WorldWideScience

Sample records for integrated protection system

  1. Digital integrated protection system

    International Nuclear Information System (INIS)

    Savornin, M.; Furet, M.

    1978-01-01

    As a result of technological progress it is now possible to achieve more elaborate protection functions able to follow more closely the phenomena to be supervised. For this reason the CEA, Framatome and Merlin/Gerin/CERCI have undertaken in commonn to develop a Digital Integrated Protection System (D.I.P.S.). This system is designed with the following aims: to improve the safety of the station, . to improve its availability, . to facilitate installation, . to facilitate tests and maintenance. The main characteristics adopted are: . possibilities of obtaining more elaborate monitoring and protection algorithm treatments, . order 4 redundancy of transducers, associated instruments and signal processing, . possibility of inhibiting part of the protection system, . standardisation of equipment, physical and electrical separation of redundant units, . use of multiplexed connections, . automation of tests. Four flow charts are presented: - DIPS with four APUP (Acquisition and Processing Unit for Protection) - APUP - LSU (Logic Safeguard Unit), number LSU corresponding to number fluidic safeguard circuits, - structure of a function unit, - main functions of the APUP [fr

  2. Integrated crop protection as a system approach

    OpenAIRE

    Haan, de, J.J.; Wijnands, F.G.; Sukkel, W.

    2005-01-01

    New farming systems in vegetable production are required as demands for high quality products that do not pollute the environment are rising, and production risks are large and incomes low. The methodology of prototyping new systems is described, especially the themes, parameters and target values connected to integrated crop protection. The role of integrated crop protection in prototyping new systems is discussed. The results of twenty years working with this prototyping methodology are pre...

  3. An integrated system for physical protection

    International Nuclear Information System (INIS)

    Kumar, Ranajit

    2001-01-01

    An Integrated Physical Protection System (IPPS) was developed for the consolidation of all sub systems, sensors and elements related to physical protection for an efficient and effective security environment of a facility. An effective physical protection system discharges the functions of detection, delay, communication, response, access control etc. IPPS performs, controls and monitors all the above functionality and helps in taking quick action on occurrence of unusual incidents by instantly reporting the incident in easily understandable audio, video, graphical and textual format and also by initiating automatic interactions among sub-systems

  4. A demonstrator for an integrated subway protection system

    Science.gov (United States)

    Detoma, E.; Capetti, P.; Casati, G.; Billington, S.

    2008-04-01

    In 2006 SEPA has carried on the installation and tests of a demonstrator for an integrated subway protection system at a new subway station in the Naples, Italy) metropolitan area. Protection of a subway system is a difficult task given the amount of passengers transported every day. The demonstrator has been limited to non-intrusive detection techniques not to impair the passenger flow into the station. The demonstrator integrates several technologies and products that have been developed by SEPA or are already available on the market (MKS Instruments,...). The main purpose is to provide detection capabilities for attempts to introduce radioactive substances in the subway station, in order to foil possible attempts to place a dirty bomb, and threat detection and identification following release of chemical agents. The system integrates additional sensors such as video surveillance cameras and air flow sensing to complement the basic sensors suite. The need to protect sensitive installations such as subway stations has been highlighted by the series of terroristics actions carried out in recent years in the subway in London. However, given the number of passengers of a metro system, it is impossible to propose security techniques operating in ways similar to the screening of passengers in airports. Passengers screening and threat detection and identification must be quick, non-intrusive and capable of screening a large number of passengers to be applicable to mass transit systems. In 2005 SEPA, a small company operating in the field of trains video-surveillance systems and radiation detectors, started developing an integrated system to provide a comprehensive protection to subway stations, based on ready available or off-the-shelf components in order to quickly develop a reliable system with available technology. We ruled out at the beginning any new development in order to speed up the fielding of the system in less than one year. The system was developed with

  5. An integrated numerical protection system (SPIN)

    International Nuclear Information System (INIS)

    Savornin, J.L.; Bouchet, J.M.; Furet, J.L.; Jover, P.; Sala, A.

    1978-01-01

    Developments in technology have now made it possible to perform more sophisticated protection functions which follow more closely the physical phenomena to be monitored. For this reason the Commissariat a l'energie atomique, Merlin-Gerin, Cerci and Framatome have embarked on the joint development of an Integrated Numerical Protection System (SPIN) which will fulfil this objective and will improve the safety and availability of power stations. The system described involves the use of programmed numerical techniques and a structure based on multiprocessors. The architecture has a redundancy of four. Throughout the development of the project the validity of the studies was confirmed by experiments. A first numerical model of a protection function was tested in the laboratory and is now in operation in a power station. A set of models was then introduced for checking the main components of the equipment finally chosen prior to building and testing a prototype. (author)

  6. Relay Protection and Automation Systems Based on Programmable Logic Integrated Circuits

    International Nuclear Information System (INIS)

    Lashin, A. V.; Kozyrev, A. V.

    2015-01-01

    One of the most promising forms of developing the apparatus part of relay protection and automation devices is considered. The advantages of choosing programmable logic integrated circuits to obtain adaptive technological algorithms in power system protection and control systems are pointed out. The technical difficulties in the problems which today stand in the way of using relay protection and automation systems are indicated and a new technology for solving these problems is presented. Particular attention is devoted to the possibility of reconfiguring the logic of these devices, using programmable logic integrated circuits

  7. Integrated nuclear and radiation protection systems

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, V.; Cerga, V.; Pirvu, V.; Badea, E.

    1993-01-01

    A multifunctional radiation monitoring equipment, flexible and capable to meet virtually environmental radiation monitoring, activity measurement and computational requirements, for nuclear laboratories has been designed. It can be used as a radiation protection system, for radionuclide measurement in isotope laboratories, nuclear technology, health physics and nuclear medicine, nuclear power stations and nuclear industry. The equipment is able to measure, transmit and record gamma dose rate and isotope activities. Other parameters and functions are optionally available, such as: self-contained alarm level, system self-test, dose integrator, syringe volume calculation for a given dose corrected for decay, calibration factor, 99 Mo assays performing and background subtraction

  8. Joint force protection advanced security system (JFPASS) "the future of force protection: integrate and automate"

    Science.gov (United States)

    Lama, Carlos E.; Fagan, Joe E.

    2009-09-01

    The United States Department of Defense (DoD) defines 'force protection' as "preventive measures taken to mitigate hostile actions against DoD personnel (to include family members), resources, facilities, and critical information." Advanced technologies enable significant improvements in automating and distributing situation awareness, optimizing operator time, and improving sustainability, which enhance protection and lower costs. The JFPASS Joint Capability Technology Demonstration (JCTD) demonstrates a force protection environment that combines physical security and Chemical, Biological, Radiological, Nuclear, and Explosive (CBRNE) defense through the application of integrated command and control and data fusion. The JFPASS JCTD provides a layered approach to force protection by integrating traditional sensors used in physical security, such as video cameras, battlefield surveillance radars, unmanned and unattended ground sensors. The optimization of human participation and automation of processes is achieved by employment of unmanned ground vehicles, along with remotely operated lethal and less-than-lethal weapon systems. These capabilities are integrated via a tailorable, user-defined common operational picture display through a data fusion engine operating in the background. The combined systems automate the screening of alarms, manage the information displays, and provide assessment and response measures. The data fusion engine links disparate sensors and systems, and applies tailored logic to focus the assessment of events. It enables timely responses by providing the user with automated and semi-automated decision support tools. The JFPASS JCTD uses standard communication/data exchange protocols, which allow the system to incorporate future sensor technologies or communication networks, while maintaining the ability to communicate with legacy or existing systems.

  9. System level ESD protection

    CERN Document Server

    Vashchenko, Vladislav

    2014-01-01

    This book addresses key aspects of analog integrated circuits and systems design related to system level electrostatic discharge (ESD) protection.  It is an invaluable reference for anyone developing systems-on-chip (SoC) and systems-on-package (SoP), integrated with system-level ESD protection. The book focuses on both the design of semiconductor integrated circuit (IC) components with embedded, on-chip system level protection and IC-system co-design. The readers will be enabled to bring the system level ESD protection solutions to the level of integrated circuits, thereby reducing or completely eliminating the need for additional, discrete components on the printed circuit board (PCB) and meeting system-level ESD requirements. The authors take a systematic approach, based on IC-system ESD protection co-design. A detailed description of the available IC-level ESD testing methods is provided, together with a discussion of the correlation between IC-level and system-level ESD testing methods. The IC-level ESD...

  10. Concepts on integration of physical protection and material accounting functions in a safeguards system

    International Nuclear Information System (INIS)

    Reynolds, D.A.

    1981-01-01

    Concepts on integration of physical protection and material accounting systems to enhance overall safeguards capability are developed and presented. Integration is approached by coordinating all safeguards information through a safeguards coordination center. This center represents a higher level in a communication, data-processing, and decision-making structure which is needed for efficient real-time operation of the integrated system. The safeguards coordination center functions to assess alarm and warning data required to resolve threats in the safeguards system, coordinate information and interaction involving the material accounting, physical protection, and facility monitoring and control systems, and present a single unified interface for interaction with facility management, facility operations, safeguards system personnel, and response forces

  11. Concepts on integration of physical protection and material accounting functions in a safeguards system

    International Nuclear Information System (INIS)

    Reynolds, D.A.

    1981-01-01

    Concepts on integration of physical protection and material accounting systems to enhance overall safeguards capability are developed and presented. These concepts identify ways in which material accounting systems can be used to enable effective monitoring of authorized movement of nuclear material through physical protection boundaries. Concepts are also discussed for monitoring user access to nuclear material and for tagging user identification to material accounting transactions through physical protection functions. These result in benefits in detecting diversion and in positively tracing material movement. Finally, coordination of safeguards information from both subsystems in such an integrated system through a safeguards coordination center is addressed with emphasis on appropriate response in case of discrepancies

  12. A Multiagent System-Based Protection and Control Scheme for Distribution System With Distributed-Generation Integration

    DEFF Research Database (Denmark)

    Liu, Z.; Su, Chi; Hoidalen, Hans

    2017-01-01

    In this paper, a multi agent system (MAS) based protection and control scheme is proposed to deal with diverse operation conditions in distribution system due to distributed generation (DG) integration. Based on cooperation between DG controller and relays, an adaptive protection and control...... algorithm is designed on converter based wind turbine DG to limit the influence of infeed fault current. With the consideration of DG control modes, an adaptive relay setting strategy is developed to help protective relays adapt suitable settings to different operation conditions caused by the variations...

  13. A management system integrating radiation protection and safety supporting safety culture in the hospital

    International Nuclear Information System (INIS)

    Almen, A.; Lundh, C.

    2015-01-01

    Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system. The main experience from developing a management system is that it is possible to create a vast number of common policies and routines for the whole hospital, resulting in a cost-efficient system. One of the key benefits is the involvement of management at all levels, including the hospital director. Furthermore, a transparent system will involve staff throughout the organisation as well. A management system supports a common view on what should be done, who should do it and how the activities are reviewed. An integrated management system for radiation protection and safety includes key elements supporting a safety culture. (authors)

  14. Reactor protection system design using application specific integrated circuits

    International Nuclear Information System (INIS)

    Battle, R.E.; Bryan, W.L.; Kisner, R.A.; Wilson, T.L. Jr.

    1992-01-01

    Implementing reactor protection systems (RPS) or other engineering safeguard systems with application specific integrated circuits (ASICs) offers significant advantages over conventional analog or software based RPSs. Conventional analog RPSs suffer from setpoints drifts and large numbers of discrete analog electronics, hardware logic, and relays which reduce reliability because of the large number of potential failures of components or interconnections. To resolve problems associated with conventional discrete RPSs and proposed software based RPS systems, a hybrid analog and digital RPS system implemented with custom ASICs is proposed. The actual design of the ASIC RPS resembles a software based RPS but the programmable software portion of each channel is implemented in a fixed digital logic design including any input variable computations. Set point drifts are zero as in proposed software systems, but the verification and validation of the computations is made easier since the computational logic an be exhaustively tested. The functionality is assured fixed because there can be no future changes to the ASIC without redesign and fabrication. Subtle error conditions caused by out of order evaluation or time dependent evaluation of system variables against protection criteria are eliminated by implementing all evaluation computations in parallel for simultaneous results. On- chip redundancy within each RPS channel and continuous self-testing of all channels provided enhanced assurance that a particular channel is available and faults are identified as soon as possible for corrective actions. The use of highly integrated ASICs to implement channel electronics rather than the use of discrete electronics greatly reduces the total number of components and interconnections in the RPS to further increase system reliability. A prototype ASIC RPS channel design and the design environment used for ASIC RPS systems design is discussed

  15. Integrated Thermal Protection Systems and Heat Resistant Structures

    Science.gov (United States)

    Pichon, Thierry; Lacoste, Marc; Glass, David E.

    2006-01-01

    In the early stages of NASA's Exploration Initiative, Snecma Propulsion Solide was funded under the Exploration Systems Research & Technology program to develop integrated thermal protection systems and heat resistant structures for reentry vehicles. Due to changes within NASA's Exploration Initiative, this task was cancelled early. This presentation provides an overview of the work that was accomplished prior to cancellation. The Snecma team chose an Apollo-type capsule as the reference vehicle for the work. They began with the design of a ceramic aft heatshield (CAS) utilizing C/SiC panels as the capsule heatshield, a C/SiC deployable decelerator and several ablators. They additionally developed a health monitoring system, high temperature structures testing, and the insulation characterization. Though the task was pre-maturely cancelled, a significant quantity of work was accomplished.

  16. Application of the integrated safety assessment methodology to the protection of electric systems

    International Nuclear Information System (INIS)

    Hortal, Javier; Izquierdo, Jose M.

    1996-01-01

    The generalization of classical techniques for risk assessment incorporating dynamic effects is the main objective of the Integrated Safety Assessment Methodology, as practical implementation of Protection Theory. Transient stability, contingency analysis and protection setpoint verification in electric power systems are particularly appropriate domains of application, since the coupling of reliability and dynamic analysis in the protection assessment process is being increasingly demanded. Suitable techniques for dynamic simulation of sequences of switching events in power systems are derived from the use of quasi-linear equation solution algorithms. The application of the methodology, step by step, is illustrated in a simple but representative example

  17. A framework for exploring integrated learning systems for the governance and management of public protected areas.

    Science.gov (United States)

    Nkhata, Bimo Abraham; Breen, Charles

    2010-02-01

    This article discusses how the concept of integrated learning systems provides a useful means of exploring the functional linkages between the governance and management of public protected areas. It presents a conceptual framework of an integrated learning system that explicitly incorporates learning processes in governance and management subsystems. The framework is premised on the assumption that an understanding of an integrated learning system is essential if we are to successfully promote learning across multiple scales as a fundamental component of adaptability in the governance and management of protected areas. The framework is used to illustrate real-world situations that reflect the nature and substance of the linkages between governance and management. Drawing on lessons from North America and Africa, the article demonstrates that the establishment and maintenance of an integrated learning system take place in a complex context which links elements of governance learning and management learning subsystems. The degree to which the two subsystems are coupled influences the performance of an integrated learning system and ultimately adaptability. Such performance is largely determined by how integrated learning processes allow for the systematic testing of societal assumptions (beliefs, values, and public interest) to enable society and protected area agencies to adapt and learn in the face of social and ecological change. It is argued that an integrated perspective provides a potentially useful framework for explaining and improving shared understanding around which the concept of adaptability is structured and implemented.

  18. Defense-in-depth and diversity assessment of the RESAR-414 Integrated Protection System

    International Nuclear Information System (INIS)

    1979-01-01

    This report discusses the defense-in-depth and diversity principles as they apply to safety related instrumentation and presents guidelines which can be used to assess the degree to which the designs of complex, interconnected safety systems conform to these principles. These guidelines are based on the use of the block concept, an approach in which the components and modules of the system are aggregated into a small number of functional units, or blocks, to simplify the analysis. It is believed that the use of the block concept and the guidelines will result in a conservative assessment of the capability of such systems to function when subjected to postulated to common-mode failures. A preliminary assessment of the RESAR-414 Integrated Protection System by means of the guidelines is also presented. The results of this assessment support the conclusion that, for purposes of a preliminary design approval, the RESAR-414 Integrated Protection System is acceptable. However, the assessment, has also resulted in requirements for additional analyses and tests, the results of which must demonstrate conformance to the guidelines prior to the issuance of a Final Design Approval

  19. Development of Integrated Code for Risk Assessment (INCORIA) for Physical Protection System

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Seo, Hyung Min; Yoo, Ho Sik

    2010-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent human attacks. Among critical facilities, nuclear facilities and nuclear weapon sites require the highest level of PPS. After the September 11, 2001 terrorist attacks, international communities, including the IAEA, have made substantial efforts to protect nuclear material and nuclear facilities. The international flow on nuclear security is using the concept or risk assessment. The concept of risk assessment is firstly devised by nuclear safety people. They considered nuclear safety including its possible risk, which is the frequency of failure and possible consequence. Nuclear security people also considers security risk, which is the frequency of threat action, vulnerability, and consequences. The concept means that we should protect more when the credible threat exists and the possible radiological consequence is high. Even if there are several risk assessment methods of nuclear security, the application needs the help of tools because of a lot of calculation. It's also hard to find tools for whole phase of risk assessment. Several codes exist for the part of risk assessment. SAVI are used for vulnerability of PPS. Vital area identification code is used for consequence analysis. We are developing Integrated Code for Risk Assessment (INCORIA) to apply risk assessment methods for nuclear facilities. INCORIA evaluates PP-KINAC measures and generation tools for threat scenario. PP-KINAC is risk assessment measures for physical protection system developed by Hosik Yoo and is easy to apply. A threat scenario tool is used to generate threat scenario, which is used as one of input value to PP-KINAC measures

  20. Fire protection system management in nuclear facilities: strengthening factor of integrated management system - a case study

    International Nuclear Information System (INIS)

    Santos, Joao Regis dos

    2005-01-01

    The present study investigated and analyzed the importance of a system of integrated safety manage, environment and health in a nuclear installation, having as perspective, the fire protection manage. The inquiry was made using a qualitative research involving a case study, where the considered environment was the Reconversion and UO 2 Plant of the Industrias Nucleares do Brasil (INB), located in Resende, Rio de Janeiro and the studied population, the managers and the staff directly involved with the aspects related to the safety of the industrial complex of the related company. The motivation for the research was the search of a bigger interaction of the questions related to the safety, environment and health in the nuclear industry having, as axle of the investigation, the fire protection. As a result, it was observed that in a nuclear installation, although dealing with diversified safety processes, integration is possible and necessary, since there are more reasons for integration than otherwise. (author)

  1. Integral isolation valve systems for loss of coolant accident protection

    Science.gov (United States)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  2. Buffer moisture protection system

    International Nuclear Information System (INIS)

    Ritola, J.; Peura, J.

    2013-11-01

    With the present knowledge, bentonite blocks have to be protected from the air relative humidity and from any moisture leakages in the environment that might cause swelling of the bentonite blocks during the 'open' installation phase before backfilling. The purpose of this work was to design the structural reference solution both for the bottom of the deposition hole and for the buffer moisture protection and dewatering system with their integrated equipment needed in the deposition hole. This report describes the Posiva's reference solution for the buffer moisture protection system and the bottom plate on basis of the demands and functional requirements set by long-term safety. The reference solution with structural details has been developed in research work made 2010-2011. The structural solution of the moisture protection system has not yet been tested in practice. On the bottom of the deposition hole a copper plate which protects the lowest bentonite block from the gathered water is installed straight to machined and even rock surface. The moisture protection sheet made of EPDM rubber is attached to the copper plate with an inflatable seal. The upper part of the moisture protection sheet is fixed to the collar structures of the lid which protects the deposition hole in the disposal tunnel. The main function of the moisture protection sheet is to protect bentonite blocks from the leaking water and from the influence of the air humidity at their installation stage. The leaking water is controlled by the dewatering and alarm system which has been integrated into the moisture protection liner. (orig.)

  3. Depth protection system

    International Nuclear Information System (INIS)

    Arita, Setsuo; Izumi, Shigeru; Suzuki, Satoru; Noguchi, Atomi.

    1988-01-01

    Purpose: To previously set a nuclear reactor toward safety side by the reactor scram if an emergency core cooling system is failed to operate. Constitution If abnormality occurs in an emergency core cooling system or an aqueous boric acid injection system, a reactor protection system is operated and, if the reactor protection system shows an abnormal state, a control rod withdrawal inhibition system is operated as a fundamental way. For instance, when the driving power source voltage for the emergency core cooling system is detected and, if it is lower than a predetermined value, the reactor protection system is operated. Alternatively, if the voltage goes lower than the predetermined value, the control rod withdrawal is inhibited. In addition, stopping for the feedwater system is inhibited. Further, integrity of the driving means for the emergency core cooling system is positively checked and the protection function is operated depending on the result of check. Since the nuclear reactor can be set toward the safety side even if the voltage for the driving power source of the aqueous boric acid injection system is lower than a predetermined value, the reactor safety can further be improved. (Horiuchi, T.)

  4. Radiological protection system in the era of nuclear renaissance expectation for development of radiological protection system

    International Nuclear Information System (INIS)

    Toyomatsu, Hideki

    2008-01-01

    The current radiological protection system, which was established mainly by the ICRP and UNSCEAR, has contributed to the prevention of potential radiological health hazards, and has been a fundamental concept during the development of nuclear energy. Through a detailed discussion regarding the new ICRP recommendations, the world nuclear industry has reached a consensus that the current radiological protection system keeps its integrity in principle although it involves some remaining issues, such as the disposal of radioactive waste. In order to maximize the advantages of nuclear energy while keeping the integrity of radiological protection system, it is essential to address the characteristics of radiation, which is specific to nuclear energy, so that nuclear energy can coexist with other energy sources. The three basic principles of radiological protection (i.e., justification, optimization and dose limits), which were completed in the 1990 recommendations of ICRP, should be retained as the basic concepts for the future radiological protection system in order to maintain the continuity and consistency of the radiological protection system. The radiological protection system can be furthermore developed only by combining the above three principles with best practices extracted from utilities' field experience. The significant reduction of radiation exposures received by members of the public and radiation workers in the field has resulted from the efforts by the world utilities to achieve the optimization. In order to correctly apply the theory to the work practices, it is essential to see how the theory is practically used in the field. Such a process should be also emphasized in the revision work of the IAEA Basic Safety Standards (BSS), which is currently under progress. Integrating the theory in the work practices is the key to the true development of nuclear renaissance, which could lead to the establishment of the nuclear safety regime. (author)

  5. Issues around radiological protection of the environment and its integration with protection of humans: promoting debate on the way forward

    International Nuclear Information System (INIS)

    Brownless, G P

    2007-01-01

    This paper explores issues to consider around integrating direct, explicit protection of the environment into the current system of radiological protection, which is focused on the protection of humans. Many issues around environmental radiological protection have been discussed, and ready-to-use toolboxes have been constructed for assessing harm to non-human biota, but it is not clear how (or even if) these should be fitted into the current system of protection. Starting from the position that the current approach to protecting the environment (namely that it follows from adequately protecting humans) is generally effective, this paper considers how explicit radiological protection of the environment can be integrated with the current system, through developing a 'worked example' of how this could be done and highlighting issues peculiar to protection of the environment. The aim of the paper is to promote debate on this topic, with the ultimate aim of ensuring that any changes to the system are consensual and robust

  6. THE ECONOMIC EFFICIENCY OF THE INTEGRATED SYSTEM OF PROTECTION OF WHITE CABBAGE

    Directory of Open Access Journals (Sweden)

    B. U. Misrieva

    2017-01-01

    Full Text Available The climatic conditions of the Derbent district of the Republic of Dagestan are favorable for seed-growing cabbage of white-cabbage and other varieties by a nonstop method. In the complex of measures to increase the efficiency of production of cabbage seeds, pest and disease control  plays an important  role. The article proves the application of a new approach to the protection system of testes of white cabbage. On the basis of long-term phytosanitary   monitoring   and   biocenotic   principles, which  allow differentiating  the use of  protective  equipment in each specific case, an integrated system of protection of testes of cabbage from the main pests in the conditions  of the south of Russia has been developed. New progressive methods in the implementation of basic technological  processes are economically justified.  The introduction of the system ensured a significant increase in the yield of testes of white cabbage and the profitability of  seed production.  For each ruble of  expenses for crop protection, 8.1 rubles of additional income was received. Applied in FIC VNIIR AES testicles of cabbage allowed  to  harvest 190 kg of  additional  yield of  hybrid seeds from each hectare. The amount of realization of the additional harvest was 114,000 rubles. The recoupment of  costs  in  terms  of  the  ruble  costs  is  29.5  rubles. Reducing the  pesticide  load on  agrocenosis, yielded a yield with good quality characteristics. The difference in germination was 5-6% higher when using satellites. The fulfillment of the seeds also depended on the protection system. Thus, the mass of 1000 seeds when using the AES of testes of cabbage in the F1 Hybrid Extra was 4.68 g, while the schedule of treatment was 3.83 g.

  7. Kinetic Integrated Thermal Protection System (KnITPS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Use the flexibility and shape formation possibilities inherent in knitting to form thermal protection systems that can be custom fitted to a heat shield carrier...

  8. Pressure Shell Approach to Integrated Environmental Protection

    Science.gov (United States)

    Kennedy, Kriss J.

    2011-01-01

    The next generation of exploration mission human systems will require environmental protection such as radiation protection that is effective and efficient. In order to continue human exploration, habitat systems will require special shells to protect astronauts from hostile environments. The Pressure Shell Approach to integrated environmental (radiation) protection is a multi-layer shell that can be used for multifunctional environmental protection. Self-healing, self-repairing nano technologies and sensors are incorporated into the shell. This shell consists of multiple layers that can be tailored for specific environmental protection needs. Mainly, this innovation focuses on protecting crew from exposure to micrometeorites, thermal, solar flares, and galactic cosmic ray (GCR) radiation. The Pressure Shell Approach consists of a micrometeoroid and secondary ejecta protection layer; a thin, composite shell placed in between two layers that is non-structural; an open cavity layer that can be filled with water, regolith, or polyethylene foam; a thicker composite shell that is a structural load bearing that is placed between two layers; and a bladder coating on the interior composite shell. This multi-layer shell creates an effective radiation protection system. Most of its layers can be designed with the materials necessary for specific environments. In situ materials such as water or regolith can be added to the shell design for supplemental radiation protection.

  9. Speech understanding in noise with integrated in-ear and muff-style hearing protection systems

    Directory of Open Access Journals (Sweden)

    Sharon M Abel

    2011-01-01

    Full Text Available Integrated hearing protection systems are designed to enhance free field and radio communications during military operations while protecting against the damaging effects of high-level noise exposure. A study was conducted to compare the effect of increasing the radio volume on the intelligibility of speech over the radios of two candidate systems, in-ear and muff-style, in 85-dBA speech babble noise presented free field. Twenty normal-hearing, English-fluent subjects, half male and half female, were tested in same gender pairs. Alternating as talker and listener, their task was to discriminate consonant-vowel-consonant syllables that contrasted either the initial or final consonant. Percent correct consonant discrimination increased with increases in the radio volume. At the highest volume, subjects achieved 79% with the in-ear device but only 69% with the muff-style device, averaged across the gender of listener/talker pairs and consonant position. Although there was no main effect of gender, female listener/talkers showed a 10% advantage for the final consonant and male listener/talkers showed a 1% advantage for the initial consonant. These results indicate that normal hearing users can achieve reasonably high radio communication scores with integrated in-ear hearing protection in moderately high-level noise that provides both energetic and informational masking. The adequacy of the range of available radio volumes for users with hearing loss has yet to be determined.

  10. Assessment of Integrated Pedestrian Protection Systems with Autonomous Emergency Braking (AEB) and Passive Safety Components.

    Science.gov (United States)

    Edwards, Mervyn; Nathanson, Andrew; Carroll, Jolyon; Wisch, Marcus; Zander, Oliver; Lubbe, Nils

    2015-01-01

    Autonomous emergency braking (AEB) systems fitted to cars for pedestrians have been predicted to offer substantial benefit. On this basis, consumer rating programs-for example, the European New Car Assessment Programme (Euro NCAP)-are developing rating schemes to encourage fitment of these systems. One of the questions that needs to be answered to do this fully is how the assessment of the speed reduction offered by the AEB is integrated with the current assessment of the passive safety for mitigation of pedestrian injury. Ideally, this should be done on a benefit-related basis. The objective of this research was to develop a benefit-based methodology for assessment of integrated pedestrian protection systems with AEB and passive safety components. The method should include weighting procedures to ensure that it represents injury patterns from accident data and replicates an independently estimated benefit of AEB. A methodology has been developed to calculate the expected societal cost of pedestrian injuries, assuming that all pedestrians in the target population (i.e., pedestrians impacted by the front of a passenger car) are impacted by the car being assessed, taking into account the impact speed reduction offered by the car's AEB (if fitted) and the passive safety protection offered by the car's frontal structure. For rating purposes, the cost for the assessed car is normalized by comparing it to the cost calculated for a reference car. The speed reductions measured in AEB tests are used to determine the speed at which each pedestrian in the target population will be impacted. Injury probabilities for each impact are then calculated using the results from Euro NCAP pedestrian impactor tests and injury risk curves. These injury probabilities are converted into cost using "harm"-type costs for the body regions tested. These costs are weighted and summed. Weighting factors were determined using accident data from Germany and Great Britain and an independently

  11. River Protection Project Integrated safety management system phase II verification review plan - 7/29/99

    International Nuclear Information System (INIS)

    SHOOP, D.S.

    1999-01-01

    The purpose of this review is to verify the implementation status of the Integrated Safety Management System (ISMS) for the River Protection Project (RPP) facilities managed by Fluor Daniel Hanford, Inc. (FDH) and operated by Lockheed Martin Hanford Company (LMHC). This review will also ascertain whether within RPP facilities and operations the work planning and execution processes are in place and functioning to effectively protect the health and safety of the workers, public, environment, and federal property over the RPP life cycle. The RPP ISMS should support the Hanford Strategic Plan (DOERL-96-92) to safely clean up and manage the site's legacy waste and deploy science and technology while incorporating the ISMS central theme to ''Do work safely'' and protect human health and the environment

  12. Integration of the environment into the system of radiation protection

    International Nuclear Information System (INIS)

    Higley, K.

    2018-01-01

    In 2005 the International Commission on Radiological Protection (ICRP) embarked on an effort to ensure that the system for environmental radiological protection would be reconcilable with that for radiological protection of man, and with the approaches used for protection of the environment from other potential hazards

  13. Agroenergy production from biomass in integrated agroforestry systems: an alternative to achieve food security and environmental protection

    International Nuclear Information System (INIS)

    Suárez, J.; Martín, G. J.

    2010-01-01

    The objective of this paper is to offer considerations about agroenergy production from biomass in integrated agroforestry systems. At present, worldwide, marked by a group of hazards that threaten human existence, there is a challenge mainly in the rural context: how can the coexistence of agroenergy, food security and environmental protection be achieved?, in the presence of climate changes, environmental degradation, food crises and the growing biofuels vs food contradiction, generated by a senseless policy for obtaining first-generation agrofuels from large extensions of food monocrops, which is morally rejectable. Biofuels are also considered an ecological alternative to fossil fuels, because of their reduction capacity in the emission of greenhouse gasses and because they promote the development of rural communities in southern countries; this is enhanced in integrated agroforestry systems, in which biofuels, of first as well as second generation, can be produced, especially with the application of the concept of biorefinery which allows converting biomass into many products, which total added value can be higher than the one generated by fossil fuels. International projects, which promote integrated and sustainable food and energy production in the context of agroforestry integrated systems, at local scale, contribute to this purpose. The authors consider that the execution of projects and experiences about agroenergy has the main objective of achieving energetic sustainability and food security at local scale, in rural areas, taking into account environmental protection. (author)

  14. Implementation of FPGA-Based Diverse Protection System

    International Nuclear Information System (INIS)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min

    2015-01-01

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails

  15. Implementation of FPGA-Based Diverse Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min [KEPCO Engineering and Construction Company Inc., Daejeon (Korea, Republic of)

    2015-10-15

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails.

  16. Design and testing of integrated circuits for reactor protection channels

    International Nuclear Information System (INIS)

    Battle, R.E.; Vandermolen, R.I.; Jagadish, U.; Swail, B.K.; Naser, J.

    1995-01-01

    Custom and semicustom application-specific integrated circuit design and testing methods are investigated for use in research and commercial nuclear reactor safety systems. The Electric Power Research Institute and Oak Ridge National Laboratory are working together through a cooperative research and development agreement to apply modern technology to a nuclear reactor protection system. The purpose of this project is to demonstrate to the nuclear industry an alternative approach for new or upgrade reactor protection and safety system signal processing and voting logic. Motivation for this project stems from (1) the difficulty of proving that software-based protection systems are adequately reliable, (2) the obsolescence of the original equipment, and (3) the improved performance of digital processing. A demonstration model for protection system of PWR reactor has been designed and built

  17. Programmed system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Jover, Pierre.

    1980-06-01

    The progress in the field of microprocessors and large scale integration circuits, have incited to introduce this new technologies into nuclear power plant protection system. The hardware and software design principles are briefly listed; then, a quad-redundant protection system for 1300 MWe PWR, developed in France is described [fr

  18. Controls and Machine Protection Systems

    CERN Document Server

    Carrone, E.

    2016-01-01

    Machine protection, as part of accelerator control systems, can be managed with a 'functional safety' approach, which takes into account product life cycle, processes, quality, industrial standards and cybersafety. This paper will discuss strategies to manage such complexity and the related risks, with particular attention to fail-safe design and safety integrity levels, software and hardware standards, testing, and verification philosophy. It will also discuss an implementation of a machine protection system at the SLAC National Accelerator Laboratory's Linac Coherent Light Source (LCLS).

  19. Control system integration

    CERN Document Server

    Shea, T J

    2008-01-01

    This lecture begins with a definition of an accelerator control system, and then reviews the control system architectures that have been deployed at the larger accelerator facilities. This discussion naturally leads to identification of the major subsystems and their interfaces. We shall explore general strategies for integrating intelligent devices and signal processing subsystems based on gate arrays and programmable DSPs. The following topics will also be covered: physical packaging; timing and synchronization; local and global communication technologies; interfacing to machine protection systems; remote debugging; configuration management and source code control; and integration of commercial software tools. Several practical realizations will be presented.

  20. Design and testing of integrated circuits for reactor protection channels

    International Nuclear Information System (INIS)

    Battle, R.E.; Vandermolen, R.I.; Jagadish, U.; Swail, B.K.; Naser, J.; Rana, I.

    1995-01-01

    Custom and semicustom application-specific integrated circuit design and testing methods are investigated for use in research and commercial nuclear reactor safety systems. The Electric Power Research Institute and Oak Ridge National Laboratory are working together through a cooperative research and development agreement to apply modern technology to a nuclear reactor protection system. Purpose of this project is to demonstrate to the nuclear industry an alternative approach for new or upgrade reactor protection and safety system signal processing and voting logic. Motivation for this project stems from (1) the difficulty of proving that software-based protection systems are adequately reliable, (2) the obsolescence of the original equipment, and (3) the improved performance of digital processing

  1. Multi Agent System Based Adaptive Protection for Dispersed Generation Integrated Distribution Systems

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Bak, Claus Leth

    2013-01-01

    The increasing penetration of dispersed generation (DG) brings challenges to conventional protection approaches of distribution system, mainly due to bi-directional power flow and variable fault current contribution from different generation technology-based DG units. Moreover, the trend......) is proposed. The adaptive protection intelligently adopts suitable settings for the variation of fault current from diversified DG units. Furthermore, the structure of mobile MAS with additional flexibility is capable of adapting the changes of system topology in a short period, e.g. radial/meshed, grid...

  2. 46 CFR 111.50-2 - Systems integration.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Systems integration. 111.50-2 Section 111.50-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-2 Systems integration. The electrical characteristics of each...

  3. Westinghouse integrated protection system. An overview of the software design and maintenance features

    International Nuclear Information System (INIS)

    Gibson, R.J.

    1995-01-01

    The Westinghouse Integrated Protection System was designed with the goal of providing a system which can be easily verified, validated, and maintained. The software design and structure promote the ease of translation from functional requirements to applications function software while also improving the ability to verify and maintain the applications function software. The use of independent, reusable, common functions software modules focuses the design, verification, and validation of the software and reduces the likelihood of errors occurring during the application and maintenance of the software. The simple continuous loop method of operation used throughout the IPS provides a standard deterministic method of operation. The IPS design also incorporates the use of embedded self-diagnostics to perform continuous hardware oriented tests of the system and the use of an independent subsystem to automatically perform a functional test of the system. Maintenance interfaces also exist to readily identify and locate faults as well as providing other maintenance capabilities. These testing and maintenance features enhance the overall reliability and availability of the system. (orig.) (2 refs., 2 figs.)

  4. Establishing an Information Security System related to Physical Protection

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Yoo, Ho Sik

    2009-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent attacks. In the physical protection field, it is important the maintain confidentiality of PPS related information, such as the alarm system layout, detailed maps of buildings, and guard schedules. In this abstract, we suggest establishing a methodology for an information security system. The first step in this methodology is to determine the information to protect and possible adversaries. Next, system designers should draw all possible paths to the information and arrange appropriate protection elements. Finally he/she should analyze and upgrade their information security system

  5. Design and operation of the quench protection system for the Fermilab tevatron

    International Nuclear Information System (INIS)

    Martin, P.S.

    1989-01-01

    The operation of a superconducting accelerator, in addition to cryogenic requirements, introduces a new complexity not present in a conventional accelerator. A method is required for protecting the magnets from possible overheating or overvoltage conditions in the event that some magnets quench, that is, are elevated in temperature so that they are no longer superconducting. The development of that system is the topic of this chapter. Any quench protection system has two very important ingredients. First, it must be designed with sufficient integrity to remain functional even under abnormal circumstances. The magnets must be protected during power failures, for example. Quenches involving a large number of components can also be hazardous because of the redistribution of voltages during the quench. Some of the system integrity can be achieved through redundancy. Frequent testing of critical elements of the system also assures the overall integrity. Second, the quench protection system must protect against damage from quenches regardless of their location or the excitation current at the time. It is not sufficient to protect just the magnet coils; either the leads between magnets must be fully stabilized or the quench protection system must protect them. The next section presents a brief discussion of the basic properties of superconductors and the phenomenon of quench propagation. 10 references, 13 figures

  6. Integrated Risk Information System (IRIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA?s Integrated Risk Information System (IRIS) is a compilation of electronic reports on specific substances found in the environment and their potential to cause...

  7. Development of the integrated core on-line monitoring and protection aid surveillance system

    International Nuclear Information System (INIS)

    Cho, Byung Oh; In, Wang Kee; Song, Jae Seung; Zee, Sung Quun

    1998-01-01

    The integrated Core On-line Monitoring and Protection Aid Surveillance System (COMPASS) is developed for the purpose of supporting the reactor operation, based on the three-dimensional nodal design code, MASTER. The heart of COMPASS is an adaptive nodal core simulator for the on-line calculation of three-dimensional assembly and pin power distributions which are used for the evaluation of the thermal margins and for the guide in operation. In this paper, the overall structures and the solution methods of COMPASS are described. The uncertainty of COMPASS for SMART core was also evaluated by comparing that of MASTER. The results showed that COMPASS uncertainty in power shape prediction is identical to that of the design code system, MASTER. The application of COMPASS to the analysis of peaking factor for SMART core resulted with about 4% gain in peaking factor margin when compared to COLSS

  8. EFFICIENCY INDICATORS INFORMATION MANAGEMENT IN INTEGRATED SECURITY SYSTEMS

    Directory of Open Access Journals (Sweden)

    N. S. Rodionova

    2014-01-01

    Full Text Available Summary. Introduction of information technology to improve the efficiency of security activity leads to the need to consider a number of negative factors associated with in consequence of the use of these technologies as a key element of modern security systems. One of the most notable factor is the exposure to information processes in protection systems security threats. This largely relates to integrated security systems (ISS is the system of protection with the highest level of informatization security functions. Significant damage to protected objects that they could potentially incur as a result of abnormal operation ISS, puts a very actual problem of assessing factors that reduce the efficiency of the ISS to justify the ways and methods to improve it. Because of the nature of threats and blocking distortion of information in the ISS of interest are: the volume undistorted ISF working environment, as a characteristic of data integrity; time access to information as a feature of its availability. This in turn leads to the need to use these parameters as the performance characteristics of information processes in the ISS - the completeness and timeliness of information processing. The article proposes performance indicators of information processes in integrated security systems in terms of optimal control procedures to protect information from unauthorized access. Set the considered parameters allows to conduct comprehensive security analysis of integrated security systems, and to provide recommendations to improve the management of information security procedures in them.

  9. Enhancement of observability and protection of smart power system

    Science.gov (United States)

    Siddique, Abdul Hasib

    It is important for a modern power grid to be smarter in order to provide reliable and sustainable supply of electricity. Traditional way of receiving data from the wired system is a very old and outdated technology. For a quicker and better response from the electric system, it is important to look at wireless systems as a feasible option. In order to enhance the observability and protection it is important to integrate wireless technology with the modern power system. In this thesis, wireless network based architecture for wide area monitoring and an alternate method for performing current measurement for protection of generators and motors, has been adopted. There are basically two part of this project. First part deals with the wide area monitoring of the power system and the second part focuses more on application of wireless technology from the protection point of view. A number of wireless method have been adopted in both the part, these includes Zigbee, analog transmission (Both AM and FM) and digital transmission. The main aim of our project was to propose a cost effective wide area monitoring and protection method which will enhance the observability and stability of power grid. A new concept of wireless integration in the power protection system has been implemented in this thesis work.

  10. Integration of radiation protection in safety management: sharing best practices between radiation protection and other safety areas

    International Nuclear Information System (INIS)

    Kockerols, Pierre; Fessler, Andreas

    2008-01-01

    Full text: The Institute for Reference Materials and Measurements (IRMM) located in Geel is one of the seven institutes of the Joint Research Centre of the European Commission (EC, DG JRC). The institute was founded in 1960 as a nuclear research centre, but has gradually shifted its activities to also include 'non-nuclear' domains, mainly in the areas of food safety and environmental surveillance. As the activities on the IRMM site are currently quite diversified, they necessitate the operation of nuclear controlled areas, accelerators, as well as bio safety restricted areas and chemical laboratories. Therefore, the care for occupational health and safety and for environmental protection has to take into consideration various types of hazards and threats. Recently an integrated management system according to ISO-9001, ISO-14001 and OHSAS-18001 was implemented. The integrated system combines 'vertically' quality, occupational health and safety and environmental issues and covers 'horizontally' the nuclear, biological and chemical fields. The paper outlines how the radiation protection can be included in an overall health, safety and environmental management system. It will give various practical examples where synergies can be applied: 1-) the overall policy; 2-) The assessment and ranking of all risks and the identification, in a combined way, of the appropriate prevention measures; 3-) The planning and review of related actions; 4-) The monitoring, auditing and registration of anomalies and incidents and the definition of corrective actions; 5-) The training of personnel based on lessons learned from past experiences; 6-) The organisation of an internal emergency plan dealing with nuclear and non-nuclear hazards. Based on these examples, the benefits of having an integrated approach are commented. In addition, the paper will illustrate how the recent ICRP fundamental recommendations and more particularly some of the principles of radiation protection such as

  11. Trip setpoint analysis for the reactor protection system of an advanced integral reactor

    International Nuclear Information System (INIS)

    Yang, Soo Hyung; Kim, Soo Hyung; Chung, Young Jong; Zee, Sung Quun

    2007-01-01

    The trip setpoints for the reactor protection system of a 65-MWt advanced integral reactor have been analyzed through sensitivity evaluations by using the Transients and Setpoint Simulation/System-integrated Modular Reactor code. In the analysis, an inadvertent control rod withdrawal event has been considered as an initiating event because this event results in the worst consequences from the viewpoint of the minimum critical heat flux ratio and its consequences are considerably affected by the trip setpoints. Sensitivity evaluations have been performed by changing the trip setpoints for the ceiling of a variable overpower trip (VOPT) function and the pressure of a high pressurizer pressure trip function. Analysis results show that a VOPT function is an effective means to satisfy the acceptance criteria as the control rod rapidly withdraws: on the other hand, a high pressurizer pressure trip function is an essential measure to preserve the safety margin in the case of a slow withdrawal of the control rod because a reactor trip by a VOPT function does not occur in this case. It is also shown that the adoptions of 122.2% of the rated core power and 16.25 MPa as the trip setpoint for the ceiling of a VOPT function and the pressure of a high pressurizer pressure trip function are good selections to satisfy the acceptance criteria

  12. Short circuit analysis of distribution system with integration of DG

    DEFF Research Database (Denmark)

    Su, Chi; Liu, Zhou; Chen, Zhe

    2014-01-01

    and as a result bring challenges to the network protection system. This problem has been frequently discussed in the literature, but mostly considering only the balanced fault situation. This paper presents an investigation on the influence of full converter based wind turbine (WT) integration on fault currents......Integration of distributed generation (DG) such as wind turbines into distribution system is increasing all around the world, because of the flexible and environmentally friendly characteristics. However, DG integration may change the pattern of the fault currents in the distribution system...... during both balanced and unbalanced faults. Major factors such as external grid short circuit power capacity, WT integration location, connection type of WT integration transformer are taken into account. In turn, the challenges brought to the protection system in the distribution network are presented...

  13. Protecting Digital Evidence Integrity by Using Smart Cards

    Science.gov (United States)

    Saleem, Shahzad; Popov, Oliver

    RFC 3227 provides general guidelines for digital evidence collection and archiving, while the International Organization on Computer Evidence offers guidelines for best practice in the digital forensic examination. In the light of these guidelines we will analyze integrity protection mechanism provided by EnCase and FTK which is mainly based on Message Digest Codes (MDCs). MDCs for integrity protection are not tamper proof, hence they can be forged. With the proposed model for protecting digital evidence integrity by using smart cards (PIDESC) that establishes a secure platform for digitally signing the MDC (in general for a whole range of cryptographic services) in combination with Public Key Cryptography (PKC), one can show that this weakness might be overcome.

  14. Reactor protection systems of 500 MWe PHWRs

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, G; Kelkar, M G; Apte, Ravindra [C and I Group, Nuclear Power Corporation, Mumbai (India)

    1997-03-01

    The 500 MWe PHWR has two totally independent, diverse, fast acting shutdown system called Shutdown System 1 (SDS 1) and Shutdown System 2 (SDS 2). The trip generation circuitry of SDS 1 and SDS 2 are known as Reactor Protection System 1 (RPS 1) and Reactor Protection System 2 (RPS 2) respectively. Some of the features specific to 500 MWe reactors are Core Over Power Protection System (COPPS) based upon in core Self Powered Neutron Detector (SPND) signals, use of local two out of three coincidence logic and adoption of overlap testing for RPS 2, use of Fine Impulse Testing (FIT) in RPS 2, testing of the final control elements namely electro-magnetic clutch of individual Shutoff Rods (SRs) of SDS 1 and all the fast acting valves of SDS 2, etc. The two shutdown systems have totally separate sets of sensors and associated signal processing circuitry as well as physical arrangements. A separate computerised test and monitoring unit is used for each of the two shutdown systems. Use of Programmable Digital Comparator (PDC) unit exclusively for reactor protection systems, has been adopted. The capability of PDC unit is enhanced and communication links are provided for its integration in over all system. The paper describes the design features of reactor protection systems. (author). 3 refs., 7 figs., 3 tabs.

  15. Circuit protection of ehv power systems from 150 to 765 kV

    Energy Technology Data Exchange (ETDEWEB)

    Geise, F; Jaeger, J

    1965-11-01

    Short tripping times required for all faults in ehv transmission systems are obtained by means of differential and comparative protection arrangements. It is essential that protection and communication systems be closely integrated and that special current transformers with linearized cores supply protective devices with correct measured values. By arranging filters between transformer and directional relay, it is possible to use capacitive voltage transformers for high speed protection. A description of power system with backup protection devices is presented.

  16. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration

  17. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-12-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration.

  18. Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

    Science.gov (United States)

    Milos, Frank S.; Karunaratne, K.; Arnold, Jim (Technical Monitor)

    2002-01-01

    Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

  19. Recent advances in reactor protection and control system technology

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    After a first-generation digital integrated protection system has been installed on all 1300 MWe PWR units in France, a new digital protection system was developed for the 1450 MWe units, using local area networks, fiber optics, Motorola 68000 microprocessors, and a modular design allowing for the design of any system on the basis of around 50 types of standard cards. In 1993, an upgrading program for this equipment was launched in order to reduce costs, in particular software development costs, further improve hardware modularity and facilitate integration and connection to existing equipment. The basic principles of the units are described together with the implementation of computer-aided software engineering (CASE) tools, interfaces with hard-wired equipment, and multiplexed connections. The nuclear instrumentation systems at the Fessenheim and Bugey plants have been renovated with these equipment

  20. Operational test report - Project W-320 cathodic protection systems

    International Nuclear Information System (INIS)

    Bowman, T.J.

    1998-01-01

    Washington Administrative Code (WAC) 173-303-640 specifies that corrosion protection must be designed into tank systems that treat or store dangerous wastes. Project W-320, Waste Retrieval Sluicing System (WRSS), utilizes underground encased waste transfer piping between tanks 241-C-106 and 241-AY-102. Corrosion protection is afforded to the encasements of the WRSS waste transfer piping through the application of earthen ionic currents onto the surface of the piping encasements. Cathodic protection is used in conjunction with the protective coatings that are applied upon the WRSS encasement piping. WRSS installed two new two rectifier systems (46 and 47) and modified one rectifier system (31). WAC 173-303-640 specifies that the proper operation of cathodic protection systems must be confirmed within six months after initial installation. The WRSS cathodic protection systems were energized to begin continuous operation on 5/5/98. Sixteen days after the initial steady-state start-up of the WRSS rectifier systems, the operational testing was accomplished with procedure OTP-320-006 Rev/Mod A-0. This operational test report documents the OTP-320-006 results and documents the results of configuration testing of integrated piping and rectifier systems associated with the W-320 cathodic protection systems

  1. Validation of reactor core protection system

    International Nuclear Information System (INIS)

    Lee, Sang-Hoon; Bae, Jong-Sik; Baeg, Seung-Yeob; Cho, Chang-Ho; Kim, Chang-Ho; Kim, Sung-Ho; Kim, Hang-Bae; In, Wang-Kee; Park, Young-Ho

    2008-01-01

    Reactor COre Protection System (RCOPS), an advanced core protection calculator system, is a digitized one which provides core protection function based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels adapted a two-out-of-four trip logic. System configuration, hardware platform and an improved algorithm of the newly designed core protection calculator system are described in this paper. One channel of RCOPS was implemented as a single channel facility for this R and D project where we performed final integration software testing. To implement custom function blocks, pSET is used. Software test is performed by two methods. The first method is a 'Software Module Test' and the second method is a 'Software Unit Test'. New features include improvement of core thermal margin through a revised on-line DNBR algorithm, resolution of the latching problem of control element assembly signal and addition of the pre-trip alarm generation. The change of the on-line DNBR calculation algorithm is considered to improve the DNBR net margin by 2.5%-3.3%. (author)

  2. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  3. Mechanisms of protection of information in computer networks and systems

    Directory of Open Access Journals (Sweden)

    Sergey Petrovich Evseev

    2011-10-01

    Full Text Available Protocols of information protection in computer networks and systems are investigated. The basic types of threats of infringement of the protection arising from the use of computer networks are classified. The basic mechanisms, services and variants of realization of cryptosystems for maintaining authentication, integrity and confidentiality of transmitted information are examined. Their advantages and drawbacks are described. Perspective directions of development of cryptographic transformations for the maintenance of information protection in computer networks and systems are defined and analyzed.

  4. Legal Protection on IP Cores for System-on-Chip Designs

    Science.gov (United States)

    Kinoshita, Takahiko

    The current semiconductor industry has shifted from vertical integrated model to horizontal specialization model in term of integrated circuit manufacturing. In this circumstance, IP cores as solutions for System-on-Chip (SoC) have become increasingly important for semiconductor business. This paper examines to what extent IP cores of SoC effectively can be protected by current intellectual property system including integrated circuit layout design law, patent law, design law, copyright law and unfair competition prevention act.

  5. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  6. Experience of developing and introduction of the integrated systems for accounting, control and physical protection of nuclear materials under conditions of continuously operating production

    International Nuclear Information System (INIS)

    Filatov, O.N.; Rogachev, V.E.

    2003-01-01

    The improvements of the integrated systems for accounting, control and physical protection (ACPP) of nuclear materials under conditions practically continuous production cycle are described. As a result of development and introduction of the improved means and technologies the developed systems realized successfully the requirements of reliable ACPP of nuclear materials [ru

  7. Digital integrated protection system: Quantitative methods for dependability evaluation

    International Nuclear Information System (INIS)

    Krotoff, H.; Benski, C.

    1986-01-01

    The inclusion of programmed digital techniques in the SPIN system provides the used with the capability of performing sophisticated processing operations. However, it causes the quantitative evaluation of the overall failure probabilities to become somewhat more intricate by reason that: A single component may be involved in several functions; Self-tests may readily be incorporated for the purpose of monitoring the dependable operation of the equipment at all times. This paper describes the methods as implemented by MERLIN GERIN for the purpose of evaluating: The probabilities for the protective actions not to be initiated (dangerous failures); The probabilities for such protective actions to be initiated accidentally. Although the communication is focused on the programmed portion of the SPIN (UAIP) it will also deal with the evaluation performed within the scope of study works that do not exclusively cover the UAIPs

  8. An integrated and open source GIS environmental management system for a protected area in the south of Portugal

    Science.gov (United States)

    Teodoro, A.; Duarte, L.; Sillero, N.; Gonçalves, J. A.; Fonte, J.; Gonçalves-Seco, L.; Pinheiro da Luz, L. M.; dos Santos Beja, N. M. R.

    2015-10-01

    Herdade da Contenda (HC), located in Moura municipality, Beja district (Alentejo province) in the south of Portugal (southwestern Iberia Peninsula), is a national hunting area with 5270ha. The development of an integrated system that aims to make the management of the natural and cultural heritage resources will be very useful for an effective management of this area. This integrated system should include the physical characterization of the territory, natural conservation, land use and land management themes, as well the cultural heritage resources. This paper presents a new tool for an integrated environmental management system of the HC, which aims to produce maps under a GIS open source environment (QGIS). The application is composed by a single button which opens a window. The window is composed by twelve menus (File, DRASTIC, Forest Fire Risk, Revised Universal Soil Loss Equation (RUSLE), Bioclimatic Index, Cultural Heritage, Fauna and Flora, Ortofoto, Normalizes Difference Vegetation Index (NDVI), Digital Elevation Model (DEM), Land Use Land Cover Cover (LULC) and Help. Several inputs are requires to generate these maps, e.g. DEM, geologic information, soil map, hydraulic conductivity information, LULC map, vulnerability and economic information, NDVI. Six buttons were added to the toolbar which allows to manipulate the information in the map canvas: Zoom in, Zoom out, Pan, Print/Layout and Clear. This integrated and open source GIS environment management system was developed for the HC area, but could be easily adapted to other natural or protected area. Despite the lack of data, the methodology presented fulfills the objectives.

  9. Performance of the Protection System for Superconducting Circuits during LHC Operation

    OpenAIRE

    Denz, R; Charifoulline, Z; Dahlerup-Petersen, K; Schmidt, R; Siemko, A; Steckert, J

    2011-01-01

    The protection system for superconducting magnets and bus-bars is an essential part of the LHC machine protection and ensures the integrity of substantial elements of the accelerator. Due to the large amount of hardwired and software interlock channels the dependability of the system is a critical parameter for the successful operation of the LHC.

  10. Progress on Protection Strategies to Mitigate the Impact of Renewable Distributed Generation on Distribution Systems

    Directory of Open Access Journals (Sweden)

    Mohamad Norshahrani

    2017-11-01

    Full Text Available The benefits of distributed generation (DG based on renewable energy sources leads to its high integration in the distribution network (DN. Despite its well-known benefits, mainly in improving the distribution system reliability and security, there are challenges encountered from a protection system perspective. Traditionally, the design and operation of the protection system are based on a unidirectional power flow in the distribution network. However, the integration of distributed generation causes multidirectional power flows in the system. Therefore, the existing protection systems require some improvement or modification to address this new feature. Various protection strategies for distribution system have been proposed so that the benefits of distributed generation can be fully utilized. This paper reviews the current progress in protection strategies to mitigate the impact of distributed generation in the distribution network. In general, the reviewed strategies in this paper are divided into: (1 conventional protection systems and (2 modifications of the protection systems. A comparative study is presented in terms of the respective benefits, shortcomings and implementation cost. Future directions for research in this area are also presented.

  11. Nature protection in Greece: an appraisal of the factors shaping integrative conservation and policy effectiveness

    International Nuclear Information System (INIS)

    Papageorgiou, Kostas; Vogiatzakis, Ioannis N.

    2006-01-01

    The proliferation of designated areas following the implementation of Natura 2000 in Greece has initiated changes in the protected area design and conservation policy making aiming at delivering action for biodiversity and integrative planning on a wider landscape. Following the sustainability concept, an integrative approach cannot realistically take place simply by extending the protected area and designations. The paper addresses public involvement and inter-sectoral coordination as major procedural elements of integrative management and evaluates the nature and strength of their negative or positive influences on the fulfillment of an integrative vision of nature conservation. A review of the history of protected areas and administration developments in Greece provide useful input in the research. The analysis has shown that the selected network of Natura 2000 sites has been superimposed upon the existing system and resulted in duplication of administrative effort and related legislation. As a result the overall picture of protected areas in the country appears complex, confusing and fragmented. Major failures to integrated conservation perspective can be traced to structural causes rooted in politico-economic power structures of mainstream policy and in a rather limited political commitment to conservation. It is concluded that greater realisation of integrated conservation in Greece necessitates policy reforms related mainly to sectoral legal frameworks to promote environmentalism as well as an increased effort by the managing authorities to facilitate a broader framework of public dialogue and give local communities incentives to sustainably benefit from protected areas

  12. Machine protection systems

    CERN Document Server

    Macpherson, A L

    2010-01-01

    A summary of the Machine Protection System of the LHC is given, with particular attention given to the outstanding issues to be addressed, rather than the successes of the machine protection system from the 2009 run. In particular, the issues of Safe Machine Parameter system, collimation and beam cleaning, the beam dump system and abort gap cleaning, injection and dump protection, and the overall machine protection program for the upcoming run are summarised.

  13. Integrating Photovoltaic Systems in Power System: Power Quality Impacts and Optimal Planning Challenges

    Directory of Open Access Journals (Sweden)

    Aida Fazliana Abdul Kadir

    2014-01-01

    Full Text Available This paper is an overview of some of the main issues in photovoltaic based distributed generation (PVDG. A discussion of the harmonic distortion produced by PVDG units is presented. The maximum permissible penetration level of PVDG in distribution system is also considered. The general procedures of optimal planning for PVDG placement and sizing are also explained in this paper. The result of this review shows that there are different challenges for integrating PVDG in the power systems. One of these challenges is integrated system reliability whereas the amount of power produced by renewable energy source is consistent. Thus, the high penetration of PVDG into grid can decrease the reliability of the power system network. On the other hand, power quality is considered one of the challenges of PVDG whereas the high penetration of PVDGs can lead to more harmonic propagation into the power system network. In addition to that, voltage fluctuation of the integrated PVDG and reverse power flow are two important challenges to this technology. Finally, protection of power system with integrated PVDG is one of the most critical challenges to this technology as the current protection schemes are designed for unidirectional not bidirectional power flow pattern.

  14. Power Systems Integration Laboratory | Energy Systems Integration Facility

    Science.gov (United States)

    | NREL Power Systems Integration Laboratory Power Systems Integration Laboratory Research in the Energy System Integration Facility's Power Systems Integration Laboratory focuses on the microgrid applications. Photo of engineers testing an inverter in the Power Systems Integration Laboratory

  15. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2005-11-01

    One of the main challenges facing radiological protection experts is how to integrate radiological protection within modern concepts of and approaches to risk governance. It is within this context that the International Commission on Radiological Protection (ICRP) decided to develop new general recommendations to replace its Publication 60 recommendations of 1990. In the process of developing these new recommendations, the views of the ICRP have evolved significantly, largely due to stakeholder involvement that has been actively solicited by the ICRP. In this regard, it was upheld during the First Asian Regional Conference organised by the NEA in October 2002 that the implementation of the new system must allow for regional, societal and cultural differences. In order to ensure appropriate consideration of these differences, the NEA organised the Second Asian Regional Conference on the Evolution of the System of Radiological Protection. Held in Tokyo on 28-29 July 2004, the conference included presentations by the ICRP Chair as well as by radiological experts from Australia, China, Japan and Korea. Within their specific cultural and socio-political milieu, Asia-Pacific and western ways of thought on how to improve the current system of radiological protection were presented and discussed. These ways of thinking, along with a summary of the conference results, are described in these proceedings. (author)

  16. A Trusted Autonomic Architecture to Safeguard Cyber-Physical Control Leaf Nodes and Protect Process Integrity

    OpenAIRE

    Chiluvuri, Nayana Teja

    2015-01-01

    Cyber-physical systems are networked through IT infrastructure and susceptible to malware. Threats targeting process control are much more safety-critical than traditional computing systems since they jeopardize the integrity of physical infrastructure. Existing defence mechanisms address security at the network nodes but do not protect the physical infrastructure if network integrity is compromised. An interface guardian architecture is implemented on cyber-physical control leaf nodes to mai...

  17. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  18. River Protection Project information systems assessment

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    1999-01-01

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report

  19. Illustration of distributed generation effects on protection system coordination

    Science.gov (United States)

    Alawami, Hussain Adnan

    Environmental concerns, market forces, and emergence of new technologies have recently resulted in restructuring electric utility from vertically integrated networks to competitive deregulated entities. Distributed generation (DG) is playing a major role in such deregulated markets. When they are installed in small amounts and small sizes, their impacts on the system may be negligible. When their penetration levels increase as well as their sizes, however, they may start affecting the system performance from more than one aspect. Power system protection needs to be re-assessed after the emergence of DG. This thesis attempts to illustrate the impact of DG on the power system protection coordination. It will study the operation of the impedance relays, fuses, reclosers and overcurrent relays when a DG is added to the distribution network. Different DG sizes, distances from the network and locations within the distribution system will be considered. Power system protection coordination is very sensitive to the DG size where it is not for the DG distance. DG location has direct impact on the operation of the protective devices especially when it is inserted in the middle point of the distribution system. Key Words, Distributed Generation, Impedance relay, fuses, reclosers, overcurrent relays, power system protection coordination.

  20. INTEGRATED SYSTEMS IN PLANT PROTECTION MANAGEMENT: FIRE BLIGHT OF ROSACEOUS PLANTS (Erwinia amylovora (Burrill - Winslow IN AN APPLE ORCHARD IN SIBIU COUNTY

    Directory of Open Access Journals (Sweden)

    Maria TĂNASE

    2013-12-01

    Full Text Available Integrated protection represents a modern approach, denoting a protection strategy of agro-ecosystems; and it represents a complex system employing all appropriate methods in a manner as consistent and smooth as possible, in order to maintain the biocenotic balance of agrosystems and to keep pathogens at a level at which they do not cause economic damage (so-called level of eco-efficiency. A biocenotic approach to issues of agrosystem protection against disease attack requires an acknowledgement of all aspects regarding the evolution of pests in time and space, so as to be able to intervene at the right time with all possible means. And such protection measures are not supposed to restrain existing tendencies in the agrosystem. Therefore, this implies the awareness that any applied protection measures do not affect solely a certain pathogen, but the entire plant and animal community, as well as the soil and water.

  1. Adaptive Overcurrent Protection for Microgrids in Extensive Distribution Systems

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Jia, Chenxi

    2016-01-01

    Microgrid is regarded as a new form to integrate the increasing penetration of distributed generation units (DGs) in the extensive distribution systems. This paper proposes an adaptive overcurrent protection strategy for a microgrid network. The protection coordination of the overcurrent relays...... measurements in another neural network model. Reconfigurations can be performed to modify the settings of the on-field relays to enhance the reliable operation for the different operational situations. The test results show that the adaptive overcurrent protection scheme with the assistance of estimation model...... can modify the protective settings for the new operation state accurately and intelligently....

  2. Setting value optimization method in integration for relay protection based on improved quantum particle swarm optimization algorithm

    Science.gov (United States)

    Yang, Guo Sheng; Wang, Xiao Yang; Li, Xue Dong

    2018-03-01

    With the establishment of the integrated model of relay protection and the scale of the power system expanding, the global setting and optimization of relay protection is an extremely difficult task. This paper presents a kind of application in relay protection of global optimization improved particle swarm optimization algorithm and the inverse time current protection as an example, selecting reliability of the relay protection, selectivity, quick action and flexibility as the four requires to establish the optimization targets, and optimizing protection setting values of the whole system. Finally, in the case of actual power system, the optimized setting value results of the proposed method in this paper are compared with the particle swarm algorithm. The results show that the improved quantum particle swarm optimization algorithm has strong search ability, good robustness, and it is suitable for optimizing setting value in the relay protection of the whole power system.

  3. A Westinghouse designed distributed mircroprocessor based protection and control system

    International Nuclear Information System (INIS)

    Bruno, J.; Reid, J.B.

    1980-01-01

    For approximately five years, Westinghouse has been involved in the design and licensing of a distributed microprocessor based system for the protection and control of a pressurized water reactor nuclear steam supply system. A 'top-down' design methodology was used, in which the system global performance objectives were specified, followed by increasingly more detailed design specifications which ultimately decomposed the system into its basic hardware and software elements. The design process and design decisions were influenced by the recognition that the final product would have to be verified to ensure its capability to perform the safety-related functions of a class 1E protection system. The verification process mirrored the design process except that it was 'bottom-up' and thus started with the basic elements and worked upwards through the system in increasingly complex blocks. A number of areas which are of interest in a distributed system are disucssed, with emphasis on two systems. The first, the Integrated Protection System is primarily responsible for processing signals from field mounted sensors to provide for reactor trips and the initiation of the Engineered Safety Features. The Integrated Control System, which is organized in a parallel manner, processes other sensor signals and generates the necessary analog and on-off signals to maintain the plant parameters within specified limits. Points covered include system structure, systems partitioning strategies, communications techniques, software design concepts, reliability and maintainability, commercial component availability, interference susceptibility, licensing issues, and applicability. (LL)

  4. Specific features of using programmed hardware in emergency protection systems of NPP

    International Nuclear Information System (INIS)

    Konoplev, N.P.; Pogorelov, I.V.; Kirsanov, A.V.

    2005-01-01

    The specific features of using the microprocessor-based technical means and programmed logic integrated circuits (PLIC) in WWER reactor protection systems are considered. The basic causes of occurring the failures in programmed technical means are analyzed. The features of using PLIC in reactor protection systems are discussed. The methods permitting to decrease the probability occurring the common mode failure of programmed technical means are proposed. It is concluded that at creating of reactor protection systems with the use of microprocessors and PLIC it is necessary to apply the principle of the functional diversity [ru

  5. Integrating the radioactive waste management system into other management systems

    International Nuclear Information System (INIS)

    Silva, Ana Cristina Lourenco da; Nunes Neto, Carlos Antonio

    2007-01-01

    Radioactive waste management is to be included in the Integrated Management System (IMS) which pursues the continuous improvement of the company's quality, occupational safety and health, and environment protection processes. Radioactive waste management is based on the following aspects: optimization of human and material resources for execution of tasks, including the provision of a radiation protection supervisor to watch over the management of radioactive waste; improved documentation (management plan and procedures); optimization of operational levels for waste classification and release; maintenance of generation records and history through a database that facilitates traceability of information; implementation of radioactive waste segregation at source (source identification, monitoring and decontamination) activities intended to reduce the amount of radioactive waste; licensing of initial storage site for radioactive waste control and storage; employee awareness training on radioactive waste generation; identification and evaluation of emergency situations and response planning; implementation of preventive maintenance program for safety related items; development and application of new, advanced treatment methodologies or systems. These aspects are inherent in the concepts underlying quality management (establishment of administrative controls and performance indicators), environment protection (establishment of operational levels and controls for release), occupational health and safety (establishment of operational controls for exposure in emergency and routine situations and compliance with strict legal requirements and standards). It is noted that optimizing the addressed aspects of a radioactive waste management system further enhances the efficiency of the Integrated Management System for Quality, Environment, and Occupational Safety and Health. (author)

  6. 45 CFR 61.1 - The Healthcare Integrity and Protection Data Bank.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false The Healthcare Integrity and Protection Data Bank. 61.1 Section 61.1 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION HEALTHCARE INTEGRITY AND PROTECTION DATA BANK FOR FINAL ADVERSE INFORMATION ON HEALTH CARE PROVIDERS...

  7. Integrated crop protection and environment exposure to pesticides: methods to reduce use and impact of pesticides in arable farming

    NARCIS (Netherlands)

    Wijnands, F.G.

    1997-01-01

    Prototypes of Integrated Farming Systems for arable farming are being developed in the Netherlands based on a coherent methodology elaborated in an European Union concerted action. The role of crop protection in Integrated systems is, additional to all other methods, to efficiently control the

  8. INTEGRATION OF ENVIRONMENTAL MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Tomescu Ada Mirela

    2012-07-01

    Full Text Available The relevance of management as significant factor of business activity can be established on various management systems. These will help to obtain, organise, administrate, evaluate and control particulars: information, quality, environmental protection, health and safety, various resources (time, human, finance, inventory etc. The complexity of nowadays days development, forced us to think ‘integrated’. Sustainable development principles require that environment management policies and practices are not good in themselves but also integrate with all other environmental objectives, and with social and economic development objectives. The principles of sustainable development involve that environment management policies and practices. These are not sound in them-self but also integrate with all other environmental objectives, and with social and economic development objectives. Those objectives were realized, and followed by development of strategies to effects the objective of sustainable development. Environmental management should embrace recent change in the area of environmental protection, and suit the recently regulations of the field -entire legal and economic, as well as perform management systems to meet the requirements of the contemporary model for economic development. These changes are trailed by abandon the conventional approach of environmental protection and it is replaced by sustainable development (SD. The keys and the aims of Cleaner Productions (CP are presented being implemented in various companies as a non-formalised environmental management system (EMS. This concept is suggested here as a proper model for practice where possible environmental harmful technologies are used -e.g. Rosia Montana. Showing the features and the power of CP this paper is a signal oriented to involve the awareness of policy-makers and top management of diverse Romanian companies. Many companies in European countries are developing

  9. Novel Directional Protection Scheme for the FREEDM Smart Grid System

    Science.gov (United States)

    Sharma, Nitish

    This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. The addition of distributed generation and power electronic based solid state transformer adds to the complexity of the protection. The FREEDM loop system has a fault current limiter and in addition, the Solid State Transformer (SST) limits the fault current at 2.0 per unit. Former students at ASU have developed the protection scheme using fiber-optic cable. However, during the NSF-FREEDM site visit, the National Science Foundation (NSF) team regarded the system incompatible for the long distances. Hence, a new protection scheme with a wireless scheme is presented in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The trip signal generated by the pilot protection system is used to trigger the FID (fault isolation device) which is an electronic circuit breaker operation (switched off/opening the FIDs). The trip signal must be received and accepted by the SST, and it must block the SST operation immediately. A comprehensive protection system for the large scale meshed distribution system has been developed in PSCAD with the ability to quickly detect the faults. The validation of the protection system is performed by building a hardware model using commercial relays at the ASU power laboratory.

  10. Integrated seismic design of structure and control systems

    CERN Document Server

    Castaldo, Paolo

    2014-01-01

    The structural optimization procedure presented in this book makes it possible to achieve seismic protection through integrated structural/control system design. In particular, it is explained how slender structural systems with a high seismic performance can be achieved through inclusion of viscous and viscoelastic dampers as an integral part of the system. Readers are provided with essential introductory information on passive structural control and passive energy dissipation systems. Dynamic analyses of both single and multiple degree of freedom systems are performed in order to verify the achievement of pre-assigned performance targets, and it is explained how the optimal integrated design methodology, also relevant to retrofitting of existing buildings, should be applied. The book illustrates how structural control research is opening up new possibilities in structural forms and configurations without compromising structural performance.

  11. An integrated approach towards future ballistic neck protection materials selection.

    Science.gov (United States)

    Breeze, John; Helliker, Mark; Carr, Debra J

    2013-05-01

    Ballistic protection for the neck has historically taken the form of collars attached to the ballistic vest (removable or fixed), but other approaches, including the development of prototypes incorporating ballistic material into the collar of an under body armour shirt, are now being investigated. Current neck collars incorporate the same ballistic protective fabrics as the soft armour of the remaining vest, reflecting how ballistic protective performance alone has historically been perceived as the most important property for neck protection. However, the neck has fundamental differences from the thorax in terms of anatomical vulnerability, flexibility and equipment integration, necessitating a separate solution from the thorax in terms of optimal materials selection. An integrated approach towards the selection of the most appropriate combination of materials to be used for each of the two potential designs of future neck protection has been developed. This approach requires evaluation of the properties of each potential material in addition to ballistic performance alone, including flexibility, mass, wear resistance and thermal burden. The aim of this article is to provide readers with an overview of this integrated approach towards ballistic materials selection and an update of its current progress in the development of future ballistic neck protection.

  12. SUBSURFACE REPOSITORY INTEGRATED CONTROL SYSTEM DESIGN

    International Nuclear Information System (INIS)

    C.J. Fernado

    1998-01-01

    The purpose of this document is to develop preliminary high-level functional and physical control system architectures for the proposed subsurface repository at Yucca Mountain. This document outlines overall control system concepts that encompass and integrate the many diverse systems being considered for use within the subsurface repository. This document presents integrated design concepts for monitoring and controlling the diverse set of subsurface operations. The subsurface repository design will be composed of a series of diverse systems that will be integrated to accomplish a set of overall functions and objectives. The subsurface repository contains several Instrumentation and Control (I andC) related systems including: waste emplacement systems, ventilation systems, communication systems, radiation monitoring systems, rail transportation systems, ground control monitoring systems, utility monitoring systems (electrical, lighting, water, compressed air, etc.), fire detection and protection systems, retrieval systems, and performance confirmation systems. Each of these systems involve some level of I andC and will typically be integrated over a data communication network. The subsurface I andC systems will also integrate with multiple surface-based site-wide systems such as emergency response, health physics, security and safeguards, communications, utilities and others. The scope and primary objectives of this analysis are to: (1) Identify preliminary system level functions and interface needs (Presented in the functional diagrams in Section 7.2). (2) Examine the overall system complexity and determine how and on what levels these control systems will be controlled and integrated (Presented in Section 7.2). (3) Develop a preliminary subsurface facility-wide design for an overall control system architecture, and depict this design by a series of control system functional block diagrams (Presented in Section 7.2). (4) Develop a series of physical architectures

  13. SUBSURFACE REPOSITORY INTEGRATED CONTROL SYSTEM DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Fernado

    1998-09-17

    The purpose of this document is to develop preliminary high-level functional and physical control system architectures for the proposed subsurface repository at Yucca Mountain. This document outlines overall control system concepts that encompass and integrate the many diverse systems being considered for use within the subsurface repository. This document presents integrated design concepts for monitoring and controlling the diverse set of subsurface operations. The subsurface repository design will be composed of a series of diverse systems that will be integrated to accomplish a set of overall functions and objectives. The subsurface repository contains several Instrumentation and Control (I&C) related systems including: waste emplacement systems, ventilation systems, communication systems, radiation monitoring systems, rail transportation systems, ground control monitoring systems, utility monitoring systems (electrical, lighting, water, compressed air, etc.), fire detection and protection systems, retrieval systems, and performance confirmation systems. Each of these systems involve some level of I&C and will typically be integrated over a data communication network. The subsurface I&C systems will also integrate with multiple surface-based site-wide systems such as emergency response, health physics, security and safeguards, communications, utilities and others. The scope and primary objectives of this analysis are to: (1) Identify preliminary system level functions and interface needs (Presented in the functional diagrams in Section 7.2). (2) Examine the overall system complexity and determine how and on what levels these control systems will be controlled and integrated (Presented in Section 7.2). (3) Develop a preliminary subsurface facility-wide design for an overall control system architecture, and depict this design by a series of control system functional block diagrams (Presented in Section 7.2). (4) Develop a series of physical architectures that

  14. River Protection Project information systems assessment

    Energy Technology Data Exchange (ETDEWEB)

    JOHNSON, A.L.

    1999-07-28

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report.

  15. Adaptive Protection Scheme for a Distribution System Considering Grid-Connected and Islanded Modes of Operation

    Directory of Open Access Journals (Sweden)

    Yavuz Ates

    2016-05-01

    Full Text Available The renewable energy-based distributed generation (DG implementation in power systems has been an active research area during the last few decades due to several environmental, economic and political factors. Although the integration of DG offers many advantages, several concerns, including protection schemes in systems with the possibility of bi-directional power flow, are raised. Thus, new protection schemes are strongly required in power systems with a significant presence of DG. In this study, an adaptive protection strategy for a distribution system with DG integration is proposed. The proposed strategy considers both grid-connected and islanded operating modes, while the adaptive operation of the protection is dynamically realized considering the availability of DG power production (related to faults or meteorological conditions in each time step. Besides, the modular structure and fast response of the proposed strategy is validated via simulations conducted on the IEEE 13-node test system.

  16. An integrated model for reliability estimation of digital nuclear protection system based on fault tree and software control flow methodologies

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Seong, Poong Hyun

    2000-01-01

    In the nuclear industry, the difficulty of proving the reliabilities of digital systems prohibits the widespread use of digital systems in various nuclear application such as plant protection system. Even though there exist a few models which are used to estimate the reliabilities of digital systems, we develop a new integrated model which is more realistic than the existing models. We divide the process of estimating the reliability of a digital system into two phases, a high-level phase and a low-level phase, and the boundary of two phases is the reliabilities of subsystems. We apply software control flow method to the low-level phase and fault tree analysis to the high-level phase. The application of the model to Dynamic Safety System(DDS) shows that the estimated reliability of the system is quite reasonable and realistic

  17. An integrated model for reliability estimation of digital nuclear protection system based on fault tree and software control flow methodologies

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Seong, Poong Hyun

    2000-01-01

    In nuclear industry, the difficulty of proving the reliabilities of digital systems prohibits the widespread use of digital systems in various nuclear application such as plant protection system. Even though there exist a few models which are used to estimate the reliabilities of digital systems, we develop a new integrated model which is more realistic than the existing models. We divide the process of estimating the reliability of a digital system into two phases, a high-level phase and a low-level phase, and the boundary of two phases is the reliabilities of subsystems. We apply software control flow method to the low-level phase and fault tree analysis to the high-level phase. The application of the model of dynamic safety system (DSS) shows that the estimated reliability of the system is quite reasonable and realistic. (author)

  18. An FPGA-Based Quench Detection and Protection System for Superconducting Accelerator Magnets

    CERN Document Server

    Carcagno, Ruben H; Lamm, Michael J; Makulski, Andrzej; Nehring, Roger; Orris, Darryl; Pishchalnikov, Yu M; Tartaglia, M

    2005-01-01

    A new quench detection and protection system for superconducting accelerator magnets was developed at the Fermilab's Magnet Test Facility (MTF). This system is based on a Field-Programmable Gate Array (FPGA) module, and it is made of mostly commerically available, integrated hardware and software components. It provides most of the functionality of our existing VME-based quench detection and protection system, but in addition the new system is easily scalable to protect multiple magnets powered independently and has a more powerful user interface and analysis tools. First applications of the new system will be for testing corrector coil packages. In this paper we describe the new system and present results of testing LHC Interaction Region Quadrupole (IRQ) correctors.

  19. An FPGA-based quench detection and protection system for superconducting accelerator magnets

    International Nuclear Information System (INIS)

    Carcagno, R.H.; Feher, S.; Lamm, M.; Makulski, A.; Nehring, R.; Orris, D.F.; Pischalnikov, Y.; Tartaglia, M.; Fermilab

    2005-01-01

    A new quench detection and protection system for superconducting accelerator magnets was developed for the Fermilab's Magnet Test Facility (MTF). This system is based on a Field-Programmable Gate Array (FPGA) module, and it is made of mostly commercially available, integrated hardware and software components. It provides all the functions of our existing VME-based quench detection and protection system, but in addition the new system is easily scalable to protect multiple magnets powered independently and a more powerful user interface and analysis tools. The new system has been used successfully for testing LHC Interaction Region Quadrupoles correctors and High Field Magnet HFDM04. In this paper we describe the system and present results

  20. An FPGA-based quench detection and protection system for superconducting accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.H.; Feher, S.; Lamm, M.; Makulski, A.; Nehring, R.; Orris, D.F.; Pischalnikov, Y.; Tartaglia, M.; /Fermilab

    2005-05-01

    A new quench detection and protection system for superconducting accelerator magnets was developed for the Fermilab's Magnet Test Facility (MTF). This system is based on a Field-Programmable Gate Array (FPGA) module, and it is made of mostly commercially available, integrated hardware and software components. It provides all the functions of our existing VME-based quench detection and protection system, but in addition the new system is easily scalable to protect multiple magnets powered independently and a more powerful user interface and analysis tools. The new system has been used successfully for testing LHC Interaction Region Quadrupoles correctors and High Field Magnet HFDM04. In this paper we describe the system and present results.

  1. A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

    International Nuclear Information System (INIS)

    Stinson, Brad J.; Kuhn, Michael J.; Donaldson, Terrence L.; Richardson, Dave; Rowe, Nathan C.; Younkin, James R.; Pickett, Chris A.

    2011-01-01

    Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensors vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this

  2. INTEGRATION OF ENVIRONMENTAL MANAGEMENT SYSTEM

    OpenAIRE

    Tomescu Ada Mirela

    2012-01-01

    The relevance of management as significant factor of business activity can be established on various management systems. These will help to obtain, organise, administrate, evaluate and control particulars: information, quality, environmental protection, health and safety, various resources (time, human, finance, inventory etc). The complexity of nowadays days development, forced us to think ‘integrated’. Sustainable development principles require that environment management policies and p...

  3. Integrity protection for code-on-demand mobile agents in e-commerce

    OpenAIRE

    Wang, TH; Guan, SU; Chan, TK

    2002-01-01

    The mobile agent paradigm has been proposed as a promising solution to facilitate distributed computing over open and heterogeneous networks. Mobility, autonomy, and intelligence are identified as key features of mobile agent systems and enabling characteristics for the next-generation smart electronic commerce on the Internet. However, security-related issues, especially integrity protection in mobile agent technology, still hinder the widespread use of software agents: from the agent’s pers...

  4. The Automatic Test Features of the IDiPS Reactor Protection System

    International Nuclear Information System (INIS)

    Hur, Seop; Kim, Dong-Hoon; Hwang, In-Koo; Lee, Cheol-Kwon; Lee, Dong-Young

    2007-01-01

    The reactor protection system (RPS) is designed to minimize a propagation of abnormal or accident conditions of nuclear power plants. A digital RPS (Integrated Digital Protection System (IDiPS) RPS) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. To make good use of the advantages of the digital technology, it is necessary to improve the reliability and availability of a system through automatic test features including an on-line testing, a self-diagnostics, an auto calibration, etc. This paper summarizes the system test strategy and the automatic test features of the IDiPS RPS

  5. Post-acute care and vertical integration after the Patient Protection and Affordable Care Act.

    Science.gov (United States)

    Shay, Patrick D; Mick, Stephen S

    2013-01-01

    The anticipated changes resulting from the passage of the Patient Protection and Affordable Care Act-including the proposed adoption of bundled payment systems and the promotion of accountable care organizations-have generated considerable controversy as U.S. healthcare industry observers debate whether such changes will motivate vertical integration activity. Using examples of accountable care organizations and bundled payment systems in the American post-acute healthcare sector, this article applies economic and sociological perspectives from organization theory to predict that as acute care organizations vary in the degree to which they experience environmental uncertainty, asset specificity, and network embeddedness, their motivation to integrate post-acute care services will also vary, resulting in a spectrum of integrative behavior.

  6. Battery management systems with thermally integrated fire suppression

    Science.gov (United States)

    Bandhauer, Todd M.; Farmer, Joseph C.

    2017-07-11

    A thermal management system is integral to a battery pack and/or individual cells. It relies on passive liquid-vapor phase change heat removal to provide enhanced thermal protection via rapid expulsion of inert high pressure refrigerant during abnormal abuse events and can be integrated with a cooling system that operates during normal operation. When a thermal runaway event occurs and sensed by either active or passive sensors, the high pressure refrigerant is preferentially ejected through strategically placed passages within the pack to rapidly quench the battery.

  7. FPGA-Based Plant Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae [KEPCO E and C, Daejeon (Korea, Republic of)

    2011-08-15

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system.

  8. FPGA-Based Plant Protection System

    International Nuclear Information System (INIS)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae

    2011-01-01

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system

  9. SUSTAIN:Urban Modeling Systems Integrating Optimization and Economics

    Science.gov (United States)

    The System for Urban Stormwater Treatment and Analysis INtegration (SUSTAIN) was developed by the U.S. Environmental Protection Agency to support practitioners in developing cost-effective management plans for municipal storm water programs and evaluating and selecting Best Manag...

  10. What Is Energy Systems Integration? | Energy Systems Integration Facility |

    Science.gov (United States)

    NREL What Is Energy Systems Integration? What Is Energy Systems Integration? Energy systems integration (ESI) is an approach to solving big energy challenges that explores ways for energy systems to Research Community NREL is a founding member of the International Institute for Energy Systems Integration

  11. Protected string spectrum in AdS{sub 3}/CFT{sub 2} from worldsheet integrability

    Energy Technology Data Exchange (ETDEWEB)

    Baggio, Marco [Instituut voor Theoretische Fysica, KU Leuven,Celestijnenlaan 200D, B-3001 Leuven (Belgium); Sax, Olof Ohlsson [Nordita, Stockholm University and KTH Royal Institute of Technology,Roslagstullsbacken 23, SE-106 91 Stockholm (Sweden); Sfondrini, Alessandro [Institut für Theoretische Physik, ETH Zürich,Wolfgang-Pauli-Str. 27, 8093 Zürich (Switzerland); Stefański, Bogdan Jr. [Centre for Mathematical Science, City, University of London,Northampton Square, EC1V 0HB London (United Kingdom); Torrielli, Alessandro [Department of Mathematics, University of Surrey,Guildford, GU2 7XH (United Kingdom)

    2017-04-14

    We derive the protected closed-string spectra of AdS{sub 3}/CFT{sub 2} dual pairs with 16 supercharges at arbitrary values of the string tension and of the three-form fluxes. These follow immediately from the all-loop Bethe equations for the spectra of the integrable worldsheet theories. Further, representing the underlying integrable systems as spin chains, we find that their dynamics involves length-changing interactions and that protected states correspond to gapless excitations above the Berenstein-Maldacena-Nastase vacuum. In the case of AdS{sub 3}×S{sup 3}×T{sup 4} the degeneracies of such operators precisely match those of the dual CFT{sub 2} and the supergravity spectrum. On the other hand, we find that for AdS{sub 3}×S{sup 3}×S{sup 3}×S{sup 1} there are fewer protected states than previous supergravity calculations had suggested. In particular, protected states have the same su(2) charge with respect to the two three-spheres.

  12. Development of a Smart Residential Fire Protection System

    Directory of Open Access Journals (Sweden)

    Juhwan Oh

    2013-01-01

    Full Text Available Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual fire test suggests that the developed wireless system for the smart residential fire protection system is reliable in terms of sensors and their communication linkage.

  13. Basic principles, contents, and benefits of an integrated management system

    International Nuclear Information System (INIS)

    Schwarzin, Juergen

    2010-01-01

    The basic principles and contents of an integrated management system are presented. The report focuses on the benefits and the experience accumulated in using an integrated management system. Integrated management systems are characterized by 2 features in particular: - On the one hand, by a system holistically controlling and describing all processes within a company which are necessary to achieve the company policy and company goals as defined. - On the other hand, it combines in one integrated management system various different aspects (such as quality, environmental protection, and safety) and the resulting requirements. Successful implementation of an integrated management system requires a clear commitment by company management to the integrated management system serving as a management tool. Implementation must be assigned the appropriate importance in the company. It must not be viewed as an instrument preserving 'status quo.' Instead, it must be seen as a tool for long-term improvement of the company. Application of the integrated management system minimizes the probability of occurrence of events, but is not able to reduce it to zero. (orig.)

  14. Development of an Integrated Data Acquisition System for a Small Flight Probe

    Science.gov (United States)

    Swanson, Gregory T.; Empey, Daniel M.; Skokova, Kristina A.; Venkatapathy, Ethiraj

    2012-01-01

    In support of the SPRITE concept, an integrated data acquisition system has been developed and fabricated for preliminary testing. The data acquisition system has been designed to condition traditional thermal protection system sensors, store their data to an on-board memory card, and in parallel, telemeter to an external system. In the fall of 2010, this system was integrated into a 14 in. diameter, 45 degree sphere cone probe instrumented with thermal protection system sensors. This system was then tested at the NASA Ames Research Center Aerodynamic Heating Facility's arc jet at approximately 170 W/sq. cm. The first test in December 2010 highlighted hardware design issues that were redesigned and implemented leading to a successful test in February 2011.

  15. Energy Systems Integration Laboratory | Energy Systems Integration Facility

    Science.gov (United States)

    | NREL Integration Laboratory Energy Systems Integration Laboratory Research in the Energy Systems Integration Laboratory is advancing engineering knowledge and market deployment of hydrogen technologies. Applications include microgrids, energy storage for renewables integration, and home- and station

  16. SUBSURFACE REPOSITORY INTEGRATED CONTROL SYSTEM DESIGN

    International Nuclear Information System (INIS)

    Randle, D.C.

    2000-01-01

    The primary purpose of this document is to develop a preliminary high-level functional and physical control system architecture for the potential repository at Yucca Mountain. This document outlines an overall control system concept that encompasses and integrates the many diverse process and communication systems being developed for the subsurface repository design. This document presents integrated design concepts for monitoring and controlling the diverse set of subsurface operations. The Subsurface Repository Integrated Control System design will be composed of a series of diverse process systems and communication networks. The subsurface repository design contains many systems related to instrumentation and control (I andC) for both repository development and waste emplacement operations. These systems include waste emplacement, waste retrieval, ventilation, radiological and air monitoring, rail transportation, construction development, utility systems (electrical, lighting, water, compressed air, etc.), fire protection, backfill emplacement, and performance confirmation. Each of these systems involves some level of I andC and will typically be integrated over a data communications network throughout the subsurface facility. The subsurface I andC systems will also interface with multiple surface-based systems such as site operations, rail transportation, security and safeguards, and electrical/piped utilities. In addition to the I andC systems, the subsurface repository design also contains systems related to voice and video communications. The components for each of these systems will be distributed and linked over voice and video communication networks throughout the subsurface facility. The scope and primary objectives of this design analysis are to: (1) Identify preliminary system-level functions and interfaces (Section 6.2). (2) Examine the overall system complexity and determine how and on what levels the engineered process systems will be monitored

  17. Development of An Analytic Approach to Determine How Environmental Protection Agency’s Integrated Risk Information System (IRIS) Is Used by Non-EPA Decision Makers (Final Contractor Report)

    Science.gov (United States)

    EPA announced the availability of the final contractor report entitled, Development of an Analytic Approach to Determine How Environmental Protection Agency’s Integrated Risk Information System (IRIS) Is Used By Non EPA Decision Makers. This contractor report analyzed how ...

  18. Energy Systems Integration Facility Videos | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems Integration Facility Videos Energy Systems Integration Facility Integration Facility NREL + SolarCity: Maximizing Solar Power on Electrical Grids Redefining What's Possible for Renewable Energy: Grid Integration Robot-Powered Reliability Testing at NREL's ESIF Microgrid

  19. A Collaborative Analysis Tool for Integrating Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald

    1999-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. The deficiencies in the scramjet powered concept led to a revival of interest in Rocket-Based Combined-Cycle (RBCC) propulsion systems. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. At this point the transitions to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scram4jet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance.

  20. ECOSYSTEM SERVICES AND BEYOND: INTEGRATION OF ECOSYSTEM SCIENCE AND MULTIMEDIA EXPOSURE MODELING FOR ENVIRONMENTAL PROTECTION

    Science.gov (United States)

    Decision-making for ecosystem protection and resource management requires an integrative science and technology applied with a sufficiently comprehensive systems approach. Single media (e.g., air, soil and water) approaches that evaluate aspects of an ecosystem in a stressor-by-...

  1. Integrated occupational radiation exposure information system

    International Nuclear Information System (INIS)

    Hunt, H.W.

    1983-06-01

    The integrated (Occupational Radiation Exposure) data base information system has many advantages. Radiation exposure information is available to operating management in a more timely manner and in a more flexible mode. The ORE system has permitted the integration of scattered files and data to be stored in a more cost-effective method that permits easy and simultaneous access by a variety of users with different data needs. The external storage needs of the radiation exposure source documents are several orders of magnitude less through the use of the computer assisted retrieval techniques employed in the ORE system. Groundwork is being layed to automate the historical files, which are maintained to help describe the radiation protection programs and policies at any one point in time. The file unit will be microfilmed for topical indexing on the ORE data base

  2. Low-Cost and Low-Temperature Integration Methods for System-in-Package

    NARCIS (Netherlands)

    Palacios Aguilera, N.B.

    2013-01-01

    Packaging has evoluted for years with the sole purpose of protecting the electronics from the environment and providing a suitable operating environment. Integration became a necessity and technologies as System-in-Package emerged and enabled the integration of components built with different

  3. Sandia's experience in designing and implementing integrated high security physical protection systems

    International Nuclear Information System (INIS)

    Caskey, D.L.

    1986-01-01

    As DOE's lead laboratory for physical security, Sandia National Laboratories has had a major physical security program for over ten years. Activities have ranged from component development and evaluation, to full scale system design and implementation. This paper presents some of the lessons learned in designing and implementing state-of-the-art high security physical protection systems for a number of government facilities. A generic system design is discussed for illustration purposes. Sandia efforts to transfer technology to industry are described

  4. Reactor protection systems for the Replacement Research Reactor, ANSTO

    International Nuclear Information System (INIS)

    Morris, C.R.

    2003-01-01

    The 20-MW Replacement Research Reactor Project which is currently under construction at ANSTO will have a combination of a state of the art triplicated computer based reactor protection system, and a fully independent, and diverse, triplicated analogue reactor protection system, that has been in use in the nuclear industry, for many decades. The First Reactor Protection System (FRPS) consists of a Triconex triplicated modular redundant system that has recently been approved by the USNRC for use in the USA?s power reactor program. The Second Reactor Protection System is a hardwired analogue system supplied by Foxboro, the Spec 200 system, which is also Class1E qualified. The FRPS is used to drop the control rods when its safety parameter setpoints have been reached. The SRPS is used to drain the reflector tank and since this operation would result in a reactor poison out due to the time it would take to refill the tank the FRPS trip setpoints are more limiting. The FRPS and SRPS have limited hardwired indications on the control panels in the main control room (MCR) and emergency control centre (ECC), however all FRPS and SRPS parameters are capable of being displayed on the reactor control and monitoring system (RCMS) video display units. The RCMS is a Foxboro Series I/A control system which is used for plant control and monitoring and as a protection system for the cold neutron source. This paper will provide technical information on both systems, their trip logics, their interconnections with each other, and their integration into the reactor control and monitoring system and control panels. (author)

  5. Systems integration.

    Science.gov (United States)

    Siemieniuch, C E; Sinclair, M A

    2006-01-01

    The paper presents a view of systems integration, from an ergonomics/human factors perspective, emphasising the process of systems integration as is carried out by humans. The first section discusses some of the fundamental issues in systems integration, such as the significance of systems boundaries, systems lifecycle and systems entropy, issues arising from complexity, the implications of systems immortality, and so on. The next section outlines various generic processes for executing systems integration, to act as guides for practitioners. These address both the design of the system to be integrated and the preparation of the wider system in which the integration will occur. Then the next section outlines some of the human-specific issues that would need to be addressed in such processes; for example, indeterminacy and incompleteness, the prediction of human reliability, workload issues, extended situation awareness, and knowledge lifecycle management. For all of these, suggestions and further readings are proposed. Finally, the conclusions section reiterates in condensed form the major issues arising from the above.

  6. Energy Systems Integration News | Energy Systems Integration Facility |

    Science.gov (United States)

    the Energy Systems Integration Facility as part of NREL's work with SolarCity and the Hawaiian Electric Companies. Photo by Amy Glickson, NREL Welcome to Energy Systems Integration News, NREL's monthly date on the latest energy systems integration (ESI) developments at NREL and worldwide. Have an item

  7. An Intrusion Detection System for the Protection of Railway Assets Using Fiber Bragg Grating Sensors

    Directory of Open Access Journals (Sweden)

    Angelo Catalano

    2014-09-01

    Full Text Available We demonstrate the ability of Fiber Bragg Gratings (FBGs sensors to protect large areas from unauthorized activities in railway scenarios such as stations or tunnels. We report on the technological strategy adopted to protect a specific depot, representative of a common scenario for security applications in the railway environment. One of the concerns in the protection of a railway area centers on the presence of rail-tracks, which cannot be obstructed with physical barriers. We propose an integrated optical fiber system composed of FBG strain sensors that can detect human intrusion for protection of the perimeter combined with FBG accelerometer sensors for protection of rail-track access. Several trials were carried out in indoor and outdoor environments. The results demonstrate that FBG strain sensors bonded under a ribbed rubber mat enable the detection of intruder break-in via the pressure induced on the mat, whereas the FBG accelerometers installed under the rails enable the detection of intruders walking close to the railroad tracks via the acoustic surface waves generated by footsteps. Based on a single enabling technology, this integrated system represents a valuable intrusion detection system for railway security and could be integrated with other sensing functionalities in the railway field using fiber optic technology.

  8. Power system protection

    International Nuclear Information System (INIS)

    Venkata, S.S.; Damborg, M.J.; Jampala, A.K.

    1991-01-01

    Power systems of the 21st century will be more modern, and complex, utilizing the latest available technologies. At the same time, generating plants will have to operate with minimal spinning margins and energy transportation has to take place at critical levels due to environmental and economical constraints. These factors dictate that the power systems be protected with optimum sensitivity, selectivity and time of operation to assure maximum reliability, and security at minimal cost. With an increasing role played by digital computers in every aspect of protection, it is important to take a critical and fresh look at the art and science of relaying and protection. The main objective of this paper is to review the past, present and future of power system protection from a software point of view

  9. Real-time information and processing system for radiation protection

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, M.; Badea, E.; Guta, V.

    1999-01-01

    The real-time information and processing system has as main task to record, collect, process and transmit the radiation level and weather data, being proposed for radiation protection, environmental monitoring around nuclear facilities and for civil defence. Such a system can offer information in order to provide mapping, data base, modelling and communication and to assess the consequences of nuclear accidents. The system incorporates a number of stationary or mobile radiation monitoring equipment, weather parameter measuring station, a GIS-based information processing center and the communication network, all running on a real-time operating system. It provides the automatic data collection on-line and off-line, remote diagnostic, advanced presentation techniques, including a graphically oriented executive support, which has the ability to respond to an emergency by geographical representation of the hazard zones on the map.The system can be integrated into national or international environmental monitoring systems, being based on local intelligent measuring and transmission units, simultaneous processing and data presentation using a real-time operating system for PC and geographical information system (GIS). Such an integrated system is composed of independent applications operating under the same computer, which is capable to improve the protection of the population and decision makers efforts, updating the remote GIS data base. All information can be managed directly from the map by multilevel data retrieving and presentation by using on-line dynamic evolution of the events, environment information, evacuation optimization, image and voice processing

  10. Development of Uncertainty Analysis Method for SMART Digital Core Protection and Monitoring System

    International Nuclear Information System (INIS)

    Koo, Bon Seung; In, Wang Kee; Hwang, Dae Hyun

    2012-01-01

    The Korea Atomic Energy Research Institute has developed a system-integrated modular advanced reactor (SMART) for a seawater desalination and electricity generation. Online digital core protection and monitoring systems, called SCOPS and SCOMS respectively were developed. SCOPS calculates minimum DNBR and maximum LPD based on the several online measured system parameters. SCOMS calculates the variables of limiting conditions for operation. KAERI developed overall uncertainty analysis methodology which is used statistically combining uncertainty components of SMART core protection and monitoring system. By applying overall uncertainty factors in on-line SCOPS/SCOMS calculation, calculated LPD and DNBR are conservative with a 95/95 probability/confidence level. In this paper, uncertainty analysis method is described for SMART core protection and monitoring system

  11. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  12. NSSS Component Control System Design of Integral Reactor

    International Nuclear Information System (INIS)

    Lee, Joon Koo; Kwon, Ho Je; Jeong, Kwong Il; Park, Heui Youn; Koo, In Soo

    2005-01-01

    MMIS(Man Machine Interface System) of an integral reactor is composed of a Control Room, Plant Protection System, Control System and Monitoring System which are related with the overall plant operation. MMIS is being developed with a new design concept and digital technology to reduce the Human Factor Error and improve the systems' safety, reliability and availability. And CCS(component control system) is also being developed with a new design concept and digital hardware technology A fully digitalized system and design concept are introduced in the NSSS CCS

  13. Design of integrated safeguards systems for nuclear facilities

    International Nuclear Information System (INIS)

    de Montmollin, J.M.; Walton, R.B.

    1976-01-01

    Safeguards systems that are capable of countering postulated threats to nuclear facilities must be closely integrated with plant layout and processes if they are to be effective and if potentially severe impacts on plant operations are to be averted. A facilities safeguards system suitable for a production plant is described in which the traditional elements of physical protection and periodic material-balance accounting are extended and augmented to provide close control of material flows. Discrete material items are subjected to direct, overriding physical control where appropriate. Materials in closely coupled process streams are protected by on-line NDA and weight measurements, with rapid computation of material balances to provide immediate indication of large-scale diversion. The system provides an information and actions at the safeguards/operations interface

  14. Design of integrated safeguards systems for nuclear facilities

    International Nuclear Information System (INIS)

    de Montmollin, J.M.; Walton, R.B.

    1978-06-01

    Safeguards systems that are capable of countering postulated threats to nuclear facilities must be closely integrated with plant layout and processes if they are to be effective and if potentially-severe impacts on plant operations are to be averted. This paper describes a facilities safeguards system suitable for production plant, in which the traditional elements of physical protection and periodic material-balance accounting are extended and augmented to provide close control of material flows. Discrete material items are subjected to direct, overriding physical control where appropriate. Materials in closely-coupled process streams are protected by on-line NDA and weight measurements, with rapid computation of material balances to provide immediate indication of large-scale diversion. The system provides information and actions at the safeguards/operations interface

  15. FIRE PROTECTION SYSTEMS AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Aristov Denis Ivanovich

    2016-03-01

    Full Text Available The All-Russian Congress “Fire Stop Moscow” was de-voted to the analysis of the four segments of the industry of fire protection systems and technologies: the design of fire protec-tion systems, the latest developments and technologies of active and passive fire protection of buildings, the state and the devel-opment of the legal framework, the practice of fire protection of buildings and structures. The forum brought together the repre-sentatives of the industry of fire protection systems, scientists, leading experts, specialists in fire protection and representatives of construction companies from different regions of Russia. In parallel with the Congress Industrial Exhibition of fire protection systems, materials and technology was held, where manufacturers presented their products. The urgency of the “Fire Stop Moscow” Congress in 2015 organized by the Congress Bureau ODF Events lies primarily in the fact that it considered the full range of issues related to the fire protection of building and construction projects; studied the state of the regulatory framework for fire safety and efficiency of public services, research centers, private companies and busi-nesses in the area of fire safety. The main practical significance of the event which was widely covered in the media space, was the opportunity to share the views and information between management, science, and practice of business on implementing fire protection systems in the conditions of modern economic relations and market realities. : congress, fire protection, systems, technologies, fire protection systems, exhibition

  16. Integrated Compliance Information System (ICIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The purpose of ICIS is to meet evolving Enforcement and Compliance business needs for EPA and State users by integrating information into a single integrated data...

  17. 45 CFR 61.14 - Confidentiality of Healthcare Integrity and Protection Data Bank information.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Confidentiality of Healthcare Integrity and Protection Data Bank information. 61.14 Section 61.14 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION HEALTHCARE INTEGRITY AND PROTECTION DATA BANK FOR FINAL ADVERSE INFORMATION ON...

  18. Optimal loading and protection of multi-state systems considering performance sharing mechanism

    International Nuclear Information System (INIS)

    Xiao, Hui; Shi, Daimin; Ding, Yi; Peng, Rui

    2016-01-01

    Engineering systems are designed to carry the load. The performance of the system largely depends on how much load it carries. On the other hand, the failure rate of the system is strongly affected by its load. Besides internal failures, such as fatigue and aging process, systems may also fail due to external impacts such as nature disasters and terrorism. In this paper, we integrate the effect of loading and protection of external impacts on multi-state systems with performance sharing mechanism. The objective of this research is to determine how to balance the load and protection on system elements. An availability evaluation algorithm of the proposed system is suggested and the corresponding optimization problem is solved utilizing genetic algorithms. - Highlights: • Performance sharing of multi-state systems is considered. • The effect of load on system elements is analyzed. • Joint optimization model of element loading and protection is formulated. • Genetic Algorithms are adapted to solve the reliability optimization problem.

  19. Reliability analysis of protection system of advanced pressurized water reactor - APR 1400

    International Nuclear Information System (INIS)

    Varde, P. V.; Choi, J. G.; Lee, D. Y.; Han, J. B.

    2003-04-01

    Reliability analysis was carried out for the protection system of the Korean Advanced Pressurized Water Reactor - APR 1400. The main focus of this study was the reliability analysis of digital protection system, however, towards giving an integrated statement of complete protection reliability an attempt has been made to include the shutdown devices and other related aspects based on the information available to date. The sensitivity analysis has been carried out for the critical components / functions in the system. Other aspects like importance analysis and human error reliability for the critical human actions form part of this work. The framework provided by this study and the results obtained shows that this analysis has potential to be utilized as part of risk informed approach for future design / regulatory applications

  20. French experience in using programmable systems for the control and the protection of nuclear reactors

    International Nuclear Information System (INIS)

    Jover, P.

    1986-01-01

    The paper presents the results obtained in the use of two automated systems important to safety in 1300 MWE French nuclear reactors: the numerical integrated protection system (SPIN) and the logical control system (CONTROBLOC)

  1. An integrated approach for integrated intelligent instrumentation and control system (I3CS)

    International Nuclear Information System (INIS)

    Jung, C.H.; Kim, J.T.; Kwon, K.C.

    1997-01-01

    Nuclear power plants to guarantee the safety of public should be designed to reduce the operator intervention resulting in operating human errors, identify the process states in transients, and aid to make a decision of their tasks and guide operator actions. For the sake of this purpose, MMIS(MAN-Machine Interface System) in NPPs should be the integrated top-down approach tightly focused on the function-based task analysis including an advanced digital technology, an operator support function, and so on. The advanced I and C research team in KAERI has embarked on developing an Integrated Intelligent Instrumentation and Control System (I 3 CS) for Korea's next generation nuclear power plants. I 3 CS bases the integrated top-down approach on the function-based task analysis, modern digital technology, standardization and simplification, availability and reliability, and protection of investment. (author). 4 refs, 6 figs

  2. Expert systems for protective monitoring of facilities

    International Nuclear Information System (INIS)

    Carr, K.R.

    1987-01-01

    In complex plants, the possibility of serious operator error always exists to some extent, but, this can be especially true during an experiment or some other unusual exercise. Possible contributing factors to operational error include personnel fatigue, misunderstanding in communication, mistakes in executing orders, uncertainty about the delegated authority, pressure to meet a demanding schedule, and a lack of understanding of the possible consequences of deliberate violations of the facility's established operating procedures. Authoritative reports indicate that most of these factors were involved in the disastrous Russian Chernobyl-4 nuclear reactor accident in April 1986, which, ironically, occurred when a safety experiment was being conducted. Given the computer hardware and software now available for implementing expert systems together with integrated signal monitoring and communications, plant protection could be enhanced by an expert system with extended features to monitor the plant. The system could require information from the operators on a rigidly enforced schedule and automatically log in and report on a scheduled time basis to authorities at a central remote site during periods of safe operation. Additionally, the system could warn an operator or automatically shut down the plant in case of dangerous conditions, while simultaneously notifying independent, responsible, off-site personnel of the action taken. This approach would provide protection beyond that provided by typical facility scram circuits. This paper presents such an approach to implementing an expert system for plant protection, together with specific hardware and software configurations. The Chernobyl accident is used as the basis of discussion

  3. Verification and validation guidelines for high integrity systems: Appendices A--D, Volume 2

    International Nuclear Information System (INIS)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D.

    1995-03-01

    The following material is furnished as an experimental guide for the use of risk based classification for nuclear plant protection systems. As shown in Sections 2 and 3 of this report, safety classifications for the nuclear field are application based (using the function served as the primary criterion), whereas those in use by the process industry and the military are risk based. There are obvious obstacles to the use of risk based classifications (and the associated integrity levels) for nuclear power plants, yet there are also many potential benefits, including: it considers all capabilities provided for dealing with a specific hazard, thus assigning a lower risk where multiple protection is provided (either at the same or at lower layers); this permits the plant management to perform trade-offs between systems that meet the highest qualification levels or multiple diverse systems at lower qualification levels; it motivates the use (and therefore also the development) of protection systems with demonstrated low failure probability; and it may permit lower cost process industry equipment of an established integrity level to be used in nuclear applications (subject to verification of the integrity level and regulatory approval). The totality of these benefits may reduce the cost of digital protection systems significantly an motivate utilities to much more rapid upgrading of the capabilities than is currently the case. Therefore the outline of a risk based classification is presented here, to serve as a starting point for further investigation and possible trial application

  4. Reactor protection system

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Lesniak, L.M.; Orgera, E.G.

    1977-10-01

    The report describes the reactor protection system (RPS-II) designed for use on Babcock and Wilcox 145-, later 177-, and 205-fuel assembly pressurized water reactors. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low-pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, a description of the software programmed in the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W

  5. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  6. Systems approach to tamper protection

    International Nuclear Information System (INIS)

    Myre, W.C.; Eaton, M.J.

    1980-01-01

    Tamper-protection is a fundamental requirement of effective containment and surveillance systems. Cost effective designs require that the tamper protection requirements be considered early in the design phase and at the system level. A discussion of tamper protection alternatives as well as an illustrative example system is presented

  7. Integration of radiation protection in occupational health and safety managementsystems - legal requirements and practical realization at the example of the Fraunhofer occupational health and safety management system FRAM

    International Nuclear Information System (INIS)

    Lambotte, S.; Severitt, S.; Weber, U.

    2002-01-01

    The protection of the employees, the people and the environment for the effects of radiation is regulated by numerous laws and rules set by the government and the occupational accident insurances. Primarily these rules apply for the responsibles, normally the employer, as well as for the safety officers. Occupational safety management systems can support these people to carry out their tasks and responsibilities effectively. Also, a systematic handling of the organisation secures that the numerous duties of documentation, time-checking of the proof-lists and dates are respected. Further more, the legal certainty for the responsibles and safety officers will be raised and the occupational, environment, radiation and health protection will be promoted. At the example of the Fraunhofer occupational safety management system (FrAM) it is demonstrated, how radiation protection (ionizing radiation) can be integrated in a progressive intranet supported management system. (orig.)

  8. Energy Systems Integration News - October 2016 | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL October 2016 Energy Systems Integration News A monthly recap of the latest energy systems integration (ESI) developments at NREL and around the world. Subscribe Archives October Integration Facility's main control room. OMNETRIC Group Demonstrates a Distributed Control Hierarchy for

  9. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  10. Integrated multisensor perimeter detection systems

    Science.gov (United States)

    Kent, P. J.; Fretwell, P.; Barrett, D. J.; Faulkner, D. A.

    2007-10-01

    The report describes the results of a multi-year programme of research aimed at the development of an integrated multi-sensor perimeter detection system capable of being deployed at an operational site. The research was driven by end user requirements in protective security, particularly in threat detection and assessment, where effective capability was either not available or prohibitively expensive. Novel video analytics have been designed to provide robust detection of pedestrians in clutter while new radar detection and tracking algorithms provide wide area day/night surveillance. A modular integrated architecture based on commercially available components has been developed. A graphical user interface allows intuitive interaction and visualisation with the sensors. The fusion of video, radar and other sensor data provides the basis of a threat detection capability for real life conditions. The system was designed to be modular and extendable in order to accommodate future and legacy surveillance sensors. The current sensor mix includes stereoscopic video cameras, mmWave ground movement radar, CCTV and a commercially available perimeter detection cable. The paper outlines the development of the system and describes the lessons learnt after deployment in a pilot trial.

  11. Innovative protection and control systems for a reliable and secure operation of electrical transmission systems; Innovative Schutz- und Leitsysteme zur zuverlaessigen und sicheren elektrischen Energieuebertragung

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Sven C.; Kubis, Adreas; Rehtanz, Christian [Technische Univ. Dortmund (Germany). Inst. fuer Energiesysteme, Energieeffizienz und Energiewirtschaft (ie3); Brato, Sebastian; Goetze, Juergen [Technische Univ. Dortmund (Germany). Arbeitsgebiet Datentechnik

    2012-07-01

    The integration of European electricity markets as well as the increasing power feed-in by renewable energy sources pose new challenges to the operation of electrical transmission systems. Modern protection and control systems based on wide-area information can substantially contribute to a reliable and secure system operation even against the background of future demands. In this paper research advances regarding new applications for wide-area monitoring, protection and control as well as an integrated simulation for power and ICT systems are presented that have been developed in the course of DFG research unit FOR1511 at TU Dortmund. (orig.)

  12. SMART core protection system design

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, H. Y.; Koo, I. S.; Park, H. S.; Kim, J. S.; Son, C. H.

    2003-01-01

    SMART COre Protection System(SCOPS) is designed with real-tims Digital Signal Processor(DSP) board and Network Interface Card(NIC) board. SCOPS has a Control Rod POSition (CRPOS) software module while Core Protection Calculator System(CPCS) consists of Core Protection Calculators(CPCs) and Control Element Assembly(CEA) Calculators(CEACs) in the commercial nuclear plant. It's not necessary to have a independent cabinets for SCOPS because SCOPS is physically very small. Then SCOPS is designed to share the cabinets with Plant Protection System(PPS) of SMART. Therefor it's very easy to maintain the system because CRPOS module is used instead of the computer with operating system

  13. Information Security and Integrity Systems

    Science.gov (United States)

    1990-01-01

    Viewgraphs from the Information Security and Integrity Systems seminar held at the University of Houston-Clear Lake on May 15-16, 1990 are presented. A tutorial on computer security is presented. The goals of this tutorial are the following: to review security requirements imposed by government and by common sense; to examine risk analysis methods to help keep sight of forest while in trees; to discuss the current hot topic of viruses (which will stay hot); to examine network security, now and in the next year to 30 years; to give a brief overview of encryption; to review protection methods in operating systems; to review database security problems; to review the Trusted Computer System Evaluation Criteria (Orange Book); to comment on formal verification methods; to consider new approaches (like intrusion detection and biometrics); to review the old, low tech, and still good solutions; and to give pointers to the literature and to where to get help. Other topics covered include security in software applications and development; risk management; trust: formal methods and associated techniques; secure distributed operating system and verification; trusted Ada; a conceptual model for supporting a B3+ dynamic multilevel security and integrity in the Ada runtime environment; and information intelligence sciences.

  14. Evolution of the radiation protection system; L'evolution du systeme de protection radiologique

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, R.H. [International Commission on Radiological Protection, Stockholm (Sweden); Schieber, C.; Cordoliani, Y.S. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Brechignac, F. [CEA Cadarache, Institut de Radioprotection et de Surete Nucleaire, Dept. de Protection de l' Environnement, 13 - Saint Paul Lez Durance (France)

    2003-07-01

    The evolution of the system of radiological protection: justification for new ICRP recommendations, thoughts of the SFRP work group about the evolution of the system of radiation protection proposed by the ICRP, protection of environment against ionizing radiations seen by the ICRP are the three parts of this chapter. (N.C.)

  15. Early warning of illegal development for protected areas by integrating cellular automata with neural networks.

    Science.gov (United States)

    Li, Xia; Lao, Chunhua; Liu, Yilun; Liu, Xiaoping; Chen, Yimin; Li, Shaoying; Ai, Bing; He, Zijian

    2013-11-30

    Ecological security has become a major issue under fast urbanization in China. As the first two cities in this country, Shenzhen and Dongguan issued the ordinance of Eco-designated Line of Control (ELC) to "wire" ecologically important areas for strict protection in 2005 and 2009 respectively. Early warning systems (EWS) are a useful tool for assisting the implementation ELC. In this study, a multi-model approach is proposed for the early warning of illegal development by integrating cellular automata (CA) and artificial neural networks (ANN). The objective is to prevent the ecological risks or catastrophe caused by such development at an early stage. The integrated model is calibrated by using the empirical information from both remote sensing and handheld GPS (global positioning systems). The MAR indicator which is the ratio of missing alarms to all the warnings is proposed for better assessment of the model performance. It is found that the fast urban development has caused significant threats to natural-area protection in the study area. The integration of CA, ANN and GPS provides a powerful tool for describing and predicting illegal development which is in highly non-linear and fragmented forms. The comparison shows that this multi-model approach has much better performances than the single-model approach for the early warning. Compared with the single models of CA and ANN, this integrated multi-model can improve the value of MAR by 65.48% and 5.17% respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. The Piranha Solution: Monitoring and Protection of Proprietary System Intangible Assets

    Science.gov (United States)

    Ladwig, Christine; Schwieger, Dana; Clayton, Donald

    2017-01-01

    The "Piranha Solution"® is a complex and valuable integrated chemical supply inventory management system protected as a trade secret by its asset holder, the Confluence Corporation. The "Piranha" program is the lifeblood of the corporation's growth and success in the chemical supply industry. A common definition of "trade…

  17. Energy Systems Integration Facility News | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems Integration Facility News Energy Systems Integration Facility Energy Dataset A massive amount of wind data was recently made accessible online, greatly expanding the Energy's National Renewable Energy Laboratory (NREL) has completed technology validation testing for Go

  18. 45 CFR 61.12 - Requesting information from the Healthcare Integrity and Protection Data Bank.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Requesting information from the Healthcare Integrity and Protection Data Bank. 61.12 Section 61.12 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION HEALTHCARE INTEGRITY AND PROTECTION DATA BANK FOR FINAL ADVERSE INFORMATION...

  19. An integrated approach for integrated intelligent instrumentation and control system (I{sup 3}CS)

    Energy Technology Data Exchange (ETDEWEB)

    Jung, C H; Kim, J T; Kwon, K C [Korea Atomic Energy Research Inst., Yusong, Taejon (Korea, Republic of)

    1997-07-01

    Nuclear power plants to guarantee the safety of public should be designed to reduce the operator intervention resulting in operating human errors, identify the process states in transients, and aid to make a decision of their tasks and guide operator actions. For the sake of this purpose, MMIS(MAN-Machine Interface System) in NPPs should be the integrated top-down approach tightly focused on the function-based task analysis including an advanced digital technology, an operator support function, and so on. The advanced I and C research team in KAERI has embarked on developing an Integrated Intelligent Instrumentation and Control System (I{sup 3}CS) for Korea`s next generation nuclear power plants. I{sup 3}CS bases the integrated top-down approach on the function-based task analysis, modern digital technology, standardization and simplification, availability and reliability, and protection of investment. (author). 4 refs, 6 figs.

  20. Effect of Remote Back-Up Protection System Failure on the Optimum Routine Test Time Interval of Power System Protection

    Directory of Open Access Journals (Sweden)

    Y Damchi

    2013-12-01

    Full Text Available Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.

  1. Reliability modeling of digital component in plant protection system with various fault-tolerant techniques

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Kim, Hee Eun; Lee, Seung Jun; Seong, Poong Hyun

    2013-01-01

    Highlights: • Integrated fault coverage is introduced for reflecting characteristics of fault-tolerant techniques in the reliability model of digital protection system in NPPs. • The integrated fault coverage considers the process of fault-tolerant techniques from detection to fail-safe generation process. • With integrated fault coverage, the unavailability of repairable component of DPS can be estimated. • The new developed reliability model can reveal the effects of fault-tolerant techniques explicitly for risk analysis. • The reliability model makes it possible to confirm changes of unavailability according to variation of diverse factors. - Abstract: With the improvement of digital technologies, digital protection system (DPS) has more multiple sophisticated fault-tolerant techniques (FTTs), in order to increase fault detection and to help the system safely perform the required functions in spite of the possible presence of faults. Fault detection coverage is vital factor of FTT in reliability. However, the fault detection coverage is insufficient to reflect the effects of various FTTs in reliability model. To reflect characteristics of FTTs in the reliability model, integrated fault coverage is introduced. The integrated fault coverage considers the process of FTT from detection to fail-safe generation process. A model has been developed to estimate the unavailability of repairable component of DPS using the integrated fault coverage. The new developed model can quantify unavailability according to a diversity of conditions. Sensitivity studies are performed to ascertain important variables which affect the integrated fault coverage and unavailability

  2. Crowbar protection system for 350 MHz Tetrode Amplifer

    International Nuclear Information System (INIS)

    Shrotriya, Sandip; Pande, Manjiri; Handu, V.K.

    2009-01-01

    In an RF amplifier, the conventional anode DC power supply has filter capacitors which have high stored energy. In the event of short circuit/arc fault across the RF tube, this stored energy may get dumped there by causing permanent damage. Hence, high power RF tubes need to be protected. This requires a fast processing circuitry that will sense the fault current, trigger the crowbar system and then divert this stored energy in to a crowbar resistance instead of RF tube. It should simultaneously turn off the HVDC anode supply. A spark gap based protection system has been designed, developed, integrated and tested with the RF amplifier. A wire burn test has been performed successfully to ensure that stored energy of the capacitor will discharge in the crowbar resistance rather than in the tube. This paper presents details about spark-gap based crowbar, triggering circuit description, wire burn test set up and results of wire burn test. (author)

  3. An Approximate Ablative Thermal Protection System Sizing Tool for Entry System Design

    Science.gov (United States)

    Dec, John A.; Braun, Robert D.

    2006-01-01

    A computer tool to perform entry vehicle ablative thermal protection systems sizing has been developed. Two options for calculating the thermal response are incorporated into the tool. One, an industry-standard, high-fidelity ablation and thermal response program was integrated into the tool, making use of simulated trajectory data to calculate its boundary conditions at the ablating surface. Second, an approximate method that uses heat of ablation data to estimate heat shield recession during entry has been coupled to a one-dimensional finite-difference calculation that calculates the in-depth thermal response. The in-depth solution accounts for material decomposition, but does not account for pyrolysis gas energy absorption through the material. Engineering correlations are used to estimate stagnation point convective and radiative heating as a function of time. The sizing tool calculates recovery enthalpy, wall enthalpy, surface pressure, and heat transfer coefficient. Verification of this tool is performed by comparison to past thermal protection system sizings for the Mars Pathfinder and Stardust entry systems and calculations are performed for an Apollo capsule entering the atmosphere at lunar and Mars return speeds.

  4. Testing methodology of embedded software in digital plant protection system

    International Nuclear Information System (INIS)

    Seong, Ah Young; Choi, Bong Joo; Lee, Na Young; Hwang, Il Soon

    2001-01-01

    It is necessary to assure the reliability of software in order to digitalize RPS(Reactor Protection System). Since RPS causes fatal damage on accidental cases, it is classified as Safety 1E class. Therefore we propose the effective testing methodology to assure the reliability of embedded software in the DPPS(Digital Plant Protection System). To test the embedded software effectively in DPPS, our methodology consists of two steps. The first is the re-engineering step that extracts classes from structural source program, and the second is the level of testing step which is composed of unit testing, Integration Testing and System Testing. On each testing step we test the embedded software with selected test cases after the test item identification step. If we use this testing methodology, we can test the embedded software effectively by reducing the cost and the time

  5. Definition, analysis and development of an optical data distribution network for integrated avionics and control systems. Part 2: Component development and system integration

    Science.gov (United States)

    Yen, H. W.; Morrison, R. J.

    1984-01-01

    Fiber optic transmission is emerging as an attractive concept in data distribution onboard civil aircraft. Development of an Optical Data Distribution Network for Integrated Avionics and Control Systems for commercial aircraft will provide a data distribution network that gives freedom from EMI-RFI and ground loop problems, eliminates crosstalk and short circuits, provides protection and immunity from lightning induced transients and give a large bandwidth data transmission capability. In addition there is a potential for significantly reducing the weight and increasing the reliability over conventional data distribution networks. Wavelength Division Multiplexing (WDM) is a candidate method for data communication between the various avionic subsystems. With WDM all systems could conceptually communicate with each other without time sharing and requiring complicated coding schemes for each computer and subsystem to recognize a message. However, the state of the art of optical technology limits the application of fiber optics in advanced integrated avionics and control systems. Therefore, it is necessary to address the architecture for a fiber optics data distribution system for integrated avionics and control systems as well as develop prototype components and systems.

  6. Test and verification of a reactor protection system application-specific integrated circuit

    International Nuclear Information System (INIS)

    Battle, R.E.; Turner, G.W.; Vandermolen, R.I.; Vitalbo, C.

    1997-01-01

    Application-specific integrated circuits (ASICs) were utilized in the design of nuclear plant safety systems because they have certain advantages over software-based systems and analog-based systems. An advantage they have over software-based systems is that an ASIC design can be simple enough to not include branch statements and also can be thoroughly tested. A circuit card on which an ASIC is mounted can be configured to replace various versions of older analog equipment with fewer design types required. The approach to design and testing of ASICs for safety system applications is discussed in this paper. Included are discussions of the ASIC architecture, how it is structured to assist testing, and of the functional and enhanced circuit testing

  7. Integrated risk information system (IRIS)

    Energy Technology Data Exchange (ETDEWEB)

    Tuxen, L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRIS contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).

  8. Adaptive protection algorithm and system

    Science.gov (United States)

    Hedrick, Paul [Pittsburgh, PA; Toms, Helen L [Irwin, PA; Miller, Roger M [Mars, PA

    2009-04-28

    An adaptive protection algorithm and system for protecting electrical distribution systems traces the flow of power through a distribution system, assigns a value (or rank) to each circuit breaker in the system and then determines the appropriate trip set points based on the assigned rank.

  9. Advanced Worker Protection System

    International Nuclear Information System (INIS)

    1996-04-01

    The Advanced Worker Protection System (AWPS) is a liquid-air-based, self-contained breathing and cooling system with a duration of 2 hrs. AWPS employs a patented system developed by Oceaneering Space Systems (OSS), and was demonstrated at their facility in Houston, TX as well as at Kansas State University, Manhattan. The heart of the system is the life-support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack is combined with advanced protective garments, an advanced liquid cooling garment (LCG), a respirator, and communications and support equipment. The prototype unit development and testing under Phase 1 has demonstrated that AWPS has the ability to meet performance criteria. These criteria were developed with an understanding of both the AWPS capabilities and the DOE decontamination and decommissioning (D and D) activities protection needs

  10. A Protective Mechanism for the Access Control System in the Virtual Domain

    Institute of Scientific and Technical Information of China (English)

    Jinan Shen; Deqing Zou; Hai Jin; Kai Yang; Bin Yuan; Weiming Li

    2016-01-01

    In traditional framework,mandatory access control (MAC) system and malicious software are run in kernel mode.Malicious software can stop MAC systems to be started and make it do invalid.This problem cannot be solved under the traditional framework if the operating system (OS) is comprised since malwares are running in ring0 level.In this paper,we propose a novel way to use hypervisors to protect kernel integrity and the access control system in commodity operating systems.We separate the access control system into three parts:policy management (PM),security server (SS) and policy enforcement (PE).Policy management and the security server reside in the security domain to protect them against malware and the isolation feather of the hypervisor can protect them from attacks.We add an access vector cache (AVC) between SS and PE in the guest OS,in order to speed up communication between the guest OS and the security domain.The policy enforcement module is retained in the guest OS for performance.The security of AVC and PE can be ensured by using a memory protection mechanism.The goal of protecting the OS kemel is to ensure the security of the execution path.We implement the system by a modified Xen hypervisor.The result shows that we can secure the security of the access control system in the guest OS with no overhead compared with modules in the latter.Our system offers a centralized security policy for virtual domains in virtual machine environments.

  11. Protection of industrial power systems

    CERN Document Server

    DAVIES, T

    2006-01-01

    The protection which is installed on an industrial power system is likely to be subjected to more difficult conditions than the protection on any other kind of power system. Starting with the many simple devices which are employed and covering the whole area of industrial power system protection, this book aims to help achieve a thorough understanding of the protection necessary.Vital aspects such as the modern cartridge fuse, types of relays, and the role of the current transformer are covered and the widely used inverse definite-minimum time overcurrent relay, the theory of the M

  12. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    Directory of Open Access Journals (Sweden)

    Buha Danilo

    2016-01-01

    Full Text Available The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B" are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according to which the calculations are done are described. Criteria used to provide the protection to fulfill the backup protection role in the event of malfunction of the main protection of the transmission system. are clarified. The calculation of all protection functions (32 functions of generator B1 were performed in the project "Coordination of relay protection blocks B1 and B2 with the system of excitation and power system protections -TENT B".

  13. Promoting employee health by integrating health protection, health promotion, and continuous improvement: a longitudinal quasi-experimental intervention study.

    Science.gov (United States)

    von Thiele Schwarz, Ulrica; Augustsson, Hanna; Hasson, Henna; Stenfors-Hayes, Terese

    2015-02-01

    To test the effects of integrating health protection and health promotion with a continuous improvement system (Kaizen) on proximal employee outcomes (health promotion, integration, and Kaizen) and distal outcomes (workability, productivity, self-rated health and self-rated sickness absence). Twelve units in a county hospital in Sweden were randomized to control or intervention groups using a quasiexperimental study design. All staff (approximately 500) provided self-ratings in questionnaires at baseline, and a 12- and 24-month follow-up (response rate, 79% to 87.5%). There was a significant increase in the proximal outcomes over time in the intervention group compared with the control group, and a trend toward improvement in the distal outcomes workability and productivity. Integration seems to promote staff engagement in health protection and promotion, as well as to improve their understanding of the link between work and health.

  14. Energy saver/doubler quench protection monitor system

    International Nuclear Information System (INIS)

    Flora, R.; Saarivirta, J.; Tool, G.; Voy, D.

    1981-01-01

    The microprocessor based system to detect quenches in the superconducting magnets is described. Tests conducted over the past two years using a string of twenty superconducting magnets have yielded results having major impact on the design of this system. A network of twenty-four 16-bit microprocessors will monitor the integrated voltage across magnet protection units every 60 Hz line period using isolated voltage to frequency converters. These measurements are compared with the inductive voltage expected. Under transient conditions, the distributed L-C nature of the magnets delays signal propagation as in a transmission line. To achieve the required sensitivity of resistive voltage detection, the inductive voltage for each magnet cell is calculated using two of the six measured dI/dt signals. 5 refs

  15. Protective and Catching Safety Systems In Construction

    Directory of Open Access Journals (Sweden)

    Kuzhin Marat

    2017-01-01

    Full Text Available In the article is described application of protective and catching systems in construction. Classification of similar systems, their types and purpose are listed. Dangerous zones on construction site and events to for limiting their influence or protection from the factors. Protective and catching systems is one of the most effective technical equipment, applied in recent time. Protective fences and catching systems are important part in the problem solution. Protective fences protect workers from falling from height. Protective and catching systems allows avoid injuries by workers, also catch debris, fallen from constructing buildings. In regard with continuing development in technical and technological solutions, protective and catching systems require adaptation to a new requirements of construction industry and requirements of normative documents. Technical regulations in the appliance sphere of protective and catching systems requires actualization and aligning with modern normatives. Important role should be given to developing organizational and technological documentation for application of the systems. Scientific studying of technical parameters of fences and protective catching nets also has great interest.

  16. Central system of Interlock of ITER, high integrity architecture

    International Nuclear Information System (INIS)

    Prieto, I.; Martinez, G.; Lopez, C.

    2014-01-01

    The CIS (Central Interlock System), along with the CODAC system and CSS (Central Safety System), form the central I and C systems of ITER. The CIS is responsible for implementing the core functions of protection (Central Interlock Functions) through different systems of plant (Plant Systems) within the overall strategy of investment protection for ITER. IBERDROLA supports engineering to define and develop the control architecture of CIS according to the stringent requirements of integrity, availability and response time. For functions with response times of the order of half a second is selected PLC High availability of industrial range. However, due to the nature of the machine itself, certain functions must be able to act under the millisecond, so it has had to develop a solution based on FPGA (Field Programmable Gate Array) capable of meeting the requirements architecture. In this article CIS architecture is described, as well as the process for the development and validation of the selected platforms. (Author)

  17. Multi-agent approach for power system in a smart grid protection context

    DEFF Research Database (Denmark)

    Abedini, Reza; Pinto, Tiago; Morais, Hugo

    2013-01-01

    electricity markets and in the other hand with increasing penetration of Distributed Generation (DG) because of environment issues and diminishing in fossil fuel reserves and its price growth, made microgrid more attractive. Micro grids are considers as partial of SmartGrid system to accommodate DGs as well......With increasing penetration of electricity application in society and the need of majority of appliance to electricity, high level of reliability becomes more essential; in one hand with deregulation of electricity market in production, transmission and distribution and emerge of competitive...... proposes a new approach for protection in a Microgrid environment as a part of SmartGrid: Multi-agent system to Protections Coordination (MAS-ProteC) which integrated in MASGriP (Multi-Agent Smart Grid Platform), providing protection services within network operation in SmartGrid in electricity market...

  18. Smart machine protection system

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.

    1992-01-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerators to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is complied into a logical decision tree for the 68030 processor. (author)

  19. Smart Machine Protection System

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.; Spencer, N.; Hutchinson, D.; Olsen, J.; Millsom, D.; White, G.; Gromme, T.; Allison, S.; Underwood, K.; Zelazny, M.; Kang, H.

    1991-11-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerator to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is compiled into a logical decision tree for the 68030 processor. 3 figs

  20. Advantages and Limitations of Integrated Management System: the Theoretical Viewpoint

    Directory of Open Access Journals (Sweden)

    Agota Giedrė Raišienė

    2013-08-01

    integrated management systems implementation studies in Lithuanian scientific literature. That hinders the possibility to frame specific recommendations to the practicians in Lithuania.Practical implications and value. In the contemporary world, coordination and supervision of management systems is a complex aim, which needs constant redesigning and innovations; organizations are challenged to optimize their management constantly. One of potentialities can be implementing an integrated management system. Traditionally, it consists of the quality management, employees’ health and safety management, social responsibility management and environmental protection management migration to one management system. As there is no international standard, that would submit unambiguous recommendations about ensuring the management system integration, every organization copes with this assignment on it‘s own. The paper gives value both to managers and to scientists who are interested in advantages and limitations of integrated management systems in general because of a generalized systemic approach to the research issue.Research type: viewpoint and conceptual paper.

  1. Integrating Ecosystem Management, Protected Areas, and Mammal Conservation in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Claudia Azevedo-Ramos

    2006-12-01

    Full Text Available The Amazon forest has been converted to a matrix of pristine and modified habitats. Landscape-scale biodiversity conservation requires an understanding of species' distributions over this matrix to guarantee both effective protection and use for present and future generations. In this study, we evaluated how much of the existing and future planned protected areas (PAs would be contributing to the conservation of Brazilian Amazon mammals (N = 399, including threatened species (N = 51. Currently, almost 37% of Brazilian Amazon is protected and that may increase to 46% if planned PAs are implemented. In the current PA system, 22% are indigenous land and 11% are sustainable use units, e.g., production forests. Only one-fifth of the whole range of mammal species occurring in Brazilian Amazon is actually protected by Brazilian PAs. However, considering only the part of the ranges within the Brazilian Amazon, and therefore under the scope of Brazilian actions, Brazilian PAs assume an important role in the protection of 39% of mammal distribution ranges, particularly the threatened species (39%. These results suggest that an integrated network of protected areas among Amazon countries would be necessary to increase their efficiency in mammal conservation. The need for strengthening of the forest sector and good management practices in Brazil appears critical for the maintenance of large extents of forest and species conservation. Under such a scenario, the contribution of developed nations and international agencies must assume an important role for the maintenance and enlargement of the protected area network in Amazon region.

  2. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system

  3. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system. 8 refs

  4. Design of an integrated I and C system

    International Nuclear Information System (INIS)

    Lee, C. K.; Oh, I. S.; Kim, D. H.

    2004-08-01

    The final goal of this project is to develop an integrated I and C systems, and through this project the localized equipment and systems being developed should secure the safety, the reliability, their applicability and technical competitiveness. As well, the technical interfaces among sub-projects should be maintained for integration. The results of this project are as following ; 1. Development of an integrated I and C system architecture: Development of the design concepts for KNICS and the design requirements for each I and C system, Development of the design requirements of control systems based on DCS, Design of the communication systems, Design of the interface signals among systems and analysis of traffic load for networks, Conceptual design of measuring and monitoring systems, Review of the structure of computer systems for information processing, Development of architectures for each system and KOICS 2. Technological integration and management of projects: Development of evaluation criteria for DCS and network systems, Evaluation of the DCS prototype, Design review of KNICS protection system, Review of the functions and design requirements of I and C systems in NPP, Analysis of the I and C system H/W in NPP and the APR1400 I and C system design, Review of the technology criteria and the regulatory trend for licensing issues, Extracting items for preparing the technical description of I and C systems, a part of proposal to invitation to bid (ITB), Planning for KNICS to be of practical use The results of this project will be applied as design bases during the development of 2nd phase KNICS. As well it is expected that the results of this project will be finally applied for the technical self-reliance of component design and manufacturing of NPP I and C systems

  5. Advantages and Limitations of Integrated Management System: the Theoretical Viewpoint

    Directory of Open Access Journals (Sweden)

    Agota Giedrė Raišienė

    2011-08-01

    management systems implementation studies in Lithuanian scientific literature. That hinders the possibility to frame specific recommendations to the practicians in Lithuania.Practical implications and value. In the contemporary world, coordination and supervision of management systems is a complex aim, which needs constant redesigning and innovations; organizations are challenged to optimize their management constantly. One of potentialities can be implementing an integrated management system. Traditionally, it consists of the quality management, employees’ health and safety management, social responsibility management and environmental protection management migration to one management system. As there is no international standard, that would submit unambiguous recommendations about ensuring the management system integration, every organization copes with this assignment on it‘s own. The paper gives value both to managers and to scientists who are interested in advantages and limitations of integrated management systems in general because of a generalized systemic approach to the research issue.

  6. Integral consideration of integrated management systems

    International Nuclear Information System (INIS)

    Frauenknecht, Stefan; Schmitz, Hans

    2010-01-01

    Aim of the project for the NPPs Kruemmel and Brunsbuettel (Vattenfall) is the integral view of the business process as basis for the implementation and operation of management systems in the domains quality, safety and environment. The authors describe the integral view of the business processes in the frame of integrated management systems with the focus nuclear safety, lessons learned in the past, the concept of a process-based controlling system and experiences from the practical realization.

  7. Material protection control and accounting program activities at the Urals electrochemical integrated plant

    International Nuclear Information System (INIS)

    McAllister, S.

    1997-01-01

    The Urals Electrochemical Integrated Plant (UEIP) is the Russian Federation's largest uranium enrichment plant and one of three sites in Russia blending high enriched uranium (HEU) into commercial grade low enriched uranium. UEIP is located approximately 70 km north of Yekaterinburg in the closed city of Novouralsk (formerly Sverdlovsk- 44). DOE's MPC ampersand A program first met with UEIP in June of 1996, however because of some contractual issues the work did not start until September of 1997. The six national laboratories participating in DOE's Material Protection Control and Accounting program are cooperating with UEIP to enhance the capabilities of the physical protection, access control, and nuclear material control and accounting systems. The MPC ampersand A work at UEIP is expected to be completed during fiscal year 2001

  8. Selectivity of power system protections at power swings in power system

    Directory of Open Access Journals (Sweden)

    Jan Machowski

    2012-12-01

    Full Text Available The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.

  9. Let the IRIS Bloom:Regrowing the integrated risk information system (IRIS) of the U.S. Environmental Protection Agency.

    Science.gov (United States)

    Dourson, Michael L

    2018-05-03

    The Integrated Risk Information System (IRIS) of the U.S. Environmental Protection Agency (EPA) has an important role in protecting public health. Originally it provided a single database listing official risk values equally valid for all Agency offices, and was an important tool for risk assessment communication across EPA. Started in 1986, IRIS achieved full standing in 1990 when it listed 500 risk values, the effort of two senior EPA groups over 5 years of monthly face-to-face meetings, to assess combined risk data from multiple Agency offices. Those groups were disbanded in 1995, and the lack of continuing face-to-face meetings meant that IRIS became no longer EPA's comprehensive database of risk values or their latest evaluations. As a remedy, a work group of the Agency's senior scientists should be re-established to evaluate new risks and to update older ones. Risk values to be reviewed would come from the same EPA offices now developing such information on their own. Still, this senior group would have the final authority on posting a risk value in IRIS, independently of individual EPA offices. This approach could also lay the groundwork for an all-government IRIS database, especially needed as more government Agencies, industries and non-governmental organizations are addressing evolving risk characterizations. Copyright © 2018. Published by Elsevier Inc.

  10. Research on effectiveness assessment programs for physical protection system

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu [Korea Institute of Nuclear Non-proliferation and Control, Daejeon (Korea, Republic of)

    2015-05-15

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT.

  11. Research on effectiveness assessment programs for physical protection system

    International Nuclear Information System (INIS)

    Seo, Janghoon; Yoo, Hosik; Ham, Taekyu

    2015-01-01

    PPS (Physical Protection System) is an integrated set of procedures, installation and human resources to protect valuable assets from physical attack of potential adversaries. Since nuclear facilities or radioactive materials can be attractive targets for terrorists, PPS should be installed and maintained throughout the entire lifecycle of nuclear energy systems. One of key ingredients for effective protection is a reliable assessment procedure of the PPS capability. Due to complexity of possible threat categories and pathways, several pathway analysis programs have been developed to ease analysis or visualization. ASSESS using ASD approach runs fast and adopts a relatively simple modeling process for facility elements. But uncertainty due to assumptions used in modeling might complicate the interpretation of results. On the other hand, 2D pathway program such as TESS can utilize more self-consistent detection probability and delay time since actual pathway on 2D map is available. Also, this pathway visualization helps users understand analysis result more intuitively. But, in general, 2D pathway programs require strong computational power and careful optimization. Another possible difference between two approaches is response force deployment and RFT

  12. High-temperature gas-cooled reactor steam-cycle/cogeneration lead plant. Plant Protection and Instrumentation System design description

    International Nuclear Information System (INIS)

    1983-01-01

    The Plant Protection and Instrumentation System provides plant safety system sense and command features, actuation of plant safety system execute features, preventive features which maintain safety system integrity, and safety-related instrumentation which monitors the plant and its safety systems. The primary function of the Plant Protection and Instrumentation system is to sense plant process variables to detect abnormal plant conditions and to provide input to actuation devices directly controlling equipment required to mitigate the consequences of design basis events to protect the public health and safety. The secondary functions of the Plant Protection and Instrumentation System are to provide plant preventive features, sybsystems that monitor plant safety systems status, subsystems that monitor the plant under normal operating and accident conditions, safety-related controls which allow control of reactor shutdown and cooling from a remote shutdown area

  13. Reactor protection and shut-down system

    International Nuclear Information System (INIS)

    Klar

    1980-01-01

    The reactor protection system being a part of the reactor safety system. The requirements on the reactor protection system are: high safety with regard to signal processing, high availability, self-reporting of faults etc. The functional sections of the reactor protection system are the analog section, the logic section and the generating of output signals. Description of the operation characteristics and of the extension of function. (orig.)

  14. Conducting an inspection of protection program operations

    International Nuclear Information System (INIS)

    Brown, S.; Howell, J.

    1987-01-01

    Protection Program Operations (PPO) encompasses the entire physical security program at a facility, including security construction and equipment, procedures, forces, management and supervision, and the integration of these elements into a total system. PPO subtopics are Physical Security Systems (PSS), Protection Forces (PF), and System Performance Tests (SPT). PSS assesses those security elements designed to protect security interests, and include sensors, surveillance devices, systems for transmission and integration of alarm and assessment information, barriers, lighting, etc. PF assesses the management, training, equipment and facilities, and skills and knowledge of the protective force. SPT includes Force-on-Force, Emergency Management Performance Test, and Limited Scope Performance Tests

  15. Safety Evaluation of Full Digital Plant Protection System of Shin-Kori 3 and 4 in Korea

    International Nuclear Information System (INIS)

    Koh, J. S.; Kim, D. I.; Jeong, C. H.; Park, H. S.; Ji, S. H.; Kang, Y. D.; Park, G. Y.

    2009-01-01

    Keeping pace with the emerging trend of digital computer technologies, KHNP has utilized full digital plant protection system into the design of I and C systems at SKN 3 and 4. This paper presents safety review activities and results related to digital plant protection systems during the licensing of construction permit for the Shin-Kori 3 and 4(SKN 3 and 4) in Korea. The major licensing issues regarding the digital systems were software quality and cyber security during planning stage, system integrity with fail-safe design, EMI equipment qualification of digital systems, FPGA qualification and communication independence between safety and non-safety System. This paper addresses our approach to evaluate full digital protection systems with revised safety review guidelines and the resulting discussion to resolve the licensing issues

  16. Integrated security system definition

    International Nuclear Information System (INIS)

    Campbell, G.K.; Hall, J.R. II

    1985-01-01

    The objectives of an integrated security system are to detect intruders and unauthorized activities with a high degree of reliability and the to deter and delay them until effective response/engagement can be accomplished. Definition of an effective integrated security system requires proper application of a system engineering methodology. This paper summarizes a methodology and describes its application to the problem of integrated security system definition. This process includes requirements identification and analysis, allocation of identified system requirements to the subsystem level and provides a basis for identification of synergistic subsystem elements and for synthesis into an integrated system. The paper discusses how this is accomplished, emphasizing at each step how system integration and subsystem synergism is considered. The paper concludes with the product of the process: implementation of an integrated security system

  17. A summary of impacts of wind power integration on power system small-signal stability

    Science.gov (United States)

    Yan, Lei; Wang, Kewen

    2017-05-01

    Wind power has been increasingly integrated into power systems over the last few decades because of the global energy crisis and the pressure on environmental protection, and the stability of the system connected with wind power is becoming more prominent. This paper summaries the research status, achievements as well as deficiencies of the research on the impact of wind power integration on power system small-signal stability. In the end, the further research needed are discussed.

  18. Data fusion concept in multispectral system for perimeter protection of stationary and moving objects

    Science.gov (United States)

    Ciurapiński, Wieslaw; Dulski, Rafal; Kastek, Mariusz; Szustakowski, Mieczyslaw; Bieszczad, Grzegorz; Życzkowski, Marek; Trzaskawka, Piotr; Piszczek, Marek

    2009-09-01

    The paper presents the concept of multispectral protection system for perimeter protection for stationary and moving objects. The system consists of active ground radar, thermal and visible cameras. The radar allows the system to locate potential intruders and to control an observation area for system cameras. The multisensor construction of the system ensures significant improvement of detection probability of intruder and reduction of false alarms. A final decision from system is worked out using image data. The method of data fusion used in the system has been presented. The system is working under control of FLIR Nexus system. The Nexus offers complete technology and components to create network-based, high-end integrated systems for security and surveillance applications. Based on unique "plug and play" architecture, system provides unmatched flexibility and simplistic integration of sensors and devices in TCP/IP networks. Using a graphical user interface it is possible to control sensors and monitor streaming video and other data over the network, visualize the results of data fusion process and obtain detailed information about detected intruders over a digital map. System provides high-level applications and operator workload reduction with features such as sensor to sensor cueing from detection devices, automatic e-mail notification and alarm triggering.

  19. Physical protection system using activated barriers

    International Nuclear Information System (INIS)

    Timm, R.E.; Zinneman, T.E.; Haumann, J.R.; Flaugher, H.A.; Reigle, D.L.

    1984-03-01

    The Argonne National Laboratory has recently installed an activated barrier, the Access Denial System, to upgrade its security. The technology of this system was developed in the late 70's by Sandia National Laboratory-Albuquerque. The Argonne National Laboratory is the first Department of Energy facility to use this device. Recent advancements in electronic components provide the total system support that makes the use of an activated barrier viable and desirable. The premise of an activated barrier is that it is deployed after a positive detection of an adversary is made and before the adversary can penetrate vital area. To accomplish this detection, sophisticated alarms, assessment, and communications must be integrated into a system that permits a security inspector to make a positive evaluation and to activate the barrier. The alarm sensor locations are selected to provide protection in depth. Closed circuit television is used with components that permit multiple video frames to be stored for automated, priority-based playback to the security inspector. Further, algorithms permit look-ahead surveillance of vital areas so that the security inspector can activate the access denial system in a timely manner and not be restricted to following the adversaries' penetration path(s)

  20. Regulatory control of physical protection systems

    International Nuclear Information System (INIS)

    Rajdeep; Mayya, Y.S.

    2017-01-01

    The safety of facilities in BARC is under the regulatory oversight of BSC. The security architecture for these facilities incorporates multiple layers of Physical Protection Systems. The demands of safety may sometimes conflict with the needs of security. Realizing the need to identify these interfaces and extend the regulatory coverage to Physical Protection Systems, a Standing Committee named Physical Protection System Review Committee (PPSRC) has been constituted as a 2"n"d tier entity of BSC. PPSRC includes experts from various domains concerned with nuclear security, viz. physical protection systems, cyber security, radiation safety, security operations, technical services and security administration

  1. Fire protection system management in nuclear facilities: strengthening factor of integrated management system - a case study; Gestao de sistema de protecao contra incendio em instalacoes nucleares: fator de fortalecimento do sistema de gestao integrada - um estudo de caso

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joao Regis dos

    2005-07-01

    The present study investigated and analyzed the importance of a system of integrated safety manage, environment and health in a nuclear installation, having as perspective, the fire protection manage. The inquiry was made using a qualitative research involving a case study, where the considered environment was the Reconversion and UO{sub 2} Plant of the Industrias Nucleares do Brasil (INB), located in Resende, Rio de Janeiro and the studied population, the managers and the staff directly involved with the aspects related to the safety of the industrial complex of the related company. The motivation for the research was the search of a bigger interaction of the questions related to the safety, environment and health in the nuclear industry having, as axle of the investigation, the fire protection. As a result, it was observed that in a nuclear installation, although dealing with diversified safety processes, integration is possible and necessary, since there are more reasons for integration than otherwise. (author)

  2. Protecting Financial Market Integrity: Roles and Responsibilities of Auditors

    NARCIS (Netherlands)

    P.A.M. Diekman (Peter)

    2008-01-01

    textabstractWaarom heeft u nog vertrouwen in een bank? En waarom vertrouwt u uw geld nog toe aan banken? Deze vragen staan centraal in de oratie ‘Protecting Financial Market Integrity. Roles and Responsibilities of Auditors' van prof.dr. Peter A.M. Diekman RA. Hij stelt dat zowel de intern als de

  3. Distributed Supervisory Protection Interlock System

    International Nuclear Information System (INIS)

    Walz, H.V.; Agostini, R.C.; Barker, L.; Cherkassky, R.; Constant, T.; Matheson, R.

    1989-03-01

    The Distributed Supervisory Protection Interlock System, DSPI, is under development at the Stanford Linear Accelerator Center for requirements in the areas of personnel protection, beam containment and equipment protection interlocks. The DSPI system, distributed over the application site, consists of segments with microprocessor-based controller and I/O modules, local area networks for communication, and a global supervisor computer. Segments are implemented with commercially available controller and I/O modules arranged in local interlock clusters, and associated software. Segments provide local interlock data acquisition, processing and control. Local area networks provide the communication backbone between segments and a global supervisor processor. The supervisor processor monitors the overall system, reports detail status and provides human interfaces. Details of an R and D test system, which will implement the requirements for personnel protection of 4 typical linear accelerator sectors, will be described. 4 refs., 2 figs

  4. A Collaborative Analysis Tool for Integrated Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald; Landrum, Brian

    2000-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. Then there is a transition to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scramjet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance. To adequately determine the performance of the engine/vehicle, the Hypersonic Flight Inlet Model (HYFIM) module was designed to interface with the RBCC

  5. Power system protection 2 systems and methods

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  6. Wind turbine with lightning protection system

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a wind turbine comprising a lightning protection system comprising a waveguide interconnecting a communication device and a signal-carrying structure. In other aspects, the present invention relates to the use of a waveguide in a lightning protection system...... of a wind turbine, a power splitter and its use in a lightning protection system of a wind turbine....

  7. An integrated low-voltage rated HTS DC power system with multifunctions to suit smart grids

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian Xun, E-mail: jxjin@uestc.edu.cn [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Center of Applied Superconductivity and Electrical Engineering, School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731 (China); Chen, Xiao Yuan [School of Engineering, Sichuan Normal University, Chengdu 610101 (China); Qu, Ronghai; Fang, Hai Yang [School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Xin, Ying [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2015-03-15

    Highlights: • A novel LVDC HTS power transmission network is presented. • An integrated power system is achieved by using HTS DC cable and SMES. • DC superconducting cable is verified to achieve self-acting fault current limitation. • SMES is verified to achieve fast-response buffering effect under a power fluctuation. • SMES is verified to achieve favorable load voltage protection effect under a fault. - Abstract: A low-voltage rated DC power transmission network integrated with superconducting cables (SCs) and superconducting magnetic energy storage (SMES) devices has been studied with analytic results presented. In addition to the properties of loss-less and high current transportation capacity, the effectively integrated system is formed with a self-acting fault current limitation feature of the SC and a buffering effect of the SMES to power fluctuations. The results obtained show that the integrated system can achieve high-quality power transmission under common power fluctuation conditions with an advanced self-protection feature under short circuit conditions, which is identified to suit especially the smart grid applications.

  8. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  9. Design Of Photovoltaic Powered Cathodic Protection System

    Directory of Open Access Journals (Sweden)

    Golina Samir Adly

    2017-07-01

    Full Text Available The corrosion caused by chemical reaction between metallic structures and surrounding mediums such as soil or water .the CP cathodic protection system is used to protect metallic structure against corrosion. Cathodic protection CP used to minimize corrosion by utilizing an external source of electrical current which forces the entire structure to become a cathode. There are two Types of cathodic protection system Galvanic current Impressed current.the Galvanic current is called a sacrificial anode is connected to the protected structure cathode through a DC power supply. In Galvanic current system a current passes from the sacrificing anode to the protected structure .the sacrificial anode is corroded rather than causing the protected structure corrosion .protected structure requires a constant current to stop the corrosion which determined by area structure metal and the surrounding medium. The rains humidity are decrease soil resistivity and increase the DC current .The corrosion and over protection resulting from increase in the DC current is harmful for the metallic structure. This problem can be solved by conventional cathodic protection system by manual adjustment of DC voltage periodically to obtain a constant current .the manual adjustment of DC voltage depends on experience of the technician and using the accuracy of the measuring equipment. The errors of measuring current depend on error from the technician or error from the measuring equipment. the corrosion of structure may occur when the interval between two successive adjustment is long .An automatically regulated cathodic protection system is used to overcome problems from conventional cathodic protection system .the regulated cathodic protection system adjust the DC voltage of the system automatically when it senses the variations of surrounding medium resistivity so the DC current is constant at the required level.

  10. Plutonium Protection System (PPS). Volume 2. Hardware description. Final report

    International Nuclear Information System (INIS)

    Miyoshi, D.S.

    1979-05-01

    The Plutonium Protection System (PPS) is an integrated safeguards system developed by Sandia Laboratories for the Department of Energy, Office of Safeguards and Security. The system is designed to demonstrate and test concepts for the improved safeguarding of plutonium. Volume 2 of the PPS final report describes the hardware elements of the system. The major areas containing hardware elements are the vault, where plutonium is stored, the packaging room, where plutonium is packaged into Container Modules, the Security Operations Center, which controls movement of personnel, the Material Accountability Center, which maintains the system data base, and the Material Operations Center, which monitors the operating procedures in the system. References are made to documents in which details of the hardware items can be found

  11. Integration of a browser based operator manual in the system environment of a process computer system; Integration eines browserbasierten Betriebshandbuchs in die Systemumgebung einer Prozessrechneranlage

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Andreas [Westinghouse Electric Germany GmbH (Germany); Erfle, Robert [DOSCO GmbH, Heidelberg (Germany); Feinkohl, Dirk [E.ON Kernkraft GmbH (Germany). Kernkraftwerk Unterweser

    2012-11-01

    The integration of a browser based operator manual in the system environment of a process computer system is an optimization of the operating procedure in the control room and a safety enhancement due to faster and error-free access to the manual contents. Several requirements by the authorities have to be fulfilled: the operating manual has to be available as hard copy, the format has to be true to original, protection against manipulation has to be provided, the manual content of the browser-based version and the hard copy have to identical, and the display presentation has to be consistent with ergonomic principals. The integration of the on-line manual in the surveillance process computer system provides the operator with the relevant comments to the surveillance signal. The described integration of the on-line manual is an optimization of the operator's everyday job with respect to ergonomics and safety (human performance).

  12. Control and management of distribution system with integrated DERs via IEC 61850 based communication

    Directory of Open Access Journals (Sweden)

    Ikbal Ali

    2017-06-01

    Full Text Available Distributed Energy Resources (DERs are being increasingly integrated in the distribution systems and resulting in complex power flow scenarios. In such cases, effective control, management and protection of distribution systems becomes highly challenging. Standardized and interoperable communication in distribution systems has the potential to deal with such challenges to achieve higher energy efficiency and reliability. Ed. 2 of IEC 61850 standards, for utility automation, standardizing the exchange of data among different substations, DERs, control centers, PMUs and PDCs. This paper demonstrates the modelling of information and services needed for control, management and protection of distribution systems with integrated DERs. This paper has used IP tunnels and/or mapping over IP layer for transferring IEC 61850 messages, such as sample values (SVs and GOOSE (Generic Object Oriented Substation Event, over distribution system Wide Area Network (WAN. Finally performance of the proposed communication configurations for different applications is analyzed by calculating End-to-End (ETE delay, throughput and jitter.

  13. IEC 61850 based refurbishment strategies for protection and automation systems

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    Electric utilities are currently facing the challenge of refurbishing aging transmission networks and power system infrastructure at a time of severe economic, environmental and competitive constraints. This paper addressed the issue of an appropriate approach to retrofit the hardware and software of substation secondary systems, and how IEC standards could be used to set up a long term strategy. The first part of the paper considered an asset management strategy for refurbishing substation secondary systems, while the second part of the paper addressed the strategies for refurbishing existing power plants. The final section of the paper analyzed refurbishment strategies designed to protect power distribution systems. The impact of IEC 61850 and how legacy devices can be integrated in substation automation systems were discussed. It was concluded that new SCADA systems are needed to handle new technology. Additional features like remote control, remote settings, remote disturbance records analysis and remote maintenance are also needed to properly operate the power system. The value of preventive maintenance using remote monitoring systems to determine the status of all the digital electronic devices installed in substation was also discussed. IEC 61850 offers several opportunities to improve grid operation and control. It supports interoperability between protective relays and control devices from different manufacturers in the substation, which is required in order to achieve substation level interlocking, protection and control functions and improve the efficiency of microprocessor based relays applications. This technology has now passed the initial stage of implementation and several projects are underway worldwide. 13 figs.

  14. Temporary physical protection systems

    International Nuclear Information System (INIS)

    Williams, J.D.; Gangel, D.J.; Madsen, R.W.

    1991-01-01

    Terrorism and other aspects of world political instability have created a high demand for temporary physical protection systems within the nuclear materials management community. They can be used when vehicles carrying important assets are away from their permanent fixed site location, around areas where experiments are being temporarily conducted, around construction areas and one portions of a fixed site physical security system which is temporarily inoperable. Physical security systems can be grouped into four categories: tactical, portable, semi-permanent, and fixed. The resources and experience gained at Sandia National Laboratories in over forty years of developing and implementing security systems for protecting nuclear weapons and fixed nuclear facilities is now being applied to temporary physical security systems. This paper emphasizes temporary physical security systems and their component parts that are presently available and identify additional system-subsystem objectives, requirements, and concepts

  15. Machine protection system algorithm compiler and simulator

    International Nuclear Information System (INIS)

    White, G.R.; Sherwin, G.

    1993-01-01

    The Machine Protection System (MPS) component of the SLC's beam selection system, in which integrated current is continuously monitored and limited to safe levels through careful selection and feedback of the beam repetition rate, is described elsewhere in these proceedings. The novel decision making mechanism by which that system can evaluate open-quotes safe levelsclose quotes, and choose an appropriate repetition rate in real-time, is described here. The algorithm that this mechanism uses to make its decision is written in test files and expressed in states of the accelerator and its devices, one file per accelerator region. Before being used, a file is open-quotes compiledclose quotes to a binary format which can be easily processed as a forward-chaining decision tree. It is processed by distributed microcomputers local to the accelerator regions. A parent algorithm evaluates all results, and reports directly to the beam control microprocessor. Operators can test new algorithms, or changes they make to them, with an online graphical MPS simulator

  16. Identity management and witness protection system

    OpenAIRE

    Paunović, Saša; Starčević, Dušan; Nešić, Lazar

    2013-01-01

    The protection of participants in criminal proceedings is one of the most important tools for prosecution of war crimes and organized crime cases. The paper presents the basic characteristics and the importance of implementing the Program of protection in criminal proceedings, with emphasis on the protection system and management of identity. Special attention was paid to challenges facing the protection system in criminal proceedings and the management of identities, which are caused by the ...

  17. Searching for integrable systems

    International Nuclear Information System (INIS)

    Cary, J.R.

    1984-01-01

    Lack of integrability leads to undesirable consequences in a number of physical systems. The lack of integrability of the magnetic field leads to enhanced particle transport in stellarators and tokamaks with tearing-mode turbulence. Limitations of the luminosity of colliding beams may be due to the onset of stochasticity. Enhanced radial transport in mirror machines caused by the lack of integrability and/or the presence of resonances may be a significant problem in future devices. To improve such systems one needs a systematic method for finding integrable systems. Of course, it is easy to find integrable systems if no restrictions are imposed; textbooks are full of such examples. The problem is to find integrable systems given a set of constraints. An example of this type of problem is that of finding integrable vacuum magnetic fields with rotational transform. The solution to this problem is relevant to the magnetic-confinement program

  18. 78 FR 77574 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-12-24

    ... commissioning of power system protection systems.\\55\\ NERC commits in its Comments to keep the Commission... commissioning of power system protection systems.\\62\\ As explained in the NOPR, our concern is with a protection... protection system, ``resulting in line relays being placed in service with the incorrect transformer ratio...

  19. THE IMPLEMENTATION OF THE INTEGRATED MANAGEMENT SYSTEMS IN TOURIST PENSION

    Directory of Open Access Journals (Sweden)

    Elena G. CONDREA

    2014-04-01

    Full Text Available We can say that you cannot maintain yourself on the current market of rural tourism operators unless you provide customers with quality products and services, prepared foods safe for consumption, and, not least, if you do not prove you are concerned with ensuring a healthy and clean environment, environmental protection. In this paper we intend to present some aspects of implementing an integrated management system of quality - food security - the average level of tourist pension, and highlight the benefits brought by this ongoing process to the respective operators in rural tourism. To this end, we studied the standards, references available in this area, and documents produced within guesthouses with the implementation of various management systems components of an integrated quality - environment - food security management system.

  20. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  1. Proceedings of the First European workshop on the ethical dimensions of the radiological protection system

    International Nuclear Information System (INIS)

    2013-12-01

    The System of radiological protection develops gradually integrating advances in knowledge about the effects of radiation, the feedback from its practical implementation in all relevant domains, as well as the evolution of the ethical and social values that shape community life in modern societies. Although there is a long tradition of ICRP to consider such values in the development of its Recommendations, there is a need to make them explicit. This should facilitate the understanding of the system for specialists and non-specialists in radiological protection and allow a renewed dialogue on its foundations, its objectives and rationality. It should also encourage the emergence of informed behaviours in society vis-a-vis radiations. In this perspective, ICRP has initiated a reflection in the recent years on the ethical dimensions of the radiological protection system. This reflection has highlighted the links between the fundamental principles of radiation protection (justification, optimization, limitation) and the theories of normative ethics. The recommendations of the Commission are designed to respect individual rights (deontological ethics), to promote the collective interest (utilitarian ethics) and favour vigilance and equity (virtue ethics). This reflection it also identified the interest for the analysis of the radiological protection system to distinguish the ethical values defining the standards by which action should be taken, the ethical procedures for integrating these values in decision making and in the implementation of the decisions, and the ethical behaviour corresponding to the values that are supposed to guide the conduct of the various actors. Because the radiation protection system is intended to be international, the reflection also emphasized the importance of promoting through the Recommendations, values common to different cultures such as autonomy, non-maleficence, beneficence and justice. The objective of the Workshop is to explore

  2. CONCERT. ''European joint programme for the integration of radiation protection research''

    International Nuclear Information System (INIS)

    Schmitt-Hannig, A.; Birschwilks, M.; Jung, T.

    2016-01-01

    CONCERT is a joint project of the EU and its member states which assume joint financing: Over the next five years the largest European radiation protection programme so far will have available about 28 Million Euros for research and integrative measures, whereby the European Commission will bear 70 per cent of the costs. Integrative measures include, among others, targeted vocational education and training of junior researchers in radiation protection, better access to research and irradiation facilities for scientists, as well as a stronger connection of universities and research centres in radiation protection research.

  3. Smart cathodic protection systems

    NARCIS (Netherlands)

    Polder, R.B.; Leggedoor, J.; Schuten, G.; Sajna, S.; Kranjc, A.

    2010-01-01

    Cathodic protection delivers corrosion protection in concrete structures exposed to aggressive environments, e.g. in de-icing salt and marine climates. Working lives of a large number of CP systems are at least more than 13 years and probably more than 25 years, provided a minimum level of

  4. Integration of a browser based operator manual in the system environment of a process computer system

    International Nuclear Information System (INIS)

    Weber, Andreas; Erfle, Robert; Feinkohl, Dirk

    2012-01-01

    The integration of a browser based operator manual in the system environment of a process computer system is an optimization of the operating procedure in the control room and a safety enhancement due to faster and error-free access to the manual contents. Several requirements by the authorities have to be fulfilled: the operating manual has to be available as hard copy, the format has to be true to original, protection against manipulation has to be provided, the manual content of the browser-based version and the hard copy have to identical, and the display presentation has to be consistent with ergonomic principals. The integration of the on-line manual in the surveillance process computer system provides the operator with the relevant comments to the surveillance signal. The described integration of the on-line manual is an optimization of the operator's everyday job with respect to ergonomics and safety (human performance).

  5. Integrated input protection against discharges for Micro Pattern Gas Detectors readout ASICs

    International Nuclear Information System (INIS)

    Fiutowski, T.; Dąbrowski, W.; Koperny, S.; Wiącek, P.

    2017-01-01

    Immunity against possible random discharges inside active detector volume of MPGDs is one of the key aspects that should be addressed in the design of the front-end electronics. This issue becomes particularly critical for systems with high channel counts and high density readout employing the front-end electronics built as multichannel ASICs implemented in modern CMOS technologies, for which the breakdown voltages are in the range of a few Volts. The paper presents the design of various input protection structures integrated in the ASIC manufactured in a 350 nm CMOS process and test results using an electrical circuit to mimic discharges in the detectors.

  6. [Artificial intelligence] AI for protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, R.; Johns, A.

    1997-12-31

    The reliable operation of large power systems with small stability margins is highly dependent on control systems and protection devices. Progress in the field of microprocessor systems and demanding requirements in respect of the performance of protective relays are the reasons for digital device applications to power system protection. The superiority of numeric protection over its analogue alternatives is attributed to such factors as accurate extraction of the fundamental voltage and current components through filtering, functional benefits resulting from multi-processor design and extensive self-monitoring, etc. However, all these reasons have not led to a major impact on speed, sensitivity and selectivity of primary protective relays, and the gains are only marginal; this is so because conventional digital relays still rely on deterministic signal models and a heuristic approach for decision making, so that only a fraction of the information contained within voltage and current signals as well as knowledge about the plant to be protected is used. The performance of digital relays may be substantially improved if the decision making is based on elements of artificial intelligence (AI). (Author)

  7. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  8. Selective protection. Selektivschutz

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    TC 2, ''Transmission and distribution of electrical energy'', held its meeting on selective protection on 16/17 March 1983 at Nuremberg. The main reason for the development of computerized protective systems is their ability to solve a wide range of tasks using only a few, high-integrated systems, i.e. on the software side instead of the hardware side. At the meeting, experts from industrial companies and public utilities reviewed the status and trends of protective systems engineering. Scientific studies and operating experience were presented. Separate abstracts were prepared for 2 papers in this conference proceedings volume.

  9. Reactor protection system. Revision 1

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Vincent, D.R.; Lesniak, L.M.

    1975-04-01

    The reactor protection system-II (RPS-II) designed for use on Babcock and Wilcox 145- and 205-fuel assembly pressurized water reactors is described. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W. (U.S.)

  10. INTEGRATED MANAGEMENT SYSTEMS IN LOCAL PUBLIC ENTERPRIZE FOR PRODUCTION, DISTRIBUTION AND CLEANING OF WASTED WATER

    Directory of Open Access Journals (Sweden)

    Slavko Arsovski

    2007-06-01

    Full Text Available Appearance of large number of management systems, with different and sometimes divergent demands, needs reconsideration of their implementation strategies and their integration in one integrated management system (IMS. So defined IMS would be designed and implemented in different areas. In this paper is presented basic concept of integration of partical management systems in areas of quality (ISO 9001, environmental protection (ISO 14001, occupational health (ISO 18001, food safety (ISO 22000 and accreditation of laboratories (ISO17025/ISO17020. As a pilot organization is choosed local public enterprise for production, supply and drain of water.

  11. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major US Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed in this paper. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. Finally, a list of measures is given for assessing overall physical protection system performance. (author)

  12. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1975-10-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely-activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. A list of measures is given for assessing overall physical protection system performance. (auth)

  13. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  14. Improved core protection calculator system algorithm

    International Nuclear Information System (INIS)

    Yoon, Tae Young; Park, Young Ho; In, Wang Kee; Bae, Jong Sik; Baeg, Seung Yeob

    2009-01-01

    Core Protection Calculator System (CPCS) is a digitized core protection system which provides core protection functions based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels which adapted a two out of four trip logic. CPCS algorithm improvement for the newly designed core protection calculator system, RCOPS (Reactor COre Protection System), is described in this paper. New features include the improvement of DNBR algorithm for thermal margin, the addition of pre trip alarm generation for auxiliary trip function, VOPT (Variable Over Power Trip) prevention during RPCS (Reactor Power Cutback System) actuation and the improvement of CEA (Control Element Assembly) signal checking algorithm. To verify the improved CPCS algorithm, CPCS algorithm verification tests, 'Module Test' and 'Unit Test', would be performed on RCOPS single channel facility. It is expected that the improved CPCS algorithm will increase DNBR margin and enhance the plant availability by reducing unnecessary reactor trips

  15. Designing physical protection technology for insider protection

    International Nuclear Information System (INIS)

    Trujillo, A.A.; Waddoups, I.G.

    1986-01-01

    Since its inception, the nuclear industry has been engaged in providing protection against an insider threat. Although insider protection activities have been fairly successful in the past, present societal conditions require increased protection to further minimize the existence of an insider or the consequences of an insider-perpetrated incident. Integration of insider protection techniques into existing administrative and operational procedures has resulted in economic and operational impacts. Future increases in insider protection may result in even greater impacts, so we must proceed wisely as new approaches are developed. Increased emphasis on background investigations, security clearances, human reliability programs, security awareness activities, and the development of technology to address the insider threat are evidence of continuing concern in this area. Experience ranging from operational test and evaluation of developmental equipment to conceptual designs for new facilities has led to the development of general principles and conclusions for mitigating the insider threat while minimizing adverse impacts on site operations. Important principles include real-time monitoring of personnel and material and requiring that the physical protection and material control and accounting systems to be much more coordinated and integrated than in the past

  16. Integrated Monitoring System for Durability Assessment of Concrete Bridges

    Directory of Open Access Journals (Sweden)

    Cristian-Claudiu Comisu

    2005-01-01

    Full Text Available An ageing and deteriorating bridge stock presents the bridge owners with the growing challenge of maintaining the structures at a satisfactory level of safety, performance and aesthetic appearance within the allocated budgets. This task calls for optimized bridge management based on efficient methods of selecting technical and economical optimal maintenance and rehabilitation strategies. One of the crucial points in the assessment of the current condition and future development and performance. Selecting the optimal maintenance and rehabilitation strategy within the actual budget is a key point in bridge management for which an accurate assessment of performance and deterioration rate is necessary. For this assessment, the use of integrated monitoring system has several advantages compared to the traditional approach of scattered visual inspections combined with occasional on site testing with portable equipment and laboratory testing of collected samples. For this reason, attention is more focusing on the development of permanent integrated monitoring system for durability assessment of concrete bridges. It is estimated that with the implementation of such integrated monitoring systems, it should be possible to reduce the operating costs of inspections and maintenance by 25% and the operator of the structures will be able to take protective actions before damaging processes start. This paper indentifies the main bridge owner requirements to integrated monitoring systems and outlines how monitoring systems may be used for performance and deterioration rate assessment to establish a better basis for selecting the optimal maintenance and rehabilitation strategy.

  17. Availability analysis of supervised protective systems

    International Nuclear Information System (INIS)

    Kontoleon, N.; Kontoleon, J.M.; Chrysochoides, N.G.

    1975-01-01

    The behaviour in time of a nuclear reactor supervised protective system is modelled mathematically by a Markov process, continuous in time and with three discrete states. Failure and repair rates are assumed to be exponentially distributed. An analytical expression of system availability as a function of failure and repair rates as well as the inspection intervals and duration is derived. An optimization problem is then discussed in order to maximize system availability with respect to imposed cost constraints. Finally, an example of a supervised protective system with short inactive times is given, which may be found in many practical situations of modern protective systems. (author)

  18. The LHC quench protection system

    CERN Multimedia

    2009-01-01

    The new quench protection system (QPS) has the crucial roles of providing an early warning for any part of the superconducting coils and busbars that develop high resistance, as well as triggering the switch-off of the machine. Over 2000 new detectors will be installed around the LHC to make sure every busbar segment between magnets is monitored and protected. One of the major consolidation activities for the LHC is the addition of two new detectors to the quench protection system. A magnet quench occurs when part of the superconducting cable becomes normally-conducting. When the protection system detects an increased resistance the huge amount of energy stored in the magnet chains is safely extracted and ‘dumped’ into specially designed resistors. In the case of the main dipole chain, the stored energy in a single LHC sector is roughly the same as the kinetic energy of a passenger jet at cruising speed. The first new detector is designed to monitor the superconducting...

  19. Physical protection as the most important part of the national system of combating illicit trafficking

    International Nuclear Information System (INIS)

    Ivanov, P.; Kokhan, V.D.

    2001-01-01

    based on the Convention on Physical Protection, IAEA Guidelines and Recommendations on Physical Protection of Nuclear Materials and Nuclear Installations as well as 'Basic Safety Standards for Ionising Radiation', practical application of which facilitates the development of a national system for combating illicit trafficking of radioactive materials and sources of radiation. These documents will assist in creating basic national legislation. An integrated approach should be provided for the improvement of the System of Physical Protection. These are main provisions of the Concept of Integration of the System of Physical Protection with the System of Accountancy and Control of Nuclear Materials. Goals: earlier detection of theft; improve accuracy of accounts, strengthen objectives and integrity of control; ensure personnel's safety; reduce dependence on human factor; speed-up detection and retrieval of stolen or lost material. The system is based on: national norms and regulations for accountancy, control and physical protection of nuclear materials and installations; existing control and management structure for nuclear materials and nuclear installations; senior officials and companies responsible for organization and quality assurance regarding work on accountancy, control and physical protection; new principles of accountancy and control; methods for supervision of working procedures, response to any abnormal event; model of life circle of nuclear materials; zone classification of nuclear materials etc. Establishment of single integrated system for accountancy, control and physical protection will undoubtedly lead to handling illicit trafficking of nuclear materials more efficiently and to eliminating unauthorized distribution of nuclear materials

  20. Protected River. A new concept for conservation management of fluvial systems in Colombia

    International Nuclear Information System (INIS)

    Andrade; German I

    2011-01-01

    Based upon the concept of Ecological Integrity, relevant geophysical, bio- ecological and social attributes for river systems area identified. It is argued that current conservation and environmental management instruments in Colombia, do not take into account the identified IE attributes simultaneously. The concept of Protected River, PR, is then presented, as a necessary complement for conservation strategies. The PR concept would be defined for the maintenance of the attributes of EI in some representative river systems, as a part of the biodiversity conservation objectives within the Convention of Biological Diversity. Some attributes and indicators, and thresholds of undesired change are discussed. A typology for PR is proposed, following the international protected area management categories.

  1. A Cryptographic SoC for Robust Protection of Secret Keys in IPTV DRM Systems

    Science.gov (United States)

    Lee, Sanghan; Yang, Hae-Yong; Yeom, Yongjin; Park, Jongsik

    The security level of an internet protocol television (IPTV) digital right management (DRM) system ultimately relies on protection of secret keys. Well known devices for the key protection include smartcards and battery backup SRAMs (BB-SRAMs); however, these devices could be vulnerable to various physical attacks. In this paper, we propose a secure and cost-effective design of a cryptographic system on chip (SoC) that integrates the BB-SRAM with a cell-based design technique. The proposed SoC provides robust safeguard against the physical attacks, and satisfies high-speed and low-price requirements of IPTV set-top boxes. Our implementation results show that the maximum encryption rate of the SoC is 633Mb/s. In order to verify the data retention capabilities, we made a prototype chip using 0.18µm standard cell technology. The experimental results show that the integrated BB-SRAM can reliably retain data with a 1.4µA leakage current.

  2. Modernization of the physical protection system of IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Suzuki, F.F.

    2001-01-01

    the failure of one component of the physical protection system. Periodic maintenance of physical barriers, as fences, has been performed in order to keep the level of opponent retard. Portable VHP radios have been purchased to improve the security force communication, creating redundancy in the communication channels. The performance of the physical protection system depends largely on the security force personnel. For this reason, the modernization programme dedicates special attention to the training of those professionals. Emphasis is being given to the emergency procedures, because the personnel action in those cases was considered an important point. The specific training on radio communication is also being reinforced. Nowadays the committee is evaluating the creation of an integrated center of physical protection (ICPP), where the central alarm station will be installed. The ICPP will monitor continuously the intrusion sensors to be installed at the institute. In order to assess the alarms, TV cameras will be installed all around the fences of inner and protected areas. The ICPP will be equipped with redundant communication means with the security and response forces and with the high administration of the institution. (author)

  3. Power system protection 3 application

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  4. 46 CFR 153.460 - Fire protection systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Fire protection systems. 153.460 Section 153.460... Requirements for Flammable Or Combustible Cargoes § 153.460 Fire protection systems. Each self-propelled ship... protection system listed beside the cargo in Table 1 and described in the footnotes to Table 1. (b) The...

  5. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  6. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  7. Information protection playbook

    CERN Document Server

    Kane, Greg

    2013-01-01

    The primary goal of the Information Protection Playbook is to serve as a comprehensive resource for information protection (IP) professionals who must provide adequate information security at a reasonable cost. It emphasizes a holistic view of IP: one that protects the applications, systems, and networks that deliver business information from failures of confidentiality, integrity, availability, trust and accountability, and privacy. Using the guidelines provided in the Information Protection Playbook, security and information technology (IT) managers will learn how to

  8. Australia's proactive approach to radiation protection of the environment: how integrated is it with radiation protection of humans?

    Science.gov (United States)

    Hirth, G A; Grzechnik, M; Tinker, R; Larsson, C M

    2018-01-01

    Australia's regulatory framework has evolved over the past decade from the assumption that protection of humans implies protection of the environment to the situation now where radiological impacts on non-human species (wildlife) are considered in their own right. In an Australian context, there was a recognised need for specific national guidance on protection of non-human species, for which the uranium mining industry provides the major backdrop. National guidance supported by publications of the Australian Radiation Protection and Nuclear Safety Agency (Radiation Protection Series) provides clear and consistent advice to operators and regulators on protection of non-human species, including advice on specific assessment methods and models, and how these might be applied in an Australian context. These approaches and the supporting assessment tools provide a mechanism for industry to assess and demonstrate compliance with the environmental protection objectives of relevant legislation, and to meet stakeholder expectations that radiological protection of the environment is taken into consideration in accordance with international best practice. Experiences from the past 5-10 years, and examples of where the approach to radiation protection of the environment has been well integrated or presented some challenges will be discussed. Future challenges in addressing protection of the environment in existing exposure situations will also be discussed.

  9. Assessment and protection of esophageal mucosal integrity in patients with heartburn without esophagitis.

    Science.gov (United States)

    Woodland, Philip; Lee, Chung; Duraisamy, Yasotha; Duraysami, Yasotha; Farré, Ricard; Dettmar, Peter; Sifrim, Daniel

    2013-04-01

    Intact esophageal mucosal integrity is essential to prevent symptoms during gastroesophageal reflux events. Approximately 70% of patients with heartburn have macroscopically normal esophageal mucosa. In patients with heartburn, persistent functional impairment of esophageal mucosal barrier integrity may underlie remaining symptoms. Topical protection of a functionally vulnerable mucosa may be an attractive therapeutic strategy. We aimed to evaluate esophageal mucosal functional integrity in patients with heartburn without esophagitis, and test the feasibility of an alginate-based topical mucosal protection. Three distal esophageal biopsies were obtained from 22 patients with heartburn symptoms, and 22 control subjects. In mini-Ussing chambers, the change in transepithelial electrical resistance (TER) of biopsies when exposed to neutral, weakly acidic, and acidic solutions was measured. The experiment was repeated in a further 10 patients after pretreatment of biopsies with sodium alginate, viscous control, or liquid control "protectant" solutions. Biopsy exposure to neutral solution caused no change in TER. Exposure to weakly acidic and acidic solutions caused a greater reduction in TER in patients than in controls (weakly acid -7.2% (95% confidence interval (CI) -9.9 to -4.5) vs. 3.2% (-2.2 to 8.6), Pheartburn without esophagitis shows distinct vulnerability to acid and weakly acidic exposures. Experiments in vitro suggest that such vulnerable mucosa may be protected by application of an alginate-containing topical solution.

  10. Detection of impact damage on thermal protection systems using thin-film piezoelectric sensors for integrated structural health monitoring

    Science.gov (United States)

    Na, Jeong K.; Kuhr, Samuel J.; Jata, Kumar V.

    2008-03-01

    Thermal Protection Systems (TPS) can be subjected to impact damage during flight and/or during ground maintenance and/or repair. AFRL/RXLP is developing a reliable and robust on-board sensing/monitoring capability for next generation thermal protection systems to detect and assess impact damage. This study was focused on two classes of metallic thermal protection tiles to determine threshold for impact damage and develop sensing capability of the impacts. Sensors made of PVDF piezoelectric film were employed and tested to evaluate the detectability of impact signals and assess the onset or threshold of impact damage. Testing was performed over a range of impact energy levels, where the sensors were adhered to the back of the specimens. The PVDF signal levels were analyzed and compared to assess damage, where digital microscopy, visual inspection, and white light interferometry were used for damage verification. Based on the impact test results, an assessment of the impact damage thresholds for each type of metallic TPS system was made.

  11. CONCERT-'European Joint Programme for the Integration at Radiation Protection Research'; CONCERT-''European Joint Programme for the Integration at Radiation Protection Research''

    Energy Technology Data Exchange (ETDEWEB)

    Birschwilks, Mandy; Schmitt-Hannig, Annemarie [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). Internationale und Nationale Zusammenarbeit im Strahlenschutz; Jung, Thomas [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). Strahlenschutz und Gesundheit

    2016-08-01

    In 2009 the High Level Expert Group (HLEG) on low dose research recommended the development of a scientific platform for low dose radiation research. The foundation of MELODI (Multidisciplinary European Low Dose Initiative) occurred in 2010. In 2015 a new project on radiation protection research was established: CONCERT (European Joint Programme for the Integration at Radiation Protection Research). The aim is the coordination of the already existing scientific platforms MELODI (radiation effects and interactions), ALLIANCE (radioecology), NERIS (nuclear and radiological emergency protection) and EURADOS (radiation dosimetry). With CONCERT an efficient use of this infrastructure for research cooperation and transparency is intended.

  12. Verification and validation guidelines for high integrity systems. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D. [SoHaR, Inc., Beverly Hills, CA (United States)

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities.

  13. Verification and validation guidelines for high integrity systems. Volume 1

    International Nuclear Information System (INIS)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D.

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities

  14. TCR industrial system integration strategy

    CERN Document Server

    Bartolomé, R; Sollander, P; Martini, R; Vercoutter, B; Trebulle, M

    1999-01-01

    New turnkey data acquisition systems purchased from industry are being integrated into CERN's Technical Data Server. The short time available for system integration and the large amount of data per system require a standard and modular design. Four different integration layers have been defined in order to easily 'plug in' industrial systems. The first layer allows the integration of the equipment at the digital I/O port or fieldbus (Profibus-DP) level. A second layer permits the integration of PLCs (Siemens S5, S7 and Telemecanique); a third layer integrates equipment drivers. The fourth layer integrates turnkey mimic diagrams in the TCR operator console. The second and third layers use two new event-driven protocols based on TCP/IP. Using this structure, new systems are integrated in the data transmission chain, the layer at which they are integrated depending only on their integration capabilities.

  15. Integrated, digital experiment transient control and safety protection of an in-pile test

    International Nuclear Information System (INIS)

    Thomas, R.W.; Whitacre, R.F.; Klingler, W.B.

    1982-01-01

    The Sodium Loop Safety Facility experimental program has demonstrated that in-pile loop fuel failure transient tests can be digitally controlled and protected with reliability and precision. This was done in four nuclear experiments conducted in the Engineering Test Reactor operated by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Loop sodium flow and reactor power transients can be programmed to sponsor requirements and verified prior to the test. Each controller has redundancy, which reduces the effect of single failures occurring during test transients. Feedback and reject criteria are included in the reactor power control. Timed sequencing integrates the initiation of the controllers, programmed safety set-points, and other experiment actions (e.g., planned scram). Off-line and on-line testing is included. Loss-of-flow, loss-of-piping-integrity, boiling-window, transient-overpower, and local fault tests have been successfully run using this system

  16. Systems Integration | Photovoltaic Research | NREL

    Science.gov (United States)

    Integration Systems Integration The National Center for Photovoltaics (NCPV) at NREL provides grid integration support, system-level testing, and systems analysis for the Department of Energy's solar distributed grid integration projects supported by the SunShot Initiative. These projects address technical

  17. Supporting the material control and accountancy system with physical protection system features

    International Nuclear Information System (INIS)

    Miyoshi, D.S.; Olson, C.E.; Caskey, D.L.

    1984-01-01

    Most physical security functions can be accomplished by a range of alternative features. Careful design can provide comparable levels of security regardless of which option is chosen, albeit with possible differences in cost and efficiency. However, the effectiveness and especially the cost and efficiency of the material control and accounting system may be strongly influenced by the selection of a particular design approach to physical security. In this paper, a series of examples are cited to illustrate the effects that particular physical protection design choices may have. The examples have been chosen from several systems engineering projects at facilities within the DOE nuclear community. These examples are generalized, and a series of design principles are proposed for integrating physical security with material control and accounting by appropriate selection of alternative features. 2 references, 6 figures

  18. Supporting the material control and accountancy system with physical protection system features

    International Nuclear Information System (INIS)

    Miyoshi, D.S.; Caskey, D.L.; Olson, C.E.

    1984-01-01

    Most physical security functions can be accomplished by a range of alternative features. Careful design can provide comparable levels of security regardless of which option is chosen, albeit with possible differences in cost and efficiency. However, the effectiveness and especially the cost and efficiency of the material control and accounting system may be strongly influenced by the selection of a particular design approach to physical security. In this paper, a series of examples are cited to illustrate the effects that particular physical protection design choices may have. The examples have been chosen from several systems engineering projects at facilities within the DOE nuclear community. These examples are generalized, and a series of design principles are proposed for integrating physical security with MC and A by appropriate selection of alternative features

  19. Choosing the Right Systems Integration

    Directory of Open Access Journals (Sweden)

    Péči Matúš

    2014-12-01

    Full Text Available The paper examines systems integration and its main levels at higher levels of control. At present, the systems integration is one of the main aspects participating in the consolidation processes and financial flows of a company. Systems Integration is a complicated emotionconsuming process and it is often a problem to choose the right approach and level of integration. The research focused on four levels of integration, while each of them is characterized by specific conditions. At each level, there is a summary of recommendations and practical experience. The paper also discusses systems integration between the information and MES levels. The main part includes user-level integration where we describe an example of such integration. Finally, we list recommendations and also possible predictions of the systems integration as one of the important factors in the future.

  20. Error Correction and Calibration of a Sun Protection Measurement System for Textile Fabrics

    Energy Technology Data Exchange (ETDEWEB)

    Moss, A.R.L

    2000-07-01

    Clothing is increasingly being labelled with a Sun Protection Factor number which indicates the protection against sunburn provided by the textile fabric. This Factor is obtained by measuring the transmittance of samples of the fabric in the ultraviolet region (290-400 nm). The accuracy and hence the reliability of the label depends on the accuracy of the measurement. Some sun protection measurement systems quote a transmittance accuracy at 2%T of {+-} 1.5%T. This means a fabric classified under the Australian standard (AS/NZ 4399:1996) with an Ultraviolet Protection Factor (UPF) of 40 would have an uncertainty of +15 or -10. This would not allow classification to the nearest 5, and a UVR protection category of 'excellent protection' might in fact be only 'very good protection'. An accuracy of {+-}0.1%T is required to give a UPF uncertainty of {+-}2.5. The measurement system then does not contribute significantly to the error, and the problems are now limited to sample conditioning, position and consistency. A commercial sun protection measurement system has been developed by Camspec Ltd which used traceable neutral density filters and appropriate design to ensure high accuracy. The effects of small zero offsets are corrected and the effect of the reflectivity of the sample fabric on the integrating sphere efficiency is measured and corrected. Fabric orientation relative to the light patch is considered. Signal stability is ensured by means of a reference beam. Traceable filters also allow wavelength accuracy to be conveniently checked. (author)

  1. Error Correction and Calibration of a Sun Protection Measurement System for Textile Fabrics

    International Nuclear Information System (INIS)

    Moss, A.R.L.

    2000-01-01

    Clothing is increasingly being labelled with a Sun Protection Factor number which indicates the protection against sunburn provided by the textile fabric. This Factor is obtained by measuring the transmittance of samples of the fabric in the ultraviolet region (290-400 nm). The accuracy and hence the reliability of the label depends on the accuracy of the measurement. Some sun protection measurement systems quote a transmittance accuracy at 2%T of ± 1.5%T. This means a fabric classified under the Australian standard (AS/NZ 4399:1996) with an Ultraviolet Protection Factor (UPF) of 40 would have an uncertainty of +15 or -10. This would not allow classification to the nearest 5, and a UVR protection category of 'excellent protection' might in fact be only 'very good protection'. An accuracy of ±0.1%T is required to give a UPF uncertainty of ±2.5. The measurement system then does not contribute significantly to the error, and the problems are now limited to sample conditioning, position and consistency. A commercial sun protection measurement system has been developed by Camspec Ltd which used traceable neutral density filters and appropriate design to ensure high accuracy. The effects of small zero offsets are corrected and the effect of the reflectivity of the sample fabric on the integrating sphere efficiency is measured and corrected. Fabric orientation relative to the light patch is considered. Signal stability is ensured by means of a reference beam. Traceable filters also allow wavelength accuracy to be conveniently checked. (author)

  2. EMP protection procedure for electrical/electronic systems

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1976-01-01

    This paper presents a procedure for the protection engineer to follow in assessing a system with respect to its susceptibility to an electromagnetic pulse (EMP), and in determining whether the system requires protection. If the system is determined to be vulnerable to EMP, the procedure also indicates how to decide upon the most suitable protection scheme. The discussion centers on two flow charts, which illustrate the step-by-step procedure which utilizes the necessary ingredients of EMP protection engineering discussed in a previous paper. The description of the protection procedure is divided into two parts: the first dealing with issues on the macroscopic or large-scale system level, while the second is concerned with operations on the subsystem level or lower

  3. A Collaborative Analysis Tool for Thermal Protection Systems for Single Stage to Orbit Launch Vehicles

    Science.gov (United States)

    Alexander, Reginald; Stanley, Thomas Troy

    2001-01-01

    Presented is a design tool and process that connects several disciplines which are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to all other systems, as is the case with SSTO vehicles with air breathing propulsion, which is currently being studied by the National Aeronautics and Space Administration (NASA). In particular, the thermal protection system (TPS) is linked directly to almost every major system. The propulsion system pushes the vehicle to velocities on the order of 15 times the speed of sound in the atmosphere before pulling up to go to orbit which results in high temperatures on the external surfaces of the vehicle. Thermal protection systems to maintain the structural integrity of the vehicle must be able to mitigate the heat transfer to the structure and be lightweight. Herein lies the interdependency, in that as the vehicle's speed increases, the TPS requirements are increased. And as TPS masses increase the effect on the propulsion system and all other systems is compounded. To adequately calculate the TPS mass of this type of vehicle several engineering disciplines and analytical tools must be used preferably in an environment that data is easily transferred and multiple iterations are easily facilitated.

  4. 45 CFR 61.15 - How to dispute the accuracy of Healthcare Integrity and Protection Data Bank information.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false How to dispute the accuracy of Healthcare Integrity and Protection Data Bank information. 61.15 Section 61.15 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION HEALTHCARE INTEGRITY AND PROTECTION DATA BANK FOR FINAL ADVERSE...

  5. Prespacer processing and specific integration in a Type I-A CRISPR system

    Science.gov (United States)

    Rollie, Clare; Graham, Shirley; Rouillon, Christophe

    2018-01-01

    Abstract The CRISPR–Cas system for prokaryotic adaptive immunity provides RNA-mediated protection from viruses and mobile genetic elements. Adaptation is dependent on the Cas1 and Cas2 proteins along with varying accessory proteins. Here we analyse the process in Sulfolobus solfataricus, showing that while Cas1 and Cas2 catalyze spacer integration in vitro, host factors are required for specificity. Specific integration also requires at least 400 bp of the leader sequence, and is dependent on the presence of hydrolysable ATP, suggestive of an active process that may involve DNA remodelling. Specific spacer integration is associated with processing of prespacer 3′ ends in a PAM-dependent manner. This is reflected in PAM-dependent processing of prespacer 3′ ends in vitro in the presence of cell lysate or the Cas4 nuclease, in a reaction consistent with PAM-directed binding and protection of prespacer DNA. These results highlight the diverse interplay between CRISPR–Cas elements and host proteins across CRISPR types. PMID:29228332

  6. Sandia Laboratories plutonium protection system

    International Nuclear Information System (INIS)

    Bernard, E.A.; Miyoshi, D.S.; Gutierrez, F.D.

    1977-01-01

    Sandia Laboratories is developing an improved plutonium protection system (PPS) to demonstrate new concepts for enhancing special nuclear materials safeguards. PPS concepts include separation of functions, real-time item accountability and improved means for control of materials, activities and personnel access. Physical barriers and a secure communications network are designed into the system to offer greater protection against sabotage, diversion and theft attempts. Prototype systems are being constructed at Hanford, Washington and Albuquerque, New Mexico and will be subjected to a comprehensive testing and evaluation program

  7. The Diamond machine protection system

    International Nuclear Information System (INIS)

    Heron, M.T.; Lay, S.; Chernousko, Y.; Hamadyk, P.; Rotolo, N.

    2012-01-01

    The Diamond Light Source Machine Protection System (MPS) manages the hazards from high power photon beams and other hazards to ensure equipment protection on the booster synchrotron and storage ring. The system has a shutdown requirement, on a beam mis-steer of under 1 msec and has to manage in excess of a thousand interlocks. This is realised using a combination of bespoke hardware and programmable logic controllers. The MPS monitors a large number of interlock signals from diagnostics instrumentation, vacuum instrumentation, photon front ends and plant monitoring subsystems. Based on logic it can then remove the source of the energy to ensure protection of equipment. Depending on requirements, interlocks are managed on a Local or a Global basis. The Global system is structured as two layers, and supports fast- and slow-response-time interlock requirements. A Global MPS module takes the interlock permits for a given interlock circuit from each of the cells of the accelerator, and, subject to all interlocks being good, produces a permit to operate the source of energy: the RF amplifier for vessel protection and the PSU for magnet protection. The Local MPS module takes fast Interlock inputs from one cell of the Storage Ring or one quadrant of the Booster. Fast interlocks are those that must drop the beam in under 400 μsec (the maximum speed of the interlock) in the event of failure. EPIC provides the user interface to the MPS system

  8. Avionics systems integration technology

    Science.gov (United States)

    Stech, George; Williams, James R.

    1988-01-01

    A very dramatic and continuing explosion in digital electronics technology has been taking place in the last decade. The prudent and timely application of this technology will provide Army aviation the capability to prevail against a numerically superior enemy threat. The Army and NASA have exploited this technology explosion in the development and application of avionics systems integration technology for new and future aviation systems. A few selected Army avionics integration technology base efforts are discussed. Also discussed is the Avionics Integration Research Laboratory (AIRLAB) that NASA has established at Langley for research into the integration and validation of avionics systems, and evaluation of advanced technology in a total systems context.

  9. System integration for radiation records

    International Nuclear Information System (INIS)

    Lawson, B.J.; Farrell, L.; Meacham, C.; Tapio, J.

    1994-01-01

    System integration is the process where through networking and/or software development, necessary business information is available in a common computing environment. System integration is becoming an important objective for many businesses. System integration can improve productivity and efficiency, reduce redundant stored information and errors, and improve availability of information. This paper will discuss the information flow in a radiation health environment, and how system integration can help. Information handled includes external dosimetry and internal dosimetry. The paper will focus on an ORACLE based system integration software product

  10. Study concerning the power plant control and safety equipment by integrated distributed systems

    International Nuclear Information System (INIS)

    Optea, I.; Oprea, M.; Stanescu, P.

    1995-01-01

    The paper deals with the trends existing in the field of nuclear control and safety equipment and systems, proposing a high-efficiency integrated system. In order to enhance the safety of the plant and reliability of the structure system and components, we present a concept based on the latest computer technology with an open, distributed system, connected by a local area network with high redundancy. A modern conception for the control and safety system is to integrate all the information related to the reactor protection, active engineered safeguard and auxiliary systems parameters, offering a fast flow of information between all the agencies concerned so that situations can be quickly assessed. The integrated distributed control is based on a high performance operating system for realtime applications, flexible enough for transparent networking and modular for demanding configurations. The general design considerations for nuclear reactors instrumentation reliability and testing methods for real-time functions under dynamic regime are presented. Taking into account the fast progress in information technology, we consider the replacement of the old instrumentation of Cernavoda-1 NPP by a modern integrated system as an economical and efficient solution for the next units. (Author) 20 Refs

  11. Integrated management systems

    CERN Document Server

    Bugdol, Marek

    2015-01-01

    Examining the challenges of integrated management, this book explores the importance and potential benefits of using an integrated approach as a cross-functional concept of management. It covers not only standardized management systems (e.g. International Organization for Standardization), but also models of self-assessment, as well as different types of integration. Furthermore, it demonstrates how processes and systems can be integrated, and how management efficiency can be increased. The major part of this book focuses on management concepts which use integration as a key tool of management processes (e.g. the systematic approach, supply chain management, virtual and network organizations, processes management and total quality management). Case studies, illustrations, and tables are also provided to exemplify and illuminate the content, as well as examples of successful and failed integrations. Providing a particularly useful resource to managers and specialists involved in the improvement of organization...

  12. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1977-01-01

    Reactor Protection Systems for Nuclear Power Plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. This paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  13. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1976-01-01

    Reactor protection systems for nuclear power plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. The paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  14. Comparison, with regard to safety, between a hard-wired reactor protection system and a computerized protection system. Pt. 1

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1976-07-01

    The study compares a conventional hard-wired dynamic reactor protection system with a computerized protection system. In the comparison, only the unequivocally safety-oriented protection actions are considered. In the first part, the different structures of both systems and the method of verification for their functional safety will be described. In the second part, the mean unavailability in case of demand for both systems under defined conditions will be determined. (orig.) [de

  15. Management information system on radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela, E-mail: pabloag@cdtn.b, E-mail: lss@cdtn.b, E-mail: gmf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  16. Management information system on radiation protection

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela

    2011-01-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  17. Distributed radiation protection console system

    International Nuclear Information System (INIS)

    Chhokra, R.S.; Deshpande, V.K.; Mishra, H.; Rajeev, K.P.; Thakur, Bipla B.; Munj, Niket

    2004-01-01

    Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or will get to know the same directly from the installed only after entering the area. This shortcoming can lead to avoidable delays in attending to the work or to unwanted exposure. The authors have designed and developed a system called Distributed Radiation Protection Console (DRPC) to overcome this shortcoming. A DRPC is a console which is located outside the entrance of a given area and displays the radiation status of the area. It presents to health physicist and the plant operators a graphic over-view of the radiation and air activity levels in the particular area of the plant. It also provides audio visual annunciation of the alarm status. Each radioactive area in a nuclear facility will have its own DRPC, which will receive as its inputs the analog and digital signals from radiation monitoring instruments installed in the area and would not only show those readings on its video graphic screen but will also provide warning messages and instructions to the personnel entering the active areas. The various DRPCs can be integrated into a Local Area Network, where the

  18. Protecting plutonium: physical safeguards

    International Nuclear Information System (INIS)

    Ney, J.F.

    1975-10-01

    In the development of physical protection systems, objectives for improving overall performance include the following: (1) Increase the time required for the malefactor to achieve his goal; (2) decrease the time required for detection of malevolent activities; (3) reduce the time for adequate response force arrival; (4) increase the capability to neutralize the malefactor; (5) reduce the total protection system costs, while increasing the level of protection; (6) improve acceptance levels (social, environmental, legal, and institutional); and (7) increase nuclear fuel cycle safety. Fortunately, there is sufficient lead time and technical base to explore and develop new protection system concepts so that a completely integrated and tested protection system capable of providing unprecedented levels of security can be available when needed. Although it will be impossible to completely eliminate all risks, it should be both possible and economically feasible to install protection systems which will deter or prevent a malefactor from using the nuclear fuel cycle to disrupt society

  19. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  20. Advanced Protection & Service Restoration for FREEDM Systems

    Science.gov (United States)

    Singh, Urvir

    A smart electric power distribution system (FREEDM system) that incorporates DERs (Distributed Energy Resources), SSTs (Solid State Transformers - that can limit the fault current to two times of the rated current) & RSC (Reliable & Secure Communication) capabilities has been studied in this work in order to develop its appropriate protection & service restoration techniques. First, a solution is proposed that can make conventional protective devices be able to provide effective protection for FREEDM systems. Results show that although this scheme can provide required protection but it can be quite slow. Using the FREEDM system's communication capabilities, a communication assisted Overcurrent (O/C) protection scheme is proposed & results show that by using communication (blocking signals) very fast operating times are achieved thereby, mitigating the problem of conventional O/C scheme. Using the FREEDM System's DGI (Distributed Grid Intelligence) capability, an automated FLISR (Fault Location, Isolation & Service Restoration) scheme is proposed that is based on the concept of 'software agents' & uses lesser data (than conventional centralized approaches). Test results illustrated that this scheme is able to provide a global optimal system reconfiguration for service restoration.

  1. Specific features of modern voice protection systems

    Directory of Open Access Journals (Sweden)

    Roman A. Ustinov

    2017-11-01

    Full Text Available Nowadays, speech technologies are among the most vibrant sectors of the world’s economy. Of high importance is the problem of ensuring the security of speech information (SI. Here we discuss SI protection systems within a modern communication model. The model is multimodal, multithreaded, and implies a large number of subscribers interacting via several communication lines. With this in mind, we perform a detailed analysis of threats to the confidentiality, integrity and accessibility of SI. Existing methods of counteraction against these threats are discussed, and shown to be insufficient to ensure the safety of voice messages (VM in full. Mean while, there are new threats to the integrity and accessibility of SI, the solutions for which are either do not exist, or only being developed. We propose our original approach to counter these threats. Steganography methods are the most promising for ensuring the integrity of the VM.  In particular, using audiomarkers allows one to reliably trace speaker’sidentity throughout the entire communication session. In order to counter the threats to SI availability due to the capacity of the communication channel and the limited volumes of VM data storage, it is necessary to improve existing adaptive speech compression algorithms, along with developing new ones. Furthermore, such algorithms must keep the specified level of speech intelligibility.

  2. Systems Integration Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-06-01

    This fact sheet is an overview of the Systems Integration subprogram at the U.S. Department of Energy SunShot Initiative. The Systems Integration subprogram enables the widespread deployment of safe, reliable, and cost-effective solar energy technologies by addressing the associated technical and non-technical challenges. These include timely and cost-effective interconnection procedures, optimal system planning, accurate prediction of solar resources, monitoring and control of solar power, maintaining grid reliability and stability, and many more. To address the challenges associated with interconnecting and integrating hundreds of gigawatts of solar power onto the electricity grid, the Systems Integration program funds research, development, and demonstration projects in four broad, interrelated focus areas: grid performance and reliability, dispatchability, power electronics, and communications.

  3. System and Software Design for the Plant Protection System for Shin-Hanul Nuclear Power Plant Units 1 and 2

    International Nuclear Information System (INIS)

    Hwang, In Seok; Kim, Young Geul; Choi, Woong Seock; Sohn, Se Do

    2015-01-01

    The Reactor Protection System(RPS) protects the core fuel design limits and reactor coolant system pressure boundary for Anticipated Operational Occurrences (AOOs), and provides assistance in mitigating the consequences of Postulated Accidents (PAs). The ESFAS sends the initiation signals to Engineered Safety Feature - Component Control System (ESF-CCS) to mitigate consequences of design basis events. The Common Q platform Programmable Logic Controller (PLC) was used for Shin-Wolsung Nuclear Power Plant Units 1 and 2 and Shin-Kori Nuclear Power Plant Units 1, 2, 3 and 4 since Digital Plant Protection System (DPPS) based on Common Q PLC was applied for Ulchin Nuclear Power Plant Units 5 and 6. The PPS for Shin-Hanul Nuclear Power Plant Units 1 and 2 (SHN 1 and 2) was developed using POSAFE-Q PLC for the first time for the PPS. The SHN1 and 2 PPS was delivered to the sites after completion of Man Machine Interface System Integrated System Test (MMIS-IST). The SHN1 and 2 PPS was developed to have the redundancy in each channel and to use the benefits of POSAFE-Q PLC, such as diagnostic and data communication. The PPS application software was developed using ISODE to minimize development time and human errors, and to improve software quality, productivity, and reusability

  4. System and Software Design for the Plant Protection System for Shin-Hanul Nuclear Power Plant Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Seok; Kim, Young Geul; Choi, Woong Seock; Sohn, Se Do [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    The Reactor Protection System(RPS) protects the core fuel design limits and reactor coolant system pressure boundary for Anticipated Operational Occurrences (AOOs), and provides assistance in mitigating the consequences of Postulated Accidents (PAs). The ESFAS sends the initiation signals to Engineered Safety Feature - Component Control System (ESF-CCS) to mitigate consequences of design basis events. The Common Q platform Programmable Logic Controller (PLC) was used for Shin-Wolsung Nuclear Power Plant Units 1 and 2 and Shin-Kori Nuclear Power Plant Units 1, 2, 3 and 4 since Digital Plant Protection System (DPPS) based on Common Q PLC was applied for Ulchin Nuclear Power Plant Units 5 and 6. The PPS for Shin-Hanul Nuclear Power Plant Units 1 and 2 (SHN 1 and 2) was developed using POSAFE-Q PLC for the first time for the PPS. The SHN1 and 2 PPS was delivered to the sites after completion of Man Machine Interface System Integrated System Test (MMIS-IST). The SHN1 and 2 PPS was developed to have the redundancy in each channel and to use the benefits of POSAFE-Q PLC, such as diagnostic and data communication. The PPS application software was developed using ISODE to minimize development time and human errors, and to improve software quality, productivity, and reusability.

  5. Reliability analysis of the reactor protection system with fault diagnosis

    International Nuclear Information System (INIS)

    Lee, D.Y.; Han, J.B.; Lyou, J.

    2004-01-01

    The main function of a reactor protection system (RPS) is to maintain the reactor core integrity and reactor coolant system pressure boundary. The RPS consists of the 2-out-of-m redundant architecture to assure a reliable operation. The system reliability of the RPS is a very important factor for the probability safety assessment (PSA) evaluation in the nuclear field. To evaluate the system failure rate of the k-out-of-m redundant system is not so easy with the deterministic method. In this paper, the reliability analysis method using the binomial process is suggested to calculate the failure rate of the RPS system with a fault diagnosis function. The suggested method is compared with the result of the Markov process to verify the validation of the suggested method, and applied to the several kinds of RPS architectures for a comparative evaluation of the reliability. (orig.)

  6. The systems integration modeling system

    International Nuclear Information System (INIS)

    Danker, W.J.; Williams, J.R.

    1990-01-01

    This paper discusses the systems integration modeling system (SIMS), an analysis tool for the detailed evaluation of the structure and related performance of the Federal Waste Management System (FWMS) and its interface with waste generators. It's use for evaluations in support of system-level decisions as to FWMS configurations, the allocation, sizing, balancing and integration of functions among elements, and the establishment of system-preferred waste selection and sequencing methods and other operating strategies is presented. SIMS includes major analysis submodels which quantify the detailed characteristics of individual waste items, loaded casks and waste packages, simulate the detailed logistics of handling and processing discrete waste items and packages, and perform detailed cost evaluations

  7. A method for establishing integrity in software-based systems

    International Nuclear Information System (INIS)

    Staple, B.D.; Berg, R.S.; Dalton, L.J.

    1997-01-01

    In this paper, the authors present a digital system requirements specification method that has demonstrated a potential for improving the completeness of requirements while reducing ambiguity. It assists with making proper digital system design decisions, including the defense against specific digital system failures modes. It also helps define the technical rationale for all of the component and interface requirements. This approach is a procedural method that abstracts key features that are expanded in a partitioning that identifies and characterizes hazards and safety system function requirements. The key system features are subjected to a hierarchy that progressively defines their detailed characteristics and components. This process produces a set of requirements specifications for the system and all of its components. Based on application to nuclear power plants, the approach described here uses two ordered domains: plant safety followed by safety system integrity. Plant safety refers to those systems defined to meet the safety goals for the protection of the public. Safety system integrity refers to systems defined to ensure that the system can meet the safety goals. Within each domain, a systematic process is used to identify hazards and define the corresponding means of defense and mitigation. In both domains, the approach and structure are focused on the completeness of information and eliminating ambiguities in the generation of safety system requirements that will achieve the plant safety goals

  8. Foundations for Protecting Renewable-Rich Distribution Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brahma, Sukumar [New Mexico State Univ., Las Cruces, NM (United States); Ranade, Satish [New Mexico State Univ., Las Cruces, NM (United States)

    2016-11-01

    High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid introduces new challenges to protection of such systems. This is because the existing protection systems are designed with two assumptions: 1) system is single-sourced, resulting in unidirectional fault current, and (2) fault currents are easily detectable due to much higher magnitudes compared to load currents. Due to the fact that most renewables interface with the grid though inverters, and inverters restrict their current output to levels close to the full load currents, both these assumptions are no longer valid - the system becomes multi-sourced, and overcurrent-based protection does not work. The primary scope of this study is to analyze the response of a grid-tied inverter to different faults in the grid, leading to new guidelines on protecting renewable-rich distribution systems.

  9. ADVANCED WORKER PROTECTION SYSTEM

    International Nuclear Information System (INIS)

    Judson Hedgehock

    2001-01-01

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  10. ADVANCED WORKER PROTECTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Judson Hedgehock

    2001-03-16

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  11. Implementation of an Integrated Information Management System for the US DOE Hanford Tank Farms Project

    International Nuclear Information System (INIS)

    Joyner, William Scott; Knight, Mark A.

    2013-01-01

    In its role as the Tank Operations Contractor at the U.S. Department of Energy's site in Hanford, WA, Washington River Protection Solutions, LLC is implementing an integrated document control and configuration management system. This system will combine equipment data with technical document data that currently resides in separate disconnected databases. The new system will provide integrated information, enabling users to more readily identify the documents that relate to a structure, system, or component and vice-versa. Additionally, the new system will automate engineering work processes through electronic workflows, and where practical and feasible provide integration with design authoring tools. Implementation of this system will improve configuration management of the technical baseline, increase work process efficiencies, support the efficient design of future large projects, and provide a platform for the efficient future turnover of technical baseline data and information

  12. Implementation of an Integrated Information Management System for the US DOE Hanford Tank Farms Project

    Energy Technology Data Exchange (ETDEWEB)

    Joyner, William Scott; Knight, Mark A.

    2013-11-14

    In its role as the Tank Operations Contractor at the U.S. Department of Energy's site in Hanford, WA, Washington River Protection Solutions, LLC is implementing an integrated document control and configuration management system. This system will combine equipment data with technical document data that currently resides in separate disconnected databases. The new system will provide integrated information, enabling users to more readily identify the documents that relate to a structure, system, or component and vice-versa. Additionally, the new system will automate engineering work processes through electronic workflows, and where practical and feasible provide integration with design authoring tools. Implementation of this system will improve configuration management of the technical baseline, increase work process efficiencies, support the efficient design of future large projects, and provide a platform for the efficient future turnover of technical baseline data and information.

  13. An intelligent and integrated V and V environment design for NPP I and C software systems

    International Nuclear Information System (INIS)

    Koo, Seo Ryong; Son Han Seong; Seong, Poong Hyun

    2001-01-01

    Nuclear Power Plant (NPP) is the safety critical system. Since, nuclear instrumentation and control (I and C) systems including the plant protection system play the brain part of human, nuclear I and C systems have an influence on safety and operation of NPP. Essentially, software V and V should be performed for the safety critical systems based on software. It is very important in the technical aspect because of the problems concerning license acquisitions. In this work, an intelligent and integrated V and V environment supporting the automation of V and V was designed. The intelligent and integrated V and V environment consists of the intelligent controller part, components part, interface part, and GUI part. These parts were integrated systematically, while taking their own independent functions

  14. Passive safety systems for integral reactors

    International Nuclear Information System (INIS)

    Kuul, V.S.; Samoilov, O.B.

    1996-01-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs

  15. Passive safety systems for integral reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kuul, V S; Samoilov, O B [OKB Mechanical Engineering (Russian Federation)

    1996-12-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs.

  16. Explosion-protected electric heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Elsner, H

    1984-02-01

    Different constructions of explosion-protected heating systems are described concerning the different types of protection, the service conditions, the installation and the surveillance devices. Interpretations and regulations derived from the VDE Standards are discussed and their relation to the European Standards EN 50014 ... 50020 is considered in a survey.

  17. Unmanned Ground Vehicles for Integrated Force Protection

    Science.gov (United States)

    2004-04-01

    employed. 2 Force Protection 18 MAR 02 Security Posts Squad Laptop Fire Tm Ldr Wearable Computers OP/LP Def Fight Psn SRT Sensors USA, USMC, Allied...visual systems. Attaching sensors and response devices on a monorail proved to be much more technically challenging than expected. Film producers and...facilitate experimentation with weapon aiming and firing techniques from the MRHA. grated Marsupial Delivery System was developed to transport smaller

  18. The protection system to Brazilian Nuclear Program

    International Nuclear Information System (INIS)

    Andreuzza, Mario Giussepp Santezzi Bertottelli

    1997-01-01

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author)

  19. Modern integrated environmental monitoring and processing systems for nuclear facilities

    International Nuclear Information System (INIS)

    Oprea, I.

    2000-01-01

    The continuous activity to survey and monitor releases and the current radiation levels in the vicinity of a nuclear object is essential for person and environment protection. Considering the vast amount of information and data needed to keep an updated overview of a situation both during the daily surveillance work and during accident situations, the need for an efficient monitoring and processing system is evident. The rapid development, both in computer technology and in telecommunications, the evolution of fast and accurate computer codes enabling the on-line calculations improve the quality of decision-making in complex situations and assure a high efficiency. The monitoring and processing systems are used both for environmental protection and for controlling nuclear power plant emergency and post-accident situations. Such a system can offer information to the radiation management systems in order to assess the consequences of nuclear accidents and to establish a basis for right decisions in civil defense. The integrated environmental monitoring systems have as main task to record, collect, process and transmit the radiation levels and weather data, incorporating a number of stationary or mobile radiation monitoring equipment, weather parameter measuring station, an information processing center and the communication network, all running under a real-time operating system.They provide the automatic data collection on-line and off-line, remote diagnostic, advanced presentation techniques, including a graphically oriented executive support, which has the ability to respond to an emergency by geographical representation of the hazard zones on the map. The systems are based on local intelligent measuring and transmission units, simultaneous processing and data presentation using a real-time operating system for personal computers and geographical information system (GIS). All information can be managed directly from the map by multilevel data retrieving and

  20. The APS machine protection system (MPS)

    Energy Technology Data Exchange (ETDEWEB)

    Fuja, R.; Berg, B.; Arnold, N. [and others

    1996-08-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented.

  1. The APS machine protection system (MPS)

    International Nuclear Information System (INIS)

    Fuja, R.; Berg, B.; Arnold, N.

    1996-01-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented

  2. 46 CFR 154.1110 - Areas protected by system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Areas protected by system. 154.1110 Section 154.1110... Firefighting § 154.1110 Areas protected by system. Each water spray system must protect: (a) All cargo tank... valves essential to cargo flow; (f) Each boundary facing the cargo area of each superstructure that...

  3. Systems integration (automation system). System integration (automation system)

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, K; Komori, T; Fukuma, Y; Oikawa, M [Nippon Steal Corp., Tokyo (Japan)

    1991-09-26

    This paper introduces business activities on an automation systems integration (SI) started by a company in July,1988, and describes the SI concepts. The business activities include, with the CIM (unified production carried out on computers) and AMENITY (living environment) as the mainstays, a single responsibility construction ranging from consultation on structuring optimal systems for processing and assembling industries and intelligent buildings to system design, installation and after-sales services. With an SI standing on users {prime} position taken most importantly, the business starts from a planning and consultation under close coordination. On the conceptual basis of structuring optimal systems using the ompany {prime}s affluent know-hows and tools and adapting and applying with multi-vendors, open networks, centralized and distributed systems, the business is promoted with the accumulated technologies capable of realizing artificial intelligence and neural networks in its background, and supported with highly valuable business results in the past. 10 figs., 1 tab.

  4. Modern thyratron crowbar protection systems

    International Nuclear Information System (INIS)

    Judd, D.A.; Kettle, L.J.; Menown, H.; Newton, B.P.; Nicholls, N.S.; Sheldrake, R.

    1992-01-01

    Two thyratron crowbar systems for high-power klystrons used in linear accelerators are described. The first, contained in an oil filled tank, is a complete system to protect a klystron powered from a 100-kV, 20-A d.c. supply. In the second system a CX1722 glass thyratron, operating in air, has been retrofitted to a test equipment, in place of a spark gap, to protect an Inductive Output Tube (IOT). An important parameter in the choice of the crowbar thyratron is the total coulombs to be switched. Measurements of these follow-on currents are presented. (R.P.) 4 refs.; 10 figs

  5. Standpipe systems for fire protection

    CERN Document Server

    Isman, Kenneth E

    2017-01-01

    This important new manual goes beyond the published NFPA standards on installation of standpipe systems to include the rules in the International Building Code, municipal fire codes, the National Fire Code of Canada, and information on inspection, testing, and maintenance of standpipe systems. Also covered are the interactions between standpipe and sprinkler systems, since these important fire protection systems are so frequently installed together. Illustrated with design examples and practical applications to reinforce the learning experience, this is the go-to reference for engineers, architects, design technicians, building inspectors, fire inspectors, and anyone that inspects, tests or maintains fire protection systems. Fire marshals and plan review authorities that have the responsibility for reviewing and accepting plans and hydraulic calculations for standpipe systems are also an important audience, as are firefighters who actually use standpipe systems. As a member of the committees responsible for s...

  6. Aging assessment for active fire protection systems

    International Nuclear Information System (INIS)

    Ross, S.B.; Nowlen, S.P.; Tanaka, T.

    1995-06-01

    This study assessed the impact of aging on the performance and reliability of active fire protection systems including both fixed fire suppression and fixed fire detection systems. The experience base shows that most nuclear power plants have an aggressive maintenance and testing program and are finding degraded fire protection system components before a failure occurs. Also, from the data reviewed it is clear that the risk impact of fire protection system aging is low. However, it is assumed that a more aggressive maintenance and testing program involving preventive diagnostics may reduce the risk impact even further

  7. A New Protection System for Islanding Detection in LV Distribution Systems

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2015-04-01

    Full Text Available The growth of penetration of Distributed Generators (DGs is increasing the risk of unwanted islanded operation in Low Voltage (LV distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

  8. Data Content Protection for Virtual Libraries Heritage

    Directory of Open Access Journals (Sweden)

    Mihai DOINEA

    2016-01-01

    Full Text Available This paper presents aspects of digital content protection in virtual library systems. The legislation aspects are presented to better emphasize the need of new security mechanisms. Integrated library systems architecture is presented with focus on their main purpose, manipulating and rendering digital content to end-users. The cultural heritage stored in such systems is an important asset that needs to be protected against malicious manipulation. The characteristics of a smart virtual library, supported by an integrated library system, are analyzed and a security model is proposed for implementation, based on its particularities. The model aims to be an interface between the interactions of anonymous users with the Online Public Access Catalog of a virtual library that assures the protection of digital content. Conclusions are drawn to better support the idea of cultural persistence by the use of Information Systems.

  9. Spent Nuclear Fuel (SNF) project Integrated Safety Management System phase I and II Verification Review Plan

    International Nuclear Information System (INIS)

    CARTER, R.P.

    1999-01-01

    The U.S. Department of Energy (DOE) commits to accomplishing its mission safely. To ensure this objective is met, DOE issued DOE P 450.4, Safety Management System Policy, and incorporated safety management into the DOE Acquisition Regulations ([DEAR] 48 CFR 970.5204-2 and 90.5204-78). Integrated Safety Management (ISM) requires contractors to integrate safety into management and work practices at all levels so that missions are achieved while protecting the public, the worker, and the environment. The contractor is required to describe the Integrated Safety Management System (ISMS) to be used to implement the safety performance objective

  10. Spent Nuclear Fuel (SNF) project Integrated Safety Management System phase I and II Verification Review Plan

    Energy Technology Data Exchange (ETDEWEB)

    CARTER, R.P.

    1999-11-19

    The U.S. Department of Energy (DOE) commits to accomplishing its mission safely. To ensure this objective is met, DOE issued DOE P 450.4, Safety Management System Policy, and incorporated safety management into the DOE Acquisition Regulations ([DEAR] 48 CFR 970.5204-2 and 90.5204-78). Integrated Safety Management (ISM) requires contractors to integrate safety into management and work practices at all levels so that missions are achieved while protecting the public, the worker, and the environment. The contractor is required to describe the Integrated Safety Management System (ISMS) to be used to implement the safety performance objective.

  11. Bioactivities of Milk Polar Lipids in Influencing Intestinal Barrier Integrity, Systemic Inflammation, and Lipid Metabolism

    OpenAIRE

    Zhou, Albert Lihong

    2013-01-01

    The purpose of lactation is for nutrient provision and also importantly for protection from various environmental stressors. Milk polar lipids reduce cholesterol, protect against bacterial infection, reduce inflammation and help maintain gut integrity. Dynamic interactions within dietary fat, lipid metabolism, gut permeability and inflammatory cytokines remain unclear in the context of obesity and systemic inflammation. A rat model and three mouse models were developed to test the hypotheses ...

  12. A protection system for picosecond accelerator

    International Nuclear Information System (INIS)

    Cao Hongping; Chinese Academy of Sciences, Beijing; Chen Huanguang; Xu Ruinian; Tang Junlong; Li Deming

    2006-01-01

    A personnel and machine protection system for the picosecond accelerator has been built. The key of the system is to send on/off of three triggering signals which are those of electron gun, 2856 MHz and 476 MHz, respectively, to ensure the safety of users and the accelerator. This paper describes the emergencies interlocked by ADAM5511 and timing trigger processor, and some secondary functions which improve the efficiency of the protection system completed in upper layer software. (authors)

  13. Integrated environmental protection obligations under European law, survey analysis of Austrian legislation

    International Nuclear Information System (INIS)

    Berthaler, W.

    2001-05-01

    This work focuses on legal instruments serving integrated environmental protection, especially with respect to administrative procedures concerning plant permits, and their inhorent limits. Initially, the legal and scientific approach pursued under the notion of 'integrated environmental protection' and 'environmental impact assessment' is examined and clarified in chapter A. Based thereon, chapter B deals with the obligations resulting from the EIA-Directive and - compared therewith - from the IPPC-Directive with regard to procedures for plant permits. Further, Austria's delay in fully transposing these directives is examined. When dealing with the constitutional basis for transposing the EIA- and IPPC-D into Austrian administrative law (chapter C), the inherent limits of some competence of legislation are discovered to be too narrow to ensure full compliance with EC law; only with regard to EIA, legistation is based on sound constitutional ground. The second part of the work is devoted to three areas of discussion on EIA- and IPPC-procedures under Austrian law: the scope of their applicability (chapter D), the problems of integrated evaluation and the limits of ecological expertise (chapter E) and aspects of public participation (chapter F). The study is concluded by a summary of the main results (chapter G). (author)

  14. Challenges and opportunities in providing a digital protection system for the PBMR - HTR2008-58173

    International Nuclear Information System (INIS)

    Marais, J.; Ridolfo, C. F.

    2008-01-01

    The Republic of South Africa is currently developing the Pebble Bed Modular Reactor (PBMR); an advanced, fourth-generation reactor that incorporates inherent safety features, which require no human intervention and which provide an unprecedented level of nuclear safety. In addition to electrical power generation, the reactor is uniquely suited for a variety of non-traditional nuclear applications including oil sands extraction, desalination, and hydrogen production. A state-of-the-art digital Protection System for the PBMR is currently being developed in conjunction with Westinghouse Electric Company (WEC). The Protection System provides for: reactor shutdown using two different reactor trip methodologies (dropping of the control rods and insertion of Small Absorber Spheres (SASs) which are composed of boron carbide); post-event monitoring; and manual reactor shutdown, which is independent of software-based systems. The reactor shutdown and post-event instrumentation monitoring components of the Protection System are being implemented utilizing the WEC 'Common Q' platform, which is comprised of 'commercially dedicated' Programmable Logic Controllers (PLCs), colour-graphic Flat Panel Displays (FPDs) with integral touch screens, and high-speed data communication links. High reliability and availability are achieved through component redundancy, continuous automatic self-testing which is run online in a background mode, and implementation of a multi-channel system design which is tolerant to failures. The Protection System is also designed to support periodic surveillance testing through a suite of built- in computer-aided test facilities that are accessible via an FPD interface. These allow various system surveillance requirements to be readily performed in a convenient and systematic manner. This paper discusses the following topics with regard to the PBMR Protection System: development strategy, functional requirements, selection of applicable Codes and Standards

  15. The overvoltage protection module for the power supply system for the pixel detector at Belle II experiment at KEK

    International Nuclear Information System (INIS)

    Kapusta, P.; Kisielewski, B.

    2015-01-01

    In this paper the overvoltage protection modules (OVP) for the power supply (PS) system of the Belle II pixel detector (PXD) are described. The aim of the OVP is to protect the detector and associated electronics against overvoltage conditions. Most critical in the system are voltages supplying the front-end ASICs. The PXD detector consists of the DEPFET sensor modules with integrated chips like the Drain Current Digitizer, the Switcher and the Data Handling Processor. These chips, implemented in modern sub-micron technologies, are quite vulnerable to variations in the supply voltages. The PXD will be placed in the Belle II experiment as close as possible to the interaction point, where access during experiment is very limited or even impossible, thus the PS and OVP systems exploit the remote-sensing method. Overvoltage conditions are due to failures of the PS itself, wrong setting of the output voltages or transient voltages coming out of hard noisy environment of the experiment. The OVP modules are parts of the PS modules. For powering the PXD 40 PS modules are placed 15 m outside the Belle II spectrometer. Each one is equipped with the OVP board. All voltages (22) are grouped in 4 domains: Analog, Digital, Steering and Gate which have independent grounds. The OVP boards are designed from integrated circuits from Linear Technology. All configurations were simulated with the Spice program. The control electronics is designed in a Xilinx CPLD. Two types of integrated circuits were used. LT4356 surge stopper protects loads from high voltage transients. The output voltages are limited to a safe value and also protect loads against over current faults. For less critical voltages, the LTC2912 voltage monitors are used that detect under-voltage and overvoltage events. It has to be noted that the OVP system is working independently of any other protection of the PS system, which increases its overall reliability. (authors)

  16. The overvoltage protection module for the power supply system for the pixel detector at Belle II experiment at KEK

    Energy Technology Data Exchange (ETDEWEB)

    Kapusta, P.; Kisielewski, B. [Institute of Nuclear Physics PAN, ul.Radzikowskiego 152, 31-875 Krakow, (Poland)

    2015-07-01

    In this paper the overvoltage protection modules (OVP) for the power supply (PS) system of the Belle II pixel detector (PXD) are described. The aim of the OVP is to protect the detector and associated electronics against overvoltage conditions. Most critical in the system are voltages supplying the front-end ASICs. The PXD detector consists of the DEPFET sensor modules with integrated chips like the Drain Current Digitizer, the Switcher and the Data Handling Processor. These chips, implemented in modern sub-micron technologies, are quite vulnerable to variations in the supply voltages. The PXD will be placed in the Belle II experiment as close as possible to the interaction point, where access during experiment is very limited or even impossible, thus the PS and OVP systems exploit the remote-sensing method. Overvoltage conditions are due to failures of the PS itself, wrong setting of the output voltages or transient voltages coming out of hard noisy environment of the experiment. The OVP modules are parts of the PS modules. For powering the PXD 40 PS modules are placed 15 m outside the Belle II spectrometer. Each one is equipped with the OVP board. All voltages (22) are grouped in 4 domains: Analog, Digital, Steering and Gate which have independent grounds. The OVP boards are designed from integrated circuits from Linear Technology. All configurations were simulated with the Spice program. The control electronics is designed in a Xilinx CPLD. Two types of integrated circuits were used. LT4356 surge stopper protects loads from high voltage transients. The output voltages are limited to a safe value and also protect loads against over current faults. For less critical voltages, the LTC2912 voltage monitors are used that detect under-voltage and overvoltage events. It has to be noted that the OVP system is working independently of any other protection of the PS system, which increases its overall reliability. (authors)

  17. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J. [Oceaneering Space Systems, Houston, TX (United States)

    1995-10-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment.

  18. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment

  19. Encryption protection for communication satellites

    Science.gov (United States)

    Sood, D. R.; Hoernig, O. W., Jr.

    In connection with the growing importance of the commercial communication satellite systems and the introduction of new technological developments, users and operators of these systems become increasingly concerned with aspects of security. The user community is concerned with maintaining confidentiality and integrity of the information being transmitted over the satellite links, while the satellite operators are concerned about the safety of their assets in space. In response to these concerns, the commercial satellite operators are now taking steps to protect the communication information and the satellites. Thus, communication information is being protected by end-to-end encryption of the customer communication traffic. Attention is given to the selection of the NBS DES algorithm, the command protection systems, and the communication protection systems.

  20. Functional issues and environmental qualification of digital protection systems of advanced light-water nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Clark, R.L.; Wood, R.T. [Oak Ridge National Lab., TN (United States)

    1994-04-01

    Issues of obsolescence and lack of infrastructural support in (analog) spare parts, coupled with the potential benefits of digital systems, are driving the nuclear industry to retrofit analog instrumentation and control (I&C) systems with digital and microprocessor-based systems. While these technologies have several advantages, their application to safety-related systems in nuclear power plants raises key issues relating to the systems` environmental qualification and functional reliability. To bound the problem of new I&C system functionality and qualification, the authors focused this study on protection systems proposed for use in ALWRs. Specifically, both functional and environmental qualification issues for ALWR protection system I&C were addressed by developing an environmental, functional, and aging data template for a protection division of each proposed ALWR design. By using information provided by manufacturers, environmental conditions and stressors to which I&C equipment in reactor protection divisions may be subjected were identified. The resulting data were then compared to a similar template for an instrument string typically found in an analog protection division of a present-day nuclear power plant. The authors also identified fiber-optic transmission systems as technologies that are relatively new to the nuclear power plant environment and examined the failure modes and age-related degradation mechanisms of fiber-optic components and systems. One reason for the exercise of caution in the introduction of software into safety-critical systems is the potential for common-cause failure due to the software. This study, however, approaches the functionality problem from a systems point of view. System malfunction scenarios are postulated to illustrate the fact that, when dealing with the performance of the overall integrated system, the real issues are functionality and fault tolerance, not hardware vs. software.

  1. Functional issues and environmental qualification of digital protection systems of advanced light-water nuclear reactors

    International Nuclear Information System (INIS)

    Korsah, K.; Clark, R.L.; Wood, R.T.

    1994-04-01

    Issues of obsolescence and lack of infrastructural support in (analog) spare parts, coupled with the potential benefits of digital systems, are driving the nuclear industry to retrofit analog instrumentation and control (I ampersand C) systems with digital and microprocessor-based systems. While these technologies have several advantages, their application to safety-related systems in nuclear power plants raises key issues relating to the systems' environmental qualification and functional reliability. To bound the problem of new I ampersand C system functionality and qualification, the authors focused this study on protection systems proposed for use in ALWRs. Specifically, both functional and environmental qualification issues for ALWR protection system I ampersand C were addressed by developing an environmental, functional, and aging data template for a protection division of each proposed ALWR design. By using information provided by manufacturers, environmental conditions and stressors to which I ampersand C equipment in reactor protection divisions may be subjected were identified. The resulting data were then compared to a similar template for an instrument string typically found in an analog protection division of a present-day nuclear power plant. The authors also identified fiber-optic transmission systems as technologies that are relatively new to the nuclear power plant environment and examined the failure modes and age-related degradation mechanisms of fiber-optic components and systems. One reason for the exercise of caution in the introduction of software into safety-critical systems is the potential for common-cause failure due to the software. This study, however, approaches the functionality problem from a systems point of view. System malfunction scenarios are postulated to illustrate the fact that, when dealing with the performance of the overall integrated system, the real issues are functionality and fault tolerance, not hardware vs. software

  2. Integrated crop protection as a system approach

    NARCIS (Netherlands)

    Haan, de J.J.; Wijnands, F.G.; Sukkel, W.

    2005-01-01

    New farming systems in vegetable production are required as demands for high quality products that do not pollute the environment are rising, and production risks are large and incomes low. The methodology of prototyping new systems is described, especially the themes, parameters and target values

  3. Preliminary design of the thermal protection system for solar probe

    Science.gov (United States)

    Dirling, R. B., Jr.; Loomis, W. C.; Heightland, C. N.

    1982-01-01

    A preliminary design of the thermal protection system for the NASA Solar Probe spacecraft is presented. As presently conceived, the spacecraft will be launched by the Space Shuttle on a Jovian swing-by trajectory and at perihelion approach to three solar radii of the surface of the Earth's sun. The system design satisfies maximum envelope, structural integrity, equipotential, and mass loss/contamination requirements by employing lightweight carbon-carbon emissive shields. The primary shield is a thin shell, 15.5-deg half-angle cone which absorbs direct solar flux at up to 10-deg off-nadir spacecraft pointing angles. Secondary shields of sandwich construction and low thickness-direction thermal conductivity are used to reduce the primary shield infrared radiation to the spacecraft payload.

  4. The Philosophy of the New Radiation Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Wikman, P.

    2004-07-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle ''If the individual is sufficiently protected from a source, then society is also protected from that source''. This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs.

  5. The Philosophy of the New Radiation Protection System

    International Nuclear Information System (INIS)

    Wikman, P.

    2004-01-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle I f the individual is sufficiently protected from a source, then society is also protected from that source . This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs

  6. Idaho National Laboratory Integrated Safety Management System FY 2012 Effectiveness Review and Declaration Report

    Energy Technology Data Exchange (ETDEWEB)

    Farren Hunt

    2012-12-01

    Idaho National Laboratory (INL) performed an Annual Effectiveness Review of the Integrated Safety Management System (ISMS), per 48 Code of Federal Regulations (CFR) 970.5223 1, “Integration of Environment, Safety and Health into Work Planning and Execution.” The annual review assessed Integrated Safety Management (ISM) effectiveness, provided feedback to maintain system integrity, and identified target areas for focused improvements and assessments for fiscal year (FY) 2013. Results of the FY 2012 annual effectiveness review demonstrated that the INL’s ISMS program was significantly strengthened. Actions implemented by the INL demonstrate that the overall Integrated Safety Management System is sound and ensures safe and successful performance of work while protecting workers, the public, and environment. This report also provides several opportunities for improvement that will help further strengthen the ISM Program and the pursuit of safety excellence. Demonstrated leadership and commitment, continued surveillance, and dedicated resources have been instrumental in maturing a sound ISMS program. Based upon interviews with personnel, reviews of assurance activities, and analysis of ISMS process implementation, this effectiveness review concludes that ISM is institutionalized and is “Effective”.

  7. The physical protection systems at the Czech nuclear installations and the Y2K issue

    International Nuclear Information System (INIS)

    Malach, J.; Seifert, Z.; Sedlacek, J.; Bartak, L.; Polanka, J.

    1999-01-01

    The paper describes the joint effort of the State Office for Nuclear Safety, EZ, a.s., Nuclear Power Plant Dukovany and EBIS Ltd., as a subcontractor, to solve the problem of the Y2K particularly in connection with real time operation of the integrated physical protection system at Nuclear Power Plant Dukovany. (author)

  8. Televison assessment and identification system for the plutonium protection system

    International Nuclear Information System (INIS)

    Greenwoll, D.A.

    1979-02-01

    This report covers the selection, description, and use of the components comprising the Television Assessment and Identification System in the Hanford Plutonium Protection System. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Facility Physical Protection Program

  9. Systems integration processes for space nuclear electric propulsion systems

    International Nuclear Information System (INIS)

    Olsen, C.S.; Rice, J.W.; Stanley, M.L.

    1991-01-01

    The various components and subsystems that comprise a nuclear electric propulsion system should be developed and integrated so that each functions ideally and so that each is properly integrated with the other components and subsystems in the optimum way. This paper discusses how processes similar to those used in the development and intergration of the subsystems that comprise the Multimegawatt Space Nuclear Power System concepts can be and are being efficiently and effectively utilized for these purposes. The processes discussed include the development of functional and operational requirements at the system and subsystem level; the assessment of individual nuclear power supply and thruster concepts and their associated technologies; the conduct of systems integration efforts including the evaluation of the mission benefits for each system; the identification and resolution of concepts development, technology development, and systems integration feasibility issues; subsystem, system, and technology development and integration; and ground and flight subsystem and integrated system testing

  10. Geometry and dynamics of integrable systems

    CERN Document Server

    Matveev, Vladimir

    2016-01-01

    Based on lectures given at an advanced course on integrable systems at the Centre de Recerca Matemàtica in Barcelona, these lecture notes address three major aspects of integrable systems: obstructions to integrability from differential Galois theory; the description of singularities of integrable systems on the basis of their relation to bi-Hamiltonian systems; and the generalization of integrable systems to the non-Hamiltonian settings. All three sections were written by top experts in their respective fields. Native to actual problem-solving challenges in mechanics, the topic of integrable systems is currently at the crossroads of several disciplines in pure and applied mathematics, and also has important interactions with physics. The study of integrable systems also actively employs methods from differential geometry. Moreover, it is extremely important in symplectic geometry and Hamiltonian dynamics, and has strong correlations with mathematical physics, Lie theory and algebraic geometry (including mir...

  11. A Holistic Approach Including Biological and Geological Criteria for Integrative Management in Protected Areas.

    Science.gov (United States)

    Peña, Lorena; Monge-Ganuzas, Manu; Onaindia, Miren; De Manuel, Beatriz Fernández; Mendia, Miren

    2017-02-01

    Biodiversity hotspots and geosites are indivisible parts of natural heritage. Therefore, an adequate spatial delimitation and understanding of both and their linkages are necessary in order to be able to establish conservation policies. Normally, biodiversity hotspots are a typical target for those policies but, generally, geosites are not taken into account. Thus, this paper aims to fill this gap by providing an easily replicable method for the identification and integration of the geosites and the biodiversity hotspots in a Network for Integrative Nature Conservation that highlights their linkages. The method here presented has been applied to Urdaibai Biosphere Reserve situated in southeastern of the Bay of Biscay. The obtained results indicate that some geosites that are not directly related with biodiversity hotspots remain unprotected. Thus, from the study carried out, it can be stated that we conserving just the biodiversity hotspots is not enough to conserve the whole natural heritage of a protected area, as some plots interesting due to their relevant geoheritage remain unprotected. Therefore, it is necessary to fully integrate geosites into the planning documents of protected areas as a part of an ecosystem approach. The ecosystem approach recognizes the integrity of abiotic and biotic elements in nature conservation policies. Moreover, the proposed framework and the innovative methodology can be used as an easy input to identify priority areas for conservation, to improve the protected areas conservation planning, and to demonstrate the linkages between biodiversity hotspots and geosites.

  12. A Holistic Approach Including Biological and Geological Criteria for Integrative Management in Protected Areas

    Science.gov (United States)

    Peña, Lorena; Monge-Ganuzas, Manu; Onaindia, Miren; De Manuel, Beatriz Fernández; Mendia, Miren

    2017-02-01

    Biodiversity hotspots and geosites are indivisible parts of natural heritage. Therefore, an adequate spatial delimitation and understanding of both and their linkages are necessary in order to be able to establish conservation policies. Normally, biodiversity hotspots are a typical target for those policies but, generally, geosites are not taken into account. Thus, this paper aims to fill this gap by providing an easily replicable method for the identification and integration of the geosites and the biodiversity hotspots in a Network for Integrative Nature Conservation that highlights their linkages. The method here presented has been applied to Urdaibai Biosphere Reserve situated in southeastern of the Bay of Biscay. The obtained results indicate that some geosites that are not directly related with biodiversity hotspots remain unprotected. Thus, from the study carried out, it can be stated that we conserving just the biodiversity hotspots is not enough to conserve the whole natural heritage of a protected area, as some plots interesting due to their relevant geoheritage remain unprotected. Therefore, it is necessary to fully integrate geosites into the planning documents of protected areas as a part of an ecosystem approach. The ecosystem approach recognizes the integrity of abiotic and biotic elements in nature conservation policies. Moreover, the proposed framework and the innovative methodology can be used as an easy input to identify priority areas for conservation, to improve the protected areas conservation planning, and to demonstrate the linkages between biodiversity hotspots and geosites.

  13. The Ural Electrochemical Integrated Plant Process for Managing Equipment Intended for Nuclear Material Protection, Control and Accounting System Upgrades

    International Nuclear Information System (INIS)

    Yuldashev, Rashid; Nosov, Andrei; Carroll, Michael F.; Garrett, Albert G.; Dabbs, Richard D.; Ku, Esther M.

    2008-01-01

    Since 1996, the Ural Electrochemical Integrated Plant (UEIP) located in the town of Novouralsk, Russia, (previously known as Sverdlovsk-44) and the United States Department of Energy (U.S. DOE) have been cooperating under the Nuclear Material Protection, Control and Accounting (MPC and A) Program. Because UEIP is involved in the processing of highly enriched uranium (HEU) into low enriched uranium (LEU), and there are highly enriched nuclear materials on its territory, the main goal of the MPC and A cooperation is to upgrade those systems that ensure secure storage, processing and transportation of nuclear materials at the plant. UEIP has completed key upgrades (equipment procurement and installation) aimed at improving MPC and A systems through significant investments made by both the U.S. DOE and UEIP. These joint cooperative efforts resulted in bringing MPC and A systems into compliance with current regulations, which led to nuclear material (NM) theft risk reduction and prevention from other unlawful actions with respect to them. Upon the U.S. MPC and A project team's suggestion, UEIP has developed an equipment inventory control process to track all the property provided through the MPC and A Program. The UEIP process and system for managing equipment provides many benefits including: greater ease and efficiency in determining the quantities, location, maintenance and repair schedule for equipment; greater assurance that MPC and A equipment is in continued satisfactory operation; and improved control in the development of a site sustainability program. While emphasizing UEIP's equipment inventory control processes, this paper will present process requirements and a methodology that may have practical and helpful applications at other sites.

  14. Integrated RIS-PACS system

    International Nuclear Information System (INIS)

    Nishihara, Eitaro; Kura, Hiroyuki; Fukushima, Yuki

    1994-01-01

    We have developed an integrated RIS-PACS (radiology information system-picture archiving and communication system) system which supports examination, interpretation, and management in the diagnostic imaging department. The system was introduced in the Toshiba Hospital in May 1993, concurrently with the renewal of the hospital facilities. The integrated RIS-PACS system consists of a radiology information management system, and an image management system. The system supports wet (immediate) reading and chronological comparative reading using viewing workstation, enables routine operations to be performed in the diagnostic imaging department without film transportation, and contributes to the improvement of management efficiency in the department. (author)

  15. Training for integrated digital I and C system of Tomari unit 3

    International Nuclear Information System (INIS)

    Tutiya, Akiyoshi; Sanbe, Takayuki; Hayashi, Hiroshi

    2009-01-01

    In Tomari nuclear power station Unit No.3, integrated digital I and C facilities was applied for each control unit including safety protection system overall and which connect them by bus (a network), and perform data communications for the first time as a Japanese PWR power station. For the continuation of safe and stable operation of Tomari nuclear power station Unit No.3 which is our greatest power supply, it is important to perform appropriate maintenance jobs about integrated digital I and C System at the time of normal operation, periodical inspection and trouble outbreak. For the assured accomplishment of these work by maintenance personnel, we clarified goal of necessary knowledge and skills and examined training facilities and curriculums. (author)

  16. Machine Protection System response in 2011

    CERN Document Server

    Zerlauth, M; Wenninger, J

    2012-01-01

    The performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems as well as in the change management will be evaluated along with their impact on the 2012 run. The role of the restricted Machine Protection Panel ( rMPP ) during the various operational phases such as commissioning, the intensity ramp up and Machine Developments is being discussed.

  17. Development of a protection system for research reactor based in Field Programmable Gate Array - FPGA

    International Nuclear Information System (INIS)

    Martins, Roque Hudson da Silva

    2016-01-01

    This study presents a implementation purpose of a protection system for research nuclear reactors by using a programed device FPGA (Field Programmable Gate Array). As well as logic protection method involved on an automatic shutdown (TRIP) of a reactor, that ensure the security on such systems. These new control and operation mechanics are developed to guarantee that the security limits of a power plant are not exceeded, these mechanics can work isolated or in groups to safe guard the security levels. For this implementation to be completed, there will be presented the main aspects and concepts referred to protection systems, mostly about research nuclear reactors, with some applications terms exposed. The system proposed at this paper was developed following the VHDL (Very High Speed Integrated Circuits) hardware describing language, and the Modelsim software from Altera Software to program the automatic turning off routines, and hypothetical simulations for such. The results show that for every software application for supporting nuclear reactors, like security devices, they have to meet the IEC 60880 criteria. This paper have great importance, seeing that nuclear reactor security systems, are a basic element for ensure the reactor security. (author)

  18. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1979-01-01

    An absorber element blow-out protection system for a nuclear reactor having a pressure vessel through which a coolant is circulated. The blow-out protection system includes devices which hydraulically couple groups of guide tubes in which the absorber elements move, the coupling devices limiting coolant lift flow rate to a level commensurate with the raising of individual absorber elements but insufficient to raise a plurality of absorber elements simultaneously

  19. Forecasting in an integrated surface water-ground water system: The Big Cypress Basin, South Florida

    Science.gov (United States)

    Butts, M. B.; Feng, K.; Klinting, A.; Stewart, K.; Nath, A.; Manning, P.; Hazlett, T.; Jacobsen, T.

    2009-04-01

    The South Florida Water Management District (SFWMD) manages and protects the state's water resources on behalf of 7.5 million South Floridians and is the lead agency in restoring America's Everglades - the largest environmental restoration project in US history. Many of the projects to restore and protect the Everglades ecosystem are part of the Comprehensive Everglades Restoration Plan (CERP). The region has a unique hydrological regime, with close connection between surface water and groundwater, and a complex managed drainage network with many structures. Added to the physical complexity are the conflicting needs of the ecosystem for protection and restoration, versus the substantial urban development with the accompanying water supply, water quality and flood control issues. In this paper a novel forecasting and real-time modelling system is presented for the Big Cypress Basin. The Big Cypress Basin includes 272 km of primary canals and 46 water control structures throughout the area that provide limited levels of flood protection, as well as water supply and environmental quality management. This system is linked to the South Florida Water Management District's extensive real-time (SCADA) data monitoring and collection system. Novel aspects of this system include the use of a fully distributed and integrated modeling approach and a new filter-based updating approach for accurately forecasting river levels. Because of the interaction between surface- and groundwater a fully integrated forecast modeling approach is required. Indeed, results for the Tropical Storm Fay in 2008, the groundwater levels show an extremely rapid response to heavy rainfall. Analysis of this storm also shows that updating levels in the river system can have a direct impact on groundwater levels.

  20. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  1. Incipient fault detection and power system protection for spaceborne systems

    Science.gov (United States)

    Russell, B. Don; Hackler, Irene M.

    1987-01-01

    A program was initiated to study the feasibility of using advanced terrestrial power system protection techniques for spacecraft power systems. It was designed to enhance and automate spacecraft power distribution systems in the areas of safety, reliability and maintenance. The proposed power management/distribution system is described as well as security assessment and control, incipient and low current fault detection, and the proposed spaceborne protection system. It is noted that the intelligent remote power controller permits the implementation of digital relaying algorithms with both adaptive and programmable characteristics.

  2. Thermal Distribution System | Energy Systems Integration Facility | NREL

    Science.gov (United States)

    Thermal Distribution System Thermal Distribution System The Energy Systems Integration Facility's . Photo of the roof of the Energy Systems Integration Facility. The thermal distribution bus allows low as 10% of its full load level). The 60-ton chiller cools water with continuous thermal control

  3. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  4. Lactobacillus protects the integrity of intestinal epithelial barrier damaged by pathogenic bacteria

    Directory of Open Access Journals (Sweden)

    Qinghua eYu

    2015-03-01

    Full Text Available Pathogens invade intestinal mucosal barrier through phagocytosis of antigen presenting cells (dendritic cell, microfold cells, or through the invasion into the intestinal epithelial directly. Some pathogens could damage the cell junction between epithelial cells and use the paracellular pathway as an entrance to invade. Moreover, some Lactobacillus could inhibit the adhesion of the pathogens and protect the integrity of the cell junction and mucosal barrier. This research focused on the potential therapeutic effect of Lactobacillus fructosus (L. fructosus C2 to attenuate ETEC K88 or S. typhimurium SL1344 induced changes to mucosal barrier. The results demonstrated that treatment of polarized Caco-2 cells with L. fructosus C2 reduced the permeation of dextran, and expression of IL-8, p-ERK and p-JNK when cells were infected with pathogenic bacteria. The findings indicated that L. fructosus C2 exerted a protective effect against the damage to the integrity of Caco-2 cells by ETEC or S. typhimurium infection.

  5. Material Protection, Accounting, and Control Technologies (MPACT) Advanced Integration Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Durkee, Joe W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cipiti, Ben [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Demuth, Scott Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fallgren, Andrew James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jarman, Ken [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Li, Shelly [Argonne National Lab. (ANL), Argonne, IL (United States); Meier, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Miller, Mike [Argonne National Lab. (ANL), Argonne, IL (United States); Osburn, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Dasari, Venkateswara Rao [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ticknor, Lawrence O. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yoo, Tae-Sic [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-30

    The development of sustainable advanced nuclear fuel cycles is a long-term goal of the Office of Nuclear Energy’s (DOE-NE) Fuel Cycle Technologies program. The Material Protection, Accounting, and Control Technologies (MPACT) campaign is supporting research and development (R&D) of advanced instrumentation, analysis tools, and integration methodologies to meet this goal (Miller, 2015). This advanced R&D is intended to facilitate safeguards and security by design of fuel cycle facilities. The lab-scale demonstration of a virtual facility, distributed test bed, that connects the individual tools being developed at National Laboratories and university research establishments, is a key program milestone for 2020. These tools will consist of instrumentation and devices as well as computer software for modeling, simulation and integration.

  6. Material Protection, Accounting, and Control Technologies (MPACT) Advanced Integration Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Mike [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cipiti, Ben [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Demuth, Scott Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Durkee, Jr., Joe W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fallgren, Andrew James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jarman, Ken [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Li, Shelly [Idaho National Lab. (INL), Idaho Falls, ID (United States); Meier, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Osburn, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Dasari, Venkateswara Rao [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ticknor, Lawrence O. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yoo, Tae-Sic [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-30

    The development of sustainable advanced nuclear fuel cycles is a long-term goal of the Office of Nuclear Energy’s (DOE-NE) Fuel Cycle Technologies program. The Material Protection, Accounting, and Control Technologies (MPACT) campaign is supporting research and development (R&D) of advanced instrumentation, analysis tools, and integration methodologies to meet this goal (Miller, 2015). This advanced R&D is intended to facilitate safeguards and security by design of fuel cycle facilities. The lab-scale demonstration of a virtual facility, distributed test bed, that connects the individual tools being developed at National Laboratories and university research establishments, is a key program milestone for 2020. These tools will consist of instrumentation and devices as well as computer software for modeling, simulation and integration.

  7. QUANTITATIVE СHARACTERISTICS OF COMPLEMENTARY INTEGRATED HEALTH CARE SYSTEM AND INTEGRATED MEDICATION MANAGEMENT INFORMATION SYSTEM

    Directory of Open Access Journals (Sweden)

    L. Yu. Babintseva

    2015-05-01

    i mportant elements of state regulation of the pharmaceutical sector health. For the first time creation of two information systems: integrated medication management infor mation system and integrated health care system in an integrated medical infor mation area, operating based on th e principle of complementarity was justified. Global and technological coefficients of these systems’ functioning were introduced.

  8. Annexes to the lecture on reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The present paper deals with the fundamentals for a reactor protection system and discusses the following topics: - System lay-out - Analog measured data acquisition - Analog measured data processing - Limit value generation and logical gating - Procesing of the reactor protection actuation signals - Decoupling of the reactor protection system - Mechanical lay-out - Monitoring system and - Emergency control station. (orig./RW)

  9. Electrical Power Systems Protection and Interdependencies with ICT

    OpenAIRE

    Milis, George; Kyriakides, Elias; Hadjiantonis, Antonis

    2017-01-01

    The present chapter discusses the issue of protection of the electrical power systems, addressing all dimensions, from the need of protection to the identified faults and disturbances to the available protection schemes and further considerations, also looking at the challenges brought by recognizing the interdependent nature of the today’s electrical power systems.

  10. Fire protection in ventilation systems and in case of fire operating ventilation systems

    International Nuclear Information System (INIS)

    Zitzelsberger, J.

    1983-01-01

    The fire risks in ventilation systems are discussed. It follows a survey of regulations on fire prevention and fire protection in ventilation systems and smoke and heat exhaust systems applicable to nuclear installations in the Federal Republic of Germany. Fire protection concepts for normal systems and for systems operating also in case of fire will be given. Several structural elements for fire protection in those systems will be illustrated with regard to recent research findings

  11. Angle Control-Based Multi-Terminal Out-of-Step Protection System

    OpenAIRE

    Antans Sauhats; Andrejs Utans; Dmitrijs Antonovs; Andrejs Svalovs

    2017-01-01

    From time to time a sequence of unexpected and overlapping contingencies may lead to power system angular instability and even blackouts if not addressed adequately by means of an out-of-step (OOS) protection system. The motivation of the paper is an attempt to develop a workable prototype of the OOS protection system. The deficiencies of the protection currently used in the Latvian Power System network are highlighted and a new protection structure is proposed. The protection system comprise...

  12. DLP-systems: Protection from Insiders

    Directory of Open Access Journals (Sweden)

    Ivan Sergeevich Boridko

    2013-02-01

    Full Text Available In the paper the necessity of further introduction of modern systems of information protection against internal leaks, including DLP-systems, is justified. The issues of development of training specialists in the field of information security is considered.

  13. 14 CFR 25.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 25.954...

  14. 14 CFR 27.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 27.954...

  15. 14 CFR 29.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 29.954...

  16. 14 CFR 23.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 23.954... Fuel System § 23.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a...

  17. Integration of reusable systems

    CERN Document Server

    Rubin, Stuart

    2014-01-01

    Software reuse and integration has been described as the process of creating software systems from existing software rather than building software systems from scratch. Whereas reuse solely deals with the artifacts creation, integration focuses on how reusable artifacts interact with the already existing parts of the specified transformation. Currently, most reuse research focuses on creating and integrating adaptable components at development or at compile time. However, with the emergence of ubiquitous computing, reuse technologies that can support adaptation and reconfiguration of architectures and components at runtime are in demand. This edited book includes 15 high quality research papers written by experts in information reuse and integration to cover the most recent advances in the field. These papers are extended versions of the best papers which were presented at IEEE International Conference on Information Reuse and Integration and IEEE International Workshop on Formal Methods Integration, which wa...

  18. Advanced nuclear control and protection system ANCAP-80

    International Nuclear Information System (INIS)

    Asai, Takashi; Okano, Michihiko; Ishibashi, Kengo; Hasegawa, Masakoto; Fukuda, Hiroyoshi; Hosomichi, Renichi.

    1983-01-01

    Advanced reactor protection systems were developed to improve operational reliability and availability and to ease the burden of operators of Mitsubishi PWR Nuclear Power Stations. (Called ANCAP-80; Advanced Nuclear Control And Protection System) For the PWR plants now being planned and in future plans, Mitsubishi will adopt these systems with the following functional features; (1) Four channel protection logic, (2) Automatic bypass logic, (3) Automatic test provision, (4) Optical isolators. (author)

  19. A protection system of low temperature thermo-supply nuclear reactor

    International Nuclear Information System (INIS)

    Jiang Binsen

    1988-09-01

    A Protection system of low temperature thermo-supply nuclear reactor is introduced. It is the first protection system, which is designed and manufactred on the basis of Chinese National Standard GB 4083-83 'General Safety Principle of Nuclear Reactor Protection System', to be considered under the circumstances of industry level in China. Advantages of the protection system are as follows: 1)The single failure criteria can fully be fulfilled by the protection system. 2) On-line testing system can be used for detecting all of failure components and quick identifying the failure points in the system. 3) It is convenience for maintenacnce of the system. To complete this project is very important and helpful in promoting the development of the protection system and safety operation of nuclear reactor in China

  20. Role of materials accounting in integrated safeguards systems for reprocessing plants

    International Nuclear Information System (INIS)

    Hakkila, E.A.; Gutmacher, R.G.; Markin, J.T.; Shipley, J.P.; Whitty, W.J.

    1981-01-01

    Integration of materials accounting and containment/surveillance techniques for international safeguards requires careful examination and definition of suitable inspector activities for verification of operator's materials accounting data. The inspector's verification procedures are designed to protect against data falsification and/or the use of measurement uncertainties to conceal missing material. Materials accounting activities are developed to provide an effective international safeguards system when combined with containment/surveillance activities described in a companion paper

  1. Pipeline protection with multi component liquid polyurethane coating systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuprion, Rainer; Hornig, Maja [TIB Chemicals Ag, Mannheim (Germany)

    2009-07-01

    Protective coating systems are one of the major defence mechanisms against corrosion for transmission pipelines, pipes within a refinery or petrochemical processing facilities. More and more pipelines are being constructed for the supply and transmission of gas and oil, each year but, in addition many existing pipelines are approaching an age where inspection reveals the necessity to consider complete refurbishment. However, the number of rehabilitation projects each year is still relatively small. Therefore, in the coming years, a rising need and necessity can be expected, for the owners and operating companies to be faced with the option of either replacing the pipeline or refurbishing of the existing pipeline. If the pipeline is known to have external corrosion, then safe and economic operation should be assured. Rehabilitation should be done before it is too late in order to ensure its future integrity and operational life. Rehabilitation of pipelines has been both the economic solution and, more significantly, the ecological solution and in many of those cases the coatings selected for the external protection has been multi component liquids based on 100% solids polyurethanes. (author)

  2. Reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The safety concept requires to ensure that - the reactor protection system - the active engineered safeguard - and the necessary auxiliary systems are so designed and interfaced in respect of design and mode of action that, in the event of single component failure reliable control of the consequences of accidents remains ensured at all times and that the availability of the power plant is not limited unnecessarily. In order to satisfy these requirements due, importance was attached to a consistent spacial separation of the mutually redundant subsystems of the active safety equipment. The design and layout of the reactor protection system, of the power supply (emergency power supply), and of the auxiliary systems important from the safety engineering point of view, are such that their subsystems also largely satisfy the requirements of independence and spacial separation. (orig./RW)

  3. Design and implementation of an advanced protection system for the Shin-Kori 3 and 4 nuclear power plant

    International Nuclear Information System (INIS)

    Kim, Yonghak; Choi, Woongseock; Kwon, Jongsoo; Wilkosz, Stephen J.; Ridolfo, Charles F.; Yanosy, Paul L.

    2008-01-01

    The Nuclear Power Industry is currently embracing modern digital technology for upgrades to existing Instrumentation and Control (I and C) infrastructures as well as for incorporation into the next generation of new plants which will be coming 'on-line' during the next decade. This technology is being fully exploited for the next generation of advanced plant protection systems which will be initially deployed on the Shin-Kori 3 and 4 Nuclear Power Plant in the Republic of Korea. The system design for this plant protection system is being performed by the Korea Power Engineering Company (KOPEC) and builds upon the past generation of digital safety systems which were initially implemented at Ulchin 5 and 6. The advanced protection system is an evolution of this existing design and includes a number of improved operating attributes including: · Integration of Reactor Protection, Engineered Safety Features Actuation, and Qualified Indication and Alarm functions which were previously implemented by separate systems in the past. · Use of a 'soft control' interface which provides convenient accessibility to the safety systems from 'operator workstations' · Implementation of a Large Display Panel (LDP) which provides a consistent and constant representation of the overall plant state and of the plant safety status. The equipment for the advanced plant protection system is being provided by Westinghouse Electric Company (WEC) and utilizes the Westinghouse 'Common Q' Standardized qualified platform (where 'Q' denotes 'qualified'). The 'Common Q' platform is comprised of commercially dedicated Programmable Logic Controllers (PLC's), color-graphic Flat Panel Displays (FPD's) with integral touch screens, and high speed data communication links. It is a mature product that is in wide use for a number of safety-related applications. Among its key attributes are: · High overall system availability, which is achieved via use of a multiple channel configuration that is tolerant

  4. A SYSTEM APPROACH TO ORGANISING PROTECTION FROM TARGETED INFORMATION IN SOCIAL NETWORKS

    Directory of Open Access Journals (Sweden)

    Marina V. Tumbinskaya

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the study is to formalise a generalised algorithm for the distribution of targeted information in social networks, serving as the basis for a methodology for increasing personal information security. Method The research is based on the methodology of protection from unwanted information distributed across social network systems. Results The article presents the formalisation of an algorithm for the distribution of targeted information across social networks: input and output parameters are defined and the algorithm’s internal conditions are described, consisting of parameters for implementing attack scenarios, which variation would allow them to be detailed. A technique for protection from targeted information distributed across social networks is proposed, allowing the level of protection of personal data and information of social networks users to be enhanced, as well as the reliability of information increased. Conclusion The results of the research will help to prevent threats to information security, counteract attacks by intruders who often use methods of competitive intelligence and social engineering through the use of countermeasures. A model for protection against targeted information and implement special software for its integration into online social network social information systems is developed. The system approach will allow external monitoring of events in social networks to be carried out and vulnerabilities identified in the mechanisms of instant messaging, which provide opportunities for attacks by intruders. The results of the research make it possible to apply a network approach to the study of informal communities, which are actively developing today, at a new level. 

  5. Fluor Hanford Integrated Safety Management System Phase II Verification Vol 1 & Vol 2

    Energy Technology Data Exchange (ETDEWEB)

    PARSONS, J.E.

    2000-07-15

    The U.S. Department of Energy (DOE) is committed to conducting work efficiently and in a manner that ensures protection of the workers, public, and environment. DOE policy mandates that safety management systems be used to systematically integrate safety into management and work practices at all levels while accomplishing mission goals in an effective and efficient manner. The purpose of the Fluor Hanford (FH) Integrated Safety Management System (ISMS) verification was to determine whether FH's ISM system and processes are sufficiently implemented to accomplish the goal of ''Do work safely.'' The purpose of the DOE, Richland Operations Office (RL) verification was to determine whether RL has established processes that adequately describe RL's role in safety management and if those processes are sufficiently implemented.

  6. Design and performance evaluation of collision protection-based safety operation for a haptic robot-assisted catheter operating system.

    Science.gov (United States)

    Zhang, Linshuai; Guo, Shuxiang; Yu, Huadong; Song, Yu; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori

    2018-02-23

    The robot-assisted catheter system can increase operating distance thus preventing the exposure radiation of the surgeon to X-ray for endovascular catheterization. However, few designs have considered the collision protection between the catheter tip and the vessel wall. This paper presents a novel catheter operating system based on tissue protection to prevent vessel puncture caused by collision. The integrated haptic interface not only allows the operator to feel the real force feedback, but also combines with the newly proposed collision protection mechanism (CPM) to mitigate the collision trauma. The CPM can release the catheter quickly when the measured force exceeds a certain threshold, so as to avoid the vessel puncture. A significant advantage is that the proposed mechanism can adjust the protection threshold in real time by the current according to the actual characteristics of the blood vessel. To verify the effectiveness of the tissue protection by the system, the evaluation experiments in vitro were carried out. The results show that the further collision damage can be effectively prevented by the CPM, which implies the realization of relative safe catheterization. This research provides some insights into the functional improvements of safe and reliable robot-assisted catheter systems.

  7. NSTX Protection And Interlock Systems For Coil And Powers Supply Systems

    International Nuclear Information System (INIS)

    Zhao, X.; Ramakrishnan, S.; Lawson, J.; Neumeyer, C.; Marsala, R.; Schneider, H.

    2009-01-01

    NSTX at Princeton Plasma Physics Laboratory (PPPL) requires sophisticated plasma positioning control system for stable plasma operation. TF magnetic coils and PF magnetic coils provide electromagnetic fields to position and shape the plasma vertically and horizontally respectively. NSTX utilizes twenty six coil power supplies to establish and initiate electromagnetic fields through the coil system for plasma control. A power protection and interlock system is utilized to detect power system faults and protect the TF coils and PF coils against excessive electromechanical forces, overheating, and over current. Upon detecting any fault condition the power system is restricted, and it is either prevented from initializing or suppressed to de-energize coil power during pulsing. Power fault status is immediately reported to the computer system. This paper describes the design and operation of NSTX's protection and interlocking system and possible future expansion.

  8. System and method for quench protection of a superconductor

    Science.gov (United States)

    Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas

    2008-03-11

    A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.

  9. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  10. A New Physical Protection System Design and Evaluation Process

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Kim, Myungsu; Bae, Yeongkyoung; Na, Janghwan [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    International Atomic Energy Agency(IAEA) had established security-related department and has been strengthening security measures against possible sabotage. IAEA enforces the recommendations for the physical protection of NPPs in the INFCIRC/ 225/Rev.5 to the member states and U.S. NRC also enforces the similar requirements in 10 CFR 73.55. Thus, in order to let Korean NPPs meet the new requirements in INFCIRC/225/Rev.5 or U.S. NRC requirements, Korea nuclear licensee should develop or establish appropriate physical protection system (PPS) design methods for the physical protection of the operating NPPs and new NPPs. KHNP is doing the project of 'Development of APR1400 Physical Protection System Design (2012- 2015, KHNP/KAERI /KEPCO E-C)'. This paper describes overview of a physical protection system (PPS) design and evaluation for an advanced nuclear power plant. It found that a new physical protection system (PPS)design and evaluation. KHNP is doing the project of Physical Protection System design according to U.S. NRC requirements and IAEA requirements in INFCIRC /225 /Rev.5 and will complete by 7.31, 2015 for development of APR1400 Physical Protection System. After completing this project, the results of project are expected to apply new NPPs.

  11. Protecting integrated circuits from excessive charge accumulation during plasma cleaning of multichip modules

    Science.gov (United States)

    Rodenbeck, Christopher T; Girardi, Michael

    2015-04-21

    Internal nodes of a constituent integrated circuit (IC) package of a multichip module (MCM) are protected from excessive charge during plasma cleaning of the MCM. The protected nodes are coupled to an internal common node of the IC package by respectively associated discharge paths. The common node is connected to a bond pad of the IC package. During MCM assembly, and before plasma cleaning, this bond pad receives a wire bond to a ground bond pad on the MCM substrate.

  12. Tactical Systems Integration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Tactical Systems Integration Laboratory is used to design and integrate computer hardware and software and related electronic subsystems for tactical vehicles....

  13. Function integrated track system

    OpenAIRE

    Hohnecker, Eberhard

    2010-01-01

    The paper discusses a function integrated track system that focuses on the reduction of acoustic emissions from railway lines. It is shown that the combination of an embedded rail system (ERS), a sound absorbing track surface, and an integrated mini sound barrier has significant acoustic advantages compared to a standard ballast superstructure. The acoustic advantages of an embedded rail system are particularly pronounced in the case of railway bridges. Finally, it is shown that a...

  14. Smart systems integration and simulation

    CERN Document Server

    Poncino, Massimo; Pravadelli, Graziano

    2016-01-01

    This book-presents new methods and tools for the integration and simulation of smart devices. The design approach described in this book explicitly accounts for integration of Smart Systems components and subsystems as a specific constraint. It includes methodologies and EDA tools to enable multi-disciplinary and multi-scale modeling and design, simulation of multi-domain systems, subsystems and components at all levels of abstraction, system integration and exploration for optimization of functional and non-functional metrics. By covering theoretical and practical aspects of smart device design, this book targets people who are working and studying on hardware/software modelling, component integration and simulation under different positions (system integrators, designers, developers, researchers, teachers, students etc.). In particular, it is a good introduction to people who have interest in managing heterogeneous components in an efficient and effective way on different domains and different abstraction l...

  15. The strategy for intelligent integrated instrumentation and control system development

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Ham, Chang Shik

    1995-01-01

    All of the nuclear power plants in Korea are operating with analog instrumentation and control ( I and C) equipment which are increasingly faced with frequent troubles, obsolescence and high maintenance expenses. Electrical and computer technology has improved rapidly in recent years and has been applied to other industries. So it is strongly recommended we adopt modern digital and computer technology to improve plant safety and availability. The advanced I and C system, namely, Integrated Intelligent Instrumentation and Control System (I 3 Cs) will be developed for beyond the next generation nuclear power plant. I 3 CS consists of three major parts, the advanced compact workstation, distributed digital control and protection system including Automatic Start-up/Shutdown Intelligent Control System (ASICS) and the computer-based alarm processing and operator support system, namely, Diagnosis, Response, and operator Aid Management System (DREAMS)

  16. Management information system applied to radiation protection services

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur

    2013-01-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  17. Management information system applied to radiation protection services

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur, E-mail: pabloag@cdtn.br, E-mail: lss@cdtn.br, E-mail: gmf@cdtn.br, E-mail: arthurqof@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  18. Future Interoperability of Camp Protection Systems (FICAPS)

    Science.gov (United States)

    Caron, Sylvie; Gündisch, Rainer; Marchand, Alain; Stahl, Karl-Hermann

    2013-05-01

    The FICAPS Project has been established as a Project of the European Defence Agency based on an initiative of Germany and France. Goal of this Project was to derive Guidelines, which by a proper implementation in future developments improve Camp Protection Systems (CPS) by enabling and improving interoperability between Camp Protection Systems and its Equipments of different Nations involved in multinational missions. These Guidelines shall allow for: • Real-time information exchange between equipments and systems of different suppliers and nations (even via SatCom), • Quick and easy replacement of equipments (even of different Nations) at run-time in the field by means of plug and play capability, thus lowering the operational and logistic costs and making the system highly available, • Enhancement of system capabilities (open and modular systems) by adding new equipment with new capabilities (just plug-in, automatic adjustment of the HMI Human Machine Interface) without costly and time consuming validation and test on system level (validation and test can be done on Equipment level), Four scenarios have been identified to summarize the interoperability requirements from an operational viewpoint. To prove the definitions given in the Guideline Document, a French and a German Demonstration System, based on existing national assets, were realized. Demonstrations, showing the capabilities given by the defined interoperability requirements with respect to the operational scenarios, were performed. Demonstrations included remote control of a CPS by another CPS, remote sensor control (Electro-Optic/InfraRed EO/IR) and remote effector control. This capability can be applied to extend the protection area or to protect distant infrastructural assets Demonstrations have been performed. The required interoperability functionality was shown successfully. Even if the focus of the FICAPS project was on camp protection, the solution found is also appropriate for other

  19. Fluor Hanford Integrated Safety Management System Phase II Verification Vol 1 and Vol 2

    CERN Document Server

    Parsons, J E

    2000-01-01

    The U.S. Department of Energy (DOE) is committed to conducting work efficiently and in a manner that ensures protection of the workers, public, and environment. DOE policy mandates that safety management systems be used to systematically integrate safety into management and work practices at all levels while accomplishing mission goals in an effective and efficient manner. The purpose of the Fluor Hanford (FH) Integrated Safety Management System (ISMS) verification was to determine whether FH's ISM system and processes are sufficiently implemented to accomplish the goal of ''Do work safely.'' The purpose of the DOE, Richland Operations Office (RL) verification was to determine whether RL has established processes that adequately describe RL's role in safety management and if those processes are sufficiently implemented.

  20. Fluor Hanford Integrated Safety Management System Phase II Verification Vol 1 and Vol 2

    International Nuclear Information System (INIS)

    PARSONS, J.E.

    2000-01-01

    The U.S. Department of Energy (DOE) is committed to conducting work efficiently and in a manner that ensures protection of the workers, public, and environment. DOE policy mandates that safety management systems be used to systematically integrate safety into management and work practices at all levels while accomplishing mission goals in an effective and efficient manner. The purpose of the Fluor Hanford (FH) Integrated Safety Management System (ISMS) verification was to determine whether FH's ISM system and processes are sufficiently implemented to accomplish the goal of ''Do work safely.'' The purpose of the DOE, Richland Operations Office (RL) verification was to determine whether RL has established processes that adequately describe RL's role in safety management and if those processes are sufficiently implemented

  1. Power system EMP protection. Final report

    International Nuclear Information System (INIS)

    Marable, J.H.; Barnes, P.R.; Nelson, D.B.

    1975-05-01

    Voltage transients induced in electric power lines and control circuits by the electromagnetic pulse (EMP) from high-altitude nuclear detonations may cause widespread power failure and damage in electric power systems. This report contains a parametric study of EMP power line surges and discusses protective measures to minimize their effects. Since EMP surges have considerably greater rates of rise than lightning surges, recommended standards and test procedures are given to assure that surge arresters protect equipment from damage by EMP. Expected disturbances and damage to power systems are reviewed, and actions are presented which distribution companies can take to counter them. These include backup communications methods, stockpiling of vulnerable parts, repair procedures, and dispatcher actions to prevent blackout from EMP-caused instabilities. A long-range program is presented for improving distributors' protection against EMP. This involves employee training, hardware protection for power and control circuits, and improvement of plans for emergency action. (U.S.)

  2. A Cause-Consequence Chart of a Redundant Protection System

    DEFF Research Database (Denmark)

    Nielsen, Dan Sandvik; Platz, O.; Runge, B.

    1975-01-01

    A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy of compone...... of components is taken into account. The possibility of using parameter variation as a basis for the choice of test policy is indicated.......A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy...

  3. Energy Systems Integration News | Energy Systems Integration Facility |

    Science.gov (United States)

    , utilities can operate more efficiently and profitably. That can increase the use of renewable energy sources challenge to utility companies, grid operators, and other stakeholders involved in wind energy integration recording is available from the July 16 webinar "Smart Grid Research at NREL's Energy Systems

  4. Duality for discrete integrable systems

    International Nuclear Information System (INIS)

    Quispel, G R W; Capel, H W; Roberts, J A G

    2005-01-01

    A new class of discrete dynamical systems is introduced via a duality relation for discrete dynamical systems with a number of explicitly known integrals. The dual equation can be defined via the difference of an arbitrary linear combination of integrals and its upshifted version. We give an example of an integrable mapping with two parameters and four integrals leading to a (four-dimensional) dual mapping with four parameters and two integrals. We also consider a more general class of higher-dimensional mappings arising via a travelling-wave reduction from the (integrable) MKdV partial-difference equation. By differencing the trace of the monodromy matrix we obtain a class of novel dual mappings which is shown to be integrable as level-set-dependent versions of the original ones

  5. Angle Control-Based Multi-Terminal Out-of-Step Protection System

    Directory of Open Access Journals (Sweden)

    Antans Sauhats

    2017-03-01

    Full Text Available From time to time a sequence of unexpected and overlapping contingencies may lead to power system angular instability and even blackouts if not addressed adequately by means of an out-of-step (OOS protection system. The motivation of the paper is an attempt to develop a workable prototype of the OOS protection system. The deficiencies of the protection currently used in the Latvian Power System network are highlighted and a new protection structure is proposed. The protection system comprises of several strategically located terminals, exchanging information in real time by means of a communication network. The OOS condition detection method is based on system-wide generation sources, electromotive forces, vectors, and angle control. The network splitting decision is based on generator coherence evaluation. Protection terminals determine online the groups of coherent generators and choose the splitting boundary from a predefined transmission lines (TLs cut sets list. The protection system structure, algorithm of operation, and possible IEC 61850 communication standard-based implementation are described.

  6. The Protective Arm of the Renin Angiotensin System (RAS)

    DEFF Research Database (Denmark)

    understanding of the protective side of the Renin Angiotensin System (RAS) involving angiotensin AT2 receptor, ACE2, and Ang(1-7)/Mas receptor Combines the knowledge of editors who pioneered research on the protective renin angiotensin system including; Dr. Thomas Unger, one of the founders of AT2 receptor......The Protective Arm of the Renin Angiotensin System: Functional Aspects and Therapeutic Implications is the first comprehensive publication to signal the protective role of a distinct part of the renin-angiotensin system (RAS), providing readers with early insight into a complex system which...... will become of major medical importance in the near future. Focusing on recent research, The Protective Arm of the Renin Angiotensin System presents a host of new experimental studies on specific components of the RAS, namely angiotensin AT2 receptors (AT2R), the angiotensin (1-7) peptide with its receptor...

  7. Agents in an Integrated System Architecture

    DEFF Research Database (Denmark)

    Hartvig, Susanne C; Andersen, Tom

    1997-01-01

    This paper presents research findings from development of an expert system and its integration into an integrated environment. Expert systems has proven hard to integrate because of their interactive nature. A prototype environment was developed using new integration technologies, and research...... findings concerning the use of OLE technology to integrate stand alone applications are discussed. The prototype shows clear advantages of using OLE technology when developing integrated environments....

  8. 75 FR 972 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-01-07

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... Federal, State and territorial marine protected area programs to join the National System of Marine Protected Areas. SUMMARY: NOAA and the Department of the Interior (DOI) invited Federal, State, commonwealth...

  9. Advanced safety management systems for maintenance of pipeline integrity

    International Nuclear Information System (INIS)

    Borysiewicz, M.; Potempski, S.

    2005-01-01

    One of the duties of the pipeline's operator is to introduce means for protection of human safety and the environment. This should be reflected in preparation of comprehensive Risk Management System with its key element Activity Programme for Management of Pipeline Integrity. In the paper such programme has been described taking into account law regulations and practical activities undertaken in technologically advanced countries (mainly USA and EU), where such solutions are implemented in routine operations. Possible solutions of realization of all elements of the programme, as well as information on utilization of computer aided support have been also included. (authors)

  10. Discussion on radiation protection system from ethical issues

    International Nuclear Information System (INIS)

    Li, Xutong; Guo, Qiuju

    2002-01-01

    This paper discussed the relationship between radiation protection system and ethical principle, viz. equity and efficiency. According to the authors' opinions, the main problem that the system of radiation protection facing now is the dose-limitation principle cannot incarnate the equity principle completely. Even though the distinguishing between practice and intervention is no other than solving the problem, but the scheme is not perfect still. Ethical issues should be given more attention and be more researched when we try to modify the radiation protection system today

  11. Confidentiality and integrity in crowdsourcing systems

    CERN Document Server

    Ranj Bar, Amin

    2014-01-01

    Confidentiality and Integrity in Crowdsourcing Systems focuses on identity, privacy, and security related issues in crowdsourcing systems and in particular the confidentiality and integrity of online data created via crowdsourcing. This book begins with an introduction to crowdsourcing and then covers the privacy and security challenges of Confidentiality. The book examines integrity in these systems and the management and control of crowdsourcing systems.

  12. Mutual influences of rated currents, short circuit levels, fault durations and integrated protective schemes for industrial distribution MV switchgears

    Energy Technology Data Exchange (ETDEWEB)

    Gaidano, G. (FIAT Engineering, Torino, Italy); Lionetto, P.F.; Pelizza, C.; Tommazzolli, F.

    1979-01-01

    This paper deals with the problem of integrated and coordinated design of distribution systems, as regards the definition of system structure and parameters together with protection criteria and schemes. Advantages in system operation, dynamic response, heavier loads with reduced machinery rating margins and overall cost reduction, can be achieved. It must be noted that MV switchgears installed in industrial main distribution substations are the vital nodes of the distribution system. Very large amounts of power (up to 100 MW and more) are conveyed through MV busbars, coming from Utility and from in-plant generators and outgoing to subdistribution substations, to step-down transformers and to main concentrated loads (big drivers, furnaces etc.). Criteria and methods already studied and applied to public distribution are examined to assess service continuity and economics by means of the reduction of thermal stresses, minimization of disturbances and improvement of system stability. The life of network components depends on sizing, on fault energy levels and on probability of fault occurrence. Constructional measures and protection schemes, which reduce probability and duration of faults, are the most important tools to improve overall reliability. The introduction of advanced techniques, mainly based on computer application, not only allows drastic reduction of fault duration, but also permits the system to operate, under any possible contingency, in the optimal conditions, as the computer provides adaptive control. This mode of system management makes it possible to size network components with reference to the true magnitude of system quantities, avoiding expensive oversizing connected to the unflexibility of conventional protection and control schemes.

  13. Physical protection of nuclear installations

    International Nuclear Information System (INIS)

    Toepfer, K.

    1989-01-01

    This contribution investigates the possible danger and the legal basis of physical protection and explains the current, integrated system provided for, as well as the underlying possible scenarios of an assault: (1) by a violent crowd of aggressors outside the installation, (2) by a small group of aggressors outside the installation, (3) by a person allowed to enter (internal assault). The physical protection system supplements the internal safety measures to enhance protection against hypothetical and possible acts of terrorism or other criminal assault. The system covers external and internal controlled areas, access monitoring, physical protection control room and service, security checks of the personnel, and activities to disclose sabotage. Some reflections on the problem field between security controls and the constitutional state conclude this contribution. (orig./HSCH) [de

  14. Remotely Piloted Aircraft Systems (RPAS) for high resolution topography and monitoring: civil protection purposes on hydrogeological contexts

    Science.gov (United States)

    Bertacchini, Eleonora; Castagnetti, Cristina; Corsini, Alessandro; De Cono, Stefano

    2014-10-01

    The proposed work concerns the analysis of Remotely Piloted Aircraft Systems (RPAS), also known as drones, UAV (Unmanned Aerial Vehicle) or UAS (Unmanned Aerial System), on hydrogeological contexts for civil protection purposes, underlying the advantages of using a flexible and relatively low cost system. The capabilities of photogrammetric RPAS multi-sensors platform were examined in term of mapping, creation of orthophotos, 3D models generation, data integration into a 3D GIS (Geographic Information System) and validation through independent techniques such as GNSS (Global Navigation Satellite System). The RPAS used (multirotor OktoXL, of the Mikrokopter) was equipped with a GPS (Global Positioning System) receiver, digital cameras for photos and videos, an inertial navigation system, a radio device for communication and telemetry, etc. This innovative way of viewing and understanding the environment showed huge potentialities for the study of the territory, and due to its characteristics could be well integrated with aircraft surveys. However, such characteristics seem to give priority to local applications for rigorous and accurate analysis, while it remains a means of expeditious investigation for more extended areas. According to civil protection purposes, the experimentation was carried out by simulating operational protocols, for example for inspection, surveillance, monitoring, land mapping, georeferencing methods (with or without Ground Control Points - GCP) based on high resolution topography (2D and 3D information).

  15. Evaluation of the integrity of radiological protection clothing used in veterinary radiology

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Paola da Costa; Barros, Frieda Saicla; Costa, Douglas Siqueira da, E-mail: paah_dacosta@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Curso Superior de Tecnologia em Radiologia e Programa de Pos-Graduacao em Engenharia Biomedica

    2017-11-01

    This study aimed to evaluate the integrity of radiological protection clothing used by veterinarians in veterinary radiology facilities, and whether they are available in an adequate quantity for the team. Inspection was performed by palpation, followed by X-ray scanning in 189 clothing from 29 veterinary facilities. The results indicate that 5% of the clothes evaluated in this study were considered inadequate due to the failure of the integrity of the lead, being most lead aprons. All facilities have at least two lead aprons and one Thyroid protectors. 24% of the facilities have lead glasses, pointing to a risk to veterinarians by radiosensitivity of the eyes. Also, 24% of the facilities do not have lead gloves, which also presents a risk due to the hand's exposure to the primary beam. Most lead clothing has shield equivalence of 0.5mmPb. The method used in the study was effective in attesting the adequacy of lead clothing. It is recommended to periodically evaluate clothing to ensure that users are always protected. (author)

  16. Evaluation of the integrity of radiological protection clothing used in veterinary radiology

    International Nuclear Information System (INIS)

    Rosa, Paola da Costa; Barros, Frieda Saicla; Costa, Douglas Siqueira da

    2017-01-01

    This study aimed to evaluate the integrity of radiological protection clothing used by veterinarians in veterinary radiology facilities, and whether they are available in an adequate quantity for the team. Inspection was performed by palpation, followed by X-ray scanning in 189 clothing from 29 veterinary facilities. The results indicate that 5% of the clothes evaluated in this study were considered inadequate due to the failure of the integrity of the lead, being most lead aprons. All facilities have at least two lead aprons and one Thyroid protectors. 24% of the facilities have lead glasses, pointing to a risk to veterinarians by radiosensitivity of the eyes. Also, 24% of the facilities do not have lead gloves, which also presents a risk due to the hand's exposure to the primary beam. Most lead clothing has shield equivalence of 0.5mmPb. The method used in the study was effective in attesting the adequacy of lead clothing. It is recommended to periodically evaluate clothing to ensure that users are always protected. (author)

  17. Electrostatic protection of the solar power satellite and rectenna. Part 2: Lightning protection of the rectenna

    Science.gov (United States)

    1980-01-01

    Computer simulations and laboratory tests were used to evaluate the hazard posed by lightning flashes to ground on the Solar Power Satellite rectenna and to make recommendations on a lightning protection system for the rectenna. The distribution of lightning over the lower 48 of the continental United States was determined, as were the interactions of lightning with the rectenna and the modes in which those interactions could damage the rectenna. Lightning protection was both required and feasible. Several systems of lightning protection were considered and evaluated. These included two systems that employed lightning rods of different lengths and placed on top of the rectenna's billboards and a third, distribution companies; it consists of short lightning rods all along the length of each billboard that are connected by a horizontal wire above the billboard. The distributed lightning protection system afforded greater protection than the other systems considered and was easier to integrate into the rectenna's structural design.

  18. A High-Power Wireless Charging System Development and Integration for a Toyota RAV4 Electric Vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Onar, Omer C [ORNL; Seiber, Larry Eugene [ORNL; White, Cliff P [ORNL; Chinthavali, Madhu Sudhan [ORNL; Campbell, Steven L [ORNL

    2016-01-01

    Several wireless charging methods are underdevelopment or available as an aftermarket option in the light-duty automotive market. However, there are not many studies detailing the vehicle integrations, particularly a complete vehicle integration with higher power levels. This paper presents the development, implementation, and vehicle integration of a high-power (>10 kW) wireless power transfer (WPT)-based electric vehicle (EV) charging system for a Toyota RAV4 vehicle. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction (PFC), high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, communications, and protection systems are also presented in addition to the alignment and the driver interface system. The physical limitations of the system are also defined that would prevent the system operating at higher levels. The experiments are carried out using the integrated vehicle and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies with matched and interoperable primary and secondary coils.

  19. Power system protection 1 principles and components

    CERN Document Server

    Association, Electricity Training

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  20. CONCERT. ''European joint programme for the integration of radiation protection research''; CONCERT. Gemeinsame Europaeische Forschungsfoerderung

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt-Hannig, A.; Birschwilks, M.; Jung, T. [Bundesamt fuer Strahlenschutz (Germany)

    2016-07-01

    CONCERT is a joint project of the EU and its member states which assume joint financing: Over the next five years the largest European radiation protection programme so far will have available about 28 Million Euros for research and integrative measures, whereby the European Commission will bear 70 per cent of the costs. Integrative measures include, among others, targeted vocational education and training of junior researchers in radiation protection, better access to research and irradiation facilities for scientists, as well as a stronger connection of universities and research centres in radiation protection research.

  1. Human-Systems Integration Processes

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to baseline a Human-Systems Integration Processes (HSIP) document as a companion to the NASA-STD-3001 and Human Integration Design...

  2. Systems Engineering and Integration for Advanced Life Support System and HST

    Science.gov (United States)

    Kamarani, Ali K.

    2005-01-01

    Systems engineering (SE) discipline has revolutionized the way engineers and managers think about solving issues related to design of complex systems: With continued development of state-of-the-art technologies, systems are becoming more complex and therefore, a systematic approach is essential to control and manage their integrated design and development. This complexity is driven from integration issues. In this case, subsystems must interact with one another in order to achieve integration objectives, and also achieve the overall system's required performance. Systems engineering process addresses these issues at multiple levels. It is a technology and management process dedicated to controlling all aspects of system life cycle to assure integration at all levels. The Advanced Integration Matrix (AIM) project serves as the systems engineering and integration function for the Human Support Technology (HST) program. AIM provides means for integrated test facilities and personnel for performance trade studies, analyses, integrated models, test results, and validated requirements of the integration of HST. The goal of AIM is to address systems-level integration issues for exploration missions. It will use an incremental systems integration approach to yield technologies, baselines for further development, and possible breakthrough concepts in the areas of technological and organizational interfaces, total information flow, system wide controls, technical synergism, mission operations protocols and procedures, and human-machine interfaces.

  3. 78 FR 44475 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-07-24

    ... that the performance or product has some reliability-related value, then the requirement will have...] Protection System Maintenance Reliability Standard AGENCY: Federal Energy Regulatory Commission, Energy... Commission proposes to approve a revised Reliability Standard, PRC-005- 2--Protection System Maintenance, to...

  4. Integration of LDSE and LTVS logs with HIPAA compliant auditing system (HCAS)

    Science.gov (United States)

    Zhou, Zheng; Liu, Brent J.; Huang, H. K.; Guo, Bing; Documet, Jorge; King, Nelson

    2006-03-01

    The deadline of HIPAA (Health Insurance Portability and Accountability Act) Security Rules has passed on February 2005; therefore being HIPAA compliant becomes extremely critical to healthcare providers. HIPAA mandates healthcare providers to protect the privacy and integrity of the health data and have the ability to demonstrate examples of mechanisms that can be used to accomplish this task. It is also required that a healthcare institution must be able to provide audit trails on image data access on demand for a specific patient. For these reasons, we have developed a HIPAA compliant auditing system (HCAS) for image data security in a PACS by auditing every image data access. The HCAS was presented in 2005 SPIE. This year, two new components, LDSE (Lossless Digital Signature Embedding) and LTVS (Patient Location Tracking and Verification System) logs, have been added to the HCAS. The LDSE can assure medical image integrity in a PACS, while the LTVS can provide access control for a PACS by creating a security zone in the clinical environment. By integrating the LDSE and LTVS logs with the HCAS, the privacy and integrity of image data can be audited as well. Thus, a PACS with the HCAS installed can become HIPAA compliant in image data privacy and integrity, access control, and audit control.

  5. Integrated design for space transportation system

    CERN Document Server

    Suresh, B N

    2015-01-01

    The book addresses the overall integrated design aspects of a space transportation system involving several disciplines like propulsion, vehicle structures, aerodynamics, flight mechanics, navigation, guidance and control systems, stage auxiliary systems, thermal systems etc. and discusses the system approach for design, trade off analysis, system life cycle considerations, important aspects in mission management, the risk assessment, etc. There are several books authored to describe the design aspects of various areas, viz., propulsion, aerodynamics, structures, control, etc., but there is no book which presents space transportation system (STS) design in an integrated manner. This book attempts to fill this gap by addressing systems approach for STS design, highlighting the integrated design aspects, interactions between various subsystems and interdependencies. The main focus is towards the complex integrated design to arrive at an optimum, robust and cost effective space transportation system. The orbit...

  6. Regulatory System of Radiation Protection in Taiwan

    International Nuclear Information System (INIS)

    Tang, F. T.; Huang, C. C.

    2004-01-01

    After the radioactive contaminated buildings incident occurred in Taiwan in 1993, the competent authority for radiation protection the Atomic Energy Council (AEC) started to review the structured problem of radiation protection regulatory system. Through several years' investigation and study, the AEC has improved two important tools in radiation protection regulatory system, i.e., control regulations and actual practice, and made them more rigorous and efficient. This paper will make a brief introduction of the efforts that Taiwan has made in this respect. Taiwan's radiation protection control was based on the Atomic Energy Law promulgated in 1968, but the control idea and authorization scope were not sufficient to appropriately respond to the highly developed economy and democracy in Taiwan. After several years' legislative process, the Ionizing Radiation Protection Law (IRP Law) was promulgated and entered into force on February 1, 2003. This IRP Law specifically emphasizes categorized risk management of radiation sources, establishment of personnel licenses and training system, enhancement of public safety control, and implementation of quality assurance program for medical exposure. The Legislative Yuan (Congress) fully authorized the competent authority to establish various technological control regulations according to control necessity without prior review by the Legislative Yuan in advance. As to the penalties of the violations of the IRP Law, the AEC adopts high-rated administrative fines and applies the Criminal Law to those who seriously contaminate the environment. In actual practice, the AEC has constructed a Radiation Protection Control Information System compatible with the IRP Law that fully combines the functions of computers and Internet. The information of facility operators who own radiation sources, radiation protection specialists, and operating personnel are entered into this system, starting from the submission of application of the

  7. Adaptive Integration of Nonsmooth Dynamical Systems

    Science.gov (United States)

    2017-10-11

    2017 W911NF-12-R-0012-03: Adaptive Integration of Nonsmooth Dynamical Systems The views, opinions and/or findings contained in this report are those of...Integration of Nonsmooth Dynamical Systems Report Term: 0-Other Email: drum@gwu.edu Distribution Statement: 1-Approved for public release; distribution is...classdrake_1_1systems_1_1_integrator_base.html ; 3) a solver for dynamical systems with arbitrary unilateral and bilateral constraints (the key component of the time stepping systems )- see

  8. Integrated audit in labour, health and environmental protection in RAG Deutsche Steinkohle AG; Das integrierte Audit im Arbeits-, Gesundheits- und Umweltschutz bei der RAG Deutsche Steinkohle AG

    Energy Technology Data Exchange (ETDEWEB)

    Jaensch, Christian [Zentralbereich Arbeits-, Gesundheits- und Umweltschutz, RAG Aktiengesellschaft, Herne (Germany)

    2009-07-02

    On the basis of the experience acquired with the environmental audit at RAG the internal audit was extended by the safety at work and health protection fields. This approach is the logical adaptation to the development of the integrated management system in labour, health and environmental protection (LHE), which is specified in the internal RAG LHE concept. The audit serves essentially for regular and systematic checking of the management process in labour, health and environmental protection. The aims pursued with this integrated audit and also the course of an audit are explained. In addition the special requirements both on an audit in a mining company and also on own auditors are outlined. This internal check has been carried out in all RAG Deutsche Steinkohle companies since 2008. (orig.)

  9. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  10. Frequency domain analysis of lightning protection using four lightning protection rods

    Directory of Open Access Journals (Sweden)

    Javor Vesna

    2008-01-01

    Full Text Available In this paper the lightning discharge channel is modeled as a vertical monopole antenna excited by a pulse generator at its base. The lightning electromagnetic field of a nearby lightning discharge in the case of lightning protection using four vertical lightning protection rods was determined in the frequency domain. Unknown current distributions were determined by numerical solving of a system of integral equations of two potentials using the Point Matching Method and polynomial approximation of the current distributions. The influence of the real ground, treated as homogeneous loss half-space of known electrical parameters, expressed through a Sommerfeld integral kernel, was modeled using a new Two-image approximation which gives good results in both near and far fields.

  11. One System Integrated Project Team Progress in Coordinating Hanford Tank Farms and the Waste Treatment Plant

    International Nuclear Information System (INIS)

    Skwarek, Raymond J.; Harp, Ben J.; Duncan, Garth M.

    2013-01-01

    The One System Integrated Project Team (IPT) was formed at the Hanford Site in late 2011 as a way to improve coordination and itegration between the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and the Tank Operations Contractor (TOC) on interfaces between the two projects, and to eliminate duplication and exploit opportunities for synergy. The IPT is composed of jointly staffed groups that work on technical issues of mutal interest, front-end design and project definition, nuclear safety, plant engineering system integration, commissioning, planning and scheduling, and environmental, safety, health and quality (ESH&Q) areas. In the past year important progress has been made in a number of areas as the organization has matured and additional opportunities have been identified. Areas covered in this paper include: Support for development of the Office of Envirnmental Management (EM) framework document to progress the Office of River Protection's (ORP) River Protection Project (RPP) mission; Stewardship of the RPP flowsheet; Collaboration with Savannah River Site (SRS), Savannah River National Laboratory (SRNL), and Pacific Northwest National Laboratory (PNNL); Operations programs integration; and, Further development of the waste acceptance criteria

  12. Design and evaluation of physical protection systems of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model.

  13. Criminal law repercussions on the Civil Protection System

    Science.gov (United States)

    Altamura, M.; Musso, L.

    2009-09-01

    The legal systems of our Countries provide the citizenship with a high level of protection. Personal safety and the protection of property are guaranteed by the State through organized structures among which we can include the Civil Protection. The progress of science and technology has greatly improved monitoring tools, currently used by the Civil Protection, which allow, to a certain extent, to predict and prevent risk and natural hazards. The assertion of an individual right, which in some cases has reached a constitutional rank, to benefit from Civil Protection services and the widespread perception throughout the citizenship of the competence of the system to prevent disasters, often causes people to take legal action against Civil Protection authorities should they fail in their duties to protect. However, the attempt of having both recognized an economic compensation for the suffered loss and the punishment of those whom misled, frequently undergoes criminal law. This process could have results that may jeopardize the effectiveness of Civil Protection service without meeting citizens’ demands. A dual effort is thus necessary in order to solve such a problem. On the one hand, an interdisciplinary knowledge needs to pervade criminal law in an attempt to relieve its self-referentiality and pretended supremacy. On the other hand an alternative, and more agile, system -such as civil or administrative law- has to be identified in order to respond to the legitimate requests for protection in the case of a faulty behaviour of the authorities.

  14. Integrating protection into food aid

    Directory of Open Access Journals (Sweden)

    Mariangela Bizzarri

    2007-01-01

    Full Text Available The World Food Programme (WFP does not have a specific protection mandate but its activities are increasingly shaped by awareness of the need to protect women and girls from sexual and gender-based violence (SGBV.

  15. GPK helmets protecting from gas and dusts

    Energy Technology Data Exchange (ETDEWEB)

    Il' inskii, Eh.G.; Kogan, Yu.A.; Mazanenko, V.P.

    1983-08-01

    The GPK protective helmet with an integrated respirator system protecting a miner's respiratory system and eyes from gases and dusts is described. The system uses compressed air from the mine compressed air system. Air is supplied to the respirator by an elastic rubber pipe to 30 m long. The air cools the miner's head under the helmet and passes between a protective shield and the miner's face protecting eyes and the respiratory system. Air supply ranges from 100 to 150 l/min. The air supplied to the respirator is cleaned by a filter. The GPK system weighs 1.2 kg. The system has been tested under laboratory conditions and in two coal mines under operational conditions at longwall faces and during mine drivage. Tests showed that the GPK guarantees efficient cooling and protection from dust. Design of the GPK helmet with a respirator is shown in two schemes. Technical specifications of the system are given.

  16. Distributed systems for protecting nuclear power stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-05-01

    The advantages of distributed control systems for the control of nuclear power stations are obviously of great interest. Some years ago, EPRI, (Electric Power Research Institute) showed that multiplexing the signals is technically feasible, that it enables the availability specifications to be met and costs to be reduced. Since then, many distributed control systems have been proposed by the manufacturers. This note offers some comments on the application of the distribution concept to protection systems -what should be distributed- and ends with a brief description of a protection system based on microprocessors for the pressurized power stations now being built in France [fr

  17. The near infrared imaging system for the real-time protection of the JET ITER-like wall

    Science.gov (United States)

    Huber, A.; Kinna, D.; Huber, V.; Arnoux, G.; Balboa, I.; Balorin, C.; Carman, P.; Carvalho, P.; Collins, S.; Conway, N.; McCullen, P.; Jachmich, S.; Jouve, M.; Linsmeier, Ch; Lomanowski, B.; Lomas, P. J.; Lowry, C. G.; Maggi, C. F.; Matthews, G. F.; May-Smith, T.; Meigs, A.; Mertens, Ph; Nunes, I.; Price, M.; Puglia, P.; Riccardo, V.; Rimini, F. G.; Sergienko, G.; Tsalas, M.; Zastrow, K.-D.; contributors, JET

    2017-12-01

    This paper describes the design, implementation and operation of the near infrared (NIR) imaging diagnostic system of the JET ITER-like wall (JET-ILW) plasma experiment and its integration into the existing JET protection architecture. The imaging system comprises four wide-angle views, four tangential divertor views, and two top views of the divertor covering 66% of the first wall and up to 43% of the divertor. The operation temperature ranges which must be observed by the NIR protection cameras are, for the materials used on JET: Be 700 °C-1400 °C W coating 700 °C-1370 °C W bulk 700 °C-1400 °C. The Real-Time Protection system operates routinely since 2011 and successfully demonstrated its capability to avoid the overheating of the main chamber beryllium wall as well as of the divertor W and W-coated carbon fibre composite (CFC) tiles. During this period, less than 0.5% of the terminated discharges were aborted by a malfunction of the system. About 2%-3% of the discharges were terminated due to the detection of actual hot spots.

  18. Distributed systems for the protection of nuclear stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-01-01

    The advantages of distributed control systems usually mentioned are improved exploitation, cost reduction, and adaptation to changes in technology. These advantages are obviously very interesting for nuclear power plant applications, and many such systems have been proposed. This note comments on the application of the distributed system concept to protection systems - what should be distributed - and closes with a brief description of a protection system based on microprocessors for pressurized water stations being built in France. (auth) [fr

  19. ADDRESS SYSTEM INTEGRATION BUSINESS

    Directory of Open Access Journals (Sweden)

    Lionel Manuel Carbonell-Zamora

    2016-01-01

    Full Text Available The Integrated Strategic Direction constitutes a superior stage of Direction that expresses the coordinated system of external and internal relations with full participation in order to reach the vision of the organization. It can be insured by the use of the Strategic Direction model for the integration of the Company Direction System. This model has been applied in several companies. Recently, it was applied in the Inspection State Unit of MICONS in Santiago de Cuba through the investigation thesis for master degree developed during 18 months which objective was to validate its effectiveness in a budgeted unit, obtaining positive results when the levels of integration in the direction system increased in their external and internal relations expressed in a 37 % and 15 % respectively, which impacted the increment of the efficiency and effectiveness of all processes of the organization. 

  20. A Multi-area Model of a Physical Protection System for a Vulnerability Assessment

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Yoo, Ho Sik

    2008-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent human attacks. Among critical facilities, nuclear facilities and nuclear weapon sites require the highest level of PPS. After the September 11, 2001 terrorist attacks, international communities, including the IAEA, have made substantial efforts to protect nuclear material and nuclear facilities. These efforts include the Nuclear Security Fund established by the IAEA in 2002 and the Global Initiative to Combat Nuclear Terrorism which is launched by the USA and Russia in 2006. Without a regular assessment, the PPS might waste valuable resources on unnecessary protection or, worse yet, fail to provide adequate protection at critical points of a facility. Due to the complexity of protection systems, the assessment usually requires computer modeling techniques. Several Codes were developed to model and analyze a PPS. We also devised and implemented new analysis method and named it as Systematic Analysis of physical Protection Effectiveness (SAPE). A SAPE code consumes much time to analyze a PPS over a large area in detail. It is because SAPE uses meshes of an equal size for the analysis of a 2D map. The analysis is more accurate when the meshes of a smaller size are used. However, the analysis time is roughly proportional to the exponential of the number of meshes. Thus, the speed and accuracy is in a trade-off relation. In the paper, we suggest a multi-area model of a PPS for a vulnerability assessment to solve this problem. Using multi areas with different scales, we can accurately analyze a PPS near a target and can analyze it over a large area rather roughly

  1. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede

    2016-01-01

    the entire electrical network and changes the relay settings accordingly, but this approach is not adequate for the maritime power systems. This paper propose a decentralized adaptive protection method, where each protection relay is able to identify by itself the network status without the need of a central...... control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system......More and more maritime applications as marine vessels and offshore platforms need an adaptive protection power system. However, the adaptive protection is yet to be implemented in the maritime sector. Usually, the adaptive protection implies the existence of a central control unit that monitors...

  2. Two new discrete integrable systems

    International Nuclear Information System (INIS)

    Chen Xiao-Hong; Zhang Hong-Qing

    2013-01-01

    In this paper, we focus on the construction of new (1+1)-dimensional discrete integrable systems according to a subalgebra of loop algebra à 1 . By designing two new (1+1)-dimensional discrete spectral problems, two new discrete integrable systems are obtained, namely, a 2-field lattice hierarchy and a 3-field lattice hierarchy. When deriving the two new discrete integrable systems, we find the generalized relativistic Toda lattice hierarchy and the generalized modified Toda lattice hierarchy. Moreover, we also obtain the Hamiltonian structures of the two lattice hierarchies by means of the discrete trace identity

  3. Secure integrated circuits and systems

    CERN Document Server

    Verbauwhede, Ingrid MR

    2010-01-01

    On any advanced integrated circuit or 'system-on-chip' there is a need for security. In many applications the actual implementation has become the weakest link in security rather than the algorithms or protocols. The purpose of the book is to give the integrated circuits and systems designer an insight into the basics of security and cryptography from the implementation point of view. As a designer of integrated circuits and systems it is important to know both the state-of-the-art attacks as well as the countermeasures. Optimizing for security is different from optimizations for speed, area,

  4. Displacements of Metallic Thermal Protection System Panels During Reentry

    Science.gov (United States)

    Daryabeigi, Kamran; Blosser, Max L.; Wurster, Kathryn E.

    2006-01-01

    Bowing of metallic thermal protection systems for reentry of a previously proposed single-stage-to-orbit reusable launch vehicle was studied. The outer layer of current metallic thermal protection system concepts typically consists of a honeycomb panel made of a high temperature nickel alloy. During portions of reentry when the thermal protection system is exposed to rapidly varying heating rates, a significant temperature gradient develops across the honeycomb panel thickness, resulting in bowing of the honeycomb panel. The deformations of the honeycomb panel increase the roughness of the outer mold line of the vehicle, which could possibly result in premature boundary layer transition, resulting in significantly higher downstream heating rates. The aerothermal loads and parameters for three locations on the centerline of the windward side of this vehicle were calculated using an engineering code. The transient temperature distributions through a metallic thermal protection system were obtained using 1-D finite volume thermal analysis, and the resulting displacements of the thermal protection system were calculated. The maximum deflection of the thermal protection system throughout the reentry trajectory was 6.4 mm. The maximum ratio of deflection to boundary layer thickness was 0.032. Based on previously developed distributed roughness correlations, it was concluded that these defections will not result in tripping the hypersonic boundary layer.

  5. The role of an EU harmonised E and T system in radiation protection for public acceptance and confidence building in Romania

    International Nuclear Information System (INIS)

    Ceclan, Mihail; Ceclan, Rodica Elena; Zsombori, Vilmos; Rosca, Gabriela

    2007-01-01

    The paper aims at presenting the efforts made in the last two years for modernizing the Romanian education and training (E and T) system in Radiation Protection (RP). Increasing the responsive capacity in emergency situations is an important element for public acceptance and confidence building in Romania regarding the nuclear power. The responsive capacity in emergency situations is related to the Romanian E and T system in RP. Since January 1st, 2007 Romania became an EU member but the Romania's EU integration process will continue for still several years. The Romania's EU integration priorities are not only to transform the economy radically, but also to modernize its E and T system in general and in RP in particular. The modernization of the Romanian E and T system in RP is a real concern, related to the National Nuclear Programme (NNP) which foresees the commissioning of unit 2 of Cernavoda NPP in 2007 and the completion of units 3 and 4 until 2015. The natural way of modernizing the Romanian E and T system in RP is the cooperation with EUropean Training and Education in RP (EUTERP) Platform which was created in 2006 as a network covering the 25 European Union Member States as well as the Candidate States Bulgaria, Croatia, Romania and Turkey. Romania's integration process into EU radiation protection field is ongoing and has produced the following results: -- the Romanian branch of EUTERP Platform, called ROmanian Training and Education in Radiation Protection Platform (RO T ERP Platform) was established ; -- the RO T ERP Platform serves as a network, aiming at improving the cooperation between the various actors in the field of radiation protection E and T: - national authorities implied in RP, as CNCAN; - national bodies responsible for professional education and dedicated training, Ministry of Education and Research; - providers of training and education in the radiation protection area, universities and training centers; - professional organizations

  6. Auditory Localization Performance with Asymmetric Integrated Eye and Ear Protection

    Science.gov (United States)

    2018-03-01

    Scharine, Morgan Domanico, Ashley N Foots, Kim Fluitt, and Timothy J Mermagen Human Research and Engineering Directorate, ARL Morgan Domanico Oak...prototypes. The AIEEP is a tactical communications and protection system (TCAPS) that also provides eye protection. Participants used a laser pointer...Decibels “A-weighted” is the sound pressure level adjusted for the sensitivity of the average human ear. The reference level is the

  7. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  8. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  9. Enhancing the functionality of reactor protection systems to provide diagnostic and monitoring information: The ISATTM approach

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Rowe, B.J.; Jones, C.D.

    1996-01-01

    The ISAT TM architecture has been successfully implemented as the Single Channel Trip System (SCTS), part of the primary protection system of Nuclear Electric's Dungeness 'B' Advanced Gas-Cooled Reactors. The system is the first computer-based protection system licensed on a UK civil nuclear reactor. The system provides protection against single channel faults resulting in high coolant gas outlet temperature. The SCTS was designed to output data at several points in the system to an Ethernet to allow checks to be made on the operation of parts of the protection system and the system as a whole. In order to monitor the performance of this shutdown system a PC based monitoring system was developed to take input as data from the Ethernet, check its integrity and then analyze the data to provide information of the state of the system and subsystems. The SCTS monitor was basically intended to alert the operator to any fault on the safety system and indicate its source, provide a diagnosis of the cause of any trip initiated by the safety system, and log the occurrences of these incidents for later inspection. The intention was also to provide accurate real-time information on the thermocouple readings and to decrease the effort required to maintain the safety system. This paper will describe briefly the development of the ISAT TM monitoring system: how its requirements were arrived at, and how the design, code and testing were carried out to ensure approval for this application. It will then go on to report how the ISAT TM monitor has performed during its time in service: how more functionality has been added over and above its original requirements. Features of additional monitors for the SCTS and other ISAT TM systems will also be described. (author). 2 refs, 5 figs

  10. Outer skin protection of columbium Thermal Protection System (TPS) panels

    Science.gov (United States)

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  11. 44 CFR 65.14 - Remapping of areas for which local flood protection systems no longer provide base flood protection.

    Science.gov (United States)

    2010-10-01

    ... local flood protection systems no longer provide base flood protection. 65.14 Section 65.14 Emergency... § 65.14 Remapping of areas for which local flood protection systems no longer provide base flood... process of restoring a flood protection system that was: (i) Constructed using Federal funds; (ii...

  12. Protective relaying of power systems using mathematical morphology

    CERN Document Server

    Wu, QH; Ji, TY

    2009-01-01

    Discusses the development of novel protective relaying algorithms, using Mathematical Morphology (MM). This book introduces the fundamental principles of MM, and brings together the applications of MM to develop different protective relaying algorithms for the protection of a variety of power system components.

  13. A Hash Based Remote User Authentication and Authenticated Key Agreement Scheme for the Integrated EPR Information System.

    Science.gov (United States)

    Li, Chun-Ta; Weng, Chi-Yao; Lee, Cheng-Chi; Wang, Chun-Cheng

    2015-11-01

    To protect patient privacy and ensure authorized access to remote medical services, many remote user authentication schemes for the integrated electronic patient record (EPR) information system have been proposed in the literature. In a recent paper, Das proposed a hash based remote user authentication scheme using passwords and smart cards for the integrated EPR information system, and claimed that the proposed scheme could resist various passive and active attacks. However, in this paper, we found that Das's authentication scheme is still vulnerable to modification and user duplication attacks. Thereafter we propose a secure and efficient authentication scheme for the integrated EPR information system based on lightweight hash function and bitwise exclusive-or (XOR) operations. The security proof and performance analysis show our new scheme is well-suited to adoption in remote medical healthcare services.

  14. INTEGRATIVE AUGMENTATION OF STANDARDIZED MANAGEMENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Stanislav Karapetrovic

    2008-03-01

    Full Text Available The development, features and integrating abilities of different international standards related to management systems are discussed. A group of such standards that augment the performance of quality management systems in organizations is specifically focused on. The concept, characteristics and an illustrative example of one augmenting standard, namely ISO 10001, are addressed. Integration of standardized augmenting systems, both by themselves and within the overall management system, is examined. It is argued that, in research and practice alike, integrative augmentation represents the future of standardized quality and other management systems.

  15. Integrable deformations of Lotka-Volterra systems

    International Nuclear Information System (INIS)

    Ballesteros, Angel; Blasco, Alfonso; Musso, Fabio

    2011-01-01

    The Hamiltonian structure of a class of three-dimensional (3D) Lotka-Volterra (LV) equations is revisited from a novel point of view by showing that the quadratic Poisson structure underlying its integrability structure is just a real three-dimensional Poisson-Lie group. As a consequence, the Poisson coalgebra map Δ (2) that is given by the group multiplication provides the keystone for the explicit construction of a new family of 3N-dimensional integrable systems that, under certain constraints, contain N sets of deformed versions of the 3D LV equations. Moreover, by considering the most generic Poisson-Lie structure on this group, a new two-parametric integrable perturbation of the 3D LV system through polynomial and rational perturbation terms is explicitly found. -- Highlights: → A new Poisson-Lie approach to the integrability of Lotka-Volterra system is given. → New integrable deformations of the 3D Lotka-Volterra system are obtained. → Integrable Lotka-Volterra-type equations in 3N dimensions are deduced.

  16. Report on task I: fire protection system study

    International Nuclear Information System (INIS)

    Bernard, E.A.; Cano, G.L.

    1977-02-01

    This study (1) evaluates, on a comparative basis, the national and international regulatory and insurance standards that serve as guidance for fire protection within the nuclear power industry; (2) analyzes the recommendations contained in the major reports on the Browns Ferry Fire; (3) proposes quantitative safety goals and evaluation methods for Nuclear Power Plant Fire Protection Systems (NPPFPS); (4) identifies potential improvements that may be incorporated into NPPFPS; and (5) recommends a plan of action for continuation of the fire protections systems study

  17. Towards data protection compliance

    NARCIS (Netherlands)

    Zannone, N.; Petkovic, M.; Etalle, S.

    2010-01-01

    Privacy and data protection are fundamental issues nowadays for every organization. This paper calls for the development of methods, techniques and infrastructure to allow the deployment of privacy-aware IT systems, in which humans are integral part of the organizational processes and accountable

  18. Towards Data Protection Compliance

    NARCIS (Netherlands)

    Zannone, Nicola; Petkovic, M.; Etalle, Sandro

    2010-01-01

    Privacy and data protection are fundamental issues nowadays for every organization. This paper calls for the development of methods, techniques and infrastructure to allow the deployment of privacy-aware IT systems, in which humans are integral part of the organizational processes and accountable

  19. Integrated Safety Management System Phase 1 and 2 Verification for the Environmental Restoration Contractor Volumes 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    CARTER, R.P.

    2000-04-04

    DOE Policy 450.4 mandates that safety be integrated into all aspects of the management and operations of its facilities. The goal of an institutionalized Integrated Safety Management System (ISMS) is to have a single integrated system that includes Environment, Safety, and Health requirements in the work planning and execution processes to ensure the protection of the worker, public, environment, and the federal property over the life cycle of the Environmental Restoration (ER) Project. The purpose of this Environmental Restoration Contractor (ERC) ISMS Phase MI Verification was to determine whether ISMS programs and processes were institutionalized within the ER Project, whether these programs and processes were implemented, and whether the system had promoted the development of a safety conscious work culture.

  20. Overexpression of parkin in rat nigrostriatal dopamine system protects against methamphetamine neurotoxicity

    Science.gov (United States)

    Liu, Bin; Traini, Roberta; Killinger, Bryan; Schneider, Bernard; Moszczynska, Anna

    2013-01-01

    Methamphetamine (METH) is a central nervous system psychostimulant with a high potential for abuse. At high doses, METH causes a selective degeneration of dopaminergic terminals in the striatum, sparing other striatal terminals and cell bodies. We previously detected a deficit in parkin after binge METH in rat striatal synaptosomes. Parkin is an ubiquitin-protein E3 ligase capable of protecting dopamine neurons from diverse cellular insults. Whether the deficit in parkin mediates the toxicity of METH and whether parkin can protect from toxicity of the drug is unknown. The present study investigated whether overexpression of parkin attenuates degeneration of striatal dopaminergic terminals exposed to binge METH. Parkin overexpression in rat nigrostriatal dopamine system was achieved by microinjection of adeno-associated viral transfer vector 2/6 encoding rat parkin (AAV2/6-parkin) into the substantia nigra pars compacta. The microinjections of AAV2/6-parkin dose-dependently increased parkin levels in both the substantia nigra pars compacta and striatum. The levels of dopamine synthesizing enzyme, tyrosine hydroxylase, remained at the control levels; therefore, tyrosine hydroxylase immunoreactivity was used as an index of dopaminergic terminal integrity. In METH-exposed rats, the increase in parkin levels attenuated METH-induced decreases in striatal tyrosine hydroxylase immunoreactivity in a dose-dependent manner, indicating that parkin can protect striatal dopaminergic terminals against METH neurotoxicity. PMID:23313192

  1. Dynamic Assessment of COTS Converters-based DC Integrated Power Systems in Electric Ships

    DEFF Research Database (Denmark)

    Francés, Airán; Anvari-Moghaddam, Amjad; Diaz, Enrique Rodriguez

    2018-01-01

    , power electronics play a key role in linking the different elements of the power architecture. Moreover, the transition towards a dc distribution, which has already been established in other applications, is being regarded as a promising alternative to ease the integration of renewable sources......-level controllers, design protections or assess the compliance of the system dynamics with the standards. Experimental results are included in order to validate the proposed method....

  2. SNAP: a tool for nuclear physical protection system modeling

    International Nuclear Information System (INIS)

    Engi, D.; Grant, F.H. III.

    1979-10-01

    Nuclear safeguards systems are concerned, in part, with the physical protection of nuclear materials. The function of a physical protection system is to define the facility against adversary activities which could lead to theft of nuclear material or sabotage resulting in a radiological release. The Safeguards Network Analysis Procedure (SNAP) provides a convenient and standard analysis methodology for the evaluation of physical protection system analysis. This paper describes a detailed application of SNAP to a hypothetical nuclear facility

  3. Development of In-Core Protection System

    International Nuclear Information System (INIS)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H.

    2016-01-01

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project

  4. Development of In-Core Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H. [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project.

  5. 'H-Bahn' - Dortmund demonstration system. Automatic vehicle protection system

    Energy Technology Data Exchange (ETDEWEB)

    Rosenkranz

    1984-01-01

    The automatic vehicle protection system of the H-Bahn at the Universtiy of Dortmund is responsible for fail-safe operating of the automatic vehicles. Its functions are protection of vehicle operation and protection of passengers boarding and leaving the vehicles. These functions are managed decentrally by two fail-safe operating controllers. Besides the well-known relay-techniques of railway-fail-safe systems, electronics are applied which are based on safe operating URTL-microcontrollers. These are controlled by software stored in EPROMs. A connection link using glass-fibres serves for safe data-exchange between the two fail-safe operating controllers. The experts' favourable reports on 'train protection and safety during passenger processing' were completed in March 84; thus, transportation of passengers could start in April 84.

  6. Symplectic topology of integrable Hamiltonian systems

    International Nuclear Information System (INIS)

    Nguyen Tien Zung.

    1993-08-01

    We study the topology of integrable Hamiltonian systems, giving the main attention to the affine structure of their orbit spaces. In particular, we develop some aspects of Fomenko's theory about topological classification of integrable non-degenerate systems, and consider some relations between such systems and ''pure'' contact and symplectic geometry. We give a notion of integrable surgery and use it to obtain some interesting symplectic structures. (author). Refs, 10 figs

  7. Integrated control system for electron beam processes

    Science.gov (United States)

    Koleva, L.; Koleva, E.; Batchkova, I.; Mladenov, G.

    2018-03-01

    The ISO/IEC 62264 standard is widely used for integration of the business systems of a manufacturer with the corresponding manufacturing control systems based on hierarchical equipment models, functional data and manufacturing operations activity models. In order to achieve the integration of control systems, formal object communication models must be developed, together with manufacturing operations activity models, which coordinate the integration between different levels of control. In this article, the development of integrated control system for electron beam welding process is presented as part of a fully integrated control system of an electron beam plant, including also other additional processes: surface modification, electron beam evaporation, selective melting and electron beam diagnostics.

  8. Integrated systems innovations and applications

    CERN Document Server

    2015-01-01

    This book presents the results of discussions and presentation from the latest ISDT event (2014) which was dedicated to the 94th birthday anniversary of Prof. Lotfi A. Zade, father of Fuzzy logic. The book consists of three main chapters, namely: Chapter 1: Integrated Systems Design Chapter 2: Knowledge, Competence and Business Process Management Chapter 3: Integrated Systems Technologies Each article presents novel and scientific research results with respect to the target goal of improving our common understanding of KT integration.

  9. Systems and methods for photovoltaic string protection

    Science.gov (United States)

    Krein, Philip T.; Kim, Katherine A.; Pilawa-Podgurski, Robert C. N.

    2017-10-25

    A system and method includes a circuit for protecting a photovoltaic string. A bypass switch connects in parallel to the photovoltaic string and a hot spot protection switch connects in series with the photovoltaic string. A first control signal controls opening and closing of the bypass switch and a second control signal controls opening and closing of the hot spot protection switch. Upon detection of a hot spot condition the first control signal closes the bypass switch and after the bypass switch is closed the second control signal opens the hot spot protection switch.

  10. Improvement of the Cubic Spline Function Sets for a Synthesis of the Axial Power Distribution of a Core Protection System

    International Nuclear Information System (INIS)

    Koo, Bon-Seung; Lee, Chung-Chan; Zee, Sung-Quun

    2006-01-01

    Online digital core protection system(SCOPS) for a system-integrated modular reactor is being developed as a part of a plant protection system at KAERI. SCOPS calculates the minimum CHFR and maximum LPD based on several online measured system parameters including 3-level ex-core detector signals. In conventional ABB-CE digital power plants, cubic spline synthesis technique has been used in online calculations of the core axial power distributions using ex-core detector signals once every 1 second in CPC. In CPC, pre-determined cubic spline function sets are used depending on the characteristics of the ex-core detector responses. But this method shows an unnegligible power distribution error for the extremely skewed axial shapes by using restrictive function sets. Therefore, this paper describes the cubic spline method for the synthesis of an axial power distribution and it generates several new cubic spline function sets for the application of the core protection system, especially for the severely distorted power shapes needed reactor type

  11. Response to waste electrical and electronic equipments in China: legislation, recycling system, and advanced integrated process.

    Science.gov (United States)

    Zhou, Lei; Xu, Zhenming

    2012-05-01

    Over the past 30 years, China has been suffering from negative environmental impacts from distempered waste electrical and electronic equipments (WEEE) recycling activities. For the purpose of environmental protection and resource reusing, China made a great effort to improve WEEE recycling. This article reviews progresses of three major fields in the development of China's WEEE recycling industry: legal system, formal recycling system, and advanced integrated process. Related laws concerning electronic waste (e-waste) management and renewable resource recycling are analyzed from aspects of improvements and loopholes. The outcomes and challenges for existing formal recycling systems are also discussed. The advantage and deficiency related to advanced integrated recycling processes for typical e-wastes are evaluated respectively. Finally, in order to achieve high disposal rates of WEEE, high-quantify separation of different materials in WEEE and high added value final products produced by separated materials from WEEE, an idea of integrated WEEE recycling system is proposed to point future development of WEEE recycling industry. © 2012 American Chemical Society

  12. SEAMIST trademark in-situ instrumentation and vapor sampling system applications in the Sandia Mixed Waste Landfill Integrated Demonstration Program

    International Nuclear Information System (INIS)

    Lowry, W.E.; Dunn, S.D.; Cremer, S.C.; Williams, C.

    1994-01-01

    The SEAMIST trademark inverting membrane deployment system has been used successfully at the Mixed Waste Landfill Integrated Demonstration (MWLID) for multipoint vapor sampling/pressure measurement/permeability measurement/sensor integration demonstrations and borehole lining. Several instruments were deployed inside the SEAMIST trademark lined boreholes to detect metals, radionuclides, moisture, and geologic variations. The liner protected the instruments from contamination, maintained support of the uncased borehole wall, and sealed the total borehole from air circulation. The current activities have included the installation of three multipoint vapor sampling systems and sensor integration systems in 100-foot-deep vertical boreholes. A long term pressure monitoring program has recorded barometric pressure effects at depth with relatively high spatial resolution. The SEAMIST trademark system has been integrated with a variety of hydrologic and chemical sensors for in-situ measurements, demonstrating its versatility as an instrument deployment system which allows easy emplacement and removal. Standard SEAMIST trademark vapor sampling systems were also integrated with state-of-the-art VOC analysis technologies (automated GC, UV laser fluorometer). The results and status of these demonstration tests are presented

  13. Architecture and Fault Identification of Wide-area Protection System

    Directory of Open Access Journals (Sweden)

    Yuxue Wang

    2012-09-01

    Full Text Available Wide-area protection system (WAPS is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structurecentralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional distance protection algorithm was taken as an example to illustrate the functions of the constituent units. Faulted components can be detected based on multi-source imformation fuse in the algorithm. And the algorithm cannot only improve the selectivity, the rapidity, and the reliability of relaying protection but also has high fault tolerant capability. A simulation of 220 kV grid systems in Easter Hubei province shows the effectiveness of the wide-area protection system presented by this paper.

  14. Integrated Reporting Information System -

    Data.gov (United States)

    Department of Transportation — The Integrated Reporting Information System (IRIS) is a flexible and scalable web-based system that supports post operational analysis and evaluation of the National...

  15. A critical review of the system of radiation protection

    International Nuclear Information System (INIS)

    2000-01-01

    Our modern, information society is increasingly interested in transparency and participation in many aspects of government, and this is particularly true in areas involving public health and environmental protection. Radiation protection is no exception to this trend. Scientific rationale that was once sufficient to explain radiation protection theory and practice is no longer adequate. The need to address and communicate theory, practice and the decision-making process to a wider audience has given rise to numerous debates and led the radiation protection community to revisit the framework of the system of radiation protection. The very fundamentals of the system of radiation protection continue to be questioned in a healthy fashion, and many aspects have been identified which could better serve stakeholders given some additional thought in the light of modern societal needs. This report is the summary of the NEA's first reflections in this area, and describes those aspects of the current international system of radiation protection that could be improved. Suggested directions for improvement are provided. (author)

  16. Dependability Evaluation of Advanced Diverse Protection System

    International Nuclear Information System (INIS)

    Oh, Yang Gyun; Lee, Yoon Hee; Sohn, Se Do; Baek, Seung Min; Lee, Sang Jeong

    2014-01-01

    For the mitigation of anticipated transients without scram (ATWS) as well as common cause failure (CCF) within the plant protection system (PPS) and the emergency safety feature . component control system (ESF-CCS), the diverse protection system (DPS) has been designed by KEPCO Engineering and Construction Company. Recently KEPCO E and C has developed the advanced diverse protection system (ADPS), which has four redundant channels, in an attempt to enhance a fault-tolerant capability of the system. For the evaluation of overall system improvement effects of the ADPS compared with the DPS, the dependability evaluation results are described herein. For all dependability attributes, this paper suggests a practical dependability evaluation method which uses quantitative dependability scores and indices. An overall dependability evaluation index (DEI) for the ADPS is evaluated with the average value of reliability/ security/maintainability/safety indices (i.e., RID, SID, MID, and SID') for dependability. The evaluation results show that the DEI value of ADPS can be improved by approximately 23% compared with that of the DPS, thanks to its fault-tolerant system architecture, software design changes, and external interface design features. Several suggestions have been made, in this paper, of an overall quantitative dependability evaluation method for the nuclear instrumentation and control (I and C) systems including the DPS and ADPS, and the usefulness of dependability evaluation on nuclear I and C systems has been confirmed

  17. Intelligent Integrated System Health Management

    Science.gov (United States)

    Figueroa, Fernando

    2012-01-01

    Intelligent Integrated System Health Management (ISHM) is the management of data, information, and knowledge (DIaK) with the purposeful objective of determining the health of a system (Management: storage, distribution, sharing, maintenance, processing, reasoning, and presentation). Presentation discusses: (1) ISHM Capability Development. (1a) ISHM Knowledge Model. (1b) Standards for ISHM Implementation. (1c) ISHM Domain Models (ISHM-DM's). (1d) Intelligent Sensors and Components. (2) ISHM in Systems Design, Engineering, and Integration. (3) Intelligent Control for ISHM-Enabled Systems

  18. Distributed Power-Generation Systems and Protection

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng; Yang, Dongsheng

    2017-01-01

    the challenging issues and, more importantly, to leverage the energy generation, stringent demands from both utility operators and consumers have been imposed on the DPGS. Furthermore, as the core of energy conversion, numerous power electronic converters employing advanced control techniques have been developed...... for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS...

  19. The protection of photovoltaic power systems from lightning

    Science.gov (United States)

    Rogers, C. B.

    Lightning protection techniques at nine prototype photovoltaic power system sites with outputs from 18-225 kW are described. Noting that protection schemes are devised to fit isokeraunic data for specific sites, grounding is cited as a common feature for all systems. The grounds are, in separate instances, connected to junction boxes, frames of the solar cell panels, lead from the dc center, from the dc negative terminal, from the frames and equipment, at the array turntable, or from the building rebar frames. The dc power cables are protected by either metal conduit, metal conduit ground wire, direct burial, by rigid metal conduit, ground conductors, or by ground conductors at the ends of the conduit run. Costs run from 0.01-0.28$/W, with all the systems outfitted with bypass and blocking diodes. Direct stroke protection is viewed as less important than isokeraunic data.

  20. Integration of a hydraulic production plant in a weak power system on a long radial line

    Energy Technology Data Exchange (ETDEWEB)

    Lariviere, P. [Hydro-Quebec TransEnergie, 5655 de Marseille, Montreal, Quebec (Canada); Racine, M. [Hydro-Quebec TransEnergie, C.P. 10 000, Montreal, Quebec (Canada)

    2009-03-15

    Integrating power plants on long lines and weak power systems requires some care. To this effect, a study was conducted to determine if severe disturbances could result when a hydraulic production plant is integrated along a very long radial transmission line. Frequency responses were evaluated to identify possible resonant system operating conditions. Many events such as faults, transformer energyzing and line opening were investigated. All power plant synchronous machines were represented including exciter and governor regulators. Impact of dynamic modeling of the load was examined. The study demonstrates that the overall protective strategy implemented will limit worst overvoltage constraints imposed to equipment and load within an acceptable level. (author)

  1. Fully integrated safeguards and security for reprocessing plant monitoring

    International Nuclear Information System (INIS)

    Duran, Felicia Angelica; Ward, Rebecca; Cipiti, Benjamin B.; Middleton, Bobby D.

    2011-01-01

    Nuclear fuel reprocessing plants contain a wealth of plant monitoring data including material measurements, process monitoring, administrative procedures, and physical protection elements. Future facilities are moving in the direction of highly-integrated plant monitoring systems that make efficient use of the plant data to improve monitoring and reduce costs. The Separations and Safeguards Performance Model (SSPM) is an analysis tool that is used for modeling advanced monitoring systems and to determine system response under diversion scenarios. This report both describes the architecture for such a future monitoring system and present results under various diversion scenarios. Improvements made in the past year include the development of statistical tests for detecting material loss, the integration of material balance alarms to improve physical protection, and the integration of administrative procedures. The SSPM has been used to demonstrate how advanced instrumentation (as developed in the Material Protection, Accounting, and Control Technologies campaign) can benefit the overall safeguards system as well as how all instrumentation is tied into the physical protection system. This concept has the potential to greatly improve the probability of detection for both abrupt and protracted diversion of nuclear material.

  2. Climate warming, marine protected areas and the ocean-scale integrity of coral reef ecosystems.

    Directory of Open Access Journals (Sweden)

    Nicholas A J Graham

    Full Text Available Coral reefs have emerged as one of the ecosystems most vulnerable to climate variation and change. While the contribution of a warming climate to the loss of live coral cover has been well documented across large spatial and temporal scales, the associated effects on fish have not. Here, we respond to recent and repeated calls to assess the importance of local management in conserving coral reefs in the context of global climate change. Such information is important, as coral reef fish assemblages are the most species dense vertebrate communities on earth, contributing critical ecosystem functions and providing crucial ecosystem services to human societies in tropical countries. Our assessment of the impacts of the 1998 mass bleaching event on coral cover, reef structural complexity, and reef associated fishes spans 7 countries, 66 sites and 26 degrees of latitude in the Indian Ocean. Using Bayesian meta-analysis we show that changes in the size structure, diversity and trophic composition of the reef fish community have followed coral declines. Although the ocean scale integrity of these coral reef ecosystems has been lost, it is positive to see the effects are spatially variable at multiple scales, with impacts and vulnerability affected by geography but not management regime. Existing no-take marine protected areas still support high biomass of fish, however they had no positive affect on the ecosystem response to large-scale disturbance. This suggests a need for future conservation and management efforts to identify and protect regional refugia, which should be integrated into existing management frameworks and combined with policies to improve system-wide resilience to climate variation and change.

  3. Climate warming, marine protected areas and the ocean-scale integrity of coral reef ecosystems.

    Science.gov (United States)

    Graham, Nicholas A J; McClanahan, Tim R; MacNeil, M Aaron; Wilson, Shaun K; Polunin, Nicholas V C; Jennings, Simon; Chabanet, Pascale; Clark, Susan; Spalding, Mark D; Letourneur, Yves; Bigot, Lionel; Galzin, René; Ohman, Marcus C; Garpe, Kajsa C; Edwards, Alasdair J; Sheppard, Charles R C

    2008-08-27

    Coral reefs have emerged as one of the ecosystems most vulnerable to climate variation and change. While the contribution of a warming climate to the loss of live coral cover has been well documented across large spatial and temporal scales, the associated effects on fish have not. Here, we respond to recent and repeated calls to assess the importance of local management in conserving coral reefs in the context of global climate change. Such information is important, as coral reef fish assemblages are the most species dense vertebrate communities on earth, contributing critical ecosystem functions and providing crucial ecosystem services to human societies in tropical countries. Our assessment of the impacts of the 1998 mass bleaching event on coral cover, reef structural complexity, and reef associated fishes spans 7 countries, 66 sites and 26 degrees of latitude in the Indian Ocean. Using Bayesian meta-analysis we show that changes in the size structure, diversity and trophic composition of the reef fish community have followed coral declines. Although the ocean scale integrity of these coral reef ecosystems has been lost, it is positive to see the effects are spatially variable at multiple scales, with impacts and vulnerability affected by geography but not management regime. Existing no-take marine protected areas still support high biomass of fish, however they had no positive affect on the ecosystem response to large-scale disturbance. This suggests a need for future conservation and management efforts to identify and protect regional refugia, which should be integrated into existing management frameworks and combined with policies to improve system-wide resilience to climate variation and change.

  4. The implementation and evaluation of physical protection system of the IEA-R1 reactor

    International Nuclear Information System (INIS)

    Vaz, Antonio Carlos Alves

    2016-01-01

    The September 11, 2001 terrorist attacks in New York, the accident at the Fukushima nuclear power plant on March 2011 and the recent attacks in Paris on November 2015 are examples of events that justify the efforts of the International Agency of Energy Atomic - IAEA to improve security at nuclear facility. The Brazilian government has been collaborating with this project and investing resources to improve the Physical Protection System - PPS of the nuclear research reactor system, technically is associated with the elements of detection, delay and response. The PPS is an integrated system of people, equipment and procedures used to protect nuclear facilities and radioactive sources against threat, theft or sabotage. The PPS works to avoid, to mitigate or to minimize the consequences caused by these actions. This study evaluates the PPS of the reactor, identifying the vulnerabilities and suggesting ways to improve the system effectiveness. The analyses were based on the methodology developed by Sandia National Laboratories´ security experts in Albuquerque - USA, allowing the system evaluation through hypothetical and probabilistic analyzes; identifying threats, determining the targets and analyzing the possible adversaries paths. From the methodology adopted was obtained the value around 40% for PE indicator, which shows the need to improve the system to minimizing the vulnerabilities. (author)

  5. Data Entities and Information System Matrix for Integrated Agriculture Information System (IAIS)

    Science.gov (United States)

    Budi Santoso, Halim; Delima, Rosa

    2018-03-01

    Integrated Agriculture Information System is a system that is developed to process data, information, and knowledge in Agriculture sector. Integrated Agriculture Information System brings valuable information for farmers: (1) Fertilizer price; (2) Agriculture technique and practise; (3) Pest management; (4) Cultivation; (5) Irrigation; (6) Post harvest processing; (7) Innovation in agriculture processing. Integrated Agriculture Information System contains 9 subsystems. To bring an integrated information to the user and stakeholder, it needs an integrated database approach. Thus, researchers describes data entity and its matrix relate to subsystem in Integrated Agriculture Information System (IAIS). As a result, there are 47 data entities as entities in single and integrated database.

  6. Integrated Project Management System description

    International Nuclear Information System (INIS)

    1987-03-01

    The Uranium Mill Tailings Remedial Action (UMTRA) Project is a Department of Energy (DOE) designated Major System Acquisition (MSA). To execute and manage the Project mission successfully and to comply with the MSA requirements, the UMTRA Project Office (''Project Office'') has implemented and operates an Integrated Project Management System (IPMS). The Project Office is assisted by the Technical Assistance Contractor's (TAC) Project Integration and Control (PIC) Group in system operation. Each participant, in turn, provides critical input to system operation and reporting requirements. The IPMS provides a uniform structured approach for integrating the work of Project participants. It serves as a tool for planning and control, workload management, performance measurement, and specialized reporting within a standardized format. This system description presents the guidance for its operation. Appendices 1 and 2 contain definitions of commonly used terms and abbreviations and acronyms, respectively. 17 figs., 5 tabs

  7. CHALLENGES AND OPPORTUNITIES--INTEGRATED LIFE-CYCLE OPTIMIZATION INITIATIVES FOR THE HANFORD RIVER PROTECTION PROJECT--WASTE TREATMENT PLANT

    International Nuclear Information System (INIS)

    Auclair, K. D.

    2002-01-01

    of issues across contract boundaries is a more difficult matter. This aspect, one of a seamless systems approach to the treatment of tank wastes at the Hanford site, is the focus of the Optimization Studies. This ''big O''Optimization of Life-Cycle operations is what is meant when the term ''optimization'' is used on the River Protection Project and initiatives cited in this paper. From the early contractor centric methods and processes used to move toward an integrated solution, through extensive partnering approaches, to the current quality initiatives with multi-organizational participation, significant progress is being made towards achieving the goal of truly integrated life-cycle optimization for the Department of Energy's River Protection Project and Waste Treatment Plant

  8. 78 FR 30870 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2013-05-23

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: National Marine Protected...) invited federal, state, commonwealth, and territorial marine protected area (MPA) programs with... of Marine Protected Areas of the United States (Framework), developed in response to Executive Order...

  9. Conceptual integrated approach for the magnet system of a tokamak reactor

    International Nuclear Information System (INIS)

    Duchateau, J.-L.; Hertout, P.; Saoutic, B.; Artaud, J.-F.; Zani, L.; Reux, C.

    2014-01-01

    Highlights: • We give a conceptual approach of a fusion reactor magnet system based on analytical formula. • We give design criteria for the CS and TF cable in conduit conductors and for the magnet system structural description. • We apply this conceptual approach to ITER and we crosscheck with actual characteristics. • We apply this conceptual approach to a possible version of DEMO. - Abstract: In the framework of the reflexion about DEMO, a conceptual integrated approach for the magnet system of a tokamak reactor is presented. This objective is reached using analytical formulas which are presented in this paper, coupled to a Fortran code ESCORT (Electromagnetic Superconducting System for the Computation of Research Tokamaks), to be integrated into SYCOMORE, a code for reactor modelling presently in development at CEA/IRFM in Cadarache, using the tools of the EFDA Integrated Tokamak Modelling task force. The analytical formulas deal with all aspects of the magnet system, starting from the derivation of the TF system general geometry, from the plasma main characteristics. The design criteria for the cable current density and the structural design of the toroidal field and central solenoid systems are presented, enabling to deliver the radial thicknesses of the magnets and enabling also to estimate the plasma duration of the plateau. As a matter of fact, a pulsed version DEMO is presently actively considered in the European programmes. Considerations regarding the cryogenics and the protection are given, affecting the general design. An application of the conceptual approach is presented, allowing a comparison between ESCORT output data and actual ITER parameters and giving the main characteristics of a possible version for DEMO

  10. Integrated modelling of ecosystem services and energy systems research

    Science.gov (United States)

    Agarwala, Matthew; Lovett, Andrew; Bateman, Ian; Day, Brett; Agnolucci, Paolo; Ziv, Guy

    2016-04-01

    The UK Government is formally committed to reducing carbon emissions and protecting and improving natural capital and the environment. However, actually delivering on these objectives requires an integrated approach to addressing two parallel challenges: de-carbonising future energy system pathways; and safeguarding natural capital to ensure the continued flow of ecosystem services. Although both emphasise benefiting from natural resources, efforts to connect natural capital and energy systems research have been limited, meaning opportunities to improve management of natural resources and meet society's energy needs could be missed. The ecosystem services paradigm provides a consistent conceptual framework that applies in multiple disciplines across the natural and economic sciences, and facilitates collaboration between them. At the forefront of the field, integrated ecosystem service - economy models have guided public- and private-sector decision making at all levels. Models vary in sophistication from simple spreadsheet tools to complex software packages integrating biophysical, GIS and economic models and draw upon many fields, including ecology, hydrology, geography, systems theory, economics and the social sciences. They also differ in their ability to value changes in natural capital and ecosystem services at various spatial and temporal scales. Despite these differences, current models share a common feature: their treatment of energy systems is superficial at best. In contrast, energy systems research has no widely adopted, unifying conceptual framework that organises thinking about key system components and interactions. Instead, the literature is organised around modelling approaches, including life cycle analyses, econometric investigations, linear programming and computable general equilibrium models. However, some consistencies do emerge. First, often contain a linear set of steps, from exploration to resource supply, fuel processing, conversion

  11. System architecture for microprocessor based protection system

    International Nuclear Information System (INIS)

    Gallagher, J.M. Jr.; Lilly, G.M.

    1976-01-01

    This paper discusses the architectural design features to be employed by Westinghouse in the application of distributed digital processing techniques to the protection system. While the title of the paper makes specific reference to microprocessors, this is only one (and the newest) of the building blocks which constitutes a distributed digital processing system. The actual system structure (as realized through utilization of the various building blocks) is established through considerations of reliability, licensability, and cost. It is the intent of the paper to address these considerations licenstions as they relate to the architectural design features. (orig.) [de

  12. Application Software for the Cabinet Operator Module of the Reactor Protection System

    International Nuclear Information System (INIS)

    Lee, Hyun-Chul; Jung, Hae-Won; Lee, Sung-Jin; Koo, Young-Ho; Kim, Seong-Tae; Kwak, Tae-Kil; Jin, Kyo-Hong

    2006-01-01

    A reactor protection system (RPS) plays the roles of generating the reactor trip signal and the engineered safety features (ESF) actuation signal when the monitored plant processes reach predefined limits. A Korean project group, so-called KNICS (Korean Nuclear I and C System), is developing a new digitalized RPS and the Cabinet Operator Module (COM) of the RPS which is used for the RPS integrity testing and monitoring by equipment operators. A flat panel display (FPD) with a touch screen capability is provided as a main user interface for the RPS. This paper shows the application software developed for the COM FPD. Equipment operators can monitor the status of the RPS and carry out various tests to verify system functions by means of the application software. A qualified hardware and software development environment are used to develop the application software

  13. Nuclear plants gain integrated information systems

    International Nuclear Information System (INIS)

    Villavicencio-Ramirez, A.; Rodriquez-Alvarez, J.M.

    1994-01-01

    With the objective of simplifying the complex mesh of computing devices employed within nuclear power plants, modern technology and integration techniques are being used to form centralized (but backed up) databases and distributed processing and display networks. Benefits are immediate as a result of the integration and the use of standards. The use of a unique data acquisition and database subsystem optimizes the high costs of engineering, as this task is done only once for the life span of the system. This also contributes towards a uniform user interface and allows for graceful expansion and maintenance. This article features an integrated information system, Sistema Integral de Informacion de Proceso (SIIP). The development of this system enabled the Laguna Verde Nuclear Power plant to fully use the already existing universe of signals and its related engineering during all plant conditions, namely, start up, normal operation, transient analysis, and emergency operation. Integrated systems offer many advantages over segregated systems, and this experience should benefit similar development efforts in other electric power utilities, not only for nuclear but also for other types of generating plants

  14. Smart power systems and renewable energy system integration

    CERN Document Server

    2016-01-01

    This monograph presents a wider spectrum of researches, developments, and case specific studies in the area of smart power systems and integration of renewable energy systems. The book will be for the benefit of a wider audience including researchers, postgraduate students, practicing engineers, academics, and regulatory policy makers. It covers a wide range of topics from fundamentals, and modelling and simulation aspects of traditional and smart power systems to grid integration of renewables; Micro Grids; challenges in planning and operation of a smart power system; risks, security, and stability in smart operation of a power system; and applied research in energy storage. .

  15. Ukraine-Japanese-Swedish project: Upgrading of perimeter protection system at Kharkov Institute of Physics and Technology (KIPT)

    International Nuclear Information System (INIS)

    Mikahaylov, V.; Lapshin, V.; Ek, P.; Flyghed, L.; Nilsson, A.; Ooka, N.; Shimizu, K.; Tanuma, K.

    2001-01-01

    project a lot of equipment manufactured in Sweden, Japan, and partly in the USA, was procured by funding by Japan and delivered to KIPT. Completion of the work was scheduled to take place in about one year. However, despite the selfless work of the KIPT personnel and other exports, the upgrading of the perimeter initiated in October 1998 was completed, due to difficult weather conditions, custom problems etc., at the end of 2000. The project included installation of more than 6 kilometers of the standard external fencing along the perimeter of protected area of the nuclear facility, microwave and other for intrusion detection, system for cable TV alarm assessment and control (CCTV), diesel-generation to serve as an emergency power supply source for the entire physical protection system. The center alarm station (CAS) integrated the control equipment for the perimeter protection system provided by the Sweden and Japan as well as for the storage delivered by the USA. The CAS was tested and came into operation as an integral part of the entire physical protection system at KIPT in December 2000. The successful completion of the project has lead to a significant improvement of the protection level at KIPT. Thereby it has significantly reduced the possibility for unauthorised withdrawal of the special fissionable material that is available at KIPT in quantities and forms attractive for nuclear terrorists and saboteurs. The commissioning of a new modem physical protection system specially designed for KIPT point at some future problems, in particular, as regards training of operation and engineering personnel, providing service and maintenance, and providing necessary spare parts. The Japan Technical Secretariat and the Swedish Nuclear Power Inspectorate have undertaken to provide necessary support for service and maintenance, including spare parts, until the end of 2002. However, for a longer period of time the KIPT management needs to focus on this issue. (author)

  16. NASA UAS Integration into the NAS Project: Human Systems Integration

    Science.gov (United States)

    Shively, Jay

    2016-01-01

    This presentation provides an overview of the work the Human Systems Integration (HSI) sub-project has done on detect and avoid (DAA) displays while working on the UAS (Unmanned Aircraft System) Integration into the NAS project. The most recent simulation on DAA interoperability with Traffic Collision Avoidance System (TCAS) is discussed in the most detail. The relationship of the work to the larger UAS community and next steps are also detailed.

  17. Passive fire building protection system evaluation (case study: millennium ict centre)

    Science.gov (United States)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  18. Permanent cathodic protection monitoring systems for offshore pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Britton, Jim [Deepwater Corrosion Services Inc., Houston, TX (United States)

    2009-07-01

    Historically offshore pipeline cathodic protection monitoring has relied on the use of portable survey techniques. This has typically relied on ROV assisted or surface deployed survey methods. These methods have been shown to have technical as well as economic shortcomings, this is particularly true of buried offshore pipelines where accuracy is always questionable. As more focus is being placed on offshore pipeline integrity, it was time for a new method to emerge. The technology discussed involves the retro-placement of permanent clamp-on monitors onto the pipeline which can measure pipeline to seawater potential as well as current density. The sensors can be interrogated locally using light powered subsea voltage readouts. Application of the technology can be either during pipeline construction, during installation of life extension CP systems, or during routine subsea pipeline interventions. The new method eliminates the need for long cables or expensive acoustic or modulated data transfer and provides all the information required to fully verify CP system performance, thus eliminating the need for expensive close-interval surveys. Some deployment case histories will be presented along with feasibility of application on deep water pipelines and comparative economics. (author)

  19. Common Systems Integration Lab (CSIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Common Systems Integration Lab (CSIL)supports the PMA-209 Air Combat Electronics Program Office. CSIL also supports development, test, integration and life cycle...

  20. Integrated Systems Health Management for Intelligent Systems

    Science.gov (United States)

    Figueroa, Fernando; Melcher, Kevin

    2011-01-01

    The implementation of an integrated system health management (ISHM) capability is fundamentally linked to the management of data, information, and knowledge (DIaK) with the purposeful objective of determining the health of a system. It is akin to having a team of experts who are all individually and collectively observing and analyzing a complex system, and communicating effectively with each other in order to arrive at an accurate and reliable assessment of its health. In this paper, concepts, procedures, and approaches are presented as a foundation for implementing an intelligent systems ]relevant ISHM capability. The capability stresses integration of DIaK from all elements of a system. Both ground-based (remote) and on-board ISHM capabilities are compared and contrasted. The information presented is the result of many years of research, development, and maturation of technologies, and of prototype implementations in operational systems.

  1. A 2+1 non-isospectral discrete integrable system and its discrete integrable coupling system

    International Nuclear Information System (INIS)

    Yu Fajun; Zhang Hongqing

    2006-01-01

    In this Letter by considering a (2+1)-dimensional discrete non-isospectral linear problem, a new (2+1)-dimensional integrable lattice hierarchy is constructed. It shows that generalization of the Blaszak-Marciniak lattice hierarchy can be obtained as a reduction. Then an extended algebraic system X-bar of X is presented, from which the integrable coupling system of the (2+1)-dimensional discrete non-isospectral Blaszak-Marciniak lattice equations are obtained

  2. Beam loss monitor system for machine protection

    CERN Document Server

    Dehning, B

    2005-01-01

    Most beam loss monitoring systems are based on the detection of secondary shower particles which depose their energy in the accelerator equipment and finally also in the monitoring detector. To allow an efficient protection of the equipment, the likely loss locations have to be identified by tracking simulations or by using low intensity beams. If superconducting magnets are used for the beam guiding system, not only a damage protection is required but also quench preventions. The quench levels for high field magnets are several orders of magnitude below the damage levels. To keep the operational efficiency high under such circumstances, the calibration factor between the energy deposition in the coils and the energy deposition in the detectors has to be accurately known. To allow a reliable damage protection and quench prevention, the mean time between failures should be high. If in such failsafe system the number of monitors is numerous, the false dump probability has to be kept low to keep a high operation...

  3. Airspace Systems Program: Next Generation Air Transportation System, NextGen Systems Analysis, Integration and Evaluation Project. Version 1.0; Project Plan

    Science.gov (United States)

    Quon, Leighton

    2010-01-01

    The key objectives of the NASA ASP are to: Improve mobility, capacity efficiency and access of the airspace system. Improve collaboration, predictability, and flexibility for the airspace users. Enable accurate modeling and simulation of air transportation systems. Accommodate operations of all classes of aircraft. Maintain system safety and environmental protection. In support of these program objectives, the major goal of the NextGen-SAIE Project is to enable the transition of key capacity and efficiency improvements to the NAS. Since many aspects of the NAS are unique to specific airport or airspace environments, demand on various parts of the NAS is not expected to increase equally as system demand grows. SAIE will provide systems level analysis of the NAS characteristics, constraints, and demands such that a suite of capacity-increasing concepts and technologies for system solutions are enabled and facilitated. The technical objectives in support of this goal are the following: Integration, evaluation, and transition of more mature concepts and technologies in an environment that faithfully emulates real-world complexities. Interoperability research and analysis of ASP technologies across ATM functions is performed to facilitate integration and take ASP concepts and technologies to higher Technology Readiness Level (TRL). Analyses are conducted on the program s concepts to identify the system benefits or impacts. System level analysis is conducted to increase understanding of the characteristics and constraints of airspace system and its domains.

  4. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  5. Assessment of physical protection systems: EVA method

    International Nuclear Information System (INIS)

    Bernard, J.-L.; Lamotte, C.; Jorda, A.

    2001-01-01

    CEA's missions in various sectors of activity such as nuclear, defence, industrial contracts and the associated regulatory requirements, make it necessary to develop a strategy in the field of physical protection. In particular, firms having nuclear materials are subject to the July 25, 1980 law no.80-572 on the protection and control of nuclear materials. A holding permit delivered by the regulatory authority is conditioned to the protection by the operator of the nuclear materials used. In France it is the nuclear operator who must demonstrate, in the form of a security study, that potential aggressors would be neutralised before they could escape with the material. To meet these requirements, we have developed methods to assess the vulnerability of our facilities. The EVA method, the French acronym for 'Evaluation de la vulnerabilite des Acces' (access vulnerability system) allows dealing with internal and external threats involving brutal actions. In scenarios relating to external threat, the intruders get past the various barriers of our protection system, attempting to steal a large volume of material in one swoop and then escape. In the case of internal threat, the goal is the same. However, as the intruder usually has access to the material in the scope of his activities, the action begins at the level of the target. Our protection system is based on in-depth defense where the intruders are detected and then delayed in their advance towards their target to allow time for intervention forces to intercept them

  6. DKIST facility management system integration

    Science.gov (United States)

    White, Charles R.; Phelps, LeEllen

    2016-07-01

    The Daniel K. Inouye Solar Telescope (DKIST) Observatory is under construction at Haleakalā, Maui, Hawai'i. When complete, the DKIST will be the largest solar telescope in the world. The Facility Management System (FMS) is a subsystem of the high-level Facility Control System (FCS) and directly controls the Facility Thermal System (FTS). The FMS receives operational mode information from the FCS while making process data available to the FCS and includes hardware and software to integrate and control all aspects of the FTS including the Carousel Cooling System, the Telescope Chamber Environmental Control Systems, and the Temperature Monitoring System. In addition it will integrate the Power Energy Management System and several service systems such as heating, ventilation, and air conditioning (HVAC), the Domestic Water Distribution System, and the Vacuum System. All of these subsystems must operate in coordination to provide the best possible observing conditions and overall building management. Further, the FMS must actively react to varying weather conditions and observational requirements. The physical impact of the facility must not interfere with neighboring installations while operating in a very environmentally and culturally sensitive area. The FMS system will be comprised of five Programmable Automation Controllers (PACs). We present a pre-build overview of the functional plan to integrate all of the FMS subsystems.

  7. Explicit integration of some integrable systems of classical mechanics

    OpenAIRE

    Basak Gancheva, Inna

    2011-01-01

    The main objective of the thesis is the analytical and geometrical study of several integrable finite-dimentional dynamical systems of classical mechanics, which are closely related, namely: - the classical generalization of the Euler top: the Zhukovski-Volterra (ZV) system describing the free motion of a gyrostat, i.e., a rigid body carrying a symmetric rotator whose axis is fixed in the body; - the Steklov-Lyapunov integrable case of the Kirchhoff equations describing the motio...

  8. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  9. Heat Exchange in “Human body - Thermal protection - Environment” System

    Science.gov (United States)

    Khromova, I. V.

    2017-11-01

    This article is devoted to the issues of simulation and calculation of thermal processes in the system called “Human body - Thermal protection - Environment” under low temperature conditions. It considers internal heat sources and convective heat transfer between calculated elements. Overall this is important for the Heat Transfer Theory. The article introduces complex heat transfer calculation method and local thermophysical parameters calculation method in the system called «Human body - Thermal protection - Environment», considering passive and active thermal protections, thermophysical and geometric properties of calculated elements in a wide range of environmental parameters (water, air). It also includes research on the influence that thermal resistance of modern materials, used in special protective clothes development, has on heat transfer in the system “Human body - Thermal protection - Environment”. Analysis of the obtained results allows adding of the computer research data to experiments and optimizing of individual life-support system elements, which are intended to protect human body from exposure to external factors.

  10. A Fall Protection System for High-Rise Construction

    Directory of Open Access Journals (Sweden)

    Haluk Çeçen

    2013-01-01

    Full Text Available In construction industry, the number of fatal and nonfatal occupational injuries is higher than other industries. Among causes of these accidents, “falls” play a key role. This situation reveals the importance for carrying out research in fall protection systems. In this paper, a practical, economical, and functional fall protection system is introduced. Following determination and evaluation of existing solutions, weekly brainstorming meetings were held among the responsible project staff (general coordinator, project coordinator, project manager, site manager, and health and safety manager. As a result of these meetings, design criteria were developed. Based on these criteria, the fall protection system for high-rise construction (FPSFHC was developed which satisfied all the specified design criteria. Required materials were procured from local dealers. In this paper, criteria used in design and details of the final design are presented. Field performance of the system is evaluated, and recommendations for further development and standardization of the system are added.

  11. Architecture of portable electronic medical records system integrated with streaming media.

    Science.gov (United States)

    Chen, Wei; Shih, Chien-Chou

    2012-02-01

    Due to increasing occurrence of accidents and illness during business trips, travel, or overseas studies, the requirement for portable EMR (Electronic Medical Records) has increased. This study proposes integrating streaming media technology into the EMR system to facilitate referrals, contracted laboratories, and disease notification among hospitals. The current study encoded static and dynamic medical images of patients into a streaming video format and stored them in a Flash Media Server (FMS). Based on the Taiwan Electronic Medical Record Template (TMT) standard, EMR records can be converted into XML documents and used to integrate description fields with embedded streaming videos. This investigation implemented a web-based portable EMR interchanging system using streaming media techniques to expedite exchanging medical image information among hospitals. The proposed architecture of the portable EMR retrieval system not only provides local hospital users the ability to acquire EMR text files from a previous hospital, but also helps access static and dynamic medical images as reference for clinical diagnosis and treatment. The proposed method protects property rights of medical images through information security mechanisms of the Medical Record Interchange Service Center and Health Certificate Authorization to facilitate proper, efficient, and continuous treatment of patients.

  12. Design of the interlock and protection system for the SPIDER experiment

    International Nuclear Information System (INIS)

    Pomaro, N.; Grando, L.; Luchetta, A.; Paolucci, F.; Sartori, F.

    2013-01-01

    Highlights: •A custom designed interlock and protection system for SPIDER experiment is described. •It includes two subsystems implementing slow and fast protection functions. •High reliability PLCs are adopted for slow protection. •Fiber-optic based, custom designed fast logic circuitry is proposed for fast protection. •Accelerators breakdown events are also managed by the fast subsystem. -- Abstract: Unprecedented levels of beam energy and power are required for ITER Neutral Beam Heating systems. SPIDER experiment is an experimental device aimed to test and optimize a full size beam source satisfying ITER requirements. SPIDER experiment operation involves high power, voltage, temperature, and gas pressure. All these critical conditions are present simultaneously, so that any failure if not properly detected and managed is likely to cause severe damage. The Interlock and Protection System is a high-reliability system devoted to the investment protection of SPIDER. Its main purpose is to manage abnormal events occurring in one or more plants in order to minimize adverse consequences. The Interlock System also manages the SPIDER Operating Modes, defining the set and status of the Plants used in the various possible experimental configurations. In addition, the Interlock and Protection System takes care of particular events occurring during normal SPIDER operation, i.e. electrical arcs between accelerator grids, named breakdowns. Their treatment is committed to the Interlock and Protection System, as they need to be managed timely and with absolute reliability like actual faults. To perform the required functions, the Interlock and Protection System is interfaced with most SPIDER plants and with the SPIDER Control and Data Acquisition System. The paper describes the rationale of the protection functions, their implementation in the design and the technical specifications of the system

  13. Sub-assembly accident protection instrumentation systems

    International Nuclear Information System (INIS)

    Vaughan, G.J.; Lunt, A.R.W.; Evans, N.J.; Lawrence, L.A.J.

    1982-01-01

    The possibility of an incident in a sub-assembly progressing to the stage at which the whole core may be at hazard has to be guarded against. It is proposed that for CDFR specific instrumentation will be provided to protect against this incident. Three such systems are described, these are: Acoustic Boiling Noise Detection, Burst Pin Detection and Individual Sub-Assembly Thermocouple (ISAT) monitoring. In the ISAT case, multiplexers and microprocessors are employed, using novel techniques to ensure failure-to-safety. The role of these systems and the implementation of them in the reactor design are also considered. It is concluded that sufficient protection can be provided for both core and breeder sub-assemblies

  14. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  15. Integrated systems of monitoring and environmental data processing for nuclear facilities

    International Nuclear Information System (INIS)

    Diaconu, C.; Guta, V.; Oprea, I.; Oprea, M.; Stoica, M.; Pirvu, V.; Vasilache, E.; Pirvu, I.

    2001-01-01

    The processing of huge amount of data necessary to assess the real radiological situation both in normal operational conditions and during accidents requires an efficient system of monitoring and data processing. It must be able to secure information for the complex systems of radioactivity control aiming at evaluating the nuclear accident consequences and establishing a basis for correct decision making in the field of civil protection. The integrated environmental monitoring systems are based on a number of fixed and mobile installations, a meteorological parameter measurement station, a center for data processing and a communication network, working all under the control of a real-time operation system. They collect, and process the radioactivity level and meteorological data and transmit them through the communication network. The local monitoring stations are made of detector ensembles with pressurized ionization chambers and autonomous units providing continuously information on dose and integrated rates, average values as well as the current state of the station. The meteorological data acquisition station supplies information concerning wind direction and speed, the temperature and precipitation level. The information processing center is based on a PC integrated in a local network which collects data from the radiation monitoring equipment, meteorological station as well as other work stations which process various dosimetric parameters. It is connected to Internet, so ensuring fast transfer of information towards interested authorities. The communication network consists in a local or extended Ethernet network, radio or serial connections for radioactivity level monitoring units which can be stationary, portable or mobile. Requirements raised by the application of geographic information system (GIS) and the real time operation system (QNX) ensuring multiuser and multitask operations are discussed

  16. Integrated Visualisation and Description of Complex Systems

    National Research Council Canada - National Science Library

    Goodburn, D

    1999-01-01

    ... on system topographies and feature overlays. System information from the domain's information space is filtered and integrated into a Composite Systems Model that provides a basis for consistency and integration between all system views...

  17. Safety Analysis for Power Reactor Protection System

    International Nuclear Information System (INIS)

    Eisawy, E.A.; Sallam, H.

    2012-01-01

    The main function of a Reactor Protection System (RPS) is to safely shutdown the reactor and prevents the release of radioactive materials. The purpose of this paper is to present a technique and its application for used in the analysis of safety system of the Nuclear Power Plant (NPP). A more advanced technique has been presented to accurately study such problems as the plant availability assessments and Technical Specifications evaluations that are becoming increasingly important. The paper provides the Markov model for the Reactor Protection System of the NPP and presents results of model evaluations for two testing policies in technical specifications. The quantification of the Markov model provides the probability values that the system will occupy each of the possible states as a function of time.

  18. Integrated protection of humans and the environment: a view from Japan.

    Science.gov (United States)

    Sakai, K

    2018-01-01

    Six and a half years after the accident at Fukushima Daiichi nuclear power plant, an area of existing exposure situation remains. One of the main concerns of people is the higher level of ionising radiation than before the accident, although this is not expected to have any discernible health effect. Since the accident, several 'abnormalities' in environmental organisms have been reported. It is still not clear if these abnormalities were induced by radiation. It appears that the impact of the released radioactivity has not been sufficient to threaten the maintenance of biological diversity, the conservation of species, or the health and status of natural habitats, which are the focus in environmental protection. This highlights a difference between the protection of humans and protection of the environment (individuals for humans and populations/species for the environment). The system for protection of the environment has been developed with a similar approach as the system for protection of humans. Reference Animals and Plants (RAPs) were introduced to connect exposure and doses in a way similar to that for Reference Male and Reference Female. RAPs can also be used as a tool to associate the level of radiation (dose rate) with the biological effects on an organism. A difference between the protection of humans and that of the environment was identified: an effect on humans is measured in terms of dose, and an effect on the environment is measured in terms of dose rate. In other words, protection criteria for humans are expressed in term of dose (as dose limits, dose constraints, and reference levels), whereas those for the environment are expressed in terms of dose rate (as derived consideration reference levels).

  19. Problems in creating enviroment and health protection systems

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Reznichenko, V.Yu.

    1981-01-01

    The problems in creating environmental and health protection systems are considered with relation to development of nuclear energetics facilities. A problem of transition from the system of detection and observation to the uniform system of environment and health protection and control is set. The objectives and problems of such a system are analyzed and the basic principles of their construction are outlined. A system conception for a fuel energetic complex is described. Usefulness of such systems in solving problems of sites of industrial objects including nuclear power industrial objects, of removal of these objects from service and etc. is shown. New requirements to medical-biological investigations on designing of such a system are discussed [ru

  20. A DSP-Based Beam Current Monitoring System for Machine Protection Using Adaptive Filtering

    International Nuclear Information System (INIS)

    J. Musson; H. Dong; R. Flood; C. Hovater; J. Hereford

    2001-01-01

    The CEBAF accelerator at Jefferson Lab is currently using an analog beam current monitoring (BCM) system for its machine protection system (MPS), which has a loss accuracy of 2 micro-amps. Recent burn-through simulations predict catastrophic beam line component failures below 1 micro-amp of loss, resulting in a blind spot for the MPS. Revised MPS requirements target an ultimate beam loss accuracy of 250 nA. A new beam current monitoring system has been developed which utilizes modern digital receiver technology and digital signal processing concepts. The receiver employs a direct-digital down converter integrated circuit, mated with a Jefferson Lab digital signal processor VME card. Adaptive filtering is used to take advantage of current-dependent burn-through rates. Benefits of such a system include elimination of DC offsets, generic algorithm development, extensive filter options, and interfaces to UNIX-based control systems