC. The front end is a watertight stainless steel case with all sensor electronics sealed inside; it acquires dimension, flow, pressure and five cardiac electrograms from selected locations on the heart. The backpack includes a control unit, Bluetooth radio, and batteries. The control unit digitizes eight channels of data from the front end and forwards them to the host PC via Bluetooth link. The host PC has a receiving Bluetooth radio and Labview programs to store and display data. The whole system was successfully tested on the bench and in an animal model. This telemetry system will greatly enhance the ability to study events leading to spontaneous sudden cardiac arrest.

  20. Acute termination of human atrial fibrillation by identification and catheter ablation of localized rotors and sources: first multicenter experience of focal impulse and rotor modulation (FIRM) ablation.

    Science.gov (United States)

    Shivkumar, Kalyanam; Ellenbogen, Kenneth A; Hummel, John D; Miller, John M; Steinberg, Jonathan S

    2012-12-01

    Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets. We prospectively enrolled the first (n = 14, 11 males) consecutive patients undergoing FIRM-guided ablation for persistent (n = 11) and paroxysmal AF at 5 centers. A 64-pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10% cycle length prolongation). Conventional ablation was performed only after FIRM-guided ablation. Twelve out of 14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9 ± 0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM-guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n = 8 (4.9 ± 3.9 minutes at the primary source), and organization in n = 4. Total FIRM time for all patients was 12.3 ± 8.6 minutes. FIRM-guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM-guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation. © 2012 Wiley Periodicals, Inc.

  1. Comparison of Protective Effect of Green Tea and Vitamin C Against Cypermethrin Induce Nephrotoxicity in Mice

    International Nuclear Information System (INIS)

    Manzoor, S.; Mehboob, K.; Naveed, A. K.

    2016-01-01

    Background: Insecticide toxicity is the problem of every person in under developed countries. It is necessary to counteract its effect by natural and cheap remedies like green tea and vitamin C. In this manner common man can also enjoy blessings of life. The current research was performed to compare the protective function of green tea and vitamin C on experimental cypermethrin provoked nephrotoxicity Method: Forty healthy Balb/C mice purchased from National Institute of Health, Islamabad, Pakistan and divided in to four groups (10 each). Group a was control which received only normal diet. Group B, group C and group D were experimental groups which were given Cypermethrin, Cypermethrin with green tea and Cypermethrin with vitamin C respectively. These groups were also given normal diet. After 1 month blood was drawn by intra-cardiac method to assess renal parameters. Results: One month research showed increase in serum urea to 6.8±.48 m.mol/l (n=3.9±.44) while green tea and vitamin C normalize them to 4.0±.83 m.mol/l and 3.4±.33 m.mol/l respectively. Serum creatinine increased to 42.90±3.28 m.mol/l (n=29.50±3.95) while green tea and vitamin C normalize them to 28.80±4.58 m.mol/l and 22.60±2.06 m.mol/l correspondingly. Conclusion The results showed that green tea and vitamin C neutralized toxicity induced by Cypermethrin in mice and their effect is comparable. (author)

  2. Experimental transapical endoscopic ventricular visualization and mitral repair.

    Science.gov (United States)

    Ruttkay, Tamas; Czesla, Markus; Nagy, Henrietta; Götte, Julia; Baksa, Gabor; Patonay, Lajos; Doll, Nicolas; Galajda, Zoltan

    2015-04-01

    An increasing number of experimental beating heart animal studies describe simple transapical mitral valve repairs based on the direct endoscopic visualization of the left ventricle. The aim of our human cadaveric study was to develop a method for more complex transapical endoscopic procedures by on-pump heart operations. After preparation of 20 human fresh cadavers, a standard left anterolateral minithoracotomy was performed in the fifth intercostal space and the pericardium was entered. A rigid 0 degree endoscope and the instruments were introduced through a silicon apical port. To restore the natural form of the left heart, CO2 was insufflated. To test the mitral valve competence, the left ventricle was pressure-injected with saline after each step. After transecting the chords of the A2 segment of the anterior mitral leaflet before the experimental mitral valve repair, the tendinous chord was replaced using an especially designed clip chord. The second part of the experiment consisted of a segmental excision of the P2 segment of the posterior mitral leaflet followed by a standard valvuloplasty and suture annuloplasty. With the help of the described transapical endoscopic mitral valve repair technique, we gained direct visual information of the coaptation line of the mitral leaflets as well as the anatomy and function of the subvalvular apparatus. Using intracardiac imaging, we could perform successful transapical complex mitral repair in each case. The minimally invasive transapical endoscopic method has the potential to offer advantages for on-pump mitral valve repair procedures even in complex mitral valve repair cases. Georg Thieme Verlag KG Stuttgart · New York.

  3. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  4. Frequency of echocardiographic complications of dilated cardiomyopathy at a tertiary care hospital

    International Nuclear Information System (INIS)

    Rashid, A.; Ahmed, H.N.; Ahmed, N.

    2012-01-01

    Dilated cardiomyopathy can lead to a variety of complications recognisable on clinical, echocardiographic, electrocardiographic and radiographic assessment. Among this, transthoracic echocardiography has the dual advantage of being helpful in making the diagnosis of dilated cardiomyopathy as well as an effective tool in early recognition of certain complications for timely management to improve the quality of life of these patients. Methods: This descriptive (case series) study was undertaken at departments of medicine, cardiology, paediatrics and obs/gyn, Ayub Teaching Hospital, Abbottabad from July to December, 2008. fifty patients of dilated cardiomyopathy without age and gender discrimination were selected by convenience sampling. Those with hypertrophic and restrictive cardiomyopathies, valvular and congenital heart disease, hypertension and ischemic heart disease were excluded. Results: mean age was 47.12 +- 17.9 year with male predominance (males=34, females=16). Mean ejection fraction was 30.6 +- 6.9%. complications revealed on echocardiography were intracardiac thrombi (5, 10%), spontaneous echo contrast (5, 10%), pericardial effusion (6, 12%), mitral regurgitation (46, 92%), tricuspid (25, 50%), aortic (5, 10%), pulmonary (2, 4%) multi-valvular regurgitation (28, 56%), and left atrial dilatation (36, 72%). Conclusion: lv systolic dysfunction, cardiac thrombi, spontaneous echo contrast, mitral and tricuspid regurgitation and left atrial enlargement are important complications of dilated cardiomyopathy. echocardiography is important tool towards identification of these complications. (author)

  5. A Large Cardiac Mass: Diagnosis of Caseous Mitral Annular Calcification and Determining Optimum Management Strategy

    Directory of Open Access Journals (Sweden)

    Emanuel A. Shapera

    2014-01-01

    Full Text Available A 64-year-old woman with dizziness and blurry vision underwent an evaluation for a possible stroke with a head-neck CT scan and a transthoracic echocardiogram. The head-neck CT scan was unremarkable, but the echocardiogram was notable for a 2.0×2.3 cm heterogeneous echodensity attached to the mitral valve. After a transesophageal echocardiogram and chest CT scan, the mass was determined to be a caseous mitral annular calcification, CMAC. This entity is a rare variant of MAC with an estimated prevalence of 0.068%. Echocardiographic techniques can distinguish CMAC from other intracardiac masses such as tumor, cyst, or abscess. CMAC is associated with cerebrovascular accidents; however, optimal treatment is controversial given the rarity of this clinical finding. Management strategies should be tailored based on the patient’s presentation, risk factors, and overall clinical circumstances.

  6. [Clinicofunctional features of arterial hypertension in chronic broncho-obstructive syndrome].

    Science.gov (United States)

    Zadionchenko, V S; Kuz'micheva, N V; Sviridov, A A; Ol'kha, R P; Kashcheeva, E V

    2000-01-01

    To describe clinicofunctional features of essential and pulmogenic hypertension in chronic bronchoobstructive syndrome, 24-h profile of arterial pressure (AP), intracardiac hemodynamics and to propose differential diagnostic criteria for these hypertension forms. 24-h monitoring of arterial pressure (MAP), cardiohemodynamics, external respiration function (ERF) and blood gases examinations were made in 100 hypertensive subjects with chronic obstructive bronchitis and bronchial asthma. Significant differences were found between the groups of essential and pulmogenic hypertension by major values of MAP, echo-CG and ERF. Early disturbances in diastolic function of both the ventricles in essential and pulmonary hypertension in chronic bronchial obstruction arise long before clinical, x-ray and ECG signs of chronic pulmonary heart. The findings enable formulation of criteria of differential diagnosis of essential and pulmogenic hypertension and identify the latter as an independent nosological entity.

  7. Robotics in Cardiac Surgery: Past, Present, and Future

    Directory of Open Access Journals (Sweden)

    Bryan Bush

    2013-07-01

    Full Text Available Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review.

  8. International Conference eXtended Discretization MethodS

    CERN Document Server

    Benvenuti, Elena

    2016-01-01

    This book gathers selected contributions on emerging research work presented at the International Conference eXtended Discretization MethodS (X-DMS), held in Ferrara in September 2015. It highlights the most relevant advances made at the international level in the context of expanding classical discretization methods, like finite elements, to the numerical analysis of a variety of physical problems. The improvements are intended to achieve higher computational efficiency and to account for special features of the solution directly in the approximation space and/or in the discretization procedure. The methods described include, among others, partition of unity methods (meshfree, XFEM, GFEM), virtual element methods, fictitious domain methods, and special techniques for static and evolving interfaces. The uniting feature of all contributions is the direct link between computational methodologies and their application to different engineering areas.

  9. Method

    Directory of Open Access Journals (Sweden)

    Ling Fiona W.M.

    2017-01-01

    Full Text Available Rapid prototyping of microchannel gain lots of attention from researchers along with the rapid development of microfluidic technology. The conventional methods carried few disadvantages such as high cost, time consuming, required high operating pressure and temperature and involve expertise in operating the equipment. In this work, new method adapting xurography method is introduced to replace the conventional method of fabrication of microchannels. The novelty in this study is replacing the adhesion film with clear plastic film which was used to cut the design of the microchannel as the material is more suitable for fabricating more complex microchannel design. The microchannel was then mold using polymethyldisiloxane (PDMS and bonded with a clean glass to produce a close microchannel. The microchannel produced had a clean edge indicating good master mold was produced using the cutting plotter and the bonding between the PDMS and glass was good where no leakage was observed. The materials used in this method is cheap and the total time consumed is less than 5 hours where this method is suitable for rapid prototyping of microchannel.

  10. Method Points: towards a metric for method complexity

    Directory of Open Access Journals (Sweden)

    Graham McLeod

    1998-11-01

    Full Text Available A metric for method complexity is proposed as an aid to choosing between competing methods, as well as in validating the effects of method integration or the products of method engineering work. It is based upon a generic method representation model previously developed by the author and adaptation of concepts used in the popular Function Point metric for system size. The proposed technique is illustrated by comparing two popular I.E. deliverables with counterparts in the object oriented Unified Modeling Language (UML. The paper recommends ways to improve the practical adoption of new methods.

  11. BDF-methods

    DEFF Research Database (Denmark)

    Hostrup, Astrid Kuijers

    1999-01-01

    An introduction to BDF-methods is given. The use of these methods on differential algebraic equations (DAE's) with different indexes with respect to order, stability and convergens of the BDF-methods is presented.......An introduction to BDF-methods is given. The use of these methods on differential algebraic equations (DAE's) with different indexes with respect to order, stability and convergens of the BDF-methods is presented....

  12. Development of glia and blood vessels in the internal capsule of rats.

    Science.gov (United States)

    Earle, K L; Mitrofanis, J

    1998-02-01

    We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified

  13. Cross sectional imaging of cardiac tumors

    International Nuclear Information System (INIS)

    Maksimovic, R.

    2012-01-01

    Full text: Primary cardiac tumors are a rare entity whose incidence, according to surgery and autopsy reports, is 0.3% to 0.7% of all cardiac tumors. Metastasis to the heart from other primary cancers is 30 times more common. Only 25% of primary cardiac tumors are malignant, and, of these, 75% are sarcomas. Malignant primary cardiac sarcomas are usually located in the right atrium and are most commonly angiosarcoma. In the left atrium, the most common malignant tumors are pleomorphic sarcoma and leiomyosarcoma. Symptom presentation for cardiac tumors is quite varied, but it is dependent upon tumor location and size, rather than upon histologic characteristics. Presentation includes congestive heart failure from intracardiac obstruction, systemic embolization, constitutional symptoms, and arrhythmias. Left atrial sarcomas tend to be more solid and less infiltrative than right-sided sarcomas; consequently, they tend to metastasize later. They usually present with symptoms of blood-flow obstruction and substantial, life-threatening congestive heart failure. Right-sided cardiac tumors are usually malignant and appear as bulky, infiltrative masses that grow in an outward pattern. These are usually fast-growing tumors that metastasize early and do not present with congestive heart failure until late in the disease. The diagnosis of cardiac tumors relies heavily on the use of multiple imaging techniques, including cardiac computed tomography (CT), cardiovascular magnetic resonance (CMR), and echocardiography. Important imaging data to collect include information on the size of the intracardiac mass, the mobility of the mass (an important predictor of prognosis and embolic potential), myocardial invasion, and cardiac chamber location. These factors will provide the means to diagnosis and prognosis. Other important data to collect include the mechanism of tumor implantation, the relationship of the tumor with adjacent structures, the surgeon route of access to the heart

  14. Methods for evaluating imaging methods of limited reproducibility

    International Nuclear Information System (INIS)

    Krummenauer, F.

    2005-01-01

    Just like new drugs, new or modified imaging methods must be subjected to objective clinical tests, including tests on humans. In this, it must be ensured that the principle of Good Clinical Practice (GCP) are followed with regard to medical, administrative and methodical quality. Innovative methods fo clinical epidemiology and medical biometry should be applied from the planning stage to the final statistical evaluation. The author presents established and new methods for planning, evaluation and reporting of clinical tests of diagnostic methods, and especially imaging methods, in clinical medicine and illustrates these by means of current research projects in the various medical disciplines. The strategies presented are summarized in a recommendation based on the concept of phases I - IV of clinical drug testing in order to enable standardisation of the clinical evaluation of imaging methods. (orig.)

  15. Distillation methods

    International Nuclear Information System (INIS)

    Konecny, C.

    1975-01-01

    Two main methods of separation using the distillation method are given and evaluated, namely evaporation and distillation in carrier gas flow. Two basic apparatus are described for illustrating the methods used. The use of the distillation method in radiochemistry is documented by a number of examples of the separation of elements in elemental state, volatile halogenides and oxides. Tables give a survey of distillation methods used for the separation of the individual elements and give conditions under which this separation takes place. The suitability of the use of distillation methods in radiochemistry is discussed with regard to other separation methods. (L.K.)

  16. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  17. Epidemiology of Arrhythmias in Children

    Directory of Open Access Journals (Sweden)

    R Prem Sekar

    2008-05-01

    Full Text Available Unlike the adult population, arrhythmias occur less commonly in childhood. Only 5% of the emergency hospital admissions in the paediatric population is attributed to symptomatic arrhythmias. Majority of these tend to be accessory pathway mediated supraventricular tachyarrhythmias such as Wolff-Parkinson-White (WPW syndrome, permanent junctional reciprocating tachycardia (PJRT and Mahaim tachycardia. The non accessory pathway mediated supraventricular tachyarrhythmias commonly seen in children are junctional ectopic tachycardia (JET and automatic ectopic atrial tachycardia (AET and occur mostly in the post operative period after intracardiac repair for a structural heart defect. Ventricular tachycardia (VT although uncommon, occurs in the paediatric age group in association with hypertrophic cardiomyopathy (HCM, long QT syndrome (LQTS and Brugada syndrome. Occasionally, VT can also present symptomatically as incessant idiopathic infant ventricular tachycardia, right ventricular outflow tract tachycardia, benign VT, catecholaminic VT, idiopathic left ventricular tachycardia and in post cardiac surgical patients.

  18. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Hamada, Seiki; Takamiya, Makoto; Kuribayashi, Sachio; Naito, Hiroaki

    1994-01-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  19. Saudi Guidelines on the Diagnosis and Treatment of Pulmonary Hypertension: Pulmonary arterial hypertension associated with congenital heart disease

    Directory of Open Access Journals (Sweden)

    Antonio Lopes

    2014-01-01

    Full Text Available Congenital heart disease (CHD with intracardiac/extracardiac shunts is an important etiology of pulmonary arterial hypertension (PAH. The majority of children with congenital cardiac shunts do not develop advanced pulmonary vasculopathy, as surgical repair of the anomalies is now performed early in life. However, if not repaired early, some defects will inevitably lead to pulmonary vascular disease (truncus arteriosus, transposition of the great arteries associated with a ventricular septal defect (VSD, atrioventricular septal defects remarkably in Down syndrome, large, nonrestrictive VSDs, patent ductus arteriosus and related anomalies. The majority of patients are now assigned to surgery based on noninvasive evaluation only. PAH becomes a concern (requiring advanced diagnostic procedures in about 2-10% of them. In adults with CHD, the prevalence of advanced pulmonary vasculopathy (Eisenmenger syndrome is around 4-12%. [1] This article will discuss the diagnostic and management approach for PAH associated with CHD (PAH-CHD.

  20. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    Energy Technology Data Exchange (ETDEWEB)

    Teele, Sarah A.; Thiagarajan, Ravi R. [Children' s Hospital Boston, Department of Cardiology, Boston, MA (United States); Harvard Medical School, Department of Pediatrics, Boston, MA (United States); Emani, Sitaram M. [Children' s Hospital Boston, Department of Cardiac Surgery, Boston, MA (United States); Harvard Medical School, Department of Surgery, Boston, MA (United States); Teele, Rita L. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Starship Children' s Hospital, Department of Radiology, Grafton (New Zealand)

    2008-10-15

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  1. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  2. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Hamada, Seiki [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Takamiya, Makoto [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Kuribayashi, Sachio [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Naito, Hiroaki [Biomedical Research Center, Osaka Univ. School of Medicine, Suita (Japan)

    1994-10-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  3. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    International Nuclear Information System (INIS)

    Teele, Sarah A.; Thiagarajan, Ravi R.; Emani, Sitaram M.; Teele, Rita L.

    2008-01-01

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  4. Virtual In-Silico Modeling Guided Catheter Ablation Predicts Effective Linear Ablation Lesion Set for Longstanding Persistent Atrial Fibrillation: Multicenter Prospective Randomized Study.

    Science.gov (United States)

    Shim, Jaemin; Hwang, Minki; Song, Jun-Seop; Lim, Byounghyun; Kim, Tae-Hoon; Joung, Boyoung; Kim, Sung-Hwan; Oh, Yong-Seog; Nam, Gi-Byung; On, Young Keun; Oh, Seil; Kim, Young-Hoon; Pak, Hui-Nam

    2017-01-01

    Objective: Radiofrequency catheter ablation for persistent atrial fibrillation (PeAF) still has a substantial recurrence rate. This study aims to investigate whether an AF ablation lesion set chosen using in-silico ablation (V-ABL) is clinically feasible and more effective than an empirically chosen ablation lesion set (Em-ABL) in patients with PeAF. Methods: We prospectively included 108 patients with antiarrhythmic drug-resistant PeAF (77.8% men, age 60.8 ± 9.9 years), and randomly assigned them to the V-ABL ( n = 53) and Em-ABL ( n = 55) groups. Five different in-silico ablation lesion sets [1 pulmonary vein isolation (PVI), 3 linear ablations, and 1 electrogram-guided ablation] were compared using heart-CT integrated AF modeling. We evaluated the feasibility, safety, and efficacy of V-ABL compared with that of Em-ABL. Results: The pre-procedural computing time for five different ablation strategies was 166 ± 11 min. In the Em-ABL group, the earliest terminating blinded in-silico lesion set matched with the Em-ABL lesion set in 21.8%. V-ABL was not inferior to Em-ABL in terms of procedure time ( p = 0.403), ablation time ( p = 0.510), and major complication rate ( p = 0.900). During 12.6 ± 3.8 months of follow-up, the clinical recurrence rate was 14.0% in the V-ABL group and 18.9% in the Em-ABL group ( p = 0.538). In Em-ABL group, clinical recurrence rate was significantly lower after PVI+posterior box+anterior linear ablation, which showed the most frequent termination during in-silico ablation (log-rank p = 0.027). Conclusions: V-ABL was feasible in clinical practice, not inferior to Em-ABL, and predicts the most effective ablation lesion set in patients who underwent PeAF ablation.

  5. Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study

    Science.gov (United States)

    Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.

    2016-01-01

    Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009

  6. Predictors of ventricular tachyarrhythmia occurring late after intracardiac repair of tetralogy of Fallot: combination of QRS duration change rate and tricuspid regurgitation pressure gradient

    Science.gov (United States)

    Takahashi, Masashi; Sugimoto, Ai; Tsuchida, Masanori

    2017-01-01

    Background To determine potential predictors of ventricular tachyarrhythmia and sudden cardiac death (SCD) occurring late after repair of tetralogy of Fallot (TOF). Methods Since 1964, 415 patients had undergone total repair for TOF at Niigata University Hospital. Of these, 89 patients who were followed for more than 10 years at our institute were retrospectively reviewed. Results The mean follow-up period was 24.3 years. During the study period, one patient died of cerebral bleeding, and two patients had SCD. The overall survival rates at 20, 30, and 40 years were 100%, 94.6%, and 94.6%, respectively. Eight (9.0%) patients required re-intervention during the late period associated with right ventricular outflow (n=4), tricuspid valve (n=3), aortic valve (n=2), and others (n=2). Ten (11.2%) patients had a history of ventricular tachycardia (VT) or ventricular fibrillation (VF), and six underwent implantation of an implantable cardiac defibrillator. Multivariate analysis selected the change rate of QRS duration [ms/year; odds ratio (OR), 2.44; 95% confidence interval (CI): 1.28–4.65; P=0.007] and the pressure gradient at tricuspid valve regurgitation on echocardiography (OR, 1.12; 95% CI: 1.02–1.22; P=0.017) as risk factors for VT/VF or SCD. Trans-annular patch (TAP) repair was not an independent risk factor for ventricular arrhythmia. Conclusions The combination of rapid change rate of QRS duration and higher-pressure gradient at tricuspid regurgitation were risk factors for ventricular tachyarrhythmia late after TOF repair. Adequate surgical or catheter intervention for pressure and volume load in the right ventricle might decrease the prevalence of VT/VF and SCD. PMID:29312717

  7. Retrieval of an intra-cardiac embolised very long wire via transhepatic access from a war victim child.

    Science.gov (United States)

    Baspinar, Osman; Sahin, Derya A; Yildirim, Ali

    2016-04-01

    We present the case report of a war victim child with severe burn scars, orthopnoea, and dyspnoea due to diffuse pulmonary thromboembolism. During ICU stay, a central venous catheter's 45-mm wire embolised into the heart. The embolised wire was successfully removed via transhepatic access through the creation of an artificial simple snare.

  8. Impact of stepwise ablation on the biatrial substrate in patients with persistent atrial fibrillation and heart failure.

    Science.gov (United States)

    Jones, David G; Haldar, Shouvik K; Jarman, Julian W E; Johar, Sofian; Hussain, Wajid; Markides, Vias; Wong, Tom

    2013-08-01

    Ablation of persistent atrial fibrillation can be challenging, often involving not only pulmonary vein isolation (PVI) but also additional linear lesions and ablation of complex fractionated electrograms (CFE). We examined the impact of stepwise ablation on a human model of advanced atrial substrate of persistent atrial fibrillation in heart failure. In 30 patients with persistent atrial fibrillation and left ventricular ejection fraction ≤35%, high-density CFE maps were recorded biatrially at baseline, in the left atrium (LA) after PVI and linear lesions (roof and mitral isthmus), and biatrially after LA CFE ablation. Surface area of CFE (mean cycle length ≤120 ms) remote to PVI and linear lesions, defined as CFE area, was reduced after PVI (18.3±12.03 to 10.2±7.1 cm(2); Patrial CFE area was reduced by LA ablation, from 25.9±14.1 to 12.9±11.8 cm(2) (Patrial CFE area. Reduction of CFE area at sites remote from ablation would suggest either regression of the advanced atrial substrate or that these CFE were functional phenomena. Nevertheless, in an advanced atrial fibrillation substrate, linear lesions after PVI diminished the target area for CFE ablation, and complete lesions resulted in a favorable clinical outcome.

  9. Epicardial distribution of ST segment and T wave changes produced by stimulation of intrathoracic ganglia or cardiopulmonary nerves in dogs.

    Science.gov (United States)

    Savard, P; Cardinal, R; Nadeau, R A; Armour, J A

    1991-06-01

    Sixty-three ventricular epicardial electrograms were recorded simultaneously in 8 atropinized dogs during stimulation of acutely decentralized intrathoracic autonomic ganglia or cardiopulmonary nerves. Three variables were measured: (1) isochronal maps representing the epicardial activation sequence, (2) maps depicting changes in areas under the QRS complex and T wave (regional inhomogeneity of repolarization), and (3) local and total QT intervals. Neural stimulations did not alter the activation sequence but induced changes in the magnitude and polarity of the ST segments and T waves as well as in QRST areas. Stimulation of the same neural structure in different dogs induced electrical changes with different amplitudes and in different regions of the ventricles, except for the ventral lateral cardiopulmonary nerve which usually affected the dorsal wall of the left ventricle. Greatest changes occurred when the right recurrent, left intermediate medial, left caudal pole, left ventral lateral cardiopulmonary nerves and stellate ganglia were stimulated. Local QT durations either decreased or did not change, whereas total QT duration as measured using a root-mean-square signal did not change, indicating the regional nature of repolarization changes. Taken together, these data indicate that intrathoracic efferent sympathetic neurons can induce regional inhomogeneity of repolarization without prolonging the total QT interval.

  10. Mining Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shik; Lee, Kyung Woon; Kim, Oak Hwan; Kim, Dae Kyung [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    The reducing coal market has been enforcing the coal industry to make exceptional rationalization and restructuring efforts since the end of the eighties. To the competition from crude oil and natural gas has been added the growing pressure from rising wages and rising production cost as the workings get deeper. To improve the competitive position of the coal mines against oil and gas through cost reduction, studies to improve mining system have been carried out. To find fields requiring improvements most, the technologies using in Tae Bak Colliery which was selected one of long running mines were investigated and analyzed. The mining method appeared the field needing improvements most to reduce the production cost. The present method, so-called inseam roadway caving method presently is using to extract the steep and thick seam. However, this method has several drawbacks. To solve the problems, two mining methods are suggested for a long term and short term method respectively. Inseam roadway caving method with long-hole blasting method is a variety of the present inseam roadway caving method modified by replacing timber sets with steel arch sets and the shovel loaders with chain conveyors. And long hole blasting is introduced to promote caving. And pillar caving method with chock supports method uses chock supports setting in the cross-cut from the hanging wall to the footwall. Two single chain conveyors are needed. One is installed in front of chock supports to clear coal from the cutting face. The other is installed behind the supports to transport caved coal from behind. This method is superior to the previous one in terms of safety from water-inrushes, production rate and productivity. The only drawback is that it needs more investment. (author). 14 tabs., 34 figs.

  11. Utilidade do Ultrassom intracardíaco no isolamento de veias pulmonares usando cateter-balão a laser Utilidad del ultrasonido intracardíaco en el aislamiento de venas pulmonares usando catéter-balón láser Utility of intracardiac ultrasound imaging to guide pulmonary vein ablation using laser balloon catheter

    Directory of Open Access Journals (Sweden)

    Luiz Leite

    2009-12-01

    . Se obtuvo el aislamiento completo en 38/59 (64%, y fue significantemente más común sin derrame: [30/38 (79% versus 8/23 (35%, pBACKGROUND: Pulmonary vein isolation (PVI with balloon catheter has been used as the endpoint for AF ablation. OBJECTIVE: To determine the usefulness of intracardiac ultrasound (ICUS to guide PVI using laser balloon catheter. METHODS: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. RESULTS: 59 PV were ablated. Mean burn time was 279±177 sec, mean balloon diameter was 23±3 mm, and mean balloon length was 25±4 mm. Complete isolation was achieved in 38/59 (64% cases, and it was significantly more common when there was no leak: [30/38 (79% versus 8/23 (35%, p<0.001]. This occurred regardless of time of laser application (302±223 sec. vs. 266±148 sec., p=ns, laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm, balloon diameter (24± 3 mm vs. 22± 3 mm, p=ns and length (27±4 mm vs. 24±4mm, p=ns. The positive predictive value for predicting incomplete isolation was 65% and the negative predictive value was 83%. CONCLUSION: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.

  12. Perturbation methods

    CERN Document Server

    Nayfeh, Ali H

    2008-01-01

    1. Introduction 1 2. Straightforward Expansions and Sources of Nonuniformity 23 3. The Method of Strained Coordinates 56 4. The Methods of Matched and Composite Asymptotic Expansions 110 5. Variation of Parameters and Methods of Averaging 159 6. The Method of Multiple Scales 228 7. Asymptotic Solutions of Linear Equations 308 References and Author Index 387 Subject Index 417

  13. A Novel Polygonal Finite Element Method: Virtual Node Method

    Science.gov (United States)

    Tang, X. H.; Zheng, C.; Zhang, J. H.

    2010-05-01

    Polygonal finite element method (PFEM), which can construct shape functions on polygonal elements, provides greater flexibility in mesh generation. However, the non-polynomial form of traditional PFEM, such as Wachspress method and Mean Value method, leads to inexact numerical integration. Since the integration technique for non-polynomial functions is immature. To overcome this shortcoming, a great number of integration points have to be used to obtain sufficiently exact results, which increases computational cost. In this paper, a novel polygonal finite element method is proposed and called as virtual node method (VNM). The features of present method can be list as: (1) It is a PFEM with polynomial form. Thereby, Hammer integral and Gauss integral can be naturally used to obtain exact numerical integration; (2) Shape functions of VNM satisfy all the requirements of finite element method. To test the performance of VNM, intensive numerical tests are carried out. It found that, in standard patch test, VNM can achieve significantly better results than Wachspress method and Mean Value method. Moreover, it is observed that VNM can achieve better results than triangular 3-node elements in the accuracy test.

  14. Method Engineering: Engineering of Information Systems Development Methods and Tools

    NARCIS (Netherlands)

    Brinkkemper, J.N.; Brinkkemper, Sjaak

    1996-01-01

    This paper proposes the term method engineering for the research field of the construction of information systems development methods and tools. Some research issues in method engineering are identified. One major research topic in method engineering is discussed in depth: situational methods, i.e.

  15. Indium-111 labelled platelets: experimental and clinical studies

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.

    1985-10-01

    The object of the present study became to develop a method of effective and gentle isolation and 111-In labelling of human platelets, as well as to employ these platelets in human clinical studies with the object of elucidating a number of physiological and pathophysiological mechanisms and processes in which platelets take part. 111-In-oxine presents obvious advantages over 51-Cr-sodium chromate; a high labelling efficiency, and more advantageous physical properties (a half life of 68 hours (against the half life of 28 days for 51-Cr) and considerably more effective gamma emission), making external registration by means of a gamma camera possible. Considering the role played by platelets in the development of atherosclerosis and its thromboembolic complications, in the early phases of deep venous thrombosis, and in graft rejection, it is natural that attempts have been made to use 111-In-labelled platelets for scintigraphic and kinetic evaluation of thromboembolic processes. Accumulation of 111-In-labelled platelets at sites of vessel wall injury, on pulmonary emboli (presumably on deep vein thrombi as well), and on catheter material has been demonstrated. Beyond this, the number of publications concerning the use of 111-In-labelled platelets for visualization of atherosclerosis, venous thromboembolism, arterial grafts, intracardiac thrombi, aortic aneurysms, renal allograft rejection, and other situations in which platelet thromboembolism takes place, provides evidence that a tool has finally been found for the study of their nature and response to therapeutic intervention. (eg)

  16. Effect of visfatin on lipid profile of obese and diabetic mice

    International Nuclear Information System (INIS)

    Naz, R.; Hussain, M.M.; Aslam, M.

    2012-01-01

    Objective: To determine the effect of visfatin on blood lipid levels in balb/c strain of albino mice. Design: Quasi experimental study. Place and duration of study: The study was carried out at the department of Physiology, Army Medical College, Rawalpindi and National Institute of Health Sciences, Islamabad from April to December 2007. Material and Methods: One hundred and twenty balb/c strain albino mice were procured from NIH, Islamabad. After taking base line blood samples, mice were divided randomly into four groups. Animals in groups I and II were made obese by feeding high fat / high carbohydrate diet whereas mice in Groups III and IV were induced diabetes mellitus by injecting streptozotocin. Groups I (obese) and III (diabetic) served as controls whereas groups II (obese treated) and IV (diabetic treated) were administered visfatin injection. Terminal intracardiac blood sample was used to measure the serum lipid and visfatin levels. Results: Serum lipid levels were found increased in obese and diabetic groups as compared to healthy mice. The administration of recombinant-histidine soluble (mice) visfatin significantly (p< 0.01) decreased the serum lipid levels with concomitant increase in HDL levels (p< 0.01) in obese and diabetic groups of mice and were comparable with baseline normal values of healthy controls. Conclusion: Visfatin is a potential antilipidemic adipocytokine that probably modulates insulin sensitivity and decreases atherogenic lipids (triglycerides, cholesterol, LDL and VLDL) with concomitant increase in HDL in obesity and diabetes mellitus. (author)

  17. 1H NMR metabolomics identification of markers of hypoxia-induced metabolic shifts in a breast cancer model system

    International Nuclear Information System (INIS)

    Weljie, Aalim M.; Bondareva, Alla; Zang, Ping; Jirik, Frank R.

    2011-01-01

    Hypoxia can promote invasive behavior in cancer cells and alters the response to therapeutic intervention as a result of changes in the expression many genes, including genes involved in intermediary metabolism. Although metabolomics technologies are capable of simultaneously measuring a wide range of metabolites in an untargeted manner, these methods have been relatively under utilized in the study of cancer cell responses to hypoxia. Thus, 1 H NMR metabolomics was used to examine the effects of hypoxia in the MDA-MB-231 human breast cancer cell line, both in vitro and in vivo. Cell cultures were compared with respect to their metabolic responses during growth under either hypoxic (1% O 2 ) or normoxic conditions. Orthogonal partial least squares discriminant analysis (OPLS-DA) was used to identify a set of metabolites that were responsive to hypoxia. Via intracardiac administration, MDA-MB-231 cells were also used to generate widespread metastatic disease in immuno-compromised mice. Serum metabolite analysis was conducted to compare animals with and without a large tumor burden. Intriguingly, using a cross-plot of the OPLS loadings, both the in vitro and in vivo samples yielded a subset of metabolites that were significantly altered by hypoxia. These included primarily energy metabolites and amino acids, indicative of known alterations in energy metabolism, and possibly protein synthesis or catabolism. The results suggest that the metabolite pattern identified might prove useful as a marker for intra-tumoral hypoxia.

  18. Radiofrequency and microwave tumor ablation in patients with implanted cardiac devices: Is it safe?

    Energy Technology Data Exchange (ETDEWEB)

    Skonieczki, Brendan D., E-mail: bskonieczki@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Wells, Catherine, E-mail: cwells1@bidmc.harvard.edu [Department of Radiology, Harvard Medical School/Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Wasser, Elliot J., E-mail: ewasser@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States)

    2011-09-15

    Purpose: To identify malfunction of implanted cardiac devices during or after thermal ablation of tumors in lung, kidney, liver or bone, using radiofrequency (RF) or microwave (MW) energy. Materials and methods: After providing written consent, 19 patients (15 men and 4 women; mean age 78 years) with pacemakers or pacemaker/defibrillators underwent 22 CT image-guided percutaneous RF or MW ablation of a variety of tumors. Before and after each procedure, cardiac devices were interrogated and reprogrammed by a trained cardiac electrophysiology fellow. Possible pacer malfunctions included abnormalities on electrocardiographic (EKG) monitoring and alterations in device settings. Our institutional review board approved this Health Insurance Portability and Accountability Act-compliant study. Informed consent for participation in this retrospective study was deemed unnecessary by our review board. Results: During 20 of 22 sessions, no abnormalities were identified in continuous, EKG tracings or pacemaker functions. However, in two sessions significant changes, occurred in pacemaker parameters: inhibition of pacing during RF application in one, session and resetting of mode by RF energy in another session. These changes did not, result in hemodynamic instability of either patient. MW ablation was not associated with, any malfunction. In all 22 sessions, pacemakers were undamaged and successfully reset to original parameters. Conclusion: RF or MW ablation of tumors in liver, kidney, bone and lung can be performed safely in patients with permanent intra-cardiac devices, but careful planning between radiology and cardiology is essential to avoid adverse outcomes.

  19. Enhancing the (MSLDIP) image steganographic method (ESLDIP method)

    Science.gov (United States)

    Seddik Saad, Al-hussien

    2011-10-01

    Message transmissions over the Internet still have data security problem. Therefore, secure and secret communication methods are needed for transmitting messages over the Internet. Cryptography scrambles the message so that it cannot be understood. However, it makes the message suspicious enough to attract eavesdropper's attention. Steganography hides the secret message within other innocuous-looking cover files (i.e. images, music and video files) so that it cannot be observed [1].The term steganography originates from the Greek root words "steganos'' and "graphein'' which literally mean "covered writing''. It is defined as the science that involves communicating secret data in an appropriate multimedia carrier, e.g., image, audio text and video files [3].Steganographic techniques allow one party to communicate information to another without a third party even knowing that the communication is occurring. The ways to deliver these "secret messages" vary greatly [3].Our proposed method called Enhanced SLDIP (ESLDIP). In which the maximmum hiding capacity (MHC) of proposed ESLDIP method is higher than the previously proposed MSLDIP methods and the PSNR of the ESLDIP method is higher than the MSLDIP PSNR values', which means that the image quality of the ESLDIP method will be better than MSLDIP method and the maximmum hiding capacity (MHC) also improved. The rest of this paper is organized as follows. In section 2, steganography has been discussed; lingo, carriers and types. In section 3, related works are introduced. In section 4, the proposed method will be discussed in details. In section 5, the simulation results are given and Section 6 concludes the paper.

  20. Method Engineering: Engineering of Information Systems Development Methods and Tools

    OpenAIRE

    Brinkkemper, J.N.; Brinkkemper, Sjaak

    1996-01-01

    This paper proposes the term method engineering for the research field of the construction of information systems development methods and tools. Some research issues in method engineering are identified. One major research topic in method engineering is discussed in depth: situational methods, i.e. the configuration of a project approach that is tuned to the project at hand. A language and support tool for the engineering of situational methods are discussed.

  1. Numerical Methods for Stochastic Computations A Spectral Method Approach

    CERN Document Server

    Xiu, Dongbin

    2010-01-01

    The first graduate-level textbook to focus on fundamental aspects of numerical methods for stochastic computations, this book describes the class of numerical methods based on generalized polynomial chaos (gPC). These fast, efficient, and accurate methods are an extension of the classical spectral methods of high-dimensional random spaces. Designed to simulate complex systems subject to random inputs, these methods are widely used in many areas of computer science and engineering. The book introduces polynomial approximation theory and probability theory; describes the basic theory of gPC meth

  2. Mining method selection by integrated AHP and PROMETHEE method.

    Science.gov (United States)

    Bogdanovic, Dejan; Nikolic, Djordje; Ilic, Ivana

    2012-03-01

    Selecting the best mining method among many alternatives is a multicriteria decision making problem. The aim of this paper is to demonstrate the implementation of an integrated approach that employs AHP and PROMETHEE together for selecting the most suitable mining method for the "Coka Marin" underground mine in Serbia. The related problem includes five possible mining methods and eleven criteria to evaluate them. Criteria are accurately chosen in order to cover the most important parameters that impact on the mining method selection, such as geological and geotechnical properties, economic parameters and geographical factors. The AHP is used to analyze the structure of the mining method selection problem and to determine weights of the criteria, and PROMETHEE method is used to obtain the final ranking and to make a sensitivity analysis by changing the weights. The results have shown that the proposed integrated method can be successfully used in solving mining engineering problems.

  3. [Effect of raw and cooked nopal (Opuntia ficus indica) ingestion on growth and profile of total cholesterol, lipoproteins, and blood glucose in rats].

    Science.gov (United States)

    Cárdenas Medellín, M L; Serna Saldívar, S O; Velazco de la Garza, J

    1998-12-01

    Two different concentrations (approx. 6 and 12%) and two presentations (raw and cooked) of dehydrated nopal were fed to laboratory rats and growth and serum total cholesterol, lipoprotein profile and glucose determined. Samples of raw and cooked nopal were chemically characterized for moisture, protein, ash, crude fiber, ether extract, total dietary fiber, reducing sugars, amino acids, minerals and gross energy. Cooking slightly affected some of the nutrients analyzed. After one month feeding, blood was withdrawn via intracardiac puncture and serum glucose, total cholesterol, HDL, LDL, and VLDL were determined. Rats fed 12% nopal had lower weight gains (P nopal or the control diet. Consumption of nopal did not affect (P > 0.05) glucose, total cholesterol and HDL cholesterol levels. However, rats fed raw nopal at the 12% concentration level had a 34% reduction in LDL cholesterol levels; thus, it was concluded that raw nopal had a potentially beneficial effect for hypercholesterolemic individuals.

  4. Towards robot-assisted anchor deployment in beating-heart mitral valve surgery.

    Science.gov (United States)

    Cheng, Lingbo; Sharifi, Mojtaba; Tavakoli, Mahdi

    2018-06-01

    Beating-heart intracardiac surgery promises significant benefits for patients compared with cardiopulmonary bypass based procedures. However, the fast motions of the heart introduce serious challenges for surgeons. In this work, a new impedance-controlled master-slave telerobotic system is developed to help perform anchor deployment for mitral valve annuloplasty under the guidance of live ultrasound images of the heart. The proposed bilateral teleoperation system can both reflect the non-oscillatory portion of slave-heart tissue interaction force on the surgeon's hand as haptic feedback and implement rapid compensation for the beating heart's motion. The surgical task involves performing anchor deployment on a simulated moving heart tissue to evaluate the effectiveness of the proposed strategy for safely interacting with a moving organ. The results obtained show that the telerobotic system increases the success rate of anchor deployment by 100% and reduces the excess force application rate by 70% compared with manual attempts. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  6. Changes in Cytokines of the Bone Microenvironment during Breast Cancer Metastasis

    International Nuclear Information System (INIS)

    Sosnoski, D.M.; Krishnan, V.; Mastro, A.M.; Kraemer, W.J.; Dunn-Lewis, C.

    2012-01-01

    It is commonly accepted that cancer cells interact with host cells to create a microenvironment favoring malignant colonization. The complex bone microenvironment produces an ever changing array of cytokines and growth factors. In this study, we examined levels of MCP-1, IL-6, KC, MIP-2, VEGF, MIG, and eotaxin in femurs of athymic nude mice inoculated via intracardiac injection with MDA-MB-231GFP human metastatic breast cancer cells, MDA-MB-231 BRMS1GFP, a metastasis suppressed variant, or PBS. Animals were euthanized (day 3, 11, 19, 27 after injection) to examine femoral cytokine levels at various stages of cancer cell colonization. The epiphysis contained significantly more cytokines than the diaphysis except for MIG which was similar throughout the bone. Variation among femurs was evident within all groups. By day 27, MCP-1, MIG, VEGF and eotaxin levels were significantly greater in femurs of cancer cell-inoculated mice. These pro-osteoclastic and angiogenic cytokines may manipulate the bone microenvironment to enhance cancer cell colonization

  7. Tromboembolismo pulmonar masivo de alto riesgo asociado a foramen oval permeable High-risk massive pulmonary thromboembolism associated with patent foramen ovale

    Directory of Open Access Journals (Sweden)

    Antonio Miranda

    2012-04-01

    Full Text Available La alta mortalidad de los pacientes con tromboembolismo pulmonar masivo de alto riesgo amerita un enfoque terapéutico enérgico e invasivo que incluya la embolectomía pulmonar quirúrgica en aquellos pacientes con contraindicación para trombolisis o trombolisis fallida. Describimos un caso de tromboembolismo pulmonar masivo de alto riesgo que recibió tratamiento quirúrgico en vez de trombolisis debido a que al momento del diagnóstico presentaba un trombo móvil a través de un foramen oval permeable con altísima posibilidad de embolismo paradójico arterial.High mortality rate associated with massive pulmonary embolism requires an aggressive invasive approach including surgical pulmonary embolectomy when thrombolytic therapy has failed or is contraindicated. We describe a case of high-risk massive pulmonary embolism who underwent surgical treatment due to the presence of a mobile intracardiac clot in a patent foramen ovale, and the possible risk of paradoxical arterial embolism.

  8. Systemic aspergilloma post aortic root surgery following coronary artery stenting: diagnostic and management dilemma

    Science.gov (United States)

    Hussein, Nabil; Qamar, Sombul; Abid, Qamar

    2015-01-01

    Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972

  9. July 2012 pulmonary case of the month: pulmonary infiltrates - getting to the heart of the problem

    Directory of Open Access Journals (Sweden)

    Ronan B

    2012-07-01

    Full Text Available No abstract available. Article truncated at 150 words. History of Present IllnessA 63 year old man was transferred from outside facility with ventricular tachycardia. He has a past history of ventricular tachycardia and had an intracardiac defibrillator (ICD placed due to a low ejection fraction. The ICD had administered several shocks to the patient prior to admission. His present medications included: •Lisinopril 10 mg bid •Diazepam 10 mg bid •Amiodarone 400 mg daily •Dutasteride 0.5 mg daily •Tamsulosin 0.4 mg daily •Dexlansoprazole 60 mg daily •Levothyroxine 100 mcg daily The patient underwent and electrophysiology (EP procedure. He was intubated prior to the procedure. He developed sustained ventricular tachycardia when the ICD was turned off. Eleven cardioversions were required with an accumulated 108 seconds of ventricular tachycardia. He became hypotensive and received 6.2 L boluses of fluids and 5, 400 mg boluses of amiodarone and was placed on an amiodarone drip...

  10. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  11. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  12. Peripheral vascular imaging

    International Nuclear Information System (INIS)

    Wilson, G.A.; O'Mara, R.E.

    1988-01-01

    Techniques for the evaluation of the cardiovascular system are among the oldest in nuclear medicine. Arm-to-arm circulation times were determined in humans using the naturally occurring radioactivity of radium. In 1948 artificially produced radioactive sodium was used to evaluate the circulation time through the heart in both normal subjects and patients with heart disease. This technique utilized an intravenous injection of sodium-24 into the antecubital vein of one arm and the generation of a graph of the count rate with a Geiger-Muller tube placed over the percordium as the radiolabeled blood passed through the chambers of the heart. This simple measurement had many components to it: a venous phase, a pulmonary circulation phase, and a phase for the cardiac chambers. Since this early work, the development of short-lived radiopharmaceuticals, advances in detection devices, and the introduction of computers into clinical nuclear medicine have permitted separation of these various components, allowing the study of venous, pulmonary, intracardiac, arterial, and capillary phases

  13. [Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

    Science.gov (United States)

    Santiago, Justo; Acuña, Manuel; Arispe, Elizabeth; Camargo, Ronaldo; Neves, Juliana; Arnoni, Daniel; Fontes, Valmir F; Pedra, Carlos A

    2007-03-01

    The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the defects using Amplatzer devices. In two patients, although angiography demonstrated the presence of type-A patent ductus arteriosus, it was not possible to determine the minimum diameter accurately and it was necessary to measure it using a sizing balloon. An Amplatzer duct occluder was used in two patients and an Amplatzer muscular ventricular septal defect occluder, in the other. In all patients, full closure was confirmed in the catheterization laboratory and the patients were discharged on the same day with no complications. Percutaneous closure of a right patent ductus arteriosus associated with a right aortic arch is feasible, safe and effective.

  14. Cardiovascular effects of metrizamide in infants

    International Nuclear Information System (INIS)

    DiSessa, T.G.; Zednikova, M.; Hiraishi, S.; Jarmakani, J.M.; Higgins, C.B.; Friedman, W.F.

    1983-01-01

    A prospective study was performed in 30 children under 3 years of age to compare the cardiovascular effects of a nonionic contrast material of low osmolality, metrizamide, with those of a conventional ionic contrast material, meglumine sodium diatrizoate. Left ventricular end-diastolic pressure, left ventricular peak systolic pressure, heart rate, echocardiographically obtained end-diastolic and end-systolic dimension, and blood chemistries were obtained before and after angiography. Neither contrast material changed serum sodium, potassium, or creatinine levels. However, serum osmolality rose significantly following injection of diatrizoate, but not metrizamide. Both end-diastolic and end-systolic dimensions increased after diatrizoate injection. However, end-diastolic dimension was unchanged and end-systolic dimension fell after metrizamide infusion. It is concluded that although the effects on intracardiac pressures are similar for both contrast materials, metrizamide may be advantageous in the critically ill infant because it causes a smaller increase in osmolality, fewer changes in cardiac dimensions, and a reduced heart rate challenge

  15. Remote Ischemic Conditioning

    Science.gov (United States)

    Heusch, Gerd; Bøtker, Hans Erik; Przyklenk, Karin; Redington, Andrew; Yellon, Derek

    2014-01-01

    In remote ischemic conditioning (RIC) brief, reversible episodes of ischemia with reperfusion in one vascular bed, tissue or organ confer a global protective phenotype and render remote tissues and organs resistant to ischemia/reperfusion injury. The peripheral stimulus can be chemical, mechanical or electrical and involves activation of peripheral sensory nerves. The signal transfer to the heart or other organs is through neuronal and humoral communications. Protection can be transferred, even across species, with plasma-derived dialysate and involves nitric oxide, stromal derived factor-1α, microRNA-144, but also other, not yet identified factors. Intracardiac signal transduction involves: adenosine, bradykinin, cytokines, and chemokines, which activate specific receptors; intracellular kinases; and mitochondrial function. RIC by repeated brief inflation/deflation of a blood pressure cuff protects against endothelial dysfunction and myocardial injury in percutaneous coronary interventions, coronary artery bypass grafting and reperfused acute myocardial infarction. RIC is safe and effective, noninvasive, easily feasible and inexpensive. PMID:25593060

  16. A Pattern-Oriented Approach to a Methodical Evaluation of Modeling Methods

    Directory of Open Access Journals (Sweden)

    Michael Amberg

    1996-11-01

    Full Text Available The paper describes a pattern-oriented approach to evaluate modeling methods and to compare various methods with each other from a methodical viewpoint. A specific set of principles (the patterns is defined by investigating the notations and the documentation of comparable modeling methods. Each principle helps to examine some parts of the methods from a specific point of view. All principles together lead to an overall picture of the method under examination. First the core ("method neutral" meaning of each principle is described. Then the methods are examined regarding the principle. Afterwards the method specific interpretations are compared with each other and with the core meaning of the principle. By this procedure, the strengths and weaknesses of modeling methods regarding methodical aspects are identified. The principles are described uniformly using a principle description template according to descriptions of object oriented design patterns. The approach is demonstrated by evaluating a business process modeling method.

  17. Maintenance methods

    International Nuclear Information System (INIS)

    Sanchis, H.; Aucher, P.

    1990-01-01

    The maintenance method applied at the Hague is summarized. The method was developed in order to solve problems relating to: the different specialist fields, the need for homogeneity in the maintenance work, the equipment diversity, the increase of the materials used at the Hague's new facilities. The aim of the method is to create a knowhow formalism, to facilitate maintenance, to ensure the running of the operations and to improve the estimation of the maintenance cost. One of the method's difficulties is the demonstration of the profitability of the maintenance operations [fr

  18. BASIC METHODS OF CLASSIFICATION AND CHARACTERISTICS OF METHODS OF PRICING IN UKRAINE

    Directory of Open Access Journals (Sweden)

    A. Boguslavskiy

    2014-12-01

    Full Text Available The article provided definitions and shows the need to use different methods of pricing of enterprises. Exposed the reasons of the absence of a universal classification of pricing methods. The approaches of different authors to classify groups of pricing methods: 1 the cost method; 2 methods with a focus on competition; 3 methods for pricing based on demand, 4 pricing with a focus on maximum profit, 5 parametric methods, 6 pricing under risk and uncertainty, etc. An improved classification pricing methods with the release of the following groups: 1 the methods of cost pricing; 2 methods based on demand; 3 methods, based on competition; 4 microeconomic methods; 5 methods which are based on product life cycles; 6 methods, depending on economic conditions; 7 econometric and statistical techniques 8 Methods of transfer pricing; 9 methods in accordance with the terms of agreements; 10 Methods of assortment pricing; 11 combined methods of pricing and so on. The basic directions of use of combined methods of pricing and analysis of their possible use in Ukraine are shown.

  19. Comparative law as method and the method of comparative law

    NARCIS (Netherlands)

    Hage, J.C.; Adams, M.; Heirbaut, D.

    2014-01-01

    This article addresses both the justificatory role of comparative law within legal research (comparative law as method) and the method of comparative law itself. In this connection two questions will be answered: 1. Is comparative law a method, or a set of methods, for legal research? 2. Does

  20. Safety training for working youth: Methods used versus methods wanted.

    Science.gov (United States)

    Zierold, Kristina M

    2016-04-07

    Safety training is promoted as a tool to prevent workplace injury; however, little is known about the safety training experiences young workers get on-the-job. Furthermore, nothing is known about what methods they think would be the most helpful for learning about safe work practices. To compare safety training methods teens get on the job to those safety training methods teens think would be the best for learning workplace safety, focusing on age differences. A cross-sectional survey was administered to students in two large high schools in spring 2011. Seventy percent of working youth received safety training. The top training methods that youth reported getting at work were safety videos (42%), safety lectures (25%), and safety posters/signs (22%). In comparison to the safety training methods used, the top methods youth wanted included videos (54%), hands-on (47%), and on-the-job demonstrations (34%). This study demonstrated that there were differences in training methods that youth wanted by age; with older youth seemingly wanting more independent methods of training and younger teens wanting more involvement. Results indicate that youth want methods of safety training that are different from what they are getting on the job. The differences in methods wanted by age may aid in developing training programs appropriate for the developmental level of working youth.

  1. The Monte Carlo method the method of statistical trials

    CERN Document Server

    Shreider, YuA

    1966-01-01

    The Monte Carlo Method: The Method of Statistical Trials is a systematic account of the fundamental concepts and techniques of the Monte Carlo method, together with its range of applications. Some of these applications include the computation of definite integrals, neutron physics, and in the investigation of servicing processes. This volume is comprised of seven chapters and begins with an overview of the basic features of the Monte Carlo method and typical examples of its application to simple problems in computational mathematics. The next chapter examines the computation of multi-dimensio

  2. Catalysts, methods of making catalysts, and methods of use

    KAUST Repository

    Renard, Laetitia; El Eter, Mohamad; Caps, Valerie; Basset, Jean-Marie

    2014-01-01

    Embodiments of the present disclosure provide for catalysts, methods of making catalysts, methods of using catalysts, and the like. In an embodiment, the method of making the catalysts can be performed in a single step with a metal nanoparticle precursor and a metal oxide precursor, where a separate stabilizing agent is not needed.

  3. Catalysts, methods of making catalysts, and methods of use

    KAUST Repository

    Renard, Laetitia

    2014-03-06

    Embodiments of the present disclosure provide for catalysts, methods of making catalysts, methods of using catalysts, and the like. In an embodiment, the method of making the catalysts can be performed in a single step with a metal nanoparticle precursor and a metal oxide precursor, where a separate stabilizing agent is not needed.

  4. A comparison of Ki-67 counting methods in luminal Breast Cancer: The Average Method vs. the Hot Spot Method.

    Science.gov (United States)

    Jang, Min Hye; Kim, Hyun Jung; Chung, Yul Ri; Lee, Yangkyu; Park, So Yeon

    2017-01-01

    In spite of the usefulness of the Ki-67 labeling index (LI) as a prognostic and predictive marker in breast cancer, its clinical application remains limited due to variability in its measurement and the absence of a standard method of interpretation. This study was designed to compare the two methods of assessing Ki-67 LI: the average method vs. the hot spot method and thus to determine which method is more appropriate in predicting prognosis of luminal/HER2-negative breast cancers. Ki-67 LIs were calculated by direct counting of three representative areas of 493 luminal/HER2-negative breast cancers using the two methods. We calculated the differences in the Ki-67 LIs (ΔKi-67) between the two methods and the ratio of the Ki-67 LIs (H/A ratio) of the two methods. In addition, we compared the performance of the Ki-67 LIs obtained by the two methods as prognostic markers. ΔKi-67 ranged from 0.01% to 33.3% and the H/A ratio ranged from 1.0 to 2.6. Based on the receiver operating characteristic curve method, the predictive powers of the KI-67 LI measured by the two methods were similar (Area under curve: hot spot method, 0.711; average method, 0.700). In multivariate analysis, high Ki-67 LI based on either method was an independent poor prognostic factor, along with high T stage and node metastasis. However, in repeated counts, the hot spot method did not consistently classify tumors into high vs. low Ki-67 LI groups. In conclusion, both the average and hot spot method of evaluating Ki-67 LI have good predictive performances for tumor recurrence in luminal/HER2-negative breast cancers. However, we recommend using the average method for the present because of its greater reproducibility.

  5. A comparison of Ki-67 counting methods in luminal Breast Cancer: The Average Method vs. the Hot Spot Method.

    Directory of Open Access Journals (Sweden)

    Min Hye Jang

    Full Text Available In spite of the usefulness of the Ki-67 labeling index (LI as a prognostic and predictive marker in breast cancer, its clinical application remains limited due to variability in its measurement and the absence of a standard method of interpretation. This study was designed to compare the two methods of assessing Ki-67 LI: the average method vs. the hot spot method and thus to determine which method is more appropriate in predicting prognosis of luminal/HER2-negative breast cancers. Ki-67 LIs were calculated by direct counting of three representative areas of 493 luminal/HER2-negative breast cancers using the two methods. We calculated the differences in the Ki-67 LIs (ΔKi-67 between the two methods and the ratio of the Ki-67 LIs (H/A ratio of the two methods. In addition, we compared the performance of the Ki-67 LIs obtained by the two methods as prognostic markers. ΔKi-67 ranged from 0.01% to 33.3% and the H/A ratio ranged from 1.0 to 2.6. Based on the receiver operating characteristic curve method, the predictive powers of the KI-67 LI measured by the two methods were similar (Area under curve: hot spot method, 0.711; average method, 0.700. In multivariate analysis, high Ki-67 LI based on either method was an independent poor prognostic factor, along with high T stage and node metastasis. However, in repeated counts, the hot spot method did not consistently classify tumors into high vs. low Ki-67 LI groups. In conclusion, both the average and hot spot method of evaluating Ki-67 LI have good predictive performances for tumor recurrence in luminal/HER2-negative breast cancers. However, we recommend using the average method for the present because of its greater reproducibility.

  6. Radiochemistry methods in DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.

    1994-08-01

    Current standard sources of radiochemistry methods are often inappropriate for use in evaluating US Department of Energy environmental and waste management (DOE/EW) samples. Examples of current sources include EPA, ASTM, Standard Methods for the Examination of Water and Wastewater and HASL-300. Applicability of these methods is limited to specific matrices (usually water), radiation levels (usually environmental levels), and analytes (limited number). Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) attempt to fill the applicability gap that exists between standard methods and those needed for DOE/EM activities. The Radiochemistry chapter in DOE Methods includes an ''analysis and reporting'' guidance section as well as radiochemistry methods. A basis for identifying the DOE/EM radiochemistry needs is discussed. Within this needs framework, the applicability of standard methods and targeted new methods is identified. Sources of new methods (consolidated methods from DOE laboratories and submissions from individuals) and the methods review process will be discussed. The processes involved in generating consolidated methods add editing individually submitted methods will be compared. DOE Methods is a living document and continues to expand by adding various kinds of methods. Radiochemistry methods are highlighted in this paper. DOE Methods is intended to be a resource for methods applicable to DOE/EM problems. Although it is intended to support DOE, the guidance and methods are not necessarily exclusive to DOE. The document is available at no cost through the Laboratory Management Division of DOE, Office of Technology Development

  7. METHODS IN THE POST-METHODS ERA. REPORT ON AN INTERNATIONAL SURVEY ON LANGUAGE TEACHING METHODS'

    Directory of Open Access Journals (Sweden)

    Jun Liu

    2004-06-01

    Full Text Available Do methods still have a place in 21" century language teaching? To answer this question, an international survey was conducted in the surnmer of 1999. A sample of 800 language teachers world-wide randomly drawn from 17,800 TESOLers were each given a 2-page survey. The return rate was 58.5% with the actual usable data set of448, which was analyzed by using both descriptive and inferential statistics. Among the ten commonly recognized teaching methods surveyed, both the Communicative Language Teaching Approach and an eclectic method seem to have the highest rate in familiarity, preference, and use. But when multiple factors, such as teaching contexts, instructional settings, learners' proficiency levels, class size, teaching experience and educational backgrounds of the teachers, and the status of being a native or nonnative English speaking professional were taken into consideration, various patterns and themes emerged. One interesting finding is that Grammar Translation is still used in EFL contexts, in larger classes, and with learners at low proficiency levels, though the ratio between the actual use of this method and teachers' preference does not match. Based on the results of the survey, a new theoretical framework is proposed to conceptualize language teaching methods in the post-methods era.

  8. A nodal method based on matrix-response method

    International Nuclear Information System (INIS)

    Rocamora Junior, F.D.; Menezes, A.

    1982-01-01

    A nodal method based in the matrix-response method, is presented, and its application to spatial gradient problems, such as those that exist in fast reactors, near the core - blanket interface, is investigated. (E.G.) [pt

  9. Functional Na(V)1.8 Channels in Intracardiac Neurons The Link Between SCN10A and Cardiac Electrophysiology

    NARCIS (Netherlands)

    Verkerk, Arie O.; Remme, Carol Ann; Schumacher, Cees A.; Scicluna, Brendon P.; Wolswinkel, Rianne; de Jonge, Berend; Bezzina, Connie R.; Veldkamp, Marieke W.

    2012-01-01

    Rationale: The SCN10A gene encodes the neuronal sodium channel isoform Na(V)1.8. Several recent genome-wide association studies have linked SCN10A to PR interval and QRS duration, strongly suggesting an as-yet unknown role for Na(V)1.8 in cardiac electrophysiology. Objective: To demonstrate the

  10. Commentary on: "Vascular distensibilities have minor effects on intracardiac shunt patterns in reptiles" by Filogonio et al. (2017).

    Science.gov (United States)

    Hillman, Stanley S; Hedrick, Michael S; Kohl, Zachary F

    2017-06-01

    The recent study by Filogonio et al. (2017) suggested that net cardiac shunt patterns in two species of reptiles (Trachemys scripta and Crotalus durissus) were not significantly influenced by the vascular distensibilities of the systemic and pulmonary vasculatures. This is in contrast to a previously published study (Hillman et al., 2014) in the toad (Rhinella marina) in which net cardiac shunts were predicted primarily by the physical properties of vascular distensibility rather than physiological control of resistance of the systemic and pulmonary vasculature. We analyze the data and conclusions reached by Filogonio et al. (2017) regarding the role of vascular distensibilities in determining net cardiac shunt patterns in reptiles in comparison with toads. In our view, the conclusions reached by Filogonio et al. (2017) are not supported by the data primarily because vascular distensibilities were not measured in the reptiles analyzed in their study. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

    Science.gov (United States)

    Anter, Elad; Tschabrunn, Cory M; Contreras-Valdes, Fernando M; Li, Jianqing; Josephson, Mark E

    2015-09-01

    During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Multilayer out-of-plane overlap electrostatic energy harvesting structure actuated by blood pressure for powering intra-cardiac implants

    Science.gov (United States)

    Deterre, M.; Risquez, S.; Bouthaud, B.; Dal Molin, R.; Woytasik, M.; Lefeuvre, E.

    2013-12-01

    We present an innovative multilayer out-of-plane electrostatic energy harvesting device conceived in view of scavenging energy from regular blood pressure in the heart. This concept involves the use of a deformable packaging for the implant in order to transmit the blood pressure to the electrostatic transducer. As shown in previous work, this is possible by using thin metal micro-bellows structure, providing long term hermeticity and high flexibility. The design of the electrostatic device has overcome several challenges such as the very low frequency of the mechanical excitation (1 to 2 Hz) and the small available room in the medical implant. Analytical and numerical models have been used to maximize the capacitance variation, and hence to optimize the energy conversion. We have theoretically shown that a 25-layer transducer with 6-mm diameter and 1-mm thickness could harvest at least 20 mJ per heart beat in the left ventricle under a maximum voltage of 75 V. These results show that the proposed concept is promising and could power the next generation of leadless pacemakers.

  13. A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors

    International Nuclear Information System (INIS)

    Liang, Hongbo; Fan, Man; You, Shijun; Zheng, Wandong; Zhang, Huan; Ye, Tianzhen; Zheng, Xuejing

    2017-01-01

    Highlights: •Four optical models for parabolic trough solar collectors were compared in detail. •Characteristics of Monte Carlo Method and Finite Volume Method were discussed. •A novel method was presented combining advantages of different models. •The method was suited to optical analysis of collectors with different geometries. •A new kind of cavity receiver was simulated depending on the novel method. -- Abstract: The PTC (parabolic trough solar collector) is widely used for space heating, heat-driven refrigeration, solar power, etc. The concentrated solar radiation is the only energy source for a PTC, thus its optical performance significantly affects the collector efficiency. In this study, four different optical models were constructed, validated and compared in detail. On this basis, a novel coupled method was presented by combining advantages of these models, which was suited to carry out a mass of optical simulations of collectors with different geometrical parameters rapidly and accurately. Based on these simulation results, the optimal configuration of a collector with highest efficiency can be determined. Thus, this method was useful for collector optimization and design. In the four models, MCM (Monte Carlo Method) and FVM (Finite Volume Method) were used to initialize photons distribution, as well as CPEM (Change Photon Energy Method) and MCM were adopted to describe the process of reflecting, transmitting and absorbing. For simulating reflection, transmission and absorption, CPEM was more efficient than MCM, so it was utilized in the coupled method. For photons distribution initialization, FVM saved running time and computation effort, whereas it needed suitable grid configuration. MCM only required a total number of rays for simulation, whereas it needed higher computing cost and its results fluctuated in multiple runs. In the novel coupled method, the grid configuration for FVM was optimized according to the “true values” from MCM of

  14. [An experimental study on the Chinese lung adenocarcinoma cell clone CPA-Yang1-BR with brain metastasis potency in nude mice and in vivo imaging research].

    Science.gov (United States)

    Lei, Bei; Cao, Jie; Shen, Jie; Zhao, Lanxiang; Liang, Sheng; Meng, Qinggang; Xie, Wenhui; Yang, Shunfang

    2013-08-20

    Lung cancer is the leading cause of cancer-related death in men and women. It is also the most common cause of brain metastases. A brain metastasis model is difficult to be established because of the presence of the blood-brain barrier (BBB) and the lack of optimal methods for detecting brain metastasis in nude mice. Thus, the establishment of a Chinese lung adenocarcinoma cell line and its animal model with brain metastasis potency and in vivo research is of great significance. CPA-Yang1 cells were obtained from a patient with human lung adenocarcinoma by lentiviral vector-mediated transfection of green fluorescence protein. Intracardiac inoculation of the cells was performed in nude mice, and brain metastatic lesions were detected using micro ¹⁸F FDG-PET/CT scanners, small animal in vivo imaging system for fluorescence, radionuclide and X ray fused imaging, magnetic resonance imaging (MRI) with sense body detection, and resection. The samples were divided into two parts for cell culture and histological diagnosis. The process was repeated in vivo and in vitro for four cycles to obtain a novel cell clone, CPA-Yang1-BR. A novel cell clone, CPA-Yang1-BR, was obtained with a brain metastatic rate of 50%. The use of MRI for the detection of brain metastases has obvious advantages. An experimental Chinese lung adenocarcinoma cell clone (CPA-Yang1-BR) and its animal model with brain metastasis potency in nude mice were established. MRI with sense body or micro MRI may be used as a sensitive, accurate, and noninvasive method to detect experimental brain metastases in intact live immunodeficient mice. The results of this study may serve as a technical platform for brain metastases from lung adenocarcinoma.

  15. Projection Methods

    DEFF Research Database (Denmark)

    Wagner, Falko Jens; Poulsen, Mikael Zebbelin

    1999-01-01

    When trying to solve a DAE problem of high index with more traditional methods, it often causes instability in some of the variables, and finally leads to breakdown of convergence and integration of the solution. This is nicely shown in [ESF98, p. 152 ff.].This chapter will introduce projection...... methods as a way of handling these special problems. It is assumed that we have methods for solving normal ODE systems and index-1 systems....

  16. Method Mixins

    DEFF Research Database (Denmark)

    Ernst, Erik

    2005-01-01

    The world of programming has been conquered by the procedure call mechanism, including object-oriented method invocation which is a procedure call in context of an object. This paper presents an alternative, method mixin invocations, that is optimized for flexible creation of composite behavior, ...... the call stack, e.g., to a callee's callee. The mechanism has been implemented in the programming language gbeta. Variants of the mechanism could be added to almost any imperative programming language.......The world of programming has been conquered by the procedure call mechanism, including object-oriented method invocation which is a procedure call in context of an object. This paper presents an alternative, method mixin invocations, that is optimized for flexible creation of composite behavior...

  17. Mimetic discretization methods

    CERN Document Server

    Castillo, Jose E

    2013-01-01

    To help solve physical and engineering problems, mimetic or compatible algebraic discretization methods employ discrete constructs to mimic the continuous identities and theorems found in vector calculus. Mimetic Discretization Methods focuses on the recent mimetic discretization method co-developed by the first author. Based on the Castillo-Grone operators, this simple mimetic discretization method is invariably valid for spatial dimensions no greater than three. The book also presents a numerical method for obtaining corresponding discrete operators that mimic the continuum differential and

  18. Bioluminescent human breast cancer cell lines that permit rapid and sensitive in vivo detection of mammary tumors and multiple metastases in immune deficient mice

    International Nuclear Information System (INIS)

    Jenkins, Darlene E; Hornig, Yvette S; Oei, Yoko; Dusich, Joan; Purchio, Tony

    2005-01-01

    Our goal was to generate xenograft mouse models of human breast cancer based on luciferase-expressing MDA-MB-231 tumor cells that would provide rapid mammary tumor growth; produce metastasis to clinically relevant tissues such as lymph nodes, lung, and bone; and permit sensitive in vivo detection of both primary and secondary tumor sites by bioluminescent imaging. Two clonal cell sublines of human MDA-MB-231 cells that stably expressed firefly luciferase were isolated following transfection of the parental cells with luciferase cDNA. Each subline was passaged once or twice in vivo to enhance primary tumor growth and to increase metastasis. The resulting luciferase-expressing D3H1 and D3H2LN cells were analyzed for long-term bioluminescent stability, primary tumor growth, and distal metastasis to lymph nodes, lungs, bone and soft tissues by bioluminescent imaging. Cells were injected into the mammary fat pad of nude and nude-beige mice or were delivered systemically via intracardiac injection. Metastasis was also evaluated by ex vivo imaging and histologic analysis postmortem. The D3H1 and D3H2LN cell lines exhibited long-term stable luciferase expression for up to 4–6 months of accumulative tumor growth time in vivo. Bioluminescent imaging quantified primary mammary fat pad tumor development and detected early spontaneous lymph node metastasis in vivo. Increased frequency of spontaneous lymph node metastasis was observed with D3H2LN tumors as compared with D3H1 tumors. With postmortem ex vivo imaging, we detected additional lung micrometastasis in mice with D3H2LN mammary tumors. Subsequent histologic evaluation of tissue sections from lymph nodes and lung lobes confirmed spontaneous tumor metastasis at these sites. Following intracardiac injection of the MDA-MB-231-luc tumor cells, early metastasis to skeletal tissues, lymph nodes, brain and various visceral organs was detected. Weekly in vivo imaging data permitted longitudinal analysis of metastasis at

  19. Discipline methods

    OpenAIRE

    Maria Kikila; Ioannis Koutelekos

    2012-01-01

    Child discipline is one of the most important elements of successful parenting. As discipline is defined the process that help children to learn appropriate behaviors and make good choices. Aim: The aim of the present study was to review the literature about the discipline methods. The method οf this study included bibliography research from both the review and the research literature, mainly in the pubmed data base which referred to the discipline methods. Results: In the literature it is ci...

  20. Method Mixins

    DEFF Research Database (Denmark)

    Ernst, Erik

    2002-01-01

    invocation is optimized for as-is reuse of existing behavior. Tight coupling reduces flexibility, and traditional invocation tightly couples transfer of information and transfer of control. Method mixins decouple these two kinds of transfer, thereby opening the doors for new kinds of abstraction and reuse......The procedure call mechanism has conquered the world of programming, with object-oriented method invocation being a procedure call in context of an object. This paper presents an alternative, method mixin invocations, that is optimized for flexible creation of composite behavior, where traditional....... Method mixins use shared name spaces to transfer information between caller and callee, as opposed to traditional invocation which uses parameters and returned results. This relieves a caller from dependencies on the callee, and it allows direct transfer of information further down the call stack, e...

  1. BASIC METHODS OF CLASSIFICATION AND CHARACTERISTICS OF METHODS OF PRICING IN UKRAINE

    OpenAIRE

    A. Boguslavskiy

    2014-01-01

    The article provided definitions and shows the need to use different methods of pricing of enterprises. Exposed the reasons of the absence of a universal classification of pricing methods. The approaches of different authors to classify groups of pricing methods: 1) the cost method; 2) methods with a focus on competition; 3) methods for pricing based on demand, 4) pricing with a focus on maximum profit, 5) parametric methods, 6) pricing under risk and uncertainty, etc. An improved classificat...

  2. Compositions, antibodies, asthma diagnosis methods, and methods for preparing antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hongjun; Zangar, Richard C.

    2017-01-17

    Methods for preparing an antibody are provided with the method including incorporating 3-bromo-4-hydroxy-benzoic acid into a protein to form an antigen, immunizing a mammalian host with the antigen, and recovering an antibody having an affinity for the antigen from the host. Antibodies having a binding affinity for a monohalotyrosine are provided as well as composition comprising an antibody bound with monohalotyrosine. Compositions comprising a protein having a 3-bromo-4-hydroxy-benzoic acid moiety are also provided. Methods for evaluating the severity of asthma are provide with the methods including analyzing sputum of a patient using an antibody having a binding affinity for monohalotyrosine, and measuring the amount of antibody bound to protein. Methods for determining eosinophil activity in bodily fluid are also provided with the methods including exposing bodily fluid to an antibody having a binding affinity for monohalotyrosine, and measuring the amount of bound antibody to determine the eosinophil activity.

  3. User interface inspection methods a user-centered design method

    CERN Document Server

    Wilson, Chauncey

    2014-01-01

    User Interface Inspection Methods succinctly covers five inspection methods: heuristic evaluation, perspective-based user interface inspection, cognitive walkthrough, pluralistic walkthrough, and formal usability inspections. Heuristic evaluation is perhaps the best-known inspection method, requiring a group of evaluators to review a product against a set of general principles. The perspective-based user interface inspection is based on the principle that different perspectives will find different problems in a user interface. In the related persona-based inspection, colleagues assume the

  4. galerkin's methods

    African Journals Online (AJOL)

    user

    The assumed deflection shapes used in the approximate methods such as in the Galerkin's method were normally ... to direct compressive forces Nx, was derived by Navier. [3]. ..... tend to give higher frequency and stiffness, as well as.

  5. Radiometric dating methods

    International Nuclear Information System (INIS)

    Bourdon, B.

    2003-01-01

    The general principle of isotope dating methods is based on the presence of radioactive isotopes in the geologic or archaeological object to be dated. The decay with time of these isotopes is used to determine the 'zero' time corresponding to the event to be dated. This paper recalls the general principle of isotope dating methods (bases, analytical methods, validation of results and uncertainties) and presents the methods based on natural radioactivity (Rb-Sr, Sm-Nd, U-Pb, Re-Os, K-Ar (Ar-Ar), U-Th-Ra- 210 Pb, U-Pa, 14 C, 36 Cl, 10 Be) and the methods based on artificial radioactivity with their applications. Finally, the methods based on irradiation damages (thermoluminescence, fission tracks, electron spin resonance) are briefly evoked. (J.S.)

  6. Method Mixins

    DEFF Research Database (Denmark)

    Ernst, Erik

    2002-01-01

    . Method mixins use shared name spaces to transfer information between caller and callee, as opposed to traditional invocation which uses parameters and returned results. This relieves a caller from dependencies on the callee, and it allows direct transfer of information further down the call stack, e......The procedure call mechanism has conquered the world of programming, with object-oriented method invocation being a procedure call in context of an object. This paper presents an alternative, method mixin invocations, that is optimized for flexible creation of composite behavior, where traditional...

  7. The Value of Mixed Methods Research: A Mixed Methods Study

    Science.gov (United States)

    McKim, Courtney A.

    2017-01-01

    The purpose of this explanatory mixed methods study was to examine the perceived value of mixed methods research for graduate students. The quantitative phase was an experiment examining the effect of a passage's methodology on students' perceived value. Results indicated students scored the mixed methods passage as more valuable than those who…

  8. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  9. Mapping Mixed Methods Research: Methods, Measures, and Meaning

    Science.gov (United States)

    Wheeldon, J.

    2010-01-01

    This article explores how concept maps and mind maps can be used as data collection tools in mixed methods research to combine the clarity of quantitative counts with the nuance of qualitative reflections. Based on more traditional mixed methods approaches, this article details how the use of pre/post concept maps can be used to design qualitative…

  10. DOE methods compendium

    International Nuclear Information System (INIS)

    Leasure, C.S.

    1992-01-01

    The Department of Energy (DOE) has established an analytical methods compendium development program to integrate its environmental analytical methods. This program is administered through DOE's Laboratory Management Division (EM-563). The primary objective of this program is to assemble a compendium of analytical chemistry methods of known performance for use by all DOE Environmental Restoration and Waste Management program. This compendium will include methods for sampling, field screening, fixed analytical laboratory and mobile analytical laboratory analyses. It will also include specific guidance on the proper selection of appropriate sampling and analytical methods in using specific analytical requirements

  11. The preconditioned Gauss-Seidel method faster than the SOR method

    Science.gov (United States)

    Niki, Hiroshi; Kohno, Toshiyuki; Morimoto, Munenori

    2008-09-01

    In recent years, a number of preconditioners have been applied to linear systems [A.D. Gunawardena, S.K. Jain, L. Snyder, Modified iterative methods for consistent linear systems, Linear Algebra Appl. 154-156 (1991) 123-143; T. Kohno, H. Kotakemori, H. Niki, M. Usui, Improving modified Gauss-Seidel method for Z-matrices, Linear Algebra Appl. 267 (1997) 113-123; H. Kotakemori, K. Harada, M. Morimoto, H. Niki, A comparison theorem for the iterative method with the preconditioner (I+Smax), J. Comput. Appl. Math. 145 (2002) 373-378; H. Kotakemori, H. Niki, N. Okamoto, Accelerated iteration method for Z-matrices, J. Comput. Appl. Math. 75 (1996) 87-97; M. Usui, H. Niki, T.Kohno, Adaptive Gauss-Seidel method for linear systems, Internat. J. Comput. Math. 51(1994)119-125 [10

  12. Methods of evaluating SPECT images. The usefulness of the Matsuda`s method by the Patlak plot method in children

    Energy Technology Data Exchange (ETDEWEB)

    Takaishi, Yasuko [Nippon Medical School, Tokyo (Japan); Hashimoto, Kiyoshi; Fujino, Osamu [and others

    1998-11-01

    Single photon emission computed tomography (SPECT) is a tool to study cerebral blood flow (CBF) kinetics. There are three methods of evaluating SPECT images: visual, semi-quantitative (evaluation of the radioactivity ratio of the cerebral region to the cerebellum (R/CE) or to the thalamus (R/TH)) and quantitative (Matsuda`s method by Patlak plot method using {sup 99m}Tc-hexamethylpropylene amine oxime radionuclide angiography). We evaluated SPECT images by the quantitative method in 14 patients with neurological disorders and examined the correlation of the results to those obtained by the semi-quantitative method. There was no significant correlation between the R/CE or R/TH ratio and regional CBF except two regions. The evaluation by the semi-quantitative method may have been inappropriate, probably because the cerebellar or thalamic blood flow was not constant in each case. Evaluation by the quantitative method, on the other hand, seemed to be useful not only for the comparison of CBF among normal subjects, but also in the demonstration of progressive changes of CBF in the same case. The Matsuda`s method by the Patlak plot method is suitable for examination of children, since it dose not require aortic blood sampling. (author)

  13. Transport equation solving methods

    International Nuclear Information System (INIS)

    Granjean, P.M.

    1984-06-01

    This work is mainly devoted to Csub(N) and Fsub(N) methods. CN method: starting from a lemma stated by Placzek, an equivalence is established between two problems: the first one is defined in a finite medium bounded by a surface S, the second one is defined in the whole space. In the first problem the angular flux on the surface S is shown to be the solution of an integral equation. This equation is solved by Galerkin's method. The Csub(N) method is applied here to one-velocity problems: in plane geometry, slab albedo and transmission with Rayleigh scattering, calculation of the extrapolation length; in cylindrical geometry, albedo and extrapolation length calculation with linear scattering. Fsub(N) method: the basic integral transport equation of the Csub(N) method is integrated on Case's elementary distributions; another integral transport equation is obtained: this equation is solved by a collocation method. The plane problems solved by the Csub(N) method are also solved by the Fsub(N) method. The Fsub(N) method is extended to any polynomial scattering law. Some simple spherical problems are also studied. Chandrasekhar's method, collision probability method, Case's method are presented for comparison with Csub(N) and Fsub(N) methods. This comparison shows the respective advantages of the two methods: a) fast convergence and possible extension to various geometries for Csub(N) method; b) easy calculations and easy extension to polynomial scattering for Fsub(N) method [fr

  14. Epsilon wave on an electronic loop in a case of arrhythmogenic right ventricular dysplasia with myocarditis: an updated definition of the Epsilon wave.

    Science.gov (United States)

    Fontaine, Guy Hugues; Duthoit, Guillaume; Li, Guoliang; Andreoletti, L; Gandjbakhch, Estelle; Frank, Robert

    2017-07-01

    A young man presented with a history of myocarditis with palpitations and dizziness. He had implantation of a loop recorder that showed repetitive short episodes of VT. In addition, there were fragmented potentials immediately following the large and sharp electrograms (EGMs) before as well as after episodes of VT suggesting an Epsilon wave. This signal can be observed in multiple cardiac conditions including coronary artery disease. It was originally recorded on the epicardium as well as on the endocardium. However, in ARVD it can be defined as an electric signal observed after the end of the QRS complex in the right as opposed to the left precordial leads (difference ≥ 25 ms). It can also be an aid to the diagnosis of patients with ARVD who have other signs or symptoms suggesting ARVD including episodes of myocarditis. This potential consists of a slurring at the end of the QRS complex or an independent potential after the return to the isoelectric line. It can be better observed by increasing amplification of the ECG tracing as well as double speed using the Fontaine lead system. Epsilon wave too small to be recorded on the standard ECG can be extracted by Signal Averaging ECG SAECG). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  15. A new intracavitary probe for detecting the site of origin of ectopic ventricular beats during one cardiac cycle.

    Science.gov (United States)

    Taccardi, B; Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S

    1987-01-01

    An olive-shaped probe (25 X 12 mm) with 41 evenly distributed recording electrodes on its surface was introduced into the left ventricles of seven open-chest dogs via the left atrium. In two other dogs a cylindrical probe (40 X 3 mm) was used. Electrical stimuli were delivered at 66 endocardial, midwall, or epicardial sites in the left and right ventricular walls and the septum. Mechanical stimuli were also applied at various epicardial sites. On-line mapping of equipotential contour lines on the surface of the probe invariably revealed a clear-cut potential minimum on the electrode that faced the pacing site. Time of appearance of potential minimum was 3 to 5 msec after endocardial stimuli, 10 to 25 msec for midwall and epicardial pacing, and 30 msec or more for right ventricular stimulation. Simultaneous stimulation at two sites 1.2 cm apart gave rise to two separate minima on the maps. "Pseudoisochrones" derived from electrograms recorded by the new probe were slightly less accurate in indicating the site of origin of extrasystoles. We conclude that equipotential and "isochrone" contour maps recorded from an array of semidirect electrodes, regularly distributed on the surface of an intraventricular probe, provide information on the site of origin (location and intramural depth) of ectopic paced beats in a normal dog heart.

  16. Atrioventricular node functional remodeling induced by atrial fibrillation.

    Science.gov (United States)

    Zhang, Youhua; Mazgalev, Todor N

    2012-09-01

    The atrioventricular node (AVN) plays a vital role in determining the ventricular rate during atrial fibrillation (AF). AF results in profound electrophysiological and structural remodeling in the atria as well as the sinus node. However, it is unknown whether AVN undergoes remodeling during AF. To determine whether AVN undergoes functional remodeling during AF. AVN conduction properties were studied in vitro in 9 rabbits with AF and 10 normal controls. A previously validated index of AVN dual-pathway electrophysiology, His-electrogram alternans, was used to monitor fast-pathway or slow-pathway (SP) AVN conduction in these experiments. AVN conduction properties were further studied in vivo in 7 dogs with chronic AF and 8 controls. Compared with the control rabbits, the rabbits with AF had a longer AVN conduction time (83 ± 16 ms vs 68 ± 7 ms; P AVN effective refractory period (141 ± 27 ms vs 100 ± 9 ms; P AVN effective refractory period and a slower ventricular rate during AF compared with the controls. Pronounced AVN functional electrophysiological remodeling occurs after long-term AF, which could lead to a spontaneous slowing of the ventricular rate. Furthermore, the SP dominance during AF underscores the effectiveness of its modification by ablation for ventricular rate control during AF. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Ensemble Methods

    Science.gov (United States)

    Re, Matteo; Valentini, Giorgio

    2012-03-01

    Ensemble methods are statistical and computational learning procedures reminiscent of the human social learning behavior of seeking several opinions before making any crucial decision. The idea of combining the opinions of different "experts" to obtain an overall “ensemble” decision is rooted in our culture at least from the classical age of ancient Greece, and it has been formalized during the Enlightenment with the Condorcet Jury Theorem[45]), which proved that the judgment of a committee is superior to those of individuals, provided the individuals have reasonable competence. Ensembles are sets of learning machines that combine in some way their decisions, or their learning algorithms, or different views of data, or other specific characteristics to obtain more reliable and more accurate predictions in supervised and unsupervised learning problems [48,116]. A simple example is represented by the majority vote ensemble, by which the decisions of different learning machines are combined, and the class that receives the majority of “votes” (i.e., the class predicted by the majority of the learning machines) is the class predicted by the overall ensemble [158]. In the literature, a plethora of terms other than ensembles has been used, such as fusion, combination, aggregation, and committee, to indicate sets of learning machines that work together to solve a machine learning problem [19,40,56,66,99,108,123], but in this chapter we maintain the term ensemble in its widest meaning, in order to include the whole range of combination methods. Nowadays, ensemble methods represent one of the main current research lines in machine learning [48,116], and the interest of the research community on ensemble methods is witnessed by conferences and workshops specifically devoted to ensembles, first of all the multiple classifier systems (MCS) conference organized by Roli, Kittler, Windeatt, and other researchers of this area [14,62,85,149,173]. Several theories have been

  18. Performative Schizoid Method

    DEFF Research Database (Denmark)

    Svabo, Connie

    2016-01-01

    is presented and an example is provided of a first exploratory engagement with it. The method is used in a specific project Becoming Iris, making inquiry into arts-based knowledge creation during a three month visiting scholarship at a small, independent visual art academy. Using the performative schizoid......A performative schizoid method is developed as a method contribution to performance as research. The method is inspired by contemporary research in the human and social sciences urging experimentation and researcher engagement with creative and artistic practice. In the article, the method...... method in Becoming Iris results in four audio-visual and performance-based productions, centered on an emergent theme of the scholartist as a bird in borrowed feathers. Interestingly, the moral lesson of the fable about the vain jackdaw, who dresses in borrowed peacock feathers and becomes a castout...

  19. Dimensionality Reduction Methods: Comparative Analysis of methods PCA, PPCA and KPCA

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo-Hernández

    2016-01-01

    Full Text Available The dimensionality reduction methods are algorithms mapping the set of data in subspaces derived from the original space, of fewer dimensions, that allow a description of the data at a lower cost. Due to their importance, they are widely used in processes associated with learning machine. This article presents a comparative analysis of PCA, PPCA and KPCA dimensionality reduction methods. A reconstruction experiment of worm-shape data was performed through structures of landmarks located in the body contour, with methods having different number of main components. The results showed that all methods can be seen as alternative processes. Nevertheless, thanks to the potential for analysis in the features space and the method for calculation of its preimage presented, KPCA offers a better method for recognition process and pattern extraction

  20. Development of nondestructive hybrid measuring method for three-dimensional residual stress distribution of thick welded joint. Hybrid measuring method of inherent strain method and neutron diffraction method

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Kasahara, Norifumi; Tamura, Ryota

    2012-01-01

    The measuring methods of the residual stress are classified into destructive one and nondestructive one. The inherent strain method (ISM) is destructive one. The neutron diffraction method (NDM) is nondestructive one. But the measurable depth is limited within about 20 mm and the method cannot measure the weld zone, without destruction of the object. So, in this study, the hybrid measuring method has been developed, by combining the ISM and the NDM. The theory of the hybrid method is the same as the ISM. In the analysis, the strains measured by the NDM without destruction are used. This hybrid measuring method is a true nondestructive measuring method for a thick welded joint. The applicability of the hybrid method has been verified by simulation, using a butt welded joint of thick pipes. In the simulation, the reliable order of the strains measured by the present NDM is very important, and was considered as 10 micro. The measurable regions by the present NDM were assumed. Under the above conditions, the data (the residual elastic strains assumed to be measured by the NDM) were made, and used in the ISM. As a result of such simulation, it has been cleared that the estimated residual stress has very high accuracy, if enough data are used. The required number of data is less than the ISM. (author)

  1. The surface analysis methods; Les methodes d`analyse des surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Deville, J.P. [Institut de Physique et Chimie, 67 - Strasbourg (France)

    1998-11-01

    Nowadays, there are a lot of surfaces analysis methods, each having its specificity, its qualities, its constraints (for instance vacuum) and its limits. Expensive in time and in investment, these methods have to be used deliberately. This article appeals to non specialists. It gives some elements of choice according to the studied information, the sensitivity, the use constraints or the answer to a precise question. After having recalled the fundamental principles which govern these analysis methods, based on the interaction between radiations (ultraviolet, X) or particles (ions, electrons) with matter, two methods will be more particularly described: the Auger electron spectroscopy (AES) and x-rays photoemission spectroscopy (ESCA or XPS). Indeed, they are the most widespread methods in laboratories, the easier for use and probably the most productive for the analysis of surface of industrial materials or samples submitted to treatments in aggressive media. (O.M.) 11 refs.

  2. Unstructured characteristic method embedded with variational nodal method using domain decomposition techniques

    Energy Technology Data Exchange (ETDEWEB)

    Girardi, E.; Ruggieri, J.M. [CEA Cadarache (DER/SPRC/LEPH), 13 - Saint-Paul-lez-Durance (France). Dept. d' Etudes des Reacteurs; Santandrea, S. [CEA Saclay, Dept. Modelisation de Systemes et Structures DM2S/SERMA/LENR, 91 - Gif sur Yvette (France)

    2005-07-01

    This paper describes a recently-developed extension of our 'Multi-methods,multi-domains' (MM-MD) method for the solution of the multigroup transport equation. Based on a domain decomposition technique, our approach allows us to treat the one-group equation by cooperatively employing several numerical methods together. In this work, we describe the coupling between the Method of Characteristics (integro-differential equation, unstructured meshes) with the Variational Nodal Method (even parity equation, cartesian meshes). Then, the coupling method is applied to the benchmark model of the Phebus experimental facility (Cea Cadarache). Our domain decomposition method give us the capability to employ a very fine mesh in describing a particular fuel bundle with an appropriate numerical method (MOC), while using a much large mesh size in the rest of the core, in conjunction with a coarse-mesh method (VNM). This application shows the benefits of our MM-MD approach, in terms of accuracy and computing time: the domain decomposition method allows us to reduce the Cpu time, while preserving a good accuracy of the neutronic indicators: reactivity, core-to-bundle power coupling coefficient and flux error. (authors)

  3. Unstructured characteristic method embedded with variational nodal method using domain decomposition techniques

    International Nuclear Information System (INIS)

    Girardi, E.; Ruggieri, J.M.

    2005-01-01

    This paper describes a recently-developed extension of our 'Multi-methods,multi-domains' (MM-MD) method for the solution of the multigroup transport equation. Based on a domain decomposition technique, our approach allows us to treat the one-group equation by cooperatively employing several numerical methods together. In this work, we describe the coupling between the Method of Characteristics (integro-differential equation, unstructured meshes) with the Variational Nodal Method (even parity equation, cartesian meshes). Then, the coupling method is applied to the benchmark model of the Phebus experimental facility (Cea Cadarache). Our domain decomposition method give us the capability to employ a very fine mesh in describing a particular fuel bundle with an appropriate numerical method (MOC), while using a much large mesh size in the rest of the core, in conjunction with a coarse-mesh method (VNM). This application shows the benefits of our MM-MD approach, in terms of accuracy and computing time: the domain decomposition method allows us to reduce the Cpu time, while preserving a good accuracy of the neutronic indicators: reactivity, core-to-bundle power coupling coefficient and flux error. (authors)

  4. Left ventricular thrombi: in vivo detection by indium-111 platelet imaging and two dimensional echocardiography

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.; Hamilton, G.W.; Hammermeister, K.E.; Harker, L.A.

    1981-01-01

    Indium-111 platelet imaging, which can identify sites of active intravascular platelet deposition, and two dimensional echocardiography, which can identify intracardiac masses, can both be used to detect left ventricular thrombi noninvasively. We compared these techniques in 44 men at risk for thrombi from remote transmural myocardial infarction (31 patients) or cardiomyopathy (13 patients). All 44 patients underwent platelet imaging; 35 underwent echocardiography. On platelet imaging nine patients had thrombi and onehad a possible thrombus. Of these 10 studies, none were positive at 2 hours, 5 were positive at 24 hours and all were positive 48 or 72 hours after platelet labeling. Nine of these patients underwent echocardiography, and all had an intraventricular mass. The findings on platelet scanning were negative in six patients who had positive (four patients) or equivocally positive (two patients) findings on echocardiography. All patients with thrombi detected by either noninvasive method had transmural anterior myocardial infarction with ventricular aneurysm. Of the seven patients who underwent cardiac surgery or autopsy, three had thrombi. Platelet imaging failed to identify one thrombus in a patient in whom imaging was performed only at 24 hours after labeling. There were no false positive platelet images in this group. Five of these seven patients (two with throbi, three without) underwent echocardiography; in all cases the echocardiographic findings agreed with the pathologic findings. Both platelet imaging and echocardiography detect ventricular thrombi. Platelet imaging may detect only the most hematologically active thrombi. Both techniques may help define patients at risk of embolization and may be useful for in vivo assessment of antithrombotic drugs

  5. Diagnostic Validity of RI Angiocardiography in Cardiac Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwan Yop; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1972-09-15

    The employment of gamma-ray scintillation camera with the use of short-lived radioisotopic pharmaceuticals, such as {sup 99m}Tc sodium pertechnetate, have enabled us to perform RI (radioisotopic) angiocardiography. Although conventional cardiac catheterization or angiocardiography using contrast media have been an important diagnostic tool, they may carry some risks or serious complications. The author investigated on RI angiocardiography in twelve normal and twenty five patients with cardiovascular diseases in an effort to evaluate its diagnostic value. The results obtained with this study are as follows; l. In normal subjects, the scintillation camera transit time of arm-to-right heart was found to be 2.1+-0.67 seconds, right heart-to-lung 1.5+-0.40 seconds and lung-to-left heart 3.5+-0.86 seconds. 2. Transformation or displacement of the heart and the great vessel are easily discriminated by RI angiocardiography. Both in the cases with tricuspid atresia and tetralogy of Fallot, ventricular septal defects are well recognized by sequential RI angiocardiography. 3. It is also helpful in determining the site and extent of obstruction, and estimating the postoperative course both in the cases with superior vena cava syndrome and pulmonary stenosis. 4. Pericarditis with effusion is readily diagnosed by RI angiocardiogram showing characteristic 'dead space' between intracardiac and intrapulmonary radioactivity. 5. It was found that the diagnostic accuracy of this study was 78.4%. It is concluded that above results obtained are useful and accurate enough for the diagnostic screening method for clinical practice.

  6. Diagnostic Validity of RI Angiocardiography in Cardiac Diseases

    International Nuclear Information System (INIS)

    Kim, Kwan Yop; Koh, Chang Soon; Lee, Mun Ho

    1972-01-01

    The employment of gamma-ray scintillation camera with the use of short-lived radioisotopic pharmaceuticals, such as 99m Tc sodium pertechnetate, have enabled us to perform RI (radioisotopic) angiocardiography. Although conventional cardiac catheterization or angiocardiography using contrast media have been an important diagnostic tool, they may carry some risks or serious complications. The author investigated on RI angiocardiography in twelve normal and twenty five patients with cardiovascular diseases in an effort to evaluate its diagnostic value. The results obtained with this study are as follows; l. In normal subjects, the scintillation camera transit time of arm-to-right heart was found to be 2.1±0.67 seconds, right heart-to-lung 1.5±0.40 seconds and lung-to-left heart 3.5±0.86 seconds. 2. Transformation or displacement of the heart and the great vessel are easily discriminated by RI angiocardiography. Both in the cases with tricuspid atresia and tetralogy of Fallot, ventricular septal defects are well recognized by sequential RI angiocardiography. 3. It is also helpful in determining the site and extent of obstruction, and estimating the postoperative course both in the cases with superior vena cava syndrome and pulmonary stenosis. 4. Pericarditis with effusion is readily diagnosed by RI angiocardiogram showing characteristic 'dead space' between intracardiac and intrapulmonary radioactivity. 5. It was found that the diagnostic accuracy of this study was 78.4%. It is concluded that above results obtained are useful and accurate enough for the diagnostic screening method for clinical practice.

  7. Diagnostic Validity of RI Angiocardiography in Cardiac Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwan Yop; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1972-09-15

    The employment of gamma-ray scintillation camera with the use of short-lived radioisotopic pharmaceuticals, such as {sup 99m}Tc sodium pertechnetate, have enabled us to perform RI (radioisotopic) angiocardiography. Although conventional cardiac catheterization or angiocardiography using contrast media have been an important diagnostic tool, they may carry some risks or serious complications. The author investigated on RI angiocardiography in twelve normal and twenty five patients with cardiovascular diseases in an effort to evaluate its diagnostic value. The results obtained with this study are as follows; l. In normal subjects, the scintillation camera transit time of arm-to-right heart was found to be 2.1+-0.67 seconds, right heart-to-lung 1.5+-0.40 seconds and lung-to-left heart 3.5+-0.86 seconds. 2. Transformation or displacement of the heart and the great vessel are easily discriminated by RI angiocardiography. Both in the cases with tricuspid atresia and tetralogy of Fallot, ventricular septal defects are well recognized by sequential RI angiocardiography. 3. It is also helpful in determining the site and extent of obstruction, and estimating the postoperative course both in the cases with superior vena cava syndrome and pulmonary stenosis. 4. Pericarditis with effusion is readily diagnosed by RI angiocardiogram showing characteristic 'dead space' between intracardiac and intrapulmonary radioactivity. 5. It was found that the diagnostic accuracy of this study was 78.4%. It is concluded that above results obtained are useful and accurate enough for the diagnostic screening method for clinical practice.

  8. Cardiac myxoma: A surgical experience of 38 patients over 9 years, at SSKM hospital Kolkata, India

    Directory of Open Access Journals (Sweden)

    Mohammad Shahbaaz Khan

    2013-01-01

    Full Text Available Background: Cardiac myxoma is the most common benign intracardiac tumor. We studied its clinical presentation, morbidity, mortality and recurrence following surgery over a period of 9 years. Materials and Methods: This study was performed at cardiothoracic and vascular surgery department of a tertiary level hospital of eastern India, Seth Sukhlal Karnani Memorial hospital, Institute of Post Graduate Medical Education and Research Kolkata. Near 6000 cardiac cases were operated at our center over this period. Preoperative diagnosis was made with clinical presentation and preoperative echocardiography. Complete tumor excision was done and all patients were followed up for recurrence and complications. Result: A total of 38 cases of cardiac myxoma were operated over a period from October 2002 to October 2011. Cardiac myxoma constituted about 0.6% of all cardiac cases operated at our institute. This most commonly presented at fifth decade of life. Of these, 35 cases were left atrial and 2 cases were right atrial, and 1 case was having both atrial involvements. The left atrial myxoma mostly presented as mitral stenosis and very few presented with embolic and constitutional symptoms. No death or recurrence was observed during the follow up period. Conclusion: Cardiac myxomas form a very small percentage of the cardiac cases. A high index of suspicion is essential for diagnosis. Echocardiography is the ideal diagnostic tool as also for follow-up. Immediate surgical treatment is indicated in all patients. Cardiac myxomas can be excised with a low rate of mortality and morbidity.

  9. Long term treadmill exercise performed to chronic social isolated rats regulate anxiety behavior without improving learning.

    Science.gov (United States)

    Cevik, Ozge Selin; Sahin, Leyla; Tamer, Lulufer

    2018-05-01

    The type and duration of exposure to stress is an important influence on emotional and cognitive functions. Learning is the adaptive response of the central nervous system that occurs in hippocampus which affects from environmental factors like exercise. In this study, we investigated effects of long term treadmill exercise on learning and behavior on chronic social isolated rat. Male Wistar rats (n = 32) randomly assigned into four groups: control, exercised, social isolation, social isolation + exercise during postnatal days (PNDs) 21-34. Social isolation protocol was applied during 14 days by placing rat in a cage one by one. Rats were exercised during 5 days, days were chosen randomly for overall 4 weeks (20, 30, 50, 60 min respectively). Finally, learning performance was evaluated by Morris water maze (MWM). Anxiety behavior was evaluated by Open field and elevated plus maze test. At the end of learning and behavior tests, the rats were decapitated to collect blood samples via intracardiac puncture and corticosterone analysis was performed with ELISA method. Animal weights and water consumption did not change significantly but food intake differed among groups. Corticosterone level did not change between groups. The frequency of entering to the target quadrant increased in exercised rat significantly. However, there was no difference in learning and memory in rats. Treadmill exercise reduced anxiety behavior significantly. Taken together these findings may point out that, long term treadmill exercise did not change learning and memory but reduced anxiety level of rat without changing corticosterone level. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: a preliminary study

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Boudousq, V.; Comte, F.; Eberle, M.C.; Zanca, M.; Kotzki, P.O.; Rossi, M.; Piot, C.; Raczka, F.; Davy, J.M.

    2001-01-01

    The aim of this preliminary study was to evaluate the accuracy of left and right ventricular output computed from a semi-automatic processing of tomographic radionuclide ventriculography data (TRVG) in comparison with the conventional thermodilution method. Twenty patients with various heart diseases were prospectively included in the study. Thermodilution and TRVG acquisitions were carried out on the same day for all patients. Analysis of gated blood pool slices was performed using a watershed-based segmentation algorithm. Right and left ventricular output measured by TRVG correlated well with the measurements obtained with thermodilution (r=0.94 and 0.91 with SEE=0.38 and 0.46 l/min, respectively, P<0.001). The limits of agreement for TRVG and thermodilution measurements were -0.78-1.20 l/min for the left ventricle and -0.34-1.16 l/min for the right ventricle. No significant difference was found between the results of TRVG and thermodilution with respect to left ventricular output (P=0.09). A small but significant difference was found between right ventricular output measured by TRVG and both left ventricular output measured by TRVG (mean difference=0.17 l/min, P=0.04) and thermodilution-derived cardiac output (mean difference=0.41 l/min, P=0.0001). It is concluded that the watershed-based semi-automatic segmentation of TRVG slices provides non-invasive measurements of right and left ventricular output and stroke volumes at equilibrium, in routine clinical settings. Further studies are necessary to check whether the accuracy of these measurements is good enough to permit correct assessment of intracardiac shunts. (orig.)

  11. Single Center Experience with the AngioVac Aspiration System

    Energy Technology Data Exchange (ETDEWEB)

    Salsamendi, Jason, E-mail: jsalsamendi@med.miami.edu; Doshi, Mehul, E-mail: mdoshi@med.miami.edu; Bhatia, Shivank, E-mail: sbhatia1@med.miami.edu [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department of Vascular and Interventional Radiology (United States); Bordegaray, Matthew, E-mail: matthewbordegaray@gmail.com [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department Radiology (United States); Arya, Rahul, E-mail: rahul.arya@jhsmiami.org [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department of Vascular and Interventional Radiology (United States); Morton, Connor, E-mail: cmorton@med.miami.edu [University of Miami Miller School of Medicine (United States); Narayanan, Govindarajan, E-mail: gnarayanan@med.miami.edu [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department of Vascular and Interventional Radiology (United States)

    2015-08-15

    PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and the patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.

  12. CARDIOVASCULAR RISK FACTORS IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE

    Directory of Open Access Journals (Sweden)

    Ye. D. Bazdyrev

    2014-11-01

    Full Text Available Objective: to detect previously undiagnosed arterial hypertension in patients with chronic obstructive pulmonary disease (COPD as a risk factor for cardiovascular mortality.Materials and methods. 43 patients with stage I–II of COPD and the absence of clinical signs of cardiovascular diseases were examined. Spirometry, body plethysmography and diffusing lung capacity (DLCO were included in the respiratory system assessment. The cardiovascular system was assessed with echocardiography and ambulatory blood pressure monitoring (ABPM.Results. Despite the absence of obvious signs of cardiovascular lesions (an increase of office blood pressure, intracardiac hemodynamic changes, the following cardiovascular risk factors were identified: age (58.2 ± 2.0 years, male gender, smoking, hypercholesterolemia and dyslipidemia (total cholesterol 5.9 ± 0.9 mmol / l, low density lipoproteins 3.8 ± 0.5 mmol / l, triglycerides 1.8 ± 0.2 mmol / l. Correlation analysis has revealed the relation between several respiratory parameters and the severity of dyspnea and quality of life in patients with COPD, as well as its relation with lipid levels.Conclusion. The patients with COPD have a large number of risk factors for CVD. According to ABPM data, arterial hypertension was verified in 18 (41.9 % of 43 patients with COPD at normal level of office blood pressure; moreover, 51.2 % of patients demonstrated low reduction of blood pressure during the night-time that nowadays, is considered to be a predictor of cardiovascular disease and sudden death.

  13. The effect of the timing of prenatal exposure to x-irradiation on Purkinje cell numbers in rat cerebellum

    International Nuclear Information System (INIS)

    Miki, T.; Satriotomo, I.; Matsumoto, Y.; Kuma, H.; Takeuchi, Y.; Gu

    2003-01-01

    Full text: Prenatal exposure of the developing brain to X-irradiation is known to cause various deleterious consequences. We have examined the effects of prenatal X-irradiation on the development of the cerebellum. Wistar rats were exposed to 1.5 Gy X-irradiation either on the 14, 15 or 16th day of gestation (E14, E15, E16). Sham-irradiated animals were used as controls. At seven postnatal weeks of age, male rats were deeply anesthetized and killed by intracardiac perfusion with 2.5 % glutaraldehyde in 0.1 M phosphate buffer. The unbiased stereological procedure known as the fractionator method was used to estimate the total number of Purkinje cells in the cerebellum. Body and cerebellar weights from E14 and E15, but not E16 irradiated rats showed significant deficits compared to control animals. Rats irradiated on E16 and control rats had about 285,100 - 304,800 Purkinje cells in the cerebellum. There was no significant difference between these values. However, E14 and E15 irradiated animals had about 117,500 and 196,300 Purkinje cells, respectively. These estimates were significantly different from those observed in both control and E16 irradiated rats. Given that the phase of division of Purkinje cell progenitors is mainly between E14-E15 and the phase of differentiation and migration is between E16-E20, it is concluded that the vulnerable period of the Purkinje cells to X-irradiation closely overlaps the phase of division of progenitors

  14. Paradoxical embolism: Experiences from a single center

    Directory of Open Access Journals (Sweden)

    Hong-Liang Zhang

    2017-06-01

    Full Text Available Objective: To present our treatment experiences and the follow-up data of patients with paradoxical embolism (PDE. Methods: The clinical characteristics, management, and follow-up data of all included patients who were diagnosed with PDE at Fuwai Hospital from January 1994 to October 2015 were recorded. Results: Twelve patients were included; all had a pulmonary embolism, and 8 had deep venous thrombosis. The artery embolisms involved the cerebral artery (7 patients, renal artery (2 patients, mesentery artery (2 patients, popliteal artery (1 patient, descending aorta thrombus (1 patient, and thrombus-straddled patent foramen ovale (PFO (1 patient. PFO was found in 3 cases. One patient underwent thrombectomy and PFO closure; Six patients received thrombolysis; and 3 patients were implanted with a vena cava filter. Long-term anticoagulation with warfarin was recommended for each patient. One patient died from ventricular fibrillation despite cardiopulmonary resuscitation. Eleven patients were discharged with improvements. No late mortality occurred in 8 patients with a complete follow-up of 10.6–17.7 years. One had a recurrent deep venous thrombosis. No patient had a recurrent pulmonary or arterial embolism. Two patients changed their treatment from warfarin to aspirin; others remained on warfarin. Only 1 case had an occasional gum bleeding. Conclusions: PDE treatment including thrombolysis, anticoagulation, and embolectomy should be individualized. We recommend long-term anticoagulation therapy to prevent the recurrence of PDE, especially to those with an intracardiac communication or persistent risk factors for re-thrombosis. Keywords: Paradoxical embolism, Pulmonary embolism, Deep venous thrombosis, Patent foramen ovale

  15. Focused Cardiac Ultrasound Using a Pocket-Size Device in the Emergency Room

    Directory of Open Access Journals (Sweden)

    Frederico José Neves Mancuso

    2014-12-01

    Full Text Available Background: Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions. Objective: To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care. Methods: One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated. Results: The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection. Conclusion: The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

  16. Color image definition evaluation method based on deep learning method

    Science.gov (United States)

    Liu, Di; Li, YingChun

    2018-01-01

    In order to evaluate different blurring levels of color image and improve the method of image definition evaluation, this paper proposed a method based on the depth learning framework and BP neural network classification model, and presents a non-reference color image clarity evaluation method. Firstly, using VGG16 net as the feature extractor to extract 4,096 dimensions features of the images, then the extracted features and labeled images are employed in BP neural network to train. And finally achieve the color image definition evaluation. The method in this paper are experimented by using images from the CSIQ database. The images are blurred at different levels. There are 4,000 images after the processing. Dividing the 4,000 images into three categories, each category represents a blur level. 300 out of 400 high-dimensional features are trained in VGG16 net and BP neural network, and the rest of 100 samples are tested. The experimental results show that the method can take full advantage of the learning and characterization capability of deep learning. Referring to the current shortcomings of the major existing image clarity evaluation methods, which manually design and extract features. The method in this paper can extract the images features automatically, and has got excellent image quality classification accuracy for the test data set. The accuracy rate is 96%. Moreover, the predicted quality levels of original color images are similar to the perception of the human visual system.

  17. Cooperative method development

    DEFF Research Database (Denmark)

    Dittrich, Yvonne; Rönkkö, Kari; Eriksson, Jeanette

    2008-01-01

    The development of methods tools and process improvements is best to be based on the understanding of the development practice to be supported. Qualitative research has been proposed as a method for understanding the social and cooperative aspects of software development. However, qualitative...... research is not easily combined with the improvement orientation of an engineering discipline. During the last 6 years, we have applied an approach we call `cooperative method development', which combines qualitative social science fieldwork, with problem-oriented method, technique and process improvement....... The action research based approach focusing on shop floor software development practices allows an understanding of how contextual contingencies influence the deployment and applicability of methods, processes and techniques. This article summarizes the experiences and discusses the further development...

  18. Conjugated polymer nanoparticles, methods of using, and methods of making

    KAUST Repository

    Habuchi, Satoshi; Piwonski, Hubert Marek; Michinobu, Tsuyoshi

    2017-01-01

    Embodiments of the present disclosure provide for conjugated polymer nanoparticle, method of making conjugated polymer nanoparticles, method of using conjugated polymer nanoparticle, polymers, and the like.

  19. Conjugated polymer nanoparticles, methods of using, and methods of making

    KAUST Repository

    Habuchi, Satoshi

    2017-03-16

    Embodiments of the present disclosure provide for conjugated polymer nanoparticle, method of making conjugated polymer nanoparticles, method of using conjugated polymer nanoparticle, polymers, and the like.

  20. Numerical method for time-dependent localized corrosion analysis with moving boundaries by combining the finite volume method and voxel method

    International Nuclear Information System (INIS)

    Onishi, Yuki; Takiyasu, Jumpei; Amaya, Kenji; Yakuwa, Hiroshi; Hayabusa, Keisuke

    2012-01-01

    Highlights: ► A novel numerical method to analyze time dependent localized corrosion is developed. ► It takes electromigration, mass diffusion, chemical reactions, and moving boundaries. ► Our method perfectly satisfies the conservation of mass and electroneutrality. ► The behavior of typical crevice corrosion is successfully simulated. ► Both verification and validation of our method are carried out. - Abstract: A novel numerical method for time-dependent localized corrosion analysis is presented. Electromigration, mass diffusion, chemical reactions, and moving boundaries are considered in the numerical simulation of localized corrosion of engineering alloys in an underwater environment. Our method combines the finite volume method (FVM) and the voxel method. The FVM is adopted in the corrosion rate calculation so that the conservation of mass is satisfied. A newly developed decoupled algorithm with a projection method is introduced in the FVM to decouple the multiphysics problem into the electrostatic, mass transport, and chemical reaction analyses with electroneutrality maintained. The polarization curves for the corroding metal are used as boundary conditions for the metal surfaces to calculate the corrosion rates. The voxel method is adopted in updating the moving boundaries of cavities without remeshing and mesh-to-mesh solution mapping. Some modifications of the standard voxel method, which represents the boundaries as zigzag-shaped surfaces, are introduced to generate smooth surfaces. Our method successfully reproduces the numerical and experimental results of a capillary electrophoresis problem. Furthermore, the numerical results are qualitatively consistent with the experimental results for several examples of crevice corrosion.