WorldWideScience

Sample records for international building code

  1. International building code for bamboo

    NARCIS (Netherlands)

    Janssen, J.J.A.; Kumar, Arun; Ramanuja Rao, I.V.; Sastry, Cherla

    2002-01-01

    One of the recommendations in the International Bamboo Congress and Workshop, held at Bali in 1995, requested the International Network for Bamboo and Rattan (INBAR), "to organize a task force to discuss and finalize a building code for bamboo". Consequently a draft was prepared under the title, "An

  2. The Role of the International Code Council in the U.S. Building Regukation System and Green Building Contruction

    OpenAIRE

    David Walls

    2015-01-01

    This paper will address the components of the International Code Council (ICC) as one of the most important organizations in terms of developing the model building codes for the US: the international codes. This membership-driven organization has the task of providing the building industry and all its stakeholders with the necessary regulatory documents, training, certification, plan check, product evaluation, and accreditation services to achieve safer and more sustainable building construct...

  3. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Science.gov (United States)

    2013-03-26

    ... Energy Conservation Code. International Existing Building Code. International Fire Code. International... Code. International Property Maintenance Code. International Residential Code. International Swimming Pool and Spa Code International Wildland-Urban Interface Code. International Zoning Code. ICC Standards...

  4. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Science.gov (United States)

    2010-04-16

    ... documents from ICC's Chicago District Office: International Code Council, 4051 W Flossmoor Road, Country... Energy Conservation Code. International Existing Building Code. International Fire Code. International...

  5. Building a Better Campus: An Update on Building Codes.

    Science.gov (United States)

    Madden, Michael J.

    2002-01-01

    Discusses the implications for higher education institutions in terms of facility planning, design, construction, and renovation of the move from regionally-developed model-building codes to two international sets of codes. Also addresses the new performance-based design option within the codes. (EV)

  6. A Comparative Study on Seismic Analysis of Bangladesh National Building Code (BNBC) with Other Building Codes

    Science.gov (United States)

    Bari, Md. S.; Das, T.

    2013-09-01

    Tectonic framework of Bangladesh and adjoining areas indicate that Bangladesh lies well within an active seismic zone. The after effect of earthquake is more severe in an underdeveloped and a densely populated country like ours than any other developed countries. Bangladesh National Building Code (BNBC) was first established in 1993 to provide guidelines for design and construction of new structure subject to earthquake ground motions in order to minimize the risk to life for all structures. A revision of BNBC 1993 is undergoing to make this up to date with other international building codes. This paper aims at the comparison of various provisions of seismic analysis as given in building codes of different countries. This comparison will give an idea regarding where our country stands when it comes to safety against earth quake. Primarily, various seismic parameters in BNBC 2010 (draft) have been studied and compared with that of BNBC 1993. Later, both 1993 and 2010 edition of BNBC codes have been compared graphically with building codes of other countries such as National Building Code of India 2005 (NBC-India 2005), American Society of Civil Engineering 7-05 (ASCE 7-05). The base shear/weight ratios have been plotted against the height of the building. The investigation in this paper reveals that BNBC 1993 has the least base shear among all the codes. Factored Base shear values of BNBC 2010 are found to have increased significantly than that of BNBC 1993 for low rise buildings (≤20 m) around the country than its predecessor. Despite revision of the code, BNBC 2010 (draft) still suggests less base shear values when compared to the Indian and American code. Therefore, this increase in factor of safety against the earthquake imposed by the proposed BNBC 2010 code by suggesting higher values of base shear is appreciable.

  7. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hatten, Mike [Solarc Energy Group, LLC, Seattle, WA (United States); Jones, Dennis [Group 14 Engineering, Inc., Denver, CO (United States); Cooper, Matthew [Group 14 Engineering, Inc., Denver, CO (United States)

    2017-03-24

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research is to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.

  8. Renewable Energy and Energy Efficiency Technologies in Residential Building Codes: June 15, 1998 to September 15, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Wortman, D.; Echo-Hawk, L.

    2005-02-01

    This report is an attempt to describe the building code requirements and impediments to the application of EE and RE technologies in residential buildings. Several modern model building codes were reviewed. These are representative of the codes that will be adopted by most locations in the coming years. The codes reviewed for this report include: International Residential Code, First Draft, April 1998; International Energy Conservation Code, 1998; International Mechanical Code, 1998; International Plumbing Code, 1997; International Fuel Gas Code, 1997; National Electrical Code, 1996. These codes were reviewed as to their application to (1) PV systems in buildings and building-integrated PV systems and (2) active solar domestic hot water and space-heating systems. A discussion of general code issues that impact these technologies is also included. Examples of this are solar access and sustainability.

  9. New "Risk-Targeted" Seismic Maps Introduced into Building Codes

    Science.gov (United States)

    Luco, Nicholas; Garrett, B.; Hayes, J.

    2012-01-01

    Throughout most municipalities of the United States, structural engineers design new buildings using the U.S.-focused International Building Code (IBC). Updated editions of the IBC are published every 3 years. The latest edition (2012) contains new "risk-targeted maximum considered earthquake" (MCER) ground motion maps, which are enabling engineers to incorporate a more consistent and better defined level of seismic safety into their building designs.

  10. Tribal Green Building Administrative Code Example

    Science.gov (United States)

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  11. 75 FR 20833 - Building Energy Codes

    Science.gov (United States)

    2010-04-21

    ...-0012] Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... the current model building energy codes or their equivalent. DOE is interested in better understanding... codes, Standard 90.1-2007, Energy Standard for Buildings Except Low-Rise Residential Buildings (or...

  12. Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha; Evans, Meredydd; Delgado, Alison

    2014-03-26

    s enactment, only two states and one territory out of 35 Indian states and union territories formally adopted ECBC and six additional states are in the legislative process of approving ECBC. There are several barriers that slow down the process. First, stakeholders, such as architects, developers, and state and local governments, lack awareness of building energy efficiency, and do not have enough capacity and resources to implement ECBC. Second, institution for implementing ECBC is not set up yet; ECBC is not included in local building by-laws or incorporated into the building permit process. Third, there is not a systematic approach to measuring and verifying compliance and energy savings, and thus the market does not have enough confidence in ECBC. Energy codes achieve energy savings only when projects comply with codes, yet only few countries measure compliance consistently and periodic checks often indicate poor compliance in many jurisdictions. China and the U.S. appear to be two countries with comprehensive systems in code enforcement and compliance The United States recently developed methodologies measuring compliance with building energy codes at the state level. China has an annual survey investigating code compliance rate at the design and construction stages in major cities. Like many developing countries, India has only recently begun implementing an energy code and would benefit from international experience on code compliance. In this paper, we examine lessons learned from the U.S. and China on compliance assessment and how India can apply these lessons to develop its own compliance evaluation approach. This paper also provides policy suggestions to national, state, and local governments to improve compliance and speed up ECBC implementation.

  13. Performance-based building codes: a call for injury prevention indicators that bridge health and building sectors.

    Science.gov (United States)

    Edwards, N

    2008-10-01

    The international introduction of performance-based building codes calls for a re-examination of indicators used to monitor their implementation. Indicators used in the building sector have a business orientation, target the life cycle of buildings, and guide asset management. In contrast, indicators used in the health sector focus on injury prevention, have a behavioural orientation, lack specificity with respect to features of the built environment, and do not take into account patterns of building use or building longevity. Suggestions for metrics that bridge the building and health sectors are discussed. The need for integrated surveillance systems in health and building sectors is outlined. It is time to reconsider commonly used epidemiological indicators in the field of injury prevention and determine their utility to address the accountability requirements of performance-based codes.

  14. Impacts of Model Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sivaraman, Deepak [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elliott, Douglas B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bartlett, Rosemarie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO2 emissions at the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.

  15. Country Report on Building Energy Codes in China

    Energy Technology Data Exchange (ETDEWEB)

    Shui, Bin; Evans, Meredydd; Lin, H.; Jiang, Wei; Liu, Bing; Song, Bo; Somasundaram, Sriram

    2009-04-15

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in China, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope and HVAC) for commercial and residential buildings in China.

  16. Country Report on Building Energy Codes in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Meredydd; Shui, Bin; Takagi, T.

    2009-04-15

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Japan, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Japan.

  17. Country Report on Building Energy Codes in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Shui, Bin; Evans, Meredydd; Somasundaram, Sriram

    2009-04-02

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.

  18. Country Report on Building Energy Codes in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Shui, Bin; Evans, Meredydd

    2009-04-06

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildings in Canada.

  19. Integrating Renewable Energy Requirements Into Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kaufmann, John R.; Hand, James R.; Halverson, Mark A.

    2011-07-01

    This report evaluates how and when to best integrate renewable energy requirements into building energy codes. The basic goals were to: (1) provide a rough guide of where we’re going and how to get there; (2) identify key issues that need to be considered, including a discussion of various options with pros and cons, to help inform code deliberations; and (3) to help foster alignment among energy code-development organizations. The authors researched current approaches nationally and internationally, conducted a survey of key stakeholders to solicit input on various approaches, and evaluated the key issues related to integration of renewable energy requirements and various options to address those issues. The report concludes with recommendations and a plan to engage stakeholders. This report does not evaluate whether the use of renewable energy should be required on buildings; that question involves a political decision that is beyond the scope of this report.

  20. Comparison of energy conservation building codes of Iran, Turkey, Germany, China, ISO 9164 and EN 832

    International Nuclear Information System (INIS)

    Fayaz, Rima; Kari, Behrouz M.

    2009-01-01

    To improve the energy efficiency of buildings via compliance to regulation in Iran, Code No. 19 was devised in 1991. The code lacks high level aims and objectives, addressing the characteristics of Iranian buildings. As a consequence, the code has been revised and is not completely implemented in practice, and still remains inefficient. As with any energy coding system, this code has to identify the right balance between the different energy variables for the Iranian climate and way of life. In order to assist improvements to high level objectives of Code 19, this code is compared with ISO 9164, EN 832, German regulation, TS 825 of Turkey and China's GB 50189 to understand how these have adapted international standards to national features. In order to test the appropriateness of Code 19, five case study buildings in Iran are assessed against Code 19 as well as Turkish standard TS 825 and the results are compared. The results demonstrate that Code 19 is efficient in calculations of building envelope, but it needs improvements in the areas of ventilation, gains from internal and solar sources. The paper concludes by offering suggestions for improving the code.

  1. Building codes as barriers to solar heating and cooling of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Meeker, F.O. III

    1978-04-01

    The application of building codes to solar energy systems for heating and cooling of buildings is discussed, using as typical codes the three model building codes most widely adopted by states and localities. Some potential barriers to solar energy systems are found, federal and state programs to deal with these barriers are discussed, and alternatives are suggested. To remedy this, a federal program is needed to encourage state adoption of standards and acceptance of certification of solar systems for code approval, and to encourage revisions to codes based on model legislation prepared for the federal government by the model codes groups.

  2. Kayenta Township Building & Safety Department, Tribal Green Building Code Summit Presentation

    Science.gov (United States)

    Tribal Green Building Code Summit Presentation by Kayenta Township Building & Safety Department showing how they established the building department, developed a code adoption and enforcement process, and hired staff to carry out the work.

  3. Building codes : obstacle or opportunity?

    Science.gov (United States)

    Alberto Goetzl; David B. McKeever

    1999-01-01

    Building codes are critically important in the use of wood products for construction. The codes contain regulations that are prescriptive or performance related for various kinds of buildings and construction types. A prescriptive standard might dictate that a particular type of material be used in a given application. A performance standard requires that a particular...

  4. National Tribal Building Codes Summit

    Science.gov (United States)

    National Tribal Building Codes summit statement developed to support tribes interested in adopting green and culturally-appropriate building systems to ensure safe, sustainable, affordable, and culturally-appropriate buildings on tribal lands.

  5. Building Energy Codes: Policy Overview and Good Practices

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Sadie [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-19

    Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

  6. Potential Job Creation in Nevada as a Result of Adopting New Residential Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Michael J.; Niemeyer, Jackie M.

    2013-09-01

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levels of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.

  7. Potential Job Creation in Tennessee as a Result of Adopting New Residential Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Michael J.; Niemeyer, Jackie M.

    2013-09-01

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levels of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.

  8. Potential Job Creation in Minnesota as a Result of Adopting New Residential Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Michael J.; Niemeyer, Jackie M.

    2013-09-01

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levels of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.

  9. 76 FR 64931 - Building Energy Codes Cost Analysis

    Science.gov (United States)

    2011-10-19

    ...-0046] Building Energy Codes Cost Analysis AGENCY: Office of Energy Efficiency and Renewable Energy... reopening of the time period for submitting comments on the request for information on Building Energy Codes... the request for information on Building Energy Code Cost Analysis and provide docket number EERE-2011...

  10. Country Report on Building Energy Codes in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark A.; Shui, Bin; Evans, Meredydd

    2009-04-30

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in U.S., including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildings in the U.S.

  11. Potential Job Creation in Rhode Island as a Result of Adopting New Residential Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Michael J.; Niemeyer, Jackie M.

    2013-09-01

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levels of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.

  12. Building Standards and Codes for Energy Conservation

    Science.gov (United States)

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  13. 49 CFR 41.120 - Acceptable model codes.

    Science.gov (United States)

    2010-10-01

    ... 1991 International Conference of Building Officials (ICBO) Uniform Building Code, published by the... Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code, published by the Building Officials and Code Administrators, 4051 West Flossmoor Rd., Country Club Hills...

  14. Office of Codes and Standards resource book. Section 1, Building energy codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1995-01-01

    The US Department of Energy`s (DOE`s) Office of Codes and Standards has developed this Resource Book to provide: A discussion of DOE involvement in building codes and standards; a current and accurate set of descriptions of residential, commercial, and Federal building codes and standards; information on State contacts, State code status, State building construction unit volume, and State needs; and a list of stakeholders in the building energy codes and standards arena. The Resource Book is considered an evolving document and will be updated occasionally. Users are requested to submit additional data (e.g., more current, widely accepted, and/or documented data) and suggested changes to the address listed below. Please provide sources for all data provided.

  15. Building energy, building leadership : recommendations for the adoption, development, and implementation of a commercial building energy code in Manitoba

    Energy Technology Data Exchange (ETDEWEB)

    Akerstream, T. [Manitoba Hydro, Winnipeg, MB (Canada); Allard, K. [City of Thompson, Thompson, MB (Canada); Anderson, N.; Beacham, D. [Manitoba Office of the Fire Commissioner, Winnipeg, MB (Canada); Andrich, R. [The Forks North Portage Partnership, MB (Canada); Auger, A. [Natural Resources Canada, Ottawa, ON (Canada). Office of Energy Efficiency; Downs, R.G. [Shindico Realty Inc., Winnipeg, MB (Canada); Eastwood, R. [Number Ten Architectural Group, Winnipeg, MB (Canada); Hewitt, C. [SMS Engineering Ltd., Winnipeg, MB (Canada); Joshi, D. [City of Winnipeg, Winnipeg, MB (Canada); Klassen, K. [Manitoba Dept. of Energy Science and Technology, Winnipeg, MB (Canada); Phillips, B. [Unies Ltd., Winnipeg, MB (Canada); Wiebe, R. [Ben Wiebe Construction Ltd., Winnipeg, MB (Canada); Woelk, D. [Bockstael Construction Ltd., Winnipeg, MB (Canada); Ziemski, S. [CREIT Management LLP, Winnipeg, MB (Canada)

    2006-09-15

    This report presented a strategy and a set of recommendations for the adoption, development and implementation of an energy code for new commercial construction in Manitoba. The report was compiled by an advisory committee comprised of industry representatives and government agency representatives. Recommendations were divided into 4 categories: (1) advisory committee recommendations; (2) code adoption recommendations; (3) code development recommendations; and (4) code implementation recommendations. It was suggested that Manitoba should adopt an amended version of the Model National Energy Code for Buildings (1997) as a regulation under the Buildings and Mobile Homes Act. Participation in a national initiative to update the Model National Energy Code for Buildings was also advised. It was suggested that the energy code should be considered as the first step in a longer-term process towards a sustainable commercial building code. However, the code should be adopted within the context of a complete market transformation approach. Other recommendations included: the establishment of a multi-stakeholder energy code task group; the provision of information and technical resources to help build industry capacity; the establishment of a process for energy code compliance; and an ongoing review of the energy code to assess impacts and progress. Supplemental recommendations for future discussion included the need for integrated design by building design teams in Manitoba; the development of a program to provide technical assistance to building design teams; and collaboration between post-secondary institutions to develop and deliver courses on integrated building design to students and professionals. 17 refs.

  16. The Cost of Enforcing Building Energy Codes: Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Alison [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vine, Ed [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sturges, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rosenquist, Greg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    The purpose of this literature review is to summarize key findings regarding the costs associated with enforcing building energy code compliance—primarily focusing on costs borne by local government. The review takes into consideration over 150 documents that discuss, to some extent, code enforcement. This review emphasizes those documents that specifically focus on costs associated with energy code enforcement. Given the low rates of building energy code compliance that have been reported in existing studies, as well as the many barriers to both energy code compliance and enforcement, this study seeks to identify the costs of initiatives to improve compliance and enforcement. Costs are reported primarily as presented in the original source. Some costs are given on a per home or per building basis, and others are provided for jurisdictions of a certain size. This literature review gives an overview of state-based compliance rates, barriers to code enforcement, and U.S. Department of Energy (DOE) and key stakeholder involvement in improving compliance with building energy codes. In addition, the processes and costs associated with compliance and enforcement of building energy codes are presented. The second phase of this study, which will be presented in a different report, will consist of surveying 34 experts in the building industry at the national and state or local levels in order to obtain additional cost information, building on the findings from the first phase, as well as recommendations for where to most effectively spend money on compliance and enforcement.

  17. Building codes: An often overlooked determinant of health.

    Science.gov (United States)

    Chauvin, James; Pauls, Jake; Strobl, Linda

    2016-05-01

    Although the vast majority of the world's population spends most of their time in buildings, building codes are not often thought of as 'determinants of health'. The standards that govern the design, construction, and use of buildings affect our health, security, safety, and well-being. This is true for dwellings, schools, and universities, shopping centers, places of recreation, places of worship, health-care facilities, and workplaces. We urge proactive engagement by the global public health community in developing these codes, and in the design and implementation of health protection and health promotion activities intended to reduce the risk of injury, disability, and death, particularly when due to poor building code adoption/adaption, application, and enforcement.

  18. 1995 building energy codes and standards workshops: Summary and documentation

    Energy Technology Data Exchange (ETDEWEB)

    Sandahl, L.J.; Shankle, D.L.

    1996-02-01

    During the spring of 1995, Pacific Northwest National Laboratory (PNNL) conducted four two-day Regional Building Energy Codes and Standards workshops across the US. Workshops were held in Chicago, Denver, Rhode Island, and Atlanta. The workshops were designed to benefit state-level officials including staff of building code commissions, energy offices, public utility commissions, and others involved with adopting/updating, implementing, and enforcing building energy codes in their states. The workshops provided an opportunity for state and other officials to learn more about residential and commercial building energy codes and standards, the role of the US Department of Energy and the Building Standards and Guidelines Program at Pacific Northwest National Laboratory, Home Energy Rating Systems (HERS), Energy Efficient Mortgages (EEM), training issues, and other topics related to the development, adoption, implementation, and enforcement of building energy codes. Participants heard success stories, got tips on enforcement training, and received technical support materials. In addition to receiving information on the above topics, workshop participants had an opportunity to provide input on code adoption issues, building industry training issues, building design issues, and exemplary programs across the US. This paper documents the workshop planning, findings, and follow-up processes.

  19. Building Codes and Regulations.

    Science.gov (United States)

    Fisher, John L.

    The hazard of fire is of great concern to libraries due to combustible books and new plastics used in construction and interiors. Building codes and standards can offer architects and planners guidelines to follow but these standards should be closely monitored, updated, and researched for fire prevention. (DS)

  20. An Examination of the Performance Based Building Code on the Design of a Commercial Building

    Directory of Open Access Journals (Sweden)

    John Greenwood

    2012-11-01

    Full Text Available The Building Code of Australia (BCA is the principal code under which building approvals in Australia are assessed. The BCA adopted performance-based solutions for building approvals in 1996. Performance-based codes are based upon a set of explicit objectives, stated in terms of a hierarchy of requirements beginning with key general objectives. With this in mind, the research presented in this paper aims to analyse the impact of the introduction of the performance-based code within Western Australia to gauge the effect and usefulness of alternative design solutions in commercial construction using a case study project. The research revealed that there are several advantages to the use of alternative designs and that all parties, in general, are in favour of the performance-based building code of Australia. It is suggested that change in the assessment process to streamline the alternative design path is needed for the greater use of the performance-based alternative. With appropriate quality control measures, minor variations to the deemed-to-satisfy provisions could easily be managed by the current and future building surveying profession.

  1. Energy Efficiency Requirements in Building Codes, Energy Efficiency Policies for New Buildings. IEA Information Paper

    Energy Technology Data Exchange (ETDEWEB)

    Laustsen, Jens

    2008-03-15

    The aim of this paper is to describe and analyse current approaches to encourage energy efficiency in building codes for new buildings. Based on this analysis the paper enumerates policy recommendations for enhancing how energy efficiency is addressed in building codes and other policies for new buildings. This paper forms part of the IEA work for the G8 Gleneagles Plan of Action. These recommendations reflect the study of different policy options for increasing energy efficiency in new buildings and examination of other energy efficiency requirements in standards or building codes, such as energy efficiency requirements by major renovation or refurbishment. In many countries, energy efficiency of buildings falls under the jurisdiction of the federal states. Different standards cover different regions or climatic conditions and different types of buildings, such as residential or simple buildings, commercial buildings and more complicated high-rise buildings. There are many different building codes in the world and the intention of this paper is not to cover all codes on each level in all countries. Instead, the paper details different regions of the world and different ways of standards. In this paper we also evaluate good practices based on local traditions. This project does not seek to identify one best practice amongst the building codes and standards. Instead, different types of codes and different parts of the regulation have been illustrated together with examples on how they have been successfully addressed. To complement this discussion of efficiency standards, this study illustrates how energy efficiency can be improved through such initiatives as efficiency labelling or certification, very best practice buildings with extremely low- or no-energy consumption and other policies to raise buildings' energy efficiency beyond minimum requirements. When referring to the energy saving potentials for buildings, this study uses the analysis of recent IEA

  2. The Influence of Building Codes on Recreation Facility Design.

    Science.gov (United States)

    Morrison, Thomas A.

    1989-01-01

    Implications of building codes upon design and construction of recreation facilities are investigated (national building codes, recreation facility standards, and misperceptions of design requirements). Recreation professionals can influence architectural designers to correct past deficiencies, but they must understand architectural and…

  3. Lost opportunities: Modeling commercial building energy code adoption in the United States

    International Nuclear Information System (INIS)

    Nelson, Hal T.

    2012-01-01

    This paper models the adoption of commercial building energy codes in the US between 1977 and 2006. Energy code adoption typically results in an increase in aggregate social welfare by cost effectively reducing energy expenditures. Using a Cox proportional hazards model, I test if relative state funding, a new, objective, multivariate regression-derived measure of government capacity, as well as a vector of control variables commonly used in comparative state research, predict commercial building energy code adoption. The research shows little political influence over historical commercial building energy code adoption in the sample. Colder climates and higher electricity prices also do not predict more frequent code adoptions. I do find evidence of high government capacity states being 60 percent more likely than low capacity states to adopt commercial building energy codes in the following year. Wealthier states are also more likely to adopt commercial codes. Policy recommendations to increase building code adoption include increasing access to low cost capital for the private sector and providing noncompetitive block grants to the states from the federal government. - Highlights: ► Model the adoption of commercial building energy codes from 1977–2006 in the US. ► Little political influence over historical building energy code adoption. ► High capacity states are over 60 percent more likely than low capacity states to adopt codes. ► Wealthier states are more likely to adopt commercial codes. ► Access to capital and technical assistance is critical to increase code adoption.

  4. 24 CFR 200.926a - Residential building code comparison items.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Residential building code comparison items. 200.926a Section 200.926a Housing and Urban Development Regulations Relating to Housing and... § 200.926a Residential building code comparison items. HUD will review each local and State code...

  5. SAFETY IN THE DESIGN OF SCIENCE LABORATORIES AND BUILDING CODES.

    Science.gov (United States)

    HOROWITZ, HAROLD

    THE DESIGN OF COLLEGE AND UNIVERSITY BUILDINGS USED FOR SCIENTIFIC RESEARCH AND EDUCATION IS DISCUSSED IN TERMS OF LABORATORY SAFETY AND BUILDING CODES AND REGULATIONS. MAJOR TOPIC AREAS ARE--(1) SAFETY RELATED DESIGN FEATURES OF SCIENCE LABORATORIES, (2) LABORATORY SAFETY AND BUILDING CODES, AND (3) EVIDENCE OF UNSAFE DESIGN. EXAMPLES EMPHASIZE…

  6. A long-term, integrated impact assessment of alternative building energy code scenarios in China

    International Nuclear Information System (INIS)

    Yu, Sha; Eom, Jiyong; Evans, Meredydd; Clarke, Leon

    2014-01-01

    China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO 2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, is developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13–22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement. - Highlights: • We assessed long-term impacts of building codes and climate policy using GCAM. • Building energy codes would reduce Chinese building energy use by 13–22%. • The impacts of codes on building energy use vary by climate region and sub-sector

  7. Comparing internal and external run-time coupling of CFD and building energy simulation software

    NARCIS (Netherlands)

    Djunaedy, E.; Hensen, J.L.M.; Loomans, M.G.L.C.

    2004-01-01

    This paper describes a comparison between internal and external run-time coupling of CFD and building energy simulation software. Internal coupling can be seen as the "traditional" way of developing software, i.e. the capabilities of existing software are expanded by merging codes. With external

  8. use of the RESRAD-BUILD code to calculate building surface contamination limits

    International Nuclear Information System (INIS)

    Faillace, E.R.; LePoire, D.; Yu, C.

    1996-01-01

    Surface contamination limits in buildings were calculated for 226 Ra, 230 Th, 232 Th, and natural uranium on the basis of 1 mSv y -1 (100 mrem y -1 ) dose limit. The RESRAD-BUILD computer code was used to calculate these limits for two scenarios: building occupancy and building renovation. RESRAD-BUILD is a pathway analysis model designed to evaluate the potential radiological dose incurred by individuals working or living inside a building contaminated with radioactive material. Six exposure pathways are considered in the RESRAD-BUILD code: (1) external exposure directly from the source; (2) external exposure from materials deposited on the floor; (3) external exposure due to air submersion; (4) inhalation of airborne radioactive particles; (5) inhalation of aerosol indoor radon progeny; and (6) inadvertent ingestion of radioactive material, either directly from the sources or from materials deposited on the surfaces. The code models point, line, area, and volume sources and calculates the effects of radiation shielding, building ventilation, and ingrowth of radioactive decay products. A sensitivity analysis was performed to determine how variations in input parameters would affect the surface contamination limits. In most cases considered, inhalation of airborne radioactive particles was the primary exposure pathway. However, the direct external exposure contribution from surfaces contaminated with 226 Ra was in some cases the dominant pathway for building occupancy depending on the room size, ventilation rates, and surface release fractions. The surface contamination limits are most restrictive for 232 Th, followed by 230 Th, natural uranium, and 226 Ra. The results are compared with the surface contamination limits in the Nuclear Regulatory Commission's Regulatory Guide 1.86, which are most restrictive for 226 Ra and 230 Th, followed by 232 Th, and are least restrictive for natural uranium

  9. Verification of RESRAD-build computer code, version 3.1

    International Nuclear Information System (INIS)

    2003-01-01

    RESRAD-BUILD is a computer model for analyzing the radiological doses resulting from the remediation and occupancy of buildings contaminated with radioactive material. It is part of a family of codes that includes RESRAD, RESRAD-CHEM, RESRAD-RECYCLE, RESRAD-BASELINE, and RESRAD-ECORISK. The RESRAD-BUILD models were developed and codified by Argonne National Laboratory (ANL); version 1.5 of the code and the user's manual were publicly released in 1994. The original version of the code was written for the Microsoft DOS operating system. However, subsequent versions of the code were written for the Microsoft Windows operating system. The purpose of the present verification task (which includes validation as defined in the standard) is to provide an independent review of the latest version of RESRAD-BUILD under the guidance provided by ANSI/ANS-10.4 for verification and validation of existing computer programs. This approach consists of a posteriori V and V review which takes advantage of available program development products as well as user experience. The purpose, as specified in ANSI/ANS-10.4, is to determine whether the program produces valid responses when used to analyze problems within a specific domain of applications, and to document the level of verification. The culmination of these efforts is the production of this formal Verification Report. The first step in performing the verification of an existing program was the preparation of a Verification Review Plan. The review plan consisted of identifying: Reason(s) why a posteriori verification is to be performed; Scope and objectives for the level of verification selected; Development products to be used for the review; Availability and use of user experience; and Actions to be taken to supplement missing or unavailable development products. The purpose, scope and objectives for the level of verification selected are described in this section of the Verification Report. The development products that were used

  10. The Cost of Enforcing Building Energy Codes: Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Alison [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vine, Ed [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-10-15

    The purpose of this study is to present key findings regarding costs associated with enforcing building energy code compliance–primarily focusing on costs borne by local government. Building codes, if complied with, have the ability to save a significant amount of energy. However, energy code compliance rates have been significantly lower than 100%. Renewed interest in building energy codes has focused efforts on increasing compliance, particularly as a result of the 2009 American Recovery and Reinvestment Act (ARRA) requirement that in order for states to receive additional energy grants, they must have “a plan for the jurisdiction achieving compliance with the building energy code…in at least 90 percent of new and renovated residential and commercial building space” by 2017 (Public Law 111-5, Section 410(2)(C)). One study by the Institute for Market Transformation (IMT) estimated the costs associated with reaching 90% compliance to be $810 million, or $610 million in additional funding over existing expenditures, a non-trivial value. [Majersik & Stellberg 2010] In this context, Lawrence Berkeley National Laboratory (LBNL) conducted a study to better pinpoint the costs of enforcement through a two-phase process.

  11. Economic aspects and models for building codes

    DEFF Research Database (Denmark)

    Bonke, Jens; Pedersen, Dan Ove; Johnsen, Kjeld

    It is the purpose of this bulletin to present an economic model for estimating the consequence of new or changed building codes. The object is to allow comparative analysis in order to improve the basis for decisions in this field. The model is applied in a case study.......It is the purpose of this bulletin to present an economic model for estimating the consequence of new or changed building codes. The object is to allow comparative analysis in order to improve the basis for decisions in this field. The model is applied in a case study....

  12. Policy Pathways: Modernising Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-01

    Buildings are the largest consumers of energy worldwide and will continue to be a source of increasing energy demand in the future. Globally, the sector’s final energy consumption doubled between 1971 and 2010 to reach 2 794 million tonnes of oil equivalent (Mtoe), driven primarily by population increase and economic growth. Under current policies, the global energy demand of buildings is projected by the IEA experts to grow by an additional 838 Mtoe by 2035 compared to 2010. The challenges of the projected increase of energy consumption due to the built environment vary by country. In IEA member countries, much of the future buildings stock is already in place, and so the main challenge is to renovate existing buildings stock. In non-IEA countries, more than half of the buildings stock needed by 2050 has yet to be built. The IEA and the UNDP partnered to analyse current practices in the design and implementation of building energy codes. The aim is to consolidate existing efforts and to encourage more attention to the role of the built environment in a low-carbon and climate-resilient world. This joint IEA-UNDP Policy Pathway aims to share lessons learned between IEA member countries and non-IEA countries. The objective is to spread best practices, limit pressures on global energy supply, improve energy security, and contribute to environmental sustainability. Part of the IEA Policy Pathway series, Modernising building energy codes to secure our global energy future sets out key steps in planning, implementation, monitoring and evaluation. The Policy Pathway series aims to help policy makers implement the IEA 25 Energy Efficiency Policy Recommendations endorsed by IEA Ministers (2011).

  13. A MODEL BUILDING CODE ARTICLE ON FALLOUT SHELTERS WITH RECOMMENDATIONS FOR INCLUSION OF REQUIREMENTS FOR FALLOUT SHELTER CONSTRUCTION IN FOUR NATIONAL MODEL BUILDING CODES.

    Science.gov (United States)

    American Inst. of Architects, Washington, DC.

    A MODEL BUILDING CODE FOR FALLOUT SHELTERS WAS DRAWN UP FOR INCLUSION IN FOUR NATIONAL MODEL BUILDING CODES. DISCUSSION IS GIVEN OF FALLOUT SHELTERS WITH RESPECT TO--(1) NUCLEAR RADIATION, (2) NATIONAL POLICIES, AND (3) COMMUNITY PLANNING. FALLOUT SHELTER REQUIREMENTS FOR SHIELDING, SPACE, VENTILATION, CONSTRUCTION, AND SERVICES SUCH AS ELECTRICAL…

  14. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...

  15. 78 FR 55245 - Activities and Methodology for Assessing Compliance With Building Energy Codes

    Science.gov (United States)

    2013-09-10

    ...-0036] Activities and Methodology for Assessing Compliance With Building Energy Codes AGENCY: Office of... available to states to evaluate compliance with building energy codes and general approaches towards... building energy codes and general approaches towards compliance. The comment period ended on September 5...

  16. Radon Protection in the Technical Building Code

    International Nuclear Information System (INIS)

    Frutos, B.; Garcia, J. P.; Martin, J. L.; Olaya, M.; Serrano, J I.; Suarez, E.; Fernandez, J. A.; Rodrigo, F.

    2003-01-01

    Building construction in areas with high radon gas contamination in land requires the incorporation of certain measures in order to prevent the accumulation of this gas on the inside of buildings. These measures should be considered primarily in the design and construction phases and should take the area of the country into consideration where the construction will take place depending on the potential risk of radon entrance. Within the Technical Building Code, radon protection has been considered through general classification of the country and specific areas where building construction is to take place, in different risk categories and in the introduction of building techniques appropriate for each area. (Author) 17 refs

  17. Code Compliant School Buildings Boost Student Achievement

    Directory of Open Access Journals (Sweden)

    Ronald B. Lumpkin

    2014-11-01

    Full Text Available Much of the focus in the literature in raising student achievement has included parental involvement, principal leadership, quality of instruction, students’ socioeconomic status, curriculum, and use of technology. Limited empirical research relates the condition of the school building as a variable that affects student achievement. Furthermore, there is no research that has examined the impact of building codes on achievement outcomes in the state of Florida. This research determined whether academic achievement of 4th-, 8th-, 9th-, and 10th-grade students as measured by the mathematics and reading subtests of the Florida Comprehensive Achievement Test (FCAT increased in new school buildings compliant to the 2000 Florida State Requirements for Educational Facilities. A causal-comparative design determined whether the independent variables, old and new school building influenced student achievement as measured by students’ FCAT mathematics and reading subtest scores. The control group was two cohorts of 4th-, 8th-, 9th-, and 10th-grade students who attended school in old buildings. The experimental group was two cohorts of 4th-, 8th-, 9th-, and 10th-grade students who attended school in new buildings. Transition from an old school into a new school was the treatment. Two hypotheses were formulated for testing and the research question for the inquiry was whether the percentage of students passing the FCAT mathematics and reading subtests increases after transitioning from an old school building into a new 2000 UBC (Uniform Building Code compliant facility.

  18. 76 FR 57982 - Building Energy Codes Cost Analysis

    Science.gov (United States)

    2011-09-19

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2011-BT-BC-0046] Building Energy Codes Cost Analysis Correction In notice document 2011-23236 beginning on page...-23236 Filed 9-16-11; 8:45 am] BILLING CODE 1505-01-P ...

  19. International codes concerning the security of radioisotopes

    International Nuclear Information System (INIS)

    Kusama, Keiji

    2013-01-01

    Explained is the title subject with international and Japanese official argument or publications and actions, where the security is defined as protection of sealed and unsealed radioisotopes (RI) from malicious acts. IAEA worked out the Code of Conduct on the Safety and Security of Radioactive Sources in 2004 based on its preceding argument and with the turning point of the terrorism 3.11 (2001), and Nuclear Security Recommendations on radioactive material and associated facilities (2011), for whose prerequisite, Security of radioactive sources: implementing guide (2009) and Security in the transport of radioactive material (2008) had been drawn up. The Code of Conduct indicates the security system to regulate the sealed sources that each nation has to build up through legislation, setup of regulatory agency, registration of the sources, provision of concerned facilities with radiation protection, etc. For attaining this purpose, IAEA defined Guidance on the Import and Export of Radioactive Sources (2005, 2012), Categorization of radioactive sources (2005) and Dangerous quantities of radioactive material (D-VALUES) (2006). For updating the related matters, IAEA holds international conferences somewhere in the world every year. The Nuclear Security Recommendations indicate the nation's responsibility of building up and maintaining the security system above with well-balanced measures between the safe and secure use of RI without the invalid inhibition of their usage. Japan government worked out the concept essential for ensuring the nuclear security in Sep. 2011, in which for RI, defined were the risk and benefit in use and security, and securing role of the present legal systems concerning the safety handling and objective RI involved in their registration system. Securing measures of RI in such usage as medical and industrial aids must be of advanced usefulness and safety in harmony with activities of other countries. (T.T)

  20. Pinoleville Pomo Nation Tribal Green Building Code

    Science.gov (United States)

    The Pinoleville Pomo Nation (PPN) worked with the U.S. Environmental Protection Agency (EPA) and the Development Center for Appropriate Technology (DCAT) to create this framework for tribal building codes.

  1. A Perspective of Energy Codes and Regulations for the Buildings of the Future

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael [Pacific Northwest National Laboratory,2032 Todd Street,Eugene, OR 97405e-mail: michael.rosenberg@pnnl.gov; Jonlin, Duane [Seattle Department ofConstruction and Inspections,P.O. Box 34019,Seattle, WA 98124e-mail: duane.jonlin@seattle.gov; Nadel, Steven [American Council for anEnergy-Efficient Economy,529 14th Street NW #600,Washington, DC 20045e-mail: snadel@aceee.org

    2016-10-13

    Today’s building energy codes focus on prescriptive requirements for features of buildings that are directly controlled by the design and construction teams and verifiable by municipal inspectors. Although these code requirements have had a significant impact, they fail to influence a large slice of the building energy use pie – including not only miscellaneous plug loads, cooking equipment and commercial/industrial processes, but the maintenance and optimization of the code-mandated systems as well. Currently, code compliance is verified only through the end of construction, and there are no limits or consequences for the actual energy use in an occupied building. In the future, our suite of energy regulations will likely expand to include building efficiency, energy use or carbon emission budgets over their full life cycle. Intelligent building systems, extensive renewable energy, and a transition from fossil fuel to electric heating systems will likely be required to meet ultra-low-energy targets. This paper lays out the authors’ perspectives on how buildings may evolve over the course of the 21st century and the roles that codes and regulations will play in shaping those buildings of the future.

  2. Net Zero Energy Buildings

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Bourrelle, Julien S.; Gustavsen, Arild

    2010-01-01

    and identify possible renewable energy supply options which may be considered in calculations. Finally, the gap between the methodology proposed by each organisation and their respective national building code is assessed; providing an overview of the possible changes building codes will need to undergo......The international cooperation project IEA SHC Task 40 / ECBCS Annex 52 “Towards Net Zero Energy Solar Buildings”, attempts to develop a common understanding and to set up the basis for an international definition framework of Net Zero Energy Buildings (Net ZEBs). The understanding of such buildings...

  3. Cost and code study of underground building: a report to the Minnesota Energy Agency

    Energy Technology Data Exchange (ETDEWEB)

    Sterling, R L

    1979-11-01

    The rapidly intensifying interest in the possible energy savings and environmental and land-use benefits associated with underground buildings has led increasing numbers of people to question restrictions that existing building codes place on underground construction and to make cost comparisons between underground structures and more-conventional buildings. Information in this report on earth-sheltered houses covers public policy issues (building code restrictions, taxation, insurance) and residential construction costs (cost breakdowns, general factors affecting costs, and life-cycle costs). The report also deals with regulatory and insurance issues (building codes, fire protection, insurance provisions) and construction costs for large underground buildings. The report recommends that: (1) the Minnesota Energy Agency consult with the Building Code Division of the Department of Administration on HUD Minimum Property Standards to examine the possibility of modifying several building-code requirements that affect earth-sheltered housing design; (2) HUD Minimum Property Standards be brought into line with the major building codes on the question of optional mechanical ventilation in houses; (3) model ordinances concerning setbacks, basement house provisions, and minimum square footage provisions to be drafted; (4) legal questions concerning the separation of ownership of the surface from that subsurface space be resolved; (5) questions concerning taxation of mined space be resolved; and (6) a life-cost inventory of underground residences and buildings in Minnesota be compiled.

  4. Energy Efficiency Program Administrators and Building Energy Codes

    Science.gov (United States)

    Explore how energy efficiency program administrators have helped advance building energy codes at federal, state, and local levels—using technical, institutional, financial, and other resources—and discusses potential next steps.

  5. Updates to building-code maps for the 2015 NEHRP recommended seismic provisions

    Science.gov (United States)

    Luco, Nicolas; Bachman, Robert; Crouse, C.B; Harris, James R.; Hooper, John D.; Kircher, Charles A.; Caldwell, Phillp; Rukstales, Kenneth S.

    2015-01-01

    With the 2014 update of the U.S. Geological Survey (USGS) National Seismic Hazard Model (NSHM) as a basis, the Building Seismic Safety Council (BSSC) has updated the earthquake ground motion maps in the National Earthquake Hazards Reduction Program (NEHRP) Recommended Seismic Provisions for New Buildings and Other Structures, with partial funding from the Federal Emergency Management Agency. Anticipated adoption of the updated maps into the American Society of Civil Engineers Minimum Design Loads for Building and Other Structures and the International Building and Residential Codes is underway. Relative to the ground motions in the prior edition of each of these documents, most of the updated values are within a ±20% change. The larger changes are, in most cases, due to the USGS NSHM updates, reasons for which are given in companion publications. In some cases, the larger changes are partly due to a BSSC update of the slope of the fragility curve that is used to calculate the risk-targeted ground motions, and/or the introduction by BSSC of a quantitative definition of “active faults” used to calculate deterministic ground motions.

  6. Building climate change into infrastructure codes and standards

    International Nuclear Information System (INIS)

    Auld, H.; Klaasen, J.; Morris, R.; Fernandez, S.; MacIver, D.; Bernstein, D.

    2009-01-01

    'Full text:' Building codes and standards and the climatic design values embedded within these legal to semi-legal documents have profound safety, health and economic implications for Canada's infrastructure systems. The climatic design values that have been used for the design of almost all of today's more than $5.5 Trillion in infrastructure are based on historical climate data and assume that the extremes of the past will represent future conditions. Since new infrastructure based on codes and standards will be built to survive for decades to come, it is critically important that existing climatic design information be as accurate and up-to-date as possible, that the changing climate be monitored to detect and highlight vulnerabilities of existing infrastructure, that forensic studies of climate-related failures be undertaken and that codes and standards processes incorporate future climates and extremes as much as possible. Uncertainties in the current climate change models and their scenarios currently challenge our ability to project future extremes regionally and locally. Improvements to the spatial and temporal resolution of these climate change scenarios, along with improved methodologies to treat model biases and localize results, will allow future codes and standards to better reflect the extremes and weathering conditions expected over the lifespan of structures. In the meantime, other information and code processes can be used to incorporate changing climate conditions into upcoming infrastructure codes and standards, to “bridge” the model uncertainty gap and to complement the state of existing projections. This presentation will outline some of the varied information and processes that will be used to incorporate climate change adaptation into the next development cycle of the National Building Code of Canada and numerous other national CSA infrastructure standards. (author)

  7. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.; Halverson, Mark A.

    2013-09-01

    The U.S. Department of Energy’s (DOE) Building America program implemented a new Codes and Standards Innovation (CSI) Team in 2013. The Team’s mission is to assist Building America (BA) research teams and partners in identifying and resolving conflicts between Building America innovations and the various codes and standards that govern the construction of residences. A CSI Roadmap was completed in September, 2013. This guidance document was prepared using the information in the CSI Roadmap to provide BA research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America (BA) innovations arising in and/or stemming from codes, standards, and rating methods. For more information on the BA CSI team, please email: CSITeam@pnnl.gov

  8. Low-energy office buildings using existing technology. Simulations with low internal heat gains

    Energy Technology Data Exchange (ETDEWEB)

    Flodberg, Kajsa; Blomsterberg, Aake; Dubois, Marie-Claude [Lund Univ. (Sweden). Div. of Energy and Building Design

    2012-11-01

    Although low-energy and nearly zero-energy residential houses have been built in Sweden in the past decade, there are very few examples of low-energy office buildings. This paper investigates the design features affecting energy use in office buildings and suggests the optimal low-energy design from a Swedish perspective. Dynamic simulations have been carried out with IDA ICE 4 on a typical narrow office building with perimeter cell rooms. The results from the parametric study reveal that the most important design features for energy saving are demand-controlled ventilation as well as limited glazing on the facade. Further energy-saving features are efficient lighting and office equipment which strongly reduce user-related electricity and cooling energy. Together, the simulation results suggest that about 48% energy can be saved compared to a new office building built according to the Swedish building code. Thus, it is possible, using a combination of simple and well-known building technologies and configurations, to have very low energy use in new office buildings. If renewable energy sources, such as solar energy and wind power, are added, there is a potential for the annual energy production to exceed the annual energy consumption and a net zero-energy building can be reached. One aspect of the results concerns user-related electricity, which becomes a major energy post in very low-energy offices and which is rarely regulated in building codes today. This results not only in high electricity use, but also in large internal heat gains and unnecessary high cooling loads given the high latitude and cold climate. (orig.)

  9. Evaluating the benefits of commercial building energy codes and improving federal incentives for code adoption.

    Science.gov (United States)

    Gilbraith, Nathaniel; Azevedo, Inês L; Jaramillo, Paulina

    2014-12-16

    The federal government has the goal of decreasing commercial building energy consumption and pollutant emissions by incentivizing the adoption of commercial building energy codes. Quantitative estimates of code benefits at the state level that can inform the size and allocation of these incentives are not available. We estimate the state-level climate, environmental, and health benefits (i.e., social benefits) and reductions in energy bills (private benefits) of a more stringent code (ASHRAE 90.1-2010) relative to a baseline code (ASHRAE 90.1-2007). We find that reductions in site energy use intensity range from 93 MJ/m(2) of new construction per year (California) to 270 MJ/m(2) of new construction per year (North Dakota). Total annual benefits from more stringent codes total $506 million for all states, where $372 million are from reductions in energy bills, and $134 million are from social benefits. These total benefits range from $0.6 million in Wyoming to $49 million in Texas. Private benefits range from $0.38 per square meter in Washington State to $1.06 per square meter in New Hampshire. Social benefits range from $0.2 per square meter annually in California to $2.5 per square meter in Ohio. Reductions in human/environmental damages and future climate damages account for nearly equal shares of social benefits.

  10. Compatibility of global environmental assessment methods of buildings with an Egyptian energy code

    Directory of Open Access Journals (Sweden)

    Amal Kamal Mohamed Shamseldin

    2017-04-01

    Full Text Available Several environmental assessment methods of buildings had emerged over the world to set environmental classifications for buildings, such as the American method “Leadership in Energy and Environmental Design” (LEED the most widespread one. Several countries decided to put their own assessment methods to catch up with the previous orientation, such as Egypt. The main goal of putting the Egyptian method was to impose the voluntary local energy efficiency codes. Through a local survey, it was clearly noted that many of the construction makers in Egypt do not even know the local method, and whom are interested in the environmental assessment of buildings seek to apply LEED rather than anything else. Therefore, several questions appear about the American method compatibility with the Egyptian energy codes – that contain the most exact characteristics and requirements and give the outmost credible energy efficiency results for buildings in Egypt-, and the possibility of finding another global method that gives closer results to those of the Egyptian codes, especially with the great variety of energy efficiency measurement approaches used among the different assessment methods. So, the researcher is trying to find the compatibility of using non-local assessment methods with the local energy efficiency codes. Thus, if the results are not compatible, the Egyptian government should take several steps to increase the local building sector awareness of the Egyptian method to benefit these codes, and it should begin to enforce it within the building permits after a proper guidance and feedback.

  11. Code of Practice on the International Transboundary Movement of Radioactive Waste; Code De Bonne Pratique Sur Le Mouvement Transfrontiere International De Dechets Radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-03

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States [French] Le 21 septembre 1990, la Conference generale, par la resolution GC(XXXIV)/RES/530, a adopte le Code de bonne pratique sur le mouvement transfrontiere international de dechets radioactifs et a prie le Directeur general-notamment-de prendre toutes les mesures necessaires pour assurer une large diffusion du Code de bonne pratique aux niveaux tant national qu'international. Le Code de bonne pratique a ete elabore par un groupe d'experts cree en application de la resolution GC(XXXII)/RES/490 adoptee par la Conference generale en 1988. Le texte du Code de bonne pratique est reproduit ci-apres pour l'information de tous les Etats Membres.

  12. Development and Application of a Code for Internal Exposure (CINEX) based on the CINDY code

    International Nuclear Information System (INIS)

    Kravchik, T.; Duchan, N.; Sarah, R.; Gabay, Y.; Kol, R.

    2004-01-01

    Internal exposure to radioactive materials at the NRCN is evaluated using the CINDY (Code for Internal Dosimetry) Package. The code was developed by the Pacific Northwest Laboratory to assist the interpretation of bioassay data, provide bioassay projections and evaluate committed and calendar-year doses from intake or bioassay measurement data. It provides capabilities to calculate organ dose and effective dose equivalents using the International Commission on Radiological Protection (ICRP) 30 approach. The CINDY code operates under DOS operating system and consequently its operation needs a relatively long procedure which also includes a lot of manual typing that can lead to personal human mistakes. A new code has been developed at the NRCN, the CINEX (Code for Internal Exposure), which is an Excel application and leads to a significant reduction in calculation time (in the order of 5-10 times) and in the risk of personal human mistakes. The code uses a database containing tables which were constructed by the CINDY and contain the bioassay values predicted by the ICRP30 model after an intake of an activity unit of each isotope. Using the database, the code than calculates the appropriate intake and consequently the committed effective dose and organ dose. Calculations with the CINEX code were compared to similar calculations with the CINDY code. The discrepancies were less than 5%, which is the rounding error of the CINDY code. Attached is a table which compares parameters calculated with the CINEX and the CINDY codes (for a class Y uranium). The CINEX is now used at the NRCN to calculate occupational intakes and doses to workers with radioactive materials

  13. Towards an International Code for administrative cooperation in tax matter and international tax governance

    Directory of Open Access Journals (Sweden)

    Eva Andrés Aucejo

    2017-12-01

    Full Text Available There is not a “Global Code” that encodes the duty of cooperation between tax authorities in the world, concerning the global tax system. This article addresses this issue by proposing a global Code of administrative cooperation in tax matters including both tax relations: between States, and between States, taxpayers and intermediary’s agents. It follows a wide concept of tax governance. The findings of this research have highlighted several practical applications for future practice. article analyses, firstly, the State of the question, starting with the legal sources (international and European sources of hard law and soft law reviewing the differences with the Code as here proposed. It also examines some important Agents who emit relevant normative in international administrative tax cooperation and the role that these agents are developing nowadays (sometimes international organizations but also States like the United States, which Congress enacted the Foreign Account Tax Compliance Act, FATCA. Overlapping and gaps between different regulations are underlined. Finally, the consequences of this “General Code” lack for the functioning of a good international governance, are described. Hence, the need to create an International Cooperation Code on tax matters and international fiscal governance is concluded. That Code could be proposed by any International Organization as the World Bank nature, for instance, or the International Monetary Fund or whichever International or European Organization. This instrument could be documented through a multilateral instrument (soft law, to be signed by the States to become an international legal source (hard law. Filling this Code as Articulated Text (form could be very useful for the International Community towards an International Tax Governance.

  14. Coding Theory and Applications : 4th International Castle Meeting

    CERN Document Server

    Malonek, Paula; Vettori, Paolo

    2015-01-01

    The topics covered in this book, written by researchers at the forefront of their field, represent some of the most relevant research areas in modern coding theory: codes and combinatorial structures, algebraic geometric codes, group codes, quantum codes, convolutional codes, network coding and cryptography. The book includes a survey paper on the interconnections of coding theory with constrained systems, written by an invited speaker, as well as 37 cutting-edge research communications presented at the 4th International Castle Meeting on Coding Theory and Applications (4ICMCTA), held at the Castle of Palmela in September 2014. The event’s scientific program consisted of four invited talks and 39 regular talks by authors from 24 different countries. This conference provided an ideal opportunity for communicating new results, exchanging ideas, strengthening international cooperation, and introducing young researchers into the coding theory community.

  15. Building code challenging the ethics behind adobe architecture in North Cyprus.

    Science.gov (United States)

    Hurol, Yonca; Yüceer, Hülya; Şahali, Öznem

    2015-04-01

    Adobe masonry is part of the vernacular architecture of Cyprus. Thus, it is possible to use this technology in a meaningful way on the island. On the other hand, although adobe architecture is more sustainable in comparison to other building technologies, the use of it is diminishing in North Cyprus. The application of Turkish building code in the north of the island has created complications in respect of the use of adobe masonry, because this building code demands that reinforced concrete vertical tie-beams are used together with adobe masonry. The use of reinforced concrete elements together with adobe masonry causes problems in relation to the climatic response of the building as well as causing other technical and aesthetic problems. This situation makes the design of adobe masonry complicated and various types of ethical problems also emerge. The objective of this article is to analyse the ethical problems which arise as a consequence of the restrictive character of the building code, by analysing two case studies and conducting an interview with an architect who was involved with the use of adobe masonry in North Cyprus. According to the results of this article there are ethical problems at various levels in the design of both case studies. These problems are connected to the responsibilities of architects in respect of the social benefit, material production, aesthetics and affordability of the architecture as well as presenting distrustful behaviour where the obligations of architects to their clients is concerned.

  16. ICAN Computer Code Adapted for Building Materials

    Science.gov (United States)

    Murthy, Pappu L. N.

    1997-01-01

    The NASA Lewis Research Center has been involved in developing composite micromechanics and macromechanics theories over the last three decades. These activities have resulted in several composite mechanics theories and structural analysis codes whose applications range from material behavior design and analysis to structural component response. One of these computer codes, the Integrated Composite Analyzer (ICAN), is designed primarily to address issues related to designing polymer matrix composites and predicting their properties - including hygral, thermal, and mechanical load effects. Recently, under a cost-sharing cooperative agreement with a Fortune 500 corporation, Master Builders Inc., ICAN was adapted to analyze building materials. The high costs and technical difficulties involved with the fabrication of continuous-fiber-reinforced composites sometimes limit their use. Particulate-reinforced composites can be thought of as a viable alternative. They are as easily processed to near-net shape as monolithic materials, yet have the improved stiffness, strength, and fracture toughness that is characteristic of continuous-fiber-reinforced composites. For example, particlereinforced metal-matrix composites show great potential for a variety of automotive applications, such as disk brake rotors, connecting rods, cylinder liners, and other hightemperature applications. Building materials, such as concrete, can be thought of as one of the oldest materials in this category of multiphase, particle-reinforced materials. The adaptation of ICAN to analyze particle-reinforced composite materials involved the development of new micromechanics-based theories. A derivative of the ICAN code, ICAN/PART, was developed and delivered to Master Builders Inc. as a part of the cooperative activity.

  17. Development of Probabilistic Internal Dosimetry Computer Code

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Siwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kwon, Tae-Eun [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Lee, Jai-Ki [Korean Association for Radiation Protection, Seoul (Korea, Republic of)

    2017-02-15

    Internal radiation dose assessment involves biokinetic models, the corresponding parameters, measured data, and many assumptions. Every component considered in the internal dose assessment has its own uncertainty, which is propagated in the intake activity and internal dose estimates. For research or scientific purposes, and for retrospective dose reconstruction for accident scenarios occurring in workplaces having a large quantity of unsealed radionuclides, such as nuclear power plants, nuclear fuel cycle facilities, and facilities in which nuclear medicine is practiced, a quantitative uncertainty assessment of the internal dose is often required. However, no calculation tools or computer codes that incorporate all the relevant processes and their corresponding uncertainties, i.e., from the measured data to the committed dose, are available. Thus, the objective of the present study is to develop an integrated probabilistic internal-dose-assessment computer code. First, the uncertainty components in internal dosimetry are identified, and quantitative uncertainty data are collected. Then, an uncertainty database is established for each component. In order to propagate these uncertainties in an internal dose assessment, a probabilistic internal-dose-assessment system that employs the Bayesian and Monte Carlo methods. Based on the developed system, we developed a probabilistic internal-dose-assessment code by using MATLAB so as to estimate the dose distributions from the measured data with uncertainty. Using the developed code, we calculated the internal dose distribution and statistical values (e.g. the 2.5{sup th}, 5{sup th}, median, 95{sup th}, and 97.5{sup th} percentiles) for three sample scenarios. On the basis of the distributions, we performed a sensitivity analysis to determine the influence of each component on the resulting dose in order to identify the major component of the uncertainty in a bioassay. The results of this study can be applied to various

  18. Development of Probabilistic Internal Dosimetry Computer Code

    International Nuclear Information System (INIS)

    Noh, Siwan; Kwon, Tae-Eun; Lee, Jai-Ki

    2017-01-01

    Internal radiation dose assessment involves biokinetic models, the corresponding parameters, measured data, and many assumptions. Every component considered in the internal dose assessment has its own uncertainty, which is propagated in the intake activity and internal dose estimates. For research or scientific purposes, and for retrospective dose reconstruction for accident scenarios occurring in workplaces having a large quantity of unsealed radionuclides, such as nuclear power plants, nuclear fuel cycle facilities, and facilities in which nuclear medicine is practiced, a quantitative uncertainty assessment of the internal dose is often required. However, no calculation tools or computer codes that incorporate all the relevant processes and their corresponding uncertainties, i.e., from the measured data to the committed dose, are available. Thus, the objective of the present study is to develop an integrated probabilistic internal-dose-assessment computer code. First, the uncertainty components in internal dosimetry are identified, and quantitative uncertainty data are collected. Then, an uncertainty database is established for each component. In order to propagate these uncertainties in an internal dose assessment, a probabilistic internal-dose-assessment system that employs the Bayesian and Monte Carlo methods. Based on the developed system, we developed a probabilistic internal-dose-assessment code by using MATLAB so as to estimate the dose distributions from the measured data with uncertainty. Using the developed code, we calculated the internal dose distribution and statistical values (e.g. the 2.5 th , 5 th , median, 95 th , and 97.5 th percentiles) for three sample scenarios. On the basis of the distributions, we performed a sensitivity analysis to determine the influence of each component on the resulting dose in order to identify the major component of the uncertainty in a bioassay. The results of this study can be applied to various situations. In cases

  19. Using Third-Party Inspectors in Building Energy Codes Enforcement in India

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha; Evans, Meredydd; Kumar, Pradeep; Van Wie, Laura; Bhatt, Vatsal

    2013-01-31

    India is experiencing fast income growth and urbanization, and this leads to unprecedented increases in demand for building energy services and resulting energy consumption. In response to rapid growth in building energy use, the Government of India issued the Energy Conservation Building Code (ECBC) in 2007, which is consistent with and based on the 2001 Energy Conservation Act. ECBC implementation has been voluntary since its enactment and a few states have started to make progress towards mandatory implementation. Rajasthan is the first state in India to adopt ECBC as a mandatory code. The State adopted ECBC with minor additions on March 28, 2011 through a stakeholder process; it became mandatory in Rajasthan on September 28, 2011. Tamil Nadu, Gujarat, and Andhra Pradesh have started to draft an implementation roadmap and build capacity for its implementation. The Bureau of Energy Efficiency (BEE) plans to encourage more states to adopt ECBC in the near future, including Haryana, Uttar Pradesh, Karnataka, Maharashtra, West Bengal, and Delhi. Since its inception, India has applied the code on a voluntary basis, but the Government of India is developing a strategy to mandate compliance. Implementing ECBC requires coordination between the Ministry of Power and the Ministry of Urban Development at the national level as well as interdepartmental coordination at the state level. One challenge is that the Urban Local Bodies (ULBs), the enforcement entities of building by-laws, lack capacity to implement ECBC effectively. For example, ULBs in some states might find the building permitting procedures to be too complex; in other cases, lack of awareness and technical knowledge on ECBC slows down the amendment of local building by-laws as well as ECBC implementation. The intent of this white paper is to share with Indian decision-makers code enforcement approaches: through code officials, third-party inspectors, or a hybrid approach. Given the limited capacity and human

  20. Innovation and Standardization in School Building: A Proposal for the National Code in Italy.

    Science.gov (United States)

    Ridolfi, Giuseppe

    This document discusses the University of Florence's experience and concepts as it developed the research to define a proposal for designing a new national school building code. Section 1 examines the current school building code and the Italian Reform Process in Education between 1960 and 2000. Section 2 details and explains the new school…

  1. The impact of international codes of conduct on employment ...

    African Journals Online (AJOL)

    The study examined how international codes of conduct address employment conditions and gender issues in the Chinese flower industry. A sample of 20 companies was purposively selected and 200 workers from these companies were interviewed. The adoption of international codes did not improve workers conditions ...

  2. Zero Energy Building

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Heiselberg, Per; Bourrelle, J.S.

    2011-01-01

    The concept of Zero Energy Building (ZEB) has gained wide international attention during last few years and is now seen as the future target for the design of buildings. However, before being fully implemented in the national building codes and international standards, the ZEB concept requires......, (4) the type of energy balance, (5) the accepted renewable energy supply options, (6) the connection to the energy infrastructure and (7) the requirements for the energy efficiency, the indoor climate and in case of gird connected ZEB for the building–grid interaction. This paper focuses...

  3. Code for Internal Dosimetry (CINDY)

    International Nuclear Information System (INIS)

    Strenge, D.L.; Peloquin, R.A.; Sula, M.J.; Johnson, J.R.

    1990-10-01

    The CINDY (Code for Internal Dosimetry) Software Package has been developed by Pacific Northwest Laboratory to address the Department of Energy (DOE) Order 5480.11 by providing the capabilities to calculate organ dose equivalents and effective dose equivalents using the approach of International Commission on Radiological Protection (ICRP) 30. The code assist in the interpretation of bioassay data, evaluates committed and calendar-year doses from intake or bioassay measurement data, provides output consistent with revised DOE orders, is easy to use, and is generally applicable to DOE sites. Flexible biokinetics models are used to determine organ doses for annual, 50-year, calendar-year, or any other time-point dose necessary for chronic or acute intakes. CINDY is an interactive program that prompts the user to describe the cases to be analyzed and calculates the necessary results for the type of analysis being performed. Four types of analyses may be specified. 92 figs., 10 tabs

  4. 76 FR 13101 - Building Energy Codes Program: Presenting and Receiving Comments to DOE Proposed Changes to the...

    Science.gov (United States)

    2011-03-10

    ... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket No. EERE-2011-BT-BC-0009] Building Energy Codes.... The IgCC is intended to provide a green model building code provisions for new and existing commercial... Code (IgCC) AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION...

  5. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Wang, Weimin

    2016-02-15

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energy code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.

  6. Residential building codes, affordability, and health protection: a risk-tradeoff approach.

    Science.gov (United States)

    Hammitt, J K; Belsky, E S; Levy, J I; Graham, J D

    1999-12-01

    Residential building codes intended to promote health and safety may produce unintended countervailing risks by adding to the cost of construction. Higher construction costs increase the price of new homes and may increase health and safety risks through "income" and "stock" effects. The income effect arises because households that purchase a new home have less income remaining for spending on other goods that contribute to health and safety. The stock effect arises because suppression of new-home construction leads to slower replacement of less safe housing units. These countervailing risks are not presently considered in code debates. We demonstrate the feasibility of estimating the approximate magnitude of countervailing risks by combining the income effect with three relatively well understood and significant home-health risks. We estimate that a code change that increases the nationwide cost of constructing and maintaining homes by $150 (0.1% of the average cost to build a single-family home) would induce offsetting risks yielding between 2 and 60 premature fatalities or, including morbidity effects, between 20 and 800 lost quality-adjusted life years (both discounted at 3%) each year the code provision remains in effect. To provide a net health benefit, the code change would need to reduce risk by at least this amount. Future research should refine these estimates, incorporate quantitative uncertainty analysis, and apply a full risk-tradeoff approach to real-world case studies of proposed code changes.

  7. Performance Assessment and analysis of national building codes with fire safety in all wards of a hospital

    Directory of Open Access Journals (Sweden)

    M. Mahdinia

    2009-04-01

    Full Text Available Background and aimsAIDS as a re-emergent disease and Viral hepatitis (B and C as one of thBackground and objective: Fire safety is an important problem in hospitals. Movement less, lack of awareness and special situation of residents are the reasons of this subject. In more countries such as Iran, fire protection regulations have compiled within the framework of national building codes. Current building codes don't create sufficient safety for patient in the hospitals in different situations and more of the advanced countries in the world effort to establish building code, base  on performance. This study to be accomplished with this goal that determination of fire risk level in the wards of a hospital and survey the efficiency of the national building codes. Methodsfire risk assesses is done, using "engineering fire risk assessment method" with the checklist for Data gathering. In this manner, risk calculate in all compartments and in the next  stage for survey the effect of building codes, with this supposition that all compartment is  conforming to building code requirement, risk level calculate in two situation.Resultsthe results of present study reveals that, risk level in all wards is more than one and even though risk less than one is acceptable, consequently minimum of safely situations didn't  produce in most wards. The results show the national building code in the different conditions  don't have appropriate efficient for creation of suitable safety. Conclusionin order to access to a fire safety design with sufficient efficiency, suitable selection is use of risk assessment based on, design methods.

  8. International assessment of PCA codes

    International Nuclear Information System (INIS)

    Neymotin, L.; Lui, C.; Glynn, J.; Archarya, S.

    1993-11-01

    Over the past three years (1991-1993), an extensive international exercise for intercomparison of a group of six Probabilistic Consequence Assessment (PCA) codes was undertaken. The exercise was jointly sponsored by the Commission of European Communities (CEC) and OECD Nuclear Energy Agency. This exercise was a logical continuation of a similar effort undertaken by OECD/NEA/CSNI in 1979-1981. The PCA codes are currently used by different countries for predicting radiological health and economic consequences of severe accidents at nuclear power plants (and certain types of non-reactor nuclear facilities) resulting in releases of radioactive materials into the atmosphere. The codes participating in the exercise were: ARANO (Finland), CONDOR (UK), COSYMA (CEC), LENA (Sweden), MACCS (USA), and OSCAAR (Japan). In parallel with this inter-code comparison effort, two separate groups performed a similar set of calculations using two of the participating codes, MACCS and COSYMA. Results of the intercode and inter-MACCS comparisons are presented in this paper. The MACCS group included four participants: GREECE: Institute of Nuclear Technology and Radiation Protection, NCSR Demokritos; ITALY: ENEL, ENEA/DISP, and ENEA/NUC-RIN; SPAIN: Universidad Politecnica de Madrid (UPM) and Consejo de Seguridad Nuclear; USA: Brookhaven National Laboratory, US NRC and DOE

  9. Empirical evidence for site coefficients in building code provisions

    Science.gov (United States)

    Borcherdt, R.D.

    2002-01-01

    Site-response coefficients, Fa and Fv, used in U.S. building code provisions are based on empirical data for motions up to 0.1 g. For larger motions they are based on theoretical and laboratory results. The Northridge earthquake of 17 January 1994 provided a significant new set of empirical data up to 0.5 g. These data together with recent site characterizations based on shear-wave velocity measurements provide empirical estimates of the site coefficients at base accelerations up to 0.5 g for Site Classes C and D. These empirical estimates of Fa and Fnu; as well as their decrease with increasing base acceleration level are consistent at the 95 percent confidence level with those in present building code provisions, with the exception of estimates for Fa at levels of 0.1 and 0.2 g, which are less than the lower confidence bound by amounts up to 13 percent. The site-coefficient estimates are consistent at the 95 percent confidence level with those of several other investigators for base accelerations greater than 0.3 g. These consistencies and present code procedures indicate that changes in the site coefficients are not warranted. Empirical results for base accelerations greater than 0.2 g confirm the need for both a short- and a mid- or long-period site coefficient to characterize site response for purposes of estimating site-specific design spectra.

  10. The internal dosimetry code PLEIADES.

    Science.gov (United States)

    Fell, T P; Phipps, A W; Smith, T J

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts-the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included.

  11. The internal dosimetry code PLEIADES

    International Nuclear Information System (INIS)

    Fell, T. P.; Phipps, A. W.; Smith, T. J.

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts - the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included. (authors)

  12. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Science.gov (United States)

    2010-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  13. Nuclear component design ontology building based on ASME codes

    International Nuclear Information System (INIS)

    Bao Shiyi; Zhou Yu; He Shuyan

    2005-01-01

    The adoption of ontology analysis in the study of concept knowledge acquisition and representation for the nuclear component design process based on computer-supported cooperative work (CSCW) makes it possible to share and reuse numerous concept knowledge of multi-disciplinary domains. A practical ontology building method is accordingly proposed based on Protege knowledge model in combination with both top-down and bottom-up approaches together with Formal Concept Analysis (FCA). FCA exhibits its advantages in the way it helps establish and improve taxonomic hierarchy of concepts and resolve concept conflict occurred in modeling multi-disciplinary domains. With Protege-3.0 as the ontology building tool, a nuclear component design ontology based ASME codes is developed by utilizing the ontology building method. The ontology serves as the basis to realize concept knowledge sharing and reusing of nuclear component design. (authors)

  14. International conventions for measuring radioactivity of building materials

    International Nuclear Information System (INIS)

    Tan Chenglong

    2004-01-01

    In buildings, whether civil or industrial, natural radioactivity always occurs at different degrees in the materials (main building materials, decorative materials). Concerns on radioactivity from building materials is unavoidable for human living and developing. As a member of WTO, China's measuring method of radioactivity for building materials, including radionuclides limitation for building materials, hazard evaluation system etc, should keep accordance with the international rules and conventions. (author)

  15. Environmental performance of green building code and certification systems.

    Science.gov (United States)

    Suh, Sangwon; Tomar, Shivira; Leighton, Matthew; Kneifel, Joshua

    2014-01-01

    We examined the potential life-cycle environmental impact reduction of three green building code and certification (GBCC) systems: LEED, ASHRAE 189.1, and IgCC. A recently completed whole-building life cycle assessment (LCA) database of NIST was applied to a prototype building model specification by NREL. TRACI 2.0 of EPA was used for life cycle impact assessment (LCIA). The results showed that the baseline building model generates about 18 thousand metric tons CO2-equiv. of greenhouse gases (GHGs) and consumes 6 terajoule (TJ) of primary energy and 328 million liter of water over its life-cycle. Overall, GBCC-compliant building models generated 0% to 25% less environmental impacts than the baseline case (average 14% reduction). The largest reductions were associated with acidification (25%), human health-respiratory (24%), and global warming (GW) (22%), while no reductions were observed for ozone layer depletion (OD) and land use (LU). The performances of the three GBCC-compliant building models measured in life-cycle impact reduction were comparable. A sensitivity analysis showed that the comparative results were reasonably robust, although some results were relatively sensitive to the behavioral parameters, including employee transportation and purchased electricity during the occupancy phase (average sensitivity coefficients 0.26-0.29).

  16. Can envelope codes reduce electricity and CO2 emissions in different types of buildings in the hot climate of Bahrain?

    International Nuclear Information System (INIS)

    Radhi, H.

    2009-01-01

    The depletion of non-renewable resources and the environmental impact of energy consumption, particularly energy use in buildings, have awakened considerable interest in energy efficiency. Building energy codes have recently become effective techniques to achieve efficiency targets. The Electricity and Water Authority in Bahrain has set a target of 40% reduction of building electricity consumption and CO 2 emissions to be achieved by using envelope thermal insulation codes. This paper investigates the ability of the current codes to achieve such a benchmark and evaluates their impact on building energy consumption. The results of a simulation study are employed to investigate the impact of the Bahraini codes on the energy and environmental performance of buildings. The study focuses on air-conditioned commercial buildings and concludes that envelope codes, at best, are likely to reduce the energy use of the commercial sector by 25% if the building envelope is well-insulated and efficient glazing is used. Bahraini net CO 2 emissions could drop to around 7.1%. The simulation results show that the current energy codes alone are not sufficient to achieve a 40% reduction benchmark, and therefore, more effort should be spent on moving towards a more comprehensive approach

  17. Preserving Envelope Efficiency in Performance Based Code Compliance

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A. [Thornton Energy Consulting (United States); Sullivan, Greg P. [Efficiency Solutions (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Baechler, Michael C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-20

    The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringent than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.

  18. INTRANS. A computer code for the non-linear structural response analysis of reactor internals under transient loads

    International Nuclear Information System (INIS)

    Ramani, D.T.

    1977-01-01

    The 'INTRANS' system is a general purpose computer code, designed to perform linear and non-linear structural stress and deflection analysis of impacting or non-impacting nuclear reactor internals components coupled with reactor vessel, shield building and external as well as internal gapped spring support system. This paper describes in general a unique computational procedure for evaluating the dynamic response of reactor internals, descretised as beam and lumped mass structural system and subjected to external transient loads such as seismic and LOCA time-history forces. The computational procedure is outlined in the INTRANS code, which computes component flexibilities of a discrete lumped mass planar model of reactor internals by idealising an assemblage of finite elements consisting of linear elastic beams with bending, torsional and shear stiffnesses interacted with external or internal linear as well as non-linear multi-gapped spring support system. The method of analysis is based on the displacement method and the code uses the fourth-order Runge-Kutta numerical integration technique as a basis for solution of dynamic equilibrium equations of motion for the system. During the computing process, the dynamic response of each lumped mass is calculated at specific instant of time using well-known step-by-step procedure. At any instant of time then, the transient dynamic motions of the system are held stationary and based on the predicted motions and internal forces of the previous instant. From which complete response at any time-step of interest may then be computed. Using this iterative process, the relationship between motions and internal forces is satisfied step by step throughout the time interval

  19. Effect of URM infills on seismic vulnerability of Indian code designed RC frame buildings

    Science.gov (United States)

    Haldar, Putul; Singh, Yogendra; Paul, D. K.

    2012-03-01

    Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction, the general design practice is to treat infills as nonstructural elements and their stiffness, strength and interaction with the frame is often ignored, primarily because of difficulties in simulation and lack of modeling guidelines in design codes. The Indian Standard, like many other national codes, does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames. This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills. Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered. HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames. The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.

  20. Comparison of SISEC code simulations with earthquake data of ordinary and base-isolated buildings

    International Nuclear Information System (INIS)

    Wang, C.Y.; Gvildys, J.

    1991-01-01

    At Argonne National Laboratory (ANL), a 3-D computer program SISEC (Seismic Isolation System Evaluation Code) is being developed for simulating the system response of isolated and ordinary structures (Wang et al. 1991). This paper describes comparison of SISEC code simulations with building response data of actual earthquakes. To ensure the accuracy of analytical simulations, recorded data of full-size reinforced concrete structures located in Sendai, Japan are used in this benchmark comparison. The test structures consist of two three-story buildings, one base-isolated and the other one ordinary founded. They were constructed side by side to investigate the effect of base isolation on the acceleration response. Among 20 earthquakes observed since April 1989, complete records of three representative earthquakes, no.2, no.6, and no.17, are used for the code validation presented in this paper. Correlations of observed and calculated accelerations at all instrument locations are made. Also, relative response characteristics of ordinary and isolated building structures are investigated. (J.P.N.)

  1. Guidelines and procedures for the International Code Assessment and Applications Program

    International Nuclear Information System (INIS)

    1987-04-01

    This document presents the guidelines and procedures by which the International Code Assessment and Applications Program (ICAP) will be conducted. The document summarizes the management structure of the program and the relationships between and responsibilities of the United States Nuclear Regulatory Commission (USNRC) and the international participants. The procedures for code maintenance and necessary documentation are described. Guidelines for the performance and documentation of code assessment studies are presented. An overview of an effort to quantify code uncertainty, which the ICAP supports, is included

  2. International Code Assessment and Applications Program: Annual report

    International Nuclear Information System (INIS)

    Ting, P.; Hanson, R.; Jenks, R.

    1987-03-01

    This is the first annual report of the International Code Assessment and Applications Program (ICAP). The ICAP was organized by the Office of Nuclear Regulatory Research, United States Nuclear Regulatory Commission (USNRC) in 1985. The ICAP is an international cooperative reactor safety research program planned to continue over a period of approximately five years. To date, eleven European and Asian countries/organizations have joined the program through bilateral agreements with the USNRC. Seven proposed agreements are currently under negotiation. The primary mission of the ICAP is to provide independent assessment of the three major advanced computer codes (RELAP5, TRAC-PWR, and TRAC-BWR) developed by the USNRC. However, program activities can be expected to enhance the assessment process throughout member countries. The codes were developed to calculate the reactor plant response to transients and loss-of-coolant accidents. Accurate prediction of normal and abnormal plant response using the codes enhances procedures and regulations used for the safe operation of the plant and also provides technical basis for assessing the safety margin of future reactor plant designs. The ICAP is providing required assessment data that will contribute to quantification of the code uncertainty for each code. The first annual report is devoted to coverage of program activities and accomplishments during the period between April 1985 and March 1987

  3. Energy conservation: policy issues and end-use scenarios of savings potential. Part V. Energy efficient buildings: the causes of litigation against energy conservation building codes

    Energy Technology Data Exchange (ETDEWEB)

    Benenson, P.; Codina, R.; Cornwall, B.

    1978-09-01

    The guidelines laid out for the five subjects investigated in this series are to take a holistic view of energy conservation policies by describing the overall system in which they are implemented; provide analytical tools and sufficiently disagregated data bases that can be adapted to answer a variety of questions by the users; identify and discuss some of the important issues behind successful energy conservation policy; and develop an energy conservation policy in depth. Three specific cases reviewed are: the California nonresidential code (1976); the California residential code (1978); and the Farmers Home Administration code (1978). Although these three suits were brought by the building industry, this report also discusses considerations relevant to architects, bankers, and building inspectors. These cases are discussed from three perspectives: (1) objections to the codes explicitly stated in court, (2) industry conditions and practices behind objections stated in court, and (3) general beliefs not stated in court. This discussion focuses on suits intended to limit those building codes which the building industry sees as too strong. However, some energy conservation industries may sue to strengthen codes which they consider too weak. An example of such a case is Polarized Corporation's current suit against the Lighting section of ASHRAE 90-75 (Los Angeles Federal District Court, see Murnane, 1978). (MCW)

  4. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, M. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

  5. Experience with COSYMA in an international intercomparison of probabilistic accident consequence assessment codes

    International Nuclear Information System (INIS)

    Hasemann, I.; Jones, J.A.; Steen, J. van der; Wonderen, E. van

    1996-01-01

    The Commission of the European Communities and the Nuclear Energy Agency of the OECD have organized an international exercise to compare the predictions of accident consequence assessment codes, and to identify those features of the models which lead to differences in the predicted results. Alongside this, a further exercise was undertaken in which the COSYMA code was used independently by several different organizations. Some of the findings of the COSYMA users' exercise are described that have general applications to accident consequence assessments. A number of areas are identified in which further work on accident consequence models may be justified. These areas, which are also of interest for codes other than COSYMA, are (a) the calculation and averaging of doses and risks to people sheltered in different types of buildings, particularly with respect to the evaluation of early health effects; (b) the modeling of long-duration releases and their description as a series of shorter releases; (c) meteorological sampling for results at a certain location, specifically for use with trajectory models of atmospheric dispersion; and (d) aspects of calculating probabilities of consequences at a point

  6. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    Science.gov (United States)

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  7. Does a code make a difference – assessing the English code of practice on international recruitment

    Directory of Open Access Journals (Sweden)

    Mensah Kwadwo

    2009-04-01

    Full Text Available Abstract Background This paper draws from research completed in 2007 to assess the effect of the Department of Health, England, Code of Practice for the international recruitment of health professionals. The Department of Health in England introduced a Code of Practice for international recruitment for National Health Service employers in 2001. The Code required National Health Service employers not to actively recruit from low-income countries, unless there was government-to-government agreement. The Code was updated in 2004. Methods The paper examines trends in inflow of health professionals to the United Kingdom from other countries, using professional registration data and data on applications for work permits. The paper also provides more detailed information from two country case studies in Ghana and Kenya. Results Available data show a considerable reduction in inflow of health professionals, from the peak years up to 2002 (for nurses and 2004 (for doctors. There are multiple causes for this decline, including declining demand in the United Kingdom. In Ghana and Kenya it was found that active recruitment was perceived to have reduced significantly from the United Kingdom, but it is not clear the extent to which the Code was influential in this, or whether other factors such as a lack of vacancies in the United Kingdom explains it. Conclusion Active international recruitment of health professionals was an explicit policy intervention by the Department of Health in England, as one key element in achieving rapid staffing growth, particularly in the period 2000 to 2005, but the level of international recruitment has dropped significantly since early 2006. Regulatory and education changes in the United Kingdom in recent years have also made international entry more difficult. The potential to assess the effect of the Code in England is constrained by the limitations in available databases. This is a crucial lesson for those considering a

  8. Capturing Energy-Saving Opportunities: Improving Building Efficiency in Rajasthan through Energy Code Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Qing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Yu, Sha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Evans, Meredydd [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mathur, Jyotirmay [Malaviya National Institute of Technology, Jaipur (India); Vu, Linh D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    India adopted the Energy Conservation Building Code (ECBC) in 2007. Rajasthan is the first state to make ECBC mandatory at the state level. In collaboration with Malaviya National Institute of Technology (MNIT) Jaipur, Pacific Northwest National Laboratory (PNNL) has been working with Rajasthan to facilitate the implementation of ECBC. This report summarizes milestones made in Rajasthan and PNNL's contribution in institutional set-ups, capacity building, compliance enforcement and pilot building construction.

  9. Fusion safety codes International modeling with MELCOR and ATHENA- INTRA

    CERN Document Server

    Marshall, T; Topilski, L; Merrill, B

    2002-01-01

    For a number of years, the world fusion safety community has been involved in benchmarking their safety analyses codes against experiment data to support regulatory approval of a next step fusion device. This paper discusses the benchmarking of two prominent fusion safety thermal-hydraulic computer codes. The MELCOR code was developed in the US for fission severe accident safety analyses and has been modified for fusion safety analyses. The ATHENA code is a multifluid version of the US-developed RELAP5 code that is also widely used for fusion safety analyses. The ENEA Fusion Division uses ATHENA in conjunction with the INTRA code for its safety analyses. The INTRA code was developed in Germany and predicts containment building pressures, temperatures and fluid flow. ENEA employs the French-developed ISAS system to couple ATHENA and INTRA. This paper provides a brief introduction of the MELCOR and ATHENA-INTRA codes and presents their modeling results for the following breaches of a water cooling line into the...

  10. Code of Practice on the International Transboundary Movement of Radioactive Waste

    International Nuclear Information System (INIS)

    1990-11-01

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States

  11. Code of Practice on the International Transboundary Movement of Radioactive Waste

    International Nuclear Information System (INIS)

    1990-01-01

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States [fr

  12. Code of Practice on the International Transboundary Movement of Radioactive Waste

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-14

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States.

  13. Code of Practice on the International Transboundary Movement of Radioactive Waste

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-15

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States.

  14. Code of Practice on the International Transboundary Movement of Radioactive Waste

    International Nuclear Information System (INIS)

    1990-01-01

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States

  15. Analysis of Potential Benefits and Costs of Updating the Commercial Building Energy Code in Iowa

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Richman, Eric E.; Winiarski, David W.

    2002-09-07

    The state of Iowa is considering adpoting ASHRAE 90.1-1999 as its commercial building energy code. In an effort to evaluate whether or not this is an appropraite code for the state, the potential benefits and costs of adopting this standard are considered. Both qualitative and quantitative benefits are assessed. The energy simulation and economic results suggest that adopting ASHRAE 90.1-1999 would provide postitive net benefits to the state relative to the building and design requirements currently in place.

  16. Building Bridges: Psi Chi and International Psychology

    Directory of Open Access Journals (Sweden)

    Mercedes A McCormick

    2014-12-01

    Full Text Available “How can Psi Chi best partner with international psychologists to expand the honor society world-wide?” This has been an important question since 2009, when the 1,100 chapters of Psi Chi in the United States voted to become “The International Honor Society in Psychology”. This report updates and expands on a unique symposium offered at the 120th meeting of the American Psychological Association in Orlando, Florida, in August of 2012 - the first symposium on the Presidential theme of “Building Bridges” between Psi Chi and international psychology [8]. Here, seven leaders in international psychology in North and South America join to address different aspects of this timely question--with many suggestions on how to “build bridges” to expand Psi Chi globally. It was in part due to this historic symposium that in 2013 Guatemala became the first nation in Latin America, and Russia the first nation in mainland Europe to launch a chapter of Psi Chi.

  17. 4th international conference in sustainability in energy and buildings

    CERN Document Server

    Höjer, Mattias; Howlett, Robert; Jain, Lakhmi

    2013-01-01

    This volume contains the proceedings of the Fourth International Conference on Sustainability in Energy and Buildings, SEB12, held in Stockholm, Sweden, and is organised by KTH Royal Institute of Technology, Stockholm, Sweden in partnership with KES International. The International Conference on Sustainability in Energy and Buildings focuses on a broad range of topics relating to sustainability in buildings but also encompassing energy sustainability more widely. Following the success of earlier events in the series, the 2012 conference includes the themes Sustainability, Energy, and Buildings and Information and Communication Technology, ICT. The SEB’12 proceedings includes invited participation and paper submissions across a broad range of renewable energy and sustainability-related topics relevant to the main theme of Sustainability in Energy and Buildings. Applicable areas include technology for renewable energy and sustainability in the built environment, optimisation and modeling techniques, informati...

  18. The extensive international use of commercial computational fluid dynamics (CFD) codes

    International Nuclear Information System (INIS)

    Hartmut Wider

    2005-01-01

    What are the main reasons for the extensive international success of commercial CFD codes? This is due to their ability to calculate the fine structures of the investigated processes due to their versatility, their numerical stability and that they can guarantee the proper solution in most cases. This was made possible by the constantly increasing computer power at an ever more affordable prize. Furthermore it is much more efficient to have researchers use a CFD code rather than to develop a similar code system due to the time consuming nature of this activity and the high probability of hidden coding errors. The centralized development and upgrading makes these reliable CFD codes possible and affordable. However, the CFD companies' developments are naturally concentrated on the most profitable areas, and thus, if one works in a 'non-priority' field one cannot use them. Moreover, the prize of renting CFD codes, applications to complex systems such as whole nuclear reactors and the need to teach students gives the development of self-made codes still plenty of room. But CFD codes can model detailed aspects of large systems and subroutines generated by users can be added. Since there are only a few heavily used CFD codes such as FLUENT, STAR-CD, ANSYS CFX, these are used in many countries. Also international training courses are given and the news bulletins of these codes help to spread the news on further developments. A larger number of international codes would increase the competition but would at the same time make it harder to select the most appropriate CFD code for a given problem. Examples will be presented of uses of CFD codes as more detailed system codes for the decay heat removal from reactors, the application to aerosol physics and the application to heavy metal fluids using different turbulence models. (author)

  19. A novel method of generating and remembering international morse codes

    Digital Repository Service at National Institute of Oceanography (India)

    Charyulu, R.J.K.

    untethered communications have been advanced, despite as S.O.S International Morse Code will be at rescue as an emergency tool, when all other modes fail The details of hte method and actual codes have been enumerated....

  20. Building energy performance analysis by an in-house developed dynamic simulation code: An investigation for different case studies

    International Nuclear Information System (INIS)

    Buonomano, Annamaria; Palombo, Adolfo

    2014-01-01

    Highlights: • A new dynamic simulation code for building energy performance analysis is presented. • The thermal behavior of each building element is modeled by a thermal RC network. • The physical models implemented in the code are illustrated. • The code was validated by the BESTEST standard procedure. • We investigate residential buildings, offices and stores in different climates. - Abstract: A novel dynamic simulation model for the building envelope energy performance analysis is presented in this paper. This tool helps the investigation of many new building technologies to increase the system energy efficiency and it can be carried out for scientific research purposes. In addition to the yearly heating and cooling load and energy demand, the obtained output is the dynamic temperature profile of indoor air and surfaces and the dynamic profile of the thermal fluxes through the building elements. The presented simulation model is also validated through the BESTEST standard procedure. Several new case studies are developed for assessing, through the presented code, the energy performance of three different building envelopes with several different weather conditions. In particular, dwelling and commercial buildings are analysed. Light and heavyweight envelopes as well as different glazed surfaces areas have been used for every case study. With the achieved results interesting design and operating guidelines can be obtained. Such data have been also compared vs. those calculated by TRNSYS and EnergyPlus. The detected deviation of the obtained results vs. those of such standard tools are almost always lower than 10%

  1. Is the international safety management code an organisational tool ...

    African Journals Online (AJOL)

    The birth of the International Management Code for the Safe Operation of Ships and for Pollution Prevention (hereinafter ISM Code) is said to a reaction to the sinking of the Herald of free Enterprise on 6th March 1987.The human element is said to be a generic term used to describe what makes humans behave the way ...

  2. Estimation of skyshine dose from turbine building of BWR plant using Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Yuji, Nemoto; Toshihisa, Tsukiyama; Shigeki, Nemezawa [Hitachi. Ltd., Saiwai-cho, Hitachi (Japan); Tadashi, Yamasaki; Hidetsugu, Okada [Chubu Electric Power Company, Inc., Odaka-cho, Midori-ku Nagoya (Japan)

    2007-07-01

    The Monte Carlo N-Particle transport code (MCNP) was adopted to calculate the skyshine dose from the turbine building of a BWR plant for obtaining precise estimations at the site boundary. In MCNP calculation, the equipment and piping arranged on the operating floor of the turbine building were considered and modeled in detail. The inner and outer walls of the turbine building, the shielding materials around the high-pressure turbine, and the piping connected from the moisture separator to the low-pressure turbine were all considered. A three-step study was conducted to estimate the applicability of MCNP code. The first step is confirming the propriety of calculation models. The atmospheric relief diaphragms, which are installed on top of the low-pressure turbine exhaust hood, are not considered in the calculation model. There was little difference between the skyshine dose distributions that were considered when using and not using the atmospheric relief diaphragms. The calculated dose rates agreed well with the measurements taken around the turbine. The second step is estimating the dose rates on the outer roof surface of the turbine building. This calculation was made to confirm the dose distribution of gamma-rays on the turbine roof before being scattered into the air. The calculated dose rates agreed well with the measured data. The third step is making a final confirmation by comparing the calculations and measurements of skyshine dose rates around the turbine building. The source terms of the main steam system are based on the measured activity data of N-16 and C-15. As a conclusion, we were able to calculate reasonable skyshine dose rates by using MCNP code. (authors)

  3. Implementation of international code of marketing breast-milk substitutes in China.

    Science.gov (United States)

    Liu, Aihua; Dai, Yaohua; Xie, Xiaohua; Chen, Li

    2014-11-01

    Breastmilk is the best source of nourishment for infants and young children, and breastfeeding is one of the most effective ways to ensure child health and survival. In May 1981, the World Health Assembly adopted the International Code of Marketing Breast-Milk Substitutes. Since then several subsequent resolutions have been adopted by the World Health Assembly, which both update and clarify the articles within the International Code (herein after the term "Code" refers to both the International Code and all subsequent resolutions). The Code is designed to regulate "inappropriate sales promotion" of breastmilk substitutes and instructs signatory governments to ensure the implementation of its aims through legislation. The Chinese Regulations of the Code were adopted by six government sectors in 1995. However, challenges in promotion, protection, and support of breastfeeding remain. This study aimed to monitor the implementation of the Code in China. Six cities were selected with considerable geographic coverage. In each city three hospitals and six stores were surveyed. The International Baby Food Action Network Interview Form was adapted, and direct observations were made. Research assistants administered the questionnaires to a random sample of mothers of infants under 6 months old who were in the outpatient department of the hospitals. In total, 291 mothers of infants, 35 stores, 17 hospitals, and 26 companies were surveyed. From the whole sample of 291 mothers, the proportion who reported exclusively breastfeeding their infant was 30.9%; 69.1% of mothers reported feeding their infant with commercially available formula. Regarding violations of the Code, 40.2% of the mothers reported receiving free formula samples. Of these, 76.1% received the free samples in or near hospitals. Among the stores surveyed, 45.7% were found promoting products in a way that violates the Code. Also, 69.0% of the labeling on the formula products did not comply with the regulations set

  4. Deregulation of the Building Code and the Norwegian Approach to Regulation of Accessibility in the Built Environment.

    Science.gov (United States)

    Lyngstad, Pål

    2016-01-01

    Deregulation is on the political agenda in the European countries. The Norwegian building code related to universal design and accessibility is challenged. To meet this, the Norwegian Building Authority have chosen to examine established truths and are basing their revised code on scientific research and field tests. But will this knowledge-based deregulation comply within the framework of the anti-discrimination act and, and if not: who suffers and to what extent?

  5. Integrating Branding Strategy Across Markets: Building International Brand Architecture

    NARCIS (Netherlands)

    Douglas, S.P.; Craig, S.; Nijssen, E.J.

    2001-01-01

    Brands play a critical role in establishing a firm’s visibility and position in international markets. Building a coherent international brand architecture is a key component of the firm’s overall international marketing strategy, because it provides a structure to leverage strong brands into other

  6. Proposal to change General Consideration 5 and Principle 2 of the International Code of Nomenclature of Prokaryotes.

    Science.gov (United States)

    Oren, Aharon; Garrity, George M

    2014-01-01

    A proposal is submitted to the ICSP to change the wording of General Consideration 5 of the International Code of Nomenclature of Prokaryotes (ICNP), deleting the words Schizophycetes, Cyanophyceae and Cyanobacteria from the groups of organisms whose nomenclature is covered by the Code. It is further proposed to change the terms Zoological Code and International Code of Botanical Nomenclature in General Consideration 5 and in Principle 2 to International Code of Zoological Nomenclature and International Code of Nomenclature for algae, fungi and plants, respectively.

  7. Learning by Doing: Teaching Decision Making through Building a Code of Ethics.

    Science.gov (United States)

    Hawthorne, Mark D.

    2001-01-01

    Notes that applying abstract ethical principles to the practical business of building a code of applied ethics for a technical communication department teaches students that they share certain unarticulated or unconscious values that they can translate into ethical principles. Suggests that combining abstract theory with practical policy writing…

  8. Recommendations for Adopting the International Code of Marketing of Breast-milk Substitutes Into U.S. Policy.

    Science.gov (United States)

    Soldavini, Jessica; Taillie, Lindsey Smith

    2017-08-01

    In 1981, the World Health Organization adopted the International Code of Marketing of Breast-milk Substitutes ( International Code), with subsequent resolutions adopted since then. The International Code contributes to the safe and adequate provision of nutrition for infants by protecting and promoting breastfeeding and ensuring that human milk substitutes, when necessary, are used properly through adequate information and appropriate marketing and distribution. Despite the World Health Organization recommendations for all member nations to implement the International Code in its entirety, the United States has yet to take action to translate it into any national measures. In 2012, only 22.3% of infants in the United States met the American Academy of Pediatrics recommendation of at least 6 months of exclusive breastfeeding. Countries adopting legislation reflecting the provisions of the International Code have seen increases in breastfeeding rates. This article discusses recommendations for translating the International Code into U.S. policy. Adopting legislation that implements, monitors, and enforces the International Code in its entirety has the potential to contribute to increased rates of breastfeeding in the United States, which can lead to improved health outcomes in both infants and breastfeeding mothers.

  9. GATO: an MHD stability code for axisymmetric plasmas with internal separatrices

    International Nuclear Information System (INIS)

    Bernard, L.C.; Helton, F.J.; Moore, R.W.

    1981-07-01

    The GATO code computes the growth rate of ideal magnetohydrodynamic instabilities in axisymmetric geometries with internal separatrices such as doublet and expanded spheromak. The basic method, which uses a variational principle and a Galerkin procedure to obtain a matrix eigenvalue problem, is common to the ERATO and PEST codes. A new coordinate system has been developed to handle the internal separatrix. Efficient algorithms have been developed to solve the matrix eigenvalue problem for matrices of rank as large as 40,000. Further improvement is expected using graph theoretical techniques to reorder the matrices. Using judicious mesh repartition, the marginal point can be determined with great precision. The code has been extensively used to optimize doublet and general tokamak plasmas

  10. Energy and Environment Guide to Action - Chapter 4.3: Building Codes for Energy Efficiency

    Science.gov (United States)

    Provides guidance and recommendations for establishing, implementing, and evaluating state building codes for energy efficiency, which improve energy efficiency in new construction and major renovations. State success stories are included for reference.

  11. International political symbolism of the architecture of government buildings

    Directory of Open Access Journals (Sweden)

    V. V. Kochetkov

    2015-01-01

    Full Text Available The article analyzes international political architecture of government buildings in Russia, the U.S., Western Europe (UK, France, Germany and Asia (China, India, Japan. Conclusions that the architecture of government buildings reflects the values of the dominant society’s political culture. Some government buildings are prototypes constructed previously in other societies and cultural traditions (for instance, the Capitol in Washington, USA, and the Capitoline temple in Rome.

  12. Procedures of ASME code case N-201 for KALIMER. Reactor internal structures

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Yoo, B.

    2001-02-01

    The main objective of this report is to describe the design procedure of ASME Boiler and Pressure Vessel Code, Code Case N-201-4, which is an elevated temperature structural design code of the Nuclear reactor internal structures, checking the criteria of stress limit, accumulated inelastic strain and deformation, creep-fatigue damage, and buckling limit. As one of examples, the creep-fatigue damage evaluations are carried out for the KALIMER reactor internal structures of baffle annulus. This report is expected to be very useful in evaluating the structural integrity of the liquid metal reactor operating under an elevated temperature

  13. Assessment of codes, by-laws and regulations relating to air wells in building design

    Science.gov (United States)

    Fadzil, Sharifah Fairuz Syed; Karamazaman, Nazli

    2017-10-01

    Codes and by-laws concerning air well design (for buildings and lavatories) in Malaysia has been established in the Malaysian Uniform Building By-Laws UBBL number 40 (1) and (2) since the 1980s. Wells are there to fulfill the ventilation and daylighting requirements. The minimum well area according to building storey height are compared between UBBL and the Singapore's well requirements from the Building Construction Authority BCA. A visual and graphical representation (with schematics building and well diagrams drawn to scale) of the minimum well sizes and dimensions is given. It can be seen that if the minimum requirement of well size is used for buildings above 8 storeys high, a thin well resulted which is not proportionate to the building height. A proposed dimension is graphed and given to be used in the UBBL which translated to graphics (3 dimensional buildings drawn to scale) created a much better well proportion.

  14. Energy Code Compliance in a Detailed Commercial Building Sample: The Effects of Missing Data

    Energy Technology Data Exchange (ETDEWEB)

    Biyani, Rahul K.; Richman, Eric E.

    2003-09-30

    Most commercial buildings in the U.S. are required by State or local jurisdiction to meet energy standards. The enforcement of these standards is not well known and building practice without them on a national scale is also little understood. To provide an understanding of these issues, a database has been developed at PNNL that includes detailed energy related building characteristics of 162 commercial buildings from across the country. For this analysis, the COMcheck? compliance software (developed at PNNL) was used to assess compliance with energy codes among these buildings. Data from the database for each building provided the program input with percentage energy compliance to the ASHRAE/IESNA Standard 90.1-1999 energy as the output. During the data input process it was discovered that some essential data for showing compliance of the building envelope was missed and defaults had to be developed to provide complete compliance information. This need for defaults for some data inputs raised the question of what the effect on documenting compliance could be due to missing data. To help answer this question a data collection effort was completed to assess potential differences. Using the program Dodge View, as much of the missing envelope data as possible was collected from the building plans and the database input was again run through COMcheck?. The outputs of both compliance runs were compared to see if the missing data would have adversely affected the results. Both of these results provided a percentage compliance of each building in the envelope and lighting categories, showing by how large a percentage each building either met or fell short of the ASHRAE/IESNA Standard 90.1-1999 energy code. The results of the compliance runs showed that 57.7 % of the buildings met or exceeded envelope requirements with defaults and that 68 % met or exceeded envelope requirements with the actual data. Also, 53.6 % of the buildings met or surpassed the lighting requirements

  15. GATO: An MHD stability code for axisymmetric plasmas with internal separatrices

    International Nuclear Information System (INIS)

    Bernard, L.C.; Helton, F.J.; Moore, R.W.

    1981-01-01

    The GATO code computes the growth rate of ideal magnetohydrodynamic instabilities in axisymmetric geometries with internal separatrices such as doublet and expanded spheromak. The basic method, which uses a variational principle and a Galerkin procedure to obtain a matrix eigenvalue problem, is common to the ERATO and PEST codes. A new coordinate system has been developed to handle the internal separatrix. Efficient algorithms have been developed to solve the matrix eigenvalue problem for matrices of rank as large as 40 000. Further improvement is expected using graph theoretical techniques to reorder the matrices. Using judicious mesh repartition, the marginal point can be determined with great precision. The code has been extensively used to optimize doublet and general tokamak plasmas. (orig.)

  16. Modeling the dynamics of internal flooding - verification analysis

    International Nuclear Information System (INIS)

    Filipov, K.

    2011-01-01

    The results from conducted software WATERFOW's verification analysis, developed for the purposes of reactor building internal flooding analysis have been presented. For the purpose of benchmarking the integrated code MELCOR is selected. Considering the complex structure of reactor building, the sample tests were used to cover the characteristic points of the internal flooding analysis. The inapplicability of MELCOR to the internal flooding study has been proved

  17. Building AN International Polar Data Coordination Network

    Science.gov (United States)

    Pulsifer, P. L.; Yarmey, L.; Manley, W. F.; Gaylord, A. G.; Tweedie, C. E.

    2013-12-01

    In the spirit of the World Data Center system developed to manage data resulting from the International Geophysical Year of 1957-58, the International Polar Year 2007-2009 (IPY) resulted in significant progress towards establishing an international polar data management network. However, a sustained international network is still evolving. In this paper we argue that the fundamental building blocks for such a network exist and that the time is right to move forward. We focus on the Arctic component of such a network with linkages to Antarctic network building activities. A review of an important set of Network building blocks is presented: i) the legacy of the IPY data and information service; ii) global data management services with a polar component (e.g. World Data System); iii) regional systems (e.g. Arctic Observing Viewer; iv) nationally focused programs (e.g. Arctic Observing Viewer, Advanced Cooperative Arctic Data and Information Service, Polar Data Catalogue, Inuit Knowledge Centre); v) programs focused on the local (e.g. Exchange for Local Observations and Knowledge of the Arctic, Geomatics and Cartographic Research Centre). We discuss current activities and results with respect to three priority areas needed to establish a strong and effective Network. First, a summary of network building activities reports on a series of productive meetings, including the Arctic Observing Summit and the Polar Data Forum, that have resulted in a core set of Network nodes and participants and a refined vision for the Network. Second, we recognize that interoperability for information sharing fundamentally relies on the creation and adoption of community-based data description standards and data delivery mechanisms. There is a broad range of interoperability frameworks and specifications available; however, these need to be adapted for polar community needs. Progress towards Network interoperability is reviewed, and a prototype distributed data systems is demonstrated. We

  18. Guide to the Changes between the 2009 and 2012 International Energy Conservation Code

    Energy Technology Data Exchange (ETDEWEB)

    Mapes, Terry S.; Conover, David R.

    2012-05-31

    The International Code Council (ICC) published the 2012 International Energy Conservation Code{reg_sign} (IECC) in early 2012. The 2012 IECC is based on revisions, additions, and deletions to the 2009 IECC that were considered during the ICC code development process conducted in 2011. Solid vertical lines, arrows, or asterisks printed in the 2012 IECC indicate where revisions, deletions, or relocations of text respectively were made to 2009 IECC. Although these marginal markings indicate where changes have been made to the code, they do not provide any further guidance, leaving the reader to consult and compare the 2009 and 2012 IECC for more detail.

  19. Effects of internal and external scatter on the build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation

    International Nuclear Information System (INIS)

    Lin, H.; Wu, DS.; Wu, AD.

    2005-01-01

    The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surface PDD was investigated. The percentage depth doses affected significantly by the external scatter show a larger build-up dose. A forward shifted Dmax depth and a sharper fall-off region compared to PDDs with only internal scatter considered. The surface dose with both internal and external scatter shows a marked decrease at 110 cm SSD, and then slight further changes with the increasing SSD since few external scattered particles from accelerator model can reach the phantom for large SSDs. The sharp PDD increase for the 5 cm x 5 cm field compared to other fields seen when only internal scatter is considered is significantly less when external scatter is also present. The effect of external scatter on surface PDD is more pronounced for large fields than small fields (5 cm x 5 cm field)

  20. An Internal Audit Perspective on Differences between European Corporate Governance Codes and OECD Principles

    Directory of Open Access Journals (Sweden)

    Raluca Ivan

    2015-12-01

    Full Text Available The main purpose of this research is to realize an analysis from an internal audit perspective of European Corporate Governance Codes, in regards with Organization for Economic Cooperation and Development – OECD Principles of Corporate Governance. The research methodology used a classification of countries by legal regime, trying to obtain a global view over the differences between the European corporate governance codes and the OECD Principles provisions, from internal audit’s perspective. The findings suggest that the specificities of internal audit function when studying the differences between European Corporate Governance Codes and OECD Principles lead to different treatment.

  1. Assessment of the Portuguese building thermal code: Newly revised requirements for cooling energy needs used to prevent the overheating of buildings in the summer

    International Nuclear Information System (INIS)

    Oliveira Panao, Marta J.N.; Camelo, Susana M.L.; Goncalves, Helder J.P.

    2011-01-01

    In this paper, cooling energy needs are calculated by the steady-state methodology of the Portuguese building thermal code. After the first period of building code implementation, re-evaluation according to EN ISO 13790 is recommended in order to compare results with the dynamic simulation results. From these analyses, a newly revised methodology arises including a few corrections in procedure. This iterative result is sufficiently accurate to calculate the building's cooling energy needs. Secondly, results show that the required conditions are insufficient to prevent overheating. The use of the gain utilization factor as an overheating risk index is suggested, according to an adaptive comfort protocol, and is integrated in the method used to calculate the maximum value for cooling energy needs. This proposed streamlined method depends on reference values: window-to-floor area ratio, window shading g-value, integrated solar radiation and gain utilization factor, which leads to threshold values significantly below the ones currently used. These revised requirements are more restrictive and, therefore, will act to improve a building's thermal performance during summer. As a rule of thumb applied for Portuguese climates, the reference gain utilization factor should assume a minimum value of 0.8 for a latitude angle range of 40-41 o N, 0.6 for 38-39 o N and 0.5 for 37 o N. -- Highlights: → A newly revised methodology for Portuguese building thermal code. → The use of the gain utilization factor as an overheating risk index is suggested. → The proposed streamlined method depends on reference values. → Threshold maximum values are significantly below the ones currently used.

  2. International Code Centres Network. Summary Report of the Technical Meeting

    International Nuclear Information System (INIS)

    Chung, H-K.

    2011-01-01

    Fifteen international experts on computational aspects of atomic, molecular and particle surface interaction data for fusion energy research participated in the 2nd technical meeting of the International Code Centres Network. Participants reported their research on data production and computational capabilities at their institutions. Experts in the field of plasma modeling of magnetic fusion research joined this meeting to present the data needs and bring the perspective of data users. The interaction and discussion among data producers and data users in this two-day meeting led to an agreement that the scope and function of Code Centres Network should be reformulated to serve the needs of fusion community in more effective way. (author)

  3. [The ICOH International Code of Ethics for Occupational Health Professionals].

    Science.gov (United States)

    Foà, V

    2010-01-01

    In the paper all the steps are described which are followed by ICOH to finalize the International Code of Ethics for Occupational Health Professionals (OHP). The Code is composed by a "Preface" in which is explained why the Occupational Health Professionals need a specific Code different from other Codes built up for general practitioners or other specializations, followed by an "Introduction" where the targets of Occupational Health are underlined and which professionals contribute to achieve the defined target. These two parts are followed by a more substantial description of the tasks and duties of the OHP. In the last part of the Code it is illustrated how to carry out the above mentioned duties. The principles inserted in the ICOH Code of Ethics have been worldwide accepted by the OHP and particularly in Italy where they have been included in the Legislative Decree 81/08.

  4. Building an International Collaboration for GeoInformatics

    Science.gov (United States)

    Snyder, W. S.; Lehnert, K.; Klump, J.

    2005-12-01

    Geoinformatics (cyberinfrastructure for the geosciences) is being developed as a linked system of sites that provide to the Earth science community a library of research data research-grade tools to manipulate, mine, analyze and model interdisciplinary data, and mechanisms to provide the necessary computational resources for these activities. Our science is global in scope and hence, geoinformatics (GI) must be an international effort. How do we build this international GI? What are the main challenges presented by the political, cultural, organizational, and technical diversity of the global science community that we need to address to achieve a truly global cyberinfrastructure for the Geosciences? GI needs to be developed in an internet-like fashion establishing connections among independent globally distributed sites (`nodes') that will share, link, and integrate their data holdings and services. Independence of the GI pieces with respect to goals, scope, and approaches is critical to sustain commitment from people to build a GI node for which they feel ownership and get credit. This should not be fought by funding agencies - and certainly not by state and federal agencies. Communication, coordination, and collaboration are the core efforts to build the connections, but incentives and resources are required to advance and support them. Part of the coordination effort is development and maintenance of standards. Who should set these standards and govern their modification? Do we need an official international body to do so, and should this be a "governing body" or an "advisory body"? What role should international commissions and bodies such as CODATA/ICSU or IUGS-CGI, international societies and unions, the national geological surveys and other federal agencies play? Guidance from the science community is key to construct a system that geo-researchers will want to use, and that meets their needs. Only when the community endorses GI as a fundamental platform to

  5. International codes and agreements to restrict the promotion of harmful products can hold lessons for the control of alcohol marketing.

    Science.gov (United States)

    Landon, Jane; Lobstein, Tim; Godfrey, Fiona; Johns, Paula; Brookes, Chris; Jernigan, David

    2017-01-01

    Background and aims The 2011 UN Summit on Non-Communicable Disease failed to call for global action on alcohol marketing despite calls in the World Health Organization (WHO) Global Action Plan on Non-Communicable Diseases 2013-20 to restrict or ban alcohol advertising. In this paper we ask what it might take to match the global approach to tobacco enshrined in the Framework Convention on Tobacco Control (FCTC), and suggest that public health advocates can learn from the development of the FCTC and the Code of Marketing on infant formula milks and the recent recommendations on restricting food marketing to children. Methods Narrative review of qualitative accounts of the processes that created and monitor existing codes and treaties to restrict the marketing of consumer products, specifically breast milk substitutes, unhealthy foods and tobacco. Findings The development of treaties and codes for market restrictions include: (i) evidence of a public health crisis; (ii) the cost of inaction; (iii) civil society advocacy; (iv) the building of capacity; (v) the management of conflicting interests in policy development; and (vi) the need to consider monitoring and accountability to ensure compliance. Conclusion International public health treaties and codes provide an umbrella under which national governments can strengthen their own legislation, assisted by technical support from international agencies and non-governmental organizations. Three examples of international agreements, those for breast milk substitutes, unhealthy foods and tobacco, can provide lessons for the public health community to make progress on alcohol controls. Lessons include stronger alliances of advocates and health professionals and better tools and capacity to monitor and report current marketing practices and trends. © 2016 Society for the Study of Addiction.

  6. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2012-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  7. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2011-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  8. Earth Sciences' Capacity Building In Developing Countries through International Programmes

    Science.gov (United States)

    Eder, W.

    2007-12-01

    Within the framework of "traditional" programmes, like the joint UNESCO-IUGS "International Geoscience Programme" (IGCP), the "International Continental Scientific Drilling Program" (ICDP), the "Integrated Ocean Drilling Program" (IODP) or the "International Lithosphere Programme" (ILP) numerous opportunities are provided to strengthen postgraduate geo-scientific education of representatives from developing countries. Recently established new initiatives, such as the "International Year of Planet Earth" (IYPE) or UNESCO's Global Network of Geoparks complement these in addition as important components to UNESCO's 'Education for All' programme, notably the youth, as well as to the United Nations Decade of Education for Sustainable Development (2005 - 2014). The "International Year of Planet Earth" is a joint initiative of the International Union of Geological Sciences (IUGS) and UNESCO. The central aims and ambitions of the Year, proclaimed for 2008 by the UN General Assembly, are to demonstrate the great potential of the Earth sciences in building a safer, healthier and wealthier society, and to encourage more widespread and effective application of this potential by targeting politicians and other decision-makers, educational systems, and the general public. Promotion of international collaboration, as well as capacity building and training of students of developing countries in all fields of Earth Sciences seem to be the most appropriate way to meet also the challenges of the IYPE. Another opportunity to improve the international recognition of Earth Scinces, also in developing countries, is the use of Geoparks as a promotional tool for education and popularization of Earth Sciences. Geoparks, notably those included in the European and/or Global Geoparks Networks, provide an international platform of cooperation and exchange between experts and practitioners in geological heritage matters, and are as such excellent instruments in highlighting Earth sciences. The

  9. Description of the COMRADEX code

    International Nuclear Information System (INIS)

    Spangler, G.W.; Boling, M.; Rhoades, W.A.; Willis, C.A.

    1967-01-01

    The COMRADEX Code is discussed briefly and instructions are provided for the use of the code. The subject code was developed for calculating doses from hypothetical power reactor accidents. It permits the user to analyze four successive levels of containment with time-varying leak rates. Filtration, cleanup, fallout and plateout in each containment shell can also be analyzed. The doses calculated include the direct gamma dose from the containment building, the internal doses to as many as 14 organs including the thyroid, bone, lung, etc. from inhaling the contaminated air, and the external gamma doses from the cloud. While further improvements are needed, such as a provision for calculating doses from fallout, rainout and washout, the present code capabilities have a wide range of applicability for reactor accident analysis

  10. Presentation of the International Building Physics Toolbox for Simulink

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Sasic Kalagasidis, Angela; Nielsen, Toke Rammer

    2003-01-01

    The international building physics toolbox (IBPT) is a software library specially constructed for HAM system analysis in building physics. The toolbox is constructed as a modular structure of the standard building elements using the graphical programming language Simulink. Two research groups have...... participated in this project. In order to enable the development of the toolbox, a common modelling platform was defined: a set of unique communication signals, material database and documentation protocol. The IBPT is open source and publicly available on the Internet. Any researcher and student can use...

  11. Code of practice on the international transboundary movement of radioactive waste

    International Nuclear Information System (INIS)

    1990-11-01

    This Code of Practice should serve as guidelines of the IAEA to the States for the development and harmonization of policies and laws on the international transboundary movement of radioactive wastes. It relies on international standards for the safe transport of radioactive material and the physical protection of nuclear material, as well as the standards for basic nuclear safety and radiation protection and radioactive waste management; it does not establish separate guidance in these areas. Furthermore, this Code, which is advisory, does not affect in any way existing and future arrangements among States which relate to matters covered by it and are compatible with its objectives

  12. Comparison of Standard 90.1-2007 and the 2009 IECC with Respect to Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.; Bartlett, Rosemarie; Halverson, Mark A.

    2009-12-11

    The U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP) has been asked by some states and energy code stakeholders to address the comparability of the 2009 International Energy Conservation Code® (IECC) as applied to commercial buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 (hereinafter referred to as Standard 90.1-07). An assessment of comparability will help states respond to and implement conditions specified in the State Energy Program (SEP) Formula Grants American Recovery and Reinvestment Act Funding Opportunity, Number DE-FOA-0000052, and eliminate the need for the states individually or collectively to perform comparative studies of the 2009 IECC and Standard 90.1-07. The funding opportunity announcement contains the following conditions: (2) The State, or the applicable units of local government that have authority to adopt building codes, will implement the following: (A) A residential building energy code (or codes) that meets or exceeds the most recent International Energy Conservation Code, or achieves equivalent or greater energy savings. (B) A commercial building energy code (or codes) throughout the State that meets or exceeds the ANSI/ASHRAE/IESNA Standard 90.1-2007, or achieves equivalent or greater energy savings . (C) A plan to achieve 90 percent compliance with the above energy codes within eight years. This plan will include active training and enforcement programs and annual measurement of the rate of compliance. With respect to item (B) above, many more states, regardless of the edition date, directly adopt the IECC than Standard 90.1-07. This is predominately because the IECC is a model code and part of a coordinated set of model building codes that state and local government have historically adopted to regulate building design and construction. This report compares the 2009 IECC to Standard 90.1-07 with the intent of helping states address whether the adoption and application of the 2009 IECC for commercial

  13. Use of AERIN code for determining internal doses of transuranic isotopes

    International Nuclear Information System (INIS)

    King, W.C.

    1980-01-01

    The AERIN computer code is a mathematical expression of the ICRP Lung Model. The code was developed at the Lawrence Livermore National Laboratory to compute the body organ burdens and absorbed radiation doses resulting from the inhalation of transuranic isotopes and to predict the amount of activity excreted in the urine and feces as a function of time. Over forty cases of internal exposure have been studied using the AERIN code. The code, as modified, has proven to be extremely versatile. The case studies presented demonstrate the excellent correlation that can be obtained between code predictions and observed bioassay data. In one case study a discrepancy was observed between an in vivo count of the whole body and the application of the code using urine and fecal data as input. The discrepancy was resolved by in vivo skull counts that showed the code had predicted the correct skeletal burden

  14. 2nd International Conference on Construction and Building Research

    CERN Document Server

    Fernández-Plazaola, Igor; Hidalgo-Delgado, Francisco; Martínez-Valenzuela, María; Medina-Ramón, Francisco; Oliver-Faubel, Inmaculada; Rodríguez-Abad, Isabel; Salandin, Andrea; Sánchez-Grandia, Rafael; Tort-Ausina, Isabel; Construction and Building Research

    2014-01-01

    Many areas of knowledge converge in the building industry and therefore research in this field necessarily involves an interdisciplinary approach. Effective research requires strong relations between a broad variety of scientific and technological domains and more conventional construction or craft processes, while also considering advanced management processes, where all the main actors permanently interact. This publication takes an interdisciplinary approach grouping various studies on the building industry chosen from among the works presented for the 2nd International Conference on Construction and Building Research. The papers examine aspects of materials and building systems; construction technology; energy and sustainability; construction management; heritage, refurbishment and conservation. The information contained within these pages may be of interest to researchers and practitioners in construction and building activities from the academic sphere, as well as public and private sectors.

  15. Development of safety enhancement technology of containment building

    International Nuclear Information System (INIS)

    Seo, Jeong Moon; Choun, Y. S.; Choi, I. K.

    2002-04-01

    This study consists of four research areas, (1) Seismic safety assessment, (2) Aging assessment of a containment building, (3) Prediction of long-term behavior and analysis of a containment building, (4) Performance verification of a containment building. In the seismic safety assessment area, responses of a containment building were monitored and the analysis method was verified. Also performed are the identification of earthquake characteristics and improvement of the seismic fragility analysis method. In the area of aging assessment of a containment building, we developed aging management code SLMS and database. Aging tests were performed for containment building materials and aging models were developed. Techniques for investigation, detection, and evaluation of aging were developed. In the area of prediction of long-term behavior and analysis of a containment building, we developed a non-linear structural analysis code NUCAS and material models. In the area of performance verification of a containment building, we analyzed the crack behavior of a containment wall and the behavior of the containment under internal pressure. We also improved the ISI methods for prestressed containment

  16. Proposal to consistently apply the International Code of Nomenclature of Prokaryotes (ICNP) to names of the oxygenic photosynthetic bacteria (cyanobacteria), including those validly published under the International Code of Botanical Nomenclature (ICBN)/International Code of Nomenclature for algae, fungi and plants (ICN), and proposal to change Principle 2 of the ICNP.

    Science.gov (United States)

    Pinevich, Alexander V

    2015-03-01

    This taxonomic note was motivated by the recent proposal [Oren & Garrity (2014) Int J Syst Evol Microbiol 64, 309-310] to exclude the oxygenic photosynthetic bacteria (cyanobacteria) from the wording of General Consideration 5 of the International Code of Nomenclature of Prokaryotes (ICNP), which entails unilateral coverage of these prokaryotes by the International Code of Nomenclature for algae, fungi, and plants (ICN; formerly the International Code of Botanical Nomenclature, ICBN). On the basis of key viewpoints, approaches and rules in the systematics, taxonomy and nomenclature of prokaryotes it is reciprocally proposed to apply the ICNP to names of cyanobacteria including those validly published under the ICBN/ICN. For this purpose, a change to Principle 2 of the ICNP is proposed to enable validation of cyanobacterial names published under the ICBN/ICN rules. © 2015 IUMS.

  17. Impact of risk analysis on ITER nuclear buildings internal layout

    International Nuclear Information System (INIS)

    Lignini, F.; Sabathe, L.; Rodriguez-Rodrigo, L.; Uzan-Elbez, J.; Girard, J.-P.

    2006-01-01

    The internal layout of ITER nuclear buildings (Tokamak, Tritium, Hot cell and Radwaste buildings) is the result of an iterative process. Notwithstanding civil engineering requirements, technical and functional requirements for the processes housed in the buildings, the internal layout must also take into account safety requirements and workers protection requirements in normal, incidental and accidental conditions. Potential hazards and constraints result in the definition of various zonings. Each room is classified depending on the level of risk induced by normal and incidental or accidental conditions : - radiological exposure to tritium, and activated products → radiological zoning - exposure to beryllium (vacuum vessel blankets) → beryllium zoning - exposure to electromagnetic fields during plasma shots → electromagnetic zoning - fire hazard : fire compartmentalisation - explosion hazard → anti-blast zoning - waste treatment → waste zoning Prevention of common mode failure due to internal hazards (fire, flooding, load drop ...) for redundant safety important components is also taken into account by geographical separation or by installation of protections between components (either in the same room or preferably when possible by segregation in different rooms). The designer also has to take into account access requirements to equipment and circulation rules for personal, material and substances in ITER nuclear buildings. Risk analyses are performed in the Preliminary Safety Report in order to demonstrate that the layout of ITER nuclear buildings allows to meet the safety objectives and takes into account the requirements associated with the zonings classifications and complies with the regulation. When necessary, modifications are implemented in the design. For example, recent layout modifications were included in the tritium building : utility rooms (electrical supply) were transferred outside the radiological hazard zones. A direct access from the

  18. Breathing (and Coding?) a Bit Easier: Changes to International Classification of Disease Coding for Pulmonary Hypertension.

    Science.gov (United States)

    Mathai, Stephen C; Mathew, Sherin

    2018-04-20

    International Classification of Disease (ICD) coding system is broadly utilized by healthcare providers, hospitals, healthcare payers, and governments to track health trends and statistics at the global, national, and local levels and to provide a reimbursement framework for medical care based upon diagnosis and severity of illness. The current iteration of the ICD system, ICD-10, was implemented in 2015. While many changes to the prior ICD-9 system were included in the ICD-10 system, the newer revision failed to adequately reflect advances in the clinical classification of certain diseases such as pulmonary hypertension (PH). Recently, a proposal to modify the ICD-10 codes for PH was considered and ultimately adopted for inclusion as updates to ICD-10 coding system. While these revisions better reflect the current clinical classification of PH, in the future, further changes should be considered to improve the accuracy and ease of coding for all forms of PH. Copyright © 2018. Published by Elsevier Inc.

  19. ITER [International Thermonuclear Experimental Reactor] reactor building design study

    International Nuclear Information System (INIS)

    Thomson, S.L.; Blevins, J.D.; Delisle, M.W.

    1989-01-01

    The International Thermonuclear Experimental Reactor (ITER) is at the midpoint of a two-year conceptual design. The ITER reactor building is a reinforced concrete structure that houses the tokamak and associated equipment and systems and forms a barrier between the tokamak and the external environment. It provides radiation shielding and controls the release of radioactive materials to the environment during both routine operations and accidents. The building protects the tokamak from external events, such as earthquakes or aircraft strikes. The reactor building requirements have been developed from the component designs and the preliminary safety analysis. The equipment requirements, tritium confinement, and biological shielding have been studied. The building design in progress requires continuous iteraction with the component and system designs and with the safety analysis. 8 figs

  20. Evaluation of internal/external exposure from interior building materials

    International Nuclear Information System (INIS)

    Furuta, Etsuko; Morita-Murase, Yuko; Yoshizawa, Yukio

    2008-01-01

    Internal exposure to alpha particles emitted from 222 Rn (radon) and its daughters is the second leading cause of lung cancer. As a source of indoor radon in home, there are interior building materials that contain radioactive minerals. These radioactive consumer products have been claimed by distributors to have effect of 'minus-ion' or 'radon spring' for healthy promotion. We analyzed radioactive nuclides contained in the interior building materials, and measured radon levels released from them. The results of gamma-ray spectrometry revealed that these interior building materials contain U- and Th-series nuclides. The densities of some radioactive nuclides in the tile used for a bathroom exceeded the exempt limits of International Basic Safety Standards. However, the radon densities released from the tile was lower than detectable limit. In contrast, one of the wallpaper released 34 Bq·m -3 of radon gas in a 50-liter container. This value is two times higher than the average radon level in Japanese homes. The minus-ion effect' wallpapers are thought to be a cause of residential exposure to radon. (author)

  1. 24 CFR 200.925c - Model codes.

    Science.gov (United States)

    2010-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  2. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-2001 as the Commercial Building Energy Code in Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Winiarski, David W.; Belzer, David B.; Richman, Eric E.

    2004-09-30

    ASHRAE Standard 90.1-2001 Energy Standard for Buildings except Low-Rise Residential Buildings (hereafter referred to as ASHRAE 90.1-2001 or 90.1-2001) was developed in an effort to set minimum requirements for the energy efficient design and construction of new commercial buildings. The State of Tennessee is considering adopting ASHRAE 90.1-2001 as its commercial building energy code. In an effort to evaluate whether or not this is an appropriate code for the state, the potential benefits and costs of adopting this standard are considered in this report. Both qualitative and quantitative benefits and costs are assessed. Energy and economic impacts are estimated using the Building Loads Analysis and System Thermodynamics (BLAST) simulations combined with a Life-Cycle Cost (LCC) approach to assess corresponding economic costs and benefits. Tennessee currently has ASHRAE Standard 90A-1980 as the statewide voluntary/recommended commercial energy standard; however, it is up to the local jurisdiction to adopt this code. Because 90A-1980 is the recommended standard, many of the requirements of ASHRAE 90A-1980 were used as a baseline for simulations.

  3. International transitional administrations and the politics of authority building

    OpenAIRE

    Zaum, Dominik

    2017-01-01

    This article critically examines authority-building practices in the context of statebuilding through the lens of one particular form of external statebuilding interventions: international transitional administrations (ITAs), which are established by international organisations (mainly the UN) to exercise governmental functions over a territory, and in some cases to engage in the establishment or reform of political, administrative, and economic institutions. Drawing in particular on one ITA,...

  4. INCAS residential building energy savings design code: User's guide. INCAS: guida all'uso del codice di calcolo di diagnosi energetica nell'abitazione

    Energy Technology Data Exchange (ETDEWEB)

    Carderi, A.

    1991-01-01

    The INCAS residential building energy savings design code comes complete with data banks giving designers all the necessary technical and economic information and energy savings options for the code's efficacious application to obtain the optimum energy efficient/cost beneficial solution. This user's manual contains descriptions of the types of data to be input, the code's methodology, the data banks, and complete instructions for the code's implementation. The energy savings alternatives include: choice of heating plant and fuel; choice, application location and thickness of thermal insulation. For the case of building heating system retrofits, the code takes into account the existing condition of building components.

  5. Locally orderless registration code

    DEFF Research Database (Denmark)

    2012-01-01

    This is code for the TPAMI paper "Locally Orderless Registration". The code requires intel threadding building blocks installed and is provided for 64 bit on mac, linux and windows.......This is code for the TPAMI paper "Locally Orderless Registration". The code requires intel threadding building blocks installed and is provided for 64 bit on mac, linux and windows....

  6. Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions for Buildings in 2016 and Later

    Energy Technology Data Exchange (ETDEWEB)

    Deru, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Field-Macumber, Kristin [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code (IRC) enacted in Section 1331 of the 2005 Energy Policy Act (EPAct) of 2005, noted in Internal Revenue Service (IRS) Notices 2006-52 (IRS 2006), 2008-40 (IRS 2008) and 2012-26 (IRS 2012), and updated by the Protecting Americans from Tax Hikes (PATH) Act of 2015. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning (HVAC); and service hot water (SHW) systems. This document applies to buildings placed in service on or after January 1, 2016.

  7. Energy conservation according to the building codes of the National Board of Housing, Building and Planning; Energihushaallning enligt Boverkets byggregler

    Energy Technology Data Exchange (ETDEWEB)

    2009-10-15

    To comply with international and national targets for energy use, the National Board has adopted rules setting the levels to be met in order to conserve energy in buildings. The rules for buildings are shown in Boverkets building regulations (BBR). The BBR lists comprehensive requirements in order to ensure that a building must not use more than a certain number of kilowatt hours per square meter and year. There are more detailed requirements for thermal insulation, heating, cooling and air conditioning installations, efficient use of electricity and installation of metering systems for monitoring of building energy. The latest version of the BBR came into force on February 1, 2009 and has more stringent requirements for the buildings heated by electricity or comfort cooling powered by electricity. This handbook presents comments and answers to questions about the new rules for energy conservation. It replaces our previous handbook 'Thermal calculations'

  8. Internal structure of reactor building for Madras Atomic Power Project

    International Nuclear Information System (INIS)

    Pandit, D.P.

    1975-01-01

    The structural configuration and analysis of structural elements of the internal structure of reactor building for the Madras Atomic Power Project has been presented. Two methods of analysis of the internal structure, viz. Equivalent Plane Frame and Finite Element Method, are explained and compared with the use of bending moments obtained. (author)

  9. An Internal Audit Perspective on Differences between European Corporate Governance Codes and OECD Principles

    OpenAIRE

    Raluca Ivan

    2015-01-01

    The main purpose of this research is to realize an analysis from an internal audit perspective of European Corporate Governance Codes, in regards with Organization for Economic Cooperation and Development – OECD Principles of Corporate Governance. The research methodology used a classification of countries by legal regime, trying to obtain a global view over the differences between the European corporate governance codes and the OECD Principles provisions, from internal audit’s perspective. T...

  10. Reconciliation of international administrative coding systems for comparison of colorectal surgery outcome.

    Science.gov (United States)

    Munasinghe, A; Chang, D; Mamidanna, R; Middleton, S; Joy, M; Penninckx, F; Darzi, A; Livingston, E; Faiz, O

    2014-07-01

    Significant variation in colorectal surgery outcomes exists between different countries. Better understanding of the sources of variable outcomes using administrative data requires alignment of differing clinical coding systems. We aimed to map similar diagnoses and procedures across administrative coding systems used in different countries. Administrative data were collected in a central database as part of the Global Comparators (GC) Project. In order to unify these data, a systematic translation of diagnostic and procedural codes was undertaken. Codes for colorectal diagnoses, resections, operative complications and reoperative interventions were mapped across the respective national healthcare administrative coding systems. Discharge data from January 2006 to June 2011 for patients who had undergone colorectal surgical resections were analysed to generate risk-adjusted models for mortality, length of stay, readmissions and reoperations. In all, 52 544 case records were collated from 31 institutions in five countries. Mapping of all the coding systems was achieved so that diagnosis and procedures from the participant countries could be compared. Using the aligned coding systems to develop risk-adjusted models, the 30-day mortality rate for colorectal surgery was 3.95% (95% CI 0.86-7.54), the 30-day readmission rate was 11.05% (5.67-17.61), the 28-day reoperation rate was 6.13% (3.68-9.66) and the mean length of stay was 14 (7.65-46.76) days. The linkage of international hospital administrative data that we developed enabled comparison of documented surgical outcomes between countries. This methodology may facilitate international benchmarking. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  11. Seismic Safety Of Simple Masonry Buildings

    International Nuclear Information System (INIS)

    Guadagnuolo, Mariateresa; Faella, Giuseppe

    2008-01-01

    Several masonry buildings comply with the rules for simple buildings provided by seismic codes. For these buildings explicit safety verifications are not compulsory if specific code rules are fulfilled. In fact it is assumed that their fulfilment ensures a suitable seismic behaviour of buildings and thus adequate safety under earthquakes. Italian and European seismic codes differ in the requirements for simple masonry buildings, mostly concerning the building typology, the building geometry and the acceleration at site. Obviously, a wide percentage of buildings assumed simple by codes should satisfy the numerical safety verification, so that no confusion and uncertainty have to be given rise to designers who must use the codes. This paper aims at evaluating the seismic response of some simple unreinforced masonry buildings that comply with the provisions of the new Italian seismic code. Two-story buildings, having different geometry, are analysed and results from nonlinear static analyses performed by varying the acceleration at site are presented and discussed. Indications on the congruence between code rules and results of numerical analyses performed according to the code itself are supplied and, in this context, the obtained result can provide a contribution for improving the seismic code requirements

  12. International filiation in the new Civil and Commercial Code of Argentina

    Directory of Open Access Journals (Sweden)

    Luciana BEATRIZ SCOTTI

    2015-07-01

    Full Text Available The Argentine Private International Law omitted from yesteryear, legislate on international filiation, both in relation to jurisdiction and applicable law in matters of contesting paternity, establishment and recognition of parentage as regards the extraterritorial recognition of parental filiation. Indeed, given the particularities of this issue, the responses from our discipline were delayed. The Argentina did not have regulation of internal source, and conventional rules are scarce and inadequate for today.In comparative law and in a wide sector of the national and foreign doctrine, the tendency is to adopt a connecting element focused on the child: his domicile or habitual residence, with some nuances of different interpretation and potential accumulation of laws. Also on jurisdiction, we note a clear orientation towards the opening of forums available.In the present work, we try to provide some guidelines for coding this sensitive issue, which involves primarily the human rights of children, with special consideration the provisions of the recently adopted Civil and Commercial Code of Argentina, and the current context in which the techniques of assisted human reproduction claim a starring role, with serious and concrete effects on Private International Law.

  13. Analysis of Potential Benefits and Costs of Updating the Commercial Building Energy Code in North Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Winiarski, David W.; Richman, Eric E.

    2004-04-30

    The state of North Dakota is considering updating its commercial building energy code. This report evaluates the potential costs and benefits to North Dakota residents from updating and requiring compliance with ASHRAE Standard 90.1-2001. Both qualitative and quantitative benefits and costs are assessed in the analysis. Energy and economic impacts are estimated using the Building Loads Analysis and System Thermodynamics (BLAST simulation combined with a Life-cycle Cost (LCC) approach to assess correspodning economic costs and benefits.

  14. International piping benchmarks: Use of simplified code PACE 2

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)

    1979-06-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  15. International piping benchmarks: Use of simplified code PACE 2

    International Nuclear Information System (INIS)

    Boyle, J.; Spence, J.; Blundell, C.

    1979-01-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  16. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    Science.gov (United States)

    Toprak, A. Emre; Gülay, F. Gülten; Ruge, Peter

    2008-07-01

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 m×7.80 m = 127.90 m2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher

  17. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    International Nuclear Information System (INIS)

    Toprak, A. Emre; Guelay, F. Guelten; Ruge, Peter

    2008-01-01

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m 2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher

  18. Lessons learned from new construction utility demand side management programs and their implications for implementing building energy codes

    Energy Technology Data Exchange (ETDEWEB)

    Wise, B.K.; Hughes, K.R.; Danko, S.L.; Gilbride, T.L.

    1994-07-01

    This report was prepared for the US Department of Energy (DOE) Office of Codes and Standards by the Pacific Northwest Laboratory (PNL) through its Building Energy Standards Program (BESP). The purpose of this task was to identify demand-side management (DSM) strategies for new construction that utilities have adopted or developed to promote energy-efficient design and construction. PNL conducted a survey of utilities and used the information gathered to extrapolate lessons learned and to identify evolving trends in utility new-construction DSM programs. The ultimate goal of the task is to identify opportunities where states might work collaboratively with utilities to promote the adoption, implementation, and enforcement of energy-efficient building energy codes.

  19. Inventory of U.S.-led International Activities on Building Energy Efficiency Initial Findings

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, Alison; Evans, Meredydd

    2010-04-01

    Several U.S. Government agencies promote energy efficiency in buildings internationally. The types and scope of activities vary by agency. Those with the largest role include the U.S. Agency for International Development (USAID), the U.S. Department of State and the Environmental Protection Agency (EPA). Both USAID and the Department of State have a substantial presence overseas, which may present some complementarities with the Department of Energy’s efforts to reach out to other countries. Generally speaking, USAID focuses on capacity building and policy issues; the Department of State focuses on broad diplomatic efforts and some targeted grants in support of these efforts, and EPA has more targeted roles linked to ENERGY STAR appliances and a few other activities. Several additional agencies are also involved in trade-related efforts to promote energy efficiency in buildings. These include the Department of Commerce, the Export-Import Bank, the Overseas Private Investment Corporation and the Trade and Development Agency (TDA). This initial synthesis report is designed to summarize broad trends and activities relating to international cooperation on energy efficiency in buildings, which can help the U.S. Department of Energy (DOE) in developing its own strategy in this area. The Pacific Northwest National Laboratory will develop a more complete synthesis report later in 2010 as it populates a database on international projects on building energy efficiency.

  20. Business Ethics: International Analysis of Codes of Ethics and Conduct

    Directory of Open Access Journals (Sweden)

    Josmar Andrade

    2017-03-01

    Full Text Available Codes of ethics and code of conduct formalize an ideal of expected behavior patterns to managers and employees of organizations, providing standards and orientation that states companies interactions with the community, through products /services, sales force, marketing communications, investments, and relationships with other stakeholders, influencing company reputation and overall Marketing performance. The objective of this study is to analyze the differences in codes of ethics of the largest companies based in Brazil and in Portugal, given their cultural and linguistic similarities. Findings show that the use of codes of ethics are more common in Brazil than in Portugal and that codes of ethics are substantially more extensive and cover a larger number of categories in Brazilian companies, reflecting the organizations’ mission and perception of stakeholders concerns and priorities. We conclude that ethical issues severely impact company reputation and, in a comprehensive sense, overall Marketing performance. Marketing professionals should be systematically aware of how company core values are transmitted to different audiences, including the use of code of ethics to communicate both with internal and external publics. 0 0 1 171 966 CASA DOS ANDRADES 23 14 1123 14.0 96 800x600 Normal 0 false false false EN-US JA X-NONE  

  1. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Halverson, Mark A.; Richman, Eric E.; Winiarski, David W.

    2002-09-30

    The state of Michigan is considering adpoting ASHRAE 90.1-1999 as its commercial building energy code. In an effort to evaluate whether or not this is an appropraite code for the state, the potential benefits and costs of adopting this standard are considered. Both qualitative and quantitative benefits are assessed. The energy simulation and economic results suggest that adopting ASHRAE 90.1-1999 would provide postitive net benefits to the state relative to the building and design requirements currently in place.

  2. Radioactive action code

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    A new coding system, 'Hazrad', for buildings and transportation containers for alerting emergency services personnel to the presence of radioactive materials has been developed in the United Kingdom. The hazards of materials in the buildings or transport container, together with the recommended emergency action, are represented by a number of codes which are marked on the building or container and interpreted from a chart carried as a pocket-size guide. Buildings would be marked with the familiar yellow 'radioactive' trefoil, the written information 'Radioactive materials' and a list of isotopes. Under this the 'Hazrad' code would be written - three symbols to denote the relative radioactive risk (low, medium or high), the biological risk (also low, medium or high) and the third showing the type of radiation emitted, alpha, beta or gamma. The response cards indicate appropriate measures to take, eg for a high biological risk, Bio3, the wearing of a gas-tight protection suit is advised. The code and its uses are explained. (U.K.)

  3. International Code Assessment and Applications Program: Summary of code assessment studies concerning RELAP5/MOD2, RELAP5/MOD3, and TRAC-B

    International Nuclear Information System (INIS)

    Schultz, R.R.

    1993-12-01

    Members of the International Code Assessment Program (ICAP) have assessed the US Nuclear Regulatory Commission (USNRC) advanced thermal-hydraulic codes over the past few years in a concerted effort to identify deficiencies, to define user guidelines, and to determine the state of each code. The results of sixty-two code assessment reviews, conducted at INEL, are summarized. Code deficiencies are discussed and user recommended nodalizations investigated during the course of conducting the assessment studies and reviews are listed. All the work that is summarized was done using the RELAP5/MOD2, RELAP5/MOD3, and TRAC-B codes

  4. VS30 – A site-characterization parameter for use in building Codes, simplified earthquake resistant design, GMPEs, and ShakeMaps

    Science.gov (United States)

    Borcherdt, Roger D.

    2012-01-01

    VS30, defined as the average seismic shear-wave velocity from the surface to a depth of 30 meters, has found wide-spread use as a parameter to characterize site response for simplified earthquake resistant design as implemented in building codes worldwide. VS30 , as initially introduced by the author for the US 1994 NEHRP Building Code, provides unambiguous definitions of site classes and site coefficients for site-dependent response spectra based on correlations derived from extensive borehole logging and comparative ground-motion measurement programs in California. Subsequent use of VS30 for development of strong ground motion prediction equations (GMPEs) and measurement of extensive sets of VS borehole data have confirmed the previous empirical correlations and established correlations of SVS30 with VSZ at other depths. These correlations provide closed form expressions to predict S30 V at a large number of additional sites and further justify S30 V as a parameter to characterize site response for simplified building codes, GMPEs, ShakeMap, and seismic hazard mapping.

  5. Manual for IRS Coding. Joint IAEA/NEA International Reporting System for Operating Experience

    International Nuclear Information System (INIS)

    2011-01-01

    The International Reporting System for Operating Experience (IRS) is jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). In early 2010, the IAEA and OECD/NEA jointly issued the IRS Guidelines, which described the reporting system and process and gave users the necessary elements to enable them to produce IRS reports to a high standard of quality while retaining the effectiveness of the system expected by all Member States operating nuclear power plants. The purpose of the present Manual for IRS Coding is to provide supplementary guidance specifically on the coding element of IRS reports to ensure uniform coding of events that are reported through IRS. This Coding Manual does not supersede the IRS Guidelines, but rather, supports users and preparers in achieving a consistent and high level of quality in their IRS reports. Consistency and high quality in the IRS reports allow stakeholders to search and retrieve specific event information with ease. In addition, well-structured reports also enhance the efficient management of the IRS database. This Coding Manual will give specific guidance on the application of each section of the IRS codes, with examples where necessary, of when and how these codes are to be applied. As this reporting system is owned by the Member States, this manual has been developed and approved by the IRS National Coordinators with the assistance of the IAEA and NEA secretariats

  6. Radiation dosimetry with plane-parallel ionization chambers: An international (IAEA) code of practice

    International Nuclear Information System (INIS)

    Andreo, P.

    1996-01-01

    Research on plane-parallel ionization chambers since the IAEA Code of Practice (TRS-277) was published in 1987 has expanded our knowledge on perturbation and other correction factors in ionization chamber dosimeter, and also constructional details of these chambers have been shown to be important. Different national organizations have published, or are in the process of publishing, recommendations on detailed procedures for the calibration and use of plane-parallel ionization chambers. An international working group was formed under the auspices of the IAEA, first to assess the status and validity of IAEA TRS-277, and second to develop an international Code of Practice for the calibration and use of plane-parallel ionization chambers in high-energy electron and photon beams. The purpose of this work is to describe the forthcoming Code of Practice. (author). 39 refs, 3 figs, 2 tabs

  7. Radiation dosimetry with plane-parallel ionization chambers: An international (IAEA) code of practice

    Energy Technology Data Exchange (ETDEWEB)

    Andreo, P [Lunds Hospital, Lund (Sweden). Radiophysics Dept.; Almond, P R [J.G. Brown Cancer Center, Univ. of Lousville, Lousville, KY (United States). Dept. of Radiation Oncology; Mattsson, O [Sahlgrenska Hospital, Gothenburg (Sweden). Dept. of Radiation Physics; Nahum, A E [Royal Marsden Hospital, Sutton (United Kingdom). Joint Dept. of Physics; Roos, M [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1996-08-01

    Research on plane-parallel ionization chambers since the IAEA Code of Practice (TRS-277) was published in 1987 has expanded our knowledge on perturbation and other correction factors in ionization chamber dosimeter, and also constructional details of these chambers have been shown to be important. Different national organizations have published, or are in the process of publishing, recommendations on detailed procedures for the calibration and use of plane-parallel ionization chambers. An international working group was formed under the auspices of the IAEA, first to assess the status and validity of IAEA TRS-277, and second to develop an international Code of Practice for the calibration and use of plane-parallel ionization chambers in high-energy electron and photon beams. The purpose of this work is to describe the forthcoming Code of Practice. (author). 39 refs, 3 figs, 2 tabs.

  8. Sustainability in Energy and Buildings : Proceedings of the 3rd International Conference in Sustainability in Energy and Buildings

    CERN Document Server

    Namaane, Aziz; Howlett, Robert; Jain, Lakhmi

    2012-01-01

    Welcome to the proceedings of the Third International Conference on Sustainability in Energy and Buildings, SEB’11, held in Marseilles in France, organised by the Laboratoire des Sciences del'Information et des Systèmes (LSIS) in Marseille, France in partnership with KES International.   SEB'11 formed a welcome opportunity for researchers in subjects related to sustainability, renewable energy technology, and applications in the built environment to mix with other scientists, industrialists and stakeholders in the field.   The conference featured presentations on a range of renewable energy and sustainability related topics. In addition the conference explored two innovative themes: - the application of intelligent sensing, control, optimisation and modelling techniques to sustainability and - the technology of sustainable buildings.  These two themes combine synergetically to address issues relating to The Intelligent Building.   SEB’11 attracted a significant number of submissions from around the w...

  9. RESRAD-BUILD verification

    International Nuclear Information System (INIS)

    Kamboj, S.; Yu, C.; Biwer, B. M.; Klett, T.

    2002-01-01

    The results generated by the RESRAD-BUILD code (version 3.0) were verified with hand or spreadsheet calculations using equations given in the RESRAD-BUILD manual for different pathways. For verification purposes, different radionuclides--H-3, C-14, Na-22, Al-26, Cl-36, Mn-54, Co-60, Au-195, Ra-226, Ra-228, Th-228, and U-238--were chosen to test all pathways and models. Tritium, Ra-226, and Th-228 were chosen because of the special tritium and radon models in the RESRAD-BUILD code. Other radionuclides were selected to represent a spectrum of radiation types and energies. Verification of the RESRAD-BUILD code was conducted with an initial check of all the input parameters for correctness against their original source documents. Verification of the calculations was performed external to the RESRAD-BUILD code with Microsoft Excel to verify all the major portions of the code. In some cases, RESRAD-BUILD results were compared with those of external codes, such as MCNP (Monte Carlo N-particle) and RESRAD. The verification was conducted on a step-by-step basis and used different test cases as templates. The following types of calculations were investigated: (1) source injection rate, (2) air concentration in the room, (3) air particulate deposition, (4) radon pathway model, (5) tritium model for volume source, (6) external exposure model, (7) different pathway doses, and (8) time dependence of dose. Some minor errors were identified in version 3.0; these errors have been corrected in later versions of the code. Some possible improvements in the code were also identified

  10. Ethical Guidelines for Structural Interventions to Small-Scale Historic Stone Masonry Buildings.

    Science.gov (United States)

    Hurol, Yonca; Yüceer, Hülya; Başarır, Hacer

    2015-12-01

    Structural interventions to historic stone masonry buildings require that both structural and heritage values be considered simultaneously. The absence of one of these value systems in implementation can be regarded as an unethical professional action. The research objective of this article is to prepare a guideline for ensuring ethical structural interventions to small-scale stone historic masonry buildings in the conservation areas of Northern Cyprus. The methodology covers an analysis of internationally accepted conservation documents and national laws related to the conservation of historic buildings, an analysis of building codes, especially Turkish building codes, which have been used in Northern Cyprus, and an analysis of the structural interventions introduced to a significant historic building in a semi-intact state in the walled city of Famagusta. This guideline covers issues related to whether buildings are intact or ruined, the presence of earthquake risk, the types of structural decisions in an architectural conservation project, and the values to consider during the decision making phase.

  11. Building guide : how to build Xyce from source code.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric Richard; Russo, Thomas V.; Schiek, Richard Louis; Sholander, Peter E.; Thornquist, Heidi K.; Mei, Ting; Verley, Jason C.

    2013-08-01

    While Xyce uses the Autoconf and Automake system to configure builds, it is often necessary to perform more than the customary %E2%80%9C./configure%E2%80%9D builds many open source users have come to expect. This document describes the steps needed to get Xyce built on a number of common platforms.

  12. Internal heat gain from different light sources in the building lighting systems

    Directory of Open Access Journals (Sweden)

    Suszanowicz Dariusz

    2017-01-01

    Full Text Available EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.

  13. Internal heat gain from different light sources in the building lighting systems

    Science.gov (United States)

    Suszanowicz, Dariusz

    2017-10-01

    EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output) were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.

  14. FPFPspace2: A code for following airborne fission products in generic nuclear plant flow paths

    International Nuclear Information System (INIS)

    Owcarski, P.C.; Burk, K.W.; Ramsdell, J.V.; Yasuda, D.D.

    1991-03-01

    In order to assure that a nuclear power plant control room remains habitable during certain types of postulated accidents, Pacific Northwest Laboratory (PNL) has undertaken a special study for the US Nuclear Regulatory Commission. This purpose of this study is to develop software that can aid in the analyses of control room habitability during accidents in which airborne fission products could challenge internal air pathways to the control room. PNL has completed an initial version (FPFP) and final version (FPFP 2) of a software package that can estimate the unsteady-state invasion of quantities of fission products into the control room or any other destination within the nuclear plant via generic internal flow paths. This report consists of three parts: Section 2.0, Technical Bases, describes the flow path components and mechanisms of natural fission product deposition; Section 3.0, FPFP 2 Code Description, describes code organization and the functions of the subroutines; and Section 4.0, Code Operation, discusses details of input requirements, code output, and a sample case demonstration. The appendices consist of an FPFP 2 Fortran code listing, a listing of a code for building input files, forms for building input files, and the sample case input and output files. 7 refs., 3 figs

  15. Schrödinger's killer app race to build the world's first quantum computer

    CERN Document Server

    Dowling, Jonathan P

    2013-01-01

    The race is on to construct the first quantum code breaker, as the winner will hold the key to the entire Internet. From international, multibillion-dollar financial transactions to top-secret government communications, all would be vulnerable to the secret-code-breaking ability of the quantum computer. Written by a renowned quantum physicist closely involved in the U.S. government's development of quantum information science, Schrodinger's Killer App: Race to Build the World's First Quantum Computer presents an inside look at the government's quest to build a quantum computer capable of solvi

  16. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    Science.gov (United States)

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  17. 76 FR 37034 - Certain Employee Remuneration in Excess of $1,000,000 Under Internal Revenue Code Section 162(m)

    Science.gov (United States)

    2011-06-24

    ... Certain Employee Remuneration in Excess of $1,000,000 Under Internal Revenue Code Section 162(m) AGENCY... remuneration in excess of $1,000,000 under the Internal Revenue Code (Code). The proposed regulations clarify... stock options, it is intended that the directors may retain discretion as to the exact number of options...

  18. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  19. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-09-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  20. Qualification and application of nuclear reactor accident analysis code with the capability of internal assessment of uncertainty

    International Nuclear Information System (INIS)

    Borges, Ronaldo Celem

    2001-10-01

    This thesis presents an independent qualification of the CIAU code ('Code with the capability of - Internal Assessment of Uncertainty') which is part of the internal uncertainty evaluation process with a thermal hydraulic system code on a realistic basis. This is done by combining the uncertainty methodology UMAE ('Uncertainty Methodology based on Accuracy Extrapolation') with the RELAP5/Mod3.2 code. This allows associating uncertainty band estimates with the results obtained by the realistic calculation of the code, meeting licensing requirements of safety analysis. The independent qualification is supported by simulations with RELAP5/Mod3.2 related to accident condition tests of LOBI experimental facility and to an event which has occurred in Angra 1 nuclear power plant, by comparison with measured results and by establishing uncertainty bands on safety parameter calculated time trends. These bands have indeed enveloped the measured trends. Results from this independent qualification of CIAU have allowed to ascertain the adequate application of a systematic realistic code procedure to analyse accidents with uncertainties incorporated in the results, although there is an evident need of extending the uncertainty data base. It has been verified that use of the code with this internal assessment of uncertainty is feasible in the design and license stages of a NPP. (author)

  1. Building America Best Practices Series: Volume 7.1: Guide to Determining Climate Regions by County

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, Michael C.; Williamson, Jennifer L.; Gilbride, Theresa L.; Cole, Pamala C.; Hefty, Marye G.; Love, Pat M.

    2010-08-30

    This report for DOE's Building America program helps builders identify which Building America climate region they are building in. The guide includes maps comparing the Building America regions with climate designations used in the International Energy Conservation Code for Residential Buildings and lists all U.S. counties by climate zone. A very brief history of the development of the Building America climate map and descriptions of each climate zone are provided. This report is available on the Building America website www.buildingamerica.gov.

  2. INLUX-DBR - A calculation code to calculate indoor natural illuminance inside buildings under various sky conditions

    International Nuclear Information System (INIS)

    Ferraro, V.; Igawa, N.; Marinelli, V.

    2010-01-01

    A calculation code, named INLUX-DBR, is presented, which is a modified version of INLUX code, able to predict the illuminance distribution on the inside surfaces of a room with six walls and a window, and on the work plane. At each desired instant the code solves the system of the illuminance equations of each surface element, characterized by the latter's reflection coefficient and its view factors toward the other elements. In the model implemented in the code, the sky-diffuse luminance distribution, the sun beam light and the light reflected from the ground toward the room are considered. The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, in various sky conditions of overcast, clear and intermediate days. The validation is performed using the sky luminance data measured by a sky scanner and the measured beam illuminance of the sun as input data. A comparative analysis of some of the well-known calculation models of sky luminance, namely Perez, Igawa and CIE models was also carried out, comparing the code predictions and the measured values of inside illuminance in the scale model.

  3. Energy Efficiency Building Code for Commercial Buildings in Sri Lanka

    Energy Technology Data Exchange (ETDEWEB)

    Busch, John; Greenberg, Steve; Rubinstein, Francis; Denver, Andrea; Rawner, Esther; Franconi, Ellen; Huang, Joe; Neils, Danielle

    2000-09-30

    1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.

  4. Energy Efficiency Building Code for Commercial Buildings in Sri Lanka

    International Nuclear Information System (INIS)

    Busch, John; Greenberg, Steve; Rubinstein, Francis; Denver, Andrea; Rawner, Esther; Franconi, Ellen; Huang, Joe; Neils, Danielle

    2000-01-01

    1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards

  5. PIConGPU - How to build one of the fastest GPU particle-in-cell codes in the world

    Energy Technology Data Exchange (ETDEWEB)

    Burau, Heiko; Debus, Alexander; Helm, Anton; Huebl, Axel; Kluge, Thomas; Widera, Rene; Bussmann, Michael; Schramm, Ulrich; Cowan, Thomas [HZDR, Dresden (Germany); Juckeland, Guido; Nagel, Wolfgang [TU Dresden (Germany); ZIH, Dresden (Germany); Schmitt, Felix [NVIDIA (United States)

    2013-07-01

    We present the algorithmic building blocks of PIConGPU, one of the fastest implementations of the particle-in-cell algortihm on GPU clusters. PIConGPU is a highly-scalable, 3D3V electromagnetic PIC code that is used in laser plasma and astrophysical plasma simulations.

  6. Training program for energy conservation in new building construction. Volume III. Energy conservation technology for plan examiners and code administrators. Energy Conservation Technology Series 200

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    Under the sponsorship of the United States Department of Energy, a Model Code for Energy Conservation in New Building Construction has been developed by those national organizations primarily concerned with the development and promulgation of model codes. The technical provisions are based on ASHRAE Standard 90-75 and are intended for use by state and local officials. The subject of regulation of new building construction to assure energy conservation is recognized as one in which code officials have not had previous exposure. It was also determined that application of the model code would be made at varying levels by officials with both a specific requirement for knowledge and a differing degree of prior training in the state-of-the-art. Therefore, a training program and instructional materials were developed for code officials to assist them in the implementation and enforcement of energy efficient standards and codes. The training program for Energy Conservation Tehnology for Plan Examiners and Code Administrators (ECT Series 200) is presented.

  7. International standards: the World Organisation for Animal Health Terrestrial Animal Health Code.

    Science.gov (United States)

    Thiermann, A B

    2015-04-01

    This paper provides a description of the international standards contained in the TerrestrialAnimal Health Code of the World Organisation for Animal Health (OIE) that relate to the prevention and control of vector-borne diseases. It identifies the rights and obligations of OIE Member Countries regarding the notification of animal disease occurrences, as well as the recommendations to be followed for a safe and efficient international trade of animals and their products.

  8. Interrelations of codes in human semiotic systems.

    OpenAIRE

    Somov, Georgij

    2016-01-01

    Codes can be viewed as mechanisms that enable relations of signs and their components, i.e., semiosis is actualized. The combinations of these relations produce new relations as new codes are building over other codes. Structures appear in the mechanisms of codes. Hence, codes can be described as transformations of structures from some material systems into others. Structures belong to different carriers, but exist in codes in their "pure" form. Building of codes over other codes fosters t...

  9. Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edelson, Jim [New Buildings Inst. (NBI), Portland, OR (United States); Lyles, Mark [New Buildings Inst. (NBI), Portland, OR (United States)

    2018-01-20

    This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New

  10. INLUX-DBR - A calculation code to calculate indoor natural illuminance inside buildings under various sky conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ferraro, V.; Igawa, N.; Marinelli, V. [Mechanical Engineering Department, University of Calabria, 87036 Arcavacata di Rende (CS) (Italy)

    2010-09-15

    A calculation code, named INLUX-DBR, is presented, which is a modified version of INLUX code, able to predict the illuminance distribution on the inside surfaces of a room with six walls and a window, and on the work plane. At each desired instant the code solves the system of the illuminance equations of each surface element, characterized by the latter's reflection coefficient and its view factors toward the other elements. In the model implemented in the code, the sky-diffuse luminance distribution, the sun beam light and the light reflected from the ground toward the room are considered. The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, in various sky conditions of overcast, clear and intermediate days. The validation is performed using the sky luminance data measured by a sky scanner and the measured beam illuminance of the sun as input data. A comparative analysis of some of the well-known calculation models of sky luminance, namely Perez, Igawa and CIE models was also carried out, comparing the code predictions and the measured values of inside illuminance in the scale model. (author)

  11. Reactor building with internal structure of which the movements are independent of those of the general raft and process for building these internal structures

    International Nuclear Information System (INIS)

    Hista, J.C.

    1982-01-01

    This reactor building includes a containment enclosure for the internal structures composed of a slab wedged on its periphery against the containment enclosure gusset and resting on the general raft by means of a peripheral bearing ring, a compressible layer being provided between the general raft and the slab [fr

  12. SPOOL-FIRE: an IBM 370/195 code for the analysis of combined spray and pool burning of sodium

    International Nuclear Information System (INIS)

    Charak, I.; Person, L.W.

    1976-01-01

    A code for the computation of the pressure and temperatures within a containment building as a result of a sodium fire is described. The fire is assumed to occur in two distinct phases: a spray and a pool. The spray fire is conservatively assumed to occur instantaneously. The pool fire model used is the SOFIRE-II model developed by Atomics International. The code calculates all important temperatures, accounting for heat loss from the building to the environment, as well as leakage of the containment atmosphere under conditions of internal overpressure. The IBM CSMP methodology is used to solve the set of ordinary differential equations which model the system. The use of CSMP allows the user considerable flexibility in modifying the models employed

  13. Code for ethical international recruitment practices: the CGFNS alliance case study.

    Science.gov (United States)

    Shaffer, Franklin A; Bakhshi, Mukul; Dutka, Julia To; Phillips, Janice

    2016-06-30

    Projections indicate a global workforce shortage of approximately 4.3 million across the health professions. The need to ensure an adequate supply of health workers worldwide has created a context for the increased global migration of these professionals. The global trend in the migration of health professionals has given rise to the international recruitment industry to facilitate the passage of health workers from source to destination countries. This is particularly the case in the United States, where the majority of immigrant health professionals have come by way of the recruiting industry. This industry is largely unregulated in the United States as well as in many other countries, for which voluntary codes have been used as a means to increase transparency of the recruitment process, shape professional conduct, and mitigate harm to foreign-educated health workers. The CGFNS Alliance case study presented herein describes a multi-stakeholder effort in the United States to promote ethical recruitment practices. Such codes not only complement the WHO Global Code of Practice but are necessary to maximize the impact of these global standards on local settings. This case study offers both a historical perspective and a conceptual framework for examining the multiplicity of factors affecting the migration of human resources for health. The lessons learned provide critical insights into the factors pertaining to the relevancy and effectiveness of the WHO Code from the perspectives of both source and destination countries. This study provides a conceptual model for examining the usefulness of the WHO Code as well as how best to ensure its viability, sustainability, relevancy, and effectiveness in the global environment. This case study concludes with recommendations for evolving business models that need to be in place to strengthen the effectiveness of the WHO Code in the marketplace and to ensure its impact on the international recruitment industry in advancing

  14. Fire risk assessment method under the technical building code; Metodo de evaluacion del reisgo de incendio en el marco del Codigo Tecnico de la Edificacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Martin, J. C.; Diaz-Diaz, R.; Santos-Garcia, R.

    2010-07-01

    The high complexity of measuring and comparing the risk level of performance based design allowed by the Spain Building Code (CTE) and the lack of Spanish legislation on the matter makes a fire risk evaluation tool highly useful guiding the project's and the control authority over the feasibility of these complicated projects. A fire Risk Evaluation Method within the frame of the Spanish Building Code (MEREDICTE) has been developed trying to balance input sources, simplicity and clearness in its use. The number of parameters implied guarantees sound, exhaustive and reliable outputs. MEREDICTE is made of 73 parameters: 31 calculate potential risk and 42 obtain protection level. In an orientative way, MEREDICTE's parameters triple those of the most referred and extended evaluation method: the Gretener Method. The article shows the MEREDICTE technique and foundations, the methodology used in its investigation and development, its most significant innovation and its possible applications. Regarding the protection level, its formulation and applications re referred to the Windsor buildings of Madrid comparing the results obtained on the building as it was devastated by the fire of February 2005 and whether it fulfilled the Spanish building code conditions. (Author) 8 refs.

  15. Development of a definitive internal dosimetry code

    International Nuclear Information System (INIS)

    Miller, G.; Inkret, W.C.; Schillaci, M.E.

    1996-01-01

    Internal dosimetry may be divided into tow main problems: (1) the forward (scientific) problem of determining biokinetics models that describe how radionuclides are taken into the body, distributed in body tissues, and excreted, and (2) the inverse (mathematical) problem: given the measured amounts in excreta and assuming a biokinetic model, to determine the times and amounts of intakes into the body. The inverse problem of internal dosimetry is, in fact, a generic problem studied in other fields (e.g., image reconstruction, spectral deconvulution, and model parameter fitting). We have developed a code for plutonium internal dosimetry using the maximum entropy method, a method for solving underdetermined inverse problems with a positivity constraint. Within the framework of Bayesian statistics, we believe the definitive approach is to examine the Bayesian posterior probability describing the probability of an intake scenario (X i ) read ( ... ) as open-quotes the set of,close quotes where X i denotes the intake amount that occurs on the with day. For plutonium, for a worker with a long employment history, this is a very high dimensional probability space, since there may be on the order of 10,000 days when intakes may have occurred. Within this high dimensional space, we calculate the mean intake scenario as i > where denotes the expectation value over the posterior probability distribution. Similarly, we calculate uncertainties and other relevant quantities, such as X 2 , as expectation values over the posterior distribution. Thanks to a recent breakthrough in describing the mathematical structure of the intake process (a Poisson sum representation of intakes), we have developed the initial version of a Bayesian expectation-value algorithm for internal dosimetry reconstructions

  16. Building midwifery educator capacity using international partnerships: Findings from a qualitative study.

    Science.gov (United States)

    West, Florence; Dawson, Angela; Homer, Caroline S E

    2017-07-01

    Midwifery educators play a critical role in strengthening the midwifery workforce globally, including in low and lower-middle income countries (LMIC) to ensure that midwives are adequately prepared to deliver quality midwifery care. The most effective approach to building midwifery educator capacity is not always clear. The aim of this study was to determine how one capacity building approach in Papua New Guinea (PNG) used international partnerships to improve teaching and learning. A qualitative exploratory case study design was used to explore the perspectives of 26 midwifery educators working in midwifery education institutions in PNG. Seven themes were identified which provide insights into the factors that enable and constrain midwifery educator capacity building. The study provides insights into strategies which may aid institutions and individuals better plan and implement international midwifery partnerships to strengthen context-specific knowledge and skills in teaching. Further research is necessary to assess how these findings can be transferred to other contexts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Trust Management - Building Trust for International Cross Disciplinary Collaboration on Climate Change

    Science.gov (United States)

    Oakley, K. V.; Gurney, R. J.

    2014-12-01

    Successful communication and collaboration entails mutual understanding, and transfer, of information. The risk of misunderstanding and/or miscommunication between collaborating groups is tackled in different ways around the globe; some are well documented whereas others may be unknown outside particular groups, whether defined geographically or by specialism. For example; in some countries legally binding contracts define the terms of collaboration. Some regions place greater emphasis on developing trust relationships, and sometimes an official agreement is implied, such as many electronic data transfers on the web. International collaboration on climate change increasingly involves electronic data exchange (e.g. open access publications, shared documents, data repositories etc.) and with this increased reliance on electronic data a need has arisen for scientists to collaborate both internationally and cross-disciplinarily particularly with information technology and data management specialists. Trust of data and metadata on the internet (e.g. privacy, legitimacy etc.) varies, possibly due to a lack of internationally agreed standards for data governance and management, leaving many national, regional and institutional practices tailored to the needs of that group only. It is proposed that building trust relationships between cross-disciplinary and international groups could help facilitate further communication, understanding and benefits from the relationship, while still maintaining independence as separate groups. Complex international cross-disciplinary group relationship dynamics are not easily mapped and producing a set of trust building rules that can be applied to any current and future collaboration with equal validity may be unfeasible. An alternative to such a set of rules may be found in a Trust Manager, whose role is to improve mutually beneficial knowledge exchange between groups, build trust and increase future collaborative potential. This

  18. Building international collaborative capacity: contributions of community psychologists to a European network.

    Science.gov (United States)

    García-Ramírez, Manuel; Paloma, Virginia; Suarez-Balcazar, Yolanda; Balcazar, Fabricio

    2009-09-01

    Europe is in the process of building a more participative, just, and inclusive European Union. The European Social Fund, which is an initiative developed to actively promote multinational partnerships that address pressing social issues, is a good example of the European transformation. This article describes the steps taken to develop and evaluate the activities of an international network promoting collaborative capacity among regional partners involved in the prevention of labor discrimination toward immigrants in three European countries-Spain, Belgium, and Italy. An international team of community psychologists proposed an empowering approach to assess the collaborative capacity of the network. This approach consisted of three steps: (1) establishing a collaborative relationship among partners, (2) building collaborative capacity, and (3) evaluating the collaborative capacity of the network. We conclude with lessons learned from the process and provide recommendations for addressing the challenges inherent in international collaboration processes.

  19. Improving building energy efficiency in India: State-level analysis of building energy efficiency policies

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha; Tan, Qing; Evans, Meredydd; Kyle, Page; Vu, Linh; Patel, Pralit L.

    2017-11-01

    India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, building energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.

  20. Method for calculating internal radiation and ventilation with the ADINAT heat-flow code

    International Nuclear Information System (INIS)

    Butkovich, T.R.; Montan, D.N.

    1980-01-01

    One objective of the spent fuel test in Climax Stock granite (SFTC) is to correctly model the thermal transport, and the changes in the stress field and accompanying displacements from the application of the thermal loads. We have chosen the ADINA and ADINAT finite element codes to do these calculations. ADINAT is a heat transfer code compatible to the ADINA displacement and stress analysis code. The heat flow problem encountered at SFTC requires a code with conduction, radiation, and ventilation capabilities, which the present version of ADINAT does not have. We have devised a method for calculating internal radiation and ventilation with the ADINAT code. This method effectively reproduces the results from the TRUMP multi-dimensional finite difference code, which correctly models radiative heat transport between drift surfaces, conductive and convective thermal transport to and through air in the drifts, and mass flow of air in the drifts. The temperature histories for each node in the finite element mesh calculated with ADINAT using this method can be used directly in the ADINA thermal-mechanical calculation

  1. Roadmap for the Future of Commercial Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-01-01

    Building energy codes have significantly increased building efficiency over the last 38 years, since the first national energy code was published in 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. The current focus on prescriptive codes has limitations including significant variation in actual energy performance depending on which prescriptive options are chosen, a lack of flexibility for designers and developers, the inability to handle optimization that is specific to building type and use, the inability to account for project-specific energy costs, and the lack of follow-through or accountability after a certificate of occupancy is granted. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. This report provides a high-level review of different formats for commercial building energy codes, including prescriptive, prescriptive packages, capacity constrained, outcome based, and predictive performance approaches. This report also explores a next generation commercial energy code approach that places a greater emphasis on performance-based criteria.

  2. International piping benchmarks: use of the simplified code PACE 2. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J T; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom); ed.

    1979-05-15

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost.

  3. Final Technical Report for GO17004 Regulatory Logic: Codes and Standards for the Hydrogen Economy

    Energy Technology Data Exchange (ETDEWEB)

    Nakarado, Gary L. [Regulatory Logic LLC, Golden, CO (United States)

    2017-02-22

    The objectives of this project are to: develop a robust supporting research and development program to provide critical hydrogen behavior data and a detailed understanding of hydrogen combustion and safety across a range of scenarios, needed to establish setback distances in building codes and minimize the overall data gaps in code development; support and facilitate the completion of technical specifications by the International Organization for Standardization (ISO) for gaseous hydrogen refueling (TS 20012) and standards for on-board liquid (ISO 13985) and gaseous or gaseous blend (ISO 15869) hydrogen storage by 2007; support and facilitate the effort, led by the NFPA, to complete the draft Hydrogen Technologies Code (NFPA 2) by 2008; with experimental data and input from Technology Validation Program element activities, support and facilitate the completion of standards for bulk hydrogen storage (e.g., NFPA 55) by 2008; facilitate the adoption of the most recently available model codes (e.g., from the International Code Council [ICC]) in key regions; complete preliminary research and development on hydrogen release scenarios to support the establishment of setback distances in building codes and provide a sound basis for model code development and adoption; support and facilitate the development of Global Technical Regulations (GTRs) by 2010 for hydrogen vehicle systems under the United Nations Economic Commission for Europe, World Forum for Harmonization of Vehicle Regulations and Working Party on Pollution and Energy Program (ECE-WP29/GRPE); and to Support and facilitate the completion by 2012 of necessary codes and standards needed for the early commercialization and market entry of hydrogen energy technologies.

  4. International outage coding system for nuclear power plants. Results of a co-ordinated research project

    International Nuclear Information System (INIS)

    2004-05-01

    The experience obtained in each individual plant constitutes the most relevant source of information for improving its performance. However, experience of the level of the utility, country and worldwide is also extremely valuable, because there are limitations to what can be learned from in-house experience. But learning from the experience of others is admittedly difficult, if the information is not harmonized. Therefore, such systems should be standardized and applicable to all types of reactors satisfying the needs of the broad set of nuclear power plant operators worldwide and allowing experience to be shared internationally. To cope with the considerable amount of information gathered from nuclear power plants worldwide, it is necessary to codify the information facilitating the identification of causes of outages, systems or component failures. Therefore, the IAEA established a sponsored Co-ordinated Research Project (CRP) on the International Outage Coding System to develop a general, internationally applicable system of coding nuclear power plant outages, providing worldwide nuclear utilities with a standardized tool for reporting outage information. This TECDOC summarizes the results of this CRP and provides information for transformation of the historical outage data into the new coding system, taking into consideration the existing systems for coding nuclear power plant events (WANO, IAEA-IRS and IAEA PRIS) but avoiding duplication of efforts to the maximum possible extent

  5. The World Anti-Doping Code 2015: ASSER International Sports Law Blog symposium

    NARCIS (Netherlands)

    Duval, A.; Ram, H.; Viret, M.; Wisnosky, E.; Jacobs, H.L.; Morgan, M.

    This article brings together the contributions to a blog symposium on the new World Anti-Doping Code 2015 published on the ASSER International Sports Law Blog in October 2015. The contributions cover a variety of subjects, including the new sanctioning regime, the role of national anti-doping

  6. An Efficient Construction of Self-Dual Codes

    OpenAIRE

    Lee, Yoonjin; Kim, Jon-Lark

    2012-01-01

    We complete the building-up construction for self-dual codes by resolving the open cases over $GF(q)$ with $q \\equiv 3 \\pmod 4$, and over $\\Z_{p^m}$ and Galois rings $\\GR(p^m,r)$ with an odd prime $p$ satisfying $p \\equiv 3 \\pmod 4$ with $r$ odd. We also extend the building-up construction for self-dual codes to finite chain rings. Our building-up construction produces many new interesting self-dual codes. In particular, we construct 945 new extremal self-dual ternary $[32,16,9]$ codes, each ...

  7. Fire Risk Analysis and Optimization of Fire Prevention Management for Green Building Design and High Rise Buildings: Hong Kong Experience

    Directory of Open Access Journals (Sweden)

    Yau Albert

    2014-12-01

    Full Text Available There are many iconic high rise buildings in Hong Kong, for example, International Commercial Centre, International Financial Centre, etc. Fire safety issue in high rise buildings has been raised by local fire professionals in terms of occupant evacuation, means of fire-fighting by fire fighters, sprinkler systems to automatically put off fires in buildings, etc. Fire risk becomes an important issue in building fire safety because it relates to life safety of building occupants where they live and work in high rise buildings in Hong Kong. The aim of this research is to identify the fire risk for different types of high rise buildings in Hong Kong and to optimise the fire prevention management for those high rise buildings with higher level of fire risk and to validate the model and also to carry out the study of the conflict between the current fire safety building code and the current trend of green building design. Survey via the 7-point scale questionnaire was conducted through 50 participants and their responses were received and analysed via the statistical tool SPSS software computer program. A number of statistical methods of testing for significantly difference in samples were adopted to carry out the analysis of the data received. When the statistical analysis was completed, the results of the data analysis were validated by two Fire Safety Experts in this area of specialisation and also by quantitative fire risk analysis.

  8. Building International Business Theory: A Grounded Theory Approach

    OpenAIRE

    Gligor, David; Esmark, Carol; Golgeci, Ismail

    2016-01-01

    The field of international business (IB) is in need of more theory development (Morck & Yeung, 2007). As such, the main focus of our manuscript was to provide guidance on how to build IB specific theory using grounded theory (GT). Moreover, we contribute to future theory development by identifying areas within IB where GT can be applied and the type of research issues that can be addressed using this methodology. Finally, we make a noteworthy contribution by discussing some of GT’s caveats an...

  9. Women's Center Volunteer Intern Program: Building Community While Advancing Social and Gender Justice

    Science.gov (United States)

    Murray, Margaret A.; Vlasnik, Amber L.

    2015-01-01

    This program description explores the purpose, structure, activities, and outcomes of the volunteer intern program at the Wright State University Women's Center. Designed to create meaningful, hands-on learning experiences for students and to advance the center's mission, the volunteer intern program builds community while advancing social and…

  10. International Accreditation of ASME Codes and Standards

    International Nuclear Information System (INIS)

    Green, Mervin R.

    1989-01-01

    ASME established a Boiler Code Committee to develop rules for the design, fabrication and inspection of boilers. This year we recognize 75 years of that Code and will publish a history of that 75 years. The first Code and subsequent editions provided for a Code Symbol Stamp or mark which could be affixed by a manufacturer to a newly constructed product to certify that the manufacturer had designed, fabricated and had inspected it in accordance with Code requirements. The purpose of the ASME Mark is to identify those boilers that meet ASME Boiler and Pressure Vessel Code requirements. Through thousands of updates over the years, the Code has been revised to reflect technological advances and changing safety needs. Its scope has been broadened from boilers to include pressure vessels, nuclear components and systems. Proposed revisions to the Code are published for public review and comment four times per year and revisions and interpretations are published annually; it's a living and constantly evolving Code. You and your organizations are a vital part of the feedback system that keeps the Code alive. Because of this dynamic Code, we no longer have columns in newspapers listing boiler explosions. Nevertheless, it has been argued recently that ASME should go further in internationalizing its Code. Specifically, representatives of several countries, have suggested that ASME delegate to them responsibility for Code implementation within their national boundaries. The question is, thus, posed: Has the time come to franchise responsibility for administration of ASME's Code accreditation programs to foreign entities or, perhaps, 'institutes.' And if so, how should this be accomplished?

  11. Energy Code Enforcement Training Manual : Covering the Washington State Energy Code and the Ventilation and Indoor Air Quality Code.

    Energy Technology Data Exchange (ETDEWEB)

    Washington State Energy Code Program

    1992-05-01

    This manual is designed to provide building department personnel with specific inspection and plan review skills and information on provisions of the 1991 edition of the Washington State Energy Code (WSEC). It also provides information on provisions of the new stand-alone Ventilation and Indoor Air Quality (VIAQ) Code.The intent of the WSEC is to reduce the amount of energy used by requiring energy-efficient construction. Such conservation reduces energy requirements, and, as a result, reduces the use of finite resources, such as gas or oil. Lowering energy demand helps everyone by keeping electricity costs down. (It is less expensive to use existing electrical capacity efficiently than it is to develop new and additional capacity needed to heat or cool inefficient buildings.) The new VIAQ Code (effective July, 1991) is a natural companion to the energy code. Whether energy-efficient or not, an homes have potential indoor air quality problems. Studies have shown that indoor air is often more polluted than outdoor air. The VIAQ Code provides a means of exchanging stale air for fresh, without compromising energy savings, by setting standards for a controlled ventilation system. It also offers requirements meant to prevent indoor air pollution from building products or radon.

  12. Good collaborative practice: reforming capacity building governance of international health research partnerships.

    Science.gov (United States)

    Ward, Claire Leonie; Shaw, David; Sprumont, Dominique; Sankoh, Osman; Tanner, Marcel; Elger, Bernice

    2018-01-08

    In line with the policy objectives of the United Nations Sustainable Development Goals, this commentary seeks to examine the extent to which provisions of international health research guidance promote capacity building and equitable partnerships in global health research. Our evaluation finds that governance of collaborative research partnerships, and in particular capacity building, in resource-constrained settings is limited but has improved with the implementation guidance of the International Ethical Guidelines for Health-related Research Involving Humans by The Council for International Organizations of Medical Sciences (CIOMS) (2016). However, more clarity is needed in national legislation, industry and ethics guidelines, and regulatory provisions to address the structural inequities and power imbalances inherent in international health research partnerships. Most notably, ethical partnership governance is not supported by the principal industry ethics guidelines - the International Conference on Harmonization Technical Requirements for Registration of Pharmaceutical for Human Use (ICH) Good Clinical Practice (ICH-GCP). Given the strategic value of ICH-GCP guidelines in defining the role and responsibility of global health research partners, we conclude that such governance should stipulate the minimal requirements for creating an equitable environment of inclusion, mutual learning, transparency and accountability. Procedurally, this can be supported by i) shared research agenda setting with local leadership, ii) capacity assessments, and iii) construction of a memorandum of understanding (MoU). Moreover, the requirement of capacity building needs to be coordinated amongst partners to support good collaborative practice and deliver on the public health goals of the research enterprise; improving local conditions of health and reducing global health inequality. In this respect, and in order to develop consistency between sources of research governance, ICH

  13. Modules in historic building construction according to the Copenhagen Building Code

    DEFF Research Database (Denmark)

    Kudsk, Anders; Thuesen, Christian Langhoff; Hvam, Lars

    2011-01-01

    This paper describes an analysis of building works from Copenhagen, Denmark in the period 1850 to 1950. In the study we investigate, based on the theory of product architecture and product modularization, if examples of the use of well-defined interfaces can be found. Furthermore, the aim...... is to study how the use of such interfaces has influenced former building processes and how they were implemented and kept stable over decades. The result of the study is that at that time a number of standardized interfaces between the individual parts of the building work existed, and that these interfaces...

  14. Coding for dummies

    CERN Document Server

    Abraham, Nikhil

    2015-01-01

    Hands-on exercises help you learn to code like a pro No coding experience is required for Coding For Dummies,your one-stop guide to building a foundation of knowledge inwriting computer code for web, application, and softwaredevelopment. It doesn't matter if you've dabbled in coding or neverwritten a line of code, this book guides you through the basics.Using foundational web development languages like HTML, CSS, andJavaScript, it explains in plain English how coding works and whyit's needed. Online exercises developed by Codecademy, a leading online codetraining site, help hone coding skill

  15. A Bibliometric Review on Risk Management and Building Information Modeling for International Construction

    OpenAIRE

    Ganbat, Tsenguun; Chong, Heap-Yih; Liao, Pin-Chao; Wu, You-Di

    2018-01-01

    International construction is complicated and involves high risks. However, with the development of technological innovation, Building Information Modeling (BIM) emerged and seems to be able to address certain risks. To understand BIM applications in risk management for international construction, a state-of-the-art review is required. Therefore, this paper aims to identify the research trends and opportunities for risk management in BIM-enabled international construction by reviewing 526 pee...

  16. The Aster code; Code Aster

    Energy Technology Data Exchange (ETDEWEB)

    Delbecq, J.M

    1999-07-01

    The Aster code is a 2D or 3D finite-element calculation code for structures developed by the R and D direction of Electricite de France (EdF). This dossier presents a complete overview of the characteristics and uses of the Aster code: introduction of version 4; the context of Aster (organisation of the code development, versions, systems and interfaces, development tools, quality assurance, independent validation); static mechanics (linear thermo-elasticity, Euler buckling, cables, Zarka-Casier method); non-linear mechanics (materials behaviour, big deformations, specific loads, unloading and loss of load proportionality indicators, global algorithm, contact and friction); rupture mechanics (G energy restitution level, restitution level in thermo-elasto-plasticity, 3D local energy restitution level, KI and KII stress intensity factors, calculation of limit loads for structures), specific treatments (fatigue, rupture, wear, error estimation); meshes and models (mesh generation, modeling, loads and boundary conditions, links between different modeling processes, resolution of linear systems, display of results etc..); vibration mechanics (modal and harmonic analysis, dynamics with shocks, direct transient dynamics, seismic analysis and aleatory dynamics, non-linear dynamics, dynamical sub-structuring); fluid-structure interactions (internal acoustics, mass, rigidity and damping); linear and non-linear thermal analysis; steels and metal industry (structure transformations); coupled problems (internal chaining, internal thermo-hydro-mechanical coupling, chaining with other codes); products and services. (J.S.)

  17. Nonsteady heat conduction code with radiation boundary conditions

    International Nuclear Information System (INIS)

    Fillo, J.A.; Benenati, R.; Powell, J.

    1975-01-01

    A heat-transfer model for studying the temperature build-up in graphite blankets for fusion reactors is presented. In essence, the computer code developed is for two-dimensional, nonsteady heat conduction in heterogeneous, anisotropic solids with nonuniform internal heating. Thermal radiation as well as bremsstrahlung radiation boundary conditions are included. Numerical calculations are performed for two design options by varying the wall loading, bremsstrahlung, surface layer thickness and thermal conductivity, blanket dimensions, time step and grid size. (auth)

  18. The Apparel Industry and Codes of Conduct: A Solution to the International Child Labor Problem?

    Science.gov (United States)

    Bureau of International Labor Affairs (DOL), Washington, DC.

    Corporate codes of conduct prohibiting the use of child labor are becoming more common as consumers are increasingly calling upon companies to take responsibility for the conditions under which the goods they sell are manufactured. This report (the third volume in the Bureau of International Labor Affairs' international child labor series) details…

  19. Potential impacts of climate change on the built environment: ASHRAE climate zones, building codes and national energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Kumar, Jitendra [ORNL; Hoffman, Forrest M. [ORNL

    2017-10-01

    Statement of the Problem: ASHRAE releases updates to 90.1 “Energy Standard for Buildings except Low-Rise Residential Buildings” every three years resulting in a 3.7%-17.3% increase in energy efficiency for buildings with each release. This is adopted by or informs building codes in nations across the globe, is the National Standard for the US, and individual states elect which release year of the standard they will enforce. These codes are built upon Standard 169 “Climatic Data for Building Design Standards,” the latest 2017 release of which defines climate zones based on 8, 118 weather stations throughout the world and data from the past 8-25 years. This data may not be indicative of the weather that new buildings built today, will see during their upcoming 30-120 year lifespan. Methodology & Theoretical Orientation: Using more modern, high-resolution datasets from climate satellites, IPCC climate models (PCM and HadGCM), high performance computing resources (Titan) and new capabilities for clustering and optimization the authors briefly analyzed different methods for redefining climate zones. Using bottom-up analysis of multiple meteorological variables which were the subject matter, experts selected as being important to energy consumption, rather than the heating/cooling degree days currently used. Findings: We analyzed the accuracy of redefined climate zones, compared to current climate zones and how the climate zones moved under different climate change scenarios, and quantified the accuracy of these methods on a local level, at a national scale for the US. Conclusion & Significance: There is likely to be a significant annual, national energy and cost (billions USD) savings that could be realized by adjusting climate zones to take into account anticipated trends or scenarios in regional weather patterns.

  20. INTDOS: a computer code for estimating internal radiation dose using recommendations of the International Commission on Radiological Protection

    International Nuclear Information System (INIS)

    Ryan, M.T.

    1981-09-01

    INTDOS is a user-oriented computer code designed to calculate estimates of internal radiation dose commitment resulting from the acute inhalation intake of various radionuclides. It is designed so that users unfamiliar with the details of such can obtain results by answering a few questions regarding the exposure case. The user must identify the radionuclide name, solubility class, particle size, time since exposure, and the measured lung burden. INTDOS calculates the fractions of the lung burden remaining at time, t, postexposure considering the solubility class and particle size information. From the fraction remaining in the lung at time, t, the quantity inhaled is estimated. Radioactive decay is accounted for in the estimate. Finally, effective committed dose equivalents to various organs and tissues of the body are calculated using inhalation committed dose factors presented by the International Commission on Radiological Protection (ICRP). This computer code was written for execution on a Digital Equipment Corporation PDP-10 computer and is written in Fortran IV. A flow chart and example calculations are discussed in detail to aid the user who is unfamiliar with computer operations

  1. Search Results | Page 23 | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2010-04-23

    Results 221 - 230 of 875 ... The International Barcode of Life (iBOL) project, received a funding boost of $35 million from Canadian agencies for a 26-nation effort to collect specimens, sequence their DNA, and build an informatics platform using digital bar codes to store an. Published date. April 23, 2010. Journal articles.

  2. Building an International Financial Services Firm: How to design and execute cross-border strategies

    OpenAIRE

    Markus Venzin

    2009-01-01

    A new era of global banking and insurance is emerging, with leading banks eager to serve international markets. This book explores the issues that arise for banks in their strategic choices as they move into these new international markets. Building an International Financial Services Firm challenges conventional assumptions from the international management literature on topics such as the limits of globalization, the importance of cultural and institutional distance, the nature of economies...

  3. Participation in the international comparison of probabilistic consequence assessment codes organized by OECD/NEA and CEC. Final Report

    International Nuclear Information System (INIS)

    Rossi, J.

    1994-02-01

    Probabilistic Consequence Assessment (PCA) methods are exploited not only in risk evaluation but also to study alternative design features, reactor siting recommendations and to obtain acceptable dose criteria by the radiation safety authorities. The models are programmed into computer codes for these kind of assessment. To investigate the quality and competence of different models, OECD/NEA and CEC organized the international code comparison exercise, which was participated by the organizations from 15 countries. There were seven codes participating in the exercise. The objectives of the code comparison exercise were to compare the results by the codes, to contribute to PCA code quality assurance, to harmonize the codes, to provide a forum for discussion on various approaches and to produce the report on the exercise. The project started in 1991 and the results of the calculations were completed in autumn 1992. The international report consists of two parts: the Overview Report for decision makers and the supporting detailed Technical Report. The results of the project are reviewed as an user of the ARANO-programme of VTT and trends of it's further development are indicated in this report. (orig.) (11 refs., 13 figs., 4 tabs.)

  4. Catalytic allylic oxidation of internal alkenes to a multifunctional chiral building block

    Science.gov (United States)

    Bayeh, Liela; Le, Phong Q.; Tambar, Uttam K.

    2017-07-01

    The stereoselective oxidation of hydrocarbons is one of the most notable advances in synthetic chemistry over the past fifty years. Inspired by nature, enantioselective dihydroxylations, epoxidations and other oxidations of unsaturated hydrocarbons have been developed. More recently, the catalytic enantioselective allylic carbon-hydrogen oxidation of alkenes has streamlined the production of pharmaceuticals, natural products, fine chemicals and other functional materials. Allylic functionalization provides a direct path to chiral building blocks with a newly formed stereocentre from petrochemical feedstocks while preserving the olefin functionality as a handle for further chemical elaboration. Various metal-based catalysts have been discovered for the enantioselective allylic carbon-hydrogen oxidation of simple alkenes with cyclic or terminal double bonds. However, a general and selective allylic oxidation using the more common internal alkenes remains elusive. Here we report the enantioselective, regioselective and E/Z-selective allylic oxidation of unactivated internal alkenes via a catalytic hetero-ene reaction with a chalcogen-based oxidant. Our method enables non-symmetric internal alkenes to be selectively converted into allylic functionalized products with high stereoselectivity and regioselectivity. Stereospecific transformations of the resulting multifunctional chiral building blocks highlight the potential for rapidly converting internal alkenes into a broad range of enantioenriched structures that can be used in the synthesis of complex target molecules.

  5. Compliance Behavior Analysis of the Ship Crew to the International Safety Management (Ism) Code in Indonesia???

    OpenAIRE

    Desi Albert Mamahit; Heny K Daryanto; Ujang Sumarwan; Eva Zhoriva Yusuf

    2013-01-01

    The purpose of this code is to provide international standards for the management and safe operation of ships and pollution prevention Furthermore, this study has the objective to identify the role of the ISM Code on maritime activities in Indonesia, knowing the perceptions and attitudes regarding the conduct of the crew boat ISM Code. Location research is conducted on the crew that was in the Port of Tanjung Priok in Jakarta. Data collection and processing is done for 3 months. The study was...

  6. Protecting breastfeeding in West and Central Africa: over 25 years of implementation of the International Code of Marketing of Breastmilk Substitutes.

    Science.gov (United States)

    Sokol, Ellen; Clark, David; Aguayo, Victor M

    2008-09-01

    In 1981 the World Health Assembly (WHA) adopted the International Code of Marketing of Breastmilk Substitutes out of concern that inappropriate marketing of breastmilk substitutes was contributing to the alarming decline in breastfeeding worldwide and the increase in child malnutrition and mortality, particularly in developing countries. To document progress, challenges, and lessons learned in the implementation of the International Code in West and Central Africa. Data were obtained by literature review and interviews with key informants. Twelve of the 24 countries have laws, decrees, or regulations that implement all or most of the provisions of the Code, 6 countries have a draft law or decree that is awaiting government approval or have a government committee that is studying how best to implement the Code, 3 countries have a legal instrument that enacts a few provisions of the Code, and 3 countries have not taken any action to implement the Code. International declarations and initiatives for child nutrition and survival have provided impetus for national implementation of the Code. National action to regulate the marketing of breastmilk substitutes needs to be linked to national priorities for nutrition and child survival. A clearly defined scope is essential for effective implementation of national legislation. Leadership and support by health professionals is essential to endorse and enforce national legislation. Training on Code implementation is instrumental for national action; national implementation of the Code requires provisions and capacity to monitor and enforce the legislative framework and needs to be part of a multipronged strategy to advance national child nutrition and survival goals. Nations in West and Central Africa have made important progress in implementing the International Code. More than 25 years after its adoption by the WHA, the Code remains as important as ever for child survival and development in West and Central Africa.

  7. Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian; Athalye, Rahul A.; Hart, Philip R.; Rosenberg, Michael I.; Xie, YuLong; Goel, Supriya; Mendon, Vrushali V.; Liu, Bing

    2013-08-30

    The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

  8. Code of conduct for scientists (abstract)

    International Nuclear Information System (INIS)

    Khurshid, S.J.

    2011-01-01

    The emergence of advanced technologies in the last three decades and extraordinary progress in our knowledge on the basic Physical, Chemical and Biological properties of living matter has offered tremendous benefits to human beings but simultaneously highlighted the need of higher awareness and responsibility by the scientists of 21 century. Scientist is not born with ethics, nor science is ethically neutral, but there are ethical dimensions to scientific work. There is need to evolve an appropriate Code of Conduct for scientist particularly working in every field of Science. However, while considering the contents, promulgation and adaptation of Codes of Conduct for Scientists, a balance is needed to be maintained between freedom of scientists and at the same time some binding on them in the form of Code of Conducts. The use of good and safe laboratory procedures, whether, codified by law or by common practice must also be considered as part of the moral duties of scientists. It is internationally agreed that a general Code of Conduct can't be formulated for all the scientists universally, but there should be a set of 'building blocks' aimed at establishing the Code of Conduct for Scientists either as individual researcher or responsible for direction, evaluation, monitoring of scientific activities at the institutional or organizational level. (author)

  9. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Illinois Jurisdictions

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.; Cort, Katherine A.; Winiarski, David W.; Richman, Eric E.; Friedrich, Michele

    2002-05-01

    ASHRAE Standard 90.1-1999 was developed in an effort to set minimum requirements for energy efficienty design and construction of new commercial buildings. This report assesses the benefits and costs of adopting this standard as the building energy code in Illinois. Energy and economic impacts are estimated using BLAST combined with a Life-Cycle Cost approach to assess corresponding economic costs and benefits.

  10. International pressure vessels and piping codes and standards. Volume 2: Current perspectives; PVP-Volume 313-2

    International Nuclear Information System (INIS)

    Rao, K.R.; Asada, Yasuhide; Adams, T.M.

    1995-01-01

    The topics in this volume include: (1) Recent or imminent changes to Section 3 design sections; (2) Select perspectives of ASME Codes -- Section 3; (3) Select perspectives of Boiler and Pressure Vessel Codes -- an international outlook; (4) Select perspectives of Boiler and Pressure Vessel Codes -- ASME Code Sections 3, 8 and 11; (5) Codes and Standards Perspectives for Analysis; (6) Selected design perspectives on flow-accelerated corrosion and pressure vessel design and qualification; (7) Select Codes and Standards perspectives for design and operability; (8) Codes and Standards perspectives for operability; (9) What's new in the ASME Boiler and Pressure Vessel Code?; (10) A look at ongoing activities of ASME Sections 2 and 3; (11) A look at current activities of ASME Section 11; (12) A look at current activities of ASME Codes and Standards; (13) Simplified design methodology and design allowable stresses -- 1 and 2; (14) Introduction to Power Boilers, Section 1 of the ASME Code -- Part 1 and 2. Separate abstracts were prepared for most of the individual papers

  11. Lighting energy efficiency in office buildings: Sri Lanka

    International Nuclear Information System (INIS)

    Wijayatunga, Priyantha D.C.; Fernando, W.J.L.S.; Ranasinghe, S.

    2003-01-01

    This paper describes a study conducted in the lighting sector of office buildings as a part of a broader research study aimed at developing building codes for Sri Lanka addressing lighting as well as thermal comfort in order to optimise the use of electricity within these buildings. The study covered different tasks performed in office buildings and the optimum lighting levels required to perform these tasks in the office environment in Sri Lanka. Also, it included assessing the visual performance of people involved in different activities under varying illumination levels in a controlled environment and a comparison of these optimum lighting levels with international standards. It can be seen that the required optimum lighting levels are generally lower in Sri Lanka in comparison to specified standard levels, and this scenario is likely to be similar in other developing countries too. These findings clearly emphasise the need to adopt lighting standards most appropriate to local conditions, in turn helping improve the energy efficiency within buildings

  12. Green Building Tools for Tribes

    Science.gov (United States)

    Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.

  13. Improving energy performance of school buildings while ensuring indoor air quality ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Rachel; Goldberger, Itamar [Technion - Israel Institute of Technology, Haifa (Israel). Faculty of Civil and Environmental Engineering, Department of Structural Engineering and Construction Management; Paciuk, Monica [National Building Research Institute, Technion, Haifa (Israel)

    2007-09-15

    Energy conscious design of school buildings, as well as deemed-to-satisfy provisions in a Performance Based Energy Code, should address the problem known as the energy efficiency - thermal comfort - indoor air quality dilemma (EE-TC-IAQ Dilemma). In warm and moderate climates, the large internal heat sources usually found in school buildings prevent achieving thermal comfort without active cooling in summer, but are not sufficient to eliminate the need for heating in winter. Commonly used air-conditioners do not improve air quality, while natural ventilation induces uncontrolled energy losses. In this study, a step by step process was used for the development of deemed-to-satisfy design solutions, which cope with the EE-TC-IAQ Dilemma, for a performance based code. A distinction is made between improving building design variables and improving ventilation schemes. Results indicate that implementation of improved ventilation schemes in an otherwise well designed energy-conscious building result in savings of 28-30% and 17-18% for northern and southern classroom orientations, respectively. (author)

  14. Tribal Green Building Toolkit

    Science.gov (United States)

    This Tribal Green Building Toolkit (Toolkit) is designed to help tribal officials, community members, planners, developers, and architects develop and adopt building codes to support green building practices. Anyone can use this toolkit!

  15. Infinity-Norm Permutation Covering Codes from Cyclic Groups

    OpenAIRE

    Karni, Ronen; Schwartz, Moshe

    2017-01-01

    We study covering codes of permutations with the $\\ell_\\infty$-metric. We provide a general code construction, which uses smaller building-block codes. We study cyclic transitive groups as building blocks, determining their exact covering radius, and showing linear-time algorithms for finding a covering codeword. We also bound the covering radius of relabeled cyclic transitive groups under conjugation.

  16. Feedback Codes and Action Plans: Building the Capacity of First-Year Students to Apply Feedback to a Scientific Report

    Science.gov (United States)

    Bird, Fiona L.; Yucel, Robyn

    2015-01-01

    Effective feedback can build self-assessment skills in students so that they become more competent and confident to identify and self-correct weaknesses in their work. In this study, we trialled a feedback code as part of an integrated programme of formative and summative assessment tasks, which provided feedback to first-year students on their…

  17. Green Building Standards

    Science.gov (United States)

    Many organizations have developed model codes or rating systems that communities may use to develop green building programs or revise building ordinances. Some of the major options are listed on this page.

  18. GASFLOW: the theoretical model to analyze accidents in nuclear containments, confinements, and facility buildings

    International Nuclear Information System (INIS)

    Travis, J.R.; Wilson, T.L.

    1993-01-01

    This report documents the governing physical equations for GASFLOW, a finite-volume computer code for solving transient, three-dimensional, compressible, Navier-Stokes equations for multiple gas species. The code is designed to be a best-estimate tool for predicting the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containments, confinements, and other facility buildings. An analysis with GASFLOW will result in time-dependent gas species concentrations throughout the structure analyzed, and in the event of combustion the pressure and temperature loadings on the walls and internal structures. GASFLOW can model geometrically complex containment systems with multiple compartments and internal structures. It can calculate gas behavior of low-speed buoyancy-driven flows, of diffusion-dominated flows, and during deflagrations. The code can model condensation heat transfer to walls and internal structures by natural and forced convection; chemical kinetics of combustion of hydrogen or hydrocarbon fuels; and fluid turbulence. Heat conduction within walls and structures is considered one-dimensional. 17 refs., 1 fig., 1 tab

  19. Building an "International Code for Public Education": Behind the Scenes at the International Bureau of Education (1925-1946)

    Science.gov (United States)

    Hofstetter, Rita

    2015-01-01

    The founders of the International Bureau of Education (IBE) in Geneva were convinced the best way to develop understanding between peoples was by disseminating knowledge: collecting pedagogical materials from around the world, making them accessible to all, and enriching them through collective studies and conferences where attendees could engage…

  20. Second International Workshop on Software Engineering and Code Design in Parallel Meteorological and Oceanographic Applications

    Science.gov (United States)

    OKeefe, Matthew (Editor); Kerr, Christopher L. (Editor)

    1998-01-01

    This report contains the abstracts and technical papers from the Second International Workshop on Software Engineering and Code Design in Parallel Meteorological and Oceanographic Applications, held June 15-18, 1998, in Scottsdale, Arizona. The purpose of the workshop is to bring together software developers in meteorology and oceanography to discuss software engineering and code design issues for parallel architectures, including Massively Parallel Processors (MPP's), Parallel Vector Processors (PVP's), Symmetric Multi-Processors (SMP's), Distributed Shared Memory (DSM) multi-processors, and clusters. Issues to be discussed include: (1) code architectures for current parallel models, including basic data structures, storage allocation, variable naming conventions, coding rules and styles, i/o and pre/post-processing of data; (2) designing modular code; (3) load balancing and domain decomposition; (4) techniques that exploit parallelism efficiently yet hide the machine-related details from the programmer; (5) tools for making the programmer more productive; and (6) the proliferation of programming models (F--, OpenMP, MPI, and HPF).

  1. Use of MCAM in creating 3D neutronics model for ITER building

    International Nuclear Information System (INIS)

    Zeng Qin; Wang Guozhong; Dang Tongqiang; Long Pengcheng; Loughlin, Michael

    2012-01-01

    Highlights: ► We created a 3D neutronics model of the ITER building. ► The model was produced from the engineering CAD model by MCAM software. ► The neutron flux map in the ITER building was calculated. - Abstract: The three dimensional (3D) neutronics reference model of International Thermonuclear Experimental Reactor (ITER) only defines the tokamak machine and extends to the bio-shield. In order to meet further 3D neutronics analysis needs, it is necessary to create a 3D reference model of the ITER building. Monte Carlo Automatic Modeling Program for Radiation Transport Simulation (MCAM) was developed as a computer aided design (CAD) based bi-directional interface program between general CAD systems and Monte Carlo radiation transport simulation codes. With the help of MCAM version 4.8, the 3D neutronics model of ITER building was created based on the engineering CAD model. The calculation of the neutron flux map in ITER building during operation showed the correctness and usability of the model. This model is the first detailed ITER building 3D neutronics model and it will be made available to all international organization collaborators as a reference model.

  2. Building a "National Civilization" at Home and Abroad: International Students and Changing U.S. Political Economy

    Science.gov (United States)

    Aw, Fanta

    2011-01-01

    The research study examines the relationship of international students to changing U.S. political economy. The research attempts to move international students from the periphery to the center of understanding the changing U.S. political economy in the twenty-first century. I argue that international students play an important role in building a…

  3. Comparison of european computer codes relative to the aerosol behavior in PWR containment buildings during severe core damage accidents

    International Nuclear Information System (INIS)

    Fermandjian, J.; Beonio-Brocchieri, F.

    1986-09-01

    The present study concerns a comparative exercise, performed within the framework of the Commission of the European Communities, of the computer codes used in reactor safety in order to assess their capability of realistically describing the aerosol behavior in PWR reactor containment buildings during severe accidents. The codes included in the present study are the following: AEROSIM-M, AEROSOLS/Bl, CORRAL-2, NAUA Mod5. In AEROSIM-M, AEROSOLS/Bl and NAUA Mod5, the integro-differential equation for the evolution of the particle mass distribution is approximated by a set of coupled first order differential equations. To this end, the particle distribution function is replaced by a number of discrete monodisperse fractions. The CORRAL-2 has an essentially empirical basis (processes not explicitely modelled, but their net effects accounted for). The physical processes taken into account in the codes are shown finally

  4. Confidence building on the total system performance assessment code, MASCOT-K for permanent disposal of HLW in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Y. S.; Kim, S. G.; Kang, C. H

    2002-12-01

    To perform Total System Performance Assessment(TSPA) of a potential HLW repository, it is necessary to develop the TSPA code. KAERI has developed the one-dimensional PSA code MASCOT-K since 1997 and verified special modules dedicated for the dissolution of spent nuclear fuel. In the second R and D phase, MASCOT-K is once again verified as a part of the confidence building for TSPA. The AMBER code based on the totally different mathematical approach, compartment theory is used together with MASCOT-K to assess the annual individual doses for given K- and Q- scenarios. Results indicate that both AMBER and MASCOT-K simulate the annual individual doses to a potential biosphere. And the MASCOT-K is more flexible to describe the natural barrier such as a fracture for sensitivity studies. In the third R and D phase, MASCOT-K will be actively used to check whether the proposed KAERI reference disposal concept is solid or not.

  5. Confidence building on the total system performance assessment code, MASCOT-K for permanent disposal of HLW in Korea

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Kim, S. G.; Kang, C. H.

    2002-12-01

    To perform Total System Performance Assessment(TSPA) of a potential HLW repository, it is necessary to develop the TSPA code. KAERI has developed the one-dimensional PSA code MASCOT-K since 1997 and verified special modules dedicated for the dissolution of spent nuclear fuel. In the second R and D phase, MASCOT-K is once again verified as a part of the confidence building for TSPA. The AMBER code based on the totally different mathematical approach, compartment theory is used together with MASCOT-K to assess the annual individual doses for given K- and Q- scenarios. Results indicate that both AMBER and MASCOT-K simulate the annual individual doses to a potential biosphere. And the MASCOT-K is more flexible to describe the natural barrier such as a fracture for sensitivity studies. In the third R and D phase, MASCOT-K will be actively used to check whether the proposed KAERI reference disposal concept is solid or not

  6. Sensibility analysis of fuel depletion using different nuclear fuel depletion codes

    Energy Technology Data Exchange (ETDEWEB)

    Martins, F.; Velasquez, C.E.; Castro, V.F.; Pereira, C.; Silva, C. A. Mello da, E-mail: felipmartins94@gmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: victorfariascastro@gmail.com, E-mail: claubia@nuclear.ufmg.br, E-mail: clarysson@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Nowadays, the utilization of different nuclear codes to perform the depletion and criticality calculations has been used to simulated nuclear reactors problems. Therefore, the goal is to analyze the sensibility of the fuel depletion of a PWR assembly using three different nuclear fuel depletion codes. The burnup calculations are performed using the codes MCNP5/ORIGEN2.1 (MONTEBURNS), KENO-VI/ORIGEN-S (TRITONSCALE6.0) and MCNPX (MCNPX/CINDER90). Each nuclear code performs the burnup using different depletion codes. Each depletion code works with collapsed energies from a master library in 1, 3 and 63 groups, respectively. Besides, each code uses different ways to obtain neutron flux that influences the depletions calculation. The results present a comparison of the neutronic parameters and isotopes composition such as criticality and nuclides build-up, the deviation in results are going to be assigned to features of the depletion code in use, such as the different radioactive decay internal libraries and the numerical method involved in solving the coupled differential depletion equations. It is also seen that the longer the period is and the more time steps are chosen, the larger the deviation become. (author)

  7. Sensibility analysis of fuel depletion using different nuclear fuel depletion codes

    International Nuclear Information System (INIS)

    Martins, F.; Velasquez, C.E.; Castro, V.F.; Pereira, C.; Silva, C. A. Mello da

    2017-01-01

    Nowadays, the utilization of different nuclear codes to perform the depletion and criticality calculations has been used to simulated nuclear reactors problems. Therefore, the goal is to analyze the sensibility of the fuel depletion of a PWR assembly using three different nuclear fuel depletion codes. The burnup calculations are performed using the codes MCNP5/ORIGEN2.1 (MONTEBURNS), KENO-VI/ORIGEN-S (TRITONSCALE6.0) and MCNPX (MCNPX/CINDER90). Each nuclear code performs the burnup using different depletion codes. Each depletion code works with collapsed energies from a master library in 1, 3 and 63 groups, respectively. Besides, each code uses different ways to obtain neutron flux that influences the depletions calculation. The results present a comparison of the neutronic parameters and isotopes composition such as criticality and nuclides build-up, the deviation in results are going to be assigned to features of the depletion code in use, such as the different radioactive decay internal libraries and the numerical method involved in solving the coupled differential depletion equations. It is also seen that the longer the period is and the more time steps are chosen, the larger the deviation become. (author)

  8. Comparison of computer codes relative to the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

    International Nuclear Information System (INIS)

    Fermandjian, J.; Bunz, H.; Dunbar, I.; Gauvain, J.; Ricchena, R.

    1986-01-01

    The present study concerns a comparative exercise, performed within the framework of the Commission of the European Communities, of the computer codes (AEROSIM-M, UK; AEROSOLS/B1, France; CORRAL-2, CEC and NAUA Mod5, Germany) used in order to assess the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR. Topics considered in this paper include aerosols, containment buildings, reactor safety, fission product release, reactor cores, meltdown, and monitoring

  9. Building an International Geosciences Network (i-GEON) for cyberinfrastructure-based Research and Education

    Science.gov (United States)

    Seber, D.; Baru, C.

    2007-05-01

    The Geosciences Network (GEON) project is a collaboration among multiple institutions to develop a cyberinfrastructure (CI) platform in support of integrative geoscience research activities. Taking advantage of the state-of-the-art information technology resources GEON researchers are building a cyberinfrastructure designed to enable data sharing, resource discovery, semantic data integration, high-end computations and 4D visualization in an easy-to-use web-based environment. The cyberinfrastructure in GEON is required to support an inherently distributed system, since the scientists, who are users as well as providers of resources, are themselves distributed. International collaborations are a natural extension of GEON; the geoscience research requires strong international collaborations. The goals of the i-GEON activities are to collaborate with international partners and jointly build a cyberinfrastructure for the geosciences to enable collaborative work environments. International partners can participate in GEON efforts, establish GEON nodes at their universities, institutes, or agencies and also contribute data and tools to the network. Via jointly run cyberinfrastructure workshops, the GEON team also introduces students, scientists, and research professionals to the concepts of IT-based geoscience research and education. Currently, joint activities are underway with the Chinese Academy of Sciences in China, the GEO Grid project at AIST in Japan, and the University of Hyderabad in India (where the activity is funded by the Indo-US Science and Technology Forum). Several other potential international partnerships are under consideration. iGEON is open to all international partners who are interested in working towards the goal of data sharing, managing and integration via IT-based platforms. Information about GEON and its international activities can be found at http:www.geongrid.org/

  10. Towards sustainable public FM: collective building of capabilities

    DEFF Research Database (Denmark)

    Ramskov Galamba, Kirsten; Nielsen, Susanne Balslev

    2016-01-01

    Purpose Public facilities management (FM) is in the unique position of aligning building projects and FM with the policies of sustainable development at societal level. However, sustainable facilities management (SFM) is an emergent profession, and there is a need to build a code of conduct for SFM...... in FM organisations. The purpose is to develop and test a workshop based concept for collective building of capabilities targeting in-house FM organisations, in particular public in-house FM organisations. Design/methodology/approach This research explores the role of public facilities managers...... and examines how an empowerment process can help FM employees develop collective competences for SFM. The methodologies used are literature review, and a 3–year-long action research process in the Danish local authority, Albertslund, which is internationally recognised for its innovative and green profile...

  11. Modelling of internal structure in seismic analysis of a PHWR building

    International Nuclear Information System (INIS)

    Reddy, G.R.; Vaze, K.K.; Kushawaha, H.S.; Ingle, R.K.; Subramanian, K.V.

    1991-01-01

    Seismic analysis of complex and large structures, consisting of thick shear walls, such as Reactor Building is very involved and time consuming. It is a standard practice to model the structure as a stick model to predict reasonably the dynamic behaviour of the structure. It is required to determine approximate equivalent sectional properties of Internal Structure for representation in the stick model. The restraint to warping can change the stress distribution thus affecting the centre of rigidity and torsional inertia, Hence, standard formulae does not hold good for determination of sectional properties of the Internal Structure. In this case the equivalent sectional properties for the Internal Structure are calculated using a Finite Element Model (FEM) of the Internal Structure and applying unit horizontal forces in each direction. A 3-D stick model is developed using the guidelines. Using the properties calculated by FEM and also by standard formulae, the responses of the 3-D stick model are compared. (J.P.N.)

  12. Design and operation of ventilation in low energy residences – A survey on code requirements and building reality from six European countries and China

    DEFF Research Database (Denmark)

    del Carmen Bocanegra-Yanez, Maria; Rojas, Gabriel; Zukowska-Tejsen, Daria

    involved in the Annex. There were two main objectives, firstly, to describe and analyse a transition between actual requirements (national building codes and standards) and current practice. Secondly, to investigate current barriers and challenges regarding installation of mechanical ventilation......One of the key objectives of the IEA Annex 68 research programme entitled “Indoor Air Quality Design and Control in Low Energy Residential Buildings” is to provide a generic guideline for the design and operation of ventilation in residential buildings. Modern and refurnished domestic buildings...

  13. Life Cycle Cost Optimization of a BOLIG+ Zero Energy Building

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna

    . However, before being fully implemented in the national building codes and international standards, the ZEB concept requires a clear understanding and a uniform definition. The ZEB concept is an energy-conservation solution, whose successful adaptation in real life depends significantly on private...... building owners’ approach to it. For this particular target group, the cost is often an obstacle when investing money in environmental or climate friendly products. Therefore, this PhD project took the perspective of a future private ZEB owner to investigate the cost-optimal Net ZEB definition applicable...... in the Danish context. The review of the various ZEB approaches indicated a general concept of a Zero Energy Building as a building with significantly reduced energy demand that is balanced by an equivalent energy generation from renewable sources. And, with this as a general framework, each ZEB definition...

  14. New Site Coefficients and Site Classification System Used in Recent Building Seismic Code Provisions

    Science.gov (United States)

    Dobry, R.; Borcherdt, R.D.; Crouse, C.B.; Idriss, I.M.; Joyner, W.B.; Martin, G.R.; Power, M.S.; Rinne, E.E.; Seed, R.B.

    2000-01-01

    Recent code provisions for buildings and other structures (1994 and 1997 NEHRP Provisions, 1997 UBC) have adopted new site amplification factors and a new procedure for site classification. Two amplitude-dependent site amplification factors are specified: Fa for short periods and Fv for longer periods. Previous codes included only a long period factor S and did not provide for a short period amplification factor. The new site classification system is based on definitions of five site classes in terms of a representative average shear wave velocity to a depth of 30 m (V?? s). This definition permits sites to be classified unambiguously. When the shear wave velocity is not available, other soil properties such as standard penetration resistance or undrained shear strength can be used. The new site classes denoted by letters A - E, replace site classes in previous codes denoted by S1 - S4. Site classes A and B correspond to hard rock and rock, Site Class C corresponds to soft rock and very stiff / very dense soil, and Site Classes D and E correspond to stiff soil and soft soil. A sixth site class, F, is defined for soils requiring site-specific evaluations. Both Fa and Fv are functions of the site class, and also of the level of seismic hazard on rock, defined by parameters such as Aa and Av (1994 NEHRP Provisions), Ss and S1 (1997 NEHRP Provisions) or Z (1997 UBC). The values of Fa and Fv decrease as the seismic hazard on rock increases due to soil nonlinearity. The greatest impact of the new factors Fa and Fv as compared with the old S factors occurs in areas of low-to-medium seismic hazard. This paper summarizes the new site provisions, explains the basis for them, and discusses ongoing studies of site amplification in recent earthquakes that may influence future code developments.

  15. International integral experiments databases in support of nuclear data and code validation

    International Nuclear Information System (INIS)

    Briggs, J. Blair; Gado, Janos; Hunter, Hamilton; Kodeli, Ivan; Salvatores, Massimo; Sartori, Enrico

    2002-01-01

    The OECD/NEA Nuclear Science Committee (NSC) has identified the need to establish international databases containing all the important experiments that are available for sharing among the specialists. The NSC has set up or sponsored specific activities to achieve this. The aim is to preserve them in an agreed standard format in computer accessible form, to use them for international activities involving validation of current and new calculational schemes including computer codes and nuclear data libraries, for assessing uncertainties, confidence bounds and safety margins, and to record measurement methods and techniques. The databases so far established or in preparation related to nuclear data validation cover the following areas: SINBAD - A Radiation Shielding Experiments database encompassing reactor shielding, fusion blanket neutronics, and accelerator shielding. ICSBEP - International Criticality Safety Benchmark Experiments Project Handbook, with more than 2500 critical configurations with different combination of materials and spectral indices. IRPhEP - International Reactor Physics Experimental Benchmarks Evaluation Project. The different projects are described in the following including results achieved, work in progress and planned. (author)

  16. A self-organized internal models architecture for coding sensory-motor schemes

    Directory of Open Access Journals (Sweden)

    Esaú eEscobar Juárez

    2016-04-01

    Full Text Available Cognitive robotics research draws inspiration from theories and models on cognition, as conceived by neuroscience or cognitive psychology, to investigate biologically plausible computational models in artificial agents. In this field, the theoretical framework of Grounded Cognition provides epistemological and methodological grounds for the computational modeling of cognition. It has been stressed in the literature that textit{simulation}, textit{prediction}, and textit{multi-modal integration} are key aspects of cognition and that computational architectures capable of putting them into play in a biologically plausible way are a necessity.Research in this direction has brought extensive empirical evidencesuggesting that textit{Internal Models} are suitable mechanisms forsensory-motor integration. However, current Internal Models architectures show several drawbacks, mainly due to the lack of a unified substrate allowing for a true sensory-motor integration space, enabling flexible and scalable ways to model cognition under the embodiment hypothesis constraints.We propose the Self-Organized Internal ModelsArchitecture (SOIMA, a computational cognitive architecture coded by means of a network of self-organized maps, implementing coupled internal models that allow modeling multi-modal sensory-motor schemes. Our approach addresses integrally the issues of current implementations of Internal Models.We discuss the design and features of the architecture, and provide empirical results on a humanoid robot that demonstrate the benefits and potentialities of the SOIMA concept for studying cognition in artificial agents.

  17. Enforcing the International Code of Marketing of Breast-milk Substitutes for Better Promotion of Exclusive Breastfeeding: Can Lessons Be Learned?

    Science.gov (United States)

    Barennes, Hubert; Slesak, Guenther; Goyet, Sophie; Aaron, Percy; Srour, Leila M

    2016-02-01

    Exclusive breastfeeding, one of the best natural resources, needs protection and promotion. The International Code of Marketing of Breast-milk Substitutes (the Code), which aims to prevent the undermining of breastfeeding by formula advertising, faces implementation challenges. We reviewed frequently overlooked challenges and obstacles that the Code is facing worldwide, but particularly in Southeast Asia. Drawing lessons from various countries where we work, and following the example of successful public health interventions, we discussed legislation, enforcement, and experiences that are needed to successfully implement the Code. Successful holistic approaches that have strengthened the Code need to be scaled up. Community-based actions and peer-to-peer promotions have proved successful. Legislation without stringent enforcement and sufficient penalties is ineffective. The public needs education about the benefits and ways and means to support breastfeeding. It is crucial to combine strong political commitment and leadership with strict national regulations, definitions, and enforcement. National breastfeeding committees, with the authority to improve regulations, investigate violations, and enforce the laws, must be established. Systematic monitoring and reporting are needed to identify companies, individuals, intermediaries, and practices that infringe on the Code. Penalizing violators is crucial. Managers of multinational companies must be held accountable for international violations, and international legislative enforcement needs to be established. Further measures should include improved regulations to protect the breastfeeding mother: large-scale education campaigns; strong penalties for Code violators; exclusion of the formula industry from nutrition, education, and policy roles; supportive legal networks; and independent research of interventions supporting breastfeeding. © The Author(s) 2015.

  18. Global building physics

    DEFF Research Database (Denmark)

    Rode, Carsten

    2013-01-01

    High ambitions are set for the building physics performance of buildings today. No single technology can achieve fulfilment of these ambitions alone. Integrated, multi-facetted solutions and optimization are necessary. A holistic, or ‘global’, technological perspective is needed, which includes all...... aspects of the building as defined in building engineering. We live in an international society and building solutions are developed across country borders. Building physics is a global theme. The International Association of Building Physics has global appeal. This brief article reports the keynote...

  19. Global Building Physics

    DEFF Research Database (Denmark)

    Rode, Carsten

    2012-01-01

    High ambitions are set for the building physics performance of buildings today. No single technology can achieve fulfilment of these ambitions alone. Integrated, multi-facetted solutions and optimization are necessary. A holistic, or “global”, technological perspective is needed, which includes all...... aspects of the building as defined in building engineering. We live in an international society and building solutions are developed across country borders. Building physics is a global theme. The International Association of Building Physics has global appeal. The keynote lecture and this brief paper...

  20. Energy - efficient buildings in pakistan

    International Nuclear Information System (INIS)

    Sohail, M.; Qureshi, M.U.D.

    2011-01-01

    Pakistan is one of the countries with the highest energy consumption for domestic use. Annual energy consumption by the domestic sector is 45.9 % of the total, while the industrial sector, consumes about 27.5%. About half of the total energy consumed is used in buildings and/or heating, ventilation and air-conditioning (HVAC) and lighting appliances. The energy consumed for the same purposes in China and UK is 25 to 30 % and 40 %, respectively, even in extreme weather conditions. Energy deficiency in Pakistan is approximately 5,000 MWe, which results in worst load-shedding in summers and, lately, even in winters. Building new energy sources like dams, coal power plants and renewable energy power projects are some possible solutions, but these are time taking and need at least 2 to 6 years to complete, depending upon the nature of the project. Fast development of energy-efficient buildings is, therefore, necessary to deal with exacerbating energy-crisis and related environmental impact in Pakistan. Innovations in the prevailing building-design will help the country in reducing the energy burden. These innovations may include improved architectural designs, energy-efficient building materials, electrical appliances and implementation of building energy-efficiency codes. In 1987, the National Energy Conservation Centre (ENERCON), was established under Ministry of Environment, Government of Pakistan, with the aim to build awareness among the masses for energy conservation, and to make policies regarding energy-conservation structures in the country. But no policy regarding building energy codes has been introduced by ENERCON till now. In collaboration with Pakistan Engineering Council (PEC), ENERCON has recently finalized the Building Energy Code of Pakistan Energy Provisions 2011 for which statutory notification is under process for necessary amendment in the building by-laws. The implementation of this Energy Code will result in 25 to 30 % of energy savings in the

  1. Seismic performance of existing R.C. framed buildings

    Directory of Open Access Journals (Sweden)

    Sameh A. El-Betar

    2017-08-01

    Full Text Available The earthquakes disasters basically occur due to buildings damage not because of the earth shaking. Therefore, the countries have being updated the seismic codes. The seismic loads for buildings design in Egyptian Code have been changed from (EC-1994 to (ECP-201, 2012. On the other hand, the need is raised to study the vulnerability of existing buildings, which can be divided into the buildings designed to resist the gravity loads only (GLD and the buildings designed according to Egyptian code (EC-1994. Comparison between forces due to Egyptian code for loads (EC-1994 and (ECP-201, 2012 is carried out on the multi-stories R.C. framed buildings which are the most common type of existing buildings in Egypt. To investigate the vulnerability of existing buildings, nonlinear static pushover analysis is conducted to evaluate the real strength of the existing buildings. Moreover, it is considered a useful and effective tool for the performance of three framed buildings: 3, 6 and 10 stories due to expected future earthquakes. Finally, it is found that the vulnerability of existing GLD buildings occurs at expected ground accelerations (ag greater than 0.125 g in Egyptian seismic map, while the EC-94 designed buildings behave elastically up to (ag equals to 0.2 g and above that a slight damage may occur.

  2. Assessment of the Internal Pressure Fragility of the Hanul NPP Units 3 and 4 Containment Building Using a Nonlinear Finite Element Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung Kui; Hahm, Dea Gi; Choi, In Kil [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The sensitivity of the concrete strength is relatively higher compared to that of the steel strength. According to changes in the structure of the material, about 6-10% ultimate internal pressure differences occurred. Thirty sets of an FE model considering the material uncertainty of concrete and steel were composed for the internal pressure fragility assessment. From the internal pressure fragility assessment of the target containment building, the median capacity of liner leakage is estimated to be 116 psi. As can be seen from the Fukushima nuclear power plant accident, the containment building is the final protecting shield to prevent radiation leakage. Thus, a structural soundness evaluation for the containment pressure loads owing to a severe accident is very important. Recently, a probabilistic safety assessment has been commonly used to take into account the possible factors of uncertainty in a structural system. An assessment of the internal pressure fragility of the CANDU type containment buildings considering the correlation of structural material variables, and an assessment of the internal pressure fragility of the CANDU type containment buildings using a nonlinear finite element analysis, were also performed. However, for PWR type containment buildings, a fragility assessment has not been performed yet using a nonlinear finite element model (FEM) analysis. In this study, for the Hanul NPP units 3 and 4 containment building, the internal pressure fragility assessment was established using an FEM analysis. To do this, a three-dimensional finite element model, material property values, and a sensitive analysis were developed. A nonlinear finite element analysis of the Hanul NPP units 3 and 4 containment building was performed for a material sensitivity analysis and internal pressure fragility assessment.

  3. Assessment of the Internal Pressure Fragility of the Hanul NPP Units 3 and 4 Containment Building Using a Nonlinear Finite Element Analysis

    International Nuclear Information System (INIS)

    Park, Hyung Kui; Hahm, Dea Gi; Choi, In Kil

    2013-01-01

    The sensitivity of the concrete strength is relatively higher compared to that of the steel strength. According to changes in the structure of the material, about 6-10% ultimate internal pressure differences occurred. Thirty sets of an FE model considering the material uncertainty of concrete and steel were composed for the internal pressure fragility assessment. From the internal pressure fragility assessment of the target containment building, the median capacity of liner leakage is estimated to be 116 psi. As can be seen from the Fukushima nuclear power plant accident, the containment building is the final protecting shield to prevent radiation leakage. Thus, a structural soundness evaluation for the containment pressure loads owing to a severe accident is very important. Recently, a probabilistic safety assessment has been commonly used to take into account the possible factors of uncertainty in a structural system. An assessment of the internal pressure fragility of the CANDU type containment buildings considering the correlation of structural material variables, and an assessment of the internal pressure fragility of the CANDU type containment buildings using a nonlinear finite element analysis, were also performed. However, for PWR type containment buildings, a fragility assessment has not been performed yet using a nonlinear finite element model (FEM) analysis. In this study, for the Hanul NPP units 3 and 4 containment building, the internal pressure fragility assessment was established using an FEM analysis. To do this, a three-dimensional finite element model, material property values, and a sensitive analysis were developed. A nonlinear finite element analysis of the Hanul NPP units 3 and 4 containment building was performed for a material sensitivity analysis and internal pressure fragility assessment

  4. Thermal Comfort and Ventilation Criteria for low Energy Residential Buildings in Building Codes

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kurnitski, Jarek; Awbi, Hazim

    2012-01-01

    of the indoor air quality in such buildings. Currently, there are no global guidelines for specifying the indoor thermal environment in such low-energy buildings. The objective of this paper is to analyse the classification of indoor thermal comfort levels and recommended ventilation rates for different low...

  5. Benchmarking severe accident computer codes for heavy water reactor applications

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.H. [International Atomic Energy Agency, Vienna (Austria)

    2010-07-01

    Consideration of severe accidents at a nuclear power plant (NPP) is an essential component of the defence in depth approach used in nuclear safety. Severe accident analysis involves very complex physical phenomena that occur sequentially during various stages of accident progression. Computer codes are essential tools for understanding how the reactor and its containment might respond under severe accident conditions. International cooperative research programmes are established by the IAEA in areas that are of common interest to a number of Member States. These co-operative efforts are carried out through coordinated research projects (CRPs), typically 3 to 6 years in duration, and often involving experimental activities. Such CRPs allow a sharing of efforts on an international basis, foster team-building and benefit from the experience and expertise of researchers from all participating institutes. The IAEA is organizing a CRP on benchmarking severe accident computer codes for heavy water reactor (HWR) applications. The CRP scope includes defining the severe accident sequence and conducting benchmark analyses for HWRs, evaluating the capabilities of existing computer codes to predict important severe accident phenomena, and suggesting necessary code improvements and/or new experiments to reduce uncertainties. The CRP has been planned on the advice and with the support of the IAEA Nuclear Energy Department's Technical Working Groups on Advanced Technologies for HWRs. (author)

  6. Coding for Electronic Mail

    Science.gov (United States)

    Rice, R. F.; Lee, J. J.

    1986-01-01

    Scheme for coding facsimile messages promises to reduce data transmission requirements to one-tenth current level. Coding scheme paves way for true electronic mail in which handwritten, typed, or printed messages or diagrams sent virtually instantaneously - between buildings or between continents. Scheme, called Universal System for Efficient Electronic Mail (USEEM), uses unsupervised character recognition and adaptive noiseless coding of text. Image quality of resulting delivered messages improved over messages transmitted by conventional coding. Coding scheme compatible with direct-entry electronic mail as well as facsimile reproduction. Text transmitted in this scheme automatically translated to word-processor form.

  7. Use of MCAM in creating 3D neutronics model for ITER building

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Qin [Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China); Wang Guozhong, E-mail: mango33@mail.ustc.edu.cn [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China); Dang Tongqiang [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China); Long Pengcheng [Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China); Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lz-Durance (France)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer We created a 3D neutronics model of the ITER building. Black-Right-Pointing-Pointer The model was produced from the engineering CAD model by MCAM software. Black-Right-Pointing-Pointer The neutron flux map in the ITER building was calculated. - Abstract: The three dimensional (3D) neutronics reference model of International Thermonuclear Experimental Reactor (ITER) only defines the tokamak machine and extends to the bio-shield. In order to meet further 3D neutronics analysis needs, it is necessary to create a 3D reference model of the ITER building. Monte Carlo Automatic Modeling Program for Radiation Transport Simulation (MCAM) was developed as a computer aided design (CAD) based bi-directional interface program between general CAD systems and Monte Carlo radiation transport simulation codes. With the help of MCAM version 4.8, the 3D neutronics model of ITER building was created based on the engineering CAD model. The calculation of the neutron flux map in ITER building during operation showed the correctness and usability of the model. This model is the first detailed ITER building 3D neutronics model and it will be made available to all international organization collaborators as a reference model.

  8. HBT+: an improved code for finding subhaloes and building merger trees in cosmological simulations

    Science.gov (United States)

    Han, Jiaxin; Cole, Shaun; Frenk, Carlos S.; Benitez-Llambay, Alejandro; Helly, John

    2018-02-01

    Dark matter subhalos are the remnants of (incomplete) halo mergers. Identifying them and establishing their evolutionary links in the form of merger trees is one of the most important applications of cosmological simulations. The HBT (Hierachical Bound-Tracing) code identifies haloes as they form and tracks their evolution as they merge, simultaneously detecting subhaloes and building their merger trees. Here we present a new implementation of this approach, HBT+ , that is much faster, more user friendly, and more physically complete than the original code. Applying HBT+ to cosmological simulations, we show that both the subhalo mass function and the peak-mass function are well fitted by similar double-Schechter functions. The ratio between the two is highest at the high-mass end, reflecting the resilience of massive subhaloes that experience substantial dynamical friction but limited tidal stripping. The radial distribution of the most-massive subhaloes is more concentrated than the universal radial distribution of lower mass subhaloes. Subhalo finders that work in configuration space tend to underestimate the masses of massive subhaloes, an effect that is stronger in the host centre. This may explain, at least in part, the excess of massive subhaloes in galaxy cluster centres inferred from recent lensing observations. We demonstrate that the peak-mass function is a powerful diagnostic of merger tree defects, and the merger trees constructed using HBT+ do not suffer from the missing or switched links that tend to afflict merger trees constructed from more conventional halo finders. We make the HBT+ code publicly available.

  9. Simulation of International Standard Problem No. 44 'KAEVER' experiments on aerosol behaviour with the CONTAIN code

    International Nuclear Information System (INIS)

    Kljenak, I.

    2001-01-01

    Experiments on aerosol behavior in a vapor-saturated atmosphere, which were performed in the KAEVER experimental facility and proposed for the OECD International Standard Problem No. 44, were simulated with the CONTAIN thermal-hydraulic computer code. The purpose of the work was to assess the capability of the CONTAIN code to model aerosol condensation and deposition in a containment of a light-water-reactor nuclear power plant at severe accident conditions. Results of dry and wet aerosol concentrations are presented and analyzed.(author)

  10. The fundamentals of structural building codes

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2001-01-01

    Partial Factor Design is nowadays a generally accepted design method for building and civil engineering structures. For most engineers the general philosophy that the safety factors depend on the type of the load and on the limit state under consideration makes sense. However, the background, in

  11. Implementation of the International Code of Marketing of Breastmilk Substitutes in the Eastern Mediterranean Region.

    Science.gov (United States)

    Al Jawaldeh, Ayoub; Sayed, Ghada

    2018-04-05

    Optimal breastfeeding practices and appropriate complementary feeding improve child health, survival and development. The countries of the Eastern Mediterranean Region have made significant strides in formulation and implementation of legislation to protect and promote breastfeeding based on The International Code of Marketing of Breast-milk Substitutes (the Code) and subsequent relevant World Health Assembly resolutions. To assess the implementation of the Code in the Region. Assessment was conducted by the World Health Organization (WHO) Regional Office for the Eastern Mediterranean using a WHO standard questionnaire. Seventeen countries in the Region have enacted legislation to protect breastfeeding. Only 6 countries have comprehensive legislation or other legal measures reflecting all or most provisions of the Code; 4 countries have legal measures incorporating many provisions of the Code; 7 countries have legal measures that contain a few provisions of the Code; 4 countries are currently studying the issue; and only 1 country has no measures in place. Further analysis of the legislation found that the text of articles in the laws fully reflected the Code articles in only 6 countries. Most countries need to revisit and amend existing national legislation to implement fully the Code and relevant World Health Assembly resolutions, supported by systematic monitoring and reporting. Copyright © World Health Organization (WHO) 2018. Some rights reserved. This work is available under the CC BY-NC-SA 3.0 IGO license (https://creativecommons.org/licenses/by-nc-sa/3.0/igo).

  12. The added value of international benchmarks for fuel performance codes: an illustration on the basis of TRANSURANUS

    International Nuclear Information System (INIS)

    Van Uffelen, P.; Schubert, A.; Gyeori, C.; Van De Laar, J.

    2009-01-01

    Safety authorities and fuel designers, as well as nuclear research centers rely heavily on fuel performance codes for predicting the behaviour and life-time of fuel rods. The simulation tools are developed and validated on the basis of experimental results, some of which is in the public domain such as the International Fuel Performance Experiments database of the OECD/NEA and IAEA. Publicly available data constitute an excellent basis for assessing codes themselves, but also to compare codes that are being developed by independent teams. The present report summarises the advantages for the TRANSURANUS code by taking part in previous benchmarks organised by the IAEA, and outlines the preliminary results along with the perspectives of our participation in the current coordinated research project FUMEXIII

  13. Building a dynamic code to simulate new reactor concepts

    International Nuclear Information System (INIS)

    Catsaros, N.; Gaveau, B.; Jaekel, M.-T.; Maillard, J.; Maurel, G.; Savva, P.; Silva, J.; Varvayanni, M.

    2012-01-01

    Highlights: ► We develop a stochastic neutronic code based on an existing High Energy Physics code. ► The code simulates innovative reactor designs including Accelerator Driven Systems. ► Core materials evolution will be dynamically simulated, including fuel burnup. ► Continuous feedback between the main inter-related parameters will be established. ► A description of the current research development and achievements is also given. - Abstract: Innovative nuclear reactor designs have been proposed, such as the Accelerator Driven Systems (ADSs), the “candle” reactors, etc. These reactor designs introduce computational nuclear technology problems the solution of which necessitates a new, global and dynamic computational approach of the system. A continuous feedback procedure must be established between the main inter-related parameters of the system such as the chemical, physical and isotopic composition of the core, the neutron flux distribution and the temperature field. Furthermore, as far as ADSs are concerned, the ability of the computational tool to simulate the nuclear cascade created from the interaction of accelerated protons with the spallation target as well as the produced neutrons, is also required. The new Monte Carlo code ANET (Advanced Neutronics with Evolution and Thermal hydraulic feedback) is being developed based on the GEANT3 High Energy Physics code, aiming to progressively satisfy all the above requirements. A description of the capabilities and methodologies implemented in the present version of ANET is given here, together with some illustrative applications of the code.

  14. Proposal to modify Rule 10a and to delete Recommendation 10a(3) from the International Code of Nomenclature of Prokaryotes.

    Science.gov (United States)

    Oren, Aharon

    2017-09-01

    Principle 2 of the Prokaryotic Code, as modified by the ICSP in 1999, reads: 'The nomenclature of prokaryotes is not independent of botanical and zoological nomenclature. When naming new taxa in the rank of genus or higher, due consideration is to be given to avoiding names which are regulated by the International Code of Zoological Nomenclature and the International Code of Nomenclature for algae, fungi and plants'. But in the current version of the Prokaryotic Code no Rule implements this version of Principle 2. I therefore propose adding the following sentence to Rule 10a: 'As from January 2001, newly proposed generic names must not be later homonyms of names in use in botany or zoology'. Recommendation 10a(3) of the Code states: 'Avoid introducing into bacteriology as generic names such names as are in use in botany or zoology, in particular well-known names'. This Recommendation contravenes the current version of Principle 2 and the proposed new version of Rule 10a. Therefore I propose to delete Recommendation 10a(3) from the Prokaryotic Code.

  15. INDOSE V2.1.1, Internal Dosimetry Code Using Biokinetics Models

    International Nuclear Information System (INIS)

    Silverman, Ido

    2002-01-01

    A - Description of program or function: InDose is an internal dosimetry code developed to enable dose estimations using the new biokinetic models (presented in ICRP-56 to ICRP71) as well as the old ones. The code is written in FORTRAN90 and uses the ICRP-66 respiratory tract model and the ICRP-30 gastrointestinal tract model as well as the new and old biokinetic models. The code has been written in such a way that the user is able to change any of the parameters of any one of the models without recompiling the code. All the parameters are given in well annotated parameters files that the user may change and the code reads during invocation. As default, these files contains the values listed in ICRP publications. The full InDose code is planed to have three parts: 1) the main part includes the uptake and systemic models and is used to calculate the activities in the body tissues and excretion as a function of time for a given intake. 2) An optimization module for automatic estimation of the intake for a specific exposure case. 3) A module to calculate the dose due to the estimated intake. Currently, the code is able to perform only its main task (part 1) while the other two have to be done externally using other tools. In the future we would like to add these modules in order to provide a complete solution for the people in the laboratory. The code has been tested extensively to verify the accuracy of its results. The verification procedure was divided into three parts: 1) verification of the implementation of each model, 2) verification of the integrity of the whole code, and 3) usability test. The first two parts consisted of comparing results obtained with InDose to published results for the same cases. For example ICRP-78 monitoring data. The last part consisted of participating in the 3. EIE-IDA and assessing some of the scenarios provided in this exercise. These tests where presented in a few publications. It has been found that there is very good agreement

  16. Automation of Geometry Input for Building Code Compliance Check

    DEFF Research Database (Denmark)

    Petrova, Ekaterina Aleksandrova; Johansen, Peter Lind; Jensen, Rasmus Lund

    2017-01-01

    Documentation of compliance with the energy performance regulations at the end of the detailed design phase is mandatory for building owners in Denmark. Therefore, besides multidisciplinary input, the building design process requires various iterative analyses, so that the optimal solutions can....... That has left the industry in constant pursuit of possibilities for integration of the tool within the Building Information Modelling environment so that the potential provided by the latter can be harvested and the processed can be optimized. This paper presents a solution for automated data extraction...... from building geometry created in Autodesk Revit and its translation to input for compliance check analysis....

  17. International standard problem (ISP) no. 41 follow up exercise: Containment iodine computer code exercise: parametric studies

    Energy Technology Data Exchange (ETDEWEB)

    Ball, J.; Glowa, G.; Wren, J. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Ewig, F. [GRS Koln (Germany); Dickenson, S. [AEAT, (United Kingdom); Billarand, Y.; Cantrel, L. [IPSN (France); Rydl, A. [NRIR (Czech Republic); Royen, J. [OECD/NEA (France)

    2001-11-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I{sup -} concentration. The codes used in this exercise were IODE(IPSN), IODE(NRIR), IMPAIR(GRS), INSPECT(AEAT), IMOD(AECL) and LIRIC(AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained front intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility, (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (author)

  18. International standard problem (ISP) no. 41 follow up exercise: Containment iodine computer code exercise: parametric studies

    International Nuclear Information System (INIS)

    Ball, J.; Glowa, G.; Wren, J.; Ewig, F.; Dickenson, S.; Billarand, Y.; Cantrel, L.; Rydl, A.; Royen, J.

    2001-11-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I - concentration. The codes used in this exercise were IODE(IPSN), IODE(NRIR), IMPAIR(GRS), INSPECT(AEAT), IMOD(AECL) and LIRIC(AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained front intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility, (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (author)

  19. A2 Code - Internal Accident Report. Does it ring a bell?

    CERN Document Server

    HSE Unit

    2015-01-01

    A2 Code* - It is under this designation (used by the CERN community) that the form for internal accident reports is hidden. More specifically it refers to the CERN Safety Code A2 “Reporting of Accidents and Near Misses” (EDMS: 335502 or here via the official Safety Rules website).   Which events should be declared? All accidental events, which cause or could have caused injuries or damage to property or the environment, must be reported especially if they involve: a) a member of the personnel, visitor, temporary labourer or contractor if it occurred on the CERN site or between sites. b) a member of the personnel if it occurred while commuting or during duty travel. Who can fill in the report? The reporting of occurred accidents or near misses should be made by the person involved or by any direct or indirect witness of the event as soon as possible after the event. Contribute to the improvement of Safety within the Organizatio...

  20. Intracoin - International Nuclide Transport Code Intercomparison Study

    International Nuclear Information System (INIS)

    1984-09-01

    The purpose of the project is to obtain improved knowledge of the influence of various strategies for radionuclide transport modelling for the safety assessment of final repositories for nuclear waste. This is a report of the first phase of the project which was devoted to a comparison of the numerical accuracy of the computer codes used in the study. The codes can be divided into five groups, namely advection-dispersion models, models including matrix diffusion and chemical effects and finally combined models. The results are presented as comparisons of calculations since the objective of level 1 was code verification. (G.B.)

  1. Seismic assessment of existing RC buildings under alternative ground motion ensembles compatible to EC8 and NTC 2008

    NARCIS (Netherlands)

    Tanganelli, Marco; Viti, Stefania; Mariani, V.; Pianigiani, Maria

    2017-01-01

    This work investigates the effects of the choice of different ensembles of ground motions on the seismic assessment of existing RC buildings through nonlinear dynamic analysis. Nowadays indeed, all the main International Seismic Codes provide a soil classification which is based on the shear wave

  2. Defining pediatric traumatic brain injury using International Classification of Diseases Version 10 Codes: a systematic review.

    Science.gov (United States)

    Chan, Vincy; Thurairajah, Pravheen; Colantonio, Angela

    2015-02-04

    Although healthcare administrative data are commonly used for traumatic brain injury (TBI) research, there is currently no consensus or consistency on the International Classification of Diseases Version 10 (ICD-10) codes used to define TBI among children and youth internationally. This study systematically reviewed the literature to explore the range of ICD-10 codes that are used to define TBI in this population. The identification of the range of ICD-10 codes to define this population in administrative data is crucial, as it has implications for policy, resource allocation, planning of healthcare services, and prevention strategies. The databases MEDLINE, MEDLINE In-Process, Embase, PsychINFO, CINAHL, SPORTDiscus, and Cochrane Database of Systematic Reviews were systematically searched. Grey literature was searched using Grey Matters and Google. Reference lists of included articles were also searched for relevant studies. Two reviewers independently screened all titles and abstracts using pre-defined inclusion and exclusion criteria. A full text screen was conducted on articles that met the first screen inclusion criteria. All full text articles that met the pre-defined inclusion criteria were included for analysis in this systematic review. A total of 1,326 publications were identified through the predetermined search strategy and 32 articles/reports met all eligibility criteria for inclusion in this review. Five articles specifically examined children and youth aged 19 years or under with TBI. ICD-10 case definitions ranged from the broad injuries to the head codes (ICD-10 S00 to S09) to concussion only (S06.0). There was overwhelming consensus on the inclusion of ICD-10 code S06, intracranial injury, while codes S00 (superficial injury of the head), S03 (dislocation, sprain, and strain of joints and ligaments of head), and S05 (injury of eye and orbit) were only used by articles that examined head injury, none of which specifically examined children and

  3. Improving the coding and classification of ambulance data through the application of International Classification of Disease 10th revision.

    Science.gov (United States)

    Cantwell, Kate; Morgans, Amee; Smith, Karen; Livingston, Michael; Dietze, Paul

    2014-02-01

    This paper aims to examine whether an adaptation of the International Classification of Disease (ICD) coding system can be applied retrospectively to final paramedic assessment data in an ambulance dataset with a view to developing more fine-grained, clinically relevant case definitions than are available through point-of-call data. Over 1.2 million case records were extracted from the Ambulance Victoria data warehouse. Data fields included dispatch code, cause (CN) and final primary assessment (FPA). Each FPA was converted to an ICD-10-AM code using word matching or best fit. ICD-10-AM codes were then converted into Major Diagnostic Categories (MDC). CN was aligned with the ICD-10-AM codes for external cause of morbidity and mortality. The most accurate results were obtained when ICD-10-AM codes were assigned using information from both FPA and CN. Comparison of cases coded as unconscious at point-of-call with the associated paramedic assessment highlighted the extra clinical detail obtained when paramedic assessment data are used. Ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Coding of ambulance data using ICD-10-AM allows for comparison of not only ambulance service users but also with other population groups. WHAT IS KNOWN ABOUT THE TOPIC? There is no reliable and standard coding and categorising system for paramedic assessment data contained in ambulance service databases. WHAT DOES THIS PAPER ADD? This study demonstrates that ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Representation of ambulance case types using ICD-10-AM-coded information obtained after paramedic assessment is more fine grained and clinically relevant than point-of-call data, which uses caller information before ambulance attendance. WHAT ARE THE IMPLICATIONS FOR PRACTITIONERS? This paper describes

  4. Prediction of hydrogen distribution in the reactor building in CANDU6 plant

    International Nuclear Information System (INIS)

    Jin, Y.; Song, Y.

    2008-01-01

    The CANDU plants have a lot of zircaloy. The fuel cladding, calandria tubes and pressure tubes are made of zircaloy. The zircaloy can be oxidized and hydrogen is generated during severe accident progression. The detonation or deflagration to detonation transition (DDT) due to hydrogen combustion may occur if the local hydrogen concentration or global hydrogen concentration exceeds certain value. The detonation may result in the rupture of the reactor building. The inside of the reactor building of CANDU plants is complex. So prediction of hydrogen distribution in the reactor building is important. This prediction is made using ISAAC code and GOTHIC code. ISAAC code partitioned the reactor building in to 7 compartments. GOTHIC code modeled the CANDU6 reactor building using 12 nodes. The hydrogen concentrations in the various compartments in the reactor building are compared. GOTHIC code slightly underpredicts hydrogen concentration in the F/M rooms than ISAAC code, but trend is same. The hydrogen concentration in the boiler room and the moderator room shows almost same as for both codes. (author)

  5. Differences in perception of the WHO International Code of Marketing of Breast Milk Substitutes between pediatricians and obstetricians in Japan

    Directory of Open Access Journals (Sweden)

    Macnab Iona

    2006-08-01

    Full Text Available Abstract Background The World Health Organization International Code of Marketing of Breast-Milk Substitutes (WHO Code aims to protect and promote breastfeeding. Japan ratified the WHO Code in 1994, but most hospitals in Japan continue to receive free supplies of infant formula and distribute discharge packs to new mothers provided by infant formula companies. The aim of this study was to explore the knowledge and attitudes of pediatricians and obstetricians in Japan to the WHO Code. Methods A self-completion questionnaire was sent to 132 pediatricians in the 131 NICUs which belonged to the Neonatal Network of Japan, and to 96 chief obstetricians in the general hospitals in the Kanto area of Japan, in 2004. Results Responses were received from 68% of pediatricians and 64% of obstetricians. Sixty-six percent of pediatricians agreed that "Breastmilk is the best", compared to only 13% of obstetricians. Likewise, pediatricians were more likely to be familiar with the WHO Code (51% than obstetricians (18%. Conclusion In Japan, pediatricians and obstetricians, in general, have low levels of support for breastfeeding and low levels of familiarity with the WHO Code. To increase the breastfeeding rates in Japan, both pediatricians and obstetricians need increased knowledge about current infant feeding practices and increased awareness of international policies to promote breastfeeding.

  6. A proposed framework for computational fluid dynamics code calibration/validation

    International Nuclear Information System (INIS)

    Oberkampf, W.L.

    1993-01-01

    The paper reviews the terminology and methodology that have been introduced during the last several years for building confidence n the predictions from Computational Fluid Dynamics (CID) codes. Code validation terminology developed for nuclear reactor analyses and aerospace applications is reviewed and evaluated. Currently used terminology such as ''calibrated code,'' ''validated code,'' and a ''validation experiment'' is discussed along with the shortcomings and criticisms of these terms. A new framework is proposed for building confidence in CFD code predictions that overcomes some of the difficulties of past procedures and delineates the causes of uncertainty in CFD predictions. Building on previous work, new definitions of code verification and calibration are proposed. These definitions provide more specific requirements for the knowledge level of the flow physics involved and the solution accuracy of the given partial differential equations. As part of the proposed framework, categories are also proposed for flow physics research, flow modeling research, and the application of numerical predictions. The contributions of physical experiments, analytical solutions, and other numerical solutions are discussed, showing that each should be designed to achieve a distinctively separate purpose in building confidence in accuracy of CFD predictions. A number of examples are given for each approach to suggest methods for obtaining the highest value for CFD code quality assurance

  7. International technology transfer for climate change mitigation and the cases of Russia and China

    International Nuclear Information System (INIS)

    Martinot, E.; Sinton, J.E.

    1997-01-01

    The environmental agenda for mitigating climate change through international transfers of technology is linked with a diverse literature, reviewed here within a framework that combines technological, agent/agenda, and market/transaction perspectives. Literature that bears on international technology transfer for climate change mitigation is similar in many ways for Russia and China: opportunities for energy efficiency and renewable energy, economic reform and restructuring, the difficulties enterprises face in responding to market conditions, international assistance policies, international joint ventures, market intermediation, and capacity building for market development. In both countries, capacity building means enhancing market-oriented capabilities in addition to technological capabilities. For Russia, institutional development is critical, such as new commercial legal codes and housing-sector changes beyond privatization. For China, technology policies and modernization programs significantly influence technology transfers. 234 refs., 3 tabs

  8. International technology transfer for climate change mitigation and the cases of Russia and China

    Energy Technology Data Exchange (ETDEWEB)

    Martinot, E. [Univ. of California, Berkeley, CA (United States). Energy and Resources Group]|[Stockholm Environment Inst., Boston, MA (United States); Sinton, J.E. [Univ. of California, Berkeley, CA (United States). Energy and Resources Group]|[Lawrence Berkeley National Lab., CA (United States). International Energy Studies Group; Haddad, B.M. [Univ. of California, Berkeley, CA (United States)

    1997-12-31

    The environmental agenda for mitigating climate change through international transfers of technology is linked with a diverse literature, reviewed here within a framework that combines technological, agent/agenda, and market/transaction perspectives. Literature that bears on international technology transfer for climate change mitigation is similar in many ways for Russia and China: opportunities for energy efficiency and renewable energy, economic reform and restructuring, the difficulties enterprises face in responding to market conditions, international assistance policies, international joint ventures, market intermediation, and capacity building for market development. In both countries, capacity building means enhancing market-oriented capabilities in addition to technological capabilities. For Russia, institutional development is critical, such as new commercial legal codes and housing-sector changes beyond privatization. For China, technology policies and modernization programs significantly influence technology transfers. 234 refs., 3 tabs.

  9. Enhancement of seismic resistance of buildings

    Directory of Open Access Journals (Sweden)

    Claudiu-Sorin Dragomir

    2014-03-01

    Full Text Available The objectives of the paper are both seismic instrumentation for damage assessment and enhancing of seismic resistance of buildings. In according with seismic design codes in force the buildings are designed to resist at seismic actions. Due to the time evolution of these design provisions, there are buildings that were designed decades ago, under the less stringent provisions. The conceptual conformation is nowadays provided in all Codes of seismic design. According to the Code of seismic design P100-1:2006 the asymmetric structures do not have an appropriate seismic configuration; they have disadvantageous distribution of volumes, mass and stiffness. Using results of temporary seismic instrumentation the safety condition of the building may be assessed in different phases of work. Based on this method, the strengthening solutions may be identified and the need of seismic joints may be emphasised. All the aforementioned ideas are illustrated through a case study. Therefore it will be analysed the dynamic parameter evolution of an educational building obtained in different periods. Also, structural intervention scenarios to enhance seismic resistance will be presented.

  10. Coding Bootcamps : Building Future-Proof Skills through Rapid Skills Training

    OpenAIRE

    World Bank

    2017-01-01

    This report studies coding bootcamps. A new kind of rapid skills training program for the digital age. Coding bootcamps are typically short-term (three to six months), intensive and applied training courses provided by a third party that crowdsources the demand for low-skills tech talent. Coding bootcamps aim at low-entry level tech employability (for example, junior developer), providing a ...

  11. Training program for energy conservation in new-building construction. Volume II. Energy conservation technology: for the building inspector

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    A Model Code for Energy Conservation in New Building Construction has been developed by those national organizations primarily concerned with the development and promulgation of model codes. The technical provisions are based on ASHRAE Standard 90-75 and are intended for use by state and local officials. This training manual contains the basic information necessary to acquaint the field building inspector with the concepts of energy conservation in buildings and instructs him in the basic techniques of field inspection of energy compliance.

  12. International vs. domestic technology in-licensing: How do Chinese firms build their technological capabilities?

    DEFF Research Database (Denmark)

    Li, Ying; Wang, Yuandi

    2011-01-01

    This paper investigates the different impacts of international and domestic technology in-licensing for Chinese firms as licensees on their technological capability building. The evolution of firms in developing countries and development of their technological capabilities has received increasing...... attention in the extant literature on both innovation management and international business. However, little has been done to reach a clear understanding on whether Chinese firms can benefit from international or domestic technology in-licensing and improve their own technological capabilities. This study......, therefore, pursues this endeavor by using a unique dataset from China State of Intellectual Property Office (SIPO) containing information on large Chinese firms. The findings of this empirical study indicate that firms with international technology in-licensing possess stronger technological innovation...

  13. International Code Centres Network. Summary Report of the 3rd Biennial Technical Meeting

    International Nuclear Information System (INIS)

    Chung, Hyun-Kyung

    2013-07-01

    This report summarizes the proceedings of the third Technical Meeting of the International Code Centres Network held on 6-8 May in 2013. Ten experts from seven member states and four IAEA staff members attended the three-day meeting held at the IAEA Headquarters in Vienna to discuss issues on uncertainty estimates of theoretical atomic and molecular data. The report includes discussions on data issues, meeting conclusions and recommendations for the IAEA Atomic and Molecular Data Unit. (author)

  14. A Bibliometric Review on Risk Management and Building Information Modeling for International Construction

    Directory of Open Access Journals (Sweden)

    Tsenguun Ganbat

    2018-01-01

    Full Text Available International construction is complicated and involves high risks. However, with the development of technological innovation, Building Information Modeling (BIM emerged and seems to be able to address certain risks. To understand BIM applications in risk management for international construction, a state-of-the-art review is required. Therefore, this paper aims to identify the research trends and opportunities for risk management in BIM-enabled international construction by reviewing 526 peer-reviewed journal articles for the years 2007–2017. Thus five steps of bibliometric analysis were conducted based on the proposed frameworks of BIM risk management in international construction (BIM-RM-INTL. The results show that the popularization of BIM not only attracts all stakeholders’ interests but also brings some risks. For example, financial factors are hard to detect and control through BIM, information loss during transmission stands out, and BIM has no unified standards and regulations for international construction. The research has mapped existing research results and their relationships for future risk management in BIM-enabled international construction.

  15. Implementation of probabilistic safety concepts in international codes

    International Nuclear Information System (INIS)

    Borges, J.F.

    1977-01-01

    Recent progress in the implementation of safety concepts in international structure codes is briefly presented. Special attention is paid to the work of the Joint-Committee on Structural Safety. The discussion is centered on some problems such as: safety differentiation, definition and combination of actions, spaces for checking safety and non-linear structural behaviour. When discussing safety differentiation it should be considered that the total probability of failure derives from a theoretical probability of failure and a probability of failure due to error and gross negligence. Optimization of design criteria should take into account both causes of failure. The quantification of reliability implies a probabilistic idealization of all basic variables. Steps taken to obtain an improved definition of different types of actions and rules for their combination are described. Safety checking can be carried out in terms of basic variables, action-effects, or any other suitable variable. However, the advantages and disadvantages of the different types of formulation should be discussed, particularly in the case of non-linear structural behaviour. (orig.) [de

  16. Climate Change Mitigation through Energy Benchmarking in the GCC Green Buildings Codes

    Directory of Open Access Journals (Sweden)

    Yousef Alhorr

    2015-06-01

    Full Text Available It is well known that the Gulf Cooperation Council (GCC of countries resides at or close to the top of the global table of CO2 emissions per capita and its economy relies heavily on its fossil fuels. This provides a context for green building programs that initially aim to create an understanding of emission pathways within the GCC and hence develop approaches to their reduction in the built environment. A set of criteria will allow specific analysis to be undertaken linked to the spatial dimensions of the sector under study. In this paper, approaches to modelling energy consumption and CO2 emissions are presented. As investment in the built environment continues, natural resources dwindle and the cost of energy increases, delivering low-energy buildings will become mandatory. In this study, a hybrid modelling approach (bottom-top & top-bottom is presented. Energy benchmarks are developed for different buildings’ uses and compared with international standards. The main goals are to establish design benchmarks and develop a modelling tool that contains specific information for all buildings types (existing and new, as well as planned and projected growths within the various city districts, then integrate this database within a geospatial information system that will allow us to answer a range of “what-if”-type questions about various intervention strategies, emissions savings, and acceptability of pre-defined course of actions in the city sector under consideration. The spatial carbon intensity may be adjusted over a certain period, (e.g., through local generation (microgeneration or due to an increasing proportion of lower carbon-energy in the generation mix and this can be related to the sector and city overall consumption.

  17. The International Atomic Energy Agency Flag Code

    International Nuclear Information System (INIS)

    1999-01-01

    The document reproduces the text of the IAEA Flag Code which was promulgated by the Director General on 15 September 1999, pursuant to the decision of the Board of Governors on 10 June 1999 to adopt an Agency flag as described in document GOV/1999/41 and its use in accordance with a flag code to be promulgated by the Director General

  18. The International Atomic Energy Agency Flag Code

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-17

    The document reproduces the text of the IAEA Flag Code which was promulgated by the Director General on 15 September 1999, pursuant to the decision of the Board of Governors on 10 June 1999 to adopt an Agency flag as described in document GOV/1999/41 and its use in accordance with a flag code to be promulgated by the Director General.

  19. A Guide to Building Commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, Michael C.

    2011-09-01

    Commissioning is the process of verifying that a building's heating, ventilation, and air conditioning (HVAC) and lighting systems perform correctly and efficiently. Without commissioning, system and equipment problems can result in higher than necessary utility bills and unexpected and costly equipment repairs. This report reviews the benefits of commissioning, why it is a requirement for Leadership in Energy and Environmental Design (LEED) certification, and why building codes are gradually adopting commissioning activities into code.

  20. Analysis of the Earthquake-Resistant Design Approach for Buildings in Mexico

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2014-01-01

    Full Text Available The development of new codes for earthquake-resistant structures has made possible to guarantee a better performance of buildings, when they are subjected to seismic actions. Therefore, it is convenient that current codes for design of building become conceptually transparent when defining the strength modification factors and assessing maximum lateral displacements, so that the design process can be clearly understood by structural engineers. The aim of this study is to analyze the transparency of earthquake-resistant design approach for buildings in Mexico by means of a critical review of the factors for strength modification and displacement amplification. The approach of building design codes in US is also analyzed. It is concluded that earthquake-resistant design in Mexico have evolved in refinement and complexity. It is also demonstrated that the procedure prescribed by such design codes allows the assessment of the design strengths and displacements in a more rational way, in accordance not only with the present stage of knowledge but also with the contemporary tendencies in building codes. In contrast, the procedures used in US codes may not provide a clear view for seismic response assessment of buildings.

  1. Automation of Geometry Input for Building Code Compliance Check

    DEFF Research Database (Denmark)

    Petrova, Ekaterina Aleksandrova; Johansen, Peter Lind; Jensen, Rasmus Lund

    2017-01-01

    Documentation of compliance with the energy performance regulations at the end of the detailed design phase is mandatory for building owners in Denmark. Therefore, besides multidisciplinary input, the building design process requires various iterative analyses, so that the optimal solutions can b...

  2. Sustainable Building Operation

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole

    2009-01-01

    of sustainable building operation and a survey amongst building administrators from the private and the social housing sector. Our results show that there are many good examples on sustainable building operation in Danish housing estates, where local building managers, residents etc. have gained impressive......Energy-savings in the existing building stock have becomes a main goal in national and international policies. Often focus is on building-renovations, whereas the potential of sustainable building operation to a large extent has been neglected. Nevertheless, international research as well...... as practical experiences from Danish housing estates indicates that there are large potentials for energy savings by focusing on the operation of the buildings. We suggest that in order to achieve sustainability in the existing housing, renovation and operations should be seen as integrated parts...

  3. Learning from Abruzzo earthquake buildings behaviour seen from the Building According-to-the-book perspectives

    International Nuclear Information System (INIS)

    Bazurro, P.; Benedettini, F.; Clemente, P.; Salvatori, A.

    2009-01-01

    A brief description, with the related photographs, is reported on the effects of the recent Abruzzo earthquake on buildings, particularly reinforced-concrete and masonry buildings. Following an overview of the technical building codes particularly focused on the area of L'Aquila, mention is made of cultural heritage structures. [it

  4. Automating RPM Creation from a Source Code Repository

    Science.gov (United States)

    2012-02-01

    apps/usr --with- libpq=/apps/ postgres make rm -rf $RPM_BUILD_ROOT umask 0077 mkdir -p $RPM_BUILD_ROOT/usr/local/bin mkdir -p $RPM_BUILD_ROOT...from a source code repository. %pre %prep %setup %build ./autogen.sh ; ./configure --with-db=/apps/db --with-libpq=/apps/ postgres make

  5. Automation of Geometry Input for Building Code Compliance Check

    DEFF Research Database (Denmark)

    Petrova, Ekaterina Aleksandrova; Johansen, Peter Lind; Jensen, Rasmus Lund

    2017-01-01

    Documentation of compliance with the energy performance regulations at the end of the detailed design phase is mandatory for building owners in Denmark. Therefore, besides multidisciplinary input, the building design process requires various iterative analyses, so that the optimal solutions can...... be identified amongst multiple alternatives. However, meeting performance criteria is often associated with manual data inputs and retroactive modifications of the design. Due to poor interoperability between the authoring tools and the compliance check program, the processes are redundant and inefficient...... from building geometry created in Autodesk Revit and its translation to input for compliance check analysis....

  6. Development of application program and building database to increase facilities for using the radiation effect assessment computer codes

    International Nuclear Information System (INIS)

    Hyun Seok Ko; Young Min Kim; Suk-Hoon Kim; Dong Hoon Shin; Chang-Sun Kang

    2005-01-01

    The current radiation effect assessment system is required the skillful technique about the application for various code and high level of special knowledge classified by field. Therefore, as a matter of fact, it is very difficult for the radiation users' who don't have enough special knowledge to assess or recognize the radiation effect properly. For this, we already have developed the five Computer codes(windows-based), that is the radiation effect assessment system, in radiation utilizing field including the nuclear power generation. It needs the computer program that non-specialist can use the five computer codes to have already developed with ease. So, we embodied the A.I-based specialist system that can infer the assessment system by itself, according to the characteristic of given problem. The specialist program can guide users, search data, inquire of administrator directly. Conceptually, with circumstance which user to apply the five computer code may encounter actually, we embodied to consider aspects as follows. First, the accessibility of concept and data to need must be improved. Second, the acquirement of reference theory and use of corresponding computer code must be easy. Third, Q and A function needed for solution of user's question out of consideration previously. Finally, the database must be renewed continuously. Actually, to express this necessity, we develop the client program to organize reference data, to build the access methodology(query) about organized data, to load the visible expression function of searched data. And It is embodied the instruction method(effective theory acquirement procedure and methodology) to acquire the theory referring the five computer codes. It is developed the data structure access program(DBMS) to renew continuously data with ease. For Q and A function, it is embodied the Q and A board within client program because the user of client program can search the content of question and answer. (authors)

  7. Violations of the International Code of Marketing of Breast-milk Substitutes: Indonesia context.

    Science.gov (United States)

    Hidayana, Irma; Februhartanty, Judhiastuty; Parady, Vida A

    2017-01-01

    To measure compliance with the International Code of Marketing of Breast-milk Substitutes ('the Code') in Indonesia. The study was a cross-sectional survey using the Interagency Group on Breastfeeding Monitoring protocol. Public and private health facilities in six provinces on Java island in Indonesia. A total of 874 women (382 pregnant women and 492 breast-feeding mothers of infants below 6 months) and seventy-seven health workers were recruited from eighteen participating health facilities. The study also analysed a total of forty-four labels of breast-milk substitute products, twenty-seven television commercials for growing-up milk (for children >12 months) of nine brands and thirty-four print advertisements of fourteen brands. The study found that 20 % of the women had received advice and information on the use of breast-milk substitutes and 72 % had seen promotional materials for breast-milk substitutes. About 15 % reported receiving free samples and 16 % received gifts. Nearly a quarter of the health workers confirmed receiving visits from representatives of breast-milk substitute companies. Two health workers reported having received gifts from the companies. The most common labelling violations found were statements or visuals that discouraged breast-feeding and the absence of mention about the consideration of local climate in the expiration date. Violations of the Code by health workers, breast-milk substitute companies and their representatives were found in all provinces studied. A regular monitoring system should be in place to ensure improved compliance with and enforcement of the Code.

  8. Simulation of international standard problem no. 44 open tests using Melcor computer code

    International Nuclear Information System (INIS)

    Song, Y.M.; Cho, S.W.

    2001-01-01

    MELCOR 1.8.4 code has been employed to simulate the KAEVER test series of K123/K148/K186/K188 that were proposed as open experiments of International Standard Problem No.44 by OECD-CSNI. The main purpose of this study is to evaluate the accuracy of the MELCOR aerosol model which calculates the aerosol distribution and settlement in a containment. For this, thermal hydraulic conditions are simulated first for the whole test period and then the behavior of hygroscopic CsOH/CsI and unsoluble Ag aerosols, which are predominant activity carriers in a release into the containment, is compared between the experimental results and the code predictions. The calculation results of vessel atmospheric concentration show a good simulation for dry aerosol but show large difference for wet aerosol due to a data mismatch in vessel humidity and the hygroscopicity. (authors)

  9. Comparison of computer codes relative to the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

    International Nuclear Information System (INIS)

    Fermandjian, J.; Dunbar, I.; Gauvain, J.; Ricchena, R.

    1986-02-01

    The present study concerns a comparative exercise, performed within the framework of the Commission of the European Communities, of the computer codes (AEROSISM-M, UK; AEROSOLS/BI, France; CORRAL-2, CEC and NAUA Mod5, Germany) used in order to assess the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

  10. Coded Splitting Tree Protocols

    DEFF Research Database (Denmark)

    Sørensen, Jesper Hemming; Stefanovic, Cedomir; Popovski, Petar

    2013-01-01

    This paper presents a novel approach to multiple access control called coded splitting tree protocol. The approach builds on the known tree splitting protocols, code structure and successive interference cancellation (SIC). Several instances of the tree splitting protocol are initiated, each...... instance is terminated prematurely and subsequently iterated. The combined set of leaves from all the tree instances can then be viewed as a graph code, which is decodable using belief propagation. The main design problem is determining the order of splitting, which enables successful decoding as early...

  11. pix2code: Generating Code from a Graphical User Interface Screenshot

    OpenAIRE

    Beltramelli, Tony

    2017-01-01

    Transforming a graphical user interface screenshot created by a designer into computer code is a typical task conducted by a developer in order to build customized software, websites, and mobile applications. In this paper, we show that deep learning methods can be leveraged to train a model end-to-end to automatically generate code from a single input image with over 77% of accuracy for three different platforms (i.e. iOS, Android and web-based technologies).

  12. Data for occupancy internal heat gain calculation in main building categories

    Directory of Open Access Journals (Sweden)

    Kaiser Ahmed

    2017-12-01

    Full Text Available Heat losses from occupant body by means of convection, radiation, vapor, and sweat are essential data for indoor climate and energy simulations. Heat losses depend on the metabolic activity and body surface area. Higher variations of body surface area of occupants are observed in day care centers, kinder gardens and schools compared to other building categories (Tables 2 and 3 and these variations need to be accounted, otherwise in these building categories heat gains, CO2 and humidity generation are overestimated. Indoor temperature, humidity level, air velocity, and clothing insulation have significant influences on dry and total heat losses from occupant body leading to typical values for summer and winter. The data presented in this article are related to the research article entitled Occupancy schedules for energy simulation in new prEN16798-1 and ISO/FDIS 17772-1 standards (Ahmed et al., 2017 [1]. Keywords: Body surface area, Metabolic rate, Dry heat loss, Total heat loss, Internal heat gain

  13. Comparison of european computer codes relative to the aerosol behavior in PWR containment buildings during severe core damage accidents. (Modelling of steam condensation on the particles)

    International Nuclear Information System (INIS)

    Bunz, H.; Dunbar, L.H.; Fermandjian, J.; Lhiaubet, G.

    1987-11-01

    An aerosol code comparison exercise was performed within the framework of the Commission of European Communities (Division of Safety of Nuclear Installations). This exercise, focused on the process of steam condensation onto the aerosols occurring in PWR containment buildings during severe core damage accidents, has allowed to understand the discrepancies between the results obtained. These discrepancies are due, in particular, to whether the curvature effect is modelled or not in the codes

  14. The use of plane parallel ionization chambers in high energy electron and photon beams. An international code of practice for dosimetry

    International Nuclear Information System (INIS)

    1997-01-01

    Research on plane-parallel ionization chambers since the IAEA code of practice (TRS-277) was published in 1987 has explained our knowledge on perturbation and other correction factors in ionization chamber, and also constructional details of these chambers have been shown to be important. Different countries have published, or are in the process of publishing, dosimetry recommendations which include specific procedures for the use of plan parallel ionization chambers. An international working group was formed under the auspieces of the IAEA, first to review the status and the actual validity of the code of practice and second to develop an international code of practice of the use of plane parallel ionization chambers in high energy electron and photon beams used in radiotherapy. This document fulfills the second taste. 153 refs, 21 figs, 18 tabs

  15. The Aster code

    International Nuclear Information System (INIS)

    Delbecq, J.M.

    1999-01-01

    The Aster code is a 2D or 3D finite-element calculation code for structures developed by the R and D direction of Electricite de France (EdF). This dossier presents a complete overview of the characteristics and uses of the Aster code: introduction of version 4; the context of Aster (organisation of the code development, versions, systems and interfaces, development tools, quality assurance, independent validation); static mechanics (linear thermo-elasticity, Euler buckling, cables, Zarka-Casier method); non-linear mechanics (materials behaviour, big deformations, specific loads, unloading and loss of load proportionality indicators, global algorithm, contact and friction); rupture mechanics (G energy restitution level, restitution level in thermo-elasto-plasticity, 3D local energy restitution level, KI and KII stress intensity factors, calculation of limit loads for structures), specific treatments (fatigue, rupture, wear, error estimation); meshes and models (mesh generation, modeling, loads and boundary conditions, links between different modeling processes, resolution of linear systems, display of results etc..); vibration mechanics (modal and harmonic analysis, dynamics with shocks, direct transient dynamics, seismic analysis and aleatory dynamics, non-linear dynamics, dynamical sub-structuring); fluid-structure interactions (internal acoustics, mass, rigidity and damping); linear and non-linear thermal analysis; steels and metal industry (structure transformations); coupled problems (internal chaining, internal thermo-hydro-mechanical coupling, chaining with other codes); products and services. (J.S.)

  16. Relevance and Effectiveness of the WHO Global Code Practice on the International Recruitment of Health Personnel--Ethical and Systems Perspectives.

    Science.gov (United States)

    Brugha, Ruairí; Crowe, Sophie

    2015-05-20

    The relevance and effectiveness of the World Health Organization's (WHO's) Global Code of Practice on the International Recruitment of Health Personnel is being reviewed in 2015. The Code, which is a set of ethical norms and principles adopted by the World Health Assembly (WHA) in 2010, urges members states to train and retain the health personnel they need, thereby limiting demand for international migration, especially from the under-staffed health systems in low- and middle-income countries. Most countries failed to submit a first report in 2012 on implementation of the Code, including those source countries whose health systems are most under threat from the recruitment of their doctors and nurses, often to work in 4 major destination countries: the United States, United Kingdom, Canada and Australia. Political commitment by source country Ministers of Health needs to have been achieved at the May 2015 WHA to ensure better reporting by these countries on Code implementation for it to be effective. This paper uses ethics and health systems perspectives to analyse some of the drivers of international recruitment. The balance of competing ethics principles, which are contained in the Code's articles, reflects a tension that was evident during the drafting of the Code between 2007 and 2010. In 2007-2008, the right of health personnel to migrate was seen as a preeminent principle by US representatives on the Global Council which co-drafted the Code. Consensus on how to balance competing ethical principles--giving due recognition on the one hand to the obligations of health workers to the countries that trained them and the need for distributive justice given the global inequities of health workforce distribution in relation to need, and the right to migrate on the other hand--was only possible after President Obama took office in January 2009. It is in the interests of all countries to implement the Global Code and not just those that are losing their health

  17. Modernising ATLAS Software Build Infrastructure

    CERN Document Server

    Ritsch, Elmar; The ATLAS collaboration

    2017-01-01

    In the last year ATLAS has radically updated its software development infrastructure hugely reducing the complexity of building releases and greatly improving build speed, flexibility and code testing. The first step in this transition was the adoption of CMake as the software build system over the older CMT. This required the development of an automated translation from the old system to the new, followed by extensive testing and improvements. This resulted in a far more standard build process that was married to the method of building ATLAS software as a series of $12$ separate projects from Subversion. We then proceeded with a migration of the code base from Subversion to Git. As the Subversion repository had been structured to manage each package more or less independently there was no simple mapping that could be used to manage the migration into Git. Instead a specialist set of scripts that captured the software changes across official software releases was developed. With some clean up of the repositor...

  18. SEISMIC EVALUATION OF EXISTING MID-RISE REINFORCED CONCRETE BUILDINGS ACCORDING TO SPECIFICATION FOR BUILDING STRUCTURES TO BE BUILT IN DISASTER AREAS

    Directory of Open Access Journals (Sweden)

    Mehmet İNEL

    2007-01-01

    Full Text Available Over the past several decades, Turkey has been hit by devastating earthquakes and remarkable number of reinforced concrete buildings has been damaged in the high seismicity regions of our country. The aim of this study is to evaluate the seismic performance of the mid-rise reinforced concrete buildings that are major part of building stock of our earthquake-prone country, according to recent Turkish Earthquake Code. 4- and 7-story buildings were selected to represent mid-rise building stock. After determining the structural parameters, each building was subjected to pushover analysis and the capacity curves were obtained. Earthquake performance of each building was determined in the light of their capacity curves according to the recent Turkish Earthquake Code.

  19. Monitoring compliance with the International Code of Marketing of Breastmilk Substitutes in west Africa: multisite cross sectional survey in Togo and Burkina Faso.

    Science.gov (United States)

    Aguayo, Victor M; Ross, Jay S; Kanon, Souleyman; Ouedraogo, Andre N

    2003-01-18

    To monitor compliance with the International Code of Marketing of Breastmilk Substitutes in health systems, sales outlets, distribution points, and the news media in Togo and Burkina Faso, west Africa. Multisite cross sectional survey. Staff at 43 health facilities and 66 sales outlets and distribution points, 186 health providers, and 105 mothers of infants aged market commercial breast milk substitutes were found in 29 (44%) sales and distribution points. Forty commercial breast milk substitutes violated the labelling standards of the code: 21 were manufactured by Danone, 11 by Nestlé, and eight by other national and international manufacturers. Most (148, 90%) health providers had never heard of the code, and 66 mothers (63%) had never received any counselling on breast feeding by their health providers. In west Africa manufacturers are violating the code of marketing of breast milk substitutes. Comparable levels of code violations are observed with (Burkina Faso) or without (Togo) regulating legislation. Legislation must be accompanied by effective information, training, and monitoring systems to ensure that healthcare providers and manufacturers comply with evidence based practice and the code.

  20. Coding Theory, Cryptography and Related Areas

    DEFF Research Database (Denmark)

    Buchmann, Johannes; Stichtenoth, Henning; Tapia-Recillas, Horacio

    Proceedings of anInternational Conference on Coding Theory, Cryptography and Related Areas, held in Guanajuato, Mexico. in april 1998......Proceedings of anInternational Conference on Coding Theory, Cryptography and Related Areas, held in Guanajuato, Mexico. in april 1998...

  1. International Conference on Human Resource Development for Nuclear Power Programmes: Building and Sustaining Capacity. Presentations

    International Nuclear Information System (INIS)

    2014-01-01

    The objectives of the conference are to: • Review developments in the global status of HRD since the 2010 international conference; • Emphasize the role of human resources and capacity building programmes at the national and organizational level for achieving safe, secure and sustainable nuclear power programmes; • Discuss the importance of building competence in nuclear safety and security; • Provide a forum for information exchange on national, as well as international, policies and practices; • Share key elements and best practices related to the experience of Member States that are introducing, operating or expanding nuclear power programmes; • Highlight the practices and issues regarding HRD at the organizational and national level; • Highlight education and training programmes and practices; • Emphasize the role of nuclear knowledge management for knowledge transfer and HRD; and • Elaborate on the role and scope of various knowledge networks

  2. Wood: a construction material for tall buildings

    Science.gov (United States)

    Wimmers, Guido

    2017-12-01

    Wood has great potential as a building material, because it is strong and lightweight, environmentally friendly and can be used in prefabricated buildings. However, only changes in building codes will make wood competitive with steel and concrete.

  3. A Buildings Module for the Stochastic Energy Deployment System

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Marnay, Chris; Stadler, Michael; Borgeson, Sam; Coffey, Brian; Komiyama, Ryoichi; Lai, Judy

    2008-05-15

    The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

  4. SOME CONSIDERATIONS REGARDING THE AD-HOC INTERNAL ARBITRATION PROCEDURE IN THE NEW CODE OF CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Daniela Cristina Creţ

    2013-12-01

    Full Text Available One of the institutions to have undergone essential changes as a result of the 2013 entry into force of the New Code of civil procedure is arbitration. Arbitration is an alternative way of settling conflicts by means of a specialized person or institution, based on the will of the parties or on an international convention. This article will present a few introductory aspects that are essential for a foray into the field, as well as analyze the main aspects of arbitral procedure from the perspective of novelties and changes brought to the provisions of the New Code of civil procedure (hereinafter referred to as N.C.C.P..

  5. Concorde noise-induced building vibrations: International Airport Dulles. [studies by Langley Research Center

    Science.gov (United States)

    Mayes, W. H.; Scholl, H. F.; Stephens, D. G.; Holliday, B. G.; Deloach, R.; Finley, T. D.; Holmes, H. K.; Lewis, R. B.; Lynch, J. W.

    1977-01-01

    A series of studies were conducted to assess the noise-induced building vibrations associated with Concorde operations. The vibration levels of windows, walls, and floors were measured along with the associated noise levels of Concorde, subsonic aircraft and some nonaircraft events. Test sites included Sully Plantation which is adjacent to Dulles International Airport and three residential homes located in Montgomery County, Maryland. The measured vibration response levels due to Concorde operations were found to be: (1) higher than the levels due to other aircraft, (2) less than the levels due to certain household events which involve direct impulsive loading such as door and window closing, (3) less than criteria levels for building damage, and (4) comparable to levels which are perceptible to people.

  6. EFFECTS OF COLUMN FAILURES ON THE INTERNAL FORCES OF ORTHOGONAL REINFORCED CONCRETE BUILDING FRAMES

    Directory of Open Access Journals (Sweden)

    Nilay KAYA

    2006-02-01

    Full Text Available In this study, the effects of column failures which may take place due to the special causes such as blast, vehicle impact, insufficient or deficient design, on the internal forces of orthogonal reinforced concrete building frames have been investigated. Calculations have been performed with SAP2000 structural analysis program, under static conditions. For a typical frame system, firstly, various column failure scenarios have been considered for uninfilled case and internal forces have been calculated and compared with those in the intact case. Then, similar calculations have been implemented for the case of presence of infill walls. The results of analyses have shown that the effects of column failures had condensed on the neighbor columns and beams of orthogonal frames on which the columns had been failed. Moreover, it has been determined that, while the bending moment capacities of the connected beams to the failed columns had exceeded in the bare frames, in the masonry infilled frames, walls give substantial support to the structural elements of the building, and capacities of the beams had not exceeded.

  7. Transition to international classification of disease version 10, clinical modification: the impact on internal medicine and internal medicine subspecialties.

    Science.gov (United States)

    Caskey, Rachel N; Abutahoun, Angelos; Polick, Anne; Barnes, Michelle; Srivastava, Pavan; Boyd, Andrew D

    2018-05-04

    The US health care system uses diagnostic codes for billing and reimbursement as well as quality assessment and measuring clinical outcomes. The US transitioned to the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) on October, 2015. Little is known about the impact of ICD-10-CM on internal medicine and medicine subspecialists. We used a state-wide data set from Illinois Medicaid specified for Internal Medicine providers and subspecialists. A total of 3191 ICD-9-CM codes were used for 51,078 patient encounters, for a total cost of US $26,022,022 for all internal medicine. We categorized all of the ICD-9-CM codes based on the complexity of mapping to ICD-10-CM as codes with complex mapping could result in billing or administrative errors during the transition. Codes found to have complex mapping and frequently used codes (n = 295) were analyzed for clinical accuracy of mapping to ICD-10-CM. Each subspecialty was analyzed for complexity of codes used and proportion of reimbursement associated with complex codes. Twenty-five percent of internal medicine codes have convoluted mapping to ICD-10-CM, which represent 22% of Illinois Medicaid patients, and 30% of reimbursements. Rheumatology and Endocrinology had the greatest proportion of visits and reimbursement associated with complex codes. We found 14.5% of ICD-9-CM codes used by internists, when mapped to ICD-10-CM, resulted in potential clinical inaccuracies. We identified that 43% of diagnostic codes evaluated and used by internists and that account for 14% of internal medicine reimbursements are associated with codes which could result in administrative errors.

  8. Canadian energy standards : residential energy code requirements

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, K. [SAR Engineering Ltd., Burnaby, BC (Canada)

    2006-09-15

    A survey of residential energy code requirements was discussed. New housing is approximately 13 per cent more efficient than housing built 15 years ago, and more stringent energy efficiency requirements in building codes have contributed to decreased energy use and greenhouse gas (GHG) emissions. However, a survey of residential energy codes across Canada has determined that explicit demands for energy efficiency are currently only present in British Columbia (BC), Manitoba, Ontario and Quebec. The survey evaluated more than 4300 single-detached homes built between 2000 and 2005 using data from the EnerGuide for Houses (EGH) database. House area, volume, airtightness and construction characteristics were reviewed to create archetypes for 8 geographic areas. The survey indicated that in Quebec and the Maritimes, 90 per cent of houses comply with ventilation system requirements of the National Building Code, while compliance in the rest of Canada is much lower. Heat recovery ventilation use is predominant in the Atlantic provinces. Direct-vent or condensing furnaces constitute the majority of installed systems in provinces where natural gas is the primary space heating fuel. Details of Insulation levels for walls, double-glazed windows, and building code insulation standards were also reviewed. It was concluded that if R-2000 levels of energy efficiency were applied, total average energy consumption would be reduced by 36 per cent in Canada. 2 tabs.

  9. Validity of International Classification of Diseases (ICD) coding for dengue infections in hospital discharge records in Malaysia.

    Science.gov (United States)

    Woon, Yuan-Liang; Lee, Keng-Yee; Mohd Anuar, Siti Fatimah Zahra; Goh, Pik-Pin; Lim, Teck-Onn

    2018-04-20

    Hospitalization due to dengue illness is an important measure of dengue morbidity. However, limited studies are based on administrative database because the validity of the diagnosis codes is unknown. We validated the International Classification of Diseases, 10th revision (ICD) diagnosis coding for dengue infections in the Malaysian Ministry of Health's (MOH) hospital discharge database. This validation study involves retrospective review of available hospital discharge records and hand-search medical records for years 2010 and 2013. We randomly selected 3219 hospital discharge records coded with dengue and non-dengue infections as their discharge diagnoses from the national hospital discharge database. We then randomly sampled 216 and 144 records for patients with and without codes for dengue respectively, in keeping with their relative frequency in the MOH database, for chart review. The ICD codes for dengue were validated against lab-based diagnostic standard (NS1 or IgM). The ICD-10-CM codes for dengue had a sensitivity of 94%, modest specificity of 83%, positive predictive value of 87% and negative predictive value 92%. These results were stable between 2010 and 2013. However, its specificity decreased substantially when patients manifested with bleeding or low platelet count. The diagnostic performance of the ICD codes for dengue in the MOH's hospital discharge database is adequate for use in health services research on dengue.

  10. Relative political and value proximity in mediated public diplomacy: The effect of state-level homophily on international frame building

    NARCIS (Netherlands)

    Sheafer, T.; Shenhav, S.R.; Takens, J.H.; van Atteveldt, W.H.

    2014-01-01

    This article applies the homophily thesis to public diplomacy and offers an empirical examination of a country's success in its mediated public diplomacy efforts. It analyzes international frame building, the process of creating or changing media frames in the international communications arena, by

  11. Code of Practice on the International Transboundary Movement of Radioactive Waste; Kodeks Praktiki V Oblasti Meikduiarodnog0 Transgranichnogo Peremeshhenija Radioaktivnyh Othodov

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-15

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States [Russian] 21 sentjabrja 1990 goda General'naja konferencija prinjala rezoljuciju GC(XXXIV)/RES/530 o Kodekse praktiki v oblasti mezhdunarodnogo transgranichnogo peremeshhenija radioaktivnyh othodov i predlozhila General'nomu direktoru , v chastnosti, prinjat' vse neobhodimye mery dlja obespechenija shirokogo rasprostranenija Kodeksa praktiki kak na nacional'nom, tak i na mezhdunarodnom urovnjah. Kodeks praktiki byl podgotovlen gruppoj jekspertov , uchrezhdennoj vo ispolnenie rezoljucii GC(XXXII)/RES/490, prinjatoj General'noj konferenciej v 1988 godu. Tekst Kodeksa praktiki vosproizvoditsja nizhe dlja informacii vseh gosudarstv-chlenov.

  12. Comparison Of Seismic Performance Of Erciş Cultural Center Building With Observed And Calculated By Turkish Earthquake Code-2007

    Directory of Open Access Journals (Sweden)

    Recep Ali Dedecan

    2013-08-01

    Full Text Available The goal of this paper is to review the validity of seismic assessment procedure given in the Turkish Earthquake Code by comparing the assessment results with real structures from Eastern Turkey, where the 2011 Van earthquake occurred. To test the analysis methods for a typically suitable structure, the cultural center building at Erciş with 3 stories, is selected. In order to compare the results of the three different analysis techniques, for an identical earthquake, the ground motion used in analysis was characterized by equivalent elastic earthquake spectra, which were developed from available time history at the nearest construction site. It was found that the damage predictions by using the by Turkish Earthquake Code procedures point out the different level of damages. But, it is concluded that nonlinear time history analysis calculated the best estimation of the damage observed in the site.

  13. 78 FR 69839 - Building Technologies Office Prioritization Tool

    Science.gov (United States)

    2013-11-21

    ... standards and building codes to ensure energy savings within buildings. BTO has developed a new technology... DEPARTMENT OF ENERGY Building Technologies Office Prioritization Tool AGENCY: Office of Energy....S. Department of Energy's (DOE) Building Technologies Office (BTO) developed the Prioritization Tool...

  14. "Watts per person" paradigm to design net zero energy buildings: Examining technology interventions and integrating occupant feedback to reduce plug loads in a commercial building

    Science.gov (United States)

    Yagi Kim, Mika

    As building envelopes have improved due to more restrictive energy codes, internal loads have increased largely due to the proliferation of computers, electronics, appliances, imaging and audio visual equipment that continues to grow in commercial buildings. As the dependency on the internet for information and data transfer increases, the electricity demand will pose a challenge to design and operate Net Zero Energy Buildings (NZEBs). Plug Loads (PLs) as a proportion of the building load has become the largest non-regulated building energy load and represents the third highest electricity end-use in California's commercial office buildings, accounting for 23% of the total building electricity consumption (Ecova 2011,2). In the Annual Energy Outlook 2008 (AEO2008), prepared by the Energy Information Administration (EIA) that presents long-term projections of energy supply and demand through 2030 states that office equipment and personal computers are the "fastest growing electrical end uses" in the commercial sector. This thesis entitled "Watts Per Person" Paradigm to Design Net Zero Energy Buildings, measures the implementation of advanced controls and behavioral interventions to study the reduction of PL energy use in the commercial sector. By integrating real world data extracted from an energy efficient commercial building of its energy use, the results produce a new methodology on estimating PL energy use by calculating based on "Watts Per Person" and analyzes computational simulation methods to design NZEBs.

  15. Milk and social media: online communities and the International Code of Marketing of Breast-milk Substitutes.

    Science.gov (United States)

    Abrahams, Sheryl W

    2012-08-01

    The advent of social networking sites and other online communities presents new opportunities and challenges for the promotion, protection, and support of breastfeeding. This study examines the presence of infant formula marketing on popular US social media sites, using the World Health Organization International Code of Marketing of Breast-milk Substitutes (the Code) as a framework. We examined to what extent each of 11 infant formula brands that are widely available in the US had established a social media presence in popular social media venues likely to be visited by expectant parents and families with young children. We then examined current marketing practices, using the Code as a basis for ethical marketing. Infant formula manufacturers have established a social media presence primarily through Facebook pages, interactive features on their own Web sites, mobile apps for new and expecting parents, YouTube videos, sponsored reviews on parenting blogs, and other financial relationships with parenting blogs. Violations of the Code as well as promotional practices unforeseen by the Code were identified. These practices included enabling user-generated content that promotes the use of infant formula, financial relationships between manufacturers and bloggers, and creation of mobile apps for use by parents. An additional concern identified for Code enforcement is lack of transparency in social media-based marketing. The use of social media for formula marketing may demand new strategies for monitoring and enforcing the Code in light of emerging challenges, including suggested content for upcoming consideration for World Health Assembly resolutions.

  16. A Methodology to Link the Internal Heat Gains from Lighting to the Global Consumption for the Energy Certification of Buildings in Italy

    Directory of Open Access Journals (Sweden)

    Valerio R.M. Lo Verso

    2014-12-01

    Full Text Available This paper critically discusses the procedure prescribed by the Italian Technical Standards to account for the internal gains in the calculation of the energy performance indices for a building. This procedure is based on a tabular value set depending on the building usage only (e.g., 6 W/m2 for office buildings, independently of the site and of the controls for blinds and lighting systems. Instead, the paper proposes a new procedure, which relies on the lighting energy numerical indicator (LENI according to the European Standard EN 15193:2007. Basically, the procedure consists of the following steps: 1 internal gains from lighting are calculated accounting for the integration between electric appliances and daylighting; 2 these gains are summed to the internal gains from occupants and appliances; 3 the global gains are used as input data to calculate the energy performance indices for an office building (for space heating, space cooling, and lighting consumption following the Italian Technical Standards. The office building which was used as case-study is the Department of Energy of the Politecnico di Torino. This was assumed to be located both in Turin (northern Italy and in Palermo (southern Italy. In the study, the use of a manual on/off switch and of a photodimming sensor was also compared. For each configuration, the single and the global energy performance indices were calculated comparing two approaches to calculate the internal gains (Italian standard vs. new proposed procedure: a shift of one energy class for the building energy label was observed depending on the approach, which was used.

  17. Comparison of Building Energy Modeling Programs: Building Loads

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Dandan [Tsinghua Univ., Beijing (China); Hong, Tianzhen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yan, Da [Tsinghua Univ., Beijing (China); Wang, Chuang [Tsinghua Univ., Beijing (China)

    2012-06-01

    This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to

  18. A SciCode web site: building bridges between owners and users

    Energy Technology Data Exchange (ETDEWEB)

    Gaver, C. [Atomic Energy of Canada Ltd., Mississauga, Ontario (Canada)

    2000-07-01

    Web technology is a tool that is gaining in popularity. Properly used, it is a powerful tool that has tremendous potential for providing better communication. It can also be effective as a training tool, an information-sharing tool, and as a means of simplifying work load, and facilitating compliance with Company procedures. The issue is one of communication. The challenge facing many large or geographically-distributed companies is how to communicate information to their staff and to their customers. Procedures overseeing quality-assurance programs and commitment to ensuring the quality of products need to be communicated to customers. Equally important is customer feedback. This information from users becomes the kernel for future product development. The issue is even more important when speaking of scientific analysis computer programs (SciCodes). Regular ongoing communication between Primary Holders and End Users is essential in the development and use of SciCodes. Without this communication, quality assurance is at risk. Quality assurance processes are an integral part in developing any SciCode. End Users also have a role to play. Primary Holders keep End Users informed of improvements or new releases. End Users must ensure they act on this information. Equally important, End Users must communicate problems or suggestions to the Primary Holder to remedy or incorporate in new releases. In other words, quality assurance processes become most effective when both Primary Holder and End Users are involved. This requires communication. Web technology offers AECL a means of providing regular, ongoing communication between its scientific-code (SciCode) Primary Holders-Owner Branches and the End Users of these codes within and outside the Company. Using the experience we have gained by developing the Y2K SciCode Web sites, setting up online documentation systems, and incorporating lessons learned from the Y2K project we have developed a model that is geared to

  19. A SciCode web site: building bridges between owners and users

    International Nuclear Information System (INIS)

    Gaver, C.

    2000-01-01

    Web technology is a tool that is gaining in popularity. Properly used, it is a powerful tool that has tremendous potential for providing better communication. It can also be effective as a training tool, an information-sharing tool, and as a means of simplifying work load, and facilitating compliance with Company procedures. The issue is one of communication. The challenge facing many large or geographically-distributed companies is how to communicate information to their staff and to their customers. Procedures overseeing quality-assurance programs and commitment to ensuring the quality of products need to be communicated to customers. Equally important is customer feedback. This information from users becomes the kernel for future product development. The issue is even more important when speaking of scientific analysis computer programs (SciCodes). Regular ongoing communication between Primary Holders and End Users is essential in the development and use of SciCodes. Without this communication, quality assurance is at risk. Quality assurance processes are an integral part in developing any SciCode. End Users also have a role to play. Primary Holders keep End Users informed of improvements or new releases. End Users must ensure they act on this information. Equally important, End Users must communicate problems or suggestions to the Primary Holder to remedy or incorporate in new releases. In other words, quality assurance processes become most effective when both Primary Holder and End Users are involved. This requires communication. Web technology offers AECL a means of providing regular, ongoing communication between its scientific-code (SciCode) Primary Holders-Owner Branches and the End Users of these codes within and outside the Company. Using the experience we have gained by developing the Y2K SciCode Web sites, setting up online documentation systems, and incorporating lessons learned from the Y2K project we have developed a model that is geared to

  20. Achieving sustainable buildings: the role of heating, ventilation and air-conditioning

    Directory of Open Access Journals (Sweden)

    Chaudhry Hassam Nasarullah

    2016-01-01

    Full Text Available With the ever-increasing population and global economy, the dependency on usage of non-renewable resources of energy is cumulating in direct proportion. Nevertheless, the non-renewable potential of these resources is certainly a leading worldwide issue, and one, which has gained substantial international interest over the past decades. Large and attractive opportunities exist to reduce building's energy use at lower costs and higher returns than other sectors. At the same time, substantial investments will be required to achieve this target as outlined by the Paris Agreement. These will require the combination of social, economic and environmental actions, including building energy codes, investment subsidies, labelling and reporting mechanisms, increased and trained workforce capacity, and evolving energy-efficient designs and HVAC technologies.

  1. Error-correction coding for digital communications

    Science.gov (United States)

    Clark, G. C., Jr.; Cain, J. B.

    This book is written for the design engineer who must build the coding and decoding equipment and for the communication system engineer who must incorporate this equipment into a system. It is also suitable as a senior-level or first-year graduate text for an introductory one-semester course in coding theory. Fundamental concepts of coding are discussed along with group codes, taking into account basic principles, practical constraints, performance computations, coding bounds, generalized parity check codes, polynomial codes, and important classes of group codes. Other topics explored are related to simple nonalgebraic decoding techniques for group codes, soft decision decoding of block codes, algebraic techniques for multiple error correction, the convolutional code structure and Viterbi decoding, syndrome decoding techniques, and sequential decoding techniques. System applications are also considered, giving attention to concatenated codes, coding for the white Gaussian noise channel, interleaver structures for coded systems, and coding for burst noise channels.

  2. Nomenclature for congenital and paediatric cardiac disease: the International Paediatric and Congenital Cardiac Code (IPCCC) and the Eleventh Iteration of the International Classification of Diseases (ICD-11).

    Science.gov (United States)

    Franklin, Rodney C G; Béland, Marie J; Colan, Steven D; Walters, Henry L; Aiello, Vera D; Anderson, Robert H; Bailliard, Frédérique; Boris, Jeffrey R; Cohen, Meryl S; Gaynor, J William; Guleserian, Kristine J; Houyel, Lucile; Jacobs, Marshall L; Juraszek, Amy L; Krogmann, Otto N; Kurosawa, Hiromi; Lopez, Leo; Maruszewski, Bohdan J; St Louis, James D; Seslar, Stephen P; Srivastava, Shubhika; Stellin, Giovanni; Tchervenkov, Christo I; Weinberg, Paul M; Jacobs, Jeffrey P

    2017-12-01

    An internationally approved and globally used classification scheme for the diagnosis of CHD has long been sought. The International Paediatric and Congenital Cardiac Code (IPCCC), which was produced and has been maintained by the International Society for Nomenclature of Paediatric and Congenital Heart Disease (the International Nomenclature Society), is used widely, but has spawned many "short list" versions that differ in content depending on the user. Thus, efforts to have a uniform identification of patients with CHD using a single up-to-date and coordinated nomenclature system continue to be thwarted, even if a common nomenclature has been used as a basis for composing various "short lists". In an attempt to solve this problem, the International Nomenclature Society has linked its efforts with those of the World Health Organization to obtain a globally accepted nomenclature tree for CHD within the 11th iteration of the International Classification of Diseases (ICD-11). The International Nomenclature Society has submitted a hierarchical nomenclature tree for CHD to the World Health Organization that is expected to serve increasingly as the "short list" for all communities interested in coding for congenital cardiology. This article reviews the history of the International Classification of Diseases and of the IPCCC, and outlines the process used in developing the ICD-11 congenital cardiac disease diagnostic list and the definitions for each term on the list. An overview of the content of the congenital heart anomaly section of the Foundation Component of ICD-11, published herein in its entirety, is also included. Future plans for the International Nomenclature Society include linking again with the World Health Organization to tackle procedural nomenclature as it relates to cardiac malformations. By doing so, the Society will continue its role in standardising nomenclature for CHD across the globe, thereby promoting research and better outcomes for fetuses

  3. Contribution of International and Regional Networks in Developing and Maintaining Human Capacity Building for Nuclear Power Programmes

    International Nuclear Information System (INIS)

    Osman, O. E.

    2015-01-01

    Capacity is defined as; the ability of individuals and organizations or organizational units to perform functions effectively, efficiently and sustainably. Capacity building is an evidence-driven process of strengthening the abilities of individuals, organizations, and systems to perform core functions sustainably, and to continue to improve and develop over time. This article will explain the contributions of knowledge networks at the national, regional and international level in developing the existing capacity building and human resources for regulatory body in Sudan, to confront the future challenges regarding to nuclear power program- safety and security. The article will compare the advantages and effectiveness of these knowledge networks (IAEA, ANNuR, FNRBA) in capacity building and enhance the infrastructure of national regulatory body. And how these networks contribute to enable the regulatory bodies in Africa and Arab countries, to establish and strengthen their regulatory infrastructure for nuclear power programme consistent with international standards and recommendations. As well as the recommendations resulting and deduced from comparative study to promote the exchange of knowledge, experience and information among its members. (author)

  4. RESRAD-BUILD: A computer model for analyzing the radiological doses resulting from the remediation and occupancy of buildings contaminated with radioactive material

    International Nuclear Information System (INIS)

    Yu, C.; LePoire, D.J.; Jones, L.G.

    1994-11-01

    The RESRAD-BUILD computer code is a pathway analysis model designed to evaluate the potential radiological dose incurred by an individual who works or lives in a building contaminated with radioactive material. The transport of radioactive material inside the building from one compartment to another is calculated with an indoor air quality model. The air quality model considers the transport of radioactive dust particulates and radon progeny due to air exchange, deposition and resuspension, and radioactive decay and ingrowth. A single run of the RESRAD-BUILD code can model a building with up to: three compartments, 10 distinct source geometries, and 10 receptor locations. A shielding material can be specified between each source-receptor pair for external gamma dose calculations. Six exposure pathways are considered in the RESRAD-BUILD code: (1) external exposure directly from the source; (2) external exposure to materials deposited on the floor; (3) external exposure due to air submersion; (4) inhalation of airborne radioactive particulates; (5) inhalation of aerosol indoor radon progeny; and (6) inadvertent ingestion of radioactive material, either directly from the sources or from materials deposited on the surfaces of the building compartments

  5. Code of Practice containing definitions for Safety Codes of Practice for nuclear power plants

    International Nuclear Information System (INIS)

    1979-01-01

    This Code provides definitions of the technical terms used in the licensing applications to be submitted to the Turkish Atomic Energy Commission (TAEC), in accordance with national licensing regulations. The Code is based mainly on the International Atomic Energy Agency's Code of Practice on the subject. (NEA) [fr

  6. Teaching & Learning for International Students in a 'Learning Community': Creating, Sharing and Building Knowledge

    Directory of Open Access Journals (Sweden)

    Linzi Kemp, PhD

    2010-08-01

    Full Text Available This article considers the culture of learning communities for effective teaching. A learning community is defined here as an environment where learners are brought together to share information, to learn from each other, and to create new knowledge. The individual student develops her/his own learning by building on learning from others. In a learning community approach to teaching, educators can ensure that students gain workplace skills such as collaboration, creativity, critical thinking, and problem solving. In this case study, it is shown how an active learning community, introduced into a blended teaching environment (face-to-face and virtual, effectively supported international undergraduates in the building of knowledge and workplace skills.

  7. Modernising ATLAS Software Build Infrastructure

    CERN Document Server

    Gaycken, Goetz; The ATLAS collaboration

    2017-01-01

    In the last year ATLAS has radically updated its software development infrastructure hugely reducing the complexity of building releases and greatly improving build speed, flexibility and code testing. The first step in this transition was the adoption of CMake as the software build system over the older CMT. This required the development of an automated translation from the old system to the new, followed by extensive testing and improvements. This resulted in a far more standard build process that was married to the method of building ATLAS software as a series of 12 separate projects from SVN. We then proceeded with a migration of its code base from SVN to git. As the SVN repository had been structured to manage each package more or less independently there was no simple mapping that could be used to manage the migration into git. Instead a specialist set of scripts that captured the software changes across official software releases was developed. With some clean up of the repository and the policy of onl...

  8. Programming Entity Framework Code First

    CERN Document Server

    Lerman, Julia

    2011-01-01

    Take advantage of the Code First data modeling approach in ADO.NET Entity Framework, and learn how to build and configure a model based on existing classes in your business domain. With this concise book, you'll work hands-on with examples to learn how Code First can create an in-memory model and database by default, and how you can exert more control over the model through further configuration. Code First provides an alternative to the database first and model first approaches to the Entity Data Model. Learn the benefits of defining your model with code, whether you're working with an exis

  9. City Reach Code Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Frankel, Mark [New Buildings Inst., Portland, OR (United States); Lyles, Mark [New Buildings Inst., Portland, OR (United States)

    2017-10-31

    This report describes and analyzes a set of energy efficiency measures that will save 20% energy over ASHRAE Standard 90.1-2013. The measures will be used to formulate a Reach Code for cities aiming to go beyond national model energy codes. A coalition of U.S. cities together with other stakeholders wanted to facilitate the development of voluntary guidelines and standards that can be implemented in stages at the city level to improve building energy efficiency. The coalition's efforts are being supported by the U.S. Department of Energy via Pacific Northwest National Laboratory (PNNL) and in collaboration with the New Buildings Institute.

  10. Neutron Fluence Evaluation of Reactor Internal Structure Using 3D Transport Calculation Code, RAPTOR-M3G

    International Nuclear Information System (INIS)

    Maeng, YoungJae; Lim, MiJoung; Kim, KyungSik; Cho, YoungKi; Yoo, ChoonSung; Kim, ByoungChul

    2015-01-01

    Age-related degradation mechanisms are including the irradiation-assisted stress corrosion cracking(IASCC), void swelling, stress relaxation, fatigue, and etc. A lot of Baffle Former Bolts(BFBs) was installed at the former plate ends between baffle and barrel structure. These would undergo severe experiences, which are high temperature and pressure, bypass water flow and neutron exposure and have some radioactive limitation in inspecting their integrity. The objectives of this paper is to evaluate fast neutron fluence(n/cm 2 , E>1.0MeV) for PWR internals using 3D transport calculation code, RAPTOR-M3G, and to figure out a strategy to manage the effects of aging in PWR internals. One of age-related degradation mechanisms, IASCC, which is affected by fast neutron exposure rate, has been currently issued for PWR internals and has 2 x 10 21 (n/cm 2 ) of the threshold value by MRP-175. Because a lot of BFBs was installed around the internal components, closer inspections are required. As part of an aging management for Kori unit 2, 3D transport calculation code, RAPTOR-M3G, was applied for determining fast neutron fluence at baffle, barrel and former plates regions. As a result, the fast neutron fluence exceeds the screening or threshold values of IASCC in all of baffle, barrel and former plate region. And the most significant region is the baffle because it is located closest to the core. In addition, some regions including former plate tend to be more damaged because of less moderate ability than water. In conclusion, Ice's has been progressed for PWR internals of Kori unit 2. Several regions of internal components were damaged by fast neutron exposure and increase in size as time goes by

  11. Strategies for Sustainable Comfort in Buildings

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1997-01-01

    these goals include phasing out all use of electricity for space heating and for hot water supply. Furthermore building codes should require new buildings to be very well insulated, 30-40 cm mineral wool, for instance, and low energy windows. Similar codes, although not always as strict, should be applied......It is possible within some decades to achieve environmental sustainability in the building sector and at the same time provide a comfortable and healthy life for all Europeans as well as leaving that option open for other people in the world.Buildings are charcterized by having the longest lifetime...... of all capital in our societies, often more than a hundred years. For that reason they should never be designed on the bases of just present cheap energy supply and energy system, but with the long term outlook and risks in mind. New buildings can be designed to require essentially no space heating...

  12. Rise of the build infrastructure

    International Nuclear Information System (INIS)

    Eulisse, Giulio; Muzaffar, Shahzad; Abdurachmanov, David; Mendez, David

    2014-01-01

    CMS Offline Software, CMSSW, is an extremely large software project, with roughly 3 millions lines of code, two hundreds of active developers and two to three active development branches. Given the scale of the problem, both from a technical and a human point of view, being able to keep on track such a large project, bug free, and to deliver builds for different architectures is a challenge in itself. Moreover the challenges posed by the future migration of CMSSW to multithreading also require adapting and improving our QA tools. We present the work done in the last two years in our build and integration infrastructure, particularly in the form of improvements to our build tools, in the simplification and extensibility of our build infrastructure and the new features added to our QA and profiling tools. Finally we present our plans for the future directions for code management and how this reflects on our workflows and the underlying software infrastructure.

  13. High dynamic range coding imaging system

    Science.gov (United States)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  14. Fire flow water consumption in sprinklered and unsprinklered buildings an assessment of community impacts

    CERN Document Server

    Code Consultants, Inc.

    2012-01-01

    Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage. The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Cons...

  15. You know the Science. Do you know your Code?

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    This talk is about automated code analysis and transformation tools to support scientific computing. Code bases are difficult to manage because of size, age, or safety requirements. Tools can help scientists and IT engineers understand their code, locate problems, improve quality. Tools can also help transform the code, by implementing complex refactorings, replatforming, or migration to a modern language. Such tools are themselves difficult to build. This talk describes DMS, a meta-tool for building software analysis tools. DMS is a kind of generalized compiler, and can be configured to process arbitrary programming languages, to carry out arbitrary analyses, and to convert specifications into running code. It has been used for a variety of purposes, including converting embedded mission software in the US B-2 Stealth Bomber, providing the US Social Security Administration with a deep view how their 200 millions lines of COBOL are connected, and reverse-engineering legacy factory process control code i...

  16. Reliability of cause of death coding: an international comparison.

    Science.gov (United States)

    Antini, Carmen; Rajs, Danuta; Muñoz-Quezada, María Teresa; Mondaca, Boris Andrés Lucero; Heiss, Gerardo

    2015-07-01

    This study evaluates the agreement of nosologic coding of cardiovascular causes of death between a Chilean coder and one in the United States, in a stratified random sample of death certificates of persons aged ≥ 60, issued in 2008 in the Valparaíso and Metropolitan regions, Chile. All causes of death were converted to ICD-10 codes in parallel by both coders. Concordance was analyzed with inter-coder agreement and Cohen's kappa coefficient by level of specification ICD-10 code for the underlying cause and the total causes of death coding. Inter-coder agreement was 76.4% for all causes of death and 80.6% for the underlying cause (agreement at the four-digit level), with differences by the level of specification of the ICD-10 code, by line of the death certificate, and by number of causes of death per certificate. Cohen's kappa coefficient was 0.76 (95%CI: 0.68-0.84) for the underlying cause and 0.75 (95%CI: 0.74-0.77) for the total causes of death. In conclusion, causes of death coding and inter-coder agreement for cardiovascular diseases in two regions of Chile are comparable to an external benchmark and with reports from other countries.

  17. Building energy efficiency in rural China

    International Nuclear Information System (INIS)

    Evans, Meredydd; Yu, Sha; Song, Bo; Deng, Qinqin; Liu, Jing; Delgado, Alison

    2014-01-01

    Rural buildings in China now account for more than half of China's total building energy use. Forty percent of the floorspace in China is in rural villages and towns. Most of these buildings are very energy inefficient, and may struggle to provide for basic needs. They are cold in the winter, and often experience indoor air pollution from fuel use. The Chinese government plans to adopt a voluntary building energy code, or design standard, for rural homes. The goal is to build on China's success with codes in urban areas to improve efficiency and comfort in rural homes. The Chinese government recognizes rural buildings represent a major opportunity for improving national building energy efficiency. The challenges of rural China are also greater than those of urban areas in many ways because of the limited local capacity and low income levels. The Chinese government wants to expand on new programs to subsidize energy efficiency improvements in rural homes to build capacity for larger-scale improvement. This article summarizes the trends and status of rural building energy use in China. It then provides an overview of the new rural building design standard, and describes options and issues to move forward with implementation. - Highlights: • Building energy use is larger in rural China than in cities. • Rural buildings are very energy intensive, and energy use is growing with incomes. • A new design standard aims to help rural communities build more efficiently. • Important challenges remain with implementation

  18. 41 CFR 128-1.8005 - Seismic safety standards.

    Science.gov (United States)

    2010-07-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  19. Monitoring compliance with the International Code of Marketing of Breastmilk Substitutes in west Africa: multisite cross sectional survey in Togo and Burkina Faso

    Science.gov (United States)

    Aguayo, Victor M; Ross, Jay S; Kanon, Souleyman; Ouedraogo, Andre N

    2003-01-01

    Objectives To monitor compliance with the International Code of Marketing of Breastmilk Substitutes in health systems, sales outlets, distribution points, and the news media in Togo and Burkina Faso, west Africa. Design Multisite cross sectional survey. Participants Staff at 43 health facilities and 66 sales outlets and distribution points, 186 health providers, and 105 mothers of infants aged ⩽5 months in 16 cities. Results Six (14%) health facilities had received donations of breast milk substitutes. All donations were being given to mothers free of charge. Health providers in five (12%) health facilities had received free samples of breast milk substitutes for purposes other than professional research or evaluation. Health professionals in five (12%) health facilities had received promotional gifts from manufacturers. Promotional materials of commercial breast milk substitutes were found in seven (16%) health facilities. Special displays to market commercial breast milk substitutes were found in 29 (44%) sales and distribution points. Forty commercial breast milk substitutes violated the labelling standards of the code: 21 were manufactured by Danone, 11 by Nestlé, and eight by other national and international manufacturers. Most (148, 90%) health providers had never heard of the code, and 66 mothers (63%) had never received any counselling on breast feeding by their health providers. Conclusion In west Africa manufacturers are violating the code of marketing of breast milk substitutes. Comparable levels of code violations are observed with (Burkina Faso) or without (Togo) regulating legislation. Legislation must be accompanied by effective information, training, and monitoring systems to ensure that healthcare providers and manufacturers comply with evidence based practice and the code. What is already known on this topicAll member states of the World Health Assembly have reaffirmed their support for the International Code of Marketing of Breastmilk

  20. A development of computer code for evaluating internal radiation dose through ingestion and inhalation pathways

    International Nuclear Information System (INIS)

    Lee, Jeong Ho; Lee, Chang Woo; Choi, Yong Ho; Chun, Ki Jung; Kim, Kook Chan; Kim, Sang Bok; Kim, Jin Kyu

    1991-07-01

    The computer codes were developed to evaluate internal radiation dose when radioactive isotopes released from nuclear facilities are taken through ingestion and inhalation pathways. Food chain models and relevant data base representing the agricultural and social environment of Korea are set up. An equilibrium model-KFOOD, which can deal with routine releases from a nuclear facility and a dynamic model-ECOREA, which is suitable for the description of acute radioactivity release following nuclear accident. (Author)

  1. Overview of the ArbiTER edge plasma eigenvalue code

    Science.gov (United States)

    Baver, Derek; Myra, James; Umansky, Maxim

    2011-10-01

    The Arbitrary Topology Equation Reader, or ArbiTER, is a flexible eigenvalue solver that is currently under development for plasma physics applications. The ArbiTER code builds on the equation parser framework of the existing 2DX code, extending it to include a topology parser. This will give the code the capability to model problems with complicated geometries (such as multiple X-points and scrape-off layers) or model equations with arbitrary numbers of dimensions (e.g. for kinetic analysis). In the equation parser framework, model equations are not included in the program's source code. Instead, an input file contains instructions for building a matrix from profile functions and elementary differential operators. The program then executes these instructions in a sequential manner. These instructions may also be translated into analytic form, thus giving the code transparency as well as flexibility. We will present an overview of how the ArbiTER code is to work, as well as preliminary results from early versions of this code. Work supported by the U.S. DOE.

  2. When sparse coding meets ranking: a joint framework for learning sparse codes and ranking scores

    KAUST Repository

    Wang, Jim Jing-Yan

    2017-06-28

    Sparse coding, which represents a data point as a sparse reconstruction code with regard to a dictionary, has been a popular data representation method. Meanwhile, in database retrieval problems, learning the ranking scores from data points plays an important role. Up to now, these two problems have always been considered separately, assuming that data coding and ranking are two independent and irrelevant problems. However, is there any internal relationship between sparse coding and ranking score learning? If yes, how to explore and make use of this internal relationship? In this paper, we try to answer these questions by developing the first joint sparse coding and ranking score learning algorithm. To explore the local distribution in the sparse code space, and also to bridge coding and ranking problems, we assume that in the neighborhood of each data point, the ranking scores can be approximated from the corresponding sparse codes by a local linear function. By considering the local approximation error of ranking scores, the reconstruction error and sparsity of sparse coding, and the query information provided by the user, we construct a unified objective function for learning of sparse codes, the dictionary and ranking scores. We further develop an iterative algorithm to solve this optimization problem.

  3. Extension of the code COCOSYS to a dispersion code for smoke and carbon monoxide

    International Nuclear Information System (INIS)

    Sdouz, Gert; Mayrhofer, Robert

    2009-01-01

    The code COCOSYS (Containment Code SYStem) was developed by GRS in Germany to simulate processes and nuclear plant states during severe accidents in the containments of light water reactors. It contains several physical models, especially a module for aerosol behaviour. The goal of this work was to extend COCOSYS for applications in more general geometries mainly for complex public buildings. For the application in public buildings models for air condition systems and different boundary conditions according to different environments were developed. The principal application of the extended code COCOSYS is in the area of emergency situations especially in the simulation for carbon monoxide and smoke dispersion. After developing and implementing the new models several test calculations were performed to evaluate the functionality of the extended code. The comparison of the results with those of the original COCOSYS code showed no discrepancies. For the first realistic application several fire emergency scenarios in the Vienna General Hospital (AKH) were selected in agreement with the fire department of the hospital. One of the scenarios addresses the danger of carbon monoxide (CO) and smoke leaking into a fire protection section through a damaged fire protection flap. As a result of the dispersion simulation the CO-concentration in all of the rooms is obtained. Together with additional results as deposition and smoke dispersion the outcome of the simulation can be used for training. Among the next steps are the validation of the new models and the selection of critical scenarios. (author)

  4. Contributing to Net Zero Building: High Energy Efficient EIFS Wall Systems

    Energy Technology Data Exchange (ETDEWEB)

    Carbary, Lawrence D. [Dow Corning Corporation; Perkins, Laura L. [Dow Corning Corporation; Serino, Roland [Dryvit Systems, Inc; Preston, Bill [Dryvit Systems, Inc; Kosny, Jan [Fraunhofer USA, Inc. CSE

    2014-01-29

    The team led by Dow Corning collaborated to increase the thermal performance of exterior insulation and finishing systems (EIFS) to reach R-40 performance meeting the needs for high efficiency insulated walls. Additionally, the project helped remove barriers to using EIFS on retrofit commercial buildings desiring high insulated walls. The three wall systems developed within the scope of this project provide the thermal performance of R-24 to R-40 by incorporating vacuum insulation panels (VIPs) into an expanded polystyrene (EPS) encapsulated vacuum insulated sandwich element (VISE). The VISE was incorporated into an EIFS as pre-engineered insulation boards. The VISE is installed using typical EIFS details and network of trained installers. These three wall systems were tested and engineered to be fully code compliant as an EIFS and meet all of the International Building Code structural, durability and fire test requirements for a code compliant exterior wall cladding system. This system is being commercialized under the trade name Dryvit® Outsulation® HE system. Full details, specifications, and application guidelines have been developed for the system. The system has been modeled both thermally and hygrothermally to predict condensation potential. Based on weather models for Baltimore, MD; Boston, MA; Miami, FL; Minneapolis, MN; Phoenix, AZ; and Seattle, WA; condensation and water build up in the wall system is not a concern. Finally, the team conducted a field trial of the system on a building at the former Brunswick Naval Air Station which is being redeveloped by the Midcoast Regional Redevelopment Authority (Brunswick, Maine). The field trial provided a retrofit R-30 wall onto a wood frame construction, slab on grade, 1800 ft2 building, that was monitored over the course of a year. Simultaneous with the façade retrofit, the building’s windows were upgraded at no charge to this program. The retrofit building used 49% less natural gas during the winter of

  5. Study on the hydrogen explosion risk at reactor building during a severe accident

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    JNES carried out analysis on the hydrogen mixing and explosion at reactor building with CFD code and explosion analysis code to evaluate what exactly has happened at the reactor buildings of the Fukushima Daiichi NPS. Based on the MELCOR severe accident analysis results of Fukushima Daiichi Unit 1 and Unit 3, sensitivity study using the CFD code FLUENT was carried out on the parameter of the release rate, total mass of hydrogen gas, the release path between reactor building and PCV, and so on. Then an analysis using AUTODYN code was carried out to investigate the explosion at the reactor building of Unit 4 as well as Unit 1 and, Unit 3. With those analysis results it became possible to estimate the leaked path and the total amount of leaked hydrogen gas from PCV to reactor building. (author)

  6. Evaluation and considerations about fundamental periods of damaged reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    R. Ditommaso

    2013-07-01

    Full Text Available The aim of this paper is an empirical estimation of the fundamental period of reinforced concrete buildings and its variation due to structural and non-structural damage. The 2009 L'Aquila earthquake has highlighted the mismatch between experimental data and code provisions value not only for undamaged buildings but also for the damaged ones. The 6 April 2009 L'Aquila earthquake provided the first opportunity in Italy to estimate the fundamental period of reinforced concrete (RC buildings after a strong seismic sequence. A total of 68 buildings with different characteristics, such as age, height and damage level, have been investigated by performing ambient vibration measurements that provided their fundamental translational period. Four different damage levels were considered according with the definitions by EMS 98 (European Macroseismic Scale, trying to regroup the estimated fundamental periods versus building heights according to damage. The fundamental period of RC buildings estimated for low damage level is equal to the previous relationship obtained in Italy and Europe for undamaged buildings, well below code provisions. When damage levels are higher, the fundamental periods increase, but again with values much lower than those provided by codes. Finally, the authors suggest a possible update of the code formula for the simplified estimation of the fundamental period of vibration for existing RC buildings, taking into account also the inelastic behaviour.

  7. Error-Detecting Identification Codes for Algebra Students.

    Science.gov (United States)

    Sutherland, David C.

    1990-01-01

    Discusses common error-detecting identification codes using linear algebra terminology to provide an interesting application of algebra. Presents examples from the International Standard Book Number, the Universal Product Code, bank identification numbers, and the ZIP code bar code. (YP)

  8. International Capacity-Building Initiatives for National Bioethics Committees.

    Science.gov (United States)

    Gefenas, Eugenijus; Lukaseviciene, Vilma

    2017-05-01

    During the last two decades, national bioethics committees have been established in many countries all over the world. They vary with respect to their structure, composition, and working methods, but the main functions are similar. They are supposed to facilitate public debate on controversial bioethical issues and produce opinions and recommendations that can help inform the public and policy-makers. The dialogue among national bioethics committees is also increasingly important in the globalized world, where biomedical technologies raise ethical dilemmas that traverse national borders. It is not surprising, therefore, that the committees are established and active in the technologically advanced countries. There have also been a few international capacity-building initiatives in bioethics that have had a dual task: networking among existing national bioethics committees and helping establish such committees in those countries that still lack them. The problem is that, due to a lack of information, it is not clear what problems and challenges committees face in the transitioning societies often characterized as low- and middle-income countries. © 2017 The Hastings Center.

  9. ATLAS software configuration and build tool optimisation

    Science.gov (United States)

    Rybkin, Grigory; Atlas Collaboration

    2014-06-01

    ATLAS software code base is over 6 million lines organised in about 2000 packages. It makes use of some 100 external software packages, is developed by more than 400 developers and used by more than 2500 physicists from over 200 universities and laboratories in 6 continents. To meet the challenge of configuration and building of this software, the Configuration Management Tool (CMT) is used. CMT expects each package to describe its build targets, build and environment setup parameters, dependencies on other packages in a text file called requirements, and each project (group of packages) to describe its policies and dependencies on other projects in a text project file. Based on the effective set of configuration parameters read from the requirements files of dependent packages and project files, CMT commands build the packages, generate the environment for their use, or query the packages. The main focus was on build time performance that was optimised within several approaches: reduction of the number of reads of requirements files that are now read once per package by a CMT build command that generates cached requirements files for subsequent CMT build commands; introduction of more fine-grained build parallelism at package task level, i.e., dependent applications and libraries are compiled in parallel; code optimisation of CMT commands used for build; introduction of package level build parallelism, i. e., parallelise the build of independent packages. By default, CMT launches NUMBER-OF-PROCESSORS build commands in parallel. The other focus was on CMT commands optimisation in general that made them approximately 2 times faster. CMT can generate a cached requirements file for the environment setup command, which is especially useful for deployment on distributed file systems like AFS or CERN VMFS. The use of parallelism, caching and code optimisation significantly-by several times-reduced software build time, environment setup time, increased the efficiency of

  10. Thermal comfort in residential buildings by the millions

    DEFF Research Database (Denmark)

    Østergård, Torben; Maagaard, Steffen; Jensen, Rasmus Lund

    2016-01-01

    In Danish building code and many design briefings, criteria regarding thermal comfort are defined for “critical” rooms in residential buildings. Identifying the critical room is both difficult and time-consuming for large, multistory buildings. To reduce costs and time, such requirement often...

  11. Control and improvement of the internal museums environment; Controllo e risanamento dell`ambiente interno dei musei

    Energy Technology Data Exchange (ETDEWEB)

    Citterio, M.; Fanou, S.; Fasano, G.; Malosti, D. [ENEA, (Italy). Dipt. Energia

    1998-03-01

    The purpose of this work is to develop and to apply a general methodology in order to improve and to control the internal environmental parameters of historical buildings turned in cultural services centres. Proposal methodology is made of application of field monitoring, simulation models by mean of dynamic simulation codes and control and managing automatic systems. Innovation concerns not only the transfer of technologies and methodologies from scientific and industrial instrumentation field to cultural heritage conservation environment, but the introduction of a comprehensive approach (Intelligent Building) of the integrated managing of system of building/plants/communication/climate. The methodology was carried out in many of most important Italian Museums. In these buildings the internal micro climate was described, an architectural, plant, and/or managing system restoration was developed. In some cases a monitoring campaign, ducted after the application of studied modification, allowed to evaluate their benefit. This methodology can be very effective and can be largely diffuse in Italy, where museums are usually placed in important historical buildings, which have to be preserved, as well as the works of art inside.

  12. Strategies for Promoting Green Building Technologies Adoption in the Construction Industry—An International Study

    Directory of Open Access Journals (Sweden)

    Albert Ping Chuen Chan

    2017-06-01

    Full Text Available Because green building technologies (GBTs adoption is a promising way of ameliorating the sustainability performance of buildings, GBTs are receiving increased interest in the global construction community. The barriers to the adoption of GBTs, such as higher cost and lack of awareness, further indicate that proper strategies need to be devised for promoting the wider adoption of GBTs in buildings development. However, there exist limited empirical studies identifying the strategies for promoting GBTs adoption in the construction industry. This study aims to identify the strategies that are important for promoting GBTs adoption in construction. After a comprehensive literature review to identify strategies for the promotion of GBTs adoption, empirical data were gleaned through a questionnaire survey with 104 green building experts around the world. The analysis results validated the importance of all of the 12 promotion strategies used for the study. Green building experts from different countries and with different backgrounds had significant agreement on the relative importance ranking of the promotion strategies. Furthermore, “financial and further market-based incentives for GBTs adopters”, “availability of better information on cost and benefits of GBTs”, “mandatory governmental policies and regulations”, and “green rating and labeling” were identified as the top four important promotion strategies. The research findings provide a valuable reference to assist practitioners and policy makers in developing practical strategies for promoting GBTs adoption to eventually achieve the sustainable development of buildings. From the perspective of international experts, this study adds to the green building literature by offering empirical evidence of the important strategies for promoting GBTs adoption in the construction industry. Future research will investigate the interrelationships among the promotion strategies and their

  13. Energy efficiency outlook in China’s urban buildings sector through 2030

    International Nuclear Information System (INIS)

    McNeil, Michael A.; Feng, Wei; Rue du Can, Stephane de la; Khanna, Nina Zheng; Ke, Jing; Zhou, Nan

    2016-01-01

    This study uses bottom-up modeling framework in order to quantify potential energy savings and emission reduction impacts from the implementation of energy efficiency programs in the building sector in China. Policies considered include (1) accelerated building codes in residential and commercial buildings, (2) increased penetration of district heat metering and controls, (3) district heating efficiency improvement, (4) building energy efficiency labeling programs and (5) retrofits of existing commercial buildings. Among these programs, we found that the implementation of building codes provide by far the largest savings opportunity, leading to an overall 17% reduction in overall space heating and cooling demand relative to the baseline. Second are energy efficiency labels with 6%, followed by reductions of losses associated with district heating representing 4% reduction and finally, retrofits representing only about a 1% savings. - Highlights: • We use a bottom-up modeling approach to quantify emission reduction from efficiency programs. • Heating and cooling are the main focus of this study. • We find that building codes lead to 17% reduction compare to the baseline. • Other programs analyzed concern district heat, building labeling and retrofits of buildings.

  14. Who's keeping the code? Compliance with the international code for the marketing of breast-milk substitutes in Greater Glasgow.

    Science.gov (United States)

    McInnes, Rhona J; Wright, Charlotte; Haq, Shogufta; McGranachan, Margaret

    2007-07-01

    To evaluate compliance with the World Health Organization's International Code of Marketing of Breast-milk Substitutes in primary care, after the introduction of strict local infant feeding guidelines. An audit form was sent to all community-based health professionals with an infant feeding remit. Walking tours were conducted in a random sample of community care facilities. Greater Glasgow Primary Care Division. (1) Primary-care staff with an infant feeding remit; (2) community health-care facilities. Contact with manufacturers of breast-milk substitutes (BMS) and BMS company personnel, free samples or incentives, and advertising of BMS. Contact with company personnel was minimal, usually unsolicited and was mainly to provide product information. Free samples of BMS or feeding equipment were rare but childcare or parenting literature was more prevalent. Staff voiced concerns about the lack of relevant information for bottle-feeding mothers and the need to support the mother's feeding choice. One-third of facilities were still displaying materials non-compliant with the Code, with the most common materials being weight conversion charts and posters. Contact between personnel from primary care and BMS companies was minimal and generally unsolicited. The presence of materials from BMS companies in health-care premises was more common. Due to the high level of bottle-feeding in Glasgow, primary-care staff stated a need for information about BMS.

  15. Nuclear-thermal-coupled optimization code for the fusion breeding blanket conceptual design

    International Nuclear Information System (INIS)

    Li, Jia; Jiang, Kecheng; Zhang, Xiaokang; Nie, Xingchen; Zhu, Qinjun; Liu, Songlin

    2016-01-01

    Highlights: • A nuclear-thermal-coupled predesign code has been developed for optimizing the radial build arrangement of fusion breeding blanket. • Coupling module aims at speeding up the efficiency of design progress by coupling the neutronics calculation code with the thermal-hydraulic analysis code. • Radial build optimization algorithm aims at optimal arrangement of breeding blanket considering one or multiple specified objectives subject to the design criteria such as material temperature limit and available TBR. - Abstract: Fusion breeding blanket as one of the key in-vessel components performs the functions of breeding the tritium, removing the nuclear heat and heat flux from plasma chamber as well as acting as part of shielding system. The radial build design which determines the arrangement of function zones and material properties on the radial direction is the basis of the detailed design of fusion breeding blanket. For facilitating the radial build design, this study aims for developing a pre-design code to optimize the radial build of blanket with considering the performance of nuclear and thermal-hydraulic simultaneously. Two main features of this code are: (1) Coupling of the neutronics analysis with the thermal-hydraulic analysis to speed up the analysis progress; (2) preliminary optimization algorithm using one or multiple specified objectives subject to the design criteria in the form of constrains imposed on design variables and performance parameters within the possible engineering ranges. This pre-design code has been applied to the conceptual design of water-cooled ceramic breeding blanket in project of China fusion engineering testing reactor (CFETR).

  16. Nuclear-thermal-coupled optimization code for the fusion breeding blanket conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jia, E-mail: lijia@ustc.edu.cn [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230027, Anhui (China); Jiang, Kecheng; Zhang, Xiaokang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, Anhui (China); Nie, Xingchen [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230027, Anhui (China); Zhu, Qinjun; Liu, Songlin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, Anhui (China)

    2016-12-15

    Highlights: • A nuclear-thermal-coupled predesign code has been developed for optimizing the radial build arrangement of fusion breeding blanket. • Coupling module aims at speeding up the efficiency of design progress by coupling the neutronics calculation code with the thermal-hydraulic analysis code. • Radial build optimization algorithm aims at optimal arrangement of breeding blanket considering one or multiple specified objectives subject to the design criteria such as material temperature limit and available TBR. - Abstract: Fusion breeding blanket as one of the key in-vessel components performs the functions of breeding the tritium, removing the nuclear heat and heat flux from plasma chamber as well as acting as part of shielding system. The radial build design which determines the arrangement of function zones and material properties on the radial direction is the basis of the detailed design of fusion breeding blanket. For facilitating the radial build design, this study aims for developing a pre-design code to optimize the radial build of blanket with considering the performance of nuclear and thermal-hydraulic simultaneously. Two main features of this code are: (1) Coupling of the neutronics analysis with the thermal-hydraulic analysis to speed up the analysis progress; (2) preliminary optimization algorithm using one or multiple specified objectives subject to the design criteria in the form of constrains imposed on design variables and performance parameters within the possible engineering ranges. This pre-design code has been applied to the conceptual design of water-cooled ceramic breeding blanket in project of China fusion engineering testing reactor (CFETR).

  17. Reversible machine code and its abstract processor architecture

    DEFF Research Database (Denmark)

    Axelsen, Holger Bock; Glück, Robert; Yokoyama, Tetsuo

    2007-01-01

    A reversible abstract machine architecture and its reversible machine code are presented and formalized. For machine code to be reversible, both the underlying control logic and each instruction must be reversible. A general class of machine instruction sets was proven to be reversible, building...

  18. Analysis of quantum error-correcting codes: Symplectic lattice codes and toric codes

    Science.gov (United States)

    Harrington, James William

    Quantum information theory is concerned with identifying how quantum mechanical resources (such as entangled quantum states) can be utilized for a number of information processing tasks, including data storage, computation, communication, and cryptography. Efficient quantum algorithms and protocols have been developed for performing some tasks (e.g. , factoring large numbers, securely communicating over a public channel, and simulating quantum mechanical systems) that appear to be very difficult with just classical resources. In addition to identifying the separation between classical and quantum computational power, much of the theoretical focus in this field over the last decade has been concerned with finding novel ways of encoding quantum information that are robust against errors, which is an important step toward building practical quantum information processing devices. In this thesis I present some results on the quantum error-correcting properties of oscillator codes (also described as symplectic lattice codes) and toric codes. Any harmonic oscillator system (such as a mode of light) can be encoded with quantum information via symplectic lattice codes that are robust against shifts in the system's continuous quantum variables. I show the existence of lattice codes whose achievable rates match the one-shot coherent information over the Gaussian quantum channel. Also, I construct a family of symplectic self-dual lattices and search for optimal encodings of quantum information distributed between several oscillators. Toric codes provide encodings of quantum information into two-dimensional spin lattices that are robust against local clusters of errors and which require only local quantum operations for error correction. Numerical simulations of this system under various error models provide a calculation of the accuracy threshold for quantum memory using toric codes, which can be related to phase transitions in certain condensed matter models. I also present

  19. Advanced thermohydraulic simulation code for transients in LMFBRs (SSC-L code)

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, A.K.

    1978-02-01

    Physical models for various processes that are encountered in preaccident and transient simulation of thermohydraulic transients in the entire liquid metal fast breeder reactor (LMFBR) plant are described in this report. A computer code, SSC-L, was written as a part of the Super System Code (SSC) development project for the ''loop''-type designs of LMFBRs. This code has the self-starting capability, i.e., preaccident or steady-state calculations are performed internally. These results then serve as the starting point for the transient simulation.

  20. Advanced thermohydraulic simulation code for transients in LMFBRs (SSC-L code)

    International Nuclear Information System (INIS)

    Agrawal, A.K.

    1978-02-01

    Physical models for various processes that are encountered in preaccident and transient simulation of thermohydraulic transients in the entire liquid metal fast breeder reactor (LMFBR) plant are described in this report. A computer code, SSC-L, was written as a part of the Super System Code (SSC) development project for the ''loop''-type designs of LMFBRs. This code has the self-starting capability, i.e., preaccident or steady-state calculations are performed internally. These results then serve as the starting point for the transient simulation

  1. JASMINE-pro: A computer code for the analysis of propagation process in steam explosions. User's manual

    International Nuclear Information System (INIS)

    Yang, Yanhua; Nilsuwankosit, Sunchai; Moriyama, Kiyofumi; Maruyama, Yu; Nakamura, Hideo; Hashimoto, Kazuichiro

    2000-12-01

    A steam explosion is a phenomenon where a high temperature liquid gives its internal energy very rapidly to another low temperature volatile liquid, causing very strong pressure build up due to rapid vaporization of the latter. In the field of light water reactor safety research, steam explosions caused by the contact of molten core and coolant has been recognized as a potential threat which could cause failure of the pressure vessel or the containment vessel during a severe accident. A numerical simulation code JASMINE was developed at Japan Atomic Energy Research Institute (JAERI) to evaluate the impact of steam explosions on the integrity of reactor boundaries. JASMINE code consists of two parts, JASMINE-pre and -pro, which handle the premixing and propagation phases in steam explosions, respectively. JASMINE-pro code simulates the thermo-hydrodynamics in the propagation phase of a steam explosion on the basis of the multi-fluid model for multiphase flow. This report, 'User's Manual', gives the usage of JASMINE-pro code as well as the information on the code structures which should be useful for users to understand how the code works. (author)

  2. Non-binary Hybrid LDPC Codes: Structure, Decoding and Optimization

    OpenAIRE

    Sassatelli, Lucile; Declercq, David

    2007-01-01

    In this paper, we propose to study and optimize a very general class of LDPC codes whose variable nodes belong to finite sets with different orders. We named this class of codes Hybrid LDPC codes. Although efficient optimization techniques exist for binary LDPC codes and more recently for non-binary LDPC codes, they both exhibit drawbacks due to different reasons. Our goal is to capitalize on the advantages of both families by building codes with binary (or small finite set order) and non-bin...

  3. Code of Practice on the International Transboundary Movement of Radioactive Waste; Codigo De Practica Sobre Movimientos Internacionales Transfronterizos De Desechos Radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-11-14

    On 21 September 1990, the General Conference, by resolution GC(XXXIV)/RES/530, adopted a Code of Practice on the International Transboundary Movement of Radioactive Waste and requested the Director General - inter alia - to take all necessary steps to ensure wide dissemination of the Code of Practice at both the national and the international level. The Code of Practice was elaborated by a Group of Experts established pursuant to resolution GC(XXXII)/RES/490 adopted by the General Conference in 1988. The text of the Code of Practice is reproduced herewith for the information of all Member States [Spanish] El 21 de septiembre de 1990, la Conferencia General, en su resolueion GC(XXXIV)/RES/53O, aprobo un Codigo de Practica sobre movimientos internacionales transfronterizos de desechos radiactivos y pidio al Director General, entre otras cosas, que tomase todas las medidas necesarias para lograr una amplia difusion del Codigo de Practica en los planos nacional e internacional. El Codigo de Practica lo elaboro un Grupo de Expertos establecido en cumplimiento de la resolucion GC(XXXII)/RES/49O aprobada por la Conferencia General en 1988. En el presente documento se reproduce el texto del Codigo de Practica para informacion de todos los Estados Miembros.

  4. Considering soil-structure interaction effects in the equivalent static analysis method of the Iranian of the Iranian seismic building code

    International Nuclear Information System (INIS)

    Shakib, H.; Dehghani Ashkezari, G.

    2002-01-01

    In this study, based on the equivalent static analysis method of the Iranian seismic code, an algorithm is presented to consider the soil-structure interaction (SSI) effects. Modifications of free field motion and structural properties like period and damping due to soil situation are considered in the proposed algorithm. An increase for fundamental period of structure and a modification (usually increase) for it's effective damping are observed. The increase of period is due to the flexibility of the soil foundation and modification of damping is due to the dissipating energy in soil. In order to propose the relative expressions in the presented algorithm, the soil-structure analyses of 8, 10, 13 and 16 stories frames are carried out. By considering the NEHRP soil-structure interaction algorithm and findings of soil-structure interaction analyses carried out in this study, the algorithm based on the equivalent static analysis method of the Iranian seismic building code to consider the effect of soil-structure interaction

  5. Can High-Performance Equipment Lead to a Low-Performance Building?

    Energy Technology Data Exchange (ETDEWEB)

    Jonlin, Duane; Thornton, Brian A.; Rosenberg, Michael I.

    2016-08-22

    The performance-based compliance alternative available in most energy codes, intended to provide energy efficiency equivalent to that of prescriptive compliance while allowing innovation and design flexibility, can instead result in sub-standard energy performance in both the short and the long term. The potential deficiencies in modeled buildings originate with subtleties in the energy modeling rules, allowing building systems that consume more energy than their real-world, prescriptively-designed counterparts. This performance gap is exacerbated over subsequent decades as less efficient permanent features of the building remain while elements with shorter lives are regularly upgraded in most buildings. This paper summarizes an investigation into the topic for Pacific Northwest National Laboratory and the City of Seattle, including identification of the principal deficiencies exploited in the modeling path, and several potential code amendments that could resolve these deficiencies and establish better equivalency between prescriptive and performance compliance paths. The study, focusing on Seattle and Washington State energy codes, offers lessons and implications for other jurisdictions and energy codes.

  6. 76 FR 77237 - U.S. National Authority for the WHO Global Code of Practice on the International Recruitment of...

    Science.gov (United States)

    2011-12-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Health Resources and Services Administration U.S. National Authority for the WHO Global Code of Practice on the International Recruitment of Health Personnel; Notice of Public Meeting AGENCY: Health Resources and Services Administration, HHS; Office of Global Affairs...

  7. Energy-efficient buildings program evaluations. Volume 1: Findings and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.D.; Mayi, D.; Edgemon, S.D.

    1997-04-01

    This study was conducted for the US Department of Energy (DOE) by Pacific Northwest National Laboratory (PNNL). DOE operates the Building Standards and Guidelines Program (BSGP) to increase the effectiveness of building energy codes, standards, and guidelines. The main purpose of this report is to lay the groundwork for conducting an overall evaluation of the program and its effectiveness. Another purpose of this report is to summarize an extensive set of relevant evaluations and provide a building efficiency and program evaluation information resource for program designers, managers, and evaluators. This study presents information from 119 evaluations that have been conducted of both utility and code programs related to energy efficiency in new residential and commercial buildings. The authors used the information in these evaluations to identify major themes and lessons learned from utility and code programs. They also used the information to gain insights into appropriate evaluation methodologies and establish guidelines for designing future evaluations and an evaluation of the BSGP. The report presents general lessons about evaluating programs that have implications for future evaluations included the following. The evaluations provided the basis for developing an effective evaluation approach for residential building energy-efficiency codes and other energy-efficiency programs and other insights for conducting commercial building program evaluations. The findings for conducting effective evaluations are categorized by steps in the evaluation process.

  8. Exposure mode study to xenon-133 in a reactor building

    International Nuclear Information System (INIS)

    Perier, Aurelien

    2014-01-01

    The work described in this thesis focuses on the external and internal dose assessment to xenon-133. During the nuclear reactor operation, fission products and radioactive inert gases, as 133 Xe, are generated and might be responsible for the exposure of workers in case of clad defect. Particle Monte Carlo transport code is adapted in radioprotection to quantify dosimetric quantities. The study of exposure to xenon-133 is conducted by using Monte-Carlo simulations based on GEANT4, an anthropomorphic phantom, a realistic geometry of the reactor building, and compartmental models. The external exposure inside a reactor building is conducted with a realistic and conservative exposure scenario. The effective dose rate and the eye lens equivalent dose rate are determined by Monte-Carlo simulations. Due to the particular emission spectrum of xenon-133, the equivalent dose rate to the lens of eyes is discussed in the light of expected new eye dose limits. The internal exposure occurs while xenon-133 is inhaled. The lungs are firstly exposed by inhalation, and their equivalent dose rate is obtained by Monte-Carlo simulations. A biokinetic model is used to evaluate the internal exposure to xenon-133. This thesis gives us a better understanding to the dosimetric quantities related to external and internal exposure to xenon-133. Moreover the impacts of the dosimetric changes are studied on the current and future dosimetric limits. The dosimetric quantities are lower than the current and future dosimetric limits. (author)

  9. Building regulations in energy efficiency: Compliance in England and Wales

    International Nuclear Information System (INIS)

    Pan Wei; Garmston, Helen

    2012-01-01

    There is an international pragmatic shift towards the use of building energy regulations, standards and codes to reduce building energy consumption. The UK Government revised Building Regulations in 2002, 2006 and 2010, towards more stringent energy efficiency standards and ultimately the target of ‘zero carbon’ new homes from 2016. This paper aims to: reveal levels of compliance with energy Building Regulations of new-build dwellings in England and Wales; explore underlying issues; and identify possible solutions. In total 376 new-build dwellings were investigated. The compliance revealed was poor, at a level of 35%; accompanied by 43% ‘grey compliance’ and 21% ‘grey non-compliance’ (due to insufficient evidence of achieving required carbon emissions reductions). It is a serious concern when building control approves so many dwellings when insufficient evidence of compliance has been received. Underlying issues were centred on: incorrect compilation and/or insufficient submission of carbon emissions calculations by builders/developers; inappropriate timings of such submissions; and a paucity of proper checks by building control. Exploring these issues reveals a complex system of factors influencing energy regulations compliance, which involves a wide range of stakeholders. The findings should inform the formulation and implementation of energy efficiency building regulations and policy in the future. - Highlights: ► The compliance with energy Building Regulations (England and Wales) was poor. ► The problematic implementation of energy Building Regulations is a serious concern. ► Identified issues suggest a lack of knowledge of builders and building control. ► There is a complex system of factors influencing energy regulations compliance. ► A systems approach is needed to improve compliance, while training is crucial.

  10. The theoretical modelling of aerosol behaviour within containment buildings

    International Nuclear Information System (INIS)

    Dunbar, I.H.

    1988-01-01

    The modelling of the deposition of aerosol particles within the containment building plays an important part in determining the effectiveness of the building in reducing releases of activity following accidents. This paper describes attempts to ensure the accuracy of computer codes which model aerosol behaviour, with special reference to the code AEROSIM-M. Code intercomparisons have been used to test the reliability of the coding and the accuracy of the numerical methods. Those codes which assume that the particle size distribution is always lognormal give significantly different results from those which do not make this assumption but instead discretise the range of particle sizes. When the same physical assumptions are made, the predictions of different discrete codes are in reasonable agreement. In comparisons between an earlier version of AEROSIM and sodium fire experiments, the code achieved good agreement on the overall time-scale of deposition. An extensive set of tests of AEROSIM-M against experiments relevant to LWR conditions is underway. (author)

  11. 78 FR 23550 - Department of Energy's (DOE) Participation in Development of the International Energy...

    Science.gov (United States)

    2013-04-19

    ... building energy codes by periodically reviewing the technical and economic basis of the voluntary building... and modification of such codes. (42 U.S.C. 6836(b)) B. Background The IECC serves as a model building... building energy codes is through participation in the IECC development process. DOE participates in the ICC...

  12. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    International Nuclear Information System (INIS)

    2002-01-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in 60 Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and satisfies

  13. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in {sup 60}Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and

  14. Environmental construction of nano-material design codes. The example of simulation codes used in the CMD workshop

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Mikiya [Japan Atomic Energy Research Inst., Center for Promotion of Computational Science and Engineering, Kizu, Kyoto (Japan)

    2003-05-01

    Generally it is well known that the R and D works on new materials or devices will play a central role on the evolution of future society. But, the old ways based on the empirical and experimental approach have already reached the limit, especially for dealing with a strange substance and material. The structure of a substance and material is needed to be dealt with in detail by quantum mechanics, because the limit on accuracy has come in sight in the calculation using a classical theory. The research on the latest electronic state calculation technique founded on quantum mechanics made a great advance as the technique of solving these problems as well as the technique of a computational materials design. It enables the prediction of material properties because it is based on First Principles. Therefore, in the future it is expected to have a very high possibility of becoming a breakthrough in such a situation. In this article, the example calculation results by PC cluster on the codes (MACHIKANEYAMA-2000, OSAKA-2000) used in the CMD (Computational Materials Design) workshop, held on Sep. 19-21, at ITBL-Building and International Institute for Advanced Studies under the auspices of the University of Osaka, are described. Furthermore, the graphical user interfaces on the codes are examined. (author)

  15. AECL international standard problem ISP-41 FU/1 follow-up exercise (Phase 1): Containment Iodine Computer Code Exercise: Parametric Studies

    International Nuclear Information System (INIS)

    Ball, J.; Glowa, G.; Wren, J.; Ewig, F.; Dickenson, S.; Billarand, Y.; Cantrel, L.; Rydl, A.; Royen, J.

    2001-06-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I- concentration. The codes used in this exercise were IODE (IPSN), IODE (NRIR), IMPAIR (GRS), INSPECT (AEAT), IMOD (AECL) and LIRIC (AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained from intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (authors)

  16. Comparative Education and Research Capacity Building: Reflections on International Transfer and the Significance of Context

    Directory of Open Access Journals (Sweden)

    Michael Crossley

    2012-04-01

    Full Text Available Recent years have seen a resurgence of interest in comparative and international education, along with a fundamental reconceptualisation of this distinctive multidisciplinary field of study. The nature and significance of these developments are explored with particular reference to their implications for broader research capacity building initiatives worldwide. In doing so, a critique of the international transfer of globally dominant research modalities and strategies is presented--along with arguments for increased attention to context sensitivity in both international development cooperation and educational research in general. Illustrative examples that support these arguments are drawn from the author's own research, from an analysis of emergent educational policy debates in the UK, and from related studies being carried out in Malaysia. In concluding, the strategic role of comparative research traditions and perspectives in a rapidly globalizing world is highlighted, while supporting the promotion of new initiative and research centres for comparative and international education.

  17. Relevance and Effectiveness of the WHO Global Code Practice on the International Recruitment of Health Personnel – Ethical and Systems Perspectives

    Directory of Open Access Journals (Sweden)

    Ruairi Brugha

    2015-06-01

    Full Text Available The relevance and effectiveness of the World Health Organization’s (WHO’s Global Code of Practice on the International Recruitment of Health Personnel is being reviewed in 2015. The Code, which is a set of ethical norms and principles adopted by the World Health Assembly (WHA in 2010, urges members states to train and retain the health personnel they need, thereby limiting demand for international migration, especially from the under-staffed health systems in low- and middle-income countries. Most countries failed to submit a first report in 2012 on implementation of the Code, including those source countries whose health systems are most under threat from the recruitment of their doctors and nurses, often to work in 4 major destination countries: the United States, United Kingdom, Canada and Australia. Political commitment by source country Ministers of Health needs to have been achieved at the May 2015 WHA to ensure better reporting by these countries on Code implementation for it to be effective. This paper uses ethics and health systems perspectives to analyse some of the drivers of international recruitment. The balance of competing ethics principles, which are contained in the Code’s articles, reflects a tension that was evident during the drafting of the Code between 2007 and 2010. In 2007-2008, the right of health personnel to migrate was seen as a preeminent principle by US representatives on the Global Council which co-drafted the Code. Consensus on how to balance competing ethical principles – giving due recognition on the one hand to the obligations of health workers to the countries that trained them and the need for distributive justice given the global inequities of health workforce distribution in relation to need, and the right to migrate on the other hand – was only possible after President Obama took office in January 2009. It is in the interests of all countries to implement the Global Code and not just those that

  18. Analyzing Design Heating Loads in Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-01

    Super-insulated homes offer many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for super insulated homes.

  19. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    2000-01-01

    The International Atomic Energy Agency published in 1987 an International Code of Practice entitled 'Absorbed Dose Determination in Photon and Electron Beams' (IAEA Technical Reports Series No. 277 (TRS-277)), recommending procedures to obtain the absorbed dose in water from measurements made with an ionization chamber in external beam radiotherapy. A second edition of TRS-277 was published in 1997 updating the dosimetry of photon beams, mainly kilovoltage X rays. Another International Code of Practice for radiotherapy dosimetry entitled 'The Use of Plane-Parallel Ionization Chambers in High Energy Electron and Photon Beams' (IAEA Technical Reports Series No. 381 (TRS-381)) was published in 1997 to further update TRS-277 and complement it with respect to the area of parallel-plate ionization chambers. Both codes have proven extremely valuable for users involved in the dosimetry of the radiation beams used in radiotherapy. In TRS-277 the calibration of the ionization chambers was based on primary standards of air kerma; this procedure was also used in TRS-381, but the new trend of calibrating ionization chambers directly in a water phantom in terms of absorbed dose to water was introduced. The development of primary standards of absorbed dose to water for high energy photon and electron beams, and improvements in radiation dosimetry concepts, offer the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. The dosimetry of kilovoltage X rays, as well as that of proton and heavy ion beams, interest in which has grown considerably in recent years, can also be based on these standards. Thus a coherent dosimetry system based on standards of absorbed dose to water is possible for practically all radiotherapy beams. Many Primary Standard Dosimetry Laboratories (PSDLs) already provide calibrations in terms of absorbed dose to water at the radiation quality of 60 Co gamma rays. Some laboratories have extended calibrations to high energy photon and

  20. How to Build MCNP 6.2

    Energy Technology Data Exchange (ETDEWEB)

    Bull, Jeffrey S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    This presentation describes how to build MCNP 6.2. MCNP®* 6.2 can be compiled on Macs, PCs, and most Linux systems. It can also be built for parallel execution using both OpenMP and Messing Passing Interface (MPI) methods. MCNP6 requires Fortran, C, and C++ compilers to build the code.

  1. Sub-grouping of Plasmodium falciparum 3D7 var genes based on sequence analysis of coding and non-coding regions

    DEFF Research Database (Denmark)

    Lavstsen, Thomas; Salanti, Ali; Jensen, Anja T R

    2003-01-01

    and organization of the 3D7 PfEMP1 repertoire was investigated on the basis of the complete genome sequence. METHODS: Using two tree-building methods we analysed the coding and non-coding sequences of 3D7 var and rif genes as well as var genes of other parasite strains. RESULTS: var genes can be sub...

  2. Seafloor 2030 - Building a Global Ocean Map through International Collaboration

    Science.gov (United States)

    Ferrini, V. L.; Wigley, R. A.; Falconer, R. K. H.; Jakobsson, M.; Allen, G.; Mayer, L. A.; Schmitt, T.; Rovere, M.; Weatherall, P.; Marks, K. M.

    2016-12-01

    With more than 85% of the ocean floor unmapped, a huge proportion of our planet remains unexplored. Creating a comprehensive map of seafloor bathymetry remains a true global challenge that can only be accomplished through collaboration and partnership between governments, industry, academia, research organizations and non-government organizations. The objective of Seafloor 2030 is to comprehensively map the global ocean floor to resolutions that enable exploration and improved understanding of ocean processes, while informing maritime policy and supporting the management of natural marine resources for a sustainable Blue Economy. Seafloor 2030 is the outcome of the Forum for Future of Ocean Floor Mapping held in Monaco in June 2016, which was held under the auspices of GEBCO and the Nippon Foundation of Japan. GEBCO is the only international organization mandated to map the global ocean floor and is guided by the International Hydrographic Organization (IHO) and the Intergovernmental Oceanographic Commission of UNESCO. The task of completely mapping the ocean floor will require new global coordination to ensure that both existing data are identified and that new mapping efforts are coordinated to help efficiently "map the gaps." Fundamental to achieving Seafloor 2030 will be greater access to data, tools and technology, particularly for developing and coastal nations. This includes bathymetric post-processing and analysis software, database technology, computing infrastructure and gridding techniques as well as the latest developments in seafloor mapping methods and emerging crowd-sourced bathymetry initiatives. The key to achieving this global bathymetric map is capacity building and education - including greater coordination between scientific research and industry and the effective engagement of international organizations such as the United Nations.

  3. Development of 3D models of buildings for containment of the nuclear power plant of Almaraz and of the Trillo Nuclear with the GOTHIC 8.0 code

    International Nuclear Information System (INIS)

    Jimenez, G.; Bocanegra Melian, R.; Fernandez Cosils, K.; Barreira Pereira, P.; Rey Peinado, L.; Posada Barral, J. M.

    2014-01-01

    The objective of the first phase of the research of CNAT and the UPM project is the construction of several three-dimensional models detailed GOTHIC 8.0 code of containment of a buildings plant type PWR-W and KWU, corresponding to the Central Nuclear de Almaraz (CNA) and Trillo (CNT) respectively. (Author)

  4. Performance curves of room air conditioners for building energy simulation tools

    International Nuclear Information System (INIS)

    Meissner, José W.; Abadie, Marc O.; Moura, Luís M.; Mendonça, Kátia C.; Mendes, Nathan

    2014-01-01

    Highlights: • Experimental characteristic curves for two room air conditioners are presented. • These results can be implemented in building simulation codes. • The energy consumption under different conditions can numerically determine. • The labeled higher energy efficiency product not always provides the best result. - Abstract: In order to improve the modeling of air conditioners in building simulation tools, the characteristic curves for total cooling capacity, sensible cooling capacity and energy efficiency ratio of two room units were determined. They were obtained by means of standard capacity tests on climatic chambers in a set of environmental conditions described by external dry- and internal wet bulb temperatures. Afterward, the performance of these two units and that of four other units, with and without taking into to account the thermodynamic variations of the surrounding environments on it, were compared using a whole building simulation program for simulating a conditioned space. The comparative analysis showed that the air conditioner with the higher energy efficiency rating not always provides the lowest power consumption in real conditions of use

  5. Comparative Policy Study for Green Buildings in U.S. and China

    Energy Technology Data Exchange (ETDEWEB)

    Khanna, Nina; Romankiewicz, John; Feng, Wei; Zhou, Nan; Ye, Qing

    2014-04-01

    Prominent barriers facing the U.S. green building industry include the fact that government bodies that supervise health, fire safety, land, and other public operations are slow to revise codes to accommodate green building (regulatory barrier). In China, the lack of a green building professional accreditation process similar to the Leadership in Energy and Environmental Design (LEED) AP process limits the green building workforce capacity development (informational barrier). The main policies highlighted in this report to tackle these barriers are 1) comprehensive codes and labeling plan (informational, institutional), 2) government-led targets and demonstrations (risk), 3) education and awareness programs (informational), 4) fiscal policy that supports green building investment (financial), and 5) integrated design promotion (institutional, financial).

  6. Application of the new International Code of Practice for dosimetry in diagnostic radiology to conventional exams

    International Nuclear Information System (INIS)

    Martinez Gonzalez, A.; Cardenas Herrera, J.; Walwyn Salas, G.; Machado, A.; Mora Machado, R. de la

    2008-01-01

    Full text: During the recent years, a policy for updating and installation of the X-ray equipment, specialized as well as conventional, have been carrying out, in Cuba. Conventional equipment has reached almost the whole primary level. Considering this situation, the quality control programs and clinical dosimetry have become even more important. Regarding the last one, an International Code of Practice for Dosimetry in Diagnostic Radiology had been published by the International Atomic Energy Agency in order to been used as a guide and to standardize the methodologies used to evaluate the patient exposure in radiodiagnostic. Taken into consideration the above reasons, an assessment of the aforementioned code of practice was done in order to choose the most feasible methodology to implement in the country. The evaluation was performed considering the lack of dosimetric equipment and medical physicists in this practice, in the interests of increasing the measurements scope to a large number of services as well as to standardize the methodology on a national scale. The present work shows the results obtained from the application of the new code of practice to conventional radiology exams in some medical institutions. Out of 3 on patients measurements methodologies described in the code of practice, the one of measurement of the incident air kerma was chosen. This methodology allow to the physicist to focus on the diagnostic equipment tests and to delegate the collection of the patient and exposure parameters data to the technicians, which make the increased of the patient and diagnostic departments sample, possible. The measurements were carried out in 2 hospital of the capital. The exams involved in the assessments were thorax PA, lumbar spine AP and lumbar spine LAT. In every diagnostic service, 25 patients were chosen on each projection. The weight and height average of the patient sample were 68 kg and 167 cm respectively. In the assessment were considered only

  7. Numerical Tokamak Project code comparison

    International Nuclear Information System (INIS)

    Waltz, R.E.; Cohen, B.I.; Beer, M.A.

    1994-01-01

    The Numerical Tokamak Project undertook a code comparison using a set of TFTR tokamak parameters. Local radial annulus codes of both gyrokinetic and gyrofluid types were compared for both slab and toroidal case limits assuming ion temperature gradient mode turbulence in a pure plasma with adiabatic electrons. The heat diffusivities were found to be in good internal agreement within ± 50% of the group average over five codes

  8. JASMINE-pro: A computer code for the analysis of propagation process in steam explosions. User's manual

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yanhua; Nilsuwankosit, Sunchai; Moriyama, Kiyofumi; Maruyama, Yu; Nakamura, Hideo; Hashimoto, Kazuichiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2000-12-01

    A steam explosion is a phenomenon where a high temperature liquid gives its internal energy very rapidly to another low temperature volatile liquid, causing very strong pressure build up due to rapid vaporization of the latter. In the field of light water reactor safety research, steam explosions caused by the contact of molten core and coolant has been recognized as a potential threat which could cause failure of the pressure vessel or the containment vessel during a severe accident. A numerical simulation code JASMINE was developed at Japan Atomic Energy Research Institute (JAERI) to evaluate the impact of steam explosions on the integrity of reactor boundaries. JASMINE code consists of two parts, JASMINE-pre and -pro, which handle the premixing and propagation phases in steam explosions, respectively. JASMINE-pro code simulates the thermo-hydrodynamics in the propagation phase of a steam explosion on the basis of the multi-fluid model for multiphase flow. This report, 'User's Manual', gives the usage of JASMINE-pro code as well as the information on the code structures which should be useful for users to understand how the code works. (author)

  9. Code of ethics for dental researchers.

    Science.gov (United States)

    2014-01-01

    The International Association for Dental Research, in 2009, adopted a code of ethics. The code applies to members of the association and is enforceable by sanction, with the stated requirement that members are expected to inform the association in cases where they believe misconduct has occurred. The IADR code goes beyond the Belmont and Helsinki statements by virtue of covering animal research. It also addresses issues of sponsorship of research and conflicts of interest, international collaborative research, duty of researchers to be informed about applicable norms, standards of publication (including plagiarism), and the obligation of "whistleblowing" for the sake of maintaining the integrity of the dental research enterprise as a whole. The code is organized, like the ADA code, into two sections. The IADR principles are stated, but not defined, and number 12, instead of the ADA's five. The second section consists of "best practices," which are specific statements of expected or interdicted activities. The short list of definitions is useful.

  10. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    Science.gov (United States)

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  11. 76 FR 27843 - National Building Safety Month, 2011

    Science.gov (United States)

    2011-05-13

    ... organizations and the public and private sectors--to implement effective standards and codes that sustain safe... and fire prevention codes help us withstand, mitigate, and rapidly recover from hurricanes, winter... Building Safety Month. I encourage citizens, government agencies, private businesses, nonprofit...

  12. Photovoltaics for Buildings Cutting-Edge PV

    International Nuclear Information System (INIS)

    Hayter, S. J.; Martin, R. L.

    1998-01-01

    Photovoltaic (PV) technology development for building-integrated applications (commonly called PV for Buildings) is one of the fastest growing areas in the PV industry. Buildings represent a huge potential market for photovoltaics because they consume approximately two-thirds of the electricity consumed in the US. The PV and buildings industries are beginning to work together to address issues including building codes and standards, integration, after-market servicing, education, and building energy efficiency. One of the most notable programs to encourage development of new PV-for-buildings products is the PV:BONUS program, supported by the US Department of Energy. Demand for these products from building designers has escalated since the program was initiated in 1993. This paper presents a range of PV-for-buildings issues and products that are currently influencing today's PV and buildings markets

  13. Superficiary Right of Building: Origin and Development in Central Europe

    Directory of Open Access Journals (Sweden)

    Petr Pavel

    2016-06-01

    Full Text Available The Czech Republic has been dealing for the last four years with a legal revolution in the field of private law. A new Civil Code was adopted in 2012 and many new and forgotten legal figures were restored in the text of the code. An interesting example of forgotten legal figures is the superficiary right of building, which has again entered the legal order of the Czech Republic after a long one hundred years. Unlike the Act on the Superficiary Right of Building of 1912, the new Civil Code extends the scope of persons that may create the superficiary right of building to their land. This should eliminate the obstacle that has substantially limited its wider use. The superficiary right of building is not likely to become a legal concept very frequently seen in public registers. The aim of this paper is, therefore, a reflection on divided ownership and the purpose and genesis of the superficiary right of building in relation to its origins, as well as a prediction of future developments of this legal concept in the real estate market. To analyse the concept, the paper employs formal and legal methods (logical, grammatical and historical method. A comparative study is conducted in the spirit of the comparative method. The superficiary right of building is a suitable complement to the range of options of property rights offered by the new Civil Code. The author concludes that the use of the superficiary right of building, although not limited in comparison with the 1912 Act, will likely be less frequent and focused on longer-term projects.

  14. Marketing of breast-milk substitutes in Zambia: evaluation of compliance to the international regulatory code.

    Science.gov (United States)

    Funduluka, P; Bosomprah, S; Chilengi, R; Mugode, R H; Bwembya, P A; Mudenda, B

    2018-03-01

    We sought to assess the level of non-compliance with the International Code of Marketing breast-milk substitutes (BMS) and/or Statutory Instrument (SI) Number 48 of 2006 of the Laws of Zambia in two suburbs, Kalingalinga and Chelstone, in Zambia. This was a cross sectional survey. Shop owners (80), health workers (8) and mothers (214) were interviewed. BMS labels and advertisements (62) were observed. The primary outcome was mean non-compliance defined as the number of article violations divided by the total 'obtainable' violations. The score ranges from 0 to 1 with 0 representing no violations in all the articles and one representing violations in all the articles. A total of 62 BMS were assessed. The mean non-compliance score by manufacturers in terms of violations in labelling of BMS was 0.33 (SD = 0.28; 95% CI: 0.26, 0.40). These violations were mainly due to labels containing pictures or graphics representing an infant. 80 shops were also assessed with mean non-compliance score in respect of violations in tie-in-sales, special display, and contact with mothers at the shop estimated as 0.14 (SD = 0.14; 95% CI: 0.11, 0.18). Non-compliance with the Code and/or the local SI is high after 10 years of domesticating the Code.

  15. Solar energy in buildings solved by building information modeling

    Science.gov (United States)

    Chudikova, B.; Faltejsek, M.

    2018-03-01

    Building lead us to use renewable energy sources for all types of buildings. The use of solar energy is the alternatives that can be applied in a good ratio of space, price, and resultant benefits. Building Information Modelling is a modern and effective way of dealing with buildings with regard to all aspects of the life cycle. The basis is careful planning and simulation in the pre-investment phase, where it is possible to determine the effective result and influence the lifetime of the building and the cost of its operation. By simulating, analysing and insert a building model into its future environment where climate conditions and surrounding buildings play a role, it is possible to predict the usability of the solar energy and establish an ideal model. Solar systems also very affect the internal layout of buildings. Pre-investment phase analysis, with a view to future aspects, will ensure that the resulting building will be both low-energy and environmentally friendly.

  16. The status of Korean nuclear codes and standards

    International Nuclear Information System (INIS)

    Namha Kim; Jong-Hae Kim

    2005-01-01

    Korea Electric Power Industry Code (KEPIC), a set of integrated standards applicable to the design, construction and operation of electric power facilities including nuclear power plants, has been developed on the basis of referring to the prevailing U.S. codes and standards which had been applied to the electric power facilities in Korea. Being the developing and managing organization of KEPIC, Korea Electric Association (KEA) published its first edition in 1995, the second in 200,0 and is expected to publish the 2005 edition. KEPIC was applied to the construction of Ulchin Nuclear Units 5 and 6 in 1997, and will be applicable to the construction of forthcoming nuclear power plants in Korea. Along with the effectuation of the Agreement on Technical Barriers to Trade (TBT) in 1995, the international trend related to codes and standards is changing rapidly. The KEA is, therefore, making its utmost efforts so as for KEPIC to keep abreast with the changing environment in international arena. KEA notified ISO/IEC Information Centre of its acceptance of the Code of Good Practice in the Agreement on TBT. The 2005 KEPIC edition will be retrofitted according to the ISO/IEC Guide 21- Adoption of International Standards as regional or national standards. KEA's efforts will help KEPIC correspond with international standards such as ISO/IEC standards, and internationally recognized standards such as ASME codes and standards. (authors)

  17. Compliance status of product labels to the international code on marketing of breast milk substitutes.

    Science.gov (United States)

    Ergin, Ahmet; Hatipoğlu, Celile; Bozkurt, Ali Ihsan; Erdoğan, Aslı; Güler, Serdar; Ince, Gülberat; Kavurgacı, Nuran; Oz, Ahmet; Yeniay, Mustafa K

    2013-01-01

    The aim of this study was to determine the compliance status of product labels regarding Article 9 of the International Code on Marketing of Breast-milk Substitutes (the Code) in Denizli province, Turkey. A cross-sectional study design was employed to determine the compliance status. The product labels were obtained from a convenience sample of five supermarkets, one store and 5 pharmacies in the City centre and district of Honaz. Using a data collection form prepared by previously published studies, data were collected between July 26, 2010 and August 06, 2010. Data collection form included 13 criteria. In addition, we checked the boxes for the availability of a Turkish written label. Forty product labels of 7 companies were reached and evaluated. These products consisted of 83.0% of the products marketed by these companies in Turkey. Thirty seven (92.5%) of the labels violated Article 9 of the Code in terms of one or more criteria. Thirty four (85.0%) of the labels had photos or pictures idealizing the use of infant formula. Nine (22.5%) had a photo, a picture or any representation of an infant, and five (12.5%) had text which idealize the use of infant formula or discouraging breastfeeding. Eight (20%) did not state that breastfeeding is the best. Four (10%) had a term such as 'similar to breast milk or human milk'. In conclusion, the majority of the product labels of breast milk substitutes marketed in our country violate the Code. It is appropriate that the Turkish Ministry of Health, medical organizations, companies, and NGOs work more actively to increase awareness of this issue.

  18. Analysis of the Explosive Internal Impact on the Barriers of Building Structures

    Science.gov (United States)

    Siwiński, Jarosław; Stolarski, Adam

    2017-10-01

    Work issues concern the safety of construction in relation to the hazards arising from explosion of the explosive charge located inside the building. The algorithms proposed in the paper for determining the parameters of the overpressure wave resulting from the detonation of clustered explosive charges, determine the basis for numerical simulation analyzes. Determination of the maximum value of peak pressure on the wave forehead of an internal explosion is presented on the basis of reflected wave analysis. Changeability in time of the internal explosion action describes the overpressure phase only. The analysis of the load caused by the internal explosive charge detonation was carried out under conditions of the undisturbed standard atmosphere. A load determination algorithm has been developed, taking into account the geometrical characteristics of the building barriers and the rooms as well as the parameters of environment in which the detonation occurs. The way of taking into account the influence of venting surfaces, i.e. windows, doors, ventilation ducts, on the overpressure wave parameters, was presented. Discloses a method to take into account the effect of the surface relief, i.e. windows, doors, air ducts, pressure wave parameters. Modification of the method for explosive overpressure determination presented by Cormie, Smith, Mays (2009), was proposed in the paper. This modification was developed on the basis of substitute impulse analysis for multiple overpressure pulses. In order to take into account the pressure distribution of explosive gases on the barrier surface, the method of modification the relationship for determination the changeability over time and space of the pressure of explosive gases, was presented. For this purpose, the changeability of the pressure wave angles of incidence to the barrier and the distance of the explosive charge to any point on the surface of the barrier, was taken into account. Based on the developed procedure, the

  19. Should International Classification of Diseases codes be used to survey hospital-acquired pneumonia?

    Science.gov (United States)

    Wolfensberger, A; Meier, A H; Kuster, S P; Mehra, T; Meier, M-T; Sax, H

    2018-05-01

    As surveillance of hospital-acquired pneumonia (HAP) is very resource intensive, alternatives for HAP surveillance are needed urgently. This study compared HAP rates according to routine discharge diagnostic codes of the International Classification of Diseases, 10 th Revision (ICD-10; ICD-HAP) with HAP rates according to the validated surveillance definitions of the Hospitals in Europe Link for Infection Control through Surveillance (HELICS/IPSE; HELICS-HAP) by manual retrospective re-evaluation of patient records. The positive predictive value of ICD-HAP for HELICS-HAP was 0.35, and sensitivity was 0.59. Therefore, the currently available ICD-10-based routine discharge data do not allow reliable identification of patients with HAP. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. Responses of a tall building with U.S. code-type instrumentation in Tokyo, Japan, to events before, during and after the Tohoku earthquake of 11 March 2011

    Science.gov (United States)

    Çelebi, Mehmet; Kashima, Toshihide; Ghahari, S. Farid; Abazarsa, Fariba; Taciroglu, Ertugrul

    2016-01-01

    The 11 March 2011 M 9.0 Tohoku earthquake generated long-duration shaking that propagated hundreds of kilometers from the epicenter and affected tall buildings in urban areas several hundred kilometers from the epicenter of the main shock. Recorded responses show that tall buildings were affected by long-period motions. This study presents the behavior and performance of a 37-story building in the Tsukuda area of Tokyo, Japan, as inferred from modal analyses of records retrieved for a time interval covering a few days before, during, and for several months after the main shock. The U.S. “code-type” array comprises three triaxial accelerometers deployed at three levels in the superstructure. Such a sparse array in a tall structure limits a reliable assessment, because its performance must be based on only the average drift ratios. Based on the inferred values of this parameter, the subject building was not structurally damaged.

  1. Compliance with the International Code of Marketing of breast-milk substitutes: an observational study of pediatricians' waiting rooms.

    Science.gov (United States)

    Dodgson, Joan E; Watkins, Amanda L; Bond, Angela B; Kintaro-Tagaloa, Cheryl; Arellano, Alondra; Allred, Patrick A

    2014-04-01

    Abstract The importance of breastmilk as a primary preventative intervention is widely known and understood by most healthcare providers. The actions or non-actions that heathcare providers take toward promoting and supporting breastfeeding families make a difference in the success and duration of breastfeeding. Recognizing this relationship, the World Health Organization developed the International Code of Marketing of Breast-milk Substitutes (the Code), which defines best practices in breastfeeding promotion, including physicians' offices. The pediatric practices' waiting rooms are often a family's first experience with pediatric care. The specific aims of this study were to describe (1) Code compliance, (2) the demographic factors affecting the Code compliance, and (3) the amount and type of breastfeeding-supportive materials available in the pediatricians' waiting rooms. An observational cross-sectional design was used to collect data from 163 (82%) of the pediatric practices in Maricopa County, Arizona. None of the 100 waiting rooms that had any materials displayed (61%) was found to be completely Code compliant, with 81 of the offices having formula-promotional materials readily available. Waiting rooms in higher income areas offered more non-Code-compliant materials and gifts. Breastfeeding support information and materials were lacking in all but 18 (18%) offices. A positive relationship (t97=-2.31, p=0.02) occurred between the presence of breastfeeding educational materials and higher income areas. We were able to uncover some practice-related patterns that impact families and potentially undermine breastfeeding success. To move current practices toward breastfeeding-friendly physicians' offices, change is needed.

  2. Review of codes, standards, and regulations for natural gas locomotives.

    Science.gov (United States)

    2014-06-01

    This report identified, collected, and summarized relevant international codes, standards, and regulations with potential : applicability to the use of natural gas as a locomotive fuel. Few international or country-specific codes, standards, and regu...

  3. Microdosimetry computation code of internal sources - MICRODOSE 1

    International Nuclear Information System (INIS)

    Li Weibo; Zheng Wenzhong; Ye Changqing

    1995-01-01

    This paper describes a microdosimetry computation code, MICRODOSE 1, on the basis of the following described methods: (1) the method of calculating f 1 (z) for charged particle in the unit density tissues; (2) the method of calculating f(z) for a point source; (3) the method of applying the Fourier transform theory to the calculation of the compound Poisson process; (4) the method of using fast Fourier transform technique to determine f(z) and, giving some computed examples based on the code, MICRODOSE 1, including alpha particles emitted from 239 Pu in the alveolar lung tissues and from radon progeny RaA and RAC in the human respiratory tract. (author). 13 refs., 6 figs

  4. System Design Description for the TMAD Code

    International Nuclear Information System (INIS)

    Finfrock, S.H.

    1995-01-01

    This document serves as the System Design Description (SDD) for the TMAD Code System, which includes the TMAD code and the LIBMAKR code. The SDD provides a detailed description of the theory behind the code, and the implementation of that theory. It is essential for anyone who is attempting to review or modify the code or who otherwise needs to understand the internal workings of the code. In addition, this document includes, in Appendix A, the System Requirements Specification for the TMAD System

  5. CONTRANS 2 code conversion from Apollo to HP

    International Nuclear Information System (INIS)

    Lee, Hae Cho

    1996-01-01

    CONTRANS2 computer code is used to calculate transient thermal hydraulic responses of containment building to loss of coolant and main steam line break accident. Mass and energy release to the containment following an accident are code inputs. This report firstly describes detailed work carried out for installation of CONTRANS2 on Apollo DN10000 and code validation results after installation. Secondly, A series of work is also describes in relation to installation of CONTRANS2 on HP 9000/700 series as well as relevant code validation results. Attached is a report on software verification and validation results. 7 refs. (Author) .new

  6. ETR/ITER systems code

    Energy Technology Data Exchange (ETDEWEB)

    Barr, W.L.; Bathke, C.G.; Brooks, J.N.; Bulmer, R.H.; Busigin, A.; DuBois, P.F.; Fenstermacher, M.E.; Fink, J.; Finn, P.A.; Galambos, J.D.; Gohar, Y.; Gorker, G.E.; Haines, J.R.; Hassanein, A.M.; Hicks, D.R.; Ho, S.K.; Kalsi, S.S.; Kalyanam, K.M.; Kerns, J.A.; Lee, J.D.; Miller, J.R.; Miller, R.L.; Myall, J.O.; Peng, Y-K.M.; Perkins, L.J.; Spampinato, P.T.; Strickler, D.J.; Thomson, S.L.; Wagner, C.E.; Willms, R.S.; Reid, R.L. (ed.)

    1988-04-01

    A tokamak systems code capable of modeling experimental test reactors has been developed and is described in this document. The code, named TETRA (for Tokamak Engineering Test Reactor Analysis), consists of a series of modules, each describing a tokamak system or component, controlled by an optimizer/driver. This code development was a national effort in that the modules were contributed by members of the fusion community and integrated into a code by the Fusion Engineering Design Center. The code has been checked out on the Cray computers at the National Magnetic Fusion Energy Computing Center and has satisfactorily simulated the Tokamak Ignition/Burn Experimental Reactor II (TIBER) design. A feature of this code is the ability to perform optimization studies through the use of a numerical software package, which iterates prescribed variables to satisfy a set of prescribed equations or constraints. This code will be used to perform sensitivity studies for the proposed International Thermonuclear Experimental Reactor (ITER). 22 figs., 29 tabs.

  7. ETR/ITER systems code

    International Nuclear Information System (INIS)

    Barr, W.L.; Bathke, C.G.; Brooks, J.N.

    1988-04-01

    A tokamak systems code capable of modeling experimental test reactors has been developed and is described in this document. The code, named TETRA (for Tokamak Engineering Test Reactor Analysis), consists of a series of modules, each describing a tokamak system or component, controlled by an optimizer/driver. This code development was a national effort in that the modules were contributed by members of the fusion community and integrated into a code by the Fusion Engineering Design Center. The code has been checked out on the Cray computers at the National Magnetic Fusion Energy Computing Center and has satisfactorily simulated the Tokamak Ignition/Burn Experimental Reactor II (TIBER) design. A feature of this code is the ability to perform optimization studies through the use of a numerical software package, which iterates prescribed variables to satisfy a set of prescribed equations or constraints. This code will be used to perform sensitivity studies for the proposed International Thermonuclear Experimental Reactor (ITER). 22 figs., 29 tabs

  8. International common-cause failure data exchange. ICDE general coding guidelines - Technical note

    International Nuclear Information System (INIS)

    Johanson, Gunnar; Werner, Wolfgang; Concepcion Capote, Marina; Kreuser, Albert; Rasmuson, Dale; Jonsson, Esther; Pereira Pagan, Begona; Tirira, Jorge; Morris, Ian; Morales, Rosa; Oxberry, Anna; Kreuser, Albert

    2004-01-01

    Several Member countries of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA) have established the International Common-Cause Failure Data Exchange Project (ICDE Project) to encourage multilateral co-operation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The objectives of the ICDE Project are to: a) Collect and analyse CCF events over the long term so as to better understand such events, their causes, and their prevention; b) Generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences; c) Establish a mechanism for the efficient feedback of experience gained in connection with CCF phenomena, including the development of defences against their occurrence, such as indicators for risk based inspections; and d) Record event attributes to facilitate quantification of CCF frequencies when so decided by the Project Working Group. The ICDE Project is envisaged to comprise all possible events of interest, including both complete and partial ICDE events. The ICDE Project will cover the key components of the main safety systems. Presently, the components listed below are included in the ICDE Project. Data have been collected for the six first components in the list: Centrifugal pumps, Diesel generators, Motor operated valves, Safety relief valves/power operated relief valves, Check valves, Batteries, Level measurement, Breakers, Control rod drive assemblies. Others will be added to this list later on. In this component coding guidelines, explanations on the ICDE General coding format are given. The guide reflects present experience with the data format and with the collected data. Further interpretations and clarifications will be added, should they become necessary. For each component analysed in the ICDE project, separate coding guidance is provided in the appendices

  9. Energy efficiency drivers in Europe. Regulations and other instruments open new horizons for energy management in buildings

    International Nuclear Information System (INIS)

    Obara, H.

    2010-01-01

    Curbing climate change and global warming will be one of the major challenges of the 21. Century.The very survival of our society could be at stake. Greenhouse gases including CO 2 have been identified as the culprits and the vast majority of industrialized countries have agreed to cut emissions drastically over coming decades. Buildings account for nearly 40% of the energy used in most countries and are responsible for a similar level of global CO 2 emissions. Energy efficiency in buildings is therefore one of the keys to reducing green-house emissions. The main driving force to achieve the ambitious goals that have been set for the reduction of greenhouse gases will come from energy efficiency regulations, building codes, standards, labels, certifications, obligations and incentives, all of which have been multiplying steadily over recent decades. International institutions are rolling out energy efficiency directives and standards that set minimum requirements for buildings.They are gradually being taken into account in national regulations and building codes. Today, most energy efficiency regulations concern building design. They hardly touch on Energy Management aspects that can generate major operational gains with relatively low investments and quick payback. Beyond regulations that focus on minimum requirements, environmental performance labels use building rating criteria that can take energy efficiency much further.They offer a practical way of assigning value to energy efficiency and in this way represent powerful market drivers. Moreover, the important benefits of Energy Management can be easily integrated in the rating criteria of these far-reaching schemes. Indeed, through effective building measurement, monitoring and control systems, Energy Management is one of the keys to rapidly reducing carbon emissions and achieving climate change targets. (author)

  10. Defining a Communications Satellite Policy System for the 21st Century: A Model for a International Legal Framework and A New _Code of Conduct_

    Science.gov (United States)

    Pelton, Joseph N.

    1996-02-01

    This paper addresses the changing international communications environment and explores the key elements of a new policy framework for the 21st Century. It addresses the issues related to changing markets, trade considerations, standards, regulatory changes and international institutions and law. The most important aspects will related to new international policy and regulatory frameworks and in particular to a new international code of ethics and behavior in the field of satellite communications. A new communications satellite policy framework requires systematically addressing the following points: • Multi-lateral agreements at the nation state and the operating entity level • Systematic means to access both private and public capital • Meshing ITU regulations with regional and national policy guidelines including • landing rights" and national allocation procedures. • Systematic approach to local partnerships • Resolving the issue of the relative standing of various satellite systems (i.e. GEO, MEO, and LEO systems) • Resolving the rights, duties, and priorities of satellite facility providers versus types of service prviders. Beyond this policy framework and generalized legal infrastructure there is also another need. This is a need that arises from both increased globalism and competitive international markets. This is what might quite simply be called a "code of reasonable conduct:" To provide global and international communications services effectively and well in the 21st Century will require more than meeting minimum international legal requirements. A new "code of conduct" for global satellite communications will thus likely need to address: • Privacy and surveillance • Ethics of transborder data flow • Censorship and moral values • Cultural and linguistic sensitivity • Freedom of the press and respect for journalistic standards As expanding global information and telecommunications systems grow and impact every aspect of modern

  11. Numerical simulation of solar heating of buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Coffe, G.; Jannot, M.; Pellerin, J.F.

    1980-01-01

    This study is divided into two parts: First, the thermal modelling of a solar + electric heated building is presented; mathematical equations are established; numerical calculations are analyzed; and a calculation code in FORTRAN V is set down. Second, this calculation code was used to study the thermal performances of the solar + electric heated building in three European climates: Copenhagen (56/sup 0/ north latitude - Denmark), Trappes (48/sup 0/ north latitude - France), and Carpentras (44/sup 0/ north latitude - France).

  12. Inclusion of models to describe severe accident conditions in the fuel simulation code DIONISIO

    Energy Technology Data Exchange (ETDEWEB)

    Lemes, Martín; Soba, Alejandro [Sección Códigos y Modelos, Gerencia Ciclo del Combustible Nuclear, Comisión Nacional de Energía Atómica, Avenida General Paz 1499, 1650 San Martín, Provincia de Buenos Aires (Argentina); Daverio, Hernando [Gerencia Reactores y Centrales Nucleares, Comisión Nacional de Energía Atómica, Avenida General Paz 1499, 1650 San Martín, Provincia de Buenos Aires (Argentina); Denis, Alicia [Sección Códigos y Modelos, Gerencia Ciclo del Combustible Nuclear, Comisión Nacional de Energía Atómica, Avenida General Paz 1499, 1650 San Martín, Provincia de Buenos Aires (Argentina)

    2017-04-15

    The simulation of fuel rod behavior is a complex task that demands not only accurate models to describe the numerous phenomena occurring in the pellet, cladding and internal rod atmosphere but also an adequate interconnection between them. In the last years several models have been incorporated to the DIONISIO code with the purpose of increasing its precision and reliability. After the regrettable events at Fukushima, the need for codes capable of simulating nuclear fuels under accident conditions has come forth. Heat removal occurs in a quite different way than during normal operation and this fact determines a completely new set of conditions for the fuel materials. A detailed description of the different regimes the coolant may exhibit in such a wide variety of scenarios requires a thermal-hydraulic formulation not suitable to be included in a fuel performance code. Moreover, there exist a number of reliable and famous codes that perform this task. Nevertheless, and keeping in mind the purpose of building a code focused on the fuel behavior, a subroutine was developed for the DIONISIO code that performs a simplified analysis of the coolant in a PWR, restricted to the more representative situations and provides to the fuel simulation the boundary conditions necessary to reproduce accidental situations. In the present work this subroutine is described and the results of different comparisons with experimental data and with thermal-hydraulic codes are offered. It is verified that, in spite of its comparative simplicity, the predictions of this module of DIONISIO do not differ significantly from those of the specific, complex codes.

  13. Development of 'SKYSHINE-CG' code. A line-beam method code equipped with combinatorial geometry routine

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Takahiro; Ochiai, Katsuharu [Plant and System Planning Department, Toshiba Corporation, Yokohama, Kanagawa (Japan); Uematsu, Mikio; Hayashida, Yoshihisa [Department of Nuclear Engineering, Toshiba Engineering Corporation, Yokohama, Kanagawa (Japan)

    2000-03-01

    A boiling water reactor (BWR) plant has a single loop coolant system, in which main steam generated in the reactor core proceeds directly into turbines. Consequently, radioactive {sup 16}N (6.2 MeV photon emitter) contained in the steam contributes to gamma-ray skyshine dose in the vicinity of the BWR plant. The skyshine dose analysis is generally performed with the line-beam method code SKYSHINE, in which calculational geometry consists of a rectangular turbine building and a set of isotropic point sources corresponding to an actual distribution of {sup 16}N sources. For the purpose of upgrading calculational accuracy, the SKYSHINE-CG code has been developed by incorporating the combinatorial geometry (CG) routine into the SKYSHINE code, so that shielding effect of in-building equipment can be properly considered using a three-dimensional model composed of boxes, cylinders, spheres, etc. Skyshine dose rate around a 500 MWe BWR plant was calculated with both SKYSHINE and SKYSHINE-CG codes, and the calculated results were compared with measured data obtained with a NaI(Tl) scintillation detector. The C/E values for SKYSHINE-CG calculation were scattered around 4.0, whereas the ones for SKYSHINE calculation were as large as 6.0. Calculational error was found to be reduced by adopting three-dimensional model based on the combinatorial geometry method. (author)

  14. Insurance billing and coding.

    Science.gov (United States)

    Napier, Rebecca H; Bruelheide, Lori S; Demann, Eric T K; Haug, Richard H

    2008-07-01

    The purpose of this article is to highlight the importance of understanding various numeric and alpha-numeric codes for accurately billing dental and medically related services to private pay or third-party insurance carriers. In the United States, common dental terminology (CDT) codes are most commonly used by dentists to submit claims, whereas current procedural terminology (CPT) and International Classification of Diseases, Ninth Revision, Clinical Modification (ICD.9.CM) codes are more commonly used by physicians to bill for their services. The CPT and ICD.9.CM coding systems complement each other in that CPT codes provide the procedure and service information and ICD.9.CM codes provide the reason or rationale for a particular procedure or service. These codes are more commonly used for "medical necessity" determinations, and general dentists and specialists who routinely perform care, including trauma-related care, biopsies, and dental treatment as a result of or in anticipation of a cancer-related treatment, are likely to use these codes. Claim submissions for care provided can be completed electronically or by means of paper forms.

  15. The accuracy of International Classification of Diseases coding for dental problems not associated with trauma in a hospital emergency department.

    Science.gov (United States)

    Figueiredo, Rafael L F; Singhal, Sonica; Dempster, Laura; Hwang, Stephen W; Quinonez, Carlos

    2015-01-01

    Emergency department (ED) visits for nontraumatic dental conditions (NTDCs) may be a sign of unmet need for dental care. The objective of this study was to determine the accuracy of the International Classification of Diseases codes (ICD-10-CA) for ED visits for NTDC. ED visits in 2008-2099 at one hospital in Toronto were identified if the discharge diagnosis in the administrative database system was an ICD-10-CA code for a NTDC (K00-K14). A random sample of 100 visits was selected, and the medical records for these visits were reviewed by a dentist. The description of the clinical signs and symptoms were evaluated, and a diagnosis was assigned. This diagnosis was compared with the diagnosis assigned by the physician and the code assigned to the visit. The 100 ED visits reviewed were associated with 16 different ICD-10-CA codes for NTDC. Only 2 percent of these visits were clearly caused by trauma. The code K0887 (toothache) was the most frequent diagnostic code (31 percent). We found 43.3 percent disagreement on the discharge diagnosis reported by the physician, and 58.0 percent disagreement on the code in the administrative database assigned by the abstractor, compared with what it was suggested by the dentist reviewing the chart. There are substantial discrepancies between the ICD-10-CA diagnosis assigned in administrative databases and the diagnosis assigned by a dentist reviewing the chart retrospectively. However, ICD-10-CA codes can be used to accurately identify ED visits for NTDC. © 2015 American Association of Public Health Dentistry.

  16. Using Administrative Mental Health Indicators in Heart Failure Outcomes Research: Comparison of Clinical Records and International Classification of Disease Coding.

    Science.gov (United States)

    Bender, Miriam; Smith, Tyler C

    2016-01-01

    Use of mental indication in health outcomes research is of growing interest to researchers. This study, as part of a larger research program, quantified agreement between administrative International Classification of Disease (ICD-9) coding for, and "gold standard" clinician documentation of, mental health issues (MHIs) in hospitalized heart failure (HF) patients to determine the validity of mental health administrative data for use in HF outcomes research. A 13% random sample (n = 504) was selected from all unique patients (n = 3,769) hospitalized with a primary HF diagnosis at 4 San Diego County community hospitals during 2009-2012. MHI was defined as ICD-9 discharge diagnostic coding 290-319. Records were audited for clinician documentation of MHI. A total of 43% (n = 216) had mental health clinician documentation; 33% (n = 164) had ICD-9 coding for MHI. ICD-9 code bundle 290-319 had 0.70 sensitivity, 0.97 specificity, and kappa 0.69 (95% confidence interval 0.61-0.79). More specific ICD-9 MHI code bundles had kappas ranging from 0.44 to 0.82 and sensitivities ranging from 42% to 82%. Agreement between ICD-9 coding and clinician documentation for a broadly defined MHI is substantial, and can validly "rule in" MHI for hospitalized patients with heart failure. More specific MHI code bundles had fair to almost perfect agreement, with a wide range of sensitivities for identifying patients with an MHI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Report on corrections and future considerations for Appendices II–VIII of the International Code of Nomenclature for Algae, Fungi, and Plants

    Science.gov (United States)

    For the first time, the main text and Appendices II–VIII of the International Code of Nomenclature were separately published following decisions of the Melbourne Nomenclature Section, which contributed to subsequent development of an online resource capable of producing the Appendices in real time. ...

  18. Fire safety of historical buildings traditional versus innovative “behavioural design” solutions by using wayfinding systems

    CERN Document Server

    Bernardini, Gabriele

    2017-01-01

    This book applies a behavioral point of view to individuals’ fire safety in historic buildings. It outlines theoretical and operative issues, based on recent studies and international guidelines. Firstly, critical issues for Building Heritage fire safety are widely discussed, by including the modelling of human factor and man-environment-fire interference in these architectural spaces. A significant part of the book includes a discussion on emergency modeling and simulation. A source code for representing the fire evacuation process (including man-evacuation facilities interactions) is offered to the reader. Methods for effectiveness assessment of risk-reducing solutions are provided and tested in a case-study. Being a structured approach to occupants-related problems during a fire in heritage buildings, it offers an innovative methodology and practical examples that researchers and designers can use as a guide when proposing and testing solutions. Evaluation indexes for effectiveness assessment (also usefu...

  19. Assessment Framework of Building Facade in Optimizing Indoor Thermal Comfort of Green Building Index (GBI Certified Office Building

    Directory of Open Access Journals (Sweden)

    Abdul Tharim Asniza Hamimi

    2016-01-01

    Full Text Available During the past decade, the construction industry has seen a new trend in the development of “green” or “sustainable” construction concept around the world with vast support from prominent organization, together with the introduction of sustainable building codes. The establishment of green building certification systems worldwide is seen as one of the most efforts in the emerging green building movement. In order to support the development of the “green” and “sustainable” concept in Malaysia, Green Building Index (GBI was launched by the government on 21 May 2009 that created to promote sustainability in the built environment and raise awareness of environmental issues. However, the construction industry seems to have focused only on findings the “right mechanism” for an environmentally sustainable “final result” in order for the building to be certified as green with the lacking of continuous assessment on the building performance after the certifications. This study is purposely conducted to investigate the performance of various rated Green Building Index (GBI Non-Residential New Construction office buildings and the influence on Indoor Thermal Comfort (ITC of the selected buildings. The aim is to develop an assessment framework for optimum green building architectural façade to be used for office buildings in Malaysia as well as to analyse the occupants’ perception, satisfaction and performance in the selected Green Building Index (GBI rated office indoor environment. This research is still in its infancy; therefore the paper is focused on research aims, research scope and methodology, and expected deliverables for the proposed research.

  20. Revision of the recommended international general standard for irradiated foods and of the recommended international code of practice for the operation of radiation facilities used for the treatment of foods

    International Nuclear Information System (INIS)

    1981-11-01

    In view of the findings and statements of the Joint FAO/IAEA/WHO Expert Committee on the Wholesomeness of Irradiated Food, convened in Geneva from 27 October to 3 November 1980, a Consultation Group, convened in Geneva from 1 to 3 July 1981 suggested the revision of the Recommended International General Standard for Irradiated Foods and of the Recommended International Code of Practice for the Operation of Radiation Facilities. The proposed changes are given and justified and the revised wording of the documents presented

  1. Nation-building e segurança internacional: Um debate em construção Nation-building and international security: A debate under construction

    Directory of Open Access Journals (Sweden)

    Aureo de Toledo Gomes

    2009-08-01

    Full Text Available Este artigo almeja analisar as operações de nation-building, que, desde os atentados terroristas de 11 de setembro de 2001, são consideradas uma das maneiras para se lidar com as novas ameaças de segurança internacional, principalmente os ditos Estados Falidos. Assim sendo, revisaremos a bibliografia sobre o tema, procurando identificar as origens destas operações, assim como as definições utilizadas pelos principais autores e os problemas que elas possam apresentar.This article aims to analyze nation-building operations, which have been considered, since September 11, 2001 terrorist attacks, one of the ways to cope with the new threats to international security, mainly the so-called Failed States. Therefore, we will review the bibliography published, trying to identity not only the origins of such operations but also the definitions used by the main authors and the problems that they might present.

  2. Identifying Adverse Events Using International Classification of Diseases, Tenth Revision Y Codes in Korea: A Cross-sectional Study

    Directory of Open Access Journals (Sweden)

    Minsu Ock

    2018-01-01

    Full Text Available Objectives The use of administrative data is an affordable alternative to conducting a difficult large-scale medical-record review to estimate the scale of adverse events. We identified adverse events from 2002 to 2013 on the national level in Korea, using International Classification of Diseases, tenth revision (ICD-10 Y codes. Methods We used data from the National Health Insurance Service-National Sample Cohort (NHIS-NSC. We relied on medical treatment databases to extract information on ICD-10 Y codes from each participant in the NHIS-NSC. We classified adverse events in the ICD-10 Y codes into 6 types: those related to drugs, transfusions, and fluids; those related to vaccines and immunoglobulin; those related to surgery and procedures; those related to infections; those related to devices; and others. Results Over 12 years, a total of 20 817 adverse events were identified using ICD-10 Y codes, and the estimated total adverse event rate was 0.20%. Between 2002 and 2013, the total number of such events increased by 131.3%, from 1366 in 2002 to 3159 in 2013. The total rate increased by 103.9%, from 0.17% in 2002 to 0.35% in 2013. Events related to drugs, transfusions, and fluids were the most common (19 446, 93.4%, followed by those related to surgery and procedures (1209, 5.8% and those related to vaccines and immunoglobulin (72, 0.3%. Conclusions Based on a comparison with the results of other studies, the total adverse event rate in this study was significantly underestimated. Improving coding practices for ICD-10 Y codes is necessary to precisely monitor the scale of adverse events in Korea.

  3. Internal radiation dose calculations with the INREM II computer code

    International Nuclear Information System (INIS)

    Dunning, D.E. Jr.; Killough, G.G.

    1978-01-01

    A computer code, INREM II, was developed to calculate the internal radiation dose equivalent to organs of man which results from the intake of a radionuclide by inhalation or ingestion. Deposition and removal of radioactivity from the respiratory tract is represented by the Internal Commission on Radiological Protection Task Group Lung Model. A four-segment catenary model of the gastrointestinal tract is used to estimate movement of radioactive material that is ingested, or swallowed after being cleared from the respiratory tract. Retention of radioactivity in other organs is specified by linear combinations of decaying exponential functions. The formation and decay of radioactive daughters is treated explicitly, with each radionuclide in the decay chain having its own uptake and retention parameters, as supplied by the user. The dose equivalent to a target organ is computed as the sum of contributions from each source organ in which radioactivity is assumed to be situated. This calculation utilizes a matrix of dosimetric S-factors (rem/μCi-day) supplied by the user for the particular choice of source and target organs. Output permits the evaluation of components of dose from cross-irradiations when penetrating radiations are present. INREM II has been utilized with current radioactive decay data and metabolic models to produce extensive tabulations of dose conversion factors for a reference adult for approximately 150 radionuclides of interest in environmental assessments of light-water-reactor fuel cycles. These dose conversion factors represent the 50-year dose commitment per microcurie intake of a given radionuclide for 22target organs including contributions from specified source organs and surplus activity in the rest of the body. These tabulations are particularly significant in their consistent use of contemporary models and data and in the detail of documentation

  4. Building and Testing with Gradle

    CERN Document Server

    Berglund, Tim

    2011-01-01

    Build and test software written in Java and many other languages with Gradle, the open source project automation tool that's getting a lot of attention. This concise introduction provides numerous code examples to help you explore Gradle, both as a build tool and as a complete solution for automating the compilation, test, and release process of simple and enterprise-level applications. Discover how Gradle improves on the best ideas of Ant, Maven, and other build tools, with standards for developers who want them and lots of flexibility for those who prefer less structure. Use Gradle with Gr

  5. Heap leach cyanide irrigation and risk to wildlife: Ramifications for the international cyanide management code.

    Science.gov (United States)

    Donato, D B; Madden-Hallett, D M; Smith, G B; Gursansky, W

    2017-06-01

    Exposed cyanide-bearing solutions associated with gold and silver recovery processes in the mining industry pose a risk to wildlife that interact with these solutions. This has been documented with cyanide-bearing tailings storage facilities, however risks associated with heap leach facilities are poorly documented, monitored and audited. Gold and silver leaching heap leach facilities use cyanide, pH-stabilised, at concentrations deemed toxic to wildlife. Their design and management are known to result in exposed cyanide-bearing solutions that are accessible to and present a risk to wildlife. Monitoring of the presence of exposed solutions, wildlife interaction, interpretation of risks and associated wildlife deaths are poorly documented. This paper provides a list of critical monitoring criteria and attempts to predict wildlife guilds most at risk. Understanding the significance of risks to wildlife from exposed cyanide solutions is complex, involving seasonality, relative position of ponding, temporal nature of ponding, solution palatability, environmental conditions, in situ wildlife species inventory and provision of alternative drinking sources for wildlife. Although a number of heap leach operations are certified as complaint with the International Cyanide Management Code (Cyanide Code), these criteria are not considered by auditors nor has systematic monitoring regime data been published. Without systematic monitoring and further knowledge, wildlife deaths on heap leach facilities are likely to remain largely unrecorded. This has ramifications for those operations certified as compliance with the Cyanide Code. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Analysis of the Chinese Market for Building Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Evans, Meredydd [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Shi, Qing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-03-20

    China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies on building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components

  7. Conceptual-driven classification for coding advise in health insurance reimbursement.

    Science.gov (United States)

    Li, Sheng-Tun; Chen, Chih-Chuan; Huang, Fernando

    2011-01-01

    With the non-stop increases in medical treatment fees, the economic survival of a hospital in Taiwan relies on the reimbursements received from the Bureau of National Health Insurance, which in turn depend on the accuracy and completeness of the content of the discharge summaries as well as the correctness of their International Classification of Diseases (ICD) codes. The purpose of this research is to enforce the entire disease classification framework by supporting disease classification specialists in the coding process. This study developed an ICD code advisory system (ICD-AS) that performed knowledge discovery from discharge summaries and suggested ICD codes. Natural language processing and information retrieval techniques based on Zipf's Law were applied to process the content of discharge summaries, and fuzzy formal concept analysis was used to analyze and represent the relationships between the medical terms identified by MeSH. In addition, a certainty factor used as reference during the coding process was calculated to account for uncertainty and strengthen the credibility of the outcome. Two sets of 360 and 2579 textual discharge summaries of patients suffering from cerebrovascular disease was processed to build up ICD-AS and to evaluate the prediction performance. A number of experiments were conducted to investigate the impact of system parameters on accuracy and compare the proposed model to traditional classification techniques including linear-kernel support vector machines. The comparison results showed that the proposed system achieves the better overall performance in terms of several measures. In addition, some useful implication rules were obtained, which improve comprehension of the field of cerebrovascular disease and give insights to the relationships between relevant medical terms. Our system contributes valuable guidance to disease classification specialists in the process of coding discharge summaries, which consequently brings benefits in

  8. Automation of Geometry Input for Building Code Compliance Check

    DEFF Research Database (Denmark)

    Petrova, Ekaterina Aleksandrova; Johansen, Peter Lind; Jensen, Rasmus Lund

    2017-01-01

    . That has left the industry in constant pursuit of possibilities for integration of the tool within the Building Information Modelling environment so that the potential provided by the latter can be harvested and the processed can be optimized. This paper presents a solution for automated data extraction...

  9. Fuel performance analysis code 'FAIR'

    International Nuclear Information System (INIS)

    Swami Prasad, P.; Dutta, B.K.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1994-01-01

    For modelling nuclear reactor fuel rod behaviour of water cooled reactors under severe power maneuvering and high burnups, a mechanistic fuel performance analysis code FAIR has been developed. The code incorporates finite element based thermomechanical module, physically based fission gas release module and relevant models for modelling fuel related phenomena, such as, pellet cracking, densification and swelling, radial flux redistribution across the pellet due to the build up of plutonium near the pellet surface, pellet clad mechanical interaction/stress corrosion cracking (PCMI/SSC) failure of sheath etc. The code follows the established principles of fuel rod analysis programmes, such as coupling of thermal and mechanical solutions along with the fission gas release calculations, analysing different axial segments of fuel rod simultaneously, providing means for performing local analysis such as clad ridging analysis etc. The modular nature of the code offers flexibility in affecting modifications easily to the code for modelling MOX fuels and thorium based fuels. For performing analysis of fuel rods subjected to very long power histories within a reasonable amount of time, the code has been parallelised and is commissioned on the ANUPAM parallel processing system developed at Bhabha Atomic Research Centre (BARC). (author). 37 refs

  10. A method for modeling co-occurrence propensity of clinical codes with application to ICD-10-PCS auto-coding.

    Science.gov (United States)

    Subotin, Michael; Davis, Anthony R

    2016-09-01

    Natural language processing methods for medical auto-coding, or automatic generation of medical billing codes from electronic health records, generally assign each code independently of the others. They may thus assign codes for closely related procedures or diagnoses to the same document, even when they do not tend to occur together in practice, simply because the right choice can be difficult to infer from the clinical narrative. We propose a method that injects awareness of the propensities for code co-occurrence into this process. First, a model is trained to estimate the conditional probability that one code is assigned by a human coder, given than another code is known to have been assigned to the same document. Then, at runtime, an iterative algorithm is used to apply this model to the output of an existing statistical auto-coder to modify the confidence scores of the codes. We tested this method in combination with a primary auto-coder for International Statistical Classification of Diseases-10 procedure codes, achieving a 12% relative improvement in F-score over the primary auto-coder baseline. The proposed method can be used, with appropriate features, in combination with any auto-coder that generates codes with different levels of confidence. The promising results obtained for International Statistical Classification of Diseases-10 procedure codes suggest that the proposed method may have wider applications in auto-coding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Progress towards the specification of embodied energy performance criteria for New Zealand buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baird, G.; Alcorn, A.; Wood, P.; Storey, J. B. [Victoria Univ., Wellington (New Zealand). School of Architecture; Jaques, R. [Building Research Association of New Zealand, Inc. (New Zealand)

    1998-11-01

    Incorporation of embodied energy performance criteria into New Zealand`s recently adopted performance-based building code is discussed. The paper also describes the concept of the Building Code and its energy related clauses and standards, work done to date to update the building materials` energy coefficients, and the progress made in using an embodied energy database. The purpose, desirability and likely pitfalls of such criteria, ways of specifying minimum performance, and relationships with operating energy criteria are also reviewed.

  12. Code of Conduct on the Safety of Research Reactors

    International Nuclear Information System (INIS)

    2006-09-01

    The Board of Governors of the International Atomic Energy Agency (IAEA) adopted the Code of Conduct on the Safety of Research Reactors on 8 March 2004. The Board's action was the culmination of several years of work to develop the Code and obtain a consensus on its provisions. The process leading to the Code began in 1998, when the International Nuclear Safety Advisory Group (INSAG) informed the Director General of concerns about the safety of research reactors. In 2000, INSAG recommended that the Secretariat begin developing an international protocol or a similar legal instrument to address those concerns. In September 2000, in resolution GC(44)/RES/14, the General Conference requested the Secretariat ''within its available resources, to continue work on exploring options to strengthen the international nuclear safety arrangements for civil research reactors, taking due account of input from INSAG and the views of other relevant bodies''. A working group convened by the Secretariat pursuant to that request recommended that ''the Agency consider establishing an international action plan for research reactors'' and that the action plan include preparation of a Code of Conduct ''that would clearly establish the desirable attributes for management of research reactor safety''. In September 2001, the Board requested that the Secretariat develop and implement, in conjunction with Member States, an international research reactor safety enhancement plan which included preparation of a Code of Conduct on the Safety of Research Reactors. Subsequently, in resolution GC(45)/RES/10.A, the General Conference endorsed the Board's request. Pursuant to that request, a Code of Conduct on the Safety of Research Reactors was drafted at two meetings of an Open-ended Working Group of Legal and Technical Experts. This draft Code of Conduct was circulated to all Member States for comment. On the basis of the responses received, a revised draft of the Code was prepared by the Secretariat

  13. Control buildings for blast resistance

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.A.

    1982-08-01

    Offers advice on interior design for blast-resistant control buildings. Suggests that for the comfort and safety of occupants, special attention must be paid to internal finishes and color schemes. Considers external treatment (e.g. panels, cladding fixings, thermal insulation), air intakes and exhausts, internal finishes (e.g. stud lining method), and internal walls and partitions. Presents diagrams showing construction method for a control building; elimination of ''cold bridge'' at eaves level; staggering door openings to minimize blast effects; and flexure of concrete walls without affecting the inner lining.

  14. Influence of internal thermal mass on the indoor thermal dynamics and integration of phase change materials in furniture for building energy storage

    DEFF Research Database (Denmark)

    Johra, Hicham; Heiselberg, Per Kvols

    2017-01-01

    The increasing share of intermittent renewable energy on the grid encourages researchers to develop demand-side management strategies. Passive heat storage in the indoor space is a promising solution to improve the building energy flexibility. It relies on an accurate control of the transient...... building temperature. However, many of the current numerical models for building energy systems assume empty rooms and do not account entirely for the internal thermal inertia of objects like furniture. This review article points out that such assumption is not valid for dynamic calculations...

  15. 2013 Building Technologies Office Program Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-11-01

    The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.

  16. 77 FR 26647 - National Building Safety Month, 2012

    Science.gov (United States)

    2012-05-04

    ... implementing state-of-the-art building safety, energy efficiency, and fire prevention codes and standards, they... our Nation's ability to withstand the threats and hazards we face. My Administration is committed to... disasters. We are drawing upon cutting edge science and technology to establish stronger codes and standards...

  17. The HART II International Workshop: An Assessment of the State-of-the-Art in Comprehensive Code Prediction

    Science.gov (United States)

    vanderWall, Berend G.; Lim, Joon W.; Smith, Marilyn J.; Jung, Sung N.; Bailly, Joelle; Baeder, James D.; Boyd, D. Douglas, Jr.

    2013-01-01

    Significant advancements in computational fluid dynamics (CFD) and their coupling with computational structural dynamics (CSD, or comprehensive codes) for rotorcraft applications have been achieved recently. Despite this, CSD codes with their engineering level of modeling the rotor blade dynamics, the unsteady sectional aerodynamics and the vortical wake are still the workhorse for the majority of applications. This is especially true when a large number of parameter variations is to be performed and their impact on performance, structural loads, vibration and noise is to be judged in an approximate yet reliable and as accurate as possible manner. In this article, the capabilities of such codes are evaluated using the HART II International Workshop database, focusing on a typical descent operating condition which includes strong blade-vortex interactions. A companion article addresses the CFD/CSD coupled approach. Three cases are of interest: the baseline case and two cases with 3/rev higher harmonic blade root pitch control (HHC) with different control phases employed. One setting is for minimum blade-vortex interaction noise radiation and the other one for minimum vibration generation. The challenge is to correctly predict the wake physics-especially for the cases with HHC-and all the dynamics, aerodynamics, modifications of the wake structure and the aero-acoustics coming with it. It is observed that the comprehensive codes used today have a surprisingly good predictive capability when they appropriately account for all of the physics involved. The minimum requirements to obtain these results are outlined.

  18. Impact of coupled heat and moisture transfer effects on buildings energy consuption

    Directory of Open Access Journals (Sweden)

    Ferroukhi Mohammed Yacine

    2017-01-01

    Full Text Available Coupled heat, air, and moisture transfers through building envelope have an important effect on prediction of building energy requirements. Several works were conducted in order to integrate hygrothermal transfers in dynamic buildings simulations codes. However, the incorporation of multidirectional hygrothermal transfer analysis in the envelope into building simulation tools is rarely considered. In this work, coupled heat, air, and moisture (HAM transfer model in multilayer walls was established. Thereafter, the HAM model is coupled dynamically to a building behavior code (BES.The coupling concerns a co-simulation between COMSOL Multiphysics and TRNSYS software. Afterward, the HAM-BES co-simulation accuracy was verified. Then, HAM-BES co-simulation platform was applied to a case study with various types of climates (temperate, hot and humid, cold and humid. Three simulations cases were carried out. The first simulation case consists of the TRNSYS model without HAM transfer model. The second simulation case, 1-D HAM model for the envelope was integrated in TRNSYS code. For the third one, 1-D HAM model for the wall and 2-D HAM model for thermal bridges were coupled to the thermal building model of TRNSYS. Analysis of the results confirms the significant impact of 2-D envelope hygrothermal transfers on the indoor thermal and moisture behavior of building as well as on the energy building assessment. These conclusions are shown for different studied climates.

  19. Two-Point Codes for the Generalised GK curve

    DEFF Research Database (Denmark)

    Barelli, Élise; Beelen, Peter; Datta, Mrinmoy

    2017-01-01

    completely cover and in many cases improve on their results, using different techniques, while also supporting any GGK curve. Our method builds on the order bound for AG codes: to enable this, we study certain Weierstrass semigroups. This allows an efficient algorithm for computing our improved bounds. We......We improve previously known lower bounds for the minimum distance of certain two-point AG codes constructed using a Generalized Giulietti–Korchmaros curve (GGK). Castellanos and Tizziotti recently described such bounds for two-point codes coming from the Giulietti–Korchmaros curve (GK). Our results...

  20. Thermal comfort in residential buildings: Comfort values and scales for building energy simulation

    Energy Technology Data Exchange (ETDEWEB)

    Peeters, Leen; D' haeseleer, William [Division of Applied Mechanics and Energy Conversion, University of Leuven (K.U.Leuven), Celestijnenlaan 300 A, B-3001 Leuven (Belgium); Dear, Richard de [Division of Environmental and Life Sciences, Macquarie University, Sydney (Australia); Hensen, Jan [Faculty of Architecture, Building and Planning, Technische Universiteit Eindhoven, Vertigo 6.18, P.O. Box 513, 5600 MB Eindhoven (Netherlands)

    2009-05-15

    Building Energy Simulation (BES) programmes often use conventional thermal comfort theories to make decisions, whilst recent research in the field of thermal comfort clearly shows that important effects are not incorporated. The conventional theories of thermal comfort were set up based on steady state laboratory experiments. This, however, is not representing the real situation in buildings, especially not when focusing on residential buildings. Therefore, in present analysis, recent reviews and adaptations are considered to extract acceptable temperature ranges and comfort scales. They will be defined in an algorithm, easily implementable in any BES code. The focus is on comfortable temperature levels in the room, more than on the detailed temperature distribution within that room. (author)

  1. Multi-Year Program Plan - Building Regulatory Programs

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-10-01

    This document presents DOE’s multi-year plan for the three components of the Buildings Regulatory Program: Appliance and Equipment Efficiency Standards, ENERGY STAR, and the Building Energy Codes Program. This document summarizes the history of these programs, the mission and goals of the programs, pertinent statutory requirements, and DOE’s 5-year plan for moving forward.

  2. Active Fault Near-Source Zones Within and Bordering the State of California for the 1997 Uniform Building Code

    Science.gov (United States)

    Petersen, M.D.; Toppozada, Tousson R.; Cao, T.; Cramer, C.H.; Reichle, M.S.; Bryant, W.A.

    2000-01-01

    The fault sources in the Project 97 probabilistic seismic hazard maps for the state of California were used to construct maps for defining near-source seismic coefficients, Na and Nv, incorporated in the 1997 Uniform Building Code (ICBO 1997). The near-source factors are based on the distance from a known active fault that is classified as either Type A or Type B. To determine the near-source factor, four pieces of geologic information are required: (1) recognizing a fault and determining whether or not the fault has been active during the Holocene, (2) identifying the location of the fault at or beneath the ground surface, (3) estimating the slip rate of the fault, and (4) estimating the maximum earthquake magnitude for each fault segment. This paper describes the information used to produce the fault classifications and distances.

  3. Advancing Kohlberg through Codes: Using Professional Codes To Reach the Moral Reasoning Objective in Undergraduate Ethics Courses.

    Science.gov (United States)

    Whitehouse, Ginny; Ingram, Michael T.

    The development of moral reasoning as a key course objective in undergraduate communication ethics classes can be accomplished by the critical and deliberate introduction of professional codes of ethics and the internalization of values found in those codes. Notably, "fostering moral reasoning skills" and "surveying current ethical…

  4. Description and application of the AERIN Code at LLNL

    International Nuclear Information System (INIS)

    King, W.C.

    1986-01-01

    The AERIN code was written at the Lawrence Livermore National Laboratory in 1976 to compute the organ burdens and absorbed dose resulting from a chronic or acute inhalation of transuranic isotopes. The code was revised in 1982 to reflect the concepts of ICRP-30. This paper will describe the AERIN code and how it has been used at LLNL to study more than 80 cases of internal deposition and obtain estimates of internal dose. A comparison with the computed values of the committed organ dose is made with ICRP-30 values. The benefits of using the code are described. 3 refs., 3 figs., 6 tabs

  5. Building physics from physical principles to international standards

    CERN Document Server

    Pinterić, Marko

    2017-01-01

    This textbook provides thorough coverage of the most important building physics phenomena: heat transfer, moisture, sound/acoustics, and illumination. Since the book is primarily aimed at engineers, it addresses professional issues with due pragmatism, and by including many practical examples and related ISO standards. Nevertheless, in order to guarantee full comprehension, it also explains the underlying physical principles and relates them to practical aspects in a simple and clear way. This is achieved with the aid of more than 100 figures and consistent cross-referencing of formulas and ideas. In addition, interrelationships between the different building physics phenomena are elucidated in a way that will enable readers to develop performance specifications that inform the design process. The book will primarily appeal to students of civil engineering and architecture, as well as to all practitioners in these areas who wish to broaden their fundamental understanding of topics in building physics.

  6. Study by similarity of wind influence on mass transfers in complex buildings; Etude par similitude de l'influence du vent sur les transferts de masse dans les batiments complexes

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Nicolas

    2011-12-05

    Residential and industrial buildings equipped with a ventilation system are complex facilities, where various heat and mass transfers could occur according to the operating conditions. In order to study these mass transfers, a methodology has been developed so as to carry out reduced-scale experiments for the study of isothermal flows, in steady or transient state. This methodology has been numerically and experimentally validated on simple configurations, and then applied to two standard configurations, representing nuclear facilities. The wind influence on mass transfers inside these configurations, in normal, damaged (stopping ventilation) or accidental (internal overpressure) situations, has been studied in the Jules Verne climatic wind tunnel of the CSTB. The wind effects, coupled or not with an internal overpressure, can lead to a partial or a total loss of the pollutant's containment inside buildings. Moreover, the wind turbulence can bring about instantaneous reversal leakage flow-rates, which cannot be identified in steady state. In addition, the study of transient phenomena has highlighted the low influence of the branch inertia on transient flows, for typical values of real facilities. Finally, tracer tests have been carried out in order to study the pollutant dispersion inside a standard configuration subjected to wind, mechanical ventilation and internal overpressure effects. The reliability of the zonal code SYLVIA, used notably to support safety assessment in nuclear buildings, has been analyzed from these experimental results. The modelling of the physical phenomena experimentally observed has been validated, in steady and transient states. However, limitations have been identified for the study of pollutant dispersion, due to hypothesis used in SYLVIA code, as in all zonal codes (homogenous concentration inside rooms, instantaneous propagation inside branches and rooms). (author)

  7. Flood-resilient waterfront development in New York City: bridging flood insurance, building codes, and flood zoning.

    Science.gov (United States)

    Aerts, Jeroen C J H; Botzen, W J Wouter

    2011-06-01

    Waterfronts are attractive areas for many-often competing-uses in New York City (NYC) and are seen as multifunctional locations for economic, environmental, and social activities on the interface between land and water. The NYC waterfront plays a crucial role as a first line of flood defense and in managing flood risk and protecting the city from future climate change and sea-level rise. The city of New York has embarked on a climate adaptation program (PlaNYC) outlining the policies needed to anticipate the impacts of climate change. As part of this policy, the Department of City Planning has recently prepared Vision 2020: New York City Comprehensive Waterfront Plan for the over 500 miles of NYC waterfront (NYC-DCP, 2011). An integral part of the vision is to improve resilience to climate change and sea-level rise. This study seeks to provide guidance for advancing the goals of NYC Vision 2020 by assessing how flood insurance, flood zoning, and building code policies can contribute to waterfront development that is more resilient to climate change. © 2011 New York Academy of Sciences.

  8. Compliance Verification Paths for Residential and Commercial Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.; Makela, Eric J.; Fannin, Jerica D.; Sullivan, Robin S.

    2011-10-10

    This report looks at different ways to verify energy code compliance and to ensure that the energy efficiency goals of an adopted document are achieved. Conformity assessment is the body of work that ensures compliance, including activities that can ensure residential and commercial buildings satisfy energy codes and standards. This report identifies and discusses conformity-assessment activities and provides guidance for conducting assessments.

  9. Council Adopts New AERA Code of Ethics: Ethics Committee to Emphasize Ethics Education

    Science.gov (United States)

    Herrington, Carolyn D.

    2011-01-01

    At its February 2011 meeting, the AERA Council adopted unanimously a new Code of Ethics. The Code articulates a set of standards for education researchers in education and provides principles and guidance by which they can build ethical practices in professional, scholarly, and scientific activities. The Code reflects the Association's strong…

  10. Internal exposure from building materials exhaling (222)Rn and (220)Rn as compared to external exposure due to their natural radioactivity content.

    Science.gov (United States)

    Ujić, Predrag; Celiković, Igor; Kandić, Aleksandar; Vukanac, Ivana; Durasević, Mirjana; Dragosavac, Dusan; Zunić, Zora S

    2010-01-01

    The main scope of this paper is to point out the importance of introducing radon and thoron exhalation measurements from building materials in the regulating frame. Currently (2009), such a regulation of this kind of exposure is not explicitly included in the Serbian regulating network. To this end, this work reports concentration measurements of (226)Ra, (232)Th and (40)K and radon and thoron exhalation rates from building materials used in Serbia. Following detailed analysis, it was noticed that both internal exposures to radon and/or thoron exhaling from building materials may exceed external exposures to their precursors contained therein.

  11. OSSMETER D3.2 – Report on Source Code Activity Metrics

    NARCIS (Netherlands)

    J.J. Vinju (Jurgen); A. Shahi (Ashim)

    2014-01-01

    htmlabstractThis deliverable is part of WP3: Source Code Quality and Activity Analysis. It provides descriptions and initial prototypes of the tools that are needed for source code activity analysis. It builds upon the Deliverable 3.1 where infra-structure and a domain analysis have been

  12. Life Cycle Cost optimization of a BOLIG+ Zero Energy Building

    Energy Technology Data Exchange (ETDEWEB)

    Marszal, A.J.

    2011-12-15

    Buildings consume approximately 40% of the world's primary energy use. Considering the total energy consumption throughout the whole life cycle of a building, the energy performance and supply is an important issue in the context of climate change, scarcity of energy resources and reduction of global energy consumption. An energy consuming as well as producing building, labelled as the Zero Energy Building (ZEB) concept, is seen as one of the solutions that could change the picture of energy consumption in the building sector, and thus contribute to the reduction of the global energy use. However, before being fully implemented in the national building codes and international standards, the ZEB concept requires a clear understanding and a uniform definition. The ZEB concept is an energy-conservation solution, whose successful adaptation in real life depends significantly on private building owners' approach to it. For this particular target group, the cost is often an obstacle when investing money in environmental or climate friendly products. Therefore, this PhD project took the perspective of a future private ZEB owner to investigate the cost-optimal Net ZEB definition applicable in the Danish context. The review of the various ZEB approaches indicated a general concept of a Zero Energy Building as a building with significantly reduced energy demand that is balanced by an equivalent energy generation from renewable sources. And, with this as a general framework, each ZEB definition should further specify: (1) the connection or the lack of it to the energy infrastructure, (2) the unit of the balance, (3) the period of the balance, (4) the types of energy use included in the balance, (5) the minimum energy performance requirements (6) the renewable energy supply options, and if applicable (7) the requirements of the building-grid interaction. Moreover, the study revealed that the future ZEB definitions applied in Denmark should mostly be focused on grid

  13. Input/output manual of light water reactor fuel performance code FEMAXI-7 and its related codes

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa [Japan Atomic Energy Agency, Nuclear Safety Research Center, Tokai, Ibaraki (Japan); Saitou, Hiroaki [ITOCHU Techno-Solutions Corp., Tokyo (Japan)

    2012-07-15

    A light water reactor fuel analysis code FEMAXI-7 has been developed for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which has been fully disclosed in the code model description published recently as JAEA-Data/Code 2010-035. The present manual, which is the counterpart of this description, gives detailed explanations of operation method of FEMAXI-7 code and its related codes, methods of Input/Output, methods of source code modification, features of subroutine modules, and internal variables in a specific manner in order to facilitate users to perform a fuel analysis with FEMAXI-7. This report includes some descriptions which are modified from the original contents of JAEA-Data/Code 2010-035. A CD-ROM is attached as an appendix. (author)

  14. Input/output manual of light water reactor fuel performance code FEMAXI-7 and its related codes

    International Nuclear Information System (INIS)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa; Saitou, Hiroaki

    2012-07-01

    A light water reactor fuel analysis code FEMAXI-7 has been developed for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which has been fully disclosed in the code model description published recently as JAEA-Data/Code 2010-035. The present manual, which is the counterpart of this description, gives detailed explanations of operation method of FEMAXI-7 code and its related codes, methods of Input/Output, methods of source code modification, features of subroutine modules, and internal variables in a specific manner in order to facilitate users to perform a fuel analysis with FEMAXI-7. This report includes some descriptions which are modified from the original contents of JAEA-Data/Code 2010-035. A CD-ROM is attached as an appendix. (author)

  15. Rapid prototyping in order to improve building performance simulation for detailed design support

    NARCIS (Netherlands)

    Hopfe, C.J.; Hensen, J.L.M.; Stankov, P.

    2006-01-01

    Building performance simulation (BPS) is a powerful tool to support building and system designers in emulating how orientation, building type, HVAC system etc. interacts the overall building performance. Currently BPS is used only for code compliance in the detailed design, neither to make informed

  16. A Plastic Design Method for RC Moment Frame Buildings against Progressive Collapse

    Directory of Open Access Journals (Sweden)

    Hadi Faghihmaleki

    2017-04-01

    Full Text Available In this study, progressive collapse potential of generic 3-, 8- and 12-storey RC moment frame buildings designed based on IBC-2006 code was investigated by performing non-linear static and dynamic analyses. It was observed that the model structures had high potential for progressive collapse when the second floor column was suddenly removed. Then, the size of beams required to satisfy the failure criteria for progressive collapse was obtained by using the virtual work method; i.e., using the equilibrium of the external work done by gravity load due to loss of a column and the internal work done by plastic rotation of beams. According to the nonlinear dynamic analysis results, the model structures designed only for normal load turned out to have strong potential for progressive collapse whereas the structures designed by plastic design concept for progressive collapse satisfied the failure criterion recommended by the GSA code

  17. Administrative database concerns: accuracy of International Classification of Diseases, Ninth Revision coding is poor for preoperative anemia in patients undergoing spinal fusion.

    Science.gov (United States)

    Golinvaux, Nicholas S; Bohl, Daniel D; Basques, Bryce A; Grauer, Jonathan N

    2014-11-15

    Cross-sectional study. To objectively evaluate the ability of International Classification of Diseases, Ninth Revision (ICD-9) codes, which are used as the foundation for administratively coded national databases, to identify preoperative anemia in patients undergoing spinal fusion. National database research in spine surgery continues to rise. However, the validity of studies based on administratively coded data, such as the Nationwide Inpatient Sample, are dependent on the accuracy of ICD-9 coding. Such coding has previously been found to have poor sensitivity to conditions such as obesity and infection. A cross-sectional study was performed at an academic medical center. Hospital-reported anemia ICD-9 codes (those used for administratively coded databases) were directly compared with the chart-documented preoperative hematocrits (true laboratory values). A patient was deemed to have preoperative anemia if the preoperative hematocrit was less than the lower end of the normal range (36.0% for females and 41.0% for males). The study included 260 patients. Of these, 37 patients (14.2%) were anemic; however, only 10 patients (3.8%) received an "anemia" ICD-9 code. Of the 10 patients coded as anemic, 7 were anemic by definition, whereas 3 were not, and thus were miscoded. This equates to an ICD-9 code sensitivity of 0.19, with a specificity of 0.99, and positive and negative predictive values of 0.70 and 0.88, respectively. This study uses preoperative anemia to demonstrate the potential inaccuracies of ICD-9 coding. These results have implications for publications using databases that are compiled from ICD-9 coding data. Furthermore, the findings of the current investigation raise concerns regarding the accuracy of additional comorbidities. Although administrative databases are powerful resources that provide large sample sizes, it is crucial that we further consider the quality of the data source relative to its intended purpose.

  18. Explicit Constructions and Bounds for Batch Codes with Restricted Size of Reconstruction Sets

    OpenAIRE

    Thomas, Eldho K.; Skachek, Vitaly

    2017-01-01

    Linear batch codes and codes for private information retrieval (PIR) with a query size $t$ and a restricted size $r$ of the reconstruction sets are studied. New bounds on the parameters of such codes are derived for small values of $t$ or of $r$ by providing corresponding constructions. By building on the ideas of Cadambe and Mazumdar, a new bound in a recursive form is derived for batch codes and PIR codes.

  19. Organization and management of ATLAS nightly builds

    International Nuclear Information System (INIS)

    Luehring, F; Obreshkov, E; Quarrie, D; Rybkine, G; Undrus, A

    2010-01-01

    The automated multi-platform software nightly build system is a major component in the ATLAS collaborative software organization, validation and code approval schemes. Code developers from ATLAS participating Institutes spread all around the world use about 30 branches of nightly releases for testing new packages, verification of patches to existing software, and migration to new platforms and compilers. The nightly releases lead up to, and are the basis of, stable software releases used for data processing worldwide. The ATLAS nightly builds are managed by the fully automated NICOS framework on the computing farm with 44 powerful multiprocessor nodes. The ATN test tool is embedded within the nightly system and provides results shortly after full compilations complete. Other test frameworks are synchronized with NICOS jobs and run larger scale validation jobs using the nightly releases. NICOS web pages dynamically provide information about the progress and results of the builds. For faster feedback, E-mail notifications about nightly releases problems are automatically distributed to the developers responsible.

  20. Building an ontology of pulmonary diseases with natural language processing tools using textual corpora.

    Science.gov (United States)

    Baneyx, Audrey; Charlet, Jean; Jaulent, Marie-Christine

    2007-01-01

    Pathologies and acts are classified in thesauri to help physicians to code their activity. In practice, the use of thesauri is not sufficient to reduce variability in coding and thesauri are not suitable for computer processing. We think the automation of the coding task requires a conceptual modeling of medical items: an ontology. Our task is to help lung specialists code acts and diagnoses with software that represents medical knowledge of this concerned specialty by an ontology. The objective of the reported work was to build an ontology of pulmonary diseases dedicated to the coding process. To carry out this objective, we develop a precise methodological process for the knowledge engineer in order to build various types of medical ontologies. This process is based on the need to express precisely in natural language the meaning of each concept using differential semantics principles. A differential ontology is a hierarchy of concepts and relationships organized according to their similarities and differences. Our main research hypothesis is to apply natural language processing tools to corpora to develop the resources needed to build the ontology. We consider two corpora, one composed of patient discharge summaries and the other being a teaching book. We propose to combine two approaches to enrich the ontology building: (i) a method which consists of building terminological resources through distributional analysis and (ii) a method based on the observation of corpus sequences in order to reveal semantic relationships. Our ontology currently includes 1550 concepts and the software implementing the coding process is still under development. Results show that the proposed approach is operational and indicates that the combination of these methods and the comparison of the resulting terminological structures give interesting clues to a knowledge engineer for the building of an ontology.