WorldWideScience

Sample records for integration test rfp

  1. Tokamak and RFP ignition requirements

    International Nuclear Information System (INIS)

    Werley, K.A.

    1991-01-01

    A plasma model is applied to calculate numerically transport- confinement (nτ E ) requirements and steady-state operation tokamak. The CIT tokamak and RFP ignition conditions are examined. Physics differences between RFP and tokamaks, and their consequences for a DT ignition machine, are discussed. The ignition RFP, compared to a tokamak, has many physics advantages, including ohmic heating to ignition (no need for auxiliary heating systems), higher beta, low ignition current, less sensitivity of ignition requirements to impurity effects, no hard disruptions (associated with beta or density limits), and successful operation with high radiation fractions (f RAD ∼ 0.95). These physics advantages, coupled with important engineering advantages associated with lower external magnetic fields, larger aspect ratios, and smaller plasma cross sections translate into significant cost reductions for both ignition and power reactor. The primary drawback of the RFP is the uncertainty that the present confinement scaling will extrapolate to reactor regimes. The 4-MA ZTH was expected to extend the nτ E transport scaling data three order of magnitude above ZT-40M results, and if the present scaling held, to achieve a DT-equivalent scientific energy breakeven, Q=1. A basecase RFP ignition point is identified with a plasma current of 8.1 MA and no auxiliary heating. 16 refs., 4 figs., 1 tab

  2. Enhancing the biophysical properties of mRFP1 through incorporation of fluoroproline

    Energy Technology Data Exchange (ETDEWEB)

    Deepankumar, Kanagavel; Nadarajan, Saravanan Prabhu; Ayyadurai, Niraikulam; Yun, Hyungdon, E-mail: hyungdon@ynu.ac.kr

    2013-11-01

    Graphical abstract: Enhancing the biophysical properties of mRFP1 through incorporation of (2S, 4R)-4-fluoroproline at proline residues after mutating non-permissive site Pro63 into Ala. -- Highlights: •We incorporate (4S)-FP into mRFP1 led to insoluble protein. •Whereas, incorporation of (4R)-FP resulted in soluble but lost its fluorescence. •mRFP1-P63A mutant accommodate (4R)-FP and gave soluble protein with fluorescence. •Moreover mRFP1-P63A[(4R)-FP] showed enhanced biophysical properties of protein. -- Abstract: Here we enhanced the stability and biophysical properties of mRFP1 through a combination of canonical and non-canonical amino acid mutagenesis. The global replacement of proline residue with (2S, 4R)-4-fluoroproline [(4R)-FP] into mRFP1 led to soluble protein but lost its fluorescence, whereas (2S, 4S)-4-fluoroproline [(4S)-FP] incorporation resulted in insoluble protein. The bioinformatics analysis revealed that (4R)-FP incorporation at Pro63 caused fluorescence loss due to the steric hindrance of fluorine atom of (4R)-FP with the chromophore. Therefore, Pro63 residue was mutated with the smallest amino acid Ala to maintain non coplanar conformation of the chromophore and helps to retain its fluorescence with (4R)-FP incorporation. The incorporation of (4R)-FP into mRFP1-P63A showed about 2–3-fold enhancement in thermal and chemical stability. The rate of maturation is also greatly accelerated over the presence of (4R)-FP into mRFP1-P63A. Our study showed that a successful enhancement in the biophysical property of mRFP1-P63A[(4R)-FP] using non-canonical amino acid mutagenesis after mutating non-permissive site Pro63 into Ala.

  3. Enhancing the biophysical properties of mRFP1 through incorporation of fluoroproline

    International Nuclear Information System (INIS)

    Deepankumar, Kanagavel; Nadarajan, Saravanan Prabhu; Ayyadurai, Niraikulam; Yun, Hyungdon

    2013-01-01

    Graphical abstract: Enhancing the biophysical properties of mRFP1 through incorporation of (2S, 4R)-4-fluoroproline at proline residues after mutating non-permissive site Pro63 into Ala. -- Highlights: •We incorporate (4S)-FP into mRFP1 led to insoluble protein. •Whereas, incorporation of (4R)-FP resulted in soluble but lost its fluorescence. •mRFP1-P63A mutant accommodate (4R)-FP and gave soluble protein with fluorescence. •Moreover mRFP1-P63A[(4R)-FP] showed enhanced biophysical properties of protein. -- Abstract: Here we enhanced the stability and biophysical properties of mRFP1 through a combination of canonical and non-canonical amino acid mutagenesis. The global replacement of proline residue with (2S, 4R)-4-fluoroproline [(4R)-FP] into mRFP1 led to soluble protein but lost its fluorescence, whereas (2S, 4S)-4-fluoroproline [(4S)-FP] incorporation resulted in insoluble protein. The bioinformatics analysis revealed that (4R)-FP incorporation at Pro63 caused fluorescence loss due to the steric hindrance of fluorine atom of (4R)-FP with the chromophore. Therefore, Pro63 residue was mutated with the smallest amino acid Ala to maintain non coplanar conformation of the chromophore and helps to retain its fluorescence with (4R)-FP incorporation. The incorporation of (4R)-FP into mRFP1-P63A showed about 2–3-fold enhancement in thermal and chemical stability. The rate of maturation is also greatly accelerated over the presence of (4R)-FP into mRFP1-P63A. Our study showed that a successful enhancement in the biophysical property of mRFP1-P63A[(4R)-FP] using non-canonical amino acid mutagenesis after mutating non-permissive site Pro63 into Ala

  4. RFP plasma experiment at INPE

    International Nuclear Information System (INIS)

    Ueda, M.; Aso, Y.

    1988-01-01

    Plasma experiments in CECI, a small Reversed Field Pinch (RFP) apparatus, are described. Preliminary measurements in this device shown the production of a plasma with peak current of 1.3kA and discharge duration of nearly 80μs, when a toroidal DC field of 100G was used. A loop voltage of 40V was measured and a maximum electron temperature of 3eV was estimated for these discharges. Experimental points in the F-θ diagram for CECI indicate that its plasma is approaching the RFP configuration when the discharge is optimize. The probe data also show that the plasma column expands outward. Numerical results indicate that leakage fields have to be reduced below 5G to form appropriate magnetic surfaces. (author) [pt

  5. Design principles for a large RFP experiment

    International Nuclear Information System (INIS)

    Phillpott, J.; Rostagni, G.; Di Marco, J.

    1981-01-01

    An RFP experiment (RFX) has been designed by an International Design Team, by groups of collaborating physicists and engineers working in their home laboratories. This international collaborative project has been brought to an advanced stage of system and component design by the co-operation of three design teams under the co-ordination of a Design Manager, based at Culham Laboratory. The paper summaries the important design principles for an RFP device, based on the outcome of this collaborative design project

  6. Efektivitas penggunaan gambir sebagai bahan penyamak nabati sistem C-RFP untuk pembuatan kulit jaket dari kulit domba

    Directory of Open Access Journals (Sweden)

    Sri Sutyasmi

    2017-06-01

    Full Text Available Gambier is obtained from the extraction of leaves and young twigs of Uncaria gambir, a shrub that grows in Indonesia. Gambier contains tannin by 20% to 55% so that can be used as a vegetable tanning material using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum, P=Powder. This research aimed to determine the effectiveness of gambier as a vegetable tanning material using the C-RFP system. Pickled leather underwent a tanning process using the C-RFP system with gambier as the tanning material at various percentages, namely by 15%, 20%, and 25%, to be processed as leather for jackets. The variations of oil used to keep the leather supple were 12.5%, 15%, and 17.5%. The tanned leather was then tested in terms of its organoleptic, physical, chemical, and morphological properties. Results of the organoleptic test and most of the results of the physical test showed that leather for jackets which was tanned using a vegetable tanning material met the requirements set out by SNI 4593: 2011 (sheepskin/goatskin leather for jackets. Results of the SEM test indicated that leather for jackets which was tanned using a vegetable tanning material displayed dense and strong skin tissue, and this proves that gambier is very effective for vegetable tanning using the C-RFP system.

  7. Large non-circular RFP experiments at Wisconsin

    International Nuclear Information System (INIS)

    Sprott, J.C.; Dexter, R.N.; Prager, S.C.; Almagri, A.F.; Assadi, S.; Sarff, J.S.

    1986-01-01

    By removing the internal rings from the Levitated Octupole vacuum vessel, a large, non-circular RFP was produced. The major radius is 1.39 m, and the cross section is about 1 m/sup 2/. The device is unconventional in that the vacuum vessel, which consists of 5-cm thick aluminum with a single poloidal and toroidal gap, serves as the vacuum liner, conducting shell, and poloidal and toroidal field coils. A toroidal field of up to about 1 kG can be produced, and the poloidal field is driven by a 600 kJ capacitor bank through a 2-volt-second iron core. Discharges are initiated with 4200 volts per turn using self-reversal of the toroidal field in order to prevent arcing of the poloidal gap which is exposed to the plasma. The gap is protected with a 20-cm wide strip of ceramic. The best RFP discharges have a peak current of ≅200 kA and a duration of ≅ 10 msec. The toroidal field reverses when the current reaches ≅100 kA, making this one of the lowest current density RFP's in existence. The current ramps up to the final value over ≅10 resistive diffusion times and terminates only because the volt-second limit of the iron core is reached. The F-θ trajectory lies slightly to the right of the λ=constant theory as do all other RFP devices. Discharges have been produced with θ up to 2.5 and F as low as -0.8. A feature of the device is that it is capable of producing discharges with plasma current of ≅100 kA and ≅10 msec duration over a wide range of safety factor from the q>1 tokamak limit to the deeply-reversed, RFP limit. The highest current discharges (≅300 kA) are obtained at q≅0.5

  8. Optimization of RFP formation and sustainment in RFX

    Energy Technology Data Exchange (ETDEWEB)

    Martini, S.; Buffa, A.; Collarin, P.; Lorenzi, A. De; Fiorentin, P.; Innocente, P.; Marchiori, G.; Paccagnella, R.; Piovan, R.; Sonato, P. [Istituto Gas Ionizzati del CNR, EURATOM-ENEA-CNR Association, Padua (Italy)

    1993-12-31

    In the first months of 1993, the RFX experiment (R=2 m, a=0.46 m) has operated at reduced volt-second (6 V{center_dot}s out of 15) to study the formation and sustainment of the RFP in a relatively safer power input regime, before increasing the parameters to reach the design value of 2 MA plasma current. At present the RFP configuration is obtained, similarly to the ETA-BETA II experiment, in the aided mode: a capacitor bank is discharged into the toroidal winding to produce an initial toroidal flux, {Phi}{sub T}, then the plasma current, I{sub T}, is induced by varying the poloidal flux stored in the magnetising winding; the free oscillation of the toroidal circuit continues and {Phi}{sub T} decays during the initial plasma current rise, until the toroidal field at the wall, B{sub T}(a), reverses and the toroidal circuit is crow-barred. The overall performance of the plasma during the RFP sustainment phase is strongly influenced by the control performed on density, toroidal field and plasma position during the formation phase. As soon as the RFP is obtained, a clear improvement of confinement is seen and the plasma current increases again until the applied toroidal voltage V{sub T}, which decreases exponentially, no longer matches the resistive drop. In RFX it is also possible to insert a pre-programmed flat-top power amplifier by which V{sub T} can be sustained and controlled in the range (0-60 V). In this way quasi-steady RFP current flat-top phases lasting {approx} 90 ms can be obtained which terminate only when the amplifiers are switched off and V{sub T} is no longer sustained. (author) 9 refs., 6 figs.

  9. Optimization of RFP formation and sustainment in RFX

    International Nuclear Information System (INIS)

    Martini, S.; Buffa, A.; Collarin, P.; Lorenzi, A. De; Fiorentin, P.; Innocente, P.; Marchiori, G.; Paccagnella, R.; Piovan, R.; Sonato, P.

    1993-01-01

    In the first months of 1993, the RFX experiment (R=2 m, a=0.46 m) has operated at reduced volt-second (6 V·s out of 15) to study the formation and sustainment of the RFP in a relatively safer power input regime, before increasing the parameters to reach the design value of 2 MA plasma current. At present the RFP configuration is obtained, similarly to the ETA-BETA II experiment, in the aided mode: a capacitor bank is discharged into the toroidal winding to produce an initial toroidal flux, Φ T , then the plasma current, I T , is induced by varying the poloidal flux stored in the magnetising winding; the free oscillation of the toroidal circuit continues and Φ T decays during the initial plasma current rise, until the toroidal field at the wall, B T (a), reverses and the toroidal circuit is crow-barred. The overall performance of the plasma during the RFP sustainment phase is strongly influenced by the control performed on density, toroidal field and plasma position during the formation phase. As soon as the RFP is obtained, a clear improvement of confinement is seen and the plasma current increases again until the applied toroidal voltage V T , which decreases exponentially, no longer matches the resistive drop. In RFX it is also possible to insert a pre-programmed flat-top power amplifier by which V T can be sustained and controlled in the range (0-60 V). In this way quasi-steady RFP current flat-top phases lasting ∼ 90 ms can be obtained which terminate only when the amplifiers are switched off and V T is no longer sustained. (author) 9 refs., 6 figs

  10. Engineering design of a compact RFP reactor (CRFPR)

    International Nuclear Information System (INIS)

    Hagenson, R.L.; Krakowski, R.A.

    1983-01-01

    The results of a previously-reported comprehensive parametric systems analysis of the Reversed-Field Pinch (RFP) give strong indications for minimum-cost systems that would operate with resistive water-cooled copper coils and higher first-wall neutron current (15 to 20 MW/m 2 ). These minimum-cost, compact RFP reactors (CRFPRs) have system power densities that can be comparable with fission power plants and, therefore, are 10 to 30 times smaller than most superconducting approaches. Reported herein are initial results of a conceptual engineering design of key fusion-power-core (FPC) subsystems

  11. Over-relaxation phenomena during the set-up of RFP plasmas

    International Nuclear Information System (INIS)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab

  12. Over-relaxation phenomena during the set-up of RFP plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab.

  13. The reduction of low frequency fluctuations in RFP experiments

    International Nuclear Information System (INIS)

    Phillips, J.A.; Baker, D.A.; Gribble, R.F.

    1998-01-01

    The low frequency fluctuations seen in RFP experiments are found to be correlated with changes in the toroidal flux measured by diamagnetic loops surrounding the discharge. The correlation of the onset of impurity radiation and x-rays with the crash seen in experiments is caused by plasma bombarding the metal liner associated with this loss of flux. Efforts should be made to design improved stabilizing shells that will reduce the loss of flux and give improved RFP energy confinement times

  14. The first results of siliconization on SWIP-RFP device

    International Nuclear Information System (INIS)

    Zhang Peng; Li Qiang; Luo Cuiwen; Li Jieping; Qian Shangjie; Fang Shuiquan; Yi Ping; Xue Jun; Li Kehua; Luo Junlin; Hong Wenyu; Cao Zeng; Zhang Nianman; Wang Quanming; Li Jie; Huang Ming; Zhong Yunze; Zhang Qingchun; Luo Cuixian

    1997-01-01

    The first results of reversed field pinch (RFP) and ultra low safety factor (ULQ) plasma experiments with siliconization on SWIP-RFP device are presented in this paper. The siliconization decreases the impurity concentrations in the plasma and increases the configuration sustainment time. Ion temperature has been estimated with the CV line of the visible light spectra and the broadening of CIII lines in vacuum ultraviolet (VUV) region. The anomalous ion heating as well as the anomalous resistance were observed. (orig.)

  15. Allelism analysis of BrRfp locus in different restorer lines and map-based cloning of a fertility restorer gene, BrRfp1, for pol CMS in Chinese cabbage (Brassica rapa L.).

    Science.gov (United States)

    Zhang, Huamin; Wu, Junqing; Dai, Zihui; Qin, Meiling; Hao, Lingyu; Ren, Yanjing; Li, Qingfei; Zhang, Lugang

    2017-03-01

    In Chinese cabbage, there are two Rf loci for pol CMS and one of them was mapped to a 12.6-kb region containing a potential candidate gene encoding PPR protein. In Chinese cabbage (Brassica rapa), polima cytoplasmic male sterility (pol CMS) is an important CMS type and is widely used for hybrid breeding. By extensive test crossing in Chinese cabbage, four restorer lines (92s105, 01s325, 00s109, and 88s148) for pol CMS were screened. By analyzing the allelism of the four restorer lines, it was found that 92s105, 01s325, and 00s109 had the same "restorers of fertility" (Rf) locus (designated as BrRfp1), but 88s148 had a different Rf locus (designated as BrRfp2). For fine mapping the BrRfp1 locus of 92s105, a BC 1 F 1 population with 487 individuals and a BC 1 F 2 population with 2485 individuals were successively constructed. Using simple sequence repeat (SSR) markers developed from Brassica rapa reference genome and InDel markers derived from whole-genome resequencing data of 94c9 and 92s105, BrRfp1 was mapped to a 12.6-kb region containing a potential candidate gene encoding pentatricopeptide repeat-containing protein. Based on the nucleotide polymorphisms of the candidate gene sequence between the restoring and nonrestoring alleles, a co-segregating marker SC718 was developed, which would be helpful for hybrid breeding by marker-assisted screening and for detecting new restorer lines.

  16. Novel tumorigenic rearrangement, Δrfp/ret, in a papillary thyroid carcinoma from externally irradiated patient

    International Nuclear Information System (INIS)

    Saenko, Vladimir; Rogounovitch, Tatiana; Shimizu-Yoshida, Yuki; Abrosimov, Aleksandr; Lushnikov, Eugeny; Roumiantsev, Pavel; Matsumoto, Naomichi; Nakashima, Masahiro; Meirmanov, Serik; Ohtsuru, Akira; Namba, Hiroyuki; Tsyb, Anatoly; Yamashita, Shunichi

    2003-01-01

    Molecular analysis of cDNA derived from a papillary thyroid carcinoma (PTC) (follicular variant of papillary thyroid carcinoma on histology) which developed in an externally irradiated patient 4 years after exposure identified a portion of the 5' region, exons 1-3, of the rfp gene juxtaposed upstream of the fragment encoding the tyrosine kinase (TK) domain of the ret gene. The fusion gene, termed Δrfp/ret, was the result of a balanced chromosomal translocation t(6;10) (p21.3;q11.2) confirmed by interphase FISH painting, with breakpoints occurring in introns 3 and 11 of the rfp and ret genes, respectively. Both Δrfp/ret and reciprocal ret/rfp chimeric introns had small deletions around breakpoints consistent with presumed misrepair of a radiation-induced double-strand DNA break underlying the rearrangement. No extensive sequence homology was found between the fragments flanking the breakpoints. The fusion protein retained the propensity to form oligomers likely to be mediated by a coiled-coil of the RFP polypeptide as assessed by a yeast two-hybrid system. NIH 3T3 fibroblasts stably transfected with a mammalian expression vector encoding full-length ΔRFP/RET readily gave rise to the tumors in athymic mice suggestive of high transforming potential of the fusion protein. Thus, the Δrfp/ret rearrangement may be causatively involved in cancerogenesis and provides additional evidence of the role of activated ret oncogene in the development of a subset of papillary thyroid carcinoma

  17. Novel tumorigenic rearrangement, {delta}rfp/ret, in a papillary thyroid carcinoma from externally irradiated patient

    Energy Technology Data Exchange (ETDEWEB)

    Saenko, Vladimir; Rogounovitch, Tatiana; Shimizu-Yoshida, Yuki; Abrosimov, Aleksandr; Lushnikov, Eugeny; Roumiantsev, Pavel; Matsumoto, Naomichi; Nakashima, Masahiro; Meirmanov, Serik; Ohtsuru, Akira; Namba, Hiroyuki; Tsyb, Anatoly; Yamashita, Shunichi

    2003-06-19

    Molecular analysis of cDNA derived from a papillary thyroid carcinoma (PTC) (follicular variant of papillary thyroid carcinoma on histology) which developed in an externally irradiated patient 4 years after exposure identified a portion of the 5' region, exons 1-3, of the rfp gene juxtaposed upstream of the fragment encoding the tyrosine kinase (TK) domain of the ret gene. The fusion gene, termed {delta}rfp/ret, was the result of a balanced chromosomal translocation t(6;10) (p21.3;q11.2) confirmed by interphase FISH painting, with breakpoints occurring in introns 3 and 11 of the rfp and ret genes, respectively. Both {delta}rfp/ret and reciprocal ret/rfp chimeric introns had small deletions around breakpoints consistent with presumed misrepair of a radiation-induced double-strand DNA break underlying the rearrangement. No extensive sequence homology was found between the fragments flanking the breakpoints. The fusion protein retained the propensity to form oligomers likely to be mediated by a coiled-coil of the RFP polypeptide as assessed by a yeast two-hybrid system. NIH 3T3 fibroblasts stably transfected with a mammalian expression vector encoding full-length {delta}RFP/RET readily gave rise to the tumors in athymic mice suggestive of high transforming potential of the fusion protein. Thus, the {delta}rfp/ret rearrangement may be causatively involved in cancerogenesis and provides additional evidence of the role of activated ret oncogene in the development of a subset of papillary thyroid carcinoma.

  18. RFP for the Auroral Multiscale Midex (AMM) Mission star tracker

    DEFF Research Database (Denmark)

    Riis, Troels; Betto, Maurizio; Jørgensen, John Leif

    1999-01-01

    This document is in response to the John Hopkins University - Applied Physics Laboratory RFP for the Auroral Multiscale Midex Mission star tracker.It describes the functionality, the requirements and the performance of the ASC Star Tracker.......This document is in response to the John Hopkins University - Applied Physics Laboratory RFP for the Auroral Multiscale Midex Mission star tracker.It describes the functionality, the requirements and the performance of the ASC Star Tracker....

  19. The RFP, A New Management Device for Pennsylvania

    Science.gov (United States)

    Jeffers, Donna A.

    1976-01-01

    Available from: EC 090 474. Reviewed are the guidelines set forth in the RFP (Request for Proposal) document regarding educational programs for adults and juveniles incarcerated in Pennsylvania institutions. (SBH)

  20. Initial results from the rebuilt EXTRAP T2R RFP device

    Science.gov (United States)

    Brunsell, P. R.; Bergsåker, H.; Cecconello, M.; Drake, J. R.; Gravestijn, R. M.; Hedqvist\\ad{2 }, A.; Malmberg, J.-A.

    2001-11-01

    The EXTRAP T2R thin shell reversed-field pinch (RFP) device has recently resumed operation after a major rebuild including the replacement of the graphite armour with molybdenum limiters, a fourfold increase of the shell time constant, and the replacement of the helical coil used for the toroidal field with a conventional solenoid-type coil. Wall-conditioning using hydrogen glow discharge cleaning was instrumental for successful RFP operation. Carbon was permanently removed from the walls during the first week of operation. The initial results from RFP operation with relatively low plasma currents in the range Ip = 70-100 kA are reported. RFP discharges are sustained for more than three shell times. Significant improvements in plasma parameters are observed, compared to operation before the rebuild. There is a substantial reduction in the carbon impurity level. The electron density behaviour is more shot-to-shot reproducible. The typical density is ne = 0.5-1×1019 m-3. Monitors of Hα line radiation indicate that the plasma wall interaction is more toroidally symmetric and that there is less transient gas release from the wall. The minimum loop voltage is in the range Vt = 28-35 V, corresponding to a reduction by a factor of two to three compared to the value before the rebuild.

  1. New chicken Rfp-Y haplotypes on the basis of MHC class II RFLP and MLC analyses

    DEFF Research Database (Denmark)

    Juul-Madsen, H R; Zoorob, R; Auffray, C

    1997-01-01

    New chicken Rfp-Y haplotypes were determined by the use of restriction fragment length polymorphism (RFLP) and mixed lymphocyte culture (MLC) in four different chicken haplotypes, B15, B19, B21, B201. The RFLP polymorphism was mapped to the Rfp-Y system by the use of a subclone (18.1) which maps...... near a polymorphic lectin gene located in the Rfp-Y system and DNA from families with known segregation of the implicated RFLP polymorphism. For the first time it is shown that major histocompatibility complex class II genes in the Rfp-Y system have functional implications. Sequence information...

  2. 75 FR 40856 - Federal Register Meeting Notice; Webinar About Regional Innovation Clusters RFP

    Science.gov (United States)

    2010-07-14

    ... potential Offerors about the Regional Innovation Clusters RFP. For more information please go to http://www.sba.gov/clusters/index.html . The RFP may be found on http://www.fedbizopps.gov . Logistical Information: The webinar will be held on Thursday, July 15, 2010. For details, please visit http://www.sba.gov...

  3. The reversed-field-pinch (RFP) fusion neutron source: A conceptual design

    International Nuclear Information System (INIS)

    Bathke, C.G.; Krakowski, R.A.; Miller, R.L.; Werley, K.A.

    1989-01-01

    The conceptual design of an ohmically heated, reversed-field pinch (RFP) operating at ∼5-MW/m 2 steady-state DT fusion neutron wall loading and ∼124-MW total fusion power is presented. These results are useful in projecting the development of a cost effective, low input power (∼206 MW) source of DT neutrons for large-volume (∼10 m 3 ), high-fluence (3.4 MW yr/m 2 ) fusion nuclear materials and technology testing. 19 refs., 15 figs., 9 tabs

  4. Refueling and control of RFP burns

    International Nuclear Information System (INIS)

    Nebel, R.; Miley, G.H.

    1978-01-01

    An earlier study of the stability of a fusion burn in a Reversed Field Pinch (RFP) has been extended to include cold particle refueling. This refueling, coupled with anomalous transport, makes possible quasi-steady state operation which both flattens the wall-loading temporal dependence and significantly increases energy gain factors. This paper discusses results of these burn simulations along with parametric studies aimed at determining associated reactor scaling problems

  5. RFP tags for labeling secretory pathway proteins

    Energy Technology Data Exchange (ETDEWEB)

    Han, Liyang; Zhao, Yanhua [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Zhang, Xi; Peng, Jianxin [College of Life Sciences, Central China Normal University, Wuhan 430079, Hubei (China); Xu, Pingyong, E-mail: pyxu@ibp.ac.cn [Key Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101 (China); Huan, Shuangyan, E-mail: shuangyanhuan@163.com [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Zhang, Mingshu, E-mail: mingshu1984@gmail.com [Key Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101 (China)

    2014-05-09

    Highlights: • Membrane protein Orai1 can be used to report the fusion properties of RFPs. • Artificial puncta are affected by dissociation constant as well as pKa of RFPs. • Among tested RFPs mOrange2 is the best choice for secretory protein labeling. - Abstract: Red fluorescent proteins (RFPs) are useful tools for live cell and multi-color imaging in biological studies. However, when labeling proteins in secretory pathway, many RFPs are prone to form artificial puncta, which may severely impede their further uses. Here we report a fast and easy method to evaluate RFPs fusion properties by attaching RFPs to an environment sensitive membrane protein Orai1. In addition, we revealed that intracellular artificial puncta are actually colocalized with lysosome, thus besides monomeric properties, pKa value of RFPs is also a key factor for forming intracellular artificial puncta. In summary, our current study provides a useful guide for choosing appropriate RFP for labeling secretory membrane proteins. Among RFPs tested, mOrange2 is highly recommended based on excellent monomeric property, appropriate pKa and high brightness.

  6. Pengaruh mimosa pada penyamakan kulit jaket domba samak nabati menggunakan sistem C-RFP, ditinjau dari sifat organoleptis, fisis, dan morfologi kulit

    Directory of Open Access Journals (Sweden)

    Sri Sutyasmi

    2016-06-01

    Full Text Available The purpose of this study was to determine the effect of the use of mimosa, to manufacture environmentally friendly leather for jacket by using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum, P=Powder, on physical, organoleptic, and morphology properties of leather. It was also to obtain a formula for vegetable tanning with C-RFP system. Pickled skins are conditioned (pre-tanning using Sodotan TSN and Sodotan APR, and then Sodotan TSN was chosen due to it meets the requirements of SNI leather for jacket (SNI 4593:2011. Then, pickled skins were tanned with mimosa and applied C-RFP system or rapid tanning without water added. Mimosa, used in this research, were 15%, 20%, and 25% and fatliquor were 12.5%, 15%, and 17.5%. Furthermore, The leather were finished into an environmentally friendly leather for jackets, and then tested for physical and organoleptic properties based on the SNI 4593:2011 as well as leather morphology (SEM. The physical test result shows that for mimosa 15%, 20% and 25%, and for fatliquor 15% and 17.5% are fullfill the SNI.

  7. Efektivitas penggunaan gambir sebagai bahan penyamak nabati sistem C-RFP untuk pembuatan kulit jaket dari kulit domba

    OpenAIRE

    Sri Sutyasmi

    2017-01-01

    Gambier is obtained from the extraction of leaves and young twigs of Uncaria gambir, a shrub that grows in Indonesia. Gambier contains tannin by 20% to 55% so that can be used as a vegetable tanning material using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum), P=Powder). This research aimed to determine the effectiveness of gambier as a vegetable tanning material using the C-RFP system. Pickled leather underwent a tanning process using the C-RFP system with gambier as the tanning m...

  8. Efektivitas Penggunaan Gambir Sebagai Bahan Penyamak Nabati Sistem C-RFP Untuk Pembuatan Kulit Jaket Dari Kulit Domba

    OpenAIRE

    Sutyasmi, Sri

    2017-01-01

    Gambier is obtained from the extraction of leaves and young twigs of Uncaria gambir, a shrub that grows in Indonesia. Gambier contains tannin by 20% to 55% so that can be used as a vegetable tanning material using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum), P=Powder). This research aimed to determine the effectiveness of gambier as a vegetable tanning material using the C-RFP system. Pickled leather underwent a tanning process using the C-RFP system with gambier as the tanning m...

  9. Fusion core start-up, ignition, and burn simulations of reversed-field pinch (RFP) reactors

    International Nuclear Information System (INIS)

    Chu, Y.Y.

    1988-01-01

    A transient reactor simulation model is developed to investigate and simulate the start-up, ignition, and burn of a reversed-field pinch reactor. The simulation is based upon a spatially averaged plasma balance model with field profiles obtained from MHD quasi-equilibrium analysis. Alpha particle heating is estimated from Fokker-Planck calculations. The instantaneous plasma current is derived from a self-consistent circuit analysis for plasma/coil/eddy current interactions. The simulation code is applied to the TITAN RFP reactor design which features a compact, high-power-density reversed-field pinch fusion system. A contour analysis is performed using the steady-state global plasma balance. The results are presented with contours of constant plasma current. A saddle point is identified in the contour plot which determined the minimum value of plasma current required to achieve ignition. In the simulations of the TITAN RFP reactor, the OH-driven super-conducting EF coils are found to deviate from the required equilibrium values as the induced plasma current increases. A set of basic results from the simulation of TITAN RFP reactor yield a picture of RFP plasma operation in a reactor. Investigations of eddy currents are also presented and have very important in reactor design

  10. Restriction Fragment Pattern (RFP) analysis of genomes from Danish isolates of Suid herpesvirus 1 (Aujeszky's disease virus)

    DEFF Research Database (Denmark)

    Christensen, Laurids Siig; Sørensen, K. J.; Lei, J. C.

    1987-01-01

    Purified DNA from 42 isolates of Suid herpesvirus 1 (SHV-1) collected during 1985 from clinical outbreaks of Aujezsky's disease on Danish farms was compared by restriction fragment pattern (RFP) analysis. The BamHI generated RFPs were found to be distinguishable, thus confirming RFP analysis...

  11. Simulation study of MHD relaxation and reconnection processes in RFP plasma

    International Nuclear Information System (INIS)

    Kusano, Kanya; Kunimoto, Kaito; Suzuki, Yoshio; Tamano, Teruo; Sato, Tetsuya

    1991-01-01

    The authors have studied several nonlinear processes in RFP plasma through the use of 3D MHD simulations. In particular, they have shed light on: (1) dynamo and self-sustainment in reversed-field pinch (RFP), (2) phase locking process in MHD relaxation, and (3) the heating and acceleration in magnetic reconnection process. First, the contributions of the kink (m = 1) mode (linearly unstable) and of the m = 0 mode (driven by nonlinear coupling) to the dynamo are qualitatively evaluated using a high accuracy simulation. It is found that, if the free energy to drive kink instabilities is as small as that in the actual experimental plasma, the m = 0 modes, driven nonlinearly, play a more important role for the flux generation than the kink modes. Secondly, numerical simulations of the self-sustainment process in a RFP are performed. It is confirmed that the self-sustainment process is a coherent oscillating process composed of the MHD relaxation and the resistive diffusion processes. Toroidal phase locking process of kink modes is numerically observed in simulations of self-reversal and self-sustainment processes. It has characteristics similar to the slinky mode observed in the OHTE experiment. A detailed investigation reveals that nonlinear coupling between the most unstable two kink modes governs the entire dynamics in all kink modes and leads to the phase locking process. They find that reconnection can accelerate plasma over a local Alfven speed. This is a result of the fact that the magnetic field in the downstream area plays a similar role to de Laval nozzle. They also investigate the heating mechanisms in reconnection process. It is revealed that the viscous heating rate is as large as the joule heating rate in the reconnection process. This result implies that the viscous heating in the reconnection process is an important candidate for the mechanism to explain the RFP experiments where the ion temperatures is higher than the electron temperature

  12. Magnetic measurements for RFP experiment on STP-3(M)

    International Nuclear Information System (INIS)

    Nagata, Akiyoshi; Tamaru, Takeshi; Arimoto, Hideki; Yamada, Shuichi; Sato, Koichi.

    1984-03-01

    Magnetic measurements are arranged for RFP experiment on STP-3(M). Magnetic measurements will be applied to investigate the discharge parameters, F(field reversal ratio) - theta(pinch parameter) diagram, the physical mechanism of flux enhancement and the toroidal and poloidal mode numbers due to the MHD instability. Theoretical considerations and instrumental techniques for magnetic measurements are described in detail. (author)

  13. Electron transport in the stochastic fields of RFP ZT-40M

    International Nuclear Information System (INIS)

    Punjabi, A.; Verma, A.; Kim, Myung-Hee; Boozer, A.

    1991-01-01

    In this paper, we use our newly developed Monte Carlo Method to study the transport of electrons in stochastic magnetic fields of the device RFP ZT4OM. The results of this calculation will be compared with the Rechester-Rosenbluth scaling

  14. Scrape-off model and pumped-limiter design for reversed-field pinches (RFP)

    International Nuclear Information System (INIS)

    Embrechts, M.J.; Bathke, C.G.; Krakowski, R.A.

    1983-01-01

    In order to develop a better understanding of the plasma/first-wall interaction in an RFP configuration, the models being developed to describe edgeplasma and scrapeoff regions for the tokamak have been adopted. Specifically, a scrapeoff model similar to the one developed and used for the tokamak FED design is used to model the parameter range where pumped limiters may be applied to the compact RFP. The one-dimensional, steady-state heat and particle equations are solved in the scrapeoff layer for an RFP geometry, assuming equal electron and ion temperature and density, convective transport along field lines, and Bohm-like diffusion. All charge-exchange and radiation effects are assumed to take place in the region between plasma and scrapeoff layer, and only a specific fraction of the total plasma energy will enter the scrapeoff layer in the form of conduction and convection. A simplified recycling model based on an effective recycling coefficient is used. For a given particle and energy flux entering the scrapeoff and for specified relationships between the particle flux and the energy flux near the first wall, the temperature and density profiles in the scrapeoff layer region are determined. The shape of the limiter surface is determined iteratively for a specified number of poloidal limiters by specifying a constant (design) heat flux for the limiter surfaces

  15. [Establishment of an iRFP and luciferase dual-color fluorescence-traced hepatocellular carcinoma transplantation model in nude mice].

    Science.gov (United States)

    Li, Hongjun; Yang, Tianhua; Huang, Yanping; Liu, Mingzhu; Qin, Zhongqiang; Chu, Fei; Li, Zhenghong; Li, Yonghai

    2017-11-01

    Objective To establish a hepatocellular carcinoma xenograft model in nude mice which could stably express gene and be monitored dynamically. Methods We first constructed the lentiviral particles containing luciferase (Luc) and near-infrared fluorescent protein (iRFP) and puromycin resistance gene, and then transduced them into the HepG2 hepatoma cells. The cell line stably expressing Luc and iRFP genes were screened and inoculated into nude mice to establish xenograft tumor model. Tumor growth was monitored using in vivo imaging system. HE staining and immunohistochemistry were used to evaluate the pathological features and tumorigenic ability. Results HepG2 cells stably expressing iRFP and Luc were obtained; with the engineered cell line, xenograft model was successfully established with the features of proper tumor developing time and high rate of tumor formation as well as typical pathological features as showed by HE staining and immunohistochemistry. Conclusion Hepatocellular carcinoma model in nude mice with the features of stable gene expression and dynamical monitoring has been established successfully with the HepG2-iRFP-Luc cell line.

  16. Confinement properties of the RFP [Reversed Field Pinch

    International Nuclear Information System (INIS)

    Weber, P.G.; Schoenberg, K.F.; Ingraham, J.C.; Miller, G.; Munson, C.P.; Pickrell, M.M.; Wurden; Tsui, H.Y.W.; Ritz, Ch.P.

    1990-01-01

    Research in ZT-40M has been focused on elucidating the confinement properties of the Reversed Field Pinch (RFP). Recent improvements in diagnostic capability have permitted measurement of radial profiles, as well as a detailed study of the edge plasma. The emerging confinement picture for ZT-40M has several ingredients: Typically 0.3 of the Ohmic input power to ZT-40M is available to drive fluctuations. Evidence points to this fluctuational power heating the ions. Approximately one quarter of the input power is lost through radiation, with metal impurities playing a key role. Magnetic fluctations in ZT-40M are at the percent level, as measured in the edge plasma. Extrapolating these data to small radii shows stochasticity in the core plasma. Suprathermal electrons are measured in the edge plasma. These electrons originate in the core, and transport to the edge along the fluctuating magnetic field lines. Under typical conditions, these electrons constitute the major electron energy loss channel in ZT-40M. Electrostatic fluctuations dominate the edge electron particle flux, but not the electron thermal flux. The major ion loss process is charge exchange, with smaller contributions from conduction and convection. In examining these observations, and the parametric dependences of confinement, a working model for RFP confinement emerges. An overview of this model, together with implications for the multi-mega-ampere ZTH experiment will be presented

  17. Pellet injection in the RFP (Reversed Field Pinch)

    Science.gov (United States)

    Wurden, G. A.; Weber, P. G.; Munson, C. P.; Cayton, T. E.; Bunting, C. A.; Carolan, P. G.

    Observation of pellets injected into the ZT-40M Reversed Field Pinch has allowed a new twist on the usual tokamak ablation physics modeling. The RFP provides a strong ohmic heating regime with relatively high electron drift parameter (xi sub drift approx. 0.2), in the presence of a highly sheared magnetic field geometry. In situ photos of the pellet ablation cloud using a grated-intensified CCD camera, as well as two-view integrated photos of the pellet trajectory show substantial modification of the original pellet trajectory, in both direction and speed. Depending on the launch geometry, increases in the initial 500 m/s pellet speed by 50 percent were observed, and a ski jump deflector plate in the launch port has been used to counteract strong poloidal curvature. In contrast to the tokamak, the D sub alpha light signature is strongest near the edge, and weaker in the plasma center. Additional information on ion temperature response to pellet injection with 20 microsec time resolution has been obtained using a 5-channel neutral particle analyzer (NPA). The energy confinement is transiently degraded while the beta is largely unchanged. This may be indicative of pellet injection into a high-beta plasma operating at fixed beta.

  18. Pellet injection in the RFP [Reversed Field Pinch

    International Nuclear Information System (INIS)

    Wurden, G.A.; Weber, P.G.; Munson, C.P.; Cayton, T.E.; Bunting, C.A.; Carolan, P.G.

    1988-01-01

    Observation of pellets injected into the ZT-40M Reversed Field Pinch has allowed a new twist on the usual tokamak ablation physics modeling. The RFP provides a strong ohmic heating regime with relatively high electron drift parameter (ξ/sub drift/ /approximately/ 0.2), in the presence of a highly sheared magnetic field geometry. In situ photos of the pellet ablation cloud using a grated-intensified CCD camera, as well as two-view integrated photos of the pellet trajectory show substantial modification of the original pellet trajectory, in both direction and speed. Depending on the launch geometry, increases in the initial 500 m/s pellet speed by 50% have been observed, and a ski jump deflector plate in the launch port has been used to counteract strong poloidal curvature. In contrast to the tokamak, the D/sub α/ light signature is strongest near the edge, and weaker in the plasma center. Additional information on ion temperature response to pellet injection with 20 μsec time resolution has been obtained using a 5-channel neutral particle analyzer (NPA). The energy confinement is transiently degraded while the beta is largely unchanged. This may be indicative of pellet injection into a high-beta plasma operating at fixed beta. 10 refs., 6 figs

  19. MHD activity during RFP startup in Extrap T1

    International Nuclear Information System (INIS)

    Drake, J.R.; Brzozowski, J.; Mazur, S.; Nordlund, P.

    1993-04-01

    During the startup phase of a reversed field pinch discharge (RFP), the configuration undergoes relaxation which is the dynamic process by which the configuration evolves to states near the minimum magnetic energy thus realising improved stability. A high loop voltage and a high level of level of m =1 poloidal mode activity is observed while this process occurs. After the RFP configuration is established, there is a substantial decrease in both the m = 1 activity and the loop voltage. In addition in the Extrap T1 device, under unfavourable conditions characterised by a pinch parameter θ less than about 1.5 at the time of reversal, the loop voltage can further increase substantially resulting in a suppressed plasma current level. Simultaneous with the loop voltage increase there is an observed increase in poloidal m = 0 mode activity. This occurs just when field reversal first is established as the surface with zero toroidal field is produced at the plasma edge. The increased loop voltage is believed to be the result of m = 0 tearing modes resonant at the reversal surface and driven by a large parallel current gradient at the edge which become particularly pathological when the θ, is comparatively low

  20. Measurements of fast ion spatial dynamics during magnetic activity in the RFP

    Science.gov (United States)

    Goetz, J. A.; Anderson, J. K.; Bonofiglo, P.; Kim, J.; McConnell, R.; Magee, R. M.

    2017-10-01

    Fast ions in the RFP are only weakly affected by a stochastic magnetic field and behave nearly classically in concentration too low to excite Alfvenic activity. At high fast ion concentration sourced by H-NBI in 300kA RFP discharges, a substantial drop in core-localized high pitch fast ions is observed during bursts of coupled EPM and IAE (magnetic island-induced Alfven eigenmode) activity (100-200kHz) through neutral particle analysis. Sourcing instead fast deuterium with NBI, the DD fusion products can measure the dynamics of the fast ion density profile. Both a collimated neutron detector and a new 3MeV fusion proton detector loaned by TriAlpha Energy measure the fast ion density profile with 5cm spatial resolution and 100 μs temporal resolution. In D-NBI, the bursting EPM is excited at slightly lower frequency and the IAE activity is nearly absent, likely due to an isotope effect and loss of wave-particle interaction. In these cases, neutral particle analysis shows little change in the core-localized high pitch fast ion content, and the fusion product profile indicates little change in the fast ion density profile, leaving unexplained the mechanism removing EPM drive. We measure a substantial redistribution of the fast ion profile due to strong lower-frequency ( 30kHz) MHD activity that accompanies the current profile relaxation in the RFP. Profile flattening is strongest in low bulk density discharges, which often occur with a total increase in global neutron flux from acceleration of the beam ions. Work supported by US DoE.

  1. Next-Step scientific objectives, targets, and parameters for reversed-field-pinch (RFP) magnetic fusion energy (MFE) systems: Preliminary thoughts

    International Nuclear Information System (INIS)

    Krakowski, R.A.; Bathke, C.G.; DiMarco, J.N.; Miller, R.L.; Werley, K.A.

    1993-01-01

    The purpose of this document is the quantitative definition of objectives, targets, and parameters of the Next-Step device to follow the present RFX experiment; this device is given the name RFXNS. Although developed over five years ago, much of the material distilled into the 1988 RFP tactical plan is useful in establishing the goals and parameters of RFXNS. This earlier plan established tentative parameters of an RFP next step based on: predictions of RFP ignition and commercial-reactor devices; and the assumed successful operation of highly complementary RFP experiments RFX and ZTH/CPRF. Programmatic changes and evolution that have occurred since 1988 strongly impact the role and characteristics of an RFXNS: the Los Alamos ZTH/CPRF project and fusion program was terminated in mid-construction for reasons of MFE cost savings and concept focusing; great progress has been made in launching ITER; and reactor projections for the tokamak have increased in detail and variety, but not in commercial promise and competitiveness. A brief status of and perspective from each of the above three points is necessary before the key issues and their implementation to form the basis of the RFXNS definition are given

  2. First molecular identification of the transgene red fluorescent protein (RFP in transgenic ornamental zebrafish (Danio rerio introduced in Peru

    Directory of Open Access Journals (Sweden)

    Carlos Scotto

    2013-09-01

    Full Text Available In this paper the transgenic fluorescent red, orange and pink zebra fish (Danio rerio, found in local aquariums in Peru, were identified using the PCR technique to amplify the transgene RFP sea anemone belonging to Discosoma spp. The gene expression of the red fluorescent protein (RFP transgene was found to determine different gradients-of-bioluminescence (shades in color in each GMO fish analyzed. We performed sequence analysis of the two variants of the RFP along with six variants of the existing fluorescent protein GFP from the Genbank, this could help identify quickly if they are new genes or variants thereof as these novel fluorescent proteins may be introduced in aquatic GMO in the future. Thus, developing and improving biosecurity measures through its timely detection at the molecular genetic level.

  3. Suppression of m = 0 in a RFP by toroidal field coils

    International Nuclear Information System (INIS)

    Alexander, D.; Robertson, S.

    1993-01-01

    The Reversatron RFP is normally operated with the toroidal field coils connected in series. The time-integrated voltage applied to the circuit determines the sum of the fluxes linking each turn but not the flux within each turn. Each winding may have a different flux determined by the external drive and by currents within the plasma. A parallel connection of the field coils results in the flux within each coil being determined by the volt-seconds applied to the windings; thus the toroidal flux is the same within each coil. This configuration suppresses any toroidal variation in the toroidal flux and effectively reduces the level of the m = 0 component of the radial field. The m = 0 fluctuations are expected to arise due to nonlinear coupling of the m = 1 modes. A parallel connection of field coils is impractical due to the low impedance required for driving the coils. The authors have tested the effect of parallel connected coils by adding an auxiliary set of 36 coils. These are connected in parallel but are not connected to any supply. The toroidal flux is generated by the series-connected coils which generate voltage but not current in the parallel-connected coils. With the auxiliary coils, the discharge duration is increased from 500 to 550 μsec, the plasma current is increased from 50 kA to 60 kA, F is more negative, Θ is larger, and there is less shot-to-shot variation in the discharges. The m = 0 fluctuations measured by 43 surface coils are, however, only slightly reduced

  4. Effects of pulsed electric field on ULQ and RFP plasmas

    International Nuclear Information System (INIS)

    Watanabe, M.; Saito, K.; Suzuki, T.

    1997-01-01

    Dynamo activity and self-organization processes are investigated using the application of pulsed poloidal and toroidal electric fields on ULQ and RFP plasmas. Synchronized to the application of the pulsed electric fields, the remarkable responses of the several plasma parameters are observed. The plasma has a preferential magnetic field structure, and the external perturbation activates fluctuation to maintain the structure through dynamo effect. This process changes the total dissipation with the variation of magnetic helicity in the system, showing that self organization accompanies an enhanced dissipation. (author)

  5. Experimental scaling of fluctuations and confinement with Lundquist number in the RFP

    International Nuclear Information System (INIS)

    Stoneking, M.R.; Chapman, J.T.; Prager, S.C.; Sarff, J.S.

    1997-09-01

    The scaling of the magnetic and velocity fluctuations with Lundquist number (S) is examined experimentally over a range of values from 7 x 10 4 to 10 6 in a reversed field pinch (RFP) plasma. Magnetic fluctuations do not scale uniquely with the Lundquist number. At high (relative) density, fluctuations scale as b∝S -0.18 , and fluctuations are almost independent of S at low relative density, b∝S -0.07 ; however both exponents fall in the range of theoretical and numerical predictions. At high relative density, the scaling of the energy confinement time follows expectations for transport in a stochastic magnetic field. A confinement scaling law (nτ E ∝β 4/5 T -7/10 A -3/5 I φ 2 ) is derived assuming the persistent dominance of stochastic magnetic diffusion in the RFP and on the measured scaling of magnetic fluctuations. The peak velocity fluctuations during a sawtooth cycle scale marginally stronger than magnetic fluctuations but weaker than a simple Ohm's law prediction. The sawtooth period is determined by a resistive-Alfvenic hybrid time (T saw ∝√(τ R τ Alf )) rather than a purely resistive time

  6. R/L, a double reporter mouse line that expresses luciferase gene upon Cre-mediated excision, followed by inactivation of mRFP expression.

    Science.gov (United States)

    Jia, Junshuang; Lin, Xiaolin; Lin, Xia; Lin, Taoyan; Chen, Bangzhu; Hao, Weichao; Cheng, Yushuang; Liu, Yu; Dian, Meijuan; Yao, Kaitai; Xiao, Dong; Gu, Weiwang

    2016-10-01

    The Cre/loxP system has become an important tool for the conditional gene knockout and conditional gene expression in genetically engineered mice. The applications of this system depend on transgenic reporter mouse lines that provide Cre recombinase activity with a defined cell type-, tissue-, or developmental stage-specificity. To develop a sensitive assay for monitoring Cre-mediated DNA excisions in mice, we generated Cre-mediated excision reporter mice, designated R/L mice (R/L: mRFP(monomeric red fluorescent protein)/luciferase), express mRFP throughout embryonic development and adult stages, while Cre-mediated excision deletes a loxP-flanked mRFP reporter gene and STOP sequence, thereby activating the expression of the second reporter gene luciferase, as assayed by in vivo and ex vivo bioluminescence imaging. After germ line deletion of the floxed mRFP and STOP sequence in R/L mice by EIIa-Cre mice, the resulting luciferase transgenic mice in which the loxP-mRFP-STOP-loxP cassette is excised from all cells express luciferase in all tissues and organs examined. The expression of luciferase transgene was activated in liver of RL/Alb-Cre double transgenic mice and in brain of RL/Nestin-Cre double transgenic mice when R/L reporter mice were mated with Alb-Cre mice and Nestin-Cre mice, respectively. Our findings reveal that the double reporter R/L mouse line is able to indicate the occurrence of Cre-mediated excision from early embryonic to adult lineages. Taken together, these findings demonstrate that the R/L mice serve as a sensitive reporter for Cre-mediated DNA excision both in living animals and in organs, tissues, and cells following necropsy.

  7. Pengaruh Mimosa Pada Penyamakan Kulit Jaket Domba Samak Nabati Menggunakan Sistem C-RFP, Ditinjau Dari Sifat Organoleptis, Fisis, Dan Morfologi Kulit

    OpenAIRE

    Sutyasmi, Sri; Widowati, Titik Purwati; Setyadewi, Noor Maryam

    2016-01-01

    The purpose of this study was to determine the effect of the use of mimosa, to manufacture environmentally friendly leather for jacket by using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum), P=Powder), on physical, organoleptic, and morphology properties of leather. It was also to obtain a formula for vegetable tanning with C-RFP system. Pickled skins are conditioned (pre-tanning) using Sodotan TSN and Sodotan APR, and then Sodotan TSN was chosen due to it meets the requirements of...

  8. Pengaruh mimosa pada penyamakan kulit jaket domba samak nabati menggunakan sistem C-RFP, ditinjau dari sifat organoleptis, fisis, dan morfologi kulit

    OpenAIRE

    Sri Sutyasmi; Titik Purwati Widowati; Noor Maryam Setyadewi

    2016-01-01

    The purpose of this study was to determine the effect of the use of mimosa, to manufacture environmentally friendly leather for jacket by using the C-RFP system (C=Conditioning, R=Rapid, F=Fass (drum), P=Powder), on physical, organoleptic, and morphology properties of leather. It was also to obtain a formula for vegetable tanning with C-RFP system. Pickled skins are conditioned (pre-tanning) using Sodotan TSN and Sodotan APR, and then Sodotan TSN was chosen due to it meets the requirements of...

  9. Thermostructural design of the first wall/blanket for the TITAN-RFP fusion reactor

    International Nuclear Information System (INIS)

    Orient, G.E.; Blanchard, J.P.; Ghoniem, N.M.

    1987-01-01

    The mass power density, which is defined as the average power per unit mass within the magnet boundary, is a rough and general measure of economic competitiveness. Conn et al. (1985) have identified a target value of 100 kW(e)/tonne as a reasonable threshold for 'compact' commercial fusion systems. In pursuit of this goal, Hagenson et al. (1984) and Najmabadi et al. (1987) have pointed out the inherent characteristics of the RFP toroidal confinement concept which allow it to exceed this target value. It is inevitable that the compactness of the fusion power core will introduce a unique set of design issues. The special design concerns stem from high thermal surface fluxes, high bulk energy deposition by neutrons, and a relatively short blanket structural lifetime. In the TITAN-RFP, study Najmabadi et al. (1987) investigate a number of blanket (B) and first wall (FW) options suitable for high power density fusion reactors. Final choices were made for two designs: A high pressure aqueous blanket and a vanadium/lithium self-cooled blanket. The first design utilizes a pressurized aqueous loop containing a lithium compound dissolved in water, while the second design is based upon a self-cooled lithium-vanadium blanket. In this paper, we consider the beginning-of-life (BOL) thermostructural design and analysis of only the second concept. (orig./GL)

  10. Field error reduction experiment on the REPUTE-1 RFP device

    International Nuclear Information System (INIS)

    Toyama, H.; Shinohara, S.; Yamagishi, K.

    1989-01-01

    The vacuum chamber of the RFP device REPUTE-1 is a welded structure using 18 sets of 1 mm thick Inconel bellows (inner minor radius 22 cm) and 2.4 mm thick port segments arranged in toroidal geometry as shown in Fig. 1. The vacuum chamber is surrounded by 5 mm thick stainless steel shells. The time constant of the shell is 1 ms for vertical field penetration. The pulse length in REPUTE-1 is so far 3.2 ms (about 3 times longer than shell skin time). The port bypass plates have been attached as shown in Fig. 2 to reduce field errors so that the pulse length becomes longer and the loop voltage becomes lower. (author) 5 refs., 4 figs

  11. Studies on mycobacterium tuberculosis sensitivity test by using the method of rapid radiometry with appendixes of clinical results

    International Nuclear Information System (INIS)

    Yang Yongqing; Jiang Yimin; Lu Wendong; Zhu Rongen

    1987-01-01

    Three standard strains of mycobacterium tuberculosis (H 37 RV-fully sensitive, SM-R1000 μg/ml, RFP-R 100 μg/ml) were tested with 10 concentration of 5 antitubercular agent, INH, SM, PAS, RFP and EB. 114 isolates of mycobacterium tuberculosis taken from patients were tested with INH, PAS, SM and RFP. They were agreed with the results of standard Lowenstein-Jensen method in 81.7%. 82% of the isolate test were completed within 5 days. The method may be used in routine clinical work. The liquid media prepared by authors do not require human serum albumin and it is less expensive and readily available

  12. SAP crm integration testing

    OpenAIRE

    Černiavskaitė, Marija

    2017-01-01

    This Bachelor's thesis presents SAP CRM and integration systems testing analysis: investigation in SAP CRM and SAP PO systems, presentation of relationship between systems, introduction to third-party system (non-SAP) – Network Informational System (NIS) which has integration with SAP, presentation of best CRM testing practises, analysis and recommendation of integration testing. Practical integration testing is done in accordance to recommendations.

  13. The SIMPSONS project: An integrated Mars transportation system

    Science.gov (United States)

    Kaplan, Matthew; Carlson, Eric; Bradfute, Sherie; Allen, Kent; Duvergne, Francois; Hernandez, Bert; Le, David; Nguyen, Quan; Thornhill, Brett

    In response to the Request for Proposal (RFP) for an integrated transportation system network for an advanced Martian base, Frontier Transportation Systems (FTS) presents the results of the SIMPSONS project (Systems Integration for Mars Planetary Surface Operations Networks). The following topics are included: the project background, vehicle design, future work, conclusions, management status, and cost breakdown. The project focuses solely on the surface-to-surface transportation at an advanced Martian base.

  14. LASER BIOLOGY AND MEDICINE: Application of laser fluorimetry for determining the influence of a single amino-acid substitution on the individual photophysical parameters of a fluorescent form of a fluorescent protein mRFP1

    Science.gov (United States)

    Banishev, A. A.; Vrzheshch, E. P.; Shirshin, E. A.

    2009-03-01

    Individual photophysical parameters of the chromophore of a fluorescent protein mRFP1 and its two mutants (amino-acid substitution at position 66 - mRFP1/ Q66C and mRFP1/Q66S proteins) are determined. For this purpose, apart from conventional methods of fluorimetry and spectrophotometry, nonlinear laser fluorimetry is used. It is shown that the individual extinction coefficients of the chromophore of proteins correlate (correlation coefficient above 0.9) with the volume of the substituted amino-acid residue at position 66 (similar to the positions of the absorption, fluorescence excitation and emission maxima).

  15. Reducing and measuring fluctuations in the MST RFP: Enhancement of energy confinement and measurement of the MHD dynamo

    International Nuclear Information System (INIS)

    Den Hartog, D.J.; Almagri, A.F.

    1996-09-01

    A three- to five-fold enhancement of the energy confinement time in a reversed-field pinch (RFP) has been achieved in the Madison Symmetric Torus (MST) by reducing the amplitude of tearing mode fluctuations responsible for anomalous transport in the core of the RFP. By applying a transient poloidal inductive electric field to flatten the current density profile, the fluctuation amplitude b/B decreases from 1.5% to 0.8%, the electron temperature T e0 increases from 250 eV to 370 eV, the ohmic input power decreases from 4.5 MW to approximately 1.5 MW, the poloidal beta β 0 increases from 6% to 9%, and the energy confinement time τ E increases from 1 ms to ∼5 ms in I φ = 340 kA plasmas with density n = 1 x 10 19 m -3 . Current profile control methods are being developed for the RFP in a program to eliminate transport associated with these current-gradient-driven fluctuations. In addition to controlling the amplitude of the tearing modes, we are vigorously pursuing an understanding of the physics of these fluctuations. In particular, plasma flow, both equilibrium and fluctuating, plays a critical role in a diversity of physical phenomena in MST. The key results: 1) Edge probe measurements show that the MHD dynamo is active in low collisionality plasmas, while at high collisionality a new mechanism, the 'electron diamagnetic dynamo,' is observed. 2) Core spectroscopic measurements show that the toroidal velocity fluctuations of the plasma are coherent with the large-scale magnetic tearing modes; the scalar product of these two fluctuating quantities is similar to that expected for the MHD dynamo electromotive force. 3) Toroidal plasma flow in MST exhibits large radial shear and can be actively controlled, including unlocking locked discharges, by modifying E r with a robust biased probe. 24 refs

  16. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  17. Heterogeneous transgene expression in the retinas of the TH-RFP, TH-Cre, TH-BAC-Cre and DAT-Cre mouse lines.

    Science.gov (United States)

    Vuong, H E; Pérez de Sevilla Müller, L; Hardi, C N; McMahon, D G; Brecha, N C

    2015-10-29

    Transgenic mouse lines are essential tools for understanding the connectivity, physiology and function of neuronal circuits, including those in the retina. This report compares transgene expression in the retina of a tyrosine hydroxylase (TH)-red fluorescent protein (RFP) mouse line with three catecholamine-related Cre recombinase mouse lines [TH-bacterial artificial chromosome (BAC)-, TH-, and dopamine transporter (DAT)-Cre] that were crossed with a ROSA26-tdTomato reporter line. Retinas were evaluated and immunostained with commonly used antibodies including those directed to TH, GABA and glycine to characterize the RFP or tdTomato fluorescent-labeled amacrine cells, and an antibody directed to RNA-binding protein with multiple splicing to identify ganglion cells. In TH-RFP retinas, types 1 and 2 dopamine (DA) amacrine cells were identified by their characteristic cellular morphology and type 1 DA cells by their expression of TH immunoreactivity. In the TH-BAC-, TH-, and DAT-tdTomato retinas, less than 1%, ∼ 6%, and 0%, respectively, of the fluorescent cells were the expected type 1 DA amacrine cells. Instead, in the TH-BAC-tdTomato retinas, fluorescently labeled AII amacrine cells were predominant, with some medium diameter ganglion cells. In TH-tdTomato retinas, fluorescence was in multiple neurochemical amacrine cell types, including four types of polyaxonal amacrine cells. In DAT-tdTomato retinas, fluorescence was in GABA immunoreactive amacrine cells, including two types of bistratified and two types of monostratified amacrine cells. Although each of the Cre lines was generated with the intent to specifically label DA cells, our findings show a cellular diversity in Cre expression in the adult retina and indicate the importance of careful characterization of transgene labeling patterns. These mouse lines with their distinctive cellular labeling patterns will be useful tools for future studies of retinal function and visual processing. Published by Elsevier

  18. Confinement studies of a high current density RFP in the Extrap T1 Upgrade device

    International Nuclear Information System (INIS)

    Drake, J.R.; Brzozowski, J.H.; Brunsell, P.; Hellblom, G.; Karlsson, P.; Mazur, S.; Nordlund, P.; Welander, A.; Zastrow, K.D.

    1992-01-01

    Confinement studies have been carried out on the Extrap T1 device operated in the reversed field pinch (RFP) mode. Extrap T1 is a small device with a major radius of R=0.5 m and a high aspect ratio, R/a=8.9. For these experiments, the device has been operated with a resistive shell with measured, toroidally-averaged flux penetration times of τ sv = 500μs (vertical) and τ sR =300μs (radial). The pulse lengths are about 600 μs, which is slightly longer than the shell penetration time. The purpose of these experiments is to study energy confinement in a high aspect-ratio, high current-density RFP device with a resistive shell. The device can be operated with high current densities which exceed 20 MAm -2 on axis. For these discharges, the average electron density is relatively high, ≅ 1x10 20 m -3 . Therefore, although the average current density exceeds 5 MAm -2 , the important parameter / ≅ I/N is maintained less than 1x10 -13 Am, where N is the line density. The plasma diagnostics for the device include a single chord CO 2 laser interferometer ( ), single point Thomson scattering (T e , n o ), VUV and visible spectroscopy (T e , Z eff ) surface barrier diodes for soft X-ray measurements (T e ), bolometry (P rad ), surface probes (Γ p ,T i ) and comprehensive magnetic diagnostics for both equilibrium and magnetic fluctuation studies. (author) 5 refs., 1 fig., 1 tab

  19. Energy and Pitch Distribution of Spontaneously-generated High-energy Bulk Ions in the RFP

    Science.gov (United States)

    Kim, Jungha; Anderson, Jay; Reusch, Joshua; Eilerman, Scott; Capecchi, William

    2014-10-01

    Magnetic reconnection events in the reversed field pinch (RFP) are known to heat bulk and impurity ions. Runaway due to a parallel electric field has recently been confirmed as an important acceleration mechanism for high energy test ions supplied by a neutral beam. This effect does not, however, explain the change in distribution of nearly Maxwellian bulk ions at a reconnection event. By operating MST near maximum current and low electron density, significant fusion neutron flux can be generated without neutral beam injection. The bulk ion distribution created in these plasmas is well-confined, non-Maxwellian, and can be measured by the Advanced Neutral Particle Analyzer (ANPA) placed at a radial or tangential porthole. Data show a high energy tail up to 25 keV with a relatively higher signal in the low energy channels (8-15 keV) at the radial port following a reconnection event. Analysis of the energy dependence of trapped orbits sampled by the ANPA at the radial view implies an abundance of lower energy particles in regions of higher neutral density. This mandates a careful deconvolution of the measured ANPA signal to compute the fast ion distribution. This work is supported by the US DOE and NSF.

  20. Primera identificación molecular del transgen de la proteína fluorescente roja (RFP en peces Cebra (Danio rerio transgénicos ornamentales introducidos en el Perú

    Directory of Open Access Journals (Sweden)

    Carlos Scotto

    2013-01-01

    Full Text Available En el presente trabajo se identificó por primera vez peces Cebra transgénicos (Danio rerio fluorescentes de color rojo, naranja y rosado introducidos al territorio peruano de acuarios locales utilizando la técnica de PCR para amplificar el transgen RFP perteneciente a la anémona marina Discosoma spp. Se encontró una expresión génica diferencial del transgen de la proteína fluorescente roja (RFP que determinaría una gradiente de bioluminiscencia para cada color entre los peces OVM analizados. Se realizó un análisis de secuencias de las dos variantes de la RFP junto con las seis variantes de la GFP de proteínas fluorescentes existentes en el Genbank que podrían ayudar a identificar rápidamente si son nuevos genes o si son nuevas variantes de éstas proteínas fluorescentes y que podrían ser utilizadas en otros OVMs hidrobiológicos a futuro. De este modo, desarrollar y optimizar las medidas de bioseguridad mediante su oportuna detección a nivel genético molecular.

  1. Integrating NRDA and CERCLA environmental evaluations at the Rocky Flats Plant: A case study

    International Nuclear Information System (INIS)

    Knudsen, T.L.

    1993-01-01

    The purpose of this paper is to briefly review cleanup regulations in reference to natural resource liability, protection, and restoration; to present a case study on the Rocky Flats Plant (RFP) showing how this DOE facility is approaching the task of integrating the ecological assessment/impact portion of three major regulatory mandates: Resource Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation and Liability Act (CERCLA), and the National Environmental Policy Act (NEPA) with the Natural Resource Damage Assessment (NRDA) regulations using a flow chart depicting RCRA/CERCLA interim and final actions; to present what has and has not worked at the RFP; and, finally to suggest some technical strategies when planning for remediation and restoration in the NRD process that should be considered

  2. Integrated test schedule for buried waste integrated demonstration

    International Nuclear Information System (INIS)

    Brown, J.T.; McDonald, J.K.

    1992-05-01

    The Integrated Test Schedule incorporates the various schedules the Buried Waste Integrated Demonstration (BWID) supports into one document. This document contains the Federal Facilities Agreement and Consent Order schedules for the Idaho National Engineering Laboratory, Hanford Reservation, Oak Ridge Reservation, and Fernald Environmental Materials Center. Included in the Integrated Test Schedule is the Buried Waste Integrated Demonstration ''windows of opportunity'' schedule. The ''windows of opportunity'' schedule shows periods of time in which Buried Waste Integrated Demonstration Program-sponsored technology demonstrations could support key decisions in the Federal Facilities Agreement and Consent Order. Schedules for the Buried Waste Integrated Demonstration-sponsored technology task plans are categorized by technology area and divided by current fiscal year and out-year. Total estimated costs for Buried Waste Integrated Demonstration-sponsored Technology Task Plans for FY-92 through FY-97 are $74.756M

  3. UAS Integration in the NAS Project: Integrated Test and Evaluation (IT&E) Flight Test 3. Revision E

    Science.gov (United States)

    Marston, Michael

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  4. Demonstration, testing and evaluation of nonintrusive characterization technologies at operable Unit 2 of Rocky Flats Plant. Final report

    International Nuclear Information System (INIS)

    1994-09-01

    A three-dimensional (3-D), high-resolution (HR) seismic reflection evaluation was conducted at the Rocky Flats Plant (RFP), near Golden, Colorado, to demonstrate the applicability of nonintrusive characterization techniques to detect buried objects, contamination, and geological/hydrological features at RFP. The evaluation was conducted as part of the U.S. Department of Energy's (DOE) request for demonstration, testing and evaluation (DT ampersand E) of nonintrusive techniques, under DOE Program Research and Development Announcement (PRDA) No. DE-RA05-09OR22000

  5. Demonstration, testing and evaluation of nonintrusive characterization technologies at operable Unit 2 of Rocky Flats Plant. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    A three-dimensional (3-D), high-resolution (HR) seismic reflection evaluation was conducted at the Rocky Flats Plant (RFP), near Golden, Colorado, to demonstrate the applicability of nonintrusive characterization techniques to detect buried objects, contamination, and geological/hydrological features at RFP. The evaluation was conducted as part of the U.S. Department of Energy`s (DOE) request for demonstration, testing and evaluation (DT&E) of nonintrusive techniques, under DOE Program Research and Development Announcement (PRDA) No. DE-RA05-09OR22000.

  6. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    Science.gov (United States)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  7. Particle and energy balance in the SOL generated by a limiter in a RFP plasma

    International Nuclear Information System (INIS)

    Antoni, V.; Bagatin, M.; Desideri, D.; Serianni, G.

    1992-01-01

    The plasma outer region of the RFP experiment ETA BETA II has been extensively investigated. In particular by an insertable graphite limiter, instrumented with thermocouples and Langmuir probes, the energy and particle fluxes in the shadow of the limiter have been measured at different insertions. The results are compared with those obtained by small-sized calorimeter/Langmuir probes inserted to investigate, with fine space resolution, the outer region without limiter. Almost 80% of the power to the limiter is estimated to be carried by fast suprathermal electrons flowing along the magnetic field line direction. From an energy balance equation, applied in the SOL locally generated, the connection length of the limiter has been derived. Thus a particle balance has been applied to determine the particle diffusion coefficient at the plasma edge. (orig.)

  8. Initial reversed-field pinch experiments on ZT-40 and recent advances in RFP theory

    International Nuclear Information System (INIS)

    Baker, D.A.; Buchenauer, C.J.; Burkhardt, L.C.

    1980-01-01

    The ZT-40 reversed-field pinch (RFP) has been operated in several modes: (1) without reversed toroidal field, (2) with self reversal, and (3) with aided reversal. An analytic ohmic heating and ignition model both confirm and provide guidance for transport codes. Nondissipative formation schemes have been analyzed and ideal MHD stable evolution and burn scenarios have been found. Particle and fluid simulations have produced qualitative agreement with respect to the nonlinear behavior of m = 0 resistive g-modes. Helical ohmic reversed field states are produced by a 2-D dynamical simulation, and nonlinear analytic work describes the final state. A fast resistive MHD code for linear stability has clarified the relations between several kinds of resistive instabilities. Ballooning modes and g-modes in systems with arbitrary magnetic shear including resistivity and viscosity, have been studied in a unified treatment with growth rate vs wavenumber showing the existence of important cutoffs

  9. Integration testing through reusing representative unit test cases for high-confidence medical software.

    Science.gov (United States)

    Shin, Youngsul; Choi, Yunja; Lee, Woo Jin

    2013-06-01

    As medical software is getting larger-sized, complex, and connected with other devices, finding faults in integrated software modules gets more difficult and time consuming. Existing integration testing typically takes a black-box approach, which treats the target software as a black box and selects test cases without considering internal behavior of each software module. Though it could be cost-effective, this black-box approach cannot thoroughly test interaction behavior among integrated modules and might leave critical faults undetected, which should not happen in safety-critical systems such as medical software. This work anticipates that information on internal behavior is necessary even for integration testing to define thorough test cases for critical software and proposes a new integration testing method by reusing test cases used for unit testing. The goal is to provide a cost-effective method to detect subtle interaction faults at the integration testing phase by reusing the knowledge obtained from unit testing phase. The suggested approach notes that the test cases for the unit testing include knowledge on internal behavior of each unit and extracts test cases for the integration testing from the test cases for the unit testing for a given test criteria. The extracted representative test cases are connected with functions under test using the state domain and a single test sequence to cover the test cases is produced. By means of reusing unit test cases, the tester has effective test cases to examine diverse execution paths and find interaction faults without analyzing complex modules. The produced test sequence can have test coverage as high as the unit testing coverage and its length is close to the length of optimal test sequences. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Overview of Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davies, Francis

    2018-01-01

    This presentation describes the basic philosophy behind integrated testing and partially integrated testing. It lists some well known errors in space systems that were or could have been caught during integrated testing. Two examples of integrated testing at the Johnson Space Center (JSC) are mentioned, and then an overview of two test facilities that do power testing (partially integrated testing) at JSC are presented, with information on the capabilities of each. Finally a list of three projects that has problems caught during power quality or Electromagnetic Interference (EMI) testing is presented.

  11. Integration and test planning patterns in different organizations

    NARCIS (Netherlands)

    Jong, de I.S.M.; Boumen, R.; Mortel - Fronczak, van de J.M.; Rooda, J.E.; Tretmans, J.

    2007-01-01

    Planning an integration and test phase is often done by experts in the visited organizations. These experts have a thorough knowledge about the system, integration and testing and the business drivers of an organization. An integration and test plan developedfor an airplane is different than the

  12. Actinide integral measurements in the CFRMF and integral tests for ENDF/B-V

    International Nuclear Information System (INIS)

    Anderl, R.A.

    1982-01-01

    Integral capture and/or fission rates have been reported earlier for several actinides irradiated in the fast neutron field of the Coupled Fast Reactivity Measurements Facility (CFRMF). These nuclides include 232 Th, 233 U, 235 U, 238 U, 237 Np, 239 Pu, 240 Pu, 242 Pu, 241 Am and 243 Am. This paper forucses on the utilization of these integral data for testing the respective cross sections on ENDF/B-V. Integral cross sections derived from the measured reaction rates are tabulated. Results are presented for cross-section data testing which includes integral testing based on a comparison of calculated and measured integral cross sections and testing based on least-squares-adjustment analyses

  13. Radial transport effects on ECCD in the TCV and DIII-D tokamaks and on Ohmic discharges in the MST RFP

    International Nuclear Information System (INIS)

    Harvey, R.W.; Sauter, O.; Nikkola, P.; Prater, R.; O'Connell, R.; Forest, C.B.

    2003-01-01

    The comprehensive CQL3D Fokker-Planck/Quasilinear simulation code has been benchmarked against experiment over a wide range of electron cyclotron conditions in the DIII-D tokamak (C.C. Petty et al., 14. Topical Conf. on RF Power in Plasmas, 2002). The same code, in disagreement with experiment, gives 560 kA of ECCD for a well documented, completely ECCD-driven, 100 kA TCV shot [O. Sauter et al, PRL, 2000]. Recent work (R.W. Harvey et al, Phys. Rev. Lett., 2002) has resolved the differences as due to radial transport at a level closely consistent with ITER scaling. Transport does not substantially affect DIII-D ECCD, but at similar ECH power has an overwhelming effect on the much smaller TCV. The transport is consistent with electrostatic-type diffusion (D ρρ constant in velocity space) and not with a magnetic-type diffusion (D ρρ ∝ |v || |). Fokker-Planck simulation of Ohmic reversed field pinch (RFP) discharges in the MST device reveals transport velocity dependence stronger than |v || |) will give agreement with current and soft X-ray spectra in standard discharges, but in the higher confinement, current profile controlled PPCD discharges, transport is again electrostatic-like. This is consistent with the object of PPCD, which is to replace magnetic turbulence driven current with auxiliary CD to improve transport. The tokamak and high-confinement RFP results mutually reinforce the constant-in-velocity-space 'electrostatic-type turbulence' conclusion. The steady-state energy and toroidal current are governed by the same radial transport equation. (authors)

  14. RADIAL TRANSPORT EFFECTS ON ECCD IN THE TCV AND DIII-D TOKAMAKS AND ON OHMIC DISCHARGES IN THE MST RFP

    International Nuclear Information System (INIS)

    HARVEY, R.W.; SAUTER, O.; PRATER, R.; NIKKOLA, P.; O'CONNELL, R.; FOREST, C.B.

    2002-01-01

    The comprehensive CQL3D Fokker-Planck/Quasilinear simulation code has been benchmarked against experiment over a wide range of electron cyclotron conditions in the DIII-D tokamak (C.C. Petty et al., 14th Topical Conf. on RF Power in Plasmas, 2002). The same code, in disagreement with experiment, gives 560 kA of ECCD for a well documented, completely ECCD-driven, 100 kA TCV shot [O. Sauter et al, PRL, 2000]. Recent work (R.W. Harvey et al, Phys. Rev. Lett., 2002) has resolved the differences as due to radial transport at a level closely consistent with ITER scaling. Transport does not substantially affect DIII-D ECCD, but at similar ECH power has an overwhelming effect on the much smaller TCV. The transport is consistent with electrostatic-type diffusion (D ρρ constant in velocity-space) and not with a magnetic-type diffusion (D ρρ ∝ |v(parallel)|). Fokker-Planck simulation of Ohmic reversed field pinch (RFP) discharges in the MST device reveals transport velocity dependence stronger than |v(parallel)| will give agreement with current and soft X-ray spectra in standard discharges, but in the higher confinement, current profile controlled PPCD discharges, transport is again electrostatic-like. This is consistent with the object of PPCD, which is to replace magnetic turbulence driven current with auxiliary CD to improve transport. The tokamak and high-confinement RFP results mutually reinforce the constant-in-velocity-space ''electrostatic-type turbulence'' conclusion. The steady-state energy and toroidal current are governed by the same radial transport equation

  15. Ares I Integrated Test Approach

    Science.gov (United States)

    Taylor, Jim

    2008-01-01

    This slide presentation reviews the testing approach that NASA is developing for the Ares I launch vehicle. NASA is planning a complete series of development, qualification and verification tests. These include: (1) Upper stage engine sea-level and altitude testing (2) First stage development and qualification motors (3) Upper stage structural and thermal development and qualification test articles (4) Main Propulsion Test Article (MPTA) (5) Upper stage green run testing (6) Integrated Vehicle Ground Vibration Testing (IVGVT) and (7) Aerodynamic characterization testing.

  16. Wafer-level testing and test during burn-in for integrated circuits

    CERN Document Server

    Bahukudumbi, Sudarshan

    2010-01-01

    Wafer-level testing refers to a critical process of subjecting integrated circuits and semiconductor devices to electrical testing while they are still in wafer form. Burn-in is a temperature/bias reliability stress test used in detecting and screening out potential early life device failures. This hands-on resource provides a comprehensive analysis of these methods, showing how wafer-level testing during burn-in (WLTBI) helps lower product cost in semiconductor manufacturing.Engineers learn how to implement the testing of integrated circuits at the wafer-level under various resource constrain

  17. Operational test report, integrated system test (ventilation upgrade)

    International Nuclear Information System (INIS)

    HARTY, W.M.

    1999-01-01

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, AY102, AZ101, AZ102

  18. Operational test report integrated system test (ventilation upgrade)

    Energy Technology Data Exchange (ETDEWEB)

    HARTY, W.M.

    1999-10-05

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

  19. Passive BWR integral LOCA testing at the Karlstein test facility INKA

    Energy Technology Data Exchange (ETDEWEB)

    Drescher, Robert [AREVA GmbH, Erlangen (Germany); Wagner, Thomas [AREVA GmbH, Karlstein am Main (Germany); Leyer, Stephan [TH University of Applied Sciences, Deggendorf (Germany)

    2014-05-15

    KERENA is an innovative AREVA GmbH boiling water reactor (BWR) with passive safety systems (Generation III+). In order to verify the functionality of the reactor design an experimental validation program was executed. Therefore the INKA (Integral Teststand Karlstein) test facility was designed and erected. It is a mockup of the BWR containment, with integrated pressure suppression system. While the scaling of the passive components and the levels match the original values, the volume scaling of the containment compartments is approximately 1:24. The storage capacity of the test facility pressure vessel corresponds to approximately 1/6 of the KERENA RPV and is supplied by a benson boiler with a thermal power of 22 MW. In March 2013 the first integral test - Main Steam Line Break (MSLB) - was executed. The test measured the combined response of the passive safety systems to the postulated initiating event. The main goal was to demonstrate the ability of the passive systems to ensure core coverage, decay heat removal and to maintain the containment within defined limits. The results of the test showed that the passive safety systems are capable to bring the plant to stable conditions meeting all required safety targets with sufficient margins. Therefore the test verified the function of those components and the interplay between them. The test proved that INKA is an unique test facility, capable to perform integral tests of passive safety concepts under plant-like conditions. (orig.)

  20. Multisignal detecting system of pile integrity testing

    Science.gov (United States)

    Liu, Zuting; Luo, Ying; Yu, Shihai

    2002-05-01

    The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.

  1. Multiloop integral system test (MIST)

    International Nuclear Information System (INIS)

    Gloudemans, J.R.

    1989-07-01

    The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock and Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility -- the once-through integral system (OTIS) -- was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The individual tests are described in detail in Volumes 2 through 8 and Volume 11, and are summarized in Volume 1. Inter-group comparisons are addressed in this document, Volume 9. These comparisons are grouped as follows: mapping versus SBLOCA transients, SBLOCA, pump effects, and the effects of noncondensible gases. Appendix A provides an index and description of the microfiched plots for each test, which are enclosed with the corresponding Volumes 2 through 8. 147 figs., 5 tabs

  2. The Integral Test Facility Karlstein

    Directory of Open Access Journals (Sweden)

    Stephan Leyer

    2012-01-01

    Full Text Available The Integral Test Facility Karlstein (INKA test facility was designed and erected to test the performance of the passive safety systems of KERENA, the new AREVA Boiling Water Reactor design. The experimental program included single component/system tests of the Emergency Condenser, the Containment Cooling Condenser and the Passive Core Flooding System. Integral system tests, including also the Passive Pressure Pulse Transmitter, will be performed to simulate transients and Loss of Coolant Accident scenarios at the test facility. The INKA test facility represents the KERENA Containment with a volume scaling of 1 : 24. Component heights and levels are in full scale. The reactor pressure vessel is simulated by the accumulator vessel of the large valve test facility of Karlstein—a vessel with a design pressure of 11 MPa and a storage capacity of 125 m3. The vessel is fed by a benson boiler with a maximum power supply of 22 MW. The INKA multi compartment pressure suppression Containment meets the requirements of modern and existing BWR designs. As a result of the large power supply at the facility, INKA is capable of simulating various accident scenarios, including a full train of passive systems, starting with the initiating event—for example pipe rupture.

  3. Operational test report for LERF Basin 242AL-44 integrity test

    International Nuclear Information System (INIS)

    Galioto, T.M.

    1994-01-01

    This operational test report documents the results of LERF operational testing per operational test procedure (OTP) TFPE-WP-0231, ''LERF Basin Integrity Testing.'' The primary purpose of the OTP was to resolve test exceptions generated as a result of TFPE-WP-0184. The TOP was prepared and performed in accordance with WHC-SD-534-OTP-002, ''Operational Test Plan for the 242-A Evaporator Upgrades and the Liquid Effluent Retention Facility.'' WHC-S-086, ''Specification for Operational Testing of the Liquid Effluent Retention Facility, Basin Integrity Testing,'' identified the test requirements and acceptance criteria. The completed, signed-off test procedure is contained in Appendix A. The test log is contained in Appendix B. Section 2.1 describes all the test exceptions written during performance of the Operational Test Procedure. The test revisions generated during the testing are discussed in Section 2.2. The dispositioned test exception forms are contained in Appendix C

  4. Addressable-Matrix Integrated-Circuit Test Structure

    Science.gov (United States)

    Sayah, Hoshyar R.; Buehler, Martin G.

    1991-01-01

    Method of quality control based on use of row- and column-addressable test structure speeds collection of data on widths of resistor lines and coverage of steps in integrated circuits. By use of straightforward mathematical model, line widths and step coverages deduced from measurements of electrical resistances in each of various combinations of lines, steps, and bridges addressable in test structure. Intended for use in evaluating processes and equipment used in manufacture of application-specific integrated circuits.

  5. Integrated test plan for directional boring

    International Nuclear Information System (INIS)

    Volk, B.W.

    1993-01-01

    This integrated test plan describes the field testing of the DITCH WITCH Directional Boring System. DITCH WITCH is a registered trademark of The Charles Machine Works, Inc., Perry, Oklahoma. The test is being conducted as a coordinated effort between Charles Machine Works (CMW), Sandia National Laboratories (SNL), and the Westinghouse Hanford Company (WHC). Funding for the WHC portion of the project is through the Volatile Organic Compound-Arid Integrated Demonstration (VOC-Arid ID). The purpose of the test is to evaluate the performance of the directional boring system for possible future use on environmental restoration projects at Hanford and other Department of Energy (DOE) sites. The test will be conducted near the 200 Areas Fire Station located between the 200 East and 200 West Area of the Hanford Site. The directional boring system will be used to drill and complete (with fiberglass casing) two horizontal boreholes. A third borehole will be drilled to test sampling equipment but will not be completed with casing

  6. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  7. Overview of containment integrity test at NUPEC

    International Nuclear Information System (INIS)

    Takumi, K.; Yamada, T.

    2004-01-01

    NUPEC has started NUPEC Containment Integrity project entitled 'Proving Test on the Reliability for Reactor Containment Vessel' since June 1987. This is the project for the term of twelve years sponsored by MITI (Ministry of International Trade and Industry, Japanese Government). The test items are (1) Hydrogen mixing and distribution test, (2) Hydrogen Burning Test, (3) Iodine trapping characteristics test, and (4) Structural behavior test. Based on the test results, computer codes are verified and as the results of analysis and evaluation by the computer codes, containment integrity is to be confirmed. This paper indicates the results of hydrogen mixing and distribution test and hydrogen burning test. The NUPEC tests conducted so far suggest that hydrogen will be well mixed in the model containment vessel and the prediction by the computer code is in excellent agreement with the data. The NUPEC hydrogen burning test data is in good agreement with the FITS data at SNL that were obtained at the lower hydrogen concentration condition. (author)

  8. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  9. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Baek, W. P.; Song, C. H.; Kim, Y. S. and others

    2005-02-15

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform various integral effect tests for design, operation, and safety regulation of pressurized water reactors. During the first phase of this project (1997.8{approx}2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished: a full-height, 1/300-volume-scaled full pressure facility for APR1400, an evolutionary pressurized water reactor that was developed by Korean industry. Main objectives of the present phase (2002.4{approx}2005.2), was to optimize the facility design and to construct the experimental facility. We have performed following researches: 1) Optimization of the basic design of the thermal-hydraulic integral effect test facility for PWRs - ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) - Reduced height design for APR1400 (+ specific design features of KSNP safety injection systems) - Thermal-hydraulic scaling based on three-level scaling methodology by Ishii et al. 2) Construction of the ATLAS facility - Detailed design of the test facility - Manufacturing and procurement of components - Installation of the facility 3) Development of supporting technology for integral effect tests - Development and application of advanced instrumentation technology - Preliminary analysis of test scenarios - Development of experimental procedures - Establishment and implementation of QA system/procedure.

  10. Test Structures For Bumpy Integrated Circuits

    Science.gov (United States)

    Buehler, Martin G.; Sayah, Hoshyar R.

    1989-01-01

    Cross-bridge resistors added to comb and serpentine patterns. Improved combination of test structures built into integrated circuit used to evaluate design rules, fabrication processes, and quality of interconnections. Consist of meshing serpentines and combs, and cross bridge. Structures used to make electrical measurements revealing defects in design or fabrication. Combination of test structures includes three comb arrays, two serpentine arrays, and cross bridge. Made of aluminum or polycrystalline silicon, depending on material in integrated-circuit layers evaluated. Aluminum combs and serpentine arrays deposited over steps made by polycrystalline silicon and diffusion layers, while polycrystalline silicon versions of these structures used to cross over steps made by thick oxide layer.

  11. UAS-NAS Integrated Human in the Loop: Test Environment Report

    Science.gov (United States)

    Murphy, Jim; Otto, Neil; Jovic, Srba

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research was broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of the Test Infrastructure theme was to enable development and validation of airspace integration procedures and performance standards, including the execution of integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project developed an adaptable, scalable, and schedulable relevant test environment incorporating live, virtual, and constructive elements capable of validating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project planned to conduct three integrated events: a Human-in-the-Loop simulation and two Flight Test series that integrated key concepts, technologies and/or procedures in a relevant air traffic environment. Each of

  12. Optimal integration and test plans for software releases of lithographic systems

    NARCIS (Netherlands)

    Boumen, R.; Jong, de I.S.M.; Mortel - Fronczak, van de J.M.; Rooda, J.E.

    2007-01-01

    This paper describes a method to determine the optimal integration and test plan for embedded systems software releases. The method consists of four steps: 1)describe the integration and test problem in an integration and test model which is introduced in this paper, 2) determine possible test

  13. Best Practices: Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davis, Lydia

    2018-01-01

    This presentation discusses Best Practices for Power Quality and Integrated Testing at JSC in regards to electrical systems. These high-level charts include mostly generic information; however, a specific issue is discussed involving flight hardware that could have been discovered prior to flight with an integrated test.

  14. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  15. Aviation Systems Test and Integration Lab (AvSTIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aviation Systems Test and Integration Laboratory offers an innovative approach to aviation system and subsystem testing by fully immersing aviation platforms in...

  16. The Predominance Of Integrative Tests Over Discrete Point Tests In Evaluating The Medical Students' General English Knowledge

    Directory of Open Access Journals (Sweden)

    maryam Heydarpour Meymeh

    2009-03-01

    Full Text Available Background and purpose: Multiple choice tests are the most common type of tests used in evaluating the general English knowledge of the students in most medical universities, however the efficacy of these tests are not examined precisely. Wecompare and examine the integrative tests and discrete point tests as measures of the English language knowledge of medical students.Methods: Three tests were given to 60 undergraduate physiotherapy and Audiology students in their second year of study (after passing their general English course. They were divided into 2 groups.The first test for both groups was an integrative test, writing. The second test was a multiple - choice test 0.(prepositions for group one and a multiple - choice test of tensesfor group two. The same items which were mostfi-equently used wrongly in thefirst test were used in the items of the second test. A third test, a TOEFL, was given to the subjects in order to estimate the correlation between this test and tests one and two.Results: The students performed better in the second test, discrete point test rather than the first which was an integrative test. The same grammatical mistakes in the composition were used correctly in the multiple choice tests by the students.Conclusion:Our findings show that student perform better in non-productive rather than productive test. Since being competent English language user is an expected outcome of university language courses it seems warranted to switch to integrative tests as a measure of English language competency.Keywords: INTEGRATIVE TESTS, ENGLISH LANGUAGE FOR MEDICINE, ACADEMIC ENGLISH

  17. Test requirements for the integral effect test to simulate Korean PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chul Hwa; Park, C. K.; Lee, S. J.; Kwon, T. S.; Yun, B. J.; Chung, M. K

    2001-02-01

    In this report, the test requirements are described for the design of the integral effect test facility to simulate Korean PWR plants. Since the integral effect test facility should be designed so as to simulate various thermal hydraulic phenomena, as closely as possible, to be occurred in real plants during operation or anticipated transients, the design and operational characteristics of the reference plants (Korean Standard Nuclear Plant and Korean Next Generation Reactor)were analyzed in order to draw major components, systems, and functions to be satisfied or simulated in the test facility. The test matrix is set up by considering major safety concerns of interest and the test objectives to confirm and enhance the safety of the plants. And the analysis and prioritization of the test matrix leads to the general design requirements of the test facility. Based on the general design requirements, the design criteria is set up for the basic and detailed design of the test facility. And finally it is drawn the design requirements specific to the fluid system and measurement system of the test facility. The test requirements in this report will be used as a guideline to the scaling analysis and basic design of the test facility. The test matrix specified in this report can be modified in the stage of main testing by considering the needs of experiments and circumstances at that time.

  18. Test requirements for the integral effect test to simulate Korean PWR plants

    International Nuclear Information System (INIS)

    Song, Chul Hwa; Park, C. K.; Lee, S. J.; Kwon, T. S.; Yun, B. J.; Chung, M. K.

    2001-02-01

    In this report, the test requirements are described for the design of the integral effect test facility to simulate Korean PWR plants. Since the integral effect test facility should be designed so as to simulate various thermal hydraulic phenomena, as closely as possible, to be occurred in real plants during operation or anticipated transients, the design and operational characteristics of the reference plants (Korean Standard Nuclear Plant and Korean Next Generation Reactor)were analyzed in order to draw major components, systems, and functions to be satisfied or simulated in the test facility. The test matrix is set up by considering major safety concerns of interest and the test objectives to confirm and enhance the safety of the plants. And the analysis and prioritization of the test matrix leads to the general design requirements of the test facility. Based on the general design requirements, the design criteria is set up for the basic and detailed design of the test facility. And finally it is drawn the design requirements specific to the fluid system and measurement system of the test facility. The test requirements in this report will be used as a guideline to the scaling analysis and basic design of the test facility. The test matrix specified in this report can be modified in the stage of main testing by considering the needs of experiments and circumstances at that time

  19. Task force for integral test of High Energy nuclear data

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    According to completion of the JENDL-High Energy file for neutron nuclear cross sections up to 50 MeV, a task force for integral test of high energy nuclear data was organized to discuss a guide line for integral test activities. A status of existing differential and integral experiments and how to perform such a test were discussed in the task force. Here the purpose and outline of the task force is explained with some future problems raised in discussion among the task member. (author)

  20. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  1. The NIRspec assembly integration and test status

    Science.gov (United States)

    Wettemann, Thomas; Ehrenwinkler, Ralf; Johnson, Thomas E.; Maschmann, Marc; Mosner, Peter; te Plate, Maurice; Rödel, Andreas

    2017-11-01

    The Near-Infrared Spectrograph (NIRSpec) is one of the four instruments on the James Webb Space Telescope (JWST) scheduled for launch in 2018. NIRSpec has been manufactured and tested by an European industrial consortium led by Airbus Defence and Space and delivered to the European Space Agency (ESA) and NASA in September 2013. Since then it has successfully been integrated into the JWST Integrated Science Instrument Module (ISIM) and is currently in ISIM Cryo-Vacuum Test#2. Since however two of its most important assemblies, the Focal Plane Assembly (FPA) and the Micro-Shutter Assembly (MSA) need to be replaced by new units we will present the status of the instrument, the status of its new flight assemblies in manufacturing and testing and give an outlook on the planned exchange activities and the following instrument re-verification.

  2. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  3. Integrated Test and Evaluation (ITE) Flight Test Series 4

    Science.gov (United States)

    Marston, Michael

    2016-01-01

    The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

  4. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    International Nuclear Information System (INIS)

    Baek, Won Pil; Song, C. H.; Kim, Y. S.

    2007-02-01

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform the tests for design, operation, and safety regulation of pressurized water reactors. In the first phase of this project (1997.8∼2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished. In the second phase (2002.4∼2005.2), an optimized design of the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) was established and the construction of the facility was almost completed. In the third phase (2005.3∼2007.2), the construction and commission tests of the ATLAS are to be completed and some first-phase tests are to be conducted

  5. Testing can counteract proactive interference by integrating competing information

    Science.gov (United States)

    Wahlheim, Christopher N.

    2015-01-01

    Testing initially learned information before presenting new information has been shown to counteract the deleterious effects of proactive interference by segregating competing sources of information. The present experiments were conducted to demonstrate that testing can also have its effects in part by integrating competing information. Variations of classic A–B, A–D paired-associate learning paradigms were employed that included two lists of word pairs and a cued-recall test. Repeated pairs appeared in both lists (A–B, A–B), control pairs appeared in List 2 only (A–B, C–D), and changed pairs appeared with the same cue in both lists but with different responses (A–B, A–D). The critical manipulation was whether pairs were tested or restudied in an interpolated phase that occurred between Lists 1 and 2. On a final cued-recall test, participants recalled List 2 responses and then indicated when they recollected that responses had earlier changed between lists. The change recollection measure indexed the extent to which competing responses were integrated during List 2. Change was recollected more often for tested than for restudied pairs. Proactive facilitation was obtained in cued recall when change was recollected, whereas proactive interference was obtained when change was not recollected. These results provide evidence that testing counteracted proactive interference in part by making List 1 responses more accessible during List 2, thus promoting integration and increasing later recollection of change. These results have theoretical implications because they show that testing can counteract proactive interference by integrating or segregating competing information. PMID:25120241

  6. Testing can counteract proactive interference by integrating competing information.

    Science.gov (United States)

    Wahlheim, Christopher N

    2015-01-01

    Testing initially learned information before presenting new information has been shown to counteract the deleterious effects of proactive interference by segregating competing sources of information. The present experiments were conducted to demonstrate that testing can also have its effects in part by integrating competing information. Variations of classic A-B, A-D paired-associate learning paradigms were employed that included two lists of word pairs and a cued-recall test. Repeated pairs appeared in both lists (A-B, A-B), control pairs appeared in List 2 only (A-B, C-D), and changed pairs appeared with the same cue in both lists but with different responses (A-B, A-D). The critical manipulation was whether pairs were tested or restudied in an interpolated phase that occurred between Lists 1 and 2. On a final cued-recall test, participants recalled List 2 responses and then indicated when they recollected that responses had earlier changed between lists. The change recollection measure indexed the extent to which competing responses were integrated during List 2. Change was recollected more often for tested than for restudied pairs. Proactive facilitation was obtained in cued recall when change was recollected, whereas proactive interference was obtained when change was not recollected. These results provide evidence that testing counteracted proactive interference in part by making List 1 responses more accessible during List 2, thus promoting integration and increasing later recollection of change. These results have theoretical implications because they show that testing can counteract proactive interference by integrating or segregating competing information.

  7. Application of advanced non-destructive testing for testing the integrity of concrete foundations

    International Nuclear Information System (INIS)

    Nguyen Le Son; Nguyen Phuoc Lan; Pham The Hung; Vu Huy Thuc

    2004-01-01

    Solid foundations are integral important part of any structures. Obtaining accurate and timely information on the integrity of structural foundations is essential for project progress and success. Cross-hole sonic method has been widely accepted for quality assurance and quality control on projects with deep foundations, and to assess the integrity of other civil engineering structures. Under the framework of the basic VAEC project (2003) and project VIE/8/013, the Cross-hole sonic method (CHM) was evaluated at Center for Nuclear Techniques, Hochiminh City (CNT). Background information on principle and general description of the method as is typically applied in the evaluation of deep foundations are also summarized. A suitable experimental model of the shaft foundations was prepared, where the artificial defects can be controlled for the Cross-hole sonic logging was conducted by measuring the propagation time of ultrasonic signals between two probes in vertical holes in a shaft. The purpose of the test program is to evaluate the ability of the cross-hole sonic method to identify the defects present in the experimental model, to evaluate the capabilities of the method and the equipped system Cs-97, to improve the presentation of test results to meet requirements for interpreting the quality of drilled shafts by processing the data of Cs-97. The cross-hole sonic testing program is describe. Summarizes the results and analysis of the cross-hole sonic logging are presented to highlight both the applicability and limitations of the method. The cross-hole sonic logging evaluation is a valuable non-destructive method in assessing the integrity of deep foundations. The cross-hole sonic logging tests successfully determined the location and extent of the built-in defects on experimental model shaft. Minimum sizes of defects can be detected were about ≥ 10 cm Cs-97. Effects of the directions, detectable sizes and natures of defects were studied. The apparent velocities

  8. Integrated Vehicle Ground Vibration Testing of Manned Spacecraft: Historical Precedent

    Science.gov (United States)

    Lemke, Paul R.; Tuma, Margaret L.; Askins, Bruce R.

    2008-01-01

    For the first time in nearly 30 years, NASA is developing a new manned space flight launch system. The Ares I will carry crew and cargo to not only the International Space Station, but onward for the future exploration of the Moon and Mars. The Ares I control system and structural designs use complex computer models for their development. An Integrated Vehicle Ground Vibration Test (IVGVT) will validate the efficacy of these computer models. The IVGVT will reduce the technical risk of unexpected conditions that could place the vehicle or crew in jeopardy. The Ares Project Office's Flight and Integrated Test Office commissioned a study to determine how historical programs, such as Saturn and Space Shuttle, validated the structural dynamics of an integrated flight vehicle. The study methodology was to examine the historical record and seek out members of the engineering community who recall the development of historic manned launch vehicles. These records and interviews provided insight into the best practices and lessons learned from these historic development programs. The information that was gathered allowed the creation of timelines of the historic development programs. The timelines trace the programs from the development of test articles through test preparation, test operations, and test data reduction efforts. These timelines also demonstrate how the historical tests fit within their overall vehicle development programs. Finally, the study was able to quantify approximate staffing levels during historic development programs. Using this study, the Flight and Integrated Test Office was able to evaluate the Ares I Integrated Vehicle Ground Vibration Test schedule and workforce budgets in light of the historical precedents to determine if the test had schedule or cost risks associated with it.

  9. Major Achievements and Prospect of the ATLAS Integral Effect Tests

    International Nuclear Information System (INIS)

    Choi, K.; Kim, Y.; Song, C.; Baek, W.

    2012-01-01

    A large-scale thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been operated by KAERI. The reference plant of ATLAS is the APR1400 (Advanced Power Reactor, 1400 MWe). Since 2007, an extensive series of experimental works were successfully carried out, including large break loss of coolant accident tests, small break loss of coolant accident tests at various break locations, steam generator tube rupture tests, feed line break tests, and steam line break tests. These tests contributed toward an understanding of the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing validation data for evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Major discoveries and lessons found in the past integral effect tests are summarized in this paper. As the demand for integral effect tests is on the rise due to the active national nuclear R and D program in Korea, the future prospects of the application of the ATLAS facility are also discussed.

  10. Economic testing of large integrated switching circuits - a challenge to the test engineer

    International Nuclear Information System (INIS)

    Kreinberg, W.

    1978-01-01

    With reference to large integrated switching circuits, one can use an incoming standard programme test or the customer's switching circuits. The author describes the development of suitable, extensive and economical test programmes. (orig.) [de

  11. Minimizing time for test in integrated circuit

    OpenAIRE

    Andonova, A. S.; Dimitrov, D. G.; Atanasova, N. G.

    2004-01-01

    The cost for testing integrated circuits represents a growing percentage of the total cost for their production. The former strictly depends on the length of the test session, and its reduction has been the target of many efforts in the past. This paper proposes a new method for reducing the test length by adopting a new architecture and exploiting an evolutionary optimisation algorithm. A prototype of the proposed approach was tested on 1SCAS standard benchmarks and theexperimental results s...

  12. CopperCore Service Integration, Integrating IMS Learning Design and IMS Question and Test Interoperability

    NARCIS (Netherlands)

    Vogten, Hubert; Martens, Harrie; Nadolski, Rob; Tattersall, Colin; Van Rosmalen, Peter; Koper, Rob

    2006-01-01

    Vogten, H., Martens, H., Nadolski, R., Tattersall, C., Rosmalen, van, P., Koper, R., (2006). CopperCore Service Integration, Integrating IMS Learning Design and IMS Question and Test Interoperability. Proceedings of the 6th IEEE International Conference on Advanced Learning Technologies (pp.

  13. Power, Avionics and Software - Phase 1.0:. [Subsystem Integration Test Report

    Science.gov (United States)

    Ivancic, William D.; Sands, Obed S.; Bakula, Casey J.; Oldham, Daniel R.; Wright, Ted; Bradish, Martin A.; Klebau, Joseph M.

    2014-01-01

    This report describes Power, Avionics and Software (PAS) 1.0 subsystem integration testing and test results that occurred in August and September of 2013. This report covers the capabilities of each PAS assembly to meet integration test objectives for non-safety critical, non-flight, non-human-rated hardware and software development. This test report is the outcome of the first integration of the PAS subsystem and is meant to provide data for subsequent designs, development and testing of the future PAS subsystems. The two main objectives were to assess the ability of the PAS assemblies to exchange messages and to perform audio testing of both inbound and outbound channels. This report describes each test performed, defines the test, the data, and provides conclusions and recommendations.

  14. Integration and test of the ATLAS Semiconductor Tracker

    CERN Document Server

    Pernegger, H

    2007-01-01

    The ATLAS Semiconductor Tracker (SCT) will be a central part of the tracking system of the ATLAS experiment and is one of the major new silicon detector systems for LHC. The paper summarizes the system integration of the SCT from individual components to the completed tracker barrel and endcaps ready for installation in the pit. Particular attention will be given to the test results obtained during the different integration steps: from single barrels and disks to the final tests inside the ID before installation in the pit. The tests provided us with operational experience for a significant fraction of the full detector system and showed the very good performance of the final assembled detector.

  15. SOCIAL INTEGRATION: TESTING ANTECEDENTS OF TIME SPENT ONLINE

    Directory of Open Access Journals (Sweden)

    Lily Suriani Mohd Arif

    2013-07-01

    Full Text Available The literature on the relationship of social integration and time spent onlineprovides conflicting evidence of the relationship of social integration with timespent online. The study identifies and highlightsthe controversy and attempts toclarify the relationship of social integration withtime spent online bydecomposing the construct social integration into its affective and behavioraldimensions . Thestudy tests antecedents and effects of time spent online in arandom sample of senior level undergraduate students at a public university inMalaysia. The findings indicated that while self-report measures of behavioralsocial integration did not predict time spent online, and, the affective socialintegration had an inverse relationship with time spent online.

  16. Testing integrated sensors for cooperative remote monitoring

    International Nuclear Information System (INIS)

    Filby, E.E.; Smith, T.E.; Albano, R.K.; Andersen, M.K.; Lucero, R.L.; Tolk, K.M.; Andrews, N.S.

    1996-01-01

    The Modular Integrated Monitoring System (MIMS) program, with Sandia National Laboratory (SNL) as the lead lab, was devised to furnish sensors and integrated multi-sensor systems for cooperative remote monitoring. The Idaho National Engineering Laboratory (INEL), via the Center for Integrated Monitoring and Control (CIMC), provides realistic field tests of the sensors and sensor-integration approach for the MIMS, and for other similar programs. This has two important goals: it helps insure that these systems are truly read for use, and provides a platform so they can be demonstrated for potential users. A remote monitoring test/demonstration has been initiated at the Idaho Chemical Processing Plant (ICPP) to track the movement of spent nuclear fuel from one storage location to another, using a straddle carrier and shielded cask combination. Radiation monitors, motion sensors, videocameras, and other devices from several US Department of Energy (DOE) labs and commercial vendors were linked on the network. Currently, project personnel are collecting raw data from this large array of sensors, without trying to program any special network activities or other responses. These data will be used to determine which devices can actually provide useful information for a cooperative monitoring situation, versus those that may be redundant

  17. MANPRINT Handbook for RFP Development

    Science.gov (United States)

    1990-06-01

    a way as to provide ease of movement and transportation (i.e., on a wheeled stand, or with integral casters ). C.4.8 MANPRINT Program. C.4.8.1...constructed. Th6 propos,-, -Huma,. Elgi-ee"rin- "ro( . specify mockups requiring procuring activity approval and modification to -reflect changes. The... modifications to the regulations the Government is evoking. Specifically, the DSL will: (a) Identify by number, revision, title and issuance date all directly

  18. Topical Knowledge in L2 Speaking Assessment: Comparing Independent and Integrated Speaking Test Tasks

    Science.gov (United States)

    Huang, Heng-Tsung Danny; Hung, Shao-Ting Alan; Plakans, Lia

    2018-01-01

    Integrated speaking test tasks (integrated tasks) provide reading and/or listening input to serve as the basis for test-takers to formulate their oral responses. This study examined the influence of topical knowledge on integrated speaking test performance and compared independent speaking test performance and integrated speaking test performance…

  19. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel cell research and development projects through in-situ fuel cell testing. Photo of a researcher running

  20. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  1. Integrated Virtual Environment Test Concepts and Objectives

    National Research Council Canada - National Science Library

    Tackett, Gregory

    2001-01-01

    ...), a series of integration and verification tests were conducted to provide development milestones for the simulation architecture and tools that would be needed for the full-up live/virtual field experiment...

  2. Melcor benchmarking against integral severe fuel damage tests

    Energy Technology Data Exchange (ETDEWEB)

    Madni, I.K. [Brookhaven National Lab., Upton, NY (United States)

    1995-09-01

    MELCOR is a fully integrated computer code that models all phases of the progression of severe accidents in light water reactor nuclear power plants, and is being developed for the U.S. Nuclear Regulatory Commission (NRC) by Sandia National Laboratories (SNL). Brookhaven National Laboratory (BNL) has a program with the NRC to provide independent assessment of MELCOR, and a very important part of this program is to benchmark MELCOR against experimental data from integral severe fuel damage tests and predictions of that data from more mechanistic codes such as SCDAP or SCDAP/RELAP5. Benchmarking analyses with MELCOR have been carried out at BNL for five integral severe fuel damage tests, namely, PBF SFD 1-1, SFD 14, and NRU FLHT-2, analyses, and their role in identifying areas of modeling strengths and weaknesses in MELCOR.

  3. Sensor integration and testing in an airborne environment

    Science.gov (United States)

    Ricks, Timothy P.; Streling, Julie T.; Williams, Kirk W.

    2005-11-01

    The U.S. Army Redstone Technical Test Center (RTTC) has been supporting captive flight testing of missile sensors and seekers since the 1980's. Successful integration and test of sensors in an airborne environment requires attention to a broad range of disciplines. Data collection requirements drive instrumentation and flight profile configurations, which along with cost and airframe performance factors influence the choice of test aircraft. Installation methods used for instrumentation must take into consideration environmental and airworthiness factors. In addition, integration of test equipment into the aircraft will require an airworthiness release; procedures vary between the government for military aircraft, and the Federal Aviation Administration (FAA) for the use of private, commercial, or experimental aircraft. Sensor mounting methods will depend on the type of sensor being used, both for sensor performance and crew safety concerns. Pilots will require navigation input to permit the execution of accurate and repeatable flight profiles. Some tests may require profiles that are not supported by standard navigation displays, requiring the use of custom hardware/software. Test locations must also be considered in their effect on successful data collection. Restricted airspace may also be required, depending on sensor emissions and flight profiles.

  4. Dynamic behavior and functional integrity tests on RC shear walls

    International Nuclear Information System (INIS)

    Akino, Kinji; Nasuda, Toshiaki; Shibata, Akenori.

    1991-01-01

    A project consisting of seven subprojects has been conducted to study the dynamic behavior and functional integrity of reinforced concrete (RC) shear walls in reactor buildings. The objective of this project is to obtain the data to improve and prepare the seismic analysis code regarding the nonlinear structural behavior and integrity of reactor buildings during and after earthquakes. The project started in April, 1986, and will end in March, 1994. Seven subprojects are strain rate test, damping characteristic test, ultimate state response test and the verification test for the test of restoring force characteristics regarding dynamic restoring force characteristics and damping performance; the restoring force characteristic test on the shear walls with openings; and pull-out strength test and the test on air leakage through concrete cracks regarding the functional integrity. The objectives of respective subprojects, the test models and the interim results are reported. Three subprojects have been completed by March, 1990. The results of these projects will be used for the overall evaluation. The strain rate test showed that the ultimate strength of shear walls increased with strain rate. A formula for estimating air flow through the cracks in walls was given by the leakage test. (K.I.)

  5. Testing Fixture For Microwave Integrated Circuits

    Science.gov (United States)

    Romanofsky, Robert; Shalkhauser, Kurt

    1989-01-01

    Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

  6. Integrating IMS Learning Design and IMS Question and Test Interoperability using CopperCore Service Integration

    NARCIS (Netherlands)

    Vogten, Hubert; Martens, Harrie; Nadolski, Rob; Tattersall, Colin; Van Rosmalen, Peter; Koper, Rob

    2006-01-01

    Please, cite this publication as: Vogten, H., Martens, H., Nadolski, R., Tattersall, C., van Rosmalen, P., & Koper, R. (2006). Integrating IMS Learning Design and IMS Question and Test Interoperability using CopperCore Service Integration. Proceedings of International Workshop in Learning Networks

  7. An integral effect test facility of the SMART, SMART ITL

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; Moon, Sang Ki; Kim, Yeon Sik; Cho, Seok; Choi, Ki Yong; Bae, Hwang; Kim, Dong Eok; Choi, Nam Hyun; Min, Kyoung Ho; Ko, Yung Joo; Shin, Yong Cheol; Park, Rae Joon; Lee, Won Jae; Song, Chul Hwa; Yi, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    SMART (System integrated Modular Advanced ReacTor) is a 330 MWth integral pressurized water reactor (iPWR) developed by KAERI and had obtained standard design approval (SDA) from Korean regulatory authority on July 2012. In this SMART design main components including a pressurizer, reactor coolant pumps and steam generators are installed in a reactor pressure vessel without any large connecting pipes. As the LBLOCA scenario is inherently excluded, its safety systems could be simplified only to ensure the safety during the SBLOCA scenarios and the other system transients. An integral effect test loop for the SMART (SMART ITL), or called as FESTA, had been designed to simulate the integral thermal hydraulic behavior of the SMART. The objectives of the SMART ITL are to investigate and understand the integral performance of reactor systems and components and the thermal hydraulic phenomena occurred in the system during normal, abnormal and emergency conditions, and to verify the system safety during various design basis events of the SMART. The integral effect test data will also be used to validate the related thermal hydraulic models of the safety analysis code such as TASS/SMR S, which is used for performance and accident analysis of the SMART design. This paper introduces the scaling analysis and scientific design of the integral test facility of the SMART, SMART ITL and its scaling analysis results.

  8. Preparation and Integration of ALHAT Precision Landing Technology for Morpheus Flight Testing

    Science.gov (United States)

    Carson, John M., III; Robertson, Edward A.; Pierrottet, Diego F.; Roback, Vincent E.; Trawny, Nikolas; Devolites, Jennifer L.; Hart, Jeremy J.; Estes, Jay N.; Gaddis, Gregory S.

    2014-01-01

    The Autonomous precision Landing and Hazard Avoidance Technology (ALHAT) project has developed a suite of prototype sensors for enabling autonomous and safe precision land- ing of robotic or crewed vehicles on solid solar bodies under varying terrain lighting condi- tions. The sensors include a Lidar-based Hazard Detection System (HDS), a multipurpose Navigation Doppler Lidar (NDL), and a long-range Laser Altimeter (LAlt). Preparation for terrestrial ight testing of ALHAT onboard the Morpheus free- ying, rocket-propelled ight test vehicle has been in progress since 2012, with ight tests over a lunar-like ter- rain eld occurring in Spring 2014. Signi cant work e orts within both the ALHAT and Morpheus projects has been required in the preparation of the sensors, vehicle, and test facilities for interfacing, integrating and verifying overall system performance to ensure readiness for ight testing. The ALHAT sensors have undergone numerous stand-alone sensor tests, simulations, and calibrations, along with integrated-system tests in special- ized gantries, trucks, helicopters and xed-wing aircraft. A lunar-like terrain environment was constructed for ALHAT system testing during Morpheus ights, and vibration and thermal testing of the ALHAT sensors was performed based on Morpheus ights prior to ALHAT integration. High- delity simulations were implemented to gain insight into integrated ALHAT sensors and Morpheus GN&C system performance, and command and telemetry interfacing and functional testing was conducted once the ALHAT sensors and electronics were integrated onto Morpheus. This paper captures some of the details and lessons learned in the planning, preparation and integration of the individual ALHAT sen- sors, the vehicle, and the test environment that led up to the joint ight tests.

  9. Alternative containment integrity test methods, an overview of possible techniques

    International Nuclear Information System (INIS)

    Spletzer, B.L.

    1986-01-01

    A study is being conducted to develop and analyze alternative methods for testing of containment integrity. The study is focused on techniques for continuously monitoring containment integrity to provide rapid detection of existing leaks, thus providing greater certainty of the integrity of the containment at any time. The study is also intended to develop techniques applicable to the currently required Type A integrated leakage rate tests. A brief discussion of the range of alternative methods currently being considered is presented. The methods include applicability to all major containment types, operating and shutdown plant conditions, and quantitative and qualitative leakage measurements. The techniques are analyzed in accordance with the current state of knowledge of each method. The bulk of the techniques discussed are in the conceptual stage, have not been tested in actual plant conditions, and are presented here as a possible future direction for evaluating containment integrity. Of the methods considered, no single method provides optimum performance for all containment types. Several methods are limited in the types of containment for which they are applicable. The results of the study to date indicate that techniques for continuous monitoring of containment integrity exist for many plants and may be implemented at modest cost

  10. 2000 MCM electrical power jumper cable with controlled flexibility: Design and life cycle test

    International Nuclear Information System (INIS)

    Bultman, D.H.; Sims, J.R.; Reass, W.A.

    1989-01-01

    The ZTH Reversed Field Pinch (RFP) plasma confinement experiment being built at the Los Alamos National Laboratory will use magnet coils to provide ohmic heating currents in the plasma. The ohmic heating coils are supported by a structure that will allow them limited movement with respect to surrounding hardware and the connecting electrical bus work. To minimize displacement-induced stresses in the coils, ''flexible'' power conducting links are necessary to accommodate the relative motion between the bus work and the coils. A semi-flexible 2000 MCM jumper cable has been designed with enough flexibility to allow free movement of the coils, yet it is stiff enough to withstand large magnetically-induced lateral loads and minimize the effect of the lateral loads on the magnet coil leads. A full-power life cycle test of the jumper was performed under magnetic, thermal and dynamic loads that closely simulate the expected operating conditions. This test evaluated the structural and electrical integrity of the jumper as well as the quality and reliability of the bolted electrical connections at the jumper ends in a high-stress, cyclic-loading environment. The jumper cable design is presented with an explanation of the requirements for a semi-flexible link. A description of the life cycle test and test results are given, as well as a description of the test apparatus and setup. 4 figs

  11. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    2001-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of ± 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  12. Integration test of ITER full-scale vacuum vessel sector

    International Nuclear Information System (INIS)

    Nakahira, M.; Koizumi, K.; Oka, K.

    1999-01-01

    The full-scale Sector Model Project, which was initiated in 1995 as one of the Large Seven ITER R and D Projects, completed all R and D activities planned in the ITER-EDA period with the joint effort of the ITER Joint Central Team (JCT), the Japanese, the Russian Federation (RF) and the United States (US) Home Teams. The fabrication of a full-scale 18 toroidal sector, which is composed of two 9 sectors spliced at the port center, was successfully completed in September 1997 with the dimensional accuracy of - 3 mm for the total height and total width. Both sectors were shipped to the test site in JAERI and the integration test was begun in October 1997. The integration test involves the adjustment of field joints, automatic Narrow Gap Tungsten Inert Gas (NG-TIG) welding of field joints with splice plates, and inspection of the joint by ultrasonic testing (UT), which are required for the initial assembly of ITER vacuum vessel. This first demonstration of field joint welding and performance test on the mechanical characteristics were completed in May 1998 and the all results obtained have satisfied the ITER design. In addition to these tests, the integration with the mid plane port extension fabricated by the Russian Home Team, and the cutting and re-welding test of field joints by using full-remotized welding and cutting system developed by the US Home Team, are planned as post EDA activities. (author)

  13. Reversed-Field Pinch plasma model

    International Nuclear Information System (INIS)

    Miley, G.H.; Nebel, R.A.; Moses, R.W.

    1979-01-01

    The stability of a Reversed-Field Pinch (RFP) is strongly dependent on the plasma profile and the confining sheared magnetic field. Magnetic diffusion and thermal transport produce changing conditions of stability. Despite the limited understanding of RFP transport, modelling is important to predict general trends and to study possible field programming options. To study the ZT-40 experiment and to predict the performance of future RFP reactors, a one-dimensional transport code has been developed. This code includes a linear, ideal MHD stability check based on an energy principle. The transport section integrates plasma profiles forward in time while the stability section periodically checks the stability of the evolving plasma profile

  14. Glovebox characterization and barrier integrity testing using fluorescent powder

    International Nuclear Information System (INIS)

    Wahlquist, D.R.

    1996-01-01

    This paper presents a method for characterizing the spread of contamination and testing the barrier integrity of a new glovebox during material transfer operations and glove change-outs using fluorescent powder. Argonne National Laboratory-West has performed this test on several new gloveboxes prior to putting them into service. The test is performed after the glovebox has been leak tested and all systems have been verified to be operational. The purpose of the test is to show that bag-in/bag-out operations and glove change-outs can be accomplished without spreading the actual contaminated material to non-contaminated areas. The characterization test also provides information as to where contamination might be expected to build-up during actual operations. The fluorescent powder is used because it is easily detectable using an ultra-violet light and disperses in a similar fashion to radioactive material. The characterization and barrier integrity test of a glovebox using fluorescent powder provides a visual method of determining areas of potential contamination accumulation and helps evaluate the ability to perform clean transfer operations and glove change-outs

  15. Rocket Testing and Integrated System Health Management

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John

    2005-01-01

    Integrated System Health Management (ISHM) describes a set of system capabilities that in aggregate perform: determination of condition for each system element, detection of anomalies, diagnosis of causes for anomalies, and prognostics for future anomalies and system behavior. The ISHM should also provide operators with situational awareness of the system by integrating contextual and timely data, information, and knowledge (DIaK) as needed. ISHM capabilities can be implemented using a variety of technologies and tools. This chapter provides an overview of ISHM contributing technologies and describes in further detail a novel implementation architecture along with associated taxonomy, ontology, and standards. The operational ISHM testbed is based on a subsystem of a rocket engine test stand. Such test stands contain many elements that are common to manufacturing systems, and thereby serve to illustrate the potential benefits and methodologies of the ISHM approach for intelligent manufacturing.

  16. Analysis of Semiscale Mod-1 integral test with asymmetrical break (Test S-29-1)

    International Nuclear Information System (INIS)

    Langerman, M.A.

    1977-03-01

    Selected experimental data obtained from Semiscale Mod-1 cold leg break Test S-29-1 and results obtained from analytical codes are analyzed. This test was the first integral blowdown reflood test conducted with the Mod-1 system and was a special test designed specifically to evaluate the sensitivity of the early Mod-1 core thermal response (0 to 5 sec after rupture) to the magnitude and direction of the core flow. To achieve this specific objective in Test S-29-1, the vessel side break area was reduced to approximately one-half the scaled break area associated with a 200 percent cold leg break test. The reduction in break area significantly reduced the core flow reversal that took place immediately after rupture and resulted in periods of positive core flow in the early portion of the test. The results obtained from this test are compared with results obtained from a 200 percent cold leg break test and the effect of core flow on early core thermal response is evaluated. Since Test S-29-1 was the first integral blowdown reflood test conducted with the Mod-1 system, data are also presented through the reflood stage of the test and the results are analyzed. The test data and the core thermal response calculated with the RELAP4 code are also compared

  17. Integrated leak rate test of the FFTF [Fast Flux Test Facility] containment vessel

    International Nuclear Information System (INIS)

    Grygiel, M.L.; Davis, R.H.; Polzin, D.L.; Yule, W.D.

    1987-04-01

    The third integrated leak rate test (ILRT) performed at the Fast Flux Test Facility (FFTF) demonstrated that effective leak rate measurements could be obtained at a pressure of 2 psig. In addition, innovative data reduction methods demonstrated the ability to accurately account for diurnal variations in containment pressure and temperature. Further development of methods used in this test indicate significant savings in the time and effort required to perform an ILRT on Liquid Metal Reactor Systems with consequent reduction in test costs

  18. MWTF jumper connector integral seal block development and leak testing

    International Nuclear Information System (INIS)

    Ruff, E.S.; Jordan, S.R.

    1995-01-01

    In fiscal year 1993, tests of an o-ring/tetraseal retainer designed to replace a gasket-type seal used in PUREX-type process jumper connectors encouraged the design of an improved seal block. This new seal block combines several parts into one unitized component called an integral seal block. This report summarizes development and leak testing of the new integral seal block. The integral seal block uses a standard o-ring nested in a groove to accomplish leak tightness. This seal block eliminates the need to machine acme threads into the lower skirt casting and seal retainers, eliminates tolerance stack-up, reduces parts inventory, and eliminates an unnecessary leak path in the jumper connector assembly. This report also includes test data on various types of o-ring materials subjected to heat and pressure. Materials tested included Viton, Kalrez, and fluorosilicone, with some incidental data on teflon coated silicone o-rings. Test experience clearly demonstrates the need to test each seal material for temperature and pressure in its intended application. Some materials advertised as being open-quotes betterclose quotes at higher temperatures did not perform up to expectations. Inspection of the fluorosilicone and Kalrez seals after thermal testing indicates that they are much more susceptible to heat softening than Viton

  19. Comparison of Three Different Methods for Pile Integrity Testing on a Cylindrical Homogeneous Polyamide Specimen

    Science.gov (United States)

    Lugovtsova, Y. D.; Soldatov, A. I.

    2016-01-01

    Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.

  20. Integrating non-animal test information into an adaptive testing strategy - skin sensitization proof of concept case.

    Science.gov (United States)

    Jaworska, Joanna; Harol, Artsiom; Kern, Petra S; Gerberick, G Frank

    2011-01-01

    There is an urgent need to develop data integration and testing strategy frameworks allowing interpretation of results from animal alternative test batteries. To this end, we developed a Bayesian Network Integrated Testing Strategy (BN ITS) with the goal to estimate skin sensitization hazard as a test case of previously developed concepts (Jaworska et al., 2010). The BN ITS combines in silico, in chemico, and in vitro data related to skin penetration, peptide reactivity, and dendritic cell activation, and guides testing strategy by Value of Information (VoI). The approach offers novel insights into testing strategies: there is no one best testing strategy, but the optimal sequence of tests depends on information at hand, and is chemical-specific. Thus, a single generic set of tests as a replacement strategy is unlikely to be most effective. BN ITS offers the possibility of evaluating the impact of generating additional data on the target information uncertainty reduction before testing is commenced.

  1. Multiloop Integral System Test (MIST): MIST Facility Functional Specification

    International Nuclear Information System (INIS)

    Habib, T.F.; Koksal, C.G.; Moskal, T.E.; Rush, G.C.; Gloudemans, J.R.

    1991-04-01

    The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock ampersand Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST Functional Specification documents as-built design features, dimensions, instrumentation, and test approach. It also presents the scaling basis for the facility and serves to define the scope of work for the facility design and construction. 13 refs., 112 figs., 38 tabs

  2. Built-In Data-Flow Integration Testing in Large-Scale Component-Based Systems

    Science.gov (United States)

    Piel, Éric; Gonzalez-Sanchez, Alberto; Gross, Hans-Gerhard

    Modern large-scale component-based applications and service ecosystems are built following a number of different component models and architectural styles, such as the data-flow architectural style. In this style, each building block receives data from a previous one in the flow and sends output data to other components. This organisation expresses information flows adequately, and also favours decoupling between the components, leading to easier maintenance and quicker evolution of the system. Integration testing is a major means to ensure the quality of large systems. Their size and complexity, together with the fact that they are developed and maintained by several stake holders, make Built-In Testing (BIT) an attractive approach to manage their integration testing. However, so far no technique has been proposed that combines BIT and data-flow integration testing. We have introduced the notion of a virtual component in order to realize such a combination. It permits to define the behaviour of several components assembled to process a flow of data, using BIT. Test-cases are defined in a way that they are simple to write and flexible to adapt. We present two implementations of our proposed virtual component integration testing technique, and we extend our previous proposal to detect and handle errors in the definition by the user. The evaluation of the virtual component testing approach suggests that more issues can be detected in systems with data-flows than through other integration testing approaches.

  3. 16 CFR 1511.5 - Structural integrity tests.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Structural integrity tests. 1511.5 Section 1511.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... lowest position in the cylinder. If the uppermost edge of the component or fragment is below the plane of...

  4. Integration Tests of the Muon System

    CERN Multimedia

    Cerutti, F; Palestini, S

    A complex large-size prototype of the Muon system is installed in the test area H8B in Prévessin; the set-up includes chambers belonging to the three layers of the Barrel Spectrometer (on the right in Figure 1), and chambers belonging to one octant of the End Cap Spectrometer (center and left side of Figure 1). Figure 1: Set-up of the Muon spectrometer integration test. The installation accurately reproduces the geometry of regions of the ATLAS Muon Spectrometer, with the H8 beam-line crossing the detectors at positions/angles corresponding to particles with polar angle of 75 ± 4 and 15 ± 4 degrees, respectively for the Barrel and the End Cap. A comprehensive test program is being carried out with this set-up, ranging from tests of support frames (octant of the MDT BigWheel and of the SmallWheel) and of handling/installation of tracking chambers, to real-size tests of the alignment systems, together with accurate studies of performance and calibration of the precision chambers, and with develo...

  5. Comprehensive evaluation of future site alternatives

    International Nuclear Information System (INIS)

    Shain, D.I.; Jones, M.E.; Ryan, K.

    1994-01-01

    Due to rapid changes occurring within the Nuclear Weapons complex, the need for integrated planning designed to combine multiple program needs into one strategic plan has become a necessity. This is more apparent as diverse DOE programs compete for dwindling resources. These programs range from traditional production operations, environmental and waste management, to facility transition, economic development, decontamination and decommissioning, and environmental restoration activities. Each program can influence another, thus increasing the difficulty of distinguishing program elements. The method in developing comprehensive plans becomes even more complicated when environmental compliance issues, regulatory agreements and stakeholder values are considered. AT the Department of Energy's (DOE) Rocky Flats Plant (RFP), all of these program conditions exist. This paper addresses a set of tools which are being developed at RFP that provides key planning elements and alternatives assessment for the DOE's Office of Planning and Integration (OPI) and National Environmental Policy Act (NEPA) Compliance Officer at RFP. This set of tools is referred to as the Systems Engineering Analysis (SEA)

  6. Activation and waste disposal of the TITAN RFP [reversed-field-pinch] reactors

    International Nuclear Information System (INIS)

    Cheng, E.T.; Conn, R.W.

    1988-01-01

    The TITAN-I lithium self-cooled and TITAN-II aqueous lithium nitrate solution-cooled fusion reactors are based on the reversed-field-pinch (RFP) toroidal confinement concept and operate at high power density with an 18.1 MW/m 2 neutron wall loading. These designs were analyzed to study the activation and waste disposal aspects of such high-power density reactors. It was found that because of the use of V-3Ti-1Si (TITAN-I) and reduced activation ferritic steel (TITAN-II) as structural alloys for the first wall, blanket, reflector, and shield components, all the TITAN components except the divertor collector plates can be classified as shallow-land burial (10CFR61 Class C or better) nuclear waste for disposal, provided that the impurity elements, niobium and molybdenum, can be controlled below about 1 and 0.3 appm levels, respectively. The average annual disposal masses were estimated to be 150 and 96 tonnes, respectively, for the 1,000 MW TITAN-I and TITAN-II reactors. This corresponds to about 11% of the total mass in the fusion power core of both reactors. The divertor collector plates are fabricated with tungsten because of its low particle sputtering properties. These divertor collector plates in the TITAN-I reactor will be qualified as Class C waste after 18.1 MW-y/m 2 operation. The waste disposal rating of the divertor collector plates in the TITAN-II reactor, however, is estimated to be a factor of 4 higher than allowed for Class C disposal, because of the soft neutron spectrum in the beryllium environment. The annual disposal mass of this non-Class C waste is 0.35 tons, about 0.04% of the average annual discharge mass for the TITAN-II reactor. An additional 74 m 3 annual discharge of Class C waste containing 14 C may be needed for the TITAN-II reactor because of the use of nitrate salt in the aqueous coolant as the tritium breeder. 13 refs., 6 tabs

  7. Thermal-Hydraulic Integral Effect Test with the ATLS for Investigation on CEDM Penetration Nozzle Integrity

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyoungho; Seokcho; Park, Hyunsik; Choi, Namhyun; Park, Yusun; Kim, Jongrok; Bae, Byounguhn; Kim, Yeonsik; Choi, Kiyong; Song, Chulhwa [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    In this study, thermal-hydraulic integral effect test with the ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation) was performed for simulating a failure of CEDM penetration nozzle. The main objectives of the present test were not only to provide physical insight into the system response during a failure of CEDM penetration nozzle but also to establish an integral effect test database for the validation of the safety analysis codes. Furthermore, present experimental data were utilized to resolve the safety issue raised by the PWSCC at the CEDM penetration nozzle of the YGN-3. Thermal-hydraulic integral effect test with the ATLAS was performed for simulating a failure of CEDM penetration nozzle. Failure of two penetration nozzles of the CEDM in the APR1400 was simulated. Initial and boundary conditions were determined with respect to the reference conditions of the APR1400. However, with an aim of corresponding to the YGN-3 situation, the safety injection water was supplied via CLI mode. Compared to the cold leg break SBLOCA, the consequences of the event were milder in terms of a loop seal clearance, break flow rate, collapsed water level, and PCT. This could be mainly attributed to the small break flow rate in case of the failure in the RPV upper head. Present experimental data were utilized to resolve the safety issue raised by the PWSCC at the CEDM penetration nozzle of the YGN-3.

  8. Reactor benchmarks and integral data testing and feedback into ENDF/B-VI

    International Nuclear Information System (INIS)

    McKnight, R.D.; Williams, M.L.

    1992-01-01

    The role of integral data testing and its feedback into the ENDF/B evaluated nuclear data files are reviewed. The use of the CSEWG reactor benchmarks in the data testing process is discussed and selected results based on ENDF/B Version VI data are presented. Finally, recommendations are given to improve the implementation in future integral data testing of ENDF/B

  9. Analysis on working pressure selection of ACME integral test facility

    International Nuclear Information System (INIS)

    Chen Lian; Chang Huajian; Li Yuquan; Ye Zishen; Qin Benke

    2011-01-01

    An integral effects test facility, advanced core cooling mechanism experiment facility (ACME) was designed to verify the performance of the passive safety system and validate its safety analysis codes of a pressurized water reactor power plant. Three test facilities for AP1000 design were introduced and review was given. The problems resulted from the different working pressures of its test facilities were analyzed. Then a detailed description was presented on the working pressure selection of ACME facility as well as its characteristics. And the approach of establishing desired testing initial condition was discussed. The selected 9.3 MPa working pressure covered almost all important passive safety system enables the ACME to simulate the LOCAs with the same pressure and property similitude as the prototype. It's expected that the ACME design would be an advanced core cooling integral test facility design. (authors)

  10. Estimating and quantifying the impact of using models for integration and testing

    NARCIS (Netherlands)

    Braspenning, N.C.W.M.; Boumen, R.; Mortel - Fronczak, van de J.M.; Rooda, J.E.

    2011-01-01

    Industrial trends show that the lead time and costs of integrating and testing high-tech multi-disciplinary systems are becoming critical factors for commercial success. In our research, we developed a method for early, model-based integration and testing to reduce this criticality. Although its

  11. An integrated service excellence model for military test and ...

    African Journals Online (AJOL)

    The purpose of this article is to introduce an Integrated Service Excellence Model (ISEM) for empowering the leadership core of the capital-intensive military test and evaluation facilities to provide strategic military test and evaluation services and to continuously improve service excellence by ensuring that all activities ...

  12. Proportional and Integral Thermal Control System for Large Scale Heating Tests

    Science.gov (United States)

    Fleischer, Van Tran

    2015-01-01

    The National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) Flight Loads Laboratory is a unique national laboratory that supports thermal, mechanical, thermal/mechanical, and structural dynamics research and testing. A Proportional Integral thermal control system was designed and implemented to support thermal tests. A thermal control algorithm supporting a quartz lamp heater was developed based on the Proportional Integral control concept and a linearized heating process. The thermal control equations were derived and expressed in terms of power levels, integral gain, proportional gain, and differences between thermal setpoints and skin temperatures. Besides the derived equations, user's predefined thermal test information generated in the form of thermal maps was used to implement the thermal control system capabilities. Graphite heater closed-loop thermal control and graphite heater open-loop power level were added later to fulfill the demand for higher temperature tests. Verification and validation tests were performed to ensure that the thermal control system requirements were achieved. This thermal control system has successfully supported many milestone thermal and thermal/mechanical tests for almost a decade with temperatures ranging from 50 F to 3000 F and temperature rise rates from -10 F/s to 70 F/s for a variety of test articles having unique thermal profiles and test setups.

  13. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection c...... assessments. The test collection may be used for systems- as well as user-oriented evaluation.......he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...... constructed for this purpose. The test collection consists of approx. 18,000 monographic records, 160,000 papers and journal articles in PDF and 275,000 abstracts with a varied set of metadata and vocabularies from the physics domain, 65 topics based on real work tasks and corresponding graded relevance...

  14. Australian national networked tele-test facility for integrated systems

    Science.gov (United States)

    Eshraghian, Kamran; Lachowicz, Stefan W.; Eshraghian, Sholeh

    2001-11-01

    The Australian Commonwealth government recently announced a grant of 4.75 million as part of a 13.5 million program to establish a world class networked IC tele-test facility in Australia. The facility will be based on a state-of-the-art semiconductor tester located at Edith Cowan University in Perth that will operate as a virtual centre spanning Australia. Satellite nodes will be located at the University of Western Australia, Griffith University, Macquarie University, Victoria University and the University of Adelaide. The facility will provide vital equipment to take Australia to the frontier of critically important and expanding fields in microelectronics research and development. The tele-test network will provide state of the art environment for the electronics and microelectronics research and the industry community around Australia to test and prototype Very Large Scale Integrated (VLSI) circuits and other System On a Chip (SOC) devices, prior to moving to the manufacturing stage. Such testing is absolutely essential to ensure that the device performs to specification. This paper presents the current context in which the testing facility is being established, the methodologies behind the integration of design and test strategies and the target shape of the tele-testing Facility.

  15. Integral data testing of JENDL-3.2 for fusion reactor and shielding applications

    International Nuclear Information System (INIS)

    Oyama, Yukio

    1995-01-01

    Integral data testing of JENDL-3.2 is being performed in the activities of two working groups of the Japanese Nuclear Data Committee. The continuous and group-wise libraries prepared from JENDL-3.2 are planned to be tested by the working groups. In this paper, the continuous library FSXLIB-J3R2 processed from JENDL-3.2 for MCNP was tested for fission and fusion neutrons using data of integral experiments and compared to the results of JENDL-3.1. The results of integral data testing of JENDL-3.2 for fusion and shielding application are reviewed. (author)

  16. Reactor building integrity testing: A novel approach at Gentilly 2 - principles and methodology

    International Nuclear Information System (INIS)

    Collins, N.; Lafreniere, P.

    1991-01-01

    In 1987, Hydro-Quebec embarked on an ambitious development program to provide the Gentilly 2 nuclear power station with an effective, yet practical reactor building Integrity Test. The Gentilly 2 Integrity Test employs an innovative approach based on the reference volume concept. It is identified as the Temperature Compensation Method (TCM) System. This configuration has been demonstrated at both high and low test pressure and has achieved extraordinary precision in the leak rate measurement. The Gentilly 2 design allows the Integrity Test to be performed at a nominal 3 kPa(g) test pressure during an (11) hour period with the reactor at full power. The reactor building Pressure Test by comparison, is typically performed at high pressure 124 kPa(g)) in a 7 day window during an annual outage. The Integrity Test was developed with the goal of demonstrating containment availability. Specifically it was purported to detect a leak or hole in the 'bottled-up' reactor building greater in magnitude than an equivalent pipe of 25 mm diameter. However it is considered feasible that the high precision of the Gentilly 2 TCM System Integrity Test and a stable reactor building leak characteristic will constitute sufficient grounds for the reduction of the Pressure Test frequency. It is noted that only the TCM System has, to this date, allowed a relevant determination of the reactor building leak rate at a nominal test pressure of 3 kPa(g). Classical method tests at low pressure have lead to inconclusive results due to the high lack of precision

  17. Summarisation of construction and commissioning experience for nuclear power integrated test facility

    International Nuclear Information System (INIS)

    Xiao Zejun; Jia Dounan; Jiang Xulun; Chen Bingde

    2003-01-01

    Since the foundation of Nuclear Power Institute of China, it has successively designed various engineering experimental facilities, and constructed nuclear power experimental research base, and accumulated rich construction experiences of nuclear power integrated test facility. The author presents experience on design, construction and commissioning of nuclear power integrated test facility

  18. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  19. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  20. Development and Testing of an Integrated Sandia Cooler Thermoelectric Device (SCTD).

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Terry A.; Staats, Wayne Lawrence,; Leick, Michael Thomas; Zimmerman, Mark D.; Radermacher, Reinhard; Martin, Cara; Nasuta, Dennis; Kalinowski, Paul; Hoffman, William

    2014-12-01

    This report describes a FY14 effort to develop an integrated Sandia Cooler T hermoelectric D evice (SCTD) . The project included a review of feasible thermoelectric (TE) cooling applications, baseline performance testing of an existing TE device, analysis and design development of an integrated SCTD assembly, and performance measurement and validation of the integrated SCTD prototype.

  1. Autonomous Star Tracker Algorithms

    DEFF Research Database (Denmark)

    Betto, Maurizio; Jørgensen, John Leif; Kilsgaard, Søren

    1998-01-01

    Proposal, in response to an ESA R.f.P., to design algorithms for autonomous star tracker operations.The proposal also included the development of a star tracker breadboard to test the algorithms performances.......Proposal, in response to an ESA R.f.P., to design algorithms for autonomous star tracker operations.The proposal also included the development of a star tracker breadboard to test the algorithms performances....

  2. Structural design and manufacturing of TPE-RX vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Sago, H.; Orita, J.; Kaguchi, H.; Ishigami, Y. [Mitsubishi Heavy Ind. Ltd., Kobe (Japan); Urata, K.; Kudough, F. [Mitsubishi Heavy Industries, Ltd., Tokyo (Japan); Hasegawa, M.; Oyabu, I. [Mitsubishi Electric Co., Tokyo (Japan); Yagi, Y.; Sekine, S.; Shimada, T.; Hirano, Y.; Sakakita, H.; Koguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan)

    1999-10-01

    TPE-RX is a newly constructed, large-sized reversed field pinch (RFP) machine installed at the Electrotechnical Laboratory of the Ministry of International Trade and Industry in Japan. This is the third largest RFP in the world. Major and minor radii of the plasma are 1.72 and 0.45 m, respectively. TPE-RX aims to optimize plasma confinement up to 1 MA. RFP plasma configuration was successfully obtained in March 1998. This paper reports the structural design and manufacturing of the vacuum vessel of TPE-RX. The supporting system on the bellows sections of the vessel was designed based on a detailed finite element method. The integrity of the vacuum vessel against a plasma disruption has been confirmed using dynamic inelastic analyses. (orig.)

  3. Structural design and manufacturing of TPE-RX vacuum vessel

    International Nuclear Information System (INIS)

    Sago, H.; Orita, J.; Kaguchi, H.; Ishigami, Y.; Urata, K.; Kudough, F.; Hasegawa, M.; Oyabu, I.; Yagi, Y.; Sekine, S.; Shimada, T.; Hirano, Y.; Sakakita, H.; Koguchi, H.

    1999-01-01

    TPE-RX is a newly constructed, large-sized reversed field pinch (RFP) machine installed at the Electrotechnical Laboratory of the Ministry of International Trade and Industry in Japan. This is the third largest RFP in the world. Major and minor radii of the plasma are 1.72 and 0.45 m, respectively. TPE-RX aims to optimize plasma confinement up to 1 MA. RFP plasma configuration was successfully obtained in March 1998. This paper reports the structural design and manufacturing of the vacuum vessel of TPE-RX. The supporting system on the bellows sections of the vessel was designed based on a detailed finite element method. The integrity of the vacuum vessel against a plasma disruption has been confirmed using dynamic inelastic analyses. (orig.)

  4. Feasibility and willingness-to-pay for integrated community-based tuberculosis testing

    Directory of Open Access Journals (Sweden)

    Vickery Carter

    2011-11-01

    Full Text Available Abstract Background Community-based screening for TB, combined with HIV and syphilis testing, faces a number of barriers. One significant barrier is the value that target communities place on such screening. Methods Integrated testing for TB, HIV, and syphilis was performed in neighborhoods identified using geographic information systems-based disease mapping. TB testing included skin testing and interferon gamma release assays. Subjects completed a survey describing disease risk factors, healthcare access, healthcare utilization, and willingness to pay for integrated testing. Results Behavioral and social risk factors among the 113 subjects were prevalent (71% prior incarceration, 27% prior or current crack cocaine use, 35% homelessness, and only 38% had a regular healthcare provider. The initial 24 subjects reported that they would be willing to pay a median $20 (IQR: 0-100 for HIV testing and $10 (IQR: 0-100 for TB testing when the question was asked in an open-ended fashion, but when the question was changed to a multiple-choice format, the next 89 subjects reported that they would pay a median $5 for testing, and 23% reported that they would either not pay anything to get tested or would need to be paid $5 to get tested for TB, HIV, or syphilis. Among persons who received tuberculin skin testing, only 14/78 (18% participants returned to have their skin tests read. Only 14/109 (13% persons who underwent HIV testing returned to receive their HIV results. Conclusion The relatively high-risk persons screened in this community outreach study placed low value on testing. Reported willingness to pay for such testing, while low, likely overestimated the true willingness to pay. Successful TB, HIV, and syphilis integrated testing programs in high risk populations will likely require one-visit diagnostic testing and incentives.

  5. Integration test effort in SAP R/3 systems

    NARCIS (Netherlands)

    Griend, van de P.A.; Kusters, R.J.

    2012-01-01

    This paper describes an experimental approach towards the definition of a metric for integration test effort based on enterprise resource planning (ERP) system logs. By nature, ERP systems are complex. After implementing an ERP-system, it is typically subjected to many, and often concurrent,

  6. Integrated Human Test Facilities at NASA and the Role of Human Engineering

    Science.gov (United States)

    Tri, Terry O.

    2002-01-01

    Integrated human test facilities are a key component of NASA's Advanced Life Support Program (ALSP). Over the past several years, the ALSP has been developing such facilities to serve as a large-scale advanced life support and habitability test bed capable of supporting long-duration evaluations of integrated bioregenerative life support systems with human test crews. These facilities-targeted for evaluation of hypogravity compatible life support and habitability systems to be developed for use on planetary surfaces-are currently in the development stage at the Johnson Space Center. These major test facilities are comprised of a set of interconnected chambers with a sealed internal environment, which will be outfitted with systems capable of supporting test crews of four individuals for periods exceeding one year. The advanced technology systems to be tested will consist of both biological and physicochemical components and will perform all required crew life support and habitability functions. This presentation provides a description of the proposed test "missions" to be supported by these integrated human test facilities, the overall system architecture of the facilities, the current development status of the facilities, and the role that human design has played in the development of the facilities.

  7. Cryo Testing of tbe James Webb Space Telescope's Integrated Science Instrument Module

    Science.gov (United States)

    VanCampen, Julie

    2004-01-01

    The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope will be integrated and tested at the Environmental Test Facilities at Goddard Space Flight Center (GSFC). The cryogenic thermal vacuum testing of the ISIM will be the most difficult and problematic portion of the GSFC Integration and Test flow. The test is to validate the coupled interface of the science instruments and the ISIM structure and to sufficiently stress that interface while validating image quality of the science instruments. The instruments and the structure are not made from the same materials and have different CTE. Test objectives and verification rationale are currently being evaluated in Phase B of the project plan. The test program will encounter engineering challenges and limitations, which are derived by cost and technology many of which can be mitigated by facility upgrades, creative GSE, and thorough forethought. The cryogenic testing of the ISIM will involve a number of risks such as the implementation of unique metrology techniques, mechanical, electrical and optical simulators housed within the cryogenic vacuum environment. These potential risks are investigated and possible solutions are proposed.

  8. Recent development in low-constraint fracture toughness testing for structural integrity assessment of pipelines

    Science.gov (United States)

    Kang, Jidong; Gianetto, James A.; Tyson, William R.

    2018-03-01

    Fracture toughness measurement is an integral part of structural integrity assessment of pipelines. Traditionally, a single-edge-notched bend (SE(B)) specimen with a deep crack is recommended in many existing pipeline structural integrity assessment procedures. Such a test provides high constraint and therefore conservative fracture toughness results. However, for girth welds in service, defects are usually subjected to primarily tensile loading where the constraint is usually much lower than in the three-point bend case. Moreover, there is increasing use of strain-based design of pipelines that allows applied strains above yield. Low-constraint toughness tests represent more realistic loading conditions for girth weld defects, and the corresponding increased toughness can minimize unnecessary conservatism in assessments. In this review, we present recent developments in low-constraint fracture toughness testing, specifically using single-edgenotched tension specimens, SENT or SE(T). We focus our review on the test procedure development and automation, round-robin test results and some common concerns such as the effect of crack tip, crack size monitoring techniques, and testing at low temperatures. Examples are also given of the integration of fracture toughness data from SE(T) tests into structural integrity assessment.

  9. Multiloop integral system test (MIST): Final report, Inter-group comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Gloudemans, J.R.

    1989-07-01

    The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock and Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility -- the once-through integral system (OTIS) -- was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The individual tests are described in detail in Volumes 2 through 8 and Volume 11, and are summarized in Volume 1. Inter-group comparisons are addressed in this document, Volume 9. These comparisons are grouped as follows: mapping versus SBLOCA transients, SBLOCA, pump effects, and the effects of noncondensible gases. Appendix A provides an index and description of the microfiched plots for each test, which are enclosed with the corresponding Volumes 2 through 8. 147 figs., 5 tabs.

  10. Integrated Electrical and Thermal Grid Facility - Testing of Future Microgrid Technologies

    Directory of Open Access Journals (Sweden)

    Sundar Raj Thangavelu

    2015-09-01

    Full Text Available This paper describes the Experimental Power Grid Centre (EPGC microgrid test facility, which was developed to enable research, development and testing for a wide range of distributed generation and microgrid technologies. The EPGC microgrid facility comprises a integrated electrical and thermal grid with a flexible and configurable architecture, and includes various distributed energy resources and emulators, such as generators, renewable, energy storage technologies and programmable load banks. The integrated thermal grid provides an opportunity to harness waste heat produced by the generators for combined heat, power and cooling applications, and support research in optimization of combined electrical-thermal systems. Several case studies are presented to demonstrate the testing of different control and operation strategies for storage systems in grid-connected and islanded microgrids. One of the case studies also demonstrates an integrated thermal grid to convert waste heat to useful energy, which thus far resulted in a higher combined energy efficiency. Experiment results confirm that the facility enables testing and evaluation of grid technologies and practical problems that may not be apparent in a computer simulated environment.

  11. Simulation of integral local tests with high-burnup fuel

    International Nuclear Information System (INIS)

    Gyori, G.

    2011-01-01

    The behaviour of nuclear fuel under LOCA conditions may strongly depend on the burnup-dependent fuel characteristics, as it has been indicated by recent integral experiments. Fuel fragmentation and the associated fission gas release can influence the integral fuel behaviour, the rod rupture and the radiological release. The TRANSURANUS fuel performance code is a proper tool for the consistent simulation of burnup-dependent phenomena during normal operation and the thermo-mechanical behaviour of the fuel rod in a subsequent accident. The code has been extended with an empirical model for micro-cracking induced FGR and fuel fragmentation and verified against integral LOCA tests of international projects. (author)

  12. Co-integration Rank Testing under Conditional Heteroskedasticity

    DEFF Research Database (Denmark)

    Cavaliere, Guiseppe; Rahbæk, Anders; Taylor, A.M. Robert

    null distributions of the rank statistics coincide with those derived by previous authors who assume either i.i.d. or (strict and covariance) stationary martingale difference innovations. We then propose wild bootstrap implementations of the co-integrating rank tests and demonstrate that the associated...... bootstrap rank statistics replicate the first-order asymptotic null distributions of the rank statistics. We show the same is also true of the corresponding rank tests based on the i.i.d. bootstrap of Swensen (2006). The wild bootstrap, however, has the important property that, unlike the i.i.d. bootstrap......, it preserves in the re-sampled data the pattern of heteroskedasticity present in the original shocks. Consistent with this, numerical evidence sug- gests that, relative to tests based on the asymptotic critical values or the i.i.d. bootstrap, the wild bootstrap rank tests perform very well in small samples un...

  13. Integration and test plans for complex manufacturing systems

    NARCIS (Netherlands)

    Boumen, R.

    2007-01-01

    The integration and test phases that are part of the development and manufacturing of complex manufacturing systems are costly and time consuming. As time-to-market is becoming increasingly important, it is crucial to keep these phases as short as possible, whilemaintaining system quality. This is

  14. Natural circulation in an integral CANDU test facility

    International Nuclear Information System (INIS)

    Ingham, P.J.; Sanderson, T.V.; Luxat, J.C.; Melnyk, A.J.

    2000-01-01

    Over 70 single- and two-phase natural circulation experiments have been completed in the RD-14M facility, an integral CANDU thermalhydraulic test loop. This paper describes the RD-14M facility and provides an overview of the impact of key parameters on the results of natural circulation experiments. Particular emphasis will be on phenomena which led to heat up at high system inventories in a small subset of experiments. Clarification of misunderstandings in a recently published comparison of the effectiveness of natural circulation flows in RD-14M to integral facilities simulating other reactor geometries will also be provided. (author)

  15. Integration Test of the High Voltage Hall Accelerator System Components

    Science.gov (United States)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Pinero, Luis; Peterson, Todd; Dankanich, John

    2013-01-01

    NASA Glenn Research Center is developing a 4 kilowatt-class Hall propulsion system for implementation in NASA science missions. NASA science mission performance analysis was completed using the latest high voltage Hall accelerator (HiVHAc) and Aerojet-Rocketdyne's state-of-the-art BPT-4000 Hall thruster performance curves. Mission analysis results indicated that the HiVHAc thruster out performs the BPT-4000 thruster for all but one of the missions studied. Tests of the HiVHAc system major components were performed. Performance evaluation of the HiVHAc thruster at NASA Glenn's vacuum facility 5 indicated that thruster performance was lower than performance levels attained during tests in vacuum facility 12 due to the lower background pressures attained during vacuum facility 5 tests when compared to vacuum facility 12. Voltage-Current characterization of the HiVHAc thruster in vacuum facility 5 showed that the HiVHAc thruster can operate stably for a wide range of anode flow rates for discharge voltages between 250 and 600 volts. A Colorado Power Electronics enhanced brassboard power processing unit was tested in vacuum for 1,500 hours and the unit demonstrated discharge module efficiency of 96.3% at 3.9 kilowatts and 650 volts. Stand-alone open and closed loop tests of a VACCO TRL 6 xenon flow control module were also performed. An integrated test of the HiVHAc thruster, brassboard power processing unit, and xenon flow control module was performed and confirmed that integrated operation of the HiVHAc system major components. Future plans include continuing the maturation of the HiVHAc system major components and the performance of a single-string integration test.

  16. Automatic integrated testing bench for tubes in translation

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Perdijon, J.

    1976-01-01

    All the nondestructive tests required for receiving the cladding tubes intended for fast nuclear reactor are integrated on this bench: quality control by eddy currents and ultra-sounds, thickness and (inner and outer) diameter measurement. The linear displacement of the tube allows very high rates to be attained [fr

  17. 49 CFR 1546.409 - Integrity of screener tests.

    Science.gov (United States)

    2010-10-01

    ... security supervisor, or other screening supervisor. The employee must be familiar with the procedures for... Qualifications When the Foreign Air Carrier Conducts Screening § 1546.409 Integrity of screener tests. (a... than one foreign air carrier or foreign air carrier uses a screening location, TSA may authorize an...

  18. Design and manufacturing of vacuum vessel of TPE-RX

    Energy Technology Data Exchange (ETDEWEB)

    Sago, H.; Kaguchi, H.; Orita, J.; Ishigami, Y. [Mitsubishi Heavy Industries Ltd., Kobe (Japan); Urata, K. [Mitsubishi Heavy Industries Ltd. (Japan). Nuclear Energy Systems Engineering Center; Hasegawa, M. [Mitsubishi Electric Co. (Japan). Nuclear Fusion Development; Yagi, Y.; Hirano, Y.; Shimada, T.; Sekine, S.; Sakakita, H. [Electrotechnical Lab. (Japan)

    1998-07-01

    Construction of a new, large reversed field pinch (RFP) machine called TPE-RX was complete at the end of 1997 as a successor of the previous TPE-1RM20 machine at the Electrotechnical Laboratory (ETL). RFP configuration has been successfully obtained in March 1998. This paper introduces structural design and manufacturing of the vacuum vessel of TPE-RX. The support positions were decided by structural analyses. The structural integrity of the vacuum vessel was evaluated by inelastic analyses. (author)

  19. Design and manufacturing of vacuum vessel of TPE-RX

    International Nuclear Information System (INIS)

    Sago, H.; Kaguchi, H.; Orita, J.; Ishigami, Y.; Urata, K.

    1998-01-01

    Construction of a new, large reversed field pinch (RFP) machine called TPE-RX was complete at the end of 1997 as a successor of the previous TPE-1RM20 machine at the Electrotechnical Laboratory (ETL). RFP configuration has been successfully obtained in March 1998. This paper introduces structural design and manufacturing of the vacuum vessel of TPE-RX. The support positions were decided by structural analyses. The structural integrity of the vacuum vessel was evaluated by inelastic analyses. (author)

  20. Integral test of JENDL fusion file

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Fujio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    Integral test of JENDL Fusion File (J-FF) is performed through analyses of available benchmark experiments. As a result, good agreement between the calculated results with J-FF and the measured data is observed as a whole. Thus, J-FF is qualified to be used for nuclear design of fusion reactors. Owing to the high quality evaluation of J-FF, cross section data in J-FF for many nuclides are recommended to be assigned as data in FENDL/E-2.0 in the IAEA Consultants` Meeting held at Karlsruhe, Germany, 24-28 June, 1996. (author)

  1. Integrated dry NO{sub x}/SO{sub 2} emissions control system: integrated system test report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.A.; Muzio, L.J. [Fossil Energy Research Corp., Laguna Hills, CA (United States); Hunt, T. [Public Service Co. of Colorado, Denver, CO (United States)

    1997-04-01

    The DOE sponsored Integrated Dry NO{sub x}/SO{sub 2} Emissions Control System Program, is a Clean Coal Technology III demonstration, being conducted by Public Service Company of Colorado. The test site is Arapahoe Generating Station Unit 4, a 100 MWe, down-fired utility boiler burning a low-sulfur Western coal. The project goal is to demonstrate up to 70 percent reductions in NO{sub x} and SO{sub 2} emissions through the integration of: (1) down-fired low NO{sub x} burners with overfire air; (2) Selective Non-Catalytic Reduction (SNCR) for additional NO{sub x} removal; and (3) Dry Sorbent Injection (DSI) and duct humidification for SO{sub 2} removal. This report documents the final phase of the test program, in which the overall performance of the integrated system was evaluated. Previous testing has shown that the goal of 70 percent NO{sub x} removal was easily achieved with the combination of low-NO{sub x} burners, overfire air, and urea-based SNCR. Similarly, the ability of the sodium-based DSI system to achieve 70 percent SO{sub 2} removal was also demonstrated previously. The integrated tests demonstrated the synergistic benefit of operating the SNCR and sodium-based DSI systems concurrently. With the automatic control system set to limit the NH{sub 3} emissions to less than 8 ppm, the NO{sub 2} emissions from the sodium-based DSI system were reduced by nominally 50 percent compared to operation with the DSI system alone. Comparably, the combined operation reduced NH{sub 3} emissions, as reflected by a higher urea injection rate for a fixed NH{sub 3} emission limit. With combined DSI and SNCR operation, an ammonia odor problem was encountered around the Unit 4 ash silo (this did not occur with the SNCR system operated alone at comparable NH{sub 3} slip levels). This odor problem is attributed to the sodium changing the rate at which NH{sub 3} is released from the ash when it is wetted for truck transport to the disposal site.

  2. Direct comparison of unloading compliance and potential drop techniques in J-integral testing

    International Nuclear Information System (INIS)

    McGowan, J.J.; Nanstad, R.K.

    1984-01-01

    Single-specimen J-integral testing is performed commonly with the unloading compliance technique. Use of modern instrumentation techniques and powerful desktop computers have made this technique a standard. However, this testing technique is slow and tedious, with the loading rate fixed at a slow quasi-static rate. For these reasons the dc potential drop technique was investigated for crack length measurement during a J-integral test. For direct comparison, both unloading compliance and potential drop were used simultaneously during a J-integral test. The results showed good agreement between the techniques. However, the potential drop technique showed an offset in crack length due to plastic blunting processes. Taking this offset into account, J/sub Ic/ values calculated by both techniques compared well

  3. Safety measures for integrity test apparatus for IS process. Sulfuric acid decomposition section

    International Nuclear Information System (INIS)

    Noguchi, Hiroki; Kubo, Shinji; Iwatsuki, Jin; Onuki, Kaoru

    2013-07-01

    Hazardous substances such as sulfuric acid, sulfur dioxide and hydrogen iodide acid are employed in thermochemical Iodine-Sulfur (IS) process. It is necessary to take safety measure against workers and external environments to study experimentally on IS process. Presently we have been conducting to verify the soundness of main components made of engineering material in actual corrosive condition. An integrity test apparatus for the components of sulfuric acid decomposition was set up. We will use the hazardous substances such as sulfuric acid and sulfur dioxide and perform the experiment in pressurized condition in this integrity test. Safety measures for the test apparatus, operation and abnormal situation were considered prior to starting the test. This report summarized the consideration results for the safety measures on the integrity test apparatus for the components of sulfuric acid decomposition. (author)

  4. Integration of test modules in the main blanket and vacuum vessel design

    International Nuclear Information System (INIS)

    Nakahira, Masataka; Kurasawa, Toshimasa; Sato, Satoshi; Furuya, Kazuyuki; Togami, Ikuhide; Hashimoto, Toshiyuki; Takatsu, Hideyuki; Kuroda, Toshimasa.

    1995-07-01

    Typical test modules for water-cooled and helium-cooled ceramic breeder blankets have been designed, and their major design parameters are summarized. Among various candidates studied in Japan at present, BOT (Breeder Out of Tube) type of blanket is exemplified here. The integration scheme of the test module into ITER basic machine is also shown. Even with other type of blanket, the integration scheme won't be affected. The composition and space requirement of cooling and tritium recovery systems for the test module have also been studied. (author)

  5. Integrated leak rate testing of the fast flux test facility reactor containment building

    International Nuclear Information System (INIS)

    James, E.B.; Farabee, O.A.; Bliss, R.J.

    1978-01-01

    The initial Integrated Leak Rate Test (ILRT) of the Fast Flux Test Facility containment building was performed from May 27 to June 2, 1978. The test was conducted in air with systems vented and with the containment recirculating coolers in operation. 10 psig and 5 psig tests were run using the absolute pressure test method. The measured leakage rates were .033% Vol/24 hr. and -.0015% Vol/24 hrs. respectively. Subsequent verification tests at both 10 psig and 5 psig proved that the test equipment was operating properly and it was sensitive enough to detect leaks at low pressures. This ILRT was performed at a lower pressure than any previous ILRT on a reactor containment structure in the United States. While the initial design requirements for ice condenser containments called for a part pressure test at 6 psig, the tests were waived due to the apparent statistical problems of data analysis and the repeatability of the data itself at such low pressure. In contrast to this belief, both the 5 and 10 psig ILRT's were performed in a successful manner at FFTF

  6. Test processing integrated system (S.I.D.E.X.)

    International Nuclear Information System (INIS)

    Sabas, M.; Oules, H.; Badel, D.

    1969-01-01

    The Test Processing Integrated System is mostly composed of a CAE 9080 (equiv. S. D. S. 9300) computer which is equipped of a 100 000 samples/sec acquisition system. The System is designed for high speed data acquisition and data processing on environment tests, and also calculation of structural models. Such a digital appliance on data processing has many advantages compared to the conventional methods based on analog instruments. (author) [fr

  7. Testing for co-integration in vector autoregressions with non-stationary volatility

    DEFF Research Database (Denmark)

    Cavaliere, Giuseppe; Rahbek, Anders Christian; Taylor, Robert M.

    2010-01-01

    cases. We show that the conventional rank statistics computed as in (Johansen, 1988) and (Johansen, 1991) are potentially unreliable. In particular, their large sample distributions depend on the integrated covariation of the underlying multivariate volatility process which impacts on both the size...... and power of the associated co-integration tests, as we demonstrate numerically. A solution to the identified inference problem is provided by considering wild bootstrap-based implementations of the rank tests. These do not require the practitioner to specify a parametric model for volatility, or to assume...

  8. Testing for Level Shifts in Fractionally Integrated Processes: a State Space Approach

    DEFF Research Database (Denmark)

    Monache, Davide Delle; Grassi, Stefano; Santucci de Magistris, Paolo

    Short memory models contaminated by level shifts have similar long-memory features as fractionally integrated processes. This makes hard to verify whether the true data generating process is a pure fractionally integrated process when employing standard estimation methods based on the autocorrela......Short memory models contaminated by level shifts have similar long-memory features as fractionally integrated processes. This makes hard to verify whether the true data generating process is a pure fractionally integrated process when employing standard estimation methods based...... on the autocorrelation function or the periodogram. In this paper, we propose a robust testing procedure, based on an encompassing parametric specification that allows to disentangle the level shifts from the fractionally integrated component. The estimation is carried out on the basis of a state-space methodology...... and it leads to a robust estimate of the fractional integration parameter also in presence of level shifts. Once the memory parameter is correctly estimated, we use the KPSS test for presence of level shift. The Monte Carlo simulations show how this approach produces unbiased estimates of the memory parameter...

  9. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    Science.gov (United States)

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  10. Integrated Testlets: A New Form of Expert-Student Collaborative Testing

    Science.gov (United States)

    Shiell, Ralph C.; Slepkov, Aaron D.

    2015-01-01

    Integrated testlets are a new assessment tool that encompass the procedural benefits of multiple-choice testing, the pedagogical advantages of free-response-based tests, and the collaborative aspects of a viva voce or defence examination format. The result is a robust assessment tool that provides a significant formative aspect for students.…

  11. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  12. Thermal Vacuum Integrated System Test at B-2

    Science.gov (United States)

    Kudlac, Maureen T.; Weaver, Harold F.; Cmar, Mark D.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) Plum Brook Station (PBS) Space Propulsion Research Facility, commonly referred to as B-2, is NASA s third largest thermal vacuum facility. It is the largest designed to store and transfer large quantities of liquid hydrogen and liquid oxygen, and is perfectly suited to support developmental testing of chemical propulsion systems as well as fully integrated stages. The facility is also capable of providing thermal-vacuum simulation services to support testing of large lightweight structures, Cryogenic Fluid Management (CFM) systems, electric propulsion test programs, and other In-Space propulsion programs. A recently completed integrated system test demonstrated the refurbished thermal vacuum capabilities of the facility. The test used the modernized data acquisition and control system to monitor the facility during pump down of the vacuum chamber, operation of the liquid nitrogen heat sink (or cold wall) and the infrared lamp array. A vacuum level of 1.3x10(exp -4)Pa (1x10(exp -6)torr) was achieved. The heat sink provided a uniform temperature environment of approximately 77 K (140deg R) along the entire inner surface of the vacuum chamber. The recently rebuilt and modernized infrared lamp array produced a nominal heat flux of 1.4 kW/sq m at a chamber diameter of 6.7 m (22 ft) and along 11 m (36 ft) of the chamber s cylindrical vertical interior. With the lamp array and heat sink operating simultaneously, the thermal systems produced a heat flux pattern simulating radiation to space on one surface and solar exposure on the other surface. The data acquired matched pretest predictions and demonstrated system functionality.

  13. Integration of HIV testing in tuberculosis drug resistance surveillance in Kazakhstan and Kenya

    NARCIS (Netherlands)

    Klinkenberg, E.; van den Hof, S.; Tursynbayeva, A.; Kipruto, H.; Wahogo, J.; Pak, S.; Kutwa, A.; L'Herminez, R.

    2012-01-01

    In Kenya and Kazakhstan, integration of human immunodeficiency virus (HIV) testing results into the routine surveillance of multidrug-resistant tuberculosis (MDR-TB) proved feasible and useful. The integration process improved overall data quality and data validation capacity, and integrated data

  14. A seal analyzer for testing container integrity

    International Nuclear Information System (INIS)

    McDaniel, P.; Jenkins, C.

    1988-01-01

    This paper reports on the development of laboratory and production seal analyzer that offers a rapid, nondestructive method of assuring the seal integrity of virtually any type of single or double sealed container. The system can test a broad range of metal cans, drums and trays, membrane-lidded vessels, flexible pouches, aerosol containers, and glass or metal containers with twist-top lids that are used in the chemical/pesticide (hazardous materials/waste), beverage, food, medical and pharmaceutical industries

  15. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  16. Structural testing of the technology integration box beam

    Science.gov (United States)

    Griffin, C. F.

    1992-01-01

    A full-scale section of a transport aircraft wing box was designed, analyzed, fabricated, and tested. The wing box section, which was called the technology integration box beam, contained blade stiffened covers and T-stiffened channel spars constructed using graphite/epoxy materials. Covers, spars, and the aluminum ribs were assembled using mechanical fasteners. The box beam was statically tested for several loading conditions to verify the stiffness and strength characteristics of the composite wing design. Failure of the box beam occurred at 125 percent of design limit load during the combined upbending and torsion ultimate design load test. It appears that the failure initiated at a stiffener runout location in the upper cover which resulted in rupture of the upper cover and portions of both spars.

  17. Space Station Freedom environmental control and life support system phase 3 simplified integrated test detailed report

    Science.gov (United States)

    Roberts, B. C.; Carrasquillo, R. L.; Dubiel, M. Y.; Ogle, K. Y.; Perry, J. L.; Whitley, K. M.

    1990-01-01

    A description of the phase 3 simplified integrated test (SIT) conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) in 1989 is presented. This was the first test in the phase 3 series integrated environmental control and life support systems (ECLSS) tests. The basic goal of the SIT was to achieve full integration of the baseline air revitalization (AR) subsystems for Space Station Freedom. Included is a description of the SIT configuration, a performance analysis of each subsystem, results from air and water sampling, and a discussion of lessons learned from the test. Also included is a full description of the preprototype ECLSS hardware used in the test.

  18. The Rapid Integration and Test Environment - A Process for Achieving Software Test Acceptance

    OpenAIRE

    Jack, Rick

    2010-01-01

    Proceedings Paper (for Acquisition Research Program) Approved for public release; distribution unlimited. The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office, Command, Control, Communications, Computers and Intelligence, Command and Control Program Office (PMW-150), was born of necessity. Existing processes for requirements definition and management, as well as those for software development, did not consistently deliver high-qualit...

  19. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  20. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  1. Integrated radiobioecological monitoring of Semipalatinsk test site: general approach

    International Nuclear Information System (INIS)

    Sejsebaev, A.T.; Shenal', K.; Bakhtin, M.M.; Kadyrova, N.Zh.

    2001-01-01

    This paper presents major research directions and general methodology for establishment of an integrated radio-bio-ecological monitoring system at the territory of the former Semipalatinsk nuclear test site. Also, it briefly provides the first results of monitoring the natural plant and animal populations at STS. (author)

  2. Integration and Testing Challenges of Small Satellite Missions: Experiences from the Space Technology 5 Project

    Science.gov (United States)

    Sauerwein, Timothy A.; Gostomski, Tom

    2007-01-01

    The Space Technology 5(ST5) payload was successfully carried into orbit on an OSC Pegasus XL launch vehicle, which was carried aloft and dropped from the OSC Lockheed L-1011 from Vandenberg Air Force Base March 22,2006, at 9:03 am Eastern time, 6:03 am Pacific time. In order to reach the completion of the development and successful launch of ST 5, the systems integration and test(I&T) team determined that a different approach was required to meet the project requirements rather than the standard I&T approach used for single, room-sized satellites. The ST5 payload, part of NASA's New Millennium Program headquartered at JPL, consisted of three micro satellites (approximately 30 kg each) and the Pegasus Support Structure (PSS), the system that connected the spacecrafts to the launch vehicle and deployed the spacecrafts into orbit from the Pegasus XL launch vehicle. ST5 was a technology demonstration payload, intended to test six (6) new technologies for potential use for future space flights along with demonstrating the ability of small satellites to perform quality science. The main technology was a science grade magnetometer designed to take measurements of the earth's magnetic field. The three spacecraft were designed, integrated, and tested at NASA Goddard Space Flight Center with integration and environmental testing occurring in the Bldg. 7-1 0-15-29. The three spacecraft were integrated and tested by the same I&T team. The I&T Manager determined that there was insufficient time in the schedule to perform the three I&T spacecraft activities in series used standard approaches. The solution was for spacecraft #1 to undergo integration and test first, followed by spacecraft #2 and #3 simultaneously. This simultaneous integration was successful for several reasons. Each spacecraft had a Lead Test Conductor who planned and coordinated their spacecraft through its integration and test activities. One team of engineers and technicians executed the integration of all

  3. Price transmission and market integration: a test of the central ...

    African Journals Online (AJOL)

    Price transmission and market integration: a test of the central market ... cassava production but to improvements in marketing efficiency of the traditional food market ... Improvements in road network and other communication infrastructure will ...

  4. EPICS - MDSplus integration in the ITER Neutral Beam Test Facility

    International Nuclear Information System (INIS)

    Luchetta, Adriano; Manduchi, Gabriele; Barbalace, Antonio; Soppelsa, Anton; Taliercio, Cesare

    2011-01-01

    SPIDER, the ITER-size ion-source test bed in the ITER Neutral Beam Test Facility, is a fusion device requiring a complex central system to provide control and data acquisition, referred to as CODAS. The CODAS software architecture will rely on EPICS and MDSplus, two open-source, collaborative software frameworks, targeted at control and data acquisition, respectively. EPICS has been selected as ITER CODAC middleware and, as the final deliverable of the Neutral Beam Test Facility is the procurement of the ITER Heating Neutral Beam Injector, we decided to adopt this ITER technology. MDSplus is a software package for data management, supporting advanced concepts, such as platform and underlying hardware independence, self description data, and data driven model. The combined use of EPICS and MDSplus is not new in fusion, but their level of integration will be new in SPIDER, achieved by a more refined data access layer. The paper presents the integration software to use effectively EPICS and MDSplus, including the definition of appropriate EPICS records to interact with MDSplus. The MDSplus and EPICS archive concepts are also compared on the basis of performance tests and data streaming is investigated by ad-hoc measurements.

  5. TEST BIAS--VALIDITY OF THE SCHOLASTIC APTITUDE TEST FOR NEGRO AND WHITE STUDENTS IN INTEGRATED COLLEGES.

    Science.gov (United States)

    CLEARY, T. ANNE

    FOR THIS RESEARCH, A TEST WAS SAID TO BE BIASED FOR MEMBERS OF A SUBGROUP OF THE POPULATION IF, IN THE PREDICTION OF A CRITERION FOR WHICH THE TEST WAS DESIGNED, CONSISTENT NONZERO ERRORS OF PREDICTION ARE MADE FOR MEMBERS OF THE SUBGROUP. SAMPLES OF NEGRO AND WHITE STUDENTS FROM THREE INTEGRATED COLLEGES WERE STUDIED. IN THE TWO EASTERN COLLEGES,…

  6. Successful Integration of Hepatitis C Virus Point-of-Care Tests into the Denver Metro Health Clinic

    Directory of Open Access Journals (Sweden)

    A. Jewett

    2013-01-01

    Full Text Available Background. The Centers for Disease Control and Prevention (CDC recommends testing and linkage to care for persons most likely infected with hepatitis C virus (HCV, including persons with human immunodeficiency virus. We explored facilitators and barriers to integrating HCV point-of-care (POC testing into standard operations at an urban STD clinic. Methods. The OraQuick HCV rapid antibody test was integrated at the Denver Metro Health Clinic (DMHC. All clients with at least one risk factor were offered the POC test. Research staff conducted interviews with clients (three HCV positive and nine HCV negative. Focus groups were conducted with triage staff, providers, and linkage-to-care counselors. Results. Clients were pleased with the ease of use and rapid return of results from the HCV POC test. Integrating the test into this setting required more time but was not overly burdensome. While counseling messages were clear to staff, clients retained little knowledge of hepatitis C infection or factors related to risk. Barriers to integrating the HCV POC test into clinic operations were loss to follow-up and access to care. Conclusion. DMHC successfully integrated HCV POC testing and piloted a HCV linkage-to-care program. Providing testing opportunities at STD clinics could increase identification of persons with HCV infection.

  7. Small Payload Launch Integrated Testing Services (SPLITS) - SPSDL

    Science.gov (United States)

    Plotner, Benjamin

    2013-01-01

    My experience working on the Small Payload Launch Integrated Testing Services project has been both educational and rewarding. I have been given the opportunity to work on and experiment with a number of exciting projects and initiatives, each offering different challenges and opportunities for teamwork and collaboration. One of my assignments is to aid in the design and construction of a small-scale two stage rocket as part of a Rocket University initiative. My duties include programming a microcontroller to control the various sensors on the rocket as well as process and transmit data. Additionally, I am writing a graphical user interface application for the ground station that will receive the transmitted data from the rocket and display the information on screen along with a 3D rendering displaying the rocket orientation. Another project I am working on is to design and develop the avionics that will be used to control a high altitude balloon flight that will test a sensor called a Micro Dosimeter that will measure the total ionizing dose absorbed by electrical components during a flight. This includes assembling and soldering the various sensors and components, programming a microcontroller to input and process data from the Micro Dosimeter, and transmitting the data down to a ground station as well as save the data to an on-board SD card. Additionally, I am aiding in the setup and development of ITOS (Integrated Test and Operations System) capability in the SPSDL (Spaceport Processing System Development Lab).

  8. Testing periodically integrated autoregressive models

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); M.J. McAleer (Michael)

    1997-01-01

    textabstractPeriodically integrated time series require a periodic differencing filter to remove the stochastic trend. A non-periodic integrated time series needs the first-difference filter for similar reasons. When the changing seasonal fluctuations for the non-periodic integrated series can be

  9. The scheme optimization and management innovation for the first containment integrated in-service test of nuclear power plant

    International Nuclear Information System (INIS)

    Wang Haiwei; Yang Gang

    2014-01-01

    The containment integrated test is a large-scale, high risk and very difficult test in pressurized water reactor nuclear power plants. By simulating peak pressure inside the containment in DESIGN-BASIS accident conditions, measuring the total leakage rate of the containment with the peak pressure, and implementing the structure inspection test on several pressure levels, the containment's performance can be verified. Containment integrated test is an important witness point supervised by NNSA. The test results crucially decide the reactor to be started or not. The containment integrated test in 301 overhaul is the first in-service test of Unit 3. By the experience of the same 6 former tests in Qinshan Second Nuclear Power Plant and the feedback from other plants, the test scheme get more scientific and the organization management more standardized. This article discusses the containment integrated test in 301 overhaul and summarizes the experience to provide some references for the following containment integrated tests in the future. (authors)

  10. Conceptual design of a fission-based integrated test facility for fusion reactor components

    International Nuclear Information System (INIS)

    Watts, K.D.; Deis, G.A.; Hsu, P.Y.S.; Longhurst, G.R.; Masson, L.S.; Miller, L.G.

    1982-01-01

    The testing of fusion materials and components in fission reactors will become increasingly important because of lack of fusion engineering test devices in the immediate future and the increasing long-term demand for fusion testing when a fusion reactor test station becomes available. This paper presents the conceptual design of a fission-based Integrated Test Facility (ITF) developed by EG and G Idaho. This facility can accommodate entire first wall/blanket (FW/B) test modules such as those proposed for INTOR and can also accommodate smaller cylindrical modules similar to those designed by Oak Ridge National laboratory (ORNL) and Westinghouse. In addition, the facility can be used to test bulk breeder blanket materials, materials for tritium permeation, and components for performance in a nuclear environment. The ITF provides a cyclic neutron/gamma flux as well as the numerous module and experiment support functions required for truly integrated tests

  11. Ontological Analysis of Integrated Process Models: testing hypotheses

    Directory of Open Access Journals (Sweden)

    Michael Rosemann

    2001-11-01

    Full Text Available Integrated process modeling is achieving prominence in helping to document and manage business administration and IT processes in organizations. The ARIS framework is a popular example for a framework of integrated process modeling not least because it underlies the 800 or more reference models embedded in the world's most popular ERP package, SAP R/3. This paper demonstrates the usefulness of the Bunge-Wand-Weber (BWW representation model for evaluating modeling grammars such as those constituting ARIS. It reports some initial insights gained from pilot testing Green and Rosemann's (2000 evaluative propositions. Even when considering all five views of ARIS, modelers have problems representing business rules, the scope and boundary of systems, and decomposing models. However, even though it is completely ontologically redundant, users still find the function view useful in modeling.

  12. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  13. Integration and Testing Challenges of Small, Multiple Satellite Missions: Experiences from the Space Technology 5 Project

    Science.gov (United States)

    Sauerwein, Timothy A.; Gostomski, Thomas

    2008-01-01

    The ST5 technology demonstration mission led by GSFC of NASA's New Millennium Program managed by JPL consisted of three micro satellites (approximately 30 kg each) deployed into orbit from the Pegasus XL launch vehicle. In order to meet the launch date schedule of ST5, a different approach was required rather than the standard I&T approach used for single, room-sized satellites. The three spacecraft were designed, integrated, and tested at NASA Goddard Space Flight Center. It was determined that there was insufficient time in the schedule to perform three spacecraft I&T activities in series using standard approaches. The solution was for spacecraft #1 to undergo integration and test first, followed by spacecraft #2 and #3 simultaneously. This simultaneous integration was successful for several reasons. Each spacecraft had a Lead Test Conductor who planned and coordinated their spacecraft through its integration and test activities. One team of engineers and technicians executed the integration of all three spacecraft, learning and gaining knowledge and efficiency as spacecraft #1 integration and testing progressed. They became acutely familiar with the hardware, operation and processes for I&T, thus had the experience and knowledge to safely execute I&T for spacecraft #2 and #3. The integration team was extremely versatile; each member could perform many different activities or work any spacecraft, when needed. ST5 was successfully integrated, tested and shipped to the launch site per the I&T schedule that was planned three years previously. The I&T campaign was completed with ST5's successful launch on March 22, 2006.

  14. Highly focused ion beams in integrated circuit testing

    International Nuclear Information System (INIS)

    Horn, K.M.; Dodd, P.E.; Doyle, B.L.

    1996-01-01

    The nuclear microprobe has proven to be a useful tool in radiation testing of integrated circuits. This paper reviews single event upset (SEU) and ion beam induced charge collection (IBICC) imaging techniques, with special attention to damage-dependent effects. Comparisons of IBICC measurements with three-dimensional charge transport simulations of charge collection are then presented for isolated p-channel field effect transistors under conducting and non-conducting bias conditions

  15. A Study of Critical Flowrate in the Integral Effect Test Facilities

    International Nuclear Information System (INIS)

    Kim, Yeongsik; Ryu, Sunguk; Cho, Seok; Yi, Sungjae; Park, Hyunsik

    2014-01-01

    In earlier studies, most of the information available in the literature was either for a saturated two-phase flow or a sub-cooled water flow at medium pressure conditions, e. g., up to about 7.0 MPa. The choking is regarded as a condition of maximum possible discharge through a given orifice and/or nozzle exit area. A critical flow rate can be achieved at a choking under the given thermo-hydraulic conditions. The critical flow phenomena were studied extensively in both single-phase and two-phase systems because of its importance in the LOCA analyses of light water reactors and in the design of other engineering areas. Park suggested a modified correlation for predicting the critical flow for sub-cooled water through a nozzle. Recently, Park et al. performed an experimental study on a two-phase critical flow with a noncondensable gas at high pressure conditions. Various experiments of critical flow using sub-cooled water were performed for a modeling of break simulators in thermohydraulic integral effect test facilities for light water reactors, e. g., an advanced power reactor 1400MWe (APR1400) and a system-integrated modular advanced reactor (SMART). For the design of break simulators of SBLOCA scenarios, the aspect ratio (L/D) is considered to be a key parameter to determine the shape of a break simulator. In this paper, an investigation of critical flow phenomena was performed especially on break simulators for LOCA scenarios in the integral effect test facilities of KAERI, such as ATLAS and FESTA. In this study, various studies on the critical flow models for sub-cooled and/or saturated water were reviewed. For a comparison among the models for the selected test data, discussions of the comparisons on the effect of the diameters, predictions of critical flow models, and break simulators for SBLOCA in the integral effect test facilities were presented

  16. A Study of Critical Flowrate in the Integral Effect Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeongsik; Ryu, Sunguk; Cho, Seok; Yi, Sungjae; Park, Hyunsik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In earlier studies, most of the information available in the literature was either for a saturated two-phase flow or a sub-cooled water flow at medium pressure conditions, e. g., up to about 7.0 MPa. The choking is regarded as a condition of maximum possible discharge through a given orifice and/or nozzle exit area. A critical flow rate can be achieved at a choking under the given thermo-hydraulic conditions. The critical flow phenomena were studied extensively in both single-phase and two-phase systems because of its importance in the LOCA analyses of light water reactors and in the design of other engineering areas. Park suggested a modified correlation for predicting the critical flow for sub-cooled water through a nozzle. Recently, Park et al. performed an experimental study on a two-phase critical flow with a noncondensable gas at high pressure conditions. Various experiments of critical flow using sub-cooled water were performed for a modeling of break simulators in thermohydraulic integral effect test facilities for light water reactors, e. g., an advanced power reactor 1400MWe (APR1400) and a system-integrated modular advanced reactor (SMART). For the design of break simulators of SBLOCA scenarios, the aspect ratio (L/D) is considered to be a key parameter to determine the shape of a break simulator. In this paper, an investigation of critical flow phenomena was performed especially on break simulators for LOCA scenarios in the integral effect test facilities of KAERI, such as ATLAS and FESTA. In this study, various studies on the critical flow models for sub-cooled and/or saturated water were reviewed. For a comparison among the models for the selected test data, discussions of the comparisons on the effect of the diameters, predictions of critical flow models, and break simulators for SBLOCA in the integral effect test facilities were presented.

  17. Apparatus and method for defect testing of integrated circuits

    Science.gov (United States)

    Cole, Jr., Edward I.; Soden, Jerry M.

    2000-01-01

    An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.

  18. Testing of interposer-based 2.5D integrated circuits

    CERN Document Server

    Wang, Ran

    2017-01-01

    This book provides readers with an insightful guide to the design, testing and optimization of 2.5D integrated circuits. The authors describe a set of design-for-test methods to address various challenges posed by the new generation of 2.5D ICs, including pre-bond testing of the silicon interposer, at-speed interconnect testing, built-in self-test architecture, extest scheduling, and a programmable method for low-power scan shift in SoC dies. This book covers many testing techniques that have already been used in mainstream semiconductor companies. Readers will benefit from an in-depth look at test-technology solutions that are needed to make 2.5D ICs a reality and commercially viable. Provides a single-source guide to the practical challenges in testing of 2.5D ICs; Presents an efficient method to locate defects in a passive interposer before stacking; Describes an efficient interconnect-test solution to target through-silicon vias (TSVs), the redistribution layer, and micro-bumps for shorts, opens, and dela...

  19. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    Science.gov (United States)

    Yew, Calinda; Whitehouse, Paul; Lui, Yan; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) has completed its system-level testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered for integration with the Optical Telescope Element (OTE) after the successful verification of the system through a series of three cryo-vacuum (CV) tests. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration. The complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. As JWST progressed through its CV testing campaign, deficiencies in the test configuration and support equipment were uncovered from one test to the next. Subsequent upgrades and modifications were implemented to improve the facility support capabilities required to achieve test requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  20. Integrated System Test Approaches for the NASA Ares I Crew Launch Vehicle

    Science.gov (United States)

    Cockrell, Charles

    2008-01-01

    NASA is maturing test and evaluation plans leading to flight readiness of the Ares I crew launch vehicle. Key development, qualification, and verification tests are planned . Upper stage engine sea-level and altitude testing. First stage development and qualification motors. Upper stage structural and thermal development and qualification test articles. Main Propulsion Test Article (MPTA). Upper stage green run testing. Integrated Vehicle Ground Vibration Testing (IVGVT). Aerodynamic characterization testing. Test and evaluation supports initial validation flights (Ares I-Y and Orion 1) and design certification.

  1. Performance tests for integral reactor nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong-Seong; Yim, Jeong-Sik; Lee, Chong-Tak; Kim, Han-Soo; Koo, Yang-Hyun; Lee, Byung-Ho; Cheon, Jin-Sik; Oh, Je-Yong

    2006-02-15

    An integral type reactor SMART plans to utilize metallic Zr-U fuel which is Zr-based alloy with 34{approx}38 wt% U. In order to verify the technologies for the design and manufacturing of the fuel and get a license, performance tests were carried out. Experimental Fuel Assembly (EFA) manufactured in KAERI is being successfully irradiated in the MIR reactor of RIAR from September 4 2004, and it has achieved burnup of 0.21 g/cc as of January 25 2006. Thermal properties of irradiated Zr-U fuel were measured. Up to the phase transformation temperature, thermal diffusivity increased linearly in proportion to temperature. However its dependence on the burnup was not significant. RIA tests with 4 unirradiated Zr-U fuel rods were performed in Kurchatov Institute to establish a safety criterion. In the case of the un-irradiated Zr-U fuel, the energy deposition during the control rod ejection accident should be less than 172 cal/g to prevent the failure accompanying fuel fragmentation and dispersal. Finally the irradiation tests of fuel rods have been performed at HANARO. The HITE-2 test was successfully completed up to a burnup of 0.31 g/cc. The HITE-3 test began in February 2004 and will be continued up to a target burnup of 0.6 g/cc.

  2. Full scale test platform for European TBM systems integration and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz; Reungoat, Mathieu; Vician, Martin

    2016-11-01

    Highlights: • A platform for EU-TBS maintenance and integration tests is described. • Its modular design allows adaptation to non-EU TBSs. • Assembling of the facility will be followed by initial tests in 2016. - Abstract: This article deals with description and current status of a project of a non-nuclear, full size (1:1 scale) test platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER port cell #16. The facility called TBM platform reproduces the ITER port cell #16 and port interspace with all the relevant interfaces and mock-ups of the corresponding main components. Thanks to the modular design of the platform, it is possible to adapt or change completely the interfaces in the future if needed or required according to the updated configuration of TBSs. In the same way, based on customer requirements, it will be possible to adapt the interfaces and piping inside the mock-ups in order to represent also the other, non-EU configurations of TBM systems designed for port cells #02 and #18. Construction of this test platform is realized and funded within the scope of the SUSEN project.

  3. Integration of MSFC Usability Lab with Usability Testing

    Science.gov (United States)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.

  4. RCRA closures at Rocky Flats Plant: A programmatic perspective and case study

    International Nuclear Information System (INIS)

    Ogg, Randy T.; Peterman, Bruce D.

    1992-01-01

    The Interagency Agreement (IAG) integrates a unique mechanism for remediating hazardous waste sites at the Rocky Flats Plant (RFP), which include utilizing RCRA and CERCLA technical/regulatory processes. Pursuant to the IAG signed by the Department of Energy (DOE), Environmental Protection Agency (EPA), and the Colorado Department of Health (CDH) on January 22, 1991, sixteen operable units (OUs) were defined for characterization and remediation at RFP. Of the sixteen OUs, six are classified as Resource Conservation and Recovery Act (RCRA) closure units. The six RCRA interim status closure units are: Solar Evaporation Ponds-OU 4, Present LandfUl-OU 7, Original Process Waste Lines-OU 9, Other Outside Closures-OU 10, West Spray Field-OU II, and Inside Building Closures-OU 15. The IAG will function as a technical/regulatory mechanism for managing/complying with all aspects of the RCRA interim status closure units at RFP. (author)

  5. Integrated, digital experiment transient control and safety protection of an in-pile test

    International Nuclear Information System (INIS)

    Thomas, R.W.; Whitacre, R.F.; Klingler, W.B.

    1982-01-01

    The Sodium Loop Safety Facility experimental program has demonstrated that in-pile loop fuel failure transient tests can be digitally controlled and protected with reliability and precision. This was done in four nuclear experiments conducted in the Engineering Test Reactor operated by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Loop sodium flow and reactor power transients can be programmed to sponsor requirements and verified prior to the test. Each controller has redundancy, which reduces the effect of single failures occurring during test transients. Feedback and reject criteria are included in the reactor power control. Timed sequencing integrates the initiation of the controllers, programmed safety set-points, and other experiment actions (e.g., planned scram). Off-line and on-line testing is included. Loss-of-flow, loss-of-piping-integrity, boiling-window, transient-overpower, and local fault tests have been successfully run using this system

  6. BWR Full Integral Simulation Test (FIST) program: facility description report

    International Nuclear Information System (INIS)

    Stephens, A.G.

    1984-09-01

    A new boiling water reactor safety test facility (FIST, Full Integral Simulation Test) is described. It will be used to investigate small breaks and operational transients and to tie results from such tests to earlier large-break test results determined in the TLTA. The new facility's full height and prototypical components constitute a major scaling improvement over earlier test facilities. A heated feedwater system, permitting steady-state operation, and a large increase in the number of measurements are other significant improvements. The program background is outlined and program objectives defined. The design basis is presented together with a detailed, complete description of the facility and measurements to be made. An extensive component scaling analysis and prediction of performance are presented

  7. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  8. Electrical Integrity Tests during Production of the LHC Dipoles

    CERN Document Server

    de Rijk, G; Cornelis, M; Fessia, P; Miles, J; Modena, M; Molinari, G; Rinn, J; Savary, F; Vlogaert, J

    2006-01-01

    For the LHC dipoles, mandatory electrical integrity tests are performed to qualify the cold mass (CM) at four production stages: individual pole, collared coil, CM before end cover welding and final CM. A description of the measurement equipment and its recent development are presented. After passing the demands set out in the specification, the results of the tests are transmitted to CERN where they are further analyzed. The paper presents the most important results of these measurements. We also report a review of the electrical non-conformities encountered e.g. interturn shorts and quench heater failure, their diagnostic and the cures.

  9. PANDA: A Multipurpose Integral Test Facility for LWR Safety Investigations

    International Nuclear Information System (INIS)

    Paladino, D.; Dreier, J.

    2012-01-01

    The PANDA facility is a large scale, multicompartmental thermal hydraulic facility suited for investigations related to the safety of current and advanced LWRs. The facility is multipurpose, and the applications cover integral containment response tests, component tests, primary system tests, and separate effect tests. Experimental investigations carried on in the PANDA facility have been embedded in international projects, most of which under the auspices of the EU and OECD and with the support of a large number of organizations (regulatory bodies, technical dupport organizations, national laboratories, electric utilities, industries) worldwide. The paper provides an overview of the research programs performed in the PANDA facility in relation to BWR containment systems and those planned for PWR containment systems.

  10. System engineering approach in the EU Test Blanket Systems Design Integration

    International Nuclear Information System (INIS)

    Panayotov, D.; Sardain, P.; Boccaccini, L.V.; Salavy, J.-F.; Cismondi, F.; Jourd'Heuil, L.

    2011-01-01

    The complexity of the Test Blanket Systems demands diverse and comprehensive integration activities. Test Blanket Modules - Consortia of Associates (TBM-CA) applies the system engineering methods in all stages of the Test Blanket System (TBS) design integration. Completed so far integration engineering tasks cover among others status and initial set of TBS operating parameters; list of codes, standards and regulations related to TBS; planning of the TBS interfaces and baseline documentation. Most of the attention is devoted to the establishment the Helium-Cooled Lithium Lead (HCLL) and Helium-Cooled Pebble Bed Lead (HCPB) TBS configuration baseline, TBS break down into sub-systems, identification, definition and management of the internal and external interfaces, development of the TBS plant break down structure (PBS), establishment and management of the required TBS baseline documentation infrastructure. Break down of the TBS into sub-systems that is crucial for the further design and interfaces' management has been selected considering several options and using specific evaluation criteria. Process of the TBS interfaces management covers the planning, definition and description, verification and review, non-conformances and deviations, and modification and improvement processes. Process of interfaces review is developed, identifying the actors, input, activities and output of the review. Finally the relations and interactions of system engineering processes with TBM configuration management and TBM-CA Quality Management System are discussed.

  11. Integrative set enrichment testing for multiple omics platforms

    Directory of Open Access Journals (Sweden)

    Poisson Laila M

    2011-11-01

    Full Text Available Abstract Background Enrichment testing assesses the overall evidence of differential expression behavior of the elements within a defined set. When we have measured many molecular aspects, e.g. gene expression, metabolites, proteins, it is desirable to assess their differential tendencies jointly across platforms using an integrated set enrichment test. In this work we explore the properties of several methods for performing a combined enrichment test using gene expression and metabolomics as the motivating platforms. Results Using two simulation models we explored the properties of several enrichment methods including two novel methods: the logistic regression 2-degree of freedom Wald test and the 2-dimensional permutation p-value for the sum-of-squared statistics test. In relation to their univariate counterparts we find that the joint tests can improve our ability to detect results that are marginal univariately. We also find that joint tests improve the ranking of associated pathways compared to their univariate counterparts. However, there is a risk of Type I error inflation with some methods and self-contained methods lose specificity when the sets are not representative of underlying association. Conclusions In this work we show that consideration of data from multiple platforms, in conjunction with summarization via a priori pathway information, leads to increased power in detection of genomic associations with phenotypes.

  12. The Verification of ESF-CCS Integration Test procedure by utilizing Lab view

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jayoung; Lee, Sangseok; Sohn, Kwangyoung [Korea Reliability Technology and System, Daejeon (Korea, Republic of); Lee, Junku; Park, Geunok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    Since the Fukushima event, especially it is considered to be important to guarantee the safety of plant by mitigating the major accident. ESF-CCS (Engineered Safety Feature-Component Control System) is monitoring all the plant variables and generates the ESF-CCS actuation signals when the plant variables violate the setpoint. Taking a look at the classic design, ESF-CCS is composed of the sub-components such as Minimum Inventory (MI), ESCM (ESF-CCS Soft Control Module), CPM, ITP, Group Controller (GC), Loop Controller (LC), CCG (Control Channel Gate), MTP, CIM (Component Interface Module). By help of Lab view simulation in integration test procedure preparation, the following benefits are attained; - Control logic and design evaluation by Lab view - Eliminating the time-consuming test case design, and determining the 'expected result' with design validation - The reliability upgrade of integration test quality.

  13. Commissioning of an Integral Effect Test Loop for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyunsik; Bae, Hwang; Kim, Dongeok; Min, Kyoungho; Shin, Yongcheol; Ko, Yungjoo; Yi, Sungjae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    An integral-effect test loop for SMART, SMART-ITL (or FESTA), has been constructed at KAERI. Its height was preserved and its flow area and volume were scaled down to 1/49 compared with the prototype plant, SMART. The ratio of the hydraulic diameter is 1/7. The SMART is a 330 MW thermal power reactor, and its core exit temperature and PZR pressure are 323 .deg. C and 15 MPa during a normal working condition, respectively. The maximum power of the core heater in the SMART-ITL is 30% of the scaled full power. As shown in Fig. 1, the SMART-ITL consists of a primary system including a reactor pressure vessel with a pressurizer, four steam generators and four main coolant pumps, a secondary system, a safety system, and an auxiliary system. The SMART-ITL facility will be used to investigate the integral performance of the inter-connected components and possible thermal-hydraulic phenomena occurring in the SMART design, to validate its safety for various design basis events and broad transient scenarios, and to validate the related thermal-hydraulic models of the safety analysis codes. The scenarios include small-break loss-of coolant accident (SBLOCA) scenarios, complete loss of RCS flowrate (CLOF), steam generator tube rupture (SGTR), feedwater line break (FLB), and main steam line break (MSLB). The role of SMART-ITL will be extended to examine and verify the normal, abnormal, and emergency operating procedures required during the construction and export phases of SMART. After an extensive series of commissioning tests in 2012, the SMART-ITL facility is now in operation. In this paper, the major test results acquired during the commissioning tests will be discussed.

  14. Integrated testing strategy (ITS) for bioaccumulation assessment under REACH

    DEFF Research Database (Denmark)

    Lombardo, Anna; Roncaglioni, Alessandra; Benfentati, Emilio

    2014-01-01

    in a dossier. REACH promotes the use of alternative methods to replace, refine and reduce the use of animal (eco)toxicity testing. Within the EU OSIRIS project, integrated testing strategies (ITSs) have been developed for the rational use of non-animal testing approaches in chemical hazard assessment. Here we......REACH (registration, evaluation, authorisation and restriction of chemicals) regulation requires that all the chemicals produced or imported in Europe above 1 tonne/year are registered. To register a chemical, physicochemical, toxicological and ecotoxicological information needs to be reported...... present an ITS for evaluating the bioaccumulation potential of organic chemicals. The scheme includes the use of all available data (also the non-optimal ones), waiving schemes, analysis of physicochemical properties related to the end point and alternative methods (both in silico and in vitro). In vivo...

  15. Vehicle Testing and Integration Facility; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-02

    Engineers at the National Renewable Energy Laboratory’s (NREL’s) Vehicle Testing and Integration Facility (VTIF) are developing strategies to address two separate but equally crucial areas of research: meeting the demands of electric vehicle (EV) grid integration and minimizing fuel consumption related to vehicle climate control. Dedicated to renewable and energy-efficient solutions, the VTIF showcases technologies and systems designed to increase the viability of sustainably powered vehicles. NREL researchers instrument every class of on-road vehicle, conduct hardware and software validation for EV components and accessories, and develop analysis tools and technology for the Department of Energy, other government agencies, and industry partners.

  16. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  17. Static and dynamic pile testing of reinforced concrete piles with structure integrated fibre optic strain sensors

    Science.gov (United States)

    Schilder, Constanze; Kohlhoff, Harald; Hofmann, Detlef; Basedau, Frank; Habel, Wolfgang R.; Baeßler, Matthias; Niederleithinger, Ernst; Georgi, Steven; Herten, Markus

    2013-05-01

    Static and dynamic pile tests are carried out to determine the load bearing capacity and the quality of reinforced concrete piles. As part of a round robin test to evaluate dynamic load tests, structure integrated fibre optic strain sensors were used to receive more detailed information about the strains along the pile length compared to conventional measurements at the pile head. This paper shows the instrumentation of the pile with extrinsic Fabry-Perot interferometers sensors and fibre Bragg gratings sensors together with the results of the conducted static load test as well as the dynamic load tests and pile integrity tests.

  18. Integrated water management system - Description and test results. [for Space Station waste water processing

    Science.gov (United States)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  19. Testing Predictive Models of Technology Integration in Mexico and the United States

    Science.gov (United States)

    Velazquez, Cesareo Morales

    2008-01-01

    Data from Mexico City, Mexico (N = 978) and from Texas, USA (N = 932) were used to test the predictive validity of the teacher professional development component of the Will, Skill, Tool Model of Technology Integration in a cross-cultural context. Structural equation modeling (SEM) was used to test the model. Analyses of these data yielded…

  20. Hot-Fire Test Results of an Oxygen/RP-2 Multi-Element Oxidizer-Rich Staged-Combustion Integrated Test Article

    Science.gov (United States)

    Hulka, J. R.; Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. For the thrust chamber assembly of the test article, several configurations of new main injectors, using relatively conventional gas-centered swirl coaxial injector elements, were designed and fabricated. The design and fabrication of these main injectors are described in a companion paper at this JANNAF meeting. New ablative combustion chambers were fabricated based on hardware previously used at NASA for testing at similar size and pressure. An existing oxygen/RP-1 oxidizer-rich subscale preburner injector from a previous NASA-funded program, along with existing and new inter-connecting hot gas duct hardware, were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. Results from independent hot-fire tests of the preburner injector in a combustion chamber with a sonic throat are described in companion papers at this JANNAF conference. The resulting integrated test article - which includes the preburner, inter-connecting hot gas duct, main injector, and ablative combustion chamber - was assembled at Test Stand 116 at the East Test Area of the NASA Marshall Space Flight Center. The test article was well instrumented with static and dynamic pressure, temperature, and acceleration sensors to allow the collected data to be used for

  1. Integral test of JENDL-3.3 for fast reactors

    International Nuclear Information System (INIS)

    Chiba, Gou

    2003-01-01

    An integral test of JENDL-3.3 was performed for fast reactors. Various types of fast reactors were analyzed. Calculation values of the nuclear characteristics were greatly especially affected by the revisions of the cross sections of U-235 capture and elastic scattering reactions. The C/E values were improved for ZPPR cross where plutonium is mainly fueled, but not for BFS cores where uranium is mainly fueled. (author)

  2. Counter-part Test and Code Analysis of the Integral Test Loop, SNUF

    International Nuclear Information System (INIS)

    Park, Goon Cherl; Bae, B. U.; Lee, K. H.; Cho, Y. J.

    2007-02-01

    The thermal-hydraulic phenomena of Direct Vessel Injection (DVI) line Small-Break Loss-of-Coolant Accident (SBLOCA) in pressurized water reactor, APR1400, were investigated. The reduced-height and reduced-pressure integral test loop, SNUF (Seoul National University Facility), was constructed with scaling down the prototype. For the appropriate test conditions in the experiment of SNUF, the energy scaling methodology was suggested as scaling the coolant mass inventory and thermal power for the reduced-pressure condition. From the MARS code analysis, the energy scaling methodology was confirmed to show the reasonable transient when ideally scaled-down SNUF model was compared to the prototype model. In the experiments according to the conditions determined by energy scaling methodology, the phenomenon of downcomer seal clearing had a dominant role in decrease of the system pressure and increase of the coolant level of core. The experimental results was utilized to validate the calculation capability of MARS

  3. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    OpenAIRE

    Hwang Bae; Dong Eok Kim; Sung-Uk Ryu; Sung-Jae Yi; Hyun-Sik Park

    2017-01-01

    Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are s...

  4. IFMIF target and test cell - design and integration

    International Nuclear Information System (INIS)

    Heinzel, V.

    2007-01-01

    The International Fusion Material Irradiation Facility (IFMIF) aims at the qualification of appropriate materials for a Demonstration Fusion Power Plant (DEMO) to a fluence of up to 150 dpa (displacement per atom) at a DEMO typical neutron spectrum. It comprises two accelerators each providing a deuteron beam with 125 mA and 40 MeV. The deuterons strike a lithium target and create via stripping reactions neutrons. The neutrons are mainly forward directed into the High-Flux-Test-Module (HFTM). The Medium Flux-Test-Modules (MFTM) and the Low-Flux-Test-Modules (LFTM) are arranged in beam direction behind. In the HFTM a damage rate in steel of more than 20 dpa/fpy (displacement per atome per full power year) will be provide in a volume of 0.5 litre. The neutron spectrum is prone to produce helium and tritium in steel like in the first wall of a DEMO reactor. The Medium- Flux-Test-Modules are designed for creep fatigues in situ and tritium release test. The test modules are cooled with helium. The target is a lithium jet with a free surface towards the deuteron beams. The jet follows a concave curved so called back wall. Centrifugal forces increase the static pressure, which prevents lithium boiling at the beam tube pressure and the power release of 10 MW due to the deuteron beams. The target and Test Cell (TTC) houses the target and the test modules as well as the lithium supply tubes and a quench tank into which the lithium splashes after the target. The lithium containing components have a temperature of 250 to 350 C. Nuclear reactions mainly in beam direction contribute to heat releases in TTC components. The TTC is filled with a noble gas with almost atmospheric pressure. Natural convection transfers heat to the walls but also mitigates temperature peaks. The Forschungszentrum Karlsruhe (FZK) has developed or validated tools for: - The extended Monte Carlo Code McDeLicious for calculations of the neutron source term, dpa rates in the material specimens, activation

  5. Computer simulation of thermal and fluid systems for MIUS integration and subsystems test /MIST/ laboratory. [Modular Integrated Utility System

    Science.gov (United States)

    Rochelle, W. C.; Liu, D. K.; Nunnery, W. J., Jr.; Brandli, A. E.

    1975-01-01

    This paper describes the application of the SINDA (systems improved numerical differencing analyzer) computer program to simulate the operation of the NASA/JSC MIUS integration and subsystems test (MIST) laboratory. The MIST laboratory is designed to test the integration capability of the following subsystems of a modular integrated utility system (MIUS): (1) electric power generation, (2) space heating and cooling, (3) solid waste disposal, (4) potable water supply, and (5) waste water treatment. The SINDA/MIST computer model is designed to simulate the response of these subsystems to externally impressed loads. The computer model determines the amount of recovered waste heat from the prime mover exhaust, water jacket and oil/aftercooler and from the incinerator. This recovered waste heat is used in the model to heat potable water, for space heating, absorption air conditioning, waste water sterilization, and to provide for thermal storage. The details of the thermal and fluid simulation of MIST including the system configuration, modes of operation modeled, SINDA model characteristics and the results of several analyses are described.

  6. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  7. Non-destructive testing and evaluation for structural integrity

    International Nuclear Information System (INIS)

    Baldev Raj; Jayakumar, T.; Rao, B.P.C.

    1995-01-01

    In this paper, a brief description of the physical concepts of non-destructive evaluation (NDE) methods and the physical/derived parameters that are used for assessing defects, stresses and microstructures are given. A few case studies highlighting the importance of non-destructive testing and evaluation for structural integrity assessment are also discussed based on the investigations carried out. Emerging concepts like intelligent processing of materials, expert systems, neural networks, use of multisensors with fusion of data and exploitation of signal analysis and imaging approaches are also addressed in this paper. (author). 92 refs., 1 tab

  8. Fuel motion in overpower tests of metallic integral fast reactor fuel

    International Nuclear Information System (INIS)

    Rhodes, E.A.; Bauer, T.H.; Stanford, G.S.; Regis, J.P.; Dickerman, C.E.

    1992-01-01

    In this paper results from hodoscope data analyses are presented for transient overpower (TOP) tests M5, M6, and M7 at the Transient Reactor Test Facility, with emphasis on transient feedback mechanisms, including prefailure expansion at the tops of the fuel pins, subsequent dispersive axial fuel motion, and losses in relative worth of the fuel pins during the tests. Tests M5 and M6 were the first TOP tests of margin to cladding breach and prefailure elongation of D9-clad ternary (U-Pu-Zr) integral fast reactor-type fuel. Test M7 extended these results to high-burnup fuel and also initiated transient testing of HT-9-clad binary (U-Zr) Fast Flux Test Facility driver fuel. Results show significant prefailure negative reactivity feedback and strongly negative feedback from fuel driven to failure

  9. Integrated testing strategies can be optimal for chemical risk classification.

    Science.gov (United States)

    Raseta, Marko; Pitchford, Jon; Cussens, James; Doe, John

    2017-08-01

    There is an urgent need to refine strategies for testing the safety of chemical compounds. This need arises both from the financial and ethical costs of animal tests, but also from the opportunities presented by new in-vitro and in-silico alternatives. Here we explore the mathematical theory underpinning the formulation of optimal testing strategies in toxicology. We show how the costs and imprecisions of the various tests, and the variability in exposures and responses of individuals, can be assembled rationally to form a Markov Decision Problem. We compute the corresponding optimal policies using well developed theory based on Dynamic Programming, thereby identifying and overcoming some methodological and logical inconsistencies which may exist in the current toxicological testing. By illustrating our methods for two simple but readily generalisable examples we show how so-called integrated testing strategies, where information of different precisions from different sources is combined and where different initial test outcomes lead to different sets of future tests, can arise naturally as optimal policies. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Testing an integral conceptual model of frailty.

    Science.gov (United States)

    Gobbens, Robbert J; van Assen, Marcel A; Luijkx, Katrien G; Schols, Jos M

    2012-09-01

    This paper is a report of a study conducted to test three hypotheses derived from an integral conceptual model of frailty.   The integral model of frailty describes the pathway from life-course determinants to frailty to adverse outcomes. The model assumes that life-course determinants and the three domains of frailty (physical, psychological, social) affect adverse outcomes, the effect of disease(s) on adverse outcomes is mediated by frailty, and the effect of frailty on adverse outcomes depends on the life-course determinants. In June 2008 a questionnaire was sent to a sample of community-dwelling people, aged 75 years and older (n = 213). Life-course determinants and frailty were assessed using the Tilburg frailty indicator. Adverse outcomes were measured using the Groningen activity restriction scale, the WHOQOL-BREF and questions regarding healthcare utilization. The effect of seven self-reported chronic diseases was examined. Life-course determinants, chronic disease(s), and frailty together explain a moderate to large part of the variance of the seven continuous adverse outcomes (26-57%). All these predictors together explained a significant part of each of the five dichotomous adverse outcomes. The effect of chronic disease(s) on all 12 adverse outcomes was mediated at least partly by frailty. The effect of frailty domains on adverse outcomes did not depend on life-course determinants. Our finding that the adverse outcomes are differently and uniquely affected by the three domains of frailty (physical, psychological, social), and life-course determinants and disease(s), emphasizes the importance of an integral conceptual model of frailty. © 2011 Blackwell Publishing Ltd.

  11. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  12. Sodium tests on an integrated purification prototype for a sodium-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Abramson, R.

    1984-04-01

    This paper describes sodium tests performed on the integrated primary sodium purification prototype of the Creys Malville Super Phenix 1 fast breeder reactor. These tests comprised: - hydrostatic test, - thermal tests, - handling tests. They enabled a number of new technological arrangements to be qualified and provided the necessary information for the design and construction of the Super Phenix 1 purification units

  13. Computer-aided-engineering system for modeling and analysis of ECLSS integration testing

    Science.gov (United States)

    Sepahban, Sonbol

    1987-01-01

    The accurate modeling and analysis of two-phase fluid networks found in environmental control and life support systems is presently undertaken by computer-aided engineering (CAE) techniques whose generalized fluid dynamics package can solve arbitrary flow networks. The CAE system for integrated test bed modeling and analysis will also furnish interfaces and subsystem/test-article mathematical models. Three-dimensional diagrams of the test bed are generated by the system after performing the requisite simulation and analysis.

  14. Functional imaging in bulk tissue specimens using optical emission tomography: fluorescence preservation during optical clearing

    International Nuclear Information System (INIS)

    Sakhalkar, H S; Dewhirst, M; Oliver, T; Cao, Y; Oldham, M

    2007-01-01

    Optical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can be imaged by (i) systemic application of functional labels (e.g. fluorophore labelled proteins) and/or (ii) endogenous expression of fluorescent reporter proteins (e.g. red fluorescent protein (RFP), green fluorescent protein (GFP)) in vivo. An essential prerequisite for optical-ECT is optical clearing, a procedure where tissue specimens are made transparent to light by sequential perfusion with fixing, dehydrating and clearing agents. In this study, we investigate clearing protocols involving a selection of common fixing (4% buffered paraformaldehyde (PFA), methanol and ethanol), dehydrating (methanol and ethanol) and clearing agents (methyl salicylate and benzyl-alcohol-benzyl-benzoate (BABB)) in order to determine a 'fluorescence friendly' clearing procedure. Cell culture experiments were employed to optimize the sequence of chemical treatments that best preserve fluorescence. Texas red (TxRed), fluorescein isothiocyanate (FITC), RFP and GFP were tested as fluorophores and fluorescent reporter proteins of interest. Fluorescent and control cells were imaged on a microscope using a DSred2 and FITC filter set. The most promising clearing protocols of cell culture experiments were applied to whole xenograft tumour specimens, to test their effectiveness in large unsectioned samples. Fluorescence of TxRed/FITC fluorophores was not found to be significantly affected by any of the test clearing protocols. RFP and GFP fluorescence, however, was found to be significantly greater when cell fixation was in ethanol. Fixation in either PFA or methanol resulted in diminished fluorescence. After ethanol fixation, the RFP and GFP fluorescence proved remarkably robust to subsequent exposure to either methyl salicylate or BABB

  15. Functional imaging in bulk tissue specimens using optical emission tomography: fluorescence preservation during optical clearing

    Energy Technology Data Exchange (ETDEWEB)

    Sakhalkar, H S [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Dewhirst, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Oliver, T [Department of Cell Biology, Duke University Medical Center, Durham, NC 27710 (United States); Cao, Y [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Oldham, M [Department of Radiation Oncology Physics, and Biomedical Engineering, Duke University Medical Center, Durham, NC 27710 (United States)

    2007-04-21

    Optical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can be imaged by (i) systemic application of functional labels (e.g. fluorophore labelled proteins) and/or (ii) endogenous expression of fluorescent reporter proteins (e.g. red fluorescent protein (RFP), green fluorescent protein (GFP)) in vivo. An essential prerequisite for optical-ECT is optical clearing, a procedure where tissue specimens are made transparent to light by sequential perfusion with fixing, dehydrating and clearing agents. In this study, we investigate clearing protocols involving a selection of common fixing (4% buffered paraformaldehyde (PFA), methanol and ethanol), dehydrating (methanol and ethanol) and clearing agents (methyl salicylate and benzyl-alcohol-benzyl-benzoate (BABB)) in order to determine a 'fluorescence friendly' clearing procedure. Cell culture experiments were employed to optimize the sequence of chemical treatments that best preserve fluorescence. Texas red (TxRed), fluorescein isothiocyanate (FITC), RFP and GFP were tested as fluorophores and fluorescent reporter proteins of interest. Fluorescent and control cells were imaged on a microscope using a DSred2 and FITC filter set. The most promising clearing protocols of cell culture experiments were applied to whole xenograft tumour specimens, to test their effectiveness in large unsectioned samples. Fluorescence of TxRed/FITC fluorophores was not found to be significantly affected by any of the test clearing protocols. RFP and GFP fluorescence, however, was found to be significantly greater when cell fixation was in ethanol. Fixation in either PFA or methanol resulted in diminished fluorescence. After ethanol fixation, the RFP and GFP fluorescence proved remarkably robust to subsequent exposure to either methyl salicylate

  16. Effectiveness of test driven development and continuous integration - a case study

    NARCIS (Netherlands)

    Amrit, Chintan; Meijberg, Yoni

    2018-01-01

    In this article we describe the implementation of hybrid agile practices, namely Test Driven Development (TDD) and Continuous Integration (CI) at a Dutch SME. The quality and productivity outcomes of the case study were compared to a performance baseline set by a reference case, a preceding

  17. Cryo-Vacuum Testing of the Integrated Science Instrument Module for the James Webb Space Telescope

    Science.gov (United States)

    Kimble, Randy A.; Davila, P. S.; Drury, M. P.; Glazer, S. D.; Krom, J. R.; Lundquist, R. A.; Mann, S. D.; McGuffey, D. B.; Perry, R. L.; Ramey, D. D.

    2011-01-01

    With delivery of the science instruments for the James Webb Space Telescope (JWST) to Goddard Space Flight Center (GSFC) expected in 2012, current plans call for the first cryo-vacuum test of the Integrated Science Instrument Module (ISIM) to be carried out at GSFC in early 2013. Plans are well underway for conducting this ambitious test, which will perform critical verifications of a number of optical, thermal, and operational requirements of the IS 1M hardware, at its deep cryogenic operating temperature. We describe here the facilities, goals, methods, and timeline for this important Integration & Test milestone in the JWST program.

  18. Introduction to Large-sized Test Facility for validating Containment Integrity under Severe Accidents

    International Nuclear Information System (INIS)

    Na, Young Su; Hong, Seongwan; Hong, Seongho; Min, Beongtae

    2014-01-01

    An overall assessment of containment integrity can be conducted properly by examining the hydrogen behavior in the containment building. Under severe accidents, an amount of hydrogen gases can be generated by metal oxidation and corium-concrete interaction. Hydrogen behavior in the containment building strongly depends on complicated thermal hydraulic conditions with mixed gases and steam. The performance of a PAR can be directly affected by the thermal hydraulic conditions, steam contents, gas mixture behavior and aerosol characteristics, as well as the operation of other engineering safety systems such as a spray. The models in computer codes for a severe accident assessment can be validated based on the experiment results in a large-sized test facility. The Korea Atomic Energy Research Institute (KAERI) is now preparing a large-sized test facility to examine in detail the safety issues related with hydrogen including the performance of safety devices such as a PAR in various severe accident situations. This paper introduces the KAERI test facility for validating the containment integrity under severe accidents. To validate the containment integrity, a large-sized test facility is necessary for simulating complicated phenomena induced by an amount of steam and gases, especially hydrogen released into the containment building under severe accidents. A pressure vessel 9.5 m in height and 3.4 m in diameter was designed at the KAERI test facility for the validating containment integrity, which was based on the THAI test facility with the experimental safety and the reliable measurement systems certified for a long time. This large-sized pressure vessel operated in steam and iodine as a corrosive agent was made by stainless steel 316L because of corrosion resistance for a long operating time, and a vessel was installed in at KAERI in March 2014. In the future, the control systems for temperature and pressure in a vessel will be constructed, and the measurement system

  19. Stripline kicker for integrable optics test accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, Sergey A.; Didenko, Alexander; Lebedev, Valeri; Valishev, Alexander

    2016-06-30

    We present a design of a stripline kicker for Integrable Optics Test Accelerator (IOTA). For its experimental program IOTA needs two full-aperture kickers, capable to create an arbitrary controllable kick in 2D. For that reason their strengths are variable in a wide range of amplitudes up to 16 mrad, and the pulse length 100 ns is less than a revolution period for electrons. In addition, the kicker should have a physical aperture of 40 mm for a proposed operation with proton beam, and an outer size of 70 mm to fit inside existing quadrupole magnets to save space in the ring. Computer simulations using CST Microwave Studio show high field uniformity and wave impedance close to 50 {\\Omega}.

  20. Towards Intelligent Interpretation of Low Strain Pile Integrity Testing Results Using Machine Learning Techniques.

    Science.gov (United States)

    Cui, De-Mi; Yan, Weizhong; Wang, Xiao-Quan; Lu, Lie-Min

    2017-10-25

    Low strain pile integrity testing (LSPIT), due to its simplicity and low cost, is one of the most popular NDE methods used in pile foundation construction. While performing LSPIT in the field is generally quite simple and quick, determining the integrity of the test piles by analyzing and interpreting the test signals (reflectograms) is still a manual process performed by experienced experts only. For foundation construction sites where the number of piles to be tested is large, it may take days before the expert can complete interpreting all of the piles and delivering the integrity assessment report. Techniques that can automate test signal interpretation, thus shortening the LSPIT's turnaround time, are of great business value and are in great need. Motivated by this need, in this paper, we develop a computer-aided reflectogram interpretation (CARI) methodology that can interpret a large number of LSPIT signals quickly and consistently. The methodology, built on advanced signal processing and machine learning technologies, can be used to assist the experts in performing both qualitative and quantitative interpretation of LSPIT signals. Specifically, the methodology can ease experts' interpretation burden by screening all test piles quickly and identifying a small number of suspected piles for experts to perform manual, in-depth interpretation. We demonstrate the methodology's effectiveness using the LSPIT signals collected from a number of real-world pile construction sites. The proposed methodology can potentially enhance LSPIT and make it even more efficient and effective in quality control of deep foundation construction.

  1. Coupled hydrodynamic-structural analysis of an integral flowing sodium test loop in the TREAT reactor

    International Nuclear Information System (INIS)

    Zeuch, W.R.; A-Moneim, M.T.

    1979-01-01

    A hydrodynamic-structural response analysis of the Mark-IICB loop was performed for the TREAT (Transient Reactor Test Facility) test AX-1. Test AX-1 is intended to provide information concerning the potential for a vapor explosion in an advanced-fueled LMFBR. The test will be conducted in TREAT with unirradiated uranium-carbide fuel pins in the Mark-IICB integral flowing sodium loop. Our analysis addressed the ability of the experimental hardware to maintain its containment integrity during the reference accident postulated for the test. Based on a thermal-hydraulics analysis and assumptions for fuel-coolant interaction in the test section, a pressure pulse of 144 MPa maximum pressure and pulse width of 1.32 ms has been calculated as the reference accident. The response of the test loop to the pressure transient was obtained with the ICEPEL and STRAW codes. Modelling of the test section was completed with STRAW and the remainder of the loop was modelled by ICEPEL

  2. Enhanced rifampicin delivery to alveolar macrophages by solid lipid nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Chuan Junlan [West China School of Pharmacy, Sichuan University, Key Laboratory of Drug Targeting and Drug Delivery System, Ministry of Education (China); Li Yanzhen [Tianjin Institute of Pharmaceutical Research, State Key Laboratory of Drug Delivery Technology and Pharmacokinetics (China); Yang Likai; Sun Xun [West China School of Pharmacy, Sichuan University, Key Laboratory of Drug Targeting and Drug Delivery System, Ministry of Education (China); Zhang Qiang [Peking University, State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences (China); Gong Tao, E-mail: gongtaoy@126.com; Zhang Zhirong, E-mail: zrzzl@vip.sina.com [West China School of Pharmacy, Sichuan University, Key Laboratory of Drug Targeting and Drug Delivery System, Ministry of Education (China)

    2013-05-15

    The present study aimed at developing a drug delivery system targeting the densest site of tuberculosis infection, the alveolar macrophages (AMs). Rifampicin (RFP)-loaded solid lipid nanoparticles (RFP-SLNs) with an average size of 829.6 {+-} 16.1 nm were prepared by a modified lipid film hydration method. The cytotoxicity of RFP-SLNs to AMs and alveolar epithelial type II cells (AECs) was examined using MTT assays. The viability of AMs and AECs was above 80 % after treatment with RFP-SLNs, which showed low toxicity to both AMs and AECs. Confocal Laser Scanning Microscopy was employed to observe the interaction between RFP-SLNs and both AMs and AECs. After incubating the cells with RFP-SLNs for 2 h, the fluorescent intensity in AMs was more and remained longer (from 0.5 to 12 h) when compared with that in AECs (from 0.5 to 8 h). In vitro uptake characteristics of RFP-SLNs in AMs and AECs were also investigated by detection of intracellular RFP by High performance liquid chromatography. Results showed that RFP-SLNs delivered markedly higher RFP into AMs (691.7 ng/mg in cultured AMs, 662.6 ng/mg in primary AMs) than that into AECs (319.2 ng/mg in cultured AECs, 287.2 ng/mg in primary AECs). Subsequently, in vivo delivery efficiency and the selectivity of RFP-SLNs were further verified in Sprague-Dawley rats. Under pulmonary administration of RFP-SLNs, the amount of RFP in AMs was significantly higher than that in AECs at each time point. Our results demonstrated that solid lipid nanoparticles are a promising strategy for the delivery of rifampicin to alveolar macrophages selectively.

  3. Unit and integration testing of Lustre programs: a case study from the nuclear industry

    International Nuclear Information System (INIS)

    Thevenod-Fosse, P.

    1998-01-01

    LUSTRE belongs to the class of synchronous data flow languages which have been designed for programming reactive and real-time systems having safety-critical requirements. It is implemented in the SCADE tool. SCADE is a software development environment for real-time systems which consists of a graphical and textual editor, and a C code generator. In previous work, a testing approach specific to LUSTRE programs has been defined, which may be applied at either the unit or integration testing levels of a gradual testing process. The paper reports on an industrial case study we have performed to exemplify the feasibility of the testing strategy. The software module, called SRIC (Source Range Instrumentation channel), was developed by SCHNEIDER ELECTRIC in the SCADE environment. SRIC is extracted from a monitoring software system of a nuclear reactor: it approximates 2600 lines of C code automatically generated by SCADE. Section 2 outlines the testing strategy. Then, Section 3 presents the results related to the program SRIC, for which four testing levels were defined (unit testing followed by three successive integration testing levels). First conclusions and direction for future work are proposed in Section 4. (author)

  4. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  5. Properties Important To Mixing For WTP Large Scale Integrated Testing

    International Nuclear Information System (INIS)

    Koopman, D.; Martino, C.; Poirier, M.

    2012-01-01

    Large Scale Integrated Testing (LSIT) is being planned by Bechtel National, Inc. to address uncertainties in the full scale mixing performance of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. External review boards have raised questions regarding the overall representativeness of simulants used in previous mixing tests. Accordingly, WTP requested the Savannah River National Laboratory (SRNL) to assist with development of simulants for use in LSIT. Among the first tasks assigned to SRNL was to develop a list of waste properties that matter to pulse-jet mixer (PJM) mixing of WTP tanks. This report satisfies Commitment 5.2.3.1 of the Department of Energy Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 2010-2: physical properties important to mixing and scaling. In support of waste simulant development, the following two objectives are the focus of this report: (1) Assess physical and chemical properties important to the testing and development of mixing scaling relationships; (2) Identify the governing properties and associated ranges for LSIT to achieve the Newtonian and non-Newtonian test objectives. This includes the properties to support testing of sampling and heel management systems. The test objectives for LSIT relate to transfer and pump out of solid particles, prototypic integrated operations, sparger operation, PJM controllability, vessel level/density measurement accuracy, sampling, heel management, PJM restart, design and safety margin, Computational Fluid Dynamics (CFD) Verification and Validation (V and V) and comparison, performance testing and scaling, and high temperature operation. The slurry properties that are most important to Performance Testing and Scaling depend on the test objective and rheological classification of the slurry (i

  6. PROPERTIES IMPORTANT TO MIXING FOR WTP LARGE SCALE INTEGRATED TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Koopman, D.; Martino, C.; Poirier, M.

    2012-04-26

    Large Scale Integrated Testing (LSIT) is being planned by Bechtel National, Inc. to address uncertainties in the full scale mixing performance of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. External review boards have raised questions regarding the overall representativeness of simulants used in previous mixing tests. Accordingly, WTP requested the Savannah River National Laboratory (SRNL) to assist with development of simulants for use in LSIT. Among the first tasks assigned to SRNL was to develop a list of waste properties that matter to pulse-jet mixer (PJM) mixing of WTP tanks. This report satisfies Commitment 5.2.3.1 of the Department of Energy Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 2010-2: physical properties important to mixing and scaling. In support of waste simulant development, the following two objectives are the focus of this report: (1) Assess physical and chemical properties important to the testing and development of mixing scaling relationships; (2) Identify the governing properties and associated ranges for LSIT to achieve the Newtonian and non-Newtonian test objectives. This includes the properties to support testing of sampling and heel management systems. The test objectives for LSIT relate to transfer and pump out of solid particles, prototypic integrated operations, sparger operation, PJM controllability, vessel level/density measurement accuracy, sampling, heel management, PJM restart, design and safety margin, Computational Fluid Dynamics (CFD) Verification and Validation (V and V) and comparison, performance testing and scaling, and high temperature operation. The slurry properties that are most important to Performance Testing and Scaling depend on the test objective and rheological classification of the slurry (i

  7. Guidelineness of the parameters using integrated test in down syndrome risk prediction

    International Nuclear Information System (INIS)

    Lee, Jin Won; Go, Sung Jin; Kang, Se Sik; Kim, Chang Soo

    2016-01-01

    This study was an evaluation of the significance of each parameter through aimed at pregnant women subjected to screening test(integrated test) in predicting risk of Down syndrome. We retrospectively analysed the correlation of risk of Down's syndrome with Nuchal Translucency(NT) images measured by ultrasound, Pregnancy Associated Plasma Protein A(PAPP-A), alpha-fetoprotein(AFP), unconjugated estriol(uE3), human chorionic gonadotrophin(hCG) and Inhibin A by maternal serum. As a result, a significant correlation with NT, uE3, hCG, Inhibin A is revealed with Down's syndrome risk(P<.001). In ROC analysis, AUC of Inhibin A is analysed as the biggest predictor of Down's syndrome(0.859). And the criterion for cut-off was inhibin A 1.4 MoM(sensitivity 81.8%, specificity 75.9%). In conclusion, Inhibin A was the most useful in parameters to predict Down's syndrome in the integrated test. If we make up for the weakness based on the cut-off value of parameters they will be able to be used as an independent indicator in the risk of Down's syndrome screening

  8. An Integration Testing Facility for the CERN Accelerator Controls System

    CERN Document Server

    Stapley, N; Bau, J C; Deghaye, S; Dehavay, C; Sliwinski, W; Sobczak, M

    2009-01-01

    A major effort has been invested in the design, development, and deployment of the LHC Control System. This large control system is made up of a set of core components and dependencies, which although tested individually, are often not able to be tested together on a system capable of representing the complete control system environment, including hardware. Furthermore this control system is being adapted and applied to CERN's whole accelerator complex, and in particular for the forthcoming renovation of the PS accelerators. To ensure quality is maintained as the system evolves, and toimprove defect prevention, the Controls Group launched a project to provide a dedicated facility for continuous, automated, integration testing of its core components to incorporate into its production process. We describe the project, initial lessons from its application, status, and future directions.

  9. Automated Break-Out Box for use with Low Cost Spacecraft Integration and Test, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Electrical checkout and testing is a critical part of the overall spacecraft integration and test flow. Verifying proper harness and connector signal interfaces is...

  10. Integrated corridor management initiative : demonstration phase evaluation, Dallas air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States : Department of Transportation (U.S. DOT) evaluation of the Dallas U.S. 75 Integrated Corridor : Management (ICM) Initiative Demonstration. The ICM proje...

  11. Review of recent benchmark experiments on integral test for high energy nuclear data evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi; Tanaka, Susumu; Konno, Chikara; Fukahori, Tokio; Hayashi, Katsumi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    A survey work of recent benchmark experiments on an integral test for high energy nuclear data evaluation was carried out as one of the work of the Task Force on JENDL High Energy File Integral Evaluation (JHEFIE). In this paper the results are compiled and the status of recent benchmark experiments is described. (author)

  12. Major results from safety-related integral effect tests with VISTA-ITL for the SMART design

    International Nuclear Information System (INIS)

    Park, H. S.; Min, B. Y.; Shin, Y. C.; Yi, S. J.

    2012-01-01

    A series of integral effect tests (IETs) was performed by the Korea Atomic Energy Research Inst. (KAERI) using the VISTA integral test loop (VISTA-ITL) as a small-scale IET program. Among them this paper presents major results acquired from the safety-related IETs with the VISTA-ITL facility for the SMART design. Three small-break loss-of-coolant accident (SBLOCA) tests of safety injection system (SIS) line break, shutdown cooling system (SCS) line break and pressurizer safety valve (PSV) line break were successfully performed and the transient characteristics of a complete loss of flowrate (CLOF) was simulated properly with the VISTA-ITL facility. (authors)

  13. VLT deformable secondary mirror: integration and electromechanical tests results

    Science.gov (United States)

    Biasi, R.; Andrighettoni, M.; Angerer, G.; Mair, C.; Pescoller, D.; Lazzarini, P.; Anaclerio, E.; Mantegazza, M.; Gallieni, D.; Vernet, E.; Arsenault, R.; Madec, P.-Y.; Duhoux, P.; Riccardi, A.; Xompero, M.; Briguglio, R.; Manetti, M.; Morandini, M.

    2012-07-01

    The VLT Deformable secondary is planned to be installed on the VLT UT#4 as part of the telescope conversion into the Adaptive Optics test Facility (AOF). The adaptive unit is based on the well proven contactless, voice coil motor technology that has been already successfully implemented in the MMT, LBT and Magellan adaptive secondaries, and is considered a promising technical choice for the forthcoming ELT-generation adaptive correctors, like the E-ELT M4 and the GMT ASM. The VLT adaptive unit has been recently assembled after the completion of the manufacturing and modular test phases. In this paper, we present the most relevant aspects of the system integration and report the preliminary results of the electromechanical tests performed on the unit. This test campaign is a typical major step foreseen in all similar systems built so far: thanks to the metrology embedded in the system, that allows generating time-dependent stimuli and recording in real time the position of the controlled mirror on all actuators, typical dynamic response quality parameters like modal settling time, overshoot and following error can be acquired without employing optical measurements. In this way the system dynamic and some aspect of its thermal and long term stability can be fully characterized before starting the optical tests and calibrations.

  14. Using an Integrated Distributed Test Architecture to Develop an Architecture for Mars

    Science.gov (United States)

    Othon, William L.

    2016-01-01

    The creation of a crew-rated spacecraft architecture capable of sending humans to Mars requires the development and integration of multiple vehicle systems and subsystems. Important new technologies will be identified and matured within each technical discipline to support the mission. Architecture maturity also requires coordination with mission operations elements and ground infrastructure. During early architecture formulation, many of these assets will not be co-located and will required integrated, distributed test to show that the technologies and systems are being developed in a coordinated way. When complete, technologies must be shown to function together to achieve mission goals. In this presentation, an architecture will be described that promotes and advances integration of disparate systems within JSC and across NASA centers.

  15. Integrated Vibration and Acceleration Testing to Reduce Payload Mass, Cost and Mission Risk, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a capability to provide integrated acceleration, vibration, and shock testing using a state-of-the-art centrifuge, allowing for the test of...

  16. Compact reversed-field pinch reactors (CRFPR)

    International Nuclear Information System (INIS)

    Krakowski, R.A.; Hagenson, R.L.; Schnurr, N.M.; Copenhaver, C.; Bathke, C.G.; Miller, R.L.; Embrechts, M.J.

    1986-01-01

    The unique confinement properties of the poloidal-field-dominated Reversed-Field Pinch (RFP) are exploited to examine physics and technical issues related to a compact high-power-density fusion reactor. This resistive-coil, steady-state, toroidal device would use a dual-media (i.e., two separate coolants) power cycle that would be driven by a fusion power core (FPC, i.e., plasma chamber, first wall, blanket, shield, and coils) having a power density and mass approaching pressurized-water-fission reactor values. A 1000-MWe(net) base case is selected from a comprehensive trade-off study to examine technological issues related to operating a high-power-density FPC. A general rationale outlining the need for improved fusion concepts is given, followed by a description of the RFP principle, a detailed systems and trade-off analysis, and a conceptual FPC design for the ∝ 20-MW/m 2 (neutrons) compact RFP reactor, CRFPR(20). Key FPC components are quantified, and full power-balance, thermal, and mechanical FPC integrations are given. (orig.)

  17. Helicopter Field Testing of NASA's Autonomous Landing and Hazard Avoidance Technology (ALHAT) System fully Integrated with the Morpheus Vertical Test Bed Avionics

    Science.gov (United States)

    Epp, Chirold D.; Robertson, Edward A.; Ruthishauser, David K.

    2013-01-01

    The Autonomous Landing and Hazard Avoidance Technology (ALHAT) Project was chartered to develop and mature to a Technology Readiness Level (TRL) of six an autonomous system combining guidance, navigation and control with real-time terrain sensing and recognition functions for crewed, cargo, and robotic planetary landing vehicles. The ALHAT System must be capable of identifying and avoiding surface hazards to enable a safe and accurate landing to within tens of meters of designated and certified landing sites anywhere on a planetary surface under any lighting conditions. This is accomplished with the core sensing functions of the ALHAT system: Terrain Relative Navigation (TRN), Hazard Detection and Avoidance (HDA), and Hazard Relative Navigation (HRN). The NASA plan for the ALHAT technology is to perform the TRL6 closed loop demonstration on the Morpheus Vertical Test Bed (VTB). The first Morpheus vehicle was lost in August of 2012 during free-flight testing at Kennedy Space Center (KSC), so the decision was made to perform a helicopter test of the integrated ALHAT System with the Morpheus avionics over the ALHAT planetary hazard field at KSC. The KSC helicopter tests included flight profiles approximating planetary approaches, with the entire ALHAT system interfaced with all appropriate Morpheus subsystems and operated in real-time. During these helicopter flights, the ALHAT system imaged the simulated lunar terrain constructed in FY2012 to support ALHAT/Morpheus testing at KSC. To the best of our knowledge, this represents the highest fidelity testing of a system of this kind to date. During this helicopter testing, two new Morpheus landers were under construction at the Johnson Space Center to support the objective of an integrated ALHAT/Morpheus free-flight demonstration. This paper provides an overview of this helicopter flight test activity, including results and lessons learned, and also provides an overview of recent integrated testing of ALHAT on the second

  18. The multiscale expansions of difference equations in the small lattice spacing regime, and a vicinity and integrability test: I

    International Nuclear Information System (INIS)

    Santini, Paolo Maria

    2010-01-01

    We propose an algorithmic procedure (i) to study the 'distance' between an integrable PDE and any discretization of it, in the small lattice spacing ε regime, and, at the same time, (ii) to test the (asymptotic) integrability properties of such discretization. This method should provide, in particular, useful and concrete information on how good is any numerical scheme used to integrate a given integrable PDE. The procedure, illustrated on a fairly general ten-parameter family of discretizations of the nonlinear Schroedinger equation, consists of the following three steps: (i) the construction of the continuous multiscale expansion of a generic solution of the discrete system at all orders in ε, following Degasperis et al (1997 Physica D 100 187-211); (ii) the application, to such an expansion, of the Degasperis-Procesi (DP) integrability test (Degasperis A and Procesi M 1999 Asymptotic integrability Symmetry and Perturbation Theory, SPT98, ed A Degasperis and G Gaeta (Singapore: World Scientific) pp 23-37; Degasperis A 2001 Multiscale expansion and integrability of dispersive wave equations Lectures given at the Euro Summer School: 'What is integrability?' (Isaac Newton Institute, Cambridge, UK, 13-24 August); Integrability (Lecture Notes in Physics vol 767) ed A Mikhailov (Berlin: Springer)), to test the asymptotic integrability properties of the discrete system and its 'distance' from its continuous limit; (iii) the use of the main output of the DP test to construct infinitely many approximate symmetries and constants of motion of the discrete system, through novel and simple formulas.

  19. Testing an integrated behavioural and biomedical model of disability in N-of-1 studies with chronic pain.

    Science.gov (United States)

    Quinn, Francis; Johnston, Marie; Johnston, Derek W

    2013-01-01

    Previous research has supported an integrated biomedical and behavioural model explaining activity limitations. However, further tests of this model are required at the within-person level, because while it proposes that the constructs are related within individuals, it has primarily been tested between individuals in large group studies. We aimed to test the integrated model at the within-person level. Six correlational N-of-1 studies in participants with arthritis, chronic pain and walking limitations were carried out. Daily measures of theoretical constructs were collected using a hand-held computer (PDA), the activity was assessed by self-report and accelerometer and the data were analysed using time-series analysis. The biomedical model was not supported as pain impairment did not predict activity, so the integrated model was supported partially. Impairment predicted intention to move around, while perceived behavioural control (PBC) and intention predicted activity. PBC did not predict activity limitation in the expected direction. The integrated model of disability was partially supported within individuals, especially the behavioural elements. However, results suggest that different elements of the model may drive activity (limitations) for different individuals. The integrated model provides a useful framework for understanding disability and suggests interventions, and the utility of N-of-1 methodology for testing theory is illustrated.

  20. Spacecraft System Integration and Test: SSTI Lewis critical design audit

    Science.gov (United States)

    Brooks, R. P.; Cha, K. K.

    1995-01-01

    The Critical Design Audit package is the final detailed design package which provides a comprehensive description of the SSTI mission. This package includes the program overview, the system requirements, the science and applications activities, the ground segment development, the assembly, integration and test description, the payload and technology demonstrations, and the spacecraft bus subsystems. Publication and presentation of this document marks the final requirements and design freeze for SSTI.

  1. Integration of the PHIN RF Gun into the CLIC Test Facility

    CERN Document Server

    Döbert, Steffen

    2006-01-01

    CERN is a collaborator within the European PHIN project, a joint research activity for Photo injectors within the CARE program. A deliverable of this project is an rf Gun equipped with high quantum efficiency Cs2Te cathodes and a laser to produce the nominal beam for the CLIC Test Facility (CTF3). The nominal beam for CTF3 has an average current of 3.5 A, 1.5 GHz bunch repetition frequency and a pulse length of 1.5 ìs (2332 bunches) with quite tight stability requirements. In addition a phase shift of 180 deg is needed after each train of 140 ns for the special CLIC combination scheme. This rf Gun will be tested at CERN in fall 2006 and shall be integrated as a new injector into the CTF3 linac, replacing the existing injector consisting of a thermionic gun and a subharmonic bunching system. The paper studies the optimal integration into the machine trying to optimize transverse and longitudinal phase space of the beam while respecting the numerous constraints of the existing accelerator. The presented scheme...

  2. Coal-fired MHD test progress at the Component Development and Integration Facility

    International Nuclear Information System (INIS)

    Hart, A.T.; Rivers, T.J.; Alsberg, C.M.; Filius, K.D.

    1992-01-01

    The Component Development and Integration Facility (CDIF) is a Department of Energy test facility operated by MSE, Inc. In the fall of 1984, a 50-MW t , pressurized, slag rejecting coal-fired combustor (CFC) replaced the oil-fired combustor in the test train. In the spring of 1989, a coal-fired precombustor was added to the test hardware, and current controls were installed in the spring of 1990. In the fall of 1990, the slag rejector was installed. MSE test hardware activities included installing the final workhorse channel and modifying the coalfired combustor by installing improved design and proof-of-concept (POC) test pieces. This paper discusses the involvement of this hardware in test progress during the past year. Testing during the last year emphasized the final workhorse hardware testing. This testing will be discussed. Facility modifications and system upgrades for improved operation and duration testing will be discussed. In addition, this paper will address long-term testing plans

  3. Scaling Analysis Techniques to Establish Experimental Infrastructure for Component, Subsystem, and Integrated System Testing

    Energy Technology Data Exchange (ETDEWEB)

    Sabharwall, Piyush [Idaho National Laboratory (INL), Idaho Falls, ID (United States); O' Brien, James E. [Idaho National Laboratory (INL), Idaho Falls, ID (United States); McKellar, Michael G. [Idaho National Laboratory (INL), Idaho Falls, ID (United States); Housley, Gregory K. [Idaho National Laboratory (INL), Idaho Falls, ID (United States); Bragg-Sitton, Shannon M. [Idaho National Laboratory (INL), Idaho Falls, ID (United States)

    2015-03-01

    Hybrid energy system research has the potential to expand the application for nuclear reactor technology beyond electricity. The purpose of this research is to reduce both technical and economic risks associated with energy systems of the future. Nuclear hybrid energy systems (NHES) mitigate the variability of renewable energy sources, provide opportunities to produce revenue from different product streams, and avoid capital inefficiencies by matching electrical output to demand by using excess generation capacity for other purposes when it is available. An essential step in the commercialization and deployment of this advanced technology is scaled testing to demonstrate integrated dynamic performance of advanced systems and components when risks cannot be mitigated adequately by analysis or simulation. Further testing in a prototypical environment is needed for validation and higher confidence. This research supports the development of advanced nuclear reactor technology and NHES, and their adaptation to commercial industrial applications that will potentially advance U.S. energy security, economy, and reliability and further reduce carbon emissions. Experimental infrastructure development for testing and feasibility studies of coupled systems can similarly support other projects having similar developmental needs and can generate data required for validation of models in thermal energy storage and transport, energy, and conversion process development. Experiments performed in the Systems Integration Laboratory will acquire performance data, identify scalability issues, and quantify technology gaps and needs for various hybrid or other energy systems. This report discusses detailed scaling (component and integrated system) and heat transfer figures of merit that will establish the experimental infrastructure for component, subsystem, and integrated system testing to advance the technology readiness of components and systems to the level required for commercial

  4. Requirements for UML and OWL Integration Tool for User Data Consistency Modeling and Testing

    DEFF Research Database (Denmark)

    Nytun, J. P.; Jensen, Christian Søndergaard; Oleshchuk, V. A.

    2003-01-01

    The amount of data available on the Internet is continuously increasing, consequentially there is a growing need for tools that help to analyse the data. Testing of consistency among data received from different sources is made difficult by the number of different languages and schemas being used....... In this paper we analyze requirements for a tool that support integration of UML models and ontologies written in languages like the W3C Web Ontology Language (OWL). The tool can be used in the following way: after loading two legacy models into the tool, the tool user connects them by inserting modeling......, an important part of this technique is attaching of OCL expressions to special boolean class attributes that we call consistency attributes. The resulting integration model can be used for automatic consistency testing of two instances of the legacy models by automatically instantiate the whole integration...

  5. Latch-up and radiation integrated circuit--LURIC: a test chip for CMOS latch-up investigation

    International Nuclear Information System (INIS)

    Estreich, D.B.

    1978-11-01

    A CMOS integrated circuit test chip (Latch-Up and Radiation Integrated Circuit--LURIC) designed for CMOS latch-up and radiation effects research is described. The purpose of LURIC is (a) to provide information on the physics of CMOS latch-up, (b) to study the layout dependence of CMOS latch-up, and (c) to provide special latch-up test structures for the development and verification of a latch-up model. Many devices and test patterns on LURIC are also well suited for radiation effects studies. LURIC contains 86 devices and related test structures. A 12-layer mask set allows both metal gate CMOS and silicon gate ELA (Extended Linear Array) CMOS to be fabricated. Six categories of test devices and related test structures are included. These are (a) the CD4007 metal gate CMOS IC with auxiliary test structures, (b) ELA CMOS cells, (c) field-aided lateral pnp transistors, (d) p-well and substrate spreading resistance test structures, (e) latch-up test structures (simplified symmetrical latch-up paths), and (f) support test patterns (e.g., MOS capacitors, p + n diodes, MOS test transistors, van der Pauw and Kelvin contact resistance test patterns, etc.). A standard probe pattern array has been used on all twenty-four subchips for testing convenience

  6. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  7. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    CERN Document Server

    Wildish, Anthony

    2013-01-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future.The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services (PhEDEx, DBS, DAS). It allows cross-system integration tests of all three components to be performed in contr...

  8. [An experimental study on a slow-release complex with rifampicin-polylactic-co-glycolic acid-calcium 
phosphate cement].

    Science.gov (United States)

    Wu, Jianhuang; Ding, Zhou; Lei, Qing; Li, Miao; Liang, Yan; Lu, Tao

    2016-09-28

    To prepare the slow-release complex with rifampicin (RFP)-polylactic-co-glycolic acid (PLGA)-calcium phosphate cement (CPC) (RFP-PLGA-CPC complex), and to study its physical and chemical properties and drug release properties in vitro.
 The emulsification-solvent evaporation method was adopted to prepare rifampicin polylactic acid-glycolic acid (RFP-PLGA) slow-release microspheres, which were divided into 3 groups: a calcium phosphate bone cement group (CPC group), a CPC embedded with RFP group (RFP-CPC group), and a PLGA slow-release microspheres carrying RFP and the self-curing CPC group (RFP- PLGA-CPC complex group). The solidification time and porosity of materials were determined. The drug release experiments in vitro were carried out to observe the compressive strength, the change of section morphology before and after drug release. 
 The CPC group showed the shortest solidification time, while the RFP-PLGA-CPC complex group had the longest one. There was statistical difference in the porosity between the CPC group and the RFP-CPC group (Pbehavior of the complex, which was in accordance with zero order kinetics equation F=0.168×t.
 The porosity of RFP-PLGA-CPC complex is significantly higher than that of CPC, and it can keep slow release of the effective anti-tuberculosis drugs and maintain a certain mechanical strength for a long time.

  9. The PWR integrated leak rate test, a review of experiences and results

    International Nuclear Information System (INIS)

    Keogh, P.

    1985-01-01

    The paper reviews the Integrated Leak Rate Test (ILRT) as it has been carried out in the USA and as reported in papers in European countries. The test procedures are critically appraised and recommendations are given for modifications to them. The values used in a PWR are identified as a main source of leaks and possibilities for improvement are discussed. The use of a part pressure test and its limitations are considered. A part pressure test cannot give the same assurance as a full pressure test but may be useful for the identification of gross leaks. Secondary effects such as weather and the use of Van de Waals equations are considered and are found to be not important for concrete containments. (orig.)

  10. Cryogenic Fiber Optic Assemblies for Spaceflight Environments: Design, Manufacturing, Testing, and Integration

    Science.gov (United States)

    Thomes, W. Joe; Ott, Melanie N.; Chuska, Richard; Switzer, Robert; Onuma, Eleanya; Blair, Diana; Frese, Erich; Matyseck, Marc

    2016-01-01

    Fiber optic assemblies have been used on spaceflight missions for many years as an enabling technology for routing, transmitting, and detecting optical signals. Due to the overwhelming success of NASA in implementing fiber optic assemblies on spaceflight science-based instruments, system scientists increasingly request fibers that perform in extreme environments while still maintaining very high optical transmission, stability, and reliability. Many new applications require fiber optic assemblies that will operate down to cryogenic temperatures as low as 20 Kelvin. In order for the fiber assemblies to operate with little loss in optical throughput at these extreme temperatures requires a system level approach all the way from how the fiber assembly is manufactured to how it is held, routed, and integrated. The NASA Goddard Code 562 Photonics Group has been designing, manufacturing, testing, and integrating fiber optics for spaceflight and other high reliability applications for nearly 20 years. Design techniques and lessons learned over the years are consistently applied to developing new fiber optic assemblies that meet these demanding environments. System level trades, fiber assembly design methods, manufacturing, testing, and integration will be discussed. Specific recent examples of ground support equipment for the James Webb Space Telescope (JWST); the Ice, Cloud and Land Elevation Satellite-2 (ICESat-2); and others will be included.

  11. Guidelineness of the parameters using integrated test in down syndrome risk prediction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Won [Graduate School of Catholic University of Pusan, Busan (Korea, Republic of); Go, Sung Jin; Kang, Se Sik; Kim, Chang Soo [Dept. Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2016-12-15

    This study was an evaluation of the significance of each parameter through aimed at pregnant women subjected to screening test(integrated test) in predicting risk of Down syndrome. We retrospectively analysed the correlation of risk of Down's syndrome with Nuchal Translucency(NT) images measured by ultrasound, Pregnancy Associated Plasma Protein A(PAPP-A), alpha-fetoprotein(AFP), unconjugated estriol(uE3), human chorionic gonadotrophin(hCG) and Inhibin A by maternal serum. As a result, a significant correlation with NT, uE3, hCG, Inhibin A is revealed with Down's syndrome risk(P<.001). In ROC analysis, AUC of Inhibin A is analysed as the biggest predictor of Down's syndrome(0.859). And the criterion for cut-off was inhibin A 1.4 MoM(sensitivity 81.8%, specificity 75.9%). In conclusion, Inhibin A was the most useful in parameters to predict Down's syndrome in the integrated test. If we make up for the weakness based on the cut-off value of parameters they will be able to be used as an independent indicator in the risk of Down's syndrome screening.

  12. The multiscale expansions of difference equations in the small lattice spacing regime, and a vicinity and integrability test: I

    Science.gov (United States)

    Santini, Paolo Maria

    2010-01-01

    We propose an algorithmic procedure (i) to study the 'distance' between an integrable PDE and any discretization of it, in the small lattice spacing epsilon regime, and, at the same time, (ii) to test the (asymptotic) integrability properties of such discretization. This method should provide, in particular, useful and concrete information on how good is any numerical scheme used to integrate a given integrable PDE. The procedure, illustrated on a fairly general ten-parameter family of discretizations of the nonlinear Schrödinger equation, consists of the following three steps: (i) the construction of the continuous multiscale expansion of a generic solution of the discrete system at all orders in epsilon, following Degasperis et al (1997 Physica D 100 187-211) (ii) the application, to such an expansion, of the Degasperis-Procesi (DP) integrability test (Degasperis A and Procesi M 1999 Asymptotic integrability Symmetry and Perturbation Theory, SPT98, ed A Degasperis and G Gaeta (Singapore: World Scientific) pp 23-37 Degasperis A 2001 Multiscale expansion and integrability of dispersive wave equations Lectures given at the Euro Summer School: 'What is integrability?' (Isaac Newton Institute, Cambridge, UK, 13-24 August); Integrability (Lecture Notes in Physics vol 767) ed A Mikhailov (Berlin: Springer)), to test the asymptotic integrability properties of the discrete system and its 'distance' from its continuous limit; (iii) the use of the main output of the DP test to construct infinitely many approximate symmetries and constants of motion of the discrete system, through novel and simple formulas.

  13. Operational Overview for UAS Integration in the NAS Project Flight Test Series 3

    Science.gov (United States)

    Valkov, Steffi B.; Sternberg, Daniel; Marston, Michael

    2018-01-01

    The National Aeronautics and Space Administration Unmanned Aircraft Systems Integration in the National Airspace System Project has conducted a series of flight tests intended to support the reduction of barriers that prevent unmanned aircraft from flying without the required waivers from the Federal Aviation Administration. The 2015 Flight Test Series 3, supported two separate test configurations. The first configuration investigated the timing of Detect and Avoid alerting thresholds using a radar equipped unmanned vehicle and multiple live intruders flown at varying encounter geometries.

  14. Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction.

    Science.gov (United States)

    Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua

    2015-01-01

    A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base.

  15. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  16. Dynamics of red fluorescent dental plaque during experimental gingivitis--A cohort study.

    Science.gov (United States)

    van der Veen, Monique H; Volgenant, Catherine M C; Keijser, Bart; Ten Cate, Jacob Bob M; Crielaard, Wim

    2016-05-01

    The dynamics of red fluorescent plaque (RFP) in comparison to clinical plaque and bleeding scores were studied during an experimental gingivitis protocol in a cohort of healthy participants. Forty-one participants were monitored for RFP before (24h plaque), during 14 days plaque accumulation (days 2, 5, 9, 14) and after 7 days recovery (24h plaque). RFP was assessed on fluorescence photographs of the vestibular aspect of the anterior teeth (cuspid to cuspid) in the upper and lower jaw. Clinical plaque and bleeding were assessed at days -14, 0, 14 and 21. RFP of 24h plaque was reproducible (days -14, 0), then increased during 14 days plaque accumulation and returned to baseline after 7 days recovery. Groups of low, moderate and high RFP formers were statistically significantly different at all times even already at baseline. The individual RFP response during 14 days plaque accumulation correlated well with RFP of 24h plaque (days -14, 0). RFP correlated moderate to well with clinical plaque at days -14, 0, 14 and 21. From day 2 of the gingivitis challenge RFP correlated with bleeding at day 14. RFP provided an objective measure of oral hygiene status. Given the correlation with clinical parameters found, the amount of RFP after 24h plaque accumulation was indicatory for the inflammatory response during a prolonged period of no oral hygiene. This trial was registered at the public trial register ​of the Central Committee on Research Involving Human Subjects (CCMO) under number NL51111.029.14 CLINICAL SIGNIFICANCE: This paper shows the association between RFP after 24h plaque accumulation and inflammatory response after a prolonged period of no oral hygiene. Red plaque fluorescence can be used to identify subjects at risk for developing gingival inflammation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. BWR full integral simulation test (FIST) pretest predictions with TRACBO2

    International Nuclear Information System (INIS)

    Sutherland, W.A.; Alamgir, M.

    1984-01-01

    The Full Integral Simulation Test program is a three pronged approach to the development of best-estimate analysis capability for BWR systems. An analytical method development program is underway to extend the BWR-TRAC computer code to model reactor kinetics and major interfacing systems, including balance-of-plant, to improve application modeling flexibility, and to reduce computer running time. An experimental program is underway in a new single bundle system test facility to extend the large break loss-of-coolant accident LOCA data base to small breaks and operational transients. And a method qualification program is underway to test TRACBO2 against experiments in the FIST facility. The recently completed Phase 1 period included a series of LOCA and power transient tests, and successful pretest analysis of the large and small break LOCA tests with TRACBO2. These comparisons demonstrate BWR-TRAC capability for small and large break analysis, and provide detailed understanding of the phenomena

  18. Integral test of JENDL-3.3 on fast reactors

    International Nuclear Information System (INIS)

    Chiba, Gou; Hazama, Taira

    2003-05-01

    An integral test has been carried out to evaluate a performance of evaluated nuclear data library JENDL-3.3, which was newly released, in a view of applying neutronics analyses of fast reactors. Japan Nuclear Cycle Development Institute has a large amount of data of critical assembly experiments (ZPPR, BFS, MOZART and FCA) and power reactor tests (JOYO). The database was utilized in this test. In plutonium loaded cores, an improvement was observed about 0.3% ε k in criticality and 5% in the non-leakage term of sodium void reactivity by a revision form JENDL-3.2 to -3.3. These results shoed that the revision is valid in plutonium loaded cores. In uranium loaded cores, dependence of C/E values on control rod position became smaller in control rod worth in ZPPR cores. On the other hand, C/E values became worse both in criticality (0.6%εk) and in sodium void reactivity (30%) in BFS cores. The main cause was a revision of uranium-235 capture cross section, and it could not be concluded whether the revision is valid or not in uranium loaded cores. It is necessary to carry out a validation test at other independent critical experiments in which uranium fuel is used. (author)

  19. Automatic testing in the integration phase of mobile work machine (TINAT) - MASIT31

    Energy Technology Data Exchange (ETDEWEB)

    Multanen, P.; Hyvoenen, M. (Tampere University of Technology, Department of Intelligent Hydraulics and Automation, Tampere (Finland)); Ellman, A. (Tampere University of Technology, Department of Mechanics and Design, Tampere (Finland)); Rantala, S.; Alanen, J. (VTT Technical Research Centre of Finland, Espoo (Finland))

    2008-07-01

    Abstract The performance and reliability of mobile work machines are significantly affected by control systems of machines and their characteristics. Currently the testing of control systems and verification of their properties is often carried out just in the integration phase of controls and mechanical structure of machine. This is very time consuming, requires a lot of test personnel and is not extensive enough. In TINAT project a test concept will be developed for the testing of entire control systems of work machines without real the mechanical structures of the machines by utilizing modelling and real-time hardware-in-the-loop simulation. The simulator system enables automatic generation of test scenarios and automatic analysis and reporting of test results. (orig.)

  20. M109 Family of Vehicles, Paladin Integrated Management (PIM): Operational Assessment of the Initial Operational Test and Evaluation (IOT and E)

    Science.gov (United States)

    2017-01-01

    Director, Operational Test and Evaluation M109 Family of Vehicles, Paladin Integrated Management (PIM) Operational Assessment of the... operational suitability, test adequacy, and survivability of the M109 Family of Vehicles (FoV), known as Paladin Integrated Management (PIM) Self...prevent the M109A7 SPH-equipped unit from completing its mission. The Paladin Integrated Management (PIM) Initial Operational Test and Evaluation

  1. Integrated corridor management initiative : demonstration phase evaluation - Dallas technical capability analysis test plan.

    Science.gov (United States)

    This report presents the test plan for conducting the Technical Capability Analysis for the United States : Department of Transportation (U.S. DOT) evaluation of the Dallas U.S. 75 Integrated Corridor : Management (ICM) Initiative Demonstration. The ...

  2. The development of the conditionally replication-competent adenovirus: replacement of E4 orf1-4 region by exogenous gene.

    Science.gov (United States)

    Nam, Jae-Kook; Lee, Mi-Hyang; Seo, Hae-Hyun; Kim, Seok-Ki; Lee, Kang-Huyn; Kim, In-Hoo; Lee, Sang-Jin

    2010-05-01

    Tumor or tissue specific replicative adenovirus armed with a therapeutic gene has shown a promising anti-cancer therapeutic modality. However, because the genomic packaging capacity is constrained, only a few places inside it are available for transgene insertion. In the present study, we introduce a novel strategy utilizing the early E4 region for the insertion of therapeutic gene(s). We constructed the conditionally replication-competent adenovirus (CRAd), Ad5E4(mRFP) by: (i) replacing the E4/E1a promoter by the prostate-specific enhancer element; (ii) inserting mRFP inside the E4orf1-4 deletion region; and (iii) sub-cloning enhanced green fluorescent protein controlled by cytomegalovirus promoter in the left end of the viral genome. Subsequently, we evaluated its replication abilities and killing activities in vitro, as well as its in vivo anti-tumor efficacy in CWR22rv xenografts. When infected with Ad5E4(mRFP), the number and intensity of the mRFP gene products increased in a prostate cancer cell-specific manner as designed, suggesting that the mRFP gene and E4orfs other than E4orf1-4 were well synthesized from one transcript via alternative splicing as the recombinant adenovirus replicated. As expected from the confirmed virus replication capability, Ad5E4(mRFP) induced cell lysis as potent as the wild-type adenovirus and effectively suppressed tumor growth when tested in the CWR22rv xenografts in nude mice. Furthermore, Ad5E4(endo/angio) harboring an endostatin-angiostatin gene in E4orf1-4 was able to enhance CRAd by replacing mRFP with a therapeutic gene. The approach employed in the present study for the insertion of a therapeutic transgene in CRAd should facilitate the construction of CRAd containing multiple therapeutic genes in the viral genome that may have the potential to serve as highly potent cancer therapeutic reagents. Copyright (c) 2010 John Wiley & Sons, Ltd.

  3. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices

    Directory of Open Access Journals (Sweden)

    Bart Verhees

    2017-12-01

    Full Text Available Point-of-care testing (POCT—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP’s network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  4. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices.

    Science.gov (United States)

    Verhees, Bart; van Kuijk, Kees; Simonse, Lianne

    2017-12-21

    Point-of-care testing (POCT)-laboratory tests performed with new mobile devices and online technologies outside of the central laboratory-is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP's network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  5. Integral test facilities for validation of the performance of passive safety systems and natural circulation

    International Nuclear Information System (INIS)

    Choi, J. H.

    2010-10-01

    Passive safety systems are becoming an important component in advanced reactor designs. This has led to an international interest in examining natural circulation phenomena as this may play an important role in the operation of these passive safety systems. Understanding reactor system behaviour is a challenging process due to the complex interactions between components and associated phenomena. Properly scaled integral test facilities can be used to explore these complex interactions. In addition, system analysis computer codes can be used as predictive tools in understanding the complex reactor system behaviour. However, before the application of system analysis computer codes for reactor design, it is capability in making predictions needs to be validated against the experimental data from a properly scaled integral test facility. The IAEA has organized a coordinated research project (CRP) on natural circulation phenomena, modeling and reliability of passive systems that utilize natural circulation. This paper is a part of research results from this CRP and describes representative international integral test facilities that can be used for data collection for reactor types in which natural circulation may play an important role. Example experiments were described along with the analyses of these example cases in order to examine the ability of system codes to model the phenomena that are occurring in the test facilities. (Author)

  6. Integrated corridor management initiative : demonstration phase evaluation, San Diego air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM projects being...

  7. Integrated vehicle-based safety systems light-vehicle field operational test key findings report.

    Science.gov (United States)

    2011-01-01

    "This document presents key findings from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michigan Transportat...

  8. IOTA (Integrable Optics Test Accelerator): facility and experimental beam physics program

    Science.gov (United States)

    Antipov, S.; Broemmelsiek, D.; Bruhwiler, D.; Edstrom, D.; Harms, E.; Lebedev, V.; Leibfritz, J.; Nagaitsev, S.; Park, C. S.; Piekarz, H.; Piot, P.; Prebys, E.; Romanov, A.; Ruan, J.; Sen, T.; Stancari, G.; Thangaraj, C.; Thurman-Keup, R.; Valishev, A.; Shiltsev, V.

    2017-03-01

    The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150 MeV/c, respectively. The research program includes the study of nonlinear focusing integrable optical beam lattices based on special magnets and electron lenses, beam dynamics of space-charge effects and their compensation, optical stochastic cooling, and several other experiments. In this article, we present the design and main parameters of the facility, outline progress to date and provide the timeline of the construction, commissioning and research. The physical principles, design, and hardware implementation plans for the major IOTA experiments are also discussed.

  9. IOTA (Integrable Optics Test Accelerator): Facility and experimental beam physics program

    International Nuclear Information System (INIS)

    Antipov, Sergei; Broemmelsiek, Daniel; Bruhwiler, David; Edstrom, Dean; Harms, Elvin

    2017-01-01

    The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150 MeV/c, respectively. The research program includes the study of nonlinear focusing integrable optical beam lattices based on special magnets and electron lenses, beam dynamics of space-charge effects and their compensation, optical stochastic cooling, and several other experiments. In this article, we present the design and main parameters of the facility, outline progress to date and provide the timeline of the construction, commissioning and research. Finally, the physical principles, design, and hardware implementation plans for the major IOTA experiments are also discussed.

  10. Novel development of the micro-tensile test at elevated temperature using a test structure with integrated micro-heater

    Science.gov (United States)

    Ang, W. C.; Kropelnicki, P.; Soe, Oak; Ling, J. H. L.; Randles, A. B.; Hum, A. J. W.; Tsai, J. M. L.; Tay, A. A. O.; Leong, K. C.; Tan, C. S.

    2012-08-01

    This paper describes the novel development of a micro-tensile testing method that allows testing at elevated temperatures. Instead of using a furnace, a titanium/platinum thin film micro-heater was fabricated on a conventional dog-bone-shaped test structure to heat up its gauge section locally. An infrared (IR) camera with 5 µm resolution was employed to verify the temperature uniformity across the gauge section of the test structure. With this micro-heater-integrated test structure, micro-tensile tests can be performed at elevated temperatures using any conventional tensile testing system without any major modification to the system. In this study, the tensile test of the single crystal silicon (SCS) thin film with (1 0 0) surface orientation and tensile direction was performed at room temperature and elevated temperatures, up to 300 °C. Experimental results for Young's modulus as a function of temperature are presented. A micro-sized SCS film showed a low dependence of mechanical properties on temperature up to 300 °C.

  11. The electromagnetic integrated demonstration at the Idaho National Engineering Laboratory cold test pit

    International Nuclear Information System (INIS)

    Pellerin, L.; Alumbaugh, D.L.; Pfeifer, M.C.

    1997-01-01

    The electromagnetic integrated demonstration (EMID) is a baseline study in electromagnetic (EM) exploration of the shallow subsurface (< 10 m). Eleven distinct EM systems, covering the geophysical spectrum, acquired data on a grid over the Idaho National Engineering Laboratory (INEL) Cold Test Pit (CTP). The systems are investigated and evaluated for the purpose of identifying and reviewing existing geophysical characterization instrumentation (commercial and experimental), integrating those technologies with multi-dimensional interpretational algorithms, and identifying gaps in shallow subsurface EM imaging technology. The EMID data, are valuable for testing and evaluating new interpretational software, and developing techniques for integrating multiple datasets. The experimental field techniques shows how the acquisition of data in a variety of array configurations can considerably enhance interpretation. All data are available on the world wide web. Educators and students are encouraged to use the data for both classroom and graduate studies. The purpose of this paper is to explain why, where, how and what kind of data were collected. It is left to the reader to assess the value of a given system for their particular application. Information about the EMID is organized into two general categories: survey description and system evaluation

  12. Integral benchmark test of JENDL-4.0 for U-233 systems with ICSBEP handbook

    International Nuclear Information System (INIS)

    Kuwagaki, Kazuki; Nagaya, Yasunobu

    2017-03-01

    The integral benchmark test of JENDL-4.0 for U-233 systems using the continuous-energy Monte Carlo code MVP was conducted. The previous benchmark test was performed only for U-233 thermal solution and fast metallic systems in the ICSBEP handbook. In this study, MVP input files were prepared for uninvestigated benchmark problems in the handbook including compound thermal systems (mainly lattice systems) and integral benchmark test was performed. The prediction accuracy of JENDL-4.0 was evaluated for effective multiplication factors (k eff 's) of the U-233 systems. As a result, a trend of underestimation was observed for all the categories of U-233 systems. In the benchmark test of ENDF/B-VII.1 for U-233 systems with the ICSBEP handbook, it is reported that a decreasing trend of calculated k eff values in association with a parameter ATFF (Above-Thermal Fission Fraction) is observed. The ATFF values were also calculated in this benchmark test of JENDL-4.0 and the same trend as ENDF/B-VII.1 was observed. A CD-ROM is attached as an appendix. (J.P.N.)

  13. Test and verification of a reactor protection system application-specific integrated circuit

    International Nuclear Information System (INIS)

    Battle, R.E.; Turner, G.W.; Vandermolen, R.I.; Vitalbo, C.

    1997-01-01

    Application-specific integrated circuits (ASICs) were utilized in the design of nuclear plant safety systems because they have certain advantages over software-based systems and analog-based systems. An advantage they have over software-based systems is that an ASIC design can be simple enough to not include branch statements and also can be thoroughly tested. A circuit card on which an ASIC is mounted can be configured to replace various versions of older analog equipment with fewer design types required. The approach to design and testing of ASICs for safety system applications is discussed in this paper. Included are discussions of the ASIC architecture, how it is structured to assist testing, and of the functional and enhanced circuit testing

  14. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  15. Predicting Examination Performance Using an Expanded Integrated Hierarchical Model of Test Emotions and Achievement Goals

    Science.gov (United States)

    Putwain, Dave; Deveney, Carolyn

    2009-01-01

    The aim of this study was to examine an expanded integrative hierarchical model of test emotions and achievement goal orientations in predicting the examination performance of undergraduate students. Achievement goals were theorised as mediating the relationship between test emotions and performance. 120 undergraduate students completed…

  16. Integrated operations plan for the MFTF-B Mirror Fusion Test Facility. Volume II. Integrated operations plan

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    This document defines an integrated plan for the operation of the Lawrence Livermore National Laboratory (LLNL) Mirror Fusion Test Facility (MFTF-B). The plan fulfills and further delineates LLNL policies and provides for accomplishing the functions required by the program. This plan specifies the management, operations, maintenance, and engineering support responsibilities. It covers phasing into sustained operations as well as the sustained operations themselves. Administrative and Plant Engineering support, which are now being performed satisfactorily, are not part of this plan unless there are unique needs.

  17. Integrated operations plan for the MFTF-B Mirror Fusion Test Facility. Volume II. Integrated operations plan

    International Nuclear Information System (INIS)

    1981-12-01

    This document defines an integrated plan for the operation of the Lawrence Livermore National Laboratory (LLNL) Mirror Fusion Test Facility (MFTF-B). The plan fulfills and further delineates LLNL policies and provides for accomplishing the functions required by the program. This plan specifies the management, operations, maintenance, and engineering support responsibilities. It covers phasing into sustained operations as well as the sustained operations themselves. Administrative and Plant Engineering support, which are now being performed satisfactorily, are not part of this plan unless there are unique needs

  18. Night vision imaging system design, integration and verification in spacecraft vacuum thermal test

    Science.gov (United States)

    Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing

    2015-08-01

    The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.

  19. A review of the experimental and theoretical status of the reversed-field pinch

    International Nuclear Information System (INIS)

    Baker, D.A.

    1987-01-01

    This paper reviews the status of the reversed-field pinch (RFP) approach to the development of a compact nuclear fusion reactor. Two RFP papers in this conference are complementary; the first paper contains the historical origins and basic concepts concerning MHD instabilities, relaxation and RFP confinement properties as well as a discussion of future prospects of the RFP. This paper gives an overview of the status of plasma parameters of the present main RFP experiments and of the status of theory and experiment of the interesting RFP plasma phenomena of relaxation, self reversal and flux generation (these effects are often referred to as the dynamo effect). The low frequency oscillating-field current drive concept which exploits these effects is discussed. Particular emphasis is given to the theoretical results obtained from plasma simulation codes used in these active areas of study. Selected topics of recent research on the Los Alamos ZT-40M experiments are reported. The paper concludes with descriptions of the next generation Los Alamos RFP experiment ZTH, to be located in the new Confinement Physics Research Facility (CPRF) presently under construction, and the characteristics of an RFP compact reactor. 68 refs

  20. MUNI Ways and Structures Building Integrated Solar Membrane Project

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Randall

    2014-07-03

    renovated in 1998, but the existing roof had not been designed to carry a large load. Due to this fact, a complete roofing and structural analysis had to be performed to match the available roof loading to the existing and/or new solar PV technology, and BIPV was considered an excellent solution for this structure with the roof weight limitations. The solar BIPV system on the large roof area was estimated to provide about 25% of the total facility load with an average of 52,560 kWh per month. In order to accomplish the goals of the project, the following steps were performed: 1. SFPUC and consultants evaluated the structural capability of the facility roof, with recommendations for improvements necessary to accommodate the solar PV system and determine the suitable size of the system in kilowatts. The electrical room and switchgear were evaluated for any improvements necessary and to identify any constraints that might impede the installation of necessary inverters, transformers or meters. 2. Development of a design-build Request for Proposal (RFP) to identify the specifications for the solar PV system, and to include SFPUC technical specifications, equipment warranties and performance warranties. Due to potential labor issues in the local solar industry, SFPUC adjusted the terms of the RFP to more clearly define scope of work between electricians, roofers and laborers. 3. Design phase of project included electrical design drawings, calculations and other construction documents to support three submittals: 50% (preliminary design), 90% (detailed design) and 100% (Department of Building Inspection permit approved). 4. Installation of solar photovoltaic panels, completion of conduit and wiring work, connection of inverters, isolation switches, meters and Data Acquisition System by Contractor (Department of Public Works). 5. Commissioning of system, including all necessary tests to make the PV system fully functional and operational at its rated capacity of 100 kW (DC

  1. Integrated Disposal Facility FY 2012 Glass Testing Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, Eric M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kerisit, Sebastien N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Krogstad, Eirik J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Burton, Sarah D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bjornstad, Bruce N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Freedman, Vicky L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cantrell, Kirk J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Michelle MV [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Crum, Jarrod V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-03-29

    PNNL is conducting work to provide the technical basis for estimating radionuclide release from the engineered portion of the disposal facility for Hanford immobilized low-activity waste (ILAW). Before the ILAW can be disposed, DOE must conduct a performance assessment (PA) for the Integrated Disposal Facility (IDF) that describes the long-term impacts of the disposal facility on public health and environmental resources. As part of the ILAW glass testing program, PNNL is implementing a strategy, consisting of experimentation and modeling, to provide the technical basis for estimating radionuclide release from the glass waste form in support of future IDF PAs. Key activities in FY12 include upgrading the STOMP/eSTOMP codes to do near-field modeling, geochemical modeling of PCT tests to determine the reaction network to be used in the STOMP codes, conducting PUF tests on selected glasses to simulate and accelerate glass weathering, developing a Monte Carlo simulation tool to predict the characteristics of the weathered glass reaction layer as a function of glass composition, and characterizing glasses and soil samples exhumed from an 8-year lysimeter test. The purpose of this report is to summarize the progress made in fiscal year (FY) 2012 and the first quarter of FY 2013 toward implementing the strategy with the goal of developing an understanding of the long-term corrosion behavior of LAW glasses.

  2. Integration of the SSPM and STAGE with the MPACT Virtual Facility Distributed Test Bed.

    Energy Technology Data Exchange (ETDEWEB)

    Cipiti, Benjamin B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shoman, Nathan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    The Material Protection Accounting and Control Technologies (MPACT) program within DOE NE is working toward a 2020 milestone to demonstrate a Virtual Facility Distributed Test Bed. The goal of the Virtual Test Bed is to link all MPACT modeling tools, technology development, and experimental work to create a Safeguards and Security by Design capability for fuel cycle facilities. The Separation and Safeguards Performance Model (SSPM) forms the core safeguards analysis tool, and the Scenario Toolkit and Generation Environment (STAGE) code forms the core physical security tool. These models are used to design and analyze safeguards and security systems and generate performance metrics. Work over the past year has focused on how these models will integrate with the other capabilities in the MPACT program and specific model changes to enable more streamlined integration in the future. This report describes the model changes and plans for how the models will be used more collaboratively. The Virtual Facility is not designed to integrate all capabilities into one master code, but rather to maintain stand-alone capabilities that communicate results between codes more effectively.

  3. A unified framework for testing in the linear regression model under unknown order of fractional integration

    DEFF Research Database (Denmark)

    Christensen, Bent Jesper; Kruse, Robinson; Sibbertsen, Philipp

    We consider hypothesis testing in a general linear time series regression framework when the possibly fractional order of integration of the error term is unknown. We show that the approach suggested by Vogelsang (1998a) for the case of integer integration does not apply to the case of fractional...

  4. Testing an integrated model of operations capabilities An empirical study of Australian airlines

    NARCIS (Netherlands)

    Nand, Alka Ashwini; Singh, Prakash J.; Power, Damien

    2013-01-01

    Purpose - The purpose of this paper is to test the integrated model of operations strategy as proposed by Schmenner and Swink to explain whether firms trade-off or accumulate capabilities, taking into account their positions relative to their asset and operating frontiers.

  5. Split-cross-bridge resistor for testing for proper fabrication of integrated circuits

    Science.gov (United States)

    Buehler, M. G. (Inventor)

    1985-01-01

    An electrical testing structure and method is described whereby a test structure is fabricated on a large scale integrated circuit wafer along with the circuit components and has a van der Pauw cross resistor in conjunction with a bridge resistor and a split bridge resistor, the latter having two channels each a line width wide, corresponding to the line width of the wafer circuit components, and with the two channels separated by a space equal to the line spacing of the wafer circuit components. The testing structure has associated voltage and current contact pads arranged in a two by four array for conveniently passing currents through the test structure and measuring voltages at appropriate points to calculate the sheet resistance, line width, line spacing, and line pitch of the circuit components on the wafer electrically.

  6. Beam tests of an integrated prototype of the ATLAS Forward Proton detector

    CERN Document Server

    INSPIRE-00397348

    2016-09-19

    The ATLAS Forward Proton (AFP) detector is intended to measure protons scattered at small angles from the ATLAS interaction point. To this end, a combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov time-of-flight (ToF) detectors is installed 210m away from the interaction point at both sides of ATLAS. Beam tests with an AFP prototype detector combining tracking and timing sub-detectors and a common readout have been performed at the CERN-SPS test-beam facility in November 2014 and September 2015 to complete the system integration and to study the detector performance. The successful tracking-timing integration was demonstrated. Good tracker hit efficiencies above 99.9% at a sensor tilt of 14{\\deg}, as foreseen for AFP, were observed. Spatial resolutions in the short pixel direction with 50 {\\mu}m pitch of 5.5 +/- 0.5 {\\mu}m per pixel plane and of 2.8 +/- 0.5 {\\mu}m for the full four-plane tracker at 14{\\deg} were found, largely surpassing the AFP requirement of 10 {\\mu}m. The timing detector...

  7. Advances in prenatal screening for Down syndrome: II first trimester testing, integrated testing, and future directions.

    Science.gov (United States)

    Benn, Peter A

    2002-10-01

    The acceptability of prenatal screening and diagnosis of Down syndrome is dependent, in part, on the gestational age at which the testing is offered. First trimester screening could be advantageous if it has sufficient efficacy and can be effectively delivered. Two first trimester maternal serum screening markers, pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (beta-hCG), are useful for identifying women at increased risk for fetal Down syndrome. In addition, measurement of an enlarged thickness of the subcutaneous fluid-filled space at the back of the neck of the developing fetus (referred to as nuchal translucency or NT) has been demonstrated to be an indicator for these high-risk pregnancies. When these three parameters are combined, estimates for Down syndrome efficacy exceed those currently attainable in the second trimester. Women who are screen-positive in the first trimester can elect to receive cytogenetic testing of a chorionic villus biopsy. The first trimester tests could also, theoretically, be combined with the second trimester maternal serum screening tests (integrated screening) to obtain even higher levels of efficacy. There are, however, several practical limitations to first trimester and integrated screening. These include scheduling of testing within relatively narrow gestational age intervals, availability of appropriately trained ultrasonographers for NT measurement, risks associated with chorionic villus biopsy, and costs. There is also increasing evidence that an enlarged NT measurement is indicative of a high risk for spontaneous abortion and for fetal abnormalities that are not detectable by cytogenetic analysis. Women whose fetuses show enlarged NT, therefore, need first trimester counseling regarding their Down syndrome risks and the possibility of other adverse pregnancy outcomes. Follow-up ultrasound and fetal echocardiography in the second trimester are also indicated. First trimester

  8. The field-testing of a novel integrated mapping protocol for neglected tropical diseases.

    Directory of Open Access Journals (Sweden)

    Sonia Pelletreau

    2011-11-01

    Full Text Available BACKGROUND: Vertical control and elimination programs focused on specific neglected tropical diseases (NTDs can achieve notable success by reducing the prevalence and intensity of infection. However, many NTD-endemic countries have not been able to launch or scale-up programs because they lack the necessary baseline data for planning and advocacy. Each NTD program has its own mapping guidelines to collect missing data. Where geographic overlap among NTDs exists, an integrated mapping approach could result in significant resource savings. We developed and field-tested an innovative integrated NTD mapping protocol (Integrated Threshold Mapping (ITM Methodology for lymphatic filariasis (LF, trachoma, schistosomiasis and soil-transmitted helminths (STH. METHODOLOGY/PRINCIPAL FINDINGS: The protocol is designed to be resource-efficient, and its specific purpose is to determine whether a threshold to trigger public health interventions in an implementation unit has been attained. The protocol relies on World Health Organization (WHO recommended indicators in the disease-specific age groups. For each disease, the sampling frame was the district, but for schistosomiasis, the sub-district rather than the ecological zone was used. We tested the protocol by comparing it to current WHO mapping methodologies for each of the targeted diseases in one district each in Mali and Senegal. Results were compared in terms of public health intervention, and feasibility, including cost. In this study, the ITM methodology reached the same conclusions as the WHO methodologies regarding the initiation of public health interventions for trachoma, LF and STH, but resulted in more targeted intervention recommendations for schistosomiasis. ITM was practical, feasible and demonstrated an overall cost saving compared with the standard, non-integrated, WHO methodologies. CONCLUSIONS/SIGNIFICANCE: This integrated mapping tool could facilitate the implementation of much

  9. Applying Adverse Outcome Pathways (AOPs) to support Integrated Approaches to Testing and Assessment (IATA).

    Science.gov (United States)

    Tollefsen, Knut Erik; Scholz, Stefan; Cronin, Mark T; Edwards, Stephen W; de Knecht, Joop; Crofton, Kevin; Garcia-Reyero, Natalia; Hartung, Thomas; Worth, Andrew; Patlewicz, Grace

    2014-12-01

    Chemical regulation is challenged by the large number of chemicals requiring assessment for potential human health and environmental impacts. Current approaches are too resource intensive in terms of time, money and animal use to evaluate all chemicals under development or already on the market. The need for timely and robust decision making demands that regulatory toxicity testing becomes more cost-effective and efficient. One way to realize this goal is by being more strategic in directing testing resources; focusing on chemicals of highest concern, limiting testing to the most probable hazards, or targeting the most vulnerable species. Hypothesis driven Integrated Approaches to Testing and Assessment (IATA) have been proposed as practical solutions to such strategic testing. In parallel, the development of the Adverse Outcome Pathway (AOP) framework, which provides information on the causal links between a molecular initiating event (MIE), intermediate key events (KEs) and an adverse outcome (AO) of regulatory concern, offers the biological context to facilitate development of IATA for regulatory decision making. This manuscript summarizes discussions at the Workshop entitled "Advancing AOPs for Integrated Toxicology and Regulatory Applications" with particular focus on the role AOPs play in informing the development of IATA for different regulatory purposes. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. In situ vitrification engineering-scale test ES-INEL-5 test plan

    International Nuclear Information System (INIS)

    Stoots, P.R.

    1990-06-01

    In 1952, the Radioactive Waste Management Complex (RWMC) was established at the Idaho National Engineering Laboratory (INEL). RWMC is located on approximately 144 acres in the southwestern corner of the INEL site and was established as a controlled area for the burial of solid low-level wastes generated by INEL operations. In 1954, the 88-acre Subsurface Disposal Area (SDA) of RWMC began accepting solid transuranic-contaminated waste. From 1954 to 1970, transuranic-contaminated waste was accepted from the Rocky Flats Plant (RFP) near Golden, CO, as well as from other US Department of Energy (DOE) locations. In 1987, the Buried Waste Program (BWP) was established by EG ampersand G Idaho, Inc., the prime contractor at INEL. Following the Environmental Restoration guidelines of the Buried Waste Program, the In Situ Vitrification Program is participating in a Remedial Investigation/Feasibility Study (RI/FS) for permanent disposal of INEL waste, in compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). This study was requested and is being funded by the Office of Technology Development of the Idaho Operations Office of DOE (DOE-ID). As part of the RI/FS, an in situ vitrification (ISV) scoping study on the treatability of mixed low-level and mixed transuranic-contaminated waste is being performed to determine applicability of ISV to remediation of waste at SDA. This In Situ Vitrification Engineering-Scale Test ES-INEL-5 Test Plan considers the data needs of engineering, regulatory, health, and safety activities for all sampling and analysis activities in support of engineering scale test ES-INEL-5. 5 refs., 3 figs., 4 tabs

  11. Spent nuclear fuel integrity during dry storage - performance tests and demonstrations

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Doherty, A.L.

    1997-06-01

    This report summarizes the results of fuel integrity surveillance determined from gas sampling during and after performance tests and demonstrations conducted from 1983 through 1996 by or in cooperation with the US DOE Office of Commercial Radioactive Waste Management (OCRWM). The cask performance tests were conducted at Idaho National Engineering Laboratory (INEL) between 1984 and 1991 and included visual observation and ultrasonic examination of the condition of the cladding, fuel rods, and fuel assembly hardware before dry storage and consolidation of fuel, and a qualitative determination of the effects of dry storage and fuel consolidation on fission gas release from the spent fuel rods. The performance tests consisted of 6 to 14 runs involving one or two loading, usually three backfill environments (helium, nitrogen, and vacuum backfills), and one or two storage system orientations. The nitrogen and helium backfills were sampled and analyzed to detect leaking spent fuel rods. At the end of each performance test, periodic gas sampling was conducted on each cask. A spent fuel behavior project (i.e., enhanced surveillance, monitoring, and gas sampling activities) was initiated by DOE in 1994 for intact fuel in a CASTOR V/21 cask and for consolidated fuel in a VSC-17 cask. The results of the gas sampling activities are included in this report. Information on spent fuel integrity is of interest in evaluating the impact of long-term dry storage on the behavior of spent fuel rods. Spent fuel used during cask performance tests at INEL offers significant opportunities for confirmation of the benign nature of long-term dry storage. Supporting cask demonstration included licensing and operation of an independent spent fuel storage installation (ISFSI) at the Virginia Power (VP) Surry reactor site. A CASTOR V/21, an MC-10, and a Nuclear Assurance NAC-I28 have been loaded and placed at the VP ISFSI as part of the demonstration program. 13 refs., 14 figs., 9 tabs

  12. Longitudinal and Integrative Tests of Family Stress Model Effects on Mexican-Origin Adolescents

    Science.gov (United States)

    White, Rebecca M. B.; Liu, Yu; Nair, Rajni L.; Tein, Jenn-Yun

    2015-01-01

    The family stress model represents a common framework through which to examine the effects of environmental stressors on adolescent adjustment. The model suggests that economic and neighborhood stressors influence youth adjustment via disruptions to parenting. Incorporating integrative developmental theory, we examined the degree to which parents’ cultural value orientations mitigated the effects of stressors on parenting disruptions and the degree to which environmental adversity qualified the effect of parenting on adolescent adjustment. We tested the hypothesized Integrative Family Stress Model longitudinally in a sample of mother-youth dyads (N = 749) and father-youth dyads (N = 467) from Mexican origin families, across three times points spanning early to middle adolescence. Providing the first longitudinal evidence of family stress mediated effects, mothers’ perceptions of economic pressure were associated with increases in adolescent externalizing symptoms five years later via intermediate increases in harsh parenting. The remaining findings supported the notion that integrative developmental theory can inform family stress model hypothesis testing that is culturally and contextually relevant for wide range of diverse families and youth. For example, fathers’ perceptions of economic pressure and neighborhood danger had important implications for adolescent internalizing, via reductions in paternal warmth, but only at certain levels of neighborhood adversity. Mothers’ familism value orientations mitigated the effects of economic pressure on maternal warmth, protecting their adolescents from experiencing developmental costs associated with environmental stressors. Results are discussed in terms of identifying how integrative developmental theory intersects with the family stress model to set diverse youth on different developmental pathways. PMID:25751100

  13. Integrated sample-to-detection chip for nucleic acid test assays.

    Science.gov (United States)

    Prakash, R; Pabbaraju, K; Wong, S; Tellier, R; Kaler, K V I S

    2016-06-01

    Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.

  14. Integration of orthographic, conceptual, and episodic information on implicit and explicit tests.

    Science.gov (United States)

    Weldon, M S; Massaro, D W

    1996-03-01

    An experiment was conducted to determine how orthographic and conceptual information are integrated during incidental and intentional retrieval. Subjects studied word lists with either a shallow (counting vowels) or deep (rating pleasantness) processing task, then received either an implicit or explicit word fragment completion (WFC) test. At test, word fragments contained 0, 1, 2, or 4 letters, and were accompanied by 0, 1, 2, or 3 semantically related words. On both the implicit and explicit tests, performance improved with increases in the numbers of letters and words. When semantic cues were presented with the word fragments, the implicit test became more conceptually drive. Still, conceptual processing had a larger effect in intentional than in incidental retrieval. The Fuzzy Logical Model of Perception (FLMP) provided a good description of how orthographic, semantic, and episodic information were combined during retrieval.

  15. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    International Nuclear Information System (INIS)

    Boeser, C; Chwalek, T; Giffels, M; Kuznetsov, V; Wildish, T

    2014-01-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future. The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services. It allows cross-system integration tests of all three components to be performed in controlled environments, without interfering with production services. In this paper we discuss the design and implementation of the LifeCycle agent. We describe how it is used for small-scale debugging and validation tests, and how we extend that to large-scale tests of whole groups of sub-systems. We show how the LifeCycle agent can emulate the action of operators, physicists, or software agents external to the system under test, and how it can be scaled to large and complex systems.

  16. Integration and validation testing for PhEDEx, DBS and DAS with the PhEDEx LifeCycle agent

    Science.gov (United States)

    Boeser, C.; Chwalek, T.; Giffels, M.; Kuznetsov, V.; Wildish, T.

    2014-06-01

    The ever-increasing amount of data handled by the CMS dataflow and workflow management tools poses new challenges for cross-validation among different systems within CMS experiment at LHC. To approach this problem we developed an integration test suite based on the LifeCycle agent, a tool originally conceived for stress-testing new releases of PhEDEx, the CMS data-placement tool. The LifeCycle agent provides a framework for customising the test workflow in arbitrary ways, and can scale to levels of activity well beyond those seen in normal running. This means we can run realistic performance tests at scales not likely to be seen by the experiment for some years, or with custom topologies to examine particular situations that may cause concern some time in the future. The LifeCycle agent has recently been enhanced to become a general purpose integration and validation testing tool for major CMS services. It allows cross-system integration tests of all three components to be performed in controlled environments, without interfering with production services. In this paper we discuss the design and implementation of the LifeCycle agent. We describe how it is used for small-scale debugging and validation tests, and how we extend that to large-scale tests of whole groups of sub-systems. We show how the LifeCycle agent can emulate the action of operators, physicists, or software agents external to the system under test, and how it can be scaled to large and complex systems.

  17. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    International Nuclear Information System (INIS)

    Read, Rodney S.

    2011-07-01

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  18. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    Energy Technology Data Exchange (ETDEWEB)

    Read, Rodney S. (RSRead Consulting Inc. (Canada))

    2011-07-15

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  19. Does shaping bring an advantage for reversed field pinch plasmas?

    International Nuclear Information System (INIS)

    Guo, S.C.; Xu, X.Y.; Wang, Z.R.; Liu, Y.Q.

    2013-01-01

    The MHD–kinetic hybrid toroidal stability code MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) is applied to study the shaping effects on magnetohydrodynamic (MHD) stabilities in reversed field pinch (RFP) plasmas, where both elongation and triangularity are taken into account. The ideal wall β (the ratio of the gaso-kinetic to magnetic pressures) limit set by the ideal kink mode/resistive wall mode in shaped RFP is investigated first, followed by a study of the kinetic damping on the resistive wall mode. Physics understanding of the results is provided by a systematic numerical analysis. Furthermore, the stability boundary of the linear resistive tearing mode in shaped RFP plasmas is computed and compared with that of the circular case. Finally, bootstrap currents are calculated for both circular and shaped RFP plasmas. Overall, the results of these studies indicate that the current circular cross-section is an appropriate choice for RFP devices, in the sense that the plasma shaping does not bring an appreciable advantage to the RFP performance in terms of macroscopic stabilities. In order to reach a steady-state operation, future RFP fusion reactors will probably need a substantial fraction of external current drives, due to the unfavourable scaling for the plasma-generated bootstrap current in the RFP configuration. (paper)

  20. Integrated corridor management initiative : demonstration phase evaluation, San Diego technical capability analysis test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Technical Capability Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM proje...

  1. Confinement dynamics in the reversed field pinch

    International Nuclear Information System (INIS)

    Schoenberg, K.F.

    1988-01-01

    The study of basic transport and confinement dynamics is central to the development of the reversed field pinch (RFP) as a confinement concept. Thus, the goal of RFP research is to understand the connection between processes that sustain the RFP configuration and related transport/confinement properties. Recently, new insights into confinement have emerged from a detailed investigation of RFP electron and ion physics. These insights derive from the recognition that both magnetohydrodynamic (MHD) and electron kinetic effects play an important and strongly coupled role in RFP sustainment and confinement dynamics. In this paper, we summarize the results of these studies on the ZT-40M experiment. 8 refs

  2. EBR-2 [Experimental Breeder Reactor-2], IFR [Integral Fast Reactor] prototype testing programs

    International Nuclear Information System (INIS)

    Lehto, W.K.; Sackett, J.I.; Lindsay, R.W.; Planchon, H.P.; Lambert, J.D.B.

    1990-01-01

    The Experimental Breeder Reactor-2 (EBR-2) is a sodium cooled power reactor supplying about 20 MWe to the Idaho National Engineering Laboratory (INEL) grid and, in addition, is the key component in the development of the Integral Fast Reactor (IFR). EBR-2's testing capability is extensive and has seen four major phases: (1) demonstration of LMFBR power plant feasibility, (2) irradiation testing for fuel and material development. (3) testing the off-normal performance of fuel and plant systems and (4) operation as the IFR prototype, developing and demonstrating the IFR technology associated with fuel and plant design. Specific programs being carried out in support of the IFR include advanced fuels and materials development and component testing. This paper discusses EBR-2 as the IFR prototype and the associated testing programs. 29 refs

  3. Integrated vehicle-based safety systems light-vehicle field operational test, methodology and results report.

    Science.gov (United States)

    2010-12-01

    "This document presents the methodology and results from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michi...

  4. Tests and final integration of the ATLAS semiconductor tracker

    CERN Document Server

    Mikulec, Bettina

    2005-01-01

    The Silicon Tracker (SCT) is part of the Inner Detector at the ATLAS experiment at CERN. Its basic building blocks are 5 different types of silicon strip modules. In total more than 15000 p-on-n single-sided silicon strip sensors of an area of about 61 m2 were used to produce 4088 SCT modules. An overall module production yield of 92% could be achieved, where the silicon modules comply with the tight electrical, thermal and mechanical specifications. The macro-assembly of 2112 barrel modules to the four barrel support cylinders was successfully carried out. The nine disks of one endcap are fully populated with 988 modules, and for the second endcap more than 50% of the modules are already mounted. Test results operating complete barrels will be presented as well as a description of the test setup. The different integration steps of the SCT with the surrounding Transition Radiation Tracker (TRT) will be explained. The installation of SCT and TRT into the ATLAS pit will happen during 2006.

  5. System integration and performance of the EUV engineering test stand

    International Nuclear Information System (INIS)

    Tichenor, Daniel A.; Ray-Chaudhuri, Avijit K.; Replogle, William C.; Stulen, Richard H.; Kubiak, Glenn D.; Rockett, Paul D.; Klebanoff, Leonard E.; Jefferson, Karen L.; Leung, Alvin H.; Wronosky, John B.; Hale, Layton C.; Chapman, Henry N.; Taylor, John S.; Folta, James A.; Montcalm, Claude; Soufli, Regina; Spiller, Eberhard; Blaedel, Kenneth; Sommargren, Gary E.; Sweeney, Donald W.; Naulleau, Patrick; Goldberg, Kenneth A.; Gullikson, Eric M.; Bokor, Jeffrey; Batson, Phillip J.; Attwood, David T.; Jackson, Keith H.; Hector, Scott D.; Gwyn, Charles W.; Yan, Pei-Yang; Yan, P.

    2001-01-01

    The Engineering Test Stand (ETS) is a developmental lithography tool designed to demonstrate full-field EUV imaging and provide data for commercial-tool development. In the first phase of integration, currently in progress, the ETS is configured using a developmental projection system, while fabrication of an improved projection system proceeds in parallel. The optics in the second projection system have been fabricated to tighter specifications for improved resolution and reduced flare. The projection system is a 4-mirror, 4x-reduction, ring-field design having a numeral aperture of 0.1, which supports 70 nm resolution at a k 1 of 0.52. The illuminator produces 13.4 nm radiation from a laser-produced plasma, directs the radiation onto an arc-shaped field of view, and provides an effective fill factor at the pupil plane of 0.7. The ETS is designed for full-field images in step-and-scan mode using vacuum-compatible, magnetically levitated, scanning stages. This paper describes system performance observed during the first phase of integration, including static resist images of 100 nm isolated and dense features

  6. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2000-01-01

    Software test is the important stage in software process. The has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test class method based on interface object. In this method a set of basic test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  7. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2001-01-01

    Software test is the important stage in software process. There has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test-class method based on interface object. A set of basis test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  8. On a revisit to the Painlevé test for integrability and exact solutions ...

    Indian Academy of Sciences (India)

    ... the same equations and keeping the singularity manifold completely general in nature. It has been found that the equations, in real form, pass the Painlevé test for integrability. The truncation procedure of the same analysis leads to non-trivial exact solutions obtained previously and auto-Backlund transformation between ...

  9. RF and microwave integrated circuit development technology, packaging and testing

    CERN Document Server

    Gamand, Patrice; Kelma, Christophe

    2018-01-01

    RF and Microwave Integrated Circuit Development bridges the gap between existing literature, which focus mainly on the 'front-end' part of a product development (system, architecture, design techniques), by providing the reader with an insight into the 'back-end' part of product development. In addition, the authors provide practical answers and solutions regarding the choice of technology, the packaging solutions and the effects on the performance on the circuit and to the industrial testing strategy. It will also discuss future trends and challenges and includes case studies to illustrate examples. * Offers an overview of the challenges in RF/microwave product design * Provides practical answers to packaging issues and evaluates its effect on the performance of the circuit * Includes industrial testing strategies * Examines relevant RF MIC technologies and the factors which affect the choice of technology for a particular application, e.g. technical performance and cost * Discusses future trends and challen...

  10. Trial of prestressed concrete cable testing by sonic integrity tester

    International Nuclear Information System (INIS)

    Sugimoto, Masanobu

    1997-01-01

    Highway road network of Japan is in good condition. Those roads were constructed as social infrastructures. But some damages were occurred and propagated in concrete structure which passed more than 20 years after construction. As for the damages load caring capacity of bridge was decreased due to fatigue of increasing traffics and bridge vibration. Recently many troubles happened in PC structure as cut off of the main cables by corrosion and flying the non-grouting PC-bar to roadside. Some case can be checked by hammering testing method and X-ray photo cut or not and condition of cement grouting. But another case has not checking method. Now we are testing for the PC cables by sonic integrity tester which is modified from FPDS(Foundation Pile Diagnosis System). We report in this paper on this result and scope of the future of this method.

  11. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hwang; Ryu, Sung Uk; Yi, Sung Jae; Park, Hyun Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Dong Eok [Dept. of Precision Mechanical Engineering, Kyungpook National University, Sangju (Korea, Republic of)

    2017-08-15

    Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

  12. Analytic solutions of del x B = αB in a straight cylinder with α = α(r)

    International Nuclear Information System (INIS)

    Ling, K.M.; Baker, D.A.

    1985-06-01

    Analytic solutions of del x B = αB are presented for reversed field pinch (RFP) configurations in a straight cylinder with α = α(r) where r is the radial coordinate. The function α(r) is a smooth function of r vanishing at the wall (r = a). Closed form parametric formulas for a family of F-THETA curves are obtained from the analytic, cylindrically symmetric, force-free fields. These formulas can be used to fit experimental F-THETA curves and hence facilitate comparison between the various existing RFP experiments. The advantage of these formulas lies in the fact that they are expressed in terms of easily obtainable Bessel functions of the first kind, eliminating the need of mumerical integration. Results of the least-square fits of two typical ZT-40M shots are presented

  13. A red fluorescent nude mouse model of human endometriosis: advantages of a non-invasive imaging method.

    Science.gov (United States)

    Wang, Ningning; Hong, Shanshan; Tan, Jinfeng; Ke, Peiqi; Liang, Lili; Fei, Hui; Liu, Bin; Liu, Liqun; Liu, Yongdong; Yu, Bingjun

    2014-05-01

    To establish red fluorescent human endometriosis lesions in a nude mouse model and dynamically and non-invasively to compare intraperitoneal and subcutaneous injection models. Primary cultures of endometrial stromal cells (ESCs) and epithelial cells (EECs) isolated from 24 patients with a normal uterine cavity were transfected with 2.5×10(8) (Group 1) and 1.25×10(8) (Group 2) plaque-forming units (PFU) of adenovirus encoding red fluorescent protein (Ad-RFP). Transfection efficiencies, fluorescence intensity and apoptosis rate of the two types of cells were compared in vitro. A mixture of 2.5×10(8) PFU Ad-RFP-infected approximately 400 EECs cell mass and 2×10(6) ESCs for 36h was injected individually into 24 female nude mice subcutaneously (Group A) or intraperitoneally (Group B). From Day 5 after injection, an in vivo imaging system (IVIS) was used to non-invasively observe and compare the lesions of the two groups every week until Day 33. Specifically, the fluorescent intensity, positive rates, persistence time and lesion weight in the implanted human endometriosis lesions were compared. A parametric Student's t-test and two-way analysis of variance were used for statistical analysis. Compared with 1.25×10(8) PFU RFP, a titre of 2.5×10(8) PFU RFP ESCs and EECs incubated for 36h exhibited higher transfection efficiencies and higher fluorescence intensities in vitro. In vivo imaging of the fluorescent human endometriosis lesions originating from an RFP titre of 2.5×10(8) PFU showed that the intensity and lesion weight in Group A were significantly higher than in Group B. However, the two groups had the same RFP-positive rates and fluorescence persistence. The structure of each lesion was evaluated by immunohistochemistry to confirm its human endometrial origin. The red fluorescent human endometriosis model established by subcutaneously injecting 2.5×10(8) PFU RFP-transfected stromal cells and epithelial cells into nude mice had a higher fluorescent positive

  14. Bio-testing integral toxicity of corrosion inhibitors, biocides and oil hydrocarbons in oil-and gas-processing industry

    Energy Technology Data Exchange (ETDEWEB)

    Chugunov, V.A.; Kholodenko, V.P.; Irkhina, I.A.; Fomchenkov, V.M.; Novikov, I.A. [State Research Center for Applied Microbiology, Obolensk, Moscow (Russian Federation)

    2004-07-01

    In recent years bioassays have been widely used for assessing levels of contamination of the environment. This is due to the fact that test-organisms provide a general response to toxicants present in samples. Based on microorganisms as test objects, it is possible to develop cheap, sensitive and rapid assays to identify environmental xenobiotics and toxicants. The objective of the research was to develop different microbiological assays for assessing integral toxicity of water environments polluted with corrosion inhibitors, biocides and hydrocarbons in oil- and gas-processing industry. Bio-luminescent, electro-orientational, osmo-optic and microorganism reducing activity assays were used for express evaluation of integral toxicity. They are found to determine promptly integral toxicity of water environments containing various pollutants (oil, oil products, corrosion inhibitors, biocides). Results conclude that the assays may be used for analyzing integral toxicity of water polluted with hydrocarbons, as well as for monitoring of water changes as a result of biodegradation of pollutants by microorganisms and their associations. Using a kit of different assays, it is also possible to evaluate ecological safety of biocides, corrosion inhibitors, and their compositions. Bioassays used as a kit are more effective than each assay individually, allowing one to get complete characterization of a reaction of bacterial test organisms to different environments. (authors)

  15. Model-based integration and testing : bridging the gap between academic theory and industrial practice

    NARCIS (Netherlands)

    Braspenning, N.C.W.M.

    2008-01-01

    For manufacturers of high-tech multi-disciplinary systems such as semiconductor equipment, the effort required for integration and system testing is ever increasing, while customers demand a shorter time-to-market.This book describes how executable models can replace unavailable component

  16. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  17. Red fluorescence of dental plaque in children -A cross-sectional study.

    Science.gov (United States)

    Volgenant, Catherine M C; Zaura, Egija; Brandt, Bernd W; Buijs, Mark J; Tellez, Marisol; Malik, Gayatri; Ismail, Amid I; Ten Cate, Jacob M; van der Veen, Monique H

    2017-03-01

    The relation between the presence of red fluorescent plaque and the caries status in children was studied. In addition, the microbial composition of dental plaque from sites with red fluorescent plaque (RFP) and from sites with no red fluorescent plaque (NFP) was assessed. Fluorescence photographs were taken from fifty children (6-14 years old) with overnight plaque. Full-mouth caries scores (ICDAS II) were obtained. The composition of a saliva sample and two plaque samples (RFP and NFP) was assessed using 16S rDNA sequencing. At the site level, no clinically relevant correlations were found between the presence of RFP and the caries status. At the subject level, a weak correlation was found between RFP and the caries status when non-cavitated lesions were included (r s =0.37, p=0.007). The microbial composition of RFP differed significantly from NFP. RFP had more anaerobes and more Gram-negative bacterial taxa. The most discriminative operational taxonomic units (OTUs) for RFP were Corynebacterium, Leptotrichia, Porphyromonas and Selenomonas, while the most discriminative OTUs for NFP were Neisseria, Actinomyces, Streptococcus and Rothia. There were no clinical relevant correlations in this cross-sectional study between the presence of RFP and (early) caries lesions. There were differences in the composition of these phenotypically different plaque samples: RFP contained more Gram-negative, anaerobic taxa and was more diverse than NFP. The study outcomes provide more insight in the possibilities to use plaque fluorescence in oral health risk assessments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. W-026 acceptance test report system integration equipment (SIE)(submittal {number_sign} 018.6.A)

    Energy Technology Data Exchange (ETDEWEB)

    Watson, T.L.

    1997-01-27

    Acceptance testing of the System Integration Equipment (SIE) at Hanford was performed in two stages. The first was inconclusive, and resulted in a number of findings. These finding. are summarized as part of this report. The second stage of testing addressed these findings, and performed full system testing per the approved test procedure. This report includes summaries of all testing, results and finding.. Although the SIE did not in some cases perform as required for plant operations, it did perform per the system specification. (These discrepancies were noted and are addressed elsewhere.) Following testing, the system was formaLLy accepted. Documentation of this acceptance is incLuded in this report.

  19. The Compact Ignition Tokamak

    International Nuclear Information System (INIS)

    Schmidt, J.

    1987-01-01

    The author discusses his lab's plan for completing the Compact Ignition Tokamak (CIT) conceptual design during calendar year 1987. Around July 1 they froze the subsystem envelopes on the device to continue with the conceptual design. They did this by formalizing a general requirements document. They have been developing the management plan and submitted a version to the DOE July 10. He describes a group of management activities. They released the vacuum vessel Request For Proposals (RFP) on August 5. An RFP to do a major part of the system engineering on the device is being developed. They intend to assemble the device outside of the test cell, then move it into the the test cell, install it there, and bring to the test cell many of the auxiliary facilities from TFTR, for example, power supplies

  20. Integrating Test-Form Formatting into Automated Test Assembly

    Science.gov (United States)

    Diao, Qi; van der Linden, Wim J.

    2013-01-01

    Automated test assembly uses the methodology of mixed integer programming to select an optimal set of items from an item bank. Automated test-form generation uses the same methodology to optimally order the items and format the test form. From an optimization point of view, production of fully formatted test forms directly from the item pool using…

  1. The Holistic Integrity Test (HIT - quantified resilience analysis

    Directory of Open Access Journals (Sweden)

    Dobson Mike

    2016-01-01

    Full Text Available The Holistic Integrity Test (HIT - Quantified Resilience Analysis. Rising sea levels and wider climate change mean we face an increasing risk from flooding and other natural hazards. Tough economic times make it difficult to economically justify or afford the desired level of engineered risk reduction. Add to this significant uncertainty from a range of future predictions, constantly updated with new science. We therefore need to understand not just how to reduce the risk, but what could happen should above design standard events occur. In flood terms this includes not only the direct impacts (damage and loss of life, but the wider cascade impacts to infrastructure systems and the longer term impacts on the economy and society. However, understanding the “what if” is only the first part of the equation; a range of improvement measures to mitigate such effects need to be identified and implemented. These measures should consider reducing the risk, lessening the consequences, aiding the response, and speeding up the recovery. However, they need to be objectively assessed through quantitative analysis, which underpins them technically and economically. Without such analysis, it cannot be predicted how measures will perform if the extreme events occur. It is also vital to consider all possible hazards as measures for one hazard may hinder the response to another. The Holistic Integrity Test (HIT, uses quantitative system analysis and “HITs” the site, its infrastructure, contained dangers and wider regional system to determine how it copes with a range of severe shock events, Before, During and After the event, whilst also accounting for uncertainty (as illustrated in figure 1. First explained at the TINCE 2014 Nuclear Conference in Paris, it was explained in terms of a Nuclear Facility needing to analyse the site in response to post Fukushima needs; the hit is however universally applicable. The HIT has three key risk reduction goals: The

  2. Power Systems Integration Laboratory | Energy Systems Integration Facility

    Science.gov (United States)

    | NREL Power Systems Integration Laboratory Power Systems Integration Laboratory Research in the Energy System Integration Facility's Power Systems Integration Laboratory focuses on the microgrid applications. Photo of engineers testing an inverter in the Power Systems Integration Laboratory

  3. Non-animal assessment of skin sensitization hazard: Is an integrated testing strategy needed, and if so what should be integrated?

    Science.gov (United States)

    Roberts, David W; Patlewicz, Grace

    2018-01-01

    There is an expectation that to meet regulatory requirements, and avoid or minimize animal testing, integrated approaches to testing and assessment will be needed that rely on assays representing key events (KEs) in the skin sensitization adverse outcome pathway. Three non-animal assays have been formally validated and regulatory adopted: the direct peptide reactivity assay (DPRA), the KeratinoSens™ assay and the human cell line activation test (h-CLAT). There have been many efforts to develop integrated approaches to testing and assessment with the "two out of three" approach attracting much attention. Here a set of 271 chemicals with mouse, human and non-animal sensitization test data was evaluated to compare the predictive performances of the three individual non-animal assays, their binary combinations and the "two out of three" approach in predicting skin sensitization potential. The most predictive approach was to use both the DPRA and h-CLAT as follows: (1) perform DPRA - if positive, classify as sensitizing, and (2) if negative, perform h-CLAT - a positive outcome denotes a sensitizer, a negative, a non-sensitizer. With this approach, 85% (local lymph node assay) and 93% (human) of non-sensitizer predictions were correct, whereas the "two out of three" approach had 69% (local lymph node assay) and 79% (human) of non-sensitizer predictions correct. The findings are consistent with the argument, supported by published quantitative mechanistic models that only the first KE needs to be modeled. All three assays model this KE to an extent. The value of using more than one assay depends on how the different assays compensate for each other's technical limitations. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Testing market integration for Kenyan pineapples. | Onyuma ...

    African Journals Online (AJOL)

    The market structure was found to be oligopsonistic in nature with aspects of collusion amongst the urban middlemen and local market traders thus barring further entry by other potential actors. There was little market integration between urban markets and producing markets, and very low or no integration between the ...

  5. Evaluating the validity of an integrity-based situational judgement test for medical school admissions.

    Science.gov (United States)

    Husbands, Adrian; Rodgerson, Mark J; Dowell, Jon; Patterson, Fiona

    2015-09-02

    While the construct of integrity has emerged as a front-runner amongst the desirable attributes to select for in medical school admissions, it is less clear how best to assess this characteristic. A potential solution lies in the use of Situational Judgement Tests (SJTs) which have gained popularity due to robust psychometric evidence and potential for large-scale administration. This study aims to explore the psychometric properties of an SJT designed to measure the construct of integrity. Ten SJT scenarios, each with five response stems were developed from critical incident interviews with academic and clinical staff. 200 of 520 (38.5 %) Multiple Mini Interview candidates at Dundee Medical School participated in the study during the 2012-2013 admissions cycle. Participants were asked to rate the appropriateness of each SJT response on a 4-point likert scale as well as complete the HEXACO personality inventory and a face validity questionnaire. Pearson's correlations and descriptive statistics were used to examine the associations between SJT score, HEXACO personality traits, pre-admissions measures namely academic and United Kingdom Clinical Aptitude Test (UKCAT) scores, as well as acceptability. Cronbach's alpha reliability for the SJT was .64. Statistically significant correlations ranging from .16 to .36 (.22 to .53 disattenuated) were observed between SJT score and the honesty-humility (integrity), conscientiousness, extraversion and agreeableness dimensions of the HEXACO inventory. A significant correlation of .32 (.47 disattenuated) was observed between SJT and MMI scores and no significant relationship with the UKCAT. Participant reactions to the SJTs were generally positive. Initial findings are encouraging regarding the psychometric robustness of an integrity-based SJT for medical student selection, with significant associations found between the SJTs, integrity, other desirable personality traits and the MMI. The SJTs showed little or no redundancy with

  6. The development of functional requirement for integrated test facility

    International Nuclear Information System (INIS)

    Sim, B.S.; Oh, I.S.; Cha, K.H.; Lee, H.C.

    1994-01-01

    An Integrated Test Facility (ITF) is a human factors experimental environment comprised of a nuclear power plant function simulator, man-machine interfaces (MMI), human performance recording systems, and signal control and data analysis systems. In this study, we are going to describe how the functional requirements are developed by identification of both the characteristics of generic advanced control rooms and the research topics of world-wide research interest in human factors community. The functional requirements of user interface developed in this paper together with those of the other elements will be used for the design and implementation of the ITF which will serve as the basis for experimental research on a line of human factors topics. (author). 15 refs, 1 fig

  7. Metabologenomics of Phaeochromocytoma and Paraganglioma: An Integrated Approach for Personalised Biochemical and Genetic Testing.

    Science.gov (United States)

    Eisenhofer, Graeme; Klink, Barbara; Richter, Susan; Lenders, Jacques Wm; Robledo, Mercedes

    2017-04-01

    The tremendous advances over the past two decades in both clinical genetics and biochemical testing of chromaffin cell tumours have led to new considerations about how these aspects of laboratory medicine can be integrated to improve diagnosis and management of affected patients. With germline mutations in 15 genes now identified to be responsible for over a third of all cases of phaeochromocytomas and paragangliomas, these tumours are recognised to have one of the richest hereditary backgrounds among all neoplasms. Depending on the mutation, tumours show distinct differences in metabolic pathways that relate to or even directly impact clinical presentation. At the same time, there has been improved understanding about how catecholamines are synthesised, stored, secreted and metabolised by chromaffin cell tumours. Although the tumours may not always secrete catecholamines it has become clear that almost all continuously produce and metabolise catecholamines. This has not only fuelled changes in laboratory medicine, but has also assisted in recognition of genotype-biochemical phenotype relationships important for diagnostics and clinical care. In particular, differences in catecholamine and energy pathway metabolomes can guide genetic testing, assist with test interpretation and provide predictions about the nature, behaviour and imaging characteristics of the tumours. Conversely, results of genetic testing are important for guiding how routine biochemical testing should be employed and interpreted in surveillance programmes for at-risk patients. In these ways there are emerging needs for modern laboratory medicine to seamlessly integrate biochemical and genetic testing into the diagnosis and management of patients with chromaffin cell tumours.

  8. The influence of chemistry on severe accident phenomena in integral tests

    International Nuclear Information System (INIS)

    Hobbins, R.R.; Osetek, D.J.; Hagrman, D.L.

    1988-01-01

    The influence of chemical processes on severe accident phenomena in integral tests is reviewed and recommendations for areas of additional work are made. The results reviewed include those from tests conducted in the in-pile facilities at ACRR, PBF, and TREAT and the TMI-2 accident. Progress has been made in understanding the influence of chemistry on important severe accident phenomena such as core melt progression, hydrogen generation, aerosol generation and transport, and fission product release and transport (including revaporization). An example is the chemistry of volatile fission products, especially iodine and tellurium. Areas where understanding is inadequate are also apparent, such as chemical interactions between fission product vapors and aerosols. Influential chemical processes reviewed include oxidation by steam and interactions among control, structural, fuel, fission product, and aerosol materials

  9. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    Directory of Open Access Journals (Sweden)

    Hwang Bae

    2017-08-01

    Full Text Available Three small-break loss-of-coolant accident (SBLOCA tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor, i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

  10. Integrated vehicle-based safety systems (IVBSS) : light vehicle platform field operational test data analysis plan.

    Science.gov (United States)

    2009-12-22

    This document presents the University of Michigan Transportation Research Institutes plan to : perform analysis of data collected from the light vehicle platform field operational test of the : Integrated Vehicle-Based Safety Systems (IVBSS) progr...

  11. Integrated vehicle-based safety systems (IVBSS) : heavy truck platform field operational test data analysis plan.

    Science.gov (United States)

    2009-11-23

    This document presents the University of Michigan Transportation Research Institutes plan to perform : analysis of data collected from the heavy truck platform field operational test of the Integrated Vehicle- : Based Safety Systems (IVBSS) progra...

  12. Basic tests on integrity evaluation for natural hexafluoride transporting container

    International Nuclear Information System (INIS)

    Gomi, Yoshio; Yamakawa, Hidetsugu; Kato, Osamu; Kobayashi, Seiichi

    1990-01-01

    In this study, the affected factors that needed to integrity evaluation for UF 6 transporting 48Y cylinder, were confirmed by basic tests and preliminary analysis. The factors were the sealing parts and external surface emissivity that ruled both the behavior under fire accident condition and the fire resistance capability of the cylinder, and the external pressure resistance capability at the sunk accident. The results obtained as follows. (1) Confirming tests for fire resistance of cylinder valve and plug, seat leakage of the valve caused at 150 degrees C. by unequal thermal expansion between the valve body and the stem. The tin-lead solder coating the tapered thread of valve and plug, melted at 200 degrees C., then the sealing boundary broke. (2) An external emissivity influence to radiation heat transfer measured with test pieces heated by electric oven. The covered paints of the specimen burned and separated, the emissivity changed 0.4 to 0.6, dependent on the surrounding temperature. Type 48Y cylinder filled with 12.5 tons of UF 6 and the measured emissivity was used the computer code analysis. The hydraulic breaking did not happen under the fire accident condition at 800 degrees C., for 30 minutes. (3) The external pressure test of the valve endured the hydrostatic pressure at 3000 meters, which corresponded to about five times the cylinder body buckling strength. (author)

  13. Behaviour of the peripheral plasma in the reversed field pinch

    International Nuclear Information System (INIS)

    Matsuoka, A.; Sato, K.I.; Arimoto, H.; Yamada, S.; Nagata, A.; Murata, H.

    1986-01-01

    By using Langmuir probes installed behind limiters, time behaviour of the peripheral plasma in the Reversed Field Pinch (RFP) are investigated. They are strongly affected by the confined RFP plasma and are divided into three phases (the initial phase before setting up the RFP configuration, the current rising phase, and the quiescent phase), which are just the same as those of the confined RFP plasma. Typical behaviour of the peripheral plasma have relations to the pump out phenomena and of the toroidal flux generation. (author)

  14. Construction of a test platform for Test Blanket Module (TBM) systems integration and maintenance in ITER Port Cell #16

    Energy Technology Data Exchange (ETDEWEB)

    Vála, Ladislav, E-mail: ladislav.vala@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Reungoat, Mathieu, E-mail: mathieu.reungoat@cvrez.cz [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Vician, Martin [Centrum výzkumu Řež, Hlavní 130, 250 68 Husinec-Řež (Czech Republic); Poitevin, Yves; Ricapito, Italo; Zmitko, Milan; Panayotov, Dobromir [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • A non-nuclear, full size facility – TBM platform – is under construction in CVR. • It is designed for tests, optimization and validation of TBS maintenance operations. • It will allow testing and validation of specific maintenance tools and RH equipment. • It reproduces ITER Port Cell #16, as well as the TBS interfaces and main equipment. • The TBM platform will be available for full operation in the first half of 2016. - Abstract: This paper describes a project of a non-nuclear, 1:1 scale testing platform dedicated to tests, optimization and validation of integration and maintenance operations for the European TBM systems in the ITER Port Cell #16. This TBM platform is currently under construction in Centrum výzkumu Řež, Czech Republic. The facility is realized within the scope of the SUSEN project and its full operation is foreseen in the first half of 2016.

  15. Expression pattern of Ccr2 and Cx3cr1 in inherited retinal degeneration.

    Science.gov (United States)

    Kohno, Hideo; Koso, Hideto; Okano, Kiichiro; Sundermeier, Thomas R; Saito, Saburo; Watanabe, Sumiko; Tsuneoka, Hiroshi; Sakai, Tsutomu

    2015-10-12

    Though accumulating evidence suggests that microglia, resident macrophages in the retina, and bone marrow-derived macrophages can cause retinal inflammation which accelerates photoreceptor cell death, the details of how these cells are activated during retinal degeneration (RD) remain uncertain. Therefore, it is important to clarify which cells play a dominant role in fueling retinal inflammation. However, distinguishing between microglia and macrophages is difficult using conventional techniques such as cell markers (e.g., Iba-1). Recently, two mouse models for visualizing chemokine receptors were established, Cx3cr1 (GFP/GFP) and Ccr2 (RFP/RFP) mice. As Cx3cr1 is expressed in microglia and Ccr2 is reportedly expressed in activated macrophages, these mice have the potential to distinguish microglia and macrophages, yielding novel information about the activation of these inflammatory cells and their individual roles in retinal inflammation. In this study, c-mer proto-oncogene tyrosine kinase (Mertk) (-/-) mice, which show photoreceptor cell death due to defective retinal pigment epithelium phagocytosis, were employed as an animal model of RD. Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice were established by breeding Mertk (-/-) , Cx3cr1 (GFP/GFP) , and Ccr2 (RFP/RFP) mice. The retinal morphology and pattern of inflammatory cell activation and invasion of Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice were evaluated using retina and retinal pigment epithelium (RPE) flat mounts, retinal sections, and flow cytometry. Four-week-old Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice showed Cx3cr1-GFP-positive microglia in the inner retina. Cx3cr1-GFP and Ccr2-RFP dual positive activated microglia were observed in the outer retina and subretinal space of 6- and 8-week-old animals. Ccr2-RFP single positive bone marrow-derived macrophages were observed to migrate into the retina of Mertk (-/-) Cx3cr1 (GFP/+) Ccr2 (RFP/+) mice. These invading cells were still observed in the

  16. Integrated infrastructure initiatives for material testing reactor innovations

    International Nuclear Information System (INIS)

    Dekeyser, Jean; Vermeeren, Ludo; Iracane, Daniel

    2011-01-01

    Highlights: → The EU FP7 MTR+I3 project has initiated a durable cooperation between MTR operators. → Improvements in irradiation test device technology and instrumentation were achieved. → Professional training efforts were streamlined and best practices were exchanged. → A framework has been set up to coordinate and optimize the use of MTRs in the EU. - Abstract: The key goal of the European FP6 project MTR+I3 was to build a durable cooperation between Material Testing Reactor (MTR) operators and relevant laboratories that can maintain European leadership with updated capabilities and competences regarding reactor performances and irradiation technology. The MTR+I3 consortium was composed of 18 partners with a high level of expertise in irradiation-related services for all types of nuclear plants. This project covered activities that foster integration of the MTR community involved in designing, fabricating and operating irradiation devices through information exchange, know-how cross-fertilization, exchanges of interdisciplinary personnel, structuring of key-technology suppliers and professional training. The network produced best practice guidelines for selected irradiation activities. This project allowed to launch or to improve technical studies in various domains dealing with irradiation test device technology, experimental loop designs and instrumentation. Major results are illustrated in this paper. These concern in particular: on-line fuel power determination, neutron screen optimization, simulation of transmutation process, power transient systems, water chemistry and stress corrosion cracking, fission gas measurement, irradiation behaviour of electronic modules, mechanical loading under irradiation, high temperature gas loop technology, heavy liquid metal loop development and safety test instrumentation. One of the major benefits of this project is that, starting from a situation of fragmented resources in a strongly competitive sector, it has

  17. Comparison of thermo-hydraulic analysis with measurements for HELIOS. The scaled integral test loop for PEACER

    International Nuclear Information System (INIS)

    Cho, Jae Hyun; Lim, Jun; Kim, Ji Hak; Hwang, Il Soon

    2009-01-01

    A scaled-down Lead-Bismuth Eutectic circulating integral test loop named as HELIOS (Heavy Eutectic liquid metal Loop for Integral test of Operability and Safety of PEACER) has been employed to characterize steady-state isothermal forced circulation behavior and non-isothermal natural circulation capability of the lead and lead-alloy cooled advanced nuclear energy systems (LACANES). In this time, thermal-hydraulic experiments have been carried out using HELIOS following rigorous calibration campaigns on sensors for temperature and pressure, especially isothermal steady-state forced convection using by the pump. The isothermal steady-state forced convection test was performed to obtain the pressure loss information including friction loss coefficients and form loss coefficients. Then its data were compared with multi-approaching analysis including hand calculation results and computer simulation code results. (MARS-LBE, CFX). We report the results of comparisons between the analysis and measurements together. (author)

  18. NASA ERA Integrated CFD for Wind Tunnel Testing of Hybrid Wing-Body Configuration

    Science.gov (United States)

    Garcia, Joseph A.; Melton, John E.; Schuh, Michael; James, Kevin D.; Long, Kurt R.; Vicroy, Dan D.; Deere, Karen A.; Luckring, James M.; Carter, Melissa B.; Flamm, Jeffrey D.; hide

    2016-01-01

    NASAs Environmentally Responsible Aviation (ERA) Project explores enabling technologies to reduce aviations impact on the environment. One research challenge area for the project has been to study advanced airframe and engine integration concepts to reduce community noise and fuel burn. In order to achieve this, complex wind tunnel experiments at both the NASA Langley Research Centers (LaRC) 14x22 and the Ames Research Centers 40x80 low-speed wind tunnel facilities were conducted on a Boeing Hybrid Wing Body (HWB) configuration. These wind tunnel tests entailed various entries to evaluate the propulsion airframe interference effects including aerodynamic performance and aeroacoustics. In order to assist these tests in producing high quality data with minimal hardware interference, extensive Computational Fluid Dynamic (CFD) simulations were performed for everything from sting design and placement for both the wing body and powered ejector nacelle systems to the placement of aeroacoustic arrays to minimize its impact on the vehicles aerodynamics. This paper will provide a high level summary of the CFD simulations that NASA performed in support of the model integration hardware design as well as some simulation guideline development based on post-test aerodynamic data. In addition, the paper includes details on how multiple CFD codes (OVERFLOW, STAR-CCM+, USM3D, and FUN3D) were efficiently used to provide timely insight into the wind tunnel experimental setup and execution.

  19. UAS-NAS Flight Test Series 3: Test Environment Report

    Science.gov (United States)

    Hoang, Ty; Murphy, Jim; Otto, Neil

    2016-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communications (Comm), and Certification to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Detect and Avoid (DAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project is conducting a series of human-in-the-loop (HITL) and flight test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity, and

  20. Recognized focused practice: Does sub-specialty designation offer value to the neurosurgeon?

    Directory of Open Access Journals (Sweden)

    Maya A Babu

    Full Text Available Vehicles for life-long assessment such as Maintenance of Certification tend to focus on generalist neurosurgical knowledge. However, as neurosurgeons advance in their careers, they tend to narrow their practice and increase volumes in certain specific types of operations. Failing to test the type of procedures most relevant to the practitioner is a lost opportunity to improve the knowledge and practice of the individual neurosurgeon. In this study, we assess the neurosurgical community's appetite for designations of board-recognized Recognized Focused Practice (RFP. We administered a validated, online, confidential survey to 4,899 neurosurgeons (2,435 American Board of Neurological Surgery (ABNS Diplomates participating in MOC, 1,440 Diplomates certified prior to 1999 (grandfathered, and 1,024 retired Diplomates. We received 1,449 responses overall (30% response rate. A plurality of respondents were in practice 11-15 years (18.5%, in private practice (40% and participate in MOC (61%. 49% of respondents felt that a RFP designation would not be helpful. For the 30% who felt that RFP would be helpful, 61.3% felt that it would support recognition by their hospital or practice, it would motivate them to stay current on medical knowledge (53.4%, or it would help attract patients (46.4%;. The most popular suggestions for RFP were Spine (56.2%, Cerebrovascular (62.9%, Pediatrics (64.1%, and Functional/Stereotactic (52%. A plurality of neurosurgeons (35.7% felt that RFP should recognize neurosurgeons with accredited and non-accredited fellowship experience and sub-specialty experience. Ultimately, Recognized Focused Practice may provide value to individual neurosurgeons, but the neurosurgical community shows tepid interest for pursuing this designation.

  1. Recognized focused practice: Does sub-specialty designation offer value to the neurosurgeon?

    Science.gov (United States)

    Babu, Maya A; Liau, Linda M; Meyer, Fredric B

    2017-01-01

    Vehicles for life-long assessment such as Maintenance of Certification tend to focus on generalist neurosurgical knowledge. However, as neurosurgeons advance in their careers, they tend to narrow their practice and increase volumes in certain specific types of operations. Failing to test the type of procedures most relevant to the practitioner is a lost opportunity to improve the knowledge and practice of the individual neurosurgeon. In this study, we assess the neurosurgical community's appetite for designations of board-recognized Recognized Focused Practice (RFP). We administered a validated, online, confidential survey to 4,899 neurosurgeons (2,435 American Board of Neurological Surgery (ABNS) Diplomates participating in MOC, 1,440 Diplomates certified prior to 1999 (grandfathered), and 1,024 retired Diplomates). We received 1,449 responses overall (30% response rate). A plurality of respondents were in practice 11-15 years (18.5%), in private practice (40%) and participate in MOC (61%). 49% of respondents felt that a RFP designation would not be helpful. For the 30% who felt that RFP would be helpful, 61.3% felt that it would support recognition by their hospital or practice, it would motivate them to stay current on medical knowledge (53.4%), or it would help attract patients (46.4%;). The most popular suggestions for RFP were Spine (56.2%), Cerebrovascular (62.9%), Pediatrics (64.1%), and Functional/Stereotactic (52%). A plurality of neurosurgeons (35.7%) felt that RFP should recognize neurosurgeons with accredited and non-accredited fellowship experience and sub-specialty experience. Ultimately, Recognized Focused Practice may provide value to individual neurosurgeons, but the neurosurgical community shows tepid interest for pursuing this designation.

  2. Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

    Science.gov (United States)

    Dugala, Gina M.; Taylor, Linda M.; Bell, Mark E.; Dolce, James L.; Fraeman, Martin; Frankford, David P.

    2015-01-01

    NASA Glenn Research Center developed a nonnuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASCs), Dual Convertor Controller (DCC) EMs (engineering models) 2 and 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University Applied Physics Laboratory (JHU/APL) to actively control a pair of ASCs. The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS), which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and super-capacitor. A load profile, created based on data from several missions, tested the RPS's and RSIL's ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 volts or exceeded 36 volts. Once operation was verified with the DASCS, the tests were repeated with actual operating ASCs. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.

  3. UAS Integration in the NAS Project: Flight Test 3 Data Analysis of JADEM-Autoresolver Detect and Avoid System

    Science.gov (United States)

    Gong, Chester; Wu, Minghong G.; Santiago, Confesor

    2016-01-01

    The Unmanned Aircraft Systems Integration in the National Airspace System project, or UAS Integration in the NAS, aims to reduce technical barriers related to safety and operational challenges associated with enabling routine UAS access to the NAS. The UAS Integration in the NAS Project conducted a flight test activity, referred to as Flight Test 3 (FT3), involving several Detect-and-Avoid (DAA) research prototype systems between June 15, 2015 and August 12, 2015 at the Armstrong Flight Research Center (AFRC). This report documents the flight testing and analysis results for the NASA Ames-developed JADEM-Autoresolver DAA system, referred to as 'Autoresolver' herein. Four flight test days (June 17, 18, 22, and July 22) were dedicated to Autoresolver testing. The objectives of this test were as follows: 1. Validate CPA prediction accuracy and detect-and-avoid (DAA, formerly known as self-separation) alerting logic in realistic flight conditions. 2. Validate DAA trajectory model including maneuvers. 3. Evaluate TCAS/DAA interoperability. 4. Inform final Minimum Operating Performance Standards (MOPS). Flight test scenarios were designed to collect data to directly address the objectives 1-3. Objective 4, inform final MOPS, was a general objective applicable to the UAS in the NAS project as a whole, of which flight test is a subset. This report presents analysis results completed in support of the UAS in the NAS project FT3 data review conducted on October 20, 2015. Due to time constraints and, to a lesser extent, TCAS data collection issues, objective 3 was not evaluated in this analysis.

  4. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  5. Energy Systems Integration Facility Videos | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems Integration Facility Videos Energy Systems Integration Facility Integration Facility NREL + SolarCity: Maximizing Solar Power on Electrical Grids Redefining What's Possible for Renewable Energy: Grid Integration Robot-Powered Reliability Testing at NREL's ESIF Microgrid

  6. FDS5 Simulation of PRISME INTEGRAL Test, PRSINT4

    International Nuclear Information System (INIS)

    Park, Jong Seok

    2012-01-01

    The reliance on fire modeling has playing a key role in the risk-informed and performance-based fire protection field. The ability to accurately predict fire behavior using the fire models is of high utility for hazard assessment, investigations and performance based design. Validation is the process of determining the degree of agreement between fire model outputs and real world events for one or more results of interest. The goal of validation is to quantify confidence in the predictive capability of the model. Validation in NUREG-1824 entails comparing the model prediction with full-scale fire experiments and quantifying the results. The objectives of this study, focused on the fire model validation, are to compare the FDS5 prediction results with the PRISME INTEGRAL test data and to validate FDS5 model

  7. NSTAR Ion Thruster and Breadboard Power Processor Functional Integration Test Results

    Science.gov (United States)

    Hamley, John A.; Pinero, Luis R.; Rawlin, Vincent K.; Miller, John R.; Myers, Roger M.; Bowers, Glen E.

    1996-01-01

    A 2.3 kW Breadboard Power Processing Unit (BBPPU) was developed as part of the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) Program. The NSTAR program will deliver an electric propulsion system based on a 30 cm xenon ion thruster to the New Millennium (NM) program for use as the primary propulsion system for the initial NM flight. The final development test for the BBPPU, the Functional Integration Test, was carried out to demonstrate all aspects of BBPPU operation with an Engineering Model Thruster. Test objectives included: (1) demonstration and validation of automated thruster start procedures, (2) demonstration of stable closed loop control of the thruster beam current, (3) successful response and recovery to thruster faults, and (4) successful safing of the system during simulated spacecraft faults. These objectives were met over the specified 80-120 VDC input voltage range and 0.5-2.3 output power capability of the BBPPU. Two minor anomalies were noted in discharge and neutralizer keeper current. These anomalies did not affect the stability of the system and were successfully corrected.

  8. A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests

    International Nuclear Information System (INIS)

    Thien, Mike G.; Barnes, Steve M.

    2013-01-01

    The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described

  9. Application of Modal Parameter Estimation Methods for Continuous Wavelet Transform-Based Damage Detection for Beam-Like Structures

    Directory of Open Access Journals (Sweden)

    Zhi Qiu

    2015-02-01

    Full Text Available This paper presents a hybrid damage detection method based on continuous wavelet transform (CWT and modal parameter identification techniques for beam-like structures. First, two kinds of mode shape estimation methods, herein referred to as the quadrature peaks picking (QPP and rational fraction polynomial (RFP methods, are used to identify the first four mode shapes of an intact beam-like structure based on the hammer/accelerometer modal experiment. The results are compared and validated using a numerical simulation with ABAQUS software. In order to determine the damage detection effectiveness between the QPP-based method and the RFP-based method when applying the CWT technique, the first two mode shapes calculated by the QPP and RFP methods are analyzed using CWT. The experiment, performed on different damage scenarios involving beam-like structures, shows that, due to the outstanding advantage of the denoising characteristic of the RFP-based (RFP-CWT technique, the RFP-CWT method gives a clearer indication of the damage location than the conventionally used QPP-based (QPP-CWT method. Finally, an overall evaluation of the damage detection is outlined, as the identification results suggest that the newly proposed RFP-CWT method is accurate and reliable in terms of detection of damage locations on beam-like structures.

  10. Characteristic and quality control test in sector collimator gamma knife perfexion at Siloam hospital

    Science.gov (United States)

    Wesly Manik, Jhon; Hidayanto, Eko; Sutanto, Heri

    2017-01-01

    In this study conducted to evaluate the collimator 4 mm, 8 mm, 16 mm to determine the level of precision Gamma Knife Perfexion there three years and eight months has not carried out measurements after the first year and verify the alignment of sector 1-8. Measurement with three axes (x-axis, y-axis, z-axis) using the film Gafcromic EBT-3, which will be signaled to a central point in the film to be measured and given a dose of 5 Gy for 10 minutes and then scanned and analyzed using ImageJ softwere 1.50 and dose rate in film comparison with measurent dose rate using electrometer. Alignment of Patient-Positioning System (PPS) with Radiation Focal Point (RFP) determination of quality control testing each collimator 4 mm in the standard test with 0.4 mm passive voice AAPM 54. The results of the standard are still in conformity item 0.21 mm for 4 mm and corelasi dose rate film and measurent using electrometer collimator 4 mm = 0.965, 8 mm = 0.964, 16 mm = 0.959.

  11. Characteristic and quality control test in sector collimator gamma knife perfexion at Siloam hospital

    International Nuclear Information System (INIS)

    Manik, Jhon Wesly; Hidayanto, Eko; Sutanto, Heri

    2017-01-01

    In this study conducted to evaluate the collimator 4 mm, 8 mm, 16 mm to determine the level of precision Gamma Knife Perfexion there three years and eight months has not carried out measurements after the first year and verify the alignment of sector 1-8. Measurement with three axes (x-axis, y-axis, z-axis) using the film Gafcromic EBT-3, which will be signaled to a central point in the film to be measured and given a dose of 5 Gy for 10 minutes and then scanned and analyzed using ImageJ softwere 1.50 and dose rate in film comparison with measurent dose rate using electrometer. Alignment of Patient-Positioning System (PPS) with Radiation Focal Point (RFP) determination of quality control testing each collimator 4 mm in the standard test with < 0.1 and > 0.4 mm passive voice AAPM 54. The results of the standard are still in conformity item 0.21 mm for 4 mm and corelasi dose rate film and measurent using electrometer collimator 4 mm = 0.965, 8 mm = 0.964, 16 mm = 0.959. (paper)

  12. X-ray analysis of electron Bernstein wave heating in MST

    Energy Technology Data Exchange (ETDEWEB)

    Seltzman, A. H., E-mail: seltzman@wisc.edu; Anderson, J. K.; DuBois, A. M.; Almagri, A.; Forest, C. B. [Department of Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2016-11-15

    A pulse height analyzing x-ray tomography system has been developed to detect x-rays from electron Bernstein wave heated electrons in the Madison symmetric torus reversed field pinch (RFP). Cadmium zinc telluride detectors are arranged in a parallel beam array with two orthogonal multi-chord detectors that may be used for tomography. In addition a repositionable 16 channel fan beam camera with a 55° field of view is used to augment data collected with the Hard X-ray array. The chord integrated signals identify target emission from RF heated electrons striking a limiter located 12° toroidally away from the RF injection port. This provides information on heated electron spectrum, transport, and diffusion. RF induced x-ray emission from absorption on harmonic electron cyclotron resonances in low current (<250 kA) RFP discharges has been observed.

  13. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  14. Integrated Locomotor Function Tests for Countermeasure Evaluation

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    adaptive remodeling of the full-body gaze control systems following exposure to visual-vestibular conflict. Subjects walked on a treadmill before and after a 30- minute exposure to 0.5X minifying during which self-generated sinusoidal vertical head rotations were performed while seated. Following exposure to visual-vestibular conflict subjects showed a restriction in compensatory head movements, increased knee and ankle flexion after heel-strike and a decrease in the rate of body loading during the rapid weight transfer phase after the heel strike event. Taken together, results from both studies provide evidence that the full body contributes to gaze stabilization during locomotion, and that different functional elements are responsive to changes in visual task constraints and are subject to adaptive alterations following exposure to visual-vestibular conflict. This information provides the basis for the design of a new generation of integrative tests that incorporate the evaluation of multiple neural control systems relevant to astronaut operational performance.

  15. Integrating supervision, control and data acquisition—The ITER Neutral Beam Test Facility experience

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Simionato, P.; Zampiva, E.

    2016-11-15

    Highlights: • The paper describes the experience gained in the integration of different systems for the control and data acquisition system of the ITER Neutral Beam Test Facility. • It describes the way the different frameworks have been integrated. • It reports some lessons learnt during system integration. • It reports some authors’ considerations about the development the ITER CODAC. - Abstract: The ITER Neutral Beam (NBI) Test Facility, under construction in Padova, Italy consists in the ITER full scale ion source for the heating neutral beam injector, referred to as SPIDER, and the full size prototype injector, referred to as MITICA. The Control and Data Acquisition System (CODAS) for SPIDER has been developed and is going to be in operation in 2016. The system is composed of four main components: Supervision, Slow Control, Fast Control and Data Acquisition. These components interact with each other to carry out the system operation and, since they represent a common pattern in fusion experiments, software frameworks have been used for each (set of) component. In order to reuse as far as possible the architecture developed for SPIDER, it is important to clearly define the boundaries and the interfaces among the system components so that the implementation of any component can be replaced without affecting the overall architecture. This work reports the experience gained in the development of SPIDER components, highlighting the importance in the definition of generic interfaces among component, showing how the specific solutions have been adapted to such interfaces and suggesting possible approaches for the development of other ITER subsystems.

  16. Integrating supervision, control and data acquisition—The ITER Neutral Beam Test Facility experience

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Simionato, P.; Zampiva, E.

    2016-01-01

    Highlights: • The paper describes the experience gained in the integration of different systems for the control and data acquisition system of the ITER Neutral Beam Test Facility. • It describes the way the different frameworks have been integrated. • It reports some lessons learnt during system integration. • It reports some authors’ considerations about the development the ITER CODAC. - Abstract: The ITER Neutral Beam (NBI) Test Facility, under construction in Padova, Italy consists in the ITER full scale ion source for the heating neutral beam injector, referred to as SPIDER, and the full size prototype injector, referred to as MITICA. The Control and Data Acquisition System (CODAS) for SPIDER has been developed and is going to be in operation in 2016. The system is composed of four main components: Supervision, Slow Control, Fast Control and Data Acquisition. These components interact with each other to carry out the system operation and, since they represent a common pattern in fusion experiments, software frameworks have been used for each (set of) component. In order to reuse as far as possible the architecture developed for SPIDER, it is important to clearly define the boundaries and the interfaces among the system components so that the implementation of any component can be replaced without affecting the overall architecture. This work reports the experience gained in the development of SPIDER components, highlighting the importance in the definition of generic interfaces among component, showing how the specific solutions have been adapted to such interfaces and suggesting possible approaches for the development of other ITER subsystems.

  17. Implementation challenges for designing integrated in vitro testing strategies (ITS) aiming at reducing and replacing animal experimentation.

    Science.gov (United States)

    De Wever, Bart; Fuchs, Horst W; Gaca, Marianna; Krul, Cyrille; Mikulowski, Stan; Poth, Albrecht; Roggen, Erwin L; Vilà, Maya R

    2012-04-01

    At the IVTIP (in vitro testing industrial platform) meeting of November 26th 2009 entitled 'Toxicology in the 21st century ('21C')--working our way towards a visionary reality' all delegates endorsed the emerging concept of the '21C' vision as the way forward to enable a thorough, reliable and systematic approach to future toxicity testing without the use of animals. One of the emerging concepts focused on integrating a defined number of tests modelling in vivo-relevant and well-characterised toxicity pathways representing mechanistic endpoints. At this meeting the importance of Integrated Testing Strategies (ITS) as tools towards reduction and eventually replacement of the animals currently used for hazard identification and risk assessment was recognised. A follow-up IVTIP Spring 2010 meeting entitled 'Integrated In Vitro Testing Strategies (ITS)--Implementation Challenges' was organised to address pending questions about ITS. This report is not a review of the ITS literature, but a summary of the discussions triggered by presented examples on how to develop and implement ITS. Contrasts between pharmaceutical and chemical industry, as well as a list of general but practical aspects to be considered while developing an ITS emerged from the discussions. In addition, current recommendations on the validation of ITS were discussed. In conclusion, the outcome of this workshop improved the understanding of the participants of some important factors that may impact the design of an ITS in function of its purpose (e.g., screening, or early decision making versus regulatory), the context in which they need to be applied (e.g., ICH guidelines, REACH) and the status and quality of the available tools. A set of recommendations of best practices was established and the importance of the applicability of the individual tests as well as the testing strategy itself was highlighted. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Testing Requirements to Manage Data Exchange Specifications in Enterprise Integration - A Schema Design Quality Focus.

    Energy Technology Data Exchange (ETDEWEB)

    Kulvatunyou, Boonserm [ORNL; Ivezic, Nenad [ORNL; Buhwan, Jeong [POSTECH University, South Korea

    2004-07-01

    In this paper, we describe the requirements to test W3C XML Schema usage when defining message schemas for data exchange in any large and evolving enterprise integration project. We then decompose the XML Schema testing into four (4) aspects including the message schema conformance to the XML Schema specification grammar, the message schema conformance to the XML Schema specification semantics, the message schema conformance to design quality testing, and canonical semantics testing of the message schema. We describe these four testing aspects in some detail and point to other related efforts. We further focus to provide some technical details for the message schema design quality testing. As a future work, we describe the requirements for canonical semantics testing and potential solution approaches. Finally, we describe an implementation architecture for the message schema design quality testing.

  19. MODEL REQUEST FOR PROPOSALS TO PROVIDE ENERGY AND OTHER ATTRIBUTES FROM AN OFFSHORE WIND POWER PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeremy Firestone; Dawn Kurtz Crompton

    2011-10-22

    This document provides a model RFP for new generation. The 'base' RFP is for a single-source offshore wind RFP. Required modifications are noted should a state or utility seek multi-source bids (e.g., all renewables or all sources). The model is premised on proposals meeting threshold requirements (e.g., a MW range of generating capacity and a range in terms of years), RFP issuer preferences (e.g., likelihood of commercial operation by a date certain, price certainty, and reduction in congestion), and evaluation criteria, along with a series of plans (e.g., site, environmental effects, construction, community outreach, interconnection, etc.). The Model RFP places the most weight on project risk (45%), followed by project economics (35%), and environmental and social considerations (20%). However, if a multi-source RFP is put forward, the sponsor would need to either add per-MWh technology-specific, life-cycle climate (CO2), environmental and health impact costs to bid prices under the 'Project Economics' category or it should increase the weight given to the 'Environmental and Social Considerations' category.

  20. Ratiometric fluorescence polarization as a cytometric functional parameter: theory and practice

    International Nuclear Information System (INIS)

    Yishai, Yitzhak; Fixler, Dror; Cohen-Kashi, Meir; Zurgil, Naomi; Deutsch, Mordechai

    2003-01-01

    The use of ratiometric fluorescence polarization (RFP) as a functional parameter in monitoring cellular activation is suggested, based on the physical phenomenon of fluorescence polarization dependency on emission wavelengths in multiple (at least binary) solutions. The theoretical basis of this dependency is thoroughly discussed and examined via simulation. For simulation, aimed to imitate a fluorophore-stained cell, real values of the fluorescence spectrum and polarization of different single fluorophore solutions were used. The simulation as well as the experimentally obtained values of RFP indicated the high sensitivity of this measure. Finally, the RFP parameter was utilized as a cytometric measure in three exemplary cellular bioassays. In the first, the apoptotic effect of oxLDL in a human Jurkat FDA-stained T cell line was monitored by RFP. In the second, the interaction between cell surface membrane receptors of human T lymphocyte cells was monitored by RFP measurements as a complementary means to the fluorescence resonance energy transfer (FRET) technique. In the third bioassay, cellular thiol level of FDA- and CMFDA-labelled Jurkat T cells was monitored via RFP

  1. Corrosion and solubility in a TSP-buffered chemical environment following a loss of coolant accident: Part 4 – Integrated chemical effects testing

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Amir; LaBrier, Daniel [Department of Nuclear Engineering, University of New Mexico (United States); Blandford, Edward, E-mail: edb@unm.edu [Department of Nuclear Engineering, University of New Mexico (United States); Howe, Kerry [Department of Civil Engineering, University of New Mexico (United States)

    2016-04-15

    Highlights: • Integrated test explored the material release of a postulated large break LOCA. • Aluminum concentration was very low (<0.1 mg/L) throughout the test duration. • Zinc concentration was low (<1 mg/L) in TSP-buffered system. • Calcium release showed two distinguished release zones: prompt and meta-stable. • Copper and iron has no distinguishable concentration up to first 24 h of testing. - Abstract: This paper presents the results of an integrated chemical effects experiment executed under conditions representative of the containment pool following a postulated loss of coolant accident (LOCA) at the Vogtle nuclear power plant, operated by the Southern Nuclear Operating Company (SNOC). This test was conducted for closure of a series of bench scale experiments conducted to investigate the effect of the presence of trisodium phosphate (TSP) on the corrosion and release of aluminum (Howe et al., 2015) and zinc (Pease et al., 2015) from metallic surfaces, and calcium from NUKON fiberglass insulation (Olson et al., 2015) . The integrated test was performed in the Corrosion/Chemical Head Loss Experimental (CHLE) facility with representative amounts of zinc, aluminum, carbon steel, copper, NUKON fiberglass, and latent debris. The test was conducted using borated TSP-buffered solution under a post-LOCA prototypical temperature profile lasting for 30 days. The results presented in this article demonstrate trends for zinc, aluminum, and calcium release that are consistent with separate bench scale testing and previous integrated tests under TSP conditions. The release rate and maximum concentrations of the released materials were slightly different than the separate effect testing as a result of different experimental conditions (temperature, surface area-to-water volume ratio) and/or the presence of other metals and chemicals in the integrated test. Samples of metal coupons and fiberglass were selected for analysis using Scanning Electron Microscopy

  2. Corrosion and solubility in a TSP-buffered chemical environment following a loss of coolant accident: Part 4 – Integrated chemical effects testing

    International Nuclear Information System (INIS)

    Ali, Amir; LaBrier, Daniel; Blandford, Edward; Howe, Kerry

    2016-01-01

    Highlights: • Integrated test explored the material release of a postulated large break LOCA. • Aluminum concentration was very low (<0.1 mg/L) throughout the test duration. • Zinc concentration was low (<1 mg/L) in TSP-buffered system. • Calcium release showed two distinguished release zones: prompt and meta-stable. • Copper and iron has no distinguishable concentration up to first 24 h of testing. - Abstract: This paper presents the results of an integrated chemical effects experiment executed under conditions representative of the containment pool following a postulated loss of coolant accident (LOCA) at the Vogtle nuclear power plant, operated by the Southern Nuclear Operating Company (SNOC). This test was conducted for closure of a series of bench scale experiments conducted to investigate the effect of the presence of trisodium phosphate (TSP) on the corrosion and release of aluminum (Howe et al., 2015) and zinc (Pease et al., 2015) from metallic surfaces, and calcium from NUKON fiberglass insulation (Olson et al., 2015) . The integrated test was performed in the Corrosion/Chemical Head Loss Experimental (CHLE) facility with representative amounts of zinc, aluminum, carbon steel, copper, NUKON fiberglass, and latent debris. The test was conducted using borated TSP-buffered solution under a post-LOCA prototypical temperature profile lasting for 30 days. The results presented in this article demonstrate trends for zinc, aluminum, and calcium release that are consistent with separate bench scale testing and previous integrated tests under TSP conditions. The release rate and maximum concentrations of the released materials were slightly different than the separate effect testing as a result of different experimental conditions (temperature, surface area-to-water volume ratio) and/or the presence of other metals and chemicals in the integrated test. Samples of metal coupons and fiberglass were selected for analysis using Scanning Electron Microscopy

  3. Design and testing of integrated circuits for reactor protection channels

    International Nuclear Information System (INIS)

    Battle, R.E.; Vandermolen, R.I.; Jagadish, U.; Swail, B.K.; Naser, J.; Rana, I.

    1995-01-01

    Custom and semicustom application-specific integrated circuit design and testing methods are investigated for use in research and commercial nuclear reactor safety systems. The Electric Power Research Institute and Oak Ridge National Laboratory are working together through a cooperative research and development agreement to apply modern technology to a nuclear reactor protection system. Purpose of this project is to demonstrate to the nuclear industry an alternative approach for new or upgrade reactor protection and safety system signal processing and voting logic. Motivation for this project stems from (1) the difficulty of proving that software-based protection systems are adequately reliable, (2) the obsolescence of the original equipment, and (3) the improved performance of digital processing

  4. Improving power for rare-variant tests by integrating external controls.

    Science.gov (United States)

    Lee, Seunggeun; Kim, Sehee; Fuchsberger, Christian

    2017-11-01

    Due to the drop in sequencing cost, the number of sequenced genomes is increasing rapidly. To improve power of rare-variant tests, these sequenced samples could be used as external control samples in addition to control samples from the study itself. However, when using external controls, possible batch effects due to the use of different sequencing platforms or genotype calling pipelines can dramatically increase type I error rates. To address this, we propose novel summary statistics based single and gene- or region-based rare-variant tests that allow the integration of external controls while controlling for type I error. Our approach is based on the insight that batch effects on a given variant can be assessed by comparing odds ratio estimates using internal controls only vs. using combined control samples of internal and external controls. From simulation experiments and the analysis of data from age-related macular degeneration and type 2 diabetes studies, we demonstrate that our method can substantially improve power while controlling for type I error rate. © 2017 WILEY PERIODICALS, INC.

  5. Design and Integrity Evaluation of High-temperature Piping Systems in the STELLA-2 Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok-Kwon; Lee, Hyeong-Yeon; Eoh, JaeHyuk; Kim, Jong-Bum; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ju, Yong-Sun [KOASIS Inc., Daejeon (Korea, Republic of)

    2016-09-15

    In this study, elevated temperature design and integrity evaluation have been conducted using two different piping design codes for the high-temperature piping systems of sodium integral effect test loop for safety simulation and assessment(STELLA-2) being developed by KAERI(Korea Atomic Energy Research Institute). The design code of ASME B31.1 for power piping and French nuclear grade piping design guideline, RCC-MRx RD-3600 were applied, and conservatism of those codes was quantified based on the piping integrity evaluation results. The piping system of Model DHRS, Model IHTS and PSLS are to be installed in STELLA-2. The integrity evaluation results for the three piping systems according to the two design codes showed that integrity of the piping system was confirmed. As a code comparison result, ASME B31.1 was shown to be more conservative for sustained loads while RD-3600 was more conservative for thermal loads compared to B31.1.

  6. Integrated test plan ResonantSonic drilling system technology demonstration-1995, at the Hanford Site: Revision 1

    International Nuclear Information System (INIS)

    McLellan, G.W.

    1994-01-01

    This integrated test plan describes the demonstration test of the ResonantSonic drilling system. This demonstration is part of the Office of Technology Development's Volatile Organic Compound Arid Integrated Demonstration (VOC-Arid ID). Two main purposes of this demonstration are (1) to continue testing the ResonantSonic drilling system compatibility with the Hanford Site waste characterization programs, and (2) to transfer this method for use at the Hanford Site, other government sites, and the private sector. The ResonantSonic method is a dry drilling technique. Field testing of this method began in July 1993. During the next four months, nine holes were drilled, and continuous core samples were retrieved. Penetration rates were 2 to 3 times the baseline, and the operational downtime rate was less than 10%. Successfully demonstrated equipment refinements included a prototype 300 series ResonantSonic head, a new drill rod design for 18-centimeter diameter pipe, and an automated pipe handling system. Various configurations of sampling equipment and drill bits were tested, depending on geologic conditions. The principal objective of the VOC-Arid ID is to determine the viability of emerging technologies that can be used to characterize, remediate, and/or monitor arid or semiarid sites containing VOCs (e.g., carbon tetrachloride) with or without associated metal and radionuclide contamination

  7. Structural integrity test of prestressed concrete containment vessel for Tsuruga Unit No. 2 Nuclear Power Station

    International Nuclear Information System (INIS)

    Tamura, S.; Nagata, K.; Takeda, T.; Yamaguchi, T.; Nakayama, T.

    1987-01-01

    In introducing the PCCV to Japan, various verification tests were carried out to understand the structural performance of the PCCV and confirm the reliability of its design. In addition to those tests, a Structural Integrity Test (SIT) was conducted in Feb. 1986 as a final acceptance test. This report discusses the results of the SIT on the PCCV. The test was carried out simultaneously with an Integrated Leak Rate Test (ILRT) under the same pressure sequence. 1) Pressure-displacement relationships and pressure-strain relationships were more or less linear. 2) The measured displacement values at the maximum pressure (4.5 kgf/cm 2 G) corresponded well with calculated values. Correspondence with converted displacement obtained from strain and measured displacement was also good. 3) The residual displacement when 24 hours had elapsed after completion of depressurization was not more than 10% of the displacement at the maximum pressure. 4) The variation in tendon force at the maximum pressure is smaller than the calculated value in proportion to the elongation of the PCCV. 5) Although fine surface cracks due to shrinkage of concrete were seen, new structural cracks due to pressure were not observed. The leakage rate was evaluated at 0.016% of volume per day. It is much smaller than the design value of 0.1% of volume per day. (orig./HP)

  8. Development and verification test of integral reactor major components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability.

  9. Development and verification test of integral reactor major components

    International Nuclear Information System (INIS)

    Kim, J. I.; Kim, Y. W.; Kim, J. H. and others

    1999-03-01

    The conceptual designs for SG, MCP, CEDM to be installed in the integral reactor SMART were developed. Three-dimensional CAD models for the major components were developed to visualize the design concepts. Once-through helical steam generator was conceptually designed for SMART. Canned motor pump was adopted in the conceptual design of MCP. Linear pulse motor type and ballscrew type CEDM, which have fine control capabilities were studied for adoption in SMART. In parallel with the structural design, the electro-magnetic design was performed for the sizing motors and electro-magnet. Prototypes for the CEDM and MCP sub-assemblies were developed and tested to verify the performance. The impeller design procedure and the computer program to analyze the dynamic characteristics of MCP rotor shaft were developed. The design concepts of SG, MCP, CEDM were also invetigated for the fabricability

  10. 4H-SiC JFET Multilayer Integrated Circuit Technologies Tested Up to 1000 K

    Science.gov (United States)

    Spry, D. J.; Neudeck, P. G.; Chen, L.; Chang, C. W.; Lukco, D.; Beheim, G. M.

    2015-01-01

    Testing of semiconductor electronics at temperatures above their designed operating envelope is recognized as vital to qualification and lifetime prediction of circuits. This work describes the high temperature electrical testing of prototype 4H silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) technology implemented with multilayer interconnects; these ICs are intended for prolonged operation at temperatures up to 773K (500 C). A 50 mm diameter sapphire wafer was used in place of the standard NASA packaging for this experiment. Testing was carried out between 300K (27 C) and 1150K (877 C) with successful electrical operation of all devices observed up to 1000K (727 C).

  11. Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Peláez, Sarah S; Mahler, Hanns-Christian; Matter, Anja; Koulov, Atanas; Singh, Satish K; Germershaus, Oliver; Mathaes, Roman

    2018-04-04

    Prefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of six different PFSs from three different manufacturers (including one polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate CCIT. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment. Copyright © 2018. Published by Elsevier Inc.

  12. Integrated Stirling Convertor and Hall Thruster Test Conducted

    Science.gov (United States)

    Mason, Lee S.

    2002-01-01

    An important aspect of implementing Stirling Radioisotope Generators on future NASA missions is the integration of the generator and controller with potential spacecraft loads. Some recent studies have indicated that the combination of Stirling Radioisotope Generators and electric propulsion devices offer significant trip time and payload fraction benefits for deep space missions. A test was devised to begin to understand the interactions between Stirling generators and electric thrusters. An electrically heated RG- 350 (350-W output) Stirling convertor, designed and built by Stirling Technology Company of Kennewick, Washington, under a NASA Small Business Innovation Research agreement, was coupled to a 300-W SPT-50 Hall-effect thruster built for NASA by the Moscow Aviation Institute (RIAME). The RG-350 and the SPT-50 shown, were installed in adjacent vacuum chamber ports at NASA Glenn Research Center's Electric Propulsion Laboratory, Vacuum Facility 8. The Stirling electrical controller interfaced directly with the Hall thruster power-processing unit, both of which were located outside of the vacuum chamber. The power-processing unit accepted the 48 Vdc output from the Stirling controller and distributed the power to all the loads of the SPT-50, including the magnets, keeper, heater, and discharge. On February 28, 2001, the Glenn test team successfully operated the Hall-effect thruster with the Stirling convertor. This is the world's first known test of a dynamic power source with electric propulsion. The RG-350 successfully managed the transition from the purely resistive load bank within the Stirling controller to the highly capacitive power-processing unit load. At the time of the demonstration, the Stirling convertor was operating at a hot temperature of 530 C and a cold temperature of -6 C. The linear alternator was producing approximately 250 W at 109 Vac, while the power-processing unit was drawing 175 W at 48 Vdc. The majority of power was delivered to the

  13. Expression of membrane-associated proteins within single emulsion cell facsimiles.

    Science.gov (United States)

    Chanasakulniyom, Mayuree; Martino, Chiara; Paterson, David; Horsfall, Louise; Rosser, Susan; Cooper, Jonathan M

    2012-07-07

    MreB is a structural membrane-associated protein which is one of the key components of the bacterial cytoskeleton. Although it plays an important role in shape maintenance of rod-like bacteria, the understanding of its mechanism of action is still not fully understood. This study shows how segmented flow and microdroplet technology can be used as a new tool for biological in vitro investigation of this protein. In this paper, we demonstrate cell-free expression in a single emulsion system to express red fluorescence protein (RFP) and MreB linked RFP (MreB-RFP). We follow the aggregation and localisation of the fusion protein MreB-RFP in this artificial cell-like environment. The expression of MreB-RFP in single emulsion droplets leads to the formation of micrometer-scale protein patches distributed at the water/oil interface.

  14. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: METSAT A1 Signal Processor (P/N: 1331670-2, S/N: F04)

    Science.gov (United States)

    Lund, D.

    1998-01-01

    This report presents a description of the tests performed, and the test data, for the A1 METSAT Signal Processor Assembly PN: 1331679-2, S/N F04. The assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive Test and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

  15. Integrated testing strategies for toxicity employing new and existing technologies.

    Science.gov (United States)

    Combes, Robert D; Balls, Michael

    2011-07-01

    We have developed individual, integrated testing strategies (ITS) for predicting the toxicity of general chemicals, cosmetics, pharmaceuticals, inhaled chemicals, and nanoparticles. These ITS are based on published schemes developed previously for the risk assessment of chemicals to fulfil the requirements of REACH, which have been updated to take account of the latest developments in advanced in chemico modelling and in vitro technologies. In addition, we propose an ITS for neurotoxicity, based on the same principles, for incorporation in the other ITS. The technologies are deployed in a step-wise manner, as a basis for decision-tree approaches, incorporating weight-of-evidence stages. This means that testing can be stopped at the point where a risk assessment and/or classification can be performed, with labelling in accordance with the requirements of the regulatory authority concerned, rather than following a checklist approach to hazard identification. In addition, the strategies are intelligent, in that they are based on the fundamental premise that there is no hazard in the absence of exposure - which is why pharmacokinetic modelling plays a key role in each ITS. The new technologies include the use of complex, three-dimensional human cell tissue culture systems with in vivo-like structural, physiological and biochemical features, as well as dosing conditions. In this way, problems of inter-species extrapolation and in vitro/in vivo extrapolation are minimised. This is reflected in the ITS placing more emphasis on the use of volunteers at the whole organism testing stage, rather than on existing animal testing, which is the current situation. 2011 FRAME.

  16. Preparation, characterization, and in vitro cytotoxicity evaluation of a novel anti-tuberculosis reconstruction implant.

    Directory of Open Access Journals (Sweden)

    JunFeng Dong

    Full Text Available Reconstruction materials currently used in clinical for osteoarticular tuberculosis (TB are unsatisfactory due to a variety of reasons. Rifampicin (RFP is a well-known and highly effective first-line anti-tuberculosis (anti-TB drug. Poly-DL-lactide (PDLLA and nano-hydroxyapatite (nHA are two promising materials that have been used both for orthopedic reconstruction and as carriers for drug release. In this study we report the development of a novel anti-TB implant for osteoarticular TB reconstruction using a combination of RFP, PDLLA and nHA.RFP, PDLLA and nHA were used as starting materials to produce a novel anti-TB activity implant by the solvent evaporation method. After manufacture, the implant was characterized and its biodegradation and drug release profile were tested. The in vitro cytotoxicity of the implant was also evaluated in pre-osteoblast MC3T3-E1 cells using multiple methodologies.A RFP/PDLLA/nHA composite was successfully synthesized using the solvent evaporation method. The composite has a loose and porous structure with evenly distributed pores. The production process was steady and no chemical reaction occurred as proved by Fourier Transform Infrared Spectroscopy (FTIR and X-Ray Diffraction (XRD. Meanwhile, the composite blocks degraded and released drug for at least 12 weeks. Evaluation of in vitro cytotoxicity in MC3T3-E1 cells verified that the synthesized composite blocks did not affect cell growth and proliferation.It is feasible to manufacture a novel bioactive anti-TB RFP/PDLLA/nHA composite by the solvent evaporation method. The composite blocks showed appropriate properties such as degradation, drug release and biosafety to MC3T3-E1 cells. In conclusion, the novel composite blocks may have great potential for clinical applications in repairing bone defects caused by osteoarticular TB.

  17. Integrated System Health Management (ISHM) for Test Stand and J-2X Engine: Core Implementation

    Science.gov (United States)

    Figueroa, Jorge F.; Schmalzel, John L.; Aguilar, Robert; Shwabacher, Mark; Morris, Jon

    2008-01-01

    ISHM capability enables a system to detect anomalies, determine causes and effects, predict future anomalies, and provides an integrated awareness of the health of the system to users (operators, customers, management, etc.). NASA Stennis Space Center, NASA Ames Research Center, and Pratt & Whitney Rocketdyne have implemented a core ISHM capability that encompasses the A1 Test Stand and the J-2X Engine. The implementation incorporates all aspects of ISHM; from anomaly detection (e.g. leaks) to root-cause-analysis based on failure mode and effects analysis (FMEA), to a user interface for an integrated visualization of the health of the system (Test Stand and Engine). The implementation provides a low functional capability level (FCL) in that it is populated with few algorithms and approaches for anomaly detection, and root-cause trees from a limited FMEA effort. However, it is a demonstration of a credible ISHM capability, and it is inherently designed for continuous and systematic augmentation of the capability. The ISHM capability is grounded on an integrating software environment used to create an ISHM model of the system. The ISHM model follows an object-oriented approach: includes all elements of the system (from schematics) and provides for compartmentalized storage of information associated with each element. For instance, a sensor object contains a transducer electronic data sheet (TEDS) with information that might be used by algorithms and approaches for anomaly detection, diagnostics, etc. Similarly, a component, such as a tank, contains a Component Electronic Data Sheet (CEDS). Each element also includes a Health Electronic Data Sheet (HEDS) that contains health-related information such as anomalies and health state. Some practical aspects of the implementation include: (1) near real-time data flow from the test stand data acquisition system through the ISHM model, for near real-time detection of anomalies and diagnostics, (2) insertion of the J-2X

  18. Bootstrap Score Tests for Fractional Integration in Heteroskedastic ARFIMA Models, with an Application to Price Dynamics in Commodity Spot and Futures Markets

    DEFF Research Database (Denmark)

    Cavaliere, Giuseppe; Nielsen, Morten Ørregaard; Taylor, A.M. Robert

    Empirical evidence from time series methods which assume the usual I(0)/I(1) paradigm suggests that the efficient market hypothesis, stating that spot and futures prices of a commodity should cointegrate with a unit slope on futures prices, does not hold. However, these statistical methods...... fractionally integrated model we are able to find a body of evidence in support of the efficient market hypothesis for a number of commodities. Our new tests are wild bootstrap implementations of score-based tests for the order of integration of a fractionally integrated time series. These tests are designed...... principle do. A Monte Carlo simulation study demonstrates that very significant improvements infinite sample behaviour can be obtained by the bootstrap vis-à-vis the corresponding asymptotic tests in both heteroskedastic and homoskedastic environments....

  19. An Integrated Model of Academic Self-Concept Development: Academic Self-Concept, Grades, Test Scores, and Tracking over 6 Years

    Science.gov (United States)

    Marsh, Herbert W.; Pekrun, Reinhard; Murayama, Kou; Arens, A. Katrin; Parker, Philip D.; Guo, Jiesi; Dicke, Theresa

    2018-01-01

    Our newly proposed integrated academic self-concept model integrates 3 major theories of academic self-concept formation and developmental perspectives into a unified conceptual and methodological framework. Relations among math self-concept (MSC), school grades, test scores, and school-level contextual effects over 6 years, from the end of…

  20. On a Painleve test for the complete integrability of Bogomolny's monopole equation

    International Nuclear Information System (INIS)

    Roy Chowdhury, A.; Chanda, P.K.

    1984-09-01

    We have made an analysis of the monopole equation of Bogomolny from the stand point of Painleve test. The idea that any non-linear partial differential equation admitting a Lax representation should conform to the criterion of the Painleve analysis seems to hold well in case of Bogomolny equation. We have determined the position for resonances and have proved that at each of these the coefficients in the Forbenius type expansion of the gauge potentials do become arbitrary signalling the complete integrability of the system. (author)

  1. Integration and consistency testing of groundwater flow models with hydro-geochemistry in site investigations in Finland

    International Nuclear Information System (INIS)

    Pitkaenen, P.; Loefman, J.; Korkealaakso, J.; Koskinen, L.; Ruotsalainen, P.; Hautojaervi, A.; Aeikaes, T.

    1999-01-01

    In the assessment of the suitability and safety of a geological repository for radioactive waste the understanding of the fluid flow at a site is essential. In order to build confidence in the assessment of the hydrogeological performance of a site in various conditions, integration of hydrological and hydrogeochemical methods and studies provides the primary method for investigating the evolution that has taken place in the past, and for predicting future conditions at the potential disposal site. A systematic geochemical sampling campaign was started since the beginning of 1990's in the Finnish site investigation programme. This enabled the initiating of integration and evaluation of site scale hydrogeochemical and groundwater flow models. Hydrogeochemical information has been used to screen relevant external processes and variables for definition of the initial and boundary conditions in hydrological simulations. The results obtained from interpretation and modelling hydrogeochemical evolution have been employed in testing the hydrogeochemical consistency of conceptual flow models. Integration and testing of flow models with hydrogeochemical information are considered to improve significantly the hydrogeological understanding of a site and increases confidence in conceptual hydrogeological models. (author)

  2. A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests - 13342

    Energy Technology Data Exchange (ETDEWEB)

    Thien, Mike G. [Washington River Protection Solutions, LLC, P.O Box 850, Richland WA, 99352 (United States); Barnes, Steve M. [Waste Treatment Plant, 2435 Stevens Center Place, Richland WA 99354 (United States)

    2013-07-01

    The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)

  3. A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests - 13342

    International Nuclear Information System (INIS)

    Thien, Mike G.; Barnes, Steve M.

    2013-01-01

    The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)

  4. The Automated DC Parameter Testing of GaAs MESFETs Using the Singer Automatic Integrated Circuit Test System.

    Science.gov (United States)

    1980-09-01

    USING THE SINGER AUTOMATIC INTEGRATED CIRCUIT TEST SYSTEM, THOMAS L. HARPER AFIT/EE/GE/80- 7 Ist LT USAF -- -- - - __ AFIT/EE/GE/80-7 THE AUTOMATED DC...THOMAS L. HARPER ist Lt USAF Graduate Electrical Engineering September 1980 it’ Codes A _ _ _ J PREFACE This report is in support of the ongoing effort in...8217.-- I *t -1 ,p - tUel-, ir. ( /.s , j Yf) L) b ..... l P i:. +’ ,T i~: ",,’+l l L V i i ,’b : O Iil r, P V 47 C’+t ( ’ I ViH 47 V ’L 4 £, ,.;l 1 , h

  5. Integration and road tests of a self-sensing CNT concrete pavement system for traffic detection

    Science.gov (United States)

    Han, Baoguo; Zhang, Kun; Burnham, Tom; Kwon, Eil; Yu, Xun

    2013-01-01

    In this paper, a self-sensing carbon nanotube (CNT) concrete pavement system for traffic detection is proposed and tested in a roadway. Pre-cast and cast-in-place self-sensing CNT concrete sensors were simultaneously integrated into a controlled pavement test section at the Minnesota Road Research Facility (MnROAD), USA. Road tests of the system were conducted by using an MnROAD five-axle semi-trailer tractor truck and a van, respectively, both in the winter and summer. Test results show that the proposed self-sensing pavement system can accurately detect the passing of different vehicles under different vehicular speeds and test environments. These findings indicate that the developed self-sensing CNT concrete pavement system can achieve real-time vehicle flow detection with a high detection rate and a low false-alarm rate.

  6. Integration and road tests of a self-sensing CNT concrete pavement system for traffic detection

    International Nuclear Information System (INIS)

    Han, Baoguo; Zhang, Kun; Yu, Xun; Burnham, Tom; Kwon, Eil

    2013-01-01

    In this paper, a self-sensing carbon nanotube (CNT) concrete pavement system for traffic detection is proposed and tested in a roadway. Pre-cast and cast-in-place self-sensing CNT concrete sensors were simultaneously integrated into a controlled pavement test section at the Minnesota Road Research Facility (MnROAD), USA. Road tests of the system were conducted by using an MnROAD five-axle semi-trailer tractor truck and a van, respectively, both in the winter and summer. Test results show that the proposed self-sensing pavement system can accurately detect the passing of different vehicles under different vehicular speeds and test environments. These findings indicate that the developed self-sensing CNT concrete pavement system can achieve real-time vehicle flow detection with a high detection rate and a low false-alarm rate. (paper)

  7. Commissioning and integration testing of the DAQ system for the CMS GEM upgrade

    CERN Document Server

    Castaneda Hernandez, Alfredo Martin

    2017-01-01

    The CMS muon system will undergo a series of upgrades in the coming years to preserve and extend its muon detection capabilities during the High Luminosity LHC.The first of these will be the installation of triple-foil GEM detectors in the CMS forward region with the goal of maintaining trigger rates and preserving good muon reconstruction, even in the expected harsh environment.In 2017 the CMS GEM project is looking to achieve a major milestone in the project with the installation of 5 super-chambers in CMS; this exercise will allow for the study of services installation and commissioning, and integration with the rest of the subsystems for the first time. An overview of the DAQ system will be given with emphasis on the usage during chamber quality control testing, commissioning in CMS, and integration with the central CMS system.

  8. On-line reactor building integrity testing at Gentilly-2 (summary of results 1987-1994)

    International Nuclear Information System (INIS)

    Collins, N.; Lafreniere, P.

    1994-01-01

    In 1987, Hydro-0uebec embarked on an ambitious development program to provide the Gentilly-2 Nuclear Power Station with an effective and practical Reactor Building Containment integrity Test (CIT). In October 1992, the inaugural low pressure (3 kPa(g) nominal) CIT at 100% F.P was performed. The test was conclusive and the CIT was declared In-Service for containment integrity verification on-line. Five subsequent CITs performed in 1993 and 1994 have demonstrated the expected leak rate results and good reliability. The outstanding feature of the CITs is the demonstrated accurary of better than 5% of the measured leak rate. The CIT was developed with the primary goal of demonstrating 'overall' containment availability. Specifically it was designed to detect a 25 mm. diameter leak or hole in the Reactor Building. However, the remarkable CIT accuracy allows reliable detection of a 2 mm. hole. The Gentilly-2 CIT is an innovative approach based on the Temperature Compensation Method (TCM) which uses a reference volume composed of an extensive tubular network of several different diameters. This eliminates the need to track numerous temperature points. A second independent tubular network includes numerous humidity sampling points, thereby enabling the mearurernent of minute pressure variations inside the Reactor Building, independant of the spatial and temporal humidity behaviour. This Gentilly-2 TOM System has been demonstrated to work at both high and low test pressures. The GentiIly-2 design allows the CIT to be performed at a nominal 3 kPa(g) test pressure during a 12-hour period (28 hours total with alignment time) with the reactor at full power. The traditional Reactor Building Pressure Test (RBPT) is typically performed at high pressure (124 kPa(g) in a 5-day critical path window (7 days total with alignment time) during an annual shutdown

  9. Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John L.; Morris, Jonathan A.; Turowski, Mark P.; Franzl, Richard

    2010-01-01

    This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

  10. The integrated in situ testing program for the Waste Isolation Pilot Plant (WIPP)

    International Nuclear Information System (INIS)

    Matalucci, R.V.

    1987-03-01

    The US Department of Energy (DOE) is developing the Waste Isolation Pilot Plant (WIPP) Project in southeastern New Mexico as a research and development (R and D) facility for examining the response of bedded (layered) salt to the emplacement of radioactive wastes generated from defense programs. The WIPP Experimental Program consists of a technology development program, including laboratory testing and theoretical analysis activities, and an in situ testing program that is being done 659 m underground at the project site. This experimental program addresses three major technical areas that concern (1) thermal/structural interactions, (2) plugging and sealing, and (3) waste package performance. To ensure that the technical issues involved in these areas are investigated with appropriate emphasis and timing, an in situ testing plan was developed to integrate the many activities and tasks associated with the technical issues of waste disposal. 5 refs., 4 figs

  11. Integrity assessment of TAPS reactor pressure vessel at extended EOL using surveillance test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah, Priti Kotak

    2008-05-01

    Integrity assessment of pressure vessels of nuclear reactors (RPV) primarily concentrates on the prevention of brittle failure and conditions are defined under which brittle failure can be excluded. Accordingly, two approaches based on Transition Temperature Concept and Fracture Mechanics Concept were adopted using the impact test results of three credible surveillance data sets obtained from the surveillance specimens of Tarapur Atomic Power Station. RT NDT data towards end of life (EOL) were estimated from the impact test results in accordance with the procedures of USNRC Regulatory Guide 1.99, Rev. 2 and were used as primary input for assessment of the vessel integrity. SA302B (nickel modified) steel cladded with stainless steel is used as the pressure vessel material for the two 210 MWe boiling water reactors of the Tarapur Atomic Power Station (TAPS). The reactors were commissioned during the year 1969. The chemical compositions of SA302B (modified) steel used in fabricating the vessel and the specified tensile property and the Charpy impact property requirements of the steel broadly meet ASME specified requirements. Therefore, the pressure temperature limit curves prescribed by General Electric (G.E.) were compared with those as obtained using procedures of ASME Section XII, Appendix G. The tensile and the Charpy impact properties at 60 EFPY of vessel operation as derived from the surveillance specimens even fulfilled the specified requirements for the virgin material of ASME. Integrity assessment carried out using the two approaches indicated the safety of the vessel for continued operation up to 60 EFPY. (author)

  12. Integrated test plan for the field demonstration of the supported liquid membrane unit

    International Nuclear Information System (INIS)

    Dunks, K.L.; Hodgson, K.M.

    1995-06-01

    This Integrated Test Plan describes the operation and testing of a hybrid reverse osmosis (RO)/coupled transport (CT) groundwater remediation test unit, also referred to as the Environmental Restoration Technology Demonstrations at the Hanford Site. The SLM will be used to remove uranium, technetium-99, and nitrate from a selected groundwater source at the Hanford Site. The overall purpose of this test is to determine the efficiency of the RO/CT membranes operating in a hybrid unit, the ease of operating and maintaining the SLM, and the amount of secondary waste generated as a result of processing. The goal of the SLM is to develop a RO/CT process that will be applicable for removing contaminants from almost any contaminated water. This includes the effluents generated as part of the day-to-day operation of most any US Department of Energy (DOE) site. The removal of contaminants from the groundwaters before they reach the Columbia River or offsite extraction wells will reduce the risk that the population will be exposed to these compounds and will reduce the cost of subsequent groundwater cleanup

  13. A construct with fluorescent indicators for conditional expression of miRNA

    Directory of Open Access Journals (Sweden)

    Xia Xugang

    2008-10-01

    Full Text Available Abstract Background Transgenic RNAi holds promise as a simple, low-cost, and fast method for reverse genetics in mammals. It may be particularly useful for producing animal models for hypomorphic gene function. Inducible RNAi that permits spatially and temporally controllable gene silencing in vivo will enhance the power of transgenic RNAi approach. Furthermore, because microRNA (miRNA targeting specific genes can be expressed simultaneously with protein coding genes, incorporation of fluorescent marker proteins can simplify the screening and analysis of transgenic RNAi animals. Results We sought to optimally express a miRNA simultaneously with a fluorescent marker. We compared two construct designs. One expressed a red fluorescent protein (RFP and a miRNA placed in its 3' untranslated region (UTR. The other expressed the same RFP and miRNA, but the precursor miRNA (pre-miRNA coding sequence was placed in an intron that was inserted into the 3'-UTR. We found that the two constructs expressed comparable levels of miRNA. However, the intron-containing construct expressed a significantly higher level of RFP than the intron-less construct. Further experiments indicate that the 3'-UTR intron enhances RFP expression by its intrinsic gene-expression-enhancing activity and by eliminating the inhibitory effect of the pre-miRNA on the expression of RFP. Based on these findings, we incorporated the intron-embedded pre-miRNA design into a conditional expression construct that employed the Cre-loxP system. This construct initially expressed EGFP gene, which was flanked by loxP sites. After exposure to Cre recombinase, the transgene stopped EGFP expression and began expression of RFP and a miRNA, which silenced the expression of specific cellular genes. Conclusion We have designed and tested a conditional miRNA-expression construct and showed that this construct expresses both the marker genes strongly and can silence the target gene efficiently upon Cre

  14. Integrated testing strategies (ITS) for bioaccumulation: hierarchical scheme of chemistrydriven modules and definition of applicability domains

    DEFF Research Database (Denmark)

    Nendza, M.; Scheringer, M.; Strempel, S.

    2011-01-01

    The efficient assessment of the bioaccumulation potential of chemicals under REACH with integrated test strategies (ITS) requires multiple tools. Existing data have to be searched and information from chemical structures and physico-chemical properties need to be evaluated prior to considering to...

  15. NEK containment integrated leak rate test at full pressure

    International Nuclear Information System (INIS)

    Skaler, F.; Planinc, V.; Gregoric, D.; Cicvaric, D.

    1999-01-01

    NPP Krsko is a Pressure Water Reactor (PWR) Plant which has four barriers to prevent release of radioactive fission products. These four barriers are following: Fuel itself, Fuel Clad, Reactor Coolant System and Containment Building. Containment is the last barrier which can prevent release of fission product when other barriers have been already broken. To find out the real condition of containment vessel and to prove its ability of withstanding increased parameters during accident we have to perform Containment Integrated Leak Rate Test at least three times in every ten years of operation. CILRT 1999 in NPP Krsko was completely performed following regulation of 10CFR50 App. J Option A and ANSI/ANS 56.8-1987. The main goal of CILRT is to prove that the leakage of containment pathways and wall structures are within limits prescribed in Technical Specifications by pressurization of containment building above peak accident pressure Pa and measuring the mass changes of air using Ideal Gas Law.(author)

  16. Design and testing of integrated circuits for reactor protection channels

    International Nuclear Information System (INIS)

    Battle, R.E.; Vandermolen, R.I.; Jagadish, U.; Swail, B.K.; Naser, J.

    1995-01-01

    Custom and semicustom application-specific integrated circuit design and testing methods are investigated for use in research and commercial nuclear reactor safety systems. The Electric Power Research Institute and Oak Ridge National Laboratory are working together through a cooperative research and development agreement to apply modern technology to a nuclear reactor protection system. The purpose of this project is to demonstrate to the nuclear industry an alternative approach for new or upgrade reactor protection and safety system signal processing and voting logic. Motivation for this project stems from (1) the difficulty of proving that software-based protection systems are adequately reliable, (2) the obsolescence of the original equipment, and (3) the improved performance of digital processing. A demonstration model for protection system of PWR reactor has been designed and built

  17. AAV-mediated delivery of the transcription factor XBP1s into the striatum reduces mutant Huntingtin aggregation in a mouse model of Huntington’s disease

    International Nuclear Information System (INIS)

    Zuleta, Amparo; Vidal, Rene L.; Armentano, Donna; Parsons, Geoffrey; Hetz, Claudio

    2012-01-01

    Highlights: ► The contribution of ER stress to HD has not been directly addressed. ► Expression of XBP1s using AAVs decreases Huntingtin aggregation in vivo. ► We describe a new in vivo model of HD based on the expression of a large fragment of mHtt-RFP. -- Abstract: Huntington’s disease (HD) is caused by mutations that expand a polyglutamine region in the amino-terminal domain of Huntingtin (Htt), leading to the accumulation of intracellular inclusions and progressive neurodegeneration. Recent reports indicate the engagement of endoplasmic reticulum (ER) stress responses in human HD post mortem samples and animal models of the disease. Adaptation to ER stress is mediated by the activation of the unfolded protein response (UPR), an integrated signal transduction pathway that attenuates protein folding stress by controlling the expression of distinct transcription factors including X-Box binding protein 1 (XBP1). Here we targeted the expression of XBP1 on a novel viral-based model of HD. We delivered an active form of XBP1 locally into the striatum of adult mice using adeno-associated vectors (AAVs) and co-expressed this factor with a large fragment of mutant Htt as a fusion protein with RFP (Htt588 Q95 -mRFP) to directly visualize the accumulation of Htt inclusions in the brain. Using this approach, we observed a significant reduction in the accumulation of Htt588 Q95 -mRFP intracellular inclusion when XBP1 was co-expressed in the striatum. These results contrast with recent findings indicating a protective effect of XBP1 deficiency in neurodegeneration using knockout mice, and suggest a potential use of gene therapy strategies to manipulate the UPR in the context of HD.

  18. The TITAN Reversed-Field Pinch fusion reactor study

    International Nuclear Information System (INIS)

    1988-03-01

    The TITAN Reversed-Field Pinch (RFP) fusion reactor study is a multi-institutional research effort to determine the technical feasibility and key developmental issues of an RFP fusion reactor, especially at high power density, and to determine the potential economics, operations, safety, and environmental features of high-mass-power-density fusion systems. The TITAN conceptual designs are DT burning, 1000 MWe power reactors based on the RFP confinement concept. The designs are compact, have a high neutron wall loading of 18 MW/m 2 and a mass power density of 700 kWe/tonne. The inherent characteristics of the RFP confinement concept make fusion reactors with such a high mass power density possible. Two different detailed designs have emerged: the TITAN-I lithium-vanadium design, incorporating the integrated-blanket-coil concept; and the TITAN-II aqueous loop-in-pool design with ferritic steel structure. This report contains a collection of 16 papers on the results of the TITAN study which were presented at the International Symposium on Fusion Nuclear Technology. This collection describes the TITAN research effort, and specifically the TITAN-I and TITAN-II designs, summarizing the major results, the key technical issues, and the central conclusions and recommendations. Overall, the basic conclusions are that high-mass power-density fusion reactors appear to be technically feasible even with neutron wall loadings up to 20 MW/m 2 ; that single-piece maintenance of the FPC is possible and advantageous; that the economics of the reactor is enhanced by its compactness; and the safety and environmental features need not to be sacrificed in high-power-density designs. The fact that two design approaches have emerged, and others may also be possible, in some sense indicates the robustness of the general findings

  19. Upgrading and extended testing of the MSC integrated water and waste management hardware

    Science.gov (United States)

    Bambenek, R. A.; Nuccio, P. P.; Hurley, T. L.; Jasionowski, W. J.

    1972-01-01

    The results are presented of upgrading and testing an integrated water and waste management system, which uses the compression distillation, reverse osmosis, adsorption filtration and ion-exchange processes to recover potable water from urine, flush water and used wash water. Also included is the development of techniques for extending the useful biological life of biological filters, activated carbon filters and ion-exchange resins to at least 30 days, and presterilizing ion-exchange resins so that sterile water can be recovered from waste water. A wide variety of reverse osmosos materials, surfactants and germicides were experimentally evaluated to determine the best combination for a wash water subsystem. Full-scale module tests with real wash water demonstrated that surface fouling is a major problem.

  20. System Description of the Electrical Power Supply System for the ATLAS Integral Test Loop

    International Nuclear Information System (INIS)

    Moon, S. K.; Park, J. K.; Kim, Y. S.; Song, C. H.; Baek, W. P.

    2007-02-01

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), is constructed by Thermal-Hydraulics Safety Research Team in Korea Atomic Energy Research Institute (KAERI). The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400. This report describes the design and technical specifications of the electrical power supply system which supplies the electrical powers to core heater rods, other heaters, various pumps and other systems. The electrical power supply system had acquired the final approval on the operation from the Korea Electrical Safety Corporation. During performance tests for the operation and control, the electrical power supply system showed completely acceptable operation and control performance

  1. Construct-driven development of a video-based situational judgment test for integrity : A study in a multi-ethnic police setting

    NARCIS (Netherlands)

    L.A.L. de Meijer (Lonneke); M.Ph. Born (Marise); J. van Zielst (Jaap); H.T. van der Molen (Henk)

    2010-01-01

    textabstractIn a field study conducted in a multi-ethnic selection setting at the Dutch police, we examined the construct validity of a video-based situational judgment test (SJT) aimed to measure the construct of integrity. Integrity is of central importance to productive work performance of police

  2. Advanced fighter technology integration (AFTI)/F-16 Automated Maneuvering Attack System final flight test results

    Science.gov (United States)

    Dowden, Donald J.; Bessette, Denis E.

    1987-01-01

    The AFTI F-16 Automated Maneuvering Attack System has undergone developmental and demonstration flight testing over a total of 347.3 flying hours in 237 sorties. The emphasis of this phase of the flight test program was on the development of automated guidance and control systems for air-to-air and air-to-ground weapons delivery, using a digital flight control system, dual avionics multiplex buses, an advanced FLIR sensor with laser ranger, integrated flight/fire-control software, advanced cockpit display and controls, and modified core Multinational Stage Improvement Program avionics.

  3. Integrated experimental test program on waterhammer pressure pulses and associated structural responses within a feedwater sparger

    Energy Technology Data Exchange (ETDEWEB)

    Nurkkala, P.; Hoikkanen, J. [Imatran Voima Oy, Vantaa (Finland)

    1997-12-31

    This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The feedwater sparger was subjected to the full range of operating parameters which were to result in waterhammer pressure pulse trains of various magnitudes and duration. Two different designs of revised feedwater sparger were investigated (i.e. `grounded` and `with goose neck`). The following objects were to be met within this program: (1) establish the thermohydraulic parameters that facilitate the occurrence of water hammer pressure pulses, (2) provide a database for further analysis of the pressure pulse phenomena, (3) establish location and severity of these water hammer pressure pulses, (4) establish the structural response due to these pressure pulses, (5) provide input data for structural integrity analysis. (orig.). 3 refs.

  4. Integrated experimental test program on waterhammer pressure pulses and associated structural responses within a feedwater sparger

    International Nuclear Information System (INIS)

    Nurkkala, P.; Hoikkanen, J.

    1997-01-01

    This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The feedwater sparger was subjected to the full range of operating parameters which were to result in waterhammer pressure pulse trains of various magnitudes and duration. Two different designs of revised feedwater sparger were investigated (i.e. 'grounded' and 'with goose neck'). The following objects were to be met within this program: (1) establish the thermohydraulic parameters that facilitate the occurrence of water hammer pressure pulses, (2) provide a database for further analysis of the pressure pulse phenomena, (3) establish location and severity of these water hammer pressure pulses, (4) establish the structural response due to these pressure pulses, (5) provide input data for structural integrity analysis. (orig.)

  5. Integrated experimental test program on waterhammer pressure pulses and associated structural responses within a feedwater sparger

    Energy Technology Data Exchange (ETDEWEB)

    Nurkkala, P; Hoikkanen, J [Imatran Voima Oy, Vantaa (Finland)

    1998-12-31

    This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The feedwater sparger was subjected to the full range of operating parameters which were to result in waterhammer pressure pulse trains of various magnitudes and duration. Two different designs of revised feedwater sparger were investigated (i.e. `grounded` and `with goose neck`). The following objects were to be met within this program: (1) establish the thermohydraulic parameters that facilitate the occurrence of water hammer pressure pulses, (2) provide a database for further analysis of the pressure pulse phenomena, (3) establish location and severity of these water hammer pressure pulses, (4) establish the structural response due to these pressure pulses, (5) provide input data for structural integrity analysis. (orig.). 3 refs.

  6. Engineering and physics of high-power-density, compact, reversed-field-pinch fusion reactors

    International Nuclear Information System (INIS)

    Najmabadi, F.; Conn, R.W.; Krakowski, R.A.; Schultz, K.R.; Steiner, D.

    1989-01-01

    The technical feasibility and key developmental issues of compact, high-power-density Reversed-Field-Pinch (RFP) reactors are the primary results of the TITAN RFP reactor study. Two design approaches emerged, TITAN-I and TITAN-II, both of which are steady-state, DT-burning, circa 1000 MWe power reactors. The TITAN designs are physically compact and have a high neutron wall loading of 18 MW m 2 . Detailed analyses indicate that: a) each design is technically feasible; b) attractive features of compact RFP reactors can be realized without sacrificing the safety and environmental potential of fusion; and c) major features of this particular embodiment of the RFP reactor are retained in a design window of neutron wall loading ranging from 10 to 20 MW/m 2 . A major product of the TITAN study is the identification and quantification of major engineering and physics requirements for this class of RFP reactors. These findings are the focus of this paper. (author). 26 refs.; 4 figs.; 1 tab

  7. Temperature evolution in a magnetohydrodynamics simulation of a reversed-field pinch

    International Nuclear Information System (INIS)

    Onofri, M.; Malara, F.; Veltri, P.

    2010-01-01

    The temperature evolution in a magnetohydrodynamics (MHD) simulation of a reversed-field pinch (RFP) is investigated including thermal conductivity. For numerical reasons, an isotropic thermal conductivity is used, even though in a RFP plasma the parallel conductivity is much larger than the perpendicular one so that magnetic field lines tend to become isothermal. The system shows alternating multiple helicity states and quasi-single helicity states. Single-helical-axis states are formed when the amplitude of the dominant mode is above a determined threshold, as observed in experiments. The relation between heat transport and magnetic field topology that is observed in RFP experiments cannot be found in the simulation, since thermal conductivity is independent of the magnetic field. This difficulty should be taken into account in the numerical investigation of the RFP dynamics. In this paper, the first description of the temperature evolution in a compressible MHD simulation of a RFP is given.

  8. Role of magnetic reconnection phenomena in the reversed-field pinch

    International Nuclear Information System (INIS)

    Baker, D.A.

    1983-01-01

    The reversed-field pinch (RFP), an axisymmetric toroidal magnetic confinement experiment, has physics rich in the area commonly called field line reconnection or merging. This paper reviews the topics where reconnection plays a vital role: (a) RFP formation and the phenomenon of self-reversal, (b) RFP sustainment in which the RFP configuration has been shown to be capable of maintaining itself for times much longer than earlier predictions from classical resistive MHD theory, (c) steady state current drive in which dynamo action and associated reconnection processes give rise to the possibility of sustaining the configuration indefinitely by means of low frequency ac modulation of the toroidal and poloidal magnetic fields, (d) the effects of reconnection on the formation and evolution of the magnetic surfaces which are intimately related to the plasma containment properties. It appears that all phases of the RFP operation are intimately related to the reconnection and field regeneration processes similar to those encountered in space and astrophysics

  9. Training Systems Product Group (TSPG) Training Systems Acquisition (TSA)

    Science.gov (United States)

    2006-05-23

    Ceiling Status • Ceiling Reserve Programs to be Awarded – FY 06 • HC-130P Ogden RFP: May 06 • ATARS Ogden RFP: Apr 06 • F-16 MSAMT FMS WP RFP: TOPS...set-asides • Set up a method for potential teams members to identify one another • Continue to make opportunities and award available to industry • Must streamline D.O. bids and turn tasks quickly

  10. Test and diagnosis of analogue, mixed-signal and RF integrated circuits the system on chip approach

    CERN Document Server

    Sun, Yichuang

    2008-01-01

    This book provides a comprehensive discussion of automatic testing, diagnosis and tuning of analogue, mixed-signal and RF integrated circuits, and systems in a single source. The book contains eleven chapters written by leading researchers worldwide. As well as fundamental concepts and techniques, the book reports systematically the state of the arts and future research directions of these areas. A complete range of circuit components are covered and test issues are also addressed from the SoC perspective.

  11. Rapid transcriptional pulsing dynamics of high expressing retroviral transgenes in embryonic stem cells.

    Directory of Open Access Journals (Sweden)

    Mandy Y M Lo

    Full Text Available Single cell imaging studies suggest that transcription is not continuous and occurs as discrete pulses of gene activity. To study mechanisms by which retroviral transgenes can transcribe to high levels, we used the MS2 system to visualize transcriptional dynamics of high expressing proviral integration sites in embryonic stem (ES cells. We established two ES cell lines each bearing a single copy, self-inactivating retroviral vector with a strong ubiquitous human EF1α gene promoter directing expression of mRFP fused to an MS2-stem-loop array. Transfection of MS2-EGFP generated EGFP focal dots bound to the mRFP-MS2 stem loop mRNA. These transcription foci colocalized with the transgene integration site detected by immunoFISH. Live tracking of single cells for 20 minutes detected EGFP focal dots that displayed frequent and rapid fluctuations in transcription over periods as short as 25 seconds. Similarly rapid fluctuations were detected from focal doublet signals that colocalized with replicated proviral integration sites by immunoFISH, consistent with transcriptional pulses from sister chromatids. We concluded that retroviral transgenes experience rapid transcriptional pulses in clonal ES cell lines that exhibit high level expression. These events are directed by a constitutive housekeeping gene promoter and may provide precedence for rapid transcriptional pulsing at endogenous genes in mammalian stem cells.

  12. W-026 integrated engineering cold run operational test report for balance of plant (BOP)

    International Nuclear Information System (INIS)

    Kersten, J.K.

    1998-01-01

    This Cold Run test is designed to demonstrate the functionality of systems necessary to move waste drums throughout the plant using approved procedures, and the compatibility of these systems to function as an integrated process. This test excludes all internal functions of the gloveboxes. In the interest of efficiency and support of the facility schedule, the initial revision of the test (rev 0) was limited to the following: Receipt and storage of eight overpacked drums, four LLW and four TRU; Receipt, routing, and staging of eleven empty drums to the process area where they will be used later in this test; Receipt, processing, and shipping of two verification drums (Route 9); Receipt, processing, and shipping of two verification drums (Route 1). The above listed operations were tested using the rev 0 test document, through Section 5.4.25. The document was later revised to include movement of all staged drums to and from the LLW and TRU process and RWM gloveboxes. This testing was performed using Sections 5.5 though 5.11 of the rev 1 test document. The primary focus of this test is to prove the functionality of automatic operations for all mechanical and control processes listed. When necessary, the test demonstrates manual mode operations as well. Though the gloveboxes are listed, only waste and empty drum movement to, from, and between the gloveboxes was tested

  13. Determinants of facility readiness for integration of family planning with HIV testing and counseling services: evidence from the Tanzania service provision assessment survey, 2014-2015.

    Science.gov (United States)

    Bintabara, Deogratius; Nakamura, Keiko; Seino, Kaoruko

    2017-12-22

    Global policy reports, national frameworks, and programmatic tools and guidance emphasize the integration of family planning and HIV testing and counseling services to ensure universal access to reproductive health care and HIV prevention. However, the status of integration between these two services in Tanzanian health facilities is unclear. This study examined determinants of facility readiness for integration of family planning with HIV testing and counseling services in Tanzania. Data from the 2014-2015 Tanzania Service Provision Assessment Survey were analyzed. Facilities were considered ready for integration of family planning with HIV testing and counseling services if they scored ≥ 50% on both family planning and HIV testing and counseling service readiness indices as identified by the World Health Organization. All analyses were adjusted for clustering effects, and estimates were weighted to correct for non-responses and disproportionate sampling. Descriptive, bivariate, and multivariate logistic regression analyses were performed. A total of 1188 health facilities were included in the study. Of all of the health facilities, 915 (77%) reported offering both family planning and HIV testing and counseling services, while only 536 (45%) were considered ready to integrate these two services. Significant determinants of facility readiness for integrating these two services were being government owned [AOR = 3.2; 95%CI, 1.9-5.6], having routine management meetings [AOR = 1.9; 95%CI, 1.1-3.3], availability of guidelines [AOR = 3.8; 95%CI, 2.4-5.8], in-service training of staff [AOR = 2.6; 95%CI, 1.3-5.2], and availability of laboratories for HIV testing [AOR = 17.1; 95%CI, 8.2-35.6]. The proportion of facility readiness for the integration of family planning with HIV testing and counseling in Tanzania is unsatisfactory. The Ministry of Health should distribute and ensure constant availability of guidelines, availability of rapid diagnostic

  14. Reversed field pinch diagnostics

    International Nuclear Information System (INIS)

    Weber, P.G.

    1986-01-01

    The Reversed Field Pinch (RFP) is a toroidal, axisymmetric magnetic confinement configuration characterized by a magnetic field configuration in which the toroidal magnetic field is of similar strength to the poloidal field, and is reversed at the edge compared to the center. The RFP routinely operates at high beta, and is a strong candidate for a compact fusion device. Relevant attributes of the configuration will be presented, together with an overview of present and planned experiments and their diagnostics. RFP diagnostics are in many ways similar to those of other magnetic confinement devices (such as tokamaks); these lectures will point out pertinent differences, and will present some diagnostics which provide special insights into unique attributes of the RFP

  15. Confinement dynamics and boundary condition studies in the Reversed Field Pinch

    International Nuclear Information System (INIS)

    Schoenberg, K.F.; Ingraham, J.C.; Moses, R.W. Jr.

    1988-01-01

    The study of confinement dynamics, including investigation of the boundary conditions required for plasma sustainment, are central to the development of the Reversed Field Pinch (RFP) concept. Recently, several insights into confinement have emerged from a detailed investigation RFP electron and ion dynamics. These insights derive from the recognition that both magnetohydrodynamic (MHD) and electron kinetic effects play an important and coupled role in RFP stability, sustainment, and confinement. In this paper, we summarize the results of confinement studies on the ZT-40M experiment, and boundary condition studies on the Wisconsin non-circular RFP experiment. A brief description of the newly commissioned Madison Symmetric Torus (MST) is also presented. 28 refs., 3 figs

  16. Fuel integrity project: analysis of light water reactor fuel rods test results

    International Nuclear Information System (INIS)

    Dallongeville, M.; Werle, J.; McCreesh, G.

    2004-01-01

    BNFL Nuclear Sciences and Technology Services and COGEMA LOGISTICS started in the year 2000 a joint project known as FIP (Fuel Integrity Project) with the aim of developing realistic methods by which the response of LWR fuel under impact accident conditions could be evaluated. To this end BNFL organised tests on both unirradiated and irradiated fuel pin samples and COGEMA LOGISTICS took responsibility for evaluating the test results. Interpretation of test results included simple mechanical analysis as well as simulation by Finite Element Analysis. The first tests that were available for analysis were an irradiated 3 point bending commissioning trial and a lateral irradiated hull compression test, both simulating the loading during a 9 m lateral regulatory drop. The bending test span corresponded roughly to a fuel pin intergrid distance. The outcome of the test was a failure starting at about 35 mm lateral deflection and a few percent of total deformation. Calculations were carried out using the ANSYS code employing a shell and brick model. The hull lateral compaction test corresponds to a conservative compression by neighbouring pins at the upper end of the fuel pin. In this pin region there are no pellets inside. The cladding broke initially into two and later into four parts, all of which were rather similar. Initial calculations were carried out with LS-DYNA3D models. The models used were optimised in meshing, boundary conditions and material properties. The calculation results compared rather well with the test data, in particular for the detailed ANSYS approach of the 3 point bending test, and allowed good estimations of stresses and deformations under mechanical loading as well as the derivation of material rupture criteria. All this contributed to the development of realistic numerical analysis methods for the evaluation of LWR fuel rod behaviour under both normal and accident transport conditions. This paper describes the results of the 3 point bending

  17. Fuel integrity project: analysis of light water reactor fuel rods test results

    Energy Technology Data Exchange (ETDEWEB)

    Dallongeville, M.; Werle, J. [COGEMA Logistics (AREVA Group) (France); McCreesh, G. [BNFL Nuclear Sciences and Technology Services (United Kingdom)

    2004-07-01

    BNFL Nuclear Sciences and Technology Services and COGEMA LOGISTICS started in the year 2000 a joint project known as FIP (Fuel Integrity Project) with the aim of developing realistic methods by which the response of LWR fuel under impact accident conditions could be evaluated. To this end BNFL organised tests on both unirradiated and irradiated fuel pin samples and COGEMA LOGISTICS took responsibility for evaluating the test results. Interpretation of test results included simple mechanical analysis as well as simulation by Finite Element Analysis. The first tests that were available for analysis were an irradiated 3 point bending commissioning trial and a lateral irradiated hull compression test, both simulating the loading during a 9 m lateral regulatory drop. The bending test span corresponded roughly to a fuel pin intergrid distance. The outcome of the test was a failure starting at about 35 mm lateral deflection and a few percent of total deformation. Calculations were carried out using the ANSYS code employing a shell and brick model. The hull lateral compaction test corresponds to a conservative compression by neighbouring pins at the upper end of the fuel pin. In this pin region there are no pellets inside. The cladding broke initially into two and later into four parts, all of which were rather similar. Initial calculations were carried out with LS-DYNA3D models. The models used were optimised in meshing, boundary conditions and material properties. The calculation results compared rather well with the test data, in particular for the detailed ANSYS approach of the 3 point bending test, and allowed good estimations of stresses and deformations under mechanical loading as well as the derivation of material rupture criteria. All this contributed to the development of realistic numerical analysis methods for the evaluation of LWR fuel rod behaviour under both normal and accident transport conditions. This paper describes the results of the 3 point bending

  18. Report on FY17 testing in support of integrated EPP-SMT design methods development

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanli . [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jetter, Robert I. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sham, T. -L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. The purpose of this methodology is to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, thermomechanical tests continued in FY17. This report presents the recent test results for Type 1 SMT specimens on Alloy 617 with long hold times, pressurization SMT on Alloy 617, and two-bar thermal ratcheting test results on SS316H at the temperature range of 405 °C to 705 °C. Preliminary EPP strain range analysis on the two-bar tests are critically evaluated and compared with the experimental results.

  19. Theoretical study on the laser-driven ion-beam trace probe in toroidal devices with large poloidal magnetic field

    Science.gov (United States)

    Yang, X.; Xiao, C.; Chen, Y.; Xu, T.; Yu, Y.; Xu, M.; Wang, L.; Wang, X.; Lin, C.

    2018-03-01

    Recently, a new diagnostic method, Laser-driven Ion-beam Trace Probe (LITP), has been proposed to reconstruct 2D profiles of the poloidal magnetic field (Bp) and radial electric field (Er) in the tokamak devices. A linear assumption and test particle model were used in those reconstructions. In some toroidal devices such as the spherical tokamak and the Reversal Field Pinch (RFP), Bp is not small enough to meet the linear assumption. In those cases, the error of reconstruction increases quickly when Bp is larger than 10% of the toroidal magnetic field (Bt), and the previous test particle model may cause large error in the tomography process. Here a nonlinear reconstruction method is proposed for those cases. Preliminary numerical results show that LITP could be applied not only in tokamak devices, but also in other toroidal devices, such as the spherical tokamak, RFP, etc.

  20. Uncertainty and sensitivity analyses for age-dependent unavailability model integrating test and maintenance

    International Nuclear Information System (INIS)

    Kančev, Duško; Čepin, Marko

    2012-01-01

    Highlights: ► Application of analytical unavailability model integrating T and M, ageing, and test strategy. ► Ageing data uncertainty propagation on system level assessed via Monte Carlo simulation. ► Uncertainty impact is growing with the extension of the surveillance test interval. ► Calculated system unavailability dependence on two different sensitivity study ageing databases. ► System unavailability sensitivity insights regarding specific groups of BEs as test intervals extend. - Abstract: The interest in operational lifetime extension of the existing nuclear power plants is growing. Consequently, plants life management programs, considering safety components ageing, are being developed and employed. Ageing represents a gradual degradation of the physical properties and functional performance of different components consequently implying their reduced availability. Analyses, which are being made in the direction of nuclear power plants lifetime extension are based upon components ageing management programs. On the other side, the large uncertainties of the ageing parameters as well as the uncertainties associated with most of the reliability data collections are widely acknowledged. This paper addresses the uncertainty and sensitivity analyses conducted utilizing a previously developed age-dependent unavailability model, integrating effects of test and maintenance activities, for a selected stand-by safety system in a nuclear power plant. The most important problem is the lack of data concerning the effects of ageing as well as the relatively high uncertainty associated to these data, which would correspond to more detailed modelling of ageing. A standard Monte Carlo simulation was coded for the purpose of this paper and utilized in the process of assessment of the component ageing parameters uncertainty propagation on system level. The obtained results from the uncertainty analysis indicate the extent to which the uncertainty of the selected

  1. Development of Integral Effect Test Facility P and ID and Technical Specification for SMART Fluid System

    International Nuclear Information System (INIS)

    Lee, Sang Il; Jung, Y. H.; Yang, H. J.; Song, S. Y.; Han, O. J.; Lee, B. J.; Kim, Y. A.; Lim, J. H.; Park, K. W.; Kim, N. G.

    2010-01-01

    SMART integral test loop is the thermal hydraulic test facility with a high pressure and temperature for simulating the major systems of the prototype reactor, SMART-330. The objective of this project is to conduct the basic design for constructing SMART ITL. The major results of this project include a series of design documents, technical specifications and P and ID. The results can be used as the fundamental materials for making the detailed design which is essential for manufacturing and installing SMART ITL

  2. Integrating mediation and moderation to advance theory development and testing.

    Science.gov (United States)

    Karazsia, Bryan T; Berlin, Kristoffer S; Armstrong, Bridget; Janicke, David M; Darling, Katherine E

    2014-03-01

    The concepts and associated analyses of mediation and moderation are important to the field of psychology. Although pediatric psychologists frequently incorporate mediation and moderation in their theories and empirical research, on few occasions have we integrated mediation and moderation. In this article, conceptual reasons for integrating mediation and moderation are offered. We illustrate a model that integrates mediation and moderation. In our illustration, the strength of an indirect or a mediating effect varied as a function of a moderating variable. Clinical implications of the integration of mediation and moderation are discussed, as is the potential of integrated models to advance research programs in pediatric psychology.

  3. Estimation of integrity of cast-iron cask against impact due to free drop test, (1)

    International Nuclear Information System (INIS)

    Itoh, Chihiro

    1988-01-01

    Ductile cast iron is examined to use for shipping and storage cask from a economic point of view. However, ductile cast iron is considered to be a brittle material in general. Therefore, it is very important to estimate the integrity of cast iron cask against brittle failure due to impact load at 9 m drop test and 1 m derop test on to pin. So, the F.E.M. analysis which takes nonlinearity of materials into account and the estimation against brittle failure by the method which is proposed in this report were carried out. From the analysis, it is made clear that critical flaw depth (the minimum depth to initiate the brittle failure) is 21.1 mm and 13.1 mm in the case of 9 m drop test and 1 m drop test on to pin respectively. These flaw depth can be detected by ultrasonic test. Then, the cask is assured against brittle failure due to impact load at 9 m drop test and 1 m drop test on to pin. (author)

  4. Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M., E-mail: mpalomo@iqn.upv.es [Departamento de Ingenieria Quimica y Nuclear. Universidad Politecnica de Valencia (Spain); Urrea, M., E-mail: Matias.urrea@iberdrola.es [C.N.Cofrentes - Iberdrola Generacion S.A., Cofrentes, Valencia (Spain); Curiel, M., E-mail: m.curiel@lainsa.com [LAINSA Grupo Dominguis, Valencia (Spain); Arnaldos, A., E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Tecnologicos SL, Grupo Dominguis, Valencia (Spain)

    2011-07-01

    This paper we present is related to SIPPING machine control system new design to perform integrity of nuclear fuel test. This test is a non destructive technique used for evaluating the radiated nuclear fuel coating structural integrity. It is based on the radioactive emission detection of fission elements in the reactor cooling system, using the fuel inspection equipment (SIPPING). SIPPING equipment consists of one simultaneous test bell-shaped vessel of eight fuel elements, and another one for individual element test, a control workstation and some accessories (cables, thermocouples, hoses). SIPPING inspection is carried out by means of fuel element vessel. Through air injection, water flows around the element and heat evacuation is reduced, so fuel elements temperature increases. Those elements with faults shall expelled fission components dissolved in water and/or as a gas component. The project aim is the SIPPING system control design and software based on LabVIEW, for control, monitoring and documentation of the SIPPING Test. This project shall give a major functionality to the system and, at the same time, shall facilitate the user a friendlier and interactive environment allowing: to substitute the present work platform with a real-time electronic system based on cRIO and a control software ad-hoc designed for SIPPING system; to equip new system of a major redundancy for data storage, minimising loss probability of the same. (author)

  5. Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Palomo, M. J. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Urrea, M. [Iberdrola Generacion S. A., Central Nuclear Cofrentes, Carretera Almansa Requena s/n, 04662 Cofrentes, Valencia (Spain); Vaquer, J., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    This paper related to Sipping machine control system new design to perform integrity of nuclear fuel test. This test is a non destructive technique used for evaluating the radiated nuclear fuel coating structural integrity. It is based on the radioactive emission detection of fission elements in the reactor cooling system, using the fuel inspection equipment Sipping. The equipment consists of one simultaneous test bell-shaped vessel of eight fuel elements, and another one for individual element test, a control workstation and some accessories (cables, thermocouples, hoses). Sipping inspection is carried out by means of fuel element vessel. Through air injection, water flows around the element and heat evacuation is reduced, so fuel elements temperature increases. Those elements with faults shall expelled fission components dissolved in water and/or as a gas component. The project aim is the Sipping system control design and software based on LabVIEWTM, for control, monitoring and documentation of the Sipping test. This project shall give a major functionality to the system and, at the same time, shall facilitate the user a friendlier and interactive environment allowing: 1) To substitute the present work platform with a real-time electronic system based on cRIO and a control software ad-hoc designed for Sipping system. 2) To equip new system of a major redundancy for data storage, minimising loss probability of the same. (Author)

  6. Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant

    International Nuclear Information System (INIS)

    Curiel, M.; Palomo, M. J.; Urrea, M.; Vaquer, J.

    2010-10-01

    This paper related to Sipping machine control system new design to perform integrity of nuclear fuel test. This test is a non destructive technique used for evaluating the radiated nuclear fuel coating structural integrity. It is based on the radioactive emission detection of fission elements in the reactor cooling system, using the fuel inspection equipment Sipping. The equipment consists of one simultaneous test bell-shaped vessel of eight fuel elements, and another one for individual element test, a control workstation and some accessories (cables, thermocouples, hoses). Sipping inspection is carried out by means of fuel element vessel. Through air injection, water flows around the element and heat evacuation is reduced, so fuel elements temperature increases. Those elements with faults shall expelled fission components dissolved in water and/or as a gas component. The project aim is the Sipping system control design and software based on LabVIEWTM, for control, monitoring and documentation of the Sipping test. This project shall give a major functionality to the system and, at the same time, shall facilitate the user a friendlier and interactive environment allowing: 1) To substitute the present work platform with a real-time electronic system based on cRIO and a control software ad-hoc designed for Sipping system. 2) To equip new system of a major redundancy for data storage, minimising loss probability of the same. (Author)

  7. Targeting BRCAness in Gastric Cancer

    Science.gov (United States)

    2017-10-01

    affected in subsets of these tumors. For example, mutations in BRCA1/2 were found in about 15% of gastric cancer, loss of BRCA1 protein expression...platform   Figure 4: Nuclear-RFP tagged SNU1 cell lines after 6 days in culture . (A) Phase contrast. (B) RFP. (C) Markup image of RFP confluence...Title: Cell Cultures and Xenografts from Esophagogastric, Pancreatic, Colorectal and Neuroendocrine Tumors, IACUC protocol number 10-02-003, Protocol

  8. A Color-coded Imageable Syngeneic Mouse Model of Stromal-cell Recruitment by Metastatic Lymphoma.

    Science.gov (United States)

    Matsumoto, Takuro; Suetsugu, Atsushi; Shibata, Yuhei; Nakamura, Nobuhiko; Aoki, Hitomi; Kunisada, Takahiro; Tsurumi, Hisashi; Shimizu, Masahito; Hoffman, Robert M

    2015-09-01

    A syngeneic color-coded imageable lymphoma model has been developed to visualize recruitment of host stromal cells by malignant lymphoma during metastasis. The EL4 cell line was previously derived from a lymphoma induced in a C57/BL6 mouse by 9,10-dimethyl-1,2-benzanthracene. EL4 lymphoma cells expressing red fluorescent protein (EL4-RFP) were initially established. EL4-RFP cells were subsequently injected into the tail vein of C57/BL6-GFP transgenic mice. EL4-RFP metastasis was observed in the lymph nodes of the upper mediastinum and in the liver 28 days after cell injection. Large EL4-RFP liver metastases in C57/BL6-GFP mice contained GFP-expressing stromal cells derived from the host. In addition, EL4-RFP lymphoma metastasis was formed in peri-gastric lymph nodes, which were also enriched in host GFP-expressing cells. Furthermore, EL4-RFP lymphoma cells were also observed in the peripheral blood and bone marrow of C57/BL6-GFP transgenic mice, where they were associated with GFP-expressing host cells. Lymph node, liver and bone marrow metastases were found approximately 4 weeks after transplantation and all RFP-expressing metastases were highly enriched in GFP-expressing host stromal cells. This model of malignant lymphoma can be used to study early tumor development, metastasis, and the role of the stroma, as well as for discovery and evaluation of novel therapeutics for this treatment-resistant disease. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  9. The Self-Calibration Test of flowmeter installed in STELLA(Sodium Integral Effect Test Loop for Safety Simulation and Assessment) facility

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Minhwan; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The objective of this study is to describe the procedure of the self-calibration test for the flowmeters and to analyze the result of the test. In this work, the test procedure of the self-calibration of two flowmeters (FT-101, FT-102) installed in STELLA facility was described and the test result was analyzed. In regard to the long-term SFR development plan, a large-scale sodium thermal-hydraulic test project is being progressed by KAERI. This project is called STELLA (Sodium Integral Effect Test Loop for Safety Simulation and Assessment), and it is proceeding by adopting the QA (Quality Assurance) program. Due to the specificity of an experiment using sodium(Na) categorized as Class 3(pyrophoric material and water-prohibiting substance) by the Safety Control of Dangerous Substances Act, it is necessary to apply QA in consideration of the sodium experiment environment in certain parts. The one of them is about calibration of measuring instrument such as a flowmeter, thermocouple and pressure gauge. It is described in the QAP (Quality Assurance Procedures) of KAERI that calibration work should be conducted in accordance with self-calibration procedures in a special case where conventional calibration is not practicable. The calibration of two flowmeters (FT-101, FT-102) installed in STELLA facility is the typical example. As a result of test, it was confirmed that the flowmeters meet the pass criterion. Therefore, it was concluded that the flowmeters maintain instrument capacity a year ago.

  10. RF Testing Of Microwave Integrated Circuits

    Science.gov (United States)

    Romanofsky, R. R.; Ponchak, G. E.; Shalkhauser, K. A.; Bhasin, K. B.

    1988-01-01

    Fixtures and techniques are undergoing development. Four test fixtures and two advanced techniques developed in continuing efforts to improve RF characterization of MMIC's. Finline/waveguide test fixture developed to test submodules of 30-GHz monolithic receiver. Universal commercially-manufactured coaxial test fixture modified to enable characterization of various microwave solid-state devices in frequency range of 26.5 to 40 GHz. Probe/waveguide fixture is compact, simple, and designed for non destructive testing of large number of MMIC's. Nondestructive-testing fixture includes cosine-tapered ridge, to match impedance wavequide to microstrip. Advanced technique is microwave-wafer probing. Second advanced technique is electro-optical sampling.

  11. Using the Integrative Model of Behavioral Prediction to Understand College Students' STI Testing Beliefs, Intentions, and Behaviors.

    Science.gov (United States)

    Wombacher, Kevin; Dai, Minhao; Matig, Jacob J; Harrington, Nancy Grant

    2018-03-22

    To identify salient behavioral determinants related to STI testing among college students by testing a model based on the integrative model of behavioral (IMBP) prediction. 265 undergraduate students from a large university in the Southeastern US. Formative and survey research to test an IMBP-based model that explores the relationships between determinants and STI testing intention and behavior. Results of path analyses supported a model in which attitudinal beliefs predicted intention and intention predicted behavior. Normative beliefs and behavioral control beliefs were not significant in the model; however, select individual normative and control beliefs were significantly correlated with intention and behavior. Attitudinal beliefs are the strongest predictor of STI testing intention and behavior. Future efforts to increase STI testing rates should identify and target salient attitudinal beliefs.

  12. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  13. Compact Reversed-Field Pinch Reactors (CRFPR): preliminary engineering considerations

    International Nuclear Information System (INIS)

    Hagenson, R.L.; Krakowski, R.A.; Bathke, C.G.; Miller, R.L.; Embrechts, M.J.; Schnurr, N.M.; Battat, M.E.; LaBauve, R.J.; Davidson, J.W.

    1984-08-01

    The unique confinement physics of the Reversed-Field Pinch (RFP) projects to a compact, high-power-density fusion reactor that promises a significant reduction in the cost of electricity. The compact reactor also promises a factor-of-two reduction in the fraction of total cost devoted to the reactor plant equipment [i.e., fusion power core (FPC) plus support systems]. In addition to operational and developmental benefits, these physically smaller systems can operate economically over a range of total power output. After giving an extended background and rationale for the compact fusion approaches, key FPC subsystems for the Compact RFP Reactor (CRFPR) are developed, designed, and integrated for a minimum-cost, 1000-MWe(net) system. Both the problems and promise of the compact, high-power-density fusion reactor are quantitatively evaluated on the basis of this conceptual design. The material presented in this report both forms a framework for a broader, more expanded conceptual design as well as suggests directions and emphases for related research and development

  14. Physical understanding of the instability spectrum and the feedback control of resistive wall modes in reversed field pinch

    International Nuclear Information System (INIS)

    Wang, Z.R.; Guo, S.C.

    2011-01-01

    The cylindrical MHD model integrated with a feedback system is applied to the study of resistive wall mode (RWM) in reversed field pinch (RFP) plasmas. The model takes into account the compressibility, longitudinal flow, viscosity and resistive wall with a finite thickness. The study, via both analytical and numerical analyses, provides a physical understanding on the following subjects: firstly, on the nature of the instability spectrum of the RWM observed in RFP plasmas; specifically, the growth rates of the two groups of the RWMs (internally non-resonant and externally non-resonant) have opposite dependence on the variation of the field reversal. Secondly, on the response of the unstable plasmas to the feedback control in RFPs, the mode behaviour in plasmas under the feedback is clarified and discussed in detail. Finally, the linear solutions of time evolution of RWM instability in various feedback scenarios are given. The effects of the wall proximity, the sensor location and the system response time are discussed, respectively.

  15. HIV Testing and Cross Border Migrant Vulnerability: Social Integration and Legal/Economic Status Among Cross Border Migrant Workers in Thailand.

    Science.gov (United States)

    Ford, Kathleen; Holumyong, Charamporn

    2016-04-01

    The objective of this paper was to identify factors related to the use of HIV testing among cross border migrants in Thailand. Two measures of vulnerability (social integration and legal/economic status) as well as HIV knowledge, risk behaviour, and demographic factors were tested for association with HIV testing. Data were drawn from a survey of 2600 sexually active migrants age 15-59 in multiple provinces of Thailand. The measures of social integration (AOR = 1.14(95 % CI 1.09, 1.20) female; AOR = 1.12 (95 %CI 1.05, 1.19) male) and legal-income status (AOR = 1.12 (95 % CI 1.07, 1.18) female; AOR = 1.31 (95 %CI 1.20, 1.42) male) were positively related to the odds of reporting an HIV test for both male and female migrants. Exposure to AIDS programming including attending an AIDS meeting and possessing AIDS knowledge was also related to an increase in HIV testing. In addition, reproductive health factors including sexual risk behavior and childbirth increased the rate of HIV testing.

  16. An integrated automatic system for the eddy-current testing of the steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Hee Gon; Choi, Seong Su [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    This research project was focused on automation of steam generator tubes inspection for nuclear power plants. ECT (Eddy Current Testing) inspection process in nuclear power plants is classified into 3 subprocesses such as signal acquisition process, signal evaluation process, and inspection planning and data management process. Having been automated individually, these processes were effectively integrated into an automatic inspection system, which was implemented in HP workstation with expert system developed (author). 25 refs., 80 figs.

  17. An integrated automatic system for the eddy-current testing of the steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Hee Gon; Choi, Seong Su [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1996-12-31

    This research project was focused on automation of steam generator tubes inspection for nuclear power plants. ECT (Eddy Current Testing) inspection process in nuclear power plants is classified into 3 subprocesses such as signal acquisition process, signal evaluation process, and inspection planning and data management process. Having been automated individually, these processes were effectively integrated into an automatic inspection system, which was implemented in HP workstation with expert system developed (author). 25 refs., 80 figs.

  18. Structure Integrity Testing of Mineral Feed by Means of Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Jaroslav Začal

    2016-01-01

    Full Text Available This work deals with specific method of non-destructive testing – Acoustic emission (AE. Theoretical part of article is focused on underlying principle of this method and its applicability. The experimental part is focused on research of pressure resistance in mineral feed using the AE. Mineral feed is condensed cube of rock salt (sodium chloride with supplementary minerals, which is fed to livestock and game to supply the mineral elements necessary for their health and condition. Using the AE sensor is possible to provide monitoring of internal changes in the material. AE gives the overview of internal changes in material structure. With use of specific software we can interpret the acoustic signal and identify the current state of material integrity in real time.

  19. Factors Affecting Aerosol Radiative Forcing from Both Production-based and Consumption-based View

    Science.gov (United States)

    Wang, J.; Lin, J.; Ni, R.

    2017-12-01

    Aerosol radiative forcing (RF) is determined by emissions and various chemical-transport-radiative processes in the atmosphere, a multi-factor problem whose individual contributors have not been well quantified. This problem becomes more complicated when taking into account the role of international trade, which means reallocated aerosol RF due to separation of regions producing goods and emissions and regions consuming those goods. Here we analyze major factors affecting RF of secondary inorganic aerosols (SIOAs, including sulfate, nitrate and ammonium), primary organic aerosol (POA) and black carbon (BC), extending the work of Lin et al. (2016, Nature Geoscience). We contrast five factors determining production-based (RFp, due to a region's production of goods) and consumption-based (RFc, due to a region's consumption) forcing by 11 major regions, including population size, per capita output, emission intensity (emission per output), chemical efficiency (mass per unit emission) and radiative efficiency (RF per unit mass). Comparing across the 11 regions, East Asia produces the strongest RFp and RFc of SIOA and BC and the second largest RFp and RFc of POA primarily due to its high emission intensity. Although Middle East and North Africa has low emissions, its RFp is strengthened by its largest chemical efficiency for POA and BC and second largest chemical efficiency for SIOA. However, RFp of South-East Asia and Pacific is greatly weakened by its lowest chemical efficiency. Economic trade means that net importers (Western Europe, North America and Pacific OECD) have higher RFc than RFp by 50-100%. And such forcing difference is mainly due to the high emission intensity of the exporters supplying these regions. For North America, SIOA's RFc is 50% stronger than RFp, for that emission intensity of SIOA is 5.2 times in East Asia and 2.5 times in Latin America and Caribbean compared with that in North America, and the chemical efficiency in the top four exporters are

  20. Turbulent transport in reversed field pinches

    International Nuclear Information System (INIS)

    Christiansen, J.P.; Roberts, K.V.

    1976-01-01

    MHD stability of the Reversed Field Pinch (RFP) relies on reversal of the toroidal field component in the outer plasma region. Interest in this configuration comes from its potential economic advantages as a thermonuclear reactor, since compared to a Tokamak the RFP supports a higher value of β, the ratio between plasma and total magnetic pressure. Results of computations on the time-evolution of the RFP using a 1D MHD model are reported. (orig./GG) [de

  1. Road Testing Graduate Attributes and Course Learning Outcomes of an Environmental Science Degree via a Work-Integrated Learning Placement

    Science.gov (United States)

    Whelan, Michael

    2017-01-01

    Graduate attributes and course learning outcomes are an integral part of higher education in Australia. Testing the performance of graduates in the workplace with regard to graduate attributes and course learning outcomes is a not a common occurrence. This study has road tested the graduate attributes and course learning outcomes of a bachelor…

  2. Design and test results of a low-noise readout integrated circuit for high-energy particle detectors

    International Nuclear Information System (INIS)

    Zhang Mingming; Chen Zhongjian; Zhang Yacong; Lu Wengao; Ji Lijiu

    2010-01-01

    A low-noise readout integrated circuit for high-energy particle detector is presented. The noise of charge sensitive amplifier was suppressed by using single-side amplifier and resistors as source degeneration. Continuous-time semi-Gaussian filter is chosen to avoid switch noise. The peaking time of pulse shaper and the gain can be programmed to satisfy multi-application. The readout integrated circuit has been designed and fabricated using a 0.35 μm double-poly triple-metal CMOS technology. Test results show the functions of the readout integrated circuit are correct. The equivalent noise charge with no detector connected is 500-700 e in the typical mode, the gain is tunable within 13-130 mV/fC and the peaking time varies from 0.7 to 1.6 μs, in which the average gain is about 20.5 mV/fC, and the linearity reaches 99.2%. (authors)

  3. Integrative literature review of the reported uses of serological tests in leprosy management.

    Science.gov (United States)

    Fabri, Angélica da Conceição Oliveira Coelho; Carvalho, Ana Paula Mendes; Vieira, Nayara Figueiredo; Bueno, Isabela de Caux; Rodrigues, Rayssa Nogueira; Monteiro, Thayenne Barrozo Mota; Correa-Oliveira, Rodrigo; Duthie, Malcolm S; Lana, Francisco Carlos Félix

    2016-04-01

    An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

  4. Space-Borne and Ground-Based InSAR Data Integration: The Åknes Test Site

    Directory of Open Access Journals (Sweden)

    Federica Bardi

    2016-03-01

    Full Text Available This work concerns a proposal of the integration of InSAR (Interferometric Synthetic Aperture Radar data acquired by ground-based (GB and satellite platforms. The selected test site is the Åknes rockslide, which affects the western Norwegian coast. The availability of GB-InSAR and satellite InSAR data and the accessibility of a wide literature make the landslide suitable for testing the proposed procedure. The first step consists of the organization of a geodatabase, performed in the GIS environment, containing all of the available data. The second step concerns the analysis of satellite and GB-InSAR data, separately. Two datasets, acquired by RADARSAT-2 (related to a period between October 2008 and August 2013 and by a combination of TerraSAR-X and TanDEM-X (acquired between July 2010 and October 2012, both of them in ascending orbit, processed applying SBAS (Small BAseline Subset method, are available. GB-InSAR data related to five different campaigns of measurements, referred to the summer seasons of 2006, 2008, 2009, 2010 and 2012, are available, as well. The third step relies on data integration, performed firstly from a qualitative point of view and later from a semi-quantitative point of view. The results of the proposed procedure have been validated by comparing them to GPS (Global Positioning System data. The proposed procedure allowed us to better define landslide sectors in terms of different ranges of displacements. From a qualitative point of view, stable and unstable areas have been distinguished. In the sector concerning movement, two different sectors have been defined thanks to the results of the semi-quantitative integration step: the first sector, concerning displacement values higher than 10 mm, and the 2nd sector, where the displacements did not exceed a 10-mm value of displacement in the analyzed period.

  5. Development of a crosshole sonic logging system for the integrity test of cast-in-situ piles

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tai-Sup; Sung, Nak-Hoon; Hwang, Hak-Soo [Korea Institute of Geoscience and Mineral Resources, Taejeon(Korea)

    2001-09-01

    To evaluate the integrity of cast-in-situ concrete piles, a notebook PC-based crosshole sonic logging system which can be handled by one operator was developed using PCMCIA-type analog to digital converter card. User-interactive software for operation of the system were also developed using Labview. The system was tested with the field model pile to confirm the performance of the developed system. The test result shows that the system is very stable and efficient for detecting defects of the pile. (author). 3 refs., 9 figs.

  6. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 108 2

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1 SIN 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  7. Validación de un método de cromatografía líquida para la determinación de rifampicina en plasma humano

    Directory of Open Access Journals (Sweden)

    Luis Moreno-Exebio

    Full Text Available Objetivos: Validar un método de cromatografía líquida de alta resolución (HPLC para la determinación de rifampicina (RFP en plasma humano. Materiales y métodos. Se desarrolló un método HPLC para la determinación de RFP en plasma. La separación fue realizada por cromatografía de fase reversa con una columna C18 y una fase móvil compuesta por una mezcla de acetonitrilo y solución amortiguadora de fosfato de potasio monobásico 0,05 M (38:62 v/v a 335 nm. En el cual se empleó como estándar interno rifampicina quinona (RFP-QN. Resultados. Los tiempos de retención de RFP y RFP-QN fueron 7,81 y 12,26 minutos, respectivamente. El ensayo fue lineal de 0,5 a 250 ug/mL Los parámetros evaluados de precisión, exactitud, selectividad, linealidad, recuperación cumplieron con lo establecido en las guías internacionales de validación de métodos bioanalíticos. Conclusiones. El método HPLC desarrollado es simple, específico, sensible, selectivo y lineal para un amplio rango de concentraciones de RFP en plasma

  8. Integrated solidity test measurement of the airtight compartment system at the Paks nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Osztheimer, M.; Taubner, R.; Techy, Zs. (Villamosenergiaipari Kutato Intezet, Budapest (Hungary))

    1983-01-01

    A brief report on the purpose of the integrated solidity test measurements of the airtight compartment system of the Paks nuclear power plant and on the applied measuring principles is given. The measuring system and the selected measuring methods are evaluated. The characteristic features of the airtight system of the Paks nuclear power plant's 1st block and their effects on the measurement are mentioned.

  9. Integrated Ground Operations Demonstration Units Testing Plans and Status

    Science.gov (United States)

    Johnson, Robert G.; Notardonato, William U.; Currin, Kelly M.; Orozco-Smith, Evelyn M.

    2012-01-01

    Cryogenic propellant loading operations with their associated flight and ground systems are some of the most complex, critical activities in launch operations. Consequently, these systems and operations account for a sizeable portion of the life cycle costs of any launch program. NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite advances in cryogenics, system health management and command and control technologies. This project was developed to mature, integrate and demonstrate advancement in the current state of the art in these areas using two distinct integrated ground operations demonstration units (GODU): GODU Integrated Refrigeration and Storage (IRAS) and GODU Autonomous Control

  10. Combining polar organic chemical integrative samplers (POCIS) with toxicity testing to evaluate pesticide mixture effects on natural phototrophic biofilms

    International Nuclear Information System (INIS)

    Pesce, Stephane; Morin, Soizic; Lissalde, Sophie; Montuelle, Bernard; Mazzella, Nicolas

    2011-01-01

    Polar organic chemical integrative samplers (POCIS) are valuable tools in passive sampling methods for monitoring polar organic pesticides in freshwaters. Pesticides extracted from the environment using such methods can be used to toxicity tests. This study evaluated the acute effects of POCIS extracts on natural phototrophic biofilm communities. Our results demonstrate an effect of POCIS pesticide mixtures on chlorophyll a fluorescence, photosynthetic efficiency and community structure. Nevertheless, the range of biofilm responses differs according to origin of the biofilms tested, revealing spatial variations in the sensitivity of natural communities in the studied stream. Combining passive sampler extracts with community-level toxicity tests offers promising perspectives for ecological risk assessment. - Research highlights: → Polar organic chemical integrative samplers (POCIS) were used for monitoring polar organic pesticides in a contaminated river. → The acute effects of POCIS extracts were tested on natural phototrophic biofilm communities. → POCIS pesticide mixtures affected chlorophyll a fluorescence, photosynthetic efficiency and community structure. → Biofilm responses differed according to origin of the biofilms tested, revealing variations in the sensitivity of natural communities. → Combining passive sampler extracts with community-level toxicity tests offers promising perspectives for ecological risk assessment. - Pesticide mixtures extracted from POCIS can affect chl a fluorescence, photosynthetic efficiency and community structure of natural biofilms.

  11. Safety demonstration tests on pressure rise in ventilation system and blower integrity of a fuel-reprocessing plant

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Junichi; Suzuki, Motoe; Tsukamoto, Michio; Koike, Tadao; Nishio, Gunji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    In JAERI, the demonstration test was carried out as a part of safety researches of the fuel-reprocessing plant using a large-scale facility consist of cells, ducts, dumpers, HEPA filters and a blower, when an explosive burning due to a rapid reaction of thermal decomposition for solvent/nitric acid occurs in a cell of the reprocessing plant. In the demonstration test, pressure response propagating through the facility was measured under a blowing of air from a pressurized tank into the cell in the facility to elucidate an influence of pressure rise in the ventilation system. Consequently, effective pressure decrease in the facility was given by a configuration of cells and ducts in the facility. In the test, transient responses of HEPA filters and the blower by the blowing of air were also measured to confirm the integrity. So that, it is confirmed that HEPA filters and the blower under pressure loading were sufficient to maintain the integrity. The content described in this report will contribute to safety assessment of the ventilation system in the event of explosive burning in the reprocessing plant. (author)

  12. Energy Systems Integration Facility News | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems Integration Facility News Energy Systems Integration Facility Energy Dataset A massive amount of wind data was recently made accessible online, greatly expanding the Energy's National Renewable Energy Laboratory (NREL) has completed technology validation testing for Go

  13. Integrated assessment of pedestrian head impact protection in testing secondary safety and autonomous emergency braking.

    Science.gov (United States)

    Searson, D J; Anderson, R W G; Hutchinson, T P

    2014-02-01

    Pedestrian impact testing is used to provide information to the public about the relative level of protection provided by different vehicles to a struck pedestrian. Autonomous Emergency Braking (AEB) is a relatively new technology that aims to reduce the impact speed of such crashes. It is expected that vehicles with AEB will pose less harm to pedestrians, and that the benefit will come about through reductions in the number of collisions and a change in the severity of impacts that will still occur. In this paper, an integration of the assessment of AEB performance and impact performance is proposed based on average injury risk. Average injury risk is calculated using the result of an impact test and a previously published distribution of real world crash speeds. A second published speed distribution is used that accounts for the effects of AEB, and reduced average risks are implied. This principle allows the effects of AEB systems and secondary safety performance to be integrated into a single measure of safety. The results are used to examine the effect of AEB on Euro NCAP and ANCAP assessments using previously published results on the likely effect of AEB. The results show that, given certain assumptions about AEB performance, the addition of AEB is approximately the equivalent of increasing Euro NCAP test performance by one band, which corresponds to an increase in the score of 25% of the maximum. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Study on MHD instabilities in the CECI plasma device using Fourier probes

    International Nuclear Information System (INIS)

    Rosal, A.C.; Aso, Y.; Ueda, M.

    1991-01-01

    A magnetic diagnostics called Fourier analyser aiming to study MHD instabilities by Fourier series expansion of poloidal magnetic field for m ≤ 3 modes was developed and tested. The diagnostics will be used in the RFP (reversed field pinch) type toroidal plasma device. (M.C.K.)

  15. Integral comparison of library performance

    International Nuclear Information System (INIS)

    Mori, Takamasa

    2006-01-01

    The 2003-2004 activities of Reactor Integral Test WG under Subcommittee on Reactor Constants of Japanese Nuclear Data Committee are presented. During this period, the WG carried out integral tests of JENDL-3.3, ENDF/B-VI and JEF 2.2 (JEFF-3.0) for reactor applications. Some results of integral tests for other latest libraries, JEFF-3.1 and ENDF/B-VII are also presented. (author)

  16. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, 08

    Science.gov (United States)

    Valdez, A.

    2000-01-01

    This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).

  17. Relationship between the quality of children's handwriting and the Beery Buktenica developmental test of visuomotor integration after one year of writing tuition.

    Science.gov (United States)

    Duiser, Ivonne H F; van der Kamp, John; Ledebt, Annick; Savelsbergh, Geert J P

    2014-04-01

    We examined whether the three subtests of the Beery Buktenica developmental test of visuomotor integration predicted quality of handwriting across and within groups of boys and girls classified as proficient, at risk or non-proficient writers according to the Concise Assessment Scale for Children's Handwriting. The Beery Buktenica developmental test of visuomotor integration and the Concise Assessment Scale for Children's Handwriting tests were administered to 240 grade 2 children. Proficient writers scored better on the visuomotor integration subtest than non-proficient writers, while proficient and at risk writers scored better than non-proficient writers on the motor coordination subtest. No differences were found on the visual perception subtest. Girls were more often classified as proficient writers than boys, and they scored better on the motor coordination subtest. Across groups, regression indicated that gender and both the visuomotor integration subtest and the motor coordination subtest were significant predictors for the quality of handwriting (i.e., accounted for 17% of the variance). After one year of writing tuition, the visuomotor integration subtest (and to a lesser extent the motor coordination subtest) but not the visual perception subtest significant relates to quality of children's handwriting as measured with the Concise Assessment Scale for Children's Handwriting. However, the relatively little variance explained also points to other abilities and/or task constraints that underlie quality of handwriting. © 2013 Occupational Therapy Australia.

  18. Test and Diagnosis of Integrated Circuits

    OpenAIRE

    Bosio , Alberto

    2015-01-01

    The ever-increasing growth of the semiconductor market results in an increasing complexity of digital circuits. Smaller, faster, cheaper and low-power consumption are the main challenges in semiconductor industry. The reduction of transistor size and the latest packaging technology (i.e., System-On-a-Chip, System-In-Package, Trough Silicon Via 3D Integrated Circuits) allows the semiconductor industry to satisfy the latest challenges. Although producing such advanced circuits can benefit users...

  19. Oxy-Combustion Burner and Integrated Pollutant Removal Research and Development Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mark Schoenfield; Manny Menendez; Thomas Ochs; Rigel Woodside; Danylo Oryshchyn

    2012-09-30

    A high flame temperature oxy-combustion test facility consisting of a 5 MWe equivalent test boiler facility and 20 KWe equivalent IPR® was constructed at the Hammond, Indiana manufacturing site. The test facility was operated natural gas and coal fuels and parametric studies were performed to determine the optimal performance conditions and generated the necessary technical data required to demonstrate the technologies are viable for technical and economic scale-up. Flame temperatures between 4930-6120F were achieved with high flame temperature oxy-natural gas combustion depending on whether additional recirculated flue gases are added to balance the heat transfer. For high flame temperature oxy-coal combustion, flame temperatures in excess of 4500F were achieved and demonstrated to be consistent with computational fluid dynamic modeling of the burner system. The project demonstrated feasibility and effectiveness of the Jupiter Oxygen high flame temperature oxy-combustion process with Integrated Pollutant Removal process for CCS and CCUS. With these technologies total parasitic power requirements for both oxygen production and carbon capture currently are in the range of 20% of the gross power output. The Jupiter Oxygen high flame temperature oxy-combustion process has been demonstrated at a Technology Readiness Level of 6 and is ready for commencement of a demonstration project.

  20. Integrating Pregnancy Prevention Into an HIV Counseling and Testing Program in Pediatric Primary Care.

    Science.gov (United States)

    Wheeler, Noah J; Upadhya, Krishna K; Tawe, Marie-Sophie; Tomaszewski, Kathy; Arrington-Sanders, Renata; Marcell, Arik V

    2018-04-11

    Certified health educator (CHE)-based HIV counseling and testing typically focus on HIV and sexually transmitted infection (STI) prevention only. A quality improvement initiative examined integrating assessment of reproductive life plans, counseling about pregnancy prevention, and contraception referral into a CHE-based HIV testing program. Between February 2014 and January 2017, in one urban pediatric primary care clinic serving patients aged 0-25, CHEs assessed sexual history, HIV risk, short-term (i.e., the next 6-12 months) pregnancy desire, and current contraception method and satisfaction among patients aged 13-25 who had ever had vaginal sex, using a standardized questionnaire. Data were analyzed using a de-identified administrative dataset that also tracked referrals to initiate contraception and actual method initiation. Of 1,211 patients, most (96%) reported no short-term pregnancy or partner pregnancy desire. Use of less effective or no contraception, as well as method dissatisfaction, was common. A high proportion of female patients referred to new methods opted for more effective methods (62%) and initiated these methods (76%); a high proportion of male patients opted for receipt of condoms (67%). Patients reporting short-term pregnancy desire reported higher rates of previous pregnancy and STIs. Program findings highlight the potential benefit of integrating assessment for and counseling about pregnancy prevention in a CHE-based HIV testing program. This can more effectively address the needs of patients with concomitant risks of STI/HIV and unintended pregnancy, and link patients who do not desire pregnancy to more effective methods. Copyright © 2018 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.