WorldWideScience

Sample records for instruments for measuring fluid properties or phenomena

  1. Advanced Instrumentation for Measuring Fluid-Structure Coupling Phenomena in the Guide Vanes Cascade of a Pump-Turbine Scale Model

    OpenAIRE

    Roth, Steven; Hasmatuchi, Vlad; Botero, Francisco; Farhat, Mohamed; Avellan, François

    2010-01-01

    In the present study, the fluid-structure coupling is investigated in the guide vanes of a pump-turbine scale model placed in one of the test rigs of the Laboratory for Hydraulic Machines (EPFL) in Lausanne. The paper focuses on the advanced instrumentation used to get reliable and complete fluid-structure coupling results. Semi-conductor strain gages are installed on three guide vanes which are especially weakened to account for stronger fluid-structure coupling phenomena. These are statical...

  2. Measurement Properties of Instruments for Measuring of Lymphedema: Systematic Review.

    Science.gov (United States)

    Hidding, Janine T; Viehoff, Peter B; Beurskens, Carien H G; van Laarhoven, Hanneke W M; Nijhuis-van der Sanden, Maria W G; van der Wees, Philip J

    2016-12-01

    Lymphedema is a common complication of cancer treatment, resulting in swelling and subjective symptoms. Reliable and valid measurement of this side effect of medical treatment is important. The purpose of this study was to provide best evidence regarding which measurement instruments are most appropriate in measuring lymphedema in its different stages. The PubMed and Web of Science databases were used, and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Clinical studies on measurement instruments assessing lymphedema were reviewed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) scoring instrument for quality assessment. Data on reliability, concurrent validity, convergent validity, sensitivity, specificity, applicability, and costs were extracted. Pooled data showed good intrarater intraclass correlation coefficients (ICCs) (.89) for bioimpedance spectroscopy (BIS) in the lower extremities and high intrarater and interrater ICCs for water volumetry, tape measurement, and perometry (.98-.99) in the upper extremities. In the upper extremities, the standard error of measurement was 3.6% (σ=0.7%) for water volumetry, 5.6% (σ=2.1%) for perometry, and 6.6% (σ=2.6%) for tape measurement. Sensitivity of tape measurement in the upper extremities, using different cutoff points, varied from 0.73 to 0.90, and specificity values varied from 0.72 to 0.78. No uniform definition of lymphedema was available, and a gold standard as a reference test was lacking. Items concerning risk of bias were study design, patient selection, description of lymphedema, blinding of test outcomes, and number of included participants. Measurement instruments with evidence for good reliability and validity were BIS, water volumetry, tape measurement, and perometry, where BIS can detect alterations in extracellular fluid in stage 1 lymphedema and the other measurement instruments can detect alterations in volume

  3. Instrumentation, measurements, and experiments in fluids

    CERN Document Server

    Rathakrishnan, E

    2007-01-01

    NEED AND OBJECTIVE OF EXPERIMENTAL STUDY Some Fluid Mechanics MeasurementsMeasurement SystemsSome of the Important Quantities Associated with FluidFlow MeasurementsFUNDAMENTALS OF FLUID MECHANICSProperties of FluidsThermodynamic PropertiesSurface TensionAnalysis of Fluid FlowBasic and Subsidiary Laws for Continuous MediaKinematics of Fluid FlowStreamlinesPotential FlowViscous FlowsGas DynamicsWIND TUNNELSLow-Speed Wind TunnelsPower Losses in a Wind TunnelHigh-Speed Wind TunnelsHypersonic TunnelsInstrume

  4. Measurement properties of adult quality-of-life measurement instruments for eczema: a systematic review.

    Science.gov (United States)

    Heinl, D; Prinsen, C A C; Deckert, S; Chalmers, J R; Drucker, A M; Ofenloch, R; Humphreys, R; Sach, T; Chamlin, S L; Schmitt, J; Apfelbacher, C

    2016-03-01

    The Harmonising Outcome Measures for Eczema (HOME) initiative has identified quality of life (QoL) as a core outcome domain to be evaluated in every eczema trial. It is unclear which of the existing QoL instruments is most appropriate for this domain. Thus, the aim of this review was to systematically assess the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in adult eczema. We conducted a systematic literature search in PubMed and Embase identifying studies on measurement properties of adult eczema QoL instruments. For all eligible studies, we assessed the adequacy of the measurement properties and the methodological quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis summarizing findings from different studies was the basis to assign four degrees of recommendation (A-D). A total of 15 articles reporting on 17 instruments were included. No instrument fulfilled the criteria for category A. Six instruments were placed in category B, meaning that they have the potential to be recommended depending on the results of further validation studies. Three instruments had poor adequacy in at least one required adequacy criterion and were therefore put in category C. The remaining eight instruments were minimally validated and were thus placed in category D. Currently, no QoL instrument can be recommended for use in adult eczema. The Quality of Life Index for Atopic Dermatitis (QoLIAD) and the Dermatology Life Quality Index (DLQI) are recommended for further validation research. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Instruments assessing attitudes toward or capability regarding self-management of osteoarthritis: a systematic review of measurement properties.

    Science.gov (United States)

    Eyles, J P; Hunter, D J; Meneses, S R F; Collins, N J; Dobson, F; Lucas, B R; Mills, K

    2017-08-01

    To make a recommendation on the "best" instrument to assess attitudes toward and/or capabilities regarding self-management of osteoarthritis (OA) based on available measurement property evidence. Electronic searches were performed in MEDLINE, EMBASE, CINAHL and PsychINFO (inception to 27 December 2016). Two reviewers independently rated measurement properties using the Consensus-based Standards for the selection of Health Measurement Instruments (COSMIN) 4-point scale. Best evidence synthesis was determined by considering COSMIN ratings for measurement property results and the level of evidence available for each measurement property of each instrument. Eight studies out of 5653 publications met the inclusion criteria, with eight instruments identified for evaluation: Multidimensional Health Locus of Control (MHLC), Perceived Behavioural Control (PBC), Patient Activation Measure (PAM), Educational Needs Assessment (ENAT), Stages of Change Questionnaire in Osteoarthritis (SCQOA), Effective Consumer Scale (EC-17) and Perceived Efficacy in Patient-Physician Interactions five item (PEPPI-5) and ten item scales. Measurement properties assessed for these instruments included internal consistency (k = 8), structural validity (k = 8), test-retest reliability (k = 2), measurement error (k = 1), hypothesis testing (k = 3) and cross-cultural validity (k = 3). No information was available for content validity, responsiveness or minimal important change (MIC)/minimal important difference (MID). The Dutch PEPPI-5 demonstrated the best measurement property evidence; strong evidence for internal consistency and structural validity but limited evidence for reliability and construct validity. Although PEPPI-5 was identified as having the best measurement properties, overall there is a poor level of evidence currently available concerning measurement properties of instruments to assess attitudes toward and/or capabilities regarding osteoarthritis self-management. Further

  6. Measurement Properties of Instruments for Measuring of Lymphedema: Systematic Review

    NARCIS (Netherlands)

    Hidding, J.T.; Viehoff, P.B.; Beurskens, C.H.G.; Laarhoven, H.W. van; Sanden, M.W. van der; Wees, P.J. van der

    2016-01-01

    BACKGROUND: Lymphedema is a common complication of cancer treatment, resulting in swelling and subjective symptoms. Reliable and valid measurement of this side effect of medical treatment is important. PURPOSE: The purpose of this study was to provide best evidence regarding which measurement

  7. Visualization and measurement of fluid phenomena using neutron radiography techniques

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi; Fujine, Shigenori; Yoneda, Kenji; Kanda, Keiji; Nishihara, Hideaki; Tsuruno, Akira; Matsubayashi, Masahito; Sobajima, Makoto; Ohtomo, Shoichi.

    1993-01-01

    This paper presents some of the results from recent work performed on the application of neutron radiography to visualization and measurement of fluid phenomena at the Research Reactor Institute of Kyoto University. Experiments have been performed on the following subjects with use of the NR systems at the Japan Research Reactor 3 and the Nuclear Safety Research Reactor of the Japan Atomic Energy Research Institute as well as the Kyoto University Research Reactor: air-water flow in rectangular ducts with 1.0 and 2.4 mm gaps, air-water flow and steam-water flow in a round tube with 4.0 mm inner diameter. The void fraction was measured by processing the images taken by the neutron radiography. The effect of several corrections in image processing was also discussed previously. It was shown that the proposed method could be useful in observing the flow regimes and measuring the void fraction of gas-liquid two-phase flow in narrow channels. (author)

  8. Evaluation of the measurement properties of symptom measurement instruments for atopic eczema: a systematic review.

    Science.gov (United States)

    Gerbens, L A A; Prinsen, C A C; Chalmers, J R; Drucker, A M; von Kobyletzki, L B; Limpens, J; Nankervis, H; Svensson, Å; Terwee, C B; Zhang, J; Apfelbacher, C J; Spuls, P I

    2017-01-01

    Symptoms have been identified as a core outcome domain for atopic eczema (AE) trials. Various instruments exist to measure symptoms in AE, but they vary in quality and there is a lack of standardization between clinical trials. Our objective was to systematically evaluate the quality of the evidence on the measurement properties of AE symptom instruments, thereby informing consensus discussions within the Harmonising Outcome Measures for Eczema (HOME) initiative regarding the most appropriate instruments for the core outcome domain symptoms. Using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist and predefined criteria for good measurement properties on identified development and validation studies of AE symptom instruments, a best evidence synthesis was performed to draw an overall conclusion on quality of the instruments and to provide recommendations. Eighteen instruments were identified and evaluated. When the quality and results of the studies were considered, only five of these instruments had sufficient validation data to consider them for the core outcome set for the core outcome domain symptoms. These were the paediatric Itch Severity Scale (ISS), Patient-Oriented Eczema Measure (POEM), Patient-Oriented SCOring Atopic Dermatitis (PO-SCORAD), Self-Administered Eczema Area and Severity Index (SA-EASI) and adapted SA-EASI. ISS (paediatric version), POEM, PO-SCORAD, SA-EASI and adapted SA-EASI are currently the most appropriate instruments and therefore have the potential to be recommended as core symptom instrument in future clinical trials. These findings will be utilized for the development of a core outcome set for AE. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. An instrument for the measurement of road surface reflection properties

    DEFF Research Database (Denmark)

    Corell, Dennis Dan; Sørensen, K.

    2017-01-01

    surfaces in use have changed - for instance to road surface types with less noise from wheel passages. Because of this, a co-operation between the road administrations of the Nordic countries (abbreviated NMF) decided to construct a portable instrument to be used on selections of traffic roads within......Road surface reflection data in the form of standard r-tables serve as input for design calculations of road lighting installations on traffic roads. However, in several countries the use of the standard r-tables has not been verified by measurement in a long period of time, while the types of road...

  10. Heat Transfer Phenomena of Supercritical Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Krau, Carmen Isabella; Kuhn, Dietmar; Schulenberg, Thomas [Forschungszentrum Karlsruhe, Institute for Nuclear and Energy Technologies, 76021 Karlsruhe (Germany)

    2008-07-01

    In concepts for supercritical water cooled reactors, the reactor core is cooled and moderated by water at supercritical pressures. The significant temperature dependence of the fluid properties of water requires an exact knowledge of the heat transfer mechanism to avoid fuel pin damages. Near the pseudo-critical point a deterioration of heat transfer might happen. Processes, that take place in this case, are not fully understood and are due to be examined systematically. In this paper a general overview on the properties of supercritical water is given, experimental observations of different authors will be reviewed in order to identify heat transfer phenomena and onset of occurrence. The conceptional design of a test rig to investigate heat transfer in the boundary layer will be discussed. Both, water and carbon dioxide, may serve as operating fluids. The loop, including instrumentation and safety devices, is shown and suitable measuring methods are described. (authors)

  11. Measurement properties of adult quality-of-life measurement instruments for eczema: protocol for a systematic review.

    Science.gov (United States)

    Apfelbacher, Christian J; Heinl, Daniel; Prinsen, Cecilia A C; Deckert, Stefanie; Chalmers, Joanne; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Chamlin, Sarah; Schmitt, Jochen

    2015-04-16

    Eczema is a common chronic or chronically relapsing skin disease that has a substantial impact on quality of life (QoL). By means of a consensus-based process, the Harmonising Outcome Measures in Eczema (HOME) initiative has identified QoL as one of the four core outcome domains to be assessed in all eczema trials (Allergy 67(9):1111-7, 2012). Various measurement instruments exist to measure QoL in adults with eczema, but there is a great variability in both content and quality (for example, reliability and validity) of the instruments used, and it is not always clear if the best instrument is being used. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in adults with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for adults with eczema. Medline via PubMed and EMBASE will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for adult patients with eczema. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties, and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study has investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing QoL instruments in

  12. Measurement properties of quality of life measurement instruments for infants, children and adolescents with eczema: protocol for a systematic review.

    Science.gov (United States)

    Heinl, Daniel; Prinsen, Cecilia A C; Drucker, Aaron M; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Flohr, Carsten; Apfelbacher, Christian

    2016-02-09

    Eczema is a common chronic or chronically relapsing, inflammatory skin disease that exerts a substantial negative impact on quality of life (QoL). The Harmonising Outcome Measures for Eczema (HOME) initiative has used a consensus-based process which identified QoL as one of the four core outcome domains to be assessed in all eczema clinical trials. A number of measurement instruments exist to measure QoL in infants, children, and adolescents with eczema, and there is a great variability in both content and quality of the instruments used. Therefore, the objective of the proposed research is to comprehensively and systematically assess the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in infants, children, and adolescents with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for infants, children, and adolescents with eczema. A systematic literature search will be carried out in MEDLINE via PubMed and EMBASE using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for infants, children, and adolescents with eczema. Two reviewers will independently perform eligibility assessment and data abstraction. Evidence tables will be used to record study characteristics, instrument characteristics, measurement properties, and interpretability. The adequacy of the measurement properties will be assessed using predefined criteria. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist will be used to evaluate the methodological quality of included studies. A best evidence synthesis will be undertaken if more than one study has examined a particular measurement property. The proposed systematic review will yield a comprehensive assessment

  13. An integrative review of literature examining psychometric properties of instruments measuring anxiety or fear in hospitalized children.

    Science.gov (United States)

    Foster, Roxie L; Park, Jeong-hwan

    2012-06-01

    Anxiety and fear are among the most frequently reported emotional responses to hospitalization and are known to be contributing factors to pain and other negative patient outcomes. The first step in confronting unnecessary anxiety and fear is to identify valid and clinically feasible assessment instruments. The purpose of this paper is to review and evaluate instruments that measure children's fear or anxiety associated with hospitalization or painful procedures. A search was conducted of published English-language literature from 1980 through 2010 with the use of Ovid Health and Psychosocial Instruments, Medline, Nursing/Academic Edition, Cinahl, and Google Scholar. Inclusion criteria specified that the self-report instrument: 1) was developed in English; 2) was developed for and/or widely used with hospitalized children or children undergoing medical procedures or treatment; and 3) had research evidence of psychometric properties from at least five different studies. A comprehensive review of the literature revealed only five fear or anxiety instruments with adequate testing for evaluation of reliability and validity. Although all instruments have beginning psychometric adequacy, no one tool stands out as superior to the others. Therefore, we recommend that researchers and clinicians exercise caution in choosing assessment instruments, balancing potential strengths with reported limitations. Using more than one tool (triangulating) may be one way to achieve more credible results. Knowledge of credible existing instruments alerts us to what is possible today and to the imperative for research that will improve communication with children tomorrow. Copyright © 2012 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  14. Means and Method for Measurement of Drilling Fluid Properties

    Science.gov (United States)

    Lysyannikov, A.; Kondrashov, P.; Pavlova, P.

    2016-06-01

    The paper addresses the problem on creation of a new design of the device for determining rheological parameters of drilling fluids and the basic requirements which it must meet. The key quantitative parameters that define the developed device are provided. The algorithm of determining the coefficient of the yield point from the rheological Shvedov- Bingam model at a relative speed of rotation of glasses from the investigated drilling fluid of 300 and 600 rpm is presented.

  15. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    -centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross-cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less-studied constructs and domains to become part of newly developed instruments. © 2016 Milbank Memorial Fund.

  16. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    integration (33%) and patient‐centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross‐cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Conclusions Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less‐studied constructs and domains to become part of newly developed instruments. PMID:27995711

  17. Measurement properties of quality-of-life measurement instruments for infants, children and adolescents with eczema: a systematic review.

    Science.gov (United States)

    Heinl, D; Prinsen, C A C; Sach, T; Drucker, A M; Ofenloch, R; Flohr, C; Apfelbacher, C

    2017-04-01

    Quality of life (QoL) is one of the core outcome domains identified by the Harmonising Outcome Measures for Eczema (HOME) initiative to be assessed in every eczema trial. There is uncertainty about the most appropriate QoL instrument to measure this domain in infants, children and adolescents. To systematically evaluate the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in infants, children and adolescents with eczema. A systematic literature search in PubMed and Embase, complemented by a thorough hand search of reference lists, retrieved studies on measurement properties of eczema QoL instruments for infants, children and adolescents. For all eligible studies, we judged the adequacy of the measurement properties and the methodological study quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Results from different studies were summarized in a best-evidence synthesis and formed the basis to assign four degrees of recommendation. Seventeen articles, three of which were found by hand search, were included. These 17 articles reported on 24 instruments. No instrument can be recommended for use in all eczema trials because none fulfilled all required adequacy criteria. With adequate internal consistency, reliability and hypothesis testing, the U.S. version of the Childhood Atopic Dermatitis Impact Scale (CADIS), a proxy-reported instrument, has the potential to be recommended depending on the results of further validation studies. All other instruments, including all self-reported ones, lacked significant validation data. Currently, no QoL instrument for infants, children and adolescents with eczema can be highly recommended. Future validation research should primarily focus on the CADIS, but also attempt to broaden the evidence base for the validity of self-reported instruments. © 2016 British Association of Dermatologists.

  18. An instrument for the measurement of road surface reflection properties

    DEFF Research Database (Denmark)

    Corell, Dennis Dan; Sørensen, K.

    2017-01-01

    Road surface reflection data in the form of standard r-tables serve as input for design calculations of road lighting installations on traffic roads. However, in several countries the use of the standard r-tables has not been verified by measurement in a long period of time, while the types of road...

  19. Self-administered health literacy instruments for people with diabetes: systematic review of measurement properties.

    Science.gov (United States)

    Lee, Eun-Hyun; Kim, Chun-Ja; Lee, Jiyeon; Moon, Seung Hei

    2017-09-01

    The aims of this study were to identify all available self-administered instruments measuring health literacy in people with diabetes and to determine the current instrument that is the most appropriate for applying to this population in both practice and research. A systematic review of measurement properties. MEDLINE, EMBASE and CINAHL electronic databases from their inception up to 28 March 2016. The methodological quality of each included study was assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. The reported results for measurement properties in the studies were assessed according to Terwee's quality criteria. Thirteen self-administered instruments measuring health literacy in people with diabetes were identified, of which six (44%) were diabetes-specific instruments. The instruments that covered the broadest contents of health literacy were the Health Literacy Scale and Health Literacy Questionnaire. The (test-retest) reliability, measurement error and responsiveness were not evaluated for any instrument, while internal consistency and hypothesis testing validity were the most frequently assessed measurement properties. With the current evidence, the Health Literacy Scale may be the most appropriate instrument for patients with diabetes in practice and research. However, the structural validity of this scale needs to be further established, particularly in other language versions. It is also recommended to use the Diabetes Numeracy Test-15 along with the Health Literacy Scale to complement the lack of numeracy measures in the Health Literacy Scale. © 2017 John Wiley & Sons Ltd.

  20. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  1. Systematic review of measurement properties of self-reported instruments for evaluating self-care in adults.

    Science.gov (United States)

    Matarese, Maria; Lommi, Marzia; De Marinis, Maria Grazia

    2017-06-01

    The aims of this study were as follows: to identify instruments developed to assess self-care in healthy adults; to determine the theory on which they were based; their validity and reliability properties and to synthesize the evidence on their measurement properties. Many instruments have been developed to assess self-care in many different populations and conditions. Clinicians and researchers should select the most appropriate self-care instrument based on the knowledge of their measurement properties. Systematic review of measurement instruments according to the protocol recommended by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. PubMed, Embase, PsycINFO, Scopus and CINAHL databases were searched from inception to December 2015. Studies testing measurement properties of self-report instruments assessing self-care in healthy adults, published in the English language and in peer review journals were selected. Two reviewers independently appraised the methodological quality of the studies with the COSMIN checklist and the quality of results using specific quality criteria. Twenty-six articles were included in the review testing the measurement properties of nine instruments. Seven instruments were based on Orem's Self-care theory. Not all the measurement properties were evaluated for the identified instruments. No self-care instrument showed strong evidence supporting the evaluated measurement properties. Despite the development of several instruments to assess self-care in the adult population, no instrument can be fully recommended to clinical nurses and researchers. Further studies of high methodological quality are needed to confirm the measurement properties of these instruments. © 2016 John Wiley & Sons Ltd.

  2. Research and development of thermal-fluid measuring instrument

    International Nuclear Information System (INIS)

    Tuzla, K.; Chen, J.C.

    1991-01-01

    The goal of this program is to develop an instrument to measure the time-fraction of liquid contact in the transition and film boiling regimes for flow within a vertical tube. The work was carried out at Lehigh University between February 15, 1989 to February 15, 1991. The instrument to measure time-fraction of liquid contact was successfully developed and tested

  3. Ultrasonic techniques for measuring physical properties of fluids in harsh environments

    Science.gov (United States)

    Pantea, Cristian

    Ultrasonic-based measurement techniques, either in the time domain or in the frequency domain, include a wide range of experimental methods for investigating physical properties of materials. This discussion is specifically focused on ultrasonic methods and instrumentation development for the determination of liquid properties at conditions typically found in subsurface environments (in the U.S., more than 80% of total energy needs are provided by subsurface energy sources). Such sensors require materials that can withstand harsh conditions of high pressure, high temperature and corrosiveness. These include the piezoelectric material, electrically conductive adhesives, sensor housings/enclosures, and the signal carrying cables, to name a few. A complete sensor package was developed for operation at high temperatures and pressures characteristic to geothermal/oil-industry reservoirs. This package is designed to provide real-time, simultaneous measurements of multiple physical parameters, such as temperature, pressure, salinity and sound speed. The basic principle for this sensor's operation is an ultrasonic frequency domain technique, combined with transducer resonance tracking. This multipurpose acoustic sensor can be used at depths of several thousand meters, temperatures up to 250 °C, and in a very corrosive environment. In the context of high precision measurement of sound speed, the determination of acoustic nonlinearity of liquids will also be discussed, using two different approaches: (i) the thermodynamic method, in which precise and accurate frequency domain sound speed measurements are performed at high pressure and high temperature, and (ii) a modified finite amplitude method, requiring time domain measurements of the second harmonic at room temperature. Efforts toward the development of an acoustic source of collimated low-frequency (10-150 kHz) beam, with applications in imaging, will also be presented.

  4. Visualization and measurement of thermo-fluid phenomena by using neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mishima, Kaichiro [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.

    1998-03-01

    Recently, neutron radiography is rapidly expanding its application to various fields incollaboration with the development of electronic imaging techniques. Particularly, in the field of thermal and fluid engineering, it has drawn much attention as an innovative and non-intrusive method for fluid-visualization and measurement using neutron beam as a probe. In this paper, some examples of applications are introduced on the high frame-rate imaging, quantification method (especially, determination of void fraction), and multidimensional measurement which are much interested in fluid measurement in relation to light water reactor safety and thermohydraulics. (author)

  5. Visualization and measurement of thermo-fluid phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Mishima, Kaichiro

    1998-01-01

    Recently, neutron radiography is rapidly expanding its application to various fields incollaboration with the development of electronic imaging techniques. Particularly, in the field of thermal and fluid engineering, it has drawn much attention as an innovative and non-intrusive method for fluid-visualization and measurement using neutron beam as a probe. In this paper, some examples of applications are introduced on the high frame-rate imaging, quantification method (especially, determination of void fraction), and multidimensional measurement which are much interested in fluid measurement in relation to light water reactor safety and thermohydraulics. (author)

  6. Systematic Review of Measurement Property Evidence for 8 Financial Management Instruments in Populations With Acquired Cognitive Impairment.

    Science.gov (United States)

    Engel, Lisa; Chui, Adora; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2018-03-07

    To critically appraise the measurement property evidence (ie, psychometric) for 8 observation-based financial management assessment instruments. Seven databases were searched in May 2015. Two reviewers used an independent decision-agreement process to select studies of measurement property evidence relevant to populations with adulthood acquired cognitive impairment, appraise the quality of the evidence, and extract data. Twenty-one articles were selected. This review used the COnsensus-based Standards for the selection of health Measurement Instruments review guidelines and 4-point tool to appraise evidence. After appraising the methodologic quality, the adequacy of results and volume of evidence per instrument were synthesized. Measurement property evidence with high risk of bias was excluded from the synthesis. The volume of measurement property evidence per instrument is low; most instruments had 1 to 3 included studies. Many included studies had poor methodologic quality per measurement property evidence area examined. Six of the 8 instruments reviewed had supporting construct validity/hypothesis-testing evidence of fair methodologic quality. There is a dearth of acceptable quality content validity, reliability, and responsiveness evidence for all 8 instruments. Rehabilitation practitioners assess financial management functions in adults with acquired cognitive impairments. However, there is limited published evidence to support using any of the reviewed instruments. Practitioners should exercise caution when interpreting the results of these instruments. This review highlights the importance of appraising the quality of measurement property evidence before examining the adequacy of the results and synthesizing the evidence. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. A strain-controlled RheoSANS instrument for the measurement of the microstructural, electrical, and mechanical properties of soft materials

    Science.gov (United States)

    Richards, Jeffrey J.; Wagner, Norman J.; Butler, Paul D.

    2017-10-01

    In situ measurements are an increasingly important tool to inform the complex relationship between nanoscale properties and macroscopic material measurements. Knowledge of these phenomena can be used to develop new materials to meet the performance demands of next generation technologies. Conductive complex fluids have emerged as an area of research where the electrical and mechanical properties are key design parameters. To study the relationship between microstructure, conductivity, and rheology, we have developed a small angle neutron scattering (SANS) compatible Couette rheological geometry capable of making impedance spectroscopy measurements under continuous shear. We have also mounted this geometry on a commercial strain controlled rheometer with a modified forced convection oven. In this manuscript, we introduce the simultaneous measurement of impedance spectroscopy, rheological properties and SANS data. We describe the validation of this dielectric RheoSANS instrument and demonstrate its operation using two systems—an ion gel comprising Pluronic® surfactant and ionic liquid, ethyl-ammonium nitrate, and poly(3-hexylthiophene) organogel prepared in a mixture of hexadecane and dichlorobenzene. In both systems, we use this new measurement capability to study the microstructural state of these materials under two different protocols. By monitoring their dielectric rheology at the same time as the SANS measurement, we demonstrate the capacity to directly probe structure-property relationships inherent to the macroscopic material response.

  8. PHENOMENA AND BASIC MACROECONOMIC INDICATORS FOR MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    PAULINA CATANA

    2010-01-01

    Full Text Available Macroeconomics is a separate discipline of the Economy that studies and analyzes the behaviour of economic aggregates and significant average, such as price level, national income, national income potential, the gap GDP, employment and unemployment of labour, investment and export of the whole economy. We can accuse to Macroeconomics that it deals also with the average price of all goods and services, not the prices of certain products. These aggregates result from economic behaviour of certain groups (governments, companies, consumers in the course of their activities on different markets. But why does it need Macroeconomics? Experts say that we need this separate discipline because there are certain forces that affect the broader economy globally, which can not be understood only by analyzing individual economic phenomena, individual products or markets.

  9. Instruments for meteorological measurement

    International Nuclear Information System (INIS)

    1983-08-01

    The Fundamental Safety Rules applicable to certain types of nuclear installation are intended to clarify the conditions of which observance, for the type of installation concerned and for the subject that they deal with, is considered as equivalent to compliance with regulatory French technical practice. These Rules should facilitate safety analysises and the clear understanding between persons interested in matters related to nuclear safety. They in no way reduce the operator's liability and pose no obstacle to statutory provisions in force. For any installation to which a Fundamental Safety Rule applies according to the foregoing paragraph, the operator may be relieved from application of the Rule if he shows proof that the safety objectives set by the Rule are attained by other means that he proposes within the framework of statutory procedures. Furthermore, the Central Service for the Safety of Nuclear Installations reserves the right at all times to alter any Fundamental Safety Rule, as required, should it deem this necessary, while specifying the applicability conditions. This present rule has for objective to determine the means for meteorological measurement near a site of nuclear facility in which there is not a PWR power plant [fr

  10. Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

    Science.gov (United States)

    Bivolaru, Daniel; Lee, Joseph W.; Jones, Stephen B.; Tedder, Sarah A.; Danehy, Paul M.; Weikl, M. C.; Magnotti, G.; Cutler, Andrew D.

    2007-01-01

    This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

  11. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study.

    Science.gov (United States)

    Mokkink, Lidwine B; Terwee, Caroline B; Patrick, Donald L; Alonso, Jordi; Stratford, Paul W; Knol, Dirk L; Bouter, Lex M; de Vet, Henrica C W

    2010-05-01

    Aim of the COSMIN study (COnsensus-based Standards for the selection of health status Measurement INstruments) was to develop a consensus-based checklist to evaluate the methodological quality of studies on measurement properties. We present the COSMIN checklist and the agreement of the panel on the items of the checklist. A four-round Delphi study was performed with international experts (psychologists, epidemiologists, statisticians and clinicians). Of the 91 invited experts, 57 agreed to participate (63%). Panel members were asked to rate their (dis)agreement with each proposal on a five-point scale. Consensus was considered to be reached when at least 67% of the panel members indicated 'agree' or 'strongly agree'. Consensus was reached on the inclusion of the following measurement properties: internal consistency, reliability, measurement error, content validity (including face validity), construct validity (including structural validity, hypotheses testing and cross-cultural validity), criterion validity, responsiveness, and interpretability. The latter was not considered a measurement property. The panel also reached consensus on how these properties should be assessed. The resulting COSMIN checklist could be useful when selecting a measurement instrument, peer-reviewing a manuscript, designing or reporting a study on measurement properties, or for educational purposes.

  12. Instrumentation for analytical scale supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2015-11-20

    Analytical scale supercritical fluid chromatography (SFC) is largely a sub-discipline of high performance liquid chromatography (HPLC), in that most of the hardware and software can be used for either technique. The aspects that separate the 2 techniques stem from the use of carbon dioxide (CO2) as the main component of the mobile phase in SFC. The high compressibility and low viscosity of CO2 mean that pumps, and autosamplers designed for HPLC either need to be modified or an alternate means of dealing with compressibility needs to be found. The inclusion of a back pressure regulator and a high pressure flow cell for any UV-Vis detector are also necessary. Details of the various approaches, problems and solutions are described. Characteristics, such as adiabatic vs. isothermal compressibility, thermal gradients, and refractive index issues are dealt with in detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Mixed Fluid Conditions: Capillary Phenomena

    KAUST Repository

    Santamarina, Carlos; Sun, Zhonghao

    2017-01-01

    Mixed fluid phenomena in porous media have profound implications on soil-atmosphere interaction, energy geotechnology, environmental engineering and infrastructure design. Surface tension varies with pressure, temperature, solute concentration

  14. Patient perspective workshop: moving towards OMERACT guidelines for choosing or developing instruments to measure patient-reported outcomes.

    Science.gov (United States)

    Kirwan, John R; Fries, James F; Hewlett, Sarah E; Osborne, Richard H; Newman, Stanton; Ciciriello, Sabina; van de Laar, Mart A; Dures, Emma; Minnock, Patricia; Heiberg, Turid; Sanderson, Tessa C; Flurey, Caroline A; Leong, Amy L; Montie, Pamela; Richards, Pam

    2011-08-01

    The workshop Choosing or Developing Instruments held at the Outcome Measures in Rheumatology (OMERACT) 10 meeting was designed to help participants think about the underlying methods of instrument development. Conference pre-reading material and 3 brief introductory presentations elaborated the issues, and participants broke into discussion groups before reconvening to share insights, engage in a more general discussion of the issues, and vote on recommendations. Tradeoffs between using current imperfect measures and the long and complex process of developing new instruments were considered, together with the need for rigor in patient-reported outcome (PRO) instrument development. The main considerations for PRO instrument development were listed and a research agenda for action produced. As part of the agenda for action, it is recommended that researchers and patient partners work together to tackle these issues, and that OMERACT bring forward proposals for acceptable instrument development protocols that would meet an enhanced "Truth" statement in the OMERACT Filter.

  15. Instruments measuring family or caregiver burden in severe mental illness

    NARCIS (Netherlands)

    Schene, A. H.; Tessler, R. C.; Gamache, G. M.

    1994-01-01

    The consequences of psychiatric disorders for family members, usually called family or caregiver burden, have been studied during the last 4 decades. During this period a variety of instruments have been developed to measure the impact of mental illness on family members, but not all instruments

  16. Instrument for measuring flow velocities

    International Nuclear Information System (INIS)

    Griffo, J.

    1977-01-01

    The design described here means to produce a 'more satisfying instrument with less cost' than comparable instruments known up to now. Instead of one single turbine rotor, two similar ones but with opposite blade inclination and sense of rotation are to be used. A cylindrical measuring body is carrying in its axis two bearing blocks whose shape is offering little flow resistance. On the shaft, supported by them, the two rotors run in opposite direction a relatively small axial distance apart. The speed of each rotor is picked up as pulse recurrence frequency by a transmitter and fed to an electronic measuring unit. Measuring errors as they are caused for single rotors by turbulent flow, profile distortion of the velocity, or viscous flow are to be eliminated by means of the contrarotating turbines and the subsequently added electronic unit, because in these cases the adulterating increase of the angular velocity of one rotor is compensated by a corresponding deceleration of the other rotor. The mean value then indicated by the electronic unit has high accurancy of measurement. (RW) [de

  17. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  18. Assessment of sexual difficulties associated with multi-modal treatment for cervical or endometrial cancer: A systematic review of measurement instruments.

    Science.gov (United States)

    White, Isabella D; Sangha, Amrit; Lucas, Grace; Wiseman, Theresa

    2016-12-01

    Practitioners and researchers require an outcome measure that accurately identifies the range of common treatment-induced changes in sexual function and well-being experienced by women after cervical or endometrial cancer. This systematic review critically appraised the measurement properties and clinical utility of instruments validated for the measurement of female sexual dysfunction (FSD) in this clinical population. A bibliographic database search for questionnaire development or validation papers was completed and methodological quality and measurement properties of selected studies rated using the Consensus-based Standards for the selection of health Measurement Instrument (COSMIN) checklist. 738 articles were screened, 13 articles retrieved for full text assessment and 7 studies excluded, resulting in evaluation of 6 papers; 2 QoL and 4 female sexual morbidity measures. Five of the six instruments omitted one or more dimension of female sexual function and only one instrument explicitly measured distress associated with sexual changes as per DSM V (APA 2013) diagnostic criteria. None of the papers reported measurement error, responsiveness data was available for only two instruments, three papers failed to report on criterion validity, and test-retest reliability reporting was inconsistent. Heterosexual penile-vaginal intercourse remains the dominant sexual activity focus for sexual morbidity PROMS terminology and instruments lack explicit reference to solo or non-coital sexual expression or validation in a non-heterosexual sample. Four out of six instruments included mediating treatment or illness items such as vaginal changes, menopause or altered body image. Findings suggest that the Female Sexual Function Index (FSFI) remains the most robust sexual morbidity outcome measure, for research or clinical use, in sexually active women treated for cervical or endometrial cancer. Development of an instrument that measures sexual dysfunction in women who are

  19. Two-fluid modeling of thermal-hydraulic phenomena for best-estimate LWR safety analysis

    International Nuclear Information System (INIS)

    Yadigaroglu, G.; Andreani, M.

    1989-01-01

    Two-fluid formulation of the conservation equations has allowed modelling of the two-phase flow and heat transfer phenomena and situations involving strong departures in thermal and velocity equilibrium between the phases. The paper reviews the state of the art in modelling critical flows, and certain phase separation phenomena, as well as post-dryout heat transfer situations. Although the two-fluid models and the codes have the potential for correctly modelling such situations, this potential has not always been fully used in practice. (orig.)

  20. Nuclear instrumentation for radiation measurement

    International Nuclear Information System (INIS)

    Madan, V.K.

    2012-01-01

    Nuclear radiation cannot be detected by human senses. Nuclear detectors and associated electronics facilitate detection and measurement of different types of radiation like alpha particles, beta particles, gamma radiation, and detection of neutrons. Nuclear instrumentation has evolved greatly since the discovery of radioactivity. There has been tremendous advancement in detector technology, electronics, computer technology, and development of efficient algorithms and methods for spectral processing to extract precisely qualitative and quantitative information of the radiation. Various types of detectors and nuclear instruments are presently available and are used for different applications. This paper describes nuclear radiation, its detection and measurement and associated electronics, spectral information extraction, and advances in these fields. The paper also describes challenges in this field

  1. Instruments to assess self-care among healthy children: A systematic review of measurement properties.

    Science.gov (United States)

    Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa

    2017-12-01

    To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.

  2. Advanced computational multi-fluid dynamics: a new model for understanding electrokinetic phenomena in porous media

    Science.gov (United States)

    Gulamali, M. Y.; Saunders, J. H.; Jackson, M. D.; Pain, C. C.

    2009-04-01

    We present results from a new computational multi-fluid dynamics code, designed to model the transport of heat, mass and chemical species during flow of single or multiple immiscible fluid phases through porous media, including gravitational effects and compressibility. The model also captures the electrical phenomena which may arise through electrokinetic, electrochemical and electrothermal coupling. Building on the advanced computational technology of the Imperial College Ocean Model, this new development leads the way towards a complex multiphase code using arbitrary unstructured and adaptive meshes, and domains decomposed to run in parallel over a cluster of workstations or a dedicated parallel computer. These facilities will allow efficient and accurate modelling of multiphase flows which capture large- and small-scale transport phenomena, while preserving the important geology and/or surface topology to make the results physically meaningful and realistic. Applications include modelling of contaminant transport in aquifers, multiphase flow during hydrocarbon production, migration of carbon dioxide during sequestration, and evaluation of the design and safety of nuclear reactors. Simulations of the streaming potential resulting from multiphase flow in laboratory- and field-scale models demonstrate that streaming potential signals originate at fluid fronts, and at geologic boundaries where fluid saturation changes. This suggests that downhole measurements of streaming potential may be used to inform production strategies in oil and gas reservoirs. As water encroaches on an oil production well, the streaming-potential signal associated with the water front encompasses the well even when the front is up to 100 m away, so the potential measured at the well starts to change significantly relative to a distant reference electrode. Variations in the geometry of the encroaching water front could be characterized using an array of electrodes positioned along the well

  3. Stability analysis on the free surface phenomena of a magnetic fluid for general use

    International Nuclear Information System (INIS)

    Mizuta, Yo

    2011-01-01

    This paper presents an analysis for elucidating a variety of physical processes on the interface (free surface) of magnetic fluid. The present analysis is composed of the magnetic and the fluid analysis, both of which have no limitations concerning the interface elevation or its profile. The magnetic analysis provides rigorous interface magnetic field under arbitrary distributions of applied magnetic field. For the fluid analysis, the equation for interface motion includes all nonlinear effects. Physical quantities such as the interface magnetic field or the interface stresses, obtained first as the wavenumber components, facilitate confirming the relations with those by the conventional theoretical analyses. The nonlinear effect is formulated as the nonlinear mode coupling between the interface profile and the applied magnetic field. The stability of the horizontal interface profile is investigated by the dispersion relation, and summarized as the branch line. Furthermore, the balance among the spectral components of the interface stresses are shown, within the sufficient range of the wavenumber space. - Research Highlights: → General, rigorous but compact analysis for free surface phenomena is shown. → Analysis is applied without limitations on the interface elevation or its profile. → Nonlinear effects are formulated as the nonlinear mode coupling. → Bifurcation of stability is summarized as the branch line. → Balance among the interface stresses are shown in the wavenumber space.

  4. Informal caregiving in COPD: A systematic review of instruments and their measurement properties.

    Science.gov (United States)

    Cruz, Joana; Marques, Alda; Machado, Ana; O'Hoski, Sachi; Goldstein, Roger; Brooks, Dina

    2017-07-01

    Increasing symptoms and activity restriction associated with COPD progression greatly impact on the lives of their informal caregivers, who play a vital role in maintaining their health. An understanding of this impact is important for clinicians to support caregivers and maintain a viable patient environment at home. This systematic review aimed to identify the instruments commonly used to assess informal caregiving in COPD and describe their measurement properties in this population. Searches were conducted in PubMed, Scopus, Web of Science, CINAHL and PsycINFO and in references of key articles, until November 2016 (PROSPERO: CRD42016041401). Instruments used to assess the impact of COPD on caregivers were identified and their properties described. Quality of studies was rated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Quality of the measurement properties of instruments was rated as 'positive', 'negative' or 'indeterminate'. Patients cared for, had moderate to very severe COPD and the sample of caregivers ranged from 24 to 406. Thirty-five instruments were used in fifty studies to assess caregivers' psychological status and mood (9 instruments), burden/distress (12 instruments), quality of life (5 instruments) or other (9 instruments). Eighteen studies assessed the measurement properties of 21 instruments, most commonly hypothesis testing (known validity) and internal consistency. Study quality varied from 'poor' to 'fair' and with many properties rated as 'indeterminate'. Although several instruments have been used to assess the impact of COPD on caregivers, an increased understanding of their properties is needed before their widespread implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review.

    Science.gov (United States)

    Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea

    2016-03-15

    While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  6. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review

    Directory of Open Access Journals (Sweden)

    Elaine Lima

    2016-01-01

    Full Text Available Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  7. The measurement of collaboration within healthcare settings: a systematic review of measurement properties of instruments.

    Science.gov (United States)

    Walters, Stephen John; Stern, Cindy; Robertson-Malt, Suzanne

    2016-04-01

    There is a growing call by consumers and governments for healthcare to adopt systems and approaches to care to improve patient safety. Collaboration within healthcare settings is an important factor for improving systems of care. By using validated measurement instruments a standardized approach to assessing collaboration is possible, otherwise it is only an assumption that collaboration is occurring in any healthcare setting. The objective of this review was to evaluate and compare measurement properties of instruments that measure collaboration within healthcare settings, specifically those which have been psychometrically tested and validated. Participants could be healthcare professionals, the patient or any non-professional who contributes to a patient's care, for example, family members, chaplains or orderlies. The term participant type means the designation of any one participant; for example 'nurse', 'social worker' or 'administrator'. More than two participant types was mandatory. The focus of this review was the validity of tools used to measure collaboration within healthcare settings. The types of studies considered for inclusion were validation studies, but quantitative study designs such as randomized controlled trials, controlled trials and case studies were also eligible for inclusion. Studies that focused on Interprofessional Education, were published as an abstract only, contained patient self-reporting only or were not about care delivery were excluded. The outcome of interest was validation and interpretability of the instrument being assessed and included content validity, construct validity and reliability. Interpretability is characterized by statistics such as mean and standard deviation which can be translated to a qualitative meaning. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. The databases searched included PubMed, CINAHL, Embase, Cochrane Central

  8. Mixed Fluid Conditions: Capillary Phenomena

    KAUST Repository

    Santamarina, Carlos

    2017-07-06

    Mixed fluid phenomena in porous media have profound implications on soil-atmosphere interaction, energy geotechnology, environmental engineering and infrastructure design. Surface tension varies with pressure, temperature, solute concentration, and surfactant concentration; on the other hand, the contact angle responds to interfacial tensions, surface topography, invasion velocity, and chemical interactions. Interfaces are not isolated but interact through the fluid pressure and respond to external fields. Jumps, snap-offs and percolating wetting liquids along edges and crevices are ubiquitous in real, non-cylindrical porous networks. Pore- and macroscale instabilities together with pore structure variability-and-correlation favor fluid trapping and hinder recovery efficiency. The saturation-pressure characteristic curve is affected by the saturation-history, flow-rate, the mechanical response of the porous medium, and time-dependent reactive and diffusive processes; in addition, there are salient differences between unsaturation by internal gas nucleation and gas invasion. Capillary forces add to other skeletal forces in the porous medium and can generate open-mode discontinuities when the capillary entry pressure is high relative to the effective stress. Time emerges as an important variable in mixed-fluid conditions and common quasi-static analyses may fail to capture the system response.

  9. Investigation of physical properties of porous rocks and fluid flow phenomena in porous media using computer assisted tomography

    International Nuclear Information System (INIS)

    Kantzas, A.

    1990-01-01

    Computer assisted tomography is becoming a very attractive tool for petroleum engineers. The method can give an image of a core in two or three dimensions with a very fine resolution and high accuracy. The image data can be processed to give information about the physical properties of the core (density, porosity, mineralogy, heterogeneities) and the fluids within the core (saturation and saturation profiles). This paper presents a software package that uses the CAT scanner output data as input for petrographic and dynamic modelling of a porous rock. Core samples up to 10 cm in diameter are scanned at different x-ray energy levels using an EMI CT5005 full body scanner. The scanner computer is producing an array of normalized linear attenuation coefficients per scanned slice. The resolution is 0.75 mm x 0.75 mm while the slice thickness can vary from 15 mm down to 1 mm depending on the bulk density and size of the sample. The developed package analyzes the CAT scanner data for bulk and grain density, effective atomic number, static and dynamic porosity and fluid saturations for up to three fluids present. The capabilities and limitations of the presented algorithm are discussed and characteristic examples are presented

  10. Integrated intelligent instruments using supercritical fluid technology for soil analysis

    International Nuclear Information System (INIS)

    Liebman, S.A.; Phillips, C.; Fitzgerald, W.; Levy, E.J.

    1994-01-01

    Contaminated soils pose a significant challenge for characterization and remediation programs that require rapid, accurate and comprehensive data in the field or laboratory. Environmental analyzers based on supercritical fluid (SF) technology have been designed and developed for meeting these global needs. The analyzers are designated the CHAMP Systems (Chemical Hazards Automated Multimedia Processors). The prototype instrumentation features SF extraction (SFE) and on-line capillary gas chromatographic (GC) analysis with chromatographic and/or spectral identification detectors, such as ultra-violet, Fourier transform infrared and mass spectrometers. Illustrations are given for a highly automated SFE-capillary GC/flame ionization (FID) configuration to provide validated screening analysis for total extractable hydrocarbons within ca. 5--10 min, as well as a full qualitative/quantitative analysis in 25--30 min. Data analysis using optional expert system and neural networks software is demonstrated for test gasoline and diesel oil mixtures in this integrated intelligent instrument approach to trace organic analysis of soils and sediments

  11. Development of measurement capabilities for the thermophysical properties of energy-related fluids. Annual report, December 1, 1992--November 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kayser, R.F.

    1993-08-13

    The measurement capabilities to be developed include new apparatus for transport properties, thermodynamic properties, phase equilibria, and dielectric properties. Specific capabilities are: Thermal conductivity apparatus, vibrating wire viscometer, dual-sinker densimeter, high-temperature vibrating tube densimeter, dynamic phase equilibria apparatus, apparatus for dilute solutions, total-enthalpy flow calorimeter. Benchmark measurements were made (no data given) on pure and mixed alternative refrigerants and their mixtures with lubricants, and other fluids.

  12. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    Energy Technology Data Exchange (ETDEWEB)

    Almstroem, H.; Sundel, T. [National Defence Research Establishment, Stockholm (Sweden); Frid, W.; Engelbrektson, A.

    1998-01-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion at the rigid wall is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied, and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to about 40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (author)

  13. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    Energy Technology Data Exchange (ETDEWEB)

    Almstroem, H.; Sundel, T. (Nat. Defence Res. Establ., Tumba (Sweden)); Frid, W. (Swedish Nuclear Power Inspectorate, SE-10658, Stockholm (Sweden)); Engelbrektson, A. (VBB/SWECO, Box 34044, SE-10026, Stockholm (Sweden))

    1999-05-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion, at the rigid wall, is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to [approx]40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (orig.) 5 refs.

  14. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    International Nuclear Information System (INIS)

    Almstroem, H.; Sundel, T.; Frid, W.; Engelbrektson, A.

    1999-01-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion, at the rigid wall, is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to ∼40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (orig.)

  15. Assessing medical professionalism: A systematic review of instruments and their measurement properties

    Science.gov (United States)

    Li, Honghe; Liu, Yang; Wen, Deliang

    2017-01-01

    Background Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments’ measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. Methods A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990–2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument’s usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee’s criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. Results After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar’s instrument for nursing students, Nurse Practitioners’ Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Conclusion Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing

  16. Inflammatory bowel disease-specific health-related quality of life instruments: a systematic review of measurement properties.

    Science.gov (United States)

    Chen, Xin-Lin; Zhong, Liang-Huan; Wen, Yi; Liu, Tian-Wen; Li, Xiao-Ying; Hou, Zheng-Kun; Hu, Yue; Mo, Chuan-Wei; Liu, Feng-Bin

    2017-09-15

    This review aims to critically appraise and compare the measurement properties of inflammatory bowel disease (IBD)-specific health-related quality of life instruments. Medline, EMBASE and ISI Web of Knowledge were searched from their inception to May 2016. IBD-specific instruments for patients with Crohn's disease, ulcerative colitis or IBD were enrolled. The basic characteristics and domains of the instruments were collected. The methodological quality of measurement properties and measurement properties of the instruments were assessed. Fifteen IBD-specific instruments were included, which included twelve instruments for adult IBD patients and three for paediatric IBD patients. All of the instruments were developed in North American and European countries. The following common domains were identified: IBD-related symptoms, physical, emotional and social domain. The methodological quality was satisfactory for content validity; fair in internal consistency, reliability, structural validity, hypotheses testing and criterion validity; and poor in measurement error, cross-cultural validity and responsiveness. For adult IBD patients, the IBDQ-32 and its short version (SIBDQ) had good measurement properties and were the most widely used worldwide. For paediatric IBD patients, the IMPACT-III had good measurement properties and had more translated versions. Most methodological quality should be promoted, especially measurement error, cross-cultural validity and responsiveness. The IBDQ-32 was the most widely used instrument with good reliability and validity, followed by the SIBDQ and IMPACT-III. Further validation studies are necessary to support the use of other instruments.

  17. Hysteresis phenomena in hydraulic measurement

    International Nuclear Information System (INIS)

    Ran, H J; Farhat, M; Luo, X W; Chen, Y L; Xu, H Y

    2012-01-01

    Hysteresis phenomena demonstrate the lag between the generation and the removal of some physical phenomena. This paper studies the hysteresis phenomena of the head-drop in a scaled model pump turbine using experiment test and CFD methods. These lag is induced by complicated flow patterns, which influenced the reliability of rotating machine. Keeping the same measurement procedure is concluded for the hydraulic machine measurement.

  18. Pump instability phenomena generated by fluid forces

    Science.gov (United States)

    Gopalakrishnan, S.

    1985-01-01

    Rotor dynamic behavior of high energy centrifugal pumps is significantly affected by two types of fluid forces; one due to the hydraulic interaction of the impeller with the surrounding volute or diffuser and the other due to the effect of the wear rings. The available data on these forces is first reviewed. A simple one degree-of-freedom system containing these forces is analytically solved to exhibit the rotor dynamic effects. To illustrate the relative magnitude of these phenomena, an example of a multistage boiler feed pump is worked out. It is shown that the wear ring effects tend to suppress critical speed and postpone instability onset. But the volute-impeller forces tend to lower the critical speed and the instability onset speed. However, for typical boiler feed pumps under normal running clearances, the wear ring effects are much more significant than the destabilizing hydraulic interaction effects.

  19. Design of instantaneous liquid film thickness measurement system for conductive or non-conductive fluid with high viscosity

    Directory of Open Access Journals (Sweden)

    Yongxin Yu

    2017-06-01

    Full Text Available In the paper, a new capacitive sensor with a dielectric film coating was designed to measure the thickness of the liquid film on a flat surface. The measured medium can be conductive or non-conductive fluid with high viscosity such as silicone oil, syrup, CMC solution and melt. With the dielectric film coating, the defects caused by the humidity in a capacitor can be avoided completely. With a excitation frequency 0-20kHz, the static permittivity of capacitive sensor is obtained and stable when small thicknesses are monitored within the frequency of 0-3kHz. Based on the measurement principle, an experimental system was designed and verified including calibration and actual measurement for different liquid film thickness. Experimental results showed that the sensitivity, the resolution, repeatability and linear range of the capacitive sensor are satisfied to the liquid film thickness measurement. Finally, the capacitive measuring system was successfully applied to the water, silicone oil and syrup film thickness measurement.

  20. Diabetes-related emotional distress instruments: a systematic review of measurement properties.

    Science.gov (United States)

    Lee, Jiyeon; Lee, Eun-Hyun; Kim, Chun-Ja; Moon, Seung Hei

    2015-12-01

    The objectives of this study were to identify all available diabetes-related emotional distress instruments and evaluate the evidence regarding their measurement properties to help in the selection of the most appropriate instrument for use in practice and research. A systematic literature search was performed. PubMed, Embase, CINAHL, and PsycINFO were searched systematically for articles on diabetes-related emotional distress instruments. The Consensus-based Standards for the Selection of Health Measurement Instruments checklist was used to evaluate the methodological quality of the identified studies. The quality of results with respect to the measurement properties of each study was evaluated using Terwee's quality criteria. An ancillary meta-analysis was performed. Of the 2345 articles yielded by the search, 19 full-text articles evaluating 6 diabetes-related emotional distress instruments were included in this study. No instrument demonstrated evidence for all measurement properties. The Problem Areas in Diabetes scale (PAID) was the most frequently studied and the best validated of the instruments. Pooled summary estimates of the correlation coefficient between the PAID and serum glycated hemoglobin revealed a positive but weak correlation. No diabetes-related emotional distress instrument demonstrated evidence for all measurement properties. No instrument was better than another, although the PAID was the best validated and is thus recommended for use. Further psychometric studies of the diabetes-related emotional distress instruments with rigorous methodologies are required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Field instrumentation for hydrofracturing stress measurements

    International Nuclear Information System (INIS)

    Bjarnason, Bjarni; Torikka, Arne.

    1989-08-01

    A recently developed system for rock stress measurements by the hydraulic fracturing method is documented in detail. The new equipment is intended for measurement in vertical or nearvertical boreholes, down to a maximum depth of 1000 m. The minimum borehole, diameter required is 56 mm. Downhole instrumentation comprises a straddle packer assembly for borehole fracturing, equipment for determination of fracture orientations and a pressure transducer. The downhole tools are operated by means of a multihose system, containing high pressure hydraulic tubings, signal cable and carrying wire into one hose unit. The surface components of the equipment include a system for generation and control of water pressures up to approximately 75 MPa, an hydraulically operated drum for the multihose and a data acquisition system. All surface instrumentation is permanently mounted on a truck, which also serves as power source for the instrumentation. In addition to the description of instrumentation, the theoretical fundament and the testing procedures associated with the hydraulic fracturing method are briefly outlined

  2. Measurement of Henry's Law Constants Using Internal Standards: A Quantitative GC Experiment for the Instrumental Analysis or Environmental Chemistry Laboratory

    Science.gov (United States)

    Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.

    2008-01-01

    An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…

  3. Instruments for measuring mental health recovery: a systematic review.

    Science.gov (United States)

    Sklar, Marisa; Groessl, Erik J; O'Connell, Maria; Davidson, Larry; Aarons, Gregory A

    2013-12-01

    Persons in recovery, providers, and policymakers alike are advocating for recovery-oriented mental health care, with the promotion of recovery becoming a prominent feature of mental health policy in the United States and internationally. One step toward creating a recovery-oriented system of care is to use recovery-oriented outcome measures. Numerous instruments have been developed to assess progress towards mental health recovery. This review identifies instruments of mental health recovery and evaluates the appropriateness of their use including their psychometric properties, ease of administration, and service-user involvement in their development. A literature search using the Medline and Psych-INFO databases was conducted, identifying 21 instruments for potential inclusion in this review, of which thirteen met inclusion criteria. Results suggest only three instruments (25%) have had their psychometric properties assessed in three or more unique samples of participants. Ease of administration varied between instruments, and for the majority of instruments, development included service user involvement. This review updates and expands previous reviews of instruments to assess mental health recovery. As mental health care continues to transform to a recovery-oriented model of service delivery, this review may facilitate selection of appropriate assessments of mental health recovery for systems to use in evaluating and improving the care they provide. © 2013.

  4. Model SH intelligent instrument for thickness measuring

    International Nuclear Information System (INIS)

    Liu Juntao; Jia Weizhuang; Zhao Yunlong

    1995-01-01

    The authors introduce Model SH Intelligent Instrument for thickness measuring by using principle of beta back-scattering and its application range, features, principle of operation, system design, calibration and specifications

  5. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  6. FY 2000 Annual Report for EMSP Project No.70108 - Effects of Fluid Distribution on Measured Geophysical Properties for Partially Saturated, Shallow Subsurface Conditions

    International Nuclear Information System (INIS)

    Berge, P.A.; Bonner, B.P.; Roberts, J.J.; Wildenschild, D.; Aracne-Ruddle, C.M.; Berryman, J.G.; Bertete-Aguirre, H.; Boro, C.O.; Carlberg, E.D.

    2000-01-01

    Our goal is to improve geophysical imaging of the vadose zone. We will achieve this goal by providing new methods to improve interpretation of field data. The purpose of this EMSP project is to develop relationships between laboratory measured geophysical properties and porosity, saturation, and fluid distribution, for partially saturated soils. Algorithms for relationships between soil composition, saturation, and geophysical measurements will provide new methods to interpret geophysical field data collected in the vadose zone at sites such as Hanford, WA. This report summarizes work after 10 months of a 3-year project. We have modified a laboratory ultrasonics apparatus developed in a previous EMSP project (No.55411) so that we can make velocity measurements for partially-saturated samples rather than fully-saturated or dry samples. We are testing the measurement apparatus using standard laboratory sand samples such as Ottawa sand samples. Preliminary results indicate that we can measure both compressional and shear velocities in these sand samples. We have received Hanford soil samples (sands from split-spoon cores from an uncontaminated site) and expect to make ultrasonic measurements on them also. We have used the LLNL x-ray facility to perform x-ray computed tomography (XCT) imaging for several partially-saturated Ottawa sand and Lincoln sand samples, and have also used the DOE Advance Photon Source at Argonne National Laboratory to make higher-resolution images of some sand samples. Preliminary results indicate that we can image amount and distribution of fluids in homogeneous sand samples. Continuing work from the previous EMSP project, we are testing a new data analysis method for seismic data that is expected to improve interpretation of seismic data from the vadose zone by showing how partial saturation affects seismic parameters. Our results suggest that the planned approach for this research is appropriate, that microstructure is an important factor

  7. Measurement properties of outcome measures for vitiligo. A systematic review.

    Science.gov (United States)

    Vrijman, Charlotte; Linthorst Homan, May W; Limpens, Jacqueline; van der Veen, Wietze; Wolkerstorfer, Albert; Terwee, Caroline B; Spuls, Phyllis I

    2012-11-01

    OBJECTIVE To summarize and critically appraise the evidence on the measurement properties of clinician-, patient-, and observer-reported outcomes, measuring any construct of interest in patients with all types of vitiligo. DATA SOURCES Electronic databases including PubMed (1948 to July 2011), OVID EMBASE (1980 to July 2011), and CINAHL (EBSCOhost) (1982 to July 2011) were searched. STUDY SELECTION Two authors independently screened all records for eligibility. For inclusion, the study population had to include patients with vitiligo, for which outcome measures were developed or evaluated on their measurement properties. The initial search retrieved 1249 records, of which 14 articles met the inclusion criteria. DATA EXTRACTION Characteristics of the included instruments, study population, and results of the measurement properties were extracted. The Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) 4-point checklist, combined with quality criteria for measurement properties, was used to calculate the overall level of evidence per measurement property of each instrument. Independent extraction and assessment was performed by 2 authors. DATA SYNTHESIS Eleven different measurement instruments were identified. Strong evidence was found for a positive internal consistency of the Dermatology Life Quality Index. For other instruments, the evidence of measurement properties was limited or unknown. CONCLUSIONS Recommendations on the use of specific outcome measures for vitiligo should be formulated with caution because current evidence is insufficient owing to a low number of studies with poor methodological quality and unclear clinical relevance. To recommend outcome measures for vitiligo, further research on measurement properties of clinical relevant outcome measures for vitiligo according to COSMIN quality criteria is needed.

  8. Measurement properties of instruments assessing permanent functional impairment of the spine: a systematic review protocol.

    Science.gov (United States)

    Goes, Suelen Meira; Trask, Catherine M; Boden, Catherine; Bath, Brenna; Ribeiro, Daniel Cury; Hendrick, Paul; Clay, Lynne; Zeng, Xiaoke; Milosavljevic, Stephan

    2018-01-27

    Permanent functional impairment (PFI) of the spine is a rating system used by compensation authorities, such as workers compensation boards, to establish an appropriate level of financial compensation for persistent loss of function. Determination of PFI of the spine is commonly based on the assessment of spinal movement combined with other measures of physical and functional impairments; however, the reliability and validity of the measurement instruments used for these evaluations have yet to be established. The aim of this study is to systematically review and synthesise the literature concerning measurement properties of the various and different instruments used for assessing PFI of the spine. Three conceptual groups of terms (1) PFI, (2) spinal disorder and (3) measurement properties will be combined to search Medline, EMBASE, CINAHL, Web of Science, Scopus, PEDro, OTSeeker and Health and Safety Science Abstracts. We will examine peer-reviewed, full-text articles over the full available date range. Two reviewers will independently screen citations (title, abstract and full text) and perform data extraction. Included studies will be appraised as to their methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments criteria. Findings will be summarised and presented descriptively, with meta-analysis pursued as appropriate. This review will summarise the current level of evidence of measurement properties of instruments used for assessing PFI of the spine. Findings of this review may be applicable to clinicians, policy-makers, workers' compensation boards, other insurers and health and safety organisations. The findings will likely provide a foundation and direction for future research priorities for assessing spinal PFI. CRD42017060390. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  9. Apparatus for measuring fluid flow

    Science.gov (United States)

    Smith, J.E.; Thomas, D.G.

    Flow measuring apparatus includes a support loop having strain gages mounted thereon and a drag means which is attached to one end of the support loop and which bends the sides of the support loop and induces strains in the strain gages when a flow stream impacts thereon.

  10. Instrument for measuring fuel cladding strain

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1976-01-01

    Development work to provide instrumentation for the continuous measurement of strain of material specimens such as nuclear fuel cladding has shown that a microwave sensor and associated instrumentation hold promise. The cylindrical sensor body enclosing the specimen results in a coaxial resonator absorbing microwave energy at frequencies dependent upon the diameter of the specimen. Diametral changes of a microinch can be resolved with use of the instrumentation. Very reasonable values of elastic strain were measured at 75 0 F and 1000 0 F for an internally pressurized 20 percent C.W. 316 stainless steel specimen simulating nuclear fuel cladding. The instrument also indicated the creep strain of the same specimen pressurized at 6500 psi and at a temperature of 1000 0 F for a period of 700 hours. Although the indicated strain appears greater than actual, the sensor/specimen unit experienced considerable oxidation even though an inert gas purge persisted throughout the test duration. By monitoring at least two modes of resonance, the measured strain was shown to be nearly independent of sensor temperature. To prevent oxidation, a second test was performed in which the specimen/sensor units were contained in an evacuated enclosure. The strain of the two prepressurized specimens as indicated by the microwave instrumentation agreed very closely with pre- and post-test measurements obtained with use of a laser interferometer

  11. Apparatus and method for the measurement of neutron moderating or absorbing properties of objects

    International Nuclear Information System (INIS)

    Untermyer, S.I.

    1981-01-01

    An apparatus and method for measuring the neutron moderating or absorbing properties of objects or materials is disclosed in which a fast neutron source cooperates with a neutron absorbing material which reduces the energy of the fast neutrons by inelastic scattering so that they can be readily thermalized by a moderator. A thermal neutron detector is disposed adjacent the material and serves to detect thermal neutrons emitted by a moderator placed to receive and thermalize the reduced energy neutrons. A material whose absorption is to be measured is placed between a moderator and the detector

  12. Status of thermophysical properties data for pure fluids and mixtures of cryogenic interest

    International Nuclear Information System (INIS)

    Haynes, W.M.; Hiza, M.J.; Kidney, A.J.; Olien, N.A.

    1984-01-01

    This chapter discusses the importance, availability, and deficiencies of the existing data bases for the thermophysical properties of cryogenic fluids, including mixtures, considering both scientific and engineering interests. The following types of phase equilibria are emphasized: liquid-vapor, solid-vapor, liquid-liquid (or liquid-liquid-vapor), and solid-liquid (or solid-liquid-vapor). The available thermophysical properties data for both pure fluids and mixtures are summarized. Specific recommendations are made for future experimental measurements. It is predicted that the major thrust of future studies of cryogenic fluids will involve mixtures. The fluids considered include those involved in cryogenic processing with melting temperatures below ambient

  13. Measurement control program for NDA instruments

    International Nuclear Information System (INIS)

    Hsue, S.T.; Marks, T.

    1983-01-01

    Measurement control checks for nondestructive assay instruments have been a constant and continuing concern at Los Alamos National Laboratory. This paper summarizes the evolution of the measurement control checks in the various high-resolution gamma systems we have developed. In-plant experiences with these systems and checks will be discussed. Based on these experiences, a set of measurement control checks is recommended for high-resolution gamma-ray systems

  14. Identification of key outcome measures when using the instrumented timed up and go and/or posturography for fall screening.

    Science.gov (United States)

    Sample, Renee Beach; Kinney, Allison L; Jackson, Kurt; Diestelkamp, Wiebke; Bigelow, Kimberly Edginton

    2017-09-01

    The Timed Up and Go (TUG) has been commonly used for fall risk assessment. The instrumented Timed Up and Go (iTUG) adds wearable sensors to capture sub-movements and may be more sensitive. Posturography assessments have also been used for determining fall risk. This study used stepwise logistic regression models to identify key outcome measures for the iTUG and posturography protocols. The effectiveness of the models containing these measures in differentiating fallers from non-fallers were then compared for each: iTUG total time duration only, iTUG, posturography, and combined iTUG and posturography assessments. One hundred and fifty older adults participated in this study. The iTUG measures were calculated utilizing APDM Inc.'s Mobility Lab software. Traditional and non-linear posturography measures were calculated from center of pressure during quiet-standing. The key outcome measures incorporated in the iTUG assessment model (sit-to-stand lean angle and height) resulted in a model sensitivity of 48.1% and max re-scaled R 2 value of 0.19. This was a higher sensitivity, indicating better differentiation, compared to the model only including total time duration (outcome of the traditional TUG), which had a sensitivity of 18.2%. When the key outcome measures of the iTUG and the posturography assessments were combined into a single model, the sensitivity was approximately the same as the iTUG model alone. Overall the findings of this study support that the iTUG demonstrates greater sensitivity than the total time duration, but that carrying out both iTUG and posturography does not greatly improve sensitivity when used as a fall risk screening tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Measurement of two phase flow properties using the nuclear reactor instruments

    International Nuclear Information System (INIS)

    Albrecht, R.W.; Washington Univ., Seattle; Crowe, R.D.; Dailey, D.J.; Kosaly, G.; Damborg, M.J.

    1982-01-01

    A procedure is introduced for characterizing one dimensional, two phase flow in terms of three properties; propagation, structure, and dynamics. It is shown that all of these properties can be measured by analyzing the response of the reactor neutron field to a two phase flow perturbation. Therefore, a nuclear reactor can be regarded as a two phase flow instrument. (author)

  16. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

    Science.gov (United States)

    Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

  17. Electronic instrumentation system for pulsed neutron measurements

    International Nuclear Information System (INIS)

    Burda, J.; Igielski, A.; Kowalik, W.

    1982-01-01

    An essential point of pulsed neutron measurement of thermal neutron parameters for different materials is the registration of the thermal neutron die-away curve after a fast neutron bursts have been injected into the system. An electronic instrumentation system which is successfully applied for pulsed neutron measurements is presented. An important part of the system is the control unit which has been designed and built in the Laboratory of Neutron Parameters of Materials. (author)

  18. The Complex Trauma Questionnaire (ComplexTQ:Development and preliminary psychometric properties of an instrument for measuring early relational trauma

    Directory of Open Access Journals (Sweden)

    Carola eMaggiora Vergano

    2015-09-01

    Full Text Available Research on the etiology of adult psychopathology and its relationship with childhood trauma has focused primarily on specific forms of maltreatment. This study developed an instrument for the assessment of childhood and adolescence trauma that would aid in identifying the role of co-occurring childhood stressors and chronic adverse conditions. The Complex Trauma Questionnaire (ComplexTQ, in both clinician and self-report versions, is a measure for the assessment of multi-type maltreatment: physical, psychological, and sexual abuse; physical and emotional neglect as well as other traumatic experiences, such rejection, role reversal, witnessing domestic violence, separations, and losses. The four-point Likert scale allows to specifically indicate with which caregiver the traumatic experience has occurred. A total of 229 participants, a sample of 79 nonclinical and that of 150 high-risk and clinical participants, were assessed with the ComplexTQ clinician version applied to Adult Attachment Interview (AAI transcripts. Initial analyses indicate acceptable inter-rater reliability. A good fit to a 6-factor model regarding the experience with the mother and to a 5-factor model with the experience with the father was obtained; the internal consistency of factors derived was good. Convergent validity was provided with the AAI scales. ComplexTQ factors discriminated normative from high-risk and clinical samples. The findings suggest a promising, reliable, and valid measurement of early relational trauma that is reported; furthermore, it is easy to complete and is useful for both research and clinical practice.

  19. Computational transport phenomena for engineering analyses

    CERN Document Server

    Farmer, Richard C; Cheng, Gary C; Chen, Yen-Sen

    2009-01-01

    Computational Transport PhenomenaOverviewTransport PhenomenaAnalyzing Transport PhenomenaA Computational Tool: The CTP CodeVerification, Validation, and GeneralizationSummaryNomenclatureReferencesThe Equations of ChangeIntroductionDerivation of The Continuity EquationDerivation of The Species Continuity EquationDerivation of The Equation Of MotionDerivation of The General Energy EquationNon-Newtonian FluidsGeneral Property BalanceAnalytical and Approximate Solutions for the Equations of ChangeSummaryNomenclatureReferencesPhysical PropertiesOverviewReal-Fluid ThermodynamicsChemical Equilibrium

  20. Nuclear instrumentation for the industrial measuring systems

    International Nuclear Information System (INIS)

    Normand, S.

    2010-01-01

    This work deals with nuclear instrumentation and its application to industry, power plant fuel reprocessing plant and finally with homeland security. The first part concerns the reactor instrumentation, in-core and ex-core measurement system. Ionization Uranium fission chamber will be introduced with their acquisition system especially Campbell mode system. Some progress have been done on regarding sensors failure foresee. The second part of this work deals with reprocessing plant and associated instrumentation for nuclear waste management. Proportional counters techniques will be discussed, especially Helium-3 counter, and new development on electronic concept for reprocessing nuclear waste plant (one electronic for multipurpose acquisition system). For nuclear safety and security for human and homeland will be introduce. First we will explain a new particular approach on operational dosimetric measurement and secondly, we will show new kind of organic scintillator material and associated electronics. Signal treatment with real time treatment is embedded, in order to make neutron gamma discrimination possible even in solid organic scintillator. Finally, the conclusion will point out future, with most trends in research and development on nuclear instrumentation for next years. (author) [fr

  1. Method and device for measuring fluid flow

    International Nuclear Information System (INIS)

    Atherton, R.; Marinkovich, P.S.; Spadaro, P.R.; Stout, J.W.

    1976-01-01

    The invention is a fluid flow measuring device for determining the coolant flow at the entrance to a specific nuclear reactor fuel region. The device comprises a plurality of venturis having the upstream inlet and throat pressure of each respectively manifolded together to provide one static pressure signal for each region monitored. The device provides accurate flow measurement with low pressure losses and uniform entrance and discharge flow distribution. 1 claim, 7 figures

  2. 77 FR 37409 - Request for Domains, Instruments, and Measures for Development of a Standardized Instrument for...

    Science.gov (United States)

    2012-06-21

    ... experience as well. On both issues, CMS is interested in instruments and items which can measure quality of... Measures for Development of a Standardized Instrument for Use in Public Reporting of Enrollee Satisfaction..., communication, coordination of care, customer service), instruments, and measures for measuring the level of...

  3. Measurement properties of instruments that assess participation in young people with autism spectrum disorder: a systematic review.

    Science.gov (United States)

    Lami, Francesca; Egberts, Kristine; Ure, Alexandra; Conroy, Rowena; Williams, Katrina

    2018-03-01

    To systematically review the measurement properties of instruments assessing participation in young people with autism spectrum disorder (ASD). A search was performed in MEDLINE, PsycINFO, and PubMed combining three constructs ('ASD', 'test of participation', 'measurement properties'). Results were restricted to articles including people aged 6 to 29 years. The 2539 identified articles were independently screened by two reviewers. For the included articles, data were extracted using standard forms and their risk of bias was assessed. Nine studies (8 cross-sectional) met the inclusion criteria, providing information on seven different instruments. The total sample included 634 participants, with sex available for 600 (males=494; females=106) and age available for 570, with mean age for these participants 140.58 months (SD=9.11; range=36-624). Included instruments were the school function assessment, vocational index, children's assessment of participation and enjoyment/preferences for activities of children, experience sampling method, Pediatric Evaluation of Disability Inventory, Computer Adaptive Test, adolescent and young adult activity card sort, and Patient-Reported Outcomes Measurement Information System parent-proxy peer relationships. Seven studies assessed reliability and validity; good properties were reported for half of the instruments considered. Most studies (n=6) had high risk of bias. Overall the quality of the evidence for each tool was limited. Validation of these instruments, or others that comprehensively assess participation, is needed. Future studies should follow recommended methodological standards. Seven instruments have been used to assess participation in young people with autism. One instrument, with excellent measurement properties in one study, does not comprehensively assess participation. Studies of three instruments that incorporate a more comprehensive assessment of participation have methodological limitations. Overall, limited

  4. Instruments to assess patients with rotator cuff pathology: a systematic review of measurement properties.

    Science.gov (United States)

    Longo, Umile Giuseppe; Saris, Daniël; Poolman, Rudolf W; Berton, Alessandra; Denaro, Vincenzo

    2012-10-01

    The aims of this study were to obtain an overview of the methodological quality of studies on the measurement properties of rotator cuff questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. A systematic review of published studies on the measurement properties of rotator cuff questionnaires was performed. Two investigators independently rated the quality of the studies using the Consensus-based Standards for the selection of health Measurement Instruments checklist. This checklist was developed in an international Delphi consensus study. Sixteen studies were included, in which two measurement instruments were evaluated, namely the Western Ontario Rotator Cuff Index and the Rotator Cuff Quality-of-Life Measure. The methodological quality of the included studies was adequate on some properties (construct validity, reliability, responsiveness, internal consistency, and translation) but need to be improved on other aspects. The most important methodological aspects that need to be developed are as follows: measurement error, content validity, structural validity, cross-cultural validity, criterion validity, and interpretability. Considering the importance of adequate measurement properties, it is concluded that, in the field of rotator cuff pathology, there is room for improvement in the methodological quality of studies measurement properties. II.

  5. Application of Fermat's Principle to Calculation of the Errors of Acoustic Flow-Rate Measurements for a Three-Dimensional Fluid Flow or Gas

    Science.gov (United States)

    Petrov, A. G.; Shkundin, S. Z.

    2018-01-01

    Fermat's variational principle is used for derivation of the formula for the time of propagation of a sonic signal between two set points A and B in a steady three-dimensional flow of a fluid or gas. It is shown that the fluid flow changes the time of signal reception by a value proportional to the flow rate independently of the velocity profile. The time difference in the reception of the signals from point B to point A and vice versa is proportional with a high accuracy to the flow rate. It is shown that the relative error of the formula does not exceed the square of the largest Mach number. This makes it possible to measure the flow rate of a fluid or gas with an arbitrary steady subsonic velocity field.

  6. An Undergraduate Experiment for the Measurement of the Speed of Sound in Air: Phenomena and Discussion

    Science.gov (United States)

    Yang, Hujiang; Zhao, Xiaohong; Wang, Xin; Xiao, Jinghua

    2012-01-01

    In this paper, we present and discuss some phenomena in an undergraduate experiment for the measurement of the speed of sound in air. A square wave distorts when connected to a piezoelectric transducer. Moreover, the amplitude of the receiving signal varies with the driving frequency. Comparing with the Gibbs phenomenon, these phenomena can be…

  7. Evaluation of the SCA instrument for measuring patient satisfaction with cancer care administered via paper or via the Internet.

    Science.gov (United States)

    Kamo, N; Dandapani, S V; Miksad, R A; Houlihan, M J; Kaplan, I; Regan, M; Greenfield, T K; Sanda, M G

    2011-03-01

    Patients' perspectives provide valuable information on quality of care. This study evaluates the feasibility and validity of Internet administration of Service Satisfaction Scale for Cancer Care (SCA) to assess patient satisfaction with outcome, practitioner manner/skill, information, and waiting/access. Primary data collected from November 2007 to April 2008. Patients receiving cancer care within 1 year were recruited from oncology, surgery, and radiation clinics at a tertiary care hospital. An Internet-based version of the 16-item SCA was developed. Participants were randomised to Internet SCA followed by paper SCA 2 weeks later or vice versa. Seven-point Likert scale responses were converted to a 0-100 scale (minimum-maximum satisfaction). Response distribution, Cronbach's alpha, and test-retest correlations were calculated. Among 122 consenting participants, 78 responded to initial SCA. Mean satisfaction scores for paper/Internet were 91/90 (outcome), 95/94 (practitioner manner/skill), 89/90 (information), and 86/86 (waiting/access). Response rate and item missingness were similar for Internet and paper. Except for practitioner manner/skill, test-retest correlations were robust r = 0.77 (outcome), 0.74 (information), and 0.75 (waiting/access) (all P measurement of cancer care satisfaction for a wide range of cancer diagnoses, treatment modalities, and clinic settings.

  8. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  9. Instrument for measuring moisture in wood chips

    Energy Technology Data Exchange (ETDEWEB)

    Werme, L

    1980-06-01

    A method to determine the moisture content in wood chips, in batch and on-line, has been investigated. The method can be used for frozen and non frozen chips. Samples of wood chips are thawn and dryed with microwaves. During the drying the sample is weighed continously and the rate of drying is measured. The sample is dried t 10 percent moisture content. The result is extrapolated to the drying rate zero. The acccuracy at the method is 1.6 to 1.7 percent for both frozen and non frozen chips. The accuracy of the method is considered acceptable, but sofisticated sampling equipment is necessary. This makes the method too complex to make the instrument marketable.

  10. The laser, measuring instrument for plasmas

    International Nuclear Information System (INIS)

    Anderegg, F.; Behn, R.; Paris, P.J.; Salito, S.A.; Siegrist, M.R.; Weisen, H.

    1988-06-01

    There are several different and in general complementary methods for the investigation of plasmas. All of them have different characteristics and properties covering a large spectrum of physical measuring techniques. Electromagnetic waves serving as 'thermometers' permit to detect the global behaviour of the plasma as well as that of the particles composing it. One of the advantages of these introspective methods is that it brings information on temporary and local conditions of the domain being interrogated. With the development of micro-wave sources and lasers after the war the principal tools of this type of plasma diagnostics are now available. In this paper the emphasis is on the lasers which are different according to the type of measurement. Their versatility in measuring plasma parameters is largely acknowledged. We illustrate the potential of measuring methods by lasers by means of the research work done at two experimental installations of CRPP. (author) 21 figs., 8 refs

  11. Comparison of nanoparticle measurement instruments for occupational health applications

    International Nuclear Information System (INIS)

    Leskinen, J.; Joutsensaari, J.; Lyyränen, J.; Koivisto, J.; Ruusunen, J.; Järvelä, M.; Tuomi, T.; Hämeri, K.; Auvinen, A.; Jokiniemi, J.

    2012-01-01

    Nanoparticles are used in many applications because of their novel properties compared to bulk material. A growing number of employees are working with nanomaterials and their exposure to nanoparticles trough inhalation must be evaluated and monitored continuously. However, there is an ongoing debate in the scientific literature about what are the relevant parameters to measure to evaluate exposure to level. In this study, three types of nanoparticles (ammonium sulphate, synthesised TiO 2 agglomerates and aerosolised TiO 2 powder, modes in a range of 30–140 nm mobility size) were measured with commonly used aerosol measurement instruments: scanning and fast mobility particle sizers (SMPS, FMPS), electrical low pressure impactor (ELPI), condensation particle counter (CPC) together with nanoparticle surface area monitor (NSAM) to achieve information about the interrelations of the outputs of the instruments. In addition, the ease of use of these instruments was evaluated. Differences between the results of different instruments can mainly be attributed to the nature of test particles. For spherical ammonium sulphate nanoparticles, the data from the instruments were in good agreement while larger differences were observed for particles with more complex morphology, the TiO 2 agglomerates and powder. For instance, the FMPS showed a smaller particle size, a higher number concentration and a narrower size distribution compared with the SMPS for TiO 2 particles. Thus, the type of the nanoparticle was observed to influence the data obtained from these different instruments. Therefore, care and expertise are essential when interpreting results from aerosol measurement instruments to estimate nanoparticle concentrations and properties.

  12. Ionizing radiation measurements using low cost instruments for teaching in college or high-school in Brazil

    Science.gov (United States)

    Silva, M. C.; Vilela, D. C.; Migoto, V. G.; Gomes, M. P.; Martin, I. M.; Germano, J. S. E.

    2017-11-01

    Ionizing radiation one of modern physics experimental teaching in colleges and high school can be easily implemented today due to low coasts of detectors and also electronic circuits and data acquisition interfaces. First it is interesting to show to young’s students what is ionizing radiation and from where they appears near ground level? How it is possible to measure these radiations and how to check intensities variation during day, night, dry and wet periods in the same school? For increasing interest and stimulation in others students how to proceed in making the graphics of the ionizing radiation and presenting him in real time using Web internet facilities? Many others facilities like calibration of the detector using low intensities radioactive ionizing radiation sources, make comparison of the measurements and discussions of the results should be possible between many groups of students from several schools in the region of Brazil. This paper presents the experimental procedures including detectors and associated electronic including data acquisition, graphics elaboration and Web internet procedures to discuss and exchanging data measurements from several schools.

  13. Measurement properties of instruments assessing permanent functional impairment of the spine: a systematic review protocol

    Science.gov (United States)

    Trask, Catherine M; Boden, Catherine; Bath, Brenna; Hendrick, Paul; Clay, Lynne; Zeng, Xiaoke; Milosavljevic, Stephan

    2018-01-01

    Introduction Permanent functional impairment (PFI) of the spine is a rating system used by compensation authorities, such as workers compensation boards, to establish an appropriate level of financial compensation for persistent loss of function. Determination of PFI of the spine is commonly based on the assessment of spinal movement combined with other measures of physical and functional impairments; however, the reliability and validity of the measurement instruments used for these evaluations have yet to be established. The aim of this study is to systematically review and synthesise the literature concerning measurement properties of the various and different instruments used for assessing PFI of the spine. Methods Three conceptual groups of terms (1) PFI, (2) spinal disorder and (3) measurement properties will be combined to search Medline, EMBASE, CINAHL, Web of Science, Scopus, PEDro, OTSeeker and Health and Safety Science Abstracts. We will examine peer-reviewed, full-text articles over the full available date range. Two reviewers will independently screen citations (title, abstract and full text) and perform data extraction. Included studies will be appraised as to their methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments criteria. Findings will be summarised and presented descriptively, with meta-analysis pursued as appropriate. Ethics and dissemination This review will summarise the current level of evidence of measurement properties of instruments used for assessing PFI of the spine. Findings of this review may be applicable to clinicians, policy-makers, workers’ compensation boards, other insurers and health and safety organisations. The findings will likely provide a foundation and direction for future research priorities for assessing spinal PFI. PROSPERO registration number CRD42017060390. PMID:29374671

  14. Working fluid selection for organic Rankine cycles - Impact of uncertainty of fluid properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Andreasen, Jesper Graa; Liu, Wei

    2016-01-01

    of processmodels and constraints 2) selection of property models, i.e. Penge Robinson equation of state 3)screening of 1965 possible working fluid candidates including identification of optimal process parametersbased on Monte Carlo sampling 4) propagating uncertainty of fluid parameters to the ORC netpower output......This study presents a generic methodology to select working fluids for ORC (Organic Rankine Cycles)taking into account property uncertainties of the working fluids. A Monte Carlo procedure is described as a tool to propagate the influence of the input uncertainty of the fluid parameters on the ORC....... The net power outputs of all the feasible working fluids were ranked including their uncertainties. The method could propagate and quantify the input property uncertainty of the fluidproperty parameters to the ORC model, giving an additional dimension to the fluid selection process. In the given analysis...

  15. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders.

    Science.gov (United States)

    Abma, Femke I; van der Klink, Jac J L; Terwee, Caroline B; Amick, Benjamin C; Bültmann, Ute

    2012-01-01

    During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in occupational health practice and research, the measurement properties (eg, reliability, validity, responsiveness) must be evaluated. The objective of this study is to appraise critically and compare the measurement properties of self-reported health-related work-functioning instruments among workers with CMD. A systematic review was performed searching three electronic databases. Papers were included that: (i) mainly focused on the development and/or evaluation of the measurement properties of a self-reported health-related work-functioning instrument; (ii) were conducted in a CMD population; and (iii) were fulltext original papers. Quality appraisal was performed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. Five papers evaluating measurement properties of five self-reported health-related work-functioning instruments in CMD populations were included. There is little evidence available for the measurement properties of the identified instruments in this population, mainly due to low methodological quality of the included studies. The available evidence on measurement properties is based on studies of poor-to-fair methodological quality. Information on a number of measurement properties, such as measurement error, content validity, and cross-cultural validity is still lacking. Therefore, no evidence-based decisions and recommendations can be made for the use of health-related work functioning instruments. Studies of high methodological quality are needed to properly assess the existing instruments' measurement properties.

  16. Systematic review of studies on measurement properties of instruments for adults published in the American Journal of Occupational Therapy, 2009-2013.

    Science.gov (United States)

    Yuen, Hon K; Austin, Sarah L

    2014-01-01

    We describe the methodological quality of recent studies on instrument development and testing published in the American Journal of Occupational Therapy (AJOT). We conducted a systematic review using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist to appraise 48 articles on measurement properties of assessments for adults published in AJOT between 2009 and 2013. Most studies had adequate methodological quality in design and statistical analysis. Common methodological limitations included that methods used to examine internal consistency were not consistently linked to the theoretical constructs underpinning assessments; participants in some test-retest reliability studies were not stable during the interim period; and in several studies of reliability and convergent validity, sample sizes were inadequate. AJOT's dissemination of psychometric research evidence has made important contributions to moving the profession toward the American Occupational Therapy Association's Centennial Vision. This study's results provide a benchmark by which to evaluate future accomplishments. Copyright © 2014 by the American Occupational Therapy Association, Inc.

  17. Transport phenomena in Newtonian fluids a concise primer

    CERN Document Server

    Olsson, Per

    2013-01-01

    This short primer provides a concise and tutorial-style introduction to transport phenomena in Newtonian fluids , in particular the transport of mass, energy and momentum.  The reader will find detailed derivations of the transport equations for these phenomena, as well as selected analytical solutions to the transport equations in some simple geometries. After a brief introduction to the basic mathematics used in the text, Chapter 2, which deals with momentum transport, presents a derivation of the Navier-Stokes-Duhem equation describing the basic flow in a Newtonian fluid.  Also provided at

  18. SEARCHING FOR ELECTRICAL PROPERTIES, PHENOMENA AND MECHANISMS IN THE CONSTRUCTION AND FUNCTION OF CHROMOSOMES

    Directory of Open Access Journals (Sweden)

    Ivan Kanev

    2013-03-01

    Full Text Available Our studies reveal previously unidentified electrical properties of chromosomes: (1 chromosomes are amazingly similar in construction and function to electrical transformers; (2 chromosomes possess in their construction and function, components similar to those of electric generators, conductors, condensers, switches, and other components of electrical circuits; (3 chromosomes demonstrate in nano-scale level electromagnetic interactions, resonance, fusion and other phenomena similar to those described by equations in classical physics. These electrical properties and phenomena provide a possible explanation for unclear and poorly understood mechanisms in clinical genetics including: (a electrically based mechanisms responsible for breaks, translocations, fusions, and other chromosomal abnormalities associated with cancer, intellectual disability, infertility, pregnancy loss, Down syndrome, and other genetic disorders; (b electrically based mechanisms involved in crossing over, non-disjunction and other events during meiosis and mitosis; (c mechanisms demonstrating heterochromatin to be electrically active and genetically important.

  19. Working fluid selection for organic Rankine cycles - Impact of uncertainty of fluid properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Andreasen, Jesper Graa; Liu, Wei

    2016-01-01

    This study presents a generic methodology to select working fluids for ORC (Organic Rankine Cycles)taking into account property uncertainties of the working fluids. A Monte Carlo procedure is described as a tool to propagate the influence of the input uncertainty of the fluid parameters on the ORC...... modeloutput, and provides the 95%-confidence interval of the net power output with respect to the fluid property uncertainties. The methodology has been applied to a molecular design problem for an ORCusing a low-temperature heat source and consisted of the following four parts: 1) formulation...... of processmodels and constraints 2) selection of property models, i.e. Penge Robinson equation of state 3)screening of 1965 possible working fluid candidates including identification of optimal process parametersbased on Monte Carlo sampling 4) propagating uncertainty of fluid parameters to the ORC netpower output...

  20. ProRisk : risk analysis instrument : developed for William properties

    NARCIS (Netherlands)

    van Doorn, W.H.W.; Egeberg, Ingrid; Hendrickx, Kristoff; Kahramaner, Y.; Masseur, B.; Waijers, Koen; Weglicka, K.A.

    2005-01-01

    This report presents a Risk Analysis Instrument developed for William Properties. Based on the analysis, it appears that the practice of Risk Analysis exists within the organization, yet rather implicit. The Risk Analysis Instrument comes with a package of four components: an activity diagram, a

  1. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1991-07-01

    This research is concerned with the development of a quantitative scientific description of the thermodynamic and transport properties of supercritical and subcritical fluids and fluid mixtures. It is known that the thermophysical properties of fluids and fluid mixtures asymptotically close to the critical point satisfy scaling laws with universal critical exponents and universal scaling functions. However, the range of validity of these asymptotic scaling laws is quite small. As a consequence, the impact of the modern theory of critical phenomena on chemical engineering has been limited. On the other hand, an a priori estimate of the range of temperatures and densities, where critical fluctuations become significant, can be made on the basis of the so-called Ginzburg criterion. A recent analysis of this criterion suggests that this range is actually quite large and for a fluid like carbon dioxide can easily extend to 100 degrees or so above the critical temperature. Hence, the use of traditional engineering equations like cubic equations is not scientifically justified in a very wide range of temperatures and densities around the critical point. We have therefore embarked on a scientific approach to deal with the global effects of critical fluctuations on the thermophysical properties of fluids and fluid mixtures. For this purpose it is not sufficient to consider the asymptotic critical fluctuations but we need to deal also with the nonasymptotic critical fluctuations. The goal is to develop scientifically based questions that account for the crossover of the thermophysical properties from their asymptotic singular behavior in the near vicinity of the critical point to their regular behavior very far away from the critical point

  2. Robust Load Cell Cell for Discrete Contact Force Measurements of Sampling Systems and/or Instruments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Bear Engineering proposes to develop a simple, robust, extreme environment compatible, mechanical load cell to enable the control of contact forces for placement of...

  3. Determining Psychometric Properties of Iranian Active Aging Measurement Instrument

    Directory of Open Access Journals (Sweden)

    Elham Mohammadi

    2018-01-01

    Conclusion The 40-item AAMI consisting of six factors in the present study not only was shown to be reliable, valid and appropriate for Iranian older adults but was also confirmed to have both subjective and objective dimensions.

  4. Sex differences in patterns of genital sexual arousal: measurement artifacts or true phenomena?

    Science.gov (United States)

    Suschinsky, Kelly D; Lalumière, Martin L; Chivers, Meredith L

    2009-08-01

    Sex differences in patterns of sexual arousal have been reported recently. Men's genital arousal is typically more category-specific than women's, such that men experience their greatest genital arousal to stimuli depicting their preferred sex partners whereas women experience significant genital arousal to stimuli depicting both their preferred and non-preferred sex partners. In addition, men's genital and subjective sexual arousal patterns are more concordant than women's: The correlation between genital and subjective sexual arousal is much larger in men than in women. These sex differences could be due to low response-specificity in the measurement of genital arousal in women. The most commonly used measure of female sexual arousal, vaginal photoplethysmography, has not been fully validated and may not measure sexual arousal specifically. A total of 20 men and 20 women were presented with various sexual and non-sexual emotionally laden short film clips while their genital and subjective sexual arousal were measured. Results suggest that vaginal photoplethysmography is a measure of sexual arousal exclusively. Women's genital responses were highest during sexual stimuli and absent during all non-sexual stimuli. Sex differences in degree of category-specificity and concordance were replicated: Men's genital responses were more category-specific than women's and men's genital and subjective sexual arousal were more strongly correlated than women's. The results from the current study support the continued use of vaginal photoplethysmography in investigating sex differences in patterns of sexual arousal.

  5. Quality of Life among Turkish Immigrants in Sweden: a Study for Assessing the Measurement Properties of the World Health Organization’s Quality of Life 100 Instrument

    Directory of Open Access Journals (Sweden)

    Nazan Bilgel

    2011-04-01

    Full Text Available Many instruments have been developed to measure the multidimensional construct of quality of life. One of them has been developed by the World Health Organization (WHOQOL-100 and adapted into different languages and cultures around the world. The authors of this study wanted to assess the measurement properties of the Turkish version of WHOQOL-100, to find out the latent factors underlying quality of life, and to determine the direction and magnitude of the interdependent effects among these factors by using structural equation modeling (SEM. The measurement properties of the Turkish version of WHOQOL-100 scale were assessed on 520 voluntary participants who were immigrants in Stockholm/Sweden. SEM gave us one second-order factor QOL and the five correlated first-order factors labelled: physical, social relations, psychological, environment and independence. In the model for total participants, all the factor loadings were high (ranging from 0.60 to 0.92 except for “sexuality” which was 0.47, indicating a strong association between each of the latent factors and their respective items. In the models which were separately constructed regarding birthplace, the authors found a strong association between each of the latent factors and their respective items. The most substantial possible effect on QOL was psychological domain (0.93, which was larger than physical health (0.84, social relations (0.82, level of independence (0.91 and environment (0.73. The effect of psychological domain on the overall quality of life is greater than those of other domains.

  6. Applied measuring techniques for the investigation of time-dependent flow phenomena in centrifugal compressors

    International Nuclear Information System (INIS)

    Hass, U.; Haupt, U.; Jansen, M.; Kassens, K.; Knapp, P.; Rautenberg, M.

    1978-01-01

    During the past 10 years new measuring techniques have been developed for the experimental investigation of highly loaded centrifugal compressors. These measuring techniques take into account the time dependency of the fluctuating physical quantities such as pressure, temperature, and velocity. Some key points of these experimental techniques are shown and explained in this paper. An important basis for such measurements is the accurate dynamic calibration of the measuring apparatus. In addition, some problems involved analyzing measured signals are dealt with and pressure measurements and their interpretation are shown. Finally optical, acoustical and vibrational measuring procedures are described which are additionally used for the investigation of non-stationary flow phenomena. (orig.) [de

  7. Requirements for a quality measurement instrument for semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.; Krukkert, D.; Oude Luttighuis, P.; Hillegersberg van, J. van

    2010-01-01

    This study describes requirements for an instrument to measure the quality of semantic standards. A situational requirements engineering method was used, resulting in a goal-tree in which requirements are structured. This structure shows requirements related to the input of the instrument; stating

  8. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  9. Advances in fluid modeling and turbulence measurements

    International Nuclear Information System (INIS)

    Wada, Akira; Ninokata, Hisashi; Tanaka, Nobukazu

    2002-01-01

    The context of this book consists of four fields: Environmental Fluid Mechanics; Industrial Fluid Mechanics; Fundamentals of Fluid Mechanics; and Turbulence Measurements. Environmental Fluid Mechanics includes free surface flows in channels, rivers, seas, and estuaries. It also discusses wind engineering issues, ocean circulation model and dispersion problems in atmospheric, water and ground water environments. In Industrial Fluid Mechanics, fluid phenomena in energy exchanges, modeling of turbulent two- or multi-phase flows, swirling flows, flows in combustors, variable density flows and reacting flows, flows in turbo-machines, pumps and piping systems, and fluid-structure interaction are discussed. In Fundamentals of Fluid Mechanics, progress in modeling turbulent flows and heat/mass transfers, computational fluid dynamics/numerical techniques, parallel computing algorithms, applications of chaos/fractal theory in turbulence are reported. In Turbulence Measurements, experimental studies of turbulent flows, experimental and post-processing techniques, quantitative and qualitative flow visualization techniques are discussed. Separate abstracts were presented for 15 of the papers in this issue. The remaining 89 were considered outside the subject scope of INIS. (J.P.N.)

  10. Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments

    Directory of Open Access Journals (Sweden)

    Patrick DL

    2006-01-01

    Full Text Available Abstract Background Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability, the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs, i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist. Method An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1 a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2 an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will

  11. A novel application of Recursive Equation Method for determining thermodynamic properties of single phase fluids from density and speed-of-sound measurements

    International Nuclear Information System (INIS)

    Lago, S.; Giuliano Albo, P.A.

    2013-01-01

    Highlights: ► A novel method for calculating the isobaric specific heat capacity is presented. ► Heat capacity (C p ) was determined only by speed-of-sound and density measurements. ► (C p ) temperature dependence has been related to speed-of-sound by a new expression. ► Heat capacity for water, nonane, undecane, and rapeseed oil methyl ester are obtained. -- Abstract: The determination of thermal quantities from mechanical properties is still a challenge in the thermodynamic field. In this work, the authors suggest a preliminary numerical calculation which allows to determine the constant pressure specific heat capacity, starting from density and speed-of-sound experimental values, as input data. This method is a variant of the well characterized Recursive Equation Method (REM) [1] and permits to develop empirical equations of state for single phase fluids. In particular, the isobaric specific heat capacity has been obtained, in a wide range of temperatures and pressures, for pure water, n-nonane, n-undecane, and rapeseed oil methyl ester. The results have been compared with those available in the literature, when it was possible. Moreover, the typical uncertainty of heat capacity has been estimated to be in the order of 1.5%; however it has been shown that it can be improved when proper distributions of the experimental points are available

  12. Preliminary results of aerosols' properties studied with EPF measurements from the SPICAM/UV instrument

    Science.gov (United States)

    Willame, Yannick; Carine Vandaele, Ann; Depiesse, Cedric; Gillotay, Didier; Kochenova, Svetlana; Montmessin, Franck

    2013-04-01

    Aerosols on Mars have an important impact on the radiative transfer properties of its atmosphere. Today their spectral properties and therefore their interaction with UV radiation are only poorly known. Improving the radiative transfer modeling requires a better knowledge of their characteristics, in particular of their opacity, phase function and single scattering albedo. Part of such information can be accessed by using EPF observations. The SPICAM instrument on board of the Mars-Express satellite is a 2 channel spectrometer. One channel operates in the ultraviolet (118-320 nm) and the second one in the infrared (1.0-1.7μm). SPICAM has been orbiting around the red planet since 2003 and has thus provided a large set of data. The instrument is capable of measuring under different geometries (nadir, limb, occultation) and one of them, called EPF (Emission Phase Function), can be a tool to study aerosols' properties. We have developed a new retrieval algorithm for nadir measurements based on the radiative transfer model LIDORT. This new code performs simulations of spectra taking into account gas absorption, surface reflection and scattering by aerosols and gases. The retrieval method, based on the optimal estimation, allows us up to now to deduce the ozone column density, the aerosols' optical depth and the surface albedo (with fixed wavelength dependencies). We are developing our model further in order to better study the aerosols' characteristics using EPF observations, which consist in looking at the same point on the planet while the satellite moves along the orbit. As the attempt to study all the aerosols' properties simultaneously was not convincing, we started studying their opacity and the influence of its altitude distribution with the other characteristics fixed. We will present preliminary results of our study on aerosols' properties using EPF data from SPICAM.

  13. Characterization of a traceable profiler instrument for areal roughness measurement

    International Nuclear Information System (INIS)

    Thomsen-Schmidt, P

    2011-01-01

    A two-dimensional profiler instrument was designed and realized at the PTB (Physikalisch-Technische Bundesanstalt). The main function of the instrument is to provide traceable results in the field of roughness measurement. It is equipped with a linear moving stylus which is guided by precision air bearings. The moving part of the stylus has weight around 1 g and is carried by a magnetic field. The contacting force of the tip onto the surface under test is controlled by a small voice coil actuator in a closed control loop. Vertical movements of the stylus are captured by two different, completely independent measurement systems, covering a range of 100 µm. The first one is an interferometer, which provides a traceable signal, and the second one is an inductive measurement system. The signal from the inductive measurement system is calibrated by the interferometer. The sample under test is carried within the x–y-plane by a linear guided table with low noise air bearings. These air bearings are preloaded by vacuum and a constant gap is achieved by gas pressure controllers. Both axes of the table are driven by linear voice coil actuators and their movement in the plane is measured by linear encoders. The sample carrier is equipped with two axes tilt compensation, by which the sample under test can be levelled automatically using the measurement system of the stylus. Real-time data acquisition, manual handling and automated procedures are managed by a programmable controller and proprietary software written in LabVIEW. After measurement, data from the system can be directly transferred into the smd- or sdf-format. Results of measurements on different samples to characterize the metrological behaviour of the instrument will be reported. To characterize the uncertainty of the instrument, a model is applied, which is in accordance with approved rules for contact stylus instruments

  14. Smartphone measurement engineering - Innovative challenges for science & education, instrumentation & training

    Science.gov (United States)

    Hofmann, D.; Dittrich, P.-G.; Duentsch, E.

    2010-07-01

    Smartphones have an enormous conceptual and structural influence on measurement science & education, instrumentation & training. Smartphones are matured. They became convenient, reliable and affordable. In 2009 worldwide 174 million Smartphones has been delivered. Measurement with Smartphones is ready for the future. In only 10 years the German vision industry tripled its global sales volume to one Billion Euro/Year. Machine vision is used for mobile object identification, contactless industrial quality control, personalized health care, remote facility and transport management, safety critical surveillance and all tasks which are too complex for the human eye or too monotonous for the human brain. Aim of the paper is to describe selected success stories for the application of Smartphones for measurement engineering in science and education, instrumentation and training.

  15. Instrument for measuring metal-thermoelectric semiconductor contact resistence

    International Nuclear Information System (INIS)

    Lanxner, M.; Nechmadi, M.; Meiri, B.; Schildkraut, I.

    1979-02-01

    An instrument for measuring electrical, metal-thermoelectric semiconductor contact resistance is described. The expected errors of measurement are indicated. The operation of the instrument which is based on potential traversing perpendicularly to the contact plane is illustrated for the case of contacts of palladium and bismuth telluride-based thermoelectric material

  16. Development of a new densimeter for the combined investigation of dew-point densities and sorption phenomena of fluid mixtures

    Science.gov (United States)

    Moritz, Katharina; Kleinrahm, Reiner; McLinden, Mark O.; Richter, Markus

    2017-12-01

    For the determination of dew-point densities and pressures of fluid mixtures, a new densimeter has been developed. The new apparatus is based on the well-established two-sinker density measurement principle with the additional capability of quantifying sorption effects. In the vicinity of the dew line, such effects cause a change in composition of the gas mixture under study, which can significantly distort accurate density measurements. The new experimental technique enables the accurate measurement of dew-point densities and pressures and the quantification of sorption effects at the same time.

  17. Interactive FORTRAN IV computer programs for the thermodynamic and transport properties of selected cryogens (fluids pack)

    Science.gov (United States)

    Mccarty, R. D.

    1980-01-01

    The thermodynamic and transport properties of selected cryogens had programmed into a series of computer routines. Input variables are any two of P, rho or T in the single phase regions and either P or T for the saturated liquid or vapor state. The output is pressure, density, temperature, entropy, enthalpy for all of the fluids and in most cases specific heat capacity and speed of sound. Viscosity and thermal conductivity are also given for most of the fluids. The programs are designed for access by remote terminal; however, they have been written in a modular form to allow the user to select either specific fluids or specific properties for particular needs. The program includes properties for hydrogen, helium, neon, nitrogen, oxygen, argon, and methane. The programs include properties for gaseous and liquid states usually from the triple point to some upper limit of pressure and temperature which varies from fluid to fluid.

  18. Patient-reported outcome instruments that evaluate adherence behaviours in adults with asthma: A systematic review of measurement properties.

    Science.gov (United States)

    Gagné, Myriam; Boulet, Louis-Philippe; Pérez, Norma; Moisan, Jocelyne

    2018-04-30

    To systematically identify the measurement properties of patient-reported outcome instruments (PROs) that evaluate adherence to inhaled maintenance medication in adults with asthma. We conducted a systematic review of six databases. Two reviewers independently included studies on the measurement properties of PROs that evaluated adherence in asthmatic participants aged ≥18 years. Based on the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN), the reviewers (1) extracted data on internal consistency, reliability, measurement error, content validity, structural validity, hypotheses testing, cross-cultural validity, criterion validity, and responsiveness; (2) assessed the methodological quality of the included studies; (3) assessed the quality of the measurement properties (positive or negative); and (4) summarised the level of evidence (limited, moderate, or strong). We screened 6,068 records and included 15 studies (14 PROs). No studies evaluated measurement error or responsiveness. Based on methodological and measurement property quality assessments, we found limited positive evidence of: (a) internal consistency of the Adherence Questionnaire, Refined Medication Adherence Reason Scale (MAR-Scale), Medication Adherence Report Scale for Asthma (MARS-A), and Test of the Adherence to Inhalers (TAI); (b) reliability of the TAI; and (c) structural validity of the Adherence Questionnaire, MAR-Scale, MARS-A, and TAI. We also found limited negative evidence of: (d) hypotheses testing of Adherence Questionnaire; (e) reliability of the MARS-A; and (f) criterion validity of the MARS-A and TAI. Our results highlighted the need to conduct further high-quality studies that will positively evaluate the reliability, validity, and responsiveness of the available PROs. This article is protected by copyright. All rights reserved.

  19. Neutron measuring instruments for radiation protection

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Schneider, W.; Hoefert, M.; Kuehn, H.; Jahr, R.; Wagner, S.; Piesch, E.

    1979-09-01

    The present report deals with selected topics from the field of neutron dosimetry for radiation protection connected with the work of the subcommittee 6802 in the Standards Committee on Radiology (NAR) of the German Standards Institute (DIN). It is a sort of material collection. The topics are: 1. Measurement of the absorbed-energy dose by a) ionization chambers in fields of mixed radiation and b) recoil-proton proportional counting tubes. 2. Measurement of the equivalent dose, neutron monitors, combination methods by a) rem-meters, b) recoil-proton counting tubes, c) recombination method, tissue-equivalent proportional counters, activation methods for high energies in fields of mixed radiation, d) personnel dosimetry by means of ionization chambers and counting tubes, e) dosimetry by means of activation methods, nuclear track films, nonphotographic nuclear track detectors and solid-state dosimeters. (orig./HP) [de

  20. A digital instrument for reactivity measurements in a nuclear reactor

    International Nuclear Information System (INIS)

    Chwaszczewski, S.

    1979-01-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given. (author)

  1. Digital instrument for reactivity measurements in a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chwaszczewski, S [Institute of Nuclear Research, Warsaw (Poland)

    1979-07-01

    An instrument for digital determination of the reactivity in nuclear reactors is described. It is based on the CAMAC standard apparatus, suitable for the use of pulse or current type neutron detectors and operates with prompt response and an output signal proportional to the core neutron flux. The measured data of neutron flux and reactivity can be registered by a digital display unit, an indicator, or, by request of the operator, a paper type punch. The algorithms used for reactivity calculation are considered and the results of numerical studies on those algorithms are discussed. The instrument has been used for determining the reactivity of the control elements in the fast-thermal assembly ANNA and in the research reactor MARIA. Some results of these measurements are given.

  2. MODERN INSTRUMENTS FOR MEASURING ORGANIZATIONAL PERFORMANCE

    Directory of Open Access Journals (Sweden)

    RADU CATALINA

    2010-12-01

    Full Text Available Any significant management action can be assessed both in terms of success of immediate goals and as effect of the organization ability to embrace change. Market competition intensifies with the development of Romanian society and its needs. Companies that offer different products and services need to impose certain advantages and to increase their performances. The paper will present modern tools for measuring and evaluating organizational performance, namely: Balanced Scorecard, Deming model and Baldrige model. We also present an example for Balance Scorecard, of an organizations belonging to the cosmetics industry.

  3. Mercury-free PVT apparatus for thermophysical property analyses of hydrocarbon reservoir fluids

    Energy Technology Data Exchange (ETDEWEB)

    Lansangan, R.M.; Lievois, J.S.

    1992-08-31

    Typical reservoir fluid analyses of complex, multicomponent hydrocarbon mixtures include the volumetric properties, isothermal compressibility, thermal expansivity, equilibrium ratios, saturation pressure, viscosities, etc. These parameters are collectively referred to as PVT properties, an acronym for the primary state variables; pressure, volume, and temperature. The reservoir engineer incorporates this information together with the porous media description in performing material balance calculations. These calculations lead to the determination (estimation) of the initial hydrocarbon in-place, the future reservoir performance, the optimal production scheme, and the ultimate hydrocarbon recovery. About four years ago, Ruska Instrument Corporation embarked on a project to develop an apparatus designed to measure PVT properties that operates free of mercury. The result of this endeavor is the 2370 Hg-Free PVT system which has been in the market for the last three years. The 2370 has evolved from the prototype unit to its present configuration which is described briefly in this report. The 2370 system, although developed as a system-engineered apparatus based on existing technology, has not been exempt from this burden-of-proof Namely, the performance of the apparatus under routine test conditions with real reservoir fluids. This report summarizes the results of the performance and applications testing of the 2370 Hg-Free PVT system. Density measurements were conducted on a pure fluid. The results were compared against literature values and the prediction of an equation of state. Routine reservoir fluid analyses were conducted with a black oil and a retrograde condensate gas mixtures. Limited comparison of the results were performed based on the same tests performed on a conventional mercury-based PVT apparatus. The results of these tests are included in this report.

  4. Fluid models and simulations of biological cell phenomena

    Science.gov (United States)

    Greenspan, H. P.

    1982-01-01

    The dynamics of coated droplets are examined within the context of biofluids. Of specific interest is the manner in which the shape of a droplet, the motion within it as well as that of aggregates of droplets can be controlled by the modulation of surface properties and the extent to which such fluid phenomena are an intrinsic part of cellular processes. From the standpoint of biology, an objective is to elucidate some of the general dynamical features that affect the disposition of an entire cell, cell colonies and tissues. Conventionally averaged field variables of continuum mechanics are used to describe the overall global effects which result from the myriad of small scale molecular interactions. An attempt is made to establish cause and effect relationships from correct dynamical laws of motion rather than by what may have been unnecessary invocation of metabolic or life processes. Several topics are discussed where there are strong analogies droplets and cells including: encapsulated droplets/cell membranes; droplet shape/cell shape; adhesion and spread of a droplet/cell motility and adhesion; and oams and multiphase flows/cell aggregates and tissues. Evidence is presented to show that certain concepts of continuum theory such as suface tension, surface free energy, contact angle, bending moments, etc. are relevant and applicable to the study of cell biology.

  5. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1989-08-01

    The purpose of the research is to extend the theory of critical phenomena in fluids and fluid mixtures to obtain scientifically based equations that include the crossover from the asymptotic singular behavior of the thermophysical properties close to the critical point to the regular behavior of these properties far away from the critical point

  6. 40 CFR 86.120-94 - Gas meter or flow instrumentation calibration; particulate, methanol and formaldehyde measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... Procedures § 86.120-94 Gas meter or flow instrumentation calibration; particulate, methanol and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters...

  7. An intelligent instrument for measuring the dynamic parameters of groundwater

    International Nuclear Information System (INIS)

    Du Guoping

    2002-01-01

    An intelligent instrument was developed for measuring direction and velocity of the groundwater, permeability coefficient, hydraulic transmitting coefficient, static level, hydraulic gradient and flow direction of each layer. The instrument can be widely applied for detecting seepage of abutment and river bank, exploitation of groundwater, conservation of water and soil, water surging in mine, survey of groundwater resource and environment protection etc

  8. An instrumentation for control and measurement of activated mineral samples

    International Nuclear Information System (INIS)

    Skaarup, P.

    1976-01-01

    A description is given of an instrumentation for control of a pneumatic tube system used to transport mineral samples for activation in a reactor and from there to a detector arrangement. A possible content of uranium in the samples can be seen from the radiation measured. The instrumentation includes a PDP-11 computer and a CAMAC crate

  9. Instrumentation for localized measurements in two-phase flow conditions

    International Nuclear Information System (INIS)

    Neff, G.G.; Averill, R.H.; Shurts, S.W.

    1979-01-01

    Three types of instrumentation that have been developed by EG and G Idaho, Inc., and its predecessor, Aerojet Nuclear company, at the Idaho National Engineering Laboratory to investigate two-phase flow phenomenon in a nuclear reactor at the Loss-of-Fluid Test (LOFT) facility are discussed: (a) a combination drag disc-turbine transducer (DTT), (b) a multibeam nuclear hardened gamma densitometer system, and (c) a conductivity sensitive liquid level transducer (LLT). The DTT obtains data on the complex problem of two-phase flow conditions in the LOFT primary coolant system during a loss-os-coolant experiment (LOCE). The discussion of the DTT describes how a turbine, measuring coolant velocity, and a drag disc, measuring coolant momentum flux, can provide valuable mass flow data. The nuclear hardened gamma densitometer is used to obtain density and flow regime information for two-phase flow in the LOFT primary coolant system during a LOCE. The LLT is used to measure water and steam conditions within the LOFT reactor core during a LOCE. The LLT design and the type of data obtained are described

  10. Advanced Measuring (Instrumentation Methods for Nuclear Installations: A Review

    Directory of Open Access Journals (Sweden)

    Wang Qiu-kuan

    2012-01-01

    Full Text Available The nuclear technology has been widely used in the world. The research of measurement in nuclear installations involves many aspects, such as nuclear reactors, nuclear fuel cycle, safety and security, nuclear accident, after action, analysis, and environmental applications. In last decades, many advanced measuring devices and techniques have been widely applied in nuclear installations. This paper mainly introduces the development of the measuring (instrumentation methods for nuclear installations and the applications of these instruments and methods.

  11. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  12. Densimetry for the Quantification of Sorption Phenomena on Nonporous Media Near the Dew Point of Fluid Mixtures.

    Science.gov (United States)

    Richter, Markus; McLinden, Mark O

    2017-07-21

    Phase equilibria of fluid mixtures are important in numerous industrial applications and are, thus, a major focus of thermophysical property research. Improved data, particularly along the dew line, are needed to improve model predictions. Here we present experimental results utilizing highly accurate densimetry to quantify the effects of sorption and capillary condensation, which exert a distorting influence on measured properties near the dew line. We investigate the (pressure, density, temperature, composition) behaviour of binary (CH 4  + C 3 H 8 ) and (Ar + CO 2 ) mixtures over the temperature range from (248.15 to 273.15) K starting at low pressures and increasing in pressure towards the dew point along isotherms. Three distinct regions are observed: (1) minor sorption effects in micropores at low pressures; (2) capillary condensation followed by wetting in macro-scale surface scratches beginning approximately 2% below the dew-point pressure; (3) bulk condensation. We hypothesize that the true dew point lies within the second region.

  13. Psychometric Properties of an Instrument to Measure Mother-Infant Togetherness After Childbirth.

    Science.gov (United States)

    Lawrence, Carol L; Norris, Anne E

    2016-01-01

    The purpose of this research was to evaluate the psychometric properties of a new instrument to measure mother-infant togetherness, Mother-Infant Togetherness Survey (MITS). Stage 1 examined content validity. Stage 2 pretested the readability and understandability and further examined content validity. Stage 3 examined women's ability to accurately self-report on the Delivery Events subscale. Stages 4 and 5 examined construct validity. Good content validity was obtained at the scale/subscale level (CVI = .91-1.00). Internal consistency reliability was evaluated at the scale/subscale level (α = .62-.89). Construct validity was supported with known groups testing and factor analysis. Study findings provide support for the reliability and validity of the MITS. Future research should be done to improve the internal consistency reliability of the Postpartum Events subscale.

  14. The Stokes boundary layer for a thixotropic or antithixotropic fluid

    KAUST Repository

    McArdle, Catriona R.

    2012-10-01

    We present a mathematical investigation of the oscillatory boundary layer in a semi-infinite fluid bounded by an oscillating wall (the so-called \\'Stokes problem\\'), when the fluid has a thixotropic or antithixotropic rheology. We obtain asymptotic solutions in the limit of small-amplitude oscillations, and we use numerical integration to validate the asymptotic solutions and to explore the behaviour of the system for larger-amplitude oscillations. The solutions that we obtain differ significantly from the classical solution for a Newtonian fluid. In particular, for antithixotropic fluids the velocity reaches zero at a finite distance from the wall, in contrast to the exponential decay for a thixotropic or a Newtonian fluid.For small amplitudes of oscillation, three regimes of behaviour are possible: the structure parameter may take values defined instantaneously by the shear rate, or by a long-term average; or it may behave hysteretically. The regime boundaries depend on the precise specification of structure build-up and breakdown rates in the rheological model, illustrating the subtleties of complex fluid models in non-rheometric settings. For larger amplitudes of oscillation the dominant behaviour is hysteretic. We discuss in particular the relationship between the shear stress and the shear rate at the oscillating wall. © 2012 Elsevier B.V.

  15. Implementation outcome assessment instruments used in physical healthcare settings and their measurement properties: a systematic review protocol.

    Science.gov (United States)

    Khadjesari, Zarnie; Vitoratou, Silia; Sevdalis, Nick; Hull, Louise

    2017-10-08

    Over the past 10 years, research into methods that promote the uptake, implementation and sustainability of evidence-based interventions has gathered pace. However, implementation outcomes are defined in different ways and assessed by different measures; the extent to which these measures are valid and reliable is unknown. The aim of this systematic review is to identify and appraise studies that assess the measurement properties of quantitative implementation outcome instruments used in physical healthcare settings, to advance the use of precise and accurate measures. The following databases will be searched from inception to March 2017: MEDLINE, EMBASE, PsycINFO, CINAHL and the Cochrane Library. Grey literature will be sought via HMIC, OpenGrey, ProQuest for theses and Web of Science Conference Proceedings Citation Index-Science. Reference lists of included studies and relevant reviews will be hand searched. Three search strings will be combined to identify eligible studies: (1) implementation literature, (2) implementation outcomes and (3) measurement properties. Screening of titles, abstracts and full papers will be assessed for eligibility by two reviewers independently and any discrepancies resolved via consensus with the wider team. The methodological quality of the studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. A set of bespoke criteria to determine the quality of the instruments will be used, and the relationship between instrument usability and quality will be explored. Ethical approval is not necessary for systematic review protocols. Researchers and healthcare professionals can use the findings of this systematic review to guide the selection of implementation outcomes instruments, based on their psychometric quality, to assess the impact of their implementation efforts. The findings will also provide a useful guide for reviewers of papers and grants to determine the

  16. Neutron multiplication measurement instrument

    International Nuclear Information System (INIS)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1983-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results

  17. Instrument for Airborne Measurement of Carbonyl Sulfide, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Southwest Sciences proposes to develop small, low power instrumentation for the real-time direct measurement of carbonyl sulfide (OCS) in the atmosphere, especially...

  18. Instrument for Airborne Measurement of Carbonyl Sulfide, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II SBIR program, Southwest Sciences will continue the development of small, low power instrumentation for real-time direct measurement of carbonyl...

  19. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  20. Design Considerations for Remote High-Speed Pressure Measurements of Dynamic Combustion Phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Straub, D.L.; Ferguson, D.H.; Rohrssen, Robert (West Virginia University, Morgantown, WV); Perez, Eduardo (West Virginia University, Morgantown, WV)

    2007-01-01

    As gas turbine combustion systems evolve to achieve ultra-low emission targets, monitoring and controlling dynamic combustion processes becomes increasingly important. These dynamic processes may include flame extinction, combustion-driven instabilities, or other dynamic combustion phenomena. Pressure sensors can be incorporated into the combustor liner design, but this approach is complicated by the harsh operating environment. One practical solution involves locating the sensor in a more remote location, such as outside the pressure casing. The sensor can be connected to the measurement point by small diameter tubing. Although this is a practical approach, the dynamics of the tubing can introduce significant errors into the pressure measurement. This paper addresses measurement errors associated with semi-infinite coil remote sensing setups and proposes an approach to improve the accuracy of these types of measurements.

  1. Computational transport phenomena of fluid-particle systems

    CERN Document Server

    Arastoopour, Hamid; Abbasi, Emad

    2017-01-01

    This book concerns the most up-to-date advances in computational transport phenomena (CTP), an emerging tool for the design of gas-solid processes such as fluidized bed systems. The authors examine recent work in kinetic theory and CTP and illustrate gas-solid processes’ many applications in the energy, chemical, pharmaceutical, and food industries. They also discuss the kinetic theory approach in developing constitutive equations for gas-solid flow systems and how it has advanced over the last decade as well as the possibility of obtaining innovative designs for multiphase reactors, such as those needed to capture CO2 from flue gases. Suitable as a concise reference and a textbook supplement for graduate courses, Computational Transport Phenomena of Gas-Solid Systems is ideal for practitioners in industries involved with the design and operation of processes based on fluid/particle mixtures, such as the energy, chemicals, pharmaceuticals, and food processing. Explains how to couple the population balance e...

  2. A systematic review of clinimetric properties of measurements of motivation for children aged 5-16 years with a physical disability or motor delay.

    Science.gov (United States)

    Miller, Laura; Ziviani, Jenny; Boyd, Roslyn Nancy

    2014-02-01

    The purpose of this systematical review was to appraise the clinimetric properties of measures of motivation in children aged 5-16 years with a physical disability or motor delay. Six electronic databases were searched. Studies were included if they reported measuring motivation in school-aged children across occupational performance areas. Two reviewers independently identified measures from included articles. Evaluation of measures was completed using the COSMIN (consensus-based standards for the selection of health measurement instruments) checklist. A total of 13,529 papers were retrieved, 15 reporting measurement of motivation in this population. Two measures met criteria: Dimensions of Mastery Questionnaire (DMQ) and Pediatric Volitional Questionnaire (PVQ). There was evidence of adequate validity for DMQ, and preliminary evidence of test-retest reliability. Psychometric evidence for PVQ was poor. Both measures demonstrated good clinical utility. The large number of retrieved papers highlights the importance being attributed to motivation in clinical studies, although measurement is seldom performed. Both identified measures show promise but further psychometric research is required.

  3. Measuring Asian nurses' organizational commitment: a critical analysis of the psychometric properties of two organizational commitment instruments.

    Science.gov (United States)

    Liou, Shwu-Ru; Tsai, Hsiu-Min; Cheng, Ching-Yu

    2013-01-01

    To analyze and compare the psychometric properties and cultural attributes of the Organizational Commitment Questionnaire and the Organizational Commitment Scale to determine their appropriateness for measuring commitment of Asian nurses, the biggest portion of international nurses. The Organizational Commitment Questionnaire was cross-culturally cross-validated when compared with the Organizational Commitment Scale. Both instruments were not tested on Asian nurses. More studies are needed to validate the cultural properties of the Organizational Commitment Scale. Healthcare administrators can use culturally validated instruments, which concern cultural context, including languages and cultural values, to understand Asian nurses' organizational commitment and further lower turnover behavior among them. © 2013 Wiley Periodicals, Inc.

  4. Instrumentation for radon measurement and diagnosis

    International Nuclear Information System (INIS)

    Whyte, N.; Ellacott, K.; Brabant, L.

    1990-01-01

    Knowledge of existing protocols and guidelines, coupled with equipment acumen can make for a successful endeavor in the radon field. But where do you collect a users perspective on radon equipment? Obtaining a first hand understanding of how radon detection equipment may be applied can be a lengthy and expensive process. In this paper first principals of progeny collection, and counting, are covered. Use of Thomson and Nielsen equipment to screen, and diagnose radon will e presented. Equipment performance in a wide variety of field applications and in calibration chambers will be brought to light. The distinctive nature and versatility of the equipment will e outlined with applications information, system performance, and unique configurations

  5. Parents' attitudes towards topical fluoride and vaccines for children: Are these distinct or overlapping phenomena?

    Directory of Open Access Journals (Sweden)

    Richard M. Carpiano

    2018-06-01

    Full Text Available Despite attention paid to parental refusal of child vaccines, the phenomenon of topical fluoride refusal is poorly understood. We examine the extent to which parent attitudes and Internet use regarding topical fluoride treatment and vaccines may overlap and, in turn, uniquely or distinctly correlate with fluoride and vaccine refusal for the child. In 2017, we analyzed data collected from 2011 to 12 for 361 children from three Washington state dental clinics. The instrument included analogous measures of topical fluoride and vaccine safety concerns, perceived severity of preventable cavities/disease, and Internet use for fluoride/vaccine information; and measures of non-fluoridated toothpaste use, attitudes towards dental x-rays and amalgam and composite fillings. We assessed dental chart-based topical fluoride refusal occurring in 2009 or 2010 and parent-reported vaccine refusal. All analogous fluoride and vaccine items were substantively correlated. However, in a series of adjusted models, none of these items were significantly associated with fluoride refusal. Multiple fluoride and vaccine items were associated with vaccine refusal in unadjusted models; but only vaccine safety concerns, perceived severity of a preventable cavity, and Internet use for vaccine information remained significant in adjusted models. Although there is concordance between the two refusal behaviors as well as analogous attitudes and Internet use, these findings challenge the idea that fluoride refusal should be addressed with interventions focusing on vaccine refusal. Further research is required on the factors underlying refusal of preventive dental care. Keywords: Vaccinations, Topical fluoride, Vaccination refusal, Fluoride refusal, Vaccine hesitancy, Fluoride hesitancy, Children, Adolescents, Preventive treatment, United States

  6. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  7. Instrumentation for collecting and measuring radon and its daughters

    International Nuclear Information System (INIS)

    Essling, M.A.; Hengde, W.; Markun, F.; Toohey, R.E.; Rundo, J.; Miranda, J.E. Jr.

    1982-01-01

    A new sampling can is described for collecting an air sample for determination of its radon content. Instruments which are employed for the continuous monitoring of radon or its daughters in houses are described and their performances discussed

  8. Overview of LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed

  9. An instrument for X-ray set quality assurance measurements

    International Nuclear Information System (INIS)

    Willetts, R.J.; West, M.B.; Brydon, J.

    1989-01-01

    This paper describes a prototype electronic instrument for performing quality assurance (QA) measurements on diagnostic radiological equipment with a view to long-term performance assessment on a Regional basis. The instrument is based on a Tandy 200 laptop computer and has been developed primarily to include the assessment of image intensifier/TV systems in a general QA package. It is capable of accepting signals from the following sources: (1) a radiation detector (diode array); (2) a Keithley kV divider (Keithley Instruments, Inc.); (3) the video output of an image intensifier system. (author)

  10. Core outcome measurement instruments for clinical trials in nonspecific low back pain

    Science.gov (United States)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A.; Buchbinder, Rachelle; Corbin, Terry P.; Costa, Leonardo O.P.; Foster, Nadine E.; Grotle, Margreth; Koes, Bart W.; Kovacs, Francisco M.; Lin, C.-W. Christine; Maher, Chris G.; Pearson, Adam M.; Peul, Wilco C.; Schoene, Mark L.; Turk, Dennis C.; van Tulder, Maurits W.; Terwee, Caroline B.; Ostelo, Raymond W.

    2018-01-01

    Abstract To standardize outcome reporting in clinical trials of patients with nonspecific low back pain, an international multidisciplinary panel recommended physical functioning, pain intensity, and health-related quality of life (HRQoL) as core outcome domains. Given the lack of a consensus on measurement instruments for these 3 domains in patients with low back pain, this study aimed to generate such consensus. The measurement properties of 17 patient-reported outcome measures for physical functioning, 3 for pain intensity, and 5 for HRQoL were appraised in 3 systematic reviews following the COSMIN methodology. Researchers, clinicians, and patients (n = 207) were invited in a 2-round Delphi survey to generate consensus (≥67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In round 1, consensus was achieved on the Oswestry Disability Index version 2.1a for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In round 2, a consensus was reached on an NRS version with a 1-week recall period (96% agreement). Various participants requested 1 free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: Oswestry Disability Index version 2.1a or 24-item Roland-Morris Disability Questionnaire for physical functioning, NRS for pain intensity, and SF12 or 10-item PROMIS Global Health form for HRQoL. Further studies need to fill the evidence gaps on the measurement properties of these and other instruments. PMID:29194127

  11. Development of material measures for performance verifying surface topography measuring instruments

    International Nuclear Information System (INIS)

    Leach, Richard; Giusca, Claudiu; Rickens, Kai; Riemer, Oltmann; Rubert, Paul

    2014-01-01

    The development of two irregular-geometry material measures for performance verifying surface topography measuring instruments is described. The material measures are designed to be used to performance verify tactile and optical areal surface topography measuring instruments. The manufacture of the material measures using diamond turning followed by nickel electroforming is described in detail. Measurement results are then obtained using a traceable stylus instrument and a commercial coherence scanning interferometer, and the results are shown to agree to within the measurement uncertainties. The material measures are now commercially available as part of a suite of material measures aimed at the calibration and performance verification of areal surface topography measuring instruments

  12. Development of retrieval, reservation and management system for measuring instruments

    International Nuclear Information System (INIS)

    Tsuda, Kenzo; Ito, Emi.

    1985-08-01

    In order to computerize the lending and management of measuring instruments, at first, the specification of the software was examined, but thereafter, the development was begun. The largest aim of the computerization was the automation and labor saving of the lending works of diverse measuring instruments and the automatic management. From user side, it is desirable to know the specification and the state of use and reservation of measuring instruments and to be able to easily make reservation based on the information. Besides, from management side, it is desirable to know the location and the state of use and reservation of measuring instruments, to immediately prepare for lending and returning, and to automate the recording of lending and returning. So as to satisfy those conditions, the automatic reservation and management system for measuring instruments was developed. At the same time, the means to simply input required data such as specification, names of manufacturers and equipment number was developed. The input of data was carried out for three months from October, 1984, and the system was almost completed in December, 1984. The full scale operation was started in Junuary, 1985. (Kako, I.)

  13. Measurement of activity limitations and participation restrictions: examination of ICF-linked content and scale properties of the FIM and PC-PART instruments.

    Science.gov (United States)

    Darzins, Susan W; Imms, Christine; Di Stefano, Marilyn

    2017-05-01

    To explore the operationalization of activity and participation-related measurement constructs through comparison of item phrasing, item response categories and scoring (scale properties) for two separate instruments targeting activities of daily living. Personal Care Participation Assessment and Resource Tool (PC-PART) item content was linked to ICF categories using established linking rules. Previously reported ICF-linked FIM content categories and ICF-linked PC-PART content categories were compared to identify common ICF categories between the instruments. Scale properties of both instruments were compared using a patient scenario to explore the instruments' separate measurement constructs. The PC-PART and FIM shared 15 of the 53 level two ICF-linked categories identified across both instruments. Examination of the instruments' scale properties for items with overlapping ICF content, and exploration through a patient scenario, provided supportive evidence that the instruments measure different constructs. While the PC-PART and FIM share common ICF-linked content, they measure separate constructs. Measurement construct was influenced by the instruments' scale properties. The FIM was observed to measure activity limitations and the PC-PART measured participation restrictions. Scrutiny of instruments' scale properties in addition to item content is critical in the operationalization of activity and participation-related measurement constructs. Implications for Rehabilitation When selecting outcome measures for use in rehabilitation it is necessary to examine both the content of the instruments' items and item phrasing, response categories and scoring, to clarify the construct being measured. Measurement of activity limitations as well as participation restrictions in activities of daily living required for community life provides a more comprehensive measurement of rehabilitation outcomes than measurement of either construct alone. To measure the effects of

  14. Critical properties of effective gauge theories for novel quantum fluids

    Energy Technology Data Exchange (ETDEWEB)

    Smoergrav, Eivind

    2005-07-01

    ;light vortices') loose co centricity with the vortices with large phase stiffness ('heavy vortices'), entering a liquid state. Paper 7: The phase diagram and critical properties of the N-component London superconductor are studied in zero and finite magnetic field. Direct and dual gauge field correlators for general N are given. The model with N = 3 exhibits three anomalies in the specific heat. We demonstrate the existence of two neutral 3D XY fixed points and one inverted charged 3D XY fixed point. In particular, for N = 2 we point out the possibility of two novel types of field induced phase transitions in ordered quantum fluids: 1) A phase transition from a superconductor to a superfluid or vice versa, driven by tuning an external magnetic field. This identifies the superconducting phase of liquid metallic hydrogen as a novel quantum fluid. 2) A phase transition corresponding to a quantum fluid analogue of sub-lattice melting, where a composite field induced Abrikosov vortex lattice is decomposed and disorders the phases of the constituent condensate with lowest bare phase stiffness. Both transitions belong to the 3D XY universality class. Paper 8: We study the phase structure of a 2-component superconductor in a high magnetic field. We identify a regime where first, at a certain temperature a field induced lattice of co centered vortices of both order parameters melts, causing the system to loose superconductivity (author)(tk)

  15. New Platforms for Suborbital Astronomical Observations and In Situ Atmospheric Measurements: Spacecraft, Instruments, and Facilities

    Science.gov (United States)

    Rodway, K.; DeForest, C. E.; Diller, J.; Vilas, F.; Sollitt, L. S.; Reyes, M. F.; Filo, A. S.; Anderson, E.

    2014-12-01

    Suborbital astronomical observations have over 50 years' history using NASA's sounding rockets and experimental space planes. The new commercial space industry is developing suborbital reusable launch vehicles (sRLV's) to provide low-cost, flexible, and frequent access to space at ~100 km altitude. In the case of XCOR Aerospace's Lynx spacecraft, the vehicle design and capabilities work well for hosting specially designed experiments that can be flown with a human-tended researcher or alone with the pilot on a customized mission. Some of the first-generation instruments and facilities that will conduct solar observations on dedicated Lynx science missions include the SwRI Solar Instrument Pointing Platform (SSIPP) and Atsa Suborbital Observatory, as well as KickSat sprites, which are picosatellites for in situ atmospheric and solar phenomena measurements. The SSIPP is a demonstration two-stage pointed solar observatory that operates inside the Lynx cockpit. The coarse pointing stage includes the pilot in the feedback loop, and the fine stage stabilizes the solar image to achieve arcsecond class pointing. SSIPP is a stepping-stone to future external instruments that can operate with larger apertures and shorter wavelengths in the solar atmosphere. The Planetary Science Institute's Atsa Suborbital Observatory combines the strengths of ground-based observatories and space-based observing to create a facility where a telescope is maintained and used interchangeably with either in-house facility instruments or user-provided instruments. The Atsa prototype is a proof of concept, hand-guided camera that mounts on the interior of the Lynx cockpit to test target acquisition and tracking for human-operated suborbital astronomy. KickSat sprites are mass-producible, one inch printed circuit boards (PCBs) populated by programmable off the shelf microprocessors and radios for real time data transmission. The sprite PCBs can integrate chip-based radiometers, magnetometers

  16. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  17. Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

    Science.gov (United States)

    Upchurch, Billy T.; Wood, George M.; Brown, Kenneth G.; Burns, Karen S.

    1993-01-01

    A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

  18. Implementation outcome assessment instruments used in physical healthcare settings and their measurement properties: a systematic review protocol

    Science.gov (United States)

    Vitoratou, Silia; Sevdalis, Nick; Hull, Louise

    2017-01-01

    Introduction Over the past 10 years, research into methods that promote the uptake, implementation and sustainability of evidence-based interventions has gathered pace. However, implementation outcomes are defined in different ways and assessed by different measures; the extent to which these measures are valid and reliable is unknown. The aim of this systematic review is to identify and appraise studies that assess the measurement properties of quantitative implementation outcome instruments used in physical healthcare settings, to advance the use of precise and accurate measures. Methods and analysis The following databases will be searched from inception to March 2017: MEDLINE, EMBASE, PsycINFO, CINAHL and the Cochrane Library. Grey literature will be sought via HMIC, OpenGrey, ProQuest for theses and Web of Science Conference Proceedings Citation Index-Science. Reference lists of included studies and relevant reviews will be hand searched. Three search strings will be combined to identify eligible studies: (1) implementation literature, (2) implementation outcomes and (3) measurement properties. Screening of titles, abstracts and full papers will be assessed for eligibility by two reviewers independently and any discrepancies resolved via consensus with the wider team. The methodological quality of the studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. A set of bespoke criteria to determine the quality of the instruments will be used, and the relationship between instrument usability and quality will be explored. Ethics and dissemination Ethical approval is not necessary for systematic review protocols. Researchers and healthcare professionals can use the findings of this systematic review to guide the selection of implementation outcomes instruments, based on their psychometric quality, to assess the impact of their implementation efforts. The findings will also provide a useful guide for

  19. Quality-of-life measures for use within care homes: a systematic review of their measurement properties.

    Science.gov (United States)

    Aspden, Trefor; Bradshaw, Siobhan A; Playford, E Diane; Riazi, Afsane

    2014-09-01

    the aims of this review were (i) to identify quality-of-life (QoL) measures which have had their measurement properties validated in people residing in care homes or nursing homes, and to critically compare and summarise these instruments and (ii) to make recommendations for measurement instruments. bibliographic databases PsycINFO, PubMed, Cochrane, CINAHL and Embase were searched for articles evaluating measurement properties of QoL instruments in people residing in care homes. Methodological quality of studies was assessed using the consensus-based standards for the selection of health measurement instruments checklist. Measurement properties of instruments were appraised using a systematic checklist. the search strategy resulted in 3252 unique citations, of which 15 articles were included in this review. These articles assessed 13 instruments, 8 of which were dementia or Alzheimer specific instruments. The QUALIDEM, a dementia-specific observational instrument, had the widest array of information available on its measurement properties, which were mostly satisfactory. Most measurement instruments lacked information on hypotheses testing and content validity. Information on responsiveness and measurement error was not available for any instrument. for people with dementia living in care homes, the QUALIDEM is recommended for measuring QoL. For residents without dementia, we recommend Kane et al.'s Psychosocial Quality of Life Domains questionnaire. Studies of higher methodological quality, assessing a wider range of measurement properties are needed to allow a more fully informed choice of QoL instrument. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. The Applicability of Different Fluid Media to Measure Effective Stress Coefficient for Rock Permeability

    Directory of Open Access Journals (Sweden)

    Ying Wang

    2015-01-01

    Full Text Available Effective stress coefficient for permeability (ESCK is the key parameter to evaluate the properties of reservoir stress sensitivity. So far, little studies have clarified which ESCK is correct for a certain reservoir while rock ESCK is measured differently by different fluid media. Thus, three different fluids were taken to measure a fine sandstone sample’s ESCK, respectively. As a result, the ESCK was measured to be the smallest by injecting nitrogen, the largest by injecting water, and between the two by brine. Besides, those microcharacteristics such as rock component, clay mineral content, and pore structure were further analyzed based on some microscopic experiments. Rock elastic modulus was reduced when water-sensitive clay minerals were encountered with aqua fluid media so as to enlarge the rock ESCK value. Moreover, some clay minerals reacting with water can spall and possibly block pore throats. Compared with water, brine can soften the water sensitivity; however, gas has no water sensitivity effects. Therefore, to choose which fluid medium to measure reservoir ESCK is mainly depending on its own exploitation conditions. For gas reservoirs using gas to measure ESCK is more reliable than water or brine, while using brine is more appropriate for oil reservoirs.

  1. The Construct Validity of an Instrument for Measuring Type 2 ...

    African Journals Online (AJOL)

    Abstract. Purpose: To develop an instrument (DSCKQ-30) for measuring type 2 diabetic patients' knowledge of self-care practices. Methods: A 30-item questionnaire (DSCKQ-30) consisting of close ended questions was developed for this study. DSCKQ-30 was self administered to a cross-section of randomly selected 400 ...

  2. An intelligent instrument for measuring exhaust temperature of marine engine

    Science.gov (United States)

    Ma, Nan-Qi; Su, Hua; Liu, Jun

    2006-12-01

    Exhaust temperature of the marine engine is commonly measured through thermocouple. Measure deviation will occur after using the thermocouple for some time due to nonlinearity of thermocouple itself, high temperature and chemical corrosion of measure point. Frequent replacement of thermocouple will increase the operating cost. This paper designs a new intelligent instrument for solving the above-mentioned problems of the marine engine temperature measurement, which combines the conventional thermocouple temperature measurement technology and SCM(single chip microcomputer). The reading of the thermocouple is simple and precise and the calibration can be made automatically and manually.

  3. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Science.gov (United States)

    Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose

    2014-03-01

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  4. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Energy Technology Data Exchange (ETDEWEB)

    Vacas-Jacques, Paulino [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Linnes, Jacqueline [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Biomedical Engineering Department, Boston University, Boston, Massachusetts 02215 (United States); Young, Anna; Gomez-Marquez, Jose [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Gerrard, Victoria [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Opportunity Lab, Singapore University for Technology and Design, Singapore 138682 (Singapore)

    2014-03-15

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  5. On-line fast response device and method for measuring dissolved gas in a fluid

    Science.gov (United States)

    Tutu, Narinder Kumar [Manorville, NY

    2011-01-11

    A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

  6. Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures

    Science.gov (United States)

    Fesmire, James; Sass, Jared; Johnson, Wesley

    2010-01-01

    With the advance of polymer and other non-metallic material sciences, whole new series of polymeric materials and composites are being created. These materials are being optimized for many different applications including cryogenic and low-temperature industrial processes. Engineers need these data to perform detailed system designs and enable new design possibilities for improved control, reliability, and efficiency in specific applications. One main area of interest is cryogenic structural elements and fluid handling components and other parts, films, and coatings for low-temperature application. An important thermal property of these new materials is the apparent thermal conductivity (k-value).

  7. An inexpensive instrument for measuring wave exposure and water velocity

    Science.gov (United States)

    Figurski, J.D.; Malone, D.; Lacy, J.R.; Denny, M.

    2011-01-01

    Ocean waves drive a wide variety of nearshore physical processes, structuring entire ecosystems through their direct and indirect effects on the settlement, behavior, and survivorship of marine organisms. However, wave exposure remains difficult and expensive to measure. Here, we report on an inexpensive and easily constructed instrument for measuring wave-induced water velocities. The underwater relative swell kinetics instrument (URSKI) is a subsurface float tethered by a short (<1 m) line to the seafloor. Contained within the float is an accelerometer that records the tilt of the float in response to passing waves. During two field trials totaling 358 h, we confirmed the accuracy and precision of URSKI measurements through comparison to velocities measured by an in situ acoustic Doppler velocimeter and those predicted by a standard swell model, and we evaluated how the dimensions of the devices, its buoyancy, and sampling frequency can be modified for use in a variety of environments.

  8. Polarization phenomena in deuteron proton scattering: a useful tool for the study of nucleon resonances properties

    International Nuclear Information System (INIS)

    Rekalo, M.P.; Tomasi-Gustafsson, E.

    1996-01-01

    The microscopic structure of the nucleon N and its excited states N* can be determined through the (elastic or inelastic) electromagnetic form factors. These form factors should help to understand the nature of the transition regime from soft physics of the confinement region to the hard physics of the perturbative QCD. The authors show that hadron induced reactions with isospin zero projectiles, could be an effective method for the study of the nucleon structure, in particular through the measurement of polarization observables. They analyzed the properties of the inclusive d + p reactions, with particular interest in the domain of nucleonic resonances excitation. The calculated cross section and polarization observables show that it is possible to disentangle the different reaction mechanisms (omega, sigma and eta exchange) and bring new information about the electromagnetic form factors of the deuteron as well as of the nucleonic resonances. Existing data on the tensor analyzing power are in agreement with the prediction based on the omega exchange model. (authors)

  9. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  10. Instrument for the measuring magnetic field characteristics of induction acceleration

    International Nuclear Information System (INIS)

    Novikov, V.M.; Romasheva, P.I.

    1976-01-01

    An instrument for the measuring instantaneous values of variable and pulsed magnetic fields with an amplitide of 0.005-2.0 and duration of 5x10 -6 -2x10 -2 sec is described. Time resolution is not less than 0.5 musec, measuring accuracy is about 1%. Induction coils are used as sensors. A digital voltmeter serves as a secondary recorder

  11. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  12. High-order Two-Fluid Plasma Solver for Direct Numerical Simulations of Magnetic Flows with Realistic Transport Phenomena

    Science.gov (United States)

    Li, Zhaorui; Livescu, Daniel

    2017-11-01

    The two-fluid plasma equations with full transport terms, including temperature and magnetic field dependent ion and electron viscous stresses and heat fluxes, frictional drag force, and ohmic heating term have been solved by using the sixth-order non-dissipative compact scheme for plasma flows in several different regimes. In order to be able to fully resolve all the dynamically relevant time and length scales while maintaining computational feasibility, the assumptions of infinite speed of light and negligible electron inertia have been made. The accuracy and robustness of this two-fluid plasma solver in handling plasma flows have been tested against a series of canonical problems, such as Alfven-Whistler dispersion relation, electromagnetic plasma shock, magnetic reconnection, etc. For all test cases, grid convergence tests have been conducted to achieve fully resolved results. The roles of heat flux, viscosity, resistivity, Hall and Biermann battery effects, are investigated for the canonical flows studied.

  13. Solar Spectral Lines with Special Polarization Properties for the Calibration of Instrument Polarization

    Energy Technology Data Exchange (ETDEWEB)

    Li, W.; Casini, R.; Alemán, T. del Pino; Judge, P. G. [High Altitude Observatory, National Center for Atmospheric Research 1, P.O. Box 3000, Boulder, CO 80307-3000 (United States)

    2017-10-20

    We investigate atomic transitions that have previously been identified as having zero polarization from the Zeeman effect. Our goal is to identify spectral lines that can be used for the calibration of instrumental polarization of large astronomical and solar telescopes, such as the Daniel K. Inouye Solar Telescope, which is currently under construction on Haleakala. We use a numerical model that takes into account the generation of scattering polarization and its modification by the presence of a magnetic field of arbitrary strength. We adopt values for the Landé factors from spectroscopic measurements or semi-empirical results, thus relaxing the common assumption of LS-coupling previously used in the literature. The mechanisms dominating the polarization of particular transitions are identified, and we summarize groups of various spectral lines useful for the calibration of spectropolarimetric instruments, classified according to their polarization properties.

  14. Satisfaction measurement instruments for healthcare service users: a systematic review

    OpenAIRE

    Almeida, Renato Santos de; Bourliataux-Lajoinie, Stephane; Martins, Mônica

    2015-01-01

    Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND...

  15. Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument

    Science.gov (United States)

    Singh, Manmohan; Han, Zhaolong; Nair, Achuth; Schill, Alexander; Twa, Michael D.; Larin, Kirill V.

    2017-02-01

    Current clinical tools provide critical information about ocular health such as intraocular pressure (IOP). However, they lack the ability to quantify tissue material properties, which are potent markers for ocular tissue health and integrity. We describe a single instrument to measure the eye-globe IOP, quantify corneal biomechanical properties, and measure corneal geometry with a technique termed applanation optical coherence elastography (Appl-OCE). An ultrafast OCT system enabled visualization of corneal dynamics during noncontact applanation tonometry and direct measurement of micro air-pulse induced elastic wave propagation. Our preliminary results show that the proposed Appl-OCE system can be used to quantify IOP, corneal biomechanical properties, and corneal geometry, which builds a solid foundation for a unique device that can provide a more complete picture of ocular health.

  16. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  17. Virtual Instrument for Emissions Measurement of Internal Combustion Engines

    Science.gov (United States)

    Pérez, Armando; Montero, Gisela; Coronado, Marcos; García, Conrado; Pérez, Rubén

    2016-01-01

    The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was developed to measure the combustion emissions from an internal combustion diesel engine, running with diesel-biodiesel mixtures. This software is called virtual instrument for emissions measurement (VIEM), and it was developed in the platform of LabVIEW 2010® virtual programming. VIEM works with sensors connected to a signal conditioning system, and a data acquisition system is used as interface for a computer in order to measure and monitor in real time the emissions of O2, NO, CO, SO2, and CO2 gases. This paper shows the results of the VIEM programming, the integrated circuits diagrams used for the signal conditioning of sensors, and the sensors characterization of O2, NO, CO, SO2, and CO2. VIEM is a low-cost instrument and is simple and easy to use. Besides, it is scalable, making it flexible and defined by the user. PMID:27034893

  18. Virtual Instrument for Emissions Measurement of Internal Combustion Engines.

    Science.gov (United States)

    Pérez, Armando; Ramos, Rogelio; Montero, Gisela; Coronado, Marcos; García, Conrado; Pérez, Rubén

    2016-01-01

    The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was developed to measure the combustion emissions from an internal combustion diesel engine, running with diesel-biodiesel mixtures. This software is called virtual instrument for emissions measurement (VIEM), and it was developed in the platform of LabVIEW 2010® virtual programming. VIEM works with sensors connected to a signal conditioning system, and a data acquisition system is used as interface for a computer in order to measure and monitor in real time the emissions of O2, NO, CO, SO2, and CO2 gases. This paper shows the results of the VIEM programming, the integrated circuits diagrams used for the signal conditioning of sensors, and the sensors characterization of O2, NO, CO, SO2, and CO2. VIEM is a low-cost instrument and is simple and easy to use. Besides, it is scalable, making it flexible and defined by the user.

  19. Measurement properties of asthma-specific quality-of-life measures: protocol for a systematic review.

    Science.gov (United States)

    Apfelbacher, Christian; Paudyal, Priya; Bülbül, Alpaslan; Smith, Helen

    2014-07-24

    Asthma is a frequent chronic inflammatory disease of the airways, and the assessment of health-related quality of life (HrQoL) is important in both research and routine care. Various asthma-specific measures of HrQoL exist but there is uncertainty which measures are best suited for use in research and routine care. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measures that were developed to measure asthma-specific quality of life. This study is a systematic review of the measurement properties of asthma-specific measures of health-related quality of life. PubMed and Embase will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing or comparing measurement properties of asthma-specific HRQL tools. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study have investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing measures of asthma-specific health-related quality of life. We also aim to derive recommendations in order to help researchers and practitioners alike in the choice of instrument. PROSPERO registration number: CRD42014010491.

  20. Explosive Evaporating Phenomena of Cryogenic Fluids by Direct Contacting Normal Temperature Fluids

    Directory of Open Access Journals (Sweden)

    T Watanabe

    2016-09-01

    Full Text Available Cryogenic fluids have characteristics such as thermal stratification and flashing by pressure release in storage vessel. The mixture of the extreme low temperature fluid and the normal temperature fluid becomes the cause which causes pressure vessel and piping system crush due to explosive boiling and rapid freezing. In recent years in Japan, the demand of cryogenic fluids like a LH2, LNG is increasing because of the advance of fuel cell device technology, hydrogen of engine, and stream of consciousness for environmental agreement. These fuel liquids are cryogenic fluids. On the other hand, as for fisheries as well, the use of a source of energy that environment load is small has been being a pressing need. And, the need of the ice is high, as before, for keeping freshness of marine products in fisheries. Therefore, we carried out the experiments related to promotion of evaporating cryogenic fluids and generation of ice, in the contact directly of the water and liquid nitrogen. From the results of visualization, phenomena of explosive evaporating and ice forming were observed by using video camera.

  1. D-Catch instrument : development and psychometric testing of a measurement instrument for nursing documentation in hospitals

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees P.

    AIM: This paper is a report of the development and testing of the psychometric properties of an instrument to measure the accuracy of nursing documentation in general hospitals. BACKGROUND: Little information is available about the accuracy of nursing documentation. None of the existing instruments

  2. Computer program for calculating thermodynamic and transport properties of fluids

    Science.gov (United States)

    Hendricks, R. C.; Braon, A. K.; Peller, I. C.

    1975-01-01

    Computer code has been developed to provide thermodynamic and transport properties of liquid argon, carbon dioxide, carbon monoxide, fluorine, helium, methane, neon, nitrogen, oxygen, and parahydrogen. Equation of state and transport coefficients are updated and other fluids added as new material becomes available.

  3. A digital, constant-frequency pulsed phase-locked-loop instrument for real-time, absolute ultrasonic phase measurements

    Science.gov (United States)

    Haldren, H. A.; Perey, D. F.; Yost, W. T.; Cramer, K. E.; Gupta, M. C.

    2018-05-01

    A digitally controlled instrument for conducting single-frequency and swept-frequency ultrasonic phase measurements has been developed based on a constant-frequency pulsed phase-locked-loop (CFPPLL) design. This instrument uses a pair of direct digital synthesizers to generate an ultrasonically transceived tone-burst and an internal reference wave for phase comparison. Real-time, constant-frequency phase tracking in an interrogated specimen is possible with a resolution of 0.000 38 rad (0.022°), and swept-frequency phase measurements can be obtained. Using phase measurements, an absolute thickness in borosilicate glass is presented to show the instrument's efficacy, and these results are compared to conventional ultrasonic pulse-echo time-of-flight (ToF) measurements. The newly developed instrument predicted the thickness with a mean error of -0.04 μm and a standard deviation of error of 1.35 μm. Additionally, the CFPPLL instrument shows a lower measured phase error in the absence of changing temperature and couplant thickness than high-resolution cross-correlation ToF measurements at a similar signal-to-noise ratio. By showing higher accuracy and precision than conventional pulse-echo ToF measurements and lower phase errors than cross-correlation ToF measurements, the new digitally controlled CFPPLL instrument provides high-resolution absolute ultrasonic velocity or path-length measurements in solids or liquids, as well as tracking of material property changes with high sensitivity. The ability to obtain absolute phase measurements allows for many new applications than possible with previous ultrasonic pulsed phase-locked loop instruments. In addition to improved resolution, swept-frequency phase measurements add useful capability in measuring properties of layered structures, such as bonded joints, or materials which exhibit non-linear frequency-dependent behavior, such as dispersive media.

  4. Calibration Base Lines for Electronic Distance Measuring Instruments (EDMI)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A calibration base line (CBL) is a precisely measured, straight-line course of approximately 1,400 m used to calibrate Electronic Distance Measuring Instruments...

  5. Model for the radionuclide measurement of ascitic fluid volumes

    International Nuclear Information System (INIS)

    Kaplan, W.D.; Davis, M.A.; Uren, R.F.; Wisotsky, T.; LaTegola, M.

    1978-01-01

    Technetium-99m phytate colloids formed in vitro and in vivo were examined as radioindicators for estimation of the volume of third-space fluid in an ovarian ascites model using C3HeB/FeJ mice. In double-label experiments, the accuracy of the colloids for dilution analysis was found to be equal or superior to that of I-125 HSA. Sampling times 3 to 5 min after intraperitoneal administration were found to produce the best volume estimates. Four needle-stopcock assemblies inserted sequentially into the quadrants of the peritoneal cavity were used for administration and sampling of the radioindicators. The stopcocks could be closed to prevent leakage of ascitic fluid during the procedure. In contrast to radiolabeled albumin, Tc-99m phytate colloids have clinical use for simultaneous imaging of radiotracer migration to assess potential occlusion of diaphragmatic lymphatics by neoplastic cells, and for dilution analysis to estimate volume of ascitic fluid

  6. Development Of An Experiment For Measuring Flow Phenomena Occurring In A Lower Plenum For VHTR CFD Assessment

    Energy Technology Data Exchange (ETDEWEB)

    D. M. McEligot; K.G. Condie; G. E. Mc Creery; H. M. Mc Ilroy

    2005-09-01

    The objective of the present report is to document the design of our first experiment to measure generic flow phenomena expected to occur in the lower plenum of a typical prismatic VHTR (Very High Temperature Reactor) concept. In the process, fabrication sketches are provided for the use of CFD (computational fluid dynamics) analysts wishing to employ the data for assessment of their proposed codes. The general approach of the project is to develop new benchmark experiments for assessment in parallel with CFD and coupled CFD/systems code calculations for the same geometry. One aspect of the complex flow in a prismatic VHTR is being addressed: flow and thermal mixing in the lower plenum ("hot streaking" issue). Current prismatic VHTR concepts were examined to identify their proposed flow conditions and geometries over the range from normal operation to decay heat removal in a pressurized cooldown. Approximate analyses were applied to determine key non-dimensional parameters and their magnitudes over this operating range. The flow in the lower plenum can locally be considered to be a situation of multiple jets into a confined crossflow -- with obstructions. Flow is expected to be turbulent with momentum-dominated turbulent jets entering; buoyancy influences are estimated to be negligible in normal full power operation. Experiments are needed for the combined features of the lower plenum flows. Missing from the typical jet experiments available are interactions with nearby circular posts and with vertical posts in the vicinity of vertical walls - with near stagnant surroundings at one extreme and significant crossflow at the other.

  7. Measurement and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, Harold

    2018-01-02

    This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

  8. Nondestructive assay instrument for measurement of plutonium in solutions

    International Nuclear Information System (INIS)

    Shirk, D.G.; Hsue, F.; Li, T.K.; Canada, T.R.

    1979-01-01

    A nondestructive assay (NDA) instrument that measures the 239 Pu content in solutions, using a passive gamma-ray spectroscopy technique, has been developed and installed in the LASL Plutonium Processing Facility. A detailed evaluation of this instrument has been performed. The results show that the instrument can routinely determine 239 Pu concentrations of 1 to 500 g/l with accuracies of 1 to 5% and assay times of 1 to 2 x 10 3 s

  9. Thermodynamic properties of cryogenic fluids

    CERN Document Server

    Leachman, Jacob; Lemmon, Eric; Penoncello, Steven

    2017-01-01

    This update to a classic reference text provides practising engineers and scientists with accurate thermophysical property data for cryogenic fluids. The equations for fifteen important cryogenic fluids are presented in a basic format, accompanied by pressure-enthalpy and temperature-entropy charts and tables of thermodynamic properties. It begins with a chapter introducing the thermodynamic relations and functional forms for equations of state, and goes on to describe the requirements for thermodynamic property formulations, needed for the complete definition of the thermodynamic properties of a fluid. The core of the book comprises extensive data tables and charts for the most commonly-encountered cryogenic fluids. This new edition sees significant updates to the data presented for air, argon, carbon monoxide, deuterium, ethane, helium, hydrogen, krypton, nitrogen and xenon. The book supports and complements NIST’s REFPROP - an interactive database and tool for the calculation of thermodynamic propertie...

  10. Optoelectronic instrumentation enhancement using data mining feedback for a 3D measurement system

    Science.gov (United States)

    Flores-Fuentes, Wendy; Sergiyenko, Oleg; Gonzalez-Navarro, Félix F.; Rivas-López, Moisés; Hernandez-Balbuena, Daniel; Rodríguez-Quiñonez, Julio C.; Tyrsa, Vera; Lindner, Lars

    2016-12-01

    3D measurement by a cyber-physical system based on optoelectronic scanning instrumentation has been enhanced by outliers and regression data mining feedback. The prototype has applications in (1) industrial manufacturing systems that include: robotic machinery, embedded vision, and motion control, (2) health care systems for measurement scanning, and (3) infrastructure by providing structural health monitoring. This paper presents new research performed in data processing of a 3D measurement vision sensing database. Outliers from multivariate data have been detected and removal to improve artificial intelligence regression algorithm results. Physical measurement error regression data has been used for 3D measurements error correction. Concluding, that the joint of physical phenomena, measurement and computation is an effectiveness action for feedback loops in the control of industrial, medical and civil tasks.

  11. Procedure for measuring simultaneously the solar and visible properties of glazing with complex internal or external structures.

    Science.gov (United States)

    Gentle, A R; Smith, G B

    2014-10-20

    Accurate solar and visual transmittances of materials in which surfaces or internal structures are complex are often not easily amenable to standard procedures with laboratory-based spectrophotometers and integrating spheres. Localized "hot spots" of intensity are common in such materials, so data on small samples is unreliable. A novel device and simple protocols have been developed and undergone validation testing. Simultaneous solar and visible transmittance and reflectance data have been acquired for skylight components and multilayer polycarbonate roof panels. The pyranometer and lux sensor setups also directly yield "light coolness" in lumens/watt. Sample areas must be large, and, although mainly in sheet form, some testing has been done on curved panels. The instrument, its operation, and the simple calculations used are described. Results on a subset of diffuse and partially diffuse materials with no hot spots have been cross checked using 150 mm integrating spheres with a spectrophotometer and the Air Mass 1.5 spectrum. Indications are that results are as good or better than with such spheres for transmittance, but reflectance techniques need refinement for some sample types.

  12. A Secure System Architecture for Measuring Instruments in Legal Metrology

    Directory of Open Access Journals (Sweden)

    Daniel Peters

    2015-03-01

    Full Text Available Embedded systems show the tendency of becoming more and more connected. This fact combined with the trend towards the Internet of Things, from which measuring instruments are not immune (e.g., smart meters, lets one assume that security in measuring instruments will inevitably play an important role soon. Additionally, measuring instruments have adopted general-purpose operating systems to offer the user a broader functionality that is not necessarily restricted towards measurement alone. In this paper, a flexible software system architecture is presented that addresses these challenges within the framework of essential requirements laid down in the Measuring Instruments Directive of the European Union. This system architecture tries to eliminate the risks general-purpose operating systems have by wrapping them, together with dedicated applications, in secure sandboxes, while supervising the communication between the essential parts and the outside world.

  13. Instrumentation for electromagnetic field generation in biological measurements

    International Nuclear Information System (INIS)

    Malaric, K.; Malaric, R.; Tkalec, M.; Lenicek, I.; Sala, A.

    2005-01-01

    Electromagnetic fields (EMFs) are part of everyday life in modern world. Extremely low-frequency EMFs (50 Hz) are produced by most electric home appliance, electric power transmission and distribution lines. For the last ten years mobile phones have been widely used all around the world. They operate on the EMF frequencies from 400 MHz to 1900 MHz. The effects of EMFs on living organisms have been the subject of debate and research for the last thirty years. The instrumentation for generation of EMFs have been designed at the Faculty of Electrical Engineering and Computing, Zagreb, and can be used for controlled exposure to different EMFs. To study the effect of extremely low-frequency EMF, duckweed (Lemna minor) - the model plant in biological measurement, test setup was made for magnetic field in Helmholtz coil and for electric field between two parallel circle electrodes. For the effect of mobile phones frequencies, test setup with exposition to the electromagnetic field was done with Gigahertz Transversal Electromagnetic Mode (GTEM) cell. The research confirmed that instrumentation used in these experiments is suitable for evaluation of biological effects of EMFs. The effect of different field strengths, exposure times and modulation can be tested with these instrumentation.(author)

  14. Seed drill instrumentation for spatial coulter depth measurements

    DEFF Research Database (Denmark)

    Kirkegaard Nielsen, Søren; Munkholm, Lars Juhl; Lamandé, Mathieu

    2017-01-01

    coulter depth varied up to ±5 mm between the blocks. In addition, significant depth variations between the individual coulters were found. The mean depths varied between −14.2 and −25.9 mm for the eleven coulters. The mean shallowest coulter depth (−14.2 mm) was measured for the coulter running...... in the wheel track of the tractor. The power spectral densities (distribution) of the coulter depth oscillation frequencies showed that the majority of oscillations occurred below 0.5 Hz without any natural vibration frequency. The study concluded that the instrumentation concept was functional for on...

  15. [Psychometric properties of an instrument for assessing cyber-sex addiction].

    Science.gov (United States)

    Ballester Arnal, Rafael; Gil Llario, Ma Dolores; Gómez Martínez, Sandra; Gil Juliá, Beatriz

    2010-11-01

    Psychometric properties of an instrument for assessing cyber-sex addiction. Cyber-sex addiction is a «new pathology» whose prevalence has grown rapidly in recent years. Therefore, it is important to have validated assessment instruments. The aim of this study was the adaptation and validation of the Internet Sex Screening Test (ISST) for its use in a Spanish population. The instrument was administered to 1239 Spanish college students. The results yielded five components that account for 47.5% of the variance. Internal consistency was .88 and temporal stability was .84. Moreover, the instrument had adequate convergent and discriminant validity and was related to other behaviors such as the use of pornography, internet addiction, number of hours online and sexual frequency. Therefore, this tool is proposed as an appropriate measure to assess cyber-sex addiction.

  16. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  17. Electron impact phenomena and the properties of gaseous ions

    CERN Document Server

    Field, F H; Massey, H S W; Brueckner, Keith A

    1970-01-01

    Electron Impact Phenomena and the Properties of Gaseous Ions, Revised Edition deals with data pertaining to electron impact and to molecular gaseous ionic phenomena. This book discusses electron impact phenomena in gases at low pressure that involve low-energy electrons, which result in ion formation. The text also describes the use of mass spectrometers in electron impact studies and the degree of accuracy obtained when measuring electron impact energies. This book also reviews relatively low speed electrons and the transitions that result in the ionization of the atomic system. This text the

  18. Process and device for cooling liquid or vaporised fluids

    International Nuclear Information System (INIS)

    1975-01-01

    The invention relates to a process for the ambient air cooling of liquid fluids or those vaporised under low pressure. An exchanger composing a first circuit for the fluid to be cooled is set up and is separated by a partition from a second circuit swept by the atmospheric air. Each one of these two circuits is made up of pipes of not more than 4 mm hydraulic diameter and on the side of the second circuit swept by the air a quantity of water is brought to the extent of 0 to 50 g/kg of dry air crossing it. The water is sprayed into the second circuit. The tubes of the second circuit are set up so that the water sprayed on, runs down the partition separating the two circuits. The water is sprayed counter-current with respect to the direction of the cooling air. A quantity of water is projected into the second circuit depending on the thermal flow to be exchanged and the desired cooling temperature, the amount of water being limited so that the outgoing air, returned to the atmosphere, contains an amount of water per kilogram of dry air corresponding to the absolute moisture of the saturated air for the dry ambient temperature at the time. The process affords all the advantages of a wet cooling tower, great efficiency and low temperature [fr

  19. Measurement properties of instruments evaluating self-care and related concepts in people with chronic obstructive pulmonary disease: A systematic review.

    Science.gov (United States)

    Clari, Marco; Matarese, Maria; Alvaro, Rosaria; Piredda, Michela; De Marinis, Maria Grazia

    2016-01-01

    The use of valid and reliable instruments for assessing self-care is crucial for the evaluation of chronic obstructive pulmonary disease (COPD) management programs. The aim of this review is to evaluate the measurement properties and theoretical foundations of instruments for assessing self-care and related concepts in people with COPD. A systematic review was conducted of articles describing the development and validation of self-care instruments. The methodological quality of the measurement properties was assessed using the COSMIN checklist. Ten studies were included evaluating five instruments: three for assessing self-care and self-management and two for assessing self-efficacy. The COPD Self-Efficacy Scale was the most studied instrument, but due to poor study methodological quality, evidence about its measurement properties is inconclusive. Evidence from the COPD Self-Management Scale is more promising, but only one study tested its properties. Due to inconclusive evidence of their measurement properties, no instrument can be recommended for clinical use. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. FluidCam 1&2 - UAV-based Fluid Lensing Instruments for High-Resolution 3D Subaqueous Imaging and Automated Remote Biosphere Assessment of Reef Ecosystems

    Science.gov (United States)

    Chirayath, V.; Instrella, R.

    2016-02-01

    We present NASA ESTO FluidCam 1 & 2, Visible and NIR Fluid-Lensing-enabled imaging payloads for Unmanned Aerial Vehicles (UAVs). Developed as part of a focused 2014 earth science technology grant, FluidCam 1&2 are Fluid-Lensing-based computational optical imagers designed for automated 3D mapping and remote sensing of underwater coastal targets from airborne platforms. Fluid Lensing has been used to map underwater reefs in 3D in American Samoa and Hamelin Pool, Australia from UAV platforms at sub-cm scale, which has proven a valuable tool in modern marine research for marine biosphere assessment and conservation. We share FluidCam 1&2 instrument validation and testing results as well as preliminary processed data from field campaigns. Petabyte-scale aerial survey efforts using Fluid Lensing to image at-risk reefs demonstrate broad applicability to large-scale automated species identification, morphology studies and reef ecosystem characterization for shallow marine environments and terrestrial biospheres, of crucial importance to improving bathymetry data for physical oceanographic models and understanding climate change's impact on coastal zones, global oxygen production, carbon sequestration.

  1. A magnetorheological fluid-based multifunctional haptic device for vehicular instrument controls

    International Nuclear Information System (INIS)

    Han, Young-Min; Kim, Chan-Jung; Choi, Seung-Bok

    2009-01-01

    This paper presents control performances of a magnetorheological (MR) fluid-based multifunctional haptic device which is applicable to vehicular instrument controls. By combining in-vehicle functions into a single device, the proposed haptic device can transmit various reflection forces for each comfort function to a driver without requiring the driver's visual attention. As a multifunctional haptic device, a MR knob is proposed in this work and then devised to be capable of both rotary and push motions with a single knob. Under consideration of the spatial limitations of vehicle dashboards, design parameters are optimally determined by finite element analysis, and the objective function is to maximize a relative control torque. The proposed haptic device is then manufactured, and in-vehicle comfort functions are constructed in a virtual environment which makes the functions to communicate with the haptic device. Subsequently, a feed-forward controller using torque/force maps is formulated for the force tracking control. Control performances such as reflection force of the haptic device are experimentally evaluated via the torque/force map-based feed-forward controller

  2. Integrated, Multi-Scale Characterization of Imbibition and Wettability Phenomena Using Magnetic Resonance and Wide-Band Dielectric Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mukul M. Sharma; Steven L. Bryant; Carlos Torres-Verdin; George Hirasaki

    2007-09-30

    The petrophysical properties of rocks, particularly their relative permeability and wettability, strongly influence the efficiency and the time-scale of all hydrocarbon recovery processes. However, the quantitative relationships needed to account for the influence of wettability and pore structure on multi-phase flow are not yet available, largely due to the complexity of the phenomena controlling wettability and the difficulty of characterizing rock properties at the relevant length scales. This project brings together several advanced technologies to characterize pore structure and wettability. Grain-scale models are developed that help to better interpret the electric and dielectric response of rocks. These studies allow the computation of realistic configurations of two immiscible fluids as a function of wettability and geologic characteristics. These fluid configurations form a basis for predicting and explaining macroscopic behavior, including the relationship between relative permeability, wettability and laboratory and wireline log measurements of NMR and dielectric response. Dielectric and NMR measurements have been made show that the response of the rocks depends on the wetting and flow properties of the rock. The theoretical models can be used for a better interpretation and inversion of standard well logs to obtain accurate and reliable estimates of fluid saturation and of their producibility. The ultimate benefit of this combined theoretical/empirical approach for reservoir characterization is that rather than reproducing the behavior of any particular sample or set of samples, it can explain and predict trends in behavior that can be applied at a range of length scales, including correlation with wireline logs, seismic, and geologic units and strata. This approach can substantially enhance wireline log interpretation for reservoir characterization and provide better descriptions, at several scales, of crucial reservoir flow properties that govern oil

  3. Modelling of Mass Transfer Phenomena in Chemical and Biochemical Reactor Systems using Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Larsson, Hilde Kristina

    the velocity and pressure distributions in a fluid. CFD also enables the modelling of several fluids simultaneously, e.g. gas bubbles in a liquid, as well as the presence of turbulence and dissolved chemicals in a fluid, and many other phenomena. This makes CFD an appreciated tool for studying flow structures......, mixing, and other mass transfer phenomena in chemical and biochemical reactor systems. In this project, four selected case studies are investigated in order to explore the capabilities of CFD. The selected cases are a 1 ml stirred microbioreactor, an 8 ml magnetically stirred reactor, a Rushton impeller...... and an ion-exchange reaction are also modelled and compared to experimental data. The thesis includes a comprehensive overview of the fundamentals behind a CFD software, as well as a more detailed review of the fluid dynamic phenomena investigated in this project. The momentum and continuity equations...

  4. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  5. Metrological Array of Cyber-Physical Systems. Part 7. Additive Error Correction for Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yuriy YATSUK

    2015-06-01

    Full Text Available Since during design it is impossible to use the uncertainty approach because the measurement results are still absent and as noted the error approach that can be successfully applied taking as true the nominal value of instruments transformation function. Limiting possibilities of additive error correction of measuring instruments for Cyber-Physical Systems are studied basing on general and special methods of measurement. Principles of measuring circuit maximal symmetry and its minimal reconfiguration are proposed for measurement or/and calibration. It is theoretically justified for the variety of correction methods that minimum additive error of measuring instruments exists under considering the real equivalent parameters of input electronic switches. Terms of self-calibrating and verification the measuring instruments in place are studied.

  6. PHYSICO-CHEMICAL PHENOMENA IN SOIL STABILIZATION FOR ROADS OR HIGHWAYS INFRASTRUCTURES

    Directory of Open Access Journals (Sweden)

    Anghel STANCIU

    2013-11-01

    Full Text Available Reducing the impact on the environment of constructing transportation infrastructures can be achieved through reusing or recycling certain materials. In this context, the current trend is to use materials that do not have a negative impact on the environment and provide a long term solution. Such local materials for the construction of transportation infrastructure are the active clays. This paper presents the physicochemical and mineralogical structure of clays and their behavior regarding the interaction with water. A negative effect of this interaction is the swelling, the contraction and, respectively, the swell pressure. These produce effects (fissures, cracks in the structure of roads, highways and, respectively, airport runways. The authors analyze the possibility to reduce these effects by clay stabilization with mineral binders (cement, lime. Results on lime mixtures testing are presented in terms of physical and mechanical properties, and optimum percentages of the mixtures are presented. It is also concluded that this solution is more cost-effective than the classical one as replacing the clay layer from the roadbed with other filling materials transported from other areas.

  7. Piezosurgery or conventional rotatory instruments for inferior third molar extractions?

    Science.gov (United States)

    Piersanti, Luigi; Dilorenzo, Matteo; Monaco, Giuseppe; Marchetti, Claudio

    2014-09-01

    The purpose of this study was to compare the discomfort and surgical outcomes of a piezosurgery device with those of rotatory instruments in lower third molar extraction. A split-mouth, randomized, unblinded clinical study was designed; the 2 molars had to have the same extraction difficulty score. The test side was extracted using a piezosurgery technique and the control side was extracted using a conventional handpiece. The primary endpoint was patient discomfort evaluated with the Postoperative Symptom Severity (PoSSe) scale, which was administered to each patient; secondary endpoints were pain, trismus, swelling, and surgical time evaluation. Paired-samples t test and repeated-measures analysis of variance were used to compare outcomes within patients. Ten consecutive patients (6 female, 4 male; mean age, 22.4 ± 2.3 yr) were recruited. The total score on the PoSSe scale was significantly lower for piezosurgery compared with the conventional rotating handpiece (24.7 ± 10.3 vs 36.0 ± 7.6; t = -4.27; P = .002). Moreover, postoperative swelling 1 week after surgery was significantly lower for piezosurgery than for the conventional rotating handpiece (2.75 ± 0.23 vs 3.1 ± 0.39 cm; t = -2.63; P = .027). Piezosurgery was associated with less postoperative discomfort and yielded better results for swelling. Piezosurgery seems to be a good technique in daily surgical practice, especially if applied in the critical steps in which safety and respect for soft tissue, bone, and nerves are necessary. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery.

    Science.gov (United States)

    Aglzim, El-Hassane; Rouane, Amar; El-Moznine, Reddad

    2007-10-17

    In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee ® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice ® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper).The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5V)and with two imposed currents (0.6A and 4A). The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical) enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  9. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    Directory of Open Access Journals (Sweden)

    Reddad El-Moznine

    2007-10-01

    Full Text Available In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper.The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5Vand with two imposed currents (0.6A and 4A. The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  10. [Psychometric properties of Q-DIO, an instrument to measure the quality of documented nursing diagnoses, interventions and outcomes].

    NARCIS (Netherlands)

    Muller-Staub, M.; Lunney, M.; Lavin, M.A.; Needham, I.; Odenbreit, M.; Achterberg, T. van

    2010-01-01

    The instrument Q-DIO was developed in the years 2005 till 2006 to measure the quality of documented nursing diagnoses, interventions, and nursing sensitive patient outcomes. Testing psychometric properties of the Q-DIO (Quality of nursing Diagnoses, Interventions and Outcomes.) was the study aim.

  11. Variability of standard artificial soils: Physico-chemical properties and phenanthrene desorption measured by means of supercritical fluid extraction

    International Nuclear Information System (INIS)

    Bielská, Lucie; Hovorková, Ivana; Komprdová, Klára; Hofman, Jakub

    2012-01-01

    The study is focused on artificial soil which is supposed to be a standardized “soil like” medium. We compared physico-chemical properties and extractability of Phenanthrene from 25 artificial soils prepared according to OECD standardized procedures at different laboratories. A substantial range of soil properties was found, also for parameters which should be standardized because they have an important influence on the bioavailability of pollutants (e.g. total organic carbon ranged from 1.4 to 6.1%). The extractability of Phe was measured by supercritical fluid extraction (SFE) at harsh and mild conditions. Highly variable Phe extractability from different soils (3–89%) was observed. The extractability was strongly related (R 2 = 0.87) to total organic carbon content, 0.1–2 mm particle size, and humic/fulvic acid ratio in the following multiple regression model: SFE (%) = 1.35 * sand (%) − 0.77 * TOC (%)2 + 0.27 * HA/FA. - Highlights: ► We compared properties and extractability of Phe from 25 different artificial soils. ► Substantial range of soil properties was found, also for important parameters. ► Phe extractability was measured by supercritical fluid extraction (SFE) at 2 modes. ► Phe extractability was highly variable from different soils (3–89%). ► Extractability was strongly related to TOC, 0.1–2 mm particles, and HA/FA. - Significant variability in physico-chemical properties exists between artificial soils prepared at different laboratories and affects behavior of contaminants in these soils.

  12. Development of a three-dimensional PIV measurement technique for the experimental study of air bubble collapse phenomena

    International Nuclear Information System (INIS)

    Yang, Y.H.; Hassan, Y.A.; Schmidl, W.D.

    1995-01-01

    Particle image velocimetry (PIV) is a quantitative flow measurement technique. The objective of this study is to develop a new three-dimensional PIV technique for the experimental study of air bubble collapse phenomena. A three-dimensional measurement technique is necessary since bubble collapse is a three-dimensional phenomenon. The investigation of the velocity flow field around a collapsing air bubble can provide detailed three-dimensional quantitative information to help improve the understanding of the related heat transfer processes

  13. Analysis and Testing of Chain Characteristics and Rheological Properties for Magnetorheological Fluid

    Directory of Open Access Journals (Sweden)

    Song Chen

    2013-01-01

    Full Text Available Digital holographic microscopy is presented in this study, which can measure the magnetorheological (MR fluid in different volume fractions of particles and different magnetic field strengths. Based on the chain structure of magnetic particle under applied magnetic field, the relationships between shear yield stress, magnetic field, size, and volume fraction of MR fluid in two parallel discs are established. In this experiment, we choose three MR fluid samples to check the rheological properties of MR fluid and to obtain the material parameters with the test equipment of MR fluid; the conclusion is effective.

  14. Instrumentation for Structure Measurements on Highly Non-equilibrium Materials

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Richard [Argonne National Laboratory (ANL); Benmore, Chris J [Argonne National Laboratory (ANL); Neuefeind, Joerg C [ORNL; Wilding, Martin C [ORNL

    2011-01-01

    Containerless techniques (levitation) completely eliminate contact with the sample. This unique sample environment allows deep supercooling of many liquids and avoids contamination of high temperature melts. Recent experiments at the APS high energy beamline 11 ID-C used aerodynamic levitation with laser beam heating and acoustic levitation with cryogenic cooling. By using these two methods, liquids were studied over much of the temperature range from -40 to +2500 C. This paper briefly describes the instrumentation and its use with an -Si area detector that allows fast, in-situ measurements. Use of the instruments is illustrated with examples of measurements on molten oxides and aqueous materials.

  15. Instrument for benzene and toluene emission measurements of glycol regenerators

    International Nuclear Information System (INIS)

    Hanyecz, Veronika; Szabó, Gábor; Mohácsi, Árpád; Puskás, Sándor; Vágó, Árpád

    2013-01-01

    We introduce an in-field and in-explosive atmosphere useable instrument, which can measure the benzene and toluene concentration in two gas and two glycol samples produced by natural gas dehydration units. It is a two-phase, on-line gas chromatograph with a photoacoustic spectroscopy based detector. The time resolution is 10 min per cycle and the minimum detectable concentrations are 2 mg m −3 for benzene, 3 mg m −3 for toluene in natural gas, and 5 g m −3 for benzene and 6 g m −3 for toluene in glycol. Test measurements were carried out at a dehydration plant belonging to MOL Hungarian Oil and Gas Company. Benzene and toluene emissions of gas dehydration unit are calculated from the measured values based on mass balance of a glycol regenerator. The relationship between the outdoor temperature and the measured concentration was observed which is caused by temperature-dependent operation of the whole dehydration unit. Emission decreases with increase of outdoor temperature. (paper)

  16. Experience of the use of radiation measuring instruments for Russia

    International Nuclear Information System (INIS)

    Matsubara, S.; Ohshima, T.; Kawaguti, H.

    1994-01-01

    After the Chernobyl accident, among a series of international cooperations, also from our company T.OHSHIMA visited Russia in October, 1991 as a member of the USSR and Japan Joint Specialist Meeting on Environmental Radiation and Shelter Structure of Chernobyl-4 Nuclear Power Plant, and a few members including H.KAWAGUTI visited there in December, 1991 for the handling instructions of the apparatus delivered to Sasagawa Memorial Health Cooperation Foundation. During these visits to Russia they carried electronic personal dosimeters and pocketsize dose ratemeters, measured the doses and dose rate of some areas including the actual polluted areas and gained interesting data. Especially T.OHSHIMA entered the turbine structure of Chernobyl No.4 Reactor and experienced 7m Sv/h. I introduce these measurement data and the instruments used for the measurement. Also H.KAWAGUTI and others explained the maintenance and handling of the whole body counter loaded into the medical examination car offered to Russia for Chernobyl Sasagawa Medical Care Cooperation Project of Sasagawa Memorial Health Cooperation Foundation. I introduce the outline of this medical examination car laying stress on the whole body counter and present a part of the data by the whole body counter measured during the medical care cooperation. (author)

  17. Some simple results for the properties of polar fluids

    Directory of Open Access Journals (Sweden)

    D. Henderson

    2011-09-01

    Full Text Available The author's lecture notes concerning the correlation functions and the thermodynamics of a simple polar fluid are summarized. The emphasis is on the dipolar hard sphere fluid and the mean spherical approximation and on the relation of these results to the Clausius-Mossotti and Onsager formulae for the dielectric constant. Previous excerpts from these lecture notes, Condens. Matter Phys., 2009, 12, 127; ibid., 2010, 13, 13002, have contained results that were not widely known. It is hoped that this third, and likely final, excerpt will prove equally helpful by gathering several results together and making these more widely available and recording a few new results.

  18. Measuring Lagrangian accelerations using an instrumented particle

    International Nuclear Information System (INIS)

    Zimmermann, R; Fiabane, L; Volk, R; Pinton, J-F; Gasteuil, Y

    2013-01-01

    Accessing and characterizing a flow imposes a number of constraints on the employed measurement techniques; in particular, optical methods require transparent fluids and windows in the vessel. Whereas one can adapt the apparatus, fluid and methods in the laboratory to these constraints, this is hardly possible for industrial mixers. In this paper, we present a novel measurement technique which is suitable for opaque or granular flows: consider an instrumented particle, which continuously transmits the force/acceleration acting on it as it is advected in a flow. Its density is adjustable for a wide range of fluids and because of its small size and its wireless data transmission, the system can be used both in industrial and in scientific mixers, allowing for a better understanding of the flow within. We demonstrate the capabilities and precision of the particle by comparing its transmitted acceleration to alternative measurements, in particular in the case of a turbulent von Kármán flow. Our technique proves to be an efficient and fast tool to characterize flows. (paper)

  19. Fluid Physical and Transport Phenomena Studies aboard the International Space Station: Planned Experiments

    Science.gov (United States)

    Singh, Bhim S.

    1999-01-01

    This paper provides an overview of the microgravity fluid physics and transport phenomena experiments planned for the International Spare Station. NASA's Office of Life and Microgravity Science and Applications has established a world-class research program in fluid physics and transport phenomena. This program combines the vast expertise of the world research community with NASA's unique microgravity facilities with the objectives of gaining new insight into fluid phenomena by removing the confounding effect of gravity. Due to its criticality to many terrestrial and space-based processes and phenomena, fluid physics and transport phenomena play a central role in the NASA's Microgravity Program. Through widely publicized research announcement and well established peer-reviews, the program has been able to attract a number of world-class researchers and acquired a critical mass of investigations that is now adding rapidly to this field. Currently there arc a total of 106 ground-based and 20 candidate flight principal investigators conducting research in four major thrust areas in the program: complex flows, multiphase flow and phase change, interfacial phenomena, and dynamics and instabilities. The International Space Station (ISS) to be launched in 1998, provides the microgravity research community with a unprecedented opportunity to conduct long-duration microgravity experiments which can be controlled and operated from the Principal Investigators' own laboratory. Frequent planned shuttle flights to the Station will provide opportunities to conduct many more experiments than were previously possible. NASA Lewis Research Center is in the process of designing a Fluids and Combustion Facility (FCF) to be located in the Laboratory Module of the ISS that will not only accommodate multiple users but, allow a broad range of fluid physics and transport phenomena experiments to be conducted in a cost effective manner.

  20. INSTRUMENTATION FOR MEASURING AND TRANSMISSION THE SOLAR RADIATION THROUGH EARTH’S ATMOSPHERE

    Directory of Open Access Journals (Sweden)

    Alexandru Dan Toma

    2013-07-01

    Full Text Available The Sun's energy is distributed over a broad range of the electromagnetic spectrum and Sun behaves approximately like a "blackbody" radiating at a temperature of about 5800 K with maximum output in the green-yellow part of the visible spectrum, around 500 nm. Not all solar radiation reaching the top of the atmosphere reaches Earth's surface due to a various optical phenomena in regard to solar radiation crossing the Earth’s atmosphere. In order to investigate them, there are two general categories of instruments used to measure the transmission of solar radiation through Earth's atmosphere: instruments that measure radiation from the entire sky and instruments that measure only direct solar radiation. Within each of these categories, instruments can be further subdivided into those that measure radiation over a broad range of wavelengths and those that measure only specific wavelengths.

  1. Nuclear methods applied for studies of contact phenomena in metal-fluid media and between metallic components in relative motion

    International Nuclear Information System (INIS)

    Racolta, P.M.; Popa-Simil, L.; Voiculescu, Dana; Muntele, C. I.

    1997-01-01

    The two main goals of this research project were: establishing of an activation methodology for metallic structures using accelerated beams obtained at our cyclotron and adapting the spectrometric analysis methods of the gamma radiations for corrosion level determinations. The developed methods, including the calibration (relations between the radioactivity level and the thickness of removed layer due to corrosion), were based on the remnant radioactivity measuring method. The experiments were focused on a proper selection of the nuclear reaction to be utilised for measurements, depending on the type of metallic alloys investigated. This study also consisted of optimizing the irradiation (particle, energy and dose) and cooling time so as to obtain a measuring sensitivity of 0.1-1μm for Fe, Ti, V, Cr, Cu, Mo based alloys. A portable two-channel γ-spectrometric installation was adapted to a customer's corrosion testing stand. Corrosion levels of a Romanian-made injection pump working with different types of Diesel oils and Diesel oil + special additives + water mixtures were determined. The nuclear reactions used were 56 Fe (p,n) 56 Co and 56 Fe (d,n) 57 Co. A selected area of the pump's piston was activated up to 30 μm. The testing programme was made for 300 h working times on the test stand; corrosion levels of approx. 0.3 μm were observed. In cooperation with a group from Tribology Laboratory from the Bucharest Technical University, Ti-coated pallets of a water pump were tested in their near real working environment - salty and sandy water. The 48 Ti (p,n) 48 V nuclear reaction was used for labelling a Ti thickness up to 50 μm. In this experiment, the main interest was to determine the minimum detectable corroded thickness by this radiotracer - based method. Our measurements showed that sensitivities of 0.05 - 1 μm can be achieved. In 1996, in cooperation with the National Institute for Thermal Engines, the wear of the piston ring - cylinder jacket friction

  2. Towards a measurement instrument for determinants of innovations

    NARCIS (Netherlands)

    Fleuren, M.A.H.; Paulussen, T.G.W.M.; van Dommelen, P.; van Buuren, S.

    2014-01-01

    Objective. To develop a short instrument to measure determinants of innovations that may affect its implementation. Design. We pooled the original data from eight empirical studies of the implementation of evidence-based innovations. The studies used a list of 60 potentially relevant determinants

  3. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  4. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  5. Developing a TPACK measurement instrument for 21st century pre-service teachers

    Directory of Open Access Journals (Sweden)

    Teemu Valtonen

    2015-11-01

    Full Text Available  Future skills, so-called 21st century skills, emphasise collaboration, creativity, critical thinking, problem-solving and especially ICT skills (Voogt & Roblin, 2012. Teachers have to be able to use various pedagogical approaches and ICT in order to support the development of their students’ 21st century skills (Voogt & Roblin, 2012. These skills, particularly ICT skills, pose challenges for teachers and teacher education. This paper focuses on developing an instrument for measuring pre-service teachers’ knowledge related to ICT in the context of 21st century skills.Technological Pedagogical Content Knowledge (TPACK; Mishra & Kohler, 2006 was used as a theoretical framework for designing the instrument. While the TPACK framework is actively used, the instruments used to measure it have proven challenging. This paper outlines the results of the development process of the TPACK-21 instrument. A new assessment instrument was compiled and tested on pre-service teachers in Study1 (N=94. Based on these results, the instrument was further developed and tested in Study2 (N=267. The data of both studies were analysed using multiple quantitative methods in order to evaluate the psychometric properties of the instruments. The results provide insight into the challenges of the development process itself and also suggest new solutions to overcome these difficulties.

  6. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  7. An influence of low-stability region on dense gas phenomena and their peculiarities in the ORC fluids

    Directory of Open Access Journals (Sweden)

    Matuszewska Dominika

    2014-01-01

    Full Text Available An existence of low stability region in the dense vapours and its influence on some peculiarities in behaviour of selected dry and isentropic ORC fluids is discussed. The retrograde phenomena in the flow of BZT fluids [1.] can be simply related to the mechanical and thermodynamic stability parameters. These new refrigerant and their properties have been analysed based on the software tools REFPROP v.9.1 [2.]. Test examples have confirmed an importance of low thermodynamic stability area in the vicinity of saturation boundary line and neighbourhood of critical point of the fluid. The analytical results have been obtained for selected pure fluids applicable in the ORC and heat pump technology such C4H10, C6H5CH3, C12H26, R123, R134a, R227ea, R245fa, low GWP hydrofluoroolefins (R1234xxXand a group of linear and cyclic siloxanes.

  8. Review of modern instrumentation for magnetic measurements at high pressure and low temperature

    International Nuclear Information System (INIS)

    Wang, X.; Kamenev, K.V.

    2015-01-01

    High-pressure magnetic susceptibility experiments can provide insights into the changes in magnetic behavior and electric properties which can accompany extreme compressions of material. Instrumentation plays an important role in the experimental work in this field since 1990s. Here we present a comprehensive review of the high-pressure instrumentation development for magnetic measurement from the engineering perspective in the last 20 years. Suitable nonmagnetic materials for high pressure cell are introduced initially. Then we focus on the existing cells developed for magnetic property measurement system (MPMS) SQUID magnetometer from Quantum Design (USA). Two categories of high pressure cells for this system are discussed in detail respectively. Some high pressure cells with built-in magnetic measurement system are also reviewed

  9. In core instrumentation for online nuclear heating measurements of material testing reactor

    International Nuclear Information System (INIS)

    Reynard, C.; Andre, J.; Brun, J.; Carette, M.; Janulyte, A.; Merroun, O.; Zerega, Y.; Lyoussi, A.; Bignan, G.; Chauvin, J-P.; Fourmentel, D.; Glayse, W.; Gonnier, C.; Guimbal, P.; Iracane, D.; Villard, J.-F.

    2010-01-01

    The present work focuses on nuclear heating. This work belongs to a new advanced research program called IN-CORE which means 'Instrumentation for Nuclear radiations and Calorimetry Online in REactor' between the LCP (University of Provence-CNRS) and the CEA (French Atomic Energy Commission) - Jules Horowitz Reactor (JHR) program. This program started in September 2009 and is dedicated to the conception and the design of an innovative mobile experimental device coupling several sensors and ray detectors for on line measurements of relevant physical parameters (photonic heating, neutronic flux ...) and for an accurate parametric mapping of experimental channels in the JHR Core. The work presented below is the first step of this program and concerns a brief state of the art related to measurement methods of nuclear heating phenomena in research reactor in general and MTR in particular. A special care is given to gamma heating measurements. A first part deals with numerical codes and models. The second one presents instrumentation divided into various kinds of sensor such as calorimeter measurements and gamma ionization chamber measurements. Their basic principles, characteristics such as metrological parameters, operating mode, disadvantages/advantages, ... are discussed. (author)

  10. Novel instrument for characterizing comprehensive physical properties under multi-mechanical loads and multi-physical field coupling conditions

    Science.gov (United States)

    Liu, Changyi; Zhao, Hongwei; Ma, Zhichao; Qiao, Yuansen; Hong, Kun; Ren, Zhuang; Zhang, Jianhai; Pei, Yongmao; Ren, Luquan

    2018-02-01

    Functional materials represented by ferromagnetics and ferroelectrics are widely used in advanced sensor and precision actuation due to their special characterization under coupling interactions of complex loads and external physical fields. However, the conventional devices for material characterization can only provide a limited type of loads and physical fields and cannot simulate the actual service conditions of materials. A multi-field coupling instrument for characterization has been designed and implemented to overcome this barrier and measure the comprehensive physical properties under complex service conditions. The testing forms include tension, compression, bending, torsion, and fatigue in mechanical loads, as well as different external physical fields, including electric, magnetic, and thermal fields. In order to offer a variety of information to reveal mechanical damage or deformation forms, a series of measurement methods at the microscale are integrated with the instrument including an indentation unit and in situ microimaging module. Finally, several coupling experiments which cover all the loading and measurement functions of the instrument have been implemented. The results illustrate the functions and characteristics of the instrument and then reveal the variety in mechanical and electromagnetic properties of the piezoelectric transducer ceramic, TbDyFe alloy, and carbon fiber reinforced polymer under coupling conditions.

  11. Instrumentation for Gate Current Noise Measurements on sub-100 nm MOS Transistors

    CERN Document Server

    Gaioni, L; Ratti, L; Re, V; Speziali, V; Traversi, G

    2008-01-01

    This work describes a measuring system that was developed to characterize the gate current noise performances of CMOS devices with minimum feature size in the 100 nm span. These devices play an essential role in the design of present daymixedsignal integrated circuits, because of the advantages associated with the scaling process. The reduction in the gate oxide thickness brought about by CMOS technology downscaling leads to a non-negligible gate current due to direct tunneling phenomena; this current represents a noise source which requires an accurate characterization for optimum analog design. In this paper, two instruments able to perform measurements in two different ranges of gate current values will be discussed. Some of the results of gate current noise characterization will also be presented.

  12. Computer program for computing the properties of seventeen fluids. [cryogenic liquids

    Science.gov (United States)

    Brennan, J. A.; Friend, D. G.; Arp, V. D.; Mccarty, R. D.

    1992-01-01

    The present study describes modifications and additions to the MIPROPS computer program for calculating the thermophysical properties of 17 fluids. These changes include adding new fluids, new properties, and a new interface to the program. The new program allows the user to select the input and output parameters and the units to be displayed for each parameter. Fluids added to the MIPROPS program are carbon dioxide, carbon monoxide, deuterium, helium, normal hydrogen, and xenon. The most recent modifications to the MIPROPS program are the addition of viscosity and thermal conductivity correlations for parahydrogen and the addition of the fluids normal hydrogen and xenon. The recently added interface considerably increases the program's utility.

  13. Novel fluid dynamic instrumentation for mixing studies developed at ETH Zurich and PSI

    International Nuclear Information System (INIS)

    Prasser, H.-M.; Damsohn, M.; Frey, S.; Fokken, J.

    2009-01-01

    Wire-mesh sensors primarily developed for two-phase flows are known to be useful also for mixing studies in single-phase flows. A prominent example is the boron mixing test facility ROCOM in Rossendorf. ETH Zurich and PSI have started to use wire-mesh sensors for the characterization of the turbulent mixing process in T-junctions, which have gained a considerable relevance to nuclear safety since temperature fluctuations generated by the mixing of fluids of different temperature may cause dangerous thermal loads to the wall material. In the present paper, the application of a high-resolution wire-mesh sensor for the cross-section of the flow duct, combined with a novel wall sensor is reported. The wall sensor is as well based on a conductivity measurement, while the electrodes are manufactured as conducting structures directly flush to the surface of the channel wall. This type of nonintrusive sensor is able to provide information on concentration fluctuations from the boundary layer in experiments where salt tracers are used to substitute the temperature as transport scalar. In an experimental feasibility study it was furthermore shown that both wiremesh sensors and the new wall sensor are sensitive enough to record conductivity changes that are caused by temperature fluctuations in experiments without a tracer salt. This means that benefit can be taken from of high spatial and temporal resolution of both types of sensors to study temperature fluctuations. (author)

  14. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  15. An instrument for measurement of 125I with automatic efficiency correction

    International Nuclear Information System (INIS)

    Holford, R.M.

    1979-10-01

    Counting efficiencies for 125 I are often uncertain because of self-absorption of the low-energy radiation. A special purpose instrument, AEP-5285, has been designed to simplify the measurement of 125 I activities using a known technique in which the observed counting rate is compensated for self-absorption and any other uncertainties in the counting efficiency by making use of the coicidence properties of the radiation. The instrument contains pulse amplifiers, discriminators to define the energy regions of interest, and operational amplifier circuits to perform the necessary calculations automatically, and it displays an estimate of the source activity in becquerels. (auth)

  16. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  17. Precision Tiltmeter as a Reference for Slope MeasuringInstruments

    Energy Technology Data Exchange (ETDEWEB)

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2007-08-01

    The next generation of synchrotrons and free electron lasers require extremely high-performance x-ray optical systems for proper focusing. The necessary optics cannot be fabricated without the use of precise optical metrology instrumentation. In particular, the Long Trace Profiler (LTP) based on the pencil-beam interferometer is a valuable tool for low-spatial-frequency slope measurement with x-ray optics. The limitations of such a device are set by the amount of systematic errors and noise. A significant improvement of LTP performance was the addition of an optical reference channel, which allowed to partially account for systematic errors associated with wiggling and wobbling of the LTP carriage. However, the optical reference is affected by changing optical path length, non-homogeneous optics, and air turbulence. In the present work, we experimentally investigate the questions related to the use of a precision tiltmeter as a reference channel. Dependence of the tiltmeter performance on horizontal acceleration, temperature drift, motion regime, and kinematical scheme of the translation stage has been investigated. It is shown that at an appropriate experimental arrangement, the tiltmeter provides a slope reference for the LTP system with accuracy on the level of 0.1 {micro}rad (rms).

  18. Precision Tiltmeter as a Reference for Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2007-01-01

    The next generation of synchrotrons and free electron lasers require extremely high-performance x-ray optical systems for proper focusing. The necessary optics cannot be fabricated without the use of precise optical metrology instrumentation. In particular, the Long Trace Profiler (LTP) based on the pencil-beam interferometer is a valuable tool for low-spatial-frequency slope measurement with x-ray optics. The limitations of such a device are set by the amount of systematic errors and noise. A significant improvement of LTP performance was the addition of an optical reference channel, which allowed to partially account for systematic errors associated with wiggling and wobbling of the LTP carriage. However, the optical reference is affected by changing optical path length, non-homogeneous optics, and air turbulence. In the present work, we experimentally investigate the questions related to the use of a precision tiltmeter as a reference channel. Dependence of the tiltmeter performance on horizontal acceleration, temperature drift, motion regime, and kinematical scheme of the translation stage has been investigated. It is shown that at an appropriate experimental arrangement, the tiltmeter provides a slope reference for the LTP system with accuracy on the level of 0.1 (micro)rad (rms)

  19. Cross-cultural adaptation and measurement properties of the Brazilian Version of the Michigan Neuropathy Screening Instrument.

    Science.gov (United States)

    Sartor, Cristina D; Oliveira, Mariana D; Campos, Victoria; Ferreira, Jane S S P; Sacco, Isabel C N

    The Michigan Neuropathy Screening Instrument is an easy-to-use questionnaire aimed at screening and detecting diabetic polyneuropathy. To translate and cross-culturally adapt the MNSI to Brazilian Portuguese and evaluate its measurement properties. Two bilingual translators translated from English into Brazilian Portuguese and made a synthetic version. The synthetic version was back translated into English. A committee of specialists and the translator checked the cultural adaptations and developed a pre-final questionnaire in Brazilian Portuguese (prefinal version). In pretesting, the prefinal version was applied to a sample of 34 subjects in which each subject was interviewed to determine whether they understood each item. For the later assessment of measurement properties, 84 subjects were assessed. A final Brazilian Portuguese version of the instrument was produced after obtaining 80% agreement (SEM0.92), reasonable construct validity for the association between the MNSI and Neuropathy Symptom Score (r=0.46, p<0.05) and excellent association between the MNSI and Neuropathy Disability Score (r=0.79, p<0.05). We did not detect floor and ceiling effects (<9.5% of patients with maximum scores). The Brazilian Portuguese version of the MNSI is suitable for application in the Brazilian diabetic population and is a reliable tool for the screening and detection of DPN. The MNSI can be used both in clinical practice and also for research purposes. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Gene Expression Measurement Module (GEMM) - a fully automated, miniaturized instrument for measuring gene expression in space

    Science.gov (United States)

    Karouia, Fathi; Ricco, Antonio; Pohorille, Andrew; Peyvan, Kianoosh

    2012-07-01

    The capability to measure gene expression on board spacecrafts opens the doors to a large number of experiments on the influence of space environment on biological systems that will profoundly impact our ability to conduct safe and effective space travel, and might also shed light on terrestrial physiology or biological function and human disease and aging processes. Measurements of gene expression will help us to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment on a wide range of organisms from microbes to humans, develop effective countermeasures against these effects, determine metabolic basis of microbial pathogenicity and drug resistance, test our ability to sustain and grow in space organisms that can be used for life support and in situ resource utilization during long-duration space exploration, and monitor both the spacecraft environment and crew health. These and other applications hold significant potential for discoveries in space biology, biotechnology and medicine. Accordingly, supported by funding from the NASA Astrobiology Science and Technology Instrument Development Program, we are developing a fully automated, miniaturized, integrated fluidic system for small spacecraft capable of in-situ measuring microbial expression of thousands of genes from multiple samples. The instrument will be capable of (1) lysing bacterial cell walls, (2) extracting and purifying RNA released from cells, (3) hybridizing it on a microarray and (4) providing electrochemical readout, all in a microfluidics cartridge. The prototype under development is suitable for deployment on nanosatellite platforms developed by the NASA Small Spacecraft Office. The first target application is to cultivate and measure gene expression of the photosynthetic bacterium Synechococcus elongatus, i.e. a cyanobacterium known to exhibit remarkable metabolic diversity and resilience to adverse conditions

  1. Neutron-multiplication measurement instrument

    Energy Technology Data Exchange (ETDEWEB)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1982-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results.

  2. Neutron-multiplication measurement instrument

    International Nuclear Information System (INIS)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1982-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results

  3. [Psychometric properties of Q-DIO, an instrument to measure the quality of documented nursing diagnoses, interventions and outcomes].

    Science.gov (United States)

    Müller-Staub, Maria; Lunney, Margaret; Lavin, Mary Ann; Needham, Ian; Odenbreit, Matthias; van Achterberg, Theo

    2010-04-01

    The instrument Q-DIO was developed in the years 2005 till 2006 to measure the quality of documented nursing diagnoses, interventions, and nursing sensitive patient outcomes. Testing psychometric properties of the Q-DIO (Quality of nursing Diagnoses, Interventions and Outcomes.) was the study aim. Instrument testing included internal consistency, test-retest reliability, interrater reliability, item analyses, and an assessment of the objectivity. To render variation in scores, a random strata sample of 60 nursing documentations was drawn. The strata represented 30 nursing documentations with and 30 without application of theory based, standardised nursing language. Internal consistency of the subscale nursing diagnoses as process showed Cronbach's Alpha 0.83 [0.78, 0.88]; nursing diagnoses as product 0.98 [0.94, 0.99]; nursing interventions 0.90 [0.85, 0.94]; and nursing-sensitive patient outcomes 0.99 [0.95, 0.99]. With Cohen's Kappa of 0.95, the intrarater reliability was good. The interrater reliability showed a Kappa of 0.94 [0.90, 0.96]. Item analyses confirmed the fulfilment of criteria for degree of difficulty and discriminative validity of the items. In this study, Q-DIO has shown to be a reliable instrument. It allows measuring the documented quality of nursing diagnoses, interventions and outcomes with and without implementation of theory based, standardised nursing languages. Studies for further testing of Q-DIO in other settings are recommended. The results implicitly support the use of nursing classifications such as NANDA, NIC and NOC.

  4. Thermodynamic properties and static structure factor for a Yukawa fluid in the mean spherical approximation.

    Science.gov (United States)

    Montes-Perez, J; Cruz-Vera, A; Herrera, J N

    2011-12-01

    This work presents the full analytic expressions for the thermodynamic properties and the static structure factor for a hard sphere plus 1-Yukawa fluid within the mean spherical approximation. To obtain these properties of the fluid type Yukawa analytically it was necessary to solve an equation of fourth order for the scaling parameter on a large scale. The physical root of this equation was determined by imposing physical conditions. The results of this work are obtained from seminal papers of Blum and Høye. We show that is not necessary the use the series expansion to solve the equation for the scaling parameter. We applied our theoretical result to find the thermodynamic and the static structure factor for krypton. Our results are in good agreement with those obtained in an experimental form or by simulation using the Monte Carlo method.

  5. Advanced Instrumentation and Measurement Techniques for Near Surface Flows

    Science.gov (United States)

    Cadel, Daniel R.

    The development of aerodynamic boundary layers on wind turbine blades is an important consideration in their performance. It can be quite challenging to replicate full scale conditions in laboratory experiments, and advanced diagnostics become valuable in providing data not available from traditional means. A new variant of Doppler global velocimetry (DGV) known as cross-correlation DGV is developed to measure boundary layer profiles on a wind turbine blade airfoil in the large scale Virginia Tech Stability Wind Tunnel. The instrument provides mean velocity vectors with reduced sensitivity to external conditions, a velocity measurement range from 0 ms-1 to over 3000 ms-1, and an absolute uncertainty. Monte Carlo simulations with synthetic signals reveal that the processing routine approaches the Cramer-Rao lower bound in optimized conditions. A custom probe-beam technique is implanted to eliminate laser flare for measuring boundary layer profiles on a DU96-W-180 wind turbine airfoil model. Agreement is seen with laser Doppler velocimetry data within the uncertainty estimated for the DGV profile. Lessons learned from the near-wall flow diagnostics development were applied to a novel benchmark model problem incorporating the relevant physical mechanisms of the high amplitude periodic turbulent flow experienced by turbine blades in the field. The model problem is developed for experimentally motivated computational model development. A circular cylinder generates a periodic turbulent wake, in which a NACA 63215b airfoil with a chord Reynolds number Rec = 170,000 is embedded for a reduced frequency k = pi f c/V = 1.53. Measurements are performed with particle image velocimetry on the airfoil suction side and in highly magnified planes within the boundary layer. Outside of the viscous region, the Reynolds stress profile is consistent with the prediction of Rapid Distortion Theory (RDT), confirming that the redistribution of normal stresses is an inviscid effect. The

  6. Mobile Instruments Measure Atmospheric Pollutants

    Science.gov (United States)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  7. A framework and a measurement instrument for sustainability of work practices in long-term care

    Directory of Open Access Journals (Sweden)

    Slaghuis Sarah S

    2011-11-01

    Full Text Available Abstract Background In health care, many organizations are working on quality improvement and/or innovation of their care practices. Although the effectiveness of improvement processes has been studied extensively, little attention has been given to sustainability of the changed work practices after implementation. The objective of this study is to develop a theoretical framework and measurement instrument for sustainability. To this end sustainability is conceptualized with two dimensions: routinization and institutionalization. Methods The exploratory methodological design consisted of three phases: a framework development; b instrument development; and c field testing in former improvement teams in a quality improvement program for health care (N teams = 63, N individual = 112. Data were collected not until at least one year had passed after implementation. Underlying constructs and their interrelations were explored using Structural Equation Modeling and Principal Component Analyses. Internal consistency was computed with Cronbach's alpha coefficient. A long and a short version of the instrument are proposed. Results The χ2- difference test of the -2 Log Likelihood estimates demonstrated that the hierarchical two factor model with routinization and institutionalization as separate constructs showed a better fit than the one factor model (p Conclusions The theoretical framework offers a valuable starting point for the analysis of sustainability on the level of actual changed work practices. Even though the two dimensions routinization and institutionalization are related, they are clearly distinguishable and each has distinct value in the discussion of sustainability. Finally, the subscales conformed to psychometric properties defined in literature. The instrument can be used in the evaluation of improvement projects.

  8. Savannah River Site delayed neutron instruments for safeguards measurements

    International Nuclear Information System (INIS)

    Studley, R.V.

    1992-01-01

    The Savannah River Site (SRS) includes a variety of nuclear production facilities that, since 1953, have processed special nuclear materials (SNM) including highly-enriched uranium (>90% 235 U), recycled enriched uranium (∼50% 235 U + 40% 236 U), low burnup plutonium (> 90% 239 Pu + 240 Pu ) and several other nuclear materials such as heat source plutonium ( 238 Pu). DOE Orders, primarily 5633.3, require all nuclear materials to be safeguarded through accountability and material control. Accountability measurements determine the total amount of material in a facility, balancing inventory changes against receipts and shipments, to provide assurance (delayed) that all material was present. Material control immediately detects or deters theft or diversion by assuring materials remain in assigned locations or by impeding unplanned movement of materials within or from a material access area. Goals for accountability or material control, and, therefore, the design of measurement systems, are distinctly different. Accountability measurements are optimized for maximum precision and accuracy, usually for large amounts of special nuclear material. Material control measurements are oriented more toward security features and often must be optimized for sensitivity, to detect small amounts of materials where none should be

  9. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  10. Physical-Mechanical characterization of cosmetic formulations and correlation between instrumental measurements and sensorial properties.

    Science.gov (United States)

    Calixto, L S; Maia Campos, P M B G

    2017-10-01

    The correct choice of raw materials in the development of cosmetic formulations is essential for obtaining stable and pleasant skin care products. Therefore, rheological, texture and sensory analyses are important to understand the behaviour and stability of the formulations. In this context, the aim of this study was to develop cosmetic formulations containing or not (vehicle) UV filters and chicory root extract, to evaluate their stability as well as to characterize their physical and texture properties and correlate them with the sensory attributes. Four formulations containing organic UV filters and chicory extract, each alone or in combination, were developed and evaluated for 180 days with a cone and plate rheometer, a texture analyzer and consumer's sensorial analysis. Thus, the data obtained were correlated to observe the different influences. The developed formulations remained stable after 180 days regarding macroscopic aspects, organoleptic characteristics and pH values. The addition of the UV filters alone and in combination with the active substance resulted in significant increases in rheology properties, viscosity and consistency. The formulation with the active ingredient showed significant decreases in the texture parameters after 180 days, mainly due to its polysaccharide inulin. All formulations obtained high scores in sensorial parameters. A strong correlation was mainly found between spreadability and work of shear, and between the texture parameters. The raw materials strongly influenced the physical, texture and sensorial parameters. Finally, the UV filters showed a greater influence on the results of the formulations than the chicory root extract. In conclusion, the association of the mentioned methods allows the correct choice of ingredients and their combinations. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  11. 77 FR 2982 - Request for Measures and Domains To Use in Development of a Standardized Instrument for Use in...

    Science.gov (United States)

    2012-01-20

    ... Measures and Domains To Use in Development of a Standardized Instrument for Use in Public Reporting of... Department of Health and Human Services with improving pediatric health care quality measures. The Agency for Healthcare Research and Quality (AHRQ) is soliciting the submission of instruments or domains (for example...

  12. Meteorological Instrumentation and Measurements Open Resource Training Modules for Undergraduate and Graduate Education

    Science.gov (United States)

    Rockwell, A.; Clark, R. D.; Stevermer, A.

    2017-12-01

    The National Center for Atmospheric Research Earth Observing Laboratory, Millersville University and The COMET Program are collaborating to produce a series of nine online modules on the the topic of meteorological instrumentation and measurements. These interactive, multimedia educational modules can be integrated into undergraduate and graduate meteorology courses on instrumentation, measurement science, and observing systems to supplement traditional pedagogies and enhance blended instruction. These freely available and open-source training tools are designed to supplement traditional pedagogies and enhance blended instruction. Three of the modules are now available and address the theory and application of Instrument Performance Characteristics, Meteorological Temperature Instrumentation and Measurements, and Meteorological Pressure Instrumentation and Measurements. The content of these modules is of the highest caliber as it has been developed by scientists and engineers who are at the forefront of the field of observational science. Communicating the availability of these unique and influential educational resources with the community is of high priority. These modules will have a profound effect on the atmospheric observational sciences community by fulfilling a need for contemporary, interactive, multimedia guided education and training modules integrating the latest instructional design and assessment tools in observational science. Thousands of undergraduate and graduate students will benefit, while course instructors will value a set of high quality modules to use as supplements to their courses. The modules can serve as an alternative to observational research training and fill the void between field projects or assist those schools that lack the resources to stage a field- or laboratory-based instrumentation experience.

  13. Pressure/temperature fluid cell apparatus for the neutron powder diffractometer instrument: Probing atomic structure in situ

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hsiu-Wen; Fanelli, Victor R.; Reiche, Helmut M.; Larson, Eric; Taylor, Mark A.; Siewenie, Joan [Lujan Neutron Scattering Center, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Xu, Hongwu [Earth and Environmental Sciences Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Zhu, Jinlong [High Pressure Science and Engineering Center, Department of Physics and Astronomy, The University of Nevada, Las Vegas, Nevada 89154, USA and National Lab for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Page, Katharine, E-mail: pagekl@ornl.gov [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2014-12-15

    This contribution describes a new local structure compatible gas/liquid cell apparatus for probing disordered materials at high pressures and variable temperatures in the Neutron Powder Diffraction instrument at the Lujan Neutron Scattering Center, Los Alamos National Laboratory. The new sample environment offers choices for sample canister thickness and canister material type. Finite element modeling is utilized to establish maximum allowable working pressures of 414 MPa at 15 K and 121 MPa at 600 K. High quality atomic pair distribution function data extraction and modeling have been demonstrated for a calibration standard (Si powder) and for supercritical and subcritical CO{sub 2} measurements. The new sample environment was designed to specifically target experimental studies of the local atomic structures involved in geologic CO{sub 2} sequestration, but will be equally applicable to a wide variety of energy applications, including sorption of fluids on nano/meso-porous solids, clathrate hydrate formation, catalysis, carbon capture, and H{sub 2} and natural gas uptake/storage.

  14. Development of measurement standards for verifying functional performance of surface texture measuring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, A [Life and Industrial Product Development Department Olympus Corporation, 2951 Ishikawa-machi, Hachiouji-shi, Tokyo (Japan); Suzuki, H [Industrial Marketing and Planning Department Olympus Corporation, Shinjyuku Monolith, 3-1 Nishi-Shinjyuku 2-chome, Tokyo (Japan); Yanagi, K, E-mail: a_fujii@ot.olympus.co.jp [Department of Mechanical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka-machi, Nagaoka-shi, Niigata (Japan)

    2011-08-19

    A new measurement standard is proposed for verifying overall functional performance of surface texture measuring instruments. Its surface is composed of sinusoidal surface waveforms of chirp signals along horizontal cross sections of the material measure. One of the notable features is that the amplitude of each cycle in the chirp signal form is geometrically modulated so that the maximum slope is kept constant. The maximum slope of the chirp-like signal is gradually decreased according to movement in the lateral direction. We fabricated the measurement standard by FIB processing, and it was calibrated by AFM. We tried to evaluate the functional performance of Laser Scanning Microscope by this standard in terms of amplitude response with varying slope angles. As a result, it was concluded that the proposed standard can easily evaluate the performance of surface texture measuring instruments.

  15. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yin Peili

    2017-08-01

    Full Text Available Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI. The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  16. Repeatability of oral fluid collection methods for THC measurement.

    NARCIS (Netherlands)

    Houwing, S. Smink, B.E. Legrand, S.-A. Mathijssen, M.P.M. Verstraete, A.G. & Brookhuis, K.A.

    2013-01-01

    The study objective was to determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained by

  17. Repeatability of oral fluid collection methods for THC measurement

    NARCIS (Netherlands)

    Houwing, Sjoerd; Smink, Beitske E.; Legrand, Sara-Ann; Mathijssen, Rene P. M.; Verstraete, Alain G.; Brookhuis, Karel A.

    2012-01-01

    Study objectives: To determine the influence of sample collection for two different collection methods on THC concentrations and to compare THC concentrations collected by both methods. Methods: A total of 136 pairs of oral fluid samples from subjects who had recently smoked Cannabis were obtained

  18. A review of instruments to measure interprofessional collaboration for chronic disease management for community-living older adults.

    Science.gov (United States)

    Bookey-Bassett, Sue; Markle-Reid, Maureen; McKey, Colleen; Akhtar-Danesh, Noori

    2016-01-01

    It is acknowledged internationally that chronic disease management (CDM) for community-living older adults (CLOA) is an increasingly complex process. CDM for older adults, who are often living with multiple chronic conditions, requires coordination of various health and social services. Coordination is enabled through interprofessional collaboration (IPC) among individual providers, community organizations, and health sectors. Measuring IPC is complicated given there are multiple conceptualisations and measures of IPC. A literature review of several healthcare, psychological, and social science electronic databases was conducted to locate instruments that measure IPC at the team level and have published evidence of their reliability and validity. Five instruments met the criteria and were critically reviewed to determine their strengths and limitations as they relate to CDM for CLOA. A comparison of the characteristics, psychometric properties, and overall concordance of each instrument with salient attributes of IPC found the Collaborative Practice Assessment Tool to be the most appropriate instrument for measuring IPC for CDM in CLOA.

  19. Changes in vibrational properties of coated wood through ti me from application of varnish, with recipes used in European or Iranian string instruments making

    OpenAIRE

    Brémaud , Iris; Karami , Elham; Bardet , Sandrine; Gilles , Nicolas; Perego , François; Zare , Samad; Gril , Joseph ,

    2016-01-01

    International audience; The influence of vanishing process on the vibrational properties of the wood+coating systems was studied using different types and recipes of instrument making varnishes, used in traditional Iranian string instruments making, or in European violin-quartet making. The focus is on the time evolution of these properties, that can be involved in the changing behaviour of newly made instruments. The different tested varnishes recipes were applied on wood representative of e...

  20. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service.

    Science.gov (United States)

    Crossno, J E; Berkins, B; Gotcher, N; Hill, J L; McConoughey, M; Walters, M

    2001-04-01

    In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas.

  1. VolcLab: A balloon-borne instrument package to measure ash, gas, electrical, and turbulence properties of volcanic plumes

    Science.gov (United States)

    Airey, Martin; Harrison, Giles; Nicoll, Keri; Williams, Paul; Marlton, Graeme

    2017-04-01

    Release of volcanic ash into the atmosphere poses a significant hazard to air traffic. Exposure to appreciable concentrations (≥4 mg m-3) of ash can result in engine shutdown, air data system loss, and airframe damage, with sustained lower concentrations potentially causing other long-term detrimental effects [1]. Disruption to flights also has a societal impact. For example, the closure of European airspace following the 2010 eruption of Eyjafjallajökull resulted in global airline industry losses of order £1100 million daily and disruption to 10 million passengers. Accurate and effective measurement of the mass of ash in a volcanic plume along with in situ characterisation of other plume properties such as charge, turbulence, and SO2 concentration can be used in combination with plume dispersion modelling, remote sensing, and more sophisticated flight ban thresholds to mitigate the impact of future events. VolcLab is a disposable instrument package that may be attached to a standard commercial radiosonde, for rapid emergency deployment on a weather balloon platform. The payload includes a newly developed gravimetric sensor using the oscillating microbalance principle to measure mass directly without assumptions about particles' optical properties. The package also includes an SO2 gas detector, an optical sensor to detect ash and cloud backscatter from an LED source [2], a charge sensor to characterise electrical properties of the plume [3], and an accelerometer to measure in-plume turbulence [4]. VolcLab uses the established PANDORA interface [5], to provide data exchange and power from the radiosonde. In addition to the VolcLab measurements, the radiosonde provides standard meteorological data of temperature, pressure, and relative humidity, and GPS location. There are several benefits of using this instrument suite in this design and of using this method of deployment. Firstly, this is an all-in-one device requiring minimal expertise on the part of the end

  2. Development of an instrument for direct ozone production rate measurements: measurement reliability and current limitations

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien

    2018-02-01

    Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument

  3. Coexistence properties of the Redlich-Kwong model for a fluid

    International Nuclear Information System (INIS)

    Pina, Eduardo; Selva, Sara MarIa Teresa de la

    2006-01-01

    It is shown in this paper that for pure substances obeying the van der Waals (VdW) equation of state (EOS) or Redlich-Kwong (RK) type equations of state below the critical temperature, it is possible to obtain with the help of the Maxwell equal areas rule the vapour pressure curve, the difference between the molar volume of the vapour and of the liquid, and the difference between the molar entropies of vapour and liquid; each property is obtained in the first step as a dimensionless expression, function of a dimensionless temperature. Any particular property of a particular fluid obeying VdW EOS or one type of RK EOS can be obtained from the corresponding dimensionless expression by multiplying it with a dimension unit which is a function of the particular temperature-dependent parameter a(T) of the EOS considered for the fluid. In the cases of VdW and the original RK (EOS), the dimensionless functions are unique for all the pure fluids that obey the EOS under consideration. A comparison of VdW, RK and RK-Soave (SRK) predictions with experimental vapour pressure data is exemplified for carbon dioxide

  4. Method and apparatus for measuring underground fluid flow characteristics

    International Nuclear Information System (INIS)

    Paap, H.J.; Richter, A.P.; Peelman, H.E.; Arnold, D.M.; Scot, H.D.

    1979-01-01

    This invention relates to the use of neutron activation techniques to measure the azimuth and speed of the horizontal fluid flow in earth formations in the vicinity of a well borehole and the analysis of the resultant gamma radiation based on count rate data obtained as functions of horizontal direction and time. The apparatus consisting of a sonde (a downhole well logging tool) equipped with a neutron source, a gamma detector and a rotatable shield with collimator slot and the data processing equipment located at the surface, are described. (UK)

  5. Standard practice for evaluating performance characteristics of ultrasonic Pulse-Echo testing instruments and systems without the use of electronic measurement instruments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes procedures for evaluating the following performance characteristics of ultrasonic pulse-echo examination instruments and systems: Horizontal Limit and Linearity; Vertical Limit and Linearity; Resolution - Entry Surface and Far Surface; Sensitivity and Noise; Accuracy of Calibrated Gain Controls. Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Instrument characteristics expressed in purely electronic terms may be measured as described in E1324. 1.2 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be ev...

  6. Proposal for a Universal Test Mirror for Characterization of Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Warwick, Tony; Noll, Tino; Siewert, Frank; Zeschke, Thomas; Geckeler, Ralf D.

    2007-01-01

    The development of third generation light sources like the Advanced Light Source (ALS) or BESSY II brought to a focus the need for high performance synchrotron optics with unprecedented tolerances for slope error and micro roughness. Proposed beam lines at Free Electron Lasers (FEL) require optical elements up to a length of one meter, characterized by a residual slope error in the range of 0.1mu rad (rms),and rms values of 0.1 nm for micro roughness. These optical elements must be inspected by highly accurate measuring instruments, providing a measurement uncertainty lower than the specified accuracy of the surface under test. It is essential that metrology devices in use at synchrotron laboratories be precisely characterized and calibrated to achieve this target. In this paper we discuss a proposal for a Universal Test Mirror (UTM) as a realization of a high performance calibration instrument. The instrument would provide an ideal calibration surface to replicate a redundant surface under test of redundant figure. The application of a sophisticated calibration instrument will allow the elimination of the majority of the systematic error from the error budget of an individual measurement of a particular optical element. We present the limitations of existing methods, initial UTM design considerations, possible calibration algorithms, and an estimation of the expected accuracy

  7. Selection and properties of alternative forming fluids for TRISO fuel kernel production

    Energy Technology Data Exchange (ETDEWEB)

    Baker, M.P. [Colorado School of Mines, 1500 Illinois St., Golden, CO 80401 (United States); King, J.C., E-mail: kingjc@mines.edu [Colorado School of Mines, 1500 Illinois St., Golden, CO 80401 (United States); Gorman, B.P. [Colorado School of Mines, 1500 Illinois St., Golden, CO 80401 (United States); Marshall, D.W. [Idaho National Laboratory, 2525 N. Fremont Avenue, P.O. Box 1625, Idaho Falls, ID 83415 (United States)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Forming fluid selection criteria developed for TRISO kernel production. Black-Right-Pointing-Pointer Ten candidates selected for further study. Black-Right-Pointing-Pointer Density, viscosity, and surface tension measured for first time. Black-Right-Pointing-Pointer Settling velocity and heat transfer rates calculated. Black-Right-Pointing-Pointer Three fluids recommended for kernel production testing. - Abstract: Current Very High Temperature Reactor (VHTR) designs incorporate TRi-structural ISOtropic (TRISO) fuel, which consists of a spherical fissile fuel kernel surrounded by layers of pyrolytic carbon and silicon carbide. An internal sol-gel process forms the fuel kernel using wet chemistry to produce uranium oxyhydroxide gel spheres by dropping a cold precursor solution into a hot column of trichloroethylene (TCE). Over time, gelation byproducts inhibit complete gelation, and the TCE must be purified or discarded. The resulting TCE waste stream contains both radioactive and hazardous materials and is thus considered a mixed hazardous waste. Changing the forming fluid to a non-hazardous alternative could greatly improve the economics of TRISO fuel kernel production. Selection criteria for a replacement forming fluid narrowed a list of {approx}10,800 chemicals to yield ten potential replacement forming fluids: 1-bromododecane, 1-bromotetradecane, 1-bromoundecane, 1-chlorooctadecane, 1-chlorotetradecane, 1-iododecane, 1-iodododecane, 1-iodohexadecane, 1-iodooctadecane, and squalane. The density, viscosity, and surface tension for each potential replacement forming fluid were measured as a function of temperature between 25 Degree-Sign C and 80 Degree-Sign C. Calculated settling velocities and heat transfer rates give an overall column height approximation. 1-bromotetradecane, 1-chlorooctadecane, and 1-iodododecane show the greatest promise as replacements, and future tests will verify their ability to form satisfactory

  8. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Science.gov (United States)

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  9. A New Instrument for the Measurement of the Waveform in X-Ray Units

    International Nuclear Information System (INIS)

    Ramirez-Jimenez, Francisco J.; Martinez-Hernandez, Marco A.

    2004-01-01

    The experience gained in the quality control in X-ray units used in Radiology has demonstrated that the measurement of the waveform of the X-ray beam, measured as the response of a radiation detector is very helpful to decide if the unit fulfills the quality control requirements and also has been useful to define some kind of faults in the unit. Several instruments are available on the market to make this measurement but they need in general a storage or digital oscilloscope to see the waveform. In this work a stand alone new instrument is proposed in which the waveform is seen in a Liquid Crystal Display (LCD). The instrument is based in the X-ray response of a photo diode. The analog response depending on time is converted to digital numbers that are stored sequentially in a memory. The stored information is recovered with a microcontroller and reconstructed in the screen of the LCD. The instrument is able to measure in the mammographic range from 22 kV to 35 kV and in the conventional range from 40 kV to 120 kV in the different settings of current encountered on practical applications, the time range for the measurement of the X-ray shot is from 100 ms to 3 s. The instrument can be useful in quality control practices and in the verification and maintenance of X-ray units

  10. On the long-range dependence properties of annual precipitation using a global network of instrumental measurements

    Science.gov (United States)

    Tyralis, Hristos; Dimitriadis, Panayiotis; Koutsoyiannis, Demetris; O'Connell, Patrick Enda; Tzouka, Katerina; Iliopoulou, Theano

    2018-01-01

    The long-range dependence (LRD) is considered an inherent property of geophysical processes, whose presence increases uncertainty. Here we examine the spatial behaviour of LRD in precipitation by regressing the Hurst parameter estimate of mean annual precipitation instrumental data which span from 1916-2015 and cover a big area of the earth's surface on location characteristics of the instrumental data stations. Furthermore, we apply the Mann-Kendall test under the LRD assumption (MKt-LRD) to reassess the significance of observed trends. To summarize the results, the LRD is spatially clustered, it seems to depend mostly on the location of the stations, while the predictive value of the regression model is good. Thus when investigating for LRD properties we recommend that the local characteristics should be considered. The application of the MKt-LRD suggests that no significant monotonic trend appears in global precipitation, excluding the climate type D (snow) regions in which positive significant trends appear.

  11. Thickness measuring instrument for rubber cord calender production

    International Nuclear Information System (INIS)

    Ye Songfeng

    1988-01-01

    The thickness measuring gauge has been used to measure the rubber film thickness on the coating of textile cord at tire four cord calenders. Combined with micro-computer it completes the automatic control system and acheives automatic thickness measurement and adjustment. The fundamentals, construction, specifications, characteristic and application results are described. Prominent economic benefit has been gained for tire production

  12. Psychometric properties of an instrument to measure nursing students' quality of life.

    Science.gov (United States)

    Chu, Yanxiang; Xu, Min; Li, Xiuyun

    2015-07-01

    It is important for clinical nursing teachers and managers to recognize the importance of nursing students' quality of life (QOL) since they are the source of future nurses. As yet, there is no quality of life evaluation scale (QOLES) specific to them. This study designed a quantitative instrument for evaluating QOL of nursing students. The study design was a descriptive survey with mixed methods including literature review, panel discussion, Delphi method, and statistical analysis. The data were collected from 880 nursing students from four teaching hospitals in Wuhan, China. The reliability and validity of the scale were tested through completion of the QOLES in a cluster sampling method. The total scale included 18 items in three domains: physical, psychological, and social functional. The cumulative contributing rate of the three common factors was 65.23%. Cronbach's alpha coefficient of the scale was 0.82. This scale had good reliability and validity to evaluate nursing students' QOL. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Predicting structural properties of fluids by thermodynamic extrapolation

    Science.gov (United States)

    Mahynski, Nathan A.; Jiao, Sally; Hatch, Harold W.; Blanco, Marco A.; Shen, Vincent K.

    2018-05-01

    We describe a methodology for extrapolating the structural properties of multicomponent fluids from one thermodynamic state to another. These properties generally include features of a system that may be computed from an individual configuration such as radial distribution functions, cluster size distributions, or a polymer's radius of gyration. This approach is based on the principle of using fluctuations in a system's extensive thermodynamic variables, such as energy, to construct an appropriate Taylor series expansion for these structural properties in terms of intensive conjugate variables, such as temperature. Thus, one may extrapolate these properties from one state to another when the series is truncated to some finite order. We demonstrate this extrapolation for simple and coarse-grained fluids in both the canonical and grand canonical ensembles, in terms of both temperatures and the chemical potentials of different components. The results show that this method is able to reasonably approximate structural properties of such fluids over a broad range of conditions. Consequently, this methodology may be employed to increase the computational efficiency of molecular simulations used to measure the structural properties of certain fluid systems, especially those used in high-throughput or data-driven investigations.

  14. Radioenzymatic microassay for picogram quantities of serotonin or acetylserotonin in biological fluids and tissues

    International Nuclear Information System (INIS)

    Hussain, M.N.; Benedict, C.R.

    1987-01-01

    This paper describes several modifications of the original radioenzymatic assay for serotonin which increase the sensitivity of the assay 20-fold as well as enhance its reliability. Using this method serotonin concentrations can be directly measured in biological examples without precleaning the sample. When compared to currently available methods this assay is specific and sensitive to approximately 1 pg of serotonin and can be used to measure serotonin levels in individual brain nuclei or microliter quantities of biological fluids. This assay can be easily adapted for the direct measurement of N-acetylserotonin. A large number of samples can be assayed in a single working day

  15. Delayed phenomena analysis from French PWR containment instrumentation system

    International Nuclear Information System (INIS)

    Costaz, J.L.

    1987-01-01

    The analysis of the large amount of measurements which has been now gathered by EDF on its twenty two PWR 900 MW shows that the behaviour of concrete under creep and shrinkage effects is in good agreement with the values given as correct estimates by french regulations and taken into account for the design of nuclear prestressed structures. None of the containment buildings studied here showed significant differences with the regulations theoretical values and consequently all the measurements remain in the field of the allowable strain variations used for design. On the other hand, if the instant loading elastic modulus is clearly determined for each containment, and its effect on theoretical creep taken into account, it was not possible up till now to extract from measurements some particular effects such as type of concrete and agregates or climatic effects. (orig.)

  16. A high sensitivity momentum flux measuring instrument for plasma thruster exhausts and diffusive plasmas.

    Science.gov (United States)

    West, Michael D; Charles, Christine; Boswell, Rod W

    2009-05-01

    A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 microN. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.

  17. Impact of measurable physical phenomena on contact thermal comfort

    Science.gov (United States)

    Fojtlín, Miloš; Pokorný, Jan; Fišer, Jan; Toma, Róbert; Tuhovčák, Ján

    Cabin HVAC (Heating Ventilation and Air-conditioning) systems have become an essential part of personal vehicles as demands for comfortable transport are still rising. In fact, 85 % of the car trips in Europe are shorter than 18 km and last only up to 30 minutes. Under such conditions, the HVAC unit cannot often ensure desired cabin environment and passengers are prone to experience thermal stress. For this reason, additional comfort systems, such as heated or ventilated seats, are available on the market. However, there is no straightforward method to evaluate thermal comfort at the contact surfaces nowadays. The aim of this work is to summarise information about heated and ventilated seats. These technologies use electrical heating and fan driven air to contact area in order to achieve enhanced comfort. It is also expected, that such measures may contribute to lower energy consumption. Yet, in real conditions it is almost impossible to measure the airflow through the ventilated seat directly. Therefore, there is a need for an approach that would correlate measurable physical phenomena with thermal comfort. For this reason, a method that exploits a measurement of temperatures and humidity at the contact area is proposed. Preliminary results that correlate comfort with measurable physical phenomena are demonstrated.

  18. Impact of measurable physical phenomena on contact thermal comfort

    Directory of Open Access Journals (Sweden)

    Fojtlín Miloš

    2017-01-01

    Full Text Available Cabin HVAC (Heating Ventilation and Air-conditioning systems have become an essential part of personal vehicles as demands for comfortable transport are still rising. In fact, 85 % of the car trips in Europe are shorter than 18 km and last only up to 30 minutes. Under such conditions, the HVAC unit cannot often ensure desired cabin environment and passengers are prone to experience thermal stress. For this reason, additional comfort systems, such as heated or ventilated seats, are available on the market. However, there is no straightforward method to evaluate thermal comfort at the contact surfaces nowadays. The aim of this work is to summarise information about heated and ventilated seats. These technologies use electrical heating and fan driven air to contact area in order to achieve enhanced comfort. It is also expected, that such measures may contribute to lower energy consumption. Yet, in real conditions it is almost impossible to measure the airflow through the ventilated seat directly. Therefore, there is a need for an approach that would correlate measurable physical phenomena with thermal comfort. For this reason, a method that exploits a measurement of temperatures and humidity at the contact area is proposed. Preliminary results that correlate comfort with measurable physical phenomena are demonstrated.

  19. Design and construction of an instrument for measuring thermistor electrical characteristic

    International Nuclear Information System (INIS)

    Budiono; Yudi Herdiana

    2007-01-01

    In this work an instrument for measuring the electrical characteristic of thermistor has been designed and constructed. The instrument was constructed from main components i.e. a micro controller AT89C51, 3 ADC-0804, a LM35 temperature sensor and IC MAX 232. The IC MAX 232 component is used to connect the micro controller to the personal computer serially by using RS-232 standard. While ADC-0804 was used to convert the analog data (DC voltage) to the digital one so that the data was readable by the micro controller. Digital data from 3 ADC-0804 circuit which have been read by the micro controller was sent directly to the personal computer. The data from the measurement which have been stored in the personal computer was then processed to know the value of temperature and measured thermistor resistance. The processed data could be either stored in a data base or displayed in a monitor or printed in the form of table data and in the form a graph of thermistor resistance as the function of temperature. The result of measurement from measuring instrument of the characteristic of thermistor electric's had been made, being compared by measuring calibrated instrument, the deviation is about 0.33 %. (author)

  20. Clarification of complex phenomena in nuclear plants present status and future trend of fluid analysis by cellular automaton methods

    International Nuclear Information System (INIS)

    Kato, Yasuyoshi

    1999-01-01

    Since most of complex phenomena comprise of various elementary processes e.g., fluid flow, heat conduction, phase transition, chemical reaction, structural deformation, and these processes interact each other nonlinearly, the complex phenomena cannot be easily clarified by such the conventional topdown approaches as describe phenomena by using differential equations. In contrast to the topdown approaches where the differential equations are located at the top of the analysis procedures, these are bottomup approaches where phenomena are reproduced by local interaction of particles on cells. Cellular automata are one of the typical bottomup approaches. The basic principle, computer simulation results, and massively parallel processors for the cellular automata are reviewed and perspectives of the bottomup approach are discussed on clarification of the complex phenomena in nuclear plants. The computer simulations mainly deal with fluid flows and phase interfacial phenomena. (author)

  1. Measuring and characterizing beat phenomena with a smartphone

    Science.gov (United States)

    Osorio, M.; Pereyra, C. J.; Gau, D. L.; Laguarda, A.

    2018-03-01

    Nowadays, smartphones are in everyone’s life. Apart from being excellent tools for work and communication, they can also be used to perform several measurements of simple physical magnitudes, serving as a mobile and inexpensive laboratory, ideal for use physics lectures in high schools or universities. In this article, we use a smartphone to analyse the acoustic beat phenomena by using a simple experimental setup, which can complement lessons in the classroom. The beats were created by the superposition of the waves generated by two tuning forks, with their natural frequencies previously characterized using different applications. After the characterization, we recorded the beats and analysed the oscillations in time and frequency.

  2. A new approach using artificial neural networks for determination of the thermodynamic properties of fluid couples

    International Nuclear Information System (INIS)

    Sencan, Arzu; Kalogirou, Soteris A.

    2005-01-01

    This paper presents a new approach using artificial neural networks (ANN) to determine the thermodynamic properties of two alternative refrigerant/absorbent couples (LiCl-H 2 O and LiBr + LiNO 3 + LiI + LiCl-H 2 O). These pairs can be used in absorption heat pump systems, and their main advantage is that they do not cause ozone depletion. In order to train the network, limited experimental measurements were used as training and test data. Two feedforward ANNs were trained, one for each pair, using the Levenberg-Marquardt algorithm. The training and validation were performed with good accuracy. The correlation coefficient obtained when unknown data were applied to the networks was 0.9997 and 0.9987 for the two pairs, respectively, which is very satisfactory. The present methodology proved to be much better than linear multiple regression analysis. Using the weights obtained from the trained network, a new formulation is presented for determination of the vapor pressures of the two refrigerant/absorbent couples. The use of this new formulation, which can be employed with any programming language or spreadsheet program for estimation of the vapor pressures of fluid couples, as described in this paper, may make the use of dedicated ANN software unnecessary

  3. FINANCIAL ACCOUNTING MEASUREMENT: INSTRUMENTATION AND CALIBRATION

    OpenAIRE

    stanley c. w. salvary

    2005-01-01

    In its Conceptual Framework (CF), the Financial Accounting Standards Board (FASB) has not identified the observable phenomena and was not able to identify a single measurement property in financial accounting. While identifying aspects of the observable phenomena in financial accounting, the FASB has indicated that there are five measurement attributes which are used in financial accounting and the result is a mixed-attributes model. Lacking a critical underlying theory, the FASB’s Conceptual...

  4. Designing Chemistry Practice Exams for Enhanced Benefits: An Instrument for Comparing Performance and Mental Effort Measures

    Science.gov (United States)

    Knaus, Karen J.; Murphy, Kristen L.; Holme, Thomas A.

    2009-01-01

    The design and use of a chemistry practice exam instrument that includes a measure for student mental effort is described in this paper. Use of such an instrument can beneficial to chemistry students and chemistry educators as well as chemical education researchers from both a content and cognitive science perspective. The method for calculating…

  5. Use of the mathematical modelling method for the investigation of dynamic characteristics of acoustical measuring instruments

    Science.gov (United States)

    Vasilyev, Y. M.; Lagunov, L. F.

    1973-01-01

    The schematic diagram of a noise measuring device is presented that uses pulse expansion modeling according to the peak or any other measured values, to obtain instrument readings at a very low noise error.

  6. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  7. The Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI: design, execution, and early results

    Directory of Open Access Journals (Sweden)

    A. J. M. Piters

    2012-02-01

    Full Text Available From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI. The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR in the Netherlands. Its main objectives were to determine the accuracy of state-of-the-art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing, and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CESAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO2, O4 and HCHO with MAX-DOAS agree within 5 to 15%, vertical profiles of NO2 derived from several independent

  8. Measurement of sound velocity profiles in fluids for process monitoring

    International Nuclear Information System (INIS)

    Wolf, M; Kühnicke, E; Lenz, M; Bock, M

    2012-01-01

    In ultrasonic measurements, the time of flight to the object interface is often the only information that is analysed. Conventionally it is only possible to determine distances or sound velocities if the other value is known. The current paper deals with a novel method to measure the sound propagation path length and the sound velocity in media with moving scattering particles simultaneously. Since the focal position also depends on sound velocity, it can be used as a second parameter. Via calibration curves it is possible to determine the focal position and sound velocity from the measured time of flight to the focus, which is correlated to the maximum of averaged echo signal amplitude. To move focal position along the acoustic axis, an annular array is used. This allows measuring sound velocity locally resolved without any previous knowledge of the acoustic media and without a reference reflector. In previous publications the functional efficiency of this method was shown for media with constant velocities. In this work the accuracy of these measurements is improved. Furthermore first measurements and simulations are introduced for non-homogeneous media. Therefore an experimental set-up was created to generate a linear temperature gradient, which also causes a gradient of sound velocity.

  9. Fluid properties control degassing or storage of abiogenic CH4 during slab exhumation: the fluid inclusion record from the Western Alps.

    Science.gov (United States)

    Ferrando, S.; Castelli, D.; Frezzotti, M. L.

    2017-12-01

    Abiogenic CH4 can be produced by interaction between carbonates and reducing fluids derived from the hydration of ultramafics (e.g., mantle peridotite or HP Ol-serpentinite). This process occurs during slab exhumation because cooling promotes serpentinization of olivine in presence of water (Fo + H2O = Atg + Brc and the linked reactions: Fa + H2O = Fe-Atg + Mag + H2 and Atg + CaCO3 + H2 = Di + Brc + CH4 + H2O) at ca. 500-375°C (P=2.0-0.2 GPa). Experiments in the CH4-H2O-NaCl system indicate that, at these conditions, fluids are immiscible even for very low salinity (ca. 3 wt%) and that the NaCl content in the aqueous part of the fluid increases with temperature whereas the CH4 content in the gaseous part shows an opposite trend (Lamb et al., 2002; Li, 2017).In HP rodingite from the Piemonte ophiolite Zone (W Alps), primary fluid inclusions consisting of a brine (6 wt% CaCl2 + 6 wt% NaCl) with H2 + CH4 ≤ 1 mol % [CH4/(H2+CH4) = 0.37-10] occur in vesuvianite veins that formed at P=0.2 GPa and T=375°C. We interpret them as the aqueous part of an immiscible reducing fluid produced during late Alpine serpentinization of the surrounding ultramafics. Interestingly, CH4-H2 gaseous fluids are never reported in rodingite, whereas early CH4-H2O-H2±graphite and CH4-H2±graphite fluid inclusions, with variable gas-water proportions, trapped in calcite at P≤1.0 GPa and T≤450°C, are recently reported from HP "graphitized" ophicarbonate from the Lanzo peridotite Massif (W Alps; Vitale Brovarone et al., 2017).Both HP ophiolites and partially-serpentinized peridotite massifs are, thus, efficient lithologies to produce CH4 during exhumation. The amount of released CH4 depends on the amount of water available during exhumation. However, when fluids immiscibility occurs, the gaseous-rich part (CH4-H2) of the immiscible fluid produced in ultramafics likely remains confined in the slab because it is less mobile with respect to the aqueous-rich part due to its high dihedral

  10. Investigation of the Acoustic Properties of Chemically Impregnated Kayu Malam Wood Used for Musical Instrument

    Directory of Open Access Journals (Sweden)

    Md. Faruk Hossen

    2018-01-01

    Full Text Available The chemical modification or impregnation through preparing the wood polymer composites (WPCs can effectively reduce the hygroscopicity as well as can improve the acoustic properties of wood. On the other hand, a small amount of nanoclay into the chemical mixture can further improve the different properties of the WPCs through the preparation of wood polymer nanocomposites (WPNCs. Kayu Malam wood species with styrene (St, vinyl acetate (VA, and montmorillonite (MMT nanoclay were used for the preparation of WPNCs. The acoustic properties such as specific dynamic Young’s modulus (Ed/γ, internal friction (Q−1, and acoustic conversion efficiency (ACE of wood were examined using free-free flexural vibration. It was observed that the chemically impregnated wood composite showed a higher value of Ed/γ than raw wood and the nanoclay-loaded wood nanocomposite showed the highest value. The reverse trend was observed in the case of Q−1. On the other hand, chemical impregnation has a minor effect on ACE of wood for musical instruments. The results suggested that the chemically impregnated Kayu Malam wood polymer nanocomposite (WPNC is suitable for making soundboards of violin and guitar instruments to be played longer without losing tone quality.

  11. An instrument for the high-statistics measurement of plastic scintillating fibers

    International Nuclear Information System (INIS)

    Buontempo, S.; Ereditato, A.; Marchetti-Stasi, F.; Riccardi, F.; Strolin, P.

    1994-01-01

    There is today widespread use of plastic scintillating fibers in particle physics, mainly for calorimetric and tracking applications. In the case of calorimeters, we have to cope with very massive detectors and a large quantity of scintillating fibers. The CHORUS Collaboration has built a new detector to search for ν μ -ν τ oscillations in the CERN neutrino beam. A crucial task of the detector is ruled by the high-energy resolution calorimeter. For its construction more than 400 000 scintillating plastic fibers have been used. In this paper we report on the design and performance of a new instrument for the high-statistics measurement of the fiber properties, in terms of light yield and light attenuation length. The instrument has been successfully used to test about 3% of the total number of fibers before the construction of the calorimeter. ((orig.))

  12. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  13. Curvature Dependence of Interfacial Properties for Associating Lennard—Jones Fluids: A Density Functional Study

    International Nuclear Information System (INIS)

    Sun Zong-Li; Kang Yan-Shuang

    2011-01-01

    Classical density functional theory is used to study the associating Lennard—Jones fluids in contact with spherical hard wall of different curvature radii. The interfacial properties including contact density and fluid-solid interfacial tension are investigated. The influences of associating energy, curvature of hard wall and the bulk density of fluids on these properties are analyzed in detail. The results may provide helpful clues to understand the interfacial properties of other complex fluids. (condensed matter: structure, mechanical and thermal properties)

  14. Psychometric Evaluation of an Instrument for Measuring Organizational Climate for Quality: Evidence From a National Sample of Infection Preventionists.

    Science.gov (United States)

    Pogorzelska-Maziarz, Monika; Nembhard, Ingrid M; Schnall, Rebecca; Nelson, Shanelle; Stone, Patricia W

    2016-09-01

    In recent years, there has been increased interest in measuring the climate for infection prevention; however, reliable and valid instruments are lacking. This study tested the psychometric properties of the Leading a Culture of Quality for Infection Prevention (LCQ-IP) instrument measuring the infection prevention climate in a sample of 972 infection preventionists from acute care hospitals. An exploratory principal component analysis showed that the instrument had structural validity and captured 4 factors related to the climate for infection prevention: Psychological Safety, Prioritization of Quality, Supportive Work Environment, and Improvement Orientation. LCQ-IP exhibited excellent internal consistency, with a Cronbach α of .926. Criterion validity was supported with overall LCQ-IP scores, increasing with the number of evidence-based prevention policies in place (P = .047). This psychometrically sound instrument may be helpful to researchers and providers in assessing climate for quality related to infection prevention. © The Author(s) 2015.

  15. Preliminary results of aerosols' optical properties studied with EPF measurements from the SPICAM/UV instrument

    Science.gov (United States)

    Willame, Y.; Vandaele, A.-C.; Depiesse, C.; Gillotay, D.; Kochenova, S.; Montmessin, F.

    2011-10-01

    Aerosols on Mars have an important impact on the radiative transfer properties of its atmosphere. Today their spectral properties and therefore their interaction with UV radiation are only poorly known. Improving the radiative transfer modeling requires a better knowledge of their characteristics, in particular of their phase function, single scattering albedo and opacity. We will show that such information can be accessed by using EPF observations.

  16. Direct measurements of transport properties are essential for site characterization

    International Nuclear Information System (INIS)

    Wright, J.; Conca, J.L.

    1994-08-01

    Direct measurements of transport parameters on subsurface sediments using, the UFA method provided detailed hydrostratigraphic mapping, and subsurface flux distributions at a mixed-waste disposal site at Hanford. Seven hundred unsaturated conductivity measurements on fifty samples were obtained in only six months total of UFA run time. These data are used to provide realistic information to conceptual models, predictive models and restoration strategies. The UFA instrument consists of an ultracentrifuge with a constant, ultralow flow pump that provides fluid to the sample surface through a rotating seal assembly and microdispersal system. Effluent from the sample is collected in a transparent, volumetrically-calibrated chamber at the bottom of the sample assembly. Using a strobe light, an observer can check the chamber while the sample is being centrifuged. Materials can be run in the UFA as recomposited samples or in situ samples can be subcored directly into the sample UFA chamber

  17. Measuring pain phenomena after spinal cord injury: Development and psychometric properties of the SCI-QOL Pain Interference and Pain Behavior assessment tools.

    Science.gov (United States)

    Cohen, Matthew L; Kisala, Pamela A; Dyson-Hudson, Trevor A; Tulsky, David S

    2018-05-01

    To develop modern patient-reported outcome measures that assess pain interference and pain behavior after spinal cord injury (SCI). Grounded-theory based qualitative item development; large-scale item calibration field-testing; confirmatory factor analyses; graded response model item response theory analyses; statistical linking techniques to transform scores to the Patient Reported Outcome Measurement Information System (PROMIS) metric. Five SCI Model Systems centers and one Department of Veterans Affairs medical center in the United States. Adults with traumatic SCI. N/A. Spinal Cord Injury - Quality of Life (SCI-QOL) Pain Interference item bank, SCI-QOL Pain Interference short form, and SCI-QOL Pain Behavior scale. Seven hundred fifty-seven individuals with traumatic SCI completed 58 items addressing various aspects of pain. Items were then separated by whether they assessed pain interference or pain behavior, and poorly functioning items were removed. Confirmatory factor analyses confirmed that each set of items was unidimensional, and item response theory analyses were used to estimate slopes and thresholds for the items. Ultimately, 7 items (4 from PROMIS) comprised the Pain Behavior scale and 25 items (18 from PROMIS) comprised the Pain Interference item bank. Ten of these 25 items were selected to form the Pain Interference short form. The SCI-QOL Pain Interference item bank and the SCI-QOL Pain Behavior scale demonstrated robust psychometric properties. The Pain Interference item bank is available as a computer adaptive test or short form for research and clinical applications, and scores are transformed to the PROMIS metric.

  18. The rhesus measurement system: A new instrument for space research

    Science.gov (United States)

    Schonfeld, Julie E.; Hines, John W.

    1993-01-01

    The Rhesus Research Facility (RRF) is a research environment designed to study the effects of microgravity using rhesus primates as human surrogates. This experimental model allows investigators to study numerous aspects of microgravity exposure without compromising crew member activities. Currently, the RRF is slated for two missions to collect its data, the first mission is SLS-3, due to fly in late 1995. The RRF is a joint effort between the United States and France. The science and hardware portions of the project are being shared between the National Aeronautics and Space Administration (NASA) and France's Centre National D'Etudes Spatiales (CNES). The RRF is composed of many different subsystems in order to acquire data, provide life support, environmental enrichment, computer facilities and measurement capabilities for two rhesus primates aboard a nominal sixteen day mission. One of these subsystems is the Rhesus Measurement System (RMS). The RMS is designed to obtain in-flight physiological measurements from sensors interfaced with the subject. The RMS will acquire, preprocess, and transfer the physiologic data to the Flight Data System (FDS) for relay to the ground during flight. The measurements which will be taken by the RMS during the first flight will be respiration, measured at two different sites; electromyogram (EMG) at three different sites; electroencephalogram (EEG); electrocardiogram (ECG); and body temperature. These measurements taken by the RMS will assist the research team in meeting the science objectives of the RRF project.

  19. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  20. Extension of Generalized Fluid System Simulation Program's Fluid Property Database

    Science.gov (United States)

    Patel, Kishan

    2011-01-01

    This internship focused on the development of additional capabilities for the General Fluid Systems Simulation Program (GFSSP). GFSSP is a thermo-fluid code used to evaluate system performance by a finite volume-based network analysis method. The program was developed primarily to analyze the complex internal flow of propulsion systems and is capable of solving many problems related to thermodynamics and fluid mechanics. GFSSP is integrated with thermodynamic programs that provide fluid properties for sub-cooled, superheated, and saturation states. For fluids that are not included in the thermodynamic property program, look-up property tables can be provided. The look-up property tables of the current release version can only handle sub-cooled and superheated states. The primary purpose of the internship was to extend the look-up tables to handle saturated states. This involves a) generation of a property table using REFPROP, a thermodynamic property program that is widely used, and b) modifications of the Fortran source code to read in an additional property table containing saturation data for both saturated liquid and saturated vapor states. Also, a method was implemented to calculate the thermodynamic properties of user-fluids within the saturation region, given values of pressure and enthalpy. These additions required new code to be written, and older code had to be adjusted to accommodate the new capabilities. Ultimately, the changes will lead to the incorporation of this new capability in future versions of GFSSP. This paper describes the development and validation of the new capability.

  1. Search for New Phenomena Using W/Z + (b)-Jets Measurements Performed with the ATLAS Detector

    International Nuclear Information System (INIS)

    Beauchemin, Pierre-Hugues

    2015-01-01

    The Project proposed to use data of the ATLAS experiment, obtained during the 2011 and 2012 data-taking campaigns, to pursue studies of the strong interaction (QCD) and to examine promising signatures for new physics. The Project also contains a service component dedicated to a detector development initiative. The objective of the strong interaction studies is to determine how various predictions from the main theory (QCD) compare to the data. Results of a set of measurements developed by the Tufts team indicate that the dominant factor of discrepancy between data and QCD predictions come from the mis-modeling of the low energy gluon radiation as described by algorithms called parton showers. The discrepancies introduced by parton showers on LHC predictions could even be larger than the effect due to completely new phenomena (dark matter, supersymmetry, etc.) and could thus block further discoveries at the LHC. Some of the results obtained in the course of this Project also specify how QCD predictions must be improved in order to open the possibility for the discovery of something completely new at the LHC during Run-II. This has been integrated in the Run-II ATLAS physics program. Another objective of Tufts studies of the strong interaction was to determine how the hypothesis about an intrinsic heavy-quark component of the proton (strange, charm or bottom quarks) could be tested at the LHC. This hypothesis has been proposed by theorists 30 years ago and is still controversial. The Tufts team demonstrated that intrinsic charms can be observed, or severely constrained, at the LHC, and determine how the measurement should be performed in order to maximize its sensitivity to such an intrinsic heavy-quark component of the proton. Tufts also embarked on performing the measurement that is in progress, but final results are not yet available. They should shade a light of understanding on the fundamental structure of the proton. Determining the nature of dark matter

  2. Measurement of the Thermal Conductivity of Nano-fluid for the advanced heat exchanger

    International Nuclear Information System (INIS)

    Yoo, Shin; Lee, Jae Young

    2006-01-01

    The enhancement of heat transfer has been widely investigated to provide an effective way to cool down the modern electronic devices. Among the methods, Choi discovered a large amount of increase of thermal conductivity when nano sized particles were suspended in the fluid. It was first introduced by Masuda as a potential heat transfer enhancement media and since then, many researchers have investigated the nanofluids phenomena. Many researchers reported in substantially increasing the thermal conductivity of fluids by adding small amounts of suspended metallic oxide nanoparticles of Cu, CuO, Al 2 O 3 and carbon nano-tube. Masuda reported that the use Al 2 O 3 particles of 13 nm at 4.3% volume fraction increased the thermal conductivity of water by 30%. For carbon nano-tube nanofluids shows even greater enhancement. Xie et al. measured the thermal conductivity of carbon nanotube suspended in organic liquid and water with the enhancement of 10-20%. Recent studies have shown that inserting just 1% concentration of nano-particles sometimes increases about maximum 40% of thermal conductivity. However, there is still few experiments done for TiO 2 nanoparticles. Murshed found that the enhancement of thermal conductivity shows about 30% with 15nm in diameter with maximum 5% volume fraction and about 40% enhancement is observed using 15nmD x 40nm rod-shape nanoparticles of TiO 2 . The present experimental shows that a 20% maximum of enhancement in thermal conductivity using TiO 2 of 10nm for 3% volume fraction. Theses results are compared with previous research with theoretical models. As the first step of the heat transfer of nano fluid, the theories related to the nanofluids investigations have been discussed to understand not only the mechanism of thermal conductivity measurement, but also to understand the nanofluid behavior. Colloidal stability is the key to the nanofluid considered to prevent the agglomeration. Through the results, we will discuss the importance of

  3. Heights integrated model as instrument for simulation of hydrodynamic, radiation transport, and heat conduction phenomena of laser-produced plasma in EUV applications.

    Energy Technology Data Exchange (ETDEWEB)

    Sizyuk, V.; Hassanein, A.; Morozov, V.; Sizyuk, T.; Mathematics and Computer Science

    2007-01-16

    The HEIGHTS integrated model has been developed as an instrument for simulation and optimization of laser-produced plasma (LPP) sources relevant to extreme ultraviolet (EUV) lithography. The model combines three general parts: hydrodynamics, radiation transport, and heat conduction. The first part employs a total variation diminishing scheme in the Lax-Friedrich formulation (TVD-LF); the second part, a Monte Carlo model; and the third part, implicit schemes with sparse matrix technology. All model parts consider physical processes in three-dimensional geometry. The influence of a generated magnetic field on laser plasma behavior was estimated, and it was found that this effect could be neglected for laser intensities relevant to EUV (up to {approx}10{sup 12} W/cm{sup 2}). All applied schemes were tested on analytical problems separately. Benchmark modeling of the full EUV source problem with a planar tin target showed good correspondence with experimental and theoretical data. Preliminary results are presented for tin droplet- and planar-target LPP devices. The influence of three-dimensional effects on EUV properties of source is discussed.

  4. Measuring Instruments Control Methodology Performance for Analog Electronics Remote Labs

    Directory of Open Access Journals (Sweden)

    Unai Hernandez-Jayo

    2012-12-01

    Full Text Available This paper presents the work that has been developed in parallel to the VISIR project. The objective of this paper is to present the results of the validations processes that have been carried out to check the control methodology. This method has been developed with the aim of being independent of the instruments of the labs.

  5. Smartphone measurement engineering - Innovative challenges for science and education, instrumentation and training

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, D; Dittrich, P-G; Duentsch, E [Senior Network Manager NEMO SpectroNet, Technologie- und Innovationspark Jena GmbH, Wildenbruchstrasse 15, D-07745 Jena (Germany)

    2010-07-01

    Smartphones have an enormous conceptual and structural influence on measurement science and education, instrumentation and training. Smartphones are matured. They became convenient, reliable and affordable. In 2009 worldwide 174 million Smartphones has been delivered. Measurement with Smartphones is ready for the future. In only 10 years the German vision industry tripled its global sales volume to one Billion Euro/Year. Machine vision is used for mobile object identification, contactless industrial quality control, personalized health care, remote facility and transport management, safety critical surveillance and all tasks which are too complex for the human eye or too monotonous for the human brain. Aim of the paper is to describe selected success stories for the application of Smartphones for measurement engineering in science and education, instrumentation and training.

  6. Smartphone measurement engineering - Innovative challenges for science and education, instrumentation and training

    International Nuclear Information System (INIS)

    Hofmann, D; Dittrich, P-G; Duentsch, E

    2010-01-01

    Smartphones have an enormous conceptual and structural influence on measurement science and education, instrumentation and training. Smartphones are matured. They became convenient, reliable and affordable. In 2009 worldwide 174 million Smartphones has been delivered. Measurement with Smartphones is ready for the future. In only 10 years the German vision industry tripled its global sales volume to one Billion Euro/Year. Machine vision is used for mobile object identification, contactless industrial quality control, personalized health care, remote facility and transport management, safety critical surveillance and all tasks which are too complex for the human eye or too monotonous for the human brain. Aim of the paper is to describe selected success stories for the application of Smartphones for measurement engineering in science and education, instrumentation and training.

  7. Non-linear hydrotectonic phenomena: Part I - fluid flow in open fractures under dynamical stress loading

    International Nuclear Information System (INIS)

    Archambeau, C.B.

    1994-01-01

    A fractured solid under stress loading (or unloading) can be viewed as behaving macroscopically as a medium with internal, hidden, degrees of freedom, wherein changes in fracture geometry (i.e. opening, closing and extension) and flow of fluid and gas within fractures will produce major changes in stresses and strains within the solid. Likewise, the flow process within fractures will be strongly coupled to deformation within the solid through boundary conditions on the fracture surfaces. The effects in the solid can, in part, be phenomenologically represented as inelastic or plastic processes in the macroscopic view. However, there are clearly phenomena associated with fracture growth and open fracture fluid flows that produce effects that can not be described using ordinary inelastic phenomenology. This is evident from the fact that a variety of energy release phenomena can occur, including seismic emissions of previously stored strain energy due to fracture growth, release of disolved gas from fluids in the fractures resulting in enhanced buoyancy and subsequent energetic flows of gas and fluids through the fracture system which can produce raid extension of old fractures and the creation of new ones. Additionally, the flows will be modulated by the opening and closing of fractures due to deformation in the solid, so that the flow process is strongly coupled to dynamical processes in the surrounding solid matrix, some of which are induced by the flow itself

  8. The Second Cabauw Intercomparison Campaign for Nitrogen Dioxide Measuring Instruments — CINDI-2 — Overview

    Science.gov (United States)

    Apituley, Arnoud; van Roozendael, Michel; Hendrick, Francois; Kreher, Karin; Richter, Andreas; Wagner, Thomas; Friess, Udo; Participants, Cindi-2

    2017-04-01

    For the validation of space borne observations of NO2 and other trace gases from hyperspectral imagers, ground based instruments based on the MAXDOAS technique are an excellent choice, since they rely on similar retrieval techniques as the observations from orbit. In both cases, retrievals take into account the light path of scattered sunlight though the entire atmosphere. Since MAXDOAS instruments are relatively low cost and can be operated autonomously almost anywhere, they are credible candidates to form a world-wide ground based reference network for satellite observations. To ensure proper traceability of the MAXDOAS observations, a thorough intercomparison is mandatory. The Cabauw Experimental Site for Atmospheric Research (CESAR) site in centre of The Netherlands was the stage of the Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments (CINDI) in June-July 2009 and again for the second campaign, CINDI-2, in 2016. Cabauw was chosen because the flat terrain offered a free view of large parts of the horizon, needed to accommodate the viewing geometry of the MAXDOAS observations. The location is under influence of both clean as well as polluted airmasses. This gives a wide range of possible trace gas concentrations and mixtures. Furthermore, at CESAR a wide range of observations are routinely carried out that fulfil the requirement to provide the background necessary for unraveling the differences between the observations from different MAXDOAS instruments that can be quite diverse in design and data treatment. These observations include parameters needed to understand the light paths, i.e. in-situ aerosol observations of optical and microphysical properties, as well as vertical profiles of aerosol optical properties by (Raman) lidar. In addition, vertical profiles of NO2 could be measured during CINDI-2 using the unique NO2 sonde, and a NO2 lidar system. With the imminent launch of Sentinel-5 Precursor/TROPOMI, with a nadir pixelsize of 3.5 × 3

  9. Measurement system for ultrahigh temperature thermophysical properties

    International Nuclear Information System (INIS)

    Fukuyama, Hiroyuki

    2015-01-01

    Properties and Simulations Probed with Electromagnetic Containerless Technique (PROSPECT) is a measurement system for ultrahigh temperature thermophysical properties to be able to measure thermophysical properties with high precision by combining AC magnetic field (electromagnetic levitation device) and DC magnetic field (superconducting magnet) to realize the static floating state of metallic melt, in other words, the state of suppressing the surface vibration of droplets, translational motion, and internal convection. The electromagnetic levitation method is a method to obtain a floating force due to the Lorentz force generated by the interaction between high-frequency current flowing in the coil and the induced current generated in a sample, and to heat/melt the sample with the Joule heat generated by its induced current. This paper roughly explains the element technologies of PROSPECT with a focus on the laser modulation calorimetry (laser periodic heating method), normal spectral emissivity measurement method, density measurement, and surface tension measurement method. Furthermore, as the application of PROSPECT to new research deployment, it introduces the observation of phase separation structure in the supercooled solidification structure of Cu-Co alloy. (A.O.)

  10. In-Situ Measurements of Aerosol Optical Properties using New Cavity Ring-Down and Photoacoustics Instruments and Comparison with more Traditional Techniques

    Science.gov (United States)

    Strawa, A. W.; Arnott, P.; Covert, D.; Elleman, R.; Ferrare, R.; Hallar, A. G.; Jonsson, H.; Kirchstetter, T. W.; Luu, A. P.; Ogren, J.

    2004-01-01

    Carbonaceous species (BC and OC) are responsible for most of the absorption associated with aerosol particles. The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult aerosol properties to measure. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-ARC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Aerosol absorption coefficient is also measured by a photoacoustic (PA) instrument (DRI) that was operated on an aircraft for the first time during the DOE Aerosol Intensive Operating Period (IOP). This paper will report on measurements made with this new instrument and other in-situ instruments during two field recent field studies. The first field study was an airborne cam;oaign, the DOE Aerosol Intensive Operating Period flown in May, 2003 over northern Oklahoma. One of the main purposes of the IOP was to assess our ability to measure extinction and absorption coefficient in situ. This paper compares measurements of these aerosol optical properties made by the CRD, PA, nephelometer, and Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model. The second study was conducted in the Caldecott Tunnel, a heavily-used tunnel located north of San Francisco, Ca. The aerosol sampled in this study was

  11. MITIGATING INNOVATION RISKS CONCERNING INTELLECTUAL PROPERTY INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    Andreea DUMITRESCU

    2014-11-01

    Full Text Available As protection of innovation is possible using a variety of intellectual property instruments, the current paper aims at emphasizing the vulnerabilities of these instruments in order to facilitate the right choice in terms of protection, exploitation and dissemination of innovation. Based on a review of the intellectual property instruments and their related risk factors, the study identifies and formulates specific proactive strategies which arise from the fact that an instrument alone does not allow for effective protection, exploitation and dissemination and oftentimes the owners of innovation should combine traditional and alternative instruments. Therefore, the results of this analysis represent a helpful tool for managers in the decisional process.

  12. Plan for the testing of radiation measurement instrumentation intended for use at an excavation site

    International Nuclear Information System (INIS)

    Gehrke, R.J.

    1994-11-01

    This plan describes performance tests to be made with ionizing radiation measurement instrumentation designed and built for in-field assay at an excavation site. One instrument measures gross gamma-ray and neutron fields and the other identifies gamma-ray emitting radionuclides and also is capable of assaying for selected hazardous materials. These instruments will be operationally tested to verify that original specifications have been met and performance tested to establish and verify that they have the potential to function as intended at an excavation site

  13. New instrument for tribocharge measurement due to single particle impacts

    International Nuclear Information System (INIS)

    Watanabe, Hideo; Ghadiri, Mojtaba; Matsuyama, Tatsushi; Ding Yulong; Pitt, Kendal G.

    2007-01-01

    During particulate solid processing, particle-particle and particle-wall collisions can generate electrostatic charges. This may lead to a variety of problems ranging from fire and explosion hazards to segregation, caking, and blocking. A fundamental understanding of the particle charging in such situations is therefore essential. For this purpose we have developed a new device that can measure charge transfer due to impact between a single particle and a metal plate. The device consists of an impact test system and two sets of Faraday cage and preamplifier for charge measurement. With current amplifiers, high-resolution measurements of particle charges of approximately 1 and 10 fC have been achieved before and after the impact, respectively. The device allows charge measurements of single particles with a size as small as ∼100 μm impacting on the target at different incident angles with a velocity up to about 80 m/s. Further analyses of the charge transfer as a function of particle initial charge define an equilibrium charge, i.e., an initial charge level prior to impact for which no net charge transfer would occur as a result of impact

  14. Gene Expression Measurement Module (GEMM) - A Fully Automated, Miniaturized Instrument for Measuring Gene Expression in Space

    Science.gov (United States)

    Pohorille, Andrew; Peyvan, Kia; Karouia, Fathi; Ricco, Antonio

    2012-01-01

    The capability to measure gene expression on board spacecraft opens the door to a large number of high-value experiments on the influence of the space environment on biological systems. For example, measurements of gene expression will help us to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment on a wide range of organisms from microbes to humans, develop effective countermeasures against these effects, and determine the metabolic bases of microbial pathogenicity and drug resistance. These and other applications hold significant potential for discoveries in space biology, biotechnology, and medicine. Supported by funding from the NASA Astrobiology Science and Technology Instrument Development Program, we are developing a fully automated, miniaturized, integrated fluidic system for small spacecraft capable of in-situ measurement of expression of several hundreds of microbial genes from multiple samples. The instrument will be capable of (1) lysing cell walls of bacteria sampled from cultures grown in space, (2) extracting and purifying RNA released from cells, (3) hybridizing the RNA on a microarray and (4) providing readout of the microarray signal, all in a single microfluidics cartridge. The device is suitable for deployment on nanosatellite platforms developed by NASA Ames' Small Spacecraft Division. To meet space and other technical constraints imposed by these platforms, a number of technical innovations are being implemented. The integration and end-to-end technological and biological validation of the instrument are carried out using as a model the photosynthetic bacterium Synechococcus elongatus, known for its remarkable metabolic diversity and resilience to adverse conditions. Each step in the measurement process-lysis, nucleic acid extraction, purification, and hybridization to an array-is assessed through comparison of the results obtained using the instrument with

  15. Synthesis of FeCo magnetic nanoalloys and investigation of heating properties for magnetic fluid hyperthermia

    Science.gov (United States)

    Çelik, Özer; Fırat, Tezer

    2018-06-01

    In this study, size controlled FeCo colloidal magnetic nanoalloys in the range of 11.5-37.2 nm were synthesized by surfactant assistant ball milling method. Magnetic separation technique was performed subsequent to synthesis process so as to obtain magnetic nanoalloy fluid with narrow size distribution. Particle distribution was determined by transmission electron microscope (TEM) while X-ray diffraction (XRD) measurements verified FeCo alloy formation as BCC structure. Vibrating sample magnetometer (VSM) method was used to investigate magnetic properties of nanoalloys. Maximum saturation magnetization and maximum coercivity were obtained as 172 Am2/kg for nanoparticles with the mean size of 37.2 nm and 19.4 mT for nanoparticles with the mean size of 13.3 nm, respectively. The heating ability of FeCo magnetic nanoalloys was determined through calorimetrical measurements for magnetic fluid hyperthermia (MFH) applications. Heat generation mechanisms were investigated by using linear response theory and Stoner-Wohlfarth (S-W) model. Specific absorption rate (SAR) values were obtained in the range of 2-15 W/g for magnetic field frequency of 171 kHz and magnetic field strength in between 6 and 14 mT.

  16. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  17. An exploratory study of using external fluid loading on a vibrating tube for measuring suspended sediment concentration in water

    International Nuclear Information System (INIS)

    Hsu, Y-S; Hwang, Y-F; Huang, J H

    2008-01-01

    This paper presents an exploratory study of using external fluid loading on a vibrating tube for measuring the suspended sediment concentration (SSC) in bodies of water such as rivers and reservoirs. This new measuring concept provides an opportunity for an automated on-site monitoring of the conditions in a body of water by taking the fluid sample instantaneously in the area surrounding the vibrating tube. The physical properties of the fluid sample are those of the fluid that naturally flows around the tube, and are more representative of those of the water with SSC to be measured. The theoretical analysis presented in this paper shows that the resonance frequencies of an immersed vibrating tube change significantly with mass density variations that normally occur in bodies of water with suspended sediment. These changes are sensitive enough to have a possible 1% resolution of the measured fluid density. The signal processing issues are discussed, and a schematic of a conceptual measuring setup is proposed. Based on the theoretical analyses and other measurement issues presented in the paper, using the loading by external fluid on a vibrating tube is feasible for measuring the SSC in water bodies

  18. A wireless pH sensor using magnetoelasticity for measurement of body fluid acidity.

    Science.gov (United States)

    Pang, Pengfei; Gao, Xianjuan; Xiao, Xilin; Yang, Wenyue; Cai, Qingyun; Yao, Shouzhuo

    2007-04-01

    The determination of body fluid acidity using a wireless magnetoelastic pH-sensitive sensor is described. The sensor was fabricated by casting a layer of pH-sensitive polymer on a magnetoelastic ribbon. In response to an externally applied time-varying magnetic field, the magnetoelastic sensor mechanically vibrates at a characteristic frequency that is inversely dependent upon the mass of the pH polymer film, which varies as the film swells and shrinks in response to pH. As the magnetoelastic sensor is magnetostrictive, the mechanical vibrations of the sensor launch magnetic flux that can be detected remotely using a pickup coil. The sensor can be used for direct measurements of body fluid acidity without a pretreatment of the sample by using a filtration membrane. A reversible and linear response was obtained between pH 5.0 and 8.0 with a measurement resolution of pH 0.1 and a slope of 0.2 kHz pH(-1). Since there are no physical connections between the sensor and the instrument, the sensor can be applied to in vivo and in situ monitoring of the physiological pH and its fluctuations.

  19. Three-dimensional multi-phase flow computational fluid dynamics model for analysis of transport phenomena and thermal stresses in PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Maher, A.R.; Al-Baghdadi, S. [International Technological Univ., London (United Kingdom). Dept. of Mechanical Engineering; Haroun, A.K.; Al-Janabi, S. [Babylon Univ., Babylon (Iraq). Dept. of Mechanical Engineering

    2007-07-01

    Fuel cell technology is expected to play an important role in meeting the growing demand for distributed generation because it can convert the chemical energy of a clean fuel directly into electrical energy. An operating fuel cell has varying local conditions of temperature, humidity, and power generation across the active area of the fuel cell in 3D. This paper presented a model that was developed to improve the basic understanding of the transport phenomena and thermal stresses in PEM fuel cells, and to investigate the behaviour of polymer membrane under hygro and thermal stresses during the cell operation. This comprehensive 3D, multiphase, non-isothermal model accounts for the major transport phenomena in a PEM fuel cell, notably convective and diffusive heat and mass transfer; electrode kinetics; transport and phase change mechanism of water; and potential fields. The model accounts for the liquid water flux inside the gas diffusion layers by viscous and capillary forces and can therefore predict the amount of liquid water inside the gas diffusion layers. This study also investigated the key parameters affecting fuel cell performance including geometry, materials and operating conditions. The model considers the many interacting, complex electrochemical, transport phenomena, thermal stresses and deformation that cannot be studied experimentally. It was concluded that the model can provide a computer-aided tool for the design and optimization of future fuel cells with much higher power density and lower cost. 21 refs., 2 tabs., 14 figs.

  20. 40 CFR 86.1320-90 - Gas meter or flow instrumentation calibration; particulate, methanol, and formaldehyde measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures § 86.1320-90 Gas meter or flow..., methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...

  1. Mercury-free PVT apparatus for thermophysical property analyses of hydrocarbon reservoir fluids. Final report, August 16, 1990--July 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Lansangan, R.M.; Lievois, J.S.

    1992-08-31

    Typical reservoir fluid analyses of complex, multicomponent hydrocarbon mixtures include the volumetric properties, isothermal compressibility, thermal expansivity, equilibrium ratios, saturation pressure, viscosities, etc. These parameters are collectively referred to as PVT properties, an acronym for the primary state variables; pressure, volume, and temperature. The reservoir engineer incorporates this information together with the porous media description in performing material balance calculations. These calculations lead to the determination (estimation) of the initial hydrocarbon in-place, the future reservoir performance, the optimal production scheme, and the ultimate hydrocarbon recovery. About four years ago, Ruska Instrument Corporation embarked on a project to develop an apparatus designed to measure PVT properties that operates free of mercury. The result of this endeavor is the 2370 Hg-Free PVT system which has been in the market for the last three years. The 2370 has evolved from the prototype unit to its present configuration which is described briefly in this report. The 2370 system, although developed as a system-engineered apparatus based on existing technology, has not been exempt from this burden-of-proof Namely, the performance of the apparatus under routine test conditions with real reservoir fluids. This report summarizes the results of the performance and applications testing of the 2370 Hg-Free PVT system. Density measurements were conducted on a pure fluid. The results were compared against literature values and the prediction of an equation of state. Routine reservoir fluid analyses were conducted with a black oil and a retrograde condensate gas mixtures. Limited comparison of the results were performed based on the same tests performed on a conventional mercury-based PVT apparatus. The results of these tests are included in this report.

  2. Psychometric properties of the Specific Thalassemia Quality of Life Instrument for adults

    Directory of Open Access Journals (Sweden)

    Lyrakos GN

    2012-07-01

    Full Text Available Georgios N Lyrakos,1,2 Demetra Vini,2 Helen Aslani,2 Marouso Drosou-Servou212nd Department of Anesthesiology, School of Medicine, University of Athens, Pain Clinic, Attikon University Hospital, 2Thalassemia Unit, General Hospital of Nikaia Ag. Panteleimon, Athens, GreeceBackground: No specific questionnaire has been developed to assess the health-related quality of life of thalassemia patients. Thus, the main objective of this study was to develop, according to psychometric standards, a self-administered Specific Thalassemia Quality of Life Instrument (STQOLI for adult patients.Methods: First, a qualitative phase was conducted to generate items and identify domains using the critical analysis incident technique and a literature review. A list of easily comprehensible, non-redundant items was defined using the Delphi technique and a pilot study on ten thalassemia patients. This phase involved both patients and experts. The second step was a quantitative validation phase comprising a study of 128 thalassemia patients in a single hospital. It was designed to select items, identify dimensions, and measure reliability and internal and concurrent validity. The psychometric and scaling properties of the proposed 41-item Specific Thalassemia Quality of Life Instrument were then assessed among patients recruited from the Thalassemia Unit at the General Hospital of Nikaia, Greece.Results: The final questionnaire had 41 items comprising four main domains and one global item about general health. The factorial structure was satisfactory (loading > 0.40 on each factor of the four domains for all items. Interscale correlations ranged from 0.06 to 0.78, Cronbach's α-coefficients were 0.78 for the psychosocial domain, 0.77 for the chelation domain, 0.72 for the transfusion domain, 0.81 for the disease and symptoms domain, and 0.840 for the total score of the questionnaire.Conclusion: The 41-item Specific Thalassemia Quality of Life Instrument seems to be a

  3. Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device.

    Science.gov (United States)

    Throckmorton, Amy L; Untaroiu, Alexandrina; Lim, D Scott; Wood, Houston G; Allaire, Paul E

    2007-05-01

    The latest generation of artificial blood pumps incorporates the use of magnetic bearings to levitate the rotating component of the pump, the impeller. A magnetic suspension prevents the rotating impeller from contacting the internal surfaces of the pump and reduces regions of stagnant and high shear flow that surround fluid or mechanical bearings. Applying this third-generation technology, the Virginia Artificial Heart Institute has developed a ventricular assist device (VAD) to support infants and children. In consideration of the suspension design, the axial and radial fluid forces exerted on the rotor of the pediatric VAD were estimated using computational fluid dynamics (CFD) such that fluid perturbations would be counterbalanced. In addition, a prototype was built for experimental measurements of the axial fluid forces and estimations of the radial fluid forces during operation using a blood analog mixture. The axial fluid forces for a centered impeller position were found to range from 0.5 +/- 0.01 to 1 +/- 0.02 N in magnitude for 0.5 +/- 0.095 to 3.5 +/- 0.164 Lpm over rotational speeds of 6110 +/- 0.39 to 8030 +/- 0.57% rpm. The CFD predictions for the axial forces deviated from the experimental data by approximately 8.5% with a maximum difference of 18% at higher flow rates. Similarly for the off-centered impeller conditions, the maximum radial fluid force along the y-axis was found to be -0.57 +/- 0.17 N. The maximum cross-coupling force in the x direction was found to be larger with a maximum value of 0.74 +/- 0.22 N. This resulted in a 25-35% overestimate of the radial fluid force as compared to the CFD predictions; this overestimation will lead to a far more robust magnetic suspension design. The axial and radial forces estimated from the computational results are well within a range over which a compact magnetic suspension can compensate for flow perturbations. This study also serves as an effective and novel design methodology for blood pump

  4. Spinning phenomena and energetics of spherically pulsating patterns in stratified fluids

    International Nuclear Information System (INIS)

    Ibragimov, Ranis N; Dameron, Michael

    2011-01-01

    The nonlinear solutions of the two-dimensional Boussinesq equations describing internal waves in rotating stratified fluids were obtained as group invariant solutions. The latter nonlinear solutions correspond to the rotation transformation preserving the form of the original nonlinear equations of motion. It is shown that the obtained class of exact solutions can be associated with the spherically pulsating patterns observed in uniformly stratified fluids. It is also shown that the obtained rotationally symmetric solutions are bounded functions that can be visualized as spinning patterns in stratified fluids. It is also shown that the rotational transformation provides the energy conservation law together with other conservation laws for which the spinning phenomena is observed. The effects of nonlinearity and the Earth's rotation on such a phenomenon are also discussed.

  5. The "Intentionality Measurement Instrument" [or "IMI"]: A Comprehensive Psychometric Instrument Based upon the Dual Quadrant Scalar Model of Intentionality That Is Designed to Measure Intent, Motive Type, and Disposition

    Science.gov (United States)

    Osler, James Edward, II

    2016-01-01

    The overall aim of this paper is to provide an epistemological rational for the measurement of intentionality. The purpose of this narrative is to identify "Intentionality" as an arena of action in the dispositional learning domain can be measured using an "Intentionality Measurement Instrument" [also referred by the acronym…

  6. Measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1976-08-01

    The purpose of this work has been an analysis and evaluation of the state-of-the-art of measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities. The occurrence of plutonium and uranium in the nuclear fuel cycle, the corresponding potential for releases, associated radiological protection standards and monitoring objectives are discussed. Techniques for monitoring via decay radiation from plutonium and uranium isotopes are presented in detail, emphasizing air monitoring, but also including soil sampling and survey methods. Additionally, activation and mass measurement techniques are discussed. The availability and prevalence of these various techniques are summarized. Finally, possible improvements in monitoring capabilities due to alterations in instrumentation, data analysis, or programs are presented

  7. Experimental study on thermal-hydraulic for thermal striping phenomena. Results of temperature and velocity measurement among parallel triple jets

    International Nuclear Information System (INIS)

    Miyakoshi, Hiroyuki; Kimura, Nobuyuki; Kamide, Hideki; Miyake, Yasuhiro

    2003-03-01

    A quantitative evaluation on thermal striping, in which temperature fluctuation due to convective mixing among jets causes thermal fatigue in structural components, is of importance for structural integrity and also reactor safety. The treasonable and safety design could be approved by taking account of decay of temperature fluctuation in fluid, during heat transfer from fluid to structure surface and thermal conduction in the structure. In this study, water experiment was performed for vertical and parallel triple jets along wall, those are cold jet in the center and hot jets on both sides. The local temperature and velocity were measured by movable thermocouples and particle image velocimetry (PIV). The both hot jets flowed leaning to the cold jet. The lean of the jets increased as the jets approached the wall. So the convective mixing region among the jets was shifted upstream near the wall. Temperature fluctuation intensity was dependent of the distance from the wall. Under isovelocity condition, prominent frequency component was observed in the power spectrum density of the temperature fluctuation at the furthest position from the wall. The power at the prominent component decreased as the jets approached the wall. Under non-isovelocity condition, on the other hand, the power spectrum density of temperature fluctuation was independent of the distance from the wall. Comparison of the second moment between of velocity PIV and laser Doppler velocimetry showed that the PIV system had high measurement accuracy. Under non-isovelocity condition, the normal components in the second-order moments of fluctuation were smaller than those under isovelocity condition. Normal components in the second-order moments in turbulence was dependent of the distance from the wall. (author)

  8. Instruments used to measure or check α, β, γ activity and neutron emission in the course of processing ore or irradiated fuel

    International Nuclear Information System (INIS)

    Blanc, A.; Brunet, M.; Kermagoret, M.; Labeyrie, J.; Roux, G.; Vasseur, J.; Weil, J.

    1959-01-01

    One of the methods checking ores in the course of treatment is the rapid quantitative determination of thorium. This measurement is carried out by means of a scintillation instrument which shows the β and α coincidences of ThC and ThC'. The treatment of irradiated fuel is accompanied by a large number of radioactive checks relative to the performance of the fixation and elution operations of uranium in the ion exchangers, to the concentration of radioactivity of effluent sent from the plant into watercourses. The operations of fixation and elution of the uranium are checked automatically by an instrument which takes a sample of 5 cm 3 of solution, evaporates it and measures its activity every 10 or 20 minutes. Plutonium concentrations are measured: - in the presence of strong β γ activities, by means of rotating cylinder detectors; - in the presence of weak β γ activities, by means of α detectors scanning a constant level liquid surface; - by means of fission chambers relatively insensitive to γ. Fission product concentrations are measured by chambers, counters or scintillators, according to the amount of γ activity present. Finally, the activity of effluent to be emptied into watercourses is checked by means of a scintillation instrument, which measures the α activity on the one hand, and on the other hand the β γ activity of residue from a 100 cm 3 sample taken and evaporated in 20 minutes. (author) [fr

  9. A measurement instrument for bone mineral content of adult and children

    International Nuclear Information System (INIS)

    Liu Shaofang

    1996-01-01

    The γ radiation source was used in bone mineral content measurement analysis of adult and children and a new instrument is developed successfully. It's precision is +2%. The advantage of this instrument is light, cheap and reliable. It can be used widely in medical science and clinic for diagnosis on certain diseases and research work

  10. WISM - A Wideband Instrument for Snow Measurement: Past Accomplishments, Current Status, and Path Forward

    Science.gov (United States)

    Bonds, Quenton; Racette, Paul; Durham, Tim (Principal Investigator)

    2016-01-01

    Presented are the prior accomplishments, current status and path forward for GSFC's Wideband Instrument for Snow Measurement (WISM). This work is a high level overview of the project, presented via Webinar to the IEEE young professionals.

  11. Aerodynamic levitator furnace for measuring thermophysical properties of refractory liquids.

    Science.gov (United States)

    Langstaff, D; Gunn, M; Greaves, G N; Marsing, A; Kargl, F

    2013-12-01

    The development of novel contactless aerodynamic laser heated levitation techniques is reported that enable thermophysical properties of refractory liquids to be measured in situ in the solid, liquid, and supercooled liquid state and demonstrated here for alumina. Starting with polished crystalline ruby spheres, we show how, by accurately measuring the changing radius, the known density in the solid state can be reproduced from room temperature to the melting point at 2323 K. Once molten, by coupling the floating liquid drop to acoustic oscillations via the levitating gas, the mechanical resonance and damping of the liquid can be measured precisely with high-speed high-resolution shadow cast imaging. The resonance frequency relates to the surface tension, the decay constant to the viscosity, and the ellipsoidal size and shape of the levitating drop to the density. This unique instrumentation enables these related thermophysical properties to be recorded in situ over the entire liquid and supercooled range of alumina, from the boiling point at 3240 K, until spontaneous crystallization occurs around 1860 K, almost 500 below the melting point. We believe that the utility that this unique instrumentation provides will be applicable to studying these important properties in many other high temperature liquids.

  12. An Instrument for the Measurement of Parental Authority Prototypes.

    Science.gov (United States)

    Buri, John R.

    Baumrind (1971) proposed three distinct patterns of parental authority (permissiveness, authoritarianism, and authoritativeness) and measured these parenting styles through interviews with parents and their children and through observations of parents interacting with their children. This study was undertaken to develop a readily-accessible,…

  13. Developing and validating an instrument for measuring mobile computing self-efficacy.

    Science.gov (United States)

    Wang, Yi-Shun; Wang, Hsiu-Yuan

    2008-08-01

    IT-related self-efficacy has been found to have a critical influence on system use. However, traditional measures of computer self-efficacy and Internet-related self-efficacy are perceived to be inapplicable in the context of mobile computing and commerce because they are targeted primarily at either desktop computer or wire-based technology contexts. Based on previous research, this study develops and validates a multidimensional instrument for measuring mobile computing self-efficacy (MCSE). This empirically validated instrument will be useful to researchers in developing and testing the theories of mobile user behavior, and to practitioners in assessing the mobile computing self-efficacy of users and promoting the use of mobile commerce systems.

  14. Mechanical Properties of the Surface Material of Comet 67P/Churyumov-Gerasimenko Measured By the Casse Instrument Onboard the Philae Lander

    Science.gov (United States)

    Knapmeyer, M.; Fischer, H. H.; Seidensticker, K. J.; Arnold, W.; Faber, C.; Möhlmann, D.; Thiel, K.

    2014-12-01

    Satellite remote sensing of ocean color is a critical tool for assessing the productivity of marine ecosystems and monitoring changes resulting from climatic or environmental influences. Yet water-leaving radiance comprises less than 10% of the signal measured from space, making correction for absorption and scattering by the intervening atmosphere imperative. Traditional ocean color retrieval algorithms utilize a standard set of aerosol models and the assumption of negligible water-leaving radiance in the near-infrared. Modern improvements have been developed to handle absorbing aerosols such as urban particulates in coastal areas and transported desert dust over the open ocean, where ocean fertilization can impact biological productivity at the base of the marine food chain. Even so, imperfect knowledge of the absorbing aerosol optical properties or their height distribution results in well-documented sources of error. In the UV, the problem of UV-enhanced absorption and nonsphericity of certain aerosol types are amplified due to the increased Rayleigh and aerosol optical depth, especially at off-nadir view angles. Multi-angle spectro-polarimetric measurements have been advocated as an additional tool to better understand and retrieve the aerosol properties needed for atmospheric correction for ocean color retrievals. The central concern of the work to be described is the assessment of the effects of absorbing aerosol properties on water leaving radiance measurement uncertainty by neglecting UV-enhanced absorption of carbonaceous particles and by not accounting for dust nonsphericity. In addition, we evaluate the polarimetric sensitivity of absorbing aerosol properties in light of measurement uncertainties achievable for the next generation of multi-angle polarimetric imaging instruments, and demonstrate advantages and disadvantages of wavelength selection in the UV/VNIR range. The phase matrices for the spherical smoke particles were calculated using a standard

  15. Equation-of-state for fluids at high densities-hydrogen isotope measurements and thermodynamic derivations

    International Nuclear Information System (INIS)

    Liebenberg, D.H.; Mills, R.L.; Bronson, J.C.

    1977-01-01

    Hydrogen isotopes play an important role in energy technologies, in particular, the compression to high densities for initiation of controlled thermonuclear fusion energy. At high densities the properties of the compressed hydrogen isotopes depart drastically from ideal thermodynamic predictions. The measurement of accurate data including the author's own recent measurements of n-H 2 and n-D 2 in the range 75 to 300 K and 0.2 to 2.0 GPa (2 to 20 kbar) is reviewed. An equation-of-state of the Benedict type is fit to these data with a double-process least-squares computer program. The results are reviewed and compared with existing data and with a variety of theoretical work reported for fluid hydrogens. A new heuristic correlation is presented for simplicity in predicting volumes and sound velocity at high pressures. 9 figures, 1 table

  16. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column.

    Science.gov (United States)

    Rohlmann, Antonius; Gabel, Udo; Graichen, Friedmar; Bender, Alwina; Bergmann, Georg

    2007-06-01

    Realistic loads on a spinal implant are required among others for optimization of implant design and preclinical testing. In addition, such data may help to choose the optimal physiotherapy program for patients with such an implant and to evaluate the efficacy of aids like braces or crutches. Presently, no implant is available that can measure loads in the anterior spinal column during activities of daily life. Therefore, an implant instrumented for in vivo load measurement was developed for vertebral body replacement. The aim of this paper is to describe in detail a telemeterized implant that measures forces and moments acting on it. Six load sensors, a nine-channel telemetry unit and a coil for inductive power supply of the electronic circuits were integrated into a modified vertebral body replacement (Synex). The instrumented part of the implant is hermetically sealed. Patients are videotaped during measurements, and implant loads are displayed on and off line. The average accuracy of load measurement is better than 2% for force and 5% for moment components with reference to the maximum value of 3000 N and 20 Nm, respectively. The measuring implant described here will provide additional information on spinal loads.

  17. Effect of asynchrony on numerical simulations of fluid flow phenomena

    Science.gov (United States)

    Konduri, Aditya; Mahoney, Bryan; Donzis, Diego

    2015-11-01

    Designing scalable CFD codes on massively parallel computers is a challenge. This is mainly due to the large number of communications between processing elements (PEs) and their synchronization, leading to idling of PEs. Indeed, communication will likely be the bottleneck in the scalability of codes on Exascale machines. Our recent work on asynchronous computing for PDEs based on finite-differences has shown that it is possible to relax synchronization between PEs at a mathematical level. Computations then proceed regardless of the status of communication, reducing the idle time of PEs and improving the scalability. However, accuracy of the schemes is greatly affected. We have proposed asynchrony-tolerant (AT) schemes to address this issue. In this work, we study the effect of asynchrony on the solution of fluid flow problems using standard and AT schemes. We show that asynchrony creates additional scales with low energy content. The specific wavenumbers affected can be shown to be due to two distinct effects: the randomness in the arrival of messages and the corresponding switching between schemes. Understanding these errors allow us to effectively control them, rendering the method's feasibility in solving turbulent flows at realistic conditions on future computing systems.

  18. Rheological properties of PHPA polymer support fluids

    OpenAIRE

    Lam, Carlos; Martin, P J; Jefferis, S A

    2015-01-01

    Synthetic polymer fluids are becoming a popular replacement for bentonite slurries to support excavations for deep foundation elements. However, the rheological properties of the polymer fluids used in excavation support have not been studied in detail, and there is currently confusion about the choice of mathematical models for this type of fluid. To advance the current state of knowledge, a laboratory study has been performed to investigate the steady-shear viscosity and transient viscoelas...

  19. Measurement properties of patient reported outcome measures for spondyloarthritis: A systematic review.

    Science.gov (United States)

    Png, Kelly; Kwan, Yu Heng; Leung, Ying Ying; Phang, Jie Kie; Lau, Jia Qi; Lim, Ka Keat; Chew, Eng Hui; Low, Lian Leng; Tan, Chuen Seng; Thumboo, Julian; Fong, Warren; Østbye, Truls

    2018-03-21

    This systematic review aimed to identify studies investigating measurement properties of patient reported outcome measures (PROMs) for spondyloarthritis (SpA), and to evaluate their methodological quality and level of evidence relating to the measurement properties of PROMs. This systematic review was guided by the preferred reporting items for systematic review and meta-analysis (PRISMA). Articles published before 30 June 2017 were retrieved from PubMed ® , Embase ® , and PsychINFO ® (Ovid). Methodological quality and level of evidence were evaluated according to recommendations from the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). We identified 60 unique PROMs from 125 studies in 39 countries. Twenty-one PROMs were validated for two or more SpA subtypes. The literature examined hypothesis testing (82.4%) most frequently followed by reliability (60.0%). A percentage of 77.7% and 42.7% of studies that assessed PROMs for hypothesis testing and reliability, respectively had "fair" or better methodological quality. Among the PROMs identified, 41.7% were studied in ankylosing spondylitis (AS) only and 23.3% were studied in psoriatic arthritis (PsA) only. The more extensively assessed PROMs included the ankylosing spondylitis quality of life (ASQoL) and bath ankylosing spondylitis functional index (BASFI) for ankylosing spondylitis, and the psoriatic arthritis quality of life questionnaire (VITACORA-19) for psoriatic arthritis. This study identified 60 unique PROMs through a systematic review and synthesized evidence of the measurement properties of the PROMs. There is a lack of validation of PROMs for use across SpA subtypes. Future studies may consider validating PROMs for use across different SpA subtypes. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Discussion of heat transfer phenomena in fluids at supercritical pressure with the aid of CFD models

    International Nuclear Information System (INIS)

    Sharabi, Medhat; Ambrosini, Walter

    2009-01-01

    The paper discusses heat transfer enhancement and deterioration phenomena observed in experimental data for fluids at supercritical pressure. The results obtained by the application of various CFD turbulence models in the prediction of experimental data for water and carbon dioxide flowing in circular tubes are firstly described. On this basis, the capabilities of the addressed models in predicting the observed phenomena are shortly discussed. Then, the analysis focuses on further results obtained by a low-Reynolds number k - ε model addressing one of the considered experimental apparatuses by changing the operating conditions. In particular, the usual imposed heat flux boundary condition is changed to assigned wall temperature, in order to highlight effects otherwise impossible to point out. The obtained results, supported by considerations drawn from experimental information, allow comparing the trends observed for heat transfer deterioration at supercritical pressure with those typical of the thermal crisis in boiling systems, clarifying old concepts of similarity among them

  1. Rheological Properties of Quasi-2D Fluids in Microgravity

    Science.gov (United States)

    Stannarius, Ralf; Trittel, Torsten; Eremin, Alexey; Harth, Kirsten; Clark, Noel; Maclennan, Joseph; Glaser, Matthew; Park, Cheol; Hall, Nancy; Tin, Padetha

    2015-01-01

    In recent years, research on complex fluids and fluids in restricted geometries has attracted much attention in the scientific community. This can be attributed not only to the development of novel materials based on complex fluids but also to a variety of important physical phenomena which have barely been explored. One example is the behavior of membranes and thin fluid films, which can be described by two-dimensional (2D) rheology behavior that is quite different from 3D fluids. In this study, we have investigated the rheological properties of freely suspended films of a thermotropic liquid crystal in microgravity experiments. This model system mimics isotropic and anisotropic quasi 2D fluids [46]. We use inkjet printing technology to dispense small droplets (inclusions) onto the film surface. The motion of these inclusions provides information on the rheological properties of the films and allows the study of a variety of flow instabilities. Flat films have been investigated on a sub-orbital rocket flight and curved films (bubbles) have been studied in the ISS project OASIS. Microgravity is essential when the films are curved in order to avoid sedimentation. The experiments yield the mobility of the droplets in the films as well as the mutual mobility of pairs of particles. Experimental results will be presented for 2D-isotropic (smectic-A) and 2D-nematic (smectic-C) phases.

  2. Progress in the specification of optical instruments for the measurement of surface form and texture

    Science.gov (United States)

    de Groot, Peter J.

    2014-05-01

    Specifications for confocal microscopes, optical interferometers and other methods of measuring areal surface topography can be confusing and misleading. The emerging ISO 25178 standards, together with the established international vocabulary of metrology, provide a foundation for improved specifications for 3D surface metrology instrumentation. The approach in this paper links instrument specifications to metrological characteristics that can influence a measurement, using consistent definitions of terms, and reference to verification procedures.

  3. Replication unreliability in psychology: elusive phenomena or elusive statistical power?

    Directory of Open Access Journals (Sweden)

    Patrizio E Tressoldi

    2012-07-01

    Full Text Available The focus of this paper is to analyse whether the unreliability of results related to certain controversial psychological phenomena may be a consequence of their low statistical power.Applying the Null Hypothesis Statistical Testing (NHST, still the widest used statistical approach, unreliability derives from the failure to refute the null hypothesis, in particular when exact or quasi-exact replications of experiments are carried out.Taking as example the results of meta-analyses related to four different controversial phenomena, subliminal semantic priming, incubation effect for problem solving, unconscious thought theory, and non-local perception, it was found that, except for semantic priming on categorization, the statistical power to detect the expected effect size of the typical study, is low or very low.The low power in most studies undermines the use of NHST to study phenomena with moderate or low effect sizes.We conclude by providing some suggestions on how to increase the statistical power or use different statistical approaches to help discriminate whether the results obtained may or may not be used to support or to refute the reality of a phenomenon with small effect size.

  4. ALADIN: an atmospheric laser Doppler wind lidar instrument for wind velocity measurements from space

    Science.gov (United States)

    Krawczyk, R.; Ghibaudo, JB.; Labandibar, JY.; Willetts, D.; Vaughan, M.; Pearson, G.; Harris, M.; Flamant, P. H.; Salamitou, P.; Dabas, A.; Charasse, R.; Midavaine, T.; Royer, M.; Heimel, H.

    2018-04-01

    This paper, "ALADIN: an atmospheric laser Doppler wind lidar instrument for wind velocity measurements from space," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  5. Cake properties in ultrafiltration of TiO2 fine particles combined with HA: in situ measurement of cake thickness by fluid dynamic gauging and CFD calculation of imposed shear stress for cake controlling.

    Science.gov (United States)

    Du, Xing; Qu, Fangshu; Liang, Heng; Li, Kai; Chang, Haiqing; Li, Guibai

    2016-05-01

    In this study, the cake buildup of TiO2 fine particles in the presence of humid acid (HA) and cake layer controlling during ultrafiltration (UF) were investigated. Specifically, we measured the cake thickness using fluid dynamic gauging (FDG) method under various solution conditions, including TiO2 concentration (0.1-0.5 g/L), HA concentration (0-5 mg/L, total organic carbon (TOC)), and pH values (e.g., 4, 6 and 10), and calculated the shear stress distribution induced by stirring using computational fluid dynamics (CFD) to analyze the cake layer controlling conditions, including the operation flux (50-200 L m(-2) h(-1)) and TiO2 concentration (0.1-0.5 g/L). It was found that lower TiO2/HA concentration ratio could lead to exceedingly severe membrane fouling because of the formation of a relatively denser cake layer by filling the voids of cake layer with HA, and pH was essential for cake layer formation owing to the net repulsion between particles. Additionally, it was observed that shear stress was rewarding for mitigating cake growth under lower operation flux as a result of sufficient back-transport forces, and exhibited an excellent performance on cake layer controlling in lower TiO2 concentrations due to slight interaction forces on the vicinity of membrane.

  6. Convection measurement package for space processing sounding rocket flights. [low gravity manufacturing - fluid dynamics

    Science.gov (United States)

    Spradley, L. W.

    1975-01-01

    The effects on heated fluids of nonconstant accelerations, rocket vibrations, and spin rates, was studied. A system is discussed which can determine the influence of the convective effects on fluid experiments. The general suitability of sounding rockets for performing these experiments is treated. An analytical investigation of convection in an enclosure which is heated in low gravity is examined. The gravitational body force was taken as a time-varying function using anticipated sounding rocket accelerations, since accelerometer flight data were not available. A computer program was used to calculate the flow rates and heat transfer in fluids with geometries and boundary conditions typical of space processing configurations. Results of the analytical investigation identify the configurations, fluids and boundary values which are most suitable for measuring the convective environment of sounding rockets. A short description of fabricated fluid cells and the convection measurement package is given. Photographs are included.

  7. The MSA: An Instrument for Measuring Motivation to Study Abroad

    Science.gov (United States)

    Anderson, Philip H.; Lawton, Leigh

    2015-01-01

    While there is a growing body of research on study abroad programs, as Li, Olson, and Frieze (2013) observed, "Research on study abroad has primarily focused on the effects or outcomes of study abroad participation on the students involved in these programs…Very limited attention has been devoted to studying factors affecting students'…

  8. Development of software in LabVIEW for measurement of transport properties of high Tc superconductors

    International Nuclear Information System (INIS)

    Reilly, D.; Savvides, N.

    1996-01-01

    Full text: The gathering of data and their analysis are vital processes in experiments. We have used LabVIEW (National Instruments) to develop programs to measure transport properties of high - T c superconductors, eg. resistivity, ac susceptibility, I-V characteristics. Our systems make use of GPIB (IEEE - 488.2) programmable instruments and a personal computer. LabVIEW is a graphical programming system for instrument control and data acquisition, data analysis and presentation. A key feature of LabVIEW is the ability to graphically assemble software modules or virtual instruments (VIs) and 'wire' them together. In this paper we describe the development of several programs and will offer advice to colleagues wanting to explore LabVIEW

  9. Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)

    Science.gov (United States)

    Durham, Timothy E.; Vanhille, Kenneth J.; Trent, Christopher R.; Lambert, Kevin M.; Miranda, Felix A.

    2015-01-01

    This poster describes the implementation of a 6x6 element, dual linear polarized array with beamformer that operates from about 8-40 GHz. It is implemented using a relatively new multi-layer microfabrication process. The beamformer includes baluns that feed dual-polarized differential antenna elements and reactive splitters that cover the full frequency range of operation. This fixed beam array (FBA) serves as the feed for a multi-band instrument designed to measure snow water equivalent (SWE) from an airborne platform known as the Wideband Instrument for Snow Measurements (WISM).

  10. Measurement of the levels of homocysteine in the patients with gynecological malignant tumors before and during treatment with chemotherapy and/or radiotherapy like predictor of thrombosis phenomena

    International Nuclear Information System (INIS)

    Landaverde Recinos, Denis

    2005-01-01

    A prospective study of incidence was realized investigating if an increase of the levels of plasmatic homocysteine in patients with malignant gynecological tumors exists before and during the treatment with chemotherapy and/or radiotherapy and if this increase is correlated with deep poisonous thrombosis. In addition, it was correlated if the increase of the homocysteine is also accompanied with protein elevation C and S as well as with speed of erythrosedimentation (VES) and protein C reactive (PCR). The study covered to 25 feminine patients in the Hospital San Juan de Dios, those that were observed by a period of three months. It concludes that the time of observation is very short to determine if the initial increase of homocysteinemia in patients with gynecological malignant tumors could be related or not with an increase in the rate of deep poisonous thrombosis in this group of patients. Nevertheless, this study obtained not to demonstrate that the increase of the levels of homocysteinemia elevates the probability of thrombotic phenomena in patients with gynecological cancer before and during the treatment with chemotherapy and/or radiotherapy. (author) [es

  11. Measuring instruments of corporate reputation

    Directory of Open Access Journals (Sweden)

    Damir Grgić

    2008-12-01

    Full Text Available The subject of this paper is focused on the instruments for the measurement of corporate reputation. Recent research of the elements which influence the success of a company shows a growing interest in intangible values. Corporate reputation itself has been identified as one of the key intangible assets which create the company’s added value. Understanding of the importance of corporate reputation has been determined as a significant component of the company’s competitiveness, that is, of its competitive edge. Reputation is a normal part of our life and an integral part of our society. Our interest in the honesty and integrity of others is firmly established in all cultures and nowadays the focus of this interest is switching increasingly on companies. Corporate reputation can be acquired by means of strong, well-developed strategies, which are crucial for the opinion of stakeholders regarding future stability and competitive sustainability of the company. On the other hand, it should be emphasized that in order to manage it, corporate reputation has to be measured first. However, although the concept of corporate reputation is universally accepted and its significance has been recognized especially in the last two decades, the process of its measurement is still at an early stage and there is no universally accepted instrument for its measurement. Therefore, the author of this paper gives an overview of the instruments used for the measurement of corporate reputation which have gained a foothold through former practical usage.

  12. Methods and apparatus for measurement of electronic properties of geological formations through borehole casing

    Science.gov (United States)

    Vail, W.B. III.

    1989-11-21

    Methods and apparatus are provided for measuring electronic properties of geological formations and cement layers adjacent to cased boreholes including resistivities, polarization phenomena and dielectric constants. Current is passed from an electrode in electrical contact with the interior of the borehole casing to an electrode on the surface of the earth. At least three voltage measuring electrodes in electrical contact with the interior of the casing measure the voltage at various points thereon. The voltage differences between discrete pairs of the voltage measuring electrodes provide a measurement of differential current conducted into formation in the vicinity of those electrodes. These measurements facilitate calculation of the resistivities of the adjacent geological formations as well as an indication of whether cement is present. Measurements of the differential voltage response to transient currents provide a measurement of the polarization phenomena in formation as well as the capacitance of the casing in contact with the formation which is useful for determining whether oil and gas are present. Lithological characteristics of the formation such as the presence or absence of clay can also be determined. A calibration procedure is provided for minimizing errors induced by variations in the casing. The device also may be placed within the pipe attached to a drill bit while drilling open holes. 48 figs.

  13. Fluid mechanics phenomena in microgravity; ASME Winter Annual Meeting, Anaheim, CA, Nov. 8-13, 1992

    Science.gov (United States)

    Siginer, Dennis A. (Editor); Weislogel, Mark M. (Editor)

    1992-01-01

    This paper is the first in a series of symposia presenting research activity in microgravity fluid mechanics. General topics addressed include two-phase flow and transport phenomena, thermo-capillary flow, and interfacial stability. Papers present mathmatical models of fluid dynamics in the microgravity environment. Applications suggested include space manufacturing and storage of liquids in low gravity.

  14. ORNL instrumentation performance for Slab Core Test Facility (SCTF)-Core I Reflood Test Facility

    International Nuclear Information System (INIS)

    Hardy, J.E.; Hess, R.A.; Hylton, J.O.

    1983-11-01

    Instrumentation was developed for making measurements in experimental refill-reflood test facilities. These unique instrumentation systems were designed to survive the severe environmental conditions that exist during a simulated pressurized water reactor loss-of-coolant accident (LOCA). Measurement of in-vessel fluid phenomena such as two-phase flow velocity and void fraction and film thickness and film velocity are required for better understanding of reactor behavior during LOCAs. The Advanced Instrumentation for Reflood Studies (AIRS) Program fabricated and delivered instrumentation systems and data reduction software algorithms that allowed the above measurements to be made. Data produced by AIRS sensors during three experimental runs in the Japanese Slab Core Test Facility are presented. Although many of the sensors failed before any useful data could be obtained, the remaining probes gave encouraging and useful results. These results are the first of their kind produced during simulated refill-reflood stage of a LOCA near actual thermohydrodynamic conditions

  15. Construction and Validation of a Measurement Instrument for Attitudes towards Teamwork

    Science.gov (United States)

    Mendo-Lázaro, Santiago; Polo-del-Río, María I.; Iglesias-Gallego, Damián; Felipe-Castaño, Elena; León-del-Barco, Benito

    2017-01-01

    Cooperative, collaborative learning and other forms of group learning methods are increasingly used in classrooms. Knowing students’ attitudes toward teamwork has great value since they influence the students’ learning results as well as their social development. So it is necessary to have robust instruments to provide a better understanding of these attitudes and preferences concerning teamwork. Such instruments also help to identify the factors that promote positive or negative attitudes within the context of group activities. Using a sample of 750 first and second year university students studying a degree in Kindergarten, Primary and Social Education, an instrument measuring attitudes toward team learning has been developed. Two distinct factors were obtained through various factorial analyses and structural equations: Academic attitudes and Social and emotional attitudes. Our study reveals that the instrument is both valid and reliable. Its application is both simple and fast and it has important implications for planning teaching and learning activities that contribute to an improvement in attitudes as well as the practice of teaching in the context of learning through teamwork. PMID:28676775

  16. Construction and Validation of a Measurement Instrument for Attitudes towards Teamwork

    Directory of Open Access Journals (Sweden)

    Santiago Mendo-Lázaro

    2017-06-01

    Full Text Available Cooperative, collaborative learning and other forms of group learning methods are increasingly used in classrooms. Knowing students’ attitudes toward teamwork has great value since they influence the students’ learning results as well as their social development. So it is necessary to have robust instruments to provide a better understanding of these attitudes and preferences concerning teamwork. Such instruments also help to identify the factors that promote positive or negative attitudes within the context of group activities. Using a sample of 750 first and second year university students studying a degree in Kindergarten, Primary and Social Education, an instrument measuring attitudes toward team learning has been developed. Two distinct factors were obtained through various factorial analyses and structural equations: Academic attitudes and Social and emotional attitudes. Our study reveals that the instrument is both valid and reliable. Its application is both simple and fast and it has important implications for planning teaching and learning activities that contribute to an improvement in attitudes as well as the practice of teaching in the context of learning through teamwork.

  17. The 2010 calibration campaign for radon gas measuring instruments at PSI

    International Nuclear Information System (INIS)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2011-01-01

    Twenty radon measurement services or the respective analytical laboratories participated in the 2010 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) from August 27 th to August 31 st , 2010 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (track-etch, electronic and electret) and instruments (ionisation chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 595 Bq m -3 leading to a radon gas exposure of 57 kBq h m -3 . The exposure of 57 kBq h m -3 was close to the lower value of the measuring range defined in the Radon Measurement Ordinance ('Radon-Messmittelverordnung'). (authors)

  18. 093 Measurement Instrument for Determinants of Innovations (MIDI)

    NARCIS (Netherlands)

    Fleuren, M.; Paulussen, T.; van Dommelen, P.; van Buuren, S.

    2013-01-01

    BackgroundIn 2002, we developed a list of 60 potential relevant determinants that are critical for a successful implementation of innovations in health care, such as guidelines. This list was a result of a review of empirical studies and a Delphi study among implementation experts. Since 2002, we

  19. Dependence of cycle optimal configuration for closed gas turbines on thermodynamic properties of working fluids

    International Nuclear Information System (INIS)

    Andryushchenko, A.I.; Dubinin, A.B.; Krylov, E.E.

    1988-01-01

    The problem of choice of working fluids for NPP closed gas turbines (CGT) is discussed. Thermostable in the working temperature range, chemically inert relatively to structural materials, fire- and explosion - proof substances, radiation-resistant and having satisfactory neutron-physical characteristics are used as the working fluids. Final choice of a gas as a working fluid is exercised based on technical and economic comparison of different variants at optimum thermodynamic cycle and parameters for each gas. The character and degree of the effect of thermodynamic properties of gases on configuration of reference cycles of regenerative CGT are determined. It is established that efficiency and optimum parameters in nodal points of the reference cycle are specified by the degree of removing the compression processes from the critical point. Practical importance of the obtained results presupposes the possibility of rapid estimation of the efficiency of using a gas without multiparametric optimization

  20. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    OpenAIRE

    Schans, van der, C.P.; Zijlstra, W.; Regterschot, G.R.H.; Krijnen, W.P.; Douma, K.W.; Slager, G.E.C.

    2016-01-01

    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various d...

  1. EDITORIAL: Advances in Measurement Technology and Intelligent Instruments for Production Engineering

    Science.gov (United States)

    Gao, Wei; Takaya, Yasuhiro; Gao, Yongsheng; Krystek, Michael

    2008-08-01

    . Neuschaefer-Rube et al, also from PTB, present procedures and standards to test tactile and optical microsensors and micro-computed tomography systems, which are similar to the established tests for classical coordinate measuring machines and assess local and global sensor characteristics. The last three papers are related to micro/nano-metrology and intelligent instrumentation. Jiang et al from Tohoku University describe the fabrication of piezoresistive nanocantilevers for ultra-sensitive force detection by using spin-out diffusion, EB lithography and FAB etching, respectively. Y-C Liu et al from National Taiwan University develop an economical and highly sensitive optical accelerometer using a commercial optical pickup head. Michihata et al from Osaka University experimentally investigate the positioning sensing property and accuracy of a laser trapping probe for a nano-coordinate measuring machine. As guest editors, we believe that this special feature presents the newest information on advances in measurement technology and intelligent instruments from basic research to applied systems for Production Engineering. We would like to thank all the authors for their great contributions to this special feature and the referees for their careful reviews of the papers. We would also like to express our thanks and appreciation to Professor P Hauptmann, Editor-in-Chief of MST, for his kind offer to publish selected ISMTII 2007 papers in MST, and to the publishing staff of MST for their dedicated efforts that have made this special feature possible.

  2. A measuring instrument for telecommunication and application technology

    International Nuclear Information System (INIS)

    Baek, Ju Gi; Lee, Gi Hack

    2006-08-01

    This is a guide book for an engineer in IT. It is divided two parts. The first part is composed with basic equipment such as power supply, multimeter, LCR-meter, function generator, an oscilloscope, frequency counter, level meter and an attenuator. The second part contains RF signal generator, spectrum analyzer and logic analyzer. This part introduces HC-G220S, vector signal generator, Agilent spectrum analyzer and HC 7802 model, 54620A logic analyzer and TA4000 model.

  3. Brachial cuff measurements of blood pressure during passive leg raising for fluid responsiveness prediction.

    Science.gov (United States)

    Lakhal, K; Ehrmann, S; Benzekri-Lefèvre, D; Runge, I; Legras, A; Dequin, P-F; Mercier, E; Wolff, M; Régnier, B; Boulain, T

    2012-05-01

    The passive leg raising maneuver (PLR) for fluid responsiveness testing relies on cardiac output (CO) measurements or invasive measurements of arterial pressure (AP) whereas the initial hemodynamic management during shock is often based solely on brachial cuff measurements. We assessed PLR-induced changes in noninvasive oscillometric readings to predict fluid responsiveness. Multicentre interventional study. In ICU sedated patients with circulatory failure, AP (invasive and noninvasive readings) and CO measurements were performed before, during PLR (trunk supine, not modified) and after 500-mL volume expansion. Areas under the ROC curves (AUC) were determined for fluid responsiveness (>10% volume expansion-induced increase in CO) prediction. In 112 patients (19% with arrhythmia), changes in noninvasive systolic AP during PLR (noninvasiveΔ(PLR)SAP) only predicted fluid responsiveness (cutoff 17%, n=21, positive likelihood ratio [LR] of 26 [18-38]), not unresponsiveness. If PLR-induced change in central venous pressure (CVP) was at least of 2 mm Hg (n=60), suggesting that PLR succeeded in altering cardiac preload, noninvasiveΔ(PLR)SAP performance was good: AUC of 0.94 [0.85-0.98], positive and negative LRs of 5.7 [4.6-6.8] and 0.07 [0.009-0.5], respectively, for a cutoff of 9%. Of note, invasive AP-derived indices did not outperform noninvasiveΔ(PLR)SAP. Regardless of CVP (i.e., during "blind PLR"), noninvasiveΔ(PLR)SAP more than 17% reliably identified fluid responders. During "CVP-guided PLR", in case of sufficient change in CVP, noninvasiveΔ(PLR)SAP performed better (cutoff of 9%). These findings, in sedated patients who had already undergone volume expansion and/or catecholamines, have to be verified during the early phase of circulatory failure (before an arterial line and/or a CO measuring device is placed). Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  4. Development of an instrument for measuring moisture deep into solid materials

    International Nuclear Information System (INIS)

    Westin, R.; Walletun, H.

    1993-01-01

    It is of value in some applications to be able to detect humidity rather deep into a solid material, for example when determining the moisture content in the frame of buildings, in insulation or in biofuels. Common to these measurement problems is that it is difficult to measure moisture in the bulk of a solid, in contrast to the surface layers. In this report is described the principle and the functioning of an instrument to measure moisture at larger depths than other instruments that are available today. It is intended for use primarily on solid materials, not on gases or liquids. Field experience is also reported here. The principle of the measuring technique is nuclear: we have utilized the ability of hydrogen atoms to moderate (or brake) high energy neutrons. If there is hydrogen in the sample, fast neutrons will interact with the hydrogen atoms and one may detect and count low energy, so called thermal neutrons. The intensity of the slow neutron flux is proportional to the water content, if one assumes that hydrogen atoms are water, i.e. moisture

  5. Psychometric properties of assessment instruments for autism spectrum disorder: a systematic review of Brazilian studies

    Directory of Open Access Journals (Sweden)

    Bárbara Backes

    2014-07-01

    Full Text Available Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.

  6. Measurement Properties of Indirect Assessment Methods for Functional Behavioral Assessment: A Review of Research

    Science.gov (United States)

    Floyd, Randy G.; Phaneuf, Robin L.; Wilczynski, Susan M.

    2005-01-01

    Indirect assessment instruments used during functional behavioral assessment, such as rating scales, interviews, and self-report instruments, represent the least intrusive techniques for acquiring information about the function of problem behavior. This article provides criteria for examining the measurement properties of these instruments…

  7. Vapour-liquid equilibrium properties for two- and three-dimensional Lennard-Jones fluids from equations of state

    International Nuclear Information System (INIS)

    Mulero, A.; Cuadros, F; Faundez, C.A.

    1999-01-01

    Vapour-liquid equilibrium properties for both three- and two-dimensional Lennard-Jones fluids were obtained using simple cubic-in-density equations of state proposed by the authors. Results were compared with those obtained by other workers from computer simulations and also with results given by other more complex semi-theoretical or semi-empirical equations of state. In the three-dimensional case good agreement is found for all properties and all temperatures. In the two-dimensional case only the coexistence densities were compared, producing good agreement for low temperatures only. The present work is the first to give numerical data for the vapour-liquid equilibrium properties of Lennard-Jones fluids calculated from equations of state. Copyright (1999) CSIRO Australia

  8. Airflow resistivity instrument for in situ measurement on the earth's ground surface

    Science.gov (United States)

    Zuckerwar, A. J.

    1983-01-01

    An airflow resistivity instrument features a novel specimen holder, especially designed for in situ measurement on the earth's ground surface. This capability eliminates the disadvantages of prior intrusive instruments, which necessitate the removal of a test specimen from the ground. A prototype instrument can measure airflow resistivities in the range 10-5000 cgs rayl/cm, at specimen depths up to 15.24 cm (6 in.), and at differential pressures up to 2490.8 dyn sq cm (1 in. H2O) across the specimen. Because of the close relationship between flow resistivity and acoustic impedance, this instrument should prove useful in acoustical studies of the earth's ground surface. Results of airflow resistivity measurements on an uncultivated grass field for varying values of moisture content are presented.

  9. Measuring Instrument Constructs of Return Factors for Green Office Building Investments Variables Using Rasch Measurement Model

    Directory of Open Access Journals (Sweden)

    Isa Mona

    2016-01-01

    Full Text Available This paper is a preliminary study on rationalising green office building investments in Malaysia. The aim of this paper is attempt to introduce the application of Rasch measurement model analysis to determine the validity and reliability of each construct in the questionnaire. In achieving this objective, a questionnaire survey was developed consists of 6 sections and a total of 106 responses were received from various investors who own and lease office buildings in Kuala Lumpur. The Rasch Measurement analysis is used to measure the quality control of item constructs in the instrument by measuring the specific objectivity within the same dimension, to reduce ambiguous measures, and a realistic estimation of precision and implicit quality. The Rasch analysis consists of the summary statistics, item unidimensionality and item measures. A result shows the items and respondent (person reliability is at 0.91 and 0.95 respectively.

  10. Fluid Properties Measurements Using Wavelength Modulation Spectroscopy with First Harmonic Detection

    Science.gov (United States)

    Chen, Shin-Juh (Inventor); Silver, Joel A. (Inventor)

    2014-01-01

    An apparatus and method for monitoring gas velocity, temperature, and pressure in combustion systems and flow devices, in particular at inlets and isolators of scramjet engines. The invention employs wavelength modulation spectroscopy with first harmonic detection and without the need to scan the full absorption spectra.

  11. Studies of strength and rheological properties of clay-cement fluids

    Energy Technology Data Exchange (ETDEWEB)

    Salamatov, M A

    1979-01-01

    New principles are substantiated and formulated for studying the strength and elastic-plastic-viscous properties of clay-cement plugging fluids on series manufactured displacement instruments. A technique is presented and results are cited from studies of clay-cement plugging fluids of different composition at different stages of stabilization.

  12. Cavity Attenuated Phase Shift (CAPS) Method for Airborne Aerosol Light Extinction Measurement: Instrument Validation and First Results from Field Deployment

    Science.gov (United States)

    Petzold, A.; Perim de Faria, J.; Berg, M.; Bundke, U.; Freedman, A.

    2015-12-01

    Monitoring the direct impact of aerosol particles on climate requires the continuous measurement of aerosol optical parameters like the aerosol extinction coefficient on a regular basis. Remote sensing and ground-based networks are well in place (e.g., AERONET, ACTRIS), whereas the regular in situ measurement of vertical profiles of atmospheric aerosol optical properties remains still an important challenge in quantifying climate change. The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in situ observational data by using commercial passenger aircraft as measurement platform. However, scientific instrumentation for the measurement of atmospheric constituents requires major modifications before being deployable aboard in-service passenger aircraft. Recently, a compact and robust family of optical instruments based on the cavity attenuated phase shift (CAPS) technique has become available for measuring aerosol light extinction. While this technique was successfully deployed for ground-based atmospheric measurements under various conditions, its suitability for operation aboard aircraft in the free and upper free troposphere still has to be demonstrated. In this work, the modifications of a CAPS PMex instrument for measuring aerosol light extinction on aircraft, the results from subsequent laboratory tests for evaluating the modified instrument prototype, and first results from a field deployment aboard a research aircraft will be covered. In laboratory studies, the instrument showed excellent agreement (deviation CAPS PMex instrument response within 10% deviation. During the field deployment, aerosol extinction coefficients and associated aerosol size distributions have been measured and will be presented as comparison studies between measured and calculated data.

  13. Comparison of the mechanical properties of rotary instruments made of conventional nickel-titanium wire, M-wire, or nickel-titanium alloy in R-phase.

    Science.gov (United States)

    Lopes, Hélio P; Gambarra-Soares, Thaiane; Elias, Carlos N; Siqueira, José F; Inojosa, Inês F J; Lopes, Weber S P; Vieira, Victor T L

    2013-04-01

    This study compared the mechanical properties of endodontic instruments made of conventional nickel-titanium (NiTi) wire (K(3) and Revo-S SU), M-Wire (ProFile Vortex), or NiTi alloy in R-phase (K(3)XF). The test instruments were subjected to mechanical tests to evaluate resistance to bending (flexibility), cyclic fatigue, and torsional load in clockwise rotation. Data were statistically evaluated by the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. In the bending resistance test, flexibility decreased in the following order: K(3)XF > Revo-S SU > ProFile Vortex > K(3). The ranking in the fatigue resistance test was the following: K(3)XF > K(3) > ProFile Vortex > Revo-S SU. In the torsional assay, the angular deflection at failure decreased in the following order: K(3)XF > Revo-S SU > K(3) > ProFile Vortex. For the maximum torque values, the ranking was K(3) > K(3)XF > ProFile Vortex > Revo-S SU. The results showed that the K(3)XF instrument, which is made of NiTi alloy in R-phase, had the overall best performance in terms of flexibility, angular deflection at failure, and cyclic fatigue resistance. In addition to the alloy from which the instrument is manufactured, the design and dimensions are important determinants of the mechanical performance of endodontic instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. To IO-3 type instrument for measuring relative deviation of mean frequency

    International Nuclear Information System (INIS)

    Albats, Ya.Eh.; Bitite, Ya.A.; Ivanov, G.M.; Karpel'tseva, L.P.; Tesnavs, Eh.R.; Shuvtsan, Ya.V.

    1979-01-01

    A description is given of the 10-3 instrument intended for automatic measurement of a relative deviation of the pulse flow mean frequency from the preset value with digital presentation of measurement results, and also for the conversion of this relative deviation into an electric coded signal and in an analogue voltage signal. The 10-3 instrument comprises a master pulse generator, two preliminary scalers, two electronic switches, two storage pulse counters, control devices, a counter digital volume setter, a rewriting device, an internal storage, a digital display, and a digital-to-analog converter. The principle of the instrument operation consists in counting the pulses of measured and reference pulse flows by two storage counters. Basic performances of the instrument are given. The main advantage of the 10-3 instrument lies in the fact that it presents the results of measuring by a digital radioisotope instrument directly in physical units of the measured parameter, and that, in turn, obviates the necessity for additional mathematical operations when data processing [ru

  15. Fluid Physics Experiments onboard International Space Station: Through the Eyes of a Scientist.

    Science.gov (United States)

    Shevtsova, Valentina

    Fluids are present everywhere in everyday life. They are also present as fuel, in support systems or as consumable in rockets and onboard of satellites and space stations. Everyone experiences every day that fluids are very sensitive to gravity: on Earth liquids flow downwards and gases mostly rise. Nowadays much of the interest of the scientific community is on studying the phenomena at microscales in so-called microfluidic systems. However, at smaller scales the experimental investigation of convective flows becomes increasingly difficult as the control parameter Ra scales with g L (3) (g; acceleration level, L: length scale). A unique alternative to the difficulty of investigating systems with small length scale on the ground is to reduce the gravity level g. In systems with interfaces, buoyancy forces are proportional to the volume of the liquid, while capillary forces act solely on the liquid surface. The importance of buoyancy diminishes either at very small scales or with reducing the acceleration level. Under the weightless conditions of space where buoyancy is virtually eliminated, other mechanisms such as capillary forces, diffusion, vibration, shear forces, electrostatic and electromagnetic forces are dominating in the fluid behaviour. This is why research in space represents a powerful tool for scientific research in this field. Understanding how fluids work really matters and so does measuring their properties accurately. Presently, a number of scientific laboratories, as usual goes with multi-user instruments, are involved in fluid research on the ISS. The programme of fluid physics experiments on-board deals with capillary flows, diffusion, dynamics in complex fluids (foams, emulsions and granular matter), heat transfer processes with phase change, physics and physico-chemistry near or beyond the critical point and it also extends to combustion physics. The top-level objectives of fluid research in space are as follows: (i) to investigate fluid

  16. Phase diagram and transport properties for hydrogen-helium fluid planets

    International Nuclear Information System (INIS)

    Stevenson, D.J.; Salpeter, E.E.

    1977-01-01

    Hydrogen and helium are the major constituents of Jupiter and Saturn, and phase transitions can have important effects on the planetary structure. In this paper, the relevant phase diagrams and microscopic transport properties are analyzed in detail. The following paper (Paper II) applies these results to the evolution and present dynamic structure of the Jovian planets.Pure hydrogen is first discussed, especially the nature of the molecular-metallic transition and the melting curves for the two phases. It is concluded that at the temperatures and pressures of interest (Tapprox. =10 4 K, Papprox. =1--10 Mbar), both phases are fluid, but the transition between them might nevertheless be first-order. The insulator-metal transition in helium occurs at a much higher pressure (approx.70 Mbars) and is not of interest.The phase diagrams for both molecular and metallic hydrogen-helium mixtures are discussed. In the metallic mixture, calculations indicate a miscibility gap for T9 or approx. =10 4 K. Immiscibility in the molecular mixture is more difficult to predict but almost certainly occurs at much lower temperatures. A fluid-state model is constructed which predicts the likely topology of the three-dimensional phase diagram. The greater solubility of helium in the molecular phase leads to the prediction that the He/H mass ratio is typically twice as large in the molecular phase as in the coexisting metallic phase. Under these circumstances a ''density inversion'' is possible in which the molecular phase becomes more dense than the metallic phase.The partitioning of minor constituents is also considered: The deuterium/hydrogen mass ratio is essentially the same for all coexisting hydrogen-helium phases, at least for T> or approx. =5000 K. The partitioning of H 2 O, CH 4 , and NH 3 probably favors the molecular (or helium-rich) phase. Substances with high conduction electron density (e.g., Al) may partition into the metallic phase

  17. Introduction to meteorological measurements and data handling for solar energy applications. Task IV. Development of an isolation handbook and instrument package

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The following are covered: the Sun and its radiation, solar radiation and atmospheric interaction, solar radiation measurement methods, spectral irradiance measurements of natural sources, the measurement of infrared radiation, the measurement of circumsolar radiation, some empirical properties of solar radiation and related parameters, duration of sunshine, and meteorological variables related to solar energy. Included in appendices are manufacturers and distributors of solar radiation measuring instruments and an approximate method for quality control of solar radiation instruments. (MHR)

  18. Optical Performance of Breadboard Amon-Ra Imaging Channel Instrument for Deep Space Albedo Measurement

    Directory of Open Access Journals (Sweden)

    Won Hyun Park

    2007-03-01

    Full Text Available The AmonRa instrument, the primary payload of the international EARTHSHINE mission, is designed for measurement of deep space albedo from L1 halo orbit. We report the optical design, tolerance analysis and the optical performance of the breadborad AmonRa imaging channel instrument optimized for the mission science requirements. In particular, an advanced wavefront feedback process control technique was used for the instrumentation process including part fabrication, system alignment and integration. The measured performances for the complete breadboard system are the RMS 0.091 wave(test wavelength: 632.8 nm in wavefront error, the ensquared energy of 61.7%(in 14 μ m and the MTF of 35.3%(Nyquist frequency: 35.7 mm^{-1} at the center field. These resulting optical system performances prove that the breadboard AmonRa instrument, as built, satisfies the science requirements of the EARTHSHINE mission.

  19. The Karen instruments for measuring quality of nursing care: construct validity and internal consistency.

    Science.gov (United States)

    Lindgren, Margareta; Andersson, Inger S

    2011-06-01

    Valid and reliable instruments for measuring the quality of care are needed for evaluation and improvement of nursing care. Previously developed and evaluated instruments, the Karen-patient and the Karen-personnel based on Donabedian's Structure-Process-Outcome triad (S-P-O triad) had promising content validity, discriminative power and internal consistency. The objective of this study was to further develop the instruments with regard to construct validity and internal consistency. This prospective study was carried out in medical and surgical wards at a hospital in Sweden. A total of 95 patients and 120 personnel were included. The instruments were tested for construct validity by performing factor analyses in two steps and for internal consistency using Cronbach's alpha coefficient. The first confirmatory factor analyses, with a pre-determined three-factor solution did not load well according to the S-P-O triad, but the second exploratory factor analysis with a six-factor solution appeared to be more coherent and the distribution of variables seemed to be logical. The reliability, i.e. internal consistency, was good in both factor analyses. The Karen-patient and the Karen-personnel instruments have achieved acceptable levels of construct validity. The internal consistency of the instruments is good. This indicates that the instruments may be suitable to use in clinical practice for measuring the quality of nursing care.

  20. Property Uncertainty Analysis and Methods for Optimal Working Fluids of Thermodynamic Cycles

    DEFF Research Database (Denmark)

    Frutiger, Jerome

    in the context of an industrial organic Rankine cycle, used for the recovery of waste heat from an engine of a marine container ship. The study illustrates that the model structure is vital for the uncertainties of equations of state and suggests that uncertainty becomes a criterion (along with e.g. goodness......-of-fit or ease of use) for the selection of an equation of state for a specific application. Furthermore, two studies on the identification of suitable working fluids for thermodynamic cycles are presented. The first one selects and assesses working fluid candidates for an organic Rankine cycle system to recover......There is an increasing interest in recovering industrial waste heat at low tempera-tures (70-250◦C). Thermodynamic cycles, such as heat pumps or organic Rankine cycles, can recover this heat and transfer it to other process streams or convert it into electricity. The working fluid, circulating...

  1. Similarity rules of thermal stratification phenomena for water and sodium

    International Nuclear Information System (INIS)

    Ohtsuka, M.; Ikeda, T.; Yamakawa, M.; Shibata, Y.; Moriya, S.; Ushijima, S.; Fujimoto, K.

    1988-01-01

    Similarity rules for thermal stratification phenomena were studied using sodium and water experiments with scaled cylindrical vessels. The vessel dimensions were identical to focus on the effect of differences in fluid properties upon the phenomena. Comparisons of test results between sodium and water elucidated similar and dissimilar characteristics for thermal stratification phenomena which appeared in the scaled vessels. Results were as follows: (1) The dimensionless upward velocity of the thermal stratification interface was proportional to Ri -0.74 for water and sodium during the period when the buoyancy effect was dominant. (2) Dimensionless temperature transient rate at the outlet slit decreased with Ri for sodium and remained constant for water where Ri>0.2. The applicability of the scaled test results to an actual power plant was also studied by using multi-dimensional numerical analysis which was verified by the water and sodium experiments. Water experiments could simulate liquid metal fast breeder reactor flows more accurately than sodium experiments for dimensionless temperature gradient at the thermal stratification interface and dimensionless temperature transient rate at the intermediate heat exchanger inlet

  2. Measuring transient high temperature thermal phenomena in hostile environment

    International Nuclear Information System (INIS)

    Brenden, B.B.; Hartman, J.S.; Reich, F.R.

    1980-01-01

    The design of equipment for measuring temperature and strain in a rapidly heated and pressurized cylinder of stainless steel is discussed. Simultaneous cinematography of the full circumference of the cylinder without interference with temperature and strain measurements is also illustrated. The integrated system uses a reflective chamber for the sample and requires careful consideration of the spectral energy distribution utilized by each instrument

  3. Patient perspective: choosing or developing instruments.

    Science.gov (United States)

    Kirwan, John R; Fries, James F; Hewlett, Sarah; Osborne, Richard H

    2011-08-01

    Previous Outcome Measures in Rheumatology (OMERACT) meetings recognized that patients view outcomes of intervention from a different perspective. This preconference position paper briefly sets out 2 patient-reported outcome (PRO) instrument approaches, the PROMISE computer adaptive testing (CAT) system and development of a rheumatoid arthritis-specific questionnaire to measure fatigue; a tentative proposal for a PRO instrument development pathway is also made.

  4. Optimisation of the PGAA instrument at FRM II for low background and 2D measurements

    International Nuclear Information System (INIS)

    Canella, Lea

    2011-01-01

    At the beginning of 2008, the new Prompt Gamma-ray Activation Analysis (PGAA) facility started operation at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II). The main characteristic of this facility is the relatively intense cold neutron beam. This property is due to the special construction of the neutron beam guide; the last 7m are elliptically tapered, which means that the neutrons are focused on the sample. This arrangement allows for a max. neutron flux of 6.07 . 10 10 cm -2 s -1 , which is currently the highest cold neutron flux worldwide. Due to this high flux, the main problem encountered was the beam background, i.e. the radiation background created from irradiation of construction materials. The first part of this work was dedicated to the optimisation of the instrument. The goal achieved was a reduction of the background by a factor of 15. Once the instrument was optimised, measurements were dedicated to special elements like Cd, Sm, Eu, and Gd, that have very good characteristics for this method and to archaeological samples (old greek coins). Another improvement of the instrument was the development of a 2D imaging system. A new setup was installed in order to obtain spacial information about the distribution of elements inside samples. This imaging method was first applied to a small piece of the Allende meteorite with a different setup developed in the frame of the European Project ANCIENT CHARM. This setup was thought for 3D imaging, so the conditions were not optimal for 2D mapping. With this insight a second setup was built later specially dedicated for this application. In particular, the neutron field was reduced to a small spot of about 2 x 2 mm 2 and a two stage motor was built in order to allow the movement of the sample in two dimensions. Moreover, the possibility to evacuate the sample chamber was added. With this second setup the measurements on the Allende meteorite were repeated for a comparison. The 2D-setup was also applied

  5. An ultrasonic instrument for measuring density and viscosity of tank waste

    International Nuclear Information System (INIS)

    Sheen, S.H.; Chien, H.T.; Raptis, A.C.

    1997-01-01

    An estimated 381,000 m 3 /1.1 x 10 9 Ci of radioactive waste are stored in high-level waste tanks at the Hanford Savannah River, Idaho Nuclear Engineering and Environmental Laboratory, and West Valley facilities. This nuclear waste has created one of the most complex waste management and cleanup problems that face the United States. Release of radioactive materials into the environment from underground waste tanks requires immediate cleanup and waste retrieval. Hydraulic mobilization with mixer pumps will be used to retrieve waste slurries and salt cakes from storage tanks. To ensure that transport lines in the hydraulic system will not become plugged, the physical properties of the slurries must be monitored. Characterization of a slurry flow requires reliable measurement of slurry density, mass flow, viscosity, and volume percent of solids. Such measurements are preferably made with on-line nonintrusive sensors that can provide continuous real-time monitoring. With the support of the U.S. Department of Energy (DOE) Office of Environmental Management (EM-50), Argonne National Laboratory (ANL) is developing an ultrasonic instrument for in-line monitoring of physical properties of radioactive tank waste

  6. Rewetting phenomena and their relation to intermolecular forces between a hot wall and the fluid

    International Nuclear Information System (INIS)

    Gerweck, V.

    1989-12-01

    The rewetting phenomena and the different physical concepts which are used in their modelisation are reviewed. The present work studies the effect of the intermolecular forces between the hot wall and the fluid on this phase transition. Using suitable approximations, a local equation of state is obtained by the treatment of the fluid-fluid and fluid-wall intermolecular interactions. This local equation of state depends on the distance from the wall, and the critical pressure and temperature become a function of the distance from the wall, whereas the critical density is left constant throughout the fluid. At the wall, the critical pressure and temperature are half their bulk values and increase towards the bulk value as the distance from the wall increases. The penetration of a temperature profile in this fluid is studied by assuming that the liquid density is not strongly affected by this temperature profile as long as there is no phase transition. It is shown that the phase transition will occur extremely rapidly when the interfacial temperature upon contact is higher than the minimum of the local spinodal temperature, which varies with the distance from the wall. The result ist cast in the form of an interfacial rewetting temperature fT c above which rewetting of the surface by liquid-wall contacts is not expected because these contacts will be terminated in extremely short times. Comparing the theory with available data shows that in the usual rewetting situations the theory reduces to the use of the bulk spinodal temperature. For surfaces coated with poorly wetted materials the correction factor due to surface effects applies, reducing the rewetting temperature, in agreement with the experimental data. For liquid metals it appears that the theory is applied in a region where the basic theoretical approximations are very coarse; but even in that case the experimental trend is qualitatively predicted by the theory. (author) 43 figs., 11 tabs., 105 refs

  7. Proceedings of the Fifth Microgravity Fluid Physics and Transport Phenomena Conference

    Science.gov (United States)

    Singh, Bhim S. (Editor)

    2000-01-01

    The Fifth Microgravity Fluid Physics and Transport Phenomena Conference provided the scientific community the opportunity to view the current scope of the Microgravity Fluid Physics and Transport Phenomena Program and research opportunities and plans for the near future. Consistent with the conference theme "Microgravity Research an Agency-Wide Asset" the conference focused not only on fundamental research but also on applications of this knowledge towards enabling future space exploration missions. The conference included 14 invited plenary talks, 61 technical paper presentations, 61 poster presentations, exhibits and a forum on emerging research themes focusing on nanotechnology and biofluid mechanics. This web-based proceeding includes the presentation and poster charts provided by the presenters of technical papers and posters that were scanned at the conference site. Abstracts of all the papers and posters are included and linked to the presentations charts. The invited and plenary speakers were not required to provide their charts and are generally not available for scanning and hence not posted. The conference program is also included.

  8. Measurement Properties of Outcome Measures for Vitiligo A Systematic Review

    NARCIS (Netherlands)

    Vrijman, C.; Homan, M.W.L.; Limpens, J.; Veen, W.; Wolkerstorfer, A.; Terwee, C.B.; Spuls, P.I.

    2012-01-01

    Objective: To summarize and critically appraise the evidence on the measurement properties of clinician-, patient-, and observer-reported outcomes, measuring any construct of interest in patients with all types of vitiligo. Data Sources: Electronic databases including PubMed (1948 to July 2011),

  9. Measurement properties of outcome measures for vitiligo. A systematic review

    NARCIS (Netherlands)

    Vrijman, Charlotte; Linthorst Homan, May W.; Limpens, Jacqueline; van der Veen, Wietze; Wolkerstorfer, Albert; Terwee, Caroline B.; Spuls, Phyllis I.

    2012-01-01

    OBJECTIVE To summarize and critically appraise the evidence on the measurement properties of clinician-, patient-, and observer-reported outcomes, measuring any construct of interest in patients with all types of vitiligo. DATA SOURCES Electronic databases including PubMed (1948 to July 2011), OVID

  10. Removable butterfly valve, especially for polluting and/or dangerous fluids

    International Nuclear Information System (INIS)

    Garrigues, J.C.

    1984-01-01

    This invention relates to a valve for use in systems carrying polluting, corrosive or dangerous fluids requiring the use of biological protection. The facilities concerned are those in which fluids, mainly polluting, corrosive or dangerous liquids requiring the use of various types of biological protection, are handled. This is particularly so for nuclear installations in which the equipment is surrounded by protective shields which stop the radiation and prevent radioactive gases and aerosols from spreading. The invention proposes for the present valve a high-safety leaktightness system which respects the most specifications and standards and which suppresses any dead volume inside the valve [fr

  11. Instrumentation for two-phase flow measurements in code verification experiments

    International Nuclear Information System (INIS)

    Fincke, J.R.; Anderson, J.L.; Arave, A.E.; Deason, V.A.; Lassahn, G.D.; Goodrich, L.D.; Colson, J.B.; Fickas, E.T.

    1981-01-01

    The development of instrumentation and techniques for the measurement of mass flow rate in two-phase flows conducted at the Idaho National Engineering Laboratory during the past year is briefly described. Instruments discussed are the modular drag-disc turbine transducer, the gamma densitometers, the ultrasonic densitometer, Pitot tubes, and full-flow drag screens. Steady state air-water and transient steam-water data are presented

  12. Instrument for Solvent Extraction and Analysis (ISEE) of Organics from Regolith Simulant Using Supercritical Fluid Extraction and Chromatography

    Science.gov (United States)

    Franco, Carolina; Hintze, Paul E.

    2017-01-01

    ISEE is an instrument with the potential to perform extractions from regolith found on the surface of asteroids and planets, followed by characterization and quantitation of the extracts using supercritical fluid extraction (SFE) and chromatography (SFC). SFE is a developed technique proven to extract a wide range of organic compounds. SFC is similar to High Performance Liquid Chromatography (HPLC) but has the advantage of performing chiral separations without needing to derivatize the chiral compounds. CO2 will be the solvent for both stages as it is readily available in the Mars atmosphere. ISEE will capture CO2 from the environment, and use it for SFE and SFC. If successful, this would allow ISEE to perform analysis of organic compounds without using consumables. This paper will present results on a preliminary, proof-of-principle effort to use SFE and SFC to extract and analyze lunar regolith simulant spiked with organic compounds representing a range of organics that ISEE would expect to characterize. An optimization of variables for the extraction of the organics from the spiked regolith was successfully developed, using 138 bar pressure and 40 C temperature. The extraction flow rate was optimized at 2% SLPM with 30% methanol modifier. The extractions were successful with a value of 77.3+/- 0.9% of organics extracted. However, the recovery of organics after the extraction was very low with only 48.5+/-14.2%. Moreover, three columns were selected to analyze multiple samples at a time; two of them are Viridis HSS C18 SB and Torus DIOL, and the third column, specific for chiral separations, has not yet been selected yet.

  13. Electroseismic characterization of lithology and fluid type in the shallow subsurface. Final report, January 15, 1995--January 14, 1997

    Energy Technology Data Exchange (ETDEWEB)

    Haartsen, M.W.; Mikhailov, O.V.; Queen, J.H. [and others

    1997-07-01

    The U.S. Department of Energy funded the M.I.T. Earth Resources Laboratory to investigate electroseismic phenomena. Because electroseismic phenomena in fluid-saturated porous media provide geophysicists with a unique opportunity to detect a seismic-wave-generated flow of pore fluid with respect to the porous matrix. The term {open_quotes}electroseismic{close_quotes} describes phenomena in which a seismic wave induces an electrical field or causes radiation of an electromagnetic wave. Electroseismic phenomena take place in fluid-saturated porous rocks, because the pore fluid carries an excess electrical charge. When the charged pore fluid is forced to flow through the rock by pressure gradients within a seismic wave, a streaming electrical current is generated. This electrical current results in charge separation, which induces an electrical field. Measuring this seismic-wave-induced electrical field allows detection of the fluid flow generated by the wave in the porous medium. In turn, detecting the fluid flow allows characterization of fluid transport properties of the medium. The major contribution of our research is in the following three areas: (1) Theory. Theoretical models of various electroseismic phenomena in fluid-saturated porous media were developed. Numerical algorithms were developed for modeling electroseismic measurements in surface (Paper 1 in this report) and VSP (Paper 2) geometries. A closed-form analytical expression was obtained for the logging geometry (Paper 8). The major result is the theoretical models` prediction that porosity, permeability, and fluid chemistry can be characterized using electroseismic measurements; (2) Laboratory Experiments. A number of laboratory experiments were performed in surface (Paper 4), VSP (Paper 4), and logging (Paper 5) geometries. In addition, conversion of electrical energy into seismic energy was investigated (Paper 6), and (3) Field Measurements.

  14. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol.

    Science.gov (United States)

    Pérula, Luis Á; Campiñez, Manuel; Bosch, Josep M; Barragán Brun, Nieves; Arboniés, Juan C; Bóveda Fontán, Julia; Martín Alvarez, Remedios; Prados, Jose A; Martín-Rioboó, Enrique; Massons, Josep; Criado, Margarita; Fernández, José Á; Parras, Juan M; Ruiz-Moral, Roger; Novo, Jesús M

    2012-11-22

    Lifestyle is one of the main determinants of people's health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors' communication skills, and more specifically the Motivational Interviewing. The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire) is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. - Thirty-two primary care centers in Spain. -Sampling and Size: a) face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b) Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362). Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a) Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b) Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis), internal consistency (Cronbach alpha), intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology), generalizability, construct validity and sensitivity to change (Pearson product-moment correlation

  15. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol

    Directory of Open Access Journals (Sweden)

    Pérula Luis Á

    2012-11-01

    Full Text Available Abstract Background Lifestyle is one of the main determinants of people’s health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors’ communication skills, and more specifically the Motivational Interviewing. Methods/Design The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. –Scope: Thirty-two primary care centers in Spain. -Sampling and Size: a face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362. Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis, internal consistency (Cronbach alpha, intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology, generalizability, construct validity and

  16. Fabrication and Testing of Viscosity Measuring Instrument (Viscometer

    Directory of Open Access Journals (Sweden)

    A. B. HASSAN

    2006-01-01

    Full Text Available This paper presents the fabrication and testing of a simple and portable viscometer for the measurement of bulk viscosity of different Newtonian fluids. It is aimed at making available the instrument in local markets and consequently reducing or eliminating the prohibitive cost of importation. The method employed is the use of a D.C motor to rotate a disc having holes for infra-red light to pass through and fall on a photo-diode thus undergoing amplification and this signal being translated on a moving-coil meter as a deflection. The motor speed is kept constant but varies with changes in viscosity of the fluid during stirring, which alter signals being read on the meter. The faster is revolution per minute of the disc, the less the deflection on the meter and vise-versa. From the results of tests conducted on various sample fluids using data on standard Newtonian fluids as reliable guide the efficiency of the viscometer was 76.5%.

  17. A leak-detection instrument for long buried pipelines based on radioactive tracer measurements

    International Nuclear Information System (INIS)

    Lu Qingqian; Zhou Shuxuan; Tang Yonghua; Sun Xiaolei; Hu Xusheng; Li Deyi; Yin Liqiang

    1987-01-01

    The instrument introduced provides a means for leak detection of long buried pipelines based on the radioactive tracer technique. The principle, block diagram and performances for the instrument are described. The leak-detecting method and the determination of some related parameters are also presented. Leak-detection sensitivity of the instrument is 185 kBq (5 μCi). Accuracy for leak localization is within 2.5 m (per km). It is suitable for the buried light oil (gasoline, kerosene, diesel oil) and industrial water pipelines with a diameter of 15 or 20 cm. The detection length for a single operation reaches up to 50 km

  18. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer chemotherapy.

    Science.gov (United States)

    Lee, Clara N; Wetschler, Matthew H; Chang, Yuchiao; Belkora, Jeffrey K; Moy, Beverly; Partridge, Ann; Sepucha, Karen R

    2014-08-20

    Women diagnosed with early stage (I or II) breast cancer face a highly challenging decision - whether or not to undergo adjuvant chemotherapy. We developed a decision quality instrument for chemotherapy for early stage breast cancer and sought to evaluate its performance. Cross-sectional, mailed survey of recent breast cancer survivors, providers, and healthy controls and a retest survey of survivors. The decision quality instrument includes questions on knowledge and personal goals. It results in a knowledge score and concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, validity, and reliability of the survey instrument were examined. Responses were received from 352 patients, 89 providers and 35 healthy controls. The decision quality instrument was feasible to implement with few missing data. The knowledge scores had good retest reliability (intraclass correlation coefficient (ICC) =0.75). Knowledge scores discriminated between providers and patients (mean difference 31.1%, 95% CI 26.9, 35.3) and between patients and healthy controls (mean difference 11.2, 95% CI 5.4, 17.1). Most providers reported that the knowledge items covered essential content. Two of the five goal items had a ceiling effect, and one goal had low content validity. The goal items had moderate retest reliability (ICC's 0.57 to 0.78). In the multivariable model of treatment, none of the patient goals was associated with receipt of chemotherapy. Age and hormone receptor status were the only variables independently associated with chemotherapy. Most patients (77.6%) had treatment concordant with that predicted by the model. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. The Decision Quality Instrument is a reliable and valid measure of patient knowledge about chemotherapy, but its ability to measure concordance with patient goals is

  19. Direct laboratory observation of fluid distribution and its influence on acoustic properties of patchy saturated rocks

    Science.gov (United States)

    Lebedev, M.; Clennell, B.; Pervukhina, M.; Shulakova, V.; Mueller, T.; Gurevich, B.

    2009-04-01

    predictions of White's model. The results illustrate the non-unique relationships between saturation and velocity in sandstones dependent on texture and fluid displacement history: fuller understanding of these phenomena is needed for accurate assessment of time lapse seismic measurements, be they for oil and gas recovery or for CO2 disposal purposes. Gassmann, F., 1951, Elastic waves through a packing of spheres. Geophysics 16, 673-685; Mavko, G., T. Mukerji, and J. Dvorkin, 1998, The Rock Physics Handbook: Tools for seismic analysis in porous media: Cambridge University Press. Wood, A. W., 1955, A Textbook of Sound, The MacMillan Co., New York, 360 pp. Hill, R., 1963, Elastic properties of reinforced solids: some theoretical principles. J. Mech. Phys. Solids, 11, 357-372. Hill, R., 1952, The elastic behavior of crystalline aggregates. Proc. Physical Soc., London, A65, 349-354. J. Toms, T.M. Mueller, B. Gurevich, 2007 Seismic attenuation in porous rocks with random patchy saturation. Geophysical Prospecting, 55, 671-678.

  20. The quest for new phenomena

    International Nuclear Information System (INIS)

    Hinchliffe, I.

    1996-12-01

    The Standard Model of particle physics has been very successful in describing experimental data with great precision. With the exception of some neutrino anomalies, there is no data that is in disagreement with it. Nevertheless, the model is regarded as incomplete and unsatisfactory. There is no explanation of the pattern of quark and lepton masses and, possibly more important, no understanding of the scale of electroweak interactions. Electroweak symmetry breaking is implemented in the Standard Model from the presence of a scalar electroweak doublet, the Higgs field, that acquires a vacuum expectation value of order 250 GeV and leaves as a remnant one physical state, the electrically neutral Higgs boson whose mass is not predicted. In this talk, the author compares the techniques used at, and capabilities of, various facilities in searching for new phenomena. The author emphasizes the cases where information from more than one facility may be needed to fully explore the physics

  1. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    The US Department of Energy (DOE) has expressed a need for an on-line, real-time instrument for assaying alpha-emitting radionuclides (uranium and the transuranics) in effluent waters leaving DOE sites to ensure compliance with regulatory limits. Due to the short range of alpha particles in water (approximately40 Im), it is necessary now to intermittently collect samples of water and send them to a central laboratory for analysis. A lengthy and costly procedure is used to separate and measure the radionuclides from each sample. Large variations in radionuclide concentrations in the water may go undetected due to the sporadic sampling. Even when detected, the reading may not be representative of the actual stream concentration. To address these issues, the Advanced Technologies Group of Thermo Power Corporation (a Thermo Electron company) is developing a real-time, field-deployable alpha monitor based on a solid-state silicon wafer semiconductor (US Patent 5,652,013 and pending, assigned to the US Department of Energy). The Thermo Water Alpha Monitor will serve to monitor effluent water streams (Subsurface Contaminants Focus Area) and will be suitable for process control of remediation as well as decontamination and decommissioning (D and D) operations, such as monitoring scrubber or rinse water radioactivity levels (Mixed Waste, Plutonium, and D and D Focus Area). It would be applicable for assaying other liquids, such as oil, or solids after proper preconditioning. Rapid isotopic alpha air monitoring is also possible using this technology. This report details the program's accomplishments to date. Most significantly, the Alpha Monitoring Instrument was successfully field demonstrated on water 100X below the Environmental Protection Agency's proposed safe drinking water limit--down to under 1 pCi/1. During the Field Test, the Alpha Monitoring Instrument successfully analyzed isotopic uranium levels on a total of five different surface water, process water, and

  2. Psychometric Properties of a Screening Instrument for Domestic Violence in a Sample of Iranian Women

    Science.gov (United States)

    Azadarmaki, Taghi; Kassani, Aziz; Menati, Rostam; Hassanzadeh, Jafar; Menati, Walieh

    2016-01-01

    Background Domestic violence against women is regarded as an important health problem among women and a serious concern in issues related to human rights. To date, a few screening tools for domestic violence exist for Iranian married women, but they assess only some of the domestic violence components. Objectives The present study aimed to design and determine the validity and reliability of a screening instrument for domestic violence in a sample of Iranian women. Materials and Methods The present study was a cross-sectional psychometric evaluation conducted on 350 married women in Ilam, Iran, in 2014. The samples were selected through multistage sampling and the main method was cluster sampling. A 20-item, self-administered questionnaire was validated by exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). An Eigen value > 1 and a loading factor > 0.3 for each component were considered as indices for extracting domestic violence components. Reliability was calculated by test-retest and Cronbach’s alpha. Also, the content validity index (CVI) and content validity ratio (CVR) were used to measure content validity. The data were analyzed using SPSS-13 and LISREL 8.8 software programs. Results The self-administered instrument was completed by 334 women. The CFA and EFA methods confirmed embedding items and the three-factor structure of the instrument including psychological, physical, and sexual violence, which explained 66% of the total variance of the domestic violence. The ICC and Cronbach’s alpha coefficients were > 0.7 for the components of the questionnaire. The test-retest also revealed strong correlations for each of the domestic violence components (r > 0.6). Conclusions The used instrument for measuring domestic violence had desirable validity and reliability and can be used as a suitable instrument in health and social researches in the local population. PMID:27331052

  3. Feasibility study for CPR1000 incore measurement instrumentation educed from the reactor pressure vessel upper head

    International Nuclear Information System (INIS)

    Guang Jianwei; Liu Qian; Li Wenhong; Duan Yuangang

    2010-01-01

    The article discusses about the feasibility of in-core measurement instrumentation educed from the reactor pressure vessel (RPV) upper head. Incore instrumentation educed from the reactor pressure vessel upper head is one of advanced technology in the third generation nuclear power plant. This technology can reduce the manufacture problem of RPV; decrease the manufacture time effectively. Furthermore, this technology can get rid of the trouble for loss of water caused by many penetrations in the RPV bottom head, can increase security of nuclear power plant. By the description of structure analysis, comparison, maturity for four type incore instrumentation detectors, the incore instrumentation can be educed from RPV upper head, which can increase reactor's security, reduce the manufacture time, decrease group dose in refueling period. The core design ability can be enhanced through this study. (authors)

  4. Validating an instrument for measuring brand equity of CSR driven organizations in Malaysia

    Directory of Open Access Journals (Sweden)

    Singh Dara Singh Karpal

    2017-06-01

    Full Text Available The objective of this study is to develop and propose a valid and reliable instrument to measure brand equity of CSR driven organizations in Malaysia. An instrument to measure brand equity was constructed with adaptations from two key sources, namely Yew Leh and Lee (2011 and Yoo and Donthu (2001. As such the study only focuses on the development and validation of an instrument to measure brand equity of CSR driven organizations. The usable sample population included 909 respondents from 12 states of West Malaysia which were selected using a quota sampling plan. Confirmatory factor analysis (CFA and reliability analysis were carried out to test and validate the proposed brand equity instrument containing four components (brand awareness, brand association, perceived quality and brand loyalty with a total of 13 items. Results from the CFA and reliability analysis indicated that all the items representing the four components were valid and can be used to measure the brand equity of organizations that are practicing CSR. The study tried to set an empirical basis for brand equity and CSR related research which could be used by future researchers in different industries and geographical locations. The study also implies the need for organizations to assess the success of their CSR efforts through the use of the proposed instrument in order to gauge whether all their CSR efforts translate to improved brand equity.

  5. QNOTE: an instrument for measuring the quality of EHR clinical notes.

    Science.gov (United States)

    Burke, Harry B; Hoang, Albert; Becher, Dorothy; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; Sessums, Laura L; O'Malley, Patrick; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2014-01-01

    The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS

    International Nuclear Information System (INIS)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J.

    2007-01-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  7. Thermophysical Properties and Phase Behavior of Fluids for Application in Carbon Capture and Storage Processes.

    Science.gov (United States)

    Trusler, J P Martin

    2017-06-07

    Phase behavior and thermophysical properties of mixtures of carbon dioxide with various other substances are very important for the design and operation of carbon capture and storage (CCS) processes. The available empirical data are reviewed, together with some models for the calculation of these properties. The systems considered in detail are, first, mixtures of carbon dioxide, water, and salts; second, carbon dioxide-rich nonelectrolyte mixtures; and third, mixtures of carbon dioxide with water and amines. The empirical data and the plethora of available models permit the estimation of key fluid properties required in the design and operation of CCS processes. The engineering community would benefit from the further development, and delivery in convenient form, of a small number of these models sufficient to encompass the component slate and operating conditions of CCS processes.

  8. A Practitioner's Instrument for Measuring Secondary Mathematics Teachers' Beliefs Surrounding Learner-Centered Classroom Practice.

    Science.gov (United States)

    Lischka, Alyson E; Garner, Mary

    In this paper we present the development and validation of a Mathematics Teaching Pedagogical and Discourse Beliefs Instrument (MTPDBI), a 20 item partial-credit survey designed and analyzed using Rasch measurement theory. Items on the MTPDBI address beliefs about the nature of mathematics, teaching and learning mathematics, and classroom discourse practices. A Rasch partial credit model (Masters, 1982) was estimated from the pilot study data. Results show that item separation reliability is .96 and person separation reliability is .71. Other analyses indicate the instrument is a viable measure of secondary teachers' beliefs about reform-oriented mathematics teaching and learning. This instrument is proposed as a useful measure of teacher beliefs for those working with pre-service and in-service teacher development.

  9. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  10. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders

    NARCIS (Netherlands)

    Abma, F.I.; van der Klink, J.J.L.; Terwee, C.B.; Amick, B.C.; Bultmann, U.

    2012-01-01

    Objectives During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in

  11. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  12. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  13. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) has expressed a need for an on-line, real-time instrument for assaying alpha-emitting radionuclides (uranium and the transuranics) in effluent waters leaving DOE sites to ensure compliance with regulatory limits. Due to the short range of alpha particles in water (approximately40 Tm), it is necessary now to intermittently collect samples of water and send them to a central laboratory for analysis. A lengthy and costly procedure is used to separate and measure the radionuclides from each sample. Large variations in radionuclide concentrations in the water may go undetected due to the sporadic sampling. Even when detected, the reading may not be representative of the actual stream concentration. To address these issues, Tecogen, a division of Thermo Power Corporation, a Thermo Electron company, is developing a real-time, field-deployable, alpha monitor based on a solid-state silicon wafer semiconductor (patent pending, to be assigned to the Department of Energy). The Thermo Alpha Monitor (TAM) will serve to monitor effluent water streams (Subsurface Contaminants Focus Area) and will be suitable for process control of remediation as well as decontamination and decommissioning operations, such as monitoring scrubber or rinse water radioactivity levels (Mixed Waste Focus Area and D and D Focus Area). It would be applicable for assaying other liquids, such as oil, or solids after proper preconditioning. Rapid isotopic alpha air monitoring is also possible using this technology. This instrument for direct counting of alpha-emitters in aqueous streams is presently being developed by Thermo Power under a development program funded by the DOE Environmental Management program (DOE-EM), administered by the Morgantown Energy Technology Center (METC). Under this contract, Thermo Power has demonstrated a solid-state, silicon-based semiconductor instrument, which uses a proprietary film-based collection system to quantitatively extract the

  14. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    Directory of Open Access Journals (Sweden)

    Vahid Zamanzadeh

    2015-06-01

    Full Text Available ABSTRACT Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment. At the first step, domain determination, sampling (item generation and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items, informational support (seven items, emotional support (five items, problem solving (seven items, patient activation (10 items, intimacy/friendship (six items and spirituality strengthening (14 items. Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument.

  15. The Dedicated Aerosol Retrieval Experiment (DARE): scientific requirements for a dedicated satellite instrument to measure atmospheric aerosols

    NARCIS (Netherlands)

    Decae, R.; Courrèges-Lacoste, G.B.; Leeuw, G. de

    2004-01-01

    DARE (Dedicated Aerosol Retrieval Experiment) is a study to design an instrument for accurate remote sensing of aerosol properties from space. DARE combines useful properties of several existing instruments like TOMS, GOME, ATSR and POLDER. It has a large wavelength range, 330 to 1000 nm, to

  16. Interferometric 30 m bench for calibrations of 1D scales and optical distance measuring instruments

    International Nuclear Information System (INIS)

    Unkuri, J; Rantanen, A; Manninen, J; Esala, V-P; Lassila, A

    2012-01-01

    During construction of a new metrology building for MIKES, a 30 m interferometric bench was designed. The objective was to implement a straight, stable, adjustable and multifunctional 30 m measuring bench for calibrations. Special attention was paid to eliminating the effects of thermal expansion and inevitable concrete shrinkage. The linear guide, situated on top of a monolithic concrete beam, comprises two parallel round shafts with adjustable fixtures every 1 m. A carriage is moved along the rail and its position is followed by a reference interferometer. Depending on the measurement task, one or two retro-reflectors are fixed on the carriage. A microscope with a CCD camera and a monitor can be used to detect line mark positions on different line standards. When calibrating optical distance measuring instruments, various targets can be fixed to the carriage. For the most accurate measurements an online Abbe-error correction based on simultaneous carriage pitch measurement by a separate laser interferometer is applied. The bench is used for calibrations of machinist scales, tapes, circometers, electronic distance meters, total stations and laser trackers. The estimated expanded uncertainty for 30 m displacement for highest accuracy calibrations is 2.6 µm. (paper)

  17. Development of instrumentation in the transport phenomena research in thermal equipment

    International Nuclear Information System (INIS)

    Carvalho Tofani, P. de; Ladeira, L.C.D.

    1983-11-01

    The results obtained from the effort on the acquisition of know-how in experimental reactor thermal during the last years, through the approach of relevant aspects of basic research on transport phenomena applicable to nuclear reactor analysis and conventional thermal equipment based in the simultaneous development of instrumentation and experimental methods are presented. (E.G.) [pt

  18. THE DEVELOPMENT OF AN INSTRUMENT FOR MEASURING THE UNDERSTANDING OF PROFIT-MAXIMIZING PRINCIPLES.

    Science.gov (United States)

    MCCORMICK, FLOYD G.

    THE PURPOSE OF THE STUDY WAS TO DEVELOP AN INSTRUMENT FOR MEASURING PROFIT-MAXIMIZING PRINCIPLES IN FARM MANAGEMENT WITH IMPLICATIONS FOR VOCATIONAL AGRICULTURE. PRINCIPLES WERE IDENTIFIED FROM LITERATURE SELECTED BY AGRICULTURAL ECONOMISTS. FORTY-FIVE MULTIPLE-CHOICE QUESTIONS WERE REFINED ON THE BASIS OF RESULTS OF THREE PRETESTS AND…

  19. Exploring the psychometric properties of the humanistic teaching practices effectiveness questionnaire, an instrument to measure the humanistic qualities of medical teachers.

    Science.gov (United States)

    Logio, Lia Suzanne; Monahan, Patrick; Stump, Timothy E; Branch, William T; Frankel, Richard M; Inui, Thomas S

    2011-08-01

    To describe the development and psychometric properties of the Humanistic Teaching Practices Effectiveness Questionnaire (HTPE), an instrument that measures the humanistic skills of attending physicians within an academic health center (AHC) department of medicine. From August 2005 through March 2007, the authors distributed the HTPE, along with other standard faculty evaluations, to internal medicine and medicine/pediatrics residents at a single midwestern AHC (the Indiana University School of Medicine), in an effort to assess the instrument's validity and reliability. The data set included 886 completed HTPE questionnaires, representing 73% of the 1,212 administered. Exploratory factor analysis demonstrated a single major factor with high internal consistency reliability. The correlation between the HTPE and routine teaching evaluation tools was low. Interrater reliability was only fair (0.17). Total HTPE scores were not significantly different between female and male attending physicians. The 10-item HTPE provides reliable and valid information on the humanistic teaching practices of internal medicine faculty at a single AHC. The ability to reliably measure these practices provides a framework for understanding and promoting the skills to effectively demonstrate humanism at the bedside and in the clinic. The low correlation between the HTPE and other faculty evaluations suggests that the former measures a unique domain in attending physicians' performance. The HTPE items cluster together as a single construct allowing educators to choose fewer items without compromising reliability; however, moderate interrater reliability indicates that multiple raters are required to produce reliable scores.

  20. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    Science.gov (United States)

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control

  1. The quantitative measurement of organizational culture in health care: a review of the available instruments.

    Science.gov (United States)

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-06-01

    To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.

  2. Thermophysical properties of fluids: dynamic viscosity and thermal conductivity

    Science.gov (United States)

    Latini, G.

    2017-11-01

    Thermophysical properties of fluids strongly depend upon atomic and molecular structure, complex systems governed by physics laws providing the time evolution. Theoretically the knowledge of the initial position and velocity of each atom, of the interaction forces and of the boundary conditions, leads to the solution; actually this approach contains too many variables and it is generally impossible to obtain an acceptable solution. In many cases it is only possible to calculate or to measure some macroscopic properties of fluids (pressure, temperature, molar volume, heat capacities...). The ideal gas “law,” PV = nRT, was one of the first important correlations of properties and the deviations from this law for real gases were usefully proposed. Moreover the statistical mechanics leads for example to the “hard-sphere” model providing the link between the transport properties and the molecular size and speed of the molecules. Further approximations take into account the intermolecular interactions (the potential functions) which can be used to describe attractions and repulsions. In any case thermodynamics reduces experimental or theoretical efforts by relating one physical property to another: the Clausius-Clapeyron equation provides a classical example of this method and the PVT function must be known accurately. However, in spite of the useful developments in molecular theory and computers technology, often it is usual to search for physical properties when the existing theories are not reliable and experimental data are not available: the required value of the physical or thermophysical property must be estimated or predicted (very often estimation and prediction are improperly used as synonymous). In some cases empirical correlations are useful, if it is clearly defined the range of conditions on which they are based. This work is concerned with dynamic viscosity µ and thermal conductivity λ and is based on clear and important rules to be respected

  3. Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow Velocity

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO2-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1–5 were in the range of 1.35–9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7–12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds. PMID:22666046

  4. Long-period fiber grating sensors for the measurement of liquid level and fluid-flow velocity.

    Science.gov (United States)

    Wang, Jian-Neng; Luo, Ching-Ying

    2012-01-01

    This paper presents the development and assessment of two types of Long Period Fiber Grating (LPFG)-based sensors including a mobile liquid level sensor and a reflective sensor for the measurement of liquid level and fluid-flow velocity. Shewhart control charts were used to assess the liquid level sensing capacity and reliability of the mobile CO(2)-laser engraved LPFG sensor. There were ten groups of different liquid level experiment and each group underwent ten repeated wavelength shift measurements. The results showed that all measurands were within the control limits; thus, this mobile sensor was reliable and exhibited at least 100-cm liquid level measurement capacity. In addition, a reflective sensor consisting of five LPFGs in series with a reflective end has been developed to evaluate the liquid level and fluid-flow velocity. These five LPFGs were fabricated by the electrical arc discharge method and the reflective end was coated with silver by Tollen's test. After each liquid level experiment was performed five times, the average values of the resonance wavelength shifts for LPFG Nos. 1-5 were in the range of 1.35-9.14 nm. The experimental findings showed that the reflective sensor could be used to automatically monitor five fixed liquid levels. This reflective sensor also exhibited at least 100-cm liquid level measurement capacity. The mechanism of the fluid-flow velocity sensor was based on analyzing the relationship among the optical power, time, and the LPFG's length. There were two types of fluid-flow velocity measurements: inflow and drainage processes. The differences between the LPFG-based fluid-flow velocities and the measured average fluid-flow velocities were found in the range of 8.7-12.6%. For the first time to our knowledge, we have demonstrated the feasibility of liquid level and fluid-flow velocity sensing with a reflective LPFG-based sensor without modifying LPFGs or coating chemical compounds.

  5. Radioisotope instrument for measuring the position of interface of two liquid media with similar density

    International Nuclear Information System (INIS)

    Afanas'ev, V.N.; Kolyada, A.N.; Krejndlin, I.I.; Pakhunkov, Yu.I.

    1977-01-01

    A gamma level indicator is developed for automatic and continuous remote measuring the location of the interface of two liquids with close densities in closed and open containers. The density of the upper (light) medium is 1.0-1.2 g/cm 3 . The instrument incorporates a transmitter-receiver unit, a relay regulator, a power amplifier and a secondary instrument. The operating principle of the level indicator is based on the detection of gamma-radiation scattered by a controlled medium; the alternations in gamma radiation flux serve to automatically set the transmitter-receiver unit on the interface of two media. The specially developed small transmitter-receiver with an Am 241 gamma radiation source is very sensible to little medium density changes and stable against perturbing factor action. The level indicator developed may be used to measure and regulate the level of liquid contacting with an air (gas) medium. The specifications of the instrument are presented

  6. Instruments to measure behavioural and psychological symptoms of dementia.

    Science.gov (United States)

    van der Linde, Rianne M; Stephan, Blossom C M; Dening, Tom; Brayne, Carol

    2014-03-01

    Reliable and valid measurement of behavioural and psychological symptoms of dementia (BPSD) is important for research and clinical practice. Here we provide an overview of the different instruments and discuss issues involved in the choice of the most appropriate instrument to measure BPSD in research. A list of BPSD instruments was generated. For each instrument Pubmed and SCOPUS were searched for articles that reported on their use or quality. Eighty-three instruments that are used to measure BPSD were identified. Instruments differ in length and detail, whether the interview is with participants, informants or by observation, the target sample and the time frames for use. Reliability and validity is generally good, but reported in few independent samples. When choosing a BPSD instrument for research the research question should be carefully scrutinised and the symptoms of interest, population, quality, detail, time frame and practical issues should be considered. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Expansions of GMM statistics that indicate their properties under weak and/or many instruments and the bootstrap

    NARCIS (Netherlands)

    Kleibergen, F.R.

    2003-01-01

    We show that the sensitivity of the limit distribution of commonly used GMM statistics to weak and many instruments results from superfluous elements in the higher order expansion of these statistics. When the instruments are strong and their number is small, these elements are of higher order and

  8. Core outcome measurement instruments for clinical trials in non-specific low back pain

    DEFF Research Database (Denmark)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A

    2017-01-01

    Disability Index version 2.1a (ODI 2.1a) for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In Round 2...... COSMIN methodology. Researchers, clinicians and patients (n = 207) were invited in a two-round Delphi survey to generate consensus ( ≥ 67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In Round 1, consensus was achieved on the Oswestry......, consensus was reached on a NRS version with a 1-week recall period (96% agreement). Various participants requested one free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: ODI 2.1a or 24-item Roland-Morris Disability Questionnaire...

  9. Instrument for bone mineral measurement using a microprocessor as the control and arithmetic element

    International Nuclear Information System (INIS)

    Alberi, J.L.; Hardy, W.H. II.

    1975-11-01

    A self-contained instrument for the determination of bone mineral content by photon absorptometry is described. A high-resolution detection system allows measurements to be made at up to 16 photon energies. Control and arithmetic functions are performed by a microprocessor. Analysis capability and limitations are discussed

  10. Strategies for Successfully Teaching Students with ADD or ADHD in Instrumental Lessons

    Science.gov (United States)

    Melago, Kathleen A.

    2014-01-01

    Teachers can easily encounter students with Attention Deficit Disorder (ADD) or Attention Deficit Hyperactivity Disorder (ADHD) in the instrumental lesson setting. Applicable to instrumental lesson settings in the public or private schools, private studios, or college studios, this article focuses on specific strategies ranging from the…

  11. Numerical analysis of the thermal and fluid flow phenomena of the fluidity test

    Directory of Open Access Journals (Sweden)

    L. Sowa

    2010-01-01

    Full Text Available In the paper, two mathematical and numerical models of the metals alloy solidification in the cylindrical channel of fluidity test, which take into account the process of filling the mould cavity with molten metal, has been proposed. Velocity and pressure fields were obtained by solving the momentum equations and the continuity equation, while the thermal fields were obtained by solving the heat conduction equation containing the convection term. Next, the numerical analysis of the solidification process of metals alloy in the cylindrical mould channel has been made. In the models one takes into account interdependence of the thermal and dynamical phenomena. Coupling of the heat transfer and fluid flow phenomena has been taken into consideration by the changes of the fluidity function and thermophysical parameters of alloy with respect to the temperature. The influence of the velocity or the pressure and the temperature of metal pouring on the solid phase growth kinetics were estimated. The problem has been solved by the finite element method.

  12. Using analog instruments in Tracker video-based experiments to understand the phenomena of electricity and magnetism in physics education

    Science.gov (United States)

    Aguilar-Marín, Pablo; Chavez-Bacilio, Mario; Jáuregui-Rosas, Segundo

    2018-05-01

    Tracker is a piece of freeware software, designed to use video recorded images of the motion of objects as input data, and has been mostly applied in physics education to analyse and simulate physical phenomena in mechanics. In this work we report the application of Tracker to the study of experiments in electricity and magnetism using analog instruments for electrical signal measurements. As we are unable to directly video-track the motion of electrons in electric circuits, the angular deflections of the instruments’ pointers were video captured instead. The kinematic variables (angular position as a function of time) had to be related to the electrical ones (voltages and currents as a function of time). Two well-known experiments in physics teaching, the RC circuit for charging and discharging a capacitor and Faraday electromagnetic induction, were chosen to illustrate the procedures. The third experiment analysed and modeled with Tracker was the rather well-known electromagnetic retardation of disk- or cylinder-shaped magnets falling inside non-magnetic metallic pipes. Instead of metallic pipes we used an aluminum plate with an arrangement of a couple of parallelepiped-shaped magnets falling parallel to the plate. In the three cases studied, the experimental and the Tracker simulation results were in very good agreement. These outcomes show that it is possible to exploit the potential of Tracker software in areas other than mechanics, in areas where electrical signals are involved. The experiments are inexpensive and simple to perform, and are suitable for high school and introductory undergraduate courses in electricity, magnetism and electronics. We propose the use of Tracker combined with analog measuring devices to explore further its applications in electricity, magnetism, electronics and in other experimental sciences where electrical signals are involved.

  13. Psychosocial measures used to assess the effectiveness of school-based nutrition education programs: review and analysis of self-report instruments for children 8 to 12 years old.

    Science.gov (United States)

    Hernández-Garbanzo, Yenory; Brosh, Joanne; Serrano, Elena L; Cason, Katherine L; Bhattarai, Ranju

    2013-01-01

    To identify the psychometric properties of evaluation instruments that measure mediators of dietary behaviors in school-aged children. Systematic search of scientific databases limited to 1999-2010. Psychometric properties related to development and testing of self-report instruments for children 8-12 years old. Systematic search of 189 articles and review of 15 instruments (20 associated articles) meeting the inclusion criteria. Search terms used included children, school, nutrition, diet, nutrition education, and evaluation. Fourteen studies used a theoretical framework to guide the instrument's development. Knowledge and self-efficacy were the most commonly used psychosocial measures. Twelve instruments focused on specific nutrition-related behaviors. Eight instruments included over 40 items and used age-appropriate response formats. Acceptable reliability properties were most commonly reported for attitude and self-efficacy measures. Although most of the instruments were reviewed by experts (n = 8) and/or pilot-tested (n = 9), only 7 were tested using both rigorous types of validity and with low-income youth. Results from this review suggest that additional research is needed to develop more robust psychosocial measures for dietary behaviors, for low-income youth audiences. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  14. Instrument for ultrasonic measurement of physical quantities of flowing media, especially the flow velocity

    International Nuclear Information System (INIS)

    Thun, N.; Brown, A.E.

    1977-01-01

    The invention is based on the task to present an instrument for ultrasonic measurement of flow velocities with high accuracy which may be produced substantially cheaper because of the use of a simple circuit design and normal components. The task is solved according to the invention by connecting the output of the first signal level transmitter as main signal and the output of the second signal level transmitter as auxiliary signal with a summing circuit forming a control signal by adding and/or subtracting the auxiliary signal to/from the main signal and providing for a switch, controlled by the transmitting direction, causing alternatingly two different delay times for the reference signal to become effective. (orig./RW) [de

  15. Laminate for use in instrument dials or hands and method of making laminate

    International Nuclear Information System (INIS)

    Westland, J.M.; Crowther, A.

    1981-01-01

    A translucent sheet of PVC has a coating e.g. of black ink or luminous material, with apertures and optionally luminous or non-luminous indicia. Behind the apertures there are tritium-activated luminous indicia or markings which are covered by an opaque white sheet. A self-adhesive protective film may be temporarily applied to the coating. The laminated structure may be used for faces or hands in time-pieces or other instruments. The use of the white sheet and protective film prevents operatives coming into contact with luminous materials. (author)

  16. Measurement methods for several properties of scintillator

    International Nuclear Information System (INIS)

    Luo Fengqun; Ji Changsong

    1998-01-01

    The current paper describes the experimental measurement methods for the relative light output, the relative energy conversion efficiency, the intrinsic amplitude resolution and the detection efficiency of the scintillators and their temperature effects

  17. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service*†

    Science.gov (United States)

    Crossno, Jon E.; Berkins, Brenda; Gotcher, Nancy; Hill, Judith L.; McConoughey, Michelle; Walters, Mitchel

    2001-01-01

    Objectives: In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Methods: Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results: Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. Conclusions: ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas. PMID:11337948

  18. The Nurses Self-Concept Instrument (NSCI): assessment of psychometric properties for Australian domestic and international student nurses.

    Science.gov (United States)

    Angel, Elizabeth; Craven, Rhonda; Denson, Nida

    2012-07-01

    Professional self-concept is a critical driver of job satisfaction. In Australia, as international nursing enrolments rise, nursing is increasingly characterised by a professional body of international nurses who may differ from domestic Australian nurses in their nursing self-concept. At present, no psychometrically sound instrument for assessing nursing self-concept for Australian domestic and international nursing students is available. The purpose of this study was to: (1) develop an instrument (the Nurses' Self-Concept Instrument (NSCI)) to measure the professional self-concept of domestic and international nursing students in Australia, and (2) test the psychometric properties of this newly developed instrument. A literature review was conducted to generate the initial dimension and item pools to measure nurses' professional self-concept (NSCI). Two stakeholders examined the content and face validity of dimensions and items. Analysis was performed on data collected from 253 undergraduate nursing students in a large public university in Sydney, Australia, and consisted of domestic (n=218) and international (n=35) nursing students. Internal reliability was assessed using Cronbach's Alpha. Confirmatory factor analysis (CFA) was used to assess the construct validity of the NSCI. The resulting NSCI consisted of 14 items across four self-concept domains: care, leadership, staff relations, and knowledge. The CFA supported the hypothesised factor structure of the self-concept model. All reliabilities were acceptable for both domestic and international students (ranging from r=.78 to .93). The NSCI was shown to be a valid and reliable tool for assessing Australian domestic and international student nurses' professional self-concept. This instrument may also enable those responsible for recruitment of students into nursing courses to assess students' professional self-concept and implement appropriate strategies to foster the growth of lifelong career development

  19. Microcontroller based, ore grade measuring portable instruments for uranium mining industry

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Ore Face Scanning and Bore Hole Logging are important essential activities which are required to be carried out in any Uranium mining industry. Microcontroller based, portable instruments with built-in powerful embedded code for data acquisition (of Radiation counts) and Ore Grade calculations will become a handy measuring tool for miners. Nucleonix Systems has recently developed and made these two portable instruments available to UCIL, which are under use at Jaduguda and Narvapahar mines. Some of the important features of these systems are compact, light weight, portable, hand held, battery powered. Modes of Data Acquisition: CPS, CPM and ORE GRADE. Detector: Sensitive GM Tube. Choice of Adj. TC (Time Constant) in 'ORE GRADE', acquisition mode. Built-in automatic BG (Background) recording and subtraction provided to indicate net CPS, CPM or ore GRADE in PPM. Can store 1000 readings at users choice. Built-in RS232 serial port facilitates data downloading into PC. This paper focuses on design concepts and technical details for the above two products. (author)

  20. Microprocessor-controlled data-acquisition instrument for neutron-activation measurements

    International Nuclear Information System (INIS)

    Jones, B.A.

    1981-01-01

    This paper describes a microprocessor controlled data acquisition instrument designed at Lawrence Livermore National Laboratory to provide experimenters with a diagnostic tool for measuring the performance of laser imploded fusion targets via neutron activation techniques. This instrument features the ability to count four independent inputs simultaneously while providing a front panel readout of these inputs, plus a time of day clock. A hardcopy printout of the data is also provided by a built-in thermal printer. All running modes and parameters are user selectable via a front panel keypad, and a complete set of internal self-testing diagnostics are available for debug

  1. Discovery potential for new phenomena

    International Nuclear Information System (INIS)

    Godfrey, S.; Price, L.E.

    1997-03-01

    The authors examine the ability of future facilities to discover and interpret non-supersymmetric new phenomena. The authors first explore explicit manifestations of new physics, including extended gauge sectors, leptoquarks, exotic fermions, and technicolor models. They then take a more general approach where new physics only reveals itself through the existence of effective interactions at lower energy scales

  2. Development of performance assessment instrument based contextual learning for measuring students laboratory skills

    Science.gov (United States)

    Susilaningsih, E.; Khotimah, K.; Nurhayati, S.

    2018-04-01

    The assessment of laboratory skill in general hasn’t specific guideline in assessment, while the individual assessment of students during a performance and skill in performing laboratory is still not been observed and measured properly. Alternative assessment that can be used to measure student laboratory skill is use performance assessment. The purpose of this study was to determine whether the performance assessment instrument that the result of research can be used to assess basic skills student laboratory. This research was conducted by the Research and Development. The result of the data analysis performance assessment instruments developed feasible to implement and validation result 62.5 with very good categories for observation sheets laboratory skills and all of the components with the very good category. The procedure is the preliminary stages of research and development stages. Preliminary stages are divided in two, namely the field studies and literature studies. The development stages are divided into several parts, namely 1) development of the type instrument, 2) validation by an expert, 3) a limited scale trial, 4) large-scale trials and 5) implementation of the product. The instrument included in the category of effective because 26 from 29 students have very high laboratory skill and high laboratory skill. The research of performance assessment instrument is standard and can be used to assess basic skill student laboratory.

  3. A flow meter for ultrasonically measuring the flow velocity of fluids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention regards a flow meter for ultrasonically measuring the flow velocity of fluids comprising a duct having a flow channel with an internal cross section comprising variation configured to generate at least one acoustic resonance within the flow channel for a specific ultrasonic frequency......, and at least two transducers for generating and sensing ultrasonic pulses, configured to transmit ultrasonic pulses at least at said specific ultrasonic frequency into the flow channel such that the ultrasonic pulses propagate through a fluid flowing in the flow channel, wherein the flow meter is configured...

  4. Development and evaluation of a meter for measuring return line fluid flow rates during drilling

    Energy Technology Data Exchange (ETDEWEB)

    Loeppke, G.E.; Schafer, D.M.; Glowka, D.A.; Scott, D.D.; Wernig, M.D. (Sandia National Labs., Albuquerque, NM (United States)); Wright, E.K. (Ktech Corp., Albuquerque, NM (United States))

    1992-06-01

    The most costly problem routinely encountered in geothermal drilling is lost circulation, which occurs when drilling fluid is lost to the formation rather than circulating back to the surface. The successful and economical treatment of lost circulation requires the accurate measurement of drilling fluid flow rate both into and out of the well. This report documents the development of a meter for measuring drilling fluid outflow rates in the return line of a drilling rig. The meter employs a rolling counterbalanced float that rides on the surface of the fluid in the return line. The angle of the float pivot arm is sensed with a pendulum potentiometer, and the height of the float is calculated from this measurement. The float height is closely related to the fluid height and, therefore, the flow rate in the line. The prototype rolling float meter was extensively tested under laboratory conditions in the Wellbore Hydraulics Flow Facility; results from these tests were used in the design of the field prototype rolling float meter. The field prototype meter was tested under actual drilling conditions in August and September 1991 at the Long Valley Exploratory Well near Mammoth Lakes, Ca. In addition, the performance of several other commercially available inflow and outflow meters was evaluated in the field. The tested inflow meters included conventional pump stroke counters, rotary pump speed counters, magnetic flowmeters, and an ultrasonic Doppler flowmeter. On the return flow line, a standard paddlemeter, an acoustic level meter, and the prototype rolling float meter were evaluated for measuring drilling fluid outflow rates.

  5. Systems analysis of instrumentation for in situ examination of rock properties. Final report

    International Nuclear Information System (INIS)

    1976-10-01

    If salt beds or shale beds are used for burial of nuclear wastes, then boreholes that penetrate the beds will be sealed to prevent transport of water into the beds via the boreholes. There will be interest in monitoring the environment in local regions of the borehole for years to come. Such monitoring may be aimed at providing assurance that the integrity of the borehole plug and the integrity of borehole wall seals have not degraded. Of course, there will be interest in monitoring the burial vault geology as well, and the results of this study are relevant to this requirement also. A study of buried instrumentation in boreholes without any wires between the buried instruments and the surface of the earth was performed. Consequently, buried power supplies and through-the-earth communications systems are required. Study ground rules included the following: burial depths to range between 150 m and 1500 m; maximum temperature of 100 0 C at the burial depth; and system target lifetime of 10 to 100 years. The instrumentation system is separable into four functional subsystems: (A) a basic instrument subsystem; (B) a command, control, and data processing (CCD) subsystem; (C) a communication subsystem; and (D) a power supply subsystem. The major findings of the study are listed by subsystem

  6. On use of ZPR research reactors and associated instrumentation and measurement methods for reactor physics studies

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, J.P. [CEA,DEN, DER, SPEX, Experimental Physics Service, Cadarache, F-13108 St-Paul-Lez-Durance (France); Blaise, P. [CEA, DEN, DER, SPEX Experimental Programs Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France); Lyoussi, A. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France)

    2015-07-01

    The French atomic and alternative energies -CEA- is strongly involved in research and development programs concerning the use of nuclear energy as a clean and reliable source of energy and consequently is working on the present and future generation of reactors on various topics such as ageing plant management, optimization of the plutonium stockpile, waste management and innovative systems exploration. Core physics studies are an essential part of this comprehensive R and D effort. In particular, the Zero Power Reactor (ZPR) of CEA: EOLE, MINERVE and MASURCA play an important role in the validation of neutron (as well photon) physics calculation tools (codes and nuclear data). The experimental programs defined in the CEA's ZPR facilities aim at improving the calculation routes by reducing the uncertainties of the experimental databases. They also provide accurate data on innovative systems in terms of new materials (moderating and decoupling materials) and new concepts (ADS, ABWR, new MTR (e.g. JHR), GENIV) involving new fuels, absorbers and coolant materials. Conducting such interesting experimental R and D programs is based on determining and measuring main parameters of phenomena of interest to qualify calculation tools and nuclear data 'libraries'. Determining these parameters relies on the use of numerous and different experimental techniques using specific and appropriate instrumentation and detection tools. Main ZPR experimental programs at CEA, their objectives and challenges will be presented and discussed. Future development and perspectives regarding ZPR reactors and associated programs will be also presented. (authors)

  7. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  8. Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

    Science.gov (United States)

    Yeh, Nai-Chang

    1997-01-01

    The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

  9. Instrumenting a pressure suppression experiment for a Mark I boiling water reactor: another measurements engineering challenge

    International Nuclear Information System (INIS)

    Shay, W.M.; Brough, W.G.; Miller, T.B.

    1978-01-01

    A 1 / 5 -scale test facility of a pressure-suppression system from a Mark I boiling water reactor was instrumented with seven types of transducers to obtain high-accuracy, dynamic loading data during a hypothetical loss-of-coolant accident. A total of 27 air tests have been completed with an average of 175 transducers recorded for each test. An end-to-end calibration of the total measurement system was run to establish accuracy of the data. The instrumentation verified the analysis of the dynamic loading of the pressure-suppression system

  10. The manometric sorptomat—an innovative volumetric instrument for sorption measurements performed under isobaric conditions

    International Nuclear Information System (INIS)

    Kudasik, Mateusz

    2016-01-01

    The present paper discusses the concept of measuring the process of sorption by means of the volumetric method, developed in such a way as to allow measurements performed under isobaric conditions. On the basis of the concept in question, a prototype of a sorption instrument was built: the manometric sorptomat. The paper provides a detailed description of the idea of the instrument, and of the way it works. In order to evaluate the usefulness of the device in sorption measurements carried out under laboratory conditions, comparative studies were conducted, during which the results of sorption measurements obtained with the developed instrument were compared with the results Mateusz obtained with a reference device. The objects of comparison were the sorption capacities of hard coal samples, calculated on the basis of the established courses of the methane sorption process. The results were regarded as compatible if the compared values fell within the range of the measurement uncertainty of the two devices. For the sake of the comparative studies, fifteen granular samples of hard coal—representing the 0.20–0.25 mm grain fraction and coming from various mines of the Upper Silesian Coal Basin—were used. After comparing the results obtained with the original manometric sorptomat with the results obtained with the gravimetric reference device, it was observed that the compatibility of measurements of sorption capacities was over 90%, based on the defined criterion of the measurement compatibility. (paper)

  11. Geophysical and transport properties of reservoir rocks. Final report for task 4: Measurements and analysis of seismic properties

    Energy Technology Data Exchange (ETDEWEB)

    Cook, N.G.W.

    1993-05-01

    The principal objective of research on the seismic properties of reservoir rocks is to develop a basic understanding of the effects of rock microstructure and its contained pore fluids on seismic velocities and attenuation. Ultimately, this knowledge would be used to extract reservoir properties information such as the porosity, permeability, clay content, fluid saturation, and fluid type from borehole, cross-borehole, and surface seismic measurements to improve the planning and control of oil and gas recovery. This thesis presents laboratory ultrasonic measurements for three granular materials and attempts to relate the microstructural properties and the properties of the pore fluids to P- and S-wave velocities and attenuation. These experimental results show that artificial porous materials with sintered grains and a sandstone with partially cemented grains exhibit complexities in P- and S-wave attenuation that cannot be adequately explained by existing micromechanical theories. It is likely that some of the complexity observed in the seismic attenuation is controlled by details of the rock microstructure, such as the grain contact area and grain shape, and by the arrangement of the grain packing. To examine these effects, a numerical method was developed for analyzing wave propagation in a grain packing. The method is based on a dynamic boundary integral equation and incorporates generalized stiffness boundary conditions between individual grains to account for viscous losses and grain contact scattering.

  12. Method for measuring particulate and gaseous metals in a fluid stream, device for measuring particulate and gaseous metals in a fluid stream

    Science.gov (United States)

    Farber, Paul S.; Huang, Hann-Shen

    2001-01-01

    A method for analyzing metal in a fluid is provided comprising maintaining a first portion of a continuous filter media substrate at a temperature coinciding with the phase in which the metal is to be analyzed; contacting the fluid to a first portion of said substrate to retain the metal on the first portion of said substrate; preventing further contact of the fluid to the first portion of substrate; and contacting the fluid to a second portion of said substrate to retain metal on the second portion of the said substrate while simultaneously analyzing the first portion for metal. Also provided is a device for the simultaneous monitoring and analysis of metal in a fluid comprising a continuous filter media substrate; means for maintaining a first portion of said filter media substrate at a temperature coinciding with the phase in which the metal is to be analyzed; a means for contacting the fluid to the first portion of said substrate; a means for preventing further contact of the fluid to the first portion of substrate; a means for contacting the fluid to a second portion of said substrate to retain metal on the second portion of the said substrate; and means for analyzing the first portion for metal.

  13. Is playing string or wind musical instruments a risk factor for temporomandibular dysfunction? A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Alessandro Leite Cavalcanti

    2017-11-01

    Full Text Available Aim. Medical problems specifically affecting professional musicians are commonly mentioned in the literature. The present study is aimed to evaluate, through a systematic review, the possible association between the practice of string with bow and wind musical instruments and the occurrence of Temporomandibular Dysfunction (TMD. Methods. The search for articles was conducted in PubMed/Medline, Web of Science, Scopus, Lilacs, Cochrane Library, and Open Gray databases, and there was no restriction on language or date of publication. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA guidelines were followed. The MeSH terms used were: “music”; “temporomandibular joint”; “temporomandibular joint disorders”; “temporomandibular joint dysfunction syndrome”; and “occupational diseases”. Cross-sectional studies, case-control, cohort and clinical trials were included that involved the practice of string with bow and wind musical instruments and the occurrence of Temporomandibular Dysfunction (TMD. Articles were previously selected by title and abstract. Qualitative evaluation was done through the Newcastle-Ottawa Scale. Results. The literature search identified 732 studies, of which 10 met the inclusion criteria, nine of them cross-sectional studies and one a clinical intervention study. The TMD prevalence ranged from 47.0% to 89.0%. Recruitment of participants took place in professional schools and orchestras, and in bands of professional musicians. All studies reported associations between TMD and the practice of musical instruments, and violinists presented higher prevalence rates when compared to other instrument groups. Conclusion. All studies pointed to a possible association between TMD and the practice of string and wind musical instruments. More longitudinal and clinical trials studies are needed to verify any possible interrelationship.

  14. The psychometric properties of a shortened corporate entrepreneurship assessment instrument

    Directory of Open Access Journals (Sweden)

    Renier Steyn

    2017-08-01

    Aim: The aim of this research was to evaluate the psychometric properties of a measure of entrepreneurial climate. Entrepreneurial climate was measured using a shortened version of the Hornsby, Kuratko and Zahra (2002 instrument, called the Corporate Entrepreneurship Assessment Instrument (CEAI. Making information on the psychometric properties of the instrument available directly relates to its utility. Setting: The setting was medium to large South African companies. A random sample of employees was drawn from 53 selected companies across South Africa, with 60 respondents per company (N = 3 180. Methods: A cross-sectional survey design was used. Several instruments were administered, including the shortened version of the CEAI. Cronbach’s alpha was used to test for reliability and several methods were used to test for validity. Correlation analysis was used to test for concurrent validity, convergent validity and divergent validity. Principle component factor analysis was used to test for factorial validity and a t-test to test for known-group validity. Results: The results showed that the reliability for the total score of the shortened version of the CEAI was acceptable at 0.758. The results also showed some evidence of concurrent validity, as well as homogeneity among the items. With regard to factorial validity, all items loaded in accordance with the subscales of the instrument. The measure was able to distinguish, as expected, between government organisations and private business entities, suggesting known-group validity. Convergent validity and divergent validity were also assessed. Interesting to note was that entrepreneurship climate correlates more with general employee attitude (e.g. employee engagement; R= 0.420, p < 0.001 and organisational commitment, R = 0.331, p < 0.001 than with self-reported innovation (R = 0.277, p < 0.001 and R = 0.267, p < 0.001. Contribution: This paper not only provided information on the reliability

  15. A Structured Review of Generic and Specific Instruments for Measuring the Subjectively Assessed Quality of Life of Seniors

    Directory of Open Access Journals (Sweden)

    Monika Kacmarova

    2015-12-01

    Full Text Available The objective of the study is to offer a review of the instruments designed for measuring the subjectively assessed quality of life of seniors. At present it is possible to notice an increase of interest in the issue of the quality of life of specific groups of population; in addition, there is a large number of tools for its measuring. The aim of the present study is to provide a systematic review of generic and specific instruments for measuring quality of life of seniors which have been published in peer-reviewed journals and whose psychometric parameters have been verified. The search procedure formed a part of a larger retrieval search in which we analyzed 4829 abstracts in EBSCO and ProQuest Central full-text databases. We found 831 instruments which claimed to be measuring quality of life and were verified their reliability or validity. We identified 3 groups of instruments suitable for use in the senior age-group: generic methodologies applicable to adults in general, 7 generic tools and 9 specific tools designed exclusively for the senior age. The paper presents the measures designed for seniors who were analyzed and compared with regard to their psychometric parameters, purpose and theoretical framework utilized for their construction. In conclusion the authors of the study provide recommendations for the use of the selected methodologies for measuring the subjectively assessed quality of life of seniors.

  16. Special Properties of Coherence Scanning Interferometers for large Measurement Volumes

    International Nuclear Information System (INIS)

    Bauer, W

    2011-01-01

    In contrast to many other optical methods the uncertainty of Coherence Scanning Interferometer (CSI) in vertical direction is independent from the field of view. Therefore CSIs are ideal instruments for measuring 3D-profiles of larger areas (36x28mm 2 , e.g.) with high precision. This is of advantage for the determination of form parameters like flatness, parallelism and steps heights within a short time. In addition, using a telecentric beam path allows measurements of deep lying surfaces (<70mm) and the determination of form parameters with large step-heights. The lateral and spatial resolution, however, are reduced. In this presentation different metrological characteristics together with their potential errors are analyzed for large-scale measuring CSIs. Therefore these instruments are ideal tools in quality control for good/bad selections, e.g. The consequences for the practical use in industry and for standardization are discussed by examples of workpieces of automotive suppliers or from the steel industry.

  17. Portable dynamic light scattering instrument and method for the measurement of blood platelet suspensions

    International Nuclear Information System (INIS)

    Maurer-Spurej, Elisabeth; Brown, Keddie; Labrie, Audrey; Marziali, Andre; Glatter, Otto

    2006-01-01

    No routine test exists to determine the quality of blood platelet transfusions although every year millions of patients require platelet transfusions to survive cancer chemotherapy, surgery or trauma. A new, portable dynamic light scattering instrument is described that is suitable for the measurement of turbid solutions of large particles under temperature-controlled conditions. The challenges of small sample size, short light path through the sample and accurate temperature control have been solved with a specially designed temperature-controlled sample holder for small diameter, disposable capillaries. Efficient heating and cooling is achieved with Peltier elements in direct contact with the sample capillary. Focusing optical fibres are used for light delivery and collection of scattered light. The practical use of this new technique was shown by the reproducible measurement of latex microspheres and the temperature-induced morphological changes of human blood platelets. The measured parameters for platelet transfusions are platelet size, number of platelet-derived microparticles and the response of platelets to temperature changes. This three-dimensional analysis provides a high degree of confidence for the determination of platelet quality. The experimental data are compared to a matrix and facilitate automated, unbiased quality testing

  18. Introduction to instrumentation and measurements

    CERN Document Server

    Northrop, Robert B

    2014-01-01

    Weighing in on the growth of innovative technologies, the adoption of new standards, and the lack of educational development as it relates to current and emerging applications, the third edition of Introduction to Instrumentation and Measurements uses the authors' 40 years of teaching experience to expound on the theory, science, and art of modern instrumentation and measurements (I&M). What's New in This Edition: This edition includes material on modern integrated circuit (IC) and photonic sensors, micro-electro-mechanical (MEM) and nano-electro-mechanical (NEM) sensors, chemical and radiation sensors, signal conditioning, noise, data interfaces, and basic digital signal processing (DSP), and upgrades every chapter with the latest advancements. It contains new material on the designs of micro-electro-mechanical (MEMS) sensors, adds two new chapters on wireless instrumentation and microsensors, and incorporates extensive biomedical examples and problems. Containing 13 chapters, this third edition: Describ...

  19. An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle.

    Science.gov (United States)

    Bielmann, V; Gillan, J; Perkins, N R; Skidmore, A L; Godden, S; Leslie, K E

    2010-08-01

    Acquisition of high quality colostrum is an important factor influencing neonatal calf health. Many methods have been used to assess the Ig concentration of colostrum; however, improved, validated evaluation tools are needed. The aims of this study were to evaluate both optical and digital Brix refractometer instruments for the measurement of Ig concentration of colostrum as compared with the gold standard radial immunodiffusion assay laboratory assessment and to determine the correlation between Ig measurements taken from fresh and frozen colostrum samples for both Brix refractometer instruments. This research was completed using 288 colostrum samples from 3 different farms. It was concluded that the optical and digital Brix refractometers were highly correlated for both fresh and frozen samples (r=0.98 and r=0.97, respectively). Correlation between both refractometer instruments for fresh and frozen samples and the gold standard radial immunodiffusion assay were determined to be very similar, with a correlation coefficient between 0.71 and 0.74. Both instruments exhibited excellent test characteristics, indicating an appropriate cut-off point of 22% Brix score for the identification of good quality colostrum. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Visualization and measurement by image processing of thermal hydraulic phenomena by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, Nobuyuki

    1996-01-01

    Neutron Radiography was applied to visualization of thermal hydraulic phenomena and measurement was carried out by image processing the visualized images. Since attenuation of thermal neutron rays is high in ordinary liquids like water and organic fluid while it is low in most of metals, liquid flow behaviors can be visualized through a metallic wall by neutron radiography. Measurement of void fraction and flow vector field which is important to study thermal hydraulic phenomena can be carried out by image processing the images obtained by the visualization. Various two-phase and liquid metal flows were visualized by a JRR-3M thermal neutron radiography system in the present study. Multi-dimensional void fraction distributions in two-phase flows and flow vector fields in liquid metals, which are difficult to measure by the other methods, were successfully measured by image processing. It was shown that neutron radiography was efficiently applicable to study thermal hydraulic phenomena. (author)

  1. Instruments to measure anxiety in children, adolescents, and young adults with cancer: a systematic review.

    Science.gov (United States)

    Lazor, Tanya; Tigelaar, Leonie; Pole, Jason D; De Souza, Claire; Tomlinson, Deborah; Sung, Lillian

    2017-09-01

    The primary objective was to describe anxiety measurement instruments used in children and adolescents with cancer or undergoing hematopoietic stem cell transplantation (HSCT) and summarize their content and psychometric properties. We conducted searches of MEDLINE, Embase, PsycINFO, HAPI, and CINAHL. We included studies that used at least one instrument to measure anxiety quantitatively in children or adolescents with cancer or undergoing HSCT. Two authors independently identified studies and abstracted study demographics and instrument characteristics. Twenty-seven instruments, 14 multi-item and 13 single-item, were used between 78 studies. The most commonly used instrument was the State-Trait Anxiety Inventory in 46 studies. Three multi-item instruments (Children's Manifest Anxiety Scale-Mandarin version, PROMIS Pediatric Anxiety Short Form, and the State-Trait Anxiety Inventory) and two single-item instruments (Faces Pain Scale-Revised and 10-cm Visual Analogue Scale, both adapted for anxiety) were found to be reliable and valid in children with cancer. We identified 14 different multi-item and 13 different single-item anxiety measurement instruments that have been used in pediatric cancer or HSCT. Only three multi-item and two single-item instruments were identified as being reliable and valid among pediatric cancer or HSCT patients and would therefore be appropriate to measure anxiety in this population.

  2. Microgravity Fluids for Biology, Workshop

    Science.gov (United States)

    Griffin, DeVon; Kohl, Fred; Massa, Gioia D.; Motil, Brian; Parsons-Wingerter, Patricia; Quincy, Charles; Sato, Kevin; Singh, Bhim; Smith, Jeffrey D.; Wheeler, Raymond M.

    2013-01-01

    Microgravity Fluids for Biology represents an intersection of biology and fluid physics that present exciting research challenges to the Space Life and Physical Sciences Division. Solving and managing the transport processes and fluid mechanics in physiological and biological systems and processes are essential for future space exploration and colonization of space by humans. Adequate understanding of the underlying fluid physics and transport mechanisms will provide new, necessary insights and technologies for analyzing and designing biological systems critical to NASAs mission. To enable this mission, the fluid physics discipline needs to work to enhance the understanding of the influence of gravity on the scales and types of fluids (i.e., non-Newtonian) important to biology and life sciences. In turn, biomimetic, bio-inspired and synthetic biology applications based on physiology and biology can enrich the fluid mechanics and transport phenomena capabilities of the microgravity fluid physics community.

  3. Evaluation of Two Passes Cold Pilgering Property for PLUS7TM Guide Thimble and Instrumentation Tubing

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Young; Park, Ki Bum; Kim, In Kyu; Lee, Young Hee; Kahng, Jong Yeol [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of)

    2015-05-15

    The thermo-mechanical property of zirconium alloy tube is well known to be influenced by pilgering pass schedule and its tooling; thus the control of its microstructure and mechanical property in the final tube production stage for nuclear fuel applications is a major concern of tube manufacture. To fabricate final tube, the 3 passes pilgering is applied in general by using TREX(Tube Reduced EXtrusion), 63.5mm outer diameter(OD), in KEPCO NF and most of Zr tube manufacturing companies. They are also taking big efforts to reduce pilgering step for the sake of increasing the efficiency of production in the forming stage of tube. The objective of this study is to develop two passes of pilgering schedule from the conventional three passes of pilgering schedule for manufacturing the Guide Thimble and Instrumentation tube conforming to specification, which are newly developing component for the advanced nuclear fuel assembly in KEPCO NF. CSR, hydride orientation, and structural integrity are well conformed to the desired targets so it is expected that both die and mandrel were newly designed for the PLUS7TM guide thimble and instrumentation tube with higher Q factor for two passes of pilgering at 50LC and 25LC pilger machine, instead of three passes of pilgering, are able to be applicable to this design of fuel component. If developed two passes pilgering is applied to current manufacturing process, it would improve not only productivity but also yield rate by reducing 3 steps(pilgering, heat-treatment, pickiling and cleaning) of manufacturing process. But additional tests(including in-pile test) should be performed in order to evaluate integrity in reactor.

  4. Final Report: Wireless Instrument for Automated Measurement of Clean Cookstove Usage and Black Carbon Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Lukac, Martin [Cirrus Sense LLC, Los Angeles, CA (United States); Ramanathan, Nithya [Cirrus Sense LLC, Los Angeles, CA (United States); Graham, Eric [Cirrus Sense LLC, Los Angeles, CA (United States)

    2013-09-10

    Black carbon (BC) emissions from traditional cooking fires and other sources are significant anthropogenic drivers of radiative forcing. Clean cookstoves present a more energy-efficient and cleaner-burning vehicle for cooking than traditional wood-burning stoves, yet many existing cookstoves reduce emissions by only modest amounts. Further research into cookstove use, fuel types, and verification of emissions is needed as adoption rates for such stoves remain low. Accelerated innovation requires techniques for measuring and verifying such cookstove performance. The overarching goal of the proposed program was to develop a low-cost, wireless instrument to provide a high-resolution profile of the cookstove BC emissions and usage in the field. We proposed transferring the complexity of analysis away from the sampling hardware at the measurement site and to software at a centrally located server to easily analyze data from thousands of sampling instruments. We were able to build a low-cost field-based instrument that produces repeatable, low-cost estimates of cookstove usage, fuel estimates, and emission values with low variability. Emission values from our instrument were consistent with published ranges of emissions for similar stove and fuel types.

  5. Software System for the Calibration of X-Ray Measuring Instruments

    International Nuclear Information System (INIS)

    Gaytan-Gallardo, E.; Tovar-Munoz, V. M.; Cruz-Estrada, P.; Vergara-Martinez, F. J.; Rivero-Gutierrez, T.

    2006-01-01

    A software system that facilities the calibration of X-ray measuring instruments used in medical applications is presented. The Secondary Standard Dosimetry Laboratory (SSDL) of the Nuclear Research National Institute in Mexico (ININ in Spanish), supports activities concerning with ionizing radiations in medical area. One of these activities is the calibration of X-ray measuring instruments, in terms of air kerma or exposure by substitution method in an X-ray beam at a point where the rate has been determined by means of a standard ionization chamber. To automatize this process, a software system has been developed, the calibration system is composed by an X-ray unit, a Dynalizer IIIU X-ray meter by RADCAL, a commercial data acquisition card, the software system and the units to be tested and calibrated. A quality control plan has been applied in the development of the software system, ensuring that quality assurance procedures and standards are being followed

  6. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas)

  7. Optical instrument for measurement of vaginal coating thickness by drug delivery formulations

    International Nuclear Information System (INIS)

    Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.; Couchman, Grace M.; Katz, David F.

    2005-01-01

    An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations - such as gels - applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150 mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150 mm long by 360 deg. azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [∼10 mm diameter; formulations are labeled with 0.1% w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5 mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted

  8. DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

    International Nuclear Information System (INIS)

    Jorgensen, A. M.; Klinglesmith, D. A.; Speights, J.; Clements, A.; Patel, J.

    2009-01-01

    We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The