WorldWideScience

Sample records for inter-zinc finger interactions

  1. From viscous fingers to wormholes - interactions between structures emerging in unstable growth

    Science.gov (United States)

    Budek, Agnieszka; Kwiatkowski, Kamil; Szymczak, Piotr

    2017-04-01

    Dissolution of porous and fractured rock can lead to instabilities, where long finger-like channels or „wormholes" are spontaneously formed, focusing the majority of the flow. Formation of those structures leads to a significant increase in permeability of the system, and is thus important in many engineering applications, e.g. in acidization during oil and gas recovery stimulation. In this communication, we analyse this process using two different numerical models (a network model and a Darcy scale one). We show that wormhole patterns depend strongly on the amount of soluble material in the system, as quantified by the permeability contrast κ between the dissolved and undissolved medium. For small and intermediate values of κ, a large number of relatively thin and strongly interacting channels are formed. The longer channels attract shorter ones, with loops being formed as a result. However, for large values of κ the pattern gets sparse with individual wormholes repelling each other. Interestingly, a similar succession of patterns can be observed in viscous fingering in a rectangular network of channels. In such a system, anisotropy of the network promotes the growth of long and thin fingers which behave similarly to wormholes. The attraction rate between growing fingers depends strongly on the viscosity ratio, I. The latter plays a role similar to that of permeability ratio for dissolution of porous material. To explain this behaviour, we have created a simple analytical model of interacting fingers, allowing us to quantify their mutual interaction as a function of finger lengths, distances between them and - most importantly - relative permeabilities. The theoretical predictions are in a good agreement with simulation data for both dissolution and viscous fingering processes.

  2. Multimodal feedback for finger-based interaction in mobile augmented reality

    NARCIS (Netherlands)

    Hürst, W.O.; Vriens, Kevin

    2016-01-01

    Mobile or handheld augmented reality uses a smartphone's live video stream and enriches it with superimposed graphics. In such scenarios, tracking one's fingers in front of the camera and interpreting these traces as gestures offers interesting perspectives for interaction. Yet, the lack of haptic

  3. Saffman-Taylor streamers: Mutual finger interaction in spark formation

    NARCIS (Netherlands)

    Luque, A.; Brau, F.; Ebert, U.

    2008-01-01

    Bunches of streamers form the early stages of sparks and lightning but theory presently concentrates on single streamers or on coarse approximations of whole breakdown trees. Here a periodic array of interacting streamer discharges in a strong homogeneous electric field is studied in density or

  4. DUF581 is plant specific FCS-like zinc finger involved in protein-protein interaction.

    Directory of Open Access Journals (Sweden)

    Muhammed Jamsheer K

    Full Text Available Zinc fingers are a ubiquitous class of protein domain with considerable variation in structure and function. Zf-FCS is a highly diverged group of C2-C2 zinc finger which is present in animals, prokaryotes and viruses, but not in plants. In this study we identified that a plant specific domain of unknown function, DUF581 is a zf-FCS type zinc finger. Based on HMM-HMM comparison and signature motif similarity we named this domain as FCS-Like Zinc finger (FLZ domain. A genome wide survey identified that FLZ domain containing genes are bryophytic in origin and this gene family is expanded in spermatophytes. Expression analysis of selected FLZ gene family members of A. thaliana identified an overlapping expression pattern suggesting a possible redundancy in their function. Unlike the zf-FCS domain, the FLZ domain found to be highly conserved in sequence and structure. Using a combination of bioinformatic and protein-protein interaction tools, we identified that FLZ domain is involved in protein-protein interaction.

  5. Proteomic analysis of JAZ interacting proteins under methyl jasmonate treatment in finger millet.

    Science.gov (United States)

    Sen, Saswati; Kundu, Sangeeta; Dutta, Samir Kr

    2016-11-01

    Jasmonic acid (JA) signaling pathway in plants is activated against various developmental processes as well as biotic and abiotic stresses. The Jasmonate ZIM-domain (JAZ) protein family, the key regulator of plant JA signaling pathway, also participates in phytohormone crosstalk. This is the first study revealing the in vivo interactions of finger millet (Eleusine coracana (L.) Gaertn.) JAZ protein (EcJAZ) under methyl jasmonate (MJ) treatment. The aim of the study was to explore not only the JA signaling pathway but also the phytohormone signaling crosstalk of finger millet, a highly important future crop. From the MJ-treated finger millet seedlings, the EcJAZ interacting proteins were purified by affinity chromatography with the EcJAZ-matrix. Twenty-one proteins of varying functionalities were successfully identified by MALDI-TOF-TOF Mass spectrometry. Apart from the previously identified JAZ binding proteins, most prominently, EcJAZ was found to interact with transcription factors like NAC, GATA and also with Cold responsive protein (COR), etc. that might have extended the range of functionalities of JAZ proteins. Moreover, to evaluate the interactions of EcJAZ in the JA-co-receptor complex, we generated ten in-silico models containing the EcJAZ degron and the COI1-SKP1 of five monocot cereals viz., rice, wheat, maize, Sorghum and Setaria with JA-Ile or coronatine. Our results indicated that the EcJAZ protein of finger millet could act as the signaling hub for the JA and other phytohormone signaling pathways, in response to a diverse set of stressors and developmental cues to provide survival fitness to the plant. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Dynamic Behavior Analysis of Non-Contacting Hydrodynamic Finger Seal Based on Fluid-Solid-Interaction Method

    Directory of Open Access Journals (Sweden)

    Su Hua

    2018-01-01

    Full Text Available Finger seal is an advanced compliant seal and can be utilized to separate high (HP and low pressure (LP zones in high speed rotating shaft environment. The work to be presented concerns the dynamic behavior of a repetitive section of a two-layer finger seal with high-and padded low-pressure laminates. The dynamic performance of the finger seal are analyzed by the coupled fluid-solid-interaction (FSI simulations. By using the commercial software ANSYS-CFX, the numerical simulation results of interactions between the gas flow and fingers structural deformation are described when the radial periodic excitation from the shaft applies to the finger seal. And the gas film loading capacity, gas film stiffness and leakage varied with time are put forward in different working conditions. Compared with the dynamic performance analysis results based on equivalent dynamic method, the FSI dynamic analysis shows some different characteristics which are more accordance with actual circumstance. Moreover, it is shown that under low pressure differential and high rotation speed the non-contacting finger seal with advance features both in sealing effectiveness and potential unlimited life span can be obtained by rational structure design. But for the non-contacting finger seal with circumferential convergent pad working in high pressure and low rotating speed conditions, it is difficult to improve the sealing performance by the way of changing the structure parameters of finger seal. It is because the high pressure plays a major role on this sealing situation.

  7. Harnessing the Benefits of Bimanual and Multi-finger Input for Supporting Grouping Tasks on Interactive Tabletops

    OpenAIRE

    Geyer, Florian; Höchtl, Anita; Reiterer, Harald

    2012-01-01

    In this paper we describe an experimental study investigating the use of bimanual and multi-finger input for grouping items spatially on a tabletop interface. In a singleuser setup, we compared two typical interaction techniques supporting this task. We studied the grouping and regrouping performance in general and the use of bimanual and multi-finger input in particular. Our results show that the traditional container concept may not be an adequate fit for interactive tabletops. Rather, we d...

  8. Virtual Hand Feedback Reduces Reaction Time in an Interactive Finger Reaching Task.

    Directory of Open Access Journals (Sweden)

    Johannes Brand

    Full Text Available Computer interaction via visually guided hand or finger movements is a ubiquitous part of daily computer usage in work or gaming. Surprisingly, however, little is known about the performance effects of using virtual limb representations versus simpler cursors. In this study 26 healthy right-handed adults performed cued index finger flexion-extension movements towards an on-screen target while wearing a data glove. They received each of four different types of real-time visual feedback: a simple circular cursor, a point light pattern indicating finger joint positions, a cartoon hand and a fully shaded virtual hand. We found that participants initiated the movements faster when receiving feedback in the form of a hand than when receiving circular cursor or point light feedback. This overall difference was robust for three out of four hand versus circle pairwise comparisons. The faster movement initiation for hand feedback was accompanied by a larger movement amplitude and a larger movement error. We suggest that the observed effect may be related to priming of hand information during action perception and execution affecting motor planning and execution. The results may have applications in the use of body representations in virtual reality applications.

  9. Interactional synchrony in chimpanzees: Examination through a finger-tapping experiment.

    Science.gov (United States)

    Yu, Lira; Tomonaga, Masaki

    2015-05-11

    Humans often unconsciously coordinate behaviour with that of others in daily life. This interpersonal coordination, including mimicry and interactional synchrony, has been suggested to play a fundamental role in social interaction. If this coordinative behavior is socially adaptive, it may be shared with other highly social animal species. The current study targeted chimpanzees, which phylogenetically are the closest living relatives of humans and live in complex social groups, and examined whether interactional synchrony would emerge in pairs of chimpanzees when auditory information about a partner's movement was provided. A finger-tapping task was introduced via touch panels to elicit repetitive and rhythmic movement from each chimpanzee. We found that one of four chimpanzees produced significant changes in both tapping tempo and timing of the tapping relative to its partner's tap when auditory sounds were provided. Although the current results may have limitations in generalizing to chimpanzees as a species, we suggest that a finger-tapping task is one potential method to investigate interactional synchrony in chimpanzees under a laboratory setup.

  10. Interaction of Sp1 zinc finger with transport factor in the nuclear localization of transcription factor Sp1

    International Nuclear Information System (INIS)

    Ito, Tatsuo; Kitamura, Haruka; Uwatoko, Chisana; Azumano, Makiko; Itoh, Kohji; Kuwahara, Jun

    2010-01-01

    Research highlights: → Sp1 zinc fingers themselves interact with importin α. → Sp1 zinc finger domains play an essential role as a nuclear localization signal. → Sp1 can be transported into the nucleus in an importin-dependent manner. -- Abstract: Transcription factor Sp1 is localized in the nucleus and regulates the expression of many cellular genes, but the nuclear transport mechanism of Sp1 is not well understood. In this study, we revealed that GST-fused Sp1 protein bound to endogenous importin α in HeLa cells via the Sp1 zinc finger domains, which comprise the DNA binding domain of Sp1. It was found that the Sp1 zinc finger domains directly interacted with a wide range of importin α including the armadillo (arm) repeat domain and the C-terminal acidic domain. Furthermore, it turned out that all three zinc fingers of Sp1 are essential for binding to importin α. Taken together, these results suggest that the Sp1 zinc finger domains play an essential role as a NLS and Sp1 can be transported into the nucleus in an importin-dependent manner even though it possesses no classical NLSs.

  11. A Crowdsensing-Based Real-Time System for Finger Interactions in Intelligent Transport System

    Directory of Open Access Journals (Sweden)

    Chengqun Song

    2017-01-01

    Full Text Available Crowdsensing leverages human intelligence/experience from the general public and social interactions to create participatory sensor networks, where context-aware and semantically complex information is gathered, processed, and shared to collaboratively solve specific problems. This paper proposes a real-time projector-camera finger system based on the crowdsensing, in which user can interact with a computer by bare hand touching on arbitrary surfaces. The interaction process of the system can be completely carried out automatically, and it can be used as an intelligent device in intelligent transport system where the driver can watch and interact with the display information while driving, without causing visual distractions. A single camera is used in the system to recover 3D information of fingertip for hand touch detection. A linear-scanning method is used in the system to determine the touch for increasing the users’ collaboration and operationality. Experiments are performed to show the feasibility of the proposed system. The system is robust to different lighting conditions. The average percentage of correct hand touch detection of the system is 92.0% and the average time of processing one video frame is 30 milliseconds.

  12. Psychomotor Impairment Detection via Finger Interactions with a Computer Keyboard During Natural Typing

    Science.gov (United States)

    Giancardo, L.; Sánchez-Ferro, A.; Butterworth, I.; Mendoza, C. S.; Hooker, J. M.

    2015-04-01

    Modern digital devices and appliances are capable of monitoring the timing of button presses, or finger interactions in general, with a sub-millisecond accuracy. However, the massive amount of high resolution temporal information that these devices could collect is currently being discarded. Multiple studies have shown that the act of pressing a button triggers well defined brain areas which are known to be affected by motor-compromised conditions. In this study, we demonstrate that the daily interaction with a computer keyboard can be employed as means to observe and potentially quantify psychomotor impairment. We induced a psychomotor impairment via a sleep inertia paradigm in 14 healthy subjects, which is detected by our classifier with an Area Under the ROC Curve (AUC) of 0.93/0.91. The detection relies on novel features derived from key-hold times acquired on standard computer keyboards during an uncontrolled typing task. These features correlate with the progression to psychomotor impairment (p < 0.001) regardless of the content and language of the text typed, and perform consistently with different keyboards. The ability to acquire longitudinal measurements of subtle motor changes from a digital device without altering its functionality may allow for early screening and follow-up of motor-compromised neurodegenerative conditions, psychological disorders or intoxication at a negligible cost in the general population.

  13. Trigger finger

    Science.gov (United States)

    ... digit; Trigger finger release; Locked finger; Digital flexor tenosynovitis ... cut or hand Yellow or green drainage from the cut Hand pain or discomfort Fever If your trigger finger returns, call your surgeon. You may need another surgery.

  14. The Effect of Salts in Promoting Specific and Competitive Interactions between Zinc Finger Proteins and Metals

    Science.gov (United States)

    Li, Gongyu; Yuan, Siming; Zheng, Shihui; Chen, Yuting; Zheng, Zhen; Liu, Yangzhong; Huang, Guangming

    2017-12-01

    Specific protein-metal interactions (PMIs) fulfill essential functions in cells and organic bodies, and activation of these functions in vivo are mostly modulated by the complex environmental factors, including pH value, small biomolecules, and salts. Specifically, the role of salts in promoting specific PMIs and their competition among various metals has remained untapped mainly due to the difficulty to distinguish nonspecific PMIs from specific PMIs by classic spectroscopic techniques. Herein, we report Hofmeister salts differentially promote the specific PMIs by combining nanoelectrospray ionization mass spectrometry and spectroscopic techniques (fluorescence measurement and circular dichroism). Furthermore, to explore the influence of salts in competitive binding between metalloproteins and various metals, we designed a series of competitive experiments and applied to a well-defined model system, the competitive binding of zinc (II) and arsenic (III) to holo-promyelocytic leukemia protein (PML). These experiments not only provided new insights at the molecular scale as complementary to previous NMR and spectroscopic results, but also deduced the relative binding ability between zinc finger proteins and metals at the molecular scale, which avoids the mass spectrometric titration-based determination of binding constants that is frequently affected and often degraded by variable solution conditions including salt contents. [Figure not available: see fulltext.

  15. Regulation of hedgehog signaling by Myc-interacting zinc finger protein 1, Miz1.

    Directory of Open Access Journals (Sweden)

    Jiuyi Lu

    Full Text Available Smoothened (Smo mediated Hedgehog (Hh signaling plays an essential role in regulating embryonic development and postnatal tissue homeostasis. Aberrant activation of the Hh pathway contributes to the formation and progression of various cancers. In vertebrates, however, key regulatory mechanisms responsible for transducing signals from Smo to the nucleus remain to be delineated. Here, we report the identification of Myc-interacting Zinc finger protein 1 (Miz1 as a Smo and Gli2 binding protein that positively regulates Hh signaling. Overexpression of Miz1 increases Gli luciferase reporter activity, whereas knockdown of endogenous Miz1 has the opposite effect. Activation of Smo induces translocation of Miz1 to the primary cilia together with Smo and Gli2. Furthermore, Miz1 is localized to the nucleus upon Hh activation in a Smo-dependent manner, and loss of Miz1 prevents the nuclear translocation of Gli2. More importantly, silencing Miz1 expression inhibits cell proliferation in vitro and the growth of Hh-driven medulloblastoma tumors allografted in SCID mice. Taken together, these results identify Miz1 as a novel regulator in the Hh pathway that plays an important role in mediating Smo-dependent oncogenic signaling.

  16. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    Directory of Open Access Journals (Sweden)

    Ge Shuzhi

    2011-03-01

    Full Text Available Abstract Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a varying the internal topology of the finger phalanx and (b varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a little, (b ring, and (c middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to

  17. Multiple Fingers - One Gestalt.

    Science.gov (United States)

    Lezkan, Alexandra; Manuel, Steven G; Colgate, J Edward; Klatzky, Roberta L; Peshkin, Michael A; Drewing, Knut

    2016-01-01

    The Gestalt theory of perception offered principles by which distributed visual sensations are combined into a structured experience ("Gestalt"). We demonstrate conditions whereby haptic sensations at two fingertips are integrated in the perception of a single object. When virtual bumps were presented simultaneously to the right hand's thumb and index finger during lateral arm movements, participants reported perceiving a single bump. A discrimination task measured the bump's perceived location and perceptual reliability (assessed by differential thresholds) for four finger configurations, which varied in their adherence to the Gestalt principles of proximity (small versus large finger separation) and synchrony (virtual spring to link movements of the two fingers versus no spring). According to models of integration, reliability should increase with the degree to which multi-finger cues integrate into a unified percept. Differential thresholds were smaller in the virtual-spring condition (synchrony) than when fingers were unlinked. Additionally, in the condition with reduced synchrony, greater proximity led to lower differential thresholds. Thus, with greater adherence to Gestalt principles, thresholds approached values predicted for optimal integration. We conclude that the Gestalt principles of synchrony and proximity apply to haptic perception of surface properties and that these principles can interact to promote multi-finger integration.

  18. Grasp and index finger reach zone during one-handed smartphone rear interaction: effects of task type, phone width and hand length.

    Science.gov (United States)

    Lee, Songil; Kyung, Gyouhyung; Lee, Jungyong; Moon, Seung Ki; Park, Kyoung Jong

    2016-11-01

    Recently, some smartphones have introduced index finger interaction functions on the rear surface. The current study investigated the effects of task type, phone width, and hand length on grasp, index finger reach zone, discomfort, and muscle activation during such interaction. We considered five interaction tasks (neutral, comfortable, maximum, vertical, and horizontal strokes), two device widths (60 and 90 mm) and three hand lengths. Horizontal (vertical) strokes deviated from the horizontal axis in the range from -10.8° to -13.5° (81.6-88.4°). Maximum strokes appeared to be excessive as these caused 43.8% greater discomfort than did neutral strokes. The 90-mm width also appeared to be excessive as it resulted in 12.3% increased discomfort relative to the 60-mm width. The small-hand group reported 11.9-18.2% higher discomfort ratings, and the percent maximum voluntary exertion of their flexor digitorum superficialis muscle, pertaining to index finger flexion, was also 6.4% higher. These findings should be considered to make smartphone rear interaction more comfortable. Practitioner Summary: Among neutral, comfortable, maximum, horizontal, and vertical index finger strokes on smartphone rear surfaces, maximum vs. neutral strokes caused 43.8% greater discomfort. Horizontal (vertical) strokes deviated from the horizontal (vertical) axis. Discomfort increased by 12.3% with 90-mm- vs. 60-mm-wide devices. Rear interaction regions of five commercialised smartphones should be lowered 20 to 30 mm for more comfortable rear interaction.

  19. Trigger Finger

    Science.gov (United States)

    ... in a bent position. People whose work or hobbies require repetitive gripping actions are at higher risk ... developing trigger finger include: Repeated gripping. Occupations and hobbies that involve repetitive hand use and prolonged gripping ...

  20. HapTip: Displaying Haptic Shear Forces at the Fingertips for Multi-Finger Interaction in Virtual Environments

    Directory of Open Access Journals (Sweden)

    Adrien eGirard

    2016-04-01

    Full Text Available The fingertips are one of the most important and sensitive parts of our body.They are the first stimulated areas of the hand when we interact with our environment.Providing haptic feedback to the fingertips in virtual reality could thus drastically improve perception and interaction with virtual environments.In this paper, we present a modular approach called HapTip to display such haptic sensations at the level of the fingertips.This approach relies on a wearable and compact haptic device able to simulate 2 Degree of Freedom (DoF shear forces on the fingertip with a displacement range of +/- 2 mm. Several modules can be added and used jointly in order to address multi-finger and/or bimanual scenarios in virtual environments.For that purpose, we introduce several haptic rendering techniques to cover different cases of 3D interaction such as touching a rough virtual surface, or feeling the inertia or weight of a virtual object.In order to illustrate the possibilities offered by HapTip, we provide four use cases focused on touching or grasping virtual objects.To validate the efficiency of our approach, we also conducted experiments to assess the tactile perception obtained with HapTip.Our results show that participants can successfully discriminate the directions of the 2 DoF stimulation of our haptic device.We found also that participants could well perceive different weights of virtual objects simulated using two HapTip devices. We believe that HapTip could be used in numerous applications in virtual reality for which 3D manipulation and tactile sensations are often crucial, such as in virtual prototyping or virtual training.

  1. Dual-EEG of joint finger tapping: what can two interacting brains teach us about social interaction?

    DEFF Research Database (Denmark)

    Konvalinka, Ivana

    -frequency analysis revealed a left-motor and right-frontal suppression at 10 Hz during task execution, when carrying the task out interactively in contrast with the uncoupled computer-driven task. We used machine-learning approaches to identify the brain signals driving the interaction. The raw-power at 10 Hz during...... tapping emanating from electrodes of member one and member two were used as features. We combined data from both participants in each pair, and applied logistic regression using feature selection in order to classify the two conditions. The first seven (frontal) electrodes consistently emerged as good...... classifiers, with 85-99% accuracy. There was a tendency for one member’s frontal electrodes to drive the classifier over the other’s, which predicted the leader of the interaction in 8/9 pairs. This study reveals new neural mechanisms underlying two-person interactions. It also shows how analyzing two...

  2. Exploring PHD fingers and H3K4me0 interactions with molecular dynamics simulations and binding free energy calculations: AIRE-PHD1, a comparative study.

    Directory of Open Access Journals (Sweden)

    Dimitrios Spiliotopoulos

    Full Text Available PHD fingers represent one of the largest families of epigenetic readers capable of decoding post-translationally modified or unmodified histone H3 tails. Because of their direct involvement in human pathologies they are increasingly considered as a potential therapeutic target. Several PHD/histone-peptide structures have been determined, however relatively little information is available on their dynamics. Studies aiming to characterize the dynamic and energetic determinants driving histone peptide recognition by epigenetic readers would strongly benefit from computational studies. Herein we focus on the dynamic and energetic characterization of the PHD finger subclass specialized in the recognition of histone H3 peptides unmodified in position K4 (H3K4me0. As a case study we focused on the first PHD finger of autoimmune regulator protein (AIRE-PHD1 in complex with H3K4me0. PCA analysis of the covariance matrix of free AIRE-PHD1 highlights the presence of a "flapping" movement, which is blocked in an open conformation upon binding to H3K4me0. Moreover, binding free energy calculations obtained through Molecular Mechanics/Poisson-Boltzmann Surface Area (MM/PBSA methodology are in good qualitative agreement with experiments and allow dissection of the energetic terms associated with native and alanine mutants of AIRE-PHD1/H3K4me0 complexes. MM/PBSA calculations have also been applied to the energetic analysis of other PHD fingers recognizing H3K4me0. In this case we observe excellent correlation between computed and experimental binding free energies. Overall calculations show that H3K4me0 recognition by PHD fingers relies on compensation of the electrostatic and polar solvation energy terms and is stabilized by non-polar interactions.

  3. Robotic hand and fingers

    Science.gov (United States)

    Salisbury, Curt Michael; Dullea, Kevin J.

    2017-06-06

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  4. The LSD1-Type Zinc Finger Motifs of Pisum sativa LSD1 Are a Novel Nuclear Localization Signal and Interact with Importin Alpha

    OpenAIRE

    He, Shanping; Huang, Kuowei; Zhang, Xu; Yu, Xiangchun; Huang, Ping; An, Chengcai

    2011-01-01

    BACKGROUND: Genetic studies of the Arabidopsis mutant lsd1 highlight the important role of LSD1 in the negative regulation of plant programmed cell death (PCD). Arabidopsis thaliana LSD1 (AtLSD1) contains three LSD1-type zinc finger motifs, which are involved in the protein-protein interaction. METHODOLOGY/PRINCIPAL FINDINGS: To further understand the function of LSD1, we have analyzed cellular localization and functional localization domains of Pisum sativa LSD1 (PsLSD1), which is a homolog ...

  5. Finger Forces in Clarinet Playing

    Directory of Open Access Journals (Sweden)

    Alex Hofmann

    2016-08-01

    Full Text Available Clarinettists close and open multiple tone holes to alter the pitch of the tones. Their fingering technique must be fast, precise, and coordinated with the tongue articulation. In this empirical study, finger force profiles and tongue techniques of clarinet students (N = 17 and professional clarinettists (N = 6 were investigated under controlled performance conditions. First, in an expressive-performance task, eight selected excerpts from the first Weber Concerto were performed. These excerpts were chosen to fit in a 2 x 2 x 2 design (register: low--high; tempo: slow--fast, dynamics: soft--loud. There was an additional condition controlled by the experimenter, which determined the expression levels (low--high of the performers. Second, a technical-exercise task, an isochronous 23-tone melody was designed that required different effectors to produce the sequence (finger-only, tongue-only, combined tongue-finger actions. The melody was performed in three tempo conditions (slow, medium, fast in a synchronization-continuation paradigm. Participants played on a sensor-equipped Viennese clarinet, which tracked finger forces and reed oscillations simultaneously. From the data, average finger force (Fmean and peak force (Fmax were calculated. The overall finger forces were low (Fmean = 1.17 N, Fmax = 3.05 N compared to those on other musical instruments (e.g. guitar. Participants applied the largest finger forces during the high expression level performance conditions (Fmean = 1.21 N.For the technical exercise task, timing and articulation information were extracted from the reed signal. Here, the timing precision of the fingers deteriorated the timing precision of the tongue for combined tongue-finger actions, especially for faster tempi. Although individual finger force profiles were overlapping, the group of professional players applied less finger force overall (Fmean = 0.54 N. Such sensor instruments provide useful insights into player

  6. Number to finger mapping is topological.

    NARCIS (Netherlands)

    Plaisier, M.A.; Smeets, J.B.J.

    2011-01-01

    It has been shown that humans associate fingers with numbers because finger counting strategies interact with numerical judgements. At the same time, there is evidence that there is a relation between number magnitude and space as small to large numbers seem to be represented from left to right. In

  7. Fingers that change color

    Science.gov (United States)

    ... gov/ency/article/003249.htm Fingers that change color To use the sharing features on this page, please enable JavaScript. Fingers or toes may change color when they are exposed to cold temperatures or ...

  8. A cancer-associated RING finger protein, RNF43, is a ubiquitin ligase that interacts with a nuclear protein, HAP95

    International Nuclear Information System (INIS)

    Sugiura, Takeyuki; Yamaguchi, Aya; Miyamoto, Kentaro

    2008-01-01

    RNF43 is a recently discovered RING finger protein that is implicated in colon cancer pathogenesis. This protein possesses growth-promoting activity but its mechanism remains unknown. In this study, to gain insight into the biological action of RNF43 we characterized it biochemically and intracellularly. A combination of indirect immunofluorescence analysis and biochemical fractionation experiments suggests that RNF43 resides in the endoplasmic reticulum (ER) as well as in the nuclear envelope. Sucrose density gradient fractionation demonstrates that RNF43 co-exists with emerin, a representative inner nuclear membrane protein in the nuclear subcompartment. The cell-free system with pure components reveals that recombinant RNF43 fused with maltose-binding protein has autoubiquitylation activity. By the yeast two-hybrid screening we identified HAP95, a chromatin-associated protein interfacing the nuclear envelope, as an RNF43-interacting protein and substantiated this interaction in intact cells by the co-immunoprecipitation experiments. HAP95 is ubiquitylated and subjected to a proteasome-dependent degradation pathway, however, the experiments in which 293 cells expressing both RNF43 and HAP95 were treated with a proteasome inhibitor, MG132, show that HAP95 is unlikely to serve as a substrate of RNF43 ubiquitin ligase. These results infer that RNF43 is a resident protein of the ER and, at least partially, the nuclear membrane, with ubiquitin ligase activity and may be involved in cell growth control potentially through the interaction with HAP95

  9. Differing Dynamics of Intrapersonal and Interpersonal Coordination: Two-finger and Four-Finger Tapping Experiments.

    Directory of Open Access Journals (Sweden)

    Kentaro Kodama

    Full Text Available Finger-tapping experiments were conducted to examine whether the dynamics of intrapersonal and interpersonal coordination systems can be described equally by the Haken-Kelso-Bunz model, which describes inter-limb coordination dynamics. This article reports the results of finger-tapping experiments conducted in both systems. Two within-subject factors were investigated: the phase mode and the number of fingers. In the intrapersonal experiment (Experiment 1, the participants were asked to tap, paced by a gradually hastening auditory metronome, looking at their fingers moving, using the index finger in the two finger condition, or the index and middle finger in the four-finger condition. In the interpersonal experiment (Experiment 2, pairs of participants performed the task while each participant used the outside hand, tapping with the index finger in the two finger condition, or the index and middle finger in the four-finger condition. Some results did not agree with the HKB model predictions. First, from Experiment 1, no significant difference was observed in the movement stability between the in-phase and anti-phase modes in the two finger condition. Second, from Experiment 2, no significant difference was found in the movement stability between the in-phase and anti-phase mode in the four-finger condition. From these findings, different coordination dynamics were inferred between intrapersonal and interpersonal coordination systems against prediction from the previous studies. Results were discussed according to differences between intrapersonal and interpersonal coordination systems in the availability of perceptual information and the complexity in the interaction between limbs derived from a nested structure.

  10. GhZFP1, a novel CCCH-type zinc finger protein from cotton, enhances salt stress tolerance and fungal disease resistance in transgenic tobacco by interacting with GZIRD21A and GZIPR5.

    Science.gov (United States)

    Guo, Ying-Hui; Yu, Yue-Ping; Wang, Dong; Wu, Chang-Ai; Yang, Guo-Dong; Huang, Jin-Guang; Zheng, Cheng-Chao

    2009-01-01

    * Zinc finger proteins are a superfamily involved in many aspects of plant growth and development. However, CCCH-type zinc finger proteins involved in plant stress tolerance are poorly understood. * A cDNA clone designated Gossypium hirsutum zinc finger protein 1 (GhZFP1), which encodes a novel CCCH-type zinc finger protein, was isolated from a salt-induced cotton (G. hirsutum) cDNA library using differential hybridization screening and further studied in transgenic tobacco Nicotiana tabacum cv. NC89. Using yeast two-hybrid screening (Y2H), proteins GZIRD21A (GhZFP1 interacting and responsive to dehydration protein 21A) and GZIPR5 (GhZFP1 interacting and pathogenesis-related protein 5), which interacted with GhZFP1, were isolated. * GhZFP1 contains two typical zinc finger motifs (Cx8Cx5Cx3H and Cx5Cx4Cx3H), a putative nuclear export sequence (NES) and a potential nuclear localization signal (NLS). Transient expression analysis using a GhZFP1::GFP fusion gene in onion epidermal cells indicated a nuclear localization for GhZFP1. RNA blot analysis showed that the GhZFP1 transcript was induced by salt (NaCl), drought and salicylic acid (SA). The regions in GhZFP1 that interact with GZIRD21A and GZIPR5 were identified using truncation mutations. * Overexpression of GhZFP1 in transgenic tobacco enhanced tolerance to salt stress and resistance to Rhizoctonia solani. Therefore, it appears that GhZFP1 might be involved as an important regulator in plant responses to abiotic and biotic stresses.

  11. Isolation of three B-box zinc finger proteins that interact with STF1 and COP1 defines a HY5/COP1 interaction network involved in light control of development in soybean

    International Nuclear Information System (INIS)

    Shin, Su Young; Kim, Seong Hee; Kim, Hye Jin; Jeon, Su Jeong; Sim, Soon Ae; Ryu, Gyeong Ryul; Yoo, Cheol Min; Cheong, Yong Hwa; Hong, Jong Chan

    2016-01-01

    LONG HYPOCOTYL5 (HY5) and STF1 (Soybean TGACG-motif binding Factor 1) are two related bZIP transcription factors that play a positive role in photomorphogenesis and hormonal signaling. In this study, we compared full length STF1 and truncated STF1 overexpression lines and found that the C-terminal 133 amino acids (194–306) possess all the HY5-like function in Arabidopsis. The STF1-DC1 mutant (1–306), with a 20 amino acid deletion at the carboxy terminus, failed to complement the hy5 mutant phenotype, which suggests an intact C-terminus is required for STF1 function. To understand the role of the C-terminal domain in photomorphogenesis we used a yeast two-hybrid screen to isolate proteins that bind to the STF1 C-terminus. We isolated three soybean cDNAs encoding the zinc-finger proteins GmSTO, GmSTH, and GmSTH2, which interact with STF1. These proteins belong to a family of B-box zinc finger proteins that include Arabidopsis SALT TOLERANCE (STO) and STO HOMOLOG (STH) and STH2, which play a role in light-dependent development and gene expression. The C-terminal 63 amino acids of STF1, containing a leucine zipper and the two N-terminal B-boxes, contains the domain involved in interactions between STF1 and GmSTO. In addition, we identified an interaction between soybean COP1 (GmCOP1) and GmSTO and GmSTH, as well as STF1, which strongly suggests the presence of a similar regulatory circuit for light signaling in soybean as in Arabidopsis. This study shows that photomorphogenic control requires complex molecular interactions among several different classes of transcription factors such as bZIP, B-box factors, and COP1, a ubiquitin ligase. - Highlights: • STF1 interact with GmSTO, GmSTH and GmSTH2. • The bZIP transcription factor STF1 requires an intact C-terminal domain for STF1 function. • STF1 and GmSTO are nuclear proteins.

  12. Multi-finger haptic interaction

    CERN Document Server

    Galiana, Ignacio

    2013-01-01

    The H-1B visa is the gateway for the world's best and brightest to live and work in the United States as IT professionals, engineers, scientists, professors, doctors, nurses, and researchers. How to Secure Your H?1B Visa guides employees and employers alike through the maze of H-1B laws, policies, and procedures. This road map lays out the whole H-1B process from petition to visa to status maintenance to visa extension and, ultimately, to permanent residence in the US for you and your family. It shows you step by step exactly how the H-1B process divides up between the employer and employee. I

  13. the strategy of finger use in children's addition Relationship with short-term memory, finger dexterity, and addition skills

    OpenAIRE

    Asakawa, Atsushi; Sugimura, Shinichiro

    2009-01-01

    Previous research has shown that the children's use of the fingers in additon changes with age. In this study, a part of data on the strategy of finger use by Asakawa and Sugimura (2009) was reanalyzed to clarify the relationship between, short-term memory, finger dexterity and addition skills. A two-way ANOVA showed a significant interaction between memory span and finger use. Examination of simple main effect indicated that significant effect of memory span at the group of the children who ...

  14. Multi-fingered robotic hand

    Science.gov (United States)

    Ruoff, Carl F. (Inventor); Salisbury, Kenneth, Jr. (Inventor)

    1990-01-01

    A robotic hand is presented having a plurality of fingers, each having a plurality of joints pivotally connected one to the other. Actuators are connected at one end to an actuating and control mechanism mounted remotely from the hand and at the other end to the joints of the fingers for manipulating the fingers and passing externally of the robot manipulating arm in between the hand and the actuating and control mechanism. The fingers include pulleys to route the actuators within the fingers. Cable tension sensing structure mounted on a portion of the hand are disclosed, as is covering of the tip of each finger with a resilient and pliable friction enhancing surface.

  15. Mixing methods, tasting fingers

    DEFF Research Database (Denmark)

    Mann, Anna; Mol, Annemarie; Satalkar, Priya

    2011-01-01

    This article reports on an ethnographic experiment. Four finger eating experts and three novices sat down for a hot meal and ate with their hands. Drawing on the technique of playing with the familiar and the strange, our aim was not to explain our responses, but to articulate them. As we seek...... words to do so, we are compelled to stretch the verb "to taste." Tasting, or so our ethnographic experiment suggests, need not be understood as an activity confined to the tongue. Instead, if given a chance, it may viscously spread out to the fingers and come to include appreciative reactions otherwise...

  16. A Finger Exoskeleton Robot for Finger Movement Rehabilitation

    Directory of Open Access Journals (Sweden)

    Tzu-Heng Hsu

    2017-07-01

    Full Text Available In this study, a finger exoskeleton robot has been designed and presented. The prototype device was designed to be worn on the dorsal side of the hand to assist in the movement and rehabilitation of the fingers. The finger exoskeleton is 3D-printed to be low-cost and has a transmission mechanism consisting of rigid serial links which is actuated by a stepper motor. The actuation of the robotic finger is by a sliding motion and mimics the movement of the human finger. To make it possible for the patient to use the rehabilitation device anywhere and anytime, an Arduino™ control board and a speech recognition board were used to allow voice control. As the robotic finger follows the patients voice commands the actual motion is analyzed by Tracker image analysis software. The finger exoskeleton is designed to flex and extend the fingers, and has a rotation range of motion (ROM of 44.2°.

  17. Contamination by human fingers. The Midas touch

    International Nuclear Information System (INIS)

    Gwozdz, R.; Grass, F.

    2004-01-01

    Anthropogenic activity is one of the causes of contamination in the human environment: contamination of air, water, top soils, plants and food products has complex effects on human health problems. Wear and abrasion of various surfaces are constant processes in daily life, and commonly include interaction between human fingers and surfaces of every conceivable material. New methods for investigation of trace transfer processes by human fingers are described. Results of transfer for commonly used metals such as gold, silver, zinc, cadmium, tin, cobalt, nickel, chromium and iron are presented. Relationship between transfer of metals by touch and the general problem of purity in analytical activities is briefly discussed. (author)

  18. Mixing methods, tasting fingers

    DEFF Research Database (Denmark)

    Mann, Anna; Mol, Annemarie; Satalkar, Priya

    2011-01-01

    This article reports on an ethnographic experiment. Four finger eating experts and three novices sat down for a hot meal and ate with their hands. Drawing on the technique of playing with the familiar and the strange, our aim was not to explain our responses, but to articulate them. As we seek wo...

  19. Trigger Finger (Stenosing Tenosynovitis)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Trigger Finger Email to a friend * required fields ...

  20. Saffman-Taylor fingers with kinetic undercooling

    KAUST Repository

    Gardiner, Bennett P. J.

    2015-02-23

    © 2015 American Physical Society. The mathematical model of a steadily propagating Saffman-Taylor finger in a Hele-Shaw channel has applications to two-dimensional interacting streamer discharges which are aligned in a periodic array. In the streamer context, the relevant regularization on the interface is not provided by surface tension but instead has been postulated to involve a mechanism equivalent to kinetic undercooling, which acts to penalize high velocities and prevent blow-up of the unregularized solution. Previous asymptotic results for the Hele-Shaw finger problem with kinetic undercooling suggest that for a given value of the kinetic undercooling parameter, there is a discrete set of possible finger shapes, each analytic at the nose and occupying a different fraction of the channel width. In the limit in which the kinetic undercooling parameter vanishes, the fraction for each family approaches 1/2, suggesting that this "selection" of 1/2 by kinetic undercooling is qualitatively similar to the well-known analog with surface tension. We treat the numerical problem of computing these Saffman-Taylor fingers with kinetic undercooling, which turns out to be more subtle than the analog with surface tension, since kinetic undercooling permits finger shapes which are corner-free but not analytic. We provide numerical evidence for the selection mechanism by setting up a problem with both kinetic undercooling and surface tension and numerically taking the limit that the surface tension vanishes.

  1. Saffman-Taylor fingers with kinetic undercooling

    KAUST Repository

    Gardiner, Bennett P. J.; McCue, Scott W.; Dallaston, Michael C.; Moroney, Timothy J.

    2015-01-01

    © 2015 American Physical Society. The mathematical model of a steadily propagating Saffman-Taylor finger in a Hele-Shaw channel has applications to two-dimensional interacting streamer discharges which are aligned in a periodic array. In the streamer context, the relevant regularization on the interface is not provided by surface tension but instead has been postulated to involve a mechanism equivalent to kinetic undercooling, which acts to penalize high velocities and prevent blow-up of the unregularized solution. Previous asymptotic results for the Hele-Shaw finger problem with kinetic undercooling suggest that for a given value of the kinetic undercooling parameter, there is a discrete set of possible finger shapes, each analytic at the nose and occupying a different fraction of the channel width. In the limit in which the kinetic undercooling parameter vanishes, the fraction for each family approaches 1/2, suggesting that this "selection" of 1/2 by kinetic undercooling is qualitatively similar to the well-known analog with surface tension. We treat the numerical problem of computing these Saffman-Taylor fingers with kinetic undercooling, which turns out to be more subtle than the analog with surface tension, since kinetic undercooling permits finger shapes which are corner-free but not analytic. We provide numerical evidence for the selection mechanism by setting up a problem with both kinetic undercooling and surface tension and numerically taking the limit that the surface tension vanishes.

  2. Finger impedance evaluation by means of hand exoskeleton.

    Science.gov (United States)

    Fiorilla, Angelo Emanuele; Nori, Francesco; Masia, Lorenzo; Sandini, Giulio

    2011-12-01

    Modulation of arm mechanical impedance is a fundamental aspect for interaction with the external environment and its regulation is essential for stability preservation during manipulation. Even though past research on human arm movements has suggested that models of human finger impedance would benefit the study of neural control mechanisms and the design of novel hand prostheses, relatively few studies have focused on finger and hand impedance. This article touches on the two main aspects of this research topic: first it introduces a mechanical refinement of a device that can be used to effectively measure finger impedance during manipulation tasks; then, it describes a pilot study aimed at identifying the inertia of the finger and the viscous and elastic properties of finger muscles. The proposed wearable exoskeleton, which has been designed to measure finger posture and impedance modulation while leaving the palm free, is capable of applying fast displacements while monitoring the interaction forces between the human finger and the robotic links. Moreover, due to the relatively small inertia of the fingers, it allows us to meet some stringent specifications, performing relatively large displacements (~45°) before the stretch reflex intervenes (~25 ms). The results of measurements on five subjects show that inertia, damping, and stiffness can be effectively identified and that the parameters obtained are comparable with values from previous studies.

  3. Number magnitude to finger mapping is disembodied and topological.

    Science.gov (United States)

    Plaisier, Myrthe A; Smeets, Jeroen B J

    2011-03-01

    It has been shown that humans associate fingers with numbers because finger counting strategies interact with numerical judgements. At the same time, there is evidence that there is a relation between number magnitude and space as small to large numbers seem to be represented from left to right. In the present study, we investigated whether number magnitude to finger mapping is embodied (related to the order of fingers on the hand) or disembodied (spatial). We let healthy human volunteers name random numbers between 1 and 30, while simultaneously tapping a random finger. Either the hands were placed directly next to each other, 30 cm apart, or the hands were crossed such that the left hand was on the right side of the body mid-line. The results show that naming a smaller number than the previous one was associated with tapping a finger to the left of the previously tapped finger. This shows that there is a spatial (disembodied) mapping between number magnitude and fingers. Furthermore, we show that this mapping is topological rather than metrically scaled.

  4. Robotic Finger Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bridgwater, Lyndon (Inventor); Diftler, Myron A. (Inventor); Linn, Douglas Martin (Inventor); Platt, Robert J., Jr. (Inventor); Hargrave, Brian (Inventor); Askew, Scott R. (Inventor); Valvo, Michael C. (Inventor)

    2014-01-01

    A robotic hand includes a finger with first, second, and third phalanges. A first joint rotatably connects the first phalange to a base structure. A second joint rotatably connects the first phalange to the second phalange. A third joint rotatably connects the third phalange to the second phalange. The second joint and the third joint are kinematically linked such that the position of the third phalange with respect to the second phalange is determined by the position of the second phalange with respect to the first phalange.

  5. Hidradenocarcinoma of the finger.

    Science.gov (United States)

    Nazerali, Rahim S; Tan, Cynthia; Fung, Maxwell A; Chen, Steven L; Wong, Michael S

    2013-04-01

    Hidradenocarcinoma is a rare adnexal neoplasm representing the malignant counterpart of hidradenoma derived from eccrine sweat glands. Misdiagnosis of this disease is common due to the wide variety of histological patterns and rarity of this malignancy. We report an 87-year-old man presenting with a rare case of biopsy-proven hidradenocarcinoma of the finger. There is no standard care of treatment of hidradenocarcinoma, especially of those tumors in rare locations such as the fingers, given its rarity, variable tumor behavior and histology. Although limited treatment strategies exist, detailed data including TNM, location, histologic type and grade, and patient age should be gathered for optimal treatment strategy. The literature supports a 3-fold approach to these malignancies involving margin-free resection, sentinel lymph node biopsy to evaluate possible metastasis, and long-term follow-up given high risk of recurrence. Our treatment strategy involved a 4-fold, multidisciplinary approach involving reconstruction to optimize tumor-free remission and hand function.

  6. Differences in finger localisation performance of patients with finger agnosia.

    Science.gov (United States)

    Anema, Helen A; Kessels, Roy P C; de Haan, Edward H F; Kappelle, L Jaap; Leijten, Frans S; van Zandvoort, Martine J E; Dijkerman, H Chris

    2008-09-17

    Several neuropsychological studies have suggested parallel processing of somatosensory input when localising a tactile stimulus on one's own by pointing towards it (body schema) and when localising this touched location by pointing to it on a map of a hand (body image). Usually these reports describe patients with impaired detection, but intact sensorimotor localisation. This study examined three patients with a lesion of the angular gyrus with intact somatosensory processing, but with selectively disturbed finger identification (finger agnosia). These patients performed normally when pointing towards the touched finger on their own hand but failed to indicate this finger on a drawing of a hand or to name it. Similar defects in the perception of other body parts were not observed. The findings provide converging evidence for the dissociation between body image and body schema and, more importantly, reveal for the first time that this distinction is also present in higher-order cognitive processes selectively for the fingers.

  7. Primary syphilis of the fingers

    OpenAIRE

    Starzycki, Z

    1983-01-01

    Six patients were seen with primary syphilitic chancres on their fingers between 1965 and 1980. Of these, two had bipolar chancres on their fingers and genitals resulting from sexual foreplay. Because syphilis is rarely suspected in such cases diagnostic errors are common.

  8. Emotional Communication in Finger Braille

    Directory of Open Access Journals (Sweden)

    Yasuhiro Matsuda

    2010-01-01

    Full Text Available We describe analyses of the features of emotions (neutral, joy, sadness, and anger expressed by Finger Braille interpreters and subsequently examine the effectiveness of emotional expression and emotional communication between people unskilled in Finger Braille. The goal is to develop a Finger Braille system to teach emotional expression and a system to recognize emotion. The results indicate the following features of emotional expression by interpreters. The durations of the code of joy were significantly shorter than the durations of the other emotions, the durations of the code of sadness were significantly longer, and the finger loads of anger were significantly larger. The features of emotional expression by unskilled subjects were very similar to those of the interpreters, and the coincidence ratio of emotional communication was 75.1%. Therefore, it was confirmed that people unskilled in Finger Braille can express and communicate emotions using this communication medium.

  9. Surgery for trigger finger.

    Science.gov (United States)

    Fiorini, Haroldo Junior; Tamaoki, Marcel Jun; Lenza, Mário; Gomes Dos Santos, Joao Baptista; Faloppa, Flávio; Belloti, Joao Carlos

    2018-02-20

    Trigger finger is a common clinical disorder, characterised by pain and catching as the patient flexes and extends digits because of disproportion between the diameter of flexor tendons and the A1 pulley. The treatment approach may include non-surgical or surgical treatments. Currently there is no consensus about the best surgical treatment approach (open, percutaneous or endoscopic approaches). To evaluate the effectiveness and safety of different methods of surgical treatment for trigger finger (open, percutaneous or endoscopic approaches) in adults at any stage of the disease. We searched CENTRAL, MEDLINE, Embase and LILACS up to August 2017. We included randomised or quasi-randomised controlled trials that assessed adults with trigger finger and compared any type of surgical treatment with each other or with any other non-surgical intervention. The major outcomes were the resolution of trigger finger, pain, hand function, participant-reported treatment success or satisfaction, recurrence of triggering, adverse events and neurovascular injury. Two review authors independently selected the trial reports, extracted the data and assessed the risk of bias. Measures of treatment effect for dichotomous outcomes calculated risk ratios (RRs), and mean differences (MDs) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CIs). When possible, the data were pooled into meta-analysis using the random-effects model. GRADE was used to assess the quality of evidence for each outcome. Fourteen trials were included, totalling 1260 participants, with 1361 trigger fingers. The age of participants included in the studies ranged from 16 to 88 years; and the majority of participants were women (approximately 70%). The average duration of symptoms ranged from three to 15 months, and the follow-up after the procedure ranged from eight weeks to 23 months.The studies reported nine types of comparisons: open surgery versus steroid injections (two

  10. Covering the Dorsal Finger Defect with Reverse Cross Finger Flap

    Directory of Open Access Journals (Sweden)

    Kaan Gurbuz

    2014-12-01

    Full Text Available Reconstruction of finger extensor zone defects with or without tendon gaps still remains a challenge for surgeons. Although surgical treatments may differ, and range from the use of local, regional, to free flaps, the outcomes for all cases are not satisfactory. In this case report, we present a case of a 3rd finger extensor side crush injury including a defect of Dd (Digit Dorsal 1, Dd2 and Dd3 defects of extensor zones with tendon gap. Tendon gap was reconstructed using m. palmaris longus tendon graft and the defect was covered with reversed cross-finger flap (random pattern with good cosmetic and excellent functional results.

  11. Viscous fingering with permeability heterogeneity

    International Nuclear Information System (INIS)

    Tan, C.; Homsy, G.M.

    1992-01-01

    Viscous fingering in miscible displacements in the presence of permeability heterogeneities is studied using two-dimensional simulations. The heterogeneities are modeled as stationary random functions of space with finite correlation scale. Both the variance and scale of the heterogeneities are varied over modest ranges. It is found that the fingered zone grows linearly in time in a fashion analogous to that found in homogeneous media by Tan and Homsy [Phys. Fluids 31, 1330 (1988)], indicating a close coupling between viscous fingering on the one hand and flow through preferentially more permeable paths on the other. The growth rate of the mixing zone increases monotonically with the variance of the heterogeneity, as expected, but shows a maximum as the correlation scale is varied. The latter is explained as a ''resonance'' between the natural scale of fingers in homogeneous media and the correlation scale

  12. Prediction of DNA-binding specificity in zinc finger proteins

    Indian Academy of Sciences (India)

    2012-06-25

    Jun 25, 2012 ... Support Vector Machine (SVM) is a state-of-the-art classifica- tion technique. Using canonical binding model, the C2H2 zinc finger protein–DNA interaction interface is modelled by the pairwise amino acid–base interactions. Using a classification framework, known examples of non-binding ZF–DNA pairs.

  13. OsLOL1, a C2C2-type zinc finger protein, interacts with OsbZIP58 to promote seed germination through the modulation of gibberellin biosynthesis in Oryza sativa.

    Science.gov (United States)

    Wu, Jiahe; Zhu, Chuanfeng; Pang, Jinhuan; Zhang, Xiangrong; Yang, Chunlin; Xia, Guixian; Tian, Yingchuan; He, Chaozu

    2014-12-01

    Seed germination is a key developmental process in the plant life cycle that is influenced by various environmental cues and phytohormones through gene expression and a series of metabolism pathways. In the present study, we investigated a C2C2-type finger protein, OsLOL1, which promotes gibberellin (GA) biosynthesis and affects seed germination in Oryza sativa (rice). We used OsLOL1 antisense and sense transgenic lines to explore OsLOL1 functions. Seed germination timing in antisense plants was restored to wild type when exogenous GA3 was applied. The reduced expression of the GA biosynthesis gene OsKO2 and the accumulation of ent-kaurene were observed during germination in antisense plants. Based on yeast two-hybrid and firefly luciferase complementation analyses, OsLOL1 interacted with the basic leucine zipper protein OsbZIP58. The results from electrophoretic mobility shift and dual-luciferase reporter assays showed that OsbZIP58 binds the G-box cis-element of the OsKO2 promoter and activates LUC reporter gene expression, and that interaction between OsLOL1 and OsbZIP58 activates OsKO2 gene expression. In addition, OsLOL1 decreased SOD1 gene expression and accelerated programmed cell death (PCD) in the aleurone layer of rice grains. These findings demonstrate that the interaction between OsLOL1 and OsbZIP58 influences GA biosynthesis through the activation of OsKO2 via OsbZIP58, thereby stimulating aleurone PCD and seed germination. © 2014 The Authors The Plant Journal © 2014 John Wiley & Sons Ltd.

  14. Polytopic dystelephalangy of the fingers

    International Nuclear Information System (INIS)

    Sugiura, Y.

    1989-01-01

    An 11-year old girl with dystelephalangy (Kirner deformity) of the right middle, ring, and little, and the left index through little fingers is reported. To the author's best knowledge, such polytopic affection with dystelephalangy has not yet been reported. The parents, one of the siblings and maternal grandfather showed dystelephalangy of the little finger. So, the patient was considered to be a homozygous state of dystelephalangy gene. (orig.)

  15. Expression of RIZ1 protein (Retinoblastoma-interacting zinc-finger protein 1) in prostate cancer epithelial cells changes with cancer grade progression and is modulated in vitro by DHT and E2.

    Science.gov (United States)

    Rossi, Valentina; Staibano, Stefania; Abbondanza, Ciro; Pasquali, Daniela; De Rosa, Caterina; Mascolo, Massimo; Bellastella, Giuseppe; Visconti, Daniela; De Bellis, Annamaria; Moncharmont, Bruno; De Rosa, Gaetano; Puca, Giovanni Alfredo; Bellastella, Antonio; Sinisi, Antonio Agostino

    2009-12-01

    The nuclear protein methyl-transferase Retinoblastoma-interacting zinc-finger protein 1 (RIZ1) is considered to be a downstream effector of estrogen action in target tissues. Silencing of RIZ1 expression is common in many tumors. We analyzed RIZ1 expression in normal and malignant prostate tissue and evaluated whether estradiol (E2) or dihydrotestosterone (DHT) treatment modulated RIZ1 in cultured prostate epithelial cells (PEC). Moreover, we studied the possible involvement of RIZ1 in estrogen action on the EPN prostate cell line, constitutively expressing both estrogen receptor (ER)-alpha and beta. RIZ1 protein, found in the nucleus of normal PECs by immunohistochemistry, was progressively lost in cancer tissues as the Gleason score increased and was only detected in the cytoplasmic compartment. RIZ1 transcript levels, as assayed by semi-quantitative RT-PCR in primary PEC cultures, were significantly reduced in cancer cells (P DHT treatment significantly increased RIZ1 transcript and protein levels (P DHT or E2 treatment in vitro. Furthermore, the E2 effects on ER-expressing prostate cells involve RIZ1, which confirms a possible role for ER-mediated pathways in a non-classic E(2)-target tissue.

  16. Integration of tactile input across fingers in a patient with finger agnosia.

    NARCIS (Netherlands)

    Anema, H.A.; Overvliet, K.E.; Smeets, J.B.J.; Brenner, E.; Dijkerman, H.C.

    2011-01-01

    Finger agnosia has been described as an inability to explicitly individuate between the fingers, which is possibly due to fused neural representations of these fingers. Hence, are patients with finger agnosia unable to keep tactile information perceived over several fingers separate? Here, we tested

  17. C. elegans ring finger protein RNF-113 is involved in interstrand DNA crosslink repair and interacts with a RAD51C homolog.

    Directory of Open Access Journals (Sweden)

    Hyojin Lee

    Full Text Available The Fanconi anemia (FA pathway recognizes interstrand DNA crosslinks (ICLs and contributes to their conversion into double-strand DNA breaks, which can be repaired by homologous recombination. Seven orthologs of the 15 proteins associated with Fanconi anemia are functionally conserved in the model organism C. elegans. Here we report that RNF-113, a ubiquitin ligase, is required for RAD-51 focus formation after inducing ICLs in C. elegans. However, the formation of foci of RPA-1 or FCD-2/FANCD2 in the FA pathway was not affected by depletion of RNF-113. Nevertheless, the RPA-1 foci formed did not disappear with time in the depleted worms, implying serious defects in ICL repair. As a result, RNF-113 depletion increased embryonic lethality after ICL treatment in wild-type worms, but it did not increase the ICL-induced lethality of rfs-1/rad51C mutants. In addition, the persistence of RPA-1 foci was suppressed in doubly-deficient rnf-113;rfs-1 worms, suggesting that there is an epistatic interaction between the two genes. These results lead us to suggest that RNF-113 and RFS-1 interact to promote the displacement of RPA-1 by RAD-51 on single-stranded DNA derived from ICLs.

  18. ZifBASE: a database of zinc finger proteins and associated resources

    Directory of Open Access Journals (Sweden)

    Punetha Ankita

    2009-09-01

    Full Text Available Abstract Background Information on the occurrence of zinc finger protein motifs in genomes is crucial to the developing field of molecular genome engineering. The knowledge of their target DNA-binding sequences is vital to develop chimeric proteins for targeted genome engineering and site-specific gene correction. There is a need to develop a computational resource of zinc finger proteins (ZFP to identify the potential binding sites and its location, which reduce the time of in vivo task, and overcome the difficulties in selecting the specific type of zinc finger protein and the target site in the DNA sequence. Description ZifBASE provides an extensive collection of various natural and engineered ZFP. It uses standard names and a genetic and structural classification scheme to present data retrieved from UniProtKB, GenBank, Protein Data Bank, ModBase, Protein Model Portal and the literature. It also incorporates specialized features of ZFP including finger sequences and positions, number of fingers, physiochemical properties, classes, framework, PubMed citations with links to experimental structures (PDB, if available and modeled structures of natural zinc finger proteins. ZifBASE provides information on zinc finger proteins (both natural and engineered ones, the number of finger units in each of the zinc finger proteins (with multiple fingers, the synergy between the adjacent fingers and their positions. Additionally, it gives the individual finger sequence and their target DNA site to which it binds for better and clear understanding on the interactions of adjacent fingers. The current version of ZifBASE contains 139 entries of which 89 are engineered ZFPs, containing 3-7F totaling to 296 fingers. There are 50 natural zinc finger protein entries ranging from 2-13F, totaling to 307 fingers. It has sequences and structures from literature, Protein Data Bank, ModBase and Protein Model Portal. The interface is cross linked to other public

  19. Ret Finger Protein: An E3 Ubiquitin Ligase Juxtaposed to the XY Body in Meiosis

    Directory of Open Access Journals (Sweden)

    Isabelle Gillot

    2009-01-01

    Full Text Available During prophase I of male meiosis, the sex chromosomes form a compact structure called XY body that associates with the nuclear membrane of pachytene spermatocytes. Ret Finger Protein is a transcriptional repressor, able to interact with both nuclear matrix-associated proteins and double-stranded DNA. We report the precise and unique localization of Ret Finger Protein in pachytene spermatocytes, in which Ret Finger Protein takes place of lamin B1, between the XY body and the inner nuclear membrane. This localization of Ret Finger Protein does not seem to be associated with O-glycosylation or sumoylation. In addition, we demonstrate that Ret Finger Protein contains an E3 ubiquitin ligase activity. These observations lead to an attractive hypothesis in which Ret Finger Protein would be involved in the positioning and the attachment of XY body to the nuclear lamina of pachytene spermatocytes.

  20. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  1. EMG finger movement classification based on ANFIS

    Science.gov (United States)

    Caesarendra, W.; Tjahjowidodo, T.; Nico, Y.; Wahyudati, S.; Nurhasanah, L.

    2018-04-01

    An increase number of people suffering from stroke has impact to the rapid development of finger hand exoskeleton to enable an automatic physical therapy. Prior to the development of finger exoskeleton, a research topic yet important i.e. machine learning of finger gestures classification is conducted. This paper presents a study on EMG signal classification of 5 finger gestures as a preliminary study toward the finger exoskeleton design and development in Indonesia. The EMG signals of 5 finger gestures were acquired using Myo EMG sensor. The EMG signal features were extracted and reduced using PCA. The ANFIS based learning is used to classify reduced features of 5 finger gestures. The result shows that the classification of finger gestures is less than the classification of 7 hand gestures.

  2. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  3. [When doors slam, fingers jam!].

    Science.gov (United States)

    Claudet, I; Toubal, K; Carnet, C; Rekhroukh, H; Zelmat, B; Debuisson, C; Cahuzac, J-P

    2007-08-01

    Epidemiological analysis in a universitary paediatric emergency unit of children admitted after accidental injuries resulting from fingers crushed in a door. Prospective, descriptive cohort study from September 6th, 2004 to July 1st, 2005 included all children admitted for finger injuries crushed in a non-automatic door. included accidents due to automatic doors, toy's or refrigerator doors, families who refused to participate to the study or families who had left the waiting area before medical examination. Collected data were patient and family characteristics, accident characteristics and its management. Three hundred and forty children affected by 427 digital lesions were included. The mean age was 5.5+/-3.8 years (range 4 months - 15.5 years). Male/female ratio was equal to 1.2: 1. Fifty-eight percent of patients belonged to families composed of 3 or more siblings. Ninety-three per cent of families came to hospital within the first 2 hours after the accident (mean delay 99+/-162 min, median range 54 minutes). Location of the accident was: domestic (62%, at home (64%)), at school (17%). Locations within the home were: the bedroom (33%), bathroom and toilets (21%). An adult was present in 75% of cases and responsible for the trauma in 25% of accidents, another child in 44%. The finger or fingers were trapped on the hinge side in 57% of patients. No specific safeguard devices were used by 94% of families. Among victims, 20% had several crushed digits; left and right hand were injured with an equal frequency. The commonest involved digits were: the middle finger (29%), the ring finger (23%). The nail plate was damaged in 60% of digital lesions, associated with a wound (50%), a distal phalanx fracture (P3) (12%). Six children had a partial or complete amputation of P3, 2 children a lesion of the extensor tendon, 1 child had a rupture of the external lateral ligament. Three percent of children required an admission to the paediatric orthopaedic surgery unit. Post

  4. Impact of Finger Type in Fingerprint Authentication

    Science.gov (United States)

    Gafurov, Davrondzhon; Bours, Patrick; Yang, Bian; Busch, Christoph

    Nowadays fingerprint verification system is the most widespread and accepted biometric technology that explores various features of the human fingers for this purpose. In general, every normal person has 10 fingers with different size. Although it is claimed that recognition performance with little fingers can be less accurate compared to other finger types, to our best knowledge, this has not been investigated yet. This paper presents our study on the topic of influence of the finger type into fingerprint recognition performance. For analysis we employ two fingerprint verification software packages (one public and one commercial). We conduct test on GUC100 multi sensor fingerprint database which contains fingerprint images of all 10 fingers from 100 subjects. Our analysis indeed confirms that performance with small fingers is less accurate than performance with the others fingers of the hand. It also appears that best performance is being obtained with thumb or index fingers. For example, performance deterioration from the best finger (i.e. index or thumb) to the worst fingers (i.e. small ones) can be in the range of 184%-1352%.

  5. Optimization for Guitar Fingering on Single Notes

    Science.gov (United States)

    Itoh, Masaru; Hayashida, Takumi

    This paper presents an optimization method for guitar fingering. The fingering is to determine a unique combination of string, fret and finger corresponding to the note. The method aims to generate the best fingering pattern for guitar robots rather than beginners. Furthermore, it can be applied to any musical score on single notes. A fingering action can be decomposed into three motions, that is, a motion of press string, release string and move fretting hand. The cost for moving the hand is estimated on the basis of Manhattan distance which is the sum of distances along fret and string directions. The objective is to minimize the total fingering costs, subject to fret, string and finger constraints. As a sequence of notes on the score forms a line on time series, the optimization for guitar fingering can be resolved into a multistage decision problem. Dynamic programming is exceedingly effective to solve such a problem. A level concept is introduced into rendering states so as to make multiple DP solutions lead a unique one among the DP backward processes. For example, if two fingerings have the same value of cost at different states on a stage, then the low position would be taken precedence over the high position, and the index finger would be over the middle finger.

  6. Integration of tactile input across fingers in a patient with finger agnosia.

    Science.gov (United States)

    Anema, Helen A; Overvliet, Krista E; Smeets, Jeroen B J; Brenner, Eli; Dijkerman, H Chris

    2011-01-01

    Finger agnosia has been described as an inability to explicitly individuate between the fingers, which is possibly due to fused neural representations of these fingers. Hence, are patients with finger agnosia unable to keep tactile information perceived over several fingers separate? Here, we tested a finger agnosic patient (GO) on two tasks that measured the ability to keep tactile information simultaneously perceived by individual fingers separate. In experiment 1 GO performed a haptic search task, in which a target (the absence of a protruded line) needed to be identified among distracters (protruded lines). The lines were presented simultaneously to the fingertips of both hands. Similarly to the controls, her reaction time decreased when her fingers were aligned as compared to when her fingers were stretched and in an unaligned position. This suggests that she can keep tactile input from different fingers separate. In experiment two, GO was required to judge the position of a target tactile stimulus to the index finger, relatively to a reference tactile stimulus to the middle finger, both in fingers uncrossed and crossed position. GO was able to indicate the relative position of the target stimulus as well as healthy controls, which indicates that she was able to keep tactile information perceived by two neighbouring fingers separate. Interestingly, GO performed better as compared to the healthy controls in the finger crossed condition. Together, these results suggest the GO is able to implicitly distinguish between tactile information perceived by multiple fingers. We therefore conclude that finger agnosia is not caused by minor disruptions of low-level somatosensory processing. These findings further underpin the idea of a selective impaired higher order body representation restricted to the fingers as underlying cause of finger agnosia. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Viscous Fingering in Deformable Systems

    Science.gov (United States)

    Guan, Jian Hui; MacMinn, Chris

    2017-11-01

    Viscous fingering is a classical hydrodynamic instability that occurs when an invading fluid is injected into a porous medium or a Hele-Shaw cell that contains a more viscous defending fluid. Recent work has shown that viscous fingering in a Hele-Shaw cell is supressed when the flow cell is deformable. However, the mechanism of suppression relies on a net volumetric expansion of the flow area. Here, we study flow in a novel Hele-Shaw cell consisting of a rigid bottom plate and a flexible top plate that deforms in a way that is volume-conserving. In other words, fluid injection into the flow cell leads to a local expansion of the flow area (outward displacement of the flexible surface) that must be coupled to non-local contraction (inward displacement of the flexible surface). We explore the impact of this volumetric confinement on steady viscous flow and on viscous fingering. We would like to thank EPSRC for the funding for this work.

  8. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  9. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  10. A multiscale approach to simulating the conformational properties of unbound multi-C₂H₂ zinc finger proteins.

    Science.gov (United States)

    Liu, Lei; Wade, Rebecca C; Heermann, Dieter W

    2015-09-01

    The conformational properties of unbound multi-Cys2 His2 (mC2H2) zinc finger proteins, in which zinc finger domains are connected by flexible linkers, are studied by a multiscale approach. Three methods on different length scales are utilized. First, atomic detail molecular dynamics simulations of one zinc finger and its adjacent flexible linker confirmed that the zinc finger is more rigid than the flexible linker. Second, the end-to-end distance distributions of mC2H2 zinc finger proteins are computed using an efficient atomistic pivoting algorithm, which only takes excluded volume interactions into consideration. The end-to-end distance distribution gradually changes its profile, from left-tailed to right-tailed, as the number of zinc fingers increases. This is explained by using a worm-like chain model. For proteins of a few zinc fingers, an effective bending constraint favors an extended conformation. Only for proteins containing more than nine zinc fingers, is a somewhat compacted conformation preferred. Third, a mesoscale model is modified to study both the local and the global conformational properties of multi-C2H2 zinc finger proteins. Simulations of the CCCTC-binding factor (CTCF), an important mC2H2 zinc finger protein for genome spatial organization, are presented. © 2015 Wiley Periodicals, Inc.

  11. In the finger it lingers

    Directory of Open Access Journals (Sweden)

    Irfan Mohamad

    2017-08-01

    Full Text Available A previously healthy 80-year-old woman presented with a history of a thorn prick injury over the distal phalange of her left finger obtained while gardening two months ago. She claimed to have a non-healing cut with a nodular lesion, which progressively increased in size, extending upwards towards the region of her left arm. There was no fever or palpable lymph nodes in the axillary region. She had been prescribed antibiotics from the local hospital but her condition did not improve.

  12. Instrumented Glove Measures Positions Of Fingers

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

  13. Generating and analyzing synthetic finger vein images

    OpenAIRE

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have posed challenges in exploring this technology for large scale applications. This paper details the first such attempt to synthesize finger-vein images and presents analysis of synthesized images fo...

  14. Application of autoradiography in finger print analysis

    International Nuclear Information System (INIS)

    Stverak, B.; Kopejtko, J.; Simek, J.

    1983-01-01

    In order to broaden the possibilities of developing latent finger prints a tracer technique has been developed using sup(110m)Ag and autoradiographic imaging. This method has been tested on glass, paper and certain plastics. On paper it is possible to visualize finger prints even after previous development using Ninhydrin. It is shown that usable finger prints may be obtained also from materials from which they cannot be obtained using classical methods, e.g., polyethylene and simulated leather. (author)

  15. Generating and analyzing synthetic finger vein images

    NARCIS (Netherlands)

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have

  16. Surgical Treatment of Trigger Finger: Open Release

    Directory of Open Access Journals (Sweden)

    Firat Ozan

    2016-01-01

    Full Text Available In this study, open A1 pulley release results were evaluated in patients with a trigger finger diagnosis. 45 patients (29 females, 16 males, mean age 50.7 ± 11.9; range (24-79, 45 trigger fingers were released via open surgical technique. On the 25 of 45 cases were involved in the right hand and 16 of them were at the thumb, 2 at index, 6 at the middle and 1 at ring finger. Similarly, at the left hand, 15 of 20 cases were at the thumb, 1 at the index finger, 2 at middle finger and 2 at ring finger. Average follow-up time was 10.2 ± 2.7 (range, 6-15 months. Comorbidities in patients were; diabetes mellitus at 6 cases (13.3%, hypertension at 11 cases (24.4%, hyperthyroidism at 2 cases (4.4%, dyslipidemia at 2 cases (4.4% and lastly 2 cases had carpal tunnel syndrome operation. The mean time between the onset of symptoms to surgery was 6.9 ± 4.8 (range, 2-24 months. Patient satisfaction was very good in 34 cases (75.4% and good in 11 (24.6% patients. The distance between the pulpa of the operated finger and the palm was normal in every case postoperatively. We have not encountered any postoperative complications. We can recommend that; A1 pulley release via open incision is an effective and reliable method in trigger finger surgery.

  17. Generic Automated Multi-function Finger Design

    Science.gov (United States)

    Honarpardaz, M.; Tarkian, M.; Sirkett, D.; Ölvander, J.; Feng, X.; Elf, J.; Sjögren, R.

    2016-11-01

    Multi-function fingers that are able to handle multiple workpieces are crucial in improvement of a robot workcell. Design automation of multi-function fingers is highly demanded by robot industries to overcome the current iterative, time consuming and complex manual design process. However, the existing approaches for the multi-function finger design automation are unable to entirely meet the robot industries’ need. This paper proposes a generic approach for design automation of multi-function fingers. The proposed approach completely automates the design process and requires no expert skill. In addition, this approach executes the design process much faster than the current manual process. To validate the approach, multi-function fingers are successfully designed for two case studies. Further, the results are discussed and benchmarked with existing approaches.

  18. Electrokinetic Control of Viscous Fingering

    Science.gov (United States)

    Mirzadeh, Mohammad; Bazant, Martin Z.

    2017-10-01

    We present a theory of the interfacial stability of two immiscible electrolytes under the coupled action of pressure gradients and electric fields in a Hele-Shaw cell or porous medium. Mathematically, our theory describes a phenomenon of "vector Laplacian growth," in which the interface moves in response to the gradient of a vector-valued potential function through a generalized mobility tensor. Physically, we extend the classical Saffman-Taylor problem to electrolytes by incorporating electrokinetic (EK) phenomena. A surprising prediction is that viscous fingering can be controlled by varying the injection ratio of electric current to flow rate. Beyond a critical injection ratio, stability depends only upon the relative direction of flow and current, regardless of the viscosity ratio. Possible applications include porous materials processing, electrically enhanced oil recovery, and EK remediation of contaminated soils.

  19. Finger tips detection for two handed gesture recognition

    Science.gov (United States)

    Bhuyan, M. K.; Kar, Mithun Kumar; Neog, Debanga Raj

    2011-10-01

    In this paper, a novel algorithm is proposed for fingertips detection in view of two-handed static hand pose recognition. In our method, finger tips of both hands are detected after detecting hand regions by skin color-based segmentation. At first, the face is removed in the image by using Haar classifier and subsequently, the regions corresponding to the gesturing hands are isolated by a region labeling technique. Next, the key geometric features characterizing gesturing hands are extracted for two hands. Finally, for all possible/allowable finger movements, a probabilistic model is developed for pose recognition. Proposed method can be employed in a variety of applications like sign language recognition and human-robot-interactions etc.

  20. Zinc-finger proteins in health and disease.

    Science.gov (United States)

    Cassandri, Matteo; Smirnov, Artem; Novelli, Flavia; Pitolli, Consuelo; Agostini, Massimiliano; Malewicz, Michal; Melino, Gerry; Raschellà, Giuseppe

    2017-01-01

    Zinc-finger proteins (ZNFs) are one of the most abundant groups of proteins and have a wide range of molecular functions. Given the wide variety of zinc-finger domains, ZNFs are able to interact with DNA, RNA, PAR (poly-ADP-ribose) and other proteins. Thus, ZNFs are involved in the regulation of several cellular processes. In fact, ZNFs are implicated in transcriptional regulation, ubiquitin-mediated protein degradation, signal transduction, actin targeting, DNA repair, cell migration, and numerous other processes. The aim of this review is to provide a comprehensive summary of the current state of knowledge of this class of proteins. Firstly, we describe the actual classification of ZNFs, their structure and functions. Secondly, we focus on the biological role of ZNFs in the development of organisms under normal physiological and pathological conditions.

  1. Magic Ring: A Finger-Worn Device for Multiple Appliances Control Using Static Finger Gestures

    Directory of Open Access Journals (Sweden)

    Tongjun Huang

    2012-05-01

    Full Text Available An ultimate goal for Ubiquitous Computing is to enable people to interact with the surrounding electrical devices using their habitual body gestures as they communicate with each other. The feasibility of such an idea is demonstrated through a wearable gestural device named Magic Ring (MR, which is an original compact wireless sensing mote in a ring shape that can recognize various finger gestures. A scenario of wireless multiple appliances control is selected as a case study to evaluate the usability of such a gestural interface. Experiments comparing the MR and a Remote Controller (RC were performed to evaluate the usability. From the results, only with 10 minutes practice, the proposed paradigm of gestural-based control can achieve a performance of completing about six tasks per minute, which is in the same level of the RC-based method.

  2. Intracellular HIV-1 Gag localization is impaired by mutations in the nucleocapsid zinc fingers

    Directory of Open Access Journals (Sweden)

    Muriaux Delphine

    2007-08-01

    Full Text Available Abstract Background The HIV-1 nucleocapsid protein (NC is formed of two CCHC zinc fingers flanked by highly basic regions. HIV-1 NC plays key roles in virus structure and replication via its nucleic acid binding and chaperoning properties. In fact, NC controls proviral DNA synthesis by reverse transcriptase (RT, gRNA dimerization and packaging, and virion assembly. Results We previously reported a role for the first NC zinc finger in virion structure and replication 1. To investigate the role of both NC zinc fingers in intracellular Gag trafficking, and in virion assembly, we generated series of NC zinc fingers mutations. Results show that all Zinc finger mutations have a negative impact on virion biogenesis and maturation and rendered defective the mutant viruses. The NC zinc finger mutations caused an intracellular accumulation of Gag, which was found either diffuse in the cytoplasm or at the plasma membrane but not associated with endosomal membranes as for wild type Gag. Evidences are also provided showing that the intracellular interactions between NC-mutated Gag and the gRNA were impaired. Conclusion These results show that Gag oligomerization mediated by gRNA-NC interactions is required for correct Gag trafficking, and assembly in HIV-1 producing cells and the release of infectious viruses.

  3. Radiosynoviorthesis in osteoarthritis of finger joints

    International Nuclear Information System (INIS)

    Moedder, G.

    2006-01-01

    This is an overview about osteoarthritis of the finger joints. The scientific publications according to the therapy of this disease by means of radiosynoviorthesis are presented, comparing the results in rheumatoid arthritis. Additionally own experience and results are reported. (orig.)

  4. Two-finger (TF) SPUDT cells.

    Science.gov (United States)

    Martin, Guenter; Biryukov, Sergey V; Schmidt, Hagen; Steiner, Bernd; Wall, Bert

    2011-03-01

    SPUDT cells including two fingers are only known thus far for so-called NSPUDT directions. In that case, usual solid-finger cells are used. The purpose of the present paper is to find SPUDT cell types consisting of two fingers only for pure mode directions. Two-finger (TF) cells for pure mode directions on substrates like 128°YX LiNbO(3) and YZ LiNbO(3) were found by means of an optimization procedure. The forward direction of a TF-cell SPUDT on 128°YX LiNbO(3) was determined experimentally. The properties of the new cells are compared with those of conventional SPUDT cells. The reflectivity of TF cells on 128°YX LiNbO(3) turns out to be two to three times larger than that of distributed acoustic reflection transducer (DART) and Hanma-Hunsinger cells at the same metal layer thickness.

  5. Finger prosthesis: a boon to handicapped.

    Science.gov (United States)

    Gupta, Ridhima; Kumar, Lakshya; Rao, Jitendra; Singh, Kamleshwar

    2013-08-29

    This is a clinical case report of a 52-year-old male patient with four partially missing fingers of the left hand. The article describes the clinical and laboratory procedure of making prosthesis with modern silicone material. A wax pattern was fabricated using the right hand of the patient. A special type of wax was formulated to make the pattern so that it can be easily moulded and carved. Intrinsic and extrinsic staining was also performed to match the adjacent skin colour. The patient was given the finger prosthesis and was asked to use a half glove (sports) to mask the junction between the prosthesis and the normal tissue. It also provides additional retention to the artificial fingers. The patient felt his social acceptance improved after wearing the finger prosthesis.

  6. Index finger somatosensory evoked potentials in blind Braille readers.

    Science.gov (United States)

    Giriyappa, Dayananda; Subrahmanyam, Roopakala Mysore; Rangashetty, Srinivasa; Sharma, Rajeev

    2009-01-01

    Traditionally, vision has been considered the dominant modality in our multi-sensory perception of the surrounding world. Sensory input via non-visual tracts becomes of greater behavioural relevance in totally blind individuals to enable effective interaction with the world around them. These include audition and tactile perceptions, leading to an augmentation in these perceptions when compared with normal sighted individuals. The objective of the present work was to study the index finger somatosensory evoked potentials (SEPs) in totally blind and normal sighted individuals. SEPs were recorded in 15 Braille reading totally blind females and compared with 15 age-matched normal sighted females. Latency and amplitudes of somatosensory evoked potential waveforms (N9, N13, and N20) were measured. Amplitude of N20 SEP (a cortical somatosensory evoked potential) was significantly larger in the totally blind than in normal sighted individuals (p Braille reading right index finger. Totally blind Braille readers have larger N20 amplitude, suggestive of greater somatosensory cortical representation of the Braille reading index finger.

  7. Stainless steel quadralatch finger test report

    International Nuclear Information System (INIS)

    Deichelbohrer, P.R.

    1996-01-01

    The design of the quadralatch on the universal samplers was changed in response to flammable gas operating constraints. Additional redesign of the fingers was included to facilitate manufacturability. The new design was tested to assure satisfactory performance. It was shown that the fingers can hold a sampler in place with an upward force of at least 2200 N (500 pounds) and that the mechanical remote latch unit can release the quadralatch under this condition of maximum upward force

  8. Finger Search in the Implicit Model

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Nielsen, Jesper Asbjørn Sindahl; Truelsen, Jakob

    2012-01-01

    We address the problem of creating a dictionary with the finger search property in the strict implicit model, where no information is stored between operations, except the array of elements. We show that for any implicit dictionary supporting finger searches in q(t) = Ω(logt) time, the time to move...... the finger to another element is Ω(q− 1(logn)), where t is the rank distance between the query element and the finger. We present an optimal implicit static structure matching this lower bound. We furthermore present a near optimal implicit dynamic structure supporting search, change-finger, insert......, and delete in times $\\mathcal{O}(q(t))$, $\\mathcal{O}(q^{-1}(\\log n)\\log n)$, $\\mathcal{O}(\\log n)$, and $\\mathcal{O}(\\log n)$, respectively, for any q(t) = Ω(logt). Finally we show that the search operation must take Ω(logn) time for the special case where the finger is always changed to the element...

  9. Finger replantation: surgical technique and indications.

    Science.gov (United States)

    Barbary, S; Dap, F; Dautel, G

    2013-12-01

    In this article, we discuss the surgical technique of finger replantation in detail, distinguishing particularities of technique in cases of thumb amputation, children fingertip replantation, ring finger avulsion, and very distal replantations. We emphasize the principles of bone shortening, the spare part concept, the special importance of nerve sutures and the use of vein graft in case of avulsion or crushing. However, even if finger replantation is now a routine procedure, a clear distinction should be made between revascularization and functional success. The indications for finger replantation are then detailed in the second part of this paper. The absolute indications for replantation are thumb, multiple fingers, transmetacarpal or hand, and any upper extremity amputation in a child whatever the level. Fingertip amputations distal to the insertion of the Flexor digitorum superficialis (FDS) are also a good indication. Other cases are more controversial because of the poor functional outcome, especially for the index finger, which is often functionally excluded. Copyright © 2013. Published by Elsevier SAS.

  10. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  11. Finger pad friction and its role in grip and touch.

    Science.gov (United States)

    Adams, Michael J; Johnson, Simon A; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-03-06

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick-slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function.

  12. New Finger Biometric Method Using Near Infrared Imaging

    Science.gov (United States)

    Lee, Eui Chul; Jung, Hyunwoo; Kim, Daeyeoul

    2011-01-01

    In this paper, we propose a new finger biometric method. Infrared finger images are first captured, and then feature extraction is performed using a modified Gaussian high-pass filter through binarization, local binary pattern (LBP), and local derivative pattern (LDP) methods. Infrared finger images include the multimodal features of finger veins and finger geometries. Instead of extracting each feature using different methods, the modified Gaussian high-pass filter is fully convolved. Therefore, the extracted binary patterns of finger images include the multimodal features of veins and finger geometries. Experimental results show that the proposed method has an error rate of 0.13%. PMID:22163741

  13. Finger multibiometric cryptosystems: fusion strategy and template security

    Science.gov (United States)

    Peng, Jialiang; Li, Qiong; Abd El-Latif, Ahmed A.; Niu, Xiamu

    2014-03-01

    We address two critical issues in the design of a finger multibiometric system, i.e., fusion strategy and template security. First, three fusion strategies (feature-level, score-level, and decision-level fusions) with the corresponding template protection technique are proposed as the finger multibiometric cryptosystems to protect multiple finger biometric templates of fingerprint, finger vein, finger knuckle print, and finger shape modalities. Second, we theoretically analyze different fusion strategies for finger multibiometric cryptosystems with respect to their impact on security and recognition accuracy. Finally, the performance of finger multibiometric cryptosystems at different fusion levels is investigated on a merged finger multimodal biometric database. The comparative results suggest that the proposed finger multibiometric cryptosystem at feature-level fusion outperforms other approaches in terms of verification performance and template security.

  14. Rehabilitation of single finger amputation with customized silicone prosthesis

    OpenAIRE

    Yadav, Niharika; Chand, Pooran; Jurel, Sunit Kumar

    2016-01-01

    Finger amputations are common in accidents at home, work, and play. Apart from trauma, congenital disease and deformity also leads to finger amputation. This results in loss of function, loss of sensation as well as loss of body image. Finger prosthesis offers psychological support and social acceptance in such cases. This clinical report describes a method to fabricate ring retained silicone finger prosthesis in a patient with partial finger loss.

  15. Finger tapping ability in healthy elderly and young adults.

    Science.gov (United States)

    Aoki, Tomoko; Fukuoka, Yoshiyuki

    2010-03-01

    The maximum isometric force production capacity of the fingers decreases with age. However, little information is available on age-related changes in dynamic motor capacity of individual fingers. The purpose of this study was to compare the dynamic motor function of individual fingers between elderly and young adults using rapid single-finger and double-finger tapping. Fourteen elderly and 14 young adults performed maximum frequency tapping by the index, middle, ring, or little finger (single-finger tapping) and with alternate movements of the index-middle, middle-ring, or ring-little finger-pair (double-finger tapping). The maximum pinch force between the thumb and each finger, tactile sensitivity of each fingertip, and time taken to complete a pegboard test were also measured. Compared with young subjects, the older subjects had significantly slower tapping rates in all fingers and finger-pairs in the tapping tasks. The age-related decline was also observed in the tactile sensitivities of all fingers and in the pegboard test. However, there was no group difference in the pinch force of any finger. The tapping rate of each finger did not correlate with the pinch force or tactile sensitivity for the corresponding finger in the elderly subjects. Maximum rate of finger tapping was lower in the elderly adults compared with the young adults. The decline of finger tapping ability in elderly adults seems to be less affected by their maximum force production capacities of the fingers as well as tactile sensitivities at the tips of the fingers.

  16. Design and preliminary evaluation of the FINGER rehabilitation robot: controlling challenge and quantifying finger individuation during musical computer game play.

    Science.gov (United States)

    Taheri, Hossein; Rowe, Justin B; Gardner, David; Chan, Vicki; Gray, Kyle; Bower, Curtis; Reinkensmeyer, David J; Wolbrecht, Eric T

    2014-02-04

    This paper describes the design and preliminary testing of FINGER (Finger Individuating Grasp Exercise Robot), a device for assisting in finger rehabilitation after neurologic injury. We developed FINGER to assist stroke patients in moving their fingers individually in a naturalistic curling motion while playing a game similar to Guitar Hero. The goal was to make FINGER capable of assisting with motions where precise timing is important. FINGER consists of a pair of stacked single degree-of-freedom 8-bar mechanisms, one for the index and one for the middle finger. Each 8-bar mechanism was designed to control the angle and position of the proximal phalanx and the position of the middle phalanx. Target positions for the mechanism optimization were determined from trajectory data collected from 7 healthy subjects using color-based motion capture. The resulting robotic device was built to accommodate multiple finger sizes and finger-to-finger widths. For initial evaluation, we asked individuals with a stroke (n = 16) and without impairment (n = 4) to play a game similar to Guitar Hero while connected to FINGER. Precision design, low friction bearings, and separate high speed linear actuators allowed FINGER to individually actuate the fingers with a high bandwidth of control (-3 dB at approximately 8 Hz). During the tests, we were able to modulate the subject's success rate at the game by automatically adjusting the controller gains of FINGER. We also used FINGER to measure subjects' effort and finger individuation while playing the game. Test results demonstrate the ability of FINGER to motivate subjects with an engaging game environment that challenges individuated control of the fingers, automatically control assistance levels, and quantify finger individuation after stroke.

  17. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger-arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3-DOF fingers are attached to the end-effector of a 6-DOF arm to configure a multi-finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi-finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini-max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi-finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  18. Quantifying Parkinson's disease finger-tapping severity by extracting and synthesizing finger motion properties.

    Science.gov (United States)

    Sano, Yuko; Kandori, Akihiko; Shima, Keisuke; Yamaguchi, Yuki; Tsuji, Toshio; Noda, Masafumi; Higashikawa, Fumiko; Yokoe, Masaru; Sakoda, Saburo

    2016-06-01

    We propose a novel index of Parkinson's disease (PD) finger-tapping severity, called "PDFTsi," for quantifying the severity of symptoms related to the finger tapping of PD patients with high accuracy. To validate the efficacy of PDFTsi, the finger-tapping movements of normal controls and PD patients were measured by using magnetic sensors, and 21 characteristics were extracted from the finger-tapping waveforms. To distinguish motor deterioration due to PD from that due to aging, the aging effect on finger tapping was removed from these characteristics. Principal component analysis (PCA) was applied to the age-normalized characteristics, and principal components that represented the motion properties of finger tapping were calculated. Multiple linear regression (MLR) with stepwise variable selection was applied to the principal components, and PDFTsi was calculated. The calculated PDFTsi indicates that PDFTsi has a high estimation ability, namely a mean square error of 0.45. The estimation ability of PDFTsi is higher than that of the alternative method, MLR with stepwise regression selection without PCA, namely a mean square error of 1.30. This result suggests that PDFTsi can quantify PD finger-tapping severity accurately. Furthermore, the result of interpreting a model for calculating PDFTsi indicated that motion wideness and rhythm disorder are important for estimating PD finger-tapping severity.

  19. Robotic finger perturbation training improves finger postural steadiness and hand dexterity.

    Science.gov (United States)

    Yoshitake, Yasuhide; Ikeda, Atsutoshi; Shinohara, Minoru

    2018-02-01

    The purpose of the study was to understand the effect of robotic finger perturbation training on steadiness in finger posture and hand dexterity in healthy young adults. A mobile robotic finger training system was designed to have the functions of high-speed mechanical response, two degrees of freedom, and adjustable loading amplitude and direction. Healthy young adults were assigned to one of the three groups: random perturbation training (RPT), constant force training (CFT), and control. Subjects in RPT and CFT performed steady posture training with their index finger using the robot in different modes: random force in RPT and constant force in CFT. After the 2-week intervention period, fluctuations of the index finger posture decreased only in RPT during steady position-matching tasks with an inertial load. Purdue pegboard test score improved also in RPT only. The relative change in finger postural fluctuations was negatively correlated with the relative change in the number of completed pegs in the pegboard test in RPT. The results indicate that finger posture training with random mechanical perturbations of varying amplitudes and directions of force is effective in improving finger postural steadiness and hand dexterity in healthy young adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Viscoelastic fingering with a pulsed pressure signal

    International Nuclear Information System (INIS)

    Corvera Poire, E; Rio, J A del

    2004-01-01

    We derive a generalized Darcy's law in the frequency domain for a linear viscoelastic fluid flowing in a Hele-Shaw cell. This leads to an analytic expression for the dynamic permeability that has maxima which are several orders of magnitude larger than the static permeability. We then follow an argument of de Gennes (1987 Europhys. Lett. 2 195) to obtain the smallest possible finger width when viscoelasticity is important. Using this and a conservation law, we obtain the lowest bound for the width of a single finger displacing a viscoelastic fluid. When the driving force consists of a constant pressure gradient plus an oscillatory signal, our results indicate that the finger width varies in time following the frequency of the incident signal. Also, the amplitude of the finger width in time depends on the value of the dynamic permeability at the imposed frequency. When the finger is driven with a frequency that maximizes the permeability, variations in the amplitude are also maximized. This gives results that are very different for Newtonian and viscoelastic fluids. For the former ones the amplitude of the oscillation decays with frequency. For the latter ones on the other hand, the amplitude has maxima at the same frequencies that maximize the dynamic permeability

  1. Perceiving fingers in single-digit arithmetic problems

    Directory of Open Access Journals (Sweden)

    Ilaria eBerteletti

    2015-03-01

    Full Text Available In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense.

  2. Perceiving fingers in single-digit arithmetic problems.

    Science.gov (United States)

    Berteletti, Ilaria; Booth, James R

    2015-01-01

    In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense.

  3. Finger millet [Eleusine coracana (L.) Gaertn].

    Science.gov (United States)

    Ceasar, Stanislaus Antony; Ignacimuthu, Savarimuthu

    2015-01-01

    Millets are the primary food source for millions of people in tropical regions of the world supplying mineral nutrition and protein. In this chapter, we describe an optimized protocol for the Agrobacterium-mediated transformation of finger millet variety GPU 45. Agrobacterium strain LBA4404 harboring plasmid pCAMBIA1301 which contains hygromycin phosphotransferase (hph) as selectable marker gene and β-glucuronidase (GUS) as reporter gene has been used. This protocol utilizes the shoot apex explants for the somatic embryogenesis and regeneration of finger millet after the transformation by Agrobacterium. Desiccation of explants during cocultivation helps for the better recovery of transgenic plants. This protocol is very useful for the efficient production of transgenic plants in finger millet through Agrobacterium-mediated transformation.

  4. Fluctuation of biological rhythm in finger tapping

    Science.gov (United States)

    Yoshinaga, H.; Miyazima, S.; Mitake, S.

    2000-06-01

    By analyzing biological rhythms obtained from finger tapping, we have investigated the differences of two biological rhythms between healthy and handicapped persons caused by Parkinson, brain infraction, car accident and so on. In this study, we have observed the motion of handedness of all subjects and obtained a slope a which characterizes a power-law relation between frequency and amplitude of finger-tapping rhythm. From our results, we have estimated that the slope a=0.06 is a rough criterion in order to distinguish healthy and handicapped persons.

  5. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Takayuki Hori

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger‐arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3‐DOF fingers are attached to the end‐effector of a 6‐DOF arm to configure a multi‐finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi‐finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini‐max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi‐finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  6. Mechanisms of inhibition of zinc-finger transcription factors by selenium compounds ebselen and selenite.

    Science.gov (United States)

    Larabee, Jason L; Hocker, James R; Hanas, Jay S

    2009-03-01

    The anti-inflammatory selenium compounds, ebselen (2-phenyl-1,2-benzisoselenazol-3[2H]-one) and selenite, were found to alter the DNA binding mechanisms and structures of cysteine-rich zinc-finger transcription factors. As assayed by DNase I protection, DNA binding by TFIIIA (transcription factor IIIA, prototypical Cys(2)His(2) zinc finger protein), was inhibited by micromolar amounts of ebselen. In a gel shift assay, ebselen inhibited the Cys(2)His(2) zinc finger-containing DNA binding domain (DBD) of the NF-kappaB mediated transcription factor Sp1. Ebselen also inhibited DNA binding by the p50 subunit of the pro-inflammatory Cys-containing NF-kappaB transcription factor. Electrospray ionization mass spectrometry (ESI-MS) was utilized to elucidate mechanisms of chemical interaction between ebselen and a zinc-bound Cys(2)His(2) zinc finger polypeptide modeled after the third finger of Sp1 (Sp1-3). Exposing Sp1-3 to micromolar amounts of ebselen resulted in Zn(2+) release from this peptide and the formation of a disulfide bond by oxidation of zinc finger SH groups, the likely mechanism for DNA binding inhibition. Selenite was shown by ESI-MS to also eject zinc from Sp1-3 as well as induce disulfide bond formation through SH oxidation. The selenite-dependent inhibition/oxidation mechanism differed from that of ebselen by inducing the formation of a stable selenotrisulfide bond. Selenite-induced selenotrisulfide formation was dependent upon the structure of the Cys(2)His(2) zinc finger as alteration in the finger structure enhanced this reaction as well as selenite-dependent zinc release. Ebselen and selenite-dependent inhibition/oxidation of Cys-rich zinc finger proteins, with concomitant release of zinc and finger structural changes, points to mechanisms at the atomic and protein level for selenium-induced alterations in Cys-rich proteins, and possible amelioration of certain inflammatory, neurodegenerative, and oncogenic responses.

  7. The ascorbate peroxidase APX1 is a direct target of a zinc finger transcription factor ZFP36 and a late embryogenesis abundant protein OsLEA5 interacts with ZFP36 to co-regulate OsAPX1 in seed germination in rice.

    Science.gov (United States)

    Huang, Liping; Jia, Jing; Zhao, Xixi; Zhang, MengYao; Huang, Xingxiu; E Ji; Ni, Lan; Jiang, Mingyi

    2018-01-01

    Seed germination is a vital developmental process. Abscisic acid (ABA) is an essential repressor of seed germination, while ROS (reactive oxygen species) also plays a vital role in regulating seed germination. ABA could inhibit the production of ROS in seed germination, but the mechanism of ABA reduced ROS production in seed germination was hitherto unknown. Here, by ChIP (chromatin immunoprecipitation)-seq, we found that ZFP36, a rice zinc finger transcription factor, could directly bind to the promoter of OsAPX1, coding an ascorbate peroxidase (APX) which has the most affinity for H 2 O 2 (substrate; a type of ROS), and act as a transcriptional activator of OsAPX1 promoter. Moreover, ZFP36 could interact with a late embryogenesis abundant protein OsLEA5 to co-regulate the promoter activity of OsAPX1. The seed germination is highly inhibited in ZFP36 overexpression plants under ABA treatment, while an RNA interference (RNAi) mutant of OsLEA5 rice seeds were less sensitive to ABA, and exogenous ASC (ascorbate acid) could alleviate the inhibition induced by ABA. Thus, our conclusion is that OsAPX1 is a direct target of ZFP36 and OsLEA5 could interact with ZFP36 to co-regulate ABA-inhibited seed germination by controlling the expression of OsAPX1. Copyright © 2017. Published by Elsevier Inc.

  8. [Treatment of trigger finger with located needle knife].

    Science.gov (United States)

    Zhang, Qi-Feng; Yang, Jiang; Xi, Sheng-Hua

    2016-07-25

    To investigate the clinical effects of located needle knife in the treatment of trigger finger. The clinical data of 133 patients(145 fingers) with trigger finger underwent treatment with located needle knife from September 2010 to March 2014 were retrospectively analyzed. There were 37 males(40 fingers) and 96 females (105 fingers), aged from 18 to 71 years old with a mean of 51.8 years. Course of disease was from 1 to 19 months with an average of 8.2 months. Affected fingers included 82 thumbs, 12 index fingers, 11 middle fingers, 36 ring fingers, and 4 little fingers. According to the standard of Quinnell grade, 42 fingers were grade III, 92 fingers were grade IV, and 11 fingers were grade V. Firstly the double pipe gab was put into the distal edge of hypertrophic tendon sheath, then small knife needle was used to release the sheath proximally along the tendon line direction. The informations of wound healing and nerve injury, postoperative finger function, finger pain at 6 months were observed. The operation time was from 8 to 25 min with an average of 9.8 min. All the patients were followed up from 6 to 26 months with an average of 12.5 months. No complications such as the wound inflammation and seepage, vascular or nerve injuries were found. According to the standard of Quinnell grade, 123 fingers got excellent results, 15 good, 7 poor. It's a good choice to treat trigger finger with located needle knife in advantage of minimal invasion, simple safe operation, and it should be promoted in clinic.

  9. ANALYSIS WITH MSC ADAMS OF A 5-FINGER AND 3-PHALANX /FINGER UNDER-ACTUATEDMECHANICAL HAND

    Directory of Open Access Journals (Sweden)

    Gheorghe POPESCU

    2013-05-01

    Full Text Available This paper studies the analysis with MSC ADAMS of a 5-fingered and 3-phalanx/finger underactuatedmechanical hand, designed by the author to work on industrial robots. Moreover, in order to increasegrasping safety in the automated handling process, the author has fitted each finger with a locking sequence inthe final phase of grasping. Thus, the mechanism of mechanical hand is considered to be a mechanical systemand is treated like a set of rigid bodies connected by mechanical linkages and elastic elements. To model andsimulate this mechanism with MSC ADAMS programme, the author covered the following stages: constructionof the model, testing-simulation, validation, finishing, parameterization, and optimization

  10. Lead inhibition of DNA-binding mechanism of Cys(2)His(2) zinc finger proteins.

    Science.gov (United States)

    Hanas, J S; Rodgers, J S; Bantle, J A; Cheng, Y G

    1999-11-01

    The association of lead with chromatin in cells suggests that deleterious metal effects may in part be mediated through alterations in gene function. To elucidate if and how lead may alter DNA binding of cysteine-rich zinc finger proteins, lead ions were analyzed for their ability to alter the DNA binding mechanism of the Cys(2)His(2) zinc finger protein transcription factor IIIA (TFIIIA). As assayed by DNase I protection, the interaction of TFIIIA with the 50-bp internal control region of the 5S ribosomal gene was partially inhibited by 5 microM lead ions and completely inhibited by 10 to 20 microM lead ions. Preincubation of free TFIIIA with lead resulted in DNA-binding inhibition, whereas preincubation of a TFIIIA/5S RNA complex with lead did not result in DNA-binding inhibition. Because 5S RNA binds TFIIIA zinc fingers, this result is consistent with an inhibition mechanism via lead binding to zinc fingers. The complete loss of DNase I protection on the 5S gene indicates the mechanism of inhibition minimally involves the N-terminal fingers of TFIIIA. Inhibition was not readily reversible and occurred in the presence of an excess of beta-mercaptoethanol. Inhibition kinetics were fast, progressing to completion in approximately 5 min. Millimolar concentrations of sulfhydryl-specific arsenic ions were not inhibitory for TFIIIA binding. Micromolar concentrations of lead inhibited DNA binding by Sp1, another Cys(2)His(2) finger protein, but not by the nonfinger protein AP2. Inhibition of Cys(2)His(2) zinc finger transcription factors by lead ions at concentrations near those known to have deleterious physiological effects points to new molecular mechanisms for lead toxicity in promoting disease.

  11. Characterization of the SUMO-binding activity of the myeloproliferative and mental retardation (MYM-type zinc fingers in ZNF261 and ZNF198.

    Directory of Open Access Journals (Sweden)

    Catherine M Guzzo

    Full Text Available SUMO-binding proteins interact with SUMO modified proteins to mediate a wide range of functional consequences. Here, we report the identification of a new SUMO-binding protein, ZNF261. Four human proteins including ZNF261, ZNF198, ZNF262, and ZNF258 contain a stretch of tandem zinc fingers called myeloproliferative and mental retardation (MYM-type zinc fingers. We demonstrated that MYM-type zinc fingers from ZNF261 and ZNF198 are necessary and sufficient for SUMO-binding and that individual MYM-type zinc fingers function as SUMO-interacting motifs (SIMs. Our binding studies revealed that the MYM-type zinc fingers from ZNF261 and ZNF198 interact with the same surface on SUMO-2 recognized by the archetypal consensus SIM. We also present evidence that MYM-type zinc fingers in ZNF261 contain zinc, but that zinc is not required for SUMO-binding. Immunofluorescence microscopy studies using truncated fragments of ZNF198 revealed that MYM-type zinc fingers of ZNF198 are necessary for localization to PML-nuclear bodies (PML-NBs. In summary, our studies have identified and characterized the SUMO-binding activity of the MYM-type zinc fingers in ZNF261 and ZNF198.

  12. The Incidence of Finger Ridge Counts among the Christian ...

    African Journals Online (AJOL)

    user

    higher among the males than females, with sex difference significant ,they were compared with ... Finger prints were taken by a USB finger print reader (Biometric Scanner).According .... "Digital dermatoglyphics of three caste groups of Mysore.

  13. Viscous fingering of HCI through gastric mucin

    Science.gov (United States)

    Bhaskar, K. Ramakrishnan; Garik, Peter; Turner, Bradley S.; Bradley, James Douglas; Bansil, Rama; Stanley, H. Eugene; Lamont, J. Thomas

    1992-12-01

    THE HCI in the mammalian stomach is concentrated enough to digest the stomach itself, yet the gastric epithelium remains undamaged. One protective factor is gastric mucus, which forms a protective layer over the surface epithelium1-4 and acts as a diffusion barrier5,6 Bicarbonate ions secreted by the gastric epithelium7 are trapped in the mucus gel, establishing a gradient from pH 1-2 at the lumen to pH 6-7 at the cell surface8-10. How does HCI, secreted at the base of gastric glands by parietal cells, traverse the mucus layer without acidifying it? Here we demonstrate that injection of HCI through solutions of pig gastric mucin produces viscous fingering patterns11-18 dependent on pH, mucin concentration and acid flow rate. Above pH 4, discrete fingers are observed, whereas below pH 4, HCI neither penetrates the mucin solution nor forms fingers. Our in vitro results suggest that HCI secreted by the gastric gland can penetrate the mucus gel layer (pH 5-7) through narrow fingers, whereas HC1 in the lumen (pH 2) is prevented from diffusing back to the epithelium by the high viscosity of gastric mucus gel on the luminal side.

  14. Designing Fingers in Simulation based on Imprints

    DEFF Research Database (Denmark)

    Wolniakowski, Adam; Krüger, Norbert; Werner, Andrzej

    process of doing so. This method takes root in the idea of using the imprint to produce the finger geometry. We furthermore provide a verification of our newly introduced imprinting method and a comparison to the previously introduced parametrized geometry method. This verification is done through a set...

  15. Designing Fingers in Simulation based on Imprints

    DEFF Research Database (Denmark)

    Wiuf Schwartz, Lukas Christoffer Malte; Wolniakowski, Adam; Werner, Andrzej

    2017-01-01

    process of doing so. This method takes root in the idea of using the imprint to produce the finger geometry. We furthermore provide a verification of our newly introduced imprinting method and a comparison to the previously introduced parametrized geometry method. This verification is done through a set...

  16. Finger Search in Grammar-Compressed Strings

    DEFF Research Database (Denmark)

    Bille, Philip; Christiansen, Anders Roy; Cording, Patrick Hagge

    2016-01-01

    random access, that is, given a position in the original uncompressed string report the character at that position. In this paper we study the random access problem with the finger search property, that is, the time for a random access query should depend on the distance between a specified index f...

  17. Compact Tactile Sensors for Robot Fingers

    Science.gov (United States)

    Martin, Toby B.; Lussy, David; Gaudiano, Frank; Hulse, Aaron; Diftler, Myron A.; Rodriguez, Dagoberto; Bielski, Paul; Butzer, Melisa

    2004-01-01

    Compact transducer arrays that measure spatial distributions of force or pressure have been demonstrated as prototypes of tactile sensors to be mounted on fingers and palms of dexterous robot hands. The pressure- or force-distribution feedback provided by these sensors is essential for the further development and implementation of robot-control capabilities for humanlike grasping and manipulation.

  18. Clubbed fingers: the claws we lost?

    NARCIS (Netherlands)

    Brouwers, A.A.M.; Vermeij-Keers, C.; Zoelen, E.J.J. van; Gooren, L.J.G.

    2004-01-01

    Clubbed digits resemble the human embryonic fingers and toes, which took like the digits of a claw. Clubbed digits, thus, may represent the return of the embryonic claw and may even represent the claws man has lost during evolution, if ontogenesis realty recapitulates phylogenesis. We put forward

  19. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O’Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  20. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.J.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O'Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  1. Optical Myography: Detecting Finger Movements by Looking at the Forearm

    Directory of Open Access Journals (Sweden)

    Christian eNissler

    2016-04-01

    Full Text Available One of the crucial problems found in the scientific community of assistive / rehabilitation robotics nowadays is that of automatically detecting what a disabled subject (for instance, a hand amputee wants to do, exactly when she wants to do it and strictly for the time she wants to do it. This problem, commonly called intent detection, has traditionally been tackled using surface electromyography, a technique which suffers from a number of drawbacks, including the changes in the signal induced by sweat and muscle fatigue. With the advent of realistic, physically plausible augmented- and virtual-reality environments for rehabilitation, this approach does not suffice anymore. In this paper we explore a novel method to solve the problem, that we call Optical Myography (OMG. The idea is to visually inspect the human forearm (or stump to reconstruct what fingers are moving and to what extent. In a psychophysical experiment involving ten intact subjects, we used visual fiducial markers (AprilTags and a standard web-camera to visualize the deformations of the surface of the forearm, which then were mapped to the intended finger motions. As ground truth, a visual stimulus was used, avoiding the need for finger sensors (force/position sensors, datagloves, etc.. Two machine-learning approaches, a linear and a non-linear one, were comparatively tested in settings of increasing realism. The results indicate an average error in the range of 0.05 to 0.22 (root mean square error normalized over the signal range, in line with similar results obtained with more mature techniques such as electromyography. If further successfully tested in the large, this approach could lead to vision-based intent detection of amputees, with the main application of letting such disabled persons dexterously and reliably interact in an augmented- / virtual-reality setup.

  2. Linguistic and perceptual-motor contributions to the kinematic properties of the braille reading finger.

    Science.gov (United States)

    Hughes, Barry; Van Gemmert, Arend W A; Stelmach, George E

    2011-08-01

    Recordings of the dominant finger during the reading of braille sentences by experienced readers reveal that the velocity of the finger changes frequently during the traverse of a line of text. These changes, not previously reported, involve a multitude of accelerations and decelerations, as well as reversals of direction. We investigated the origin of these velocity intermittencies (as well as movement reversals) by asking readers to twice read out-loud or silently sentences comprising high- or low-frequency words which combined to make grammatical sentences that were either meaningful or nonmeaningful. In a control condition we asked braille readers to smoothly scan lines of braille comprised of meaningless cell combinations. Word frequency and re-reading each contribute to the kinematics of finger movements, but neither sentence meaning nor the mode of reading do so. The velocity intermittencies were so pervasive that they are not easily attributable either to linguistic processing, text familiarity, mode of reading, or to sensory-motor interactions with the textured patterns of braille, but seem integral to all braille finger movements except reversals. While language-related processing can affect the finger movements, the effects are superimposed on a highly intermittent velocity profile whose origin appears to lie in the motor control of slow movements. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Finger Angle-Based Hand Gesture Recognition for Smart Infrastructure Using Wearable Wrist-Worn Camera

    Directory of Open Access Journals (Sweden)

    Feiyu Chen

    2018-03-01

    Full Text Available The arising of domestic robots in smart infrastructure has raised demands for intuitive and natural interaction between humans and robots. To address this problem, a wearable wrist-worn camera (WwwCam is proposed in this paper. With the capability of recognizing human hand gestures in real-time, it enables services such as controlling mopping robots, mobile manipulators, or appliances in smart-home scenarios. The recognition is based on finger segmentation and template matching. Distance transformation algorithm is adopted and adapted to robustly segment fingers from the hand. Based on fingers’ angles relative to the wrist, a finger angle prediction algorithm and a template matching metric are proposed. All possible gesture types of the captured image are first predicted, and then evaluated and compared to the template image to achieve the classification. Unlike other template matching methods relying highly on large training set, this scheme possesses high flexibility since it requires only one image as the template, and can classify gestures formed by different combinations of fingers. In the experiment, it successfully recognized ten finger gestures from number zero to nine defined by American Sign Language with an accuracy up to 99.38%. Its performance was further demonstrated by manipulating a robot arm using the implemented algorithms and WwwCam to transport and pile up wooden building blocks.

  4. Ultrasound-Guided Hyaluronic Acid Injections for Trigger Finger: A Double-Blinded, Randomized Controlled Trial.

    Science.gov (United States)

    Liu, Ding-Hao; Tsai, Mei-Wun; Lin, Shan-Hui; Chou, Chen-Liang; Chiu, Jan-Wei; Chiang, Chao-Ching; Kao, Chung-Lan

    2015-12-01

    To investigate the effects of ultrasound-guided injections of hyaluronic acid (HA) versus steroid for trigger fingers in adults. Prospective, double-blinded, randomized controlled study. Tertiary care center. Subjects with a diagnosis of trigger finger (N=36; 39 affected digits) received treatment and were evaluated. Subjects were randomly assigned to HA and steroid injection groups. Both study medications were injected separately via ultrasound guidance with 1 injection. The classification of trigger grading, pain, functional disability, and patient satisfaction were evaluated before the injection and 3 weeks and 3 months after the injection. At 3 months, 12 patients (66.7%) in the HA group and 17 patients (89.5%) in the steroid group exhibited no triggering of the affected fingers (P=.124). The treatment results at 3 weeks and 3 months showed similar changes in the Quinnell scale (P=.057 and .931, respectively). A statistically significant interaction effect between group and time was found for visual analog scale (VAS) and Michigan Hand Outcome Questionnaire (MHQ) evaluation (Pinjection (steroid 0.5±1.1 vs HA 2.7±2.4; Pinjection of HA demonstrated promising results for the treatment of trigger fingers. The optimal frequency, dosage, and molecular weight of HA injections for trigger fingers deserve further investigation for future clinical applications. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Dorsal finger texture recognition: Investigating fixed-length SURF

    DEFF Research Database (Denmark)

    Hartung, Daniel; Kückelhahn, Jesper

    2012-01-01

    We seek to create fixed-length features from dorsal finger skin images extracted by the SURF interest point detector to combine it in the privacy enhancing helper data scheme. The source of the biometric samples is the GUC45 database which features finger vein, fingerprint and dorsal finger skin...

  6. Association Between Finger Clubbing and Chronic Lung Disease in ...

    African Journals Online (AJOL)

    Finger clubbed patients had higher risk of hypoxemia (46.7%), pulmonary hypertension (46.7%) and advanced disease in WHO stage III/ IV (91.7%) compared to non-finger clubbed patients. Finger clubbed patients had lower CD4 cells count and percentage (median 369cells, 13%) compared to non-clubbed patients ...

  7. Left hand finger force in violin playing: tempo, loudness, and finger differences.

    Science.gov (United States)

    Kinoshita, Hiroshi; Obata, Satoshi

    2009-07-01

    A three-dimensional force transducer was installed in the neck of a violin under the A string at the D5 position in order to study the force with which the violinist clamps the string against the fingerboard under normal playing conditions. Violinists performed repetitive sequences of open A- and fingered D-tones using the ring finger at tempi of 1, 2, 4, 8, and 16 notes/s at mezzo-forte. At selected tempi, the effects of dynamic level and the use of different fingers were investigated as well. The force profiles were clearly dependent on tempo and dynamic level. At slow tempi, the force profiles were characterized by an initial pulse followed by a level force to the end of the finger contact period. At tempi higher than 2 Hz, only pulsed profiles were observed. The peak force exceeded 4.5 N at 1 and 2 Hz and decreased to 1.7 N at 16 Hz. All force and impulse values were lower at softer dynamic levels, and when using the ring or little finger compared to the index finger.

  8. TIF1alpha: a possible link between KRAB zinc finger proteins and nuclear receptors

    DEFF Research Database (Denmark)

    Le Douarin, B; You, J; Nielsen, Anders Lade

    1998-01-01

    Ligand-induced gene activation by nuclear receptors (NRs) is thought to be mediated by transcriptional intermediary factors (TIFs), that interact with their ligand-dependent AF-2 activating domain. Included in the group of the putative AF-2 TIFs identified so far is TIF1alpha, a member of a new...... family of proteins which contains an N-terminal RBCC (RING finger-B boxes-coiled coil) motif and a C-terminal bromodomain preceded by a PHD finger. In addition to these conserved domains present in a number of transcriptional regulatory proteins, TIF1alpha was found to contain several protein......-protein interaction sites. Of these, one specifically interacts with NRs bound to their agonistic ligand and not with NR mutants that are defective in the AF-2 activity. Immediately adjacent to this 'NR box', TIF1alpha contains an interaction site for members of the chromatin organization modifier (chromo) family, HP...

  9. Analysis of prosody in finger braille using electromyography.

    Science.gov (United States)

    Miyagi, Manabi; Nishida, Masafumi; Horiuchi, Yasuo; Ichikawa, Akira

    2006-01-01

    Finger braille is one of the communication methods for the deaf blind. The interpreter types braille codes on the fingers of deaf blind. Finger braille seems to be the most suitable medium for real-time communication by its speed and accuracy of transmitting characters. We hypothesize that the prosody information exists in the time structure and strength of finger braille typing. Prosody is the paralinguistic information that has functions to transmit the sentence structure, prominence, emotions and other form of information in real time communication. In this study, we measured the surface electromyography (sEMG) of finger movement to analyze the typing strength of finger braille. We found that the typing strength increases at the beginning of a phrase and a prominent phrase. The result shows the possibility that the prosody in the typing strength of finger braille can be applied to create an interpreter system for the deafblind.

  10. A Diabetic Elderly Man with Finger Ulcer.

    Science.gov (United States)

    Mohamad, Noraini; Badrin, Salziyan; Wan Abdullah, Wan Noor Hasbee

    2018-03-01

    Fixed cutaneous sporotrichosis is a differential diagnosis that can be considered in diabetic patients who present with a poorly healing ulcer. Although its prevalence is low, it can occur in patients with immunocompromised status. Here we report a case of a 70-year-old man with diabetes mellitus who presented with a 1-month history of an unhealed ulcer over the tip of his left middle finger. He experienced a cat bite over his left middle finger 1 month prior to the appearance of the lesion. A skin biopsy revealed the presence of Sporothrix schenckii . Oral itraconazole 200 mg twice daily was started empirically and the patient showed marked improvement in the skin lesion after 2 months of therapy.

  11. Finger vein recognition with personalized feature selection.

    Science.gov (United States)

    Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Meng, Xianjing

    2013-08-22

    Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG). For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG.

  12. Finger Vein Recognition with Personalized Feature Selection

    Directory of Open Access Journals (Sweden)

    Xianjing Meng

    2013-08-01

    Full Text Available Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG. For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG.

  13. Finger Search in the Implicit Model

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Nielsen, Jesper Asbjørn Sindahl; Truelsen, Jakob

    2012-01-01

    , and delete in times $\\mathcal{O}(q(t))$, $\\mathcal{O}(q^{-1}(\\log n)\\log n)$, $\\mathcal{O}(\\log n)$, and $\\mathcal{O}(\\log n)$, respectively, for any q(t) = Ω(logt). Finally we show that the search operation must take Ω(logn) time for the special case where the finger is always changed to the element...

  14. Visual Foraging With Fingers and Eye Gaze

    Directory of Open Access Journals (Sweden)

    Ómar I. Jóhannesson

    2016-03-01

    Full Text Available A popular model of the function of selective visual attention involves search where a single target is to be found among distractors. For many scenarios, a more realistic model involves search for multiple targets of various types, since natural tasks typically do not involve a single target. Here we present results from a novel multiple-target foraging paradigm. We compare finger foraging where observers cancel a set of predesignated targets by tapping them, to gaze foraging where observers cancel items by fixating them for 100 ms. During finger foraging, for most observers, there was a large difference between foraging based on a single feature, where observers switch easily between target types, and foraging based on a conjunction of features where observers tended to stick to one target type. The pattern was notably different during gaze foraging where these condition differences were smaller. Two conclusions follow: (a The fact that a sizeable number of observers (in particular during gaze foraging had little trouble switching between different target types raises challenges for many prominent theoretical accounts of visual attention and working memory. (b While caveats must be noted for the comparison of gaze and finger foraging, the results suggest that selection mechanisms for gaze and pointing have different operational constraints.

  15. Fingering instabilities in bacterial community phototaxis

    Science.gov (United States)

    Vps, Ritwika; Man Wah Chau, Rosanna; Casey Huang, Kerwyn; Gopinathan, Ajay

    Synechocystis sp PCC 6803 is a phototactic cyanobacterium that moves directionally in response to a light source. During phototaxis, these bacterial communities show emergent spatial organisation resulting in the formation of finger-like projections at the propagating front. In this study, we propose an analytical model that elucidates the underlying physical mechanisms which give rise to these spatial patterns. We describe the migrating front during phototaxis as a one-dimensional curve by considering the effects of phototactic bias, diffusion and surface tension. By considering the propagating front as composed of perturbations to a flat solution and using linear stability analysis, we predict a critical bias above which the finger-like projections appear as instabilities. We also predict the wavelengths of the fastest growing mode and the critical mode above which the instabilities disappear. We validate our predictions through comparisons to experimental data obtained by analysing images of phototaxis in Synechocystis communities. Our model also predicts the observed loss of instabilities in taxd1 mutants (cells with inactive TaxD1, an important photoreceptor in finger formation), by considering diffusion in mutually perpendicular directions and a lower, negative bias.

  16. Fusarium verticillioides from finger millet in Uganda.

    Science.gov (United States)

    Saleh, Amgad A; Esele, J P; Logrieco, Antonio; Ritieni, Alberto; Leslie, John F

    2012-01-01

    Finger millet (Eleusine coracana) is a subsistence crop grown in Sub-Saharan Africa and the Indian Sub-continent. Fusarium species occurring on this crop have not been reported. Approximately 13% of the Fusarium isolates recovered from finger millet growing at three different locations in eastern Uganda belong to Fusarium verticillioides, and could produce up to 18,600 µg/g of total fumonisins when cultured under laboratory conditions. These strains are all genetically unique, based on AFLP analyses, and form fertile perithecia when crossed with the standard mating type tester strains for this species. All but one of the strains is female-fertile and mating-type segregates 13:20 Mat-1:Mat-2. Three new sequences of the gene encoding translation elongation factor 1-α were found within the population. These results indicate a potential health risk for infants who consume finger millet gruel as a weaning food, and are consistent with the hypothesis that F. verticillioides originated in Africa and not in the Americas, despite its widespread association with maize grown almost anywhere worldwide.

  17. Palm to Finger Ulnar Sensory Nerve Conduction.

    Science.gov (United States)

    Davidowich, Eduardo; Nascimento, Osvaldo J M; Orsini, Marco; Pupe, Camila; Pessoa, Bruno; Bittar, Caroline; Pires, Karina Lebeis; Bruno, Carlos; Coutinho, Bruno Mattos; de Souza, Olivia Gameiro; Ribeiro, Pedro; Velasques, Bruna; Bittencourt, Juliana; Teixeira, Silmar; Bastos, Victor Hugo

    2015-12-29

    Ulnar neuropathy at the wrist (UNW) is rare, and always challenging to localize. To increase the sensitivity and specificity of the diagnosis of UNW many authors advocate the stimulation of the ulnar nerve (UN) in the segment of the wrist and palm. The focus of this paper is to present a modified and simplified technique of sensory nerve conduction (SNC) of the UN in the wrist and palm segments and demonstrate the validity of this technique in the study of five cases of type III UNW. The SNC of UN was performed antidromically with fifth finger ring recording electrodes. The UN was stimulated 14 cm proximal to the active electrode (the standard way) and 7 cm proximal to the active electrode. The normal data from amplitude and conduction velocity (CV) ratios between the palm to finger and wrist to finger segments were obtained. Normal amplitude ratio was 1.4 to 0.76. Normal CV ratio was 0.8 to 1.23.We found evidences of abnormal SNAP amplitude ratio or substantial slowing of UN sensory fibers across the wrist in 5 of the 5 patients with electrophysiological-definite type III UNW.

  18. Palm to finger ulnar sensory nerve conduction

    Directory of Open Access Journals (Sweden)

    Eduardo Davidowich

    2015-12-01

    Full Text Available Ulnar neuropathy at the wrist (UNW is rare, and always challenging to localize. To increase the sensitivity and specificity of the diagnosis of UNW many authors advocate the stimulation of the ulnar nerve (UN in the segment of the wrist and palm. The focus of this paper is to present a modified and simplified technique of sensory nerve conduction (SNC of the UN in the wrist and palm segments and demonstrate the validity of this technique in the study of five cases of type III UNW. The SNC of UN was performed antidromically with fifth finger ring recording electrodes. The UN was stimulated 14 cm proximal to the active electrode (the standard way and 7 cm proximal to the active electrode. The normal data from amplitude and conduction velocity (CV ratios between the palm to finger and wrist to finger segments were obtained. Normal amplitude ratio was 1.4 to 0.76. Normal CV ratio was 0.8 to 1.23.We found evidences of abnormal SNAP amplitude ratio or substantial slowing of UN sensory fibers across the wrist in 5 of the 5 patients with electrophysiological-definite type III UNW.

  19. The creation of the artificial RING finger from the cross-brace zinc finger by α-helical region substitution

    International Nuclear Information System (INIS)

    Miyamoto, Kazuhide; Togiya, Kayo

    2010-01-01

    The creation of the artificial RING finger as ubiquitin-ligating enzyme (E3) has been demonstrated. In this study, by the α-helical region substitution between the EL5 RING finger and the Williams-Beuren syndrome transcription factor (WSTF) PHD finger, the artificial E3 (WSTF PHD R ING finger) was newly created. The experiments of the chemical modification of residues Cys and the circular dichroism spectra revealed that the WSTF PHD R ING finger binds two zinc atoms and adopts the zinc-dependent ordered-structure. In the substrate-independent ubiquitination assay, the WSTF PHD R ING finger functions as E3 and was poly- or mono-ubiquitinated. The present strategy is very simple and convenient, and consequently it might be widely applicable to the creation of various artificial E3 RING fingers with the specific ubiquitin-conjugating enzyme (E2)-binding capability.

  20. VISIONS FOR FOOTWEAR TIP SHAPE ACCORDING TO THE CONFIGURATION FINGER

    Directory of Open Access Journals (Sweden)

    MALCOCI Marina

    2015-05-01

    Full Text Available Compatibility between the consumer and the interior leg permanent footwear raises a number of issues. And any new form of footwear is time for a new silhouette last. Fashion is a factor in determining the shape of the last significant role. The most important influence on fashion in footwear that has at one time is found in peak shape. During registered a variety of forms leading to the last, for example, pointed, oval, round, square, asymmetrical, curved, trapezoidal, etc. Each has added a tip top recommended. The paper analyzes the morphofunctional characteristic, namely, finger configuration. The configuration of the fingers is determined from the positions of all the fingers of one another, as are six variants. Analysis of the shape and configuration of the arm fingers allow us to make the following recommendations to consumers: people showing finger configuration as in variant V and VI are advised not to wear pointy shoes because of the limited movement of the foot, which favors the diversion finger I exterior and deformed finger V; persons who fall within I-IV variant can procure pointy shoes; a round-tipped shoes, square, curved or asymmetric may be purchased by any consumer regardless of the configuration of the fingers; shoes with cut edge must be present only in garderopa people in variant I and II; consumers whose configuration is like finger-VI and III variants are awkwardly shaped fingers can buy shoes closed in the previous summer, but of different perforations or overlapping strips.

  1. Speed invariance of independent control of finger movements in pianists.

    Science.gov (United States)

    Furuya, Shinichi; Soechting, John F

    2012-10-01

    Independent control of finger movements characterizes skilled motor behaviors such as tool use and musical performance. The purpose of the present study was to identify the effect of movement frequency (tempo) on individuated finger movements in piano playing. Joint motion at the digits was recorded while 5 expert pianists were playing 30 excerpts from musical pieces with different fingering and key locations either at a predetermined normal tempo or as fast as possible. Principal component analysis and cluster analysis using an expectation-maximization algorithm determined three distinct patterns of finger movement coordination for a keypress with each of the index, middle, ring, and little fingers at each of the two tempi. The finger kinematics of each coordination pattern was overall similar across the tempi. Tone sequences assigned into each cluster were also similar for both tempi. A linear regression analysis determined no apparent difference in the amount of movement covariation between the striking and nonstriking fingers at both metacarpo-phalangeal and proximal-interphalangeal joints across the two tempi, which indicated no effect of tempo on independent finger movements in piano playing. In addition, the standard deviation of interkeystroke interval across strokes did not differ between the two tempi, indicating maintenance of rhythmic accuracy of keystrokes. Strong temporal constraints on finger movements during piano playing may underlie the maintained independent control of fingers over a wider range of tempi, a feature being likely to be specific to skilled pianists.

  2. The role of fingers in number processing in young children.

    Science.gov (United States)

    Lafay, Anne; Thevenot, Catherine; Castel, Caroline; Fayol, Michel

    2013-01-01

    The aim of the present study was to investigate the relationship between finger counting and numerical processing in 4-7-year-old children. Children were assessed on a variety of numerical tasks and we examined the correlations between their rates of success and their frequency of finger use in a counting task. We showed that children's performance on finger pattern comparison and identification tasks did not correlate with the frequency of finger use. However, this last variable correlated with the percentages of correct responses in an enumeration task (i.e., Give-N task), even when the age of children was entered as a covariate in the analysis. Despite this correlation, we showed that some children who never used their fingers in the counting task were able to perform optimally in the enumeration task. Overall, our results support the conclusion that finger counting is useful but not necessary to develop accurate symbolic numerical skills. Moreover, our results suggest that the use of fingers in a counting task is related to the ability of children in a dynamic enumeration task but not to static tasks involving recognition or comparison of finger patterns. Therefore, it could be that the link between fingers and numbers remain circumscribed to counting tasks and do not extent to static finger montring situations.

  3. The role of fingers in number processing in young children

    Directory of Open Access Journals (Sweden)

    Anne eLafay

    2013-07-01

    Full Text Available The aim of the present study was to investigate the relationship between finger counting and numerical processing in 4- to 7-year-old children. Children were assessed on a variety of numerical tasks and we examined the correlations between their rates of success and their frequency of finger use in a counting task. We showed that children’s performance on finger pattern comparison and identification tasks did not correlate with the frequency of finger use. However, this last variable correlated with the percentages of correct responses in an enumeration task (i.e., Give-N task, even when the age of children was entered as a covariate in the analysis. Despite this correlation, we showed that some children who never used their fingers in the counting task were able to perform optimally in the enumeration task. Overall, our results support the conclusion that finger counting is useful but not necessary to develop accurate symbolic numerical skills. Moreover, our results suggest that the use of fingers in a counting task is related to the ability of children in a dynamic enumeration task but not to static tasks involving recognition or comparison of finger patterns. Therefore, it could be that the link between fingers and numbers remain circumscribed to counting tasks and do not extent to static finger montring situations.

  4. Localized frustration and binding-induced conformational change in recognition of 5S RNA by TFIIIA zinc finger.

    Science.gov (United States)

    Tan, Cheng; Li, Wenfei; Wang, Wei

    2013-12-19

    Protein TFIIIA is composed of nine tandemly arranged Cys2His2 zinc fingers. It can bind either to the 5S RNA gene as a transcription factor or to the 5S RNA transcript as a chaperone. Although structural and biochemical data provided valuable information on the recognition between the TFIIIIA and the 5S DNA/RNA, the involved conformational motions and energetic factors contributing to the binding affinity and specificity remain unclear. In this work, we conducted MD simulations and MM/GBSA calculations to investigate the binding-induced conformational changes in the recognition of the 5S RNA by the central three zinc fingers of TFIIIA and the energetic factors that influence the binding affinity and specificity at an atomistic level. Our results revealed drastic interdomain conformational changes between these three zinc fingers, involving the exposure/burial of several crucial DNA/RNA binding residues, which can be related to the competition between DNA and RNA for the binding of TFIIIA. We also showed that the specific recognition between finger 4/finger 6 and the 5S RNA introduces frustrations to the nonspecific interactions between finger 5 and the 5S RNA, which may be important to achieve optimal binding affinity and specificity.

  5. An EMG Interface for the Control of Motion and Compliance of a Supernumerary Robotic Finger

    Science.gov (United States)

    Hussain, Irfan; Spagnoletti, Giovanni; Salvietti, Gionata; Prattichizzo, Domenico

    2016-01-01

    In this paper, we propose a novel electromyographic (EMG) control interface to control motion and joints compliance of a supernumerary robotic finger. The supernumerary robotic fingers are a recently introduced class of wearable robotics that provides users additional robotic limbs in order to compensate or augment the existing abilities of natural limbs without substituting them. Since supernumerary robotic fingers are supposed to closely interact and perform actions in synergy with the human limbs, the control principles of extra finger should have similar behavior as human’s ones including the ability of regulating the compliance. So that, it is important to propose a control interface and to consider the actuators and sensing capabilities of the robotic extra finger compatible to implement stiffness regulation control techniques. We propose EMG interface and a control approach to regulate the compliance of the device through servo actuators. In particular, we use a commercial EMG armband for gesture recognition to be associated with the motion control of the robotic device and surface one channel EMG electrodes interface to regulate the compliance of the robotic device. We also present an updated version of a robotic extra finger where the adduction/abduction motion is realized through ball bearing and spur gears mechanism. We have validated the proposed interface with two sets of experiments related to compensation and augmentation. In the first set of experiments, different bimanual tasks have been performed with the help of the robotic device and simulating a paretic hand since this novel wearable system can be used to compensate the missing grasping abilities in chronic stroke patients. In the second set, the robotic extra finger is used to enlarge the workspace and manipulation capability of healthy hands. In both sets, the same EMG control interface has been used. The obtained results demonstrate that the proposed control interface is intuitive and can

  6. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  7. Finger agnosia and cognitive deficits in patients with Alzheimer's disease.

    Science.gov (United States)

    Davis, Andrew S; Trotter, Jeffrey S; Hertza, Jeremy; Bell, Christopher D; Dean, Raymond S

    2012-01-01

    The purpose of this study was to examine the presence of finger agnosia in patients with Alzheimer's disease (AD) and to determine if level of finger agnosia was related to cognitive impairment. Finger agnosia is a sensitive measure of cerebral impairment and is associated with neurofunctional areas implicated in AD. Using a standardized and norm-referenced approach, results indicated that patients with AD evidenced significantly decreased performance on tests of bilateral finger agnosia compared with healthy age-matched controls. Finger agnosia was predictive of cognitive dysfunction on four of seven domains, including: Crystallized Language, Fluid Processing, Associative Learning, and Processing Speed. Results suggest that measures of finger agnosia, a short and simple test, may be useful in the early detection of AD.

  8. An fMRI study of finger tapping in children and adults.

    Science.gov (United States)

    Turesky, Ted K; Olulade, Olumide A; Luetje, Megan M; Eden, Guinevere F

    2018-04-02

    Functional brain imaging studies have characterized the neural bases of voluntary movement for finger tapping in adults, but equivalent information for children is lacking. When contrasted to adults, one would expect children to have relatively greater activation, reflecting compensation for an underdeveloped motor system combined with less experience in the execution of voluntary movement. To test this hypothesis, we acquired functional magnetic resonance imaging (fMRI) data on 17 healthy right-handed children (7.48 ± 0.66 years) and 15 adults (24.9 ± 2.9 years) while they performed an irregularly paced finger-tapping task in response to a visual cue (left- and right-hand examined separately). Whole-brain within-group analyses revealed that finger tapping in either age group and for either hand activated contralateral SM1, SMA, ipsilateral anterior cerebellum, and occipital cortices. We used an ANOVA factorial design to test for main effects of Age Group (children vs adults), Hand (left vs. right), and their interactions. For main effects of Age Group, children showed relatively greater activity in left SM1 (extending into bilateral SMA), and, surprisingly, adults exhibited relatively greater activity in right pre-SMA/SMA (extending into left pre-SMA/SMA), right lateral globus pallidus, left putamen, and right anterior cerebellum. The interaction of Age Group × Hand revealed that while both groups activated right SM1 during left finger tapping and exhibited signal decreases (i.e., below fixation baseline) during right finger tapping, both these responses were attenuated in children relative to adults. These data provide an important foundation by which to study children with motor disorders. © 2018 Wiley Periodicals, Inc.

  9. Finger Injuries in Football and Rugby.

    Science.gov (United States)

    Elzinga, Kate E; Chung, Kevin C

    2017-02-01

    Football and rugby athletes are at increased risk of finger injuries given the full-contact nature of these sports. Some players may return to play early with protective taping, splinting, and casting. Others require a longer rehabilitation period and prolonged time away from the field. The treating hand surgeon must weigh the benefits of early return to play for the current season and future playing career against the risks of reinjury and long-term morbidity, including post-traumatic arthritis and decreased range of motion and strength. Each player must be comprehensively assessed and managed with an individualized treatment plan. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Erosion waves: Transverse instabilities and fingering

    Science.gov (United States)

    Malloggi, F.; Lanuza, J.; Andreotti, B.; Clément, E.

    2006-09-01

    Two laboratory scale experiments of dry and underwater avalanches of non-cohesive granular materials are investigated. We trigger solitary waves and study the conditions under which the front is transversally stable. We show the existence of a linear instability followed by a coarsening dynamics and finally the onset of a fingering pattern. Due to the different operating conditions, both experiments strongly differ by the spatial and time scales involved. Nevertheless, the quantitative agreement between the stability diagram, the wavelengths selected and the avalanche morphology suggest a common scenario for an erosion/deposition process.

  11. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Vertical Finger Displacement Is Reduced in Index Finger Tapping During Repeated Bout Rate Enhancement.

    Science.gov (United States)

    Mora-Jensen, Mark Holten; Madeleine, Pascal; Hansen, Ernst Albin

    2017-10-01

    The present study analyzed (a) whether a recently reported phenomenon of repeated bout rate enhancement in finger tapping (i.e., a cumulating increase in freely chosen finger tapping frequency following submaximal muscle activation in the form of externally unloaded voluntary tapping) could be replicated and (b) the hypotheses that the faster tapping was accompanied by changed vertical displacement of the fingertip and changed peak force during tapping. Right-handed, healthy, and recreationally active individuals (n = 24) performed two 3-min index finger tapping bouts at freely chosen tapping frequency, separated by 10-min rest. The recently reported phenomenon of repeated bout rate enhancement was replicated. The faster tapping (8.8 ± 18.7 taps/min, corresponding to 6.0 ± 11.0%, p = .033) was accompanied by reduced vertical displacement (1.6 ± 2.9 mm, corresponding to 6.3 ± 14.9%, p = .012) of the fingertip. Concurrently, peak force was unchanged. The present study points at separate control mechanisms governing kinematics and kinetics during finger tapping.

  13. Extrinsic versus intrinsic hand muscle dominance in finger flexion.

    Science.gov (United States)

    Al-Sukaini, A; Singh, H P; Dias, J J

    2016-05-01

    This study aims to identify the patterns of dominance of extrinsic or intrinsic muscles in finger flexion during initiation of finger curl and mid-finger flexion. We recorded 82 hands of healthy individuals (18-74 years) while flexing their fingers and tracked the finger joint angles of the little finger using video motion tracking. A total of 57 hands (69.5%) were classified as extrinsic dominant, where the finger flexion was initiated and maintained at proximal interphalangeal and distal interphalangeal joints. A total of 25 (30.5%) were classified as intrinsic dominant, where the finger flexion was initiated and maintained at the metacarpophalangeal joint. The distribution of age, sex, dominance, handedness and body mass index was similar in the two groups. This knowledge may allow clinicians to develop more efficient rehabilitation regimes, since intrinsic dominant individuals would not initiate extrinsic muscle contraction till later in finger flexion, and might therefore be allowed limited early active motion. For extrinsic dominant individuals, by contrast, initial contraction of extrinsic muscles would place increased stress on the tendon repair site if early motion were permitted. © The Author(s) 2016.

  14. Tetanus following replantation of an amputated finger: a case report.

    Science.gov (United States)

    Hayashida, Kenji; Murakami, Chikako; Fujioka, Masaki

    2012-10-08

    Tetanus is an infectious disease caused by tetanus toxin produced by Clostridium tetani and induces severe neurological manifestations. We treated a patient who developed tetanus during hospitalization for replantation of an amputated finger. To the best of our knowledge, this is the first published case report of such an entity. A 49-year-old Japanese man had an amputation of his right middle finger at the distal interphalangeal joint region in an accident at work. His middle finger was successfully replanted, but his fingertip was partially necrotized because of crushing and so additional reconstruction with a reverse digital arterial flap was performed 15 days after the injury. Tetanus developed 21 days after replantation of the middle finger, but symptoms remitted via rapid diagnosis and treatment. In replantation after finger trauma with exposure of nerve and blood vessel bundles, concern over injuring nerves and blood vessels may prevent irrigation and debridement from being performed sufficiently; these treatments may have been insufficiently performed in this patient. It is likely that the replanted middle finger partially adhered, and Clostridium tetani colonized the partially necrotized region. Even when there is only limited soil contamination, administration of tetanus toxoid and anti-tetanus immunoglobulin is necessary when the fingers are injured outdoors and the finger nerves and blood vessels are exposed. The drugs should be administered just after replantation if the finger has been amputated. However, if clinicians pay attention to the possibility of tetanus development, treatment can be rapidly initiated.

  15. Tetanus following replantation of an amputated finger: a case report

    Directory of Open Access Journals (Sweden)

    Hayashida Kenji

    2012-10-01

    Full Text Available Abstract Introduction Tetanus is an infectious disease caused by tetanus toxin produced by Clostridium tetani and induces severe neurological manifestations. We treated a patient who developed tetanus during hospitalization for replantation of an amputated finger. To the best of our knowledge, this is the first published case report of such an entity. Case presentation A 49-year-old Japanese man had an amputation of his right middle finger at the distal interphalangeal joint region in an accident at work. His middle finger was successfully replanted, but his fingertip was partially necrotized because of crushing and so additional reconstruction with a reverse digital arterial flap was performed 15 days after the injury. Tetanus developed 21 days after replantation of the middle finger, but symptoms remitted via rapid diagnosis and treatment. Conclusions In replantation after finger trauma with exposure of nerve and blood vessel bundles, concern over injuring nerves and blood vessels may prevent irrigation and debridement from being performed sufficiently; these treatments may have been insufficiently performed in this patient. It is likely that the replanted middle finger partially adhered, and Clostridium tetani colonized the partially necrotized region. Even when there is only limited soil contamination, administration of tetanus toxoid and anti-tetanus immunoglobulin is necessary when the fingers are injured outdoors and the finger nerves and blood vessels are exposed. The drugs should be administered just after replantation if the finger has been amputated. However, if clinicians pay attention to the possibility of tetanus development, treatment can be rapidly initiated.

  16. EPR spectroscopic investigation of psoriatic finger nails.

    Science.gov (United States)

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Oxidation-Mediated Fingering in Liquid Metals

    Science.gov (United States)

    Eaker, Collin B.; Hight, David C.; O'Regan, John D.; Dickey, Michael D.; Daniels, Karen E.

    2017-10-01

    We identify and characterize a new class of fingering instabilities in liquid metals; these instabilities are unexpected due to the large interfacial tension of metals. Electrochemical oxidation lowers the effective interfacial tension of a gallium-based liquid metal alloy to values approaching zero, thereby inducing drastic shape changes, including the formation of fractals. The measured fractal dimension (D =1.3 ±0.05 ) places the instability in a different universality class than other fingering instabilities. By characterizing changes in morphology and dynamics as a function of droplet volume and applied electric potential, we identify the three main forces involved in this process: interfacial tension, gravity, and oxidative stress. Importantly, we find that electrochemical oxidation can generate compressive interfacial forces that oppose the tensile forces at a liquid interface. The surface oxide layer ultimately provides a physical and electrochemical barrier that halts the instabilities at larger positive potentials. Controlling the competition between interfacial tension and oxidative (compressive) stresses at the interface is important for the development of reconfigurable electronic, electromagnetic, and optical devices that take advantage of the metallic properties of liquid metals.

  18. Teleoperation of Robonaut Using Finger Tracking

    Science.gov (United States)

    Champoux, Rachel G.; Luo, Victor

    2012-01-01

    With the advent of new finger tracking systems, the idea of a more expressive and intuitive user interface is being explored and implemented. One practical application for this new kind of interface is that of teleoperating a robot. For humanoid robots, a finger tracking interface is required due to the level of complexity in a human-like hand, where a joystick isn't accurate. Moreover, for some tasks, using one's own hands allows the user to communicate their intentions more effectively than other input. The purpose of this project was to develop a natural user interface for someone to teleoperate a robot that is elsewhere. Specifically, this was designed to control Robonaut on the international space station to do tasks too dangerous and/or too trivial for human astronauts. This interface was developed by integrating and modifying 3Gear's software, which includes a library of gestures and the ability to track hands. The end result is an interface in which the user can manipulate objects in real time in the user interface. then, the information is relayed to a simulator, the stand in for Robonaut, at a slight delay.

  19. A springs actuated finger exoskeleton: From mechanical design to spring variables evaluation.

    Science.gov (United States)

    Bortoletto, Roberto; Mello, Ashley N; Piovesan, Davide

    2017-07-01

    In the context of post-stroke patients, suffering of hemiparesis of the hand, robot-aided neuro-motor rehabilitation allows for intensive rehabilitation treatments and quantitative evaluation of patients' progresses. This work presents the design and evaluation of a spring actuated finger exoskeleton. In particular, the spring variables and the interaction forces between the assembly and the hand were investigated, in order to assess the effectiveness of the proposed exoskeleton.

  20. Finger-like voids induced by viscous fingering during phase inversion of alumina/PES/NMP suspensions

    KAUST Repository

    Wang, Bo

    2012-07-01

    The formation mechanism of phase-inversion ceramic hollow fibre membranes has not been well understood. In this paper, we report on the formation of finger-like macrovoids during non-solvent-induced phase inversion of alumina/PES/NMP suspensions. A membrane structure without such finger-like macrovoids was observed when the suspension was slowly immersed into pure ethanol or a mixture of 70. wt% NMP and 30. wt% water, whereas finger-like macrovoids occurred when the suspension was slid into the non-solvents at higher speeds. We found that the formation process of finger-like macrovoids could be fully or partially reversed when nascent membranes were taken out from water shortly after immersion, depending on the duration of the immersion. Splitting of the fingers during the formation of the macrovoids was also observed during the phase inversion of two alumina/PES/NMP suspensions. These experimental observations were not predicted by current theories of finger-like macrovoid formation in polymer membranes, but appear to mimic the well-known viscous fingering phenomenon. We therefore propose that in the phase inversion of ceramic suspensions, the viscous fingering phenomenon is an important mechanism in the formation of finger-like voids. © 2012 Elsevier B.V.

  1. Transcriptome wide identification and characterization of starch branching enzyme in finger millet.

    Science.gov (United States)

    Tyagi, Rajhans; Tiwari, Apoorv; Garg, Vijay Kumar; Gupta, Sanjay

    2017-01-01

    Starch-branching enzymes (SBEs) are one of the four major enzyme classes involved in starch biosynthesis in plants and play an important role in determining the structure and physical properties of starch granules. Multiple SBEs are involved in starch biosynthesis in plants. Finger millet is calcium rich important serial crop belongs to grass family and the transcriptome data of developing spikes is available on NCBI. In this study it was try to find out the gene sequence of starch branching enzyme and annotate the sequence and submit the sequence for further use. Rice SBE sequence was taken as reference and for characterization of the sequence different in silico tools were used. Four domains were found in the finger millet Starch branching enzyme like alpha amylase catalytic domain from 925 to2172 with E value 0, N-terminal Early set domain from 634 to 915 with E value 1.62 e-42, Alpha amylase, C-terminal all-beta domain from 2224 to 2511 with E value 5.80e-24 and 1,4-alpha-glucan-branching enzyme from 421 to 2517 with E value 0. Major binding interactions with the GLC (alpha-d-glucose), CA (calcium ion), GOL (glycerol), TRS (2-amino-2-hydroxymethylpropane- 1, 3-diol), MG (magnesium ion) and FLC (citrate anion) are fond with different residues. It was found in the phylogenetic study of the finger millet SBE with the 6 species of grass family that two clusters were form A and B. In cluster A, finger millet showed closeness with Oryzasativa and Setariaitalica, Sorghum bicolour and Zea mays while cluster B was formed with Triticumaestivum and Brachypodium distachyon. The nucleotide sequence of Finger millet SBE was submitted to NCBI with the accession no KY648913 and protein structure of SBE of finger millet was also submitted in PMDB with the PMDB id - PM0080938. This research presents a comparative overview of Finger millet SBE and includes their properties, structural and functional characteristics, and recent developments on their post-translational regulation.

  2. Evaluation of the finger wrinkling test: A pilot study

    NARCIS (Netherlands)

    van Barneveld, S.; van der Palen, Jacobus Adrianus Maria; van Putten, Michel Johannes Antonius Maria

    2010-01-01

    Purpose: Tilt table testing mainly evaluates the systemic cardiovascular part of the autonomic nervous system, while it is assumed that the finger wrinkling test assesses the peripheral part of the autonomic nervous system. In this study we explored whether the finger wrinkling test could be a

  3. Automated Finger Spelling by Highly Realistic 3D Animation

    Science.gov (United States)

    Adamo-Villani, Nicoletta; Beni, Gerardo

    2004-01-01

    We present the design of a new 3D animation tool for self-teaching (signing and reading) finger spelling the first basic component in learning any sign language. We have designed a highly realistic hand with natural animation of the finger motions. Smoothness of motion (in real time) is achieved via programmable blending of animation segments. The…

  4. Population Structure and Diversity in Finger Millet (Eleusine coracana) Germplasm.

    Science.gov (United States)

    A genotypic analysis of 79 finger millet accessions (E. coracana subsp. coracana) from 11 African and 5 Asian countries, plus 14 wild E. coracana subsp. africana lines collected in Uganda and Kenya was conducted with 45 SSR markers distributed across the finger millet genome. Phylogenetic and popula...

  5. Quantitative assessment of finger motor performance: Normative data.

    Directory of Open Access Journals (Sweden)

    Alessio Signori

    Full Text Available Finger opposition movements are the basis of many daily living activities and are essential in general for manipulating objects; an engineered glove quantitatively assessing motor performance during sequences of finger opposition movements has been shown to be useful to provide reliable measures of finger motor impairment, even subtle, in subjects affected by neurological diseases. However, the obtained behavioral parameters lack published reference values.To determine mean values for different motor behavioral parameters describing the strategy adopted by healthy people in performing repeated sequences of finger opposition movements, examining associations with gender and age.Normative values for finger motor performance parameters were obtained on a sample of 255 healthy volunteers executing sequences of finger-to-thumb opposition movements, stratified by gender and over a wide range of ages. Touch duration, inter-tapping interval, movement rate, correct sequences (%, movements in advance compared with a metronome (% and inter-hand interval were assessed.Increasing age resulted in decreased movement speed, advance movements with respect to a cue, correctness of sequences, and bimanual coordination. No significant performance differences were found between male and female subjects except for the duration of the finger touch, the interval between two successive touches and their ratio.We report age- and gender-specific normal mean values and ranges for different parameters objectively describing the performance of finger opposition movement sequences, which may serve as useful references for clinicians to identify possible deficits in subjects affected by diseases altering fine hand motor skills.

  6. Experience of Percutaneous Trigger Finger Release under Local ...

    African Journals Online (AJOL)

    Background: Trigger finger is a common disorder of upper extremity. Majority of the patients can be treated conservatively but some resistant cases eventually need surgery. Aim: The aim of this study is to evaluate the results of percutaneous trigger finger release under local anesthesia. Subjects and Methods: This is a ...

  7. Robust finger vein ROI localization based on flexible segmentation.

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-10-24

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  8. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Directory of Open Access Journals (Sweden)

    Dong Sun Park

    2013-10-01

    Full Text Available Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  9. Finger vein extraction using gradient normalization and principal curvature

    Science.gov (United States)

    Choi, Joon Hwan; Song, Wonseok; Kim, Taejeong; Lee, Seung-Rae; Kim, Hee Chan

    2009-02-01

    Finger vein authentication is a personal identification technology using finger vein images acquired by infrared imaging. It is one of the newest technologies in biometrics. Its main advantage over other biometrics is the low risk of forgery or theft, due to the fact that finger veins are not normally visible to others. Extracting finger vein patterns from infrared images is the most difficult part in finger vein authentication. Uneven illumination, varying tissues and bones, and changes in the physical conditions and the blood flow make the thickness and brightness of the same vein different in each acquisition. Accordingly, extracting finger veins at their accurate positions regardless of their thickness and brightness is necessary for accurate personal identification. For this purpose, we propose a new finger vein extraction method which is composed of gradient normalization, principal curvature calculation, and binarization. As local brightness variation has little effect on the curvature and as gradient normalization makes the curvature fairly uniform at vein pixels, our method effectively extracts finger vein patterns regardless of the vein thickness or brightness. In our experiment, the proposed method showed notable improvement as compared with the existing methods.

  10. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-01-01

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769

  11. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording

    NARCIS (Netherlands)

    Imholz, B. P.; Langewouters, G. J.; van Montfrans, G. A.; Parati, G.; van Goudoever, J.; Wesseling, K. H.; Wieling, W.; Mancia, G.

    1993-01-01

    We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record

  12. 78 FR 68907 - Agency Information Collection (Hand and Finger Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-11-15

    ... Finger Conditions Disability Benefits Questionnaire) Under OMB Review AGENCY: Veterans Benefits... Control No. 2900- NEW (Hand and Finger Conditions Disability Benefits Questionnaire)'' in any... Benefits Questionnaire)''. SUPPLEMENTARY INFORMATION: Title: Hand and Finger Conditions Disability Benefits...

  13. NUMERICALLY DETERMINED TRANSPORT LAWS FOR FINGERING ('THERMOHALINE') CONVECTION IN ASTROPHYSICS

    International Nuclear Information System (INIS)

    Traxler, A.; Garaud, P.; Stellmach, S.

    2011-01-01

    We present the first three-dimensional simulations of fingering convection performed at parameter values approaching those relevant for astrophysics. Our simulations reveal the existence of simple asymptotic scaling laws for turbulent heat and compositional transport, which can be straightforwardly extrapolated from our numerically tractable values to the true astrophysical regime. Our investigation also indicates that thermo-compositional 'staircases', a key consequence of fingering convection in the ocean, cannot form spontaneously in the fingering regime in stellar interiors. Our proposed empirically determined transport laws thus provide simple prescriptions for mixing by fingering convection in a variety of astrophysical situations, and should, from here on, be used preferentially over older and less accurate parameterizations. They also establish that fingering convection does not provide sufficient extra-mixing to explain observed chemical abundances in red giant branch stars.

  14. A new algorithmic approach for fingers detection and identification

    Science.gov (United States)

    Mubashar Khan, Arslan; Umar, Waqas; Choudhary, Taimoor; Hussain, Fawad; Haroon Yousaf, Muhammad

    2013-03-01

    Gesture recognition is concerned with the goal of interpreting human gestures through mathematical algorithms. Gestures can originate from any bodily motion or state but commonly originate from the face or hand. Hand gesture detection in a real time environment, where the time and memory are important issues, is a critical operation. Hand gesture recognition largely depends on the accurate detection of the fingers. This paper presents a new algorithmic approach to detect and identify fingers of human hand. The proposed algorithm does not depend upon the prior knowledge of the scene. It detects the active fingers and Metacarpophalangeal (MCP) of the inactive fingers from an already detected hand. Dynamic thresholding technique and connected component labeling scheme are employed for background elimination and hand detection respectively. Algorithm proposed a new approach for finger identification in real time environment keeping the memory and time constraint as low as possible.

  15. Manipulation of viscous fingering in a radially tapered cell geometry

    Science.gov (United States)

    Bongrand, Grégoire; Tsai, Peichun Amy

    2018-06-01

    When a more mobile fluid displaces another immiscible one in a porous medium, viscous fingering propagates with a partial sweep, which hinders oil recovery and soil remedy. We experimentally investigate the feasibility of tuning such fingering propagation in a nonuniform narrow passage with a radial injection, which is widely used in various applications. We show that a radially converging cell can suppress the common viscous fingering observed in a uniform passage, and a full sweep of the displaced fluid is then achieved. The injection flow rate Q can be further exploited to manipulate the viscous fingering instability. For a fixed gap gradient α , our experimental results show a full sweep at a small Q but partial displacement with fingering at a sufficient Q . Finally, by varying α , we identify and characterize the variation of the critical threshold between stable and unstable displacements. Our experimental results reveal good agreement with theoretical predictions by a linear stability analysis.

  16. Development of a CPM Machine for Injured Fingers.

    Science.gov (United States)

    Fu, Yili; Zhang, Fuxiang; Ma, Xin; Meng, Qinggang

    2005-01-01

    Human fingers are easy to be injured. A CPM machine is a mechanism based on the rehabilitation theory of continuous passive motion (CPM). To develop a CPM machine for the clinic application in the rehabilitation of injured fingers is a significant task. Therefore, based on the theories of evidence based medicine (EBM) and CPM, we've developed a set of biomimetic mechanism after modeling the motions of fingers and analyzing its kinematics and dynamics analysis. We also design an embedded operating system based on ARM (a kind of 32-bit RISC microprocessor). The equipment can achieve the precise control of moving scope of fingers, finger's force and speed. It can serves as a rational checking method and a way of assessment for functional rehabilitation of human hands. Now, the first prototype has been finished and will start the clinical testing in Harbin Medical University shortly.

  17. Innervated boomerang flap for finger pulp reconstruction.

    Science.gov (United States)

    Chen, Shao-Liang; Chiou, Tai-Fung

    2007-11-01

    The boomerang flap originates from the dorsolateral aspect of the proximal phalanx of an adjacent digit and is supplied by the retrograde blood flow through the vascular arcades between the dorsal and palmar digital arteries. To provide sensation of the boomerang flap for finger pulp reconstruction, the dorsal sensory branch of the proper digital nerve and the superficial sensory branch of the corresponding radial or ulnar nerve are included within the skin flap. After transfer of the flap to the injured site, epineural neurorrhaphies are done between the digital nerves of the pulp and the sensory branches of the flap. We used this sensory flap in five patients, with more than 1 year follow-up, and all patients achieved measurable two-points discrimination. The boomerang flap not only preserves the proper palmar digital artery but also provides an extended and innervated skin paddle. It seems to be an alternative choice for one-stage reconstruction of major pulp defect.

  18. Finger-like voids induced by viscous fingering during phase inversion of alumina/PES/NMP suspensions

    KAUST Repository

    Wang, Bo; Lai, Zhiping

    2012-01-01

    membrane structure without such finger-like macrovoids was observed when the suspension was slowly immersed into pure ethanol or a mixture of 70. wt% NMP and 30. wt% water, whereas finger-like macrovoids occurred when the suspension was slid into the non

  19. The Zinc Finger of Prolyl Hydroxylase Domain Protein 2 Is Essential for Efficient Hydroxylation of Hypoxia-Inducible Factor α.

    Science.gov (United States)

    Arsenault, Patrick R; Song, Daisheng; Chung, Yu Jin; Khurana, Tejvir S; Lee, Frank S

    2016-09-15

    Prolyl hydroxylase domain protein 2 (PHD2) (also known as EGLN1) is a key oxygen sensor in mammals that posttranslationally modifies hypoxia-inducible factor α (HIF-α) and targets it for degradation. In addition to its catalytic domain, PHD2 contains an evolutionarily conserved zinc finger domain, which we have previously proposed recruits PHD2 to the HSP90 pathway to promote HIF-α hydroxylation. Here, we provide evidence that this recruitment is critical both in vitro and in vivo We show that in vitro, the zinc finger can function as an autonomous recruitment domain to facilitate interaction with HIF-α. In vivo, ablation of zinc finger function by a C36S/C42S Egln1 knock-in mutation results in upregulation of the erythropoietin gene, erythrocytosis, and augmented hypoxic ventilatory response, all hallmarks of Egln1 loss of function and HIF stabilization. Hence, the zinc finger ordinarily performs a critical positive regulatory function. Intriguingly, the function of this zinc finger is impaired in high-altitude-adapted Tibetans, suggesting that their adaptation to high altitude may, in part, be due to a loss-of-function EGLN1 allele. Thus, these findings have important implications for understanding both the molecular mechanism of the hypoxic response and human adaptation to high altitude. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Convergent solid-phase and solution approaches in the synthesis of the cysteine-rich Mdm2 RING finger domain.

    Science.gov (United States)

    Vasileiou, Zoe; Barlos, Kostas; Gatos, Dimitrios

    2009-12-01

    The RING finger domain of the Mdm2, located at the C-terminus of the protein, is necessary for regulation of p53, a tumor suppressor protein. The 48-residues long Mdm2 peptide is an important target for studying its interaction with small anticancer drug candidates. For the chemical synthesis of the Mdm2 RING finger domain, the fragment condensation on solid-phase and the fragment condensation in solution were studied. The latter method was performed using either protected or free peptides at the C-terminus as the amino component. Best results were achieved using solution condensation where the N-component was applied with the C-terminal carboxyl group left unprotected. The developed method is well suited for large-scale synthesis of Mdm2 RING finger domain, combining the advantages of both solid-phase and solution synthesis. (c) 2009 European Peptide Society and John Wiley & Sons, Ltd.

  1. Torque control of underactuated tendon-driven fingers

    Directory of Open Access Journals (Sweden)

    M. E. Abdallah

    2011-02-01

    Full Text Available Given an underactuated tendon-driven finger, the finger posture is underdetermined and can move freely ("flop" in a region of slack tendons. This work shows that such an underactuated finger can be operated in tendon force control (rather than position control with effective performance. The force control eliminates the indeterminate slack while commanding a parameterized space of desired torques. The torque will either push the finger to the joint limits or wrap around an external object with variable torque – behavior that is sufficient for primarily gripping fingers. In addition, introducing asymmetric joint radii to the design allows the finger to command an expanded range of joint torques and to scan an expanded set of external surfaces. This study is motivated by the design and control of the secondary fingers of the NASA-GM R2 humanoid hand.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  2. A hierarchical classification method for finger knuckle print recognition

    Science.gov (United States)

    Kong, Tao; Yang, Gongping; Yang, Lu

    2014-12-01

    Finger knuckle print has recently been seen as an effective biometric technique. In this paper, we propose a hierarchical classification method for finger knuckle print recognition, which is rooted in traditional score-level fusion methods. In the proposed method, we firstly take Gabor feature as the basic feature for finger knuckle print recognition and then a new decision rule is defined based on the predefined threshold. Finally, the minor feature speeded-up robust feature is conducted for these users, who cannot be recognized by the basic feature. Extensive experiments are performed to evaluate the proposed method, and experimental results show that it can achieve a promising performance.

  3. The relation between the anthropometric characteristics of fingers and cancer

    Directory of Open Access Journals (Sweden)

    Omid Mardanshahi

    2017-07-01

    Full Text Available Anthropometry is a science of human body measurement that could be used for manufacturing artificial limbs or prosthesis, investigating body differences between populations, utilizing in forensics and criminology, or even in the diagnosis of some diseases. Two of the most important anthropometric characteristics are dermatoglyphic patterns and finger length. Many studies have evaluated the relation between these two characteristics in different diseases such as cancers. It assumed that dermatoglyphic patterns and finger length could be used as predictors of some cancers such as gastric, ovarian, prostate, testicular, and breast cancers. In this review, we evaluated the relation between dermatoglyphic variability and finger length in different cancers more precisely.

  4. Dermal pocketing following distal finger replantation.

    Science.gov (United States)

    Puhaindran, Mark E; Paavilainen, Pasi; Tan, David M K; Peng, Yeong Pin; Lim, Aymeric Y T

    2010-08-01

    Replantation is an ideal technique for reconstruction following fingertip amputation as it provides 'like for like' total reconstruction of the nail complex, bone pulp tissue and skin with no donor-site morbidity. However, fingertips are often not replanted because veins cannot be found or are thought to be too small to repair. Attempts at 'cap-plasty' or pocketing of replanted tips with and without microvascular anastomosis have been done in the past with varying degrees of success. We prospectively followed up a group of patients who underwent digital replantation and dermal pocketing in the palm to evaluate the outcome of this procedure. There were 10 patients with 14 amputated digits (two thumbs, five index, four middle, two ring and one little) who underwent dermal pocketing of the amputated digit following replantation. Among the 14 digits that were treated with dermal pocketing, 11 survived completely, one had partial atrophy and two were completely lost. Complications encountered included finger stiffness (two patients) and infection of the replanted fingertip with osteomyelitis of the distal phalanx (one patient). We believe that this technique can help increase the chance of survival for distal replantation with an acceptable salvage rate of 85% in our series. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Low Power Measurements on a Finger Drift Tube Linac

    CERN Document Server

    Schempp, A

    2004-01-01

    The efficiency of RFQs decreases at higher particle energies. The DTL structures used in this energy regions have a defocusing influence on the beam. To achieve a focusing effect, fingers with quadrupole symmetry were added to the drift tubes. Driven by the same power supply as the drift tubes, the fingers do not need an additional power source or feedthrough. Beam dynamics have been studied with PARMTEQ . Detailed analysis of the field distribution was done and the geometry of the finger array has been optimized with respect to beam dynamics. A spiral loaded cavity with finger drift tubes was built up and low power measurements were done. In this contribution, the results of the rf simulating with Microwave Studio are shown in comparison with bead pertubation measurement on a prototype cavity.

  6. Finger Vein Recognition Based on Local Directional Code

    Science.gov (United States)

    Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2012-01-01

    Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP. PMID:23202194

  7. Variability and trait relationships among finger millet accessions in ...

    African Journals Online (AJOL)

    ACSS

    A total of 100 accessions were evaluated for morpho-agronomic characters in a ... head blast incidence, productive tillers plant-1 and grain yield. ... Introduction ... protein, iron and calcium, finger millet ... collection and maintenance has been.

  8. Finger Vein Recognition Based on Local Directional Code

    Directory of Open Access Journals (Sweden)

    Rongyang Xiao

    2012-11-01

    Full Text Available Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP, Local Derivative Pattern (LDP and Local Line Binary Pattern (LLBP. However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD, this paper represents a new direction based local descriptor called Local Directional Code (LDC and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP.

  9. Experience of Percutaneous Trigger Finger Release under Local ...

    African Journals Online (AJOL)

    New Delhi, India. ... This procedure is easy, quicker, less complications and economical with good results. ... Sahu and Gupta: Trigger finger release under local anesthesia .... the most cost-effective treatment is two trials of corticosteroid.

  10. The effects of vibration-reducing gloves on finger vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new

  11. Characterization of Antifungal Natural Products Isolated from Endophytic Fungi of Finger Millet (Eleusine coracana).

    Science.gov (United States)

    Mousa, Walaa Kamel; Schwan, Adrian L; Raizada, Manish N

    2016-09-03

    Finger millet is an ancient African-Indian crop that is resistant to many pathogens including the fungus, Fusarium graminearum. We previously reported the first isolation of putative fungal endophytes from finger millet and showed that the crude extracts of four strains had anti-Fusarium activity. However, active compounds were isolated from only one strain. The objectives of this study were to confirm the endophytic lifestyle of the three remaining anti-Fusarium isolates, to identify the major underlying antifungal compounds, and to initially characterize the mode(s) of action of each compound. Results of confocal microscopy and a plant disease assay were consistent with the three fungal strains behaving as endophytes. Using bio-assay guided fractionation and spectroscopic structural elucidation, three anti-Fusarium secondary metabolites were purified and characterized. These molecules were not previously reported to derive from fungi nor have antifungal activity. The purified antifungal compounds were: 5-hydroxy 2(3H)-benzofuranone, dehydrocostus lactone (guaianolide sesquiterpene lactone), and harpagoside (an iridoide glycoside). Light microscopy and vitality staining were used to visualize the in vitro interactions between each compound and Fusarium; the results suggested a mixed fungicidal/fungistatic mode of action. We conclude that finger millet possesses fungal endophytes that can synthesize anti-fungal compounds not previously reported as bio-fungicides against F. graminearum.

  12. Characterization of Antifungal Natural Products Isolated from Endophytic Fungi of Finger Millet (Eleusine coracana

    Directory of Open Access Journals (Sweden)

    Walaa Kamel Mousa

    2016-09-01

    Full Text Available Finger millet is an ancient African-Indian crop that is resistant to many pathogens including the fungus, Fusarium graminearum. We previously reported the first isolation of putative fungal endophytes from finger millet and showed that the crude extracts of four strains had anti-Fusarium activity. However, active compounds were isolated from only one strain. The objectives of this study were to confirm the endophytic lifestyle of the three remaining anti-Fusarium isolates, to identify the major underlying antifungal compounds, and to initially characterize the mode(s of action of each compound. Results of confocal microscopy and a plant disease assay were consistent with the three fungal strains behaving as endophytes. Using bio-assay guided fractionation and spectroscopic structural elucidation, three anti-Fusarium secondary metabolites were purified and characterized. These molecules were not previously reported to derive from fungi nor have antifungal activity. The purified antifungal compounds were: 5-hydroxy 2(3H-benzofuranone, dehydrocostus lactone (guaianolide sesquiterpene lactone, and harpagoside (an iridoide glycoside. Light microscopy and vitality staining were used to visualize the in vitro interactions between each compound and Fusarium; the results suggested a mixed fungicidal/fungistatic mode of action. We conclude that finger millet possesses fungal endophytes that can synthesize anti-fungal compounds not previously reported as bio-fungicides against F. graminearum.

  13. Fusion of geometric and texture features for finger knuckle surface recognition

    Directory of Open Access Journals (Sweden)

    K. Usha

    2016-03-01

    Full Text Available Hand-based biometrics plays a significant role in establishing security for real-time environments involving human interaction and is found to be more successful in terms of high speed and accuracy. This paper investigates on an integrated approach for personal authentication using Finger Back Knuckle Surface (FBKS based on two methodologies viz., Angular Geometric Analysis based Feature Extraction Method (AGFEM and Contourlet Transform based Feature Extraction Method (CTFEM. Based on these methods, this personal authentication system simultaneously extracts shape oriented feature information and textural pattern information of FBKS for authenticating an individual. Furthermore, the proposed geometric and textural analysis methods extract feature information from both proximal phalanx and distal phalanx knuckle regions (FBKS, while the existing works of the literature concentrate only on the features of proximal phalanx knuckle region. The finger joint region found nearer to the tip of the finger is called distal phalanx region of FBKS, which is a unique feature and has greater potentiality toward identification. Extensive experiments conducted using newly created database with 5400 FBKS images and the obtained results infer that the integration of shape oriented features with texture feature information yields excellent accuracy rate of 99.12% with lowest equal error rate of 1.04%.

  14. Robotic Hand with Flexible Fingers for Grasping Cylindrical Objects

    OpenAIRE

    柴田, 瑞穂

    2015-01-01

    In this manuscript, a robotic hand for grasping a cylindrical object is proposed. This robotic hand has flexible fingers that can hold a cylindrical object during moving. We introduce a grasping strategy for a cylindrical object in terms of state transition graph. In this strategy the robotic hand picks up the cylindrical object utilizing a suction device before the hand grasp the object. We also design the flexible fingers; then, we investigate the validity of this robotic hand via several e...

  15. Finger blood content, light transmission, and pulse oximetry errors.

    Science.gov (United States)

    Craft, T M; Lawson, R A; Young, J D

    1992-01-01

    The changes in light emitting diode current necessary to maintain a constant level of light incident upon a photodetector were measured in 20 volunteers at the two wavelengths employed by pulse oximeters. Three states of finger blood content were assessed; exsanguinated, hyperaemic, and normal. The changes in light emitting diode current with changes in finger blood content were small and are not thought to represent a significant source of error in saturation as measured by pulse oximetry.

  16. Compression and flexural properties of finger jointed mango wood sections

    OpenAIRE

    Kumar, V.S Kishan; Sharma, C.M; Gupta, Sachin

    2014-01-01

    In this paper, an attempt was made to assess the effectiveness of finger jointing in utilising mango wood sections for various end uses like furniture. The study was based on the estimation of Modulus of elasticity and Modulus of rupture under static bending and Maximum Crushing Stress and Modulus of elasticity under compression parallel to grain of finger jointed sections and comparing them with the values measured for clear wood sections from the same lot. For joining the sections, the Poly...

  17. Elastic fingering in rotating Hele-Shaw flows

    KAUST Repository

    Carvalho, Gabriel D.

    2014-05-21

    The centrifugally driven viscous fingering problem arises when two immiscible fluids of different densities flow in a rotating Hele-Shaw cell. In this conventional setting an interplay between capillary and centrifugal forces makes the fluid-fluid interface unstable, leading to the formation of fingered structures that compete dynamically and reach different lengths. In this context, it is known that finger competition is very sensitive to changes in the viscosity contrast between the fluids. We study a variant of such a rotating flow problem where the fluids react and produce a gellike phase at their separating boundary. This interface is assumed to be elastic, presenting a curvature-dependent bending rigidity. A perturbative weakly nonlinear approach is used to investigate how the elastic nature of the interface affects finger competition events. Our results unveil a very different dynamic scenario, in which finger length variability is not regulated by the viscosity contrast, but rather determined by two controlling quantities: a characteristic radius and a rigidity fraction parameter. By properly tuning these quantities one can describe a whole range of finger competition behaviors even if the viscosity contrast is kept unchanged. © 2014 American Physical Society.

  18. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  19. Elastic fingering in rotating Hele-Shaw flows

    KAUST Repository

    Carvalho, Gabriel D.; Gadê lha, Hermes; Miranda, José A.

    2014-01-01

    The centrifugally driven viscous fingering problem arises when two immiscible fluids of different densities flow in a rotating Hele-Shaw cell. In this conventional setting an interplay between capillary and centrifugal forces makes the fluid-fluid interface unstable, leading to the formation of fingered structures that compete dynamically and reach different lengths. In this context, it is known that finger competition is very sensitive to changes in the viscosity contrast between the fluids. We study a variant of such a rotating flow problem where the fluids react and produce a gellike phase at their separating boundary. This interface is assumed to be elastic, presenting a curvature-dependent bending rigidity. A perturbative weakly nonlinear approach is used to investigate how the elastic nature of the interface affects finger competition events. Our results unveil a very different dynamic scenario, in which finger length variability is not regulated by the viscosity contrast, but rather determined by two controlling quantities: a characteristic radius and a rigidity fraction parameter. By properly tuning these quantities one can describe a whole range of finger competition behaviors even if the viscosity contrast is kept unchanged. © 2014 American Physical Society.

  20. A comprehensive assessment of cardiovascular autonomic control using photoplethysmograms recorded from the earlobe and fingers

    International Nuclear Information System (INIS)

    Kiselev, A R; Mironov, S A; Karavaev, A S; Kulminskiy, D D; Prokhorov, M D; Skazkina, V V; Borovkova, E I; Ponomarenko, V I; Shvartz, V A

    2016-01-01

    We compare the spectral indices of photoplethysmogram variability (PPGV) estimated using photoplethysmograms recorded from the earlobe and the middle fingers of the right and left hand and analyze their correlation with similar indices of heart rate variability (HRV) in 30 healthy subjects (26 men) aged 27 (25, 29) years (median with inter-quartile ranges) at rest and under the head-up tilt test. The following spectral indices of PPGV and HRV were compared: mean heart rate (HR), total spectral power (TP), high-frequency (HF) and low-frequency (LF) ranges of TP in percents (HF% and LF%), LF/HF ratio, and spectral coherence. We assess also the index S of synchronization between the LF oscillations in HRV and PPGV. The constancy of blood pressure (BP) and moderate increase of HR under the tilt test indicate the presence of fast processes of cardiovascular adaptation with the increase of the sympathetic activity in studied healthy subjects. The impact of respiration on the PPGV spectrum (accessed by HF%) is less than on the HRV spectrum. It is shown that the proportion of sympathetic vascular activity (accessed by LF%) is constant in the PPGV of three analyzed PPGs during the tilt test. The PPGV for the ear PPG was less vulnerable to breathing influence accessed by HF% (independently from body position) than for PPGs from fingers. We reveal the increase of index S under the tilt test indicating the activation of interaction between the heart and distal vessels. The PPGV spectra for finger PPGs from different hands are highly coherent, but differ substantially from the PPGV spectrum for the ear PPG. We conclude that joint analysis of frequency components of PPGV (for the earlobe and finger PPGs of both hands) and HRV and assessment of their synchronization provide additional information about cardiovascular autonomic control. (paper)

  1. Surgery for Dupuytren's contracture of the fingers.

    Science.gov (United States)

    Rodrigues, Jeremy N; Becker, Giles W; Ball, Cathy; Zhang, Weiya; Giele, Henk; Hobby, Jonathan; Pratt, Anna L; Davis, Tim

    2015-12-09

    Dupuytren's disease is a benign fibroproliferative disorder that causes the fingers to be drawn into the palm via formation of new tissue under the glabrous skin of the hand. This disorder causes functional limitations, but it can be treated through a variety of surgical techniques. As a chronic condition, it tends to recur. To assess the benefits and harms of different surgical procedures for treatment of Dupuytren's contracture of the index, middle, ring and little fingers. We initially searched the following databases on 17 September 2012, then re-searched them on 10 March 2014 and on 20 May 2015: the Cochrane Central Register of Controlled Trials (CENTRAL), The Cochrane Library, the British Nursing Index and Archive (BNI), the Cumulative Index to Nursing and Allied Health Literature (CINAHL), EMBASE, the Latin American Caribbean Health Sciences Literature (LILACS), Ovid MEDLINE, Ovid MEDLINE-In-Process and Other Non-Indexed Citations, ProQuest (ABI/INFORM Global and Dissertations & Theses), the Institute for Scientific Information (ISI) Web of Science and clinicaltrials.gov. We reviewed the reference lists of short-listed articles to identify additional suitable studies. We included randomised clinical trials and controlled clinical trials in which groups received surgical intervention for Dupuytren's disease of the index, middle, ring or little finger versus control, or versus another intervention (surgical or otherwise). We excluded the thumb, as cords form on the radial aspect of the thumb and thus are not readily accessible in terms of angular deformity. Furthermore, thumb disease is rare. A minimum of two review authors independently reviewed search results to select studies for inclusion by using pre-specified criteria, assessed risk of bias of included studies and extracted data from included studies.We grouped outcomes into the following categories: (1) hand function, (2) other patient-reported outcomes (e.g. satisfaction, pain), (3) early objective

  2. Evaluation of finger millet incorporated noodles for nutritive value and glycemic index

    OpenAIRE

    Shukla, Kamini; Srivastava, Sarita

    2011-01-01

    The present study was undertaken to develop finger millet incorporated noodles for diabetic patients. Finger millet variety VL-149 was taken. The finger millet flour and refined wheat flour (RWF) were evaluated for nutrient composition. The finger millet flour (FMF) was blended in various proportions (30 to 50%) in refined wheat flour and used for the preparation of noodles. Control consisted of RWF noodles. Sensory quality and nutrient composition of finger millet noodles was evaluated. The ...

  3. Thermal stability improvement of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations using non-uniform finger spacing

    International Nuclear Information System (INIS)

    Chen Liang; Zhang Wan-Rong; Jin Dong-Yue; Shen Pei; Xie Hong-Yun; Ding Chun-Bao; Xiao Ying; Sun Bo-Tao; Wang Ren-Qing

    2011-01-01

    A method of non-uniform finger spacing is proposed to enhance thermal stability of a multiple finger power SiGe heterojunction bipolar transistor under different power dissipations. Temperature distribution on the emitter fingers of a multi-finger SiGe heterojunction bipolar transistor is studied using a numerical electro-thermal model. The results show that the SiGe heterojunction bipolar transistor with non-uniform finger spacing has a small temperature difference between fingers compared with a traditional uniform finger spacing heterojunction bipolar transistor at the same power dissipation. What is most important is that the ability to improve temperature non-uniformity is not weakened as power dissipation increases. So the method of non-uniform finger spacing is very effective in enhancing the thermal stability and the power handing capability of power device. Experimental results verify our conclusions. (interdisciplinary physics and related areas of science and technology)

  4. Effect of the linkers between the zinc fingers in zinc finger protein 809 on gene silencing and nuclear localization

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Yu, E-mail: ichida-y@ncchd.go.jp; Utsunomiya, Yuko; Onodera, Masafumi

    2016-03-18

    Zinc finger protein 809 (ZFP809) belongs to the Kruppel-associated box-containing zinc finger protein (KRAB-ZFP) family and functions in repressing the expression of Moloney murine leukemia virus (MoMLV). ZFP809 binds to the primer-binding site (PBS)located downstream of the MoMLV-long terminal repeat (LTR) and induces epigenetic modifications at integration sites, such as repressive histone modifications and de novo DNA methylation. KRAB-ZFPs contain consensus TGEKP linkers between C2H2 zinc fingers. The phosphorylation of threonine residues within linkers leads to the inactivation of zinc finger binding to target sequences. ZFP809 also contains consensus linkers between zinc fingers. However, the function of ZFP809 linkers remains unknown. In the present study, we constructed ZFP809 proteins containing mutated linkers and examined their ability to silence transgene expression driven by MLV, binding ability to MLV PBS, and cellular localization. The results of the present study revealed that the linkers affected the ability of ZFP809 to silence transgene expression. Furthermore, this effect could be partly attributed to changes in the localization of ZFP809 proteins containing mutated linkers. Further characterization of ZFP809 linkers is required for understanding the functions and features of KRAB-ZFP-containing linkers. - Highlights: • ZFP809 has three consensus linkers between the zinc fingers. • Linkers are required for ZFP809 to silence transgene expression driven by MLV-LTR. • Linkers affect the precise nuclear localization of ZFP809.

  5. INTERACT

    DEFF Research Database (Denmark)

    Jochum, Elizabeth; Borggreen, Gunhild; Murphey, TD

    This paper considers the impact of visual art and performance on robotics and human-computer interaction and outlines a research project that combines puppetry and live performance with robotics. Kinesics—communication through movement—is the foundation of many theatre and performance traditions ...

  6. A novel zinc finger protein Zfp277 mediates transcriptional repression of the Ink4a/arf locus through polycomb repressive complex 1

    DEFF Research Database (Denmark)

    Negishi, Masamitsu; Saraya, Atsunori; Mochizuki, Shinobu

    2010-01-01

    . METHODOLOGY/PRINCIPAL FINDINGS: We examined the function of Zinc finger domain-containing protein 277 (Zfp277), a novel zinc finger protein that interacts with the PcG protein Bmi1. Zfp277 binds to the Ink4a/Arf locus in a Bmi1-independent manner and interacts with polycomb repressor complex (PRC) 1 through...... is essential for the recruitment of PRC1 to the Ink4a/Arf locus. Our findings also highlight dynamic regulation of both Zfp277 and PcG proteins by the oxidative stress pathways....

  7. Nailfold Capillaroscopy of Fingers and Toes - Variations of Normal.

    Science.gov (United States)

    Lambova, Sevdalina Nikolova; Muller-Ladner, Ulf

    2018-04-20

    Nailfold capillaroscopy is the only method for morphological assessment of nutritive capillaries. The literature data about capillaroscopic findings in healthy individuals are scarce. To evaluate and compare the capillaroscopic findings of fingers and toes in healthy subjects. 22 healthy individuals were included in the study. Capillaroscopic examination was performed with videocapillaroscope Videocap 3.0 (DS Medica). Exclusion criteria were as follows: history of vasospasm, presence of accompanying diseases, taking any medications, arterial hypertension in first degree relatives, overweight or obesity (body mass index > 25kg/m2) and presence of chronic arterial or venous insufficiency. Poor visibility of nailfold capillaries was found significantly more frequently in the toes (22.7%, 5/22) as compared with fingers (0/22). Slight irregularities in capillary distribution and orientation to their parallel axis were significantly more common in the toes (31.8%, 7/22) as compared with fingers (9%, 2/22), (p10%) was found significantly more often in the toes (12/22) as compared with fingers (6/22, χ2=6.769, p<0.05). Short capillary loops (length<100µm) were observed significantly more often in the toes (11/22 - toes, 1/22 - fingers, χ2=14.666, p<0.05). Capillaroscopic examination of the toes shows some differences as compared to those of the fingers such as greater number of cases with poor visibility and slight irregularities of distribution, greater number of shorter capillaries and increased tortuosity, which might be related to the thicker epidermis of the toes and increased capillary pressure due to gravity. The values of the major capillaroscopic parameters such as capillary diameters and capillary density in fingers and toes do not differ significantly. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Making fingers and words count in a cognitive robot

    Directory of Open Access Journals (Sweden)

    Vivian Milagros De La Cruz

    2014-02-01

    Full Text Available Evidence from developmental as well as neuroscientific studies suggest that finger counting activity plays an important role in the acquisition of numerical skills in children. It has been claimed that this skill helps in building motor-based representations of number that continue to influence number processing well into adulthood, facilitating the emergence of number concepts from sensorimotor experience through a bottom-up process. The act of counting also involves the acquisition and use of a verbal number system of which number words are the basic building blocks. Using a Cognitive Developmental Robotics paradigm we present results of a modeling experiment on whether finger counting and the association of number words (or tags to fingers, could serve to bootstrap the representation of number in a cognitive robot, enabling it to perform basic numerical operations such as addition. The cognitive architecture of the robot is based on artificial neural networks, which enable the robot to learn both sensorimotor skills (finger counting and linguistic skills (using number words. The results obtained in our experiments show that learning the number words in sequence along with finger configurations helps the fast building of the initial representation of number in the robot. Number knowledge, is instead, not as efficiently developed when number words are learned out of sequence without finger counting. Furthermore, the internal representations of the finger configurations themselves, developed by the robot as a result of the experiments, sustain the execution of basic arithmetic operations, something consistent with evidence coming from developmental research with children. The model and experiments demonstrate the importance of sensorimotor skill learning in robots for the acquisition of abstract knowledge such as numbers.

  9. Cylinder deactivation for valve trains with roller finger follower; Zylinderabschaltung fuer Ventiltriebe mit Rollenschlepphebeln

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Hermann; Loch, Adam; Widmann, Richard [Mahle International GmbH, Stuttgart (Germany). Zentrale Voraussentwicklung; Kreussen, Gerhard; Rebbert, Martin [FEV Motorentechnik GmbH, Aachen (Germany). Abt. Dynamik; Meehsen, Daniel [FEV Motorentechnik GmbH, Aachen (Germany). Abt. Mechanik Versuch

    2009-04-15

    Cylinder deactivation increases efficiency of gasoline engines without negative effects in terms of exhaust gas emissions or driving dynamics. In particular, the advantageous cost/benefit ratio and great affinity to technologies currently used in gasoline engines support cylinder deactivation as the right path in meeting future market demands. The design and function of cylinder deactivation for valve trains with roller finger follower will be explained and examined with regard to functional aspects, such as stiffness, mass, and kinematic behavior. Based on initial results, design and production characteristics of this new technology are evaluated and technical control interactions in engine applications are presented by Mahle. (orig.)

  10. The extent of variation in salinity tolerance of the minicore collection of finger millet (Eleusine coracana L. Gaertn.) germplasm.

    Science.gov (United States)

    Krishnamurthy, Lakshmanan; Upadhyaya, Hari Deo; Purushothaman, Ramamoorthy; Gowda, Cholenahalli Lakkegowda Laxmipathi; Kashiwagi, Junichi; Dwivedi, Sangam Lal; Singh, Sube; Vadez, Vincent

    2014-10-01

    Finger millet (Eleusine coracana L. Gaertn.) ranks third in production among the dry land cereals. It is widely cultivated in Africa and South Asia where soil salinization is a major production constraint. It is a potential crop for salt affected soils. To identify salt tolerant germplasm, the minicore finger millet germplasm (n=80) was screened for grain yield performance in a soil saturated with NaCl solution of 100 or 125mM. Genotype effect was significant for most traits, while salinity×genotype interaction was significant only in one year. Salinity delayed phenology, marginally reduced shoot biomass and grain yield. There was a large range of genotypic variation in grain yield under salinity and other traits. The yield loss was higher in accessions with prolific growth and yield potential was associated with saline yields. Based on saline yields, accessions were grouped in to four groups and the top tolerant group had 22 accessions with IE 4797 remaining at the top. Salinity had no adverse impact on grain yield of five accessions. Root anatomy in selected genotype of pearl and finger millet showed presence of porous cortex and well fortified endodermis in finger millet that can exclude Na(+) and enhance N absorption. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. ANALYSIS of Control Force Grasping for a Multifunctional Five Fingered Robot to Pick-up Various of Components

    Directory of Open Access Journals (Sweden)

    Widhiada W.

    2016-01-01

    Full Text Available Multi-fingered robot gripper has become popular in the major research topics as grasping an object in robotic systems. The author considers a matter of style-based control model for a multi-fingered robot hand grasping an object with a known geometric characteristics. This paper introduces design process and analysis of contact force the five fingered gripper suitable to handle several of objects. The author applied Simulink/SimMechanics, Support package Arduino and Inventor software packages to facilatate and integrated the design of contact force gripper systems. The advance of PID control is used to control dynamics motions of the five fingered gripper systems. The multifunction finger’s gripper is developed to handle the various components. Contact force between fingertips and object surface is computed using the Hooke law concept. The analysis of experiment result shows the optimum of contact forces are achieved to hold the object. The spring and damper algorithm is used to compute the interaction of force between fingertips and object surface.

  12. The Effect of Different Attentional Focus Instructions during Finger Movement Tasks in Healthy Subjects: An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Giacomo Rossettini

    2017-01-01

    Full Text Available External focus of attention (EFA and internal focus of attention (IFA represent commonly used strategies to instruct subjects during exercise. Several studies showed EFA to be more effective than IFA to improve motor performance and learning. To date the role of these strategies on motor performance during finger movement was less studied. The objective of the study was to investigate motor performance, patient’s preference induced by IFA and EFA, and the focus during control condition. Ten healthy right-handed participants performed a finger movement task in control, EFA, and IFA conditions (counterbalanced. Errors, patient’s preference, and type of attentional focus spontaneously adopted during the control condition were recorded. EFA determined less error (p<0.01 compared to control and IFA. Participants preferred EFA against IFA and control condition. In the control group 10% of subjects adopted a purely EFA, 70% of subjects adopted a purely IFA, and 20% of subjects adopted a mixture of the two foci. Our results confirm that EFA is more effective than IFA and control in finger movement task. Due its clinical relevance, the interaction between attention and finger movement should be further investigated.

  13. Diagnostic aspects of vibration-induced white finger.

    Science.gov (United States)

    Olsen, Niels

    2002-01-01

    Vibration-induced white finger (VWF) is a secondary type of Raynaud's phenomenon (RP) caused by exposure to hand-arm vibration. The present review concerns the cold-provoked attack of RP in vasospastic VWF. It concentrates on the most common clinical and laboratory methods used to diagnose RP in vibration-exposed subjects. Some physiological aspects of the attack of RP are mentioned to elucidate the diagnostic principles of the tests. Anamnestic diagnostics by medical interviews and questionnaires as well as cold-provocation tests with detection of finger colour, finger systolic blood pressure (FSP), recovery time of finger skin temperature and recovery time of normal nail colour after nail compression are mentioned. The discriminative capacity and the reproducibility of the tests are discussed. Cold-provocation tests with detection of finger colour or zero FSP during cooling are recommended to be used if an attack of RP has to be registered for diagnostic or medico-legal purposes in individual cases. An abnormal reduction in FSP during cooling makes a history of RP very probable and is a suitable laboratory test for groups of subjects. Both recovery tests may be useful screening tests in field studies of vibration-exposed subject groups.

  14. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    Energy Technology Data Exchange (ETDEWEB)

    Yasumoto, Kyoden; Fujino, Masayuki; Supriyadi (Kyoto Univ., Uji (Japan). Research Inst. for Food Science); Suzuki, Tetsuya; Hayashi, Toru

    1991-08-01

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 10{sup 8}/g. Turmeric finger which was irradiated by electron beam at 10 kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10 kGy and 20 kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers. (author).

  15. Finger Vein Recognition Based on Personalized Weight Maps

    Science.gov (United States)

    Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu

    2013-01-01

    Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition. PMID:24025556

  16. The biometric recognition on contactless multi-spectrum finger images

    Science.gov (United States)

    Kang, Wenxiong; Chen, Xiaopeng; Wu, Qiuxia

    2015-01-01

    This paper presents a novel multimodal biometric system based on contactless multi-spectrum finger images, which aims to deal with the limitations of unimodal biometrics. The chief merits of the system are the richness of the permissible texture and the ease of data access. We constructed a multi-spectrum instrument to simultaneously acquire three different types of biometrics from a finger: contactless fingerprint, finger vein, and knuckleprint. On the basis of the samples with these characteristics, a moderate database was built for the evaluation of our system. Considering the real-time requirements and the respective characteristics of the three biometrics, the block local binary patterns algorithm was used to extract features and match for the fingerprints and finger veins, while the Oriented FAST and Rotated BRIEF algorithm was applied for knuckleprints. Finally, score-level fusion was performed on the matching results from the aforementioned three types of biometrics. The experiments showed that our proposed multimodal biometric recognition system achieves an equal error rate of 0.109%, which is 88.9%, 94.6%, and 89.7% lower than the individual fingerprint, knuckleprint, and finger vein recognitions, respectively. Nevertheless, our proposed system also satisfies the real-time requirements of the applications.

  17. A Method for Recognizing State of Finger Flexure and Extension

    Science.gov (United States)

    Terado, Toshihiko; Fujiwara, Osamu

    In our country, the handicapped and the elderly people in bed increase rapidly. In the bedridden person’s daily life, there may be limitations in the physical movement and the means of mutual communication. For the support of their comfortable daily lives, therefore, the development of human interface equipment becomes an important task. The equipment of this kind is being already developed by means of laser beam, eye-tracking, breathing motion and myo-electric signals, while the attachment and handling are normally not so easy. In this study, paying attention to finger motion, we have developed human interface equipment easily attached to the body, which enables one to measure the finger flexure and extension for mutual communication. The state of finger flexure and extension is identified by a threshold level analysis from the 3D-locus data for the finger movement, which can be measured through the infrared rays from the LED markers attached to a glove with the previously developed prototype system. We then have confirmed from an experiment that nearly 100% recognition for the finger movement can be achieved.

  18. The genetic map of finger millet, Eleusine coracana.

    Science.gov (United States)

    Dida, Mathews M; Srinivasachary; Ramakrishnan, Sujatha; Bennetzen, Jeffrey L; Gale, Mike D; Devos, Katrien M

    2007-01-01

    Restriction fragment length polymorphism (RFLP), amplified fragment length polymorphism (AFLP), expressed-sequenced tag (EST), and simple sequence repeat (SSR) markers were used to generate a genetic map of the tetraploid finger millet (Eleusine coracana subsp. coracana) genome (2n = 4x = 36). Because levels of variation in finger millet are low, the map was generated in an inter-subspecific F(2) population from a cross between E. coracana subsp. coracana cv. Okhale-1 and its wild progenitor E. coracana subsp. africana acc. MD-20. Duplicated loci were used to identify homoeologous groups. Assignment of linkage groups to the A and B genome was done by comparing the hybridization patterns of probes in Okhale-1, MD-20, and Eleusine indica acc. MD-36. E. indica is the A genome donor to E. coracana. The maps span 721 cM on the A genome and 787 cM on the B genome and cover all 18 finger millet chromosomes, at least partially. To facilitate the use of marker-assisted selection in finger millet, a first set of 82 SSR markers was developed. The SSRs were identified in small-insert genomic libraries generated using methylation-sensitive restriction enzymes. Thirty-one of the SSRs were mapped. Application of the maps and markers in hybridization-based breeding programs will expedite the improvement of finger millet.

  19. Finger Vein Recognition Based on Personalized Weight Maps

    Directory of Open Access Journals (Sweden)

    Lu Yang

    2013-09-01

    Full Text Available Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs. The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition.

  20. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    International Nuclear Information System (INIS)

    Yasumoto, Kyoden; Fujino, Masayuki; Supriyadi; Suzuki, Tetsuya; Hayashi, Toru.

    1991-01-01

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 10 8 /g. Turmeric finger which was irradiated by electron beam at 10 kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10 kGy and 20 kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers. (author)

  1. Evaluation of electron beam irradiation for disinfection of turmeric fingers

    International Nuclear Information System (INIS)

    Yasumoto, K.; Fujino, M.; Supriyadi; Suzuki, T.; Hayashi, T.

    1991-01-01

    Turmeric finger as one of the most popular spices has been widely used for food manufacturing. However, it has also been a major cause of bacterial infestation of food materials especially in curry, ham and sausage manufacturing. In this study decontamination of bacteria in turmeric finger by electron beam irradiation was evaluated by comparing with several other decontamination methods: i.e., boiling, microwave irradiation, treatment by twin screw extruder and gamma-ray irradiation. By estimation of colony counting on nutrient agar plate, turmeric finger without any treatment gave total viable cell at 10 8 /g. Turmeric finger which was irradiated by electron beam at 10kGy dose dramatically reduced thermotolerant cell population below self restriction level (<1000/g), which has been required by food hygiene law. The same level of sterilization effect was obtained only by gamma-ray irradiation at 10kGy and 20kGy. On the other hand, although treatment through twin screw extruder slightly reduced bacterial numbers, neither boiling nor microwave irradiation gave sufficient decontamination effect on turmeric fingers

  2. Hybrid-Actuated Finger Prosthesis with Tactile Sensing

    Directory of Open Access Journals (Sweden)

    Cheng Yee Low

    2013-10-01

    Full Text Available Finger prostheses are devices developed to emulate the functionality of natural human fingers. On top of their aesthetic appearance in terms of shape, size and colour, such biomimetic devices require a high level of dexterity. They must be capable of gripping an object, and even manipulating it in the hand. This paper presents a biomimetic robotic finger actuated by a hybrid mechanism and integrated with a tactile sensor. The hybrid actuation mechanism comprises a DC micromotor and a Shape Memory Alloy (SMA wire. A customized test rig has been developed to measure the force and stroke produced by the SMA wire. In parallel with the actuator development, experimental investigations have been conducted on Quantum Tunnelling Composite (QTC and Pressure Conductive Rubber (PCR towards the development of a tactile sensor for the finger. The viability of using these materials for tactile sensing has been determined. Such a hybrid actuation approach aided with tactile sensing capability enables a finger design as an integral part of a prosthetic hand for applications up to the transradial amputation level.

  3. Genome-Wide Identification and Analysis of Genes Encoding PHD-Finger Protein in Tomato

    International Nuclear Information System (INIS)

    Hayat, S.; Cheng, Z.; Chen, X.

    2016-01-01

    The PHD-finger proteins are conserved in eukaryotic organisms and are involved in a variety of important functions in different biological processes in plants. However, the function of PHD fingers are poorly known in tomato (Solanum lycopersicum L.). In current study, we identified 45 putative genes coding Phd finger protein in tomato distributed on 11 chromosomes except for chromosome 8. Some of the genes encode other conserved key domains besides Phd-finger. Phylogenetic analysis of these 45 proteins resulted in seven clusters. Most Phd finger proteins were predicted to PML body location. These PHD-finger genes displayed differential expression either in various organs, at different development stages and under stresses in tomato. Our study provides the first systematic analysis of PHD-finger genes and proteins in tomato. This preliminary study provides a very useful reference information for Phd-finger proteins in tomato. They will be helpful for cloning and functional study of tomato PHD-finger genes. (author)

  4. Fingering in a channel and tripolar Loewner evolutions

    Science.gov (United States)

    Durán, Miguel A.; Vasconcelos, Giovani L.

    2011-11-01

    A class of Laplacian growth models in the channel geometry is studied using the formalism of tripolar Loewner evolutions, in which three points, namely, the channel corners and the point at infinity, are kept fixed. Initially, the problem of fingered growth, where growth takes place only at the tips of slitlike fingers, is revisited and a class of exact solutions of the corresponding Loewner equation is presented for the case of stationary driving functions. A model for interface growth is then formulated in terms of a generalized tripolar Loewner equation and several examples are presented. It is shown that the growing interface evolves into a steadily moving finger and that tip competition arises for nonsymmetric initial configurations with multiple tips.

  5. Finger Vein Recognition Based on a Personalized Best Bit Map

    Science.gov (United States)

    Yang, Gongping; Xi, Xiaoming; Yin, Yilong

    2012-01-01

    Finger vein patterns have recently been recognized as an effective biometric identifier. In this paper, we propose a finger vein recognition method based on a personalized best bit map (PBBM). Our method is rooted in a local binary pattern based method and then inclined to use the best bits only for matching. We first present the concept of PBBM and the generating algorithm. Then we propose the finger vein recognition framework, which consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PBBM achieves not only better performance, but also high robustness and reliability. In addition, PBBM can be used as a general framework for binary pattern based recognition. PMID:22438735

  6. Effect of transcranial magnetic stimulation on force of finger pinch

    Science.gov (United States)

    Odagaki, Masato; Fukuda, Hiroshi; Hiwaki, Osamu

    2009-04-01

    Transcranial magnetic stimulation (TMS) is used to explore many aspects of brain function, and to treat neurological disorders. Cortical motor neuronal activation by TMS over the primary motor cortex (M1) produces efferent signals that pass through the corticospinal tracts. Motor-evoked potentials (MEPs) are observed in muscles innervated by the stimulated motor cortex. TMS can cause a silent period (SP) following MEP in voluntary electromyography (EMG). The present study examined the effects of TMS eliciting MEP and SP on the force of pinching using two fingers. Subjects pinched a wooden block with the thumb and index finger. TMS was applied to M1 during the pinch task. EMG of first dorsal interosseous muscles and pinch forces were measured. Force output increased after the TMS, and then oscillated. The results indicated that the motor control system to keep isotonic forces of the muscles participated in the finger pinch was disrupted by the TMS.

  7. Compensating Pose Uncertainties through Appropriate Gripper Finger Cutouts

    DEFF Research Database (Denmark)

    Wolniakowski, Adam; Gams, Andrej; Kiforenko, Lilita

    2018-01-01

    The gripper finger design is a recurring problem in many robotic grasping platforms used in industry. The task of switching the gripper configuration to accommodate a new batch of objects typically requires engineering expertise and is a lengthy and costly iterative trial-and-error process. One...... in a sample industrial object grasping scenario for a finger that was designed using an automated simulation-based geometry optimization method (Wolniakowski et al., 2013, 2015). We test the developed gripper with a set of grasps subjected to structured perturbation in a simulation environment and in the real......-world setting. We provide a comparison of the data obtained by using both of these approaches. We argue that the strong correspondence observed in results validates the use of dynamic simulation for the gripper finger design and optimization....

  8. Finger vein recognition based on convolutional neural network

    Directory of Open Access Journals (Sweden)

    Meng Gesi

    2017-01-01

    Full Text Available Biometric Authentication Technology has been widely used in this information age. As one of the most important technology of authentication, finger vein recognition attracts our attention because of its high security, reliable accuracy and excellent performance. However, the current finger vein recognition system is difficult to be applied widely because its complicated image pre-processing and not representative feature vectors. To solve this problem, a finger vein recognition method based on the convolution neural network (CNN is proposed in the paper. The image samples are directly input into the CNN model to extract its feature vector so that we can make authentication by comparing the Euclidean distance between these vectors. Finally, the Deep Learning Framework Caffe is adopted to verify this method. The result shows that there are great improvements in both speed and accuracy rate compared to the previous research. And the model has nice robustness in illumination and rotation.

  9. Trigger finger presenting secondary to leiomyoma: a case report

    Directory of Open Access Journals (Sweden)

    Harb Ziad

    2009-05-01

    Full Text Available Abstract Introduction We present a previously undescribed entity: trigger finger secondary to a leiomyoma. This is the first time such a case has been reported and highlights the fact that common conditions can sometimes present secondary to rare diseases. Case presentation A 39-year-old Caucasian man presented with a fairly typical presentation of trigger finger. During surgical treatment, the lesion was excised and sent for histology, which showed tissue consistent with a leiomyoma. The patient made an uneventful recovery. Conclusion Trigger finger is a common condition that is usually easily diagnosed and managed. However, it is important to appreciate that uncommon conditions, such as leiomyoma, can present with what is sometimes considered trivial disease, and one should always consider the differential diagnoses even when faced with relatively benign conditions.

  10. The influence of intrinsic sympathomimetic activity and beta-1 receptor selectivity on the recovery of finger skin temperature after finger cooling in normotensive subjects.

    Science.gov (United States)

    Lenders, J W; Salemans, J; de Boo, T; Lemmens, W A; Thien, T; van't Laar, A

    1986-03-01

    A double-blind randomized study was designed to investigate differences in the recovery of finger skin temperature after finger cooling during dosing with placebo or one of four beta-blockers: propranolol, atenolol, pindolol, and acebutolol. In 11 normotensive nonsmoking subjects, finger skin temperature was measured with a thermocouple before and 20 minutes after immersion of one hand in a water bath at 16 degrees C. This finger cooling test caused no significant changes in systemic hemodynamics such as arterial blood pressure, heart rate, and forearm blood flow. The recovery of finger skin temperature during propranolol dosing was better than that during pindolol and atenolol dosing. There were no differences between the recoveries of skin temperature during pindolol, atenolol, and acebutolol dosing. Thus we could demonstrate no favorable effect of intrinsic sympathomimetic activity or beta 1-selectivity on the recovery of finger skin temperature after finger cooling.

  11. Viscous fingering effects in solvent displacement of heavy oil

    Energy Technology Data Exchange (ETDEWEB)

    Cuthiell, D. [Suncor Energy, Fort McMurray, AB (Canada); Kissel, G.; Jackson, C.; Frauenfeld, T.W.J.; Fisher, D. [Alberta Research Council, Devon, AB (Canada); Rispler, K. [Saskatchewan Research Council, Saskatoon, SK (Canada)

    2004-07-01

    Vapour Extraction (VAPEX) is a solvent-based process that is analogous to steam-assisted gravity drainage (SAGD) for the recovery of heavy oil. A cyclic solvent process is preferred for thin reservoirs, particularly primary-depleted reservoirs. In a cyclic steam stimulation process, a solvent is injected into the reservoir for a period of time before oil is produced from the well. Viscous fingering is a phenomena that characterizes several solvent-based processes for the recovery of heavy oil. A combined experimental and simulation study was conducted to characterize viscous fingering under heavy oil recovery conditions (high ratio of oil to solvent viscosity). Four experiments were conducted in heavy oil-saturated sand packs. Three involved injection of a miscible, liquid solvent at the bottom of the sand pack. The heavy oil in these experiments was displaced upwardly. The fourth experiment involved top-down injection of a gaseous solvent. The miscible liquid displacement was dominated by one solvent finger which broke through to a producing well at the other end of the sand pack. Breakthrough times were similar to that at lower viscosity. The fourth experiment showed fingering along with features of a gravity-driven VAPEX process. Key features of the experiment and realistic fingering patterns were numerically simulated using a commercial reservoir simulator. It was emphasized that accurate modelling of dispersion is necessary in matching the observed phenomena. The simulations should include the capillary effects because of their significance for gaseous fingering and the VAPEX processes. 17 refs., 2 tabs., 20 figs.

  12. Magnetic resonance imaging and radiographic findings of seal finger

    International Nuclear Information System (INIS)

    Marjelund, S.; Tikkakoski, T.; Isokangas, M.; Raeisaenen, S.

    2006-01-01

    Purpose: To describe the magnetic resonance imaging (MRI) and radiographic findings of five patients with seal finger. Material and Methods: The MR images and radiographs of five patients with seal finger were retrospectively evaluated. MRI was performed on four patients in the subacute phase, and follow-up imaging was done on one of them at 5 months. One patient had MRI only at a later stage 5 years after onset. Radiographs were taken three times in the subacute phase and once at a later stage. One patient had had seal finger in another finger previously. Results: Short-tau inversion-recovery (STIR) sequence showed extensive subcutaneous soft tissue edema in all four patients in the subacute phase and tenosynovitis of the flexion tendons in two cases. Three patients had edema in 2-3 phalanges, and effusion in the distal interphalangeal (DIP) joint was seen in one case. At the later stage, no signal pathology in soft tissues or bones was seen in STIR images. In the subacute phase, radiographs showed digital soft-tissue swelling in three patients, and one patient had a narrowed DIP joint, periarticular osteoporosis, and a periosteal reaction. At the later stage, flexion contracture of the finger was seen. Conclusion: In addition to soft-tissue infection, seal finger causes bone marrow edema, tenosynovitis, and effusion in the interphalangeal joints visible as increased signal intensity in STIR images. Radiographs reveal periarticular osteoporosis with loss of cartilage in the subacute phase and flexion contracture at the later stage. MRI (STIR) allows more precise delineation of the inflammatory process compared to radiography

  13. Magnetic resonance imaging and radiographic findings of seal finger

    Energy Technology Data Exchange (ETDEWEB)

    Marjelund, S.; Tikkakoski, T.; Isokangas, M.; Raeisaenen, S. [Oulu Univ. Hospital (Finland). Dept. of Radiology

    2006-12-15

    Purpose: To describe the magnetic resonance imaging (MRI) and radiographic findings of five patients with seal finger. Material and Methods: The MR images and radiographs of five patients with seal finger were retrospectively evaluated. MRI was performed on four patients in the subacute phase, and follow-up imaging was done on one of them at 5 months. One patient had MRI only at a later stage 5 years after onset. Radiographs were taken three times in the subacute phase and once at a later stage. One patient had had seal finger in another finger previously. Results: Short-tau inversion-recovery (STIR) sequence showed extensive subcutaneous soft tissue edema in all four patients in the subacute phase and tenosynovitis of the flexion tendons in two cases. Three patients had edema in 2-3 phalanges, and effusion in the distal interphalangeal (DIP) joint was seen in one case. At the later stage, no signal pathology in soft tissues or bones was seen in STIR images. In the subacute phase, radiographs showed digital soft-tissue swelling in three patients, and one patient had a narrowed DIP joint, periarticular osteoporosis, and a periosteal reaction. At the later stage, flexion contracture of the finger was seen. Conclusion: In addition to soft-tissue infection, seal finger causes bone marrow edema, tenosynovitis, and effusion in the interphalangeal joints visible as increased signal intensity in STIR images. Radiographs reveal periarticular osteoporosis with loss of cartilage in the subacute phase and flexion contracture at the later stage. MRI (STIR) allows more precise delineation of the inflammatory process compared to radiography.

  14. Pattern formation of frictional fingers in a gravitational potential

    Science.gov (United States)

    Eriksen, Jon Alm; Toussaint, Renaud; Mâløy, Knut Jørgen; Flekkøy, Eirik; Galland, Olivier; Sandnes, Bjørnar

    2018-01-01

    Aligned finger structures, with a characteristic width, emerge during the slow drainage of a liquid-granular mixture in a tilted Hele-Shaw cell. A transition from vertical to horizontal alignment of the finger structures is observed as the tilting angle and the granular density are varied. An analytical model is presented, demonstrating that the alignment properties are the result of the competition between fluctuating granular stresses and the hydrostatic pressure. The dynamics is reproduced in simulations. We also show how the system explains patterns observed in nature, created during the early stages of a dike formation.

  15. Finger Vein Recognition Using Local Line Binary Pattern

    Directory of Open Access Journals (Sweden)

    Bakhtiar Affendi Rosdi

    2011-11-01

    Full Text Available In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP.

  16. Finger vein recognition using local line binary pattern.

    Science.gov (United States)

    Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin

    2011-01-01

    In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP).

  17. Trace element finger printing of emeralds by PIXE and PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; Palmer, G.R.; MacArthur, J.D.

    1990-01-01

    The concentrations of 18 major- and minor-elements in 12 Emeralds from different mines and two synthetic ones are measured with proton induced X-ray emission (PIXE) and γ-ray emission (PIGE). The concentration and distribution of 18 elements are used to establish the characteristic finger print pattern of each Emerald. With the help of cluster analysis of SYSTAT statistical package for IBMPC, these finger prints are analysed, from which a quantitative description of the dissimilarities between Emeralds can be given

  18. Finger Vein Recognition Using Local Line Binary Pattern

    Science.gov (United States)

    Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin

    2011-01-01

    In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP). PMID:22247670

  19. Investigating the DNA-binding ability of GATA-1-N-terminal zinc finger

    International Nuclear Information System (INIS)

    Wong, R.; Newton, A.; Crossley, M.; Mackay, J.

    2001-01-01

    Erythroid transcription factor GATA-1 interacts with both DNA and other proteins through its zinc finger domains (ZnFs). While it has been known for me time that the C-terminal ZnF binds DNA at GATA sites, only recently has it been observed that the N-terminal finger (NF) is capable of interacting with GATC sites. Further, a number of naturally occurring mutations in NF (V205M, G208S, R216Q, D218G) that lead to anaemia and thrombocytopenia have been identified. We are interested in characterising the NF-DNA interaction and determining the effects of mutation upon this interaction. Using nuclear magnetic resonance (NMR) spectroscopy, we have observed an interaction between recombinant NF and a 16-mer DNA duplex containing a core GATC sequence. This result forms the basis from which residues in NF involved in DNA binding can be identified, and work is being carried out to improve the quality of the NMR data with the aim of determining the solution structure of the NF-DNA complex. The DNA-binding affinity of both wild-type and mutant NFs mentioned above is also being investigated using isothermal titration calorimetry. These data suggest that the strength of the interaction between NF and the 16-mer DNA duplex is in the sub-micromolar range, and comparisons between the DNA-binding affinities of the NF mutants are being made. Together, these studies will help us to understand how GATA-1 acts as a transcriptional regulator and how mutations in NF domain of GATA-1 may lead to blood disorders

  20. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    Science.gov (United States)

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  1. Presenting using Two-Handed Interaction in Open Space

    NARCIS (Netherlands)

    Vlaming, Luc; Smit, Jasper; Isenberg, Tobias

    2008-01-01

    Based on recent demonstrations of low-cost, infrared-based point tracking, we explore two-handed, surface-less interaction for presentation. On both hands, thumb and index finger are equipped with retro-reflective markers which are tracked by a Wiimote. We contribute a robust finger pairing and

  2. Touching lips and hearing fingers: effector-specific congruency between tactile and auditory stimulation modulates N1 amplitude and alpha desynchronization.

    Science.gov (United States)

    Shen, Guannan; Meltzoff, Andrew N; Marshall, Peter J

    2018-01-01

    Understanding the interactions between audition and sensorimotor processes is of theoretical importance, particularly in relation to speech processing. Although one current focus in this area is on interactions between auditory perception and the motor system, there has been less research on connections between the auditory and somatosensory modalities. The current study takes a novel approach to this omission by examining specific auditory-tactile interactions in the context of speech and non-speech sound production. Electroencephalography was used to examine brain responses when participants were presented with speech syllables (a bilabial sound /pa/ and a non-labial sound /ka/) or finger-snapping sounds that were simultaneously paired with tactile stimulation of either the lower lip or the right middle finger. Analyses focused on the sensory-evoked N1 in the event-related potential and the extent of alpha band desynchronization elicited by the stimuli. N1 amplitude over fronto-central sites was significantly enhanced when the bilabial /pa/ sound was paired with tactile lip stimulation and when the finger-snapping sound was paired with tactile stimulation of the finger. Post-stimulus alpha desynchronization at central sites was also enhanced when the /pa/ sound was accompanied by tactile stimulation of the lip. These novel findings indicate that neural aspects of somatosensory-auditory interactions are influenced by the congruency between the location of the bodily touch and the bodily origin of a perceived sound.

  3. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex.

    Science.gov (United States)

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-07-14

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  4. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex

    Directory of Open Access Journals (Sweden)

    Shan Juan Xie

    2015-07-01

    Full Text Available Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc. vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs. In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV normalization method using guided filter based single scale retinex (GFSSR is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  5. Zinc finger protein 521 overexpression increased transcript levels of ...

    Indian Academy of Sciences (India)

    2016-02-12

    Feb 12, 2016 ... Zinc finger protein 521 is highly expressed in brain, neural stem cells and early progenitors of the human .... Membranes were blocked for 1 h with 10% skim milk and ..... fat-like development of white fat and thermogenesis.

  6. Analyses results of the EHF FW Panel with welded fingers

    International Nuclear Information System (INIS)

    Sviridenko, M.N.; Leshukov, A.Yu.; Razmerov, A.V.; Tomilov, S.N.; Danilov, I.V.; Strebkov, Yu.S.; Mazul, I.V.; Labusov, A.; Gervash, A.A.; Belov, A.V.; Semichev, D.

    2014-01-01

    Highlights: • The design of FW panel with welded fingers has been developed. • The FW panel with welded fingers has been analyzed. • The pressure drop in FW panel coolant path do not exceed allowable one. • The mass flow rate distribution between finger pairs are on acceptable level. • Temperatures in FW components do not exceed allowable one. - Abstract: According to Procurement Arrangement (PA) Russian Federation will procure 40% of enhanced heat flux first wall (FW) panels. The signing of PA is scheduled on November 2013. In framework of PA preparation the RF specialists perform EHF FW design optimization in order to provide the ability to operation of EHF FW panel under ITER conditions. This article contains the design description of EHF FW 14 developed by RF and following analysis have been performed: • Hydraulic analysis; • Transient thermal analysis; • Structural analysis. Analyses results show that new design of FW panel with two straight welds for finger fixation on FW beam developed by RF specialists can be used as a reference design for ITER blanket EHF FW panel loaded by 5 MW/m 2 peak heat flux

  7. Rhythmic finger tapping reveals cerebellar dysfunction in essential tremor

    NARCIS (Netherlands)

    Buijink, A. W. G.; Broersma, M.; van der Stouwe, A. M. M.; van Wingen, G. A.; Groot, P. F. C.; Speelman, J. D.; Maurits, N. M.; van Rootselaar, A. F.

    Introduction: Cerebellar circuits are hypothesized to play a central role in the pathogenesis of essential tremor. Rhythmic finger tapping is known to strongly engage the cerebellar motor circuitry. We characterize cerebellar and, more specifically, dentate nucleus function, and neural correlates of

  8. Rhythmic finger tapping reveals cerebellar dysfunction in essential tremor

    NARCIS (Netherlands)

    Buijink, A. W. G.; Broersma, M.; van der Stouwe, A. M. M.; van Wingen, G. A.; Groot, P. F. C.; Speelman, J. D.; Maurits, N. M.; van Rootselaar, A. F.

    2015-01-01

    Cerebellar circuits are hypothesized to play a central role in the pathogenesis of essential tremor. Rhythmic finger tapping is known to strongly engage the cerebellar motor circuitry. We characterize cerebellar and, more specifically, dentate nucleus function, and neural correlates of cerebellar

  9. Amniogenesis in Schreiber's long-fingered bat Miniopterus ...

    African Journals Online (AJOL)

    Schreiber's long-fingered bat, Miniopterus schreibersii natalensis is seasonally monoestrous, carrying a single foetus in the right uterine horn. Implantation is superficial, the amnion being a pleuramnion. Lateral folds, originating from the ends of the caudal and cephalic folds, are the main contributors in the formation of the ...

  10. Movement Kinematics of the Braille-Reading Finger

    Science.gov (United States)

    Hughes, Barry

    2011-01-01

    A new means of measuring the movement properties of the braille-reading finger is described and exemplified in an experiment in which experienced readers of braille encountered sentences comprised of keywords in which word and orthographic frequencies were manipulated. These new data are considered in theoretical and practical terms. (Contains 2…

  11. Tensile Strength of Finger Joints at Elevated Temperatures

    DEFF Research Database (Denmark)

    Nielsen, Peter C.; Olesen, Frits Bolonius

    A series of test s aimed a t establishing the effect of temperature upon the tensile strength parallel-to-grain of finger jointed laminae for glulam has been conducted in the Fire Research Laboratory at Aalborg University Centre. The objective of this report is to present the background...

  12. Determining stress during finger propagation in 2D foams

    NARCIS (Netherlands)

    Staicu, A.D.; van Gelder, Bas; Hilgenfeldt, Sascha; Gutkowski, Witold; Kowalewski, Tomasz A.

    2004-01-01

    We investigate the formation of fingering patterns in a radial Hele-Shaw cell filled with quasi-two-dimensional polydisperse foam of very small liquid content. Air is used as the low-viscosity driving fluid. Using high speed imaging (up to 2000fps), we directly observe the topological rearrangements

  13. Perceptual grouping affects haptic enumeration over the fingers

    NARCIS (Netherlands)

    Overvliet, K.E.; Plaisier, M.A.

    2016-01-01

    Spatial arrangement is known to influence enumeration times in vision. In haptic enumeration, it has been shown that dividing the total number of items over the two hands can speed up enumeration. Here we investigated how spatial arrangement of items and non-items presented to the individual fingers

  14. Spontaneous eye blinks are entrained by finger tapping.

    Science.gov (United States)

    Cong, D-K; Sharikadze, M; Staude, G; Deubel, H; Wolf, W

    2010-02-01

    We studied the mutual cross-talk between spontaneous eye blinks and continuous, self-paced unimanual and bimanual tapping. Both types of motor activities were analyzed with regard to their time-structure in synchronization-continuation tapping tasks which involved different task instructions, namely "standard" finger tapping (Experiment 1), "strong" tapping (Experiment 2) requiring more forceful finger movements, and "impulse-like" tapping (Experiment 3) where upward-downward finger movements had to be very fast. In a further control condition (Experiment 4), tapping was omitted altogether. The results revealed a prominent entrainment of spontaneous blink behavior by the manual tapping, with bimanual tapping being more effective than unimanual tapping, and with the "strong" and "impulse-like" tapping showing the largest effects on blink timing. Conversely, we found no significant effects of the tapping on the timing of the eye blinks across all experiments. The findings suggest a functional overlap of the motor control structures responsible for voluntary, rhythmic finger movements and eye blinking behavior.

  15. Science Fair Report: Flight of the Split-Fingered Fastball.

    Science.gov (United States)

    Mitchell, Richard J.

    1991-01-01

    Reports on the results of an eighth grade student's experiments, conducted with a moving car, concerning the aerodynamics of a baseball in flight. Describes the peculiar diving ability of the split-fingered fastball, as well as the dancing and weaving effect of the knuckleball. (JJK)

  16. Reference values for the nickel concentration in human finger nails

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Peters, K; Menné, T

    1991-01-01

    A reference value for the nickel concentration in finger nails from people who are not occupationally exposed to nickel was determined on the basis of nail samples from 95 healthy individuals. The mean +/- standard deviation was 1.19 +/- 1.61 mg/kg and the median was 0.49 mg/kg (range 0.042-7.50 mg...

  17. Radiographically ossified ganglion cyst of finger in a swimmer

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, J.; Anavim, A. [Department of Radiological Sciences, University of California, Orange (United States); Lin, F. [Department of Pathology, University of California, Irvine Medical Center, Orange (Canada)

    1998-12-01

    Ganglion cysts are fibrous-walled cystic lesions closely associated with joint or tendon sheaths and contain gelatinous mucinous fluid. The radiographic appearance is usually normal. Calcification or ossification in these cysts is extremely unusual. We report on an unusual appearing ganglion cyst of the little finger in a swimmer with ossification resembling myositis ossificans. (orig.) With 3 figs., 8 refs.

  18. Singing Greeting Card Beeper as a Finger Pulse Sensor

    Science.gov (United States)

    Belusic, Gregor; Zupancic, Gregor

    2010-01-01

    We constructed a robust and low-priced finger pulse sensor from a singing greeting card beeper. The beeper outputs the plethysmographic signal, which is indistinguishable from that of commercial grade sensors. The sensor can be used in school for a number of experiments in human cardiovascular physiology.

  19. Viscous and gravitational fingering in multiphase compositional and compressible flow

    Science.gov (United States)

    Moortgat, Joachim

    2016-03-01

    Viscous and gravitational fingering refer to flow instabilities in porous media that are triggered by adverse mobility or density ratios, respectively. These instabilities have been studied extensively in the past for (1) single-phase flow (e.g., contaminant transport in groundwater, first-contact-miscible displacement of oil by gas in hydrocarbon production), and (2) multi-phase immiscible and incompressible flow (e.g., water-alternating-gas (WAG) injection in oil reservoirs). Fingering in multiphase compositional and compressible flow has received much less attention, perhaps due to its high computational complexity. However, many important subsurface processes involve multiple phases that exchange species. Examples are carbon sequestration in saline aquifers and enhanced oil recovery (EOR) by gas or WAG injection below the minimum miscibility pressure. In multiphase flow, relative permeabilities affect the mobility contrast for a given viscosity ratio. Phase behavior can also change local fluid properties, which can either enhance or mitigate viscous and gravitational instabilities. This work presents a detailed study of fingering behavior in compositional multiphase flow in two and three dimensions and considers the effects of (1) Fickian diffusion, (2) mechanical dispersion, (3) flow rates, (4) domain size and geometry, (5) formation heterogeneities, (6) gravity, and (7) relative permeabilities. Results show that fingering in compositional multiphase flow is profoundly different from miscible conditions and upscaling techniques used for the latter case are unlikely to be generalizable to the former.

  20. Compensating Pose Uncertainties Through Appropriate Gripper Finger Cutouts

    DEFF Research Database (Denmark)

    Wolniakowski, Adam; Gams, Andrej; Kiforenko, Lilita

    2018-01-01

    The gripper finger design is a recurring problem in many robotic grasping platforms used in industry. The task of switching the gripper configuration to accommodate for a new batch of objects typically requires engineering expertise, and is a lengthy and costly iterative trial-and-error process. ...

  1. association between finger clubbing and chronic lung disease in hiv

    African Journals Online (AJOL)

    2013-11-11

    Nov 11, 2013 ... Background: Finger clubbing in HIV infected children is associated with pulmonary diseases. ... is easy and quick to detect without sophisticated equipment and very ... interstitial pneumonia, bronchiectasis, interstitial pneumonitis and .... P value. Chest x-ray report. Abnormal. 90 (75.0). 54 (90.0). 36 (60.0).

  2. Cold-Blooded Attention: Finger Temperature Predicts Attentional Performance.

    Science.gov (United States)

    Vergara, Rodrigo C; Moënne-Loccoz, Cristóbal; Maldonado, Pedro E

    2017-01-01

    Thermal stress has been shown to increase the chances of unsafe behavior during industrial and driving performances due to reductions in mental and attentional resources. Nonetheless, establishing appropriate safety standards regarding environmental temperature has been a major problem, as modulations are also be affected by the task type, complexity, workload, duration, and previous experience with the task. To bypass this attentional and thermoregulatory problem, we focused on the body rather than environmental temperature. Specifically, we measured tympanic, forehead, finger and environmental temperatures accompanied by a battery of attentional tasks. We considered a 10 min baseline period wherein subjects were instructed to sit and relax, followed by three attentional tasks: a continuous performance task (CPT), a flanker task (FT) and a counting task (CT). Using multiple linear regression models, we evaluated which variable(s) were the best predictors of performance. The results showed a decrement in finger temperature due to instruction and task engagement that was absent when the subject was instructed to relax. No changes were observed in tympanic or forehead temperatures, while the environmental temperature remained almost constant for each subject. Specifically, the magnitude of the change in finger temperature was the best predictor of performance in all three attentional tasks. The results presented here suggest that finger temperature can be used as a predictor of alertness, as it predicted performance in attentional tasks better than environmental temperature. These findings strongly support that peripheral temperature can be used as a tool to prevent unsafe behaviors and accidents.

  3. Cold-Blooded Attention: Finger Temperature Predicts Attentional Performance

    Directory of Open Access Journals (Sweden)

    Rodrigo C. Vergara

    2017-09-01

    Full Text Available Thermal stress has been shown to increase the chances of unsafe behavior during industrial and driving performances due to reductions in mental and attentional resources. Nonetheless, establishing appropriate safety standards regarding environmental temperature has been a major problem, as modulations are also be affected by the task type, complexity, workload, duration, and previous experience with the task. To bypass this attentional and thermoregulatory problem, we focused on the body rather than environmental temperature. Specifically, we measured tympanic, forehead, finger and environmental temperatures accompanied by a battery of attentional tasks. We considered a 10 min baseline period wherein subjects were instructed to sit and relax, followed by three attentional tasks: a continuous performance task (CPT, a flanker task (FT and a counting task (CT. Using multiple linear regression models, we evaluated which variable(s were the best predictors of performance. The results showed a decrement in finger temperature due to instruction and task engagement that was absent when the subject was instructed to relax. No changes were observed in tympanic or forehead temperatures, while the environmental temperature remained almost constant for each subject. Specifically, the magnitude of the change in finger temperature was the best predictor of performance in all three attentional tasks. The results presented here suggest that finger temperature can be used as a predictor of alertness, as it predicted performance in attentional tasks better than environmental temperature. These findings strongly support that peripheral temperature can be used as a tool to prevent unsafe behaviors and accidents.

  4. Optimal Finger Search Trees in the Pointer Machine

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Lagogiannis, George; Makris, Christos

    2003-01-01

    We develop a new finger search tree with worst-case constant update time in the Pointer Machine (PM) model of computation. This was a major problem in the field of Data Structures and was tantalizingly open for over twenty years while many attempts by researchers were made to solve it. The result...

  5. Variations in the nerves of the thumb and index finger.

    Science.gov (United States)

    Wallace, W A; Coupland, R E

    1975-11-01

    The digital nerves to the thumb and index finger have been studied by dissecting twenty-five embalmed upper limbs. The palmar digital nerves to the thumb were constant in position and course, with a short lateral cutaneous branch from the radial palmar digital nerve in 30 per cent of cases. The palmar digital nerves to the index finger had a variable pattern, the commonest arrangement, well described in Gray's Anatomy, occurring in 74 per cent of cases. The variations and their frequency are described. By examining histological cross-sections of the index finger it was found that of about 5,000 endoneurial tubes entering the finger, 60 per cent passed beyond the distal digital crease to supply the pulp and nail bed. The depth of the palmar digital nerves was about 3 millimetres, but less at the digital creases, and their diameter lay between 1 and 1.5 millimetres as far as the distal digital crease. Clinical applications of the findings are discussed.

  6. Gold Finger: Metal Jewellery as a Disease Modifying Antirheumatic Therapy!

    Directory of Open Access Journals (Sweden)

    T. Hlaing

    2009-01-01

    Full Text Available Polyarticular psoriatic arthritis is a chronic, progressive and disabling auto-immune disease often affecting the small joints of the hands in a symmetrical fashion. The disease can progress rapidly causing joint swelling and damaging cartilage and bone around the joints resulting in severe deformities. We report a very unusual case of a 49-year-old woman who presented with polyarticular psoriatic arthritis affecting all proximal interphalangeal (PIP joints of both hands except the left ring finger PIP joint. On clinical examination there was no evidence of arthritis in the left ring finger PIP joint. We confirmed the paucity of joint damage in the PIP joint of the left ring finger using more modern imaging modalities such as musculoskeletal ultrasound and MRI scan of the small joints of the hands. All other PIP joints in both hands demonstrated advanced degrees of joint damage secondary to chronic psoriatic inflammatory arthritis. We postulated that wearing a gold wedding ring has helped protecting the PIP joint of the left ring finger from the damaging effect of inflammatory arthritis. The possible mechanisms by which metal jewellery (gold ring confer protection to adjacent joints was discussed.

  7. Systematic classification of the His-Me finger superfamily.

    Science.gov (United States)

    Jablonska, Jagoda; Matelska, Dorota; Steczkiewicz, Kamil; Ginalski, Krzysztof

    2017-11-16

    The His-Me finger endonucleases, also known as HNH or ββα-metal endonucleases, form a large and diverse protein superfamily. The His-Me finger domain can be found in proteins that play an essential role in cells, including genome maintenance, intron homing, host defense and target offense. Its overall structural compactness and non-specificity make it a perfectly-tailored pathogenic module that participates on both sides of inter- and intra-organismal competition. An extremely low sequence similarity across the superfamily makes it difficult to identify and classify new His-Me fingers. Using state-of-the-art distant homology detection methods, we provide an updated and systematic classification of His-Me finger proteins. In this work, we identified over 100 000 proteins and clustered them into 38 groups, of which three groups are new and cannot be found in any existing public domain database of protein families. Based on an analysis of sequences, structures, domain architectures, and genomic contexts, we provide a careful functional annotation of the poorly characterized members of this superfamily. Our results may inspire further experimental investigations that should address the predicted activity and clarify the potential substrates, to provide more detailed insights into the fundamental biological roles of these proteins. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. Finger functionality and joystick design for complex hand control

    NARCIS (Netherlands)

    Grinten, M.P. van der; Krause, F.

    2006-01-01

    Joysticks and similar multi-directional controls are increasingly applied in machines, instruments and consumer goods. Operational complexity rises through miniaturization and additional control functions on the joystick. With this the effort for the finger, hand and arm, and for the perceptive and

  9. Moving Fingers under a Stick: A Laboratory Activity

    Science.gov (United States)

    Massalha, Taha; Lanir, Yuval; Gluck, Paul

    2011-01-01

    We consider a demonstration in which pupils alternately slide and stop their fingers under a long horizontal rod which they support. The changeover is described in terms of the relevant kinetic and static friction. We present a model calculation, performed on a spreadsheet, which clarifies the process and describes graphically the stepwise…

  10. Osseointegrated silicone finger prosthesis using dental implants: a renovated technique.

    Science.gov (United States)

    Vinnakota, Dileep Nag; Sankar, V Vijay; Chirumamilla, Naveen; Reddy, V Vamsikrishna

    2014-11-01

    In clinical practice, we come across patients with traumatically amputated or congenitally missing partial or complete fingers that can be restored using microsurgical replantation or transplantation procedures. However, in some cases this might not be possible due to systemic or local factors and the lost or missing part has to be replaced prosthetically to offer psychological and functional wellbeing. These prostheses can be constructed with various materials like acrylics or silicone retained with the help of auxiliary aids. However, these prostheses cause some hindrance in performing functions like writing, typing, etc. The aim of the present trial was to ameliorate the existing design of implant supported finger prosthesis. Distal phalange of middle finger replaced with implant supported silicone finger prosthesis is modified by utilizing a metal framework to support silicone material to improve rigidity while working. We could achieve a good function, esthetics and tactile sensibility with this modified design. Whenever, feasible this design can improve the performance and patients feel a deep sense of satisfaction and improved self-esteem with this modified prosthesis.

  11. The potential of young, green finger-jointed Eucalyptus grandis ...

    African Journals Online (AJOL)

    Drying will occur naturally while the lumber is fixed within the roof truss structure. The objectives of this study were (1) to investigate the strength and stiffness variation of the finger-jointed E. grandis product in both the green and dry state for different age and dimension lumber, (2) to investigate the variation in density, warp ...

  12. Prevalence of Finger Millet Diseases in Kaberamaido Subcounty ...

    African Journals Online (AJOL)

    world, the most important disease of finger mil- let is blast caused by the fungus Pyricularia grisea (Cook) Sacc (Adipala, 1980; Emechebe,. 1975i MCrae, 1922). Tar spot, caused by. Phyllachora eleusines P. Hen, is common on fin- ger millet approaching maturity especially in cooler and wetter areas of Uganda (Hen, 1970).

  13. The Promyelocytic Leukemia Zinc Finger Protein: Two Decades of Molecular Oncology

    International Nuclear Information System (INIS)

    Suliman, Bandar Ali; Xu, Dakang; Williams, Bryan Raymond George

    2012-01-01

    The promyelocytic leukemia zinc finger (PLZF) protein, also known as Zbtb16 or Zfp145, was first identified in a patient with acute promyelocytic leukemia, where a reciprocal chromosomal translocation t(11;17)(q23;q21) resulted in a fusion with the RARA gene encoding retinoic acid receptor alpha. The wild-type Zbtb16 gene encodes a transcription factor that belongs to the POK (POZ and Krüppel) family of transcriptional repressors. In addition to nine Krüppel-type sequence-specific zinc fingers, which make it a member of the Krüppel-like zinc finger protein family, the PLZF protein contains an N-terminal BTB/POZ domain and RD2 domain. PLZF has been shown to be involved in major developmental and biological processes, such as spermatogenesis, hind limb formation, hematopoiesis, and immune regulation. PLZF is localized mainly in the nucleus where it exerts its transcriptional repression function, and many post-translational modifications affect this ability and also have an impact on its cytoplasmic/nuclear dissociation. PLZF achieves its transcriptional regulation by binding to many secondary molecules to form large multi-protein complexes that bind to the regulatory elements in the promoter region of the target genes. These complexes are also capable of physically interacting with its target proteins. Recently, PLZF has become implicated in carcinogenesis as a tumor suppressor gene, since it regulates the cell cycle and apoptosis in many cell types. This review will examine the major advances in our knowledge of PLZF biological activities that augment its value as a therapeutic target, particularly in cancer and immunological diseases.

  14. Advanced analysis of finger-tapping performance: a preliminary study.

    Science.gov (United States)

    Barut, Cağatay; Kızıltan, Erhan; Gelir, Ethem; Köktürk, Fürüzan

    2013-06-01

    The finger-tapping test is a commonly employed quantitative assessment tool used to measure motor performance in the upper extremities. This task is a complex motion that is affected by external stimuli, mood and health status. The complexity of this task is difficult to explain with a single average intertap-interval value (time difference between successive tappings) which only provides general information and neglects the temporal effects of the aforementioned factors. This study evaluated the time course of average intertap-interval values and the patterns of variation in both the right and left hands of right-handed subjects using a computer-based finger-tapping system. Cross sectional study. Thirty eight male individuals aged between 20 and 28 years (Mean±SD = 22.24±1.65) participated in the study. Participants were asked to perform single-finger-tapping test for 10 seconds of test period. Only the results of right-handed (RH) 35 participants were considered in this study. The test records the time of tapping and saves data as the time difference between successive tappings for further analysis. The average number of tappings and the temporal fluctuation patterns of the intertap-intervals were calculated and compared. The variations in the intertap-interval were evaluated with the best curve fit method. An average tapping speed or tapping rate can reliably be defined for a single-finger tapping test by analysing the graphically presented data of the number of tappings within the test period. However, a different presentation of the same data, namely the intertap-interval values, shows temporal variation as the number of tapping increases. Curve fitting applications indicate that the variation has a biphasic nature. The measures obtained in this study reflect the complex nature of the finger-tapping task and are suggested to provide reliable information regarding hand performance. Moreover, the equation reflects both the variations in and the general

  15. The results of surgical and nonsurgical treatment of mallet finger

    Directory of Open Access Journals (Sweden)

    Starčević Branislav

    2006-01-01

    Full Text Available Introduction: The injury of the hand tendon classified as mallet finger presents the loss of continuity of the united lateral band of the extensor apparatus above distal interphalangeal joint, which consequently leads to specific deformity of distal interphalangeal joint which is called mallet (hammer finger. Objective Our paper had several research Objectives: presentation of the existing Results of surgical and nonsurgical treatment of mallet finger deformities and comparison of our findings and other authors’ Results. Method: The study was retro-prospective, and analyzed 62 patients treated in the Clinical Center of Serbia in Belgrade (at the Institute of Orthopedic Surgery and Traumatology, and the Emergency Center in the period 1998 to 2003. The follow up of these patients lasted at least 8 months (from 8.3 months to 71.7 months. An average follow up was 28.7 months. The Objective parameters used in the study were as follows: sex, age, dominating hand, hand injury, finger injury, mode of treatment, complications, distal interphalangeal joint flexion and total movement of the distal interphalangeal joint. Collected data were analyzed by χ2-test and Student’s t-test. The confidence interval was p=0.05. Results: A total range of motion was 51.9±6.6 for nonsurgically treated patients, and 48.2±4.2 degrees for operated patients. Mean extension deficit of the distal interphalangeal joint was 6.5±3.3 for nonsurgical and 10.0±3.2 for operated patients. Conclusion: The Results confirmed that nonsurgical mode of treatment of mallet finger deformity was much more successful than surgical Method of treating the same deformity.

  16. Multi-finger prehension: control of a redundant mechanical system.

    Science.gov (United States)

    Latash, Mark L; Zatsiorsky, Vladimir M

    2009-01-01

    The human hand has been a fascinating object of study for researchers in both biomechanics and motor control. Studies of human prehension have contributed significantly to the progress in addressing the famous problem of motor redundancy. After a brief review of the hand mechanics, we present results of recent studies that support a general view that the apparently redundant design of the hand is not a source of computational problems but a rich apparatus that allows performing a variety of tasks in a reliable and flexible way (the principle of abundance). Multi-digit synergies have been analyzed at two levels of a hypothetical hierarchy involved in the control of prehensile actions. At the upper level, forces and moments produced by the thumb and virtual finger (an imagined finger with a mechanical action equal to the combined mechanical action of all four fingers of the hand) co-vary to stabilize the gripping action and the orientation of the hand-held object. These results support the principle of superposition suggested earlier in robotics with respect to the control of artificial grippers. At the lower level of the hierarchy, forces and moments produced by individual fingers co-vary to stabilize the magnitude and direction of the force vector and the moment of force produced by the virtual finger. Adjustments to changes in task constraints (such as, for example, friction under individual digits) may be local and synergic. The latter reflect multi-digit prehension synergies and may be analyzed with the so-called chain effects: Sequences of relatively straightforward cause-effect links directly related to mechanical constraints leading to non-trivial strong co-variation between pairs of elemental variables. Analysis of grip force adjustments during motion of hand-held objects suggests that the central nervous system adjusts to gravitational and inertial loads differently. The human hand is a gold mine for researchers interested in the control of natural human

  17. Finger and foot tapping sensor system for objective motor assessment

    Directory of Open Access Journals (Sweden)

    Đurić-Jovičić Milica

    2018-01-01

    Full Text Available Background/Aim. Finger tapping test is commonly used in neurological examinations as a test of motor performance. The new system comprising inertial and force sensors and custom proprietary software was developed for quantitative estimation and assessment of finger and foot tapping tests. The aim of this system was to provide diagnosis support and objective assessment of motor function. Methods. Miniature inertial sensors were placed on fingertips and used for measuring finger movements. A force sensor was placed on the fingertip of one finger, in order to measure the force during tapping. For foot tapping assessment, an inertial sensor was mounted on the subject’s foot, which was placed above a force platform. By using this system, various parameters such as a number of taps, tapping duration, rhythm, open and close speed, the applied force and tapping angle, can be extracted for detailed analysis of a patient’s motor performance. The system was tested on 13 patients with Parkinson’s disease and 14 healthy controls. Results. The system allowed easy measurement of listed parameters, and additional graphical representation showed quantitative differences in these parameters between neurological patient and healthy subjects. Conclusion. The novel system for finger and foot tapping test is compact, simple to use and efficiently collects patient data. Parameters measured in patients can be compared to those measured in healthy subjects, or among groups of patients, or used to monitor progress of the disease, or therapy effects. Created data and scores could be used together with the scores from clinical tests, providing the possibility for better insight into the diagnosis. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 175090 and Grant no. 175016

  18. Intravascular papillary endothelial hyperplasia: magnetic resonance imaging of finger lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Jinkyeong; Kim, Jee-Young [The Catholic University of Korea, Department of Radiology, St. Vincent' s Hospital, College of Medicine, Suwon, Gyeonggi-do (Korea, Republic of); Yoo, Changyoung [The Catholic University of Korea, Department of Hospital Pathology, St. Vincent' s Hospital, College of Medicine, Suwon, Gyeonggi-do (Korea, Republic of)

    2016-02-15

    To describe magnetic resonance imaging (MRI) features of intravascular papillary endothelial hyperplasia (IPEH), to identify findings differentiating IPEH of the finger from that of other locations, and to correlate these with pathology. Nineteen patients with 20 I.E. masses of the finger (n = 13) and other locations (n = 7) were evaluated. All patients underwent MRI, and the results were correlated with pathology. Seventeen IPEHs, including all IPEHs of the finger, were located in the subcutis, the three other lesions in the muscle layer. On T1WI, all masses were isointense or slightly hyperintense. IPEHs of the finger (n = 13) revealed focal hyperintense nodules (n = 2) or central hypointensity (n = 2) on T1WI, hypointensity with a hyperintense rim (n = 7), hyperintensity with hypointense nodules (n = 5), or isointensity with a hypointense rim (n = 1) on T2WI, and rim enhancement (n = 5), heterogeneous enhancement with nodular nonenhanced areas (n = 6), peripheral nodular enhancement (n = 1), or no enhancement (n = 1) on gadolinium-enhanced T1WI. IPEHs of other locations (n = 7) demonstrated focal hyperintense nodules (n = 5) on T1WI, hyperintensity with hypointense nodules (n = 5) or heterogeneous signal intensity (n = 2) on T2WI, and rim or rim and septal enhancement (n = 6) or peripheral nodular enhancement (n = 1). Microscopically, IPEHs were composed of thrombi that were hypointense on T2WI and papillary endothelial proliferations that showed T2 hyperintensity and enhancement. MRI of finger IPEH reveals well-demarcated subcutaneous masses with hypointensity or hypointense nodules with peripheral hyperintensity on T2WI, as well as peripheral enhancement. T1 hyperintense nodules, internal heterogeneity on T2WI, and septal enhancement are more common in IPEH of other locations. (orig.)

  19. Distinct neural control of intrinsic and extrinsic muscles of the hand during single finger pressing

    NARCIS (Netherlands)

    Dupan, Sigrid S.G.; Stegeman, Dick F.; Maas, Huub

    2018-01-01

    Single finger force tasks lead to unintended activation of the non-instructed fingers, commonly referred to as enslaving. Both neural and mechanical factors have been associated with this absence of finger individuality. This study investigates the amplitude modulation of both intrinsic and

  20. Squamous cell carcinoma of the finger masquerading as an abscess. Case report.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    A 43-year-old man presented with an abscess on his left ring finger, which recurred despite multiple drainage procedures. Histological examination of the lesion was unhelpful; it was only on histopathological examination of the finger after ray amputation that the diagnosis of cutaneous squamous cell carcinoma was established. This case illustrates the need to consider malignancy when dealing with chronic finger infections.

  1. Computer simulation of viscous fingering in a lifting Hele-Shaw cell

    Indian Academy of Sciences (India)

    We simulate viscous fingering generated by separating two plates with a constant force, in a lifting Hele-Shaw cell. Variation in the patterns for different fluid viscosity and lifting force is studied. Viscous fingering is strongly affected by anisotropy. We report a computer simulation study of fingering patterns, where circular or ...

  2. Nature or Nurture in finger counting: a review on the determinants of the direction of number-finger mapping

    Directory of Open Access Journals (Sweden)

    Paola ePrevitali

    2011-12-01

    Full Text Available The spontaneous use of finger counting has been for long recognised as critical to the acquisition of number skills. Recently, the great interest on space-number associations shifted attention to the practice of finger counting itself, and specifically, to its spatial components. Besides general cross-cultural differences in mapping numbers onto fingers, contrasting results have been reported with regard to the directional features of this mapping. The key issue we address is to what extent directionality is culturally-mediated, i.e., linked to the conventional reading-writing system direction, and/or biologically determined, i.e. linked to hand dominance. Although the preferred starting hand for counting seems to depend on the surveyed population, even within the same population high inter-individual variability minimises the role of cultural factors. Even if so far largely overlooked, handedness represents a sound candidate for shaping finger counting direction. Here we discuss adults and developmental evidence in support of this view and we reconsider the plausibility of multiple and coexistent number-space mapping in physical and representational space.

  3. Dynamics of Linker Residues Modulate the Nucleic Acid Binding Properties of the HIV-1 Nucleocapsid Protein Zinc Fingers

    Science.gov (United States)

    Zargarian, Loussiné; Tisné, Carine; Barraud, Pierre; Xu, Xiaoqian; Morellet, Nelly; René, Brigitte; Mély, Yves; Fossé, Philippe; Mauffret, Olivier

    2014-01-01

    The HIV-1 nucleocapsid protein (NC) is a small basic protein containing two zinc fingers (ZF) separated by a short linker. It is involved in several steps of the replication cycle and acts as a nucleic acid chaperone protein in facilitating nucleic acid strand transfers occurring during reverse transcription. Recent analysis of three-dimensional structures of NC-nucleic acids complexes established a new property: the unpaired guanines targeted by NC are more often inserted in the C-terminal zinc finger (ZF2) than in the N-terminal zinc finger (ZF1). Although previous NMR dynamic studies were performed with NC, the dynamic behavior of the linker residues connecting the two ZF domains remains unclear. This prompted us to investigate the dynamic behavior of the linker residues. Here, we collected 15N NMR relaxation data and used for the first time data at several fields to probe the protein dynamics. The analysis at two fields allows us to detect a slow motion occurring between the two domains around a hinge located in the linker at the G35 position. However, the amplitude of motion appears limited in our conditions. In addition, we showed that the neighboring linker residues R29, A30, P31, R32, K33 displayed restricted motion and numerous contacts with residues of ZF1. Our results are fully consistent with a model in which the ZF1-linker contacts prevent the ZF1 domain to interact with unpaired guanines, whereas the ZF2 domain is more accessible and competent to interact with unpaired guanines. In contrast, ZF1 with its large hydrophobic plateau is able to destabilize the double-stranded regions adjacent to the guanines bound by ZF2. The linker residues and the internal dynamics of NC regulate therefore the different functions of the two zinc fingers that are required for an optimal chaperone activity. PMID:25029439

  4. Transfer of tactile perceptual learning to untrained neighboring fingers reflects natural use relationships.

    Science.gov (United States)

    Dempsey-Jones, Harriet; Harrar, Vanessa; Oliver, Jonathan; Johansen-Berg, Heidi; Spence, Charles; Makin, Tamar R

    2016-03-01

    Tactile learning transfers from trained to untrained fingers in a pattern that reflects overlap between the representations of fingers in the somatosensory system (e.g., neurons with multifinger receptive fields). While physical proximity on the body is known to determine the topography of somatosensory representations, tactile coactivation is also an established organizing principle of somatosensory topography. In this study we investigated whether tactile coactivation, induced by habitual inter-finger cooperative use (use pattern), shapes inter-finger overlap. To this end, we used psychophysics to compare the transfer of tactile learning from the middle finger to its adjacent fingers. This allowed us to compare transfer to two fingers that are both physically and cortically adjacent to the middle finger but have differing use patterns. Specifically, the middle finger is used more frequently with the ring than with the index finger. We predicted this should lead to greater representational overlap between the former than the latter pair. Furthermore, this difference in overlap should be reflected in differential learning transfer from the middle to index vs. ring fingers. Subsequently, we predicted temporary learning-related changes in the middle finger's representation (e.g., cortical magnification) would cause transient interference in perceptual thresholds of the ring, but not the index, finger. Supporting this, longitudinal analysis revealed a divergence where learning transfer was fast to the index finger but relatively delayed to the ring finger. Our results support the theory that tactile coactivation patterns between digits affect their topographic relationships. Our findings emphasize how action shapes perception and somatosensory organization. Copyright © 2016 the American Physiological Society.

  5. Thai Finger-Spelling Recognition Using a Cascaded Classifier Based on Histogram of Orientation Gradient Features

    Directory of Open Access Journals (Sweden)

    Kittasil Silanon

    2017-01-01

    Full Text Available Hand posture recognition is an essential module in applications such as human-computer interaction (HCI, games, and sign language systems, in which performance and robustness are the primary requirements. In this paper, we proposed automatic classification to recognize 21 hand postures that represent letters in Thai finger-spelling based on Histogram of Orientation Gradient (HOG feature (which is applied with more focus on the information within certain region of the image rather than each single pixel and Adaptive Boost (i.e., AdaBoost learning technique to select the best weak classifier and to construct a strong classifier that consists of several weak classifiers to be cascaded in detection architecture. We collected 21 static hand posture images from 10 subjects for testing and training in Thai letters finger-spelling. The parameters for the training process have been adjusted in three experiments, false positive rates (FPR, true positive rates (TPR, and number of training stages (N, to achieve the most suitable training model for each hand posture. All cascaded classifiers are loaded into the system simultaneously to classify different hand postures. A correlation coefficient is computed to distinguish the hand postures that are similar. The system achieves approximately 78% accuracy on average on all classifier experiments.

  6. The zinc finger transcription factor 191 is required for early embryonic development and cell proliferation

    International Nuclear Information System (INIS)

    Li Jianzhong; Chen Xia; Yang Hua; Wang Shuiliang; Guo Baoyu; Yu Long; Wang Zhugang; Fu Jiliang

    2006-01-01

    Human zinc finger protein 191 (ZNF191/ZNF24) was cloned and characterized as a SCAN family member, which shows 94% identity to its mouse homologue zinc finger protein 191 (Zfp191). ZNF191 can specifically interact with an intronic polymorphic TCAT repeat (HUMTH01) in the tyrosine hydroxylase (TH) gene. Allelic variations of HUMTH01 have been stated to have a quantitative silencing effect on TH gene expression and to correlate with quantitative and qualitative changes in the binding by ZNF191. Zfp191 is widely expressed during embryonic development and in multiple tissues and organs in adult. To investigate the functions of Zfp191 in vivo, we have used homologous recombination to generate mice that are deficient in Zfp191. Heterozygous Zfp191 +/- mice are normal and fertile. Homozygous Zfp191 -/- embryos are severely retarded in development and die at approximately 7.5 days post-fertilization. Unexpectedly, in Zfp191 -/- and Zfp191 +/- embryos, TH gene expression is not affected. Blastocyst outgrowth experiments and the RNA interference-mediated knockdown of ZNF191 in cultured cells revealed an essential role for Zfp191 in cell proliferation. In further agreement with this function, no viable Zfp191 -/- cell lines were obtained by derivation of embryonic stem (ES) cells from blastocysts of Zfp191 +/- intercrosses or by forced homogenotization of heterozygous ES cells at high concentrations of G418. These data show that Zfp191 is indispensable for early embryonic development and cell proliferation

  7. fMRI assessment of somatotopy in human Brodmann area 3b by electrical finger stimulation.

    Science.gov (United States)

    Kurth, R; Villringer, K; Mackert, B M; Schwiemann, J; Braun, J; Curio, G; Villringer, A; Wolf, K J

    1998-01-26

    Functional magnetic resonance imaging (fMRI) is capable of detecting focal brain activation induced by electrical stimulation of single fingers in human subjects. In eight subjects somatotopic arrangement of the second and fifth finger was found in Brodmann area 3b of the primary somatosensory cortex. In four subjects the representation area of the second finger was located lateral and inferior to the fifth finger; in one subject the somatotopy was reversed. In three subjects representation areas of the two fingers in Brodmann area 3b were found overlapping. Additional activated areas were found on the crown of ipsilateral and contralateral postcentral gyrus (Brodmann areas 1 and 2) and posterior parietal cortex.

  8. CUTANEOUS MYXOID CYST ON THE SCLEROTIC FINGER IN A PATIENT WITH DIFFUSE SYSTEMIC SCLEROSIS

    Directory of Open Access Journals (Sweden)

    Taeko Nakamura-Wakatsuki

    2013-10-01

    Full Text Available Skin tumors occurring on the scleroderma fingers are rarely seen. Swollen fingers are hallmarks of systemic sclerosis, and mucin deposition in the lesional skin is a constant feature in systemic sclerosis. Here we describe a case of cutaneous myxoid cyst on the flexor aspect of the sclerotic fingers in a patient with severe diffuse cutaneous systemic sclerosis. Cutaneous myxoid cyst is a relatively common benign tumor; however, cases of cutaneous myxoid cysts developing on the scleroderma fingers have not been reported to date. Mucin deposition in the sclerotic skin may be a predisposing factor in the induction of myxoid cyst on the scleroderma finger in our patient.

  9. Analysis and optimal design of an underactuated finger mechanism for LARM hand

    Science.gov (United States)

    Yao, Shuangji; Ceccarelli, Marco; Carbone, Giuseppe; Zhan, Qiang; Lu, Zhen

    2011-09-01

    This paper aims to present general design considerations and optimality criteria for underactuated mechanisms in finger designs. Design issues related to grasping task of robotic fingers are discussed. Performance characteristics are outlined as referring to several aspects of finger mechanisms. Optimality criteria of the finger performances are formulated after careful analysis. A general design algorithm is summarized and formulated as a suitable multi-objective optimization problem. A numerical case of an underactuated robot finger design for Laboratory of Robotics and Mechatronics (LARM) hand is illustrated with the aim to show the practical feasibility of the proposed concepts and computations.

  10. Involuntary Neuromuscular Coupling between the Thumb and Finger of Stroke Survivors during Dynamic Movement.

    Science.gov (United States)

    Jones, Christopher L; Kamper, Derek G

    2018-01-01

    Finger-thumb coordination is crucial to manual dexterity but remains incompletely understood, particularly following neurological injury such as stroke. While being controlled independently, the index finger and thumb especially must work in concert to perform a variety of tasks requiring lateral or palmar pinch. The impact of stroke on this functionally critical sensorimotor control during dynamic tasks has been largely unexplored. In this study, we explored finger-thumb coupling during close-open pinching motions in stroke survivors with chronic hemiparesis. Two types of perturbations were applied randomly to the index with a novel Cable-Actuated Finger Exoskeleton: a sudden joint acceleration stretching muscle groups of the index finger and a sudden increase in impedance in selected index finger joint(s). Electromyographic signals for specific thumb and index finger muscles, thumb tip trajectory, and index finger joint angles were recorded during each trial. Joint angle perturbations invoked reflex responses in the flexor digitorum superficialis (FDS), first dorsal interossei (FDI), and extensor digitorum communis muscles of the index finger and heteronymous reflex responses in flexor pollicis brevis of the thumb ( p  index finger joint impedance was suddenly increased, thumb tip movement was substantially increased, from 2 to 10 cm ( p  index finger impacting thumb activity. The degree of coupling modulated with the phase of motion. These findings reveal a potential mechanism for direct intervention to improve poststroke hand mobility and provide insight on prospective neurologically oriented therapies.

  11. Finger-vein and fingerprint recognition based on a feature-level fusion method

    Science.gov (United States)

    Yang, Jinfeng; Hong, Bofeng

    2013-07-01

    Multimodal biometrics based on the finger identification is a hot topic in recent years. In this paper, a novel fingerprint-vein based biometric method is proposed to improve the reliability and accuracy of the finger recognition system. First, the second order steerable filters are used here to enhance and extract the minutiae features of the fingerprint (FP) and finger-vein (FV). Second, the texture features of fingerprint and finger-vein are extracted by a bank of Gabor filter. Third, a new triangle-region fusion method is proposed to integrate all the fingerprint and finger-vein features in feature-level. Thus, the fusion features contain both the finger texture-information and the minutiae triangular geometry structure. Finally, experimental results performed on the self-constructed finger-vein and fingerprint databases are shown that the proposed method is reliable and precise in personal identification.

  12. Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors.

    Science.gov (United States)

    Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung

    2017-06-06

    Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods.

  13. Finger-gate manipulated quantum transport in Dirac materials

    International Nuclear Information System (INIS)

    Kleftogiannis, Ioannis; Cheng, Shun-Jen; Tang, Chi-Shung

    2015-01-01

    We investigate the quantum transport properties of multichannel nanoribbons made of materials described by the Dirac equation, under an in-plane magnetic field. In the low energy regime, positive and negative finger-gate potentials allow the electrons to make intra-subband transitions via hole-like or electron-like quasibound states (QBS), respectively, resulting in dips in the conductance. In the high energy regime, double dip structures in the conductance are found, attributed to spin-flip or spin-nonflip inter-subband transitions through the QBSs. Inverting the finger-gate polarity offers the possibility to manipulate the spin polarized electronic transport to achieve a controlled spin-switch. (paper)

  14. Heat Resistance of Glued Finger Joints in Spruce Wood Constructions

    Directory of Open Access Journals (Sweden)

    Martin Sviták

    2014-10-01

    Full Text Available The heat resistance of glued spruce wood was evaluated for different joint types and adhesives. Bending strength, modulus of elasticity, and also fracture evaluation were investigated on glued spruce samples made by the finger-jointed principle. Finger-jointed samples were glued with polyurethane (PUR and melamine-urea-formaldehyde (MUF adhesives. Heat loading was realized at temperatures 60, 80, and 110 °C and compared with wood with 20 °C. A static bending test with four-point flexural test was used. Elevated temperature and adhesive type had an important influence on the bending strength. On the other hand, adhesive type had a significant influence on the modulus of elasticity, but elevated temperature had no substantial influence.

  15. [10 congenital trigger fingers. Apropos of a case report].

    Science.gov (United States)

    Moutet, F; Lebrun, C; Sartorius, C

    1987-01-01

    Ten congenital triggers fingers have been treated on a 3 years old girl after correction of congenital bilateral club feet. Such a case, without any other congenital malformation seems to be unique in the French literature and only found twice in the English one. This child in spite of a normal growth and good psychomotor development, presents an unusual face, with a mouth a little bit too small, but her karyotype is normal. No trismus and no microstomia were found to enable this case to be classified in a specific syndrome. The right diagnosis may be a non evolutive arthrogryposis of the extremities. Dividing the ten proximal pulleys (A1) let 10 voluminous nodules pass through and allowed full range of motion in nine out of ten fingers. A remaining flexion deformity of the proximal interphalangeal joint needed an anterior arthrolysis, the final result was good.

  16. Acute Calcific Tendinitis of the Index Finger in a Child.

    Science.gov (United States)

    Walocko, Frances M; Sando, Ian C; Haase, Steven C; Kozlow, Jeffrey H

    2017-09-01

    Calcific tendinitis is characterized by calcium hydroxyapatite crystal deposition within tendons and is a common cause of musculoskeletal pain in adults. Its clinical manifestations may be acute, chronic, or asymptomatic. Acute calcific tendinitis is self-resolving condition that is rarely reported in the pediatric population and may be overlooked for more common processes, leading to unnecessary treatment. A chart reivew was performed of a single case of acute calcific tendonitis of the index finger in a child. We describe a case of calcific tendinitis of the index finger in a 9-year-old boy who was referred to us for a second opinion after surgical exploration of an acutely inflamed digit was recommended based on his initial presentation. The calcifications and symptoms resolved over time without operative management. Although rare in children, acute calcific tendinitis can present similar to an infection. However, appropriate managment is non-operative as the symptoms and radiographic findings resolve over time.

  17. Experimental Research on the Influence of Vibration on Fingers Mobility

    Directory of Open Access Journals (Sweden)

    Radu Panaitescu-Liess

    2013-09-01

    Full Text Available In many industrial activities the human body is exposed to vibrations transmitted through the hand-arm system. A long exposure to these vibrations can cause various health problems of blood vessels, nerves, muscles, bones, joints and upper limb [1]. This paper presents some considerations about the influence of vibration on finger joints mobility. I used a MediTouch system which consists of a motion capture device (an ergonomic glove and a dedicated software.

  18. The "Haptic Finger"- a new device for monitoring skin condition.

    Science.gov (United States)

    Tanaka, Mami; Lévêque, Jean Luc; Tagami, Hachiro; Kikuchi, Katsuko; Chonan, Seifi

    2003-05-01

    Touching the skin is of great importance for the Clinician for assessing roughness, softness, firmness, etc. This type of clinical assessment is very subjective and therefore non-reproducible from one Clinician to another one or even from time to time for the same Clinician. In order to objectively monitor skin texture, we developed a new sensor, placed directly on the Clinician's finger, which generate some electric signal when slid over the skin surface. The base of this Haptic Finger sensor is a thin stainless steel plate on which sponge rubber, PVDF foil, acetate film and gauze are layered. The signal generated by the sensor was filtered and digitally stored before processing. In a first in vitro experiment, the sensor was moved over different skin models (sponge rubber covered by silicon rubber) of varying hardness and roughness. These experiments allowed the definition of two parameters characterizing textures. The first parameter is variance of the signal processed using wavelet analysis, representing an index of roughness. The second parameter is dispersion of the power spectrum density in the frequency domain, corresponding to hardness. To validate these parameters, the Haptic Finger was used to scan skin surfaces of 30 people, 14 of whom displayed a skin disorder: xerosis (n = 5), atopic dermatitis (n = 7), and psoriasis (n = 2). The results obtained by means of the sensor were compared with subjective, clinical evaluations by a Clinician who scored both roughness and hardness of the skin. Good agreement was observed between clinical assessment of the skin and the two parameters generated using the Haptic Finger. Use of this sensor could prove extremely valuable in cosmetic research where skin surface texture (in terms of tactile properties) is difficult to measure.

  19. Calculated energy response of lithium fluoride finger-tip dosimeters

    International Nuclear Information System (INIS)

    Johns, T.F.

    1965-07-01

    Calculations have been made of the energy response of the lithium fluoride thermoluminescent dosimeters being used at A.E.E. Winfrith for the measurement of radiation doses to the finger-tips of people handling radio-active materials. It is shown that the energy response is likely to be materially affected if the sachet in which the powder is held contains elements with atomic numbers much higher than 9 (e.g. if the sachet is made from polyvinyl chloride). (author)

  20. Distinct neural control of intrinsic and extrinsic muscles of the hand during single finger pressing.

    Science.gov (United States)

    Dupan, Sigrid S G; Stegeman, Dick F; Maas, Huub

    2018-06-01

    Single finger force tasks lead to unintended activation of the non-instructed fingers, commonly referred to as enslaving. Both neural and mechanical factors have been associated with this absence of finger individuality. This study investigates the amplitude modulation of both intrinsic and extrinsic finger muscles during single finger isometric force tasks. Twelve participants performed single finger flexion presses at 20% of maximum voluntary contraction, while simultaneously the electromyographic activity of several intrinsic and extrinsic muscles associated with all four fingers was recorded using 8 electrode pairs in the hand and two 30-electrode grids on the lower arm. The forces exerted by each of the fingers, in both flexion and extension direction, were recorded with individual force sensors. This study shows distinct activation patterns in intrinsic and extrinsic hand muscles. Intrinsic muscles exhibited individuation, where the agonistic and antagonistic muscles associated with the instructed fingers showed the highest activation. This activation in both agonistic and antagonistic muscles appears to facilitate finger stabilisation during the isometric force task. Extrinsic muscles show an activation independent from instructed finger in both agonistic and antagonistic muscles, which appears to be associated with stabilisation of the wrist, with an additional finger-dependent modulation only present in the agonistic extrinsic muscles. These results indicate distinct muscle patterns in intrinsic and extrinsic hand muscles during single finger isometric force pressing. We conclude that the finger specific activation of intrinsic muscles is not sufficient to fully counteract enslaving caused by the broad activation of the extrinsic muscles. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Coherent normalization of finger strontium XRF measurements: feasibility and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Zamburlini, M; Pejovic-Milic, A; Chettle, D R [Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, L8S 4K1 (Canada)

    2008-08-07

    A non-invasive in vivo x-ray fluorescence (XRF) method of measuring bone strontium concentrations has previously been reported as a potential diagnostic tool able to detect strontium concentration in the finger and ankle bones. The feasibility of coherent normalization for {sup 125}I-source-based finger bone strontium x-ray fluorescence (XRF) measurements is assessed here by theoretical considerations and Monte Carlo simulations. Normalization would have several advantages, among which are the correction for the signal attenuation by the overlying soft tissue, and intersubject variability in the bone size and shape. The coherent normalization of bone strontium XRF measurements presents several challenges dictated by the behaviour of the coherent cross section and mass attenuation coefficient at the energies involved. It was found that the coherent normalization alone with either 22.1 keV or 35.5 keV photons was not successful in correcting for the overlying soft tissue attenuation. However, it was found that the coherent peak at 35.5 keV was able to correct effectively for variability in the finger bone size between people. Thus, it is suggested that, if the overlying soft tissue thickness can be obtained by means of an independent measurement, the 35.5 keV peak can be used to correct for the bone size, with an overall accuracy of the normalization process of better than 10%. (note)

  2. Quantification of Finger-Tapping Angle Based on Wearable Sensors.

    Science.gov (United States)

    Djurić-Jovičić, Milica; Jovičić, Nenad S; Roby-Brami, Agnes; Popović, Mirjana B; Kostić, Vladimir S; Djordjević, Antonije R

    2017-01-25

    We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems.

  3. Rhythmic finger tapping reveals cerebellar dysfunction in essential tremor.

    Science.gov (United States)

    Buijink, A W G; Broersma, M; van der Stouwe, A M M; van Wingen, G A; Groot, P F C; Speelman, J D; Maurits, N M; van Rootselaar, A F

    2015-04-01

    Cerebellar circuits are hypothesized to play a central role in the pathogenesis of essential tremor. Rhythmic finger tapping is known to strongly engage the cerebellar motor circuitry. We characterize cerebellar and, more specifically, dentate nucleus function, and neural correlates of cerebellar output in essential tremor during rhythmic finger tapping employing functional MRI. Thirty-one propranolol-sensitive essential tremor patients with upper limb tremor and 29 healthy controls were measured. T2*-weighted EPI sequences were acquired. The task consisted of alternating rest and finger tapping blocks. A whole-brain and region-of-interest analysis was performed, the latter focusing on the cerebellar cortex, dentate nucleus and inferior olive nucleus. Activations were also related to tremor severity. In patients, dentate activation correlated positively with tremor severity as measured by the tremor rating scale part A. Patients had reduced activation in widespread cerebellar cortical regions, and additionally in the inferior olive nucleus, and parietal and frontal cortex, compared to controls. The increase in dentate activation with tremor severity supports involvement of the dentate nucleus in essential tremor. Cortical and cerebellar changes during a motor timing task in essential tremor might point to widespread changes in cerebellar output in essential tremor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Abnormal maximal finger tapping in abstinent cannabis users.

    Science.gov (United States)

    Flavel, Stanley C; White, Jason M; Todd, Gabrielle

    2013-11-01

    To investigate movement speed and rhythmicity in abstinent cannabis users, we hypothesized that abstinent cannabis users exhibit decreased maximal finger tapping frequency and increased variability of tapping compared with non-drug users. The study involved 10 healthy adult cannabis users and 10 age-matched and gender-matched controls with no history of illicit drug use. Subjects underwent a series of screening tests prior to participation. Subjects were then asked to tap a strain gauge as fast as possible with the index finger of their dominant hand (duration 5 s). The average intertap interval did not significantly differ between groups, but the coefficient of variation of the intertap interval was significantly greater in the cannabis group than in controls (p=0.011). The cannabis group also exhibited a slow tapping frequency at the beginning of the task. Rhythmicity of finger tapping is abnormal in individuals with a history of cannabis use. The abnormality appears to be long lasting and adds to the list of functional changes present in abstinent cannabis users. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Post-exercise cortical depression following repetitive passive finger movement.

    Science.gov (United States)

    Otsuka, Ryohei; Sasaki, Ryoki; Tsuiki, Shota; Kojima, Sho; Onishi, Hideaki

    2017-08-24

    This study aimed to clarify the influence of range of repetitive passive finger movement on corticospinal excitability. Thirteen healthy subjects participated in this study. Passive index finger adduction-abduction movements were performed from 15° abduction to 15° adduction, 15° abduction to 0°, 0° to 15° adduction, and 15° adduction to 30° adduction, each at 15°/s for 10min on separate days. Motor evoked potentials (MEPs) elicited by transcranial magnetic stimulation and M- and F-waves were measured before and after each repetitive passive index finger movement protocol to evaluate changes in corticospinal excitability. MEP amplitude significantly decreased after all passive movements, while F-wave amplitude, F-wave persistence, and M-wave amplitude remained stable. These results suggest that cortical excitability decreases after repetitive passive movement. However, the range of repetitive passive movement does not markedly influence the magnitude of cortical depression. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Ultrasound of the fingers for human identification using biometrics.

    Science.gov (United States)

    Narayanasamy, Ganesh; Fowlkes, J Brian; Kripfgans, Oliver D; Jacobson, Jon A; De Maeseneer, Michel; Schmitt, Rainer M; Carson, Paul L

    2008-03-01

    It was hypothesized that the use of internal finger structure as imaged using commercially available ultrasound (US) scanners could act as a supplement to standard methods of biometric identification, as well as a means of assessing physiological and cardiovascular status. Anatomical structures in the finger including bone contour, tendon and features along the interphalangeal joint were investigated as potential biometric identifiers. Thirty-six pairs of three-dimensional (3D) gray-scale images of second to fourth finger (index, middle and ring) data taken from 20 individuals were spatially registered using MIAMI-Fuse software developed at our institution and also visually matched by four readers. The image-based registration met the criteria for matching successfully in 14 out of 15 image pairs on the same individual and did not meet criteria for matching in any of the 12 image pairs from different subjects, providing a sensitivity and specificity of 0.93 and 1.00, respectively. Visual matching of all image pairs by four readers yielded 96% successful match. Power Doppler imaging was performed to calculate the change in color pixel density due to physical exercise as a surrogate of stress level and to provide basic physiological information. (E-mail: gnarayan@umich.edu).

  7. Finger vein recognition based on the hyperinformation feature

    Science.gov (United States)

    Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Yang, Lu

    2014-01-01

    The finger vein is a promising biometric pattern for personal identification due to its advantages over other existing biometrics. In finger vein recognition, feature extraction is a critical step, and many feature extraction methods have been proposed to extract the gray, texture, or shape of the finger vein. We treat them as low-level features and present a high-level feature extraction framework. Under this framework, base attribute is first defined to represent the characteristics of a certain subcategory of a subject. Then, for an image, the correlation coefficient is used for constructing the high-level feature, which reflects the correlation between this image and all base attributes. Since the high-level feature can reveal characteristics of more subcategories and contain more discriminative information, we call it hyperinformation feature (HIF). Compared with low-level features, which only represent the characteristics of one subcategory, HIF is more powerful and robust. In order to demonstrate the potential of the proposed framework, we provide a case study to extract HIF. We conduct comprehensive experiments to show the generality of the proposed framework and the efficiency of HIF on our databases, respectively. Experimental results show that HIF significantly outperforms the low-level features.

  8. Direct Numerical Simulation of Fingering Instabilities in Coating Flows

    Science.gov (United States)

    Eres, Murat H.; Schwartz, Leonard W.

    1998-11-01

    We consider stability and finger formation in free surface flows. Gravity driven downhill drainage and temperature gradient driven climbing flows are two examples of such problems. The former situation occurs when a mound of viscous liquid on a vertical wall is allowed to flow. Constant surface shear stress due to temperature gradients (Marangoni stress) can initiate the latter problem. The evolution equations are derived using the lubrication approximation. We also include the effects of finite-contact angles in the evolution equations using a disjoining pressure model. Evolution equations for both problems are solved using an efficient alternating-direction-implicit method. For both problems a one-dimensional base state is established, that is steady in a moving reference frame. This base state is unstable to transverse perturbations. The transverse wavenumbers for the most rapidly growing modes are found through direct numerical solution of the nonlinear evolution equations, and are compared with published experimental results. For a range of finite equilibrium contact angles, the fingers can grow without limit leading to semi-finite steady fingers in a moving coordinate system. A computer generated movie of the nonlinear simulation results, for several sets of input parameters, will be shown.

  9. Online Signature Verification on MOBISIG Finger-Drawn Signature Corpus

    Directory of Open Access Journals (Sweden)

    Margit Antal

    2018-01-01

    Full Text Available We present MOBISIG, a pseudosignature dataset containing finger-drawn signatures from 83 users captured with a capacitive touchscreen-based mobile device. The database was captured in three sessions resulting in 45 genuine signatures and 20 skilled forgeries for each user. The database was evaluated by two state-of-the-art methods: a function-based system using local features and a feature-based system using global features. Two types of equal error rate computations are performed: one using a global threshold and the other using user-specific thresholds. The lowest equal error rate was 0.01% against random forgeries and 5.81% against skilled forgeries using user-specific thresholds that were computed a posteriori. However, these equal error rates were significantly raised to 1.68% (random forgeries case and 14.31% (skilled forgeries case using global thresholds. The same evaluation protocol was performed on the DooDB publicly available dataset. Besides verification performance evaluations conducted on the two finger-drawn datasets, we evaluated the quality of the samples and the users of the two datasets using basic quality measures. The results show that finger-drawn signatures can be used by biometric systems with reasonable accuracy.

  10. Compensating Pose Uncertainties through Appropriate Gripper Finger Cutouts

    Directory of Open Access Journals (Sweden)

    Wolniakowski Adam

    2018-03-01

    Full Text Available The gripper finger design is a recurring problem in many robotic grasping platforms used in industry. The task of switching the gripper configuration to accommodate for a new batch of objects typically requires engineering expertise, and is a lengthy and costly iterative trial-and-error process. One of the open challenges is the need for the gripper to compensate for uncertainties inherent to the workcell, e.g. due to errors in calibration, inaccurate pose estimation from the vision system, or object deformation. In this paper, we present an analysis of gripper uncertainty compensating capabilities in a sample industrial object grasping scenario for a finger that was designed using an automated simulation-based geometry optimization method (Wolniakowski et al., 2013, 2015. We test the developed gripper with a set of grasps subjected to structured perturbation in a simulation environment and in the real-world setting. We provide a comparison of the data obtained by using both of these approaches. We argue that the strong correspondence observed in results validates the use of dynamic simulation for the gripper finger design and optimization.

  11. A finger leaf design for dual layer MLCs

    International Nuclear Information System (INIS)

    Cui Weijie; Dai Jianrong

    2010-01-01

    Objective: To introduce a finger leaf design that is applied to dual layer MLCs. Methods: An optimization model was firstly constructed to describe the problem of determining leaf end shapes,and the corresponding problems were then solved by the simplex search method or the simulated annealing technique. Optimal parameters for arc shapes of leaf end projections were obtained, and a comparison was done between optimized MLCs and conventional MLCs in terms of field conformity. The optimization process was based on 634 target fields selected from the patient data base of a treatment planning system. Areas of these fields ranged from 20.0 to 602.7 cm with a mean and its standard deviation of (125.7 ± 0.0) cm 2 . Results: The optimized leaf end shapes projected to the isocenter plane were semicircles. With the finger leaf design, the total area of discrepancy regions between MLC fields and target fields was reduced by 32.3%. Conclusions: The finger leaf design improves the conformity of the MLC shaped fields to the desired target fields. (authors)

  12. Dynamic modulation of corticospinal excitability and short-latency afferent inhibition during onset and maintenance phase of selective finger movement.

    Science.gov (United States)

    Cho, Hyun Joo; Panyakaew, Pattamon; Thirugnanasambandam, Nivethida; Wu, Tianxia; Hallett, Mark

    2016-06-01

    During highly selective finger movement, corticospinal excitability is reduced in surrounding muscles at the onset of movement but this phenomenon has not been demonstrated during maintenance of movement. Sensorimotor integration may play an important role in selective movement. We sought to investigate how corticospinal excitability and short-latency afferent inhibition changes in active and surrounding muscles during onset and maintenance of selective finger movement. Using transcranial magnetic stimulation (TMS) and paired peripheral stimulation, input-output recruitment curve and short-latency afferent inhibition (SAI) were measured in the first dorsal interosseus and abductor digiti minimi muscles during selective index finger flexion. Motor surround inhibition was present only at the onset phase, but not at the maintenance phase of movement. SAI was reduced at onset but not at the maintenance phase of movement in both active and surrounding muscles. Our study showed dynamic changes in corticospinal excitability and sensorimotor modulation for active and surrounding muscles in different movement states. SAI does not appear to contribute to motor surround inhibition at the movement onset phase. Also, there seems to be different inhibitory circuit(s) other than SAI for the movement maintenance phase in order to delineate the motor output selectively when corticospinal excitability is increased in both active and surrounding muscles. This study enhances our knowledge of dynamic changes in corticospinal excitability and sensorimotor interaction in different movement states to understand normal and disordered movements. Published by Elsevier Ireland Ltd.

  13. An Arginine Finger Regulates the Sequential Action of Asymmetrical Hexameric ATPase in the Double-Stranded DNA Translocation Motor.

    Science.gov (United States)

    Zhao, Zhengyi; De-Donatis, Gian Marco; Schwartz, Chad; Fang, Huaming; Li, Jingyuan; Guo, Peixuan

    2016-10-01

    Biological motors are ubiquitous in living systems. Currently, how the motor components coordinate the unidirectional motion is elusive in most cases. Here, we report that the sequential action of the ATPase ring in the DNA packaging motor of bacteriophage ϕ29 is regulated by an arginine finger that extends from one ATPase subunit to the adjacent unit to promote noncovalent dimer formation. Mutation of the arginine finger resulted in the interruption of ATPase oligomerization, ATP binding/hydrolysis, and DNA translocation. Dimer formation reappeared when arginine mutants were mixed with other ATPase subunits that can offer the arginine to promote their interaction. Ultracentrifugation and virion assembly assays indicated that the ATPase was presenting as monomers and dimer mixtures. The isolated dimer alone was inactive in DNA translocation, but the addition of monomer could restore the activity, suggesting that the hexameric ATPase ring contained both dimer and monomers. Moreover, ATP binding or hydrolysis resulted in conformation and entropy changes of the ATPase with high or low DNA affinity. Taking these observations together, we concluded that the arginine finger regulates sequential action of the motor ATPase subunit by promoting the formation of the dimer inside the hexamer. The finding of asymmetrical hexameric organization is supported by structural evidence of many other ATPase systems showing the presence of one noncovalent dimer and four monomer subunits. All of these provide clues for why the asymmetrical hexameric ATPase gp16 of ϕ29 was previously reported as a pentameric configuration by cryo-electron microscopy (cryo-EM) since the contact by the arginine finger renders two adjacent ATPase subunits closer than other subunits. Thus, the asymmetrical hexamer would appear as a pentamer by cryo-EM, a technology that acquires the average of many images. Copyright © 2016 Zhao et al.

  14. Quantitative assessment of finger motor impairment in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Laura Bonzano

    Full Text Available OBJECTIVE: To address the disability impact on fine hand motor functions in patients with Multiple Sclerosis (MS by quantitatively measuring finger opposition movements, with the aim of providing a new "score" integrating current methods for disability assessment. METHODS: 40 MS patients (Expanded Disability Status Scale (EDSS: 0-7 and 80 healthy controls (HC performed a repetitive finger-to-thumb opposition sequence with their dominant hand at spontaneous and maximal velocity, and uni- and bi-manually metronome-paced. A sensor-engineered glove was used to measure finger motor performance. Twenty-seven HC were tested twice, one month apart, to assess test-retest reliability. RESULTS: The motor parameters showed a good reproducibility in HC and demonstrated significantly worse performance in MS patients with respect to HC. A multivariate model revealed that rate of movement in the spontaneous velocity condition and inter-hand interval (IHI, indicating bimanual coordination, contributed independently to differentiate the two groups. A finger motor impairment score based on these two parameters was able to discriminate HC from MS patients with very low EDSS scores (p<0.001: a significant difference was already evident for patients with EDSS = 0. Further, in the MS group, some motor performance parameters correlated with the clinical scores. In particular, significant correlations were found between IHI and EDSS (r = 0.56; p<0.0001, MS Functional Composite (r = -0.40; p = 0.01, Paced Auditory Serial Addition (r = -0.38; p = 0.02. No motor performance parameter correlated with Timed 25-Foot Walk. CONCLUSIONS: A simple, quantitative, objective method measuring finger motor performance could be used to define a score discriminating healthy controls and MS patients, even with very low disability. This sensitivity might be of crucial importance for monitoring the disease course and the treatment effects in early MS patients, when

  15. Use of Mutation Breeding Technique in Improving Finger Millet in Northern Zambia

    International Nuclear Information System (INIS)

    Msikita, R.N.

    2002-01-01

    Many breeders have observed that induced mutation increases genetic variability, and the expose to mutagenic agents increases mutation frequency. Studies have indicated the effect in height reduction, increased yield components,disease resistance, in crop like rice and wheat. A study was conducted in finger millet in thr Northern part of Zambia (Region III), a high rainfall area, aiming at improving finger length, number of fingers till ring capacity in order to increase the yield. the seed of Nyika variety, popular to farmers due to its medium maturity, palm shaped fingers (six fingers on average), and light brown grain. Three quantities of seed were irradiated at 15Kr, 20Kr and 30Kr doses. A dose of 15Kr of gamma rays irradiation continued to create good genetic change in the exposed material. These observations clearly suggest that 15Kr dose of gamma rays is the optimum one to expose/irradiate finger millet to create desired genetic changes. The results of 2000/2001 were not significantly different. However, FMM 165 had better yields (3193 Kg) than FMM 175 in Misamfu, while FMM 175 yielded better (3272 Kg) in Chinsali. During 2001/2002 both FMMs performed well in the national finger number of 10 per head. There were also highly significant differences among finger lengths.FMM 165 had finger length of 10.3 cm. Concerning grain yield FMM 165 and FMM 175 had 3802 and 3864 Kg/ha, respectively, which were above the overall mean 3864 Kg/ha. Grain yield correlated positively with finger number with an r-value of 0.19 and finger length r-value of 0.22 although it was not significant at 1% or 5%. Meanwhile in the advance trial there were significant differences among genotypes in finger number. Both FMMs had 9 fingers above the overall mean of 8.8. In the finger length there were highly significant differences. FMM 175 had a length of 11.5 cm while FMM 165 had 10.4 cm. There were highly significant differences among the genotypes in yield. FMM 165 (4636 Kg) and FMM 175

  16. Multimodal biometric method that combines veins, prints, and shape of a finger

    Science.gov (United States)

    Kang, Byung Jun; Park, Kang Ryoung; Yoo, Jang-Hee; Kim, Jeong Nyeo

    2011-01-01

    Multimodal biometrics provides high recognition accuracy and population coverage by using various biometric features. A single finger contains finger veins, fingerprints, and finger geometry features; by using multimodal biometrics, information on these multiple features can be simultaneously obtained in a short time and their fusion can outperform the use of a single feature. This paper proposes a new finger recognition method based on the score-level fusion of finger veins, fingerprints, and finger geometry features. This research is novel in the following four ways. First, the performances of the finger-vein and fingerprint recognition are improved by using a method based on a local derivative pattern. Second, the accuracy of the finger geometry recognition is greatly increased by combining a Fourier descriptor with principal component analysis. Third, a fuzzy score normalization method is introduced; its performance is better than the conventional Z-score normalization method. Fourth, finger-vein, fingerprint, and finger geometry recognitions are combined by using three support vector machines and a weighted SUM rule. Experimental results showed that the equal error rate of the proposed method was 0.254%, which was lower than those of the other methods.

  17. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation......The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...

  18. Sliding Window-Based Region of Interest Extraction for Finger Vein Images

    Science.gov (United States)

    Yang, Lu; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2013-01-01

    Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. PMID:23507824

  19. Kinematic design of a finger abduction mechanism for an anthropomorphic robotic hand

    Directory of Open Access Journals (Sweden)

    L.-A. A. Demers

    2011-02-01

    Full Text Available This paper presents the kinematic design of an abduction mechanism for the fingers of an underactuated anthropomorphic robotic hand. This mechanism will enhance the range of feasible grasps of the underactuated hand without significantly increasing its complexity. The analysis of the link between the index finger and the third finger is first assessed, where the parameters are studied in order to follow the amplitude constraint and to minimize the coordination error. Then, the study of the mechanism joining the third finger and the little finger is summarized. Finally, a prototype of the finger's abduction system is presented.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  20. Generation of dense plume fingers in saturated-unsaturated homogeneous porous media

    Science.gov (United States)

    Cremer, Clemens J. M.; Graf, Thomas

    2015-02-01

    Flow under variable-density conditions is widespread, occurring in geothermal reservoirs, at waste disposal sites or due to saltwater intrusion. The migration of dense plumes typically results in the formation of vertical plume fingers which are known to be triggered by material heterogeneity or by variations in source concentration that causes the density variation. Using a numerical groundwater model, six perturbation methods are tested under saturated and unsaturated flow conditions to mimic heterogeneity and concentration variations on the pore scale in order to realistically generate dense fingers. A laboratory-scale sand tank experiment is numerically simulated, and the perturbation methods are evaluated by comparing plume fingers obtained from the laboratory experiment with numerically simulated fingers. Dense plume fingering for saturated flow can best be reproduced with a spatially random, time-constant perturbation of the solute source. For unsaturated flow, a spatially and temporally random noise of solute concentration or a random conductivity field adequately simulate plume fingering.

  1. Association between finger tapping, attention, memory, and cognitive diagnosis in elderly patients.

    Science.gov (United States)

    Rabinowitz, Israel; Lavner, Yizhar

    2014-08-01

    This study examined the association between spontaneous finger tapping and cognitive function, with a detailed analysis of the two main phases of finger tapping, the touch-phase and the off-phase. 170 elderly patients (83 men, 87 women; M age = 82.1 yr., SD = 6.2) underwent cognitive assessment including the Mini-Mental State Examination, a forward digit span test, and 15 sec. of finger tapping. Results indicated a significant increase in the length and variability of the finger-touch phase among participants with mild cognitive impairment or dementia compared to participants with no cognitive impairment, suggesting a relationship between finger tapping and attention, short-term memory, and cognitive diagnosis. Pattern classification analyses on the finger tapping parameters indicated a specificity of 0.91 and sensitivity of 0.52 for ruling out cognitive impairment.

  2. A PZT Actuated Triple-Finger Gripper for Multi-Target Micromanipulation

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2017-01-01

    Full Text Available This paper presents a triple-finger gripper driven by a piezoceramic (PZT transducer for multi-target micromanipulation. The gripper consists of three fingers assembled on adjustable pedestals with flexible hinges for a large adjustable range. Each finger has a PZT actuator, an amplifying structure, and a changeable end effector. The moving trajectories of single and double fingers were calculated and finite element analyses were performed to verify the reliability of the structures. In the gripping experiment, various end effectors of the fingers such as tungsten probes and fibers were tested, and different micro-objects such as glass hollow spheres and iron spheres with diameters ranging from 10 to 800 μm were picked and released. The output resolution is 145 nm/V, and the driven displacement range of the gripper is 43.4 μm. The PZT actuated triple-finger gripper has superior adaptability, high efficiency, and a low cost.

  3. Finger image quality based on singular point localization

    DEFF Research Database (Denmark)

    Wang, Jinghua; Olsen, Martin A.; Busch, Christoph

    2014-01-01

    Singular points are important global features of fingerprints and singular point localization is a crucial step in biometric recognition. Moreover the presence and position of the core point in a captured fingerprint sample can reflect whether the finger is placed properly on the sensor. Therefore...... and analyze the importance of singular points on biometric accuracy. The experiment is based on large scale databases and conducted by relating the measured quality of a fingerprint sample, given by the positions of core points, to the biometric performance. The experimental results show the positions of core...

  4. Person recognition using fingerprints and top-view finger images

    Directory of Open Access Journals (Sweden)

    Panyayot Chaikan

    2010-03-01

    Full Text Available Our multimodal biometric system combines fingerprinting with a top-view finger image captured by a CCD camera without user intervention. The greyscale image is preprocessed to enhance its edges, skin furrows, and the nail shape before being manipulated by a bank of oriented filters. A square tessellation is applied to the filtered image to create a feature map, called a NailCode, which is employed in Euclidean distance computations. The NailCode reduces system errors by 17.68% in the verification mode, and by 6.82% in the identification mode.

  5. Occult lung malignancy presenting with finger pain: a case report

    Directory of Open Access Journals (Sweden)

    Embley Matthew A

    2008-12-01

    Full Text Available Abstract Introduction Lung cancer is currently one of the most common malignancies in the world. Early detection is an important prognostic factor. Unfortunately, initial symptoms may be vague and a substantial proportion of cases present with the effects of metastases. Case presentation We discuss a case of occult lung malignancy in a 61-year-old man. The only symptom at presentation was pain in the right ring finger due to metastasis from the lung primary. Conclusion This case highlights the need for vigilance when a patient presents with unusual or unexplained symptoms, especially if they have known risk factors for cancer.

  6. Optical Three-Axis Tactile Sensor for Robotic Fingers

    OpenAIRE

    Ohka, Masahiro; Takata, Jumpei; Kobayashi, Hiroaki; Suzuki, Hirofumi; Morisawa, Nobuyuki; Yussof, Hanafiah Bin

    2008-01-01

    A new three-axis tactile sensor to be mounted on multi-fingered hands is developed based on the principle of an optical waveguide-type tactile sensor comprised of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera. The sensing element of the present tactile sensor includes one columnar feeler and eight conical feelers. A three-axis force applied to the tip of the sensing element is detected by the contact areas of the conical feelers, which ma...

  7. HE upgrade beyond phase 1. Finger scintillator option.

    CERN Document Server

    Afanasiev, Sergey; Boyarintsev, A.Yu; Emeliantchik, Igor; Golutvin, Igor; Grinyov, B.V; Ershov, Yuri; Levchuk, Leonid; Litomin, Aliaksandr; Malakhov, Alexander; Moisenz, Petr; Popov, V.F; Shumeiko, Nikolai; Smirnov, Vitaly; Sorokin, Pavlo; Zhmurin, Petro

    2014-01-01

    CMS hadron calorimeters (HB, HE, HO) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The endcap calorimeter HE suffered more radiation damage than anticipated causing rapid degradation of scintillator segments (tiles) which have a higher radiation flux from secondary particles than HB and HO. A proposal to upgrade of HE calorimeter will provide a solution for survivability at future LHC higher luminosity. A finger-strip plastic scintillator option has many advantages and is a lower cost alternative to keep the excellent HE performance at high luminosity. Measurements and simulations have been performed and this method is a good upgrade strategy.

  8. Management of complications relating to finger amputation and replantation.

    Science.gov (United States)

    Woo, Sang-Hyun; Kim, Young-Woo; Cheon, Ho-Jun; Nam, Hyun-Je; Kang, Dong-Ho; Kim, Jong-Min; Ahn, Hee-Chan

    2015-05-01

    There are many options in the management of fingertip or finger amputations. Injudicious revision amputation may cause complications. These complications can be prevented by tension-free closure of the amputation stump or primary coverage with appropriate flap. Replantation is the best way to keep the original length and maintain digital function. Patent vein repair or venous drainage with bleeding until neovascularization to the replanted part is the key to successful replantation. Prevention and management of complications in replantation and revision amputation increase patients' satisfaction and decrease costs. Research is needed to define new indications of replantation for digital amputation. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Viscous fingering and channeling in chemical enhanced oil recovery

    Science.gov (United States)

    Daripa, Prabir; Dutta, Sourav

    2017-11-01

    We have developed a hybrid numerical method based on discontinuous finite element method and modified method of characteristics to compute the multiphase multicomponent fluid flow in porous media in the context of chemical enhanced oil recovery. We use this method to study the effect of various chemical components on the viscous fingering and channeling in rectilinear and radial flow configurations. We will also discuss about the efficiency of various flooding schemes based on these understandings. Time permitting, we will discuss about the effect of variable injection rates in these practical setting. U.S. National Science Foundation Grant DMS-1522782.

  10. Kinematic analysis of the finger exoskeleton using MATLAB/Simulink.

    Science.gov (United States)

    Nasiłowski, Krzysztof; Awrejcewicz, Jan; Lewandowski, Donat

    2014-01-01

    A paralyzed and not fully functional part of human body can be supported by the properly designed exoskeleton system with motoric abilities. It can help in rehabilitation, or movement of a disabled/paralyzed limb. Both suitably selected geometry and specialized software are studied applying the MATLAB environment. A finger exoskeleton was the base for MATLAB/Simulink model. Specialized software, such as MATLAB/Simulink give us an opportunity to optimize calculation reaching precise results, which help in next steps of design process. The calculations carried out yield information regarding movement relation between three functionally connected actuators and showed distance and velocity changes during the whole simulation time.

  11. Review of Finger millet (Eleusine coracana (L.) Gaertn): A power house of health benefiting nutrients

    OpenAIRE

    Dinesh Chandra; Satish Chandra; Pallavi; A.K. Sharma

    2016-01-01

    The bulk of the world's millet crop is produced by India, Nigeria, Niger, Mali, Burkina Faso, Chad, and China. Finger millet (Eleusine coracana (L.) Gaertn), little millet (Panicum sumatrense Roth ex Roem. & Schult.), foxtail millet (Setaria italica (L.) P. Beauvois) and proso millet (Panicum miliaceum L.) are most commonly found species among various millet varieties. In India, finger millet occupy the largest area under cultivation among the small millets. Finger millet stands unique among ...

  12. Effect of Ethanol on Germination and Enzyme Activities in Finger millet (Eleusine coracana Gaertn.) Seeds

    OpenAIRE

    S.S. Kulkarni; P.D. Chavan

    2014-01-01

    Influence of ethanol the end product of alcoholic fermentation on the growth of finger millet (var. GPU-28, CO-9) seedlings of two finger millet was studied as a means of evaluating growth responses under anoxia. The germination was delayed by ethanol treatment in case of both the cultivars. Ethanol treatment affected the growth of both radicle and coleoptile of seedlings. In this respect the radicle growth is more sensitive to ethanol than the coleoptile in both varieties of finger millet. T...

  13. Evaluation of nutraceutical and antinutritional properties in barnyard and finger millet varieties grown in Himalayan region

    OpenAIRE

    Panwar, Priyankar; Dubey, Ashutosh; Verma, A. K.

    2016-01-01

    Five elite varieties of barnyard (Echinochloafrumentacea) and finger (Eleusine coracana) growing at northwestern Himalaya were investigated for nutraceutical and antinutritional properties. Barnyard millet contained higher amount of crude fiber, total dietary fiber, tryptophan content, total carotenoids, ��-tocopherol compared to the finger millet whereas the finger millet contains higher amount of methionine and ascorbic acid as compared to the barnyard millet. The secondary metabolites of b...

  14. Method of Grasping Control by Computing Internal and External Impedances for Two Robot Fingers, and Its Application to Admittance Control of a Robot Hand-Arm System

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2015-08-01

    Full Text Available Impedance control is an important technology used in the grasping control of a robot hand. Numerous studies related to grasping algorithms have been reported in recent years, with the contact force between robot fingers and the object to be grasped being primarily discussed in most cases. Generally, a coupling effect occurs between the internal loop of the grasping operation and the external loop of the interaction with the environment when a multi-fingered robot hand is used to complete a contact task. Therefore, a robot hand cannot hold an object using a large external force to complete a wide range of tasks by applying the conventional method. In this paper, the coupling of the internal/external forces occurring in grasping operations using multiple fingers is analysed. Then, improved impedance control based on the previous method is proposed as an effective tool to solve the problem of grasping failure caused by single-finger contact. Furthermore, a method for applying the improved grasping algorithm to the admittance control of a robot hand-arm system is also proposed. The proposed method divides the impedance effect into the grasping control of the hand and the cooperative control of the arm, so that expanding the task space and increasing the flexibility of impedance adjustment can be achieved. Experiments were conducted to demonstrate the effectiveness of the proposed method.

  15. Evaluation of nutraceutical and antinutritional properties in barnyard and finger millet varieties grown in Himalayan region.

    Science.gov (United States)

    Panwar, Priyankar; Dubey, Ashutosh; Verma, A K

    2016-06-01

    Five elite varieties of barnyard (Echinochloa frumentacea) and finger (Eleusine coracana) growing at northwestern Himalaya were investigated for nutraceutical and antinutritional properties. Barnyard millet contained higher amount of crude fiber, total dietary fiber, tryptophan content, total carotenoids, α-tocopherol compared to the finger millet whereas the finger millet contains higher amount of methionine and ascorbic acid as compared to the barnyard millet. The secondary metabolites of biological functions were analyzed and found that barnyard millet contained the higher amount of polyphenols, tannins and ortho-dihydroxy phenol content compared to finger millet. Among antinutitional compounds barnyard millet contained lower phytic acid content compare to finger millet whereas no significant difference in trypsin inhibition activity of barnyard millet and finger millet varieties were found. Barnyard millet contained higher acid phosphatase, α-galactosidase and α-amylase inhibitor activity compared to finger millet. Finger millet seeds contained about 10-13 folds higher calcium content and double amount of manganese content in comparison to barnyard millet seeds. Present study suggests that barnyard millet varieties studied under present investigation were found nutritionally superior compared to finger millet varieties.

  16. Evaluation of finger millet incorporated noodles for nutritive value and glycemic index.

    Science.gov (United States)

    Shukla, Kamini; Srivastava, Sarita

    2014-03-01

    The present study was undertaken to develop finger millet incorporated noodles for diabetic patients. Finger millet variety VL-149 was taken. The finger millet flour and refined wheat flour (RWF) were evaluated for nutrient composition. The finger millet flour (FMF) was blended in various proportions (30 to 50%) in refined wheat flour and used for the preparation of noodles. Control consisted of RWF noodles. Sensory quality and nutrient composition of finger millet noodles was evaluated. The 30% finger millet incorporated noodles were selected best on the basis of sensory evaluation. Noodles in that proportion along with control were evaluated for glycemic response. Nutrient composition of noodles showed that 50% finger millet incorporated noodles contained highest amount of crude fat (1.15%), total ash (1.40%), crude fiber (1.28%), carbohydrate (78.54%), physiological energy (351.36 kcal), insoluble dietary fiber (5.45%), soluble dietary fiber (3.71%), iron (5.58%) and calcium (88.39%), respectively. However, control RWF noodles contained highest amount of starch (63.02%), amylose (8.72%) and amylopectin (54.29%). The glycemic index (GI) of 30% finger millet incorporated noodles (best selected by sensory evaluation) was observed significantly lower (45.13) than control noodles (62.59). It was found that finger millet flour incorporated noodles were found nutritious and showed hypoglycemic effect.

  17. Comparative analyses reveal high levels of conserved colinearity between the finger millet and rice genomes.

    Science.gov (United States)

    Srinivasachary; Dida, Mathews M; Gale, Mike D; Devos, Katrien M

    2007-08-01

    Finger millet is an allotetraploid (2n = 4x = 36) grass that belongs to the Chloridoideae subfamily. A comparative analysis has been carried out to determine the relationship of the finger millet genome with that of rice. Six of the nine finger millet homoeologous groups corresponded to a single rice chromosome each. Each of the remaining three finger millet groups were orthologous to two rice chromosomes, and in all the three cases one rice chromosome was inserted into the centromeric region of a second rice chromosome to give the finger millet chromosomal configuration. All observed rearrangements were, among the grasses, unique to finger millet and, possibly, the Chloridoideae subfamily. Gene orders between rice and finger millet were highly conserved, with rearrangements being limited largely to single marker transpositions and small putative inversions encompassing at most three markers. Only some 10% of markers mapped to non-syntenic positions in rice and finger millet and the majority of these were located in the distal 14% of chromosome arms, supporting a possible correlation between recombination and sequence evolution as has previously been observed in wheat. A comparison of the organization of finger millet, Panicoideae and Pooideae genomes relative to rice allowed us to infer putative ancestral chromosome configurations in the grasses.

  18. Radiation safety education reduces the incidence of adult fingers on neonatal chest radiographs

    International Nuclear Information System (INIS)

    Sahota, N; Burbridge, B E; Duncan, M D

    2014-01-01

    A previous audit revealed a high frequency of adult fingers visualised on neonatal intensive care unit (NICU) chest radiographs—representing an example of inappropriate occupational radiation exposure. Radiation safety education was provided to staff and we hypothesised that the education would reduce the frequency of adult fingers visualised on NICU chest radiographs. Two cross-sectional samples taken before and after the administration of the education were compared. We examined fingers visualised directly in the beam, fingers in the direct beam but eliminated by technologists editing the image, and fingers under the cones of the portable x-ray machine. There was a 46.2% reduction in fingers directly in the beam, 50.0% reduction in fingers directly in the beam but cropped out, and 68.4% reduction in fingers in the coned area. There was a 57.1% overall reduction in adult fingers visualised, which was statistically significant (Z value − 7.48, P < 0.0001). This study supports radiation safety education in minimising inappropriate occupational radiation exposure. (paper)

  19. Normal tendon sheath of the second to fifth fingers as seen on oblique views

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis.

  20. Effects of finger counting on numerical development – the opposing views of neurocognition and mathematics education

    Directory of Open Access Journals (Sweden)

    Korbinian eMoeller

    2011-11-01

    Full Text Available Usually children learn the basic principles of number and arithmetic by the help of finger-based representations. However, whether the reliance on finger-based representations is only beneficial or whether it may even become detrimental is the subject of an ongoing debate between neuro-cognitive and mathematics education researchers. From the neuro-cognitive perspective finger counting provides multi-sensory input conveying both cardinal and ordinal aspects of numbers. Recent data indicate that children with good finger-based numerical representations show better arithmetic skills and that training finger gnosis enhances mathematical skills. From this neuro-cognitive researchers conclude that elaborate finger-based numerical representations are beneficial for later numerical development.However, mathematics education research recommends fostering mental numerical representations so as to induce children to abandon finger-counting. More precisely mathematics education recommends moving from finger counting to concrete structured representations and then, finally, to mental representations of numbers.Taken together, there is obviously an important debate between the neuro-cognitve and mathematics education research concerning the benefits or detriments of finger-based strategies for numerical development. In the present review, the rationale of both lines of evidence will be presented and discussed.

  1. Dynamic performance of a C/C composite finger seal in a tilting mode

    Directory of Open Access Journals (Sweden)

    Hailin ZHAO

    2017-08-01

    Full Text Available The complex operating state of aeroengines has an impact on the performance of finger seals. However, little work has been focused on the issue and the dynamic performance of finger seals is also rarely studied. Therefore, a distributed mass equivalent model considering working conditions is proposed in this paper for solving the existing problems. The effects of the fiber bundle density and the preparation direction of the fiber bundle of a C/C composite on the dynamic performance of a finger seal are investigated in rotor tilt based on the proposed model. The difference between the C/C composite finger seal performances under the rotor precession and nutation tilt cases is also investigated. The results show that the fiber bundle density and the preparation direction of the fiber bundle have an influence on the dynamic performance of the finger seal as rotor tilt is considered, and the dynamic performance of the finger seal is different in the two kinds of tilting modes. In addition, a novel method for design of finger seals is presented based on the contact pressure between finger boots and the rotor. Finger seals with good leakage rates and low wear can be acquired in this method.

  2. Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Tobias Blumenstein

    2015-01-01

    Full Text Available Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings.

  3. A microelectrostatic repulsive-torque rotation actuator with two-width fingers

    International Nuclear Information System (INIS)

    Fan, Chao; He, Siyuan

    2015-01-01

    A microelectrostatic repulsive-torque rotation actuator with two-width fingers is presented. The actuator consists of finger-shaped electrodes and is made of two thin film layers, i.e. one movable layer and one fixed layer. There are two types of finger electrodes, namely constant-width and two-width fingers. The two-width finger has a narrow lower segment and a wide top segment. The constant-width finger has only the narrow lower segment. Each rotation finger has its corresponding aligned and unaligned fixed fingers. The electrostatic repulsive torque is generated and acts on the rotation fingers to rotate them up and away from the substrate. As a result, rotation is not limited by the gap between the movable and fixed layers and the ‘pull-in’ instability is avoided. Thus a large out-of-plane rotation and high operational stability can be achieved. The actuator is suitable for two-layer surface micromachining. The model of the actuator is developed. Prototypes are fabricated and tested. The experimental tests show that the actuator achieved a mechanical rotation of 7.65° at a driving voltage of 150 V. The settling time for a mechanical rotation of 5° is 5.7 ms. (paper)

  4. The Physiological Molecular Shape of Spectrin: A Compact Supercoil Resembling a Chinese Finger Trap.

    Science.gov (United States)

    Brown, Jeffrey W; Bullitt, Esther; Sriswasdi, Sira; Harper, Sandra; Speicher, David W; McKnight, C James

    2015-06-01

    The primary, secondary, and tertiary structures of spectrin are reasonably well defined, but the structural basis for the known dramatic molecular shape change, whereby the molecular length can increase three-fold, is not understood. In this study, we combine previously reported biochemical and high-resolution crystallographic data with structural mass spectroscopy and electron microscopic data to derive a detailed, experimentally-supported quaternary structure of the spectrin heterotetramer. In addition to explaining spectrin's physiological resting length of ~55-65 nm, our model provides a mechanism by which spectrin is able to undergo a seamless three-fold extension while remaining a linear filament, an experimentally observed property. According to the proposed model, spectrin's quaternary structure and mechanism of extension is similar to a Chinese Finger Trap: at shorter molecular lengths spectrin is a hollow cylinder that extends by increasing the pitch of each spectrin repeat, which decreases the internal diameter. We validated our model with electron microscopy, which demonstrated that, as predicted, spectrin is hollow at its biological resting length of ~55-65 nm. The model is further supported by zero-length chemical crosslink data indicative of an approximately 90 degree bend between adjacent spectrin repeats. The domain-domain interactions in our model are entirely consistent with those present in the prototypical linear antiparallel heterotetramer as well as recently reported inter-strand chemical crosslinks. The model is consistent with all known physical properties of spectrin, and upon full extension our Chinese Finger Trap Model reduces to the ~180-200 nm molecular model currently in common use.

  5. The Physiological Molecular Shape of Spectrin: A Compact Supercoil Resembling a Chinese Finger Trap.

    Directory of Open Access Journals (Sweden)

    Jeffrey W Brown

    2015-06-01

    Full Text Available The primary, secondary, and tertiary structures of spectrin are reasonably well defined, but the structural basis for the known dramatic molecular shape change, whereby the molecular length can increase three-fold, is not understood. In this study, we combine previously reported biochemical and high-resolution crystallographic data with structural mass spectroscopy and electron microscopic data to derive a detailed, experimentally-supported quaternary structure of the spectrin heterotetramer. In addition to explaining spectrin's physiological resting length of ~55-65 nm, our model provides a mechanism by which spectrin is able to undergo a seamless three-fold extension while remaining a linear filament, an experimentally observed property. According to the proposed model, spectrin's quaternary structure and mechanism of extension is similar to a Chinese Finger Trap: at shorter molecular lengths spectrin is a hollow cylinder that extends by increasing the pitch of each spectrin repeat, which decreases the internal diameter. We validated our model with electron microscopy, which demonstrated that, as predicted, spectrin is hollow at its biological resting length of ~55-65 nm. The model is further supported by zero-length chemical crosslink data indicative of an approximately 90 degree bend between adjacent spectrin repeats. The domain-domain interactions in our model are entirely consistent with those present in the prototypical linear antiparallel heterotetramer as well as recently reported inter-strand chemical crosslinks. The model is consistent with all known physical properties of spectrin, and upon full extension our Chinese Finger Trap Model reduces to the ~180-200 nm molecular model currently in common use.

  6. Frequency spectrum analysis of finger photoplethysmographic waveform variability during haemodialysis.

    Science.gov (United States)

    Javed, Faizan; Middleton, Paul M; Malouf, Philip; Chan, Gregory S H; Savkin, Andrey V; Lovell, Nigel H; Steel, Elizabeth; Mackie, James

    2010-09-01

    This study investigates the peripheral circulatory and autonomic response to volume withdrawal in haemodialysis based on spectral analysis of photoplethysmographic waveform variability (PPGV). Frequency spectrum analysis was performed on the baseline and pulse amplitude variabilities of the finger infrared photoplethysmographic (PPG) waveform and on heart rate variability extracted from the ECG signal collected from 18 kidney failure patients undergoing haemodialysis. Spectral powers were calculated from the low frequency (LF, 0.04-0.145 Hz) and high frequency (HF, 0.145-0.45 Hz) bands. In eight stable fluid overloaded patients (fluid removal of >2 L) not on alpha blockers, progressive reduction in relative blood volume during haemodialysis resulted in significant increase in LF and HF powers of PPG baseline and amplitude variability (P analysis of finger PPGV may provide valuable information on the autonomic vascular response to blood volume reduction in haemodialysis, and can be potentially utilized as a non-invasive tool for assessing peripheral circulatory control during routine dialysis procedure.

  7. Evaluation of interobserver agreement in Albertoni's classification for mallet finger

    Directory of Open Access Journals (Sweden)

    Vinícius Alexandre de Souza Almeida

    Full Text Available ABSTRACT Objective: To measure the reliability of Albertoni's classification for mallet finger. Methods: Agreement study. Forty-three radiographs of patients with mallet finger were assessed by 19 responders (12 hand surgeons and seven residents. Injuries were classified by Albertoni's classification. For agreement comparison, lesions were grouped as: (A tendon avulsion; (B avulsion fracture; (C fracture of the dorsal lip; and (D physis injury-and subgroups (each group divided into two subgroups. Agreement was assessed by Fleiss's modification for kappa statistics. Results: Agreement was excellent for Group A (k = 0.95 (0.93-0.97 and remained good when separated into A1 and A2. Group B was moderate (k = 0.42 (0.39-0.44 and poor when separated into B1 and B2. In the Group C, agreement was good (k = 0.72 (0.70-0.74, but when separated into C1 and C2, it became moderate. Group D was always poor (k = 0.16 (0.14-0.19. The general agreement was moderate, with (k = 0.57 (0.56-0.58. Conclusion: Albertoni's classification evaluated for interobserver agreement is considered a reproducible classification by the method used in the research.

  8. Unveiling the Biometric Potential of Finger-Based ECG Signals

    Science.gov (United States)

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications. PMID:21837235

  9. EFEKTIFITAS PELAKSANAAN FINGER PRINT DI IAIN RADEN FATAH PALEMBANG

    Directory of Open Access Journals (Sweden)

    Syahir Badruddin

    2015-07-01

    Full Text Available Recently, discipline becomes an important thing that becomes the focus of attention in almost all organizations. Some studies even linking discipline with performance that if the level of discipline members of the organization better then the performance will increase. IAIN Raden Fatah Palembang as one of the organizations also see discipline as an important factor that must be considered by all employees and lecturers mainly based on Government Regulation No. 30 1980 which was amended by Government Regulation No. 53 in 2010. Meanwhile, for the Ministry of Religion itself translated back through the Minister of Religion No. 28 in 2013 and again by Decree especially Rector IAIN Raden Fatah regulating the working hours of employees and lecturers. To obtain a report of presence accountable, it is used in the finger print machine IAIN Raden Fatah Palembang. To see the effectiveness of the implementation of these activities, we conducted observations, interviews and documentation as a means of collecting data. And, the resulting data will be analyzed qualitatively and elaborated descriptively. After the stages of research, showed that the application of the rules the government has been running well and supported by adequate facilities. However, not maximal processing, synchronization data and application of punishment and reward led to a lack of effective use of finger prints on the existing units in IAIN Raden Fatah Palembang.

  10. Evolution of finger millet: evidence from random amplified polymorphic DNA.

    Science.gov (United States)

    Hilu, K W

    1995-04-01

    Finger millet (Eleusine coracana ssp. coracana) is an annual tetraploid member of a predominantly African genus. The crop is believed to have been domesticated from the tetraploid E. coracana ssp. africana. Cytogenetic and isozyme data point to the allopolyploid nature of the species and molecular information has shown E. indica to be one of the genomic donors. A recent isozyme study questioned the proposed phylogenetic relationship between finger millet and its direct ancestor subspecies africana. An approach using random amplified polymorphic DNA (RAPD) was employed in this study to examine genetic diversity and to evaluate hypotheses concerning the evolution of domesticated and wild annual species of Eleusine. Unlike previous molecular approaches, the RAPD study revealed genetic diversity in the crop. The pattern of genetic variation was loosely correlated to geographic distribution. The allotetraploid nature of the crop was confirmed and molecular markers that can possibly identify the other genomic donor were proposed. Genotypes of subspecies africana did not group closely with those of the crop but showed higher affinities to E. indica, reflecting the pattern of similarity revealed by the isozyme study. The multiple origin of subspecies africana could explain the discrepancy between the isozyme-RAPD evidence and previous information. The RAPD study showed the close genetic affinity of E. tristachya to the E. coracana--E. indica group and understood the distinctness of E. multiflora.

  11. Habitual biting of a finger in a child

    Directory of Open Access Journals (Sweden)

    K N Sarveswari

    2017-01-01

    Full Text Available A 3-year-old male child was brought by his parents with a nonhealing ulcer on the right middle finger having no significant history except for an injury sustained to the right elbow in December 2013. On further probing, the mother revealed that the child used to indulge in habitual biting of his right middle finger while watching TV. Initially he was investigated extensively by a vascular surgeon and no abnormality was detected. He was later referred to the dermatology department and on examination, the patient was attentive with normal behaviour. The right upper limb was slightly larger than left. There was no deformity of the right elbow. The right third fingertip was enlarged and mutilated. There was no nerve thickening or hypopigmented patch. There was loss of sensation on the right hand and arm. Differential diagnosis of Lesch–Nyhan syndrome and congenital sensory neuropathy were considered. The patient was referred to a neurologist who investigated further with magnetic resonance imaging (MRI, and the final diagnosis of syringomyelia was made based on MRI findings.

  12. Research and implementation of finger-vein recognition algorithm

    Science.gov (United States)

    Pang, Zengyao; Yang, Jie; Chen, Yilei; Liu, Yin

    2017-06-01

    In finger vein image preprocessing, finger angle correction and ROI extraction are important parts of the system. In this paper, we propose an angle correction algorithm based on the centroid of the vein image, and extract the ROI region according to the bidirectional gray projection method. Inspired by the fact that features in those vein areas have similar appearance as valleys, a novel method was proposed to extract center and width of palm vein based on multi-directional gradients, which is easy-computing, quick and stable. On this basis, an encoding method was designed to determine the gray value distribution of texture image. This algorithm could effectively overcome the edge of the texture extraction error. Finally, the system was equipped with higher robustness and recognition accuracy by utilizing fuzzy threshold determination and global gray value matching algorithm. Experimental results on pairs of matched palm images show that, the proposed method has a EER with 3.21% extracts features at the speed of 27ms per image. It can be concluded that the proposed algorithm has obvious advantages in grain extraction efficiency, matching accuracy and algorithm efficiency.

  13. Unveiling the biometric potential of finger-based ECG signals.

    Science.gov (United States)

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.

  14. Krüppel-like factors: Three fingers in control

    Directory of Open Access Journals (Sweden)

    Swamynathan Shivalingappa K

    2010-04-01

    Full Text Available Abstract Krüppel-like factors (KLFs, members of the zinc-finger family of transcription factors capable of binding GC-rich sequences, have emerged as critical regulators of important functions all over the body. They are characterised by a highly conserved C-terminal DNA-binding motif containing three C2H2 zinc-finger domains, with variable N-terminal regulatory domains. Currently, there are 17 KLFs annotated in the human genome. In spite of their structural similarity to one another, the genes encoding different KLFs are scattered all over the genome. By virtue of their ability to activate and/or repress the expression of a large number of genes, KLFs regulate a diverse array of developmental events and cellular processes, such as erythropoiesis, cardiac remodelling, adipogenesis, maintenance of stem cells, epithelial barrier formation, control of cell proliferation and neoplasia, flow-mediated endothelial gene expression, skeletal and smooth muscle development, gluconeogenesis, monocyte activation, intestinal and conjunctival goblet cell development, retinal neuronal regeneration and neonatal lung development. Characteristic features, nomenclature, evolution and functional diversities of the human KLFs are reviewed here.

  15. Krüppel-like factors: three fingers in control.

    Science.gov (United States)

    Swamynathan, Shivalingappa K

    2010-04-01

    Krüppel-like factors (KLFs), members of the zinc-finger family of transcription factors capable of binding GC-rich sequences, have emerged as critical regulators of important functions all over the body. They are characterised by a highly conserved C-terminal DNA-binding motif containing three C2H2 zinc-finger domains, with variable N-terminal regulatory domains. Currently, there are 17 KLFs annotated in the human genome. In spite of their structural similarity to one another, the genes encoding different KLFs are scattered all over the genome. By virtue of their ability to activate and/or repress the expression of a large number of genes, KLFs regulate a diverse array of developmental events and cellular processes, such as erythropoiesis, cardiac remodelling, adipogenesis, maintenance of stem cells, epithelial barrier formation, control of cell proliferation and neoplasia, flow-mediated endothelial gene expression, skeletal and smooth muscle development, gluconeogenesis, monocyte activation, intestinal and conjunctival goblet cell development, retinal neuronal regeneration and neonatal lung development. Characteristic features, nomenclature, evolution and functional diversities of the human KLFs are reviewed here.

  16. Timing and extent of finger force enslaving during a dynamic force task cannot be explained by EMG activity patterns.

    Directory of Open Access Journals (Sweden)

    Mojtaba Mirakhorlo

    Full Text Available Finger enslaving is defined as the inability of the fingers to move or to produce force independently. Such finger enslaving has predominantly been investigated for isometric force tasks. The aim of this study was to assess whether the extent of force enslaving is dependent on relative finger movements. Ten right-handed subjects (22-30 years flexed the index finger while counteracting constant resistance forces (4, 6 and 8 N orthogonal to the fingertip. The other, non-instructed fingers were held in extension. EMG activities of the mm. flexor digitorum superficialis (FDS and extensor digitorum (ED in the regions corresponding to the index, middle and ring fingers were measured. Forces exerted by the non-instructed fingers increased substantially (by 0.2 to 1.4 N with flexion of the index finger, increasing the enslaving effect with respect to the static, pre-movement phase. Such changes in force were found 260-370 ms after the initiation of index flexion. The estimated MCP joint angle of the index finger at which forces exerted by the non-instructed fingers started to increase varied between 4° and 6°. In contrast to the finger forces, no significant changes in EMG activity of the FDS regions corresponding to the non-instructed fingers upon index finger flexion were found. This mismatch between forces and EMG of the non-instructed fingers, as well as the delay in force development are in agreement with connective tissue linkages being slack when the positions of the fingers are similar, but pulled taut when one finger moves relative to the others. Although neural factors cannot be excluded, our results suggest that mechanical connections between muscle-tendon structures were (at least partly responsible for the observed increase in force enslaving during index finger flexion.

  17. Three-dimensional viscous fingering of miscible fluids in porous media

    Science.gov (United States)

    Suekane, Tetsuya; Ono, Jei; Hyodo, Akimitsu; Nagatsu, Yuichiro

    2017-10-01

    Viscous fingering is a flow instability that is induced at the displacement front when a less-viscous fluid (LVF) displaces a more-viscous fluid (MVF). Because of the opaque nature of porous media, most experimental investigations of the structure of viscous fingering and its development in time have been limited to two-dimensional porous media or Hele-Shaw cells. In this study, we investigate the three-dimensional characteristics of viscous fingering in porous media using a microfocused x-ray computer tomography (CT) scanner. Similar to two-dimensional experiments, characteristic events such as tip-splitting, shielding, and coalescence were observed in three-dimensional viscous fingering as well. With an increase in the Péclet number at a fixed viscosity ratio, M , the fingers appearing on the interface tend to be fine; however, the locations of the tips of the fingers remain the same for the same injected volume of the LVF. The finger extensions increase in proportion to ln M , and the number of fingers emerging at the initial interface increases with M . This fact agrees qualitatively with linear stability analyses. Within the fingers, the local concentration of NaI, which is needed for the x-ray CT scanner, linearly decreases, whereas it sharply decreases at the tips of the fingers. A locally high Péclet number as well as unsteady motions in lateral directions may enhance the dispersion at the tips of the fingers. As the viscosity ratio increases, the efficiency of each sweep monotonically decreases and reaches an asymptotic state; in addition, the degree of mixing increases with the viscosity ratio. For high flow rates, the asymptotic value of the sweep efficiency is low for high viscosity ratios, while there is no clear dependence of the asymptotic value on the Péclet number.

  18. A new technique to determine vertical dimension of occlusion from anthropometric measurements of fingers

    Directory of Open Access Journals (Sweden)

    Ruchi Ladda

    2013-01-01

    Full Text Available Purpose: The purpose of this study was to find the correlation between vertical dimension of occlusion (VDO and length of fingers. Materials and Methods: A cross-sectional study was conducted on 400 dentate subjects comprising of 200 males and 200 females. Anthropometric measurements of VDO, length of index finger, length of little finger, and distance from tip of thumb to tip of index finger of right hand were recorded clinically using modified digital vernier caliper. Correlation between VDO and length of fingers was studied using Spearman′s coefficient. For the execution of regression command and preparation of prediction equations to estimate VDO, Statistical Package for Social Sciences Software Version 11.5 was used. Results: VDO was significantly and positively correlated with all the parameters studied. In males, correlation of VDO was strongest for length of index finger (r-0.406 whereas in females, it was strongest for length of little finger (r-0.385. VDO estimation using regression equation had a standard error of ± 3.76 in males and ± 2.86 in females for length of index finger, ±3.81 and ± 2.74 in males and females respectively for length of little finger, ±3.99 and ± 2.89 in males and females respectively for distance from tip of thumb to tip of index finger. Conclusions: Since the variations between VDO and finger lengths are within the range of 2-4 mm, VDO prediction through this method is reliable, and reproducible. Also the method is simple, economic, and non-invasive; hence, it could be recommended for everyday practice.

  19. On the relationship between finger width, velocity, and fluxes in thermohaline convection

    Science.gov (United States)

    Sreenivas, K. R.; Singh, O. P.; Srinivasan, J.

    2009-02-01

    Double-diffusive finger convection occurs in many natural processes. The theories for double-diffusive phenomena that exist at present consider systems with linear stratification in temperature and salinity. The double-diffusive systems with step change in salinity and temperature are, however, not amenable to simple stability analysis. Hence factors that control the width of the finger, velocity, and fluxes in systems that have step change in temperature and salinity have not been understood so far. In this paper we provide new physical insight regarding factors that influence finger convection in two-layer double-diffusive system through two-dimensional numerical simulations. Simulations have been carried out for density stability ratios (Rρ) from 1.5 to 10. For each density stability ratio, the thermal Rayleigh number (RaT) has been systematically varied from 7×103 to 7×108. Results from these simulations show how finger width, velocity, and flux ratios in finger convection are interrelated and the influence of governing parameters such as density stability ratio and the thermal Rayleigh number. The width of the incipient fingers at the time of onset of instability has been shown to vary as RaT-1/3. Velocity in the finger varies as RaT1/3/Rρ. Results from simulation agree with the scale analysis presented in the paper. Our results demonstrate that wide fingers have lower velocities and flux ratios compared to those in narrow fingers. This result contradicts present notions about the relation between finger width and flux ratio. A counterflow heat-exchanger analogy is used in understanding the dependence of flux ratio on finger width and velocity.

  20. An fMRI study during finger movement tasks and recalling finger movement tasks in normal subjects and schizophrenia patients

    International Nuclear Information System (INIS)

    Ueno, Takefumi

    2003-01-01

    Using fMRI, we investigated the region of the brain, which was activated by the finger movement tasks (F1) and the recalling finger movement tasks (F2). Six right-handed age-matched healthy controls and six Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV) Schizophrenia patients were included in the study. In healthy controls, contralateral motor area, supplementary motor area and somatosensory area were all activated during F1 and F2. However the contralateral parietal lobe (supramarginal gyrus etc) and ipsilateral cerebellum were also activated during F2. In schizophrenia patients, the contralateral motor area was activated during F1, but the activated region was smaller than that observed in healthy subjects. During F2, the bilateral parietal lobes (sensorimotor cortices, association cortex) were activated, while the activated regions were smaller than those seen in healthy controls and no laterality was observed. In addition, no laterality of the activated regions was clearly observed. These results suggest that the function of recalling motor tasks can be mapped onto the contralateral motor area, somatosensory area, supplementary motor area, parietal association cortices, and ipsilateral cerebellum. In schizophrenia patients, the activated regions are smaller than those observed in healthy controls, and parietal regions are also activated bilaterally during recalling motor tasks. Schizophrenia patients may therefore process to recall motor task differently from healthy subjects while also demonstrate less laterality of the brain. (author)

  1. Role of protein structure and the role of individual fingers in zinc finger protein-DNA recognition: a molecular dynamics simulation study and free energy calculations

    Science.gov (United States)

    Hamed, Mazen Y.

    2018-05-01

    Molecular dynamics and MM_GBSA energy calculations on various zinc finger proteins containing three and four fingers bound to their target DNA gave insights into the role of each finger in the DNA binding process as part of the protein structure. The wild type Zif 268 (PDB code: 1AAY) gave a ΔG value of - 76.1 (14) kcal/mol. Zinc fingers ZF1, ZF2 and ZF3 were mutated in one experiment and in another experiment one finger was cut and the rest of the protein was studied for binding. The ΔΔG values for the Zinc Finger protein with both ZF1 and ZF2 mutated was + 80 kcal/mol, while mutating only ZF1 the ΔΔG value was + 52 kcal/mol (relative to the wild type). Cutting ZF3 and studying the protein consisting only of ZF1 linked to ZF2 gave a ΔΔG value of + 68 kcal/mol. Upon cutting ZF1, the resulting ZF2 linked to ZF3 protein gave a ΔΔG value of + 41 kcal/mol. The above results shed light on the importance of each finger in the binding process, especially the role of ZF1 as the anchoring finger followed in importance by ZF2 and ZF3. The energy difference between the binding of the wild type protein Zif268 (1AAY) and that for individual finger binding to DNA according to the formula: ΔΔGlinkers, otherstructuralfactors = ΔGzif268 - (ΔGF1+F2+F3) gave a value = - 44.5 kcal/mol. This stabilization can be attributed to the contribution of linkers and other structural factors in the intact protein in the DNA binding process. DNA binding energies of variant proteins of the wild type Zif268 which differ in their ZF1 amino acid sequence gave evidence of a good relationship between binding energy and recognition and specificity, this finding confirms the reported vital role of ZF1 in the ZF protein scanning and anchoring to the target DNA sequence. The role of hydrogen bonds in both specific and nonspecific amino acid-DNA contacts is discussed in relation to mutations. The binding energies of variant Zinc Finger proteins confirmed the role of ZF1 in the recognition

  2. Structural and functional characterization of a novel homodimeric three-finger neurotoxin from the venom of Ophiophagus hannah (king cobra).

    Science.gov (United States)

    Roy, Amrita; Zhou, Xingding; Chong, Ming Zhi; D'hoedt, Dieter; Foo, Chun Shin; Rajagopalan, Nandhakishore; Nirthanan, Selvanayagam; Bertrand, Daniel; Sivaraman, J; Kini, R Manjunatha

    2010-03-12

    Snake venoms are a mixture of pharmacologically active proteins and polypeptides that have led to the development of molecular probes and therapeutic agents. Here, we describe the structural and functional characterization of a novel neurotoxin, haditoxin, from the venom of Ophiophagus hannah (King cobra). Haditoxin exhibited novel pharmacology with antagonism toward muscle (alphabetagammadelta) and neuronal (alpha(7), alpha(3)beta(2), and alpha(4)beta(2)) nicotinic acetylcholine receptors (nAChRs) with highest affinity for alpha(7)-nAChRs. The high resolution (1.5 A) crystal structure revealed haditoxin to be a homodimer, like kappa-neurotoxins, which target neuronal alpha(3)beta(2)- and alpha(4)beta(2)-nAChRs. Interestingly however, the monomeric subunits of haditoxin were composed of a three-finger protein fold typical of curaremimetic short-chain alpha-neurotoxins. Biochemical studies confirmed that it existed as a non-covalent dimer species in solution. Its structural similarity to short-chain alpha-neurotoxins and kappa-neurotoxins notwithstanding, haditoxin exhibited unique blockade of alpha(7)-nAChRs (IC(50) 180 nm), which is recognized by neither short-chain alpha-neurotoxins nor kappa-neurotoxins. This is the first report of a dimeric short-chain alpha-neurotoxin interacting with neuronal alpha(7)-nAChRs as well as the first homodimeric three-finger toxin to interact with muscle nAChRs.

  3. Neuron selection based on deflection coefficient maximization for the neural decoding of dexterous finger movements.

    Science.gov (United States)

    Kim, Yong-Hee; Thakor, Nitish V; Schieber, Marc H; Kim, Hyoung-Nam

    2015-05-01

    Future generations of brain-machine interface (BMI) will require more dexterous motion control such as hand and finger movements. Since a population of neurons in the primary motor cortex (M1) area is correlated with finger movements, neural activities recorded in M1 area are used to reconstruct an intended finger movement. In a BMI system, decoding discrete finger movements from a large number of input neurons does not guarantee a higher decoding accuracy in spite of the increase in computational burden. Hence, we hypothesize that selecting neurons important for coding dexterous flexion/extension of finger movements would improve the BMI performance. In this paper, two metrics are presented to quantitatively measure the importance of each neuron based on Bayes risk minimization and deflection coefficient maximization in a statistical decision problem. Since motor cortical neurons are active with movements of several different fingers, the proposed method is more suitable for a discrete decoding of flexion-extension finger movements than the previous methods for decoding reaching movements. In particular, the proposed metrics yielded high decoding accuracies across all subjects and also in the case of including six combined two-finger movements. While our data acquisition and analysis was done off-line and post processing, our results point to the significance of highly coding neurons in improving BMI performance.

  4. 16 CFR Figure 4 to Part 1610 - An Example of a Typical Indicator Finger

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false An Example of a Typical Indicator Finger 4 Figure 4 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Example of a Typical Indicator Finger ER25MR08.003 ...

  5. Women's finger sensitivity correlates with partnered sexual behavior but not solitary masturbation frequencies

    NARCIS (Netherlands)

    Brody, S.; Fischer, A.H.; Hess, U.

    2008-01-01

    In a sample of 97 healthy Dutch female university students, women with greater finger tactile sensitivity (von Frey-type filaments) engaged more in partnered (but not solitary masturbation) sexual behavior. Orgasmic responses in the past 30 days were not correlated with finger sensitivity. Results

  6. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    Science.gov (United States)

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  7. Finger Counting Habits in Middle Eastern and Western Individuals: An Online Survey

    NARCIS (Netherlands)

    Lindemann, O.; Alipour, A.; Fischer, M.H.

    2011-01-01

    The current study documents the presence of cultural differences in the development of finger counting strategies. About 900 Middle Eastern (i.e., Iranian) and Western (i.e., European and American) individuals reported in an online survey how they map numbers onto their fingers when counting from 1

  8. Finger jointing green southern yellow pine with a soy-based adhesive

    Science.gov (United States)

    Philip H. Steele; Roland E. Kreibicha; Petrus J. Steynberg; Richard W. Hemingway

    1998-01-01

    The authors present results of laboratory tests for a soy-based adhesive to bond southern yellow pine using the finger-jointing method. There was some reason to suspect that finger jointing of southern yellow pine (SYP) with the honeymoon system using soy-based adhesive might prove more difficult than for western species. The Wood Handbook classes western species in...

  9. Finger-tapping motion analysis in cervical myelopathy by magnetic-sensor tapping device.

    Science.gov (United States)

    Miwa, Toshitada; Hosono, Noboru; Mukai, Yoshihiro; Makino, Takahiro; Kandori, Akihiko; Fuji, Takeshi

    2013-08-01

    Case-control study. The purpose of this study is to determine finger motion of patients with cervical myelopathy during finger-tapping cycles. A major symptom of patients with compressive cervical myelopathy is finger clumsiness. Therefore, understanding finger motion is prerequisite in assessing the severity of myelopathy. The popular grip-and-release test evaluates only the number of motion cycles, which is insufficient to fully describe complex finger motion. Forty-three patients with cervical myelopathy and 41 healthy controls tapped their index fingers against their thumbs as rapidly as possible for 30 seconds and the motion was recorded by a magnetic-sensor coil attached to the nail surface. Output signals were stored in a computer, which automatically calculated tapping frequency, distance moved, ratio of opening/closing velocity and the SD of the tapping interval. The SD of the tapping interval was significantly greater and all other measures were significantly smaller in patients with cervical myelopathy, than in healthy controls. All indices significantly improved after surgical decompression of the cervical spine. Distance moved (Pearson correlation coefficient: r=0.590, Ptapping interval (r=-0.451; P=0.002) were significantly correlated with the Japanese Orthopedic Association score (neurological scale). The quantitative evaluation of finger paralysis was performed by this tapping device. Speed and regularity in repetitive motion of fingers were correlated with the severity of cervical myelopathy.

  10. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture

    Directory of Open Access Journals (Sweden)

    Rong-Jie Bai

    2018-01-01

    Conclusions: Sports injury-related fingers and thumb deformity are relatively common. MRI is an accurate method for evaluation of the anatomy and pathologic conditions of the fingers and thumb. It is a useful tool for accurate diagnosis of the sports-related ligaments and tendons injuries in hand.

  11. A high quality finger vascular pattern dataset collected using a custom designed capturing device

    NARCIS (Netherlands)

    Ton, B.T.; Veldhuis, Raymond N.J.

    2013-01-01

    The number of finger vascular pattern datasets available for the research community is scarce, therefore a new finger vascular pattern dataset containing 1440 images is prsented. This dataset is unique in its kind as the images are of high resolution and have a known pixel density. Furthermore this

  12. Gold finger formation studied by high-resolution mass spectrometry and in silico methods

    NARCIS (Netherlands)

    Laskay, Ü.A.; Garino, C.; Tsybin, Y.O.; Salassa, L.; Casini, A.

    2015-01-01

    High-resolution mass spectrometry and quantum mechanics/molecular mechanics studies were employed for characterizing the formation of two gold finger (GF) domains from the reaction of zinc fingers (ZF) with gold complexes. The influence of both the gold oxidation state and the ZF coordination sphere

  13. Models of brachial to finger pulse wave distortion and pressure decrement

    NARCIS (Netherlands)

    Gizdulich, P.; Prentza, A.; Wesseling, K.H.

    1997-01-01

    Objective: To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Methods: Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by

  14. Neural network committees for finger joint angle estimation from surface EMG signals

    Directory of Open Access Journals (Sweden)

    Reddy Narender P

    2009-01-01

    Full Text Available Abstract Background In virtual reality (VR systems, the user's finger and hand positions are sensed and used to control the virtual environments. Direct biocontrol of VR environments using surface electromyography (SEMG signals may be more synergistic and unconstraining to the user. The purpose of the present investigation was to develop a technique to predict the finger joint angle from the surface EMG measurements of the extensor muscle using neural network models. Methodology SEMG together with the actual joint angle measurements were obtained while the subject was performing flexion-extension rotation of the index finger at three speeds. Several neural networks were trained to predict the joint angle from the parameters extracted from the SEMG signals. The best networks were selected to form six committees. The neural network committees were evaluated using data from new subjects. Results There was hysteresis in the measured SMEG signals during the flexion-extension cycle. However, neural network committees were able to predict the joint angle with reasonable accuracy. RMS errors ranged from 0.085 ± 0.036 for fast speed finger-extension to 0.147 ± 0.026 for slow speed finger extension, and from 0.098 ± 0.023 for the fast speed finger flexion to 0.163 ± 0.054 for slow speed finger flexion. Conclusion Although hysteresis was observed in the measured SEMG signals, the committees of neural networks were able to predict the finger joint angle from SEMG signals.

  15. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  16. The Power of a Soccer Ball: A Traumatic Open Finger Dislocation—A Rare Case Presentation

    Directory of Open Access Journals (Sweden)

    Turan Cihan Dülgeroğlu

    2015-01-01

    Full Text Available Proximal interphalangeal joint dislocations are injuries observed frequently and caused by axial loading on the finger in the extension. In this paper we present a traumatic open finger dislocation due to a ball hitting a wrestler. It was successfully treated with reduction and the volar plate and collateral bond fixation were applied with absorbable sutures.

  17. Self-Expression or Teacher Influence: The Shaw System of Finger-Painting.

    Science.gov (United States)

    Stankiewicz, Mary Ann

    1984-01-01

    Finger painting is often regarded as the epitome of free expression for children. However, a careful review of the history of Ruth Shaw's finger-painting system reveals that it was dominated by specific techniques and stylistic conventions taught without a critical understanding of art history or appreciation. (IS)

  18. Birth Outcomes across Three Rural-Urban Typologies in the Finger Lakes Region of New York

    Science.gov (United States)

    Strutz, Kelly L.; Dozier, Ann M.; van Wijngaarden, Edwin; Glantz, J. Christopher

    2012-01-01

    Purpose: The study is a descriptive, population-based analysis of birth outcomes in the New York State Finger Lakes region designed to determine whether perinatal outcomes differed across 3 rural typologies. Methods: Hospital birth data for the Finger Lakes region from 2006 to 2007 were used to identify births classified as low birthweight (LBW),…

  19. Design and control of three fingers motion for dexterous assembly of ...

    African Journals Online (AJOL)

    In this paper, the authors describe and demonstrate how a three fingered gripper can be designed and simulated to provide both gross motion and fine motion to the fingers. ... This mimicry is required to design the correct motions and tactile forces necessary to handle delicate and non delicate engineering components.

  20. Fifteen years experience with finger arterial pressure monitoring : Assessment of the technology

    NARCIS (Netherlands)

    Imholz, B.P.M.; Wieling, W.; Montfrans, G.A. van; Wesseling, K.H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in

  1. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology

    NARCIS (Netherlands)

    Imholz, B. P.; Wieling, W.; van Montfrans, G. A.; Wesseling, K. H.

    1998-01-01

    We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in

  2. [Necrosis in fingers and toes following local anaesthesia with adrenaline--an urban legend?].

    Science.gov (United States)

    Finsen, Vilhjalmur

    2013-09-17

    It is often maintained that a local anaesthetic (usually lidocaine) with adrenaline must not be used in fingers and toes because it may cause necrosis due to vascular spasm in end arteries. This review article is an attempt to find evidence to support this warning. Relevant literature was found by means of searches in PubMed limited downwards to 1946 and in EMBASE from 1980 to 2012, and in reference lists. Five review articles on finger necrosis following local anaesthesia concluded that lidocaine with adrenaline does not entail a risk of ischaemic injury. One article found 48 reported cases of finger necrosis in the period 1880 to 2000. Most were from the first half of the 1900s, and none involved lidocaine. Gangrene of part of the finger tip has subsequently been described in one patient with Raynaud's syndrome. No cases of necrosis have been described in a large number of reported accidents in which EpiPen injections contained the same quantity of adrenaline as is found in 60 ml lidocaine with adrenaline. Over a quarter of a million reports have been made of operations on feet, hands, fingers and toes anaesthetised with lidocaine with adrenaline without resulting necrosis. There are no grounds for the warning against using lidocaine with adrenaline in fingers and toes. This anaesthetic offers considerable practical advantages. Care should be taken with infected fingers or fingers with poor circulation.

  3. Impaired Finger Dexterity in Parkinson's Disease Is Associated with Praxis Function

    Science.gov (United States)

    Vanbellingen, T.; Kersten, B.; Bellion, M.; Temperli, P.; Baronti, F.; Muri, R.; Bohlhalter, S.

    2011-01-01

    A controversial concept suggests that impaired finger dexterity in Parkinson's disease may be related to limb kinetic apraxia that is not explained by elemental motor deficits such as bradykinesia. To explore the nature of dexterous difficulties, the aim of the present study was to assess the relationship of finger dexterity with ideomotor praxis…

  4. Human motor cortical activity recorded with Micro-ECoG electrodes, during individual finger movements.

    Science.gov (United States)

    Wang, W; Degenhart, A D; Collinger, J L; Vinjamuri, R; Sudre, G P; Adelson, P D; Holder, D L; Leuthardt, E C; Moran, D W; Boninger, M L; Schwartz, A B; Crammond, D J; Tyler-Kabara, E C; Weber, D J

    2009-01-01

    In this study human motor cortical activity was recorded with a customized micro-ECoG grid during individual finger movements. The quality of the recorded neural signals was characterized in the frequency domain from three different perspectives: (1) coherence between neural signals recorded from different electrodes, (2) modulation of neural signals by finger movement, and (3) accuracy of finger movement decoding. It was found that, for the high frequency band (60-120 Hz), coherence between neighboring micro-ECoG electrodes was 0.3. In addition, the high frequency band showed significant modulation by finger movement both temporally and spatially, and a classification accuracy of 73% (chance level: 20%) was achieved for individual finger movement using neural signals recorded from the micro-ECoG grid. These results suggest that the micro-ECoG grid presented here offers sufficient spatial and temporal resolution for the development of minimally-invasive brain-computer interface applications.

  5. Luciferase-Zinc-Finger System for the Rapid Detection of Pathogenic Bacteria.

    Science.gov (United States)

    Shi, Chu; Xu, Qing; Ge, Yue; Jiang, Ling; Huang, He

    2017-08-09

    Rapid and reliable detection of pathogenic bacteria is crucial for food safety control. Here, we present a novel luciferase-zinc finger system for the detection of pathogens that offers rapid and specific profiling. The system, which uses a zinc-finger protein domain to probe zinc finger recognition sites, was designed to bind the amplified conserved regions of 16S rDNA, and the obtained products were detected using a modified luciferase. The luciferase-zinc finger system not only maintained luciferase activity but also allowed the specific detection of different bacterial species, with a sensitivity as low as 10 copies and a linear range from 10 to 10 4 copies per microliter of the specific PCR product. Moreover, the system is robust and rapid, enabling the simultaneous detection of 6 species of bacteria in artificially contaminated samples with excellent accuracy. Thus, we envision that our luciferase-zinc finger system will have far-reaching applications.

  6. Finger-Based Numerical Skills Link Fine Motor Skills to Numerical Development in Preschoolers.

    Science.gov (United States)

    Suggate, Sebastian; Stoeger, Heidrun; Fischer, Ursula

    2017-12-01

    Previous studies investigating the association between fine-motor skills (FMS) and mathematical skills have lacked specificity. In this study, we test whether an FMS link to numerical skills is due to the involvement of finger representations in early mathematics. We gave 81 pre-schoolers (mean age of 4 years, 9 months) a set of FMS measures and numerical tasks with and without a specific finger focus. Additionally, we used receptive vocabulary and chronological age as control measures. FMS linked more closely to finger-based than to nonfinger-based numerical skills even after accounting for the control variables. Moreover, the relationship between FMS and numerical skill was entirely mediated by finger-based numerical skills. We concluded that FMS are closely related to early numerical skill development through finger-based numerical counting that aids the acquisition of mathematical mental representations.

  7. Decontamination in the Electron Probe Microanalysis with a Peltier-Cooled Cold Finger.

    Science.gov (United States)

    Buse, Ben; Kearns, Stuart; Clapham, Charles; Hawley, Donovan

    2016-10-01

    A prototype Peltier thermoelectric cooling unit has been constructed to cool a cold finger on an electron microprobe. The Peltier unit was tested at 15 and 96 W, achieving cold finger temperatures of -10 and -27°C, respectively. The Peltier unit did not adversely affect the analytical stability of the instrument. Heat conduction between the Peltier unit mounted outside the vacuum and the cold finger was found to be very efficient. Under Peltier cooling, the vacuum improvement associated with water vapor deposition was not achieved; this has the advantage of avoiding severe degradation of the vacuum observed when warming up a cold finger from liquid nitrogen (LN2) temperatures. Carbon contamination rates were reduced as cooling commenced; by -27°C contamination rates were found to be comparable with LN2-cooled devices. Peltier cooling, therefore, provides a viable alternative to LN2-cooled cold fingers, with few of their associated disadvantages.

  8. Role of zinc finger structure in nuclear localization of transcription factor Sp1

    International Nuclear Information System (INIS)

    Ito, Tatsuo; Azumano, Makiko; Uwatoko, Chisana; Itoh, Kohji; Kuwahara, Jun

    2009-01-01

    Transcription factor Sp1 is localized in the nucleus and regulates gene expression. Our previous study demonstrated that the carboxyl terminal region of Sp1 containing 3-zinc finger region as DNA binding domain can also serve as nuclear localization signal (NLS). However, the nuclear transport mechanism of Sp1 has not been well understood. In this study, we performed a gene expression study on mutant Sp1 genes causing a set of amino acid substitutions in zinc finger domains to elucidate nuclear import activity. Nuclear localization of the GFP-fused mutant Sp1 proteins bearing concomitant substitutions in the first and third zinc fingers was highly inhibited. These mutant Sp1 proteins had also lost the binding ability as to the GC box sequence. The results suggest that the overall tertiary structure formed by the three zinc fingers is essential for nuclear localization of Sp1 as well as dispersed basic amino acids within the zinc fingers region.

  9. Design and control of five fingered under-actuated robotic hand

    Science.gov (United States)

    Sahoo, Biswojit; Parida, Pramod Kumar

    2018-04-01

    Now a day's research regarding humanoid robots and its application in different fields (industry, household, rehabilitation and exploratory) is going on entire the globe. Among which a challenging topic is to design a dexterous robotic hand which not only can perform as a hand of a robot but also can be used in re habilitation. The basic key concern is a dexterous robot hand which can be able to mimic the function of biological hand to perform different operations. This thesis work is regarding design and control of a under-actuated robotic hand consisting of four under actuated fingers (index finger, middle finger, little finger and ring finger ) , a thumb and a dexterous palm which can copy the motions and grasp type of human hand which having 21degrees of freedom instead of 25Degree Of Freedom.

  10. The Case Report of Trigger Finger Improved with Hominis Placenta Pharmacopuncture Treatment

    Directory of Open Access Journals (Sweden)

    Jeong-Won Kim

    2010-12-01

    Full Text Available Objectives : The Purpose of this study is to investigate and report the effectiveness of Hominis Placenta using Pharmacopuncture treatment for trigger finger. Methods : 3 Patients are admitted at Dept. of Oriental Rehabilitation, Bu-Chun Jaseng Oriental Medicine Hospital, diagnosed as Trigger finger and treated with Hominis Placenta Pharmacopuncture. Each cases are measured and assessed by Quinnell's classification of triggering and VAS (Visual Analogue Scale scores. Results : 3 Patients of trigger finger have a different kind of cause and fingers lesion they have, but nodules are not significantly found up, so we could classify all of 3 patients to diffuse type. After treatment of Hominis placenta Pharmacopuncture, spontaneous pain and tenderness, grades of triggering are decreased significantly. We would expect that Hominis placenta Pharmacopuncture has a effect on degenerative diseases of diffuse type's tendon sheath. Conclusions : Trigger finger is generally divided into two stages, inflammatory and degenerative stage, and when degenerative stage, Hominis placenta pharmacopuncture appears to be effective.

  11. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  12. Giant Cell Tumour of Tendon Sheath Masquerading As Trigger Finger

    Directory of Open Access Journals (Sweden)

    N Rahimawati

    2010-11-01

    Full Text Available We report a case of a 59-year-old female who presented in the general orthopaedic clinic with triggering of her right middle finger. She did not respond to conventional treatment methods; subsequently she underwent surgical open release under local anaesthesia. Five months postoperatively, the patient presented with signs and symptoms of acute flexor tenosynovitis, and was thought to have a postoperative infection. Re-examination by a hand surgeon raised the possibility of a different aetiology. Based on clinical findings and response to initial treatment, giant cell tumour of the flexor tendon sheath was suspected and later confirmed following surgical biopsy. A high index of suspicion and knowledge of the variegated presentations of giant cell tumour in the hand are beneficial in these types of cases.

  13. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  14. Influence of Music Style and Rate on Repetitive Finger Tapping.

    Science.gov (United States)

    Stegemöller, Elizabeth L; Tatz, Joshua R; Warnecke, Alison; Hibbing, Paul; Bates, Brandon; Zaman, Andrew

    2018-03-09

    Auditory cues, including music, are commonly used in the treatment of persons with Parkinson's disease. Yet, how music style and movement rate modulate movement performance in persons with Parkinson's disease have been neglected and remain limited in healthy young populations. The purpose of this study was to determine how music style and movement rate influence movement performance in healthy young adults. Healthy participants were asked to perform repetitive finger movements at two pacing rates (70 and 140 beats per minute) for the following conditions: (a) a tone only, (b) activating music, and (c) relaxing music. Electromyography, movement kinematics, and variability were collected. Results revealed that the provision of music, regardless of style, reduced amplitude variability at both pacing rates. Intermovement interval was longer, and acceleration variability was reduced during both music conditions at the lower pacing rate only. These results may prove beneficial for designing therapeutic interventions for persons with Parkinson's disease.

  15. "Finger" structure of tiles in CMS Endcap Hadron Calorimeters

    CERN Document Server

    Afanasiev, Sergey; Danilov, Mikhail; Emeliantchik, Igor; Ershov, Yuri; Golutvin, Igor; Grinyov, B.V; Ibragimova, Elvira; Levchuk, Leonid; Litomin, Aliaksandr; Makankin, Alexander; Malakhov, Alexander; Moisenz, Petr; Nuritdinov, I; Popov, V.F; Rusinov, Vladimir; Shumeiko, Nikolai; Smirnov, Vitaly; Sorokin, Pavlo; Tarkovskiy, Evgueni; Tashmetov, A; Vasiliev, S.E; Yuldashev, Bekhzod; Zamyatin, Nikolay; Zhmurin, Petro

    2015-01-01

    Two CMS Endcap hadron calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The HE calorimeter suffered more from the radiation than it had been anticipated because of rapid degradation of scintillator segments (tiles) which have a high radiation flux of secondary particles. Some investigations of scintillators have shown that the degradation of plastic scintillator increases significantly at low dose rates. A proposal to upgrade up-grade the HE calorimeter has been prepared to provide a solution for survivability of the future LHC at higher luminosity and higher energy. A finger-strip plastic scintillator option has many advantages and is a lower cost alternative to keep the excellent HE performance at high luminosity. Measurements have been performed and this method has proved to be a good upgrade strategy.

  16. Spatial Memory for Patterns of Taps on the Fingers.

    Science.gov (United States)

    Markel, Paul D

    2015-01-01

    Ongoing development of haptic technology has the potential to provide significant improvement in safety and performance in demanding environments where vision and hearing are compromised. Research regarding the cognitive psychology of touch is lacking and could be beneficial in the development of expectations about human performance for the refinement and implementation of haptic technology. This study examines haptic-spatial memory using a novel assessment method based on finger anatomy. In addition, evidence is presented for a serial-position effect for haptic-spatial memory that is analogous to the classic serial-position effect demonstrated in the verbal recall of word lists. Finally, haptic-spatial memory is compared with short- and long-term memory for visual-spatial tasks.

  17. A FYVE zinc finger domain protein specifically links mRNA transport to endosome trafficking

    Science.gov (United States)

    Pohlmann, Thomas; Baumann, Sebastian; Haag, Carl; Albrecht, Mario; Feldbrügge, Michael

    2015-01-01

    An emerging theme in cellular logistics is the close connection between mRNA and membrane trafficking. A prominent example is the microtubule-dependent transport of mRNAs and associated ribosomes on endosomes. This coordinated process is crucial for correct septin filamentation and efficient growth of polarised cells, such as fungal hyphae. Despite detailed knowledge on the key RNA-binding protein and the molecular motors involved, it is unclear how mRNAs are connected to membranes during transport. Here, we identify a novel factor containing a FYVE zinc finger domain for interaction with endosomal lipids and a new PAM2-like domain required for interaction with the MLLE domain of the key RNA-binding protein. Consistently, loss of this FYVE domain protein leads to specific defects in mRNA, ribosome, and septin transport without affecting general functions of endosomes or their movement. Hence, this is the first endosomal component specific for mRNP trafficking uncovering a new mechanism to couple mRNPs to endosomes. DOI: http://dx.doi.org/10.7554/eLife.06041.001 PMID:25985087

  18. A FYVE zinc finger domain protein specifically links mRNA transport to endosome trafficking.

    Science.gov (United States)

    Pohlmann, Thomas; Baumann, Sebastian; Haag, Carl; Albrecht, Mario; Feldbrügge, Michael

    2015-05-18

    An emerging theme in cellular logistics is the close connection between mRNA and membrane trafficking. A prominent example is the microtubule-dependent transport of mRNAs and associated ribosomes on endosomes. This coordinated process is crucial for correct septin filamentation and efficient growth of polarised cells, such as fungal hyphae. Despite detailed knowledge on the key RNA-binding protein and the molecular motors involved, it is unclear how mRNAs are connected to membranes during transport. Here, we identify a novel factor containing a FYVE zinc finger domain for interaction with endosomal lipids and a new PAM2-like domain required for interaction with the MLLE domain of the key RNA-binding protein. Consistently, loss of this FYVE domain protein leads to specific defects in mRNA, ribosome, and septin transport without affecting general functions of endosomes or their movement. Hence, this is the first endosomal component specific for mRNP trafficking uncovering a new mechanism to couple mRNPs to endosomes.

  19. Endurance exercise training increases peripheral vascular response in human fingers.

    Science.gov (United States)

    Katayama, K; Shimoda, M; Maeda, J; Takemiya, T

    1998-10-01

    The purpose of this study was to clarify whether peripheral vascular response to alteration of transmural pressure is changed by endurance exercise training. The healthy male subjects (training group; n = 6) performed endurance exercise training that consisted of cycle ergometer exercise 5 d.week-1 and 30 min.d-1 for a period of 8 weeks. Changes in the peripheral vascular response to alteration of transmural pressure in the human finger were measured by a differential digital photoplethysmogram (DeltaDPG) and blood pressure during passive movement of the arm to different vertical hand positions relative to heart level. Following 8 weeks of endurance training, percent changes in DeltaDPG from heart level in the training group increased significantly (mean +/- SD, -48.1 +/- 7. 3 to -58.7 +/- 9.3% at the lowered position, 46.1 +/- 13.4 to 84.6 +/- 8.8% at the elevated position, ppressure, also significantly changed in the training group over the 8 weeks (5.6 +/- 1.3 to 2.7 +/- 1.6 mV. V-1.s-1.mmHg-1 at the lowered position, 30.0 +/- 12.4 to 54.4 +/- 18. 9 mV.V-1.s-1.mmHg-1 at the elevated position ). Maximal oxygen uptake (V.O2 max) was significantly increased in the training group. On the other hand, the control group (n = 6) showed no significant changes in all parameters for 8 weeks. Therefore these results suggest that endurance exercise training induces an increase in peripheral vascular response to alteration of transmural pressure in the human finger.

  20. Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.

    Science.gov (United States)

    Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C

    2005-08-15

    Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.

  1. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers by ...

  2. Comparative Performance Analysis of G-RAKE Receivers with Suboptimal Finger Placement

    Directory of Open Access Journals (Sweden)

    K. B. Baltzis

    2014-07-01

    Full Text Available Generalized RAKE (G-RAKE reception reduces the total amount of interference and provides enhanced diversity by comprising extra fingers to collect information about interference and further using channel and impairment correlation estimates for fingers allocation. However, the hardware complexity and the excessive computational requirements of GRAKE receivers may restrict their application in real systems; thus, suboptimal solutions are commonly used. In this paper, we propose and evaluate three maximum likelihood G-RAKE structures for colored noise with suboptimal finger placement. In all implementations, the fingers are optimally distributed within a time window that spans from several chip periods before the first arriving multipath to several chip periods after the latest one. The first receiver has its fingers at integer multiples of the chip period while in the rest two structures the search window is segmented in halves and tenths of the chip duration. This work also extends earlier studies by thoroughly investigating the impact of fractionally spaced finger placement on system performance. Our analysis shows that a suboptimal finger allocation reduces hardware complexity with negligible performance loss. The impact of channel delay spread and processing gain on system performance is also investigated and gives interesting results.

  3. Fine finger motor skill training with exoskeleton robotic hand in chronic stroke: stroke rehabilitation.

    Science.gov (United States)

    Ockenfeld, Corinna; Tong, Raymond K Y; Susanto, Evan A; Ho, Sze-Kit; Hu, Xiao-ling

    2013-06-01

    Background and Purpose. Stroke survivors often show a limited recovery in the hand function to perform delicate motions, such as full hand grasping, finger pinching and individual finger movement. The purpose of this study is to describe the implementation of an exoskeleton robotic hand together with fine finger motor skill training on 2 chronic stroke patients. Case Descriptions. Two post-stroke patients participated in a 20-session training program by integrating 10 minutes physical therapy, 20 minutes robotic hand training and 15 minutes functional training tasks with delicate objects(card, pen and coin). These two patients (A and B) had cerebrovascular accident at 6 months and 11 months respectively when enrolled in this study. Outcomes. The results showed that both patients had improvements in Fugl-Meyer assessment (FM), Action Research Arm Test (ARAT). Patients had better isolation of the individual finger flexion and extension based on the reduced muscle co-contraction from the electromyographic(EMG) signals and finger extension force after 20 sessions of training. Discussion. This preliminary study showed that by focusing on the fine finger motor skills together with the exoskeleton robotic hand, it could improve the motor recovery of the upper extremity in the fingers and hand function, which were showed in the ARAT. Future randomized controlled trials are needed to evaluate the clinical effectiveness.

  4. Differences in Activation Area Within Brodmann Area 2 Caused by Pressure Stimuli on Fingers and Joints

    Science.gov (United States)

    Choi, Mi-Hyun; Kim, Hyung-Sik; Baek, Ji-Hye; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Gim, Seon-Young; Kim, Sung-Phil; Lim, Dae-Woon; Chung, Soon-Cheol

    2015-01-01

    Abstract In this study, a constant pressure stimulus was applied on the 3 joints (first [p1], second [p2], and third [p3] joints) of 4 fingers (index, middle, ring, and little fingers), and the activation areas within Brodmann area 2 (BA 2) were compared for these different fingers and joints by using functional magnetic resonance imaging. Eight healthy male college students (25.4 ± 1.32 years) participated in the study. Each session was composed of 3 blocks, and each block was composed of a Control phase (30 seconds) and a Pressure phase (30 seconds). No pressure stimulus was applied in the Control phase, during which the subjects would simply lay comfortably with their eyes closed. In the Pressure phase, a pressure stimulus was applied onto one of the joints of the selected finger. For each finger and joint, BA 2 areas activated by the pressure stimulus were extracted by the region of interest method. There was a significant difference in the activation areas for the different fingers (P = .042) as well as for the different joints (P = .050). The activation area decreased in the order of the little, index, and middle fingers, as well as in the order of p1, p3, and p2. PMID:26402840

  5. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for

  6. Real time relationship between individual finger force and grip exertion on distal phalanges in linear force following tasks.

    Science.gov (United States)

    Luo, Shi-Jian; Shu, Ge; Gong, Yan

    2018-05-01

    Individual finger force (FF) in a grip task is a vital concern in rehabilitation engineering and precise control of manipulators because disorders in any of the fingers will affect the stability or accuracy of the grip force (GF). To understand the functions of each finger in a dynamic grip exertion task, a GF following experiment with four individual fingers without thumb was designed. This study obtained four individual FFs from the distal phalanges with a cylindrical handle in dynamic GF following tasks. Ten healthy male subjects with similar hand sizes participated in the four-finger linear GF following tasks at different submaximal voluntary contraction (SMVC) levels. The total GF, individual FF, finger force contribution, and following error were subsequently calculated and analyzed. The statistics indicated the following: 1) the accuracy and stability of GF at low %MVC were significantly higher than those at high SMVC; 2) at low SMVC, the ability of the fingers to increase the GF was better than the ability to reduce it, but it was contrary at high SMVC; 3) when the target wave (TW) was changing, all four fingers strongly participated in the force exertion, but the participation of the little finger decreased significantly when TW remained stable; 4) the index finger and ring finger had a complementary relationship and played a vital role in the adjustment and control of GF. The middle finger and little finger had a minor influence on the force control and adjustment. In conclusion, each of the fingers had different functions in a GF following task. These findings can be used in the assessment of finger injury rehabilitation and for algorithms of precise control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Natural Touch Interaction for Virtual Reality and Teleoperation via Ungrounded Tactile Shear Feedback, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed research innovation will create a low-cost, intuitive means for people to have multi-fingered interaction with Robonaut 2 and training simulations via...

  8. Finger temperature as a predictor of thermal comfort for sedentary passengers in a simulated aircraft cabin

    DEFF Research Database (Denmark)

    Strøm-Tejsen, Peter; Wyon, David Peter; Zukowska, Daria

    2009-01-01

    .1°C. A total of 68 subjects were exposed to each of the three conditions. The subjects completed questionnaires to provide subjective assessments of air quality, cabin environment, intensity of symptoms commonly experienced during flight, and thermal comfort. Objective physiological measurements...... that were made included finger temperature. The purpose of the present paper is to show that mean finger temperature is a good predictor of mean thermal vote (MTV) on the seven-point scale of thermal sensation. The results indicate that women and younger subjects have slightly colder fingers....

  9. Structural basis for ubiquitin recognition by ubiquitin-binding zinc finger of FAAP20.

    Directory of Open Access Journals (Sweden)

    Aya Toma

    Full Text Available Several ubiquitin-binding zinc fingers (UBZs have been reported to preferentially bind K63-linked ubiquitin chains. In particular, the UBZ domain of FAAP20 (FAAP20-UBZ, a member of the Fanconi anemia core complex, seems to recognize K63-linked ubiquitin chains, in order to recruit the complex to DNA interstrand crosslinks and mediate DNA repair. By contrast, it is reported that the attachment of a single ubiquitin to Rev1, a translesion DNA polymerase, increases binding of Rev1 to FAAP20. To clarify the specificity of FAAP20-UBZ, we determined the crystal structure of FAAP20-UBZ in complex with K63-linked diubiquitin at 1.9 Å resolution. In this structure, FAAP20-UBZ interacts only with one of the two ubiquitin moieties. Consistently, binding assays using surface plasmon resonance spectrometry showed that FAAP20-UBZ binds ubiquitin and M1-, K48- and K63-linked diubiquitin chains with similar affinities. Residues in the vicinity of Ala168 within the α-helix and the C-terminal Trp180 interact with the canonical Ile44-centered hydrophobic patch of ubiquitin. Asp164 within the α-helix and the C-terminal loop mediate a hydrogen bond network, which reinforces ubiquitin-binding of FAAP20-UBZ. Mutations of the ubiquitin-interacting residues disrupted binding to ubiquitin in vitro and abolished the accumulation of FAAP20 to DNA damage sites in vivo. Finally, structural comparison among FAAP20-UBZ, WRNIP1-UBZ and RAD18-UBZ revealed distinct modes of ubiquitin binding. UBZ family proteins could be divided into at least three classes, according to their ubiquitin-binding modes.

  10. Intrinsic and extrinsic connections of Tet3 dioxygenase with CXXC zinc finger modules.

    Directory of Open Access Journals (Sweden)

    Nan Liu

    Full Text Available Tet proteins are emerging as major epigenetic modulators of cell fate and plasticity. However, little is known about how Tet proteins are targeted to selected genomic loci in distinct biological contexts. Previously, a CXXC-type zinc finger domain in Tet1 was shown to bind CpG-rich DNA sequences. Interestingly, in human and mouse the Tet2 and Tet3 genes are adjacent to Cxxc4 and Cxxc10-1, respectively. The CXXC domains encoded by these loci, together with those in Tet1 and Cxxc5, identify a distinct homology group within the CXXC domain family. Here we provide evidence for alternative mouse Tet3 transcripts including the Cxxc10-1 sequence (Tet3(CXXC and for an interaction between Tet3 and Cxxc4. In vitro Cxxc4 and the isolated CXXC domains of Tet1 and Tet3(CXXC bind DNA substrates with similar preference towards the modification state of cytosine at a single CpG site. In vivo Tet1 and Tet3 isoforms with and without CXXC domain hydroxylate genomic 5-methylcytosine with similar activity. Relative transcript levels suggest that distinct ratios of Tet3(CXXC isoforms and Tet3-Cxxc4 complex may be present in adult tissues. Our data suggest that variable association with CXXC modules may contribute to context specific functions of Tet proteins.

  11. Risk of hearing loss among workers with vibration-induced white fingers.

    Science.gov (United States)

    Pettersson, Hans; Burström, Lage; Hagberg, Mats; Lundström, Ronnie; Nilsson, Tohr

    2014-12-01

    We examined the risk of hearing loss for workers who use hand-held vibrating tools with vibration-induced white fingers (VWF) compared to workers without VWF. Data on 184 participants from a 21-year cohort were gathered with questionnaires and measurements. The effects on hearing status of VWF, hand-arm vibration exposure, smoking habits, age and two-way interactions of these independent variables were examined with binary logistic regression. Analyses were made for the right hand and ear as well as for the hand with VWF and the ear with worse categorized hearing status. Workers with VWF in their right hand had an increased risk of hearing loss (odds ratio 2.2-2.3) in the right ear. Workers with VWF in any hand did not have any increased risk of hearing loss in the ear with worse hearing status. This study supports the hypothesis that VWF increases the risk of hearing loss among workers who use hand-held vibrating tools in a noisy environment. © 2014 Wiley Periodicals, Inc.

  12. Sustained-Paced Finger Tapping: A Novel Approach to Measure Internal Sustained Attention

    Directory of Open Access Journals (Sweden)

    Marco A. Petilli

    2018-05-01

    Full Text Available Sustained attention is a fundamental prerequisite for all cognitive functions and its impairment is a common aftermath of both developmental and acquired neurological disorders. To date, all the sustained attention tasks rely heavily on selective attention to external stimuli. The interaction between selective and sustained attention represents a limit in the field of assessment and may mislead researchers or distort conclusions. The aim of the present perspective study was to propose a sustained version of the Paced Finger Tapping (S-PFT test as a novel approach to measure sustained attention that does not leverage external stimuli. Here, we administered S-PFT and other attentional tasks (visual sustained attention, visuospatial attention capacity, selective attention, and divided attention tasks to 85 adolescents. Thus, we provide evidence suggesting that S-PFT is effective in causing performance decrement over time, an important trademark of sustained attention tasks. We also present descriptive statistics showing the relationship between S-PFT and the other attentional tasks. These analyses show that, unlike visual sustained attention tests, performances to our task of internal sustained attention were not correlated to measures of selective attention and visuospatial attention capacity. Our results suggest that S-PFT could represent a promising and alternative tool both for empirical research and clinical assessment of sustained attention.

  13. FINGERING CONVECTION AND CLOUDLESS MODELS FOR COOL BROWN DWARF ATMOSPHERES

    International Nuclear Information System (INIS)

    Tremblin, P.; Amundsen, D. S.; Mourier, P.; Baraffe, I.; Chabrier, G.; Drummond, B.; Homeier, D.; Venot, O.

    2015-01-01

    This work aims to improve the current understanding of the atmospheres of brown dwarfs, especially cold ones with spectral types T and Y, whose modeling is a current challenge. Silicate and iron clouds are believed to disappear at the photosphere at the L/T transition, but cloudless models fail to reproduce correctly the spectra of T dwarfs, advocating for the addition of more physics, e.g., other types of clouds or internal energy transport mechanisms. We use a one-dimensional radiative/convective equilibrium code ATMO to investigate this issue. This code includes both equilibrium and out-of-equilibrium chemistry and solves consistently the PT structure. Included opacity sources are H 2 -H 2 , H 2 -He, H 2 O, CO, CO 2 , CH 4 , NH 3 , K, Na, and TiO, VO if they are present in the atmosphere. We show that the spectra of Y dwarfs can be accurately reproduced with a cloudless model if vertical mixing and NH 3 quenching are taken into account. T dwarf spectra still have some reddening in, e.g., J–H, compared to cloudless models. This reddening can be reproduced by slightly reducing the temperature gradient in the atmosphere. We propose that this reduction of the stabilizing temperature gradient in these layers, leading to cooler structures, is due to the onset of fingering convection, triggered by the destabilizing impact of condensation of very thin dust

  14. FINGERING CONVECTION AND CLOUDLESS MODELS FOR COOL BROWN DWARF ATMOSPHERES

    Energy Technology Data Exchange (ETDEWEB)

    Tremblin, P.; Amundsen, D. S.; Mourier, P.; Baraffe, I.; Chabrier, G.; Drummond, B. [Astrophysics Group, University of Exeter, EX4 4QL Exeter (United Kingdom); Homeier, D. [Ecole Normale Supérieure de Lyon, CRAL, UMR CNRS 5574, F-69364 Lyon Cedex 07 (France); Venot, O., E-mail: tremblin@astro.ex.ac.uk, E-mail: pascal.tremblin@cea.fr [Instituut voor Sterrenkunde, Katholieke Universiteit Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium)

    2015-05-01

    This work aims to improve the current understanding of the atmospheres of brown dwarfs, especially cold ones with spectral types T and Y, whose modeling is a current challenge. Silicate and iron clouds are believed to disappear at the photosphere at the L/T transition, but cloudless models fail to reproduce correctly the spectra of T dwarfs, advocating for the addition of more physics, e.g., other types of clouds or internal energy transport mechanisms. We use a one-dimensional radiative/convective equilibrium code ATMO to investigate this issue. This code includes both equilibrium and out-of-equilibrium chemistry and solves consistently the PT structure. Included opacity sources are H{sub 2}-H{sub 2}, H{sub 2}-He, H{sub 2}O, CO, CO{sub 2}, CH{sub 4}, NH{sub 3}, K, Na, and TiO, VO if they are present in the atmosphere. We show that the spectra of Y dwarfs can be accurately reproduced with a cloudless model if vertical mixing and NH{sub 3} quenching are taken into account. T dwarf spectra still have some reddening in, e.g., J–H, compared to cloudless models. This reddening can be reproduced by slightly reducing the temperature gradient in the atmosphere. We propose that this reduction of the stabilizing temperature gradient in these layers, leading to cooler structures, is due to the onset of fingering convection, triggered by the destabilizing impact of condensation of very thin dust.

  15. Cryptosystem Based On Finger Vein Patterns Using Vas Algorithm

    Directory of Open Access Journals (Sweden)

    G.Kanimozhi

    2015-08-01

    Full Text Available Cryptosystems based on biometrics authentication is developing areas in the field of modernize security schemes. Elastic distortion of fingerprints is one of the major causes for false non-match. While this problem affects all fingerprint identification function it is especially dangerous in opposite identification function such as note list and reduplication function. In such function malicious possessors may purposely distort their fingerprints to evade identification. Distortion rectification or equivalently distortion field estimation is viewed as a regression problem where the input is a distorted fingerprint and the output is the distortion field. The current document deals with the application of finger veins pattern as an approach for possessor confirmation and encryption key generation. The design of the optical imprison scheme by near infrared is described. We propose a step for the location of the vein crossing points and the quantification of the angles between the vein-branches this information is used to generate a personal key that allows the possessor to encrypt information after the confirmation is approved. In order to demonstrate the potential of the suggested approach and model of figure encryption is developed. All action biometric imprison figure presetting key generation and figure encryption are performed on the identical hidden platform adding an important portability and diminishing the execution time.

  16. Contingent sounds change the mental representation of one's finger length.

    Science.gov (United States)

    Tajadura-Jiménez, Ana; Vakali, Maria; Fairhurst, Merle T; Mandrigin, Alisa; Bianchi-Berthouze, Nadia; Deroy, Ophelia

    2017-07-18

    Mental body-representations are highly plastic and can be modified after brief exposure to unexpected sensory feedback. While the role of vision, touch and proprioception in shaping body-representations has been highlighted by many studies, the auditory influences on mental body-representations remain poorly understood. Changes in body-representations by the manipulation of natural sounds produced when one's body impacts on surfaces have recently been evidenced. But will these changes also occur with non-naturalistic sounds, which provide no information about the impact produced by or on the body? Drawing on the well-documented capacity of dynamic changes in pitch to elicit impressions of motion along the vertical plane and of changes in object size, we asked participants to pull on their right index fingertip with their left hand while they were presented with brief sounds of rising, falling or constant pitches, and in the absence of visual information of their hands. Results show an "auditory Pinocchio" effect, with participants feeling and estimating their finger to be longer after the rising pitch condition. These results provide the first evidence that sounds that are not indicative of veridical movement, such as non-naturalistic sounds, can induce a Pinocchio-like change in body-representation when arbitrarily paired with a bodily action.

  17. Osteoclastic finger arthrosis - a subtype of polyarthrosis of the hand

    International Nuclear Information System (INIS)

    Dihlmann, W.; Dihlmann, A.

    1998-01-01

    Aim: Description of a subtype of arthrosis deformans of the hand which is characterised as osteoclastic arthrosis. Patients and methods: Retrospective analysis of radiographs of the hands of 150 women and 100 men with radiological findings of arthrosis deformans. Results: 5% of women and 2% of men showed at least one digital joint with subchondral osteolysis of one or both articulating bones involving at least a third of the phalanx. This subchondral osteolysis far exceeds the cysts which are situated in the epiphyseal part of the articular region. It may develop within a year. Conclusion: Osteoclastic arthrosis of the finger is a subtype of polyarthrosis of the hand. Serial observations suggest that an osteoclast stimulating substance is produced by the cysts or arises directly from the synovial fluid; this enters the subchondral part of the bone through clefts which may or may not be visible radiologically and that this produces osteoclastic activity. The most important differential diagnoses are chronic tophacious gout and a benign tumor. (orig.) [de

  18. (AMMI) and genotype by environment interaction

    African Journals Online (AJOL)

    SARAH

    2014-04-30

    Apr 30, 2014 ... Background and justification: Lack of stable high yielding cultivars is one ... of advanced finger millet genotypes evaluated in multiple environments, and (ii) identify stable high yielding .... for interaction principal component axis (IPCA) n, γgn ..... Table 2: Analysis of variance for grain yield using AMMI model.

  19. Comparing kinematic changes between a finger-tapping task and unconstrained finger flexion-extension task in patients with Parkinson's disease.

    Science.gov (United States)

    Teo, W P; Rodrigues, J P; Mastaglia, F L; Thickbroom, G W

    2013-06-01

    Repetitive finger tapping is a well-established clinical test for the evaluation of parkinsonian bradykinesia, but few studies have investigated other finger movement modalities. We compared the kinematic changes (movement rate and amplitude) and response to levodopa during a conventional index finger-thumb-tapping task and an unconstrained index finger flexion-extension task performed at maximal voluntary rate (MVR) for 20 s in 11 individuals with levodopa-responsive Parkinson's disease (OFF and ON) and 10 healthy age-matched controls. Between-task comparisons showed that for all conditions, the initial movement rate was greater for the unconstrained flexion-extension task than the tapping task. Movement rate in the OFF state was slower than in controls for both tasks and normalized in the ON state. The movement amplitude was also reduced for both tasks in OFF and increased in the ON state but did not reach control levels. The rate and amplitude of movement declined significantly for both tasks under all conditions (OFF/ON and controls). The time course of rate decline was comparable for both tasks and was similar in OFF/ON and controls, whereas the tapping task was associated with a greater decline in MA, both in controls and ON, but not OFF. The findings indicate that both finger movement tasks show similar kinematic changes during a 20-s sustained MVR, but that movement amplitude is less well sustained during the tapping task than the unconstrained finger movement task. Both movement rate and amplitude improved with levodopa; however, movement rate was more levodopa responsive than amplitude.

  20. Effect of finger motion on transverse median nerve movement in the carpal tunnel.

    Science.gov (United States)

    Kang, Hyo Jung; Yoon, Joon Shik

    2016-10-01

    We used ultrasonography (US) to investigate the effects of finger motion on movement of the median nerve in patients with carpal tunnel syndrome (CTS) and the correlation between these US parameters and CTS severity. Ultrasonographic measures were performed in 23 control wrists and 22 CTS wrists in women. During first through third finger flexion and grip motion, median nerve movements were obtained using US and a tracing program. Nerve movements during third finger flexion in the dorsopalmar axis and grip motion in both axes, and during second finger flexion in the radioulnar axis, differed significantly between the control and CTS groups. US parameters correlated negatively with cross-sectional area. This study shows that transverse median nerve movements decreased during grip using US and correlated negatively with CTS severity. Muscle Nerve, 2016 Muscle Nerve 54: -, 2016 Muscle Nerve 54: 738-742, 2016. © 2016 Wiley Periodicals, Inc.

  1. Determining the number of fingers in the lifting Hele-Shaw problem

    Science.gov (United States)

    Miranda, Jose; Dias, Eduardo

    2013-11-01

    The lifting Hele-Shaw cell flow is a variation of the celebrated radial viscous fingering problem for which the upper cell plate is lifted uniformly at a specified rate. This procedure causes the formation of intricate interfacial patterns. Most theoretical studies determine the total number of emerging fingers by maximizing the linear growth rate, but this generates discrepancies between theory and experiments. In this work, we tackle the number of fingers selection problem in the lifting Hele-Shaw cell by employing the recently proposed maximum-amplitude criterion. Our linear stability analysis accounts for the action of capillary, viscous normal stresses, and wetting effects, as well as the cell confinement. The comparison of our results with very precise laboratory measurements for the total number of fingers shows a significantly improved agreement between theoretical predictions and experimental data. We thank CNPq (Brazilian Sponsor) for financial support.

  2. Osmosis-driven viscous fingering of oil-in-water emulsions

    Science.gov (United States)

    Liu, Ying; Rallabandi, Bhargav; Baskaran, Mrudhula; Stone, Howard

    2017-11-01

    Viscous fingering occurs when a low viscosity fluid invades a more viscous fluid. Fingering of two miscible fluids is more complicated than that of immiscible fluids in that there is no sharp fluid-fluid interface and diffusion occurs between the phases. We experimentally studied the fingering of two miscible fluids: an oil-in-water emulsion and a sodium chloride solution. When the concentration of sodium chloride in the water phase in the emulsion exceeds that in the sodium chloride solution, the consequent osmotic flow automatically facilitates the occurrence of the fingering. On the contrary, when the sodium chloride solution has higher concentration, the spreading of emulsion is more uniform than the case without the concentration difference. We provide a model to rationalize and quantify these observations.

  3. RETRACTED ARTICLE: Nutritional, technological, and medical approach of finger millet (Eleusine coracana

    Directory of Open Access Journals (Sweden)

    Amir Gull

    2015-12-01

    Full Text Available Finger millet (Eleusine coracana L. is also known as African millet and is commonly called “ragi” in India. It has excellent nutritional value and is even superior to other common cereals. It is a richest source of calcium (344 mg and magnesium (408 mg than other millets. Predominant fatty acids of this millet are oleic (49%, linoleic (25%, and palmitic acids (25%. Finger millet contains both water-soluble and lipo-soluble vitamins. Emerging bakery products prepared from this millet are pasta, noodles, vermicelli, and bread. Being gluten free, it is suitable for individuals suffering from celiac disease. Finger millet grain is a rich source of several phytochemicals. Finger millet possesses blood glucose lowering, cholesterol lowering, and antiulcerative, wound healing properties as indicated by in vitro and in vivo studies. Commonly used processing techniques for this millet are milling, malting, popping, and decortications.

  4. Interobserver Variability in the Treatment of Little Finger Metacarpal Neck Fractures

    NARCIS (Netherlands)

    Tosti, Rick; Ilyas, Asif M.; Mellema, Jos J.; Guitton, Thierry G.; Ring, David; Spoor, A. B.; Shafritz, A. B.; Platz, A.; Berner, A.; Terrono, A. L.; Jubel, A.; Kreis, B. E.; Hearon, B. F.; Bottke, C. A.; Broekhuyse, H.; Buckley, R.; Watkins, B.; Fernandes, C. H.; Metzger, C.; Taleb, C.; Bainbridge, L. C.; Cornell, C.; van Deurzen, D. F. P.; Osei, D. A.; Haverkamp, D.; Oloruntoba, D. O.; Eygendaal, D.; Verbeek, D. O. F.; Kalainov, D. M.; Polatsch, D.; Melvanki, P.; Shafi, M.; van Riet, R.; Ruchelsman, D.; Duncan, S. F.; Pemovska, E. Stojkovska; Tolo, E. T.; Schumer, E. D.; Frihagen, F.; Raia, F. J.; DeSilva, G.; Dyer, G. S. M.; Frykman, G. K.; Doornberg, J. N.; Ponsen, K. J.; Kloen, P.; Haverlag, R.; van den Bekerom, M. P. J.; Goslings, J. C.; Schep, N.

    2014-01-01

    Purpose To address the null hypothesis that surgeons shown radiographs of little finger metacarpal neck fractures with measured fracture angulation would recommend surgery as often as surgeons shown unmarked radiographs. Methods Members of the Science of Variation Group, an international

  5. Place of the reposition flap in the treatment of distal amputations of the fingers

    Directory of Open Access Journals (Sweden)

    Mohamed Ali Sbai

    2017-08-01

    Conclusion: The reposition flap seems to be a good alternative to regularization in the context of trans-p3 fingers amputations, in which the distal fragment is not revascularizable. It allows better aesthetic and functional results.

  6. pathogen isolates of Pyricularia grisea in GULU-E finger millet last

    African Journals Online (AJOL)

    ACSS

    Finger millet is basis for food security which directly supports the livelihoods of rural majority living in ... that resistance was partially dominant and additive, based on mid parent values from crosses. .... Description under artificial infection.

  7. The normal tendon sheath of the second to fifth fingers as seen on oblique views

    International Nuclear Information System (INIS)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis. (orig.) [de

  8. Task-specific kinetic finger tremor affects the performance of carrom players.

    Science.gov (United States)

    Kahathuduwa, Chanaka N; Weerasinghe, Vajira S; Dassanayake, Tharaka L; Priyadarshana, Rajeewa; Dissanayake, Arunika L; Perera, Christine

    2016-01-01

    We aimed to determine the effect of task-specific kinetic finger tremor, as indexed by surface electromyography (EMG), on the accuracy of a carrom stroke. Surface EMG of extensor digitorum communis muscle of the playing arm was recorded during rest, isometric contraction and stroke execution in 17 male carrom players with clinically observed finger tremor and 18 skill- and age-matched controls. Log-transformed power spectral densities (LogPSDs) of surface EMG activity (signifying tremor severity) at a 1-s pre-execution period correlated with angular error of the stroke. LogPSDs in 4-10 Hz range were higher in players with tremor than controls during pre-execution (P kinetic finger tremor in carrom players. This finger tremor during the immediate pre-execution phase appears to be a significant determinant of stroke accuracy.

  9. Brain activity during bilateral rapid alternate finger tapping measured with magnetoencephalography

    Science.gov (United States)

    Fukuda, Hiroshi; Odagaki, Masato; Hiwaki, Osamu; Kodabashi, Atsushi; Fujimoto, Toshiro

    2009-04-01

    Using magnetoencephalography (MEG), brain regions involved in an alternate bimanual tapping task by index fingers triggered with spontaneous timing were investigated. The tapping mode in which both index fingers moved simultaneously was interlaced during the task. The groups of the alternate tapping (AL mode) and the simultaneous tapping (SI mode) were extracted from the successive alternating taps with a histogram of intervals between the right and left index fingers. MEG signals in each mode were averaged separately before and after the tapping initiation of the dominant index finger. The activities of the contralateral sensorimotor cortex before and after the tapping initiation in the AL mode were larger than that in the SI mode. The result indicates that the activity of the contralateral sensorimotor cortex depends on the degree of achievement in the difficult motor task such as the voluntary alternate tapping movements.

  10. MR imaging of the finger tendons: Normal anatomy and commonly encountered pathology

    International Nuclear Information System (INIS)

    Ragheb, Dina; Stanley, Anthony; Gentili, Amilcare; Hughes, Tudor; Chung, Christine B.

    2005-01-01

    MR imaging has emerged as a powerful tool in the evaluation of soft tissue structures such as the tendons of the hand and finger due to its excellent soft tissue contrast and multiplanar imaging capabilities. In the finger and hand, perhaps more than in any other location in the body, a detailed and intimate understanding of anatomy is crucial for lesion localization, directing clinical management and predicting long-term prognosis. These issues are of paramount importance to both the clinician and imager, both faced with the challenge of the complex anatomy and pathology associated with these delicate structures. The anatomy of the finger including intrinsic and extrinsic muscles, retinacular structures, and tendons will be discussed. The MR imaging features of common lesions of the tendons of the hand and finger will be reviewed

  11. Reorganization of finger coordination patterns through motor exploration in individuals after stroke.

    Science.gov (United States)

    Ranganathan, Rajiv

    2017-09-11

    Impairment of hand and finger function after stroke is common and affects the ability to perform activities of daily living. Even though many of these coordination deficits such as finger individuation have been well characterized, it is critical to understand how stroke survivors learn to explore and reorganize their finger coordination patterns for optimizing rehabilitation. In this study, I examine the use of a body-machine interface to assess how participants explore their movement repertoire, and how this changes with continued practice. Ten participants with chronic stroke wore a data glove and the finger joint angles were mapped on to the position of a cursor on a screen. The task of the participants was to move the cursor back and forth between two specified targets on a screen. Critically, the map between the finger movements and cursor motion was altered so that participants sometimes had to generate coordination patterns that required finger individuation. There were two phases to the experiment - an initial assessment phase on day 1, followed by a learning phase (days 2-5) where participants trained to reorganize their coordination patterns. Participants showed difficulty in performing tasks which had maps that required finger individuation, and the degree to which they explored their movement repertoire was directly related to clinical tests of hand function. However, over four sessions of practice, participants were able to learn to reorganize their finger movement coordination pattern and improve their performance. Moreover, training also resulted in improvements in movement repertoire outside of the context of the specific task during free exploration. Stroke survivors show deficits in movement repertoire in their paretic hand, but facilitating movement exploration during training can increase the movement repertoire. This suggests that exploration may be an important element of rehabilitation to regain optimal function.

  12. Women's finger sensitivity correlates with partnered sexual behavior but not solitary masturbation frequencies.

    Science.gov (United States)

    Brody, Stuart; Fischer, Agneta H; Hess, Ursula

    2008-01-01

    In a sample of 97 healthy Dutch female university students, women with greater finger tactile sensitivity (von Frey-type filaments) engaged more in partnered (but not solitary masturbation) sexual behavior. Orgasmic responses in the past 30 days were not correlated with finger sensitivity. Results are discussed in terms of differences between different sexual behaviors, as well as susceptibility to reinforcement, and psychoanalytic views of conversion hysteria.

  13. A study on association and correlation of lip and finger print pattern analysis for gender identification

    Directory of Open Access Journals (Sweden)

    Surapaneni Ratheesh Kumar Nandan

    2015-01-01

    Conclusion: Lip print analysis is a challenging area in the personal identification during forensic dentistry examination. The study revealed the weaker correlation and approachable significance of lip and finger print pattern in gender identification. Future studies should be encouraged in the direction of software based identification for lip and finger print analysis in gender identification. Such studies may benefit this study pattern in more accurate way.

  14. Simulation of Grasping Prismatic Workpieces by a Pneumatically Driven 3-Finger Robotic Gripper

    Directory of Open Access Journals (Sweden)

    Calin-Octavian Miclosina

    2017-12-01

    Full Text Available The paper presents the 3D model of a robotic gripper and a way to determine the value of prehension force by using the SolidWorks software. A set of prismatic workpieces is considered, the contact force finger-workpiece being determined in SolidWorks Motion module for the most disadvantageous case - the heaviest workpiece, as well as von Mises stress that occurs in fingers gripper.

  15. Measurements Of Fingers Doses Of Staff Members In Nuclear Medicine Department

    International Nuclear Information System (INIS)

    AL LEHYANI, S.H.; SHOUSHA, H.A.; HASSAN, R.A.

    2009-01-01

    For some occupationally radiation exposed groups, the hands are more heavily exposed to ionizing radiation than the rest of the body. The Egyptian Atomic Energy Authority runs an extensive personal dosimetry service in Egypt, but finger doses have not been measured to a wide extent. In this study, the finger doses were measured for five different nuclear medicine staff occupational groups for which heavy irradiation of the hands was suspected. Finger doses were measured for nuclear medicine physicians, technologists, nurses and physicists. The nuclear medicine staff working with the radioactive materials wears two TLD dosimeters during the whole period, which lasted from 1 to 4 weeks. The staff performs their work on a regular basis throughout the month, and means annual doses were calculated for these groups. The doses to the fingers for the 99m Tc technologists and nurses of groups (2) and (3) were observed to be 30.24 ± 14.5 μSv/GBq (mean ± SD) and 30.37 ± 17.5 μSv/GBq, respectively. Similarly, the dose to the fingers for the 131 I technologists in group (5) was estimated to be 126.13 ± 38.2μSv/GBq. Finger doses for the physicians could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly but their doses were reported in millisieverts that accumulated in 1 week. The doses to the fingers of the physicist were 16.3±7.7 μSv/GBq. The maximum average finger dose in this study was found to be 2.8 mSv for the technologists handled therapeutic 131 I (group 5). It could be concluded that the maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y).

  16. Models of brachial to finger pulse wave distortion and pressure decrement.

    Science.gov (United States)

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  17. Touching Textured Surfaces: Cells in Somatosensory Cortex Respond Both to Finger Movement and to Surface Features

    Science.gov (United States)

    Darian-Smith, Ian; Sugitani, Michio; Heywood, John; Karita, Keishiro; Goodwin, Antony

    1982-11-01

    Single neurons in Brodmann's areas 3b and 1 of the macaque postcentral gyrus discharge when the monkey rubs the contralateral finger pads across a textured surface. Both the finger movement and the spatial pattern of the surface determine this discharge in each cell. The spatial features of the surface are represented unambiguously only in the responses of populations of these neurons, and not in the responses of the constituent cells.

  18. A STUDY OF RELATIVE CORRELATION BETWEEN THE PATTERN OF FINGER PRINTS AND LIP PRINTS

    OpenAIRE

    Murugan; Karikalan

    2014-01-01

    BACKGROUND AND OBJECTIVE: The use of conventional methods such as dactylography (study of finger prints) & cheiloscopy (study of lip prints) is of paramount importance, since personal identification by other means such as DNA analysis is sophisticated and not available in rural and developing countries. Fingerprint in its narrow sense is an impression left by the friction ridges of human fingers. The second prints of interest are lip prints. Studies of association between ...

  19. Finger Replantation in Sanglah General Hospital: Report of Five Cases and Literature Review

    OpenAIRE

    Agus Roy Rusly Hariantana Hamid; Gatot Triwono

    2016-01-01

    Background: Replantation is the prime treatment for amputated hands and fingers due to functional and aesthetic advantages. The absolute indications for replantation are amputations of the thumb, multiple fingers, trans metacarpal or hand, and any upper extremity in a child, regardless of the amputation level. A fingertip amputation distal to the insertion of the flexor digitorum superficialis (FDS) is also a good indication. Indications have been expanded to include amputation at nail level,...

  20. Digital artery perforator (DAP) flaps: modifications for fingertip and finger stump reconstruction.

    Science.gov (United States)

    Mitsunaga, Narushima; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Araki, Jun; Yamamoto, Yushuke; Yuhei, Otaki; Todokoro, Takeshi; Ishikawa, Shoichi; Eri, Uehara; Mundinger, Gerhard S

    2010-08-01

    Various fingertip reconstructions have been reported for situations where microsurgical finger replantation is impossible. One method is the digital artery perforator (DAP) flap. Herein we report 13 DAP flaps for fingertip and finger stump reconstruction following traumatic finger amputations, highlighting modifications to the originally described DAP flap. From October 1998 to December 2007, a total of 13 fingers (11 patients) underwent fingertip and finger stump reconstruction with modified DAP flaps following traumatic finger amputations. We performed six adipocutaneous flaps, three adipose-only flaps, two supercharged flaps and two extended flaps. Flap size ranged from 1.44 to 8 cm(2) (average 3.25 cm(2)). All flaps survived completely with the exception of partial skin necrosis in two cases. One of these cases required debridement and skin grafting. Our initial three cases used donor-site skin grafting. The donor site was closed primarily in the 10 subsequent cases. No patients showed postoperative hypersensitivity of repaired fingertips. Semmes-Weinstein (SW) test result for flaps including a digital nerve branch did not differ from those without (average 4.07 vs. 3.92). Modified DAP flaps allow for preservation of digital length, volume and finger function. They can be raised as adiposal-only flaps or extended flaps and supercharged through perforator-to-perforator anastomoses. The donor defect on the lateral pulp can be closed primarily or by skin grafting. For traumatic fingertip and finger stump reconstructions, DAP flaps deliver consistent aesthetic and functional results. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Divergent dislocation of the ring and little finger carpometacarpal joints--a rare injury pattern.

    LENUS (Irish Health Repository)

    Dillon, John

    2012-02-03

    Hand injuries due to longitudinal forces in the line of the metacarpals demonstrate unusual dislocation patterns. We describe a case of volar intra-articular fracture dislocation of the ring finger carpometacarpal joint in association with a pure dorsal dislocation of the little finger carpometacarpal joint. Open reduction supplemented with Kirschner wire fixation restored normal carpometacarpal joint anatomical relations and achieved an excellent clinical result.

  2. Backbone assignment of the little finger domain of a Y-family DNA polymerase.

    Science.gov (United States)

    Ma, Dejian; Fowler, Jason D; Suo, Zucai

    2011-10-01

    Sulfolobus solfataricus DNA polymerase IV (Dpo4), a prototype Y-family DNA polymerase, contains a unique little finger domain besides a catalytic core. Here, we report the chemical shift assignments for the backbone nitrogens, α and β carbons, and amide protons of the little finger domain of Dpo4. This work and our published backbone assignment for the catalytic core provide the basis for investigating the conformational dynamics of Dpo4 during catalysis using solution NMR spectroscopy.

  3. Reconstruction of fingers after electrical injury using lateral tarsal artery flap

    Directory of Open Access Journals (Sweden)

    Zhang MH

    2017-07-01

    Full Text Available Minghua Zhang, Mitao Huang, Pihong Zhang, Pengfei Liang, Licheng Ren, Jizhang Zeng, Jie Zhou, Xiong Liu, Tinghong Xie, Xiaoyuan Huang Department of Burns Reconstruction Surgery, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China Objective: Electrical injuries to the fingers account for the majority of total severe burns that occur each year. While several types of flaps have been used in covering finger defects, all have limitations or disadvantages. The purpose of this study was to introduce our clinical experiences of using the lateral tarsal artery (LTA flap to successfully restore fingers after electrical injury.Patients and methods: From 2005 to 2012, 10 patients with 14 severe electrical burns to their fingers, including six thumbs and four index and four middle fingers, were treated with LTA flap. The wound size ranged from 2.0×3.0 cm to 3.5×5.0 cm. The flap with free tendon graft was used to repair the tendon defect in four cases, free nerve graft was used to repair the feeling defect in two cases, and the flap with nerve was used to repair the feeling defect in two cases. All the patients were followed up for 3 months to 2 years.Results: All skin flaps adhered successfully and there were no complications. All patients were satisfied with the esthetic appearance and functional outcome of the finger reconstruction.Conclusion: LTA flap is a reliable method to restore fingers after severe electrical injuries. Keywords: electrical injuries to fingers, lateral tarsal artery flap

  4. Compensating Hand Function in Chronic Stroke Patients Through the Robotic Sixth Finger.

    Science.gov (United States)

    Salvietti, Gionata; Hussain, Irfan; Cioncoloni, David; Taddei, Sabrina; Rossi, Simone; Prattichizzo, Domenico

    2017-02-01

    A novel solution to compensate hand grasping abilities is proposed for chronic stroke patients. The goal is to provide the patients with a wearable robotic extra-finger that can be worn on the paretic forearm by means of an elastic band. The proposed prototype, the Robotic Sixth Finger, is a modular articulated device that can adapt its structure to the grasped object shape. The extra-finger and the paretic hand act like the two parts of a gripper cooperatively holding an object. We evaluated the feasibility of the approach with four chronic stroke patients performing a qualitative test, the Frenchay Arm Test. In this proof of concept study, the use of the Robotic Sixth Finger has increased the total score of the patients by two points in a five points scale. The subjects were able to perform the two grasping tasks included in the test that were not possible without the robotic extra-finger. Adding a robotic opposing finger is a very promising approach that can significantly improve the functional compensation of the chronic stroke patient during everyday life activities.

  5. Design of a Reconfigurable Robotic System for Flexoextension Fitted to Hand Fingers Size

    Directory of Open Access Journals (Sweden)

    J. Felipe Aguilar-Pereyra

    2016-01-01

    Full Text Available Due to the growing demand for assistance in rehabilitation therapies for hand movements, a robotic system is proposed to mobilize the hand fingers in flexion and extension exercises. The robotic system is composed by four, type slider-crank, mechanisms that have the ability to fit the user fingers length from the index to the little finger, through the adjustment of only one link for each mechanism. The trajectory developed by each mechanism corresponds to the natural flexoextension path of each finger. The amplitude of the rotations for metacarpophalangeal joint (MCP and proximal interphalangeal joint (PIP varies from 0 to 90° and the distal interphalangeal joint (DIP varies from 0 to 60°; the joint rotations are coordinated naturally. The four R-RRT mechanisms orientation allows a 15° abduction movement for index, ring, and little fingers. The kinematic analysis of this mechanism was developed in order to assure that the displacement speed and smooth acceleration into the desired range of motion and the simulation results are presented. The reconfiguration of mechanisms covers about 95% of hand sizes of a group of Mexican adult population. Maximum trajectory tracking error is less than 3% in full range of movement and it can be compensated by the additional rotation of finger joints without injury to the user.

  6. Cross-genera transferability of rice and finger millet genomic SSRs to barnyard millet (Echinochloa spp.).

    Science.gov (United States)

    Kalyana Babu, B; Sood, Salej; Kumar, Dinesh; Joshi, Anjeli; Pattanayak, A; Kant, Lakshmi; Upadhyaya, H D

    2018-02-01

    Barnyard millet ( Echinochloa spp.) is an important crop from nutritional point of view, nevertheless, the genetic information is very scarce. In the present investigation, rice and finger millet genomic SSRs were used for assessing cross transferability, identification of polymorphic markers, syntenic regions, genetic diversity and population structure analysis of barnyard millet genotypes. We observed 100% cross transferability for finger millet SSRs, of which 91% were polymorphic, while 71% of rice markers were cross transferable with 48% polymorphic out of them. Twenty-nine and sixteen highly polymorphic finger millet and rice SSRs yielded a mean of 4.3 and 3.38 alleles per locus in barnyard millet genotypes, respectively. The PIC values varied from 0.27 to 0.73 at an average of 0.54 for finger millet SSRs, whereas it was from 0.15 to 0.67 at an average of 0.44 for rice SSRs. High synteny was observed for markers related to panicle length, yield-related traits, spikelet fertility, plant height, root traits, leaf senescence, blast and brown plant hopper resistance. Although the rice SSRs located on chromosome 10 followed by chromosome 6 and 11 were found to be more transferable to barnyard millet, the finger millet SSRs were more polymorphic and transferable to barnyard millet genotypes. These SSR data of finger millet and rice individually as well as combined together grouped the 11 barnyard millet genotypes into 2 major clusters. The results of population structure analysis were similar to cluster analysis.

  7. Bioaccessible mineral content of malted finger millet (Eleusine coracana), wheat (Triticum aestivum), and barley (Hordeum vulgare).

    Science.gov (United States)

    Platel, Kalpana; Eipeson, Sushma W; Srinivasan, Krishnapura

    2010-07-14

    Malted grains are extensively used in weaning and geriatric foods. Malting generally improves the nutrient content and digestibility of foods. The present investigation examined the influence of malting of finger millet, wheat, and barley on the bioaccessibility of iron, zinc, calcium, copper, and manganese. Malting increased the bioaccessibility of iron by >3-fold from the two varieties of finger millet and by >2-fold from wheat, whereas such a beneficial influence was not seen in barley. The bioaccessibility of zinc from wheat and barley increased to an extent of 234 and 100%, respectively, as a result of malting. However, malting reduced the bioaccessibility of zinc from finger millet. Malting marginally increased the bioaccessibility of calcium from white finger millet and wheat. Whereas malting did not exert any influence on bioaccessibility of copper from finger millet and wheat, it significantly decreased (75%) the same from barley. Malting did increase the bioaccessibility of manganese from brown finger millet (17%) and wheat (42%). Thus, malting could be an appropriate food-based strategy to derive iron and other minerals maximally from food grains.

  8. Finger-Shaped GelForce: Sensor for Measuring Surface Traction Fields for Robotic Hand.

    Science.gov (United States)

    Sato, K; Kamiyama, K; Kawakami, N; Tachi, S

    2010-01-01

    It is believed that the use of haptic sensors to measure the magnitude, direction, and distribution of a force will enable a robotic hand to perform dexterous operations. Therefore, we develop a new type of finger-shaped haptic sensor using GelForce technology. GelForce is a vision-based sensor that can be used to measure the distribution of force vectors, or surface traction fields. The simple structure of the GelForce enables us to develop a compact finger-shaped GelForce for the robotic hand. GelForce that is developed on the basis of an elastic theory can be used to calculate surface traction fields using a conversion equation. However, this conversion equation cannot be analytically solved when the elastic body of the sensor has a complicated shape such as the shape of a finger. Therefore, we propose an observational method and construct a prototype of the finger-shaped GelForce. By using this prototype, we evaluate the basic performance of the finger-shaped GelForce. Then, we conduct a field test by performing grasping operations using a robotic hand. The results of this test show that using the observational method, the finger-shaped GelForce can be successfully used in a robotic hand.

  9. Arrhythmokinesis is evident during unimanual not bimanual finger tapping in Parkinson's disease.

    Science.gov (United States)

    Trager, Megan H; Velisar, Anca; Koop, Mandy Miller; Shreve, Lauren; Quinn, Emma; Bronte-Stewart, Helen

    2015-01-01

    Arrhythmokinesis, the variability in repetitive movements, is a fundamental feature of Parkinson's disease (PD). We hypothesized that unimanual repetitive alternating finger tapping (AFT) would reveal more arrhythmokinesis compared to bimanual single finger alternating hand tapping (SFT), in PD. The variability of inter-strike interval (CVISI) and of amplitude (CVAMP) during AFT and SFT were measured on an engineered, MRI-compatible keyboard in sixteen PD subjects off medication and in twenty-four age-matched controls. The CVISI and CVAMP of the more affected (MA) and less affected (LA) sides in PD subjects were greater during AFT than SFT (P tapping brings out more arrhythmokinesis compared to bimanual, single finger tapping in PDs but not in controls. Arrhythmokinesis during unimanual, alternating finger tapping captured a significant difference between both the MA and LA hands of PD subjects and controls, whereas that during a bimanual, single finger tapping task only distinguished between the MA hand and controls. Arrhythmokinesis underlies freezing of gait and may also underlie the freezing behavior documented in fine motor control if studied using a unimanual alternating finger tapping task.

  10. Quantitative assessment of finger tapping characteristics in mild cognitive impairment, Alzheimer's disease, and Parkinson's disease.

    Science.gov (United States)

    Roalf, David R; Rupert, Petra; Mechanic-Hamilton, Dawn; Brennan, Laura; Duda, John E; Weintraub, Daniel; Trojanowski, John Q; Wolk, David; Moberg, Paul J

    2018-06-01

    Fine motor impairments are common in neurodegenerative disorders, yet standardized, quantitative measurements of motor abilities are uncommonly used in neurological practice. Thus, understanding and comparing fine motor abilities across disorders have been limited. The current study compared differences in finger tapping, inter-tap interval, and variability in Alzheimer's disease (AD), Parkinson's disease (PD), mild cognitive impairment (MCI), and healthy older adults (HOA). Finger tapping was measured using a highly sensitive light-diode finger tapper. Total number of finger taps, inter-tap interval, and intra-individual variability (IIV) of finger tapping was measured and compared in AD (n = 131), PD (n = 63), MCI (n = 46), and HOA (n = 62), controlling for age and sex. All patient groups had fine motor impairments relative to HOA. AD and MCI groups produced fewer taps with longer inter-tap interval and higher IIV compared to HOA. The PD group, however, produced more taps with shorter inter-tap interval and higher IIV compared to HOA. Disease-specific changes in fine motor function occur in the most common neurodegenerative diseases. The findings suggest that alterations in finger tapping patterns are common in AD, MCI, and PD. In addition, the present results underscore the importance of motor dysfunction even in neurodegenerative disorders without primary motor symptoms.

  11. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw.

    Science.gov (United States)

    Cox, Christopher; Earp, Brandon E; Floyd, W Emerson; Blazar, Philip E

    2014-01-01

    To study the results of using a small, headless compression screw (AcuTwist) for thumb interphalangeal (IP) joint and finger distal interphalangeal (DIP) joint arthrodeses. Between November 2007 and January 2012, 48 primary arthrodeses of the thumb IP joint or DIP joint in the other digits were performed in 29 consecutive patients with AcuTwist devices. Indications for arthrodesis included 19 cases of osteoarthritis in 25 fingers, 3 cases of lupus in 9 fingers, 2 cases of post-traumatic osteoarthritis in 2 fingers, and 1 case and finger each of acute trauma, neuromuscular disorder, postinfectious osteoarthritis, boutonniere deformity, and Dupuytren contracture. Charts were reviewed for clinical data, and radiographs were assessed for alignment and healing. Age averaged 59 years and follow-up averaged 12 months (range, 2-50 mo). Union occurred in 43 out of 46 fingers (94%). There were no cases of nail deformity, wound complications, tip hypersensitivity, or clinically notable malalignment. Three arthrodeses failed to fuse, including 2 asymptomatic nonunions and 1 fixation loss requiring revision with autograft. The complication rate was 9%. Distal digital joint arthrodesis with the AcuTwist resulted in a fusion rate of 94% with a complication rate of 9%. Our rate of fusion compares favorably with prior series using other methods of fixation. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Rate effects on timing, key velocity, and finger kinematics in piano performance.

    Science.gov (United States)

    Bella, Simone Dalla; Palmer, Caroline

    2011-01-01

    We examined the effect of rate on finger kinematics in goal-directed actions of pianists. In addition, we evaluated whether movement kinematics can be treated as an indicator of personal identity. Pianists' finger movements were recorded with a motion capture system while they performed melodies from memory at different rates. Pianists' peak finger heights above the keys preceding keystrokes increased as tempo increased, and were attained about one tone before keypress. These rate effects were not simply due to a strategy to increase key velocity (associated with tone intensity) of the corresponding keystroke. Greater finger heights may compensate via greater tactile feedback for a speed-accuracy tradeoff that underlies the tendency toward larger temporal variability at faster tempi. This would allow pianists to maintain high temporal accuracy when playing at fast rates. In addition, finger velocity and accelerations as pianists' fingers approached keys were sufficiently unique to allow pianists' identification with a neural-network classifier. Classification success was higher in pianists with more extensive musical training. Pianists' movement "signatures" may reflect unique goal-directed movement kinematic patterns, leading to individualistic sound.

  13. Finger crease pattern recognition using Legendre moments and principal component analysis

    Science.gov (United States)

    Luo, Rongfang; Lin, Tusheng

    2007-03-01

    The finger joint lines defined as finger creases and its distribution can identify a person. In this paper, we propose a new finger crease pattern recognition method based on Legendre moments and principal component analysis (PCA). After obtaining the region of interest (ROI) for each finger image in the pre-processing stage, Legendre moments under Radon transform are applied to construct a moment feature matrix from the ROI, which greatly decreases the dimensionality of ROI and can represent principal components of the finger creases quite well. Then, an approach to finger crease pattern recognition is designed based on Karhunen-Loeve (K-L) transform. The method applies PCA to a moment feature matrix rather than the original image matrix to achieve the feature vector. The proposed method has been tested on a database of 824 images from 103 individuals using the nearest neighbor classifier. The accuracy up to 98.584% has been obtained when using 4 samples per class for training. The experimental results demonstrate that our proposed approach is feasible and effective in biometrics.

  14. Finger vein identification using fuzzy-based k-nearest centroid neighbor classifier

    Science.gov (United States)

    Rosdi, Bakhtiar Affendi; Jaafar, Haryati; Ramli, Dzati Athiar

    2015-02-01

    In this paper, a new approach for personal identification using finger vein image is presented. Finger vein is an emerging type of biometrics that attracts attention of researchers in biometrics area. As compared to other biometric traits such as face, fingerprint and iris, finger vein is more secured and hard to counterfeit since the features are inside the human body. So far, most of the researchers focus on how to extract robust features from the captured vein images. Not much research was conducted on the classification of the extracted features. In this paper, a new classifier called fuzzy-based k-nearest centroid neighbor (FkNCN) is applied to classify the finger vein image. The proposed FkNCN employs a surrounding rule to obtain the k-nearest centroid neighbors based on the spatial distributions of the training images and their distance to the test image. Then, the fuzzy membership function is utilized to assign the test image to the class which is frequently represented by the k-nearest centroid neighbors. Experimental evaluation using our own database which was collected from 492 fingers shows that the proposed FkNCN has better performance than the k-nearest neighbor, k-nearest-centroid neighbor and fuzzy-based-k-nearest neighbor classifiers. This shows that the proposed classifier is able to identify the finger vein image effectively.

  15. Design of a Reconfigurable Robotic System for Flexoextension Fitted to Hand Fingers Size.

    Science.gov (United States)

    Aguilar-Pereyra, J Felipe; Castillo-Castaneda, Eduardo

    2016-01-01

    Due to the growing demand for assistance in rehabilitation therapies for hand movements, a robotic system is proposed to mobilize the hand fingers in flexion and extension exercises. The robotic system is composed by four, type slider-crank, mechanisms that have the ability to fit the user fingers length from the index to the little finger, through the adjustment of only one link for each mechanism. The trajectory developed by each mechanism corresponds to the natural flexoextension path of each finger. The amplitude of the rotations for metacarpophalangeal joint (MCP) and proximal interphalangeal joint (PIP) varies from 0 to 90° and the distal interphalangeal joint (DIP) varies from 0 to 60°; the joint rotations are coordinated naturally. The four R-RRT mechanisms orientation allows a 15° abduction movement for index, ring, and little fingers. The kinematic analysis of this mechanism was developed in order to assure that the displacement speed and smooth acceleration into the desired range of motion and the simulation results are presented. The reconfiguration of mechanisms covers about 95% of hand sizes of a group of Mexican adult population. Maximum trajectory tracking error is less than 3% in full range of movement and it can be compensated by the additional rotation of finger joints without injury to the user.

  16. Finger Vein Recognition Using Optimal Partitioning Uniform Rotation Invariant LBP Descriptor

    Directory of Open Access Journals (Sweden)

    Bang Chao Liu

    2016-01-01

    Full Text Available As a promising biometric system, finger vein identification has been studied widely and many relevant researches have been proposed. However, it is hard to extract a satisfied finger vein pattern due to the various vein thickness, illumination, low contrast region, and noise existing. And most of the feature extraction algorithms rely on high-quality finger vein database and take a long time for a large dimensional feature vector. In this paper, we proposed two block selection methods which are based on the estimate of the amount of information in each block and the contribution of block location by looking at recognition rate of each block position to reduce feature extraction time and matching time. The specific approach is to find out some local finger vein areas with low-quality and noise, which will be useless for feature description. Local binary pattern (LBP descriptors are proposed to extract the finger vein pattern feature. Two finger vein databases are taken to test our algorithm performance. Experimental results show that proposed block selection algorithms can reduce the feature vector dimensionality in a large extent.

  17. Analysis of a 12-Finger Rod Drop using RETRAN/MASTER Code System for APR1400

    International Nuclear Information System (INIS)

    Yu, Keuk Jong; You, Sung Chang; Kim, Han Gon

    2009-01-01

    The Optimized Power Reactor 1000 (OPR1000) has 4-finger and 12-finger Control Element Assemblies (CEAs). When the 12-finger CEA is dropped, Core Protection Calculator System (CPCS) shuts down the reactor to prevent fuel damage that could occur from the sudden reactor power peaking. By contrast, the improved CPCS of Advanced Power Reactor 1400 (APR1400), which has systems similar to those of the OPR1000, decreases reactor power rapidly using its Reactor Power Cutback System (RPCS) to avoid unwanted reactor trips caused by the CPCS during a 12- finger CEA drop event. RETRAN is a best-estimate code for transient analysis of Non-LOCA. The RETRAN control logic, which includes the function of reducing reactor power during a 12-Finger CEA drop, has been developed for the APR1400. A MATRAN program has also been developed. MATRAN is the interface program for realtime processing to connect RETRAN with MASTER code which is a nuclear analysis and design code. MATRAN supplies adequate feedback reactivities from the MASTER code to RETRAN code. The purpose of this study is to analyze the behavior of a nuclear reactor core and its primary system using conventional RETRAN analysis procedure and MATRAN program analysis procedure during a 12- finger CEA drop. In addition, the axial power distribution and Axial Shape Index (ASI) are produced by the MATRAN program and they are confirmed as within operation limits

  18. Non-destructive examination of the bonding interface in DEMO divertor fingers

    International Nuclear Information System (INIS)

    Richou, Marianne; Missirlian, Marc; Vignal, Nicolas; Cantone, Vincent; Hernandez, Caroline; Norajitra, Prachai; Spatafora, Luigi

    2013-01-01

    Highlights: • SATIR tests on DEMO divertor fingers (integrating or not He cooling system). • Millimeter size artificial defects were manufactured. • Detectability of millimeter size artificial defects was evaluated. • SATIR can detect defect in DEMO divertor fingers. • Simulations are well correlated to SATIR tests. -- Abstract: Plasma facing components (PFCs) with tungsten (W) armor materials for DEMO divertor require a high heat flux removal capability (at least 10 MW/m 2 in steady-state conditions). The reference divertor PFC concept is a finger with a tungsten tile as a protection and sacrificial layer brazed to a thimble made of tungsten alloy W – 1% La 2 O 3 (WL10). Defects may be located at the W thimble to W tile interface. As the number of fingers is considerable (>250,000), it is then a major issue to develop a reliable control procedure in order to control with a non-destructive examination the fabrication processes. The feasibility for detecting defect with infrared thermography SATIR test bed is presented. SATIR is based on the heat transient method and is used as an inspection tool in order to assess component heat transfer capability. SATIR tests were performed on fingers integrating or not the complex He cooling system (steel cartridge with jet holes). Millimeter size artificial defects were manufactured and their detectability was evaluated. Results of this study demonstrate that the SATIR method can be considered as a relevant non-destructive technique examination for the defect detection of DEMO divertor fingers

  19. Use of preputial skin for coverage of post-burn contractures of fingers in children

    Directory of Open Access Journals (Sweden)

    Mohammed I Zaroo

    2011-01-01

    Full Text Available Objective: Hand burns are common injuries. Children frequently sustain burn injuries, especially to their hands. Contractures are a common sequel of severe burns around joints. The prepuce, or foreskin, has been used as a skin graft for a number of indications. We conducted this study to evaluate the feasibility of utilising the preputial skin for the management of post-burn contractures of fingers in uncircumcised male children. Materials and Methods: Preputial skin was used for the coverage of released contractures of fingers in 12 patients aged 2-6 years. The aetiology of burns was "Kangri" burn in eight patients and scalding in four patients. Six patients had contracture in two fingers, four patients in one finger, and two patients had contractures in three fingers. Results: None of the patients had graft loss, and all the wounds healed within 2 weeks. All patients had complete release of contractures without any recurrence. Hyperpigmentation of the grafts was observed over a period of time, which was well accepted by the parents. Conclusions: Preputial skin can be used successfully for male children with mild-to-moderate contractures of 2-3 fingers for restoration of the hand function, minimal donor site morbidity.

  20. Finger Replantation in Sanglah General Hospital: Report of Five Cases and Literature Review

    Directory of Open Access Journals (Sweden)

    Agus Roy Rusly Hariantana Hamid

    2016-11-01

    Full Text Available Background: Replantation is the prime treatment for amputated hands and fingers due to functional and aesthetic advantages. The absolute indications for replantation are amputations of the thumb, multiple fingers, trans metacarpal or hand, and any upper extremity in a child, regardless of the amputation level. A fingertip amputation distal to the insertion of the flexor digitorum superficialis (FDS is also a good indication. Indications have been expanded to include amputation at nail level, and when there is a request from the patient, replantation is attempted even for a single finger amputation regardless of the amputation level. Based on the mechanism of injury, a clean-cut sharp amputation is more likely replanted compare to a crush and avulsion injuries. With a proper management of the amputated finger, replantation can be attempted even after 24 hours. This report was written to provide examples of finger replantation cases and the measures that can be taken in a resource-limited hospital in order to conduct a replantation. Case Series: We reported five out of nine digital replantation cases in Sanglah General Hospital between January and July 2014. Two patients were a six and an eleven years old boys who accidentally cut their finger while playing, the rests were male labors between 20-30 years old whose amputations due to machine injuries. Result: A 100% replant survival was achieved. After a period of follow up with occupational therapy, all patients regain good functional and cosmetic results. 

  1. Ribosomal DNA variation in finger millet and wild species of Eleusine (Poaceae).

    Science.gov (United States)

    Hilu, K W; Johnson, J L

    1992-04-01

    Finger millet is an important cereal crop in the semi-arid regions of Africa and India. The crop belongs to the grass genus Eleusine, which includes nine annual and perennial species native to Africa except for the New World species E. tristachya. Ribosomal DNA (rDNA) variation in finger millet and related wild species was used to provide information on the origin of the genomes of this tetraploid crop and point out genetic relationships of the crop to other species in the genus. The restriction endonucleases used revealed a lack of variability in the rDNA spacer region in domesticated finger millet. All the rDNA variants of the crop were found in the proposed direct tetraploid ancestor, E. coracana subsp. africana. Wild and domesticated finger millet displayed the phenotypes found in diploid E. indica. Diploid Eleusine tristachya showed some similarity to the crop in some restriction sites. The remaining species were quite distinct in rDNA fragment patterns. The study supports the direct origin of finger millet from subspecies africana shows E. indica to be one of the genome donors of the crop, and demonstrates that none of the other species examined could have donated the second genome of the crop. The rDNA data raise the possibility that wild and domesticated finger millet could have originated as infraspecific polyploid hybrids from different varieties of E. indica.

  2. Identification of the ``a'' Genome of Finger Millet Using Chloroplast DNA

    Science.gov (United States)

    Hilu, K. W.

    1988-01-01

    Finger millet (Eleusine corocana subsp. coracana), an important cereal in East Africa and India, is a tetraploid species with unknown genomic components. A recent cytogenetic study confirmed the direct origin of this millet from the tetraploid E. coracana subsp. africana but questioned Eleusine indica as a genomic donor. Chloroplast (ct) DNA sequence analysis using restriction fragment pattern was used to examine the phylogenetic relationships between E. coracana subsp. coracana (domesticated finger millet), E. coracana subspecies africana (wild finger millet), and E. indica. Eleusine tristachya was included since it is the only other annual diploid species in the genus with a basic chromosome number of x = 9 like finger millet. Eight of the ten restriction endonucleases used had 16 to over 30 restriction sites per genome and were informative. E. coracana subsp. coracana and subsp. africana and E. indica were identical in all the restriction sites surveyed, while the ct genome of E. tristachya differed consistently by at least one mutational event for each restriction enzyme surveyed. This random survey of the ct genomes of these species points out E. indica as one of the genome donors (maternal genome donor) of domesticated finger millet contrary to a previous cytogenetic study. The data also substantiate E. coracana subsp. africana as the progenitor of domesticated finger millet. The disparity between the cytogenetic and the molecular approaches is discussed in light of the problems associated with chromosome pairing and polyploidy. PMID:8608927

  3. Identification of the "A" genome of finger millet using chloroplast DNA.

    Science.gov (United States)

    Hilu, K W

    1988-01-01

    Finger millet (Eleusine corocana subsp. coracana), an important cereal in East Africa and India, is a tetraploid species with unknown genomic components. A recent cytogenetic study confirmed the direct origin of this millet from the tetraploid E. coracana subsp. africana but questioned Eleusine indica as a genomic donor. Chloroplast (ct) DNA sequence analysis using restriction fragment pattern was used to examine the phylogenetic relationships between E. coracana subsp. coracana (domesticated finger millet), E. coracana subspecies africana (wild finger millet), and E. indica. Eleusine tristachya was included since it is the only other annual diploid species in the genus with a basic chromosome number of x = 9 like finger millet. Eight of the ten restriction endonucleases used had 16 to over 30 restriction sites per genome and were informative. E. coracana subsp. coracana and subsp. africana and E. indica were identical in all the restriction sites surveyed, while the ct genome of E, tristachya differed consistently by at least one mutational event for each restriction enzyme surveyed. This random survey of the ct genomes of these species points out E. indica as one of the genome donors (maternal genome donor) of domesticated finger millet contrary to a previous cytogenetic study. The data also substantiate E. coracana subsp. africana as the progenitor of domesticated finger millet. The disparity between the cytogenetic and the molecular approaches is discussed in light of the problems associated with chromosome pairing and polyploidy.

  4. Personal recognition using finger knuckle shape oriented features and texture analysis

    Directory of Open Access Journals (Sweden)

    K. Usha

    2016-10-01

    Full Text Available Finger knuckle print is considered as one of the emerging hand biometric traits due to its potentiality toward the identification of individuals. This paper contributes a new method for personal recognition using finger knuckle print based on two approaches namely, geometric and texture analyses. In the first approach, the shape oriented features of the finger knuckle print are extracted by means of angular geometric analysis and then integrated to achieve better precision rate. Whereas, the knuckle texture feature analysis is carried out by means of multi-resolution transform known as Curvelet transform. This Curvelet transform has the ability to approximate curved singularities with minimum number of Curvelet coefficients. Since, finger knuckle patterns mainly consist of lines and curves, Curvelet transform is highly suitable for its representation. Further, the Curvelet transform decomposes the finger knuckle image into Curvelet sub-bands which are termed as ‘Curvelet knuckle’. Finally, principle component analysis is applied on each Curvelet knuckle for extracting its feature vector through the covariance matrix derived from their Curvelet coefficients. Extensive experiments were conducted using PolyU database and IIT finger knuckle database. The experimental results confirm that, our proposed method shows a high recognition rate of 98.72% with lower false acceptance rate of 0.06%.

  5. Rate effects on timing, key velocity, and finger kinematics in piano performance.

    Directory of Open Access Journals (Sweden)

    Simone Dalla Bella

    Full Text Available We examined the effect of rate on finger kinematics in goal-directed actions of pianists. In addition, we evaluated whether movement kinematics can be treated as an indicator of personal identity. Pianists' finger movements were recorded with a motion capture system while they performed melodies from memory at different rates. Pianists' peak finger heights above the keys preceding keystrokes increased as tempo increased, and were attained about one tone before keypress. These rate effects were not simply due to a strategy to increase key velocity (associated with tone intensity of the corresponding keystroke. Greater finger heights may compensate via greater tactile feedback for a speed-accuracy tradeoff that underlies the tendency toward larger temporal variability at faster tempi. This would allow pianists to maintain high temporal accuracy when playing at fast rates. In addition, finger velocity and accelerations as pianists' fingers approached keys were sufficiently unique to allow pianists' identification with a neural-network classifier. Classification success was higher in pianists with more extensive musical training. Pianists' movement "signatures" may reflect unique goal-directed movement kinematic patterns, leading to individualistic sound.

  6. Reconstruction of gastric slow wave from finger photoplethysmographic signal using radial basis function neural network.

    Science.gov (United States)

    Mohamed Yacin, S; Srinivasa Chakravarthy, V; Manivannan, M

    2011-11-01

    Extraction of extra-cardiac information from photoplethysmography (PPG) signal is a challenging research problem with significant clinical applications. In this study, radial basis function neural network (RBFNN) is used to reconstruct the gastric myoelectric activity (GMA) slow wave from finger PPG signal. Finger PPG and GMA (measured using Electrogastrogram, EGG) signals were acquired simultaneously at the sampling rate of 100 Hz from ten healthy subjects. Discrete wavelet transform (DWT) was used to extract slow wave (0-0.1953 Hz) component from the finger PPG signal; this slow wave PPG was used to reconstruct EGG. A RBFNN is trained on signals obtained from six subjects in both fasting and postprandial conditions. The trained network is tested on data obtained from the remaining four subjects. In the earlier study, we have shown the presence of GMA information in finger PPG signal using DWT and cross-correlation method. In this study, we explicitly reconstruct gastric slow wave from finger PPG signal by the proposed RBFNN-based method. It was found that the network-reconstructed slow wave provided significantly higher (P wave than the correlation obtained (≈0.7) between the PPG slow wave from DWT and the EEG slow wave. Our results showed that a simple finger PPG signal can be used to reconstruct gastric slow wave using RBFNN method.

  7. The neural substrates of impaired finger tapping regularity after stroke.

    Science.gov (United States)

    Calautti, Cinzia; Jones, P Simon; Guincestre, Jean-Yves; Naccarato, Marcello; Sharma, Nikhil; Day, Diana J; Carpenter, T Adrian; Warburton, Elizabeth A; Baron, Jean-Claude

    2010-03-01

    Not only finger tapping speed, but also tapping regularity can be impaired after stroke, contributing to reduced dexterity. The neural substrates of impaired tapping regularity after stroke are unknown. Previous work suggests damage to the dorsal premotor cortex (PMd) and prefrontal cortex (PFCx) affects externally-cued hand movement. We tested the hypothesis that these two areas are involved in impaired post-stroke tapping regularity. In 19 right-handed patients (15 men/4 women; age 45-80 years; purely subcortical in 16) partially to fully recovered from hemiparetic stroke, tri-axial accelerometric quantitative assessment of tapping regularity and BOLD fMRI were obtained during fixed-rate auditory-cued index-thumb tapping, in a single session 10-230 days after stroke. A strong random-effect correlation between tapping regularity index and fMRI signal was found in contralesional PMd such that the worse the regularity the stronger the activation. A significant correlation in the opposite direction was also present within contralesional PFCx. Both correlations were maintained if maximal index tapping speed, degree of paresis and time since stroke were added as potential confounds. Thus, the contralesional PMd and PFCx appear to be involved in the impaired ability of stroke patients to fingertap in pace with external cues. The findings for PMd are consistent with repetitive TMS investigations in stroke suggesting a role for this area in affected-hand movement timing. The inverse relationship with tapping regularity observed for the PFCx and the PMd suggests these two anatomically-connected areas negatively co-operate. These findings have implications for understanding the disruption and reorganization of the motor systems after stroke. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  8. Effect of meaning on apraxic finger imitation deficits.

    Science.gov (United States)

    Achilles, E I S; Fink, G R; Fischer, M H; Dovern, A; Held, A; Timpert, D C; Schroeter, C; Schuetz, K; Kloetzsch, C; Weiss, P H

    2016-02-01

    Apraxia typically results from left-hemispheric (LH), but also from right-hemispheric (RH) stroke, and often impairs gesture imitation. Especially in LH stroke, it is important to differentiate apraxia-induced gesture imitation deficits from those due to co-morbid aphasia and associated semantic deficits, possibly influencing the imitation of meaningful (MF) gestures. To explore this issue, we first investigated if the 10 supposedly meaningless (ML) gestures of a widely used finger imitation test really carry no meaning, or if the test also contains MF gestures, by asking healthy subjects (n=45) to classify these gestures as MF or ML. Most healthy subjects (98%) classified three of the 10 gestures as clearly MF. Only two gestures were considered predominantly ML. We next assessed how imitation in stroke patients (255 LH, 113 RH stroke) is influenced by gesture meaning and how aphasia influences imitation of LH stroke patients (n=208). All patients and especially patients with imitation deficits (17% of LH, 27% of RH stroke patients) imitated MF gestures significantly better than ML gestures. Importantly, meaningfulness-scores of all 10 gestures significantly predicted imitation scores of patients with imitation deficits. Furthermore, especially in LH stroke patients with imitation deficits, the severity of aphasia significantly influenced the imitation of MF, but not ML gestures. Our findings in a large patient cohort support current cognitive models of imitation and strongly suggest that ML gestures are particularly sensitive to detect imitation deficits while minimising confounding effects of aphasia which affect the imitation of MF gestures in LH stroke patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. [FTIR study on the finger nail with carcinoma of nasopharynx].

    Science.gov (United States)

    Dong, Qin; Liu, Gang; Liu, Tian-hui

    2004-12-01

    Finger nails from twenty normal people and three with carcinoma of nasopharynx were studied by Fourier Transform Infrared (FTIR) technique. The results showed that there are obvious differences between FTIR spectra of them in spectral parameters such as frequency, intensity and band shape etc. The most striking differences in the spectra were observed in the change of amide II, the disappearance of delta(s) (CH3) peak, and at 874.0 cm(-1) whether appeared an absorption peak. The changes involving the phosphate symmetric stretching nu(s, PO2-) and asynmmetric stretching nu(as, PO2-) modes, the CH3 and CH2 groups stretching (v(s, CH2), nu(as, CH3)) bending (delta (CH3)) modes and the C-O stretching nu (C-O) mode were discussed. In addition, the changes of structure of hydrogen-bonding of nucleic acid and cell proteins and the packing and the conformational structure of the membrane lipids were analysed. The average wave number of band of nu(s) (PO2-) shifted from 1080.0 to 1077.6 cm(-1) and that of nu(as) (PO2-) shifted from 1239.4 to 1238.4 cm(-1), which indicated that the degree of hydrogen-bonding formed by oxygen atom of the phosphodiester groups of nucleic acids was weakened. The average wave number of band of delta (CH2) of membrane lipids shifted from 1453.1 to 1453.7 cm(-1), and its peak intensity was slightly enhanced, which suggested that the conformational structure of the methylene chains of membrane lipids is more disordered than in normal nail.

  10. Structural and dynamical characterization of the Miz-1 zinc fingers 5-8 by solution-state NMR

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, David; Bedard, Mikaeel; Bilodeau, Josee; Lavigne, Pierre, E-mail: pierre.lavigne@usherbrooke.ca [Universite de Sherbrooke, Departement de Biochimie, Faculte de Medecine et des Sciences de la Sante, Institut de Pharmacologie de Sherbrooke (Canada)

    2013-10-15

    Myc-interacting zinc finger protein-1 (Miz-1) is a BTB/POZ transcription factor that activates the transcription of cytostatic genes, such as p15{sup INK4B} or p21{sup CIP1}. The C-terminus of Miz-1 contains 13 consensus C{sub 2}H{sub 2} zinc finger domains (ZF). ZFs 1-4 have been shown to interact with SMAD3/4, while the remaining ZFs are expected to bind the promoters of target genes. We have noted unusual features in ZF 5 and the linker between ZFs 5 and 6. Indeed, a glutamate is found instead of the conserved basic residue two positions before the second zinc-coordinating histidine on the ZF 5 helix, and the linker sequence is DTDKE in place of the classical TGEKP sequence. In a canonical {beta}{beta}{alpha} fold, such unusual primary structure elements should cause severe electrostatic repulsions. In this context, we have characterized the structure and the dynamics of a Miz-1 construct comprising ZFs 5-8 (Miz 5-8) by solution-state NMR. Whilst ZFs 5, 7 and 8 were shown to adopt the classical {beta}{beta}{alpha} fold for C{sub 2}H{sub 2} ZFs, the number of long-range NOEs was insufficient to define a classical fold for ZF 6. We show by using {sup 15}N-relaxation dispersion experiments that this lack of NOEs is due to the presence of extensive motions on the {mu}s-ms timescale. Since this negatively charged region would have to be located near the phosphodiester backbone in a DNA complex, we propose that in addition to promoting conformational searches, it could serve as a hinge region to keep ZFs 1-4 away from DNA.

  11. Anatomy of the fingers in MR imaging using a high resolution surface coil; Die Anatomie der Finger in der MRT unter Anwendung einer Hochaufloesungsspule

    Energy Technology Data Exchange (ETDEWEB)

    Maeurer, J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Mueller, H.F. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Lemke, A.J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Requardt, R. [Siemens AG, Erlangen (Germany); Stein, I. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Langer, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)

    1994-12-31

    MR-images of the fingers of twenty healthy volunteers were obtained at a 1,5-T whole-body system with a high resolution coil. Additionally, the fingers of two formalin-fixed anatomical specismen were imaged, fronzen and then subsequently sectioned for anatomic correlation. Measurements were recorded with a slice thickness of 2 mm. A 256x256 matrix and a 2,5 cam fiel of view (FOV) were used resulting in a pixel size of 0,01 mm{sup 2}. Based on the excellent depiction of anatomic detail and contrast resolution high resolution MRI of the fingers enabled identification of osseous and cartilaginous structures, as well as delineation of tendons, ligaments blood-vessels and dermal layers. (orig.) [Deutsch] An einem 1,5-T-Ganzkoerpertomographen wurden die Finger von 20 gesunden Probanden mit einer Hochaufloesungsspule zur Darstellung der Anatomie untersucht. Zum Vergleich erfolgte die Abbildung der anatomischen Strukturen an zwei formol- und alkoholfixierten Leichepraeparaten der Hand mittels MRT. Im Anschluss wurden die untersuchten Regionen am tiefgefrorenen Praeparat mit einer Bandsaege nachgeschnitten. Die MR-Messungen wurden mit einer Schichtdicke von 3 mm, einem Field of View (FOV) von 25 mm und einer Matrix von 256x256 Pixel durchgefuehrt. Die daraus resultierende Pixelgroesse betrug 0,01 mm{sup 2}. Der Weichteilkontrast und die hohe Ortsaufloesung ermoeglichten die Identifikation von Knochen- und Knorpelstrukturen sowie die Abgrenzung von Sehnen, Baendern, Blutgefaessen und Hautschichten. (orig.)

  12. Conservation, diversification and expansion of C2H2 zinc finger proteins in the Arabidopsis thaliana genome

    Directory of Open Access Journals (Sweden)

    Böhm Siegfried

    2004-07-01

    Full Text Available Background The classical C2H2 zinc finger domain is involved in a wide range of functions and can bind to DNA, RNA and proteins. The comparison of zinc finger proteins in several eukaryotes has shown that there is a lot of lineage specific diversification and expansion. Although the number of characterized plant proteins that carry the classical C2H2 zinc finger motifs is growing, a systematic classification and analysis of a plant genome zinc finger gene set is lacking. Results We found through in silico analysis 176 zinc finger proteins in Arabidopsis thaliana that hence constitute the most abundant family of putative transcriptional regulators in this plant. Only a minority of 33 A. thaliana zinc finger proteins are conserved in other eukaryotes. In contrast, the majority of these proteins (81% are plant specific. They are derived from extensive duplication events and form expanded families. We assigned the proteins to different subgroups and families and focused specifically on the two largest and evolutionarily youngest families (A1 and C1 that are suggested to be primarily involved in transcriptional regulation. The newly defined family A1 (24 members comprises proteins with tandemly arranged zinc finger domains. Family C1 (64 members, earlier described as the EPF-family in Petunia, comprises proteins with one isolated or two to five dispersed fingers and a mostly invariant QALGGH motif in the zinc finger helices. Based on the amino acid pattern in these helices we could describe five different signature sequences prevalent in C1 zinc finger domains. We also found a number of non-finger domains that are conserved in these families. Conclusions Our analysis of the few evolutionarily conserved zinc finger proteins of A. thaliana suggests that most of them could be involved in ancient biological processes like RNA metabolism and chromatin-remodeling. In contrast, the majority of the unique A. thaliana zinc finger proteins are known or

  13. Experimental Evaluation of a Braille-Reading-Inspired Finger Motion Adaptive Algorithm.

    Science.gov (United States)

    Ulusoy, Melda; Sipahi, Rifat

    2016-01-01

    Braille reading is a complex process involving intricate finger-motion patterns and finger-rubbing actions across Braille letters for the stimulation of appropriate nerves. Although Braille reading is performed by smoothly moving the finger from left-to-right, research shows that even fluent reading requires right-to-left movements of the finger, known as "reversal". Reversals are crucial as they not only enhance stimulation of nerves for correctly reading the letters, but they also show one to re-read the letters that were missed in the first pass. Moreover, it is known that reversals can be performed as often as in every sentence and can start at any location in a sentence. Here, we report experimental results on the feasibility of an algorithm that can render a machine to automatically adapt to reversal gestures of one's finger. Through Braille-reading-analogous tasks, the algorithm is tested with thirty sighted subjects that volunteered in the study. We find that the finger motion adaptive algorithm (FMAA) is useful in achieving cooperation between human finger and the machine. In the presence of FMAA, subjects' performance metrics associated with the tasks have significantly improved as supported by statistical analysis. In light of these encouraging results, preliminary experiments are carried out with five blind subjects with the aim to put the algorithm to test. Results obtained from carefully designed experiments showed that subjects' Braille reading accuracy in the presence of FMAA was more favorable then when FMAA was turned off. Utilization of FMAA in future generation Braille reading devices thus holds strong promise.

  14. Stable expression of mtlD gene imparts multiple stress tolerance in finger millet.

    Science.gov (United States)

    Hema, Ramanna; Vemanna, Ramu S; Sreeramulu, Shivakumar; Reddy, Chandrasekhara P; Senthil-Kumar, Muthappa; Udayakumar, Makarla

    2014-01-01

    Finger millet is susceptible to abiotic stresses, especially drought and salinity stress, in the field during seed germination and early stages of seedling development. Therefore developing stress tolerant finger millet plants combating drought, salinity and associated oxidative stress in these two growth stages is important. Cellular protection through osmotic adjustment and efficient free radical scavenging ability during abiotic stress are important components of stress tolerance mechanisms in plants. Mannitol, an osmolyte, is known to scavenge hydroxyl radicals generated during various abiotic stresses and thereby minimize stress damage in several plant species. In this study transgenic finger millet plants expressing the mannitol biosynthetic pathway gene from bacteria, mannitol-1-phosphate dehydrogenase (mtlD), were developed through Agrobacterium tumefaciens-mediated genetic transformation. mtlD gene integration in the putative transgenic plants was confirmed by Southern blot. Further, performance of transgenic finger millet under drought, salinity and oxidative stress was studied at plant level in T1 generation and in T1 and T2 generation seedlings. Results from these experiments showed that transgenic finger millet had better growth under drought and salinity stress compared to wild-type. At plant level, transgenic plants showed better osmotic adjustment and chlorophyll retention under drought stress compared to the wild-type. However, the overall increase in stress tolerance of transgenics for the three stresses, especially for oxidative stress, was only marginal compared to other mtlD gene expressing plant species reported in the literature. Moreover, the Agrobacterium-mediated genetic transformation protocol developed for finger millet in this study can be used to introduce diverse traits of agronomic importance in finger millet.

  15. Finger tapping analysis in patients with Parkinson's disease and atypical parkinsonism.

    Science.gov (United States)

    Djurić-Jovičić, Milica; Petrović, Igor; Ječmenica-Lukić, Milica; Radovanović, Saša; Dragašević-Mišković, Nataša; Belić, Minja; Miler-Jerković, Vera; Popović, Mirjana B; Kostić, Vladimir S

    2016-08-01

    The goal of this study was to investigate repetitive finger tapping patterns in patients with Parkinson's disease (PD), progressive supranuclear palsy-Richardson syndrome (PSP-R), or multiple system atrophy of parkinsonian type (MSA-P). The finger tapping performance was objectively assessed in PD (n=13), PSP-R (n=15), and MSA-P (n=14) patients and matched healthy controls (HC; n=14), using miniature inertial sensors positioned on the thumb and index finger, providing spatio-temporal kinematic parameters. The main finding was the lack or only minimal progressive reduction in amplitude during the finger tapping in PSP-R patients, similar to HC, but significantly different from the sequence effect (progressive decrement) in both PD and MSA-P patients. The mean negative amplitude slope of -0.12°/cycle revealed less progression of amplitude decrement even in comparison to HC (-0.21°/cycle, p=0.032), and particularly from PD (-0.56°/cycle, p=0.001), and MSA-P patients (-1.48°/cycle, p=0.003). No significant differences were found in the average finger separation amplitudes between PD, PSP-R and MSA-P patients (pmsa-pd=0.726, pmsa-psp=0.363, ppsp-pd=0.726). The lack of clinically significant sequence effect during finger tapping differentiated PSP-R from both PD and MSA-P patients, and might be specific for PSP-R. The finger tapping kinematic parameter of amplitude slope may be a neurophysiological marker able to differentiate particular forms of parkinsonism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Stable expression of mtlD gene imparts multiple stress tolerance in finger millet.

    Directory of Open Access Journals (Sweden)

    Ramanna Hema

    Full Text Available Finger millet is susceptible to abiotic stresses, especially drought and salinity stress, in the field during seed germination and early stages of seedling development. Therefore developing stress tolerant finger millet plants combating drought, salinity and associated oxidative stress in these two growth stages is important. Cellular protection through osmotic adjustment and efficient free radical scavenging ability during abiotic stress are important components of stress tolerance mechanisms in plants. Mannitol, an osmolyte, is known to scavenge hydroxyl radicals generated during various abiotic stresses and thereby minimize stress damage in several plant species. In this study transgenic finger millet plants expressing the mannitol biosynthetic pathway gene from bacteria, mannitol-1-phosphate dehydrogenase (mtlD, were developed through Agrobacterium tumefaciens-mediated genetic transformation. mtlD gene integration in the putative transgenic plants was confirmed by Southern blot. Further, performance of transgenic finger millet under drought, salinity and oxidative stress was studied at plant level in T1 generation and in T1 and T2 generation seedlings. Results from these experiments showed that transgenic finger millet had better growth under drought and salinity stress compared to wild-type. At plant level, transgenic plants showed better osmotic adjustment and chlorophyll retention under drought stress compared to the wild-type. However, the overall increase in stress tolerance of transgenics for the three stresses, especially for oxidative stress, was only marginal compared to other mtlD gene expressing plant species reported in the literature. Moreover, the Agrobacterium-mediated genetic transformation protocol developed for finger millet in this study can be used to introduce diverse traits of agronomic importance in finger millet.

  17. Spoof Detection for Finger-Vein Recognition System Using NIR Camera

    Directory of Open Access Journals (Sweden)

    Dat Tien Nguyen

    2017-10-01

    Full Text Available Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD, is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor based on the observations of the researchers about the difference between real (live and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR camera-based finger-vein recognition system using convolutional neural network (CNN to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA for dimensionality reduction of feature space and support vector machine (SVM for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared

  18. Spoof Detection for Finger-Vein Recognition System Using NIR Camera.

    Science.gov (United States)

    Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung

    2017-10-01

    Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN

  19. Haematopoietic malignancies caused by dysregulation of a chromatin-binding PHD finger.

    Science.gov (United States)

    Wang, Gang G; Song, Jikui; Wang, Zhanxin; Dormann, Holger L; Casadio, Fabio; Li, Haitao; Luo, Jun-Li; Patel, Dinshaw J; Allis, C David

    2009-06-11

    Histone H3 lysine 4 methylation (H3K4me) has been proposed as a critical component in regulating gene expression, epigenetic states, and cellular identities1. The biological meaning of H3K4me is interpreted by conserved modules including plant homeodomain (PHD) fingers that recognize varied H3K4me states. The dysregulation of PHD fingers has been implicated in several human diseases, including cancers and immune or neurological disorders. Here we report that fusing an H3K4-trimethylation (H3K4me3)-binding PHD finger, such as the carboxy-terminal PHD finger of PHF23 or JARID1A (also known as KDM5A or RBBP2), to a common fusion partner nucleoporin-98 (NUP98) as identified in human leukaemias, generated potent oncoproteins that arrested haematopoietic differentiation and induced acute myeloid leukaemia in murine models. In these processes, a PHD finger that specifically recognizes H3K4me3/2 marks was essential for leukaemogenesis. Mutations in PHD fingers that abrogated H3K4me3 binding also abolished leukaemic transformation. NUP98-PHD fusion prevented the differentiation-associated removal of H3K4me3 at many loci encoding lineage-specific transcription factors (Hox(s), Gata3, Meis1, Eya1 and Pbx1), and enforced their active gene transcription in murine haematopoietic stem/progenitor cells. Mechanistically, NUP98-PHD fusions act as 'chromatin boundary factors', dominating over polycomb-mediated gene silencing to 'lock' developmentally critical loci into an active chromatin state (H3K4me3 with induced histone acetylation), a state that defined leukaemia stem cells. Collectively, our studies represent, to our knowledge, the first report that deregulation of the PHD finger, an 'effector' of specific histone modification, perturbs the epigenetic dynamics on developmentally critical loci, catastrophizes cellular fate decision-making, and even causes oncogenesis during mammalian development.

  20. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    Science.gov (United States)

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  1. An Optimal Design of Driving Mechanism in a 1 Degree of Freedom (d.o.f. Anthropomorphic Finger

    Directory of Open Access Journals (Sweden)

    M. Ceccarelli

    2005-01-01

    Full Text Available Mechanisms can be used in finger design to obtain suitable actuation systems and to give stiff robust behavior in grasping tasks. The design of driving mechanisms for fingers has been attached at LARM in Cassino with the aim to obtain one degree of freedom actuation for an anthropomorphic finger. The dimensional design of a finger-driving mechanism has been formulated as a multi-objective optimization problem by using evaluation criteria for fundamental characteristics regarding with finger motion, grasping equilibrium and force transmission. The feasibility of the herein proposed optimum design procedure for a finger-driving mechanism has been tested by numerical examples that have been also used to enhance a prototype previously built at LARM in Cassino.

  2. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  3. A Novel Multi-Finger Gate Structure of AlGaN/GaN High Electron Mobility Transistor

    International Nuclear Information System (INIS)

    Cui Lei; Wang Quan; Wang Xiao-Liang; Xiao Hong-Ling; Wang Cui-Mei; Jiang Li-Juan; Feng Chun; Yin Hai-Bo; Gong Jia-Min; Li Bai-Quan; Wang Zhan-Guo

    2015-01-01

    A novel multi-finger gate high electron mobility transistor (HEMT) is designed to reduce the peak electric field value at the drain-side gate edge when the device is at off-state. The effective gate length (L_e_f_f) of the multi-finger gate device is smaller than that of the field plate gate device. In this work, field plate gate, five-finger gate and ten-finger gate devices are simulated. The results of the simulation indicate that the multi-finger gate device has a lower peak value than the device with the gate field plate. Moreover, this value would be further reduced when the number of gate fingers is increased. In addition, it has the potential to make the HEMT work in a higher frequency since it has a lower effective length of gate. (paper)

  4. Zinc-finger antiviral protein inhibits XMRV infection.

    Directory of Open Access Journals (Sweden)

    Xinlu Wang

    Full Text Available BACKGROUND: The zinc-finger antiviral protein (ZAP is a host factor that specifically inhibits the replication of certain viruses, including Moloney murine leukemia virus (MoMLV, HIV-1, and certain alphaviruses and filoviruses. ZAP binds to specific viral mRNAs and recruits cellular mRNA degradation machinery to degrade the target RNA. The common features of ZAP-responsive RNA sequences remain elusive and thus whether a virus is susceptible to ZAP can only be determined experimentally. Xenotropic murine leukemia virus-related virus (XMRV is a recently identified γ-retrovirus that was originally thought to be involved in prostate cancer and chronic fatigue syndrome but recently proved to be a laboratory artefact. Nonetheless, XMRV as a new retrovirus has been extensively studied. Since XMRV and MoMLV share only 67.9% sequence identity in the 3'UTRs, which is the target sequence of ZAP in MoMLV, whether XMRV is susceptible to ZAP remains to be determined. FINDINGS: We constructed an XMRV-luc vector, in which the coding sequences of Gag-Pol and part of Env were replaced with luciferase-coding sequence. Overexpression of ZAP potently inhibited the expression of XMRV-luc in a ZAP expression-level-dependent manner, while downregulation of endogenous ZAP rendered cells more sensitive to infection. Furthermore, ZAP inhibited the spreading of replication-competent XMRV. Consistent with the previously reported mechanisms by which ZAP inhibits viral infection, ZAP significantly inhibited the accumulation of XMRV-luc mRNA in the cytoplasm. The ZAP-responsive element in XMRV mRNA was mapped to the 3'UTR. CONCLUSIONS: ZAP inhibits XMRV replication by preventing the accumulation of viral mRNA in the cytoplasm. Documentation of ZAP inhibiting XMRV helps to broaden the spectrum of ZAP's antiviral activity. Comparison of the target sequences of ZAP in XMRV and MoMLV helps to better understand the features of ZAP-responsive elements.

  5. A three-fingered, touch-sensitive, metrological micro-robotic assembly tool

    International Nuclear Information System (INIS)

    Torralba, Marta; Hastings, D J; Thousand, Jeffery D; Nowakowski, Bartosz K; Smith, Stuart T

    2015-01-01

    This article describes a metrological, robotic hand to manipulate and measure micrometer size objects. The presented work demonstrates not only assembly operations, but also positioning control and metrology capability. Sample motion is achieved by a commercial positioning stage, which provides XYZ-displacements for assembly of components. A designed and manufactured gripper tool that incorporates 21 degrees-of-freedom for independent alignment of actuators, sensors, and the three fingers of this hand is presented. These fingers can be opened and closed by piezoelectric actuators through levered flexures providing an 80 μm displacement range measured with calibrated opto-interrupter based, knife-edge sensors. The operational ends of the fingers comprise of a quartz tuning fork with a 7 μm diameter 3.2 mm long carbon fiber extending from the end of one tuning fork tine. Finger-tip force-sensing is achieved by the monitoring of individual finger resonances typically at around 32 kHz. Experimental results included are focused on probe performance analysis. Pick and place operation using the three fingers is demonstrated with all fingers being continuously oscillated, a capability not possible with the previous single or two finger tweezer type designs. By monitoring electrical feedback during pick and place operations, changes in the response of the three probes demonstrate the ability to identify both grab and release operations. Component metrology has been assessed by contacting different micro-spheres of diameters 50(±7.5) μm, 135(±20) μm, and 140(±20) μm. These were measured by the micro robot to have diameters of 67, 133, and 126 μm respectively with corresponding deviations of 4.2, 4.9, and 4.3 μm. This deviation in the measured results was primarily due to the manual, joystick-based, contacting of the fingers, difficulties associated with centering the components to the axis of the hand, and lower contact sensitivity for the smallest sphere

  6. Involuntary Neuromuscular Coupling between the Thumb and Finger of Stroke Survivors during Dynamic Movement

    Directory of Open Access Journals (Sweden)

    Christopher L. Jones

    2018-03-01

    Full Text Available Finger–thumb coordination is crucial to manual dexterity but remains incompletely understood, particularly following neurological injury such as stroke. While being controlled independently, the index finger and thumb especially must work in concert to perform a variety of tasks requiring lateral or palmar pinch. The impact of stroke on this functionally critical sensorimotor control during dynamic tasks has been largely unexplored. In this study, we explored finger–thumb coupling during close–open pinching motions in stroke survivors with chronic hemiparesis. Two types of perturbations were applied randomly to the index with a novel Cable-Actuated Finger Exoskeleton: a sudden joint acceleration stretching muscle groups of the index finger and a sudden increase in impedance in selected index finger joint(s. Electromyographic signals for specific thumb and index finger muscles, thumb tip trajectory, and index finger joint angles were recorded during each trial. Joint angle perturbations invoked reflex responses in the flexor digitorum superficialis (FDS, first dorsal interossei (FDI, and extensor digitorum communis muscles of the index finger and heteronymous reflex responses in flexor pollicis brevis of the thumb (p < 0.017. Phase of movement played a role as a faster peak reflex response was observed in FDI during opening than during closing (p < 0.002 and direction of perturbations resulted in shorter reflex times for FDS and FDI (p < 0.012 for extension perturbations. Surprisingly, when index finger joint impedance was suddenly increased, thumb tip movement was substantially increased, from 2 to 10 cm (p < 0.001. A greater effect was seen during the opening phase (p < 0.044. Thus, involuntary finger–thumb coupling was present during dynamic movement, with perturbation of the index finger impacting thumb activity. The degree of coupling modulated with the phase of motion. These findings reveal a potential

  7. Radial viscous fingering of hot asthenosphere within the Icelandic plume beneath the North Atlantic Ocean

    Science.gov (United States)

    Schoonman, C. M.; White, N. J.; Pritchard, D.

    2017-06-01

    The Icelandic mantle plume has had a significant influence on the geologic and oceanographic evolution of the North Atlantic Ocean during Cenozoic times. Full-waveform tomographic imaging of this region shows that the planform of this plume has a complex irregular shape with significant shear wave velocity anomalies lying beneath the lithospheric plates at a depth of 100-200 km. The distribution of these anomalies suggests that about five horizontal fingers extend radially beneath the fringing continental margins. The best-imaged fingers lie beneath the British Isles and beneath western Norway where significant departures from crustal isostatic equilibrium have been measured. Here, we propose that these radial fingers are generated by a phenomenon known as the Saffman-Taylor instability. Experimental and theoretical analyses show that fingering occurs when a less viscous fluid is injected into a more viscous fluid. In radial, miscible fingering, the wavelength and number of fingers are controlled by the mobility ratio (i.e. the ratio of viscosities), by the Péclet number (i.e. the ratio of advective and diffusive transport rates), and by the thickness of the horizontal layer into which fluid is injected. We combine shear wave velocity estimates with residual depth measurements around the Atlantic margins to estimate the planform distribution of temperature and viscosity within a horizontal asthenospheric layer beneath the lithospheric plate. Our estimates suggest that the mobility ratio is at least 20-50, that the Péclet number is O (104), and that the asthenospheric channel is 100 ± 20 km thick. The existence and planform of fingering is consistent with experimental observations and with theoretical arguments. A useful rule of thumb is that the wavelength of fingering is 5 ± 1 times the thickness of the horizontal layer. Our proposal has been further tested by examining plumes of different vigor and planform (e.g. Hawaii, Cape Verde, Yellowstone). Our results

  8. Finger island flaps for treatment of dermato-desmogenic flexion contractures of proximal interphalangeal joints

    Directory of Open Access Journals (Sweden)

    T. S. Antonova

    2016-12-01

    Full Text Available Soft tissue defect will form after operative treatment of the dermato-desmogenic flexion contractures of fingers interphalangeal joints of the 2–3 grades after excision of the scar. Using the island flaps (Littler at the central vascular pedicle is one of the classical methods of plastic closure of such defects. Goal. To study the effectiveness of the surgical treatment of dermato-desmogenic flexion contractures of proximal interphalangeal joints of the fingers by using finger island flaps at the central vascular or neuro-vascular pedicle. Materials and methods. 14 operations were carried out on 13 patients for removing dermato-desmogenic flexion contractures of proximal interphalangeal (PIP joints of triphalangeal fingers over a 2-year period (2013–2015. The group included patients with a flexion contracture of the 2–3 grades PIP joints of triphalangeal fingers. Operations were performed on average 5 months after the injury (from 1.5 up to 16 months. Finger island flap in all cases was taken from adjacent finger by using the blood supply of their common finger artery. In all cases the island flap on the central pedicel was used, in 9 cases digital nerve was included in the pedicle (Littler. Closure of donor wound was made with free-skin grafts. Permanent splinting of the hand with extension of the interphalangeal joints and moderate flexion of the metacarpophalangeal joints were performed during 7–8 days after surgery, then exercise therapy was prescribed. Results. The results were estimated 6 and 12 months after surgery. All the results were regarded as excellent. In 5 cases of using the flap on a vascular pedicle flap hypoesthesia was detected, that has not led to dysfunction of the hand. Contracture recurrence during follow-up was not observed. Conclusions. Using the surgery for treatment of dermato-desmogenic flexion contractures of proximal interphalangeal joints of the fingers with the island flaps at the central vascular or neuro

  9. Multifunctional Merkel cells: their roles in electromagnetic reception, finger-print formation, Reiki, epigenetic inheritance and hair form.

    Science.gov (United States)

    Irmak, M Kemal

    2010-08-01

    Merkel cells are located in glabrous and hairy skin and in some mucosa. They are characterized by dense-core secretory granules and cytoskeletal filaments. They are attached to neighboring keratinocytes by desmosomes and contain melanosomes similar to keratinocytes. They are excitable cells in close contact with sensory nerve endings but their function is still unclear. In this review, following roles are attributed for the first time to the Merkel cells: (1) melanosomes in Merkel cells may be involved in mammalian magnetoreception. In this model melanosome as a biological magnetite is connected by cytoskeletal filaments to mechanically gated ion channels embedded in the Merkel cell membrane. The movement of melanosome with the changing electromagnetic field may open ion channels directly producing a receptor potential that can be transmitted to brain via sensory neurons. (2) Merkel cells may be involved in finger-print formation: Merkel cells in glabrous skin are located at the base of the epidermal ridges the type of which defines the finger-print pattern. Finger-print formation starts at the 10th week of pregnancy after the arrival of Merkel cells. Keratinocyte proliferation and the buckling process observed in the basal layer of epidermis resulting in the epidermal ridges may be controlled and formed by Merkel cells. (3) Brain-Merkel cell connection is bi-directional and Merkel cells not only absorb but also radiate the electromagnetic frequencies. Hence, efferent aspects of the palmar and plantar Merkel nerve endings may form the basis of the biofield modalities such as Reiki, therapeutic touch and telekinesis. (4) Adaptive geographic variations such as skin color, craniofacial morphology and hair form result from interactions between environmental factors and epigenetic inheritance system. While environmental factors produce modifications in the body, they simultaneously induce epigenetic modifications in the oocytes and in this way adaptive changes could be

  10. Cortex Inspired Model for Inverse Kinematics Computation for a Humanoid Robotic Finger

    Science.gov (United States)

    Gentili, Rodolphe J.; Oh, Hyuk; Molina, Javier; Reggia, James A.; Contreras-Vidal, José L.

    2013-01-01

    In order to approach human hand performance levels, artificial anthropomorphic hands/fingers have increasingly incorporated human biomechanical features. However, the performance of finger reaching movements to visual targets involving the complex kinematics of multi-jointed, anthropomorphic actuators is a difficult problem. This is because the relationship between sensory and motor coordinates is highly nonlinear, and also often includes mechanical coupling of the two last joints. Recently, we developed a cortical model that learns the inverse kinematics of a simulated anthropomorphic finger. Here, we expand this previous work by assessing if this cortical model is able to learn the inverse kinematics for an actual anthropomorphic humanoid finger having its two last joints coupled and controlled by pneumatic muscles. The findings revealed that single 3D reaching movements, as well as more complex patterns of motion of the humanoid finger, were accurately and robustly performed by this cortical model while producing kinematics comparable to those of humans. This work contributes to the development of a bioinspired controller providing adaptive, robust and flexible control of dexterous robotic and prosthetic hands. PMID:23366569

  11. Cortical Decoding of Individual Finger and Wrist Kinematics for an Upper-Limb Neuroprosthesis

    Science.gov (United States)

    Aggarwal, Vikram; Tenore, Francesco; Acharya, Soumyadipta; Schieber, Marc H.; Thakor, Nitish V.

    2010-01-01

    Previous research has shown that neuronal activity can be used to continuously decode the kinematics of gross movements involving arm and hand trajectory. However, decoding the kinematics of fine motor movements, such as the manipulation of individual fingers, has not been demonstrated. In this study, single unit activities were recorded from task-related neurons in M1 of two trained rhesus monkey as they performed individuated movements of the fingers and wrist. The primates’ hand was placed in a manipulandum, and strain gauges at the tips of each finger were used to track the digit’s position. Both linear and non-linear filters were designed to simultaneously predict kinematics of each digit and the wrist, and their performance compared using mean squared error and correlation coefficients. All models had high decoding accuracy, but the feedforward ANN (R=0.76–0.86, MSE=0.04–0.05) and Kalman filter (R=0.68–0.86, MSE=0.04–0.07) performed better than a simple linear regression filter (0.58–0.81, 0.05–0.07). These results suggest that individual finger and wrist kinematics can be decoded with high accuracy, and be used to control a multi-fingered prosthetic hand in real-time. PMID:19964645

  12. An endophytic fungus isolated from finger millet (Eleucine coracona produces anti-fungal natural products

    Directory of Open Access Journals (Sweden)

    Walaa Kamel Mousa

    2015-10-01

    Full Text Available Finger millet is an ancient African cereal crop, domesticated 7000 years ago in Ethiopia, reaching India at 3000 BC. Finger millet is reported to be resistant to various fungal pathogens including Fusarium sp. We hypothesized that finger millet may host beneficial endophytes (plant-colonizing microbes that contribute to the antifungal activity. Here we report the first isolation of endophyte(s from finger millet. Five distinct fungal species were isolated from roots and predicted taxonomically based on 18S rDNA sequencing. Extracts from three putative endophytes inhibited growth of F. graminearum and three other pathogenic Fusarium species. The most potent anti-Fusarium strain (WF4, predicted to be a Phoma sp. was confirmed to behave as an endophyte using pathogenicity and confocal microscopy experiments. Bioassay-guided fractionation of the WF4 extract identified four anti-fungal compounds, viridicatol, tenuazonic acid, alternariol and alternariol monomethyl ether. All the purified compounds caused dramatic breakage of F. graminearum hyphae in vitro. These compounds have not previously been reported to have anti-Fusarium activity. None of the compounds, except for tenuazonic acid, have previously been reported to be produced by Phoma. We conclude that the ancient, disease-tolerant crop, finger millet, is a novel source of endophytic anti-fungal natural products. This paper suggests the value of the crops grown by subsistence farmers as sources of endophytes and their natural products. Application of these natural chemicals to solve real world problems will require further validation.

  13. Finger millet (Eleusine coracana) - an economically viable source for antihypercholesterolemic metabolites production by Monascus purpureus.

    Science.gov (United States)

    Venkateswaran, V; Vijayalakshmi, G

    2010-08-01

    Rice, parboiled rice, finger millet, germinated finger millet, broken wheat, njavara (medicinal rice), sorghum and maize were used as substrates for solid state fermentation of Monascus purpureus at 28°C for 7 days using 2% seed medium as inoculum for the production of its metabolites. The fungus exhibited good growth in all the substrates. The fermented substrates were dried at 45°C and analysed for antihypercholesterolemic metabolite statins by standardized HPLC method and dietary sterol contents by spectrophotometric method using reference standards of statin (pravastatin and lovastatin) and cholesterol, respectively. Germinated finger millet yielded higher total statin production of 5.2 g/kg dry wt with pravastatin and lovastatin content of 4.9 and 0.37 g/kg dry wt respectively than other substrates which range from 1.04-4.41 g/kg. In addition to statin, monascus fermented germinated finger millet yielded dietary sterol of 0.053 g/kg dry wt which is 7.6 folds higher than the control. The value addition of finger millet by germination and fermentation with Monascus purpureus provides scope for development of functional food.

  14. An endophytic fungus isolated from finger millet (Eleusine coracana) produces anti-fungal natural products.

    Science.gov (United States)

    Mousa, Walaa K; Schwan, Adrian; Davidson, Jeffrey; Strange, Philip; Liu, Huaizhi; Zhou, Ting; Auzanneau, France-Isabelle; Raizada, Manish N

    2015-01-01

    Finger millet is an ancient African cereal crop, domesticated 7000 years ago in Ethiopia, reaching India at 3000 BC. Finger millet is reported to be resistant to various fungal pathogens including Fusarium sp. We hypothesized that finger millet may host beneficial endophytes (plant-colonizing microbes) that contribute to the antifungal activity. Here we report the first isolation of endophyte(s) from finger millet. Five distinct fungal species were isolated from roots and predicted taxonomically based on 18S rDNA sequencing. Extracts from three putative endophytes inhibited growth of F. graminearum and three other pathogenic Fusarium species. The most potent anti-Fusarium strain (WF4, predicted to be a Phoma sp.) was confirmed to behave as an endophyte using pathogenicity and confocal microscopy experiments. Bioassay-guided fractionation of the WF4 extract identified four anti-fungal compounds, viridicatol, tenuazonic acid, alternariol, and alternariol monomethyl ether. All the purified compounds caused dramatic breakage of F. graminearum hyphae in vitro. These compounds have not previously been reported to have anti-Fusarium activity. None of the compounds, except for tenuazonic acid, have previously been reported to be produced by Phoma. We conclude that the ancient, disease-tolerant crop, finger millet, is a novel source of endophytic anti-fungal natural products. This paper suggests the value of the crops grown by subsistence farmers as sources of endophytes and their natural products. Application of these natural chemicals to solve real world problems will require further validation.

  15. Insights using the molecular model of Lipoxygenase from Finger millet (Eleusine coracana (L.)).

    Science.gov (United States)

    Tiwari, Apoorv; Avashthi, Himanshu; Jha, Richa; Srivastava, Ambuj; Kumar Garg, Vijay; Wasudev Ramteke, Pramod; Kumar, Anil

    2016-01-01

    Lipoxygenase-1 (LOX-1) protein provides defense against pests and pathogens and its presence have been positively correlated with plant resistance against pathogens. Linoleate is a known substrate of lipoxygenase and it induces necrosis leading to the accumulation of isoflavonoid phytoalexins in plant leaves. Therefore, it is of interest to study the structural features of LOX-1 from Finger millet. However, the structure ofLOX-1 from Finger millet is not yet known. A homology model of LOX-1 from Finger millet is described. Domain architecture study suggested the presence of two domains namely PLAT (Phospho Lipid Acyl Transferase) and lipoxygenase. Molecular docking models of linoleate with lipoxygenase from finger millet, rice and sorghum are reported. The features of docked models showed that finger millet have higher pathogen resistance in comparison to other cereal crops. This data is useful for the molecular cloning of fulllength LOX-1 gene for validating its role in improving plant defense against pathogen infection and for various other biological processes.

  16. Estimation method of finger tapping dynamics using simple magnetic detection system

    Science.gov (United States)

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  17. Amputation of finger by horse bite with complete avulsion of both flexor tendons.

    Science.gov (United States)

    Koren, Lior; Stahl, Shalom; Rovitsky, Alexey; Peled, Eli

    2011-08-08

    Amputation of fingers with tendon avulsion occurs through a traction injury, and most occur through a ring avulsion mechanism. Usually the flexor digitorum profundus is torn out with the amputated finger. Replantation usually is recommended only when the amputation is distal to the flexor digitorum superficialis insertion. Animal bites are relatively common, with a decreasing order of frequency of dogs, cats, and humans. Horse bites are relatively infrequent but are associated with crush injuries and tissue loss when they occur. This article describes a 23-year-old man with amputation of his middle finger at the level of the proximal phalanx after being bitten by a horse. The amputated stump was avulsed with the middle finger flexor digitorum profundus and flexor digitorum superficialis torn from the muscle-tendon junction from approximately the middle of the forearm. The patient had no other injuries, and he was able to move his other 4 fingers with only mild pain. As the amputated digit was not suitable for replantation, the wound was irrigated and debrided. The edges of the phalanx were trimmed, and the edges of the wound were sutured. Tetanus toxoid and rabies vaccine were administered, along with intravenous amoxicillin and clavulanic acid. The patient was discharged from the hospital 2 days later, with no sign of infection of the wound or compartment syndrome of the forearm. This case demonstrates the weakest point in the myotendinous junction and emphasizes the importance of a careful physical examination in patients with a traumatic amputation. Copyright 2011, SLACK Incorporated.

  18. Laterality of repetitive finger movement performance and clinical features of Parkinson's disease.

    Science.gov (United States)

    Stegemöller, Elizabeth; Zaman, Andrew; MacKinnon, Colum D; Tillman, Mark D; Hass, Chris J; Okun, Michael S

    2016-10-01

    Impairments in acoustically cued repetitive finger movement often emerge at rates near to and above 2Hz in persons with Parkinson's Disease (PD) in which some patients move faster (hastening) and others move slower (bradykinetic). The clinical features impacting this differential performance of repetitive finger movement remain unknown. The purpose of this study was to compare repetitive finger movement performance between the more and less affected side, and the difference in clinical ratings among performance groups. Forty-one participants diagnosed with idiopathic PD completed an acoustically cued repetitive finger movement task while "on" medication. Eighteen participants moved faster, 10 moved slower, and 13 were able to maintain the appropriate rate at rates above 2Hz. Clinical measures of laterality, disease severity, and the UPDRS were obtained. There were no significant differences between the more and less affected sides regardless of performance group. Comparison of disease severity, tremor, and rigidity among performance groups revealed no significant differences. Comparison of posture and postural instability scores revealed that the participants that demonstrated hastening had worse posture and postural instability scores. Consideration of movement rate during the clinical evaluation of repetitive finger movement may provide additional insight into varying disease features in persons with PD. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Estimation method of finger tapping dynamics using simple magnetic detection system.

    Science.gov (United States)

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  20. Non-invasive determination of the irradiation dose in fingers using low-frequency EPR

    International Nuclear Information System (INIS)

    Zdravkova, M; Crokart, N; Trompier, F; Beghein, N; Gallez, B; Debuyst, R

    2004-01-01

    Several reports in the literature have described the effects of radiation in workers who exposed their fingers to intense radioactive sources. The radiation injuries occurring after local exposure to a high dose (20 to 100 Gy) could lead to the need for amputation. Follow-up of victims needs to be more rational with a precise knowledge of the irradiated area that risks tissue degradation and necrosis. It has been described previously that X-band electron paramagnetic resonance (EPR) spectroscopy could be used to assess the dose in irradiated amputated fingers. Here, we propose the use of low-frequency EPR spectroscopy to evaluate non-invasively the absorbed dose. Low-frequency microwaves are indeed less absorbed by water and penetrate more deeply into living material (∼10 mm in tissues using 1 GHz spectrometers). This work presents preliminary results obtained with baboon and human fingers compared with human dry phalanxes placed inside a surface-coil resonator. The EPR signal increased linearly with the dose. The ratio of the slopes of the dry bone to whole finger linear regression lines was around 5. The detection limit achievable with the present spectrometer and resonator is around 60 Gy, which is well within the range of accidentally exposed fingers. It is likely that the detection limit could be improved in the future, thanks to further technical spectrometer and resonator developments as well as to appropriate spectrum deconvolution into native and dosimetric signals